Engineering Report No. PNPS-CS-12-00001, Rev. 0 Attachment D Page D1 of D127 Attachment D Form 9.7: Area Walk-By Checklists (AWCs)

Engineering Report No. PNPS-CS-12-00001, Rev. 0 Attachment D Page D2 of D127 ATTACHMENT 9.7 AREA WALK-BY CHECKLIST Sheet 1 of 4 Status: YE NF-] U-I Area Walk-By Checklist (AWC)

AWC- 001 Location: Bldg. DG A Floor El. 23 Room, Area, DG A-Entire Room SWEL Components: SWELl-101 Instructions for Completing Checklist This checklist may be used to document the results of the Area Walk-By near one or more SWEL items. The space below each of the following questions may be used to record the results of judgments and findings.

Additional space is provided at the end of this checklist for documenting other comments.

1. Does anchorage of equipment in the area appear to be free of potentially adverse seismic conditions (if visible without necessarily opening cabinets)?
2. Does anchorage of equipment in the area appear to be free of significant degraded conditions?
3. Based on a visual inspection from the floor, do the cable/conduit raceways and HVAC ducting appear to be free of potentially adverse seismic conditions (e.g., condition of supports is adequate and fill conditions of cable trays appear to be inside acceptable limits)?

YE NE! ul-I N/A--

YE NEIl UI-- N/AF-]

Y[K NF1 U-- N/Ai-I No raceways. HVAC noted to be free of potentially adverse seismic conditions.

If the room in which the SWEL item is located is very large (e.g., Turbine Hall), the area selected should be described. This selected area should be based on judgment, e.g., on the order of about 35 feet from the SWEL item.

EN-DC-168 REV 0

Engineering Report No. PNPS-CS-12-00001, Rev. 0 Attachment D Page D3 of D127 ATTACHMENT 9.7 AREA WALK-BY CHECKLIST Sheet 2 of 4 Status: YE NE] uE--

Area Walk-By Checklist (AWC)

AWC- 001 Location: Bldg. DG A Floor El. 23 Room, Area DG A-Entire Room

4. Does it appear that the area is free of potentially adverse seismic YE NE] ULI N/AE-spatial interactions with other equipment in the area (e.g., ceiling tiles and lighting)?

Light on long chain. See SWEL1-101.

5. Does it appear that the area is free of potentially adverse seismic interactions that could cause flooding or spray in the area?

Long run of copper pipe noted. Found to be non-essential instrument air, therefore not a flooding or spray concern. (See attached photo)

YZ N[-] u[-] N/AE1

6. Does it appear that the area is free of potentially adverse seismic interactions that could cause a fire in the area?
7. Does it appear that the area is free of potentially adverse seismic interactions associated with housekeeping practices, storage of portable equipment, and temporary installations (e.g., scaffolding, lead shielding)?

Unsecured broom noted. Light weight of broom poses no adverse seismic condition. Wrench located on floor on west side of equipment.

Wrench is secured with wire therefore it is deemed not to be seismic interaction hazard.

Y[;

NEI urE-N/AE YER NEI U[-] N/AE-EN-DC-168 REV 0

Engineering Report No. PNPS-CS-12-00001, Rev. 0 Attachment D Page D4 of D127 ATTACHMENT 9.7 AREA WALK-BY CHECKLIST Sheet 3 of 4 Status: YZ NI-UL-]

Area Walk-By Checklist (AWC)

AWC- 001 Location: Bldg. DG A Floor El. 23 Room, Area DG A-Entire Room

8. Have you looked for and found no other seismic conditions that could YZ NM UM adversely affect the safety functions of the equipment in the area?

Missing fastener on protective step plate on East side of EDG A (XIO7A) (See attached photo). Three of four fasteners are in place.

The condition is determined to be stable and does not present a seismic interaction hazard. CR-PNP-2012-04367 was written to address this item.

Comments (Additional pages may be added as necessary)

Evaluated by: Gary Sweder Date:

1,-2 o0 /7-Laura Maclay IC-.-

EN-DC-168 REV 0

Engineering Report No. PNPS-CS-12-00001, Rev. 0 Attachment D Page D5 of D127 ATTACHMENT 9.7 AREA WALK-BY CHECKLIST Sheet 4 of 4 Status: Y[

NEI U-I Area Walk-By Checklist (AWC)

AWC- 001 Location: Bldg. DG A Floor El. 23 Room, Area DG A-Entire Room SWEL Components: SWELl-101 PhotoaraDhs EN-DC-168 REV 0

Engineering Report No. PNPS-CS-12-00001, Rev. 0 Attachment D Page D6 of D127 ATTACHMENT 9.7 AREA WALK-BY CHECKLIST Sheet I of 4 Status: YZ NEI UF]

Area Walk-By Checklist (AWC)

AWC- 002 Location: Bldg. DG B Floor El. 23 Room, Areal DG B SWEL Components: SWELl-102 Instructions for Completing Checklist This checklist may be used to document the results of the Area Walk-By near one or more SWEL items. The space below each of the following questions may be used to record the results of judgments and findings.

Additional space is provided at the end of this checklist for documenting other comments.

1. Does anchorage of equipment in the area appear to be free of potentially YZ NE] UE-N/ARl adverse seismic conditions (if visible without necessarily opening cabinets)?

A step plate on the east side of the diesel generator has two fasteners in place and two missing. The connection is still sufficient even with the fasteners missing, as the plate support is welded to the floor; therefore, it is not considered a seismic hazard. CR-PNP-2012-04588 was written and WR 287230 initiated to replace the fasteners. See attached photo.

A missing fastener was found on the cover of C-227. This is not considered a seismic hazard; however, CR-PNP-2012-04589 was written and WR 287230 initiated to replace the fastener. See attached photo.

The steel curb between the DG A and B rooms has four empty bolts holes between the curb and the wall. It is judged that no bolts were ever in place in these locations. In addition, the sealant between the curb and the wall is in good condition. Therefore, it is not considered a seismic hazard.

See photos "PNPS 10-15-12 TI 018" and "PNPS 10-15-12 TI 019" in Share Point.

Several Wej-lt anchors on the north wall do not have full thread engagement. While most have at least 75% engagement, the anchor on the support for 38-HO-107B has two threads disengaged, approx. 50%

engagement. Appendix C of Specification CI 10-ER-Q-E3 states that due to problems with some Wej-lt anchor installations, these anchors were tested and replaced as necessary, and those found acceptable were left in place. Due to the fact that these anchors have previously been evaluated, and that nut engagement does not control the design strength of a Wej-lt anchor bolt, this is not considered a seismic hazard. See photo "PNPS 10-15-12 T1 020" on Share Point.

2. Does anchorage of equipment in the area appear to be free of significant YZ NO UE-N/Al degraded conditions?
3. Based on a visual inspection from the floor, do the cable/conduit YZ NE] UE" N/Ar-raceways and HVAC ducting appear to be free of potentially adverse seismic conditions (e.g., condition of supports is adequate and fill conditions of cable trays appear to be inside acceptable limits)?

If the room in which the SWEL item is located is very large (e.g., Turbine Hall), the area selected should be described. This selected area should be based on judgment, e.g., on the order of about 35 feet from the SWEL item.

EN-DC-168 REV 0

Engineering Report No. PNPS-CS-12-00001, Rev. 0 Attachment D Page D7 of D127 ATTACHMENT 9.7 AREA WALK-BY CHECKLIST Sheet 2 of 4 Status: YZ NEI UM Area Walk-By Checklist (AWC)

AWC- 002 Location: Bldg. DG B Floor El. 23 Room, Area DG B

4. Does it appear that the area is free of potentially adverse seismic spatial interactions with other equipment in the area (e.g., ceiling tiles and lighting)?

Y[E NE] Ur-N/AE--

5. Does it appear that the area is free of potentially adverse seismic interactions that could cause flooding or spray in the area?

There are some threaded joints on fire protection piping in the room; however, the piping is well supported, and so is not considered a seismic interaction concern.

6. Does it appear that the area is free of potentially adverse seismic interactions that could cause a fire in the area?

There is oil accumulating under the lube oil circulation pump at the southwest comer of the diesel generator. A small amount of the oil has accumulated on the floor as well. This is not considered a seismic interaction hazard; however, it was communicated to the system engineer/area owner. This is a previously identified condition with CR-PNP-2011-04187 and WO 00290562 initiated to address the concern.

7. Does it appear that the area is free of potentially adverse seismic interactions associated with housekeeping practices, storage of portable equipment, and temporary installations (e.g., scaffolding, lead shielding)?

YZ NEI ur-N/AL]

YZ NEL U-- N/AL]-

YZ N[-] U[-] N/A[-]

EN-DC-1 68 REV 0

Engineering Report No. PNPS-CS-12-00001, Rev. 0 Attachment D Page D8 of D127 ATrACHMENT 9.7 AREA WALK-BY CHECKLIST Sheet 3 of 4 Status: YE NMJ UMI-Area Walk-By Checklist (AWC)

AWC- 002 Location: Bldg. DG B Floor El. 23 Room, Area DG B

8. Have you looked for and found no other seismic conditions that could YU NEI U[-]

adversely affect the safety functions of the equipment in the area?

There is a long, tight ( < 1/16") vertical crack on the west wall. This is judged to be insignificant and is not considered a seismic hazard. See photo "PNPS 10-15-12 T1 017"on Share Point.

Comments (Additional pages may be added as necessary)

A broken tag for VD-216B as found on the east wall. This was reported to Operations and an ESOMS request has been initiated.

A broken tag on an isolation valve adjacent to 24-A-2 was found on the east wall. This was reported to Operations.

Evaluated by: David Small Date: 10/15/2012 Halie Aroz Lf>J&42I A.

1 0/15/2012 6)

EN-DC-168 REV 0

Engineering Report No. PNPS-CS-12-00001, Rev. 0 Attachment D Page D9 of D127 ATTACHMENT 9.7 AREA WALK-BY CHECKLIST Sheet 4 of 4 Status: YE NE-I Ur-Area Walk-By Checklist (AWC)

AWC- 002 Location: Bldg. DG B Floor El. 23 Room, Area DG B SWEL Components: SWELl-102 Photographs Note: Step plate with two missing bolts.

Note: Missing screw on C-227 cover.

EN-DC-168 REV 0

Engineering Report No. PNPS-CS-12-00001, Rev. 0 Attachment D Page D10 of D127 ATTACHMENT 9.7 AREA WALK-BY CHECKLIST Sheet I of 5 Status: YZ NIF UI-Area Walk-By Checklist (AWC)

AWC- 003 Location: Bldg. AXBAY Floor El. 3 Room, Area' B COMP SWEL Components: SWELl-57, 58, 59, 60 Instructions for Completing Checklist This checklist may be used to document the results of the Area Walk-By near one or more SWEL items. The space below each of the following questions may be used to record the results of judgments and findings.

Additional space is provided at the end of this checklist for documenting other comments.

1. Does anchorage of equipment in the area appear to be free of Y[

N-] UEr] N/A[:]

potentially adverse seismic conditions (if visible without necessarily opening cabinets)?

There is a Y2"-diameter bolt missing on a Unistrut support that is behind, but not clamped to a conduit running from flooding alarm 30-LS-9029.

