South Texas Project Risk-Informed GSI-191 Evaluation Volume 2: Probabilistic Risk Analysis RI-GSI 191 -V02 Revision I Table B.2-6 Changes to Macro Rules for Event Tree PDSML Event Tree Macro Rule Comment PDSML RCSPHI BI=S*BI=F RCS at high pressure at UTAF. Guaranteed false because pressure is assumed to be < 600 psi in a medium LOCA (BDW)
PDSML RCSPSY BI=S*BI=F RCS at system pressure. Guaranteed false because pressure assumed to be < 600 psi in a MLOCA (BDW)
PDSML SGCOOL BI=S*BI=F Steam Generator cooling. Assumed to be false because MLOCA empties steam generators (BDW)
PDSML RCSPLO VI=F*IMLOCA +ILLOCA RCS at low pressure at UTAF. Pressure assumed to be > 200 psi unless vessel fails (BDW) FOR MLOCAS, YET ALWAYS TRUE FOR LLOCAS PDSML RCSPMD
-RCSPLO RCS at medium pressure at UTAF. Default for MLOCA. Pressure not low added to rule to remove conflict (BOD), NEVER TRUE FOR LLOCA PDSML SEALCOOL
-(BI=S*BI=F)
Dummy rule because pump seal cooling not important in MLOCA. Renamed from LK12F (BDW)
PDSML PORVFL BI=S*BI=F Stuck open PZR PORV not important in MLOCA so guaranteed false. LK13F renamed to PORVFL.
LK15F deleted (BDW)
PDSML RECOOL
((LA=S*RA=S*SI38A=S*-SLBRKA Recirculation cooling using LHSI and RHR HX
+LB=S*RB=S*SI38B=S*-SLBRKB (BDW); 1/3 FOR SUCCESS, ADDED CL INJECTION
+LC=S*RC=S*SI38A=S*-
VALVE AND BREAK LOCATION DEPENDENCIES; SLBRKC)*RX=S)*SUMP=S*FBLK=S*BORON=S AND LOGIC FOR GS1191 FAILURE MODES PDSML CSI SPRYAS+SPRYBS+SPRYCS Containment spray injection success (BDW),
CHANGED TO NEW SPRAY SUCCESS MACROS Page 136 of 256
South Texas Project Risk-Informed GSI-191 Evaluation Volume 2: Probabilistic Risk Analysis RI-GSI191-V02 Revision I Table B.2-6 Changes to Macro Rules for Event Tree PDSML (Continued)
Event Tree Macro Rule Comment PDSML CSR LATESPRYA+LATESPRYB+LATESPRYC Containment spray recirculation success (BDW),
CHANGED TO NEW LATE SPRAY RECIRCULATION MACROS FOR GSI 191 PDSML ISOFAILS CI=F Small containment isolation failure (BDW); LARGE ISOLATION FAILURES ARE MODELED IN CET VIA SF LIB WHICH ENTERS INTO MACRO:= ELARGE PDSML CNTINTB BI=S*BI=F Containment bypass not applicable for MLOCA sequences (BDW)
PDSML SIANY SI38A=S*PA=S*-SLBRKA*(HA=S+LA=S)
SI success using any pump (BDW); CHANGED TO
+SI38B=S*PA=S*-SLBRKB*(HB=S+LB=S)
+
INCLUDE LOGIC FOR CL INJECTION VALVES, SI38C=S*PA=S*-SLBRKC*(HC=S+LC=S)
RWST SUCTION LINES, AND FOR BREAK LOCATION AS WELL AS HPI AND LHSI PUMPS, SPRAY INJECTION REPRESENTED SEPARATELY BY CSI MACRO PDSML SUCC AI=S*-
No core damage REQUIRES SUCCESS OF VI=F*(SUCCHHSI+ILLOCA)*SUCCLHSlR
- ACCUMULATORS, PTS,HPI, & LHSI VIA N2, AND N2=S * (RX=S + RX=F*CP=S*CF=S)*-
THEN LHSI RECIRCULATION WITH COOLING BY SUMP=F*-FBLK=F*-BORON=F RX OR VIA FC ;AND NO GS1191 FAILURE MECHANISMS PDSML SUCCHHSI
((HA=S*S138A=S*PA=S*-SLBRKA*-HHSIA*-
SUCCESSFUL HHSI 1/3 INJECTION TO SlCOMA)+(HB=S*S138B=S*PB=S*-SLBRKB*-
UNBROKEN LOOP, NOT NEEDED FOR HHSIB*-SICOMB)+(HC=S*SI38C=S*PZ=S*-
RECIRCULATION SLBRKC*-HHSIC*-SlCOMC))
PDSML SUCCLHSIR
( (LA=S*S138A=S*PA=S*-SLBRKA*-LHSlA*-
SUCCESFUL LHSI 1/3 TO UNBROKEN LOOP, SICOMA*RA=S)+(LB=S*SI38B=S*PB=S*-
ALSO NEEDED FOR RECIRCULATION SLBRKB*-LHSIB*-
SICOMB*RB=S)+(LC=S*S138C=S*PZ=S*-
SLBRKC*-LHSIC*-SlCOMC*RC=S) )
Page 137 of 256
South Texas Project Risk-Informed GSI-191 Evaluation Volume 2: Probabilistic Risk Analysis RI-GSI 191 -V02 Revision 1 Table B.2-7 Changes to Binning Rules for Event Tree PDSML Sequence Bin Rule Save Comment Cutoff MELT
(-SUCC*-SUMP=F*-FBLK=F*-(BORON=F))
1.OOE-10 MELT SEQUENCES WITHOUT G191 EFFECTS MELTSUMP SUMP=F*-SUCC 1.00E-10 ADDED MELT SEQUENCES DUE TO SUMP STRAINER ISSUES MELTFBLK FBLK=F*-SUCC 1.OOE-10 ADDED MELT SEQUENCES DUE TO FUEL FLOW BLOCKAGE MELTBORON BORON=F*-SUCC 1.OOE-10 ADDED MELT SEQ. DUE TO BORON PRECIP. BUT WITH HLEG=S H3L3S3SUCC LATEHHSI3*LATELHSI3*LATESPRY3*SUCC 1.00E-07 HiLjSk = i HHSI TRAINS S*j LHSI TRAINS S*k SPRAY TRAINS S H3L3S2SUCC LATEHHSI3*LATELHSl3*LATESPRY2*SUCC 1.00E-07 HiLjSk = i HHSI TRAINS S*j LHSI TRAINS S*k SPRAY TRAINS S H3L3SISUCC LATEHHSI3*LATELHSl3*LATESPRYI*SUCC 1.OOE-07 HiLjSk = i HHSI TRAINS S*j LHSI TRAINS S*k SPRAY TRAINS S H3L3SOSUCC LATEHHSI3*LATELHSl3*LATESPRYO*SUCC 1.00E-07 HiLjSk = i HHSI TRAINS S*j LHSI TRAINS S*k SPRAY TRAINS S H3L2S3SUCC LATEHHSl3*LATELHSI2*LATESPRY3*SUCC 1.00E-07 HiLjSk = i HHSI TRAINS S*j LHSI TRAINS S*k SPRAY TRAINS S H3L2S2SUCC LATEHHSI3*LATELHSl2*LATESPRY2*SUCC 1.00E-07 HiLjSk = i HHSI TRAINS S*j LHSI TRAINS S*k SPRAY TRAINS S H3L2SlSUCC LATEHHSI3*LATELHSI2*LATESPRYI*SUCC 1.OOE-07 HiLjSk = i HHSI TRAINS S*j LHSI TRAINS S*k SPRAY TRAINS S H3L2SOSUCC LATEHHSI3*LATELHSl2*LATESPRYO*SUCC 1.00E-07 HiLjSk = i HHSI TRAINS S*j LHSI TRAINS S~k SPRAY TRAINS S H3LIS3SUCC LATEHHSI3*LATELHSII*LATESPRY3*SUCC 1.OOE-07 HiLjSk = i HHSI TRAINS Sij LHSI TRAINS S*k SPRAY TRAINS S H3LIS2SUCC LATEHHSl3*LATELHSII*LATESPRY2*SUCC 1.OOE-07 HiLjSk = i HHSI TRAINS S*j LHSI TRAINS S*k SPRAY TRAINS S H3LISISUCC LATEHHSl3*LATELHSII*LATESPRYI*SUCC 1.00E-07 HiLjSk = i HHSl TRAINS S*j LHSI TRAINS S*k SPRAY I
TRAINS S H3LISOSUCC LATEHHSl3*LATELHSlI*LATESPRYO*SUCC 1.00E-07 HiLjSk = i HHSI TRAINS S*j LHSI TRAINS S*k SPRAY TRAINS S Page 138 of 256
South Texas Project Risk-Informed GSI-191 Evaluation Volume 2: Probabilistic Risk Analysis RI-GSI191-V02 Revision 1 Table B.2-7 Changes to Binning Rules for Event Tree PDSML (Continued)
Sequence Bin Rule Save Comment Cutoff H3LOS3SUCC LATEHHSl3*LATELHSIO*LATESPRY3*SUCC 1.00E-07 HiLjSk = i HHSI TRAINS S*j LHSI TRAINS S*k SPRAY TRAINS S H3LOS2SUCC LATEHHSl3*LATELHSIO*LATESPRY2*SUCC 1.00E-07 HiLjSk = I HHSI TRAINS S*j LHSI TRAINS S*k SPRAY TRAINS S H3LOSlSUCC LATEHHSl3*LATELHSIO*LATESPRYI*SUCC 1.OOE-07 HILjSk = I HHSI TRAINS S*J LHSI TRAINS S*k SPRAY TRAINS S H3LOSOSUCC LATEHHSl3*LATELHSIO*LATESPRYO*SUCC 1.00E-07 HiLjSk = I HHSI TRAINS S*j LHSI TRAINS S*k SPRAY TRAINS S H2L3S3SUCC LATEHHSl2*LATELHSl3*LATESPRY3*SUCC 1.00E-07 HiLjSk = i HHSI TRAINS S*j LHSI TRAINS S*k SPRAY TRAINS S H2L3S2SUCC LATEHHSI2*LATELHSl3*LATESPRY2*SUCC 1.OOE-07 HiLjSk = i HHSI TRAINS S*J LHSI TRAINS S*k SPRAY TRAINS S H2L3SlSUCC LATEHHSI2*LATELHSI3*LATESPRYI*SUCC 1.00E-07 HiLjSk = i HHSI TRAINS S*j LHSI TRAINS S*k SPRAY TRAINS S H2L3SOSUCC LATEHHSl2*LATELHSl3*LATESPRYO*SUCC 1.00E-07 HiLjSk = i HHSI TRAINS Sij LHSl TRAINS S*k SPRAY TRAINS S H2L2S3SUCC LATEHHSl2*LATELHSl2*LATESPRY3*SUCC 1.00E-07 HiLjSk = i HHSI TRAINS S*j LHSI TRAINS S*k SPRAY TRAINS S H2L2S2SUCC LATEHHSl2*LATELHSl2*LATESPRY2*SUCC 1.OOE-07 HiLjSk = i HHSI TRAINS S*j LHSI TRAINS S*k SPRAY TRAINS S H2L2SISUCC LATEHHSI2*LATELHSl2*LATESPRYI*SUCC 1.OOE-07 HiLJSk = i HHSl TRAINS S*j LHSI TRAINS S*k SPRAY TRAINS S H2L2SOSUCC LATEHHSl2*LATELHSl2*LATESPRYO*SUCC 1.OOE-07 HiLjSk = i HHSI TRAINS S*j LHSI TRAINS S*k SPRAY TRAINS S H2LIS3SUCC LATEHHSl2*LATELHSlI*LATESPRY3*SUCC 1.OOE-07 HiLjSk = i HHSI TRAINS S*j LHSI TRAINS S*k SPRAY TRAINS S H2LIS2SUCC LATEHHSl2*LATELHSI1*LATESPRY2*SUCC 1.OOE-07 HiLjSk = i HHSI TRAINS S*j LHSI TRAINS S*k SPRAY I
I_
I TRAINS S H2LISISUCC LATEHHSl2*LATELHSlI*LATESPRYI*SUCC 1.OOE-07 HiLjSk = I HHSI TRAINS S*j LHSI TRAINS S*k SPRAY I
_TRAINS S Page 139 of 256
South Texas Project Risk-Informed GSI-191 Evaluation Volume 2: Probabilistic Risk Analysis RI-GS1191-V02 Revision 1 Table B.2-7 Changes to Binning Rules for Event Tree PDSML (Continued)
Sequence Bin Rule Save Comment Cutoff H2LISOSUCC LATEHHSl2*LATELHSlI*LATESPRYO*SUCC 1.OOE-07 HiLjSk = i HHSI TRAINS S*j LHSI TRAINS S*k SPRAY TRAINS S H2LOS3SUCC LATEHHSl2*LATELHSIO*LATESPRY3*SUCC 1.OOE-07 HiLjSk = i HHSI TRAINS S*j LHSI TRAINS S*k SPRAY TRAINS S H2LOS2SUCC LATEHHSl2*LATELHSIO*LATESPRY2*SUCC 1.OOE-07 HiLjSk = i HHSI TRAINS S*j LHSI TRAINS S*k SPRAY TRAINS S H2LOSlSUCC LATEHHSl2*LATELHSIO*LATESPRYI*SUCC 1.00E-07 HiLjSk = i HHSI TRAINS S*j LHSI TRAINS S*k SPRAY TRAINS S H2LOSOSUCC LATEHHSl2*LATELHSIO*LATESPRYO*SUCC 1.00E-07 HiLjSk = I HHSI TRAINS S*j LHSI TRAINS S*k SPRAY TRAINS S H1L3S3SUCC LATEHHSII*LATELHSl3*LATESPRY3*SUCC 1.00E-07 HiLjSk = i HHSI TRAINS S*j LHSI TRAINS S*k SPRAY TRAINS S HIL3S2SUCC LATEHHSlI*LATELHSl3*LATESPRY2*SUCC 1.00E-07 HiLjSk = i HHSI TRAINS S*j LHSI TRAINS S*k SPRAY TRAINS S HIL3SlSUCC LATEHHSII*LATELHSl3*LATESPRYI*SUCC 1.OOE-07 HiLJSk = i HHSI TRAINS S*j LHSI TRAINS S*k SPRAY TRAINS S HIL3SOSUCC LATEHHSII*LATELHSI3*LATESPRYO*SUCC 1.OOE-07 HiLjSk = i HHSI TRAINS S*j LHSI TRAINS S*k SPRAY TRAINS S HIL2S3SUCC LATEHHSII*LATELHSl2*LATESPRY3*SUCC 1.00E-07 HiLjSk = i HHSI TRAINS S*j LHSI TRAINS S*k SPRAY TRAINS S H1L2S2SUCC LATEHHSI1*LATELHSl2*LATESPRY2*SUCC 1.OOE-07 HiLjSk = i HHSI TRAINS S*j LHSI TRAINS S*k SPRAY TRAINS S HIL2SlSUCC LATEHHSlI*LATELHSl2*LATESPRYI*SUCC 1.OOE-07 HiLjSk = i HHSI TRAINS S*j LHSI TRAINS S*k SPRAY TRAINS S HIL2SOSUCC LATEHHSlI*LATELHSl2*LATESPRYO*SUCC 1.OOE-07 HiLjSk = i HHSI TRAINS S*j LHSI TRAINS S*k SPRAY TRAINS S HILlS3SUCC LATEHHSlI*LATELHSII*LATESPRY3*SUCC 1.OOE-07 HiLjSk = i HHSI TRAINS S*j LHSI TRAINS S*k SPRAY I
I_ TRAINS S HILlS2SUCC LATEHHSII*LATELHSII*LATESPRY2*SUCC 1.OOE-07 HiLjSk = i HHSI TRAINS S*j LHSI TRAINS S*k SPRAY I
_TRAINS S Page 140 of 256
South Texas Project Risk-Informed GSI-191 Evaluation Volume 2: Probabilistic Risk Analysis RI-GSI191-V02 Revision 1 Table B.2-7 Changes to Binning Rules for Event Tree PDSML (Continued)
Sequence Bin Rule Save Comment Cutoff HILISISUCC LATEHHSII*LATELHSII*LATESPRYI*SUCC 1.00E-07 HiLjSk = i HHSI TRAINS S*j LHSI TRAINS S*k SPRAY TRAINS S HILISOSUCC LATEHHSII*LATELHSlI*LATESPRYO*SUCC 1.00E-07 HiLjSk = i HHSI TRAINS S*j LHSI TRAINS S*k SPRAY TRAINS S HILOS3SUCC LATEHHSlI*LATELHSIO*LATESPRY3*SUCC 1.00E-07 HiLjSk = i HHSI TRAINS S*j LHSI TRAINS S*k SPRAY TRAINS S HILOS2SUCC LATEHHSI1*LATELHSIO*LATESPRY2*SUCC 1.00E-07 HiLjSk = i HHSI TRAINS S*j LHSI TRAINS S*k SPRAY TRAINS S H1LOSlSUCC LATEHHSII*LATELHSIO*LATESPRYI*SUCC 1.00E-07 HiLjSk = i HHSI TRAINS S*j LHSI TRAINS S*k SPRAY TRAINS S HILOSOSUCC LATEHHSII*LATELHSIO*LATESPRYO*SUCC 1.OOE-07 HiLjSk = i HHSI TRAINS S*j LHSI TRAINS S*k SPRAY TRAINS S HOL3S3SUCC LATEHHSIO*LATELHSl3*LATESPRY3*SUCC 1.OOE-07 HiLjSk = i HHSI TRAINS S*j LHSI TRAINS S*k SPRAY TRAINS S HOL3S2SUCC LATEHHSIO*LATELHSl3*LATESPRY2*SUCC 1.OOE-07 HiLjSk = i HHSI TRAINS S*j LHSI TRAINS S*k SPRAY TRAINS S HOL3SISUCC LATEHHSIO*LATELHSl3*LATESPRYI*SUCC 1.OOE-07 HiLjSk = i HHSI TRAINS S*j LHSI TRAINS S*k SPRAY TRAINS S HOL3SOSUCC LATEHHSIO*LATELHSl3*LATESPRYO*SUCC 1.00E-07 HiLjSk = i HHSI TRAINS S*j LHSI TRAINS S*k SPRAY TRAINS S HOL2S3SUCC LATEHHSIO*LATELHSl2*LATESPRY3*SUCC 1.OOE-07 HiLjSk = i HHSI TRAINS Sij LHSI TRAINS S*k SPRAY TRAINS S HOL2S2SUCC LATEHHSIO*LATELHSl2*LATESPRY2*SUCC 1.OOE.07 HiLjSk = i HHSI TRAINS S*j LHSI TRAINS S*k SPRAY TRAINS S HOL2SISUCC LATEHHSIO*LATELHSl2*LATESPRYI*SUCC 1.00E-07 HiLjSk = i HHSI TRAINS S*j LHSI TRAINS S*k SPRAY TRAINS S HOL2SOSUCC LATEHHSIO*LATELHSl2*LATESPRYO*SUCC 1.00E-07 HiLjSk = i HHSI TRAINS S*j LHSI TRAINS S*k SPRAY I__I ITRAINS S HOLIS3SUCC LATEHHSIO*LATELHSII*LATESPRY3*SUCC 1.OOE-07 HiLjSk = i HHSI TRAINS S*j LHSI TRAINS S*k SPRAY I_
TRAINS S Page 141 of 256
South Texas Project Risk-Informed GSI-191 Evaluation Volume 2: Probabilistic Risk Analysis RI-GS1191-V02 Revision I Table B.2-7 Changes to Binning Rules for Event Tree PDSML (Continued)
Sequence Bin Rule Save Comment Cutoff HOLlS2SUCC LATEHHSIO*LATELHSI1*LATESPRY2*SUCC 1.OOE-07 HiLjSk = i HHSI TRAINS S*j LHSI TRAINS S*k SPRAY TRAINS S HOLISISUCC LATEHHSIO*LATELHSII*LATESPRYI*SUCC 1.OOE-07 HiLjSk = i HHSI TRAINS S*j LHSI TRAINS S*k SPRAY TRAINS S HOLISOSUCC LATEHHSIO*LATELHSII*LATESPRYO*SUCC 1.OOE-07 HiLjSk = i HHSI TRAINS S*j LHSl TRAINS S*k SPRAY TRAINS S HOLOS3SUCC LATEHHSIO*LATELHSIO*LATESPRY3*SUCC 1.00E-07 HiLjSk = i HHSI TRAINS S*j LHSI TRAINS S*k SPRAY TRAINS S HOLOS2SUCC LATEHHSIO*LATELHSIO*LATESPRY2*SUCC 1.OOE-07 HiLjSk = i HHSI TRAINS S*j LHSI TRAINS S*k SPRAY TRAINS S HOLOSISUCC LATEHHSIO*LATELHSIO*LATESPRYI*SUCC 1.OOE-07 HiLjSk = i HHSI TRAINS S*j LHSI TRAINS S*k SPRAY TRAINS S HOLOSOSUCC LATEHHSIO*LATELHSIO*LATESPRYO*SUCC 1.00E-07 HiLjSk = i HHSI TRAINS S*j LHSI TRAINS S*k SPRAY TRAINS S SUCCESS SUCC 5.OOE+00 MISPLACED SUCCESS SEQUENCES SCPSCISCFS SUCC*CP=S*CI=S*CF=S 1.OOE-07 TEST OF CP,CI,CF FAILURE FREQUENCIES SCPSCISCFF SUCC*CP=S*CI=S*CF=F 1.00E-07 TEST OF CP,CI,CF FAILURE FREQUENCIES SCPSCIFCFS SUCC*CP=S*CI=F*CF=S 1.00E-07 TEST OF CP,CI,CF FAILURE FREQUENCIES SCPSCIFCFF SUCC*CP=S*CI=F*CF=F 1.OOE-07 TEST OF CP,CI,CF FAILURE FREQUENCIES SCPF SUCC*CP=F 1.OOE-07 TEST OF CP,CI,CF FAILURE FREQUENCIES Page 142 of 256
South Texas Project Risk-Informed GSI-191 Evaluation Volume 2: Probabilistic Risk Analysis R1-GSI19I-V02 Revision 1 B.3 Split Fraction Changes Table B.3-1 lists the split fraction names and values used for the event tree quantification. Only the split fractions from top events BORON, FBLK, and SUMP are new. All others are unchanged.