The span between the adjacent supports in good condition is approximately 9 feet, which is acceptable per Specification C-90-ER-Q-E5. Therefore, this is judged not to be an adverse seismic condition.

See photos "PNPS 10-4-12 TI 029" to "PNPS 10-4-12 TI 033" in Share Point.

2. Does anchorage of equipment in the area appear to be free of Y[

NE] Ur] N/AZ]

significant degraded conditions?

Surface corrosion and some scaling were found on service water inlet valve 29-HO-3837. There is no apparent material loss, so the valve is judged to be acceptable. See photo "PNPS 10-4-12 TI 040" in Share Point.

The base plate of a support for the RBCCW Suction Header piping is slightly lifted on one comer, and some of the grout is chipped off EC-24965 has been issued and will resolve the concern. See photo "PNPS 10-4-12 TI 041" in Share Point.

The grout pad under the pipe support for the P-202D non-safety related drain line is missing some material around its outer perimeter. As the support is beyond the safety class boundary at valve 30-HO-51, and the anchor bolts and majority of the grout are in place and appear sound, this is not considered a seismic hazard. CR-PNP-2012-04832 was written and WR 288870 was initiated to address the concern. See attached photo.

3. Based on a visual inspection from the floor, do the cable/conduit YO NEI U-- N/AZ--

raceways and HVAC ducting appear to be free of potentially adverse seismic conditions (e.g., condition of supports is adequate and fill conditions of cable trays appear to be inside acceptable limits)?

See Marinite board note on SWEL 1-060.

If the room in which the SWEL item is located is very large (e.g., Turbine Hall), the area selected should be described. This selected area should be based on judgment, e.g., on the order of about 35 feet from the SWEL item.

EN-DC-1 68 REV 0

Engineering Report No. PNPS-CS-12-00001, Rev. 0 Attachment D Page Dll of D127 ATTACHMENT 9.7 AREA WALK-BY CHECKLIST Sheet 2 of 4 Status: YM NI UZ-Area Walk-By Checklist (AWC)

AWC- 003 Location: Bldg. AXBAY Floor El. 3 Room, Area B COMP

4. Does it appear that the area is free of potentially adverse seismic spatial interactions with other equipment in the area (e.g., ceiling tiles and lighting)?
5. Does it appear that the area is free of potentially adverse seismic interactions that could cause flooding or spray in the area?
6. Does it appear that the area is free of potentially adverse seismic interactions that could cause a fire in the area?
7. Does it appear that the area is free of potentially adverse seismic interactions associated with housekeeping practices, storage of portable equipment, and temporary installations (e.g., scaffolding, lead shielding)?

There is work in progress on insulation materials on piping around SWEL 1-060, but it does not present a seismic interaction concern.

There is a ladder laying down flat on the floor near SWEL 1-060. Due to its positioning, it does not present a tripping or a seismic interaction concern.

Tools were found in an open section of tube steel from pipe support H-30-1-1224. This is a general plant housekeeping concern, not a seismic interaction hazard, and was reported to Operations for suggested removal. See CR-PNP-2012-04411.

YM NM~ IJEI N/A[D Y[

NEI UD-N/ADI YZ NDI UD1 N/AD-Y[

NDI U[: N/ADl EN-DC-168 REV 0

Engineering Report No. PNPS-CS-12-00001, Rev. 0 Attachment D Page D12 of D127 ATTACHMENT 9.7 AREA WALK-BY CHECKLIST Sheet 3 of 4 Status: YE NE] U-Area Walk-By Checklist (AWC)

AWC- 003 Location: Bldg. AXBAY Floor El. 3 Room, Area B COMP

8. Have you looked for and found no other seismic conditions that could YE NEi ULi adversely affect the safety functions of the equipment in the area?

A chip and a crack were found on the corner of the concrete wall south of the TBCCW heat exchanger. In addition, a crack approx. 1/8" wide was found in the grout pad for a removable steel wall assembly, also south of the TBCCW heat exchanger. The cracks are judged to be superficial and have no impact on the load bearing function of both the concrete wall and the grout pad. CR-PNP-2012-04404 was written to initiate WR 286053 for repairs. See attached photos.

Minor degradation of the coating on RBCCW 16"-HE-30 suction header was observed in the area of the north end of the B-Aux Bay. There is some bubbling of coating and evidence of minor corrosion beginning.

Deficiency Request # 9537 was initiated to track/resolve this issue. See photo "PNPS 10-4-12 T1 043" in Share Point.

Comments (Additional pages may be added as necessary)

Evaluated by-David Sma 010-I Date:

0/0212 Hakie Aroz A

4

,10/0412012 EN-DC-168 REV 0

Engineering Report No. PNPS-CS-12-00001, Rev. 0 Attachment D Page D13 of D127 ATTACHMENT 9.7 AREA WALK-BY CHECKLIST Sheet 4 of 4 Status: YZ NEI UIu Area Walk-By Checklist (AWC)

AWC- 003 Location: Bldg. AXBAY Floor El. 3 Room, Area B COMP SWEL Components: SWELl-57, 58. 59, 60 Photographs Note: Crack in wall south of TBCCW heat exchanger.

Note: Crack in grout pad for removable wall assembly.

EN-DC-1 68 REV 0

Engineering Report No. PNPS-CS-12-00001, Rev. 0 Attachment D Page D14 of D127 ATTACHMENT 9.7 AREA WALK-BY CHECKLIST Sheet 1 of 5 Status: YZ NE] U--

Area Walk-By Checklist (AWC)

AWC- 004 Location: Bldg. RB Floor El. -17.5 Room, Area' HPCI rm SWEL Components: SWELl-12, 35, 39 Instructions for Completing Checklist This checklist may be used to document the results of the Area Walk-By near one or more SWEL items. The space below each of the following questions may be used to record the results of judgments and findings.

Additional space is provided at the end of this checklist for documenting other comments.

1. Does anchorage of equipment in the area appear to be free of potentially adverse seismic conditions (if visible without necessarily opening cabinets)?

The Gaitronics junction box along the East wall is missing two bolts which secure the cover plate to the front of the box. This is not a seismic concern as it currently has two bolts which prevent the cover from falling off, but is good housekeeping practice to ensure all bolts are present. CR-PNP-2012-04591 was written to address the issue.

2. Does anchorage of equipment in the area appear to be free of significant degraded conditions?

Surface corrosion was noted on wall anchor clips supporting instrument air lines in the SE comer of the room, but is acceptable.

3. Based on a visual inspection from the floor, do the cable/conduit raceways and HVAC ducting appear to be free of potentially adverse seismic conditions (e.g., condition of supports is adequate and fill conditions of cable trays appear to be inside acceptable limits)?

YZ Nil U-- N/A[-]

YZ N[-] UEI N/AF-YZ N[-] U[--

N/AD--

I If the room in which the SWEL item is located is very large (e.g., Turbine Hall), the area selected should be described. This selected area should be based on judgment, e.g., on the order of about 35 feet from the SWEL item.

EN-DC-168 REV 0

Engineering Report No. PNPS-CS-12-00001, Rev. 0 Attachment D Page D15 of D127 ATTACHMENT 9.7 AREA WALK-BY CHECKLIST Sheet 2 of 5 Status: YZ NEI U-Area Walk-By Checklist (AWC)

AWC- 004 Location: Bldg. RB Floor El. -17.5 Room, Area HPCI rm

4. Does it appear that the area is free of potentially adverse seismic spatial interactions with other equipment in the area (e.g., ceiling tiles and lighting)?
5. Does it appear that the area is free of potentially adverse seismic interactions that could cause flooding or spray in the area?
6. Does it appear that the area is free of potentially adverse seismic interactions that could cause a fire in the area?
7. Does it appear that the area is free of potentially adverse seismic interactions associated with housekeeping practices, storage of portable equipment, and temporary installations (e.g., scaffolding, lead shielding)?

Non-safety related, HPCI gland seal condenser drain piping is piped through permanent scaffold rack 10-24 in the HPCI quad. Since the piping is not safety related and is well supported, this is not a seismic concern. CR-PNP-2012-04438 was written to address this item.

In addition to the stored scaffold, there are also three ladders in the upright position being stored in the area. If the ladders could be laid on their side, it would be less of potential hazard.

There are also multiple barrels of scaffold clips next to the scaffold cart which have lids lying loosely on one of the barrels. While not a seismic hazard, properly placing the lids on the containers would be good housekeeping practice. It was reported to Operations for suggested action.

Y0 NEI U-- N/AD:]

YE NDI U-- N/AD--

YE NDI UDI N/ADI YE NEI U-- N/AD-EN-DC-168 REV 0

Engineering Report No. PNPS-CS-12-00001, Rev. 0 Attachment D Page D16 of D127 ATrACHMENT 9.7 AREA WALK-BY CHECKLIST Sheet 3 of 5 Status: YZ NF UF Area Walk-By Checklist (AWC)

AWC- 004 Location: Bldg. RB Floor El. -17.5 Room, Area HPCI rm

8. Have you looked for and found no other seismic conditions that could YN NEI UL-adversely affect the safety functions of the equipment in the area?

Two separate temperature sensors, one in the HPCI room and one along the wall next to the stairs coming out of the HPCI quad, are hanging freely from the casing. The sensor numbers are: 24R-TS/D-43-201A, 24R-TS/D-44-201B (Both part of box J 2160) and 24R-TS/D-47-204C, 24R-TS/D-48-204D (from box J 2161). This issue was previously identified and Work Request 260250-01 was written to address it.

Comments (Additional pages may be added as necessary)

Two of the components we inspected are missing tags, pump P203 and turbine X203. In addition, we noted a broken tag near the SE comer of the room, label CK-2301-??? "Torus Suction Line Check Valve". A request was made in eSOM's for new tags.

Temperature switch 23-TS-2300-13 is in contact with the insulation jacket of piping above the switch.

Based on review of Pilgrim Q-List, ENN-MS-S-009-PNP, and HPCI Design Basis Document, SDBD-23, this component does not perform a safety function. The switch only performs an alarm function and does not actively control any equipment or process. The temperature element sits in a well in the lube oil piping and therefore does not constitute part of the lube oil pressure boundary. The pipe in contact with the switch is well supported such that relative movement between the pipe and temperature switch during a seismic event is expected to be small. There is enough flexibility in the switch assembly and pipe insulation to accommodate the movement without adverse effect. It is therefore concluded that this does not represent an adverse seismic interaction.

Evaluated by: Laura Maly A)Ltka 4M

).

Date: 10-15-12 Gary Sweder XCUJA 10-15-12 EN-DC-168 REV 0

Engineering Report No. PNPS-CS-12-00001, Rev. 0 Attachment D Page D17 of D127 ATTACHMENT 9.7 AREA WALK-BY CHECKLIST Sheet 4 of 5 Status: YZ NFI Ur]

Area Walk-By Checklist (AWC)

AWC- 004 Location: Bldg. RB Floor El. -17.5 Room, Area HPCI rm SWEL Components: SWELl-12, 35, 39 Photographs Note: Overall view of room, East wall Note: Overall view of room, West wall EN-DC-1 68 REV 0

Engineering Report No. PNPS-CS-12-O0001, Rev. 0 Attachment D Page D18 of D127 ATTACHMENT 9.7 AREA WALK-BY CHECKLIST Sheet 5 of 5 Status: YM NnI UD Area Walk-By Checklist (AWC)

AWC- 004 Location: Bldg. RB Floor El. -17.5 Room, Area HPCI rm SWEL Components: SWELl-12, 35, 39

-to comments section EN-DC-168 REV 0

Engineering Report No. PNPS-CS-12-00001, Rev. 0 Attachment D Page D19 of D127 ATTACHMENT 9.7 AREA WALK-BY CHECKLIST Sheet I of 5 Status: YZ NE] U--

Area Walk-By Checklist (AWC)

AWC- 005 Location: Bldg. IS Floor El. 25.5 Room, Area, B COMP SWEL Components: SWELl-55, 56 Instructions for Completing Checklist This checklist may be used to document the results of the Area Walk-By near one or more SWEL items. The space below each of the following questions may be used to record the results of judgments and findings.

Additional space is provided at the end of this checklist for documenting other comments.

1. Does anchorage of equipment in the area appear to be free of potentially adverse seismic conditions (if visible without necessarily opening cabinets)?

A missing anchor bolt was found on the base plate of PS-3829A, as well as a missing equipment tag. This missing anchor bolt is demonstrated to be acceptable in the Screening Evaluation Work Sheet (SEWS) for PS-3829A, dated 05/06/1998, under USI A-46. See attached photo and LB Evaluation 001. The equipment tag was reported to Operations, and an ESOMS label request was initiated. See CR-PNP-2012-04411.

2. Does anchorage of equipment in the area appear to be free of significant degraded conditions?

An apparently abandoned, vertically-running conduit was found directly west of P208E, and was not labeled as abandoned. The conduit has a broken/corroded mounting clamp below the grating, as well as ground wire extending from the top of the conduit. The conduit is still securely fastened to the wall with other mounting clamps that are in good condition, so it does not present an adverse seismic interaction concern. CR-PNP-2012-04377 was written to address the issue. See attached photo.

3. Based on a visual inspection from the floor, do the cable/conduit raceways and HVAC ducting appear to be free of potentially adverse seismic conditions (e.g., condition of supports is adequate and fill conditions of cable trays appear to be inside acceptable limits)?

Y[

NEI UW1 N/A[:

YWI NE UWJ N/A[-

YE NWl UWJ N/AEl I If the room in which the SWEL item is located is very large (e.g., Turbine Hall), the area selected should be described. This selected area should be based on judgment, e.g., on the order of about 35 feet from the SWEL item.

EN-DC-168 REV 0

Engineering Report No. PNPS-CS-12-00001, Rev. 0 Attachment D Page D20 of D127 ATTACHMENT 9.7 AREA WALK-BY CHECKLIST Sheet 2 of 5 Status: YZ ND UDJ Area Walk-By Checklist (AWC)

AWC- 005 Location: Bldg. IS Floor El. 25.5 Room, Area B COMP

4. Does it appear that the area is free of potentially adverse seismic spatial interactions with other equipment in the area (e.g., ceiling tiles and lighting)?
5. Does it appear that the area is free of potentially adverse seismic interactions that could cause flooding or spray in the area?
6. Does it appear that the area is free of potentially adverse seismic interactions that could cause a fire in the area?
7. Does it appear that the area is free of potentially adverse seismic interactions associated with housekeeping practices, storage of portable equipment, and temporary installations (e.g., scaffolding, lead shielding)?

Y[

NEJ U[L: N/ADl YE NDJ UiD N/ADl YE NDl UDl N/AD-]

Y[

NDI Ur-D N/AD--

EN-DC-168 REV 0

Engineering Report No. PNPS-CS-12-00001, Rev. 0 Attachment D Page D21 of D127 ATTACHMENT 9.7 AREA WALK-BY CHECKLIST Sheet 3 of 5 Status: YE NEI Ur-Area Walk-By Checklist (AWC)

AWC- 005 Location: Bldg. IS Floor El. 25.5 Room, Area B COMP

8. Have you looked for and found no other seismic conditions that could Y[D NE] U[E]

adversely affect the safety functions of the equipment in the area?

Comments (Additional pages may be added as necessary)

Evaluated by: David Small

~2=z 1#

Date: 1 0/03/2012 Halie Aroz 10/03/2012 EN-DC-168 REV 0

Engineering Report No. PNPS-CS-12-00001, Rev. 0 Attachment D Page D22 of D127 ATTACHMENT 9.7 AREA WALK-BY CHECKLIST Sheet 4 of 5 Status: YZ NE] UI-Area Walk-By Checklist (AWC)

AWC- 005 Location: Bldg. IS Floor El. 25.5 Room, Area B COMP SWEL Components: SWELl-55, 56 Photographs Note: Broken mounting clamp on abandoned conduit.

Note: Ground wire extending from top of conduit.

EN-DC-168 REV 0

Engineering Report No. PNPS-CS-12-00001, Rev. 0 Attachment D Page D23 of D127 ATrACHMENT 9.7 AREA WALK-BY CHECKLIST Sheet 5 of 5 Status: YZ NR UI--

Area Walk-By Checklist (AWC)

AWC- 005 Location: Bldg. IS Floor El. 25.5 Room, Area B COMP SWEL Components: SWELl-55, 56 Note: Missing anchor bolt on PS-3829A base plate.

Note:

EN-DC-1 68 REV 0

Engineering Report No. PNPS-CS-12-00001, Rev. 0 Attachment D Page D24 of D127 ATTACHMENT 9.7 AREA WALK-BY CHECKLIST Sheet 1 of 4 Status: YE NEI ULI Area Walk-By Checklist (AWC)

AWC- 006 Location: Bldg. RB Floor El. 2.75 Room, Area, SW QD-Entire Room SWEL Components: SWELl-52, 53, 65, 66 Instructions for Completing Checklist This checklist may be used to document the results of the Area Walk-By near one or more SWEL items. The space below each of the following questions may be used to record the results of judgments and findings.

Additional space is provided at the end of this checklist for documenting other comments.

1. Does anchorage of equipment in the area appear to be free of potentially adverse seismic conditions (if visible without necessarily opening cabinets)?
2. Does anchorage of equipment in the area appear to be free of significant degraded conditions?
3. Based on a visual inspection from the floor, do the cable/conduit raceways and HVAC ducting appear to be free of potentially adverse seismic conditions (e.g., condition of supports is adequate and fill conditions of cable trays appear to be inside acceptable limits)?

YO Nr-] UE[-

N/AE!-

Y[9 NE! UE-N/A[-]

YE NF-ur--

N/AF-1 I If the room in which the SWEL item is located is very large (e.g., Turbine Hall), the area selected should be described. This selected area should be based on judgment, e.g., on the order of about 35 feet from the SWEL item.

EN-DC-1 68 REV 0

Engineering Report No. PNPS-CS-12-00001, Rev. 0 Attachment D Page D25 of D127 ATTACHMENT 9.7 AREA WALK-BY CHECKLIST Sheet 2 of 4 Status: YE NE] Ur-Area Walk-By Checklist (AWC)

AWC- 006 Location: Bldg. RB Floor El. 2.75 Room, Area SWQD-Entire Room

4. Does it appear that the area is free of potentially adverse seismic spatial interactions with other equipment in the area (e.g., ceiling tiles and lighting)?

Lighting overhead SWEL 1-066 is adequately secured. Blockwall 91.3 and 91.2 in vicinity of SWEL 1-066 is safety related (C950Sh 1, EO)

5. Does it appear that the area is free of potentially adverse seismic interactions that could cause flooding or spray in the area?

Fire pipe overhead uses welded coupling which is found to respond adequately during seismic events.

Y[

NEIl Ui N/A[-!

Y[

NEI U[i N/AZ1

6. Does it appear that the area is free of potentially adverse seismic interactions that could cause a fire in the area?
7. Does it appear that the area is free of potentially adverse seismic interactions associated with housekeeping practices, storage of portable equipment, and temporary installations (e.g., scaffolding, lead shielding)?

A ladder from a Work in Progress site was resting on C2258 equipment. (See SWEL 1-066). The ladder was verified to be relocated in CR-PNP-2012-04379.

Y[

NDJ LiM N/AZl YE NDl UEi N/AZl EN-DC-168 REV 0

Engineering Report No. PNPS-CS-12-00001, Rev. 0 Attachment D Page D26 of D127 ATTACHMENT 9.7 AREA WALK-BY CHECKLIST Sheet 3 of 4 Status: YZI NE UI-Area Walk-By Checklist (AWC)

AWC- 006 Location: Bldg. RB Floor El. 2.75 Room, Area SWQD-Entire Room

8. Have you looked for and found no other seismic conditions that could YO NE-] UM adversely affect the safety functions of the equipment in the area?

Comments (Additional pages may be added as necessary)

A number of housekeeping items were identified during the Area Walk-By. These items are addressed in CR-PNP-2012-04379.

1 1R emergency light was noted to have a non-functioning indicating light. Operations were notified and were previously aware of this item.

Evaluated by: Laura Maclay CLAY'V1 6-I Date: 10-03-12 Gary Sweder JdAh.

,)Su.

Le C

10-03-12 p

EN-DC-1 68 REV 0

Engineering Report No. PNPS-CS-12-00001, Rev. 0 Attachment D Page D27 of D127 ATTACHMENT 9.7 AREA WALK-BY CHECKLIST Sheet 4 of 4 Status: YZ NR UL--

Area Walk-By Checklist (AWC)

AWC- 006 Location: Bldg. RB Floor El. 2.75 Room, Area SW QD-Entire Room SWEL Components: SWELl-52, 53, 66 Note: Tag on floor inside C2256B instrument cage, refer to CR-PNP-2012-04379.

Note: VAC-202B motor data plate has fallen off WR00285935 initiated.

EN-DC-168 REV 0

Engineering Report No. PNPS-CS-12-00001, Rev. 0 Attachment D Page D28 of D127 ATTACHMENT 9.7 AREA WALK-BY CHECKLIST Sheet I of 5 Status: YE NE] UM Area Walk-By Checklist (AWC)

AWC- 007 Location: Bldg. RB Floor El. -17.5 Room, Area, SE QD SWEL Components: SWELl-13, 17. 18 Instructions for Completing Checklist This checklist may be used to document the results of the Area Walk-By near one or more SWEL items. The space below each of the following questions may be used to record the results of judgments and findings.

Additional space is provided at the end of this checklist for documenting other comments.

1. Does anchorage of equipment in the area appear to be free of potentially YO N[i UI-N/AL]

adverse seismic conditions (if visible without necessarily opening cabinets)?

There are several two-bolt base plates with two additional empty holes near the top of the plate. Upon further inspection, it can be seen that the plate is welded to a steel support at the top, and so it is not likely that two bolts are missing. Therefore, this is not considered an adverse seismic condition. See photo "PNPS 10-9-12 TI 023" on Share Point.