Table B.3-1 Master Frequency File Used for Point Estimate Event Tree Quantification SF Name Top Event SF Value Split Fraction Description ISF AC1A ACl 1.35E-04 CH 1 -ALL SUPPORT INSTO AClAM ACl 2.66E-05 SINGLE TRAIN, CH 1 INV MAINT IV1234 AClY ACl O.OOE+00 GS AC1Z ACi 1.OOE+00 GF AC2A AC2 1.37E-04 CH 2 -ALL SUPPORT INSTN AC2AM1 AC2 1.37E-04 AC1=S, CHi INV MAINT INSTN AC2AM2 AC2 2.57E-05 AC1=S, CH2 INV MAINT IV2134 AC2B AC2 5.01E-04 AC1=F INSTK AC2BM1 AC2 1.36E-04 AC1=F, CHI INV MAINT IV134 AC2BM2 AC2 2.65E-05 AC1=F, CH2 INV MAINT IV234 AC2C AC2 1.37E-04 SINGLE TRAIN INSTN AC2CM AC2 2.57E-05 SINGLE TRAIN, CH2 INV MAINT IV2134 AC2Y AC2 O.OOE+00 GS AC2Z AC2 1.OOE+00 GF AC3A AC3 1.35E-04 CH 3 - ALL SUPPORT INSTM AC3AM1 AC3 1.35E-04 ACO=S, AC2=S, CHi INV MAINT INSTM AC3AM2 AC3 1.35E-04 AC1=S, AC2=S, CH2 INV MAINT INSTM AC3AM3 AC3 1.35E-04 AC1=S, AC2=S, CH3 INV MAINT IV3124 AC3B AC3 4.66E-04 AC1=S, AC2=F INSTH AC3BM1 AC3 4.94E-04 AC1=S, AC2=F, CHi INV MAINT INSTH AC3BM2 AC3 1.37E-04 AC1=S, AC2=F, CH2 INV MAINT IV214 AC3BM3 AC3 2.62E-05 AC1=S, AC2=F, CH3 INV MAINT IV314 Page 143 of 256
South Texas Project Risk-Informed GSI-191 Evaluation Volume 2: Probabilistic Risk Analysis RI-GSI191-V02 Revision 1 Table B.3-1 Master Frequency File Used for Point Estimate Event Tree Quantification (Continued)
SF Name Top Event SF Value Split Fraction Description ISF AC3C AC3 4.77E-04 AC1=F, AC2=S INSTJ AC3CM1 AC3 1.33E-04 AC1=F, AC2=S, CH1 INV MAINT IV124 AC3CM2 AC3 5.05E-04 AC1=F, AC2=S, CH2 INV MAINT INSTJ AC3CM3 AC3 2.57E-05 AC1=F, AC2=S, CH3 INV MAINT IV324 AC3D AC3 5.74E-02 AC1=F, AC2=F INSTE AC3DM1 AC3 4.72E-04 AC1=F, AC2=F, CH1 INV MAINT IV14 AC3DM2 AC3 5.05E-04 AC1=F, AC2=F, CH2 INV MAINT IV24 AC3DM3 AC3 2.65E-05 AC1=F, AC2=F, CH3 INV MAINT IV34 AC3E AC3 1.35E-04 AC1=B, AC2=S INSTM AC3EM2 AC3 1.35E-04 AC1=B, AC2=S, CH2 INV MAINT INSTM AC3EM3 AC3 2.68E-05 AC1=B, AC2=S, CH3 INV MAINT IV3124 AC3F AC3 4.94E-04 AC1=B, AC2=F INSTH AC3FM2 AC3 1.37E-04 AC1=B, AC2=F, CH2 INV MAINT IV214 AC3FM3 AC3 2.62E-05 AC1=B, AC2=F, CH3 INV MAINT IV314 AC3G AC3 1.35E-04 AC1=S, AC2=B INSTM AC3GM1 AC3 1.35E-04 AC1=S, AC2=B, CH1 INV MAINT INSTM AC3GM3 AC3 2.68E-05 AC1=S, AC2=B, CH3 INV MAINT IV3124 AC3H AC3 5.05E-04 AC1=F, AC2=B INSTJ AC3HM1 AC3 1.33E-04 AC1=F, AC2=B, CH1 INV MAINT IV124 AC3HM3 AC3 2.57E-05 AC1=F, AC2=B, CH3 INV MAINT IV324 AC31 AC3 1.35E-04 SINGLE TRAIN INSTM AC31M AC3 2.68E-05 SINGLE TRAIN, CH3 INV MAINT IV3124 AC3Y AC3 O.OOE+00 GS AC3Z AC3 1.OOE+00 GF AC4A AC4 1.35E-04 CH 4 - ALL SUPPORT INSTL AC4AA AC4 1.35E-04 AC1=S, AC2=B, AC3=B INSTL Page 144 of 256
South Texas Project Risk-Informed GSI-191 Evaluation Volume 2: Probabilistic Risk Analysis RI-GSI 19 1 -V02 Revision 1 Table B.3-1 Master Frequency File Used for Point Estimate Event Tree Quantification (Continued)
SF Name Top Event SF Value Split Fraction Description ISF AC4AA1 AC4 1.35E-04 AC1=S, AC2=B, AC3=B, CH1 INV MAINT INSTL AC4AA4 AC4 2.57E-05 AC1=S, AC2=B, AC3=B, CH4 INV MAINT IV4123 AC4AB AC4 5.03E-04 AC1=F, AC2=B, AC3=B INSTI AC4AB1 AC4 1.33E-04 AC1=F, AC2=B, AC3=B, CH1 INV MAINT IV123 AC4AB4 AC4 2.62E-05 AC1=F, AC2=B, AC3=B, CH4 INV MAINT IV423 AC4AC AC4 1.35E-04 SINGLE TRAIN INSTL AC4AC4 AC4 2.57E-05 SINGLE TRAIN, CH4 INV MAINT IV4123 AC4AM1 AC4 1.35E-04 AC1=S, AC2=S, AC3=S, CH1 INV MAINT INSTL AC4AM2 AC4 1.35E-04 AC1=S, AC2=S, AC3=S, CH2 INV MAINT INSTL AC4AM3 AC4 1.35E-04 AC1=S, AC2=S, AC3=S, CH3 INV MAINT INSTL AC4AM4 AC4 2.57E-05 AC1=S, AC2=S, AC3=S, CH4 INV MAINT IV4123 AC4B AC4 4.52E-04 AC1=S, AC2=S, AC3=F INSTF AC4BM1 AC4 4.69E-04 AC1=S, AC2=S, AC3=F, CH1 INV MAINT INSTF AC4BM2 AC4 4.68E-04 AC1=S, AC2=S, AC3=F, CH2 INV MAINT INSTF AC4BM3 AC4 1.33E-04 AC1=S, AC2=S, AC3=F, CH3 INV MAINT IV312 AC4BM4 AC4 2.63E-05 AC1=S, AC2=S, AC3=F, CH4 INV MAINT IV412 AC4C AC4 4.54E-04 AC1=S, AC2=F, AC3=S INSTG AC4CM1 AC4 4.70E-04 AC1=S, AC2=F, AC3=S, CH1 INV MAINT INSTG AC4CM2 AC4 1.38E-04 AC1=S, AC2=F, AC3=S, CH2 INV MAINT IV213 AC4CM3 AC4 4.70E-04 AC1=S, AC2=F, AC3=S, CH3 INV MAINT INSTG AC4CM4 AC4 2.61 E-05 AC1=S, AC2=F, AC3=S, CH4 INV MAINT IV413 AC4D AC4 4.58E-04 AC1=F, AC2=S, AC3=S INSTI AC4DM1 AC4 1.33E-04 AC1=F, AC2=S, AC3=S, CH1 INV MAINT IV123 AC4DM2 AC4 4.74E-04 AC1=F, AC2=S, AC3=S, CH2 INV MAINT INSTI AC4DM3 AC4 4.76E-04 AC1=F, AC2=S, AC3=S, CH3 INV MAINT INSTI AC4DM4 AC4 2.62E-05 AC1=F, AC2=S, AC3=S, CH4 INV MAINT IV423 AC4E AC4 3.38E-02 AC1=S, AC2=F, AC3=F INSTB Page 145 of 256
South Texas Project Risk-Informed GSI-191 Evaluation Volume 2: Probabilistic Risk Analysis RI-GSI191-V02 Revision I Table B.3-1 Master Frequency File Used for Point Estimate Event Tree Quantification (Continued)
SF Name Top Event SF Value Split Fraction Description ISF AC4EM1 AC4 5.48E-02 AC1=S, AC2=F, AC3=F, CH1 INV MAINT INSTB AC4EM2 AC4 4.72E-04 AC1=S, AC2=F, AC3=F, CH2 INV MAINT IV21 AC4EM3 AC4 4.70E-04 AC1=S, AC2=F, AC3=F, CH3 INV MAINT IV31 AC4EM4 AC4 2.71 E-05 AC1=S, AC2=F, AC3=F, CH4 INV MAINT IV41 AC4F AC4 3.71 E-02 ACI =F, AC2=S, AC3=F INSTC AC4FM1 AC4 4.77E-04 AC1=F, AC2=S, AC3=F, CH1 INV MAINT IV12 AC4FM2 AC4 5.78E-02 AC1=F, AC2=S, AC3=F, CH2 INV MAINT INSTC AC4FM3 AC4 4.66E-04 AC1=F, AC2=S, AC3=F, CH3 INV MAINT IV32 AC4FM4 AC4 2.57E-05 AC1=F, AC2=S, AC3=F, CH4 INV MAINT IV42 AC4G AC4 3.42E-02 AC1=F, AC2=F, AC3=S INSTD AC4GM1 AC4 4.62E-04 AC1=F, AC2=F, AC3=S, CH1 INV MAINT IV13 AC4GM2 AC4 4.75E-04 ACI=F, AC2=F, AC3=S, CH2 INV MAINT IV23 AC4GM3 AC4 5.52E-02 AC1=F, AC2=F, AC3=S, CH3 INV MAINT INSTD AC4GM4 AC4 2.62E-05 ACI=F, AC2=F, AC3=S, CH4 INV MAINT IV43 AC4H AC4 4.02E-01 AC1=F, AC2=F, AC3=F INSTA AC4HM1 AC4 5.90E-02 AC1=F, AC2=F, AC3=F, CH1 INV MAINT Ivi AC4HM2 AC4 5.70E-02 AC1=F, AC2=F, AC3=F, CH2 INV MAINT IV2 AC4HM3 AC4 5.92E-02 AC1=F, AC2=F, AC3=F, CH3 INV MAINT IV3 AC4HM4 AC4 2.80E-05 AC1=F, AC2=F, AC3=F, CH4 INV MAINT IV4 AC41 AC4 1.35E-04 AC1=B, AC2=S, AC3=S INSTL AC41M2 AC4 1.35E-04 AC1=B, AC2=S, AC3=S, CH1 INV MAINT INSTL AC41M3 AC4 1.35E-04 AC1=B, AC2=S, AC3=S, CH3 INV MAINT INSTL AC41M4 AC4 2.57E-05 AC1=B, AC2=S, AC3=S, CH4 INV MAINT IV4123 AC4J AC4 4.69E-04 AC1=B, AC2=S, AC3=F INSTF AC4JM2 AC4 4.97E-04 AC1=B, AC2=S, AC3=F, CH2 INV MAINT INSTF AC4JM3 AC4 1.33E-04 AC1=B, AC2=S, AC3=F, CH3 INV MAINT IV312 AC4JM4 AC4 2.63E-05 AC1=B, AC2=S, AC3=F, CH4 INV MAINT IV412 Page 146 of 256
South Texas Project Risk-Informed GSI-191 Evaluation Volume 2: Probabilistic Risk Analysis RI-GSI191-V02 Revision 1 Table B.3-1 Master Frequency File Used for Point Estimate Event Tree Quantification (Continued)
SF Name Top Event SF Value Split Fraction Description ISF AC4K AC4 4.70E-04 AC1=B, AC2=F, AC3=S INSTG AC4KM2 AC4 1.38E-04 AC1=B, AC2=F, AC3=S, CH2 INV MAINT IV213 AC4KM3 AC4 4.97E-04 AC1=B, AC2=F, AC3=S, CH3 INV MAINT INSTG AC4KM4 AC4 2.61 E-05 AC1=B, AC2=F, AC3=S, CH4 INV MAINT IV413 AC4L AC4 5.48E-02 AC1=B, AC2=F, AC3=F INSTB AC4LM2 AC4 5.01 E-04 AC1=B, AC2=F, AC3=F, CH2 INV MAINT IV21 AC4LM3 AC4 4.99E-04 AC1=B, AC2=F, AC3=F, CH3 INV MAINT IV31 AC4LM4 AC4 2.71 E-05 AC1=B, AC2=F, AC3=F, CH4 INV MAINT IV41 AC4M AC4 1.35E-04 AC1=S, AC2=B, AC3=S INSTL AC4MM1 AC4 1.35E-04 AC1=S, AC2=B, AC3=S, CH1 INV MAINT INSTL AC4MM3 AC4 1.35E-04 AC1=S, AC2=B, AC3=S, CH3 INV MAINT INSTL AC4MM4 AC4 2.57E-05 AC1=S, AC2=B, AC3=S, CH4 INV MAINT IV4123 AC4N AC4 4.68E-04 AC1=S, AC2=B, AC3=F INSTF AC4NM1 AC4 4.97E-04 AC1=S, AC2=B, AC3=F, CH1 INV MAINT INSTF AC4NM3 AC4 1.33E-04 AC1=S, AC2=B, AC3=F, CH3 INV MAINT IV312 AC4NM4 AC4 2.63E-05 AC1=S, AC2=B, AC3=F, CH4 INV MAINT IV412 AC40 AC4 4.74E-04 AC1=F, AC2=B, AC3=S INSTI AC4OM1 AC4 1.33E-04 AC1=F, AC2=B, AC3=S, CH1 INV MAINT IV123 AC4OM3 AC4 5.03E-04 AC1=F, AC2=B, AC3=S, CH3 INV MAINT INSTI AC4OM4 AC4 2.62E-05 AC1=F, AC2=B, AC3=S, CH4 INV MAINT IV423 AC4P AC4 5.78E-02 AC1=F, AC2=B, AC3=F INSTC AC4PM1 AC4 5.06E-04 ACI=F, AC2=B, AC3=F, CH1 INV MAINT IV12 AC4PM3 AC4 4.96E-04 AC1=F, AC2=B, AC3=F, CH3 INV MAINT IV32 AC4PM4 AC4 2.58E-05 AC1=F, AC2=B, AC3=F, CH4 INV MAINT IV42 AC4Q AC4 1.35E-04 AC1=S, AC2=S, AC3=B INSTL AC4QM1 AC4 1.35E-04 AC1=S, AC2=S, AC3=B, CH1 INV MAINT INSTL AC4QM2 AC4 1.35E-04 AC1=S, AC2=S, AC3=B, CH2 INV MAINT INSTL Page 147 of 256
South Texas Project Risk-Informed GSI-191 Evaluation Volume 2: Probabilistic Risk Analysis RI-GS119 l-V02 Revision I Table B.3-1 Master Frequency File Used for Point Estimate Event Tree Quantification (Continued)
SF Name Top Event SF Value Split Fraction Description ISF AC4QM4 AC4 2.57E-05 AC1=S, AC2=S, AC3=B, CH4 INV MAINT IV4123 AC4R AC4 4.70E-04 AC1=S, AC2=F, AC3=B INSTG AC4RM1 AC4 4.97E-04 AC1=S, AC2=F, AC3=B, CHI INV MAINT INSTG AC4RM2 AC4 1.38E-04 AC1=S, AC2=F, AC3=B, CH2 INV MAINT IV213 AC4RM4 AC4 2.61E-05 AC1=S, AC2=F, AC3=B, CH4 INV MAINT IV413 AC4S AC4 4.76E-04 AC1=F, AC2=S, AC3=B INSTI AC4SM1 AC4 1.33E-04 AC1=F, AC2=S, AC3=B, CHI INV MAINT IV123 AC4SM2 AC4 5.03E-04 AC1=F, AC2=S, AC3=B, CH2 INV MAINT INSTI AC4SM4 AC4 2.62E-05 AC1=F, AC2=S, AC3=B, CH4 INV MAINT IV423 AC4T AC4 5.52E-02 AC1=F, AC2=F, AC3=B INSTD AC4TM1 AC4 4.90E-04 AC1=F, AC2=F, AC3=B, CHi INV MAINT IV13 AC4TM2 AC4 5.04E-04 AC1=F, AC2=F, AC3=B, CH2 INV MAINT IV23 AC4TM4 AC4 2.63E-05 ACI=F, AC2=F, AC3=B, CH4 INV MAINT IV43 AC4U AC4 1.35E-04 AC1=B, AC2=B, AC3=S INSTL AC4UM3 AC4 1.35E-04 AC1=B, AC2=B, AC3=S, CH3 INV MAINT INSTL AC4UM4 AC4 2.57E-05 AC1=B, AC2=B, AC3=S, CH4 INV MAINT IV4123 AC4V AC4 4.97E-04 AC1=B, AC2=B, AC3=F INSTF AC4VM3 AC4 1.33E-04 AC1 =B, AC2=B, AC3=F, CH3 INV MAINT IV312 AC4VM4 AC4 2.63E-05 AC1=B, AC2=B, AC3=F, CH4 INV MAINT IV412 AC4W AC4 1.35E-04 AC1=B, AC2=S, AC3=B INSTL AC4WM2 AC4 1.35E-04 AC1 =B, AC2=S, AC3=B, CH2 INV MAINT INSTL AC4WM4 AC4 2.57E-05 AC1=B, AC2=S, AC3=B, CH4 INV MAINT IV4123 AC4X AC4 4.97E-04 AC1=B, AC2=F, AC3=B INSTG AC4XM2 AC4 1.38E-04 AC1=B, AC2=F, AC3=B, CH2 INV MAINT IV213 AC4XM4 AC4 2.61 E-05 AC1=B, AC2=F, AC3=B, CH4 INV MAINT IV413 AC4Y AC4 O.OOE+00 GS AC4Z AC4 1.OOE+00 GF Page 148 of 256
South Texas Project Risk-Informed GSI-191 Evaluation Volume 2: Probabilistic Risk Analysis RI-GSI191-V02 Revision 1 Table B.3-1 Master Frequency File Used for Point Estimate Event Tree Quantification (Continued)
SF Name Top Event SF Value Split Fraction Description ISF AF1A AFWS 3.74E-03 AFWP 11 AF B AFWS 3.76E-03 AFWP 12 AFPC AFWS 3.73E-03 AFWP 13 AF1D AFWS 1.12E-02 AFWP 14 AF2AB AFWS 6.55E-05 AFWP 11 AND 12 AF2AC AFWS 6.47E-05 AFWP 11 AND 13 AF2AD AFWS 5.42E-05 AFWP 11 AND 14 AF2BC AFWS 6.54E-05 AFWP 12 AND 13 AF2BD AFWS 5.42E-05 AFWP 12 AND 14 AF2CD AFWS 5.48E-05 AFWP 13 AND 14 AF3ABC AFWS 1.70E-05 AFWP 11, 12, AND 13 AF3ABD AFWS 4.07E-06 AFWP 11, 12, AND 14 AF3ACD AFWS 3.93E-06 AFWP 11, 13, AND 14 AF3BCD AFWS 4.07E-06 AFWP 12, 13, AND 14 AF4 AFWS 1.99E-06 ALL AFWP AFAA AFA 3.74E-03 AFA AFIA AFAY AFA O.OOE+00 GS AFAZ AFA 1.OOE+00 GF AFBA AFB 3.71 E-03 AFB, A=S AFI B AFBB AFB 1.75E-02 AFB, A=F AF2AB AFBC AFB 3.76E-03 AFB, A=B AF1B AFBY AFB O.OOE+00 GS AFBZ AFB 1.OOE+00 GF AFCA AFC 3.64E-03 AFC, A=S B=S AFlC AFCB AFC 1.31E-02 AFC, A=S B=F AF2BC AFCC AFC 1.30E-02 AFC, A=F B=S AF2AC AFCD AFC 2.60E-01 AFC, A=F B=F AF3ABC Page 149 of 256
South Texas Project Risk-Informed GSI-191 Evaluation Volume 2: Probabilistic Risk Analysis RI-GSII91-V02 Revision 1 Table B.3-1 Master Frequency File Used for Point Estimate Event Tree Quantification (Continued)
SF Name Top Event SF Value Split Fraction Description ISF AFCE AFC 3.68E-03 AFC, A=B B=S AFlC AFCF AFC 1.74E-02 AFC, A=B B=F AF2BC AFCG AFC 3.68E-03 AFC, A=S B=B AFiC AFCH AFC 1.73E-02 AFC, A=F B=B AF2AC AFCl AFC 3.73E-03 AFC, A=B B=B AFiC AFCY AFC O.OOE+00 GS AFCZ AFC 1.OOE+00 GF AFDA AFD 1.1 2E-02 AFD A=S B=S C=S AF1 D AFDAA AFD 1.1 2E-02 AFD A=S B=B C=B AF1 D AFDAB AFD 1.45E-02 AFD A=F B=B C=B AF2AD AFDAC AFD 1.12E-02 AFD A=B B=B C=B AF1D AFDB AFD 1.35E-02 AFD A=S B=S C=F AF2CD AFDC AFD 1.32E-02 AFD A=S B=F C=S AF2BD AFDD AFD 4.29E-02 AFD A=S B=F C=F AF3BCD AFDE AFD 1.33E-02 AFD A=F B=S C=S AF2AD AFDF AFD 4.07E-02 AFD A=F B=S C=F AF2AD AFDG AFD 4.29E-02 AFD A=F B=F C=S AF3ABD AFDH AFD 1.17E-01 AFD A=F B=F C=F AF4 AFDI AFD 1.12E-02 AFD A=B B=S C=S AF1D AFDJ AFD 1.38E-02 AFD A=B B=S C=F AF2CD AFDK AFD 1.36E-02 AFD A=B B=F C=S AF2BD AFDL AFD 6.22E-02 AFD A=B B=F C=F AF3BCD AFDM AFD 1.12E-02 AFD A=S B=B C=S AF1D AFDN AFD 1.39E-02 AFD A=S B=B C=F AF2CD AFDO AFD 1.37E-02 AFD A=F B=B C=S AF2AD AFDP AFD 6.08E-02 AFD A=F B=B C=F AF3ACD AFDQ AFD 1.12E-02 AFD A=S B=S C=B AF1D Page 150 of 256
South Texas Project Risk-Informed GSI-191 Evaluation Volume 2: Probabilistic Risk Analysis RI-GS1191-V02 Revision 1 Table B.3-1 Master Frequency File Used for Point Estimate Event Tree Quantification (Continued)
SF Name Top Event SF Value Split Fraction Description ISF AFDR AFD 1.36E-02 AFD A=S B=F C=B AF2BD AFDS AFD 1.36E-02 AFD A=F B=S C=B AF2AD AFDT AFD 6.21 E-02 AFD A=F B=F C=B AF3ABD AFDU AFD 1.12E-02 AFD A=B B=B C=S AF1 D AFDV AFD 1.47E-02 AFD A=B B=B C=F AF2CD AFDW AFD 1.12E-02 AFD A=B B=S C=B AF1D AFDX AFD 1.44E-02 AFD A=B B=F C=B AF2BD AFDY AFD O.OOE+00 GS AFDZ AFD 1.OOE+00 GF AILL Al 5.OOE-07 ACCUMULATORS A, B, C FOR LLOCA AILLAB Al 8.74E-04 ACCUMULATORS A, B FOR LLOCA AILLAC Al 8.63E-04 ACCUMULATORS A, C FOR LLOCA AILLBC Al 8.69E-04 ACCUMULATORS B, C FOR LLOCA AILLY Al O.OOE+00 GS AILLZ Al 1.OOE+00 GF AIML Al 7.58E-1 1 ACCUMULATOR A, B, C FOR MLOCA AIMLA Al 4.36E-04 ACCUMULATOR A FOR MLOCA AIMLAB Al 1.68E-07 ACCUMULATOR A, B FOR MLOCA AIMLAC Al 1.64E-07 ACCUMULATOR A, C FOR MLOCA AIMLB Al 4.39E-04 ACCUMULATOR B FOR MLOCA AIMLBC Al 1.66E-07 ACCUMULATOR B, C FOR MLOCA AIMLC Al 4.33E-04 ACCUMULATOR C FOR MLOCA AIMLY Al O.OOE+00 GS AIMLZ Al 1.OOE+00 GF AMA AM 1.OOE-02 AMSAC FAILURE PROBABILITY AMY AM O.OOE+00 GS AMZ AM 1.OOE+00 GF Page 151 of 256
South Texas Project Risk-Informed GSI-191 Evaluation Volume 2: Probabilistic Risk Analysis RI-GSI 19 1 -V02 Revision 1 Table B.3-1 Master Frequency File Used for Point Estimate Event Tree Quantification (Continued)