There is a base plate at approx. EL 15' on the east wall supporting the stairs that has a bolt hole with no anchor, and the anchor on the opposite side is skewed. It can be seen that ear plates are welded to the top of the main base plate in order to avoid bolting to the masonry block-out, where the original bolt holes were located. The two bolts in the ear plates are in good condition; therefore, this is not considered an adverse seismic condition. See photos "PNPS 10-9-12 TI 024" and "PNPS 10-9-12 T1 025" on Share Point.

There is a base plate at approx. EL 5' on the east wall supporting the stairs that has a nut in place with no anchor. Drawings A-35 and C-356 SH 1 show that anchorage for stair 5 was typically designed to consist of two Y4" diameter expansion anchors. In the field, multiple variations of this anchorage can be found. In general, the as-built anchorage is judged to be acceptable, with welds to embedded plates noted in particular to be more robust than the original design. Also, this particular clip angle has an additional anchor in place when compared to the drawings, and so is not considered a seismic hazard.

See photo "PNPS 10-9-12 TI 031" on Share Point.

There are two base plates at approx. EL 5' and EL 15' on the east wall supporting the stairs that have one bolt hole with no anchor. Upon further inspection, it can be seen that the side of the plate without a bolt is welded to an embedded plate on the concrete. Therefore, this is not considered an adverse seismic condition. See photo "PNPS 10-9-12 TI 032" on Share Point.

The base plate for pipe support H 10-1-46SS along a 20" RHR pump line near MO-1001-43C is on the east wall at approx. EL -3'. It consists of a base plate with two bolts in place and two empty bolt holes, plus an additional plate welded to the original base plate with two bolts. This is shown to be an intentional design per drawing H10-1-46SS, Rev. El. Therefore, the empty bolt holes are not considered an adverse seismic condition. See photo "PNPS 10-9-12 TI 034" on Share Point and LB Evaluation 002.

I If the room in which the SWEL item is located is very large (e.g., Turbine Hall), the area selected should be described. This selected area should be based on judgment, e.g., on the order of about 35 feet from the SWEL item.

EN-DC-168 REV 0

Engineering Report No. PNPS-CS-12-00001, Rev. 0 Attachment D Page D29 of D127 ATTACHMENT 9.7 AREA WALK-BY CHECKLIST Sheet 2 of 5 Status: YE Nr I UD--

Area Walk-By Checklist (AWC)

AWC- 007 Location: Bldg. RB Floor El. -17.5 Room, Area SE QD

2. Does anchorage of equipment in the area appear to be free of significant degraded conditions?

YO NEIl UEI N/AEI

3. Based on a visual inspection from the floor, do the cable/conduit raceways and HVAC ducting appear to be free of potentially adverse seismic conditions (e.g., condition of supports is adequate and fill conditions of cable trays appear to be inside acceptable limits)?

The sheet metal top cover for Cable Tray AYOIP is not attached to the cable tray. The tray is located just outside out the Torus room entrance.

As the cover could potentially fall on safety-related equipment during a seismic event, CR-PNP-2012-04443 was written to address the concern, and WR 286596 has been initiated. See attached photo.

Y[-- NO ULI N/AF-EN-DC-168 REV 0

Engineering Report No. PNPS-CS-12-00001, Rev. 0 Attachment D Page D30 of D127 ATTACHMENT 9.7 AREA WALK-BY CHECKLIST Sheet 3 of 5 Status: YZ NEI U-Area Walk-By Checklist (AWC)

AWC- 007 Location: Bldg. RB Floor El. -17.5 Room, Area SE QD

4. Does it appear that the area is free of potentially adverse seismic spatial interactions with other equipment in the area (e.g., ceiling tiles and lighting)?
5. Does it appear that the area is free of potentially adverse seismic interactions that could cause flooding or spray in the area?
6. Does it appear that the area is free of potentially adverse seismic interactions that could cause a fire in the area?
7. Does it appear that the area is free of potentially adverse seismic interactions associated with housekeeping practices, storage of portable equipment, and temporary installations (e.g., scaffolding, lead shielding)?

A scaffolding stack pin approx. 9" long and a piece of wood approx.

1.5"xl.5"x3' were found lodged between the stair landing support channel and the wall in different locations. Both were found to be completely confined and not in danger of falling out during a seismic event. Therefore, they are judged not to be potentially adverse seismic interactions. See photos "PNPS 10-9-12 TI 026" and "PNPS 10-9-12 TI 042" on Share Point.

A scaffolding pole was found in open tube steel on a pipe support approx. 8 feet west of valve 30-HO-88. This is not considered a potentially adverse seismic interaction; however, Operations was notified for suggested removal of the item, and CR-PNP-2012-04472 was written. See photo "PNPS 10-9-12 T1 039" and on Share Point.

Y[

N[:] U[-] N/Ar"D Y[

NEI] UrI N/AD-YZ NDI UD1 N/A[D-Y[

ND:

UD: N/AD--

EN-DC-168 REV 0

Engineering Report No. PNPS-CS-12-00001, Rev. 0 Attachment D Page D31 of D127 ATTACHMENT 9.7 AREA WALK-BY CHECKLIST Sheet 4 of 5 Status: YZ NF-] Ur Area Walk-By Checklist (AWC)

AWC- 007 Location: Bldg. RB Floor El. -17.5 Room, Area SEQD

8. Have you looked for and found no other seismic conditions that could Y[D NE] Ur-adversely affect the safety functions of the equipment in the area?

There is a long, tight ( < 1/16" wide) crack in the concrete on the east wall running approximately from EL 3' to EL -3'. The crack was discussed with the structural monitoring program engineer and is judged to be insignificant and will not impact the structural integrity of the concrete wall; therefore, this is not a potentially adverse seismic condition. See photo "PNPS 10-9-12 TI 033" in Share Point.

Two conduits, A3068 and A3069, passing through the south wail have degraded concrete at the penetration, approx. Y" in depth. This is determined to be surface degradation only, as no rebar is exposed and the wall appears to be structurally sound over the remaining surface.

Additionally, the degradation does not affect the clearance between the concrete and the conduit, and does not create a pathway through secondary containment. This is judged not to be an adverse seismic condition; however, CR-PNP-2012-04466 was written and WO 00329254 was initiated to repair the degradation. See attached photo.

Comments (Additional pages may be added as necessary)

Evaluated by: David Small 4

`

1-i Date:

10/09/2012 Halie Aroz 10/09/2012' EN-DC-168 REV 0

Engineering Report No. PNPS-CS-12-00001, Rev. 0 Attachment D Page D32 of D127 ATTACHMENT 9.7 AREA WALK-BY CHECKLIST Sheet 5 of 5 Status: YZ NFI U-Area Walk-By Checklist (AWC)

AWC- 007 Location: Bldg. RB Floor El. -17.5 Room, Area SE QD SWEL Components: SWELl-13, 17. 18 Photographs Note: Cable tray AYO1P with unattached steel cover.

Note: Degraded concrete around conduit penetration through south wall.

EN-DC-168 REV 0

Engineering Report No. PNPS-CS-12-00001, Rev. 0 Attachment D Page D33 of D127 ATTACHMENT 9.7 AREA WALK-BY CHECKLIST Sheet I of 5 Status: YZ NF U-Area Walk-By Checklist (AWC)

AWC- 008 Location: Bldg. RB Floor El. -17.5 Room, Areal SWQD SWEL Components: SWELl-26, 27, 28, 29, 30, 31, 32, 33, 36, 37, 40, 41, 42, 43, 44, 45, 47 Instructions for Completing Checklist This checklist may be used to document the results of the Area Walk-By near one or more SWEL items. The space below each of the following questions may be used to record the results of judgments and findings.

Additional space is provided at the end of this checklist for documenting other comments.

1. Does anchorage of equipment in the area appear to be free of potentially adverse seismic conditions (if visible without necessarily opening cabinets)?

A pipe support (H13-1-25) between valves CK-1301-27 & MO-1301-25 was noted to have two of four bolts that were not fully engaged. Per review of design documents from NCR No. 90-30, this condition is acceptable and does not compromise the capacity of the support.

2. Does anchorage of equipment in the area appear to be free of significant degraded conditions?

Safety related piping from MO-1301-61 is supported by unistrut from a floor support. The support was noted to have missing grout beneath the base plate. Review of the support noted that it is designed for vertical forces only, and although grout is missing, the anchor capacity is not compromised. Therefore this is not a seismic concern, but as good practice, CR-PNP-2012-04622 was written to replace the grout to its intended original design.

3. Based on a visual inspection from the floor, do the cable/conduit raceways and HVAC ducting appear to be free of potentially adverse seismic conditions (e.g., condition of supports is adequate and fill conditions of cable trays appear to be inside acceptable limits)?

YE NEI U[E-N/A[J]

YZ Nil U[-7 N/AF-Y[

NM uJ-N/A--

1 If the room in which the SWEL item is located is very large (e.g., Turbine Hall), the area selected should be described. This selected area should be based on judgment, e.g., on the order of about 35 feet from the SWEL item.

EN-DC-168 REV 0

Engineering Report No. PNPS-CS-12-00001, Rev. 0 Attachment D Page D34 of D127 ATTACHMENT 9.7 AREA WALK-BY CHECKLIST Sheet 2 of 5 Status: YE NEI UD Area Walk-By Checklist (AWC)

AWC- 008 Location: Bldg. RB Floor El. -17.5 Room, Area SWQD

4. Does it appear that the area is free of potentially adverse seismic spatial interactions with other equipment in the area (e.g., ceiling tiles and lighting)?

An overhead light located near valve MO-1301-6lis hanging from a bent rigid line which allows it to hang on Gaitronics conduit. While the Gaitronics system is non-safety related, this is not acceptable as the light cover could be knocked off and potentially fall into safety related valves and equipment in the area. CR-PNP-2012-04619 has been written to address the issue.

5. Does it appear that the area is free of potentially adverse seismic interactions that could cause flooding or spray in the area?
6. Does it appear that the area is free of potentially adverse seismic interactions that could cause a fire in the area?
7. Does it appear that the area is free of potentially adverse seismic interactions associated with housekeeping practices, storage of portable equipment, and temporary installations (e.g., scaffolding, lead shielding)?

A fire extinguisher and other testing equipment is properly stored under the stairwell just outside of the room.

YZ NEI UI-N/AZ-]

YZ N[l UI-N/AE--

YZ NI-] ur-N/Ar-YZ NEI Ur-N/AE]

EN-DC-168 REV 0

Engineering Report No. PNPS-CS-12-00001, Rev. 0 Attachment D Page D35 of D127 ATTACHMENT 9.7 AREA WALK-BY CHECKLIST Sheet 3 of 5 Status: YZ NEI U[--

Area Walk-By Checklist (AWC)

AWC- 008 Location: Bldg. RB Floor El. -17.5 Room, Area SWQD

8. Have you looked for and found no other seismic conditions that could Y[

NEI UI-adversely affect the safety functions of the equipment in the area?

A surface crack (<1/16") approximately 3 feet in length was noted on the NE wall of the RCIC quad, but was deemed acceptable by engineering judgment.

Comments (Additional pages may be added as necessary)

Temperature sensors along the wall inside of the entrance to the RCIC quad, are hanging freely from the casing. The sensor numbers are: 24R-TS/D-41-202A, 24R-TS/D-42-202B (Both part of box J 2158.) This issue was previously identified and Work Request 260250-01 was written to address it.