SF Name Top Event SF Value Split Fraction Description ISF APH AP 1.OOE-04 RCS PRESSURE > 200 PSIA APL AP 1.OOE-03 RCS PRESSURE < 200 PSIA BFA BF 7.13E-05 FAILURE OF 13.8KV BUS 1F TO ENERGIZE E1A BFY BF 0.OOE+00 GS BFZ BF 1.OOE+00 GF BGA BG 5.77E-05 FAILURE OF 13.8KV BUS 1G TO ENERGIZE EIB BGY BG 0.OOE+00 GS BGZ BG 1.OOE+00 GF BHA BH 7.07E-05 FAILURE OF 13.8KV BUS 1H TO ENERGIZE ElC BHY BH 0.OOE+00 GS BHZ BH 1.OOE+00 GF BIY BI 0.OOE+00 PDS BINNING BLLIF BORON 2.56E-01 LLOCA, PUMP STATE 1, HLEG=F, WITH GSI-191 ISSUES BLLIS BORON 6.93E-04 LLOCA, PUMP STATE 1, HLEG=S, WITH GSI-191 ISSUES BLL22F BORON 2.56E-01 LLOCA, PUMP STATE 22, HLEG=F,WITH GSI-191 ISSUES BLL22S BORON 7.50E-05 LLOCA, PUMP STATE 22, HLEG=S, WITH GSI-191 ISSUES BLL26F BORON 2.56E-01 LLOCA, PUMP STATE 26, HLEG=F, WITH GSI-191 ISSUES BLL26S BORON 6.11E-05 LLOCA,, PUMP STATE 26, HLEG=S, WITH GSI-191 ISSUES BLL43F BORON 2.56E-01 LLOCA, PUMP STATE 43, HLEG=F, WITH GSI-191 ISSUES BLL43S BORON 3.42E-06 LLOCA, PUMP STATE 43, HLEG=S, WITH GSI-191 ISSUES BLL9F BORON 2.57E-01 LLOCA, PUMP STATE 9, HLEG=F, WITH GSI-191 ISSUES Page 152 of 256
South Texas Project Risk-Informed GSI-191 Evaluation Volume 2: Probabilistic Risk Analysis RI-GSI 1 91-V02 Revision 1 Table B.3-1 Master Frequency File Used for Point Estimate Event Tree Quantification (Continued)
SF Name Top Event SF Value Split Fraction Description ISF BLL9S BORON 1.82E-03 LLOCA, PUMP STATE 9, HLEG=S, WITH GSI-191 ISSUES BLLGF BORON 2.56E-01 LLOCA, DEAFULT PUMP STATES, WITH GSI-191 ISSUES BML1F BORON 3.81E-01 MLOCA, PUMP STATE 1, HLEG=F, WITH GSI-191 ISSUES BMLIS BORON O.OOE+00 MLOCA, PUMP STATE 1, HLEG=S, WITH GSI-191 ISSUES BML22F BORON 3.81 E-01 MLOCA, PUMP STATE 22, HLEG=F, WITH GSI-191 ISSUES BML22S BORON 0.OOE+00 MLOCA, PUMP STATE 22, HLEG=S, WITH GSI-191 ISSUES BML26F BORON 3.81 E-01 MLOCA, PUMP STATE 26, HLEG=F, WITH GSI-191 ISSUES BML26S BORON 0.OOE+00 MLOCA, PUMP STATE 26, HLEG=S, WITH GSI-191 ISSUES BML43F BORON 3.81 E-01 MLOCA, PUMP STATE 43, HLEG=F, WITH GSI-191 ISSUES BML43S BORON 0.OOE+00 MLOCA, PUMP STATE 43, HLEG=S, WITH GSI-191 ISSUES BML9F BORON 3.81E-01 MLOCA, PUMP STATE 9, HLEG=F, WITH GSI-191 ISSUES BML9S BORON 0.OOE+00 MLOCA, PUMP STATE 9, HLEG=S, WITH GSI-191 ISSUES BMLGF BORON 3.81 E-01 MLOCA, DEFAULT PUMP STATES, WITH GSI-191 ISSUES BORLL BORON 2.56E-01 LLOCA CL FRACTION GIVEN HLEG=F, NO GSI 1091 ISSUES BORML BORON 3.81 E-01 MLOCA CL FRACTION GIVEN HLEG=F, NO GSI ISSUES BORONY BORON 0.OOE+00 HLEG=S NO GIS-191 PHENOMENA BORONZ BORON 1.00E+00 NOT USED BRKSO BRKS O.OOE+00 USED TO ZERO OUT APPROPRIATE STEAM I LINE BREAK BRANCHES Page 153 of 256
South Texas Project Risk-Informed GS1-191 Evaluation Volume 2: Probabilistic Risk Analysis RI-GSI 191 -V02 Revision 1 Table B.3-1 Master Frequency File Used for Point Estimate Event Tree Quantification (Continued)
SF Name Top Event SF Value Split Fraction Description ISF BRKSA BRKS 2.50E-01 BREAK STEAM LINE A BRKSB BRKS 2.50E-01 BREAK STEAM LINE B BRKSC BRKS 2.50E-01 BREAK STEAM LINE C BRKSD BRKS 2.50E-01 BREAK STEAM LINE D BRKSE BRKS 1.OOE+00 NO STEAM LINE BREAK BYA BY 1.OOE+00 LETDOWN V SEQUENCE OR UNISOLATED SGTR BYB BY 0.OOE+00 NO CONTAINMENT BYPASS ClA Cl 0.OOE+00 CONTAINMENT ISOLATED PRIOR TO VESSEL BREACH C1B C1 1.OOE+00 CONTAINMENT NOT ISOLATED AT UTAF C2A C2 1.OOE-05 RCS PRESSURE < 200 PSIA AT VESSEL BREACH C2B C2 1.00E-05 NO HPME, 200 < RCS PRESS < 600 PSIA AT VESSEL BREACH C2C C2 1.04E-04 HPME, 200 < RCS PRESS < 600 PSIA @ VB, NO WATER IN CAVITY, NO CHR C2D C2 1.04E-04 HPME, 200 < RCS PRESS < 600 PSIA @ VB, NO WATER IN CAVITY, CHR C2E C2 1.04E-04 HPME, 200 < RCS PRESS < 600 PSIA @ VB, WATER IN CAVITY, CHR C21 C2 1.04E-04 HPME, 600 < RCS PRESS < 2000 PSIA @ VB, WATER IN CAVITY C2J C2 1.04E-04 HPME, 600 < RCS PRESS < 2000 PSIA @ VB, NO WATER IN CAVITY C2K C2 1.04E-04 HPME, 600 < RCS PRESS < 2000 PSIA @ VB, NO WATER IN CAVITY, NO CHR C2L C2 1.OOE-05 NO HPME, 600 < RCS PRESS < 2000 PSIA @ VB C2R C2 1.10E-03 HPME, RCS PRESS > 2000 PSIA @ VB, WATER IN CAVITY C2S C2 1.1OE-03 HPME, RCS PRESS > 2000 PSIA @ VB, NO WATER IN CAVITY C2T C2 1.10E-03 HPME, RCS PRESS > 2000 PSIA @ VB, NO SPRAYS OR CHR Page 154 of 256
South Texas Project Risk-Informed GSI-191 Evaluation Volume 2: Probabilistic Risk Analysis RI-GS1191-V02 Revision 1 Table B.3-1 Master Frequency File Used for Point Estimate Event Tree Quantification (Continued)
SF Name Top Event SF Value Split Fraction Description ISF C2U C2 1.OOE-03 NO HPME, ROCKET MODE FAILURE, RCS PRESS > 2000 PSIA @ VB C3A C3 4.17E-02 BOUNDING BASED ON 12% HYDROGEN H3A C3C C3 0.OOE+00 NO CHALLENGE FROM LOW CONC. BURNS C3D C3 1.O0E-01 NO CONTAINMENT FAILURE LIKELY C41 C4 1.OOE+00 CONTAINMENT FAILURE DUE TO LONG TERM OVERPRESSURIZATION C4A C4 3.70E-01
- NO CONTAINMENT HEAT REMOVAL C4B C4 0.00E+00
- HEAT BEING REMOVED FROM CONTAINMENT CCW101 CCWS 2.43E-04 TRAIN A (KA) FAILS TO RUN CCW102 CCWS 2.40E-04 TRAIN B (KB) FAILS TO RUN CCW103 CCWS 2.42E-04 TRAIN C (KC) FAILS TO RUN CCW104 CCWS 9.69E-03 KA RESTART (R/S)
CCW105 CCWS 9.70E-03 KB RESTART (R/S)
CCW106 CCWS 9.54E-03 KC RESTART (R/S)
CCW107 CCWS 9.60E-03 KA STANDBY (STBY)
CCW108 CCWS 9.62E-03 KB STANDBY (STBY)
CCW109 CCWS 9.67E-03 KC STANDBY (STBY)
CCW110 CCWS 1.03E-02 KA OFF CCW111 CCWS 1.02E-02 KB OFF CCW112 CCWS 1.03E-02 KC OFF CCW201 CCWS 3.OOE-06 KA RUN, KB STBY CCW202 CCWS 1.73E-04 KA R/S, KB STBY CCW203 CCWS 3.13E-06 KA RUN, KB START CCW204 CCWS 1.79E-04 KA R/S, KB START CCW205 CCWS 2.94E-06 KA STBY, KB RUN CCW206 CCWS 1.73E-04 KA STBY, KB R/S CCW207 CCWS 3.14E-06 KA START, KB RUN Page 155 of 256
South Texas Project Risk-Informed GSI-191 Evaluation Volume 2: Probabilistic Risk Analysis RI-GSII91-V02 Revision 1 Table B.3-1 Master Frequency File Used for Point Estimate Event Tree Quantification (Continued)
SF Name Top Event SF Value Split Fraction Description ISF CCW208 CCWS 1.78E-04 KA START, KB R/S CCW209 CCWS 1.81E-04 KA STBY, KB START CCW210 CCWS 1.79E-04 KA START, KB STBY CCW211 CCWS 3.01E-06 KA RUN, KC STBY CCW212 CCWS 1.74E-04 KA R/S, KC STBY CCW213 CCWS 3.17E-06 KA RUN, KC START CCW214 CCWS 1.81 E-04 KA R/S, KC START CCW215 CCWS 2.96E-06 KA STBY, KC RUN CCW216 CCWS 1.73E-04 KA STBY, KC R/S CCW217 CCWS 3.18E-06 KA START, KC RUN CCW218 CCWS 1.79E-04 KA START, KC R/S CCW219 CCWS 1.81 E-04 KA STBY, KC START CCW220 CCWS 1.81 E-04 KA START, KC STBY CCW221 CCWS 2.97E-06 KB RUN, KC STBY CCW222 CCWS 1.71 E-04 KB R/S, KC STBY CCW223 CCWS 3.11E-06 KB RUN, KC START CCW224 CCWS 1.79E-04 KB R/S, KC START CCW225 CCWS 3.OOE-06 KB STBY, KC RUN CCW226 CCWS 1.73E-04 KB STBY, KC R/S CCW227 CCWS 3.14E-06 KB START, KC RUN CCW228 CCWS 1.78E-04 KB START, KC R/S CCW229 CCWS 1.79E-04 KB STBY, KC START CCW230 CCWS 1.79E-04 KB START, KC STBY CCW301 CCWS 6.06E-07 KA RUN, KB STBY, KC START CCW302 CCWS 2.55E-05 KA R/S, KB STBY, KC START CCW303 CCWS 5.85E-07 KA RUN, KB START, KC STBY CCW304 CCWS 2.58E-05 KA R/S, KB START, KC STBY Page 156 of 256
South Texas Project Risk-Informed GSI-191 Evaluation Volume 2: Probabilistic Risk Analysis RI-GS1191-V02 Revision 1 Table B.3-1 Master Frequency File Used for Point Estimate Event Tree Quantification (Continued)
SF Name Top Event SF Value Split Fraction Description ISF CCW305 CCWS 5.92E-07 KA STBY, KB RUN, KC START CCW306 CCWS 2.55E-05 KA STBY, KB R/S, KC START CCW307 CCWS 5.88E-07 KA START, KB RUN, KC STBY CCW308 CCWS 2.59E-05 KA START, KB R/S, KC STBY CCW309 CCWS 6.10E-07 KA STBY, KB START, KC RUN CCW310 CCWS 2.58E-05 KA STBY, KB START, KC R/S CCW311 CCWS 5.85E-07 KA START, KB STBY, KC RUN CCW312 CCWS 2.52E-05 KA START, KB STBY, KC R/S CDSQY CDSQ 0.OOE+00 NON CORE DAMAGE SEQUENCES CDSQZ CDSQ 1.OOE+00 CORE DAMAGE SEQUENCES CEA CE 2.08E-03 RCS PRESS < 200 PSIA @ VB, SPRAYS HEA OPERATING @ VB CEB CE 0.00E+00 RCS PRESS < 200 PSIA @ VB, SPRAYS CFA CF 2.34E-05 ALL SUPPORT - STATE ABRUN CFABA CFABA CFAB 2.34E-05 STATE ABRUN - ALL SUPPORT CFABB CFAB 1.65E-04 ABRUN - TRAIN A FAILS CFABC CFAB 1.64E-04 ABRUN - TRAIN B FAILS CFABD CFAB 8.89E-05 ABRUN - TRAIN C FAILS CFABE CFAB 3.35E-02 ABRUN - TRAINS A AND B FAIL CFABF CFAB 1.12E-02 ABRUN - TRAINS A AND C FAIL CFABG CFAB 1.11 E-02 ABRUN - TRAINS B AND C FAIL CFACA CFAC 2.32E-05 STATE ACRUN - ALL SUPPORT CFACB CFAC 1.64E-04 STATE ACRUN - TRAIN A FAILS CFACC CFAC 8.89E-05 STATE ACRUN - TRAIN B FAILS CFACD CFAC 1.64E-04 STATE ACRUN - TRAIN C FAILS CFACE CFAC 1.12E-02 STATE ACRUN - TRAINS A AND B FAIL CFACF CFAC 3.35E-02 STATE ACRUN - TRAINS A AND C FAIL CFACG CFAC 1.12E-02 STATE ACRUN - TRAINS B AND C FAIL Page 157 of 256
South Texas Project Risk-informed GSI-191 Evaluation Volume 2: Probabilistic Risk Analysis RI-GSI191-V02 Revision 1 Table B.3-1 Master Frequency File Used for Point Estimate Event Tree Quantification (Continued)
SF Name Top Event SF Value Split Fraction Description ISF CFB CF 2.32E-05 ALL SUPPORT - STATE BCRUN CFBCA CFBCA CFBC 2.32E-05 STATE BCRUN - ALL SUPPORT CFBCB CFBC 8.92E-05 STATE BCRUN - TRAIN A FAILS CFBCC CFBC 1.64E-04 STATE BCRUN - TRAIN B FAILS CFBCD CFBC 1.63E-04 STATE BCRUN - TRAIN B FAILS CFBCE CFBC 1.12E-02 STATE BCRUN-TRAINS A AND B FAIL CFBCF CFBC 1.12E-02 STATE BCRUN - TRAINS A AND C FAIL CFBCG CFBC 3.30E-02 STATE BCRUN - TRAINS B AND C FAIL CFC CF 2.32E-05 ALL SUPPORT - STATE ACRUN CFACA CFD CF 1.65E-04 STATE ABRUN - TRAIN A FAILS CFABB CFE CF 8.92E-05 STATE BCRUN - TRAIN A FAILS CFBCB CFF CF 1.64E-04 STATE ACRUN - TRAIN A FAILS CFACB CFG CF 1.64E-04 STATE ABRUN - TRAIN B FAILS CFABC CFH CF 1.64E-04 STATE BCRUN - TRAIN B FAILS CFBCC CFI CF 8.89E-05 STATE ACRUN - TRAIN B FAILS CFACC CFJ CF 8.89E-05 STATE ABRUN - TRAIN C FAILS CFABD CFK CF 1.63E-04 STATE BCRUN - TRAIN C FAILS CFBCD CFL CF 1.64E-04 STATE ACRUN - TRAIN C FAILS CFACD CFM CF 3.35E-02 STATE ABRUN - TRAINS A AND B FAILS CFABE CFN CF 1.12E-02 STATE BCRUN - TRAINS A AND B FAILS CFBCE CFO CF 1.12E-02 STATE ACRUN - TRAINS A AND B FAILS CFACE CFP CF 1.12E-02 STATE ABRUN - TRAINS A AND C FAILS CFABF CFQ CF 1.12E-02 STATE BCRUN - TRAINS A AND C FAILS CFBCF CFR CF 3.35E-02 STATE ACRUN - TRAINS A AND C FAILS CFACF CFS CF 1.11E-02 STATE ABRUN - TRAINS B AND C FAILS CFABG CFT CF 3.30E-02 STATE BCRUN - TRAINS B AND C FAILS CFBCG CFU CF 1.12E-02 STATE ACRUN - TRAINS B AND C FAILS CFACG Page 158 of 256
South Texas Project Risk-Informed GSI-191 Evaluation Volume 2: Probabilistic Risk Analysis RI-GSI 191 -V02 Revision 1 Table B.3-1 Master Frequency File Used for Point Estimate Event Tree Quantification (Continued)
SF Name Top Event SF Value Split Fraction Description ISF CFY CF O.OOE+00 GS CFZ CF 1.OOE+00 GF CHA CH 2.32E-04 CVCS, ALL SUPPORT, BCRUN OR ACRUN (CCP A RUN)
CHAA CH 8.84E-03 LOSP, ABRUN, CCPA START, CCPB=F CHAB CH 8.77E-03 LOSP, BCRUN OR ACRUN, CCPB START, CCPA=F CHAC CH 2.07E-03 SGTR, EB=F, BCRUN OR ACRUN, CCPA RUN, CCPB START CHAD CH 2.05E-03 SGTR, EB=F, ABRUN, CCPB RUN, CCPA START CHAE CH 4.21E-03 SGTR, EB=F, BCRUN OR ACRUN, CCPA R/S, CCPB START CHAF CH 4.20E-03 SGTR, EB=F, ABRUN, CCPB R/S, CCPA START CHAG CH 2.30E-03 SGTR, EB=F, BCRUN OR ACRUN, CCPA R, CCPB=F CHAH CH 2.89E-03 SGTR, EB=F, ABRUN, CCPB RUN, CCPA=F CHAI CH 9.54E-03 SGTR, EB=F, BCRUN OR ACRUN, CCPA R/S, CCPB=F CHAJ CH 1.01E-02 SGTR, EB=F, ABRUN, CCPB R/S, CCPA=F CHAK CH 1.07E-02 SGTR, EB=F, ABRUN, CCPA START, CCPB=F CHAL CH 1.13E-02 SGTR, EB=F, BCRUN OR ACRUN, CCPB START, CCPA=F CHB CH 2.31E-04 CVCS, ALL SUPPORT, ABRUN (CCP B RUN)
CHC CH 2.43E-03 BCRUN OR ACRUN, CCPA R/S CHCLA CHCL 1.1 7E-1 1 STATE ABRUN, ALL SUPPORT CHCLB CHCL 1.17E-11 STATE BCRUN, ALL SUPPORT CHCLC CHCL 8.42E-1 1 STATE ACRUN, ALL SUPPORT CHCLD CHCL 2.12E-05 ABRUN
- CCWA=F CHCLE CHCL 6.47E-10 BCRUN
- CCWA=F CHCLF CHCL 4.92E-10 ACRUN
- CCWA=F Page 159 of 256
South Texas Project Risk-Informed GSI-191 Evaluation Volume 2: Probabilistic Risk Analysis RI-GSI191-V02 Revision 1 Table B.3-1 Master Frequency File Used for Point Estimate Event Tree Quantification (Continued)
SF Name Top Event SF Value Split Fraction Description ISF CHCLG CHCL 6.62E-10 ABRUN
- CCWB=F CHCLH CHCL 2.12E-05 BCRUN
- CCWB=F CHCLI CHCL 4.86E-10 ACRUN
- CCWB=F CHCLJ CHCL 6.56E-10 ABRUN * (CCWC=F + CCPB
- LOIA)
CHCLK CHCL 6.74E-10 BCRUN * (CCWC=F + CCPB
- LOIA)
CHCLL CHCL 2.13E-05 ACRUN * (CCWC=F + CCPB
- LOIA)
CHCLM CHCL 1.20E-03 (ABRUN + BCRUN) * (CCWA=F
- CCWB=F + LOIA)
CHCLO CHCL 2.76E-07 ACRUN * (CCWA=F
- CCWB=F + LOIA)
CHCLP CHCL 1.20E-03 (ABRUN + ACRUN)
- CCWA=F * (CCWC=F +
CCPB
- LOIA)
CHCLQ CHCL 5.50E-07 BCRUN
- CCWA=F * (CCWC=F + CCPB
- LOIA)
CHCLS CHCL 5.37E-07 ABRUN
- CCWB=F * (CCWC=F + CCPB
- LOIA)
CHCLT CHCL 1.20E-03 (BCRUN + ACRUN) CCWB=F * (CCWC=F +
CCPB
- LOIA)
CHCMA CHCL 1.18E-11 CCPB, ABRUN CHCMB CHCL 1.17E-11 CCPB, BCRUN CHCMC CHCL 3.25E-10 CCPB, ACRUN CHCMD CHCL 2.13E-05 (CCPB + CCPA)
- ABRUN
- CCWA=F CHCME CHCL 6.83E-10 CCPB, BCRUN
- CCWA=F CHCMF CHCL 1.84E-08 CCPB, ACRUN
- CCWA=F CHCMG CHCL 6.91 E-10 CCPB, ABRUN
- CCWB=F CHCMH CHCL 2.14E-05 (CCPB + CCPA)
- BCRUN
- CCWB=F CHCMI CHCL 1.87E-08 CCPB, ACRUN
- CCWB=F CHCMM CHCL 1.21 E-03 CCPB, (ABRUN + BCRUN)
CCWA=F
- CCWB=F CHCMO CHCL 1.53E-05 CCPB, ACRUN
- CCWA=F
- CCWB=F CHCNA CHCL 1.81E-08 CCPA, ABRUN CHCNB CHCL 1.79E-08 CCPA, BCRUN CHCNC CHCL 5.26E-06 CCPA, ACRUN Page 160 of 256
South Texas Project Risk-Informed GSI-191 Evaluation Volume 2: Probabilistic Risk Analysis RI-GS1191-V02 Revision I Table B.3-1 Master Frequency File Used for Point Estimate Event Tree Quantification (Continued)
SF Name Top Event SF Value Split Fraction Description ISF CHCNE CHCL 1.86E-08 CCPA, BCRUN
- CCWA=F CHCNF CHCL 1.06E-05 CCPA, ACRUN
- CCWA=F CHCNG CHCL 1.86E-08 CCPA, ABRUN
- CCWB=F CHCNI CHCL 1.04E-05 CCPA, ACRUN
- CCWB=F CHCNJ CHCL 1.50E-05 CCPA, ABRUN
- CCWC=F CHCNK CHCL 1.48E-05 CCPA, BCRUN
- CCWC=F CHCNL CHCL 3.60E-05 CCPA, ACRUN
- CCWC=F CHCNP CHCL 1.20E-03 CCPA, (ABRUN + ACRUN)
- CCWA=F
- CCWC=F CHCNQ CHCL 1.57E-05 CCPA, BCRUN
- CCWA=F CCWC=F CHCNS CHCL 1.54E-05 CCPA, ABRUN
- CCWB=F
- CCWC=F CHCNT CHCL 1.21E-03 CCPA, (BCRUN + ACRUN)
- CCWB=F
- CCWC=F CHD CH 2.43E-03 ABRUN, CCPB R/S CHE CH 1.06E-03 BCRUN OR ACRUN, CCPB=F, CCPA RUN CHF CH 1.05E-03 ABRUN, CCPA=F, CCPB RUN CHG CH 8.33E-03 BCRUN OR ACRUN, CCPB=F, CCPA R/S CHH CH 8.27E-03 ABRUN, CCPA=F, CCPB R/S CHI CH 9.38E-03 ABRUN, CCPB=F, CCPA START CHJ CH 9.51E-03 BCRUN OR ACRUN, CCPA=F, CCPB START CHK CH 9.59E-04 SGTR, BCRUN OR ACRUN CHL CH 9.62E-04 SGTR, ABRUN CHM CH 3.15E-03 SGTR, BCRUN OR ACRUN, CCPA RIS CHN CH 3.13E-03 SGTR, ABRUN, CCPB R/S CHO CH 1.23E-03 SGTR, BCRUN OR ACRUN, CCPA RUN, CCPB=F CHP CH 2.88E-03 SGTR, ABRUN, CCPB RUN, CCPA=F (PWR)
CHP1 CH 1.78E-03 SGTR, ABRUN, CCPB RUN, CCPA=F (CLG)
CHQ CH 8.48E-03 SGTR, BCRUN OR ACRUN, CCPA R/S, CCPB=F CHR CH 1.01 E-02 SGTR, ABRUN, CCPB R/S, CCPA=F (PWR)
Page 161 of 256
South Texas Project Risk-Informed GSI-191 Evaluation Volume 2: Probabilistic Risk Analysis RI-GSI 191 -V02 Revision I Table B.3-1 Master Frequency File Used for Point Estimate Event Tree Quantification (Continued)