Trash items were noted at the entrance to the room. This is a general plant housekeeping concern and not a seismic interaction hazard. It was reported to Operations for suggested removal.

Evaluated by: Laura Maclav A = A A

  • U &U=.

Date: 10-16-12 Gary Sweder 1_

10-16-12 EN-DC-168 REV 0

Engineering Report No. PNPS-CS-12-00001, Rev. 0 Attachment D Page D36 of D127 ATrACHMENT 9.7 AREA WALK-BY CHECKLIST Sheet 4 of 5 Status: YN NMI-U-

Area Walk-By Checklist (AWC)

AWC- 008 Location: Bldg. RB Floor El. -17.5 Room, Area SWQD SWEL Components: SWELl-26, 27, 28, 29, 30, 31, 32, 33, 36, 37, 40, 41. 42, 43, 44. 57. 47 Photographs Note: Overall view of room Note: Overall view of room EN-DC-168 REV 0

Engineering Report No. PNPS-CS-12-00001, Rev. 0 Attachment D Page D37 of D127 ATTACHMENT 9.7 AREA WALK-BY CHECKLIST Sheet 5 of 5 Status: YN NF] U-Area Walk-By Checklist (AWC)

AWC- 008 Location: Bldg. RB Floor El. -17.5 Room, Area SWQD SWEL Components: SWELl-26. 27, 28, 29, 30. 31, 32. 33. 36, 37, 40. 41, 42, 43. 44. 45, 47 Note: Missing grout under conduit support Note: Bent overhead light against Gaitronics conduit EN-DC-1 68 REV 0

Engineering Report No. PNPS-CS-12-00001, Rev. 0 Attachment D Page D38 of D127 ATTACHMENT 9.7 AREA WALK-BY CHECKLIST Sheet 1 of 3 Status: YZ NE] U-Area Walk-By Checklist (AWC)

AWC- 009 Location: Bldg. RB Floor El. 91.25 Room, Area, 91FT(North)

SWEL Components: SWEL2- 001 Instructions for Completing Checklist This checklist may be used to document the results of the Area Walk-By near one or more SWEL items. The space below each of the following questions may be used to record the results of judgments and findings.

Additional space is provided at the end of this checklist for documenting other comments.

1. Does anchorage of equipment in the area appear to be free of potentially adverse seismic conditions (if visible without necessarily opening cabinets)?
2. Does anchorage of equipment in the area appear to be free of significant degraded conditions?
3. Based on a visual inspection from the floor, do the cable/conduit raceways and HVAC ducting appear to be free of potentially adverse seismic conditions (e.g., condition of supports is adequate and fill conditions of cable trays appear to be inside acceptable limits)?

YN NEI UE-N/AE-Y[

NE-] U[--

N/A--

Y[

NEI UE: N/AE-

' If the room in which the SWEL item is located is very large (e.g., Turbine Hall), the area selected should be described. This selected area should be based on judgment, e.g., on the order of about 35 feet from the SWEL item.

EN-DC-168 REV 0

Engineering Report No. PNPS-CS-12-00001, Rev. 0 Attachment D Page D39 of D127 ATTACHMENT 9.7 AREA WALK-BY CHECKLIST Sheet 2 of 3 Status: YZ NEI UD--

Area Walk-By Checklist (AWC)

AWC- 009 Location: Bldg. RB Floor El. 91.25 Room, Area 91FT (North)

4. Does it appear that the area is free of potentially adverse seismic spatial interactions with other equipment in the area (e.g., ceiling tiles and lighting)?
5. Does it appear that the area is free of potentially adverse seismic interactions that could cause flooding or spray in the area?
6. Does it appear that the area is free of potentially adverse seismic interactions that could cause a fire in the area?
7. Does it appear that the area is free of potentially adverse seismic interactions associated with housekeeping practices, storage of portable equipment, and temporary installations (e.g., scaffolding, lead shielding)?

Portable equipment under stairway was noted to be adequately secured and in compliance with procedure 1.17.1, therefore acceptable.

YE NEI-UE"] N/A[-]

YO NEI ULI N/AE!

YE N[il UI-N/A--

Y[K NEI UiE N/A[--

EN-DC-168 REV 0

Engineering Report No. PNPS-CS-12-00001, Rev. 0 Attachment D Page D40 of D127 A-rrACHMENT 9.7 AREA WALK-BY CHECKLIST Sheet 3 of 3 Status: YM NE1 Ur Area Walk-By Checklist (AWC)

AWC- 009 Location: Bldg. RB Floor El. 91.25 Room, Area 91FT (North)

8. Have you looked for and found no other seismic conditions that could Y;

NEI U[:-

adversely affect the safety functions of the equipment in the area?

Comments (Additional pages may be added as necessary)

Evaluated by: Laura Maclay

'?JJ2 L, -(& J LQ Date: 10-16-12 Gary Sweder W* -& 9 10-16-12 4

EN-DC-168 REV 0

Engineering Report No. PNPS-CS-12-00001, Rev. 0 Attachment D Page D41 of D127 ATTACHMENT 9.7 AREA WALK-BY CHECKLIST Sheet I of 4 Status: YZ NR UD Area Walk-By Checklist (AWC)

AWC- 010 Location: Bldg. RB Floor El. 91.25 Room, Area) 91FT (South)

SWEL Components: SWEL2- 002 Instructions for Completing Checklist This checklist may be used to document the results of the Area Walk-By near one or more SWEL items. The space below each of the following questions may be used to record the results of judgments and findings.

Additional space is provided at the end of this checklist for documenting other comments.

1. Does anchorage of equipment in the area appear to be free of potentially adverse seismic conditions (if visible without necessarily opening cabinets)?
2. Does anchorage of equipment in the area appear to be free of significant degraded conditions?
3. Based on a visual inspection from the floor, do the cable/conduit raceways and HVAC ducting appear to be free of potentially adverse seismic conditions (e.g., condition of supports is adequate and fill conditions of cable trays appear to be inside acceptable limits)?

Y[

NEI ur-N/AD-]

YZ NDI UD-N/AD-Y[

NEI UD-N/AD-I If the room in which the SWEL item is located is very large (e.g., Turbine Hall), the area selected should be described. This selected area should be based on judgment, e.g., on the order of about 35 feet from the SWEL item.

EN-DC-168 REV 0

Engineering Report No. PNPS-CS-12-00001, Rev. 0 Attachment D Page D42 of D127 ATTACHMENT 9.7 AREA WALK-BY CHECKLIST Sheet 2 of 4 Status: YZ N[-- UR-Area Walk-By Checklist (AWC)

AWC- 010 Location: Bldg. RB Floor El. 91.25 Room, Area 91FT(South)

4. Does it appear that the area is free of potentially adverse seismic spatial interactions with other equipment in the area (e.g., ceiling tiles and lighting)?
5. Does it appear that the area is free of potentially adverse seismic interactions that could cause flooding or spray in the area?

Adequate span of fire protection piping and welded connections.

Y[

NF-] U[-

N/ADl YZ NEI U[-

N/AD-

6. Does it appear that the area is free of potentially adverse seismic interactions that could cause a fire in the area?
7. Does it appear that the area is free of potentially adverse seismic interactions associated with housekeeping practices, storage of portable equipment, and temporary installations (e.g., scaffolding, lead shielding)?

YE NDI UD] N/AD Y[

NDI UD-N/AD1 EN-DC-168 REV 0

Engineering Report No. PNPS-CS-12-00001, Rev. 0 Attachment D Page D43 of D127 ATTACHMENT 9.7 AREA WALK-BY CHECKLIST Sheet 3 of 4 Status: Y[

Nil UEl Area Walk-By Checklist (AWC)

AWC- 010 Location: Bldg. RB Floor El. 91.25 Room, Area 91FT (North)

8. Have you looked for and found no other seismic conditions that could YZ N[-] U[LI adversely affect the safety functions of the equipment in the area?

Comments (Additional pages may be added as necessary)

PSV-1 105B was noted to have an acid leak. This item was previously addressed in CR-PNP-201 1-3991. Work order W0289586 has been initiated to fix it.

Efflorescence was noted on the walls. This issue was discussed with the Structural Monitoring Owner and deemed acceptable.

Loose tools were noted to be next to standby liquid control test tank. This is a general plant housekeeping concern and not a seismic interaction hazard. It was reported to Operations for suggested removal.

Evaluated by: Gary Sweder A

)N %.

La Date: 10-16-12 Laura Maclay

?L)Qt 0t) l'*.

ta*

10-16-12 EN-DC-168 REV 0

Engineering Report No. PNPS-CS-12-00001, Rev. 0 Attachment D Page D44 of D127 ATTACHMENT 9.7 AREA WALK-BY CHECKLIST Sheet 4 of 4 Status: YE NR U-Area Walk-By Checklist (AWC)

AWC- 010 Location: Bldg. RB Floor El. 91.75 Room, Area 91FT(South)

SWEL Components: SWEL2- 002 Photographs EN-DC-168 REV 0

Engineering Report No. PNPS-CS-12-00001, Rev. 0 Attachment D Page D45 of D127 ATTACHMENT 9.7 AREA WALK-BY CHECKLIST Sheet 1 of 3 Status: YE NEI UD-]

Area Walk-By Checklist (AWC)

AWC- 011 Location: Bldg. RB Floor El. 23 Room, Area, A VLV SWEL Components: SWELl-15, 16 Instructions for Completing Checklist This checklist may be used to document the results of the Area Walk-By near one or more SWEL items. The space below each of the following questions may be used to record the results of judgments and findings.

Additional space is provided at the end of this checklist for documenting other comments.

1. Does anchorage of equipment in the area appear to be free of potentially adverse seismic conditions (if visible without necessarily opening cabinets)?
2. Does anchorage of equipment in the area appear to be free of significant degraded conditions?
3. Based on a visual inspection from the floor, do the cable/conduit raceways and HVAC ducting appear to be free of potentially adverse seismic conditions (e.g., condition of supports is adequate and fill conditions of cable trays appear to be inside acceptable limits)?

Y[

NDJ UD-N/A[-D Y[

NDJ UD-N/ADJ Y[

NDI U-- N/AD-An abandoned 2" pipe wall penetration appears to have an open crack in the sealant. This is not an adverse seismic affect as the seal does not serve a support function and the pipe is secure. CR-PNP-2012-04661 is written to address this non-seismic item.

'If the room in which the SWEL item is located is very large (e.g., Turbine Hall), the area selected should be described. This selected area should be based on judgment, e.g., on the order of about 35 feet from the SWEL item.

EN-DC-168 REV 0

Engineering Report No. PNPS-CS-12-00001, Rev. 0 Attachment D Page D46 of D127 ATTACHMENT 9.7 AREA WALK-BY CHECKLIST Sheet 2 of 3 Status: YN NEI UD-Area Walk-By Checklist (AWC)

AWC- 011 Location: Bldg. RB Floor El. 23 Room, Area A VLV

4. Does it appear that the area is free of potentially adverse seismic spatial interactions with other equipment in the area (e.g., ceiling tiles and lighting)?
5. Does it appear that the area is free of potentially adverse seismic interactions that could cause flooding or spray in the area?
6. Does it appear that the area is free of potentially adverse seismic interactions that could cause a fire in the area?
7. Does it appear that the area is free of potentially adverse seismic interactions associated with housekeeping practices, storage of portable equipment, and temporary installations (e.g., scaffolding, lead shielding)?