SF Name Top Event SF Value Split Fraction Description ISF CHR1 CH 9.05E-03 SGTR, ABRUN, CCPB R/S, CCPA=F (CLG)
CHS CH 9.65E-03 SGTR, ABRUN, CCPA START, CCPB=F CHT CH 1.13E-02 SGTR, ACRUN OR BCRUN, CCPB START, CCPA=F (PWR)
CHT1 CH 1.01E-02 SGTR, ACRUN OR BCRUN, CCPB START, CCPA=F (CLG)
CHU CH 1.77E-03 LOSP, BCRUN OR ACRUN, CCPA R/S, CCPB START CHV CH 1.76E-03 LOSP, ABRUN, CCPB R/S. CCPA START CHW CH 7.64E-03 LOSP, BCRUN OR ACRUN, CCPA R/S, CCPB=F CHX CH 7.59E-03 LOSP, ABRUN, CCPB R/S. CCPA=F CHY CH O.OOE+00 GS CHZ CH 1.OOE+00 GF CIA Cl 3.96E-03 LETDOWN, SEAL RETURN, AND CONTAINMENT ISOLATION - ALL SUPPORT CIB Cl 6.75E-03 LETDOWN, SEAL, AND CNMT ISOL - LOSS OF Cl A
CIC Cl 1.63E-02 LETDOWN, SEAL, AND CNMT ISOL - LOSS OF Cl B
CID Cl 4.47E-03 LETDOWN, SEAL, AND CNMT ISOL - LOSS OF Cl C
CIE Cl 7.38E-03 LETDOWN, SEAL, AND CNMT ISOL - LOSS OF Cl A AND Cl C CIF Cl 3.70E-03 SEAL RETURN AND CONT ISOL - ALL SUPPORT CIG Cl 6.74E-03 SEAL RETURN AND CONT ISOL - LOSS OF Cl A CIH Cl 1.64E-02 SEAL RETURN AND CONT ISOL - LOSS OF Cl B CIl CI 4.57E-03 SEAL RETURN AND CONT ISOL - LOSS OF Cl C ClIJ CI 7.49E-03 SEAL RETURN AND CONT ISOL - LOSS OF Cl A AND C CIK Cl 3.90E-03 CONT ISOL W/O SEAL OR LETDOWN - ALL SUPPORT Page 162 of 256
South Texas Project Risk-Informed GSI-191 Evaluation Volume 2: Probabilistic Risk Analysis RI-GSI 191 -V02 Revision 1 Table B.3-1 Master Frequency File Used for Point Estimate Event Tree Quantification (Continued)
SF Name Top Event SF Value Split Fraction Description ISF CIL C1 6.73E-03 CONT ISOL W/O SEAL OR LETDOWN - TRAIN A CI CIM C1 1.58E-02 CONT ISOL W/O SEAL OR LETDOWN - TRAIN B CI CIN Cl 3.86E-03 CONT ISOL W/O SEAL OR LETDOWN - TRAIN C Cl CIO CI 6.77E-03 CONT ISOL W/O SEAL OR LETDOWN - TRAINS A AND C CI CIP CI 1.56E-02 CONT ISOL W/O SEAL OR LETDOWN - TRAINS B AND C CI ClY CI O.OOE+00 GS CIZ CI 1.OOE+00 GF CLAA CLA 1.81 E-08 CCPA, ABRUN CHCNA CLAB CLA 1.79E-08 CCPA, BCRUN CHCNB CLAC CLA 5.26E-06 CCPA, ACRUN CHCNC CLAD CLA 2.13E-05 CCPA, ABRUN
- CCWA=F CHCMD CLAE CLA 1.86E-08 CCPA, BCRUN
- CCWA=F CHCNE CLAF CLA 1.06E-05 CCPA, ACRUN
- CCWA=F CHCNF CLAG CLA 1.86E-08 CCPA, ABRUN
- CCWB=F CHCNG CLAH CLA 2.14E-05 CCPA, BCRUN
- CCWB=F CHCMH CLAI CLA 1.04E-05 CCPA, ACRUN
- CCWB=F CHCNI CLAJ CLA 1.50E-05 CCPA, ABRUN
- CCWC=F CHCNJ CLAK CLA 1.48E-05 CCPA, BCRUN
- CCWC=F CHCNK CLAL CLA 3.60E-05 CCPA, ACRUN
- CCWC=F CHCNL CLAM CLA 1.20E-03 CCPA, (ABRUN + BCRUN)
- CCWA=F
- CCWB=F CHCLM CLAO CLA 2.76E-07 CCPA, ACRUN
- CCWA=F
- CCWB=F CHCLO CLAP CLA 1.20E-03 CCPA, (ABRUN + ACRUN)
- CCWA=F + CCWB=F CHCNP CLAQ CLA 1.57E-05 CCPA, BCRUN
- CCWA=F
- CCWC=F CHCNQ CLAS CLA 1.54E-05 CCPA, ABRUN
- CCWB=F
- CCWC=F CHCNS Page 163 of 256
South Texas Project Risk-Informed GSI-191 Evaluation Volume 2: Probabilistic Risk Analysis RI-GSI191-V02 Revision 1 Table B.3-1 Master Frequency File Used for Point Estimate Event Tree Quantification (Continued)
SF Name Top Event SF Value Split Fraction Description ISF CLAT CLA 1.21 E-03 CCPA, (BCRUN + ACRUN)
- CCWB=F
CLAZ CLA 1.OOE+00 GF (LOIA
- CCWC=F)
CLBA CLB 1.23E-13 CCPB, ABRUN, CLA=S CHCMA CLBAN CLB 6.49E-04 CLA=F CHCLA CLBB CLB 2.OOE-14 CCPB, BCRUN CHCMB CLBBN CLB 6.53E-04 CLA=F CHCLB CLBC CLB 2.41 E-10 CCPB, ACRUN CHCMC CLBCN CLB 1.60E-05 CLA=F CHCLC CLBD CLB 1.05E-07 CCPB, ABRUN
CLBJN CLB 4.38E-05 CLA=F CHCLJ CLBK CLB O.OOE+00 CCPB, BCRUN * (CCWC=F + LOIA)
CLBKN CLB 4.57E-05 CLA=F CHCLK CLBL CLB O.OOE+00 CCPB, ACRUN * (CCWC=F + LOIA)
CLBLN CLB 5.90E-01 CLA=F CHCLL Page 164 of 256
South Texas Project Risk-Informed GSI-191 Evaluation Volume 2: Probabilistic Risk Analysis RI-GSI 191 -V02 Revision 1 Table B.3-1 Master Frequency File Used for Point Estimate Event Tree Quantification (Continued)
SF Name Top Event SF Value Split Fraction Description ISF CLBM CLB 1.63E-05 CCPB, (ABRUN + BCRUN)
- CCWA=F
- CCWA=F
- CCWA=F * (CCWC=F
+ LOIA)
CLBPN CLB 9.99E-01 CLA=F CHCLP CLBQ CLB O.OOE+00 CCPB, BCRUN
- CCWA=F * (CCWC=F + LOIA)
CLBQN CLB 3.51 E-02 CLA=F CHCLQ CLBS CLB 0.OOE+00 CCPB, ABRUN
- CCWB=F * (CCWC=F + LOIA)
CLBSN CLB 3.50E-02 CLA=F CHCLS CLBT CLB O.OOE+00 CCPB, (BCRUN + ACRUN)
- CCWB=F * (CCWC=F
+ LOIA)
CLBTN CLB 9.92E-01 CLA=F CHCLT CLBY CLB O.OOE+00 GS -(GTRAN + SGTR)
CLBZ CLB 1.OOE+00 GF (LOIA
- CCWA=F
- CCWB=F)
CLDA CLB 6.45E-10 CCPB, ABRUN
- LOIA
- LOIA
- LOIA
- CCWA=F CHCLP CLDFN CLB 1.78E-03 CLA=F CHCLF Page 165 of 256
South Texas Project Risk-Informed GSI-191 Evaluation Volume 2: Probabilistic Risk Analysis RI-GSI191-V02 Revision I Table B.3-1 Master Frequency File Used for Point Estimate Event Tree Quantification (Continued)
SF Name Top Event SF Value Split Fraction Description ISF CLDG CLB 5.37E-07 CCPB, ABRUN
- LOIA
- LOIA
- LOIA
- LOIA
- CCWC=F CHCLJ CLDK CLB 6.74E-10 CCWB, BCRUN
- LOIA
- CCWC=F CHCLK CLDL CLB 2.13E-05 CCWB, ACRUN
- LOIA
- CCWC=F CHCLL CLDP CLB 1.20E-03 CCWB, ABRUN
- LOIA
- CCWA=F
- CCWC=F CHCLP CLDQ CLB 5.50E-07 CCWB, BCRUN
- LOIA
- CCWA=F
- CCWC=F CHCLQ CLDS CLB 5.37E-07 CCWB, ABRUN
- LOIA
- CCWB=F
- CCWC=F CHCLS CLDT CLB 1.20E-03 CCWB, BCRUN
- LOIA
- CCWB=F
- CCWC=F CHCLT CNDA CND 1.30E-02 CONDENSATE SYSTEM - POST TRIP CNDY CND O.OOE+00 GS CNDZ CND 1.OOE+00 GF CPA CP 5.93E-08 CONTAINMENT PURGE (CP) ISOLATION -ALL SUPPORT CPB CP 5.71 E-06 CP - LOSS OF TRAIN B SUPPORT CPC CP 8.28E-03 CP - NO SUPPORT AVAILABLE CPD CP 9.74E-06 CP - LOSS OF TRAIN A SUPPORT CPE CP 7.02E-06 CP - ALL SUPPORT, PURGE OPEN CPF CP 6.92E-04 CP - LOSS OF TRAIN B, PURGE OPEN CPG CP 1.OOE+00 CP - NO SUPPORT, PURGE OPEN CPH CP 1.18E-03 CP - LOSS OF TRAIN A, PURGE OPEN CPY CP O.OOE+00 GS CS1AA CS 9.87E-01 State: CSABC: CSS TRAIN ABC SUPPORT AVAILABLE Page 166 of 256
South Texas Project Risk-Informed GSI-191 Evaluation Volume 2: Probabilistic Risk Analysis RI-GSI 191 -V02 Revision I Table B.3-1 Master Frequency File Used for Point Estimate Event Tree Quantification (Continued)
SF Name Top Event SF Value Split Fraction Description ISF CS1AB CS O.OOE+00 State: CSABC: CSS TRAIN BC SUPPORT AVAILABLE CS1AC CS O.OOE+00 State: CSABC: CSS TRAIN AC SUPPORT AVAILABLE CS1AD CS O.OE+00 State: CSABC: CSS TRAIN C SUPPORT AVAILABLE CS1AE CS O.OOE+00 State: CSABC: CSS TRAIN AB SUPPORT AVAILABLE CS1AF CS O.OOE+00 State: CSABC: CSS TRAIN B SUPPORT AVAILABLE CS1AG CS O.OOE+00 State: CSABC: CSS TRAIN A SUPPORT AVAILABLE CS1AH CS O.OOE+00 State: CSABC: CSS TRAIN ABC SUPPORT UNAVAILABLE CS2AA CS 4.20E-03 State: CSAB: CSS TRAIN ABC SUPPORT AVAILABLE CS2AB CS O.OOE+00 State: CSAB: CSS TRAIN BC SUPPORT AVAILABLE CS2AC CS O.OOE+00 State: CSAB: CSS TRAIN AC SUPPORT AVAILABLE CS2AD CS O.OOE+00 State: CSAB: CSS TRAIN C SUPPORT AVAILABLE CS2AE CS 9.92E-01 State: CSAB: CSS TRAIN AB SUPPORT AVAILABLE CS2AF CS O.OOE+00 State: CSAB: CSS TRAIN B SUPPORT AVAILABLE CS2AG CS O.OOE+00 State: CSAB: CSS TRAIN A SUPPORT AVAILABLE CS2AH CS O.OOE+00 State: CSAB: CSS TRAIN ABC SUPPORT UNAVAILABLE CS3AA CS 4.05E-03 State: CSAC. CSS TRAIN ABC SUPPORT AVAILABLE CS3AB CS O.OOE+00 State: CSAC: CSS TRAIN BC SUPPORT I AVAILABLE Page 167 of 256
South Texas Project Risk-Informed GSI-191 Evaluation Volume 2: Probabilistic Risk Analysis R1-GSI191-V02 Revision 1 Table B.3-1 Master Frequency File Used for Point Estimate Event Tree Quantification (Continued)
SF Name Top Event SF Value Split Fraction Description ISF CS3AC CS 9.91 E-01 State: CSAC: CSS TRAIN AC SUPPORT AVAILABLE CS3AD CS O.OOE+00 State: CSAC: CSS TRAIN C SUPPORT AVAILABLE CS3AE CS O.OOE+00 State: CSAC: CSS TRAIN AB SUPPORT AVAILABLE CS3AF CS 0.OOE+00 State: CSAC: CSS TRAIN B SUPPORT AVAILABLE CS3AG CS O.OOE+00 State: CSAC: CSS TRAIN A SUPPORT AVAILABLE CS3AH CS O.00E+00 State: CSAC: CSS TRAIN ABC SUPPORT UNAVAILABLE CS4AA CS 4.20E-03 State: CSBC: CSS TRAIN ABC SUPPORT AVAILABLE CS4AB CS 9.92E-01 State: CSBC: CSS TRAIN BC SUPPORT AVAILABLE CS4AC CS O.OOE+00 State: CSBC: CSS TRAIN AC SUPPORT AVAILABLE CS4AD CS O.OOE+00 State: CSBC: CSS TRAIN C SUPPORT AVAILABLE CS4AE CS O.OOE+00 State: CSBC: CSS TRAIN AB SUPPORT AVAILABLE CS4AF CS O.OOE+00 State: CSBC: CSS TRAIN B SUPPORT AVAILABLE CS4AG CS O.OE+00 State: CSBC: CSS TRAIN A SUPPORT AVAILABLE CS4AH CS o.o0E+00 State: CSBC: CSS TRAIN ABC SUPPORT UNAVAILABLE CS5AA CS 9.37E-05 State: CSA: CSS TRAIN ABC SUPPORT AVAILABLE CS5AB CS O.OOE+00 State: CSA: CSS TRAIN BC SUPPORT AVAILABLE CS5AC CS 4.29E-03 State: CSA: CSS TRAIN AC SUPPORT I__ _
_AVAILABLE I
_I Page 168 of 256
South Texas Project Risk-Informed GSI-191 Evaluation Volume 2: Probabilistic Risk Analysis RI-GSI 191 -V02 Revision I Table B.3-1 Master Frequency File Used for Point Estimate Event Tree Quantification (Continued)
SF Name Top Event SF Value Split Fraction Description ISF CS5AD CS 0.OOE+00 State: CSA: CSS TRAIN C SUPPORT AVAILABLE CS5AE CS 4.14E-03 State: CSA: CSS TRAIN AB SUPPORT AVAILABLE CS5AF CS O.OOE+00 State: CSA: CSS TRAIN B SUPPORT AVAILABLE CS5AG CS 9.96E-01 State: CSA: CSS TRAIN A SUPPORT AVAILABLE CS5AH CS O.OOE+00 State: CSA: CSS TRAIN ABC SUPPORT UNAVAILABLE CS6AA CS 9.47E-05 State: CSB: CSS TRAIN ABC SUPPORT AVAILABLE CS6AB CS 4.29E-03 State: CSB: CSS TRAIN BC SUPPORT AVAILABLE CS6AC CS O.OOE+00 State: CSB: CSS TRAIN AC SUPPORT AVAILABLE CS6AD CS O.OOE+00 State: CSB: CSS TRAIN C SUPPORT AVAILABLE CS6AE CS 4.29E-03 State: CSB: CSS TRAIN AB SUPPORT AVAILABLE CS6AF CS 9.96E-01 State: CSB: CSS TRAIN B SUPPORT AVAILABLE CS6AG CS 0.00E+00 State: CSB: CSS TRAIN A SUPPORT AVAILABLE CS6AH CS 0.OOE+00 State: CSB: CSS TRAIN ABC SUPPORT UNAVAILABLE CS7AA CS 9.37E-05 State: CSC: CSS TRAIN ABC SUPPORT AVAILABLE CS7AB CS 4.14E-03 State: CSC: CSS TRAIN BC SUPPORT AVAILABLE CS7AC CS 4.29E-03 State: CSC: CSS TRAIN AC SUPPORT AVAILABLE CS7AD CS 9.96E-01 State: CSC: CSS TRAIN C SUPPORT AVAILABLE CS7AE CS O.OOE+00 State: CSC: CSS TRAIN AB SUPPORT AVAILABLE CS7AF CS O.OOE+00 State: CSC: CSS TRAIN B SUPPORT AVAILABLE CS7AG CS O.OOE+00 State: CSC: CSS TRAIN A SUPPORT AVAILABLE Page 169 of 256
South Texas Project Risk-Informed GSI-191 Evaluation Volume 2: Probabilistic Risk Analysis RI-GSI 19 l-V02 Revision 1 Table B.3-1 Master Frequency File Used for Point Estimate Event Tree Quantification (Continued)
SF Name Top Event SF Value Split Fraction Description ISF CS7AH CS O.OOE+00 State: CSC: CSS TRAIN ABC SUPPORT UNAVAILABLE CS8AA CS 3.66E-05 State: CSNO: CSS TRAIN ABC SUPPORT AVAILABLE CS8AB CS 1.30E-04 State: CSNO: CSS TRAIN BC SUPPORT AVAILABLE CS8AC CS 1.31 E-04 State: CSNO: CSS TRAIN AC SUPPORT AVAILABLE CS8AD CS 4.42E-03 State: CSNO: CSS TRAIN C SUPPORT AVAILABLE CS8AE CS 1.30E-04 State: CSNO: CSS TRAIN AB SUPPORT AVAILABLE CS8AF CS 4.27E-03 State: CSNO: CSS TRAIN B SUPPORT AVAILABLE CS8AG CS 4.42E-03 State: CSNO: CSS TRAIN A SUPPORT AVAILABLE CS8AH CS 1.OOE+00 State: CSNO: CSS TRAIN ABC SUPPORT UNAVAILABLE CSY CS O.OOE+00 GS CSZ CS 1.OOE+00 GF CV1 G CV 9.08E-02 GR LOOP with 1 SDG at 4 hrs CV1 P CV 8.44E-02 PC LOOP with 1 SDG at 4 hrs OMA CV1 S CV 9.34E-02 SC LOOP with 1 SDG at 4 hrs CV1W CV 2.67E-01 WR LOOP with 1 SDG at 4 hrs CV2G CV 3.98E-02 GR LOOP with 2 SDGs at 4 hrs CV2P CV 3.82E-02 PC LOOP with 2 SDGs at 4 hrs OMB CV2S CV 4.24E-02 SC LOOP with 2 SDGs at 4 hrs CV2W CV 1.44E-01 WR LOOP with 2 SDGs at 4 hrs CV3G CV 5.33E-02 GR LOOP with 3 SDGs at 4 hrs OMC CV3P CV 5.09E-02 PC LOOP with 3 SGDs at 4 hrs OMC CV3S CV 5.65E-02 SC LOOP with 3 SDGs at 4 hrs OMC Page 170 of 256
South Texas Project Risk-Informed GSI-191 Evaluation Volume 2: Probabilistic Risk Analysis RI-GSI 19 1-V02 Revision 1 Table B.3-1 Master Frequency File Used for Point Estimate Event Tree Quantification (Continued)
SF Name Top Event SF Value Split Fraction Description ISF CV3W CV 1.89E-01 WR LOOP with 3 SDGs at 4 hrs OMC CVY CV O.OOE+00 GS CVZ CV 1.OOE+00 GUARANTEED NO RECOVERY D4ABCD DCLP 1.42E-11 E1All, E1B11, ELC11, ElD11, LOOP DAA DA 2.82E-05 EAl 1, ALL SUPPORT DCAA DAB DA 4.30E-03 ElAll, LOSP DC1A DAC DA 4.30E-03 ElAl1, NO AC (4 HOURS)
DC1A DAD DA 2.73E-05 E1A11, BATTERY OUT OF SERVICE DCAD DAY DA o.o0E+00 GS DAZ DA 1.OOE+00 GF DBA DB 2.79E-05 ElB11, ALL SUPPORT DCBA DBB DB 4.31E-03
- El113, LOSP DC1B DBC1 DB 4.32E-03 EB 11, NO AC (4 HOURS), NO AC FOR TRAIN A, DC1B A=S DBC2 DB 1.05E-03 El B 11, NO AC (4 HOURS), NO AC FOR TRAIN A, DC2AB A=F DBC3 DB 4.31E-03 ElB11, NO AC (4 HOURS), NO AC FOR TRAIN A, DC1B A=B DBCA DBC 5.OOE-01
- DEBRIS TRAPPED IN CAVITY DBCC DBC O.OOE+00
- DEBRIS DISPURSED AND WATER AVAILABLE DBCZ DBC 1.OOE+00 DEBRIS NOT COOLED DBD DB 2.72E-05 El 1B11, BATTERY OUT OF SERVICE DBY DB O.OOE+00 GS DBZ DB 1.OOE+00 GF DC1A DCLP 4.30E-03 ElAll, LOOP DClB DCLP 4.31 E-03
South Texas Project Risk-Informed GSI-191 Evaluation Volume 2: Probabilistic Risk Analysis RI-GSI191-V02 Revision 1 Table B.3-1 Master Frequency File Used for Point Estimate Event Tree Quantification (Continued)
SF Name Top Event SF Value Split Fraction Description ISF DC2AB DCLP 4.51E-06 ElAll, E1B11, LOOP DC2AC DCLP 4.42E-06 ElAll, ElCll, LOOP DC2AD DCLP 4.55E-06 ElAll, ElC11, LOOP DC2BC DCLP 4.51E-06 E1B11, ElC11, LOOP DC2BD DCLP 4.45E-06 ElB11, ElD11, LOOP DC2CD DCLP 4.47E-06 EIC11, E1D11, LOOP DC3ABC DCLP 6.57E-09 ElAll, E1B11, ElC1, LOOP DC3ABD DCLP 6.80E-09 ElAl1, ElB11, ElD11, LOOP DC3ACD DCLP 6.1OE-09 ElAl1, ElC1l, ElD11, LOOP DC3BCD DCLP 6.58E-09
- EB113, ElC11, EID11, LOOP DCA DC 2.80E-05 ElC11, ALL SUPPORT DCCA DCAA DCLP 2.82E-05 ElA1 1, ALL SUPPORT DCAC DCLP 4.29E-03 ElAl1, NO AC (4 HOURS)
DCAD DCLP 2.73E-05 ElAl 1, BATTERY OUT OF SERVICE DCB DC 4.33E-03 ElC11, LOSP DCl C DCBA DCLP 2.79E-05 El 1B11, ALL SUPPORT DCBC DCLP 4.29E-03 ElB11, NO AC (4 HOURS)
DCBD DCLP 2.72E-05 ElB11, BATTERY OUT OF SERVICE DCCl DC 4.36E-03 El C11, NO AC (4 HOURS) TO A, B, C, A=S B=S DCIC DCC2 DC 1.05E-03 El Cl 1, NO AC (4 HOURS) TO A, B, C, A=S B=F DC2BC DCC3 DC 1.03E-03 ElCl 1, NO AC (4 HOURS) TO A, B, C, A=F B=S DC2AC DCC4 DC 1.46E-03 El C11, NO AC (4 HOURS) TO A, B, C, A=F B=F DC3ABC DCC5 DC 4.34E-03 ElCll, NO AC (4 HOURS) TO B, C, A=B B=S DCIC DCC6 DC 1.05E-03 ElCl 1, NO AC (4 HOURS) TO B, C, A=B B=F DC2BC DCC7 DC 4.34E-03 El Cli, NO AC (4 HOURS) TO A, C, A=S B=B DClC DCC8 DC 1.03E-03 ElCl 1, NO AC (4 HOURS) TO A, C, A=F B=B DC2AC DCC9 DC 4.33E-03 ElCl 1, NO AC (4 HOURS) TO C, A=B B=B DClC Page 172 of 256
South Texas Project Risk-Informed GSI-191 Evaluation Volume 2: Probabilistic Risk Analysis RI-GSI 19 1-V02 Revision I Table B.3-1 Master Frequency File Used for Point Estimate Event Tree Quantification (Continued)