Scaffolding 09-258 is long term scaffold that is evaluated and approved.

The scaffold is not a potentially adverse seismic interaction.

YO NEI u[-] N/Ar-]

YZ ND_1 UD1 N/ADI YZ NDI UDI N/AD--

YZ NDI U[: N/ADl EN-DC-168 REV 0

Engineering Report No. PNPS-CS-12-00001, Rev. 0 Attachment D Page D47 of D127 ATTACHMENT 9.7 AREA WALK-BY CHECKLIST Sheet 3 of 3 Status: YZ NEI UO[I Area Walk-By Checklist (AWC)

AWC- 011 Location: Bldg. RB Floor El. 23 Room, Area A VLV

8. Have you looked for and found no other seismic conditions that could YZ NEi UE]

adversely affect the safety functions of the equipment in the area?

Comments (Additional pages may be added as necessary)

Temperature sensors along the west wall, are hanging freely from the casing. The sensor numbers are: 5-TS-1291-14H (box J258) and 5-TS-1291-14G (box J1504) This issue was previously identified and Work Request 260250-01 was written to address it.

Evaluated by: Gary Sweder Date: 10-17-12 David Small 10-17-12 EN-DC-168 REV 0

Engineering Report No. PNPS-CS-12-00001, Rev. 0 Attachment D Page D48 of D127 ATTACHMENT 9.7 AREA WALK-BY CHECKLIST Sheet 1 of 6 Status: YZ NR U[

Area Walk-By Checklist (AWC)

AWC- 012 Location: Bldg. RB Floor El. 23 Room, Area, WEST-from TIP room comer to South Wall SWEL Components: SWELl- 071, 074 Instructions for Completing Checklist This checklist may be used to document the results of the Area Walk-By near one or more SWEL items. The space below each of the following questions may be used to record the results of judgments and findings.

Additional space is provided at the end of this checklist for documenting other comments.

1. Does anchorage of equipment in the area appear to be free of potentially adverse seismic conditions (if visible without necessarily opening cabinets)?
2. Does anchorage of equipment in the area appear to be free of significant degraded conditions?

The following items are noted but are not considered seismically adverse:

Missing screws on junction box near N2 backup bottle but cover is light and remains secure. CR-PNP-2012-04686 was written to address this item.

Support angle was drilled with new holes due to misaligned initial anchor bolt placement but steel strength not adversely affected.

A base plate near TIP machine has a bolt which is sheared off The base plate is secured by three other well anchored bolts and attached lines are small and well supported above this support. This support is judged to be adequate.

Hairline crack (< 1/16") in wall under base plate is deemed not to adversely affected anchorage.

3. Based on a visual inspection from the floor, do the cable/conduit raceways and HVAC ducting appear to be free of potentially adverse seismic conditions (e.g., condition of supports is adequate and fill conditions of cable trays appear to be inside acceptable limits)?

YN NEIl UE-N/A--

YN NEI U[-] N/A-]

YZ NEl U[i-N/Al]

Area of missing marinite board was noted; however this is not a seismic concern because the board is not in a degraded condition and is not likely to fall.

'If the room in which the SWEL item is located is very large (e.g., Turbine Hall), the area selected should be described. This selected area should be based on judgment, e.g., on the order of about 35 feet from the SWEL item.

EN-DC-168 REV 0

Engineering Report No. PNPS-CS-12-00001, Rev. 0 Attachment D Page D49 of D127 ATTACHMENT 9.7 AREA WALK-BY CHECKLIST Sheet 2 of 6 Status: Y[*

ND--

UD--

Area Walk-By Checklist (AWC)

AWC- 012 Location: Bldg. RB Floor El. 23 Room, Area WEST-from TIP room corner to South Wall

4. Does it appear that the area is free of potentially adverse seismic spatial interactions with other equipment in the area (e.g., ceiling tiles and lighting)?
5. Does it appear that the area is free of potentially adverse seismic interactions that could cause flooding or spray in the area?
6. Does it appear that the area is free of potentially adverse seismic interactions that could cause a fire in the area?
7. Does it appear that the area is free of potentially adverse seismic interactions associated with housekeeping practices, storage of portable equipment, and temporary installations (e.g., scaffolding, lead shielding)?

Ladders staged according to emergency use plan and are acceptable.

Y[

NEI ULI N/A--

Y[

NDI UD1 N/AD-YZ ND-] U[1 N/AD"]

Y[

NEI ULI N/ADl EN-DC-168 REV 0

Engineering Report No. PNPS-CS-12-00001, Rev. 0 Attachment D Page D50 of D127 ATTACHMENT 9.7 AREA WALK-BY CHECKLIST Sheet 3 of 6 Status: YZ NF--i UF-Area Walk-By Checklist (AWC)

AWC- 012 Location: Bldg. RB Floor El. 23 Room, Area WEST-from TIP room comer to South Wall

8. Have you looked for and found no other seismic conditions that could adversely affect the safety functions of the equipment in the area?

YZ NLIUZ1 Comments (Additional pages may be added as necessary)

Evaluated by: Gary Sweder a.A,,M )

4 Date: 10-18-12 Laura Maclay p10-18-12 EN-DC-168 REV 0

Engineering Report No. PNPS-CS-12-00001, Rev. 0 Attachment D Page D51 of D127 ATTACHMENT 9.7 AREA WALK-BY CHECKLIST Sheet 4 of 6 Status: YE NR Ur Area Walk-By Checklist (AWC)

AWC- 012 Location: Bldg. RB Floor El. 23 Room, Area WEST-from TIP room corner to South Wall SWEL Components: SWELh- 071. 074 Photographs Note: Missing screw on junction box. There other side of box is also missing screw.

Note: Bolt holes re-drilled.

EN-DC-168 REV 0

Engineering Report No. PNPS-CS-12-00001, Rev. 0 Attachment D Page D52 of D127 ATTACHMENT 9.7 AREA WALK-BY CHECKLIST Sheet 5 of 6 Status: YM NE U-Area Walk-By Checklist (AWC)

AWC- 012 Location: Bldg. RB Floor El. 23 Room, Area WEST-from TIP room corner to South Wall SWEL Components: SWELl- 071, 074 Note: Support with sheared bolt EN-DC-168 REV 0

Engineering Report No. PNPS-CS-12-00001, Rev. 0 Attachment D Page D53 of D127 ATTACHMENT 9.7 AREA WALK-BY CHECKLIST Sheet 6 of 6 Status: Y[

NEI UI-Area Walk-By Checklist (AWC)

AWC- 012 Location: Bldg. RB Floor El. 23 Room, Area WEST-from TIP room corner to South Wall SWEL Components: SWELl- 071, 074 Note: Missing marinite Note:

EN-DC-168 REV 0

Engineering Report No. PNPS-CS-12-00001, Rev. 0 Attachment D Page D54 of D127 ATTACHMENT 9.7 AREA WALK-BY CHECKLIST Sheet I of 4 Status: YZ NF U--

Area Walk-By Checklist (AWC)

AWC- 014 Location: Bldg. RB Floor El. 23 Room, Area, WEST (btwn TIP room corner and truck lock)

SWEL Components: SWELl- 005, 006, 008, 068, 073 Instructions for Completing Checklist This checklist may be used to document the results of the Area Walk-By near one or more SWEL items. The space below each of the following questions may be used to record the results of judgments and findings.

Additional space is provided at the end of this checklist for documenting other comments.

1. Does anchorage of equipment in the area appear to be free of YZ N[-] Ur] N/AF-potentially adverse seismic conditions (if visible without necessarily opening cabinets)?

The base plates on the west HCU upper gallery support steel frame have several anchor bolts without full thread engagement, but none less than 75% engagement. As the bolts are Wej-lt expansion anchors, the strength of which is not governed by full thread engagement of the nut, the state of these anchors is judged sufficient to develop the full design strength of the anchor. Therefore, it is not considered an adverse seismic condition.

Two LLRT Type B racks were found to have missing bolts. Penetration 52 is missing one of four bolts, and penetration 5 1B is missing two of four bolts. These racks were determined to be non-safety related, and have sufficient anchorage to support the low mass of the piping. Each rack has at least one bolt in both the top and bottom base plates.

Therefore, this is not considered an adverse seismic condition. See photo "PNPS 10-11-12 TI 048" on Share Point.

2. Does anchorage of equipment in the area appear to be free of YZ NEil Ui N/A[--

significant degraded conditions?

3. Based on a visual inspection from the floor, do the cable/conduit Y[

NEr] U-N/AZ' raceways and HVAC ducting appear to be free of potentially adverse seismic conditions (e.g., condition of supports is adequate and fill conditions of cable trays appear to be inside acceptable limits)?

Two light fixtures above the B-18 enclosure are hung by chains that are draped over and offset by a cable tray. The lighting fixture is approx. 30 pounds, which results in a 15-pound load per chain. The worst case angle of the chain is approx. 45 degrees, and would result in a potential horizontal load of approx. 10 pounds on the tray at each point of contact. This load is judged to be insignificant and will not impact the load carrying capacity of the cable tray. Therefore, it is not considered to be an adverse seismic condition. See photo "PNPS 10-11-12 T1 037" on Share Point.

1 If the room in which the SWEL item is located is very large (e.g., Turbine Hall), the area selected should be described. This selected area should be based on judgment, e.g., on the order of about 35 feet from the SWEL item.

EN-DC-168 REV 0

Engineering Report No. PNPS-CS-12-00001, Rev. 0 Attachment D Page D55 of D127 ATTACHMENT 9.7 AREA WALK-BY CHECKLIST Sheet 2 of 4 Status: YZ NRI-U-

Area Walk-By Checklist (AWC)

AWC- 014 Location: Bldg. RB Floor El. 23 Room, Area WEST (btwn TIP room corner and truck lock)

4. Does it appear that the area is free of potentially adverse seismic spatial interactions with other equipment in the area (e.g., ceiling tiles and lighting)?

Radiation blankets shielding the SDIV are hung on open S-hooks.

However, vertical acceleration will be low and there will be no net uplift due to the high mass of the blankets. Horizontal movement will also be minimal due to damping and long pendulum behavior. Therefore, this is not considered to be a potentially adverse seismic interaction. See photo "PNPS 10-11-12 TI 030" on Share Point.

Hose reel RB-07-23 is close enough to panel C-165 to potentially swing into the panel during a seismic event. However, it was discussed with Operations and they determined that there is no sensitive equipment inside the panel. Therefore, this is not a seismic interaction concern.

See photo "PNPS 10-11-12 Ti 051" on Share Point.

The light fixture above the south door of the B-18 enclosure is hung by an open S-hook. As the fixture could potentially fall or swing into equipment in the room during a seismic event, CR-PNP-2012-04513 was written and WR 286905 initiated to address the concern.

5. Does it appear that the area is free of potentially adverse seismic interactions that could cause flooding or spray in the area?
6. Does it appear that the area is free of potentially adverse seismic interactions that could cause a fire in the area?
7. Does it appear that the area is free of potentially adverse seismic interactions associated with housekeeping practices, storage of portable equipment, and temporary installations (e.g., scaffolding, lead shielding)?

An un-tethered wrench and notebooks were found adjacent to HCU 06-27 at the south end of the rack. Other tools are securely hanging on a clip next to the loose wrench, but the wrench does not have a loop for the clip to attach to. This is determined to be deliberate storage of the wrench and notebooks, and is not considered a housekeeping concern.

There is also no sensitive equipment around the items were they to fall during a seismic event, so this is not a seismic interaction concern. See photo "PNPS 10-11-12 TI 011" on Share Point.

A box containing extra charts was found resting on temperature recorder 30R-TR-9013/9014. This is determined to be deliberate storage, and is of low enough mass to not be a seismic interaction concern. See photo "PNPS 10-11-12 TI 044" on Share Point.

A sign for a T-wrench and what looked to be a loose bar were found on the ground. Upon closer inspection, the bar is attached to the T-wrench, which is properly secured to the wall and is not a seismic concern. The loose sign was reported to Operations and an ESOMS request was initiated. See photo "PNPS 10-11-12 T1 041" on Share Point.

Y[I-NM Ur-N/AD-Y[

ND:] Ur-N/AD:]

YN NDl UD-N/AD-YE NiD UD-N/AD-EN-DC-168 REV 0

Engineering Report No. PNPS-CS-12-00001, Rev. 0 Attachment D Page D56 of D127 ATTACHMENT 9.7 AREA WALK-BY CHECKLIST Sheet 3 of 4 Status: YZ NEI ULI Area Walk-By Checklist (AWC)

AWC- 014 Location: Bldg. RB Floor El. 23 Room, Area WEST (btwn TIP room corner and truck lock)

8. Have you looked for and found no other seismic conditions that could YZ NEI UI" adversely affect the safety functions of the equipment in the area?

Fire protection valve 8-1-43 was found to have a rusted operator. While this is not considered a potentially adverse seismic condition, CR-PNP-2012-04511 was written and WR 286893 initiated to address the concern. See attached photo.

Stanchion supports on either side of Reactor Building Heating Valve 24-HO-894 have degraded coating. This is not considered to be a seismic hazard; however, Deficiency Request # 9514 was written to address the concern. See attached photo.

Comments (Additional pages may be added as necessary)

Evaluated by: David Small 4L

/& -

Date: 10/1/2012 Halie Aroz 10/11/2012 EN-DC-168 REV 0

Engineering Report No. PNPS-CS-12-00001, Rev. 0 Attachment D Page D57 of D127 ATTACHMENT 9.7 AREA WALK-BY CHECKLIST Sheet 4 of 4 Status: YZ N[-] UD-]

Area Walk-By Checklist (AWC)

AWC- 014 Location: Bldg. RB Floor El. 23 Room, Area WEST (btwn TIP room comer and truck lock)

SWEL Components: SWELl- 005. 006. 008. 068. 073 Photographs Note: Rusted operator on fire protection valve.

Note: Stanchion with degraded coating.

EN-DC-168 REV 0

Engineering Report No. PNPS-CS-12-00001, Rev. 0 Attachment D Page D58 of D127 ATrACHMENT 9.7 AREA WALK-BY CHECKLIST Sheet I of 4 Status: YZ NEI UE-Area Walk-By Checklist (AWC)

AWC- 015 Location: Bldg. RB Floor El. 23 Room, Area, WEST SWEL Components: SWELl- 080 Instructions for Completing Checklist This checklist may be used to document the results of the Area Walk-By near one or more SWEL items. The space below each of the following questions may be used to record the results of judgments and findings.

Additional space is provided at the end of this checklist for documenting other comments.

1. Does anchorage of equipment in the area appear to be free of potentially adverse seismic conditions (if visible without necessarily opening cabinets)?
2. Does anchorage of equipment in the area appear to be free of significant degraded conditions?
3. Based on a visual inspection from the floor, do the cable/conduit raceways and HVAC ducting appear to be free of potentially adverse seismic conditions (e.g., condition of supports is adequate and fill conditions of cable trays appear to be inside acceptable limits)?

YE NEI UE-'

N/A[:

YE NEI u[-1 N/AE--

YZ N[E UE-N/A--

I If the room in which the SWEL item is located is very large (e.g., Turbine Hall), the area selected should be described. This selected area should be based on judgment, e.g., on the order of about 35 feet from the SWEL item.

EN-DC-168 REV 0

Engineering Report No. PNPS-CS-12-00001, Rev. 0 Attachment D Page D59 of D127 ATTACHMENT 9.7 AREA WALK-BY CHECKLIST Sheet 2 of 4 Status: YE NnI--

U-Area Walk-By Checklist (AWC)

AWC- 015 Location: Bldg. RB Floor El. 23 Room, Area WEST

4. Does it appear that the area is free of potentially adverse seismic spatial interactions with other equipment in the area (e.g., ceiling tiles and lighting)?
5. Does it appear that the area is free of potentially adverse seismic interactions that could cause flooding or spray in the area?
6. Does it appear that the area is free of potentially adverse seismic interactions that could cause a fire in the area?
7. Does it appear that the area is free of potentially adverse seismic interactions associated with housekeeping practices, storage of portable equipment, and temporary installations (e.g., scaffolding, lead shielding)?

YZ NM ULI N/A[]

Y[

NE! UE] N/AF-Z Y[

NEI Ufl N/A["]

YZ NEI UE-N/A--

EN-DC-168 REV 0

Engineering Report No. PNPS-CS-12-00001, Rev. 0 Attachment D Page D60 of D127 ATTACHMENT 9.7 AREA WALK-BY CHECKLIST Sheet 3 of 4 Status: YZ NEI ul-Area Walk-By Checklist (AWC)

AWC- 015 Location: Bldg. RB Floor El. 23 Room, Area WEST

8. Have you looked for and found no other seismic conditions that could YZ NE uE adversely affect the safety functions of the equipment in the area?

Comments (Additional pages may be added as necessary)

Area walk-by visually inspected area around MCC inside of small room behind doors.

Evaluated by: Laura Maclayv t.i f }tCYM Date: 10-18-12 Garv Sweder

_ZýU, 10-18-12 U

EN-DC-168 REV 0

Engineering Report No. PNPS-CS-12-00001, Rev. 0 Attachment D Page D61 of D127 ATTACHMENT 9.7 AREA WALK-BY CHECKLIST Sheet 4 of 4 Status: YE NI-- U-Area Walk-By Checklist (AWC)

AWC- 015 Location: Bldg. RB Floor El. 23 Room, Area WEST SWEL Components: SWELl- 080 Photographs Note: View of area behind MCC Note: View of area behind MCC EN-DC-168 REV 0

Engineering Report No. PNPS-CS-12-00001, Rev. 0 Attachment D Page D62 of D127 ATTACHMENT 9.7 AREA WALK-BY CHECKLIST Sheet I of 4 Status: YE NE] U-Area Walk-By Checklist (AWC)

AWC- 016 Location: Bldg. RB Floor El. 23 Room, Area' EAST (From the North elevator wall to the CRD maintenance shop entrance)

SWEL Components: SWELl- 005. 007. 009, 067, 072 Instructions for Completing Checklist This checklist may be used to document the results of the Area Walk-By near one or more SWEL items. The space below each of the following questions may be used to record the results of judgments and findings.

Additional space is provided at the end of this checklist for documenting other comments.

1. Does anchorage of equipment in the area appear to be free of potentially adverse seismic conditions (if visible without necessarily opening cabinets)?

HCU 26-51 has one 5/8" expansion anchor bolt, different from all the other 1/2" Unistrut bolts. This is not considered to be an adverse seismic condition. See photo "PNPS 10-18-12 T1 026" on Share Point.

The base plates on the east HCU upper gallery support steel frame have several anchor bolts without full thread engagement, but none less than 75% engagement. As the bolts are Wej-lt expansion anchors, the strength of which is not governed by full thread engagement of the nut, the state of these anchors is judged sufficient to develop the full design strength of the anchor. Therefore, it is not considered an adverse seismic condition. See photo "PNPS 10-18-12 T1 041" on Share Point.

The cable way box below panel B-16 9L has 2 missing fasteners and 14 in place. While this is not considered a seismic hazard, CR-PNP-2012-04684 was written and WR 287697 initiated to address the concern. See attached photo.

2. Does anchorage of equipment in the area appear to be free of significant degraded conditions?
3. Based on a visual inspection from the floor, do the cable/conduit raceways and HVAC ducting appear to be free of potentially adverse seismic conditions (e.g., condition of supports is adequate and fill conditions of cable trays appear to be inside acceptable limits)?

YE NI U-I N/A[--

YE NI] UF-N/Ar-Y[

Ni] U[I N/A[l I If the room in which the SWEL item is located is very large (e.g., Turbine Hall), the area selected should be described. This selected area should be based on judgment, e.g., on the order of about 35 feet from the SWEL item.

EN-DC-168 REV 0

Engineering Report No. PNPS-CS-12-00001, Rev. 0 Attachment D Page D63 of D127 ATTACHMENT 9.7 AREA WALK-BY CHECKLIST Sheet 2 of 4 Status: YZ NE-UF Area Walk-By Checklist (AWC)

AWC- 016 Location: Bldg. RB Floor El. 23 Room, Area EAST (From the North elevator wall to the CRD maintenance shon entrance)

4. Does it appear that the area is free of potentially adverse seismic spatial interactions with other equipment in the area (e.g., ceiling tiles and lighting)?

Radiation blankets shielding the SDIV are hung on open S-hooks.

However, vertical acceleration will be low and there will be no net uplift due to the high mass of the blankets. Horizontal movement will also be minimal due to damping and long pendulum behavior. Therefore, this is not considered to be a potentially adverse seismic interaction. See photo "PNPS 10-18-12 T1 040" on Share Point.

Loose lead bricks are stacked adjacent to LLRT Type B Penetration 201B and two electrically traced lines. The LLRT rack is non-safety related, and the piping lines were also determined to be non-safety related using drawings M239 SHI, M1004 SH 305-306, and H-49 051. In addition, the piping was determined to be Sch. 80 stainless steel, and so is judged to be sufficiently robust that the lead bricks do not present a seismic interaction hazard. See photos "PNPS 10-18-12 Ti 029" to "PNPS 10-18-12 TI 031" on Share Point.

5. Does it appear that the area is free of potentially adverse seismic interactions that could cause flooding or spray in the area?
6. Does it appear that the area is free of potentially adverse seismic interactions that could cause a fire in the area?
7. Does it appear that the area is free of potentially adverse seismic interactions associated with housekeeping practices, storage of portable equipment, and temporary installations (e.g., scaffolding, lead shielding)?

A free standing hose rack was found adjacent to panel ET-230. This was reported to Operations and was moved to a safe area in accordance with Procedure 1.17.1, Rev. 12. See photo "PNPS 10 12 TI 028" on Share Point.