SF Name Top Event SF Value Split Fraction Description ISF DCCA DCLP 2.80E-05 E1C11, ALL SUPPORT DCCC DCLP 4.33E-03 ElCl 1, NO AC (4 HOURS)
DCCD DCLP 2.72E-05 ElC1 1, BATTERY OUT OF SERVICE DCD DC 2.72E-05 ElC11, BATTERY OUT OF SERVICE DCCD DCDA DCLP 2.23E-05 ElD11, ALL SUPPORT DCDC DCLP 4.32E-03 E1D1 1, NO AC (4 HOURS)
DCDD DCLP 2.13E-05 El D11, BATTERY OUT OF SERVICE DCY DC O.OOE+00 GS DCZ DC 1.OOE+00 GF DDA DD 2.23E-05 El D11, ALL SUPPORT DCDA DDB DD 4.40E-03 ElD11, LOSP DClD DDCl DD 4.45E-03 El D11, NO AC (4 HOURS) TO A, B, C,D A=S B=S DCl D C=S DDC10 DD 1.03E-03 ElD11, NO AC (4 HOURS) TO B, C,D A=B B=S DC2CD C=F DDC1 1 DD 1.03E-03 El D11, NO AC (4 HOURS) TO B, C,D A=B B=F DC2BD C=S DDC12 DD 1.46E-03 ElD11, NO AC (4 HOURS) TO B, C,D A=B B=F DC3BCD C=F DDC13 DD 4.43E-03 El D11, NO AC (4 HOURS) TO A, C,D A=S B=B DCIlD C=S DDC14 DD 1.03E-03 ElD11, NO AC (4 HOURS) TO A, C,D A=S B=B DC2CD C=F DDC15 DD 1.06E-03 El D1 1, NO AC (4 HOURS) TO A, C,D A=F B=B DC2AD C=S DDC16 DD 1.38E-03 ElD11, NO AC (4 HOURS) TO A, C,D A=F B=B DC3ACD C=F DDC17 DD 4.43E-03 El D11, NO AC (4 HOURS) TO A, B,D A=S B=S DClD C=B DDC18 DD 1.03E-03 E1D11, NO AC (4 HOURS) TOA, B,DA=S B=F DC2BD C=B Page 173 of 256
South Texas Project Risk-Informed GSI-191 Evaluation Volume 2: Probabilistic Risk Analysis RI-GSI191-V02 Revision 1 Table B.3-1 Master Frequency File Used for Point Estimate Event Tree Quantification (Continued)
SF Name Top Event SF Value Split Fraction Description ISF DDC19 DD 1.06E-03 El D11, NO AC (4 HOURS) TO A, B,D A=F B=S DC2AD C=B DDC2 DD 1.03E-03 ElD11, NO AC (4 HOURS) TO A, B, C,D A=S B=S DC2CD C=F DDC20 DD 1.51E-03 El D11, NO AC (4 HOURS) TO A, B,D A=F B=F DC3ABD C=B DDC21 DD 4.42E-03 ElDl1, NO AC (4 HOURS) TO C,D A=B B=B C=S DC1D DDC22 DD 1.03E-03 El D11, NO AC (4 HOURS) TO C,D A=B B=B C=F DC2CD DDC23 DD 4.42E-03 El D11, NO AC (4 HOURS) TO B,D A=B B=S C=B DClD DDC24 DD 1.03E-03 El D11, NO AC (4 HOURS) TO B,D A=B B=F C=B DC2BD DDC25 DD 4.42E-03 El D11, NO AC (4 HOURS) TO A,D A=S B=B C=B DCl D DDC26 DD 1.06E-03 El D11, NO AC (4 HOURS) TO A,D A=F B=B C=B DC2AD DDC27 DD 4.40E-03 El D11, NO AC (4 HOURS) TO D A=B B=B C=B DC1 D DDC3 DD 1.03E-03 El D11, NO AC (4 HOURS) TO A, B, C,D A=S B=F DC28D C=S DDC4 DD 1.46E-03 ElD11, NO AC (4 HOURS) TO A, B, C,D A=S B=F DC3BCD C=F DDC5 DD 1.06E-03 ElD11, NO AC (4 HOURS) TO A, B, C,D A=F B=S DC2AD C=S DDC6 DD 1.38E-03 El D11, NO AC (4 HOURS) TO A, B, C,D A=F B=S DC3ACD C=F DDC7 DD 1.51E-03 El D11, NO AC (4 HOURS) TO A, B, C,D A=F B=F DC3ABC C=S DDC8 DD 2.16E-03 ElD11, NO AC (4 HOURS) TO A, B, C,D A=F B=F D4ABCD C=F DDC9 DD 4.43E-03 El D11, NO AC (4 HOURS) TO B, C,D A=B B=S DC1D C=S DDD DD 2.13E-05 El D11, BATTERY OUT OF SERVICE DCDD DDY DD O.OOE+00 GS DDZ DD 1.OOE+00 GF DM2A DM 9.73E-03 THREE SMOKE PURGE, TWO REQUIRED Page 174 of 256
South Texas Project Risk-Informed GSI-191 Evaluation Volume 2: Probabilistic Risk Analysis RI-GS1191-V02 Revision 1 Table B.3-1 Master Frequency File Used for Point Estimate Event Tree Quantification (Continued)
SF Name Top Event SF Value Split Fraction Description ISF DM2B DM 6.53E-02 TWO SMOKE PURGE, TWO REQUIRED, A AND B DM2C DM 6.56E-02 TWO SMOKE PURGE, TWO REQUIRED, A AND C DM2D DM 6.38E-02 TWO SMOKE PURGE, TWO REQUIRED, B AND C DMA DM 2.12E-03 3 SMOKE PURGE TRAINS DMB DM 4.26E-03 SMOKE PURGE TRAINS A AND B DMC DM 4.79E-03 SMOKE PURGE TRAINS A AND C DMD DM 4.53E-03 SMOKE PURGE TRAINS B AND C DME DM 3.51E-02 SMOKE PURGE TRAIN A DMF DM 3.73E-02 SMOKE PURGE TRAIN B DMG DM 3.52E-02 SMOKE PURGE TRAIN C DMY DM 0.OOE+00 GS DMZ DM 1.OOE+00 GF DUM1 DUM O.OOE+00 SLOCA, Hazard Levels:.501 to 2 DUM2 DUM 3.79E-01 MLOCA, Hazard Levels: 2 to 6 DUM3 DUM 1.OOE+00 LLOCA, Hazard Levels: 6 to 9.99 DUMF DUM 1.OOE+00 Guaranteed Failure DUMS DUM 0.OOE+00 Guaranteed Success EAA EA 2.40E-04 BUS ElA - 13.8 KV BUS 1 F AVAILABLE EAB EA 2.63E-04 BUS ElA - TRAIN A SUPPORT EQUIPMENT NOT OPERATING EAC EA 8.53E-03 BUS E1A-O - LOOP EP4A1 EACi EA 8.57E-03 BUS E1A-O - LOOP EAC2 EA 3.80E-03 BUS EIA-S - LOOP EAD EA 3.79E-03 BUS EIA-S - LOOP EP4A2 EAY EA 0.OOE+00 GS EAZ EA 1.OOE+00 GF EB1 EB 8.14E-03 BUS E1B-O - LOOP, EA=B EB2 EB 3.82E-03 BUS E1B-S - LOOP, EA=B Page 175 of 256
South Texas Project Risk-Informed GSI-191 Evaluation Volume 2: Probabilistic Risk Analysis RI-GSI 19 l-V02 Revision 1 Table B.3-1 Master Frequency File Used for Point Estimate Event Tree Quantification (Continued)
SF Name Top Event SF Value Split Fraction Description ISF EBA EB 2.42E-04 BUS ElB - 13.8KV BUS 1G AVAILABLE EBB EB 2.66E-04 BUS El B - TRAIN B SUPPORT EQUIPMENT NOT OPERATING EBC EB 8.08E-03 BUS E1B - LOOP, EA=S (A=O, B=O)
EP4B1 EBD EB 2.13E-02 BUS E11B, EA=F EP4AB1 EBE EB 3.67E-03 BUS E1B - LOOP, EA=S (A=O, B=S)
EP4B2 EBF EB 1.63E-02 BUS E1B, EA=F EP4AB2 EBG EB 8.09E-03 BUS E1B, LOOP, EA=S (EA=S, EB=O)
EP4B1 EBH EB 3.64E-02 BUS E1B, EA=F EP4AB3 EBI EB 8.19E-03 BUS ElB-O - LOOP, EA=B EP4B1 EBJ EB 3.78E-03 BUS ElB-S-LOOP, EA=B EP4B2 EBY EB O.OOE+00 GS EBZ EB 1.OOE+00 GF ECl EC 9.35E-03 BUS ElC-O, EA=B, EB=B EC101 ECHS 1.37E-03 ECH TRAIN A (ECA) RUN EC102 ECHS 1.38E-03 ECH TRAIN B (ECB) RUN EC103 ECHS 1.37E-03 ECH TRAIN C (ECC) RUN EC104 ECHS 1.29E-02 ECH A RESTART (R/S)
EC105 ECHS 1.29E-02 ECH B R/S EC106 ECHS 1.29E-02 ECH C R/S EC107 ECHS 1.52E-02 ECH A OFF EC108 ECHS 1.51 E-02 ECH B OFF EC109 ECHS 1.53E-02 ECH C OFF EC2 EC 3.84E-03 BUS E1C-S - LOOP, EA=B, EB=B EC201 ECHS 5.02E-06 ECH A RUN, ECH B RUN, ECC=B EC202 ECHS 2.09E-05 ECH A RUN, ECH B R/S, ECC=B EC203 ECHS 2.09E-05 ECH A R/S, ECH B RUN, ECC=B EC204 ECHS 2.39E-04 ECH A R/S, ECH B R/S, ECC=B Page 176 of 256
South Texas Project Risk-Informed GSI-191 Evaluation Volume 2: Probabilistic Risk Analysis RI-GSI 191 -V02 Revision I Table B.3-1 Master Frequency File Used for Point Estimate Event Tree Quantification (Continued)
SF Name Top Event SF Value Split Fraction Description ISF EC205 ECHS 2.41 E-05 ECH A RUN, ECH B OFF, ECC=B EC206 ECHS 2.70E-04 ECH A R/S, ECH B OFF, ECC=B EC207 ECHS 2.40E-05 ECH A OFF, ECH B RUN, ECC=B EC208 ECHS 2.70E-04 ECH A OFF, ECH B R/S, ECC=B EC209 ECHS 5.02E-06 ECH A RUN, ECH C RUN, ECB=B EC210 ECHS 2.08E-05 ECH A RUN, ECH C R/S, ECB=B EC211 ECHS 2.08E-05 ECH A R/S, ECH C RUN, ECB=B EC212 ECHS 2.38E-04 ECH A R/S, ECH C R/S, ECB=B EC213 ECHS 2.41 E-05 ECH A RUN, ECH C OFF, ECB=B EC214 ECHS 2.69E-04 ECH A R/S, ECH C OFF, ECB=B EC215 ECHS 2.41 E-05 ECH A OFF, ECH C RUN, ECB=B EC216 ECHS 2.68E-04 ECH A OFF, ECH C R/S, ECB=B EC217 ECHS 5.03E-06 ECH B RUN, ECH C RUN, ECA=B EC218 ECHS 2.1OE-05 ECH B RUN, ECH C R/S, ECA=B EC219 ECHS 2.1OE-05 ECH B R/S, ECH C RUN, ECA=B EC220 ECHS 2.40E-04 ECH B R/S, ECH C R/S, ECA=B EC221 ECHS 2.40E-05 ECH B RUN, ECH C OFF, ECA=B EC222 ECHS 2.68E-04 ECH B R/S, ECH C OFF, ECA=B EC223 ECHS 2.42E-05 ECH B OFF, ECH C RUN, ECA=B EC224 ECHS 2.70E-04 ECH B OFF, ECH C R/S, ECA=B EC301 ECHS 9.63E-07 ECH A RUN, ECH B RUN, ECH C OFF EC302 ECHS 1.31 E-06 ECH A RUN, ECH B R/S, ECH C OFF EC303 ECHS 1.32E-06 ECH A R/S, ECH B RUN, ECH C OFF EC304 ECHS 2.20E-05 ECH A R/S, ECH B R/S, ECH C OFF EC305 ECHS 9.54E-07 ECH A RUN, ECH B OFF, ECH C RUN EC306 ECHS 1.32E-06 ECH A RUN, ECH B OFF, ECH C R/S EC307 ECHS 1.32E-06 ECH A R/S, ECH B OFF, ECH C RUN Page 177 of 256
South Texas Project Risk-Informed GSI-191 Evaluation Volume 2: Probabilistic Risk Analysis RI-GS1191 -V02 Revision 1 Table B.3-1 Master Frequency File Used for Point Estimate Event Tree Quantification (Continued)
SF Name Top Event SF Value Split Fraction Description ISF EC308 ECHS 2.18E-05 ECH A R/S, ECH B OFF, ECH C R/S EC309 ECHS 9.56E-07 ECH A OFF, ECH B RUN, ECH C RUN EC310 ECHS 1.33E-06 ECH A OFF, ECH B RUN, ECH C R/S EC311 ECHS 1.32E-06 ECH A OFF, ECH B R/S, ECH C RUN EC312 ECHS 2.17E-05 ECH A OFF, ECH B R/S, ECH C R/S ECA EC 2.41E-04 BUS E1C - 13.8KV BUS 1H AVAILABLE ECAA ECA 1.37E-03 ECH TRAIN A RUN EC101 ECAB ECA 1.29E-02 ECH TRAIN A R/S EC104 ECAC ECA 1.52E-02 ECH TRAIN A OFF EC107 ECAE EC 9.23E-03 EA=B, E1B-S, E1C-O EP4C1 ECAF EC 3.80E-02 EA=B, EB=F, E1C-O EP4BC2 ECAG EC 9.23E-03 EA=B, E1B-O, ElC-O EP4C1 ECAH EC 2.29E-02 EA=B, EB=F, E1C-O EP4BC3 ECAI EC 9.34E-03 BUS E1C-O, EA=B, EB=B EP4C1 ECAJ EC 3.80E-03 BUS E1C-S - LOOP, EA=B, EB=B EP4C2 ECAK EC 9.24E-03 EB=B, EIA-S, E1C-O EP4C1 ECAL EC 3.74E-02 EB=B, EA=F, E1C-O EP4AC4 ECAM EC 3.69E-03 EA=B, E11B-O, E1C-S EP4C2 ECAN EC 1.68E-02 EA=B, EB=F, E1C-S EP4BC1 ECAY ECA O.OOE+00 GS ECAZ ECA 1.OOE+00 GF ECB EC 2.62E-04 BUS ElC - TRAIN C SUPPORT EQUIPMENT NOT OPERATING ECBA ECB 1.38E-03 ECH A RUN, ECH B RUN EC102 ECBB ECB 3.66E-03 ECA=F, ECH B RUN EC201 ECBC ECB 1.29E-02 ECH A RUN, ECH B R/S EC105 ECBD ECB 1.53E-02 ECA=F, ECH B R/S EC202 ECBE ECB 1.38E-03 ECH A R/S, ECH B RUN EC102 Page 178 of 256
South Texas Project Risk-Informed GSI-191 Evaluation Volume 2: Probabilistic Risk Analysis RI-GSI 191 -V02 Revision 1 Table B.3-1 Master Frequency File Used for Point Estimate Event Tree Quantification (Continued)
SF Name Top Event SF Value Split Fraction Description ISF ECBF ECB 1.62E-03 ECA=F, ECH B RUN EC203 ECBG ECB 1.28E-02 ECH A R/S, ECH B R/S EC1 05 ECBH ECB 1.85E-02 ECA=F, ECH B R/S EC204 ECBI ECB 1.51 E-02 ECH A RUN, ECH B OFF EC108 ECBJ ECB 1.75E-02 ECA=F, ECH B OFF EC205 ECBK ECB 1.51 E-02 ECH A R/S, ECH B OFF EC108 ECBL ECB 2.09E-02 ECA=F, ECH B OFF EC206 ECBM ECB 1.38E-03 ECH A OFF, ECH B RUN EC102 ECBN ECB 1.58E-03 ECA=F, ECH B RUN EC207 ECBO ECB 1.28E-02 ECH A OFF, ECH B R/S EC1 05 ECBP ECB 1.77E-02 ECA=F, ECH B R/S EC208 ECBQ ECB 1.38E-03 ECH TRAIN B RUN EC102 ECBR ECB 1.29E-02 ECH TRAIN B R/S EC105 ECBS ECB 1.51E-02 ECH TRAIN B OFF EC108 ECBY ECB 0.OOE+00 GS ECBZ ECB 1.OOE+00 GF ECC EC 3.59E-03 BUS ElC - LOOP, EA-O, EB-O, EC-S EP4C2 ECCA ECC 1.53E-02 ECH A RUN, ECH B RUN, ECH C OFF EC109 ECCAA ECC 1.42E-03 ECH A R/S, ECH B OFF, ECH C RUN EC103 ECCAB ECC 1.54E-03 ECA=S, ECB=F, ECH C RUN EC223 ECCAC ECC 1.54E-03 ECA=F, ECB=S, ECH C RUN EC211 ECCAD ECC 4.89E-03 ECA=F, ECB=F, ECH C RUN EC307 ECCAE ECC 1.28E-02 ECH A R/S, ECH B OFF, ECH C R/S EC106 ECCAF ECC 1.67E-02 ECA=S, ECB=F, ECH C R/S EC224 ECCAG ECC 1.71 E-02 ECA=F, ECB=S, ECH C R/S EC212 ECCAH ECC 8.06E-02 ECA=F, ECB=F, ECH C R/S EC308 ECCAI ECC 1.37E-03 ECH A OFF, ECH B RUN, ECH C RUN EC103 Page 179 of 256
South Texas Project Risk-Informed GSI-191 Evaluation Volume 2: Probabilistic Risk Analysis RI-GSI191-V02 Revision 1 Table B.3-1 Master Frequency File Used for Point Estimate Event Tree Quantification (Continued)
SF Name Top Event SF Value Split Fraction Description ISF ECCAJ ECC 4.25E-03 ECA=S, ECB=F, ECH C RUN EC217 ECCAK ECC 1.52E-03 ECA=F, ECB=S, ECH C RUN EC215 ECCAL ECC 3.98E-02 ECA=F, ECB=F, ECH C RUN EC309 ECCAM ECC 1.28E-02 ECH A OFF, ECH B RUN, ECH C R/S EC106 ECCAN ECC 1.44E-02 ECA=S, ECB=F, ECH C R/S EC218 ECCAO ECC 1.75E-02 ECA=F, ECB=S, ECH C R/S EC216 ECCAP ECC 5.53E-02 ECA=F, ECB=F, ECH C R/S EC310 ECCAQ ECC 1.37E-03 ECH A OFF, ECH B R/S, ECH C RUN EC103 ECCAR ECC 1.56E-03 ECA=S, ECB=F, ECH C RUN EC219 ECCAS ECC 1.52E-03 ECA=F, ECB=S, ECH C RUN EC215 ECCAT ECC 4.89E-03 ECA=F, ECB=F, ECH C RUN EC311 ECCAU ECC 1.28E-02 ECH A OFF, ECH B R/S, ECH C R/S ECCCJ ECCAV ECC 1.73E-02 ECA=S, ECB=F, ECH C R/S EC220 ECCAW ECC 1.65E-02 ECA=F, ECB=S, ECH C R/S EC216 ECCAX ECC 8.04E-02 ECA=F, ECB=F, ECH C R/S EC312 ECCB ECC 1.67E-02 ECA=S, ECB=F, ECH C OFF EC221 ECCBA ECC 1.37E-03 ECH A RUN, ECH C RUN, ECB=B EC103 ECCBB ECC 3.66E-03 ECA=F, ECH C RUN, ECB=B EC209 ECCBC ECC 1.29E-02 ECH A RUN, ECH C R/S, ECB=B EC106 ECCBD ECC 1.52E-02 ECA=F, ECH C R/S, ECB=B EC210 ECCBE ECC 1.37E-03 ECH A R/S, ECH C RUN, ECB=B EC103 ECCBF ECC 1.61E-03 ECA=F, ECH C RUN, ECB=B EC211 ECCBG ECC 1.28E-02 ECH A R/S, ECH C R/S, ECB=B EC106 ECCBH ECC 1.84E-02 ECA=F, ECH C R/S, ECB=B EC212 ECCBI ECC 1.53E-02 ECH A RUN, ECH C OFF, ECB=B EC109 ECCBJ ECC 1.76E-02 ECA=F, ECH C OFF, ECB=B EC213 ECCBK ECC 1.53E-02 ECH A R/S, ECH C OFF, ECB=B EC109 Page 180 of 256
South Texas Project Risk-Informed GSI-191 Evaluation Volume 2: Probabilistic Risk Analysis RI-GSI 19 1 -V02 Revision I Table B.3-1 Master Frequency File Used for Point Estimate Event Tree Quantification (Continued)
SF Name Top Event SF Value Split Fraction Description ISF ECCBL ECC 2.08E-02 ECA=F, ECH C OFF, ECB=B EC214 ECCBM ECC 1.37E-03 ECH A OFF, ECH C RUN, ECB=B EC103 ECCBN ECC 1.58E-03 ECA=F, ECH C RUN, ECB=B EC215 ECCBO ECC 1.28E-02 ECH A OFF, ECH C R/S, ECB=B EC106 ECCBP ECC 1.76E-02 ECA=F, ECH C R/S, ECB=B EC216 ECCBQ ECC 1.37E-03 ECH B RUN, ECH C EUN, ECA=B EC103 ECCBR ECC 3.64E-03 ECB=F, ECH C RUN, ECA=B EC217 ECCBS ECC 1.29E-02 ECH B RUN, ECH C R/S, ECA=B EC106 ECCBT ECC 1.52E-02 ECB=F, ECH C R/S, ECA=B EC218 ECCBU ECC 1.37E-03 ECH B R/S, ECH C RUN, ECA=B EC103 ECCBV ECC 1.63E-03 ECB=F, ECH C RUN, ECA=B EC219 ECCBW ECC 1.28E-02 ECH B R/S, ECH C R/S, ECA=B EC106 ECCBX ECC 1.86E-02 ECB=F, ECH C R/S, ECA=B EC220 ECCC ECC 1.69E-02 ECA=F, ECB=S, ECH C OFF EC213 ECCCA ECC 1.53E-02 ECH B RUN, ECH C OFF, ECA=B EC109 ECCCB ECC 1.74E-02 ECB=F, ECH C OFF, ECA=B EC221 ECCCC ECC 1.53E-02 ECH B R/S, ECH C OFF, ECA=F EC109 ECCCD ECC 2.08E-02 ECB=F, ECH C OFF, ECA=B EC222 ECCCE ECC 1.37E-03 ECH B OFF, ECH C RUN, ECA=B EC103 ECCCF ECC 1.60E-03 ECB=F, ECH C RUN, ECA=B EC223 ECCCG ECC 1.28E-02 ECH B OFF, ECH C R/S, ECA=B EC106 ECCCH ECC 1.78E-02 ECB=F, ECH C R/S, ECA=B EC224 ECCCI ECC 1.37E-03 ECH TRAIN C RUN EC103 ECCCJ ECC 1.29E-02 ECH TRAIN C R/S EC106 ECCCK ECC 1.53E-02 ECH TRAIN C OFF EC109 ECCD ECC 1.92E-01 ECA=F, ECB=F, ECH C OFF EC301 ECCE ECC 1.53E-02 ECH A RUN, ECH B R/S, ECH C OFF EC109 Page 181 of 256
South Texas Project Risk-Informed GSI-191 Evaluation Volume 2: Probabilistic Risk Analysis RI-GS1191 -V02 Revision I Table B.3-1 Master Frequency File Used for Point Estimate Event Tree Quantification (Continued)
SF Name Top Event SF Value Split Fraction Description ISF ECCF ECC 2.07E-02 ECA=S, ECB=F, ECH C OFF EC222 ECCG ECC 1.69E-02 ECA=F, ECB=S, ECH C OFF EC213 ECCH ECC 6.27E-02 ECA=F, ECB=F, ECH C OFF EC302 ECCI ECC 1.53E-02 ECH A R/S, ECH B RUN, ECH C OFF EC109 ECCJ ECC 1.67E-02 ECA=S, ECB=F, ECH C OFF EC221 ECCK ECC 2.08E-02 ECA=F, ECB=S, ECH C OFF EC214 ECCL ECC 6.31E-02 ECA=F, ECB=F, ECH C OFF EC303 ECCM ECC 1.52E-02 ECH A R/S, ECH B R/S, ECH C OFF EC109 ECCN ECC 1.94E-02 ECA=S, ECB=F, ECH C OFF EC222 ECCO ECC 1.95E-02 ECA=F, ECB=S, ECH C OFF EC214 ECCP ECC 9.21 E-02 ECA=F, ECB=F, ECH C OFF EC304 ECCQ ECC 1.37E-03 ECH A RUN, ECH B OFF, ECH C RUN EC103 ECCR ECC 1.54E-03 ECA=S, ECB=F, ECH C RUN EC223 ECCS ECC 3.02E-03 ECA=F, ECB=S, ECH C RUN EC209 ECCT ECC 3.97E-02 ECA=F, ECB=F, ECH C RUN EC305 ECCU ECC 1.28E-02 ECH A RUN, ECH B OFF, ECH C R/S EC106 ECCV ECC 1.78E-02 ECA=S, ECB=F, ECH C R/S EC224 ECCW ECC 1.45E-02 ECA=F, ECB=S, ECH C R/S EC210 ECCX ECC 5.50E-02 ECA=F, ECB=F, ECH C R/S EC306 ECCY ECC 0.OOE+00 GS ECCZ ECC 1.00E+00 GF ECD EC 1.58E-02 EA=S, EB=F, EC-S EP4BC1 ECE EC 1.52E-02 EA=F, EB=S, EC-S EP4AC1 ECF EC 5.97E-02 EA=F, EB=F, EC-S EPABC1 ECG EC 9.14E-03 BUS ElC - LOOP, EA=O, EC=O(1)
EP4C1 ECH EC 3.64E-02 EA=S, EB=F, EC-O(1)
EP4BC2 ECI EC 2.04E-02 EA=F, EB=S, EC-O(1)
EP4AC2 Page 182 of 256
South Texas Project Risk-Informed GSI-191 Evaluation Volume 2: Probabilistic Risk Analysis RI-GSI 191 -V02 Revision I Table B.3-1 Master Frequency File Used for Point Estimate Event Tree Quantification (Continued)
SF Name Top Event SF Value Split Fraction Description ISF ECJ EC 7.83E-02 EA=F, EB=F, EC-O(1)
EPABC2 ECK EC 9.14E-03 BUS EIC - LOOP, EA-O, EC-O(2)
EP4C1 ECL EC 3.64E-02 EA=S, EB=F, EC-O(2)
EP4BC2 ECM EC 2.08E-02 EA=F, EB=S, EC-O(2)
EP4AC3 ECN EC 8.02E-02 EA=F, EB=F, EC-O(2)
EPABC3 ECO EC 9.13E-03 BUS E1C - LOOP, EB-O, EC-O EP4C1 ECP EC 2.20E-02 EA=S, EB=F, EC-O EP4BC3 ECQ EC 3.58E-02 EA=F, EB=S, EC-O EP4AC4 ECR EC 7.78E-02 EA=F, EB=F, EC-O EPABC4 ECS EC 3.69E-03 EB=B, E1A-O, E1C-S EP4C2 ECT EC 1.62E-02 EB=B, EA=F, E1C-S EP4AC1 ECU EC 9.24E-03 EB=B, E1A-O(1), E1C-O EP4C1 ECV EC 2.13E-02 EB=B, EA=F, ElC-O EP4AC2 ECW EC 9.24E-03 EB=B, E1A-O, ELC-O(2)
EP4C1 ECW101 ECWS 2.86E-04 ECW TRAIN A (WA) - RUN ECW102 ECWS 2.87E-04 ECW TRAIN B (WB) - RUN ECW103 ECWS 2.87E-04 ECW TRAIN C (WC) - RUN ECW1 04 ECWS 1.36E-03 ECW TRAIN A - R/S (LOOP)
ECW105 ECWS 1.36E-03 ECW TRAIN B - R/S (LOOP)
ECW1 06 ECWS 1.35E-03 ECW TRAIN C - R/S (LOOP)
ECW107 ECWS 2.59E-03 ECW TRAIN A - START ECW108 ECWS 2.59E-03 ECW TRAIN B - START ECW109 ECWS 2.58E-03 ECW TRAIN C - START ECW201 ECWS 3.49E-07 WA RUN, WB RUN, WC=B ECW202 ECWS 6.39E-07 WA RUN, WB R/S, WC=B ECW203 ECWS 6.46E-07 WA R/S, WB RUN, WC=B ECW204 ECWS 1.37E-05 WA R/S, WB R/S, WC=B Page 183 of 256
South Texas Project Risk-Informed GSI-191 Evaluation Volume 2: Probabilistic Risk Analysis RI-GSI 191 -V02 Revision 1 Table B.3-1 Master Frequency File Used for Point Estimate Event Tree Quantification (Continued)
SF Name Top Event SF Value Split Fraction Description ISF ECW205 ECWS 1.01E-06 WA RUN, WB START, WC=B ECW206 ECWS 1.51E-05 WA R/S, WB START, WC=B ECW207 ECWS 1.02E-06 WA START, WB RUN, WC=B ECW208 ECWS 1.51E-05 WA START, WB R/S, WC=B ECW209 ECWS 3.42E-07 WA RUN, WC RUN, WB=B ECW210 ECWS 6.63E-07 WA RUN, WC RIS, WB=B ECW211 ECWS 6.72E-07 WA R/S, WC RUN, WB=B ECW212 ECWS 1.33E-05 WA R/S, WC R/S, WB=B ECW213 ECWS 1.02E-06 WA RUN, WC START, WB=B ECW214 ECWS 1.47E-05 WA R/S, WC START, WB=B ECW215 ECWS 1.02E-06 WA START, WC RUN, WB=B ECW216 ECWS 1.49E-05 WA START, WC R/S, WB=B ECW217 ECWS 3.46E-07 WB RUN, WC RUN, WA=B ECW218 ECWS 6.56E-07 WB RUN, WC R/S, WA=B ECW219 ECWS 6.50E-07 WB R/S, WC RUN, WA=B ECW220 ECWS 1.33E-05 WB R/S, WC R/S, WA=B ECW221 ECWS 1.01 E-06 WB RUN, WC START, WA=B ECW222 ECWS 1.44E-05 WB R/S, WC START, WA=B ECW223 ECWS 1.01 E-06 WB START, WC RUN, WA=B ECW224 ECWS 1.46E-05 WB START, WC R/S, WB=B ECW301 ECWS 2.88E-08 WA RUN, WB RUN, WC START ECW302 ECWS 3.27E-08 WA RUN, WB R/S, WC START ECW303 ECWS 3.43E-08 WA R/S, WB RUN, WC START ECW304 ECWS 3.27E-06 WA R/S, WB R/S, WC START ECW305 ECWS 2.96E-08 WA RUN, WC RUN, WB START ECW306 ECWS 3.44E-08 WA RUN, WC R/S, WB START ECW307 ECWS 3.35E-08 WA R/S, WC RUN, WB START Page 184 of 256
South Texas Project Risk-Informed GSI-191 Evaluation Volume 2: Probabilistic Risk Analysis RI-GSI191-V02 Revision I Table B.3-1 Master Frequency File Used for Point Estimate Event Tree Quantification (Continued)
SF Name Top Event SF Value Split Fraction Description ISF ECW308 ECWS 3.29E-06 WA R/S, WC R/S, WB START ECW309 ECWS 2.91E-08 WB RUN, WC RUN, WA START ECW310 ECWS 3.34E-08 WB RUN, WC R/S, WA START ECW311 ECWS 3.29E-08 WB R/S, WC RUN, WA START ECW312 ECWS 3.36E-06 WB R/S, WC R/S, WA START ECX EC 2.18E-02 EB=B, EA=F, ELC-O(2)
EP4AC3 ECY EC O.OOE+00 GS ECZ EC 1.OOE+00 GF EP4A1 EP4KV 8.53E-03 E1A-O - LOOP EP4A2 EP4KV 3.79E-03 E1A-S - LOOP EP4AB1 EP4KV 1.82E-04 E1A-O, E1B-O - LOOP EP4AB2 EP4KV 1.39E-04 E1A-O, E1B-S - LOOP EP4AB3 EP4KV 1.38E-04 EIA-S, E1B-O - LOOP EP4AC1 EP4KV 1.38E-04 E1A-O, E1C-S - LOOP EP4AC2 EP4KV 1.82E-04 EIA-O, E1C-O (1) - LOOP EP4AC3 EP4KV 1.86E-04 E1A-O, E1C-O (2) - LOOP EP4AC4 EP4KV 1.42E-04 E1A-S, ElC-O - LOOP EP4B1 EP4KV 8.19E-03 E1B-O - LOOP EP4B2 EP4KV 3.78E-03 E1B-S - LOOP EP4BC1 EP4KV 1.38E-04 E1B-O, E1C-S - LOOP EP4BC2 EP4KV 1.44E-04 EIB-S, E1C-O - LOOP EP4BC3 EP4KV 1.88E-04 E 1 B-O, E 1C-O - LOOP EP4C1 EP4KV 9.34E-03 E1C-O - LOOP EP4C2 EP4KV 3.80E-03 E1C-S - LOOP EPABC1 EP4KV 1.08E-05 E1A-O, E1B-O, ElC-S - LOOP EPABC2 EP4KV 1.08E-05 E1A-O, ElC-O (1), E1B-S - LOOP EPABC3 EP4KV 1.11E-05 E1A-O, ElC-O (2), E1B-S - LOOP Page 185 of 256
South Texas Project Risk-Informed GSI-191 Evaluation Volume 2: Probabilistic Risk Analysis RI-GS1191-V02 Revision 1 Table B.3-1 Master Frequency File Used for Point Estimate Event Tree Quantification (Continued)
SF Name Top Event SF Value Split Fraction Description ISF EPABC4 EP4KV 1.08E-05 E1B=O, EIC=O, E1A=S - LOOP EXA EX 4.25E-01 EMERGENCY XFMR FAILURE - AFTER GRID RELATED LOOP EXB EX 3.96E-02 EMERG XFMR - NO LOOP OR PLANT CENTERED OR SWITCHYARD EXY EX O.OOE+00 GS EXZ EX 1.OOE+00 GF F101 EABHV 1.29E-04 TRAIN A - RUN F102 EABHV 1.29E-04 TRAIN B - RUN F103 EABHV 1.32E-04 TRAIN C - RUN F104 EABHV 2.30E-03 TRAIN A - R/S (LOOP)
F105 EABHV 2.29E-03 TRAIN B - R/S (LOOP)
F106 EABHV 2.27E-03 TRAIN C - R/S (LOOP)
F107 EABHV 2.71E-03 TRAIN A - START F108 EABHV 2.67E-03 TRAIN B - START F109 EABHV 2.66E-03 TRAIN C - START F201 EABHV 9.73E-08 FA RUN, FB RUN, FC=B F202 EABHV 3.70E-07 FA RUN, FB R/S, FC=B F203 EABHV 3.76E-07 FA R/S, FB RUN, FC=B F204 EABHV 2.84E-05 FA R/S, FB R/S, FC=B F205 EABHV 4.28E-07 FA RUN, FB START, FC=B F206 EABHV 3.01E-05 FA R/S, FB START, FC=B F207 EABHV 4.30E-07 FA START, FB RUN, FC=B F208 EABHV 2.94E-05 FA START, FB R/S, FC=B F209 EABHV 9.65E-08 FA RUN, FC RUN, FB=B F210 EABHV 3.74E-07 FA RUN, FC R/S, FB=B F211 EABHV 3.82E-07 FA R/S, FC RUN, FB=B F212 EABHV 2.91E-05 FA R/S, FC R/S, FB=B Page 186 of 256
South Texas Project Risk-Informed GSI-191 Evaluation Volume 2: Probabilistic Risk Analysis RI-GSI191-V02 Revision I Table B.3-1 Master Frequency File Used for Point Estimate Event Tree Quantification (Continued)
SF Name Top Event SF Value Split Fraction Description ISF F213 EABHV 4.27E-07 FA RUN, FC START, FB=B F214 EABHV 2.92E-05 FA R/S, FC START, FB=B F215 EABHV 4.28E-07 FA START, FC RUN, FB=B F216 EABHV 2.97E-05 FA START, FC R/S, FB=B F217 EABHV 9.66E-08 FB RUN, FC RUN, FA=B F218 EABHV 3.75E-07 FB RUN, FC R/S, FA=B F219 EABHV 3.77E-07 FB R/S, FC RUN, FA=B F220 EABHV 2.92E-05 FB R/S, FC R/S, FA=B F221 EABHV 4.20E-07 FB RUN, FC START, FA=B F222 EABHV 2.96E-05 FB R/S, FC START, FA=B F223 EABHV 4.32E-07 FB START, FC RUN, FA=B F224 EABHV 2.99E-05 FB START, FC R/S, FA=B F301 EABHV 9.81E-09 FA RUN, FB RUN, FC START F302 EABHV 1.35E-08 FA RUN, FB R/S, FC START F303 EABHV 1.39E-08 FA R/S, FB RUN, FC START F304 EABHV 5.44E-06 FA R/S, FB R/S, FC=START F305 EABHV 9.65E-09 FA RUN, FC RUN, FB START F306 EABHV 1.36E-08 FA RUN, FC R/S, FB START F307 EABHV 1.35E-08 FA R/S, FC RUN, FB START F308 EABHV 5.48E-06 FA R/S, FC R/S, FB START F309 EABHV 1.OOE-08 FB RUN, FC RUN, FA START F310 EABHV 1.42E-08 FB RUN, FC R/S, FA START F311 EABHV 1.36E-08 FB R/S, FC RUN, FA START F312 EABHV 5.58E-06 FB R/S, FC R/S, FA START FAA FA 1.29E-04 FA RUN F101 FAB FA 2.30E-03 FA R/S (LOOP)
F104 FAC FA 2.71E-03 FA START F107 Page 187 of 256
South Texas Project Risk-Informed GSI-191 Evaluation Volume 2: Probabilistic Risk Analysis RI-GSI 191 -V02 Revision 1 Table B.3-1 Master Frequency File Used for Point Estimate Event Tree Quantification (Continued)
SF Name Top Event SF Value Split Fraction Description ISF FAY FA O.OOE+00 GS FAZ FA 1.OOE+00 GF FBA FB 1.29E-04 FA RUN, FB RUN F102 FBB FB 7.55E-04 FA=F, FB RUN F201 FBC FB 2.29E-03 FA RUN, FB R/S F105 FBD FB 2.87E-03 FA=F, FB R/S F202 FBE FB 1.29E-04 FA R/S, FB RUN F102 FBF FB 1.63E-04 FA=F, FB RUN F203 FBG FB 2.26E-03 FA R/S, FB R/S (LOOP)
F105 FBH FB 1.23E-02 FA=F, FB R/S F204 FBI FB 2.67E-03 FA RUN, FB START F1 08 FBJ FB 3.32E-03 FA=F, FB START F205 FBK FB 2.65E-03 FA R/S, FB START F108 FBL FB 1.31E-02 FA=F, FB START F206 FBM FB 1.29E-04 FA START, FB RUN F1 02 FBN FB 1.59E-04 FA=F, FB RUN F207 FBO FB 2.26E-03 FA START, FB R/S F105 FBP FB 1.09E-02 FA=F, FB R/S F208 FBQ FB 1.29E-04 FB RUN F1 02 FBR FB 2.29E-03 FB R/S F1 05 FBS FB 2.67E-03 FB START F1 08 FBY FB 0.OOE+00 GS FBZ FB 1.OOE+00 GF FCA FC 2.66E-03 FA RUN, FB RUN, FC START F109 FCAA FC 1.31 E-04 FA R/S, FB START FC RUN F103 FCAB FC 1.58E-04 FA=S, FB=F, FC RUN F223 FCAC FC 1.62E-04 FA=F, FB=S, FC RUN F211 Page 188 of 256
South Texas Project Risk-Informed GSI-191 Evaluation Volume 2: Probabilistic Risk Analysis RI-GSI191-V02 Revision 1 Table B.3-1 Master Frequency File Used for Point Estimate Event Tree Quantification (Continued)
SF Name Top Event SF Value Split Fraction Description ISF FCAD FC 4.50E-04 FA=F, FB=F, FC RUN F307 FCAE FC 2.22E-03 FA R/S, FB START, FC R/S F106 FCAF FC 9.24E-03 FA=S, FB=F, FC R/S F224 FCAG FC 1.04E-02 FA=F, FB=S, FC R/S F212 FCAH FC 1.82E-01 FA=F, FB=F, FC R/S F308 FCAI FC 1.31E-04 FA START, FB RUN, FC RUN F103 FCAJ FC 6.72E-04 FA=S, FB=F, FC RUN F217 FCAK FC 1.54E-04 FA=F, FB=S, FC RUN F215 FCAL FC 2.33E-02 FA=F, FB=F, FC RUN F309 FCAM FC 2.24E-03 FA START, FB RUN, FC R/S F106 FCAN FC 2.81E-03 FA=S, FB=F, FC R/S F218 FCAO FC 1.1OE-02 FA=F, FB=S, FC R/S F216 FCAP FC 3.29E-02 FA=F, FB=F, FC R/S F31 0 FCAQ FC 1.32E-04 FA START, FB R/S, FC RUN F103 FCAR FC 1.61 E-04 FA=S, FB=F, FC RUN F219 FCAS FC 1.55E-04 FA=F, FB=S, FC RUN F215 FCAT FC 4.63E-04 FA=F, FB=F, FC R/S F311 FCAU FC 2.22E-03 FA START, FB R/S, FC R/S F106 FCAV FC 1.05E-02 FA=S, FB=F, FC R/S F220 FCAW FC 8.99E-03 FA=F, FB=S, FC R/S F216 FCAX FC 1.90E-01 FA=F, FB=F, FC R/S F312 FCB FC 3.18E-03 FA=S, FB=F, FC START F221 FCBA FC 1.32E-04 FB=B, FA RUN, FC RUN F103 FCBB FC 7.49E-04 FB=B, FA=F, FC RUN F209 FCBC FC 2.27E-03 FB=B, FA RUN, FC R/S F106 FCBD FC 2.90E-03 FB=B, FA=F, FC R/S F2 10 FCBE FC 1.32E-04 FB=B, FA R/S, FC RUN F103 Page 189 of 256
South Texas Project Risk-Informed GSI-191 Evaluation Volume 2: Probabilistic Risk Analysis RI-GSI 191 -V02 Revision I Table B.3-1 Master Frequency File Used for Point Estimate Event Tree Quantification (Continued)
SF Name Top Event SF Value Split Fraction Description ISF FCBF FC 1.66E-04 FB=B, FA=F, FC RUN F211 FCBG FC 2.24E-03 FB=B, FA R/S FC R/S F106 FCBH FC 1.27E-02 FB=B, FA=F, FC R/S F212 FCBI FC 2.66E-03 FB=B, FA RUN FC START F109 FCBJ FC 3.31E-03 FB=B, FA=F, FC START F213 FCBK FC 2.63E-03 FB=B, FA R/S, FC START F109 FCBL FC 1.27E-02 FB=B, FA=F, FC START F214 FCBM FC 1.32E-04 FB=B, FA START FC RUN F103 FCBN FC 1.58E-04 FB=B, FA=F, FC RUN F215 FCBO FC 2.24E-03 FB=B, FA START FC R/S F106 FCBP FC 1.10E-02 FB=B, FA=F, FC R/S F216 FCBQ FC 1.32E-04 FA=B, FB RUN, FC RUN F103 FCBR FC 7.48E-04 FA=B, FB=F, FC RUN F217 FCBS FC 2.27E-03 FA=B, FB RUN FC R/S F106 FCBT FC 2.91 E-03 FA=B, FB=F, FC R/S F218 FCBU FC 1.32E-04 FA=B, FB R/S, FC RUN F103 FCBV FC 1.65E-04 FA=B, FB=F, FC RUN F219 FCBW FC 2.24E-03 FA=B, FB R/S FC R/S F106 FCBX FC 1.28E-02 FA=B, FB=F, FC R/S F220 FCC FC 3.24E-03 FA=F, FB=S, FC START F213 FCCA FC 2.66E-03 FA=B, FB RUN, FC START F109 FCCB FC 3.25E-03 FA=B, FB=F, FC START F221 FCCC FC 2.63E-03 FA=B, FB R/S, FC START F109 FCCD FC 1.30E-02 FA=B, FB=F, FC START F222 FCCE FC 1.32E-04 FA=B, FB START, FC RUN F103 FCCF FC 1.61 E-04 FA=B, FB=F, FC RUN F223 FCCG FC 2.24E-03 FA=B, FB START, FC R/S F106 Page 190 of 256
South Texas Project Risk-Informed GSI-191 Evaluation Volume 2: Probabilistic Risk Analysis RI-GSI191-V02 Revision I
-Table B.3-1 Master Frequency File Used for Point Estimate Event Tree Quantification (Continued)
SF Name Top Event SF Value Split Fraction Description ISF FCCH FC 1.12E-02 FA=B, FB=F, FC R/S F224 FCCI FC 1.32E-04 FC RUN F103 FCCJ FC 2.27E-03 FC R/S F106 FCCK FC 2.66E-03 FC START F1 09 FCD FC 1.01 E-01 FA=F, FB=F, FC START F301 FCE FC 2.63E-03 FA RUN, FB R/S, FC START F109 FCF FC 1.30E-02 FA=S, FB=F, FC START F222 FCG FC 3.22E-03 FA=F, FB=S, FC START F213 FCH FC 3.64E-02 FA=F, FB=F, FC START F302 FCl FC 2.63E-03 FA R/S, FB RUN, FC START F109 FCJ FC 3.15E-03 FA=S, FB=F, FC START F221 FCK FC 1.27E-02 FA=F, FB=S, FC START F214 FCL FC 3.71 E-02 FA=F, FB=F, FC START F303 FCM FC 2.61 E-03 FA R/S, FB R/S, FC START F109 FCN FC 1.07E-02 FA=S, FB=F, FC START F222 FCO FC 1.05E-02 FA=F, FB=S, FC RUN F214 FCP FC 1.92E-01 FA=F, FB=F, FC START F304 FCQ FC 1.31 E-04 FA RUN, FB START, FC RUN F103 FCR FC 1.58E-04 FA=S, FB=F, FC RUN F223 FCS FC 6.76E-04 FA=F, FB=S, FC RUN F209 FCT FC 2.25E-02 FA=F, FB=F, FC RUN F305 FCU FC 2.24E-03 FA RUN, FB START, FC R/S F106 FCV FC 1.12E-02 FA=S, FB=F, FC R/S F224 FCW FC 2.81E-03 FA=F, FB=S, FC RUN F210 FCX FC 3.19E-02 FA=F, FB=F, FC RUN F306 FCY FC 0.OOE+00 GS FCZ FC 1.OOE+00 GF Page 191 of 256
South Texas Project Risk-Informed GSI-191 Evaluation Volume 2: Probabilistic Risk Analysis RI-GSI191-V02 Revision 1 Table B.3-1 Master Frequency File Used for Point Estimate Event Tree Quantification (Continued)
SF Name Top Event SF Value Split Fraction Description ISF FLLI FBLK O.OOE+00 CORE FLOW BLOCKAGE LLOCA PUMP STATE I FLL22 FBLK O.OOE+00 CORE FLOW BLOCKAGE LLOCA PUMP STATE 22 FLL26 FBLK O.OOE+00 CORE FLOW BLOCKAGE LLOCA PUMP STATE 26 FLL43 FBLK O.OOE+00 CORE FLOW BLOCKAGE LLOCA PUMP STATE 43 FLL9 FBLK O.OOE+00 CORE FLOW BLOCKAGE LLOCA PUMP STATE 9 FMLI FBLK O.OOE+00 CORE FLOW BLOCKAGE, MLOCA STATE 1 FML22 FBLK O.OOE+00 CORE FLOW BLOCKAGE MLOCA STATE 22 FML26 FBLK O.OOE+00 CORE FLOW BLOCKAGE MLOCA PUMP STATE 26 FML43 FBLK O.OOE+00 CORE FLOW BLOCKAGE MLOCA PUMP STATE 43 FML9 FBLK O.OOE+00 CORE FLOW BLOCKAGE MLOCA STATE 9 FPS1 FPD 1.30E-04 FP Diesel All Pumps FPS2 FPD 4.25E-04 FP Diesels - Two Pumps FPS3 FPD 9.45E-03 FP Diesels - One Pump FWSA FWS 5.OOE-03 MAIN FEEDWATER RESPONSE - ATWS FWSY FWS O.OOE+00 GS FWSZ FWS 1.OOE+00 GF FWY FBLK O.OOE+00 no description entered FWZ FBLK 1.OOE+00 no description entered GlA DGX 2.30E-02 TRAIN A DIESEL GENERATOR G1B DGX 2.29E-02 TRAIN B DIESEL GENERATOR GlC DGX 2.28E-02 TRAIN C DIESEL GENERATOR G2AB DGX 7.14E-04 TRAINS A AND B DIESEL GENERATORS G2AC DGX 7.15E-04 TRAINS A AND C DIESEL GENERATORS G2BC DGX 7.07E-04 TRAINS B AND C DIESEL GENERATORS Page 192 of 256