A piece of detached insulation was found on the floor behind RM-2000 C-19B. Due to its low mass, this is not a seismic interaction concern; however, it was reported to Operations for suggested removal. See photo "PNPS 10-18-12 T1 038" on Share Point.

Y[

NEI UEJ N/A[-]

Y[

N[E UE-] N/AEr YE NEI UE-N/A[-]

Y[

NEI UEi N/A[:

EN-DC-168 REV 0

Engineering Report No. PNPS-CS-12-00001, Rev. 0 Attachment D Page D64 of D127 ATTACHMENT 9.7 AREA WALK-BY CHECKLIST Sheet 3 of 4 Status: YE NEIl ULI Area Walk-By Checklist (AWC)

AWC- 016 Location: Bldg. RB Floor El. 23 Room, Area EAST(From the North elevator wall to the CRD maintenance shop entrance)

8. Have you looked for and found no other seismic conditions that could Y[] N[] U[]

adversely affect the safety functions of the equipment in the area?

A very tight crack ( < 1/16") in the concrete runs from the base plate of a conduit support behind 43-FT-263-64G. This is judged to be insignificant and is not considered an adverse seismic condition. See photo "PNPS 10-11-12 T1 017" on Share Point.

Comments (Additional pages may be added as necessary)

Evaluated by: David Small Date: 10/18/2012 Halie Aroz

'10/18/2012 EN-DC-168 REV 0

Engineering Report No. PNPS-CS-12-00001, Rev. 0 Attachment D Page D65 of D127 ATTACHMENT 9.7 AREA WALK-BY CHECKLIST Sheet 4 of 4 Status: YZ NE] U--

Area Walk-By Checklist (AWC)

AWC- 016 Location: Bldg. RB Floor El. 23 Room, Area EAST (From the North elevator wall to the CRD maintenance shop entrance)

SWEL Components: SWELl- 005. 007. 009. 067. 072 Photographs Note: Cable way box with missing fasteners.

Note:

EN-DC-168 REV 0

Engineering Report No. PNPS-CS-12-00001, Rev. 0 Attachment D Page D66 of D127 ATTACHMENT 9.7 AREA WALK-BY CHECKLIST Sheet I of 4 Status: YZ NF Ur Area Walk-By Checklist (AWC)

AWC- 017 Location: Bldg. RW Floor El. 23 Room, Area, MG SET SWEL Components: SWELl- 083, 089, 095. 096. 097. 098. 099. 100 Instructions for Completing Checklist This checklist may be used to document the results of the Area Walk-By near one or more SWEL items. The space below each of the following questions may be used to record the results of judgments and findings.

Additional space is provided at the end of this checklist for documenting other comments.

1. Does anchorage of equipment in the area appear to be free of potentially adverse seismic conditions (if visible without necessarily opening cabinets)?

The cover on the gaitronics phone along the South wall of the room is missing one of four fasteners. This is not a seismic hazard as the cover is lightweight and adequately secured with the remaining three fasteners. CR-PNP-2012-04657 was written to address the issue.

2. Does anchorage of equipment in the area appear to be free of significant degraded conditions?
3. Based on a visual inspection from the floor, do the cable/conduit raceways and HVAC ducting appear to be free of potentially adverse seismic conditions (e.g., condition of supports is adequate and fill conditions of cable trays appear to be inside acceptable limits)?

YE NnI U[-] N/An YN N[D UI-N/AD-Y[

N[-] UD-N/AFD 1 If the room in which the SWEL item is located is very large (e.g., Turbine Hall), the area selected should be described. This selected area should be based on judgment, e.g., on the order of about 35 feet from the SWEL item.

EN-DC-1 68 REV 0

Engineering Report No. PNPS-CS-12-00001, Rev. 0 Attachment D Page D67 of D127 ATTACHMENT 9.7 AREA WALK-BY CHECKLIST Sheet 2 of 4 Status: YN NEI UrL Area Walk-By Checklist (AWC)

AWC- 017 Location: Bldg. RW Floor El. 23 Room, Area MG SET

4. Does it appear that the area is free of potentially adverse seismic spatial interactions with other equipment in the area (e.g., ceiling tiles and lighting)?

An overhead light at the entrance to the room is secured by an open s-hook. This is a potential seismic interaction due to safety related panels and equipment below. CR-PNP-2012-04656 has been written to address the issue.

5. Does it appear that the area is free of potentially adverse seismic interactions that could cause flooding or spray in the area?
6. Does it appear that the area is free of potentially adverse seismic interactions that could cause a fire in the area?
7. Does it appear that the area is free of potentially adverse seismic interactions associated with housekeeping practices, storage of portable equipment, and temporary installations (e.g., scaffolding, lead shielding)?

Miscellaneous housekeeping items (tape and small plates) were found during the walkdown and placed next to the entrance to the room.

Operations was notified.

YEll NM UEI N/AE!

Y[K NEI LI UI N/A[:]

YE NR U'- N/AD' YZ NEI U[1 N/ADl EN-DC-168 REV 0

Engineering Report No. PNPS-CS-12-00001, Rev. 0 Attachment D Page D68 of D127 ATTACHMENT 9.7 AREA WALK-BY CHECKLIST Sheet 3 of 4 Status: YZ NE] UrI Area Walk-By Checklist (AWC)

AWC- 017 Location: Bldg. RW Floor El. 23 Room, Area MG SET

8. Have you looked for and found no other seismic conditions that could YE NEI UrI adversely affect the safety functions of the equipment in the area?

There is some minor grout spall at a conduit penetration though the northwest corner floor/wall. This was judged to be insignificant, and is not considered an adverse seismic condition. See photo "PNPS 10 12 T2 066" on Share Point.

Comments (Additional pages may be added as necessary)

Evaluated by: Laura Maclay 6 ui Date: 10-17-12 Halie Aroz

,10-17-12 EN-DC-168 REV 0

Engineering Report No. PNPS-CS-12-00001, Rev. 0 Attachment D Page D69 of D127 ATTACHMENT 9.7 AREA WALK-BY CHECKLIST Sheet 4 of 4 Status: YZ N-- UD--

Area Walk-By Checklist (AWC)

AWC- 017 Location: Bldg. RW Floor El. 23 Room, Area MG SET SWEL Components: SWELl- 083, 089, 095, 096, 097, 098, 099, 100 Photographs Note: Overall view of room from entrance door Note: Open s-hook on overhead light EN-DC-168 REV 0

Engineering Report No. PNPS-CS-12-00001, Rev. 0 Attachment D Page D70 of D127 ATTACHMENT 9.7 AREA WALK-BY CHECKLIST Sheet I of 4 Status: YZ NE] UR-Area Walk-By Checklist (AWC)

AWC- 018 Location: Bldg. RW Floor El. 23 Room, Area' CSR - entire room SWEL Components: SWELl- 077, 084, 090 Instructions for Completing Checklist This checklist may be used to document the results of the Area Walk-By near one or more SWEL items. The space below each of the following questions may be used to record the results of judgments and findings.

Additional space is provided at the end of this checklist for documenting other comments.

1. Does anchorage of equipment in the area appear to be free of potentially adverse seismic conditions (if visible without necessarily opening cabinets)?

Cabinet C2228 A2 has a missing fastener on the front face of the cabinet. Since the vented cover has seven other bolts, this is not a seismic hazard.

Cabinet PCIE-I (B 10) is missing six fasteners on the back side. Due to multiple other fasteners securing the rear panels, this is not a seismic hazard.

CR-PNP-2012-04663 and CR-PNP-2012-04664 were written to address these items.

2. Does anchorage of equipment in the area appear to be free of significant degraded conditions?
3. Based on a visual inspection from the floor, do the cable/conduit raceways and HVAC ducting appear to be free of potentially adverse seismic conditions (e.g., condition of supports is adequate and fill conditions of cable trays appear to be inside acceptable limits)?

YIO NE-U-] N/Ar]

YE NE! ULI N/AZ!

YZ NEI ULE-N/Ar]

IIf the room in which the SWEL item is located is very large (e.g., Turbine Hall), the area selected should be described. This selected area should be based on judgment, e.g., on the order of about 35 feet from the SWEL item.

EN-DC-168 REV 0

Engineering Report No. PNPS-CS-12-00001, Rev. 0 Attachment D Page D71 of D127 ATTACHMENT 9.7 AREA WALK-BY CHECKLIST Sheet 2 of 4 Status: YZ NEI Ur-Area Walk-By Checklist (AWC)

AWC- 018 Location: Bldg. RW Floor El. 23 Room, Area CSR - entire room

4. Does it appear that the area is free of potentially adverse seismic spatial interactions with other equipment in the area (e.g., ceiling tiles and lighting)?
5. Does it appear that the area is free of potentially adverse seismic interactions that could cause flooding or spray in the area?

Fire protection piping is well supported throughout the room. Piping was noted to be near a hanging light, but due to adequate, robust pipe supports near the light, this is acceptable.

6. Does it appear that the area is free of potentially adverse seismic interactions that could cause a fire in the area?
7. Does it appear that the area is free of potentially adverse seismic interactions associated with housekeeping practices, storage of portable equipment, and temporary installations (e.g., scaffolding, lead shielding)?

A piece of wood was found lodged behind the bottom of panel Y-10 on the South wall of the room. Although not a seismic hazard, it does not appear to be part of the design of the cabinet mounting.

Z clips were found lying in a structural steel member that supports a wall penetration on the South wall of the room. These are not seismic hazards, but noted that they are not part of the design, therefore are a housekeeping item.

Operations was notified of the these housekeeping items.

A folding chair and stool are stored along the West wall near J927.

These items are not a seismic hazard and meet the requirements of procedure 1.17. 1.

YN N[-] UED N/AD-Y[

ND:

UEiD N/ADl Y[

NDI UD1 N/AD--

YZ NEI U[D N/AD:]

EN-DC-168 REV 0

Engineering Report No. PNPS-CS-12-00001, Rev. 0 Attachment D Page D72 of D127 ATTACHMENT 9.7 AREA WALK-By CHECKLIST Sheet 3 of 4 Status: YN NEIl ur-Area Walk-By Checklist (AWC)

AWC- 018 Location: Bldg. RW Floor El. 23 Room, Area CSR - entire room

8. Have you looked for and found no other seismic conditions that could YN NF-] UF]

adversely affect the safety functions of the equipment in the area?

A loose/broken tag for conduit penetration 194.601-013-2 was found under cabinet 19L along the West wall. This is a housekeeping item and Operations was notified.

Comments (Additional pages may be added as necessary)

Evaluated by: Laura Maclavy/

Date: 10-17-12 Halie Aroz

(

0-17-12 EN-DC-168 REV 0

Engineering Report No. PNPS-CS-12-00001, Rev. 0 Attachment D Page D73 of D127 AI-rACHMENT 9.7 AREA WALK-BY CHECKLIST Sheet 4 of 4 Status: YE NEI U[I Area Walk-By Checklist (AWC)

AWC- 018 Location: Bldg. RW Floor El. 23 Room, Area CSR - entire room SWEL Components: SWELl- 077, 084, 090 Photographs Note: Overall view of room looking North Note:

EN-DC-168 REV 0