South Texas Project Risk-Informed GSI-191 Evaluation Volume 2: Probabilistic Risk Analysis RI-GSI 191 -V02 Revision 1 Table B.3-1 Master Frequency File Used for Point Estimate Event Tree Quantification (Continued)
SF Name Top Event SF Value Split Fraction Description ISF G3ABC DGX 8.77E-05 TRAINS A, B, AND C DIESEL GENERATORS GAA GA 2.30E-02 DG 11 FAILS -ALL SUPPORT AVAILABLE GlA GAY GA O.OOE+00 GS GAZ GA 1.OOE+00 GF GBA GB 2.27E-02 DG 12 FAILS - GA=S GIB GBB GB 3.1OE-02 DG 12 FAILS - GA=F G2AB GBC GB 2.29E-02 DG 12 FAILS - GA=B G1B GBY GB O.OOE+00 GS GBZ GB 1.OOE+00 GF GCA GC 2.25E-02 DG 13 FAILS - GA=S, GB=S GlC GCB GC 2.80E-02 DG 13 FAILS - GA=S, GB=F G2BC GCC GC 2.81E-02 DG 13 FAILS - GA=F, GB=S G2AC GCD GC 1.23E-01 DG 13 FAILS - GA=F, GB=F G3ABC GCE GC 2.26E-02 DG 13 FAILS - GA=B, GB=S GlC GCF GC 3.09E-02 DG 13 FAILS - GA=B, GB=F G2BC GCG GC 2.26E-02 DG 13 FAILS - GA=S, GB=B GlC GCH GC 3.11E-02 DG 13 FAILS - GA=F, GB=B G2AC GCI GC 2.28E-02 DG 13 FAILS - GA=B, GB=B GlC GCY GC O.OOE+00 GS GCZ GC 1.OOE+00 GF H3A H3 7.20E-01 NO CCI, NO PREVIOUS BURNS H3C H3 1.OOE+00 BURNS AT LOW CONCENTRATIONS H3D H3 1.OOE+00 BURN IN CAVITY HAA HA 2.55E-03 HHSI TRAIN A - ALL SUPPORT HI1A HAY HA O.OOE+00 GS HAZ HA 1.OOE+00 GF HBA HB 2.50E-03 HHSI TRAIN B - HA=S HI1B Page 193 of 256
South Texas Project Risk-Informed GSI-191 Evaluation Volume 2: Probabilistic Risk Analysis RI-GSI 19 1-V02 Revision 1 Table B.3-1 Master Frequency File Used for Point Estimate Event Tree Quantification (Continued)
SF Name Top Event SF Value Split Fraction Description ISF HBB HB 2.28E-02 HHSI TRAIN B - HA=F HI2AB HBC HB 2.55E-03 HHSI TRAIN B - HA=B HI1B HBY HB 0.OOE+00 GS HBZ HB 1.OOE+00 GF HCA HC 2.43E-03 HHSI TRAIN C - HA=S, HB=S HG1C HCB HC 1.79E-02 HHSI TRAIN C - HA=S, HB=F HI2BC HCC HC 1.78E-02 HHSI TRAIN C - HA=F, HB=S HI2AC HCD HC 2.32E-01 HHSI TRAIN C - HA=F, HB=F HI3ABC HCE HC 2.47E-03 HHSI TRAIN C - HA=B, HB=S Hl1C HCF HC 2.28E-02 HHSI TRAIN C - HA=B, HB=F HI2BC HCG HC 2.47E-03 HHSI TRAIN C - HA=S, HB=B H11C HCH HC 2.27E-02 HHSI TRAIN C - HA=F, HB=B HI2AC HCI HC 2.52E-03 HHSI TRAIN C - HA=B, HB=B H11C HCY HC 0.OOE+00 GS HCZ HC 1.00E+00 GF HEA HE 7.20E-01 RCS PRESS < 200 PSIA @ VB, SPRAYS OPERATING @ VB HEB HE 0.OOE+00 RCS PRESS < 200 PSIA @ VB, SPRAYS UNAVAILABLE HIIA HI 2.55E-03 HHSI TRAIN A HI1B HI 2.55E-03 HHSI TRAIN B H11C HI 2.52E-03 HHSI TRAIN C HI2AB HI 5.81 E-05 HHSI TRAINS A AND B HI2AC HI 5.78E-05 HHSI TRAINS A AND C HI2BC HI 5.81 E-05 HHSI TRAINS B AND C HI3ABC HI 1.35E-05 3 HHSI TRAINS FAIL HIY HI O.OOE+00 GS HIZ HI 1.OOE+00 GF Page 194 of 256
South Texas Project Risk-Informed GSI-191 Evaluation Volume 2: Probabilistic Risk Analysis RI-GS1191-V02 Revision 1 Table B.3-1 Master Frequency File Used for Point Estimate Event Tree Quantification (Continued)
SF Name Top Event SF Value Split Fraction Description ISF HLEG3 HLEG 4.40E-05 ALL SUPPORT AVAILABLE HLEGA HLEG 1.45E-03 TRAIN A HOT LEG RECIRCULATION FAILS HLEGAB HLEG 5.66E-05 TRAIN A,B HOT LEG RECIRCULATION FAILS HLEGAC HLEG 5.67E-05 TRAIN A,C HOT LEG RECIRCULATION FAILS HLEGB HLEG 1.45E-03 TRAIN B HOT LEG RECIRCULATION FAILS HLEGBC HLEG 5.71 E-05 TRAIN B,C HOT LEG RECIRCULATION FAILS HLEGC HLEG 1.45E-03 TRAIN C HOT LEG RECIRCULATION FAILS HLEGY HLEG 0.00E+00 GUARANTEED SUCCESS (GS)
HLEGZ HLEG 1.00E+00 GUARANTEED FALURE (GF)
HMEA HME 0.00E+00 RCS PRESS < 200 PSIA HMEH HME 9.20E-01 RCS PRESS > 600 PSIA @ VB HMEI HME 7.30E-01 200 PSIA < RCS PRESS < 600 PSIA @ VB IAA IA 1.12E-03 ESFAS TRAIN A - GT IG1A lAB IA 6.73E-03 ESFAS TRAIN A - LOCA IS1A IAC IA 5.34E-03 ESFAS TRAIN A - LOSP lO1A IAS1 IAS 3.79E-06 IAS - OFFSITE POWER AVAILABLE - 11, 12 OPER IAS10 IAS 7.86E-05
[AS - MAINT CMPR 14 - 12, 13 OPER IAS1 1 IAS 7.96E-05 IAS - MAINT CMPR 14 -AVG IAS12 IAS 1.57E-03 IAS - CMPR 14 ONLY (RUN), NO LOOP IAS13 IAS 1.32E-02 IAS - CMPR 14 ONLY (START), NO LOOP IAS14 IAS 2.01E-01 IAS - CMPR 14 ONLY, LOOP IAS15 IAS 8.61E-05 IAS - MAINT CMPRS 13 AND 14 IAS16 IAS 8.45E-05 IAS - MAINT CMPRS 12 AND 14 IAS17 IAS 8.06E-06 IAS - MAINT CMPRS 12 AND 13 IAS18 IAS 8.67E-05 IAS-MAINT CMPRS 11 AND 14 IAS19 IAS 8.02E-06 IAS-MAINT CMPRS 11 AND 13 IAS2 IAS 3.81 E-06 IAS-CMPR 11, 13 OPER Page 195 of 256
South Texas Project Risk-Informed GSI-191 Evaluation Volume 2: Probabilistic Risk Analysis RI-GSI191-V02 Revision 1 Table B.3-1 Master Frequency File Used for Point Estimate Event Tree Quantification (Continued)
SF Name Top Event SF Value Split Fraction Description ISF IAS20 IAS 8.02E-06 IAS - MAINT CMPRS 11 AND 12 IAS21 lAS 1.55E-03 IAS - MAINT COMPRS 11, 12, AND 13 IAS22 IAS 1.64E-03 IAS - MAINT COMPRS 11, 12, AND 14 IAS23 IAS 1.63E-03 IAS - MAINT COMPRS 11, 13, AND 14 IAS24 IAS 1.65E-03 IAS - MAINT COMPRS 12, 13, AND 14 IAS3 IAS 3.82E-06 IAS - CMPR 12, 13 OPER IAS4 IAS 3.81E-06 IAS -AVERG IAS1 + IAS2 + IAS3 IAS5 IAS 3.47E-06 IAS - MAINT CMPR 11 IAS6 IAS 3.45E-06 IAS - MAINT CMPR 12 IAS7 IAS 3.46E-06 IAS - MAINT CMPR 13 IAS8 IAS 7.96E-05 IAS - MAINT CMPR 14 - 11, 12 OPER IAS9 IAS 8.04E-05 IAS - MAINT CMPR 14 - 11, 13 OPER IASY IAS O.OOE+00 GS IASZ IAS 1.OOE+00 GF lAY IA O.OOE+00 GS IAZ IA 1.OOE+00 GF IBA IB 1.03E-03 ESFAS TRAIN B - GT - IA=S IG1B IBB IB 5.23E-04 ESFAS TRAIN B - GT - IA=F IG2AB IBC IB 1.02E-03 ESFAS TRAIN B - GT - IA=B IG1B IBD IB 6.72E-03 ESFAS TRAIN B - LOCA - IA=S IS1B IBE IB 7.93E-03 ESFAS TRAIN B - LOCA - IA=F IS2AB IBF IB 6.72E-03 ESFAS TRAIN B - LOCA - IA=B IS11B IBG IB 5.30E-03 ESFAS TRAIN B - LOSP - IA=S IOIB IBH IB 6.26E-03 ESFAS TRAIN B - LOSP - IA=F IO2AB IBI IB 5.31E-03 ESFAS TRAIN B - LOSP - IA=B I10B IBY IB O.OOE+00 GS IBZ IB 1.OOE+00 GF Page 196 of 256
South Texas Project Risk-Informed GSI-191 Evaluation Volume 2: Probabilistic Risk Analysis RI-GSI 191 -V02 Revision 1 Table B.3-1 Master Frequency File Used for Point Estimate Event Tree Quantification (Continued)
SF Name Top Event SF Value Split Fraction Description ISF ICA IC 1.03E-03 ESFAS TRAIN C - GT - IA=S, IB=S IGlC ICAA IC 5.27E-03 ESFAS TRAIN C - LOSP - IA=B, IB=S IOlC ICAB IC 6.33E-03 ESFAS TRAIN C - LOSP - IA=B, IB=F IO2BC ICAC IC 5.27E-03 ESFAS TRAIN C - LOSP - IA=B, IB=B IOlC ICB IC 3.54E-04 ESFAS TRAIN C - GT - IA=S, IB=F IG2BC ICC IC 4.02E-04 ESFAS TRAIN C - GT - IA=F, IB=S IG2AC ICD IC 2.18E-01 ESFAS TRAIN C - GT - IA=F, IB=F IG3ABC ICE IC 1.03E-03 ESFAS TRAIN C - GT - IA=S, IB=B IGlC ICF IC 5.16E-04 ESFAS TRAIN C - GT - IA=F, IB=B IG2AC ICG IC 1.03E-03 ESFAS TRAIN C - GT - IA=B, IB=S IG1 C ICH IC 4.79E-04 ESFAS TRAIN C - GT - IA=B, IB=F IG2BC IC!
IC 1.03E-03 ESFAS TRAIN C - GT IA=B, IB=B IGiC ICJ IC 6.77E-03 ESFAS TRAIN C - LOCA - IA=S, IB=S ISiC ICK IC 7.36E-03 ESFAS TRAIN C - LOCA - IA=S, IB=F IS2BC ICL IC 7.58E-03 ESFAS TRAIN C - LOCA - IA=F, IB=S IS2AC 1CM IC 3.05E-02 ESFAS TRAIN C - LOCA - IA=F, IB=F IS3ABC ICN IC 6.77E-03 ESFAS TRAIN C - LOCA - IA=S, IB=B IS2AC ICO IC 7.76E-03 ESFAS TRAIN C - LOCA - IA=F, IB=B IS2AC ICP IC 6.77E-03 ESFAS TRAIN C - LOCA - IA=B, IB=S ISiC ICQ IC 7.54E-03 ESFAS TRAIN C - LOCA - IA=B, IB=F IS2BC ICR IC 6.78E-03 ESFAS TRAIN C - LOCA - IA=F, IB=F ISiC ICS IC 5.26E-03 ESFAS TRAIN C - LOSP - IA=S, IB=S IOIC ICT IC 6.22E-03 ESFAS TRAIN C - LOSP - IA=S, IB=F IO2BC ICU IC 6.26E-03 ESFAS TRAIN C - LOSP - IA=F, IB=S IO2AC ICV IC 2.36E-02 ESFAS TRAIN C - LOSP - IA=F, IB=F IO3ABC ICW IC 5.26E-03 ESFAS TRAIN C - LOSP - IA=S, IB=B IOlC ICX IC 6.37E-03 ESFAS TRAIN C - LOSP - IA=F, IB=B IO2AC Page 197 of 256
South Texas Project Risk-Informed GSI-191 Evaluation Volume 2: Probabilistic Risk Analysis RI-GSI191-V02 Revision I Table B.3-1 Master Frequency File Used for Point Estimate Event Tree Quantification (Continued)
SF Name Top Event SF Value Split Fraction Description ISF ICY IC 0.OOE+00 GS ICZ IC 1.00E+00 GF IGIA ESFAS 1.12E-03 GT - ESFAS TRAIN A FAILS IGIB ESFAS 1.02E-03 GT - ESFAS TRAIN B FAILS IG1C ESFAS 1.03E-03 GT-ESFAS TRAIN C FAILS IG2AB ESFAS 5.88E-07 GT - ESFAS TRAINS A, B FAIL IG2AC ESFAS 5.80E-07 GT - ESFAS TRAINS A, C FAIL IG2BC ESFAS 4.91 E-07 GT - ESFAS TRAINS B, C FAIL IG3ABC ESFAS 1.28E-07 GT - ESFAS TRAINS A, B, C FAIL INA IN 3.72E-05 ALL SUPPORT INB IN 1.85E-03 LOSS OF SUPPORT TO SFP HX HEADER MOV-0032 (TRAIN B)
INC IN 3.62E-03 LOSS OF SUPPORT SFP HX MOV 0447, OTHER MOV 0236 IND IN 1.83E-03 LOSS OF SUPPORT OTHER MOV 0235 INE IN 3.62E-03 LOSS OF SUPPORT SFP HX MOV 0032, OTHER MOV 0235 INSTA INST 1.56E-09 120V VITAL AC - ALL SUPPORT INSTB INST 3.72E-09 LOSS OF CHANNEL I INSTC INST 3.94E-09 LOSS OF CHANNEL II INSTD INST 3.73E-09 LOSS OF CHANNEL III INSTE INST 3.88E-09 LOSS OF CHANNEL IV INSTF INST 6.71E-08 LOSS OF CHANNELS 1, 11 INSTG INST 6.82E-08 LOSS OF CHANNELS 1, 111 INSTH INST 6.78E-08 LOSS OF CHANNELS I, IV INSTI INST 6.78E-08 LOSS OF CHANNELS II, III INSTJ INST 6.81E-08 LOSS OF CHANNELS II, IV INSTK INST 6.76E-08 LOSS OF CHANNELS III, IV Page 198 of 256
South Texas Project Risk-Informed GSI-191 Evaluation Volume 2: Probabilistic Risk Analysis RI-GSI191-V02 Revision 1 Table B.3-1 Master Frequency File Used for Point Estimate Event Tree Quantification (Continued)
SF Name Top Event SF Value Split Fraction Description ISF INSTL INST 1.35E-04 LOSS OF CHANNELS 1, 11, 111 INSTM INST 1.35E-04 LOSS OF CHANNELS 1, 11, IV INSTN INST 1.37E-04 LOSS OF CHANNELS 1, 111, IV INSTO INST 1.35E-04 LOSS OF CHANNELS II, Ill, IV INY IN 0.OOE+00 GS INZ IN 1.00E+00 GF lO1A ESFAS 5.34E-03 LOOP - TRAIN A FAILS 101B ESFAS 5.31 E-03 LOOP - TRAIN B FAILS IOlC ESFAS 5.27E-03 LOOP - TRAIN C FAILS IO2AB ESFAS 3.34E-05 LOOP - TRAINS A, B FAIL IO2AC ESFAS 3.40E-05 LOOP - TRAINS A, C FAIL IO2BC ESFAS 3.36E-05 LOOP - TRAINS B, C FAIL IO3ABC ESFAS 7.89E-07 LOOP - TRAINS A, B, C FAIL IPA IP 0.OOE+00
- RCS PRESS < 2000 PSIA @ UTAF IPS IP 7.20E-01
- RCS PRESS > 2000 PSIA @ UTAF, NO SEAL LOCA IPX IP 1.50E-01
- RCS PRESS > 2000 PSI, SEAL LOCA ISIA ESFAS 6.73E-03 LOCA - TRAIN A FAILS ISIB ESFAS 6.72E-03 LOCA-TRAIN B FAILS ISiC ESFAS 6.78E-03 LOCA - TRAIN C FAILS IS2AB ESFAS 5.33E-05 LOCA - TRAINS A, B FAIL IS2AC ESFAS 5.22E-05 LOCA - TRAINS A, C FAIL IS2BC ESFAS 5.07E-05 LOCA - ESFAS TRAINS B, C FAIL IS3ABC ESFAS 1.63E-06 LOCA - ESFAS TRAINS A, B, C FAIL ISA IS 0.OOE+00 RCS PRESS < 2000 PSIA @ UTAF ISS IS 6.33E-02 RCS PRESS > 2000 PSIA @ UTAF, NO SORV OR SEAL LOCA ISX IS 2.29E-01 RCS PRESS > 2000 PSI, SEAL LOCA Page 199 of 256
South Texas Project Risk-Informed GSI-191 Evaluation Volume 2: Probabilistic Risk Analysis RI-GSI191-V02 Revision I Table B.3-1 Master Frequency File Used for Point Estimate Event Tree Quantification (Continued)
SF Name Top Event SF Value Split Fraction Description ISF ISY IS 3.92E-02 STUCK OPEN SRV OR PORV IVO INST 1.50E-09 NO INVERTER MAINT IVi INST 1.01E-13 IV1201 INVERTER MAINT IV12 INST 1.79E-12 IV1201 INVERTER MAINT-CH II=F IV123 INST 3.53E-09 IV1201 INVERTER MAINT-CH I, II=F IV1234 INST 2.66E-05 IV1201 INVERTER MAINT - CH II, Ill, IV=F IV124 INST 3.54E-09 IV1201 INVERTER MAINT - CH II, IV=F IV13 INST 1.77E-12 IV1201 INVERTER MAINT-CH III=F IV134 INST 3.62E-09 IV1201 INVERTER MAINT - CH III, IV=F IV14 INST 1.70E-12 IV1201 INVERTER MAINT-CH IV=F IV2 INST 1.03E-13 IV1202 INVERTER MAINT IV21 INST 1.76E-12 IV1202 INVERTER MAINT - CH I=F IV213 INST 3.55E-09 IV1202 INVERTER MAINT - CH I, III=F IV2134 INST 2.57E-05 IV1202 INVERTER MAINT - CH I, IIl, IV=F IV214 INST 3.50E-09 IV1202 INVERTER MAINT - CH I, IV=F IV23 INST 1.80E-12 IV1202 INVERTER MAINT-CH 1II=F IV234 INST 3.58E-09 IV1202 INVERTER MAINT - CH III, IV=F IV24 INST 1.81E-12 IV1202 INVERTER MAINT-CH IV=F IV3 INST 1.06E-13 IV1203 INVERTER MAINT IV31 INST 1.80E-12 IV1203 INVERTER MAINT - CH I=F IV312 INST 3.56E-09 IV1203 INVERTER MAINT - CH I, II=F IV3124 INST 2.68E-05 IV1203 INVERTER MAINT - CH I, 1l, IV=F IV314 INST 3.60E-09 IV1203 INVERTER MAINT - CH I, IV=F IV32 INST 1.72E-12 IV1203 INVERTER MAINT - CH II=F IV324 INST 3.47E-09 IV1203 INVERTER MAINT - CH II, IV=F IV34 INST 1.79E-12 IV1203 INVERTER MAINT - CH IV=F IV4 INST 1.09E-13 IV1204 INVERTER MAINT Page 200 of 256
South Texas Project Risk-Informed GSI-191 Evaluation Volume 2: Probabilistic Risk Analysis RI-GSI191-V02 Revision I Table B.3-1 Master Frequency File Used for Point Estimate Event Tree Quantification (Continued)
SF Name Top Event SF Value Split Fraction Description ISF IV41 INST 1.84E-12 IV1204 INVERTER MAINT-CH I=F IV412 INST 3.56E-09 IV1204 INVERTER MAINT - CH I, 11=F IV4123 INST 2.57E-05 IV1204 INVERTER MAINT - CH 1, 11, 111=F IV413 INST 3.58E-09 IV1204 INVERTER MAINT - CH I, 111=F IV42 INST 1.76E-12 IV1204 INVERTER MAINT - CH 11=F IV423 INST 3.53E-09 IV1204 INVERTER MAINT - CH II, 1I1=F IV43 INST 1.78E-12 IV1204 INVERTER MAINT - CH 1I1=F IXR ESFAS 1.70E-06 LOSS OF SSPS TRAIN R - LOCA IXS ESFAS 1.68E-06 LOSS OF SSPS TRAIN S - LOCA KAA KA 2.43E-04 KA - RUN CCW101 KAB KA 9.69E-03 KA - R/S CCW104 KAC KA 9.60E-03 KA - STBY CCW107 KAD KA 1.03E-02 KA -START CCWi 10 KAY KA O.OOE+00 GS KAZ KA 1.OOE+00 GF KBA KB 9.62E-03 KA RUN, KB STBY CCW108 KBB KB 1.23E-02 KA=F, KB STBY CCW201 KBC KB 9.54E-03 KA R/S, KB STBY CCW108 KBD KB 1.78E-02 KA=F, KB STBY CCW202 KBE KB 1.02E-02 KA RUN, KB START CCW111 KBF KB 1.29E-02 KA=F, KB START CCW203 KBG KB 1.02E-02 KA R/S, KB START CCW111 KBH KB 1.85E-02 KA=F, KB START CCW204 KBI KB 2.39E-04 KA STBY, KB RUN CCW102 KBJ KB 3.06E-04 KA=F, KB RUN CCW205 KBK KB 9.62E-03 KA STBY, KB R/S CCW105 KBL KB 1.81E-02 KA=F, KB R/S CCW206 Page 201 of 256
South Texas Project Risk-Informed GSI-191 Evaluation Volume 2: Probabilistic Risk Analysis RI-GSI191-V02 Revision 1 Table B.3-1 Master Frequency File Used for Point Estimate Event Tree Quantification (Continued)
SF Name Top Event SF Value Split Fraction Description ISF KBM KB 2.39E-04 KA START, KB RUN CCW102 KBN KB 3.05E-04 KA=F, KB RUN CCW207 KBO KB 9.62E-03 KA START, KB R/S CCW105 KBP KB 1.73E-02 KA=F, KB R/S CCW208 KBQ KB 1.02E-02 KA STBY, KB START CCW1 11 KBR KB 1.89E-02 KA=F, KB START CCW209 KBS KB 9.54E-03 KA START, KB STBY CCW108 KBT KB 1.74E-02 KA=F, KB STBY CCW210 KBU KB 2.40E-04 KB - RUN CCW102 KBV KB 9.70E-03 KB - RESTART (R/S)
CCW105 KBW KB 9.62E-03 KB - STANDBY (STBY)
CCW108 KBX KB 1.02E-02 KB - START CCW111 KBY KB O.OOE+00 GS KBZ KB 1.OOE+00 GF KCA KC 1.02E-02 KA RUN, KB STBY, KC START CCW112 KCAA KC 9.59E-03 KA START, KB RUN, KC STBY CCW109 KCAB KC 1.01E-02 KA=S, KB=F, KC STBY CCW221 KCAC KC 1.75E-02 KA=F, KB=S, KC STBY CCW220 KCAD KC 1.87E-01 KA=F, KB=F, KC STBY CCW307 KCAE KC 9.54E-03 KA START, KB R/S, KC STBY CCW109 KCAF KC 1.53E-02 KA=S, KB=F, KC STBY CCW222 KCAG KC 1.53E-02 KA=F, KB=S, KC STBY CCW220 KCAH KC 1.45E-01 KA=F, KB=F, KC STBY CCW308 KCAI KC 2.41E-04 KA STBY, KB START, KC RUN CCW103 KCAJ KC 2.52E-04 KA=S, KB=F, KC RUN CCW227 KCAK KC 2.49E-04 KA=F, KB=S, KC RUN CCW215 KCAL KC 3.37E-03 KA=F, KB=F, KC RUN CCW309 Page 202 of 256
South Texas Project Risk-Informed GSI-191 Evaluation Volume 2: Probabilistic Risk Analysis RI-GSI 191 -V02 Revision 1 Table B.3-1 Master Frequency File Used for Point Estimate Event Tree Quantification (Continued)
SF Name Top Event SF Value Split Fraction Description ISF KCAM KC 9.40E-03 KA STBY, KB START, KC R/S CCW106 KCAN KC 1.51E-02 KA=S, KB=F, KC R/S CCW228 KCAO KC 1.56E-02 KA=F, KB=S, KC R/S CCW216 KCAP KC 1.43E-01 KA=F, KB=F, KC R/S CCW310 KCAQ KC 2.41E-04 KA START, KB STBY, KC RUN CCW103 KCAR KC 2.56E-04 KA=S, KB=F, KC RUN CCW225 KCAS KC 2.56E-04 KA=F, KB=S, KC RUN CCW217 KCAT KC 3.26E-03 KA=F, KB=F, KC RUN CCW311 KCAU KC 9.40E-03 KA START, KB STBY, KC R/S CCW106 KCAV KC 1.57E-02 KA=S, KB=F, KC R/S CCW226 KCAW KC 1.52E-02 KA=F, KB=S, KC R/S CCW218 KCAX KC 1.41E-01 KA=F, KB=F, KC RPS CCW312 KCB KC 1.86E-02 KA=S, KB=F, KC START CCW229 KCBA KC 9.67E-03 KA RUN, KB=B, KC STBY CCW109 KCBB KC 1.24E-02 KA=F, KB=B, KC STBY CCW211 KCBC KC 9.59E-03 KA R/S, KB=B, KC STBY CCW109 KCBD KC 1.79E-02 KA=F, KB=B, KC STBY CCW212 KCBE KC 1.03E-02 KA RUN, KB=B, KC START CCW112 KCBF KC 1.30E-02 KA=F, KB=B, KC START CCW213 KCBG KC 1.02E-02 KA R/S, KB=B, KC START CCW112 KCBH KC 1.87E-02 KA=F, KB=B, KC START CCW214 KCBI KC 2.41 E-04 KA STBY, KB=B, KC RUN CCW103 KCBJ KC 3.08E-04 KA=F, KB=B, KC RUN CCW215 KCBK KC 9.46E-03 KA STBY, KB=B, KC R/S CCW106 KCBL KC 1.80E-02 KA=F, KB=B, KC R/S CCW216 KCBM KC 2.41E-04 KA START, KB=B, KC RUN CCW103 KCBN KC 3.09E-04 KA=F, KB=B, KC RUN CCW217 Page 203 of 256
South Texas Project Risk-Informed GSI-191 Evaluation Volume 2: Probabilistic Risk Analysis RI-GSI191-V02 Revision I Table B.3-1 Master Frequency File Used for Point Estimate Event Tree Quantification (Continued)
SF Name Top Event SF Value Split Fraction Description ISF KCBO KC 9.46E-03 KA START, KB=B, KC R/S CCW106 KCBP KC 1.74E-02 KA=F, KB=B, KC R/S CCW218 KCBQ KC 1.02E-02 KA STBY, KB=B, KC START CCW112 KCBR KC 1.88E-02 KA=F, KB=B, KC START CCW219 KCBS KC 9.59E-03 KA START, KB=B, KC STBY CCW109 KCBT KC 1.75E-02 KA=F, KB=B, KC STBY CCW220 KCBU KC 9.67E-03 KA=B, KB RUN, KC STBY CCW109 KCBV KC 1.24E-02 KA=B, KB=F, KC STBY CCW221 KCBW KC 9.59E-03 KA=B, KB R/S, KC STBY CCW109 KCBX KC 1.77E-02 KA=B, KB=F, KC STBY CCW222 KCC KC 1.07E-02 KA=F, KB=S, KC START CCW213 KCCA KC 1.03E-02 KA=B, KB RUN, KC START CCW112 KCCB KC 1.30E-02 KA=B, KB=F, KC START CCW223 KCCC KC 1.02E-02 KA=B, KB R/S, KC START CCW112 KCCD KC 1.84E-02 KA=B, KB=F, KC START CCW224 KCCE KC 2.41 E-04 KA=B, KB STBY, KC RUN CCW103 KCCF KC 3.12E-04 KA=B, KB=F, KC RUN CCW225 KCCG KC 9.46E-03 KA=B, KB STBY, KC R/S CCW1 06 KCCH KC 1.80E-02 KA=B, KB=F, KC R/S CCW226 KCCI KC 2.41 E-04 KA=B, KC START, KC RUN CCW103 KCCJ KC 3.07E-04 KA=B, KB=F, KC RUN CCW227 KCCK KC 9.46E-03 KA=B, KB START, KC R/S CCW106 KCCL KC 1.74E-02 KA=B, KB=F, KC R/S CCW228 KCCM KC 1.02E-02 KA=B, KB STBY, KC START CCW112 KCCN KC 1.86E-02 KA=B, KB=F, KC START CCW229 KCCO KC 9.59E-03 KA=B, KB START, KC STBY CCW1 09 KCCP KC 1.75E-02 KA=B, KB=F, KC STBY CCW230 Page 204 of 256
South Texas Project Risk-Informed GSI-191 Evaluation Volume 2: Probabilistic Risk Analysis RI-GSI191-V02 Revision 1 Table B.3-1 Master Frequency File Used for Point Estimate Event Tree Quantification (Continued)
SF Name Top Event SF Value Split Fraction Description ISF KCCQ KC 2.42E-04 KC - RUN CCW1 03 KCCR KC 9.54E-03 KC - RESTART (R/S)
CCW106 KCCS KC 9.67E-03 KC - STANDBY (STBY)
CCW1 09 KCCT KC 1.03E-02 KC - START CCW112 KCD KC 2.02E-01 KA=F, KB=F, KC START CCW301 KCE KC 1.02E-02 KA R/S, KB STBY, KC START CCW112 KCF KC 1.63E-02 KA=S, KB=F, KC START CCW229 KCG KC 1.63E-02 KA=F, KB=S, KC START CCW214 KCH KC 1.48E-01 KA=F, KB=F, KC START CCW302 KCI KC 9.59E-03 KA RUN, KB START, KC STBY CCW109 KCJ KC 1.74E-02 KA=S, KB=F, KC STBY CCW230 KCK KC 1.01E-02 KA=F, KB=S, KC STBY CCW211 KCL KC 1.87E-01 KA=F, KB=F, KC STBY CCW303 KCM KC 9.53E-03 KA R/S, KB START, KC STBY CCW109 KCN KC 1.52E-02 KA=S, KB=F, KC STBY CCW230 KCO KC 1.56E-02 KA=F, KB=S, KC STBY CCW212 KCP KC 1.44E-01 KA=F, KB=F, KC STBY CCW304 KCQ KC 1.02E-02 KA STBY, KB RUN, KC START CGW112 KCR KC 1.06E-02 KA=S, KB=F, KC START CCW223 KCS KC 1.88E-02 KA=F, KB=S, KC START CCW219 KCT KC 2.02E-01 KA=F, KB=F, KC START CCW305 KCU KC 1.02E-02 KA STBY, KB R/S, KC START CCW112 KCV KC 1.61 E-02 KA=S, KB=F, KC START CCW224 KCW KC 1.65E-02 KA=F, KB=S, KC START CCW219 KCX KC 1.47E-01 KA=F, KB=F, KC START CCW306 KCY KC O.OOE+00 GS KCZ KC 1.OOE+00 GF Page 205 of 256
South Texas Project Risk-Informed GSI-191 Evaluation Volume 2: Probabilistic Risk Analysis RI-GSI191-V02 Revision I Table B.3-1 Master Frequency File Used for Point Estimate Event Tree Quantification (Continued)
SF Name Top Event SF Value Split Fraction Description ISF L1A Li O.OOE+00 NO LARGE ISOLATION FAIL PRIOR TO CORE DAMAGE LIB Li 1.OOE+00 LARGE ISOLATION FAILURE L2A L2 3.85E-02
- RCS PRESS < 200 PSIA @ VB L2B L2 3.85E-02
- NO HPME, 200 < RCS PRESS < 600 PSIA @ VB L2C L2 3.85E-02
- HPME, 200 < RCS PRESS < 600 PSIA @ VB, NO C2C WATER IN CAVITY, NO CHR L2D L2 3.85E-02
- HPME, 200 < RCS PRESS < 600 PSIA @ VB, NO C2D WATER IN CAVITY, NO CHR L2E L2 3.85E-02
- HPME, 200 < RCS PRESS < 600 PSIA @ VB, C2E WATER IN CAVITY L21 L2 3.85E-02
- HPME, 600 < RCS PRESS < 2000 PSIA @ VB, C21 WATER IN CAVITY L2J L2 3.85E-02
- HPME, 600 < RCS PRESS < 2000 PSIA @ VB, C2J NO WATER IN CAVITY L2K L2 3.85E-02
- HPME, 600 < RCS PRESS < 2000 PSIA @ VB, C2K NO SPRAYS OR CHR L2L L2 3.85E-02
- NO HPME, 600 < RCS PRESS < 2000 PSIA @
VB, L2R L2 9.09E-01
- HPME, RCS PRESS > 2000 PSIA @ VB, WATER C2R IN CAVITY, SPRAYS, CHR L2S L2 9.09E-01
- HPME, RCS PRESS > 2000 PSIA @ VB, NO C2S WATER IN CAVITY, NO SPRAYS, CHR L2T L2 9.09E-01
- HPME, RCS PRESS > 200 PSIA @ VB, NO C2T SPRAYS OR CHRO L2U L2 1.OOE+00
- NO HPME, ROCKET MODEL FAILURE, RCS C2U PRESS > 2000 PSIA @ VB L41 L4 1.OOE+00 LARGE, LATE CONTAINMENT FAILURE L4A L4 1.OOE-02
- NO LONG TERM CHR L4B L4 0.OOE+00
- LONG TERM CHR AVAILABLE LAA LA 4.51E-03 LHSI TRAIN A -ALL SUPPORT LHIA LAY LA 0.OOE+00 GS Page 206 of 256
South Texas Project Risk-Informed GSI-191 Evaluation Volume 2: Probabilistic Risk Analysis RI-GSI191-V02 Revision 1 Table B.3-1 Master Frequency File Used for Point Estimate Event Tree Quantification (Continued)
SF Name Top Event SF Value Split Fraction Description ISF LAZ LA 1.OOE+00 GF LBA LB 4.45E-03 LHSI TRAIN B - LA=S LHIB LBB LB 1.41E-02 LHSI TRAIN B - LA=F LHIAB LBC LB 4.50E-03 LHSI TRAIN B - LA=B LHIB LBY LB O.OOE+00 GS LBYA LBY 1.OOE+00 RHR/LHSI INTERFACING LOCA LBYB LBY O.OOE+00 NO LARGE BYPASS LBZ LB 1.OOE+00 GF LCA LC 4.37E-03 LHSI TRAIN C - LA=S, LB=S LHIC LCB LC 1.25E-02 LHSI TRAIN C - LA=S, LB=F LHIBC LCC LC 1.22E-02 LHSI TRAIN C - LA=F, LB=S LHIAC LCD LC 1.54E-01 LHSI TRAIN C - LA=F, LB=F LHIABC LCE LC 4.40E-03 LHSI TRAIN C - LA=B, LB=S LHIC LCF LC 1.45E-02 LHSI TRAIN C - LA=B, LB=F LHIBC LCG LC 4.40E-03 LHSI TRAIN C - LA=S, LB=B LHIC LCH LC 1.42E-02 LHSI TRAIN C - LA=F, LB=B LHIAC LCI LC 4.45E-03 LHSI TRAIN C - LA=B, LB=B LHIC LCY LC O.OOE+00 GS LCZ LC 1.OOE+00 GF LHIA LHSI 4.51 E-03 LHSI TRAIN A LHIAB LHSI 6.35E-05 LHSI TRAINS A AND B LHIABC LHSI 9.79E-06 LHSI TRAINS A, B, AND C LHIAC LHSI 6.42E-05 LHSI TRAINS A AND C LHIB LHSI 4.50E-03 LHSI TRAIN B LHIBC LHSI 6.50E-05 LHSI TRAINS B AND C LHIC LHSI 4.45E-03 LHSI TRAIN C LIA LI 5.17E-09 LETDOWN ISOLATION (LI)- ALL SUPPORT Page 207 of 256
South Texas Project Risk-Informed GSI-191 Evaluation Volume 2: Probabilistic Risk Analysis RI-GSI 191 -V02 Revision I Table B.3-1 Master Frequency File Used for Point Estimate Event Tree Quantification (Continued)
SF Name Top Event SF Value Split Fraction Description ISF LIB LI 1.73E-07 LI - FAILURE OF TRAIN A POWER LIC LI 3.07E-04 LI - FAILURE OF TRAIN A AND C POWER LID LI 7.29E-06 LI - FAILURE OF PD PUMP LIE LI 7.58E-06 LI - FAILURE OF PD PUMP AND TRAIN A POWER LIF LI 5.56E-04 LI - FAILURE OF PD PUMP AND TRAIN B POWER LIG LI 5.52E-04 LI - FAILURE OF PD PUMP AND TRAIN C POWER LIH LI 8.55E-04 LI - FAILURE OF PD PUMP, TRAIN A AND C POWER LII LI 5.55E-04 LI - FAILURE OF TRAIN C SIGNAL LIJ LI 1.11E-03 LI - FAILURE OF TRAIN C SIGNAL AND PD PUMP LIK LI 1.69E-07 LI - FAILURE OF TRAIN C POWER LIL LI 5.55E-04 LI - FAILURE OF PD PUMP, TRAIN A AND B POWER LIY LI 0.00E+00 GS LIZ LI 1.OOE+00 GF LOA LO 1.93E-05 ALL SUPPORT LOAT LI 9.97E-14 LI AND LETDOWN CONTAINMENT ISOLATION FAILURE (LCI)
LOB LO 1.83E-05 LO - NO TRAIN A SUPPORT LOBT LI 3.16E-12 LI AND LCI FAILURE - NO TRAIN A POWER LOC LO 5.96E-04 LO - NO TRAIN B SUPPORT LOCT LI 3.08E-12 LI AND LCI FAILURE - NO TRAIN B POWER LOD LO 6.08E-04 LO - NO TRAIN C SUPPORT LODT LI 1.03E-10 LI AND LCI FAILURE - NO TRAIN C POWER LOE LO 5.54E-04 LO - NO TRAIN A & C SUPPORT LOEX LI 1.70E-07 LI AND LCI FAILURE - NO TRAIN A & C POWER LOF LO 6.04E-04 LO - NO TRAIN A & B SUPPORT LOFX LI 1.04E-10 LI AND LCI FAILURE - NO TRAIN A & B POWER Page 208 of 256
South Texas Project Risk-Informed GSI-191 Evaluation Volume 2: Probabilistic Risk Analysis RI-GSI191-V02 Revision 1 Table B.3-1 Master Frequency File Used for Point Estimate Event Tree Quantification (Continued)
SF Name Top Event SF Value Split Fraction Description ISF LOG LO 6.11 E-04 LO - NO TRAIN C SIGNAL LOGX LI 3.39E-07 LI AND LCI FAILURE - NO TRAIN C SIGNAL LOH LO 5.50E-04 LO - NO TRAIN A POWER OR TRAIN C SIGNAL LOHX LOHX LI 5.50E-04 LI AND LCI FAILURE - NO TRAIN A POWER OR TRAIN C SIGNAL LOY LO 0.OOE+00 NOT REQUIRED LOZ LO 1.OOE+00 GF LSA LS O.00E+00
- NO PORV FAILURE PRIOR TO VB LSB LS 8.00E-01 INDUCED PORV FAILURE WEN RCS PRESS >
2000 PSIA OR OP OPENS PORV LSC LS 1.OOE+00
- PORV STUCK OPEN AT UTAF MFFA MFS 5.OOE-02 MFW SYSTEM - POST TRIP MFFY MFS 0.OOE+00 GS MFFZ MFS 1.00E+00 GF N1Y N1 0.OOE+00 GS N1Z N1 1.OOE+00 SEQUENCES INVOLVING SUMP RECIRC N2Y N2 0.OOE+00 GS N2Z N2 1.OOE+00 EARLY CORE DAMAGE CORE SEQUENCES N3Y N3 0.OOE+00 GS N3Z N3 1.OOE+00 ISOLATION OF SECONDARY SIDE FAILED N4Y N4 0.00E+00 SGTR SEQUENCES NOT RECOVERED N4Z N4 1.OOE+00 RECOVERABLE SGTR SEQUENCES OBA OB 1.79E-02 OPERATOR OPENS PORVS FOR BLEED AND FEED (GT)
OBA1 OB 6.71 E-02 BLEED AND FEED (GT), OR=F DEPENDENCY OBA1A OB 8.53E-02 OBA1 - TRAIN B=F OBA1 B OB 8.53E-02 OBA1 -TRAIN A=F OBAlC OB 6.81 E-02 OBA1 - PORV A BLOCKED Page 209 of 256
South Texas Project Risk-Informed GSI-191 Evaluation Volume 2: Probabilistic Risk Analysis RI-GSI 191 -V02 Revision 1 Table B.3-1 Master Frequency File Used for Point Estimate Event Tree Quantification (Continued)
SF Name Top Event SF Value Split Fraction Description ISF OBAI D OB 6.74E-02 OBA1 - PORV B BLOCKED OBAI E OB 6.80E-02 OBA1 - PORVS A AND B BLOCKED OBAA OB 3.56E-02 OBA - TRAIN B=F OBAB OB 3.65E-02 OBA - TRAIN A=F OBAC OB 1.84E-02 OBA - PORV A BLOCKED OBAD OB 1.82E-02 OBA - PORV B BLOCKED OBAE OB 1.91E-02 OBA - PORV'S A AND B BLOCKED OBD OB 9.10E-03 OPERATOR OPENS PORVS FOR B&F (SGTR NO AF)
OBDA OB 2.69E-02 OBD - TRAIN B=F OBDB OB 2.73E-02 OBD - TRAIN A=F OBDC OB 9.64E-03 OBD - PORV A BLOCKED OBDD OB 9.73E-03 OBD - PORV B BLOCKED OBDE OB 1.03E-02 OBD - PORV'S A AND B BLOCKED OBF OB 1.36E-02 OPERATOR OPENS PORVS FOR B&F (SLOCA)
OBF1 OB 6.37E-02 BLEED AND FEED (SLOCA), OR=F DEPENDENCY OBFIA OB 8.08E-02 OBF1 - TRAIN B=F OBF1B OB 8.05E-02 OBF1 -TRAIN A=F OBFlC OB 6.41 E-02 OBF - PORV A BLOCKED OBF1D OB 6.40E-02 OBF - PORV B BLOCKED OBFI E OB 6.45E-02 OBF - PORVS A AND B BLOCKED OBFA OB 3.07E-02 OBF - TRAIN B=F OBFB OB 3.17E-02 OBF - TRAIN A=F OBFC OB 1.42E-02 OBF - PORV A BLOCKED OBFD OB 1.42E-02 OBF - PORV B BLOCKED OBFE OB 1.45E-02 OBF - PORV'S A AND B BLOCKED OBG OB 1.57E-02 OPERATOR OPENS PORVS FOR B&F (SLOCA&TT)
Page 210 of 256
South Texas Project Risk-Informed GSI-191 Evaluation Volume 2: Probabilistic Risk Analysis RI-GSI191-V02 Revision 1 Table B.3-1 Master Frequency File Used for Point Estimate Event Tree Quantification (Continued)
SF Name Top Event SF Value Split Fraction Description ISF OBGA OB 3.32E-02 OBG - TRAIN B=F OBGB OB 3.34E-02 OBG - TRAIN A=F OBGC OB 1.61 E-02 OBG - PORV A BLOCKED OBGD OB 1.61E-02 OBG - PORV B BLOCKED OBGE OB 1.65E-02 OBG - PORV'S A AND B BLOCKED OBH OB 1.82E-02 OPERATOR OPENS PORVS FOR B&F (SEISMIC EVENT)
OBHA OB 3.58E-02 OBH - TRAIN B=F OBHB OB 3.60E-02 OBH - TRAIN A=F OBHC OB 1.88E-02 OBH - PORV A BLOCKED OBHD OB 1.83E-02 OBH - PORV B BLOCKED OBHE OB 1.92E-02 OBH - PORV'S A AND B BLOCKED OBY OB O.OOE+00 GS OBZ OB 1.OOE+00 GF OCA OC 1.17E-04 OPERATORS START AT LEAST 1 OF 3 AVAILABLE TRAINS OCB OC 2.82E-04 OPERATORS START AT LEAST ONE RHR TRAIN (A AND B AVAILABLE)
OCC OC 2.90E-04 OPERATORS START AT LEAST ONE RHR TRAIN (A AND C AVAILABLE)
OCD OC 2.81 E-04 OPERATORS START AT LEAST ONE RHR TRAIN (B AND C AVAILABLE)
OCE OC 8.76E-03 OPERATORS START ONE TRAIN (A AVAILABLE)
OCF OC 8.72E-03 OPERATORS START ONE TRAIN (B AVAILABLE)
OCG OC 8.77E-03 OPERATORS START ONE TRAIN (C AVAILABLE)
OCL OC 2.74E-05 AT LEAST 1 OF 3 AVAILABLE RHR TRAINS START (RECOVERY ACTION; NO OPERATOR ERROR)
Page 211 of 256
South Texas Project Risk-Informed GSI-191 Evaluation Volume 2: Probabilistic Risk Analysis RI-GSI 191 -V02 Revision 1 Table B.3-1 Master Frequency File Used for Point Estimate Event Tree Quantification (Continued)
SF Name Top Event SF Value Split Fraction Description ISF 0CM OC 1.90E-04 AT LEAST 1 OF 2 AVAILABLE RHR TRAINS START (RECOVERY ACTION; NO OPERATOR ERROR)
OCN OC 8.65E-03 1 AVAILABLE RHR TRAIN STARTS (RECOVERY ACTION; NO OPERATOR ERROR)
OCY OC O.OOE+00 GS OCZ OC 1.OOE+00 GF ODA OD 1.08E-04 RCS COOLDOWN AND DEPRESS - SGTR ODC OD 5.76E-03 RAPID RCS COOLDOWN, HHSI=F ODE OD 1.29E-02 RCS COOLDOWN W/LOCAL OPERATION OF SG PORV ODSBO1 ODSBO 1.69E-02 Operator Depressurizes in SBO Conditions ODSBOY ODSBO O.OOE+00 Guarantee Success ODSBOZ ODSBO 1.OOE+00 Guarantee Failure ODY OD O.OOE+00 GS ODZ OD 1.OOE+00 GF OFA OF 4.32E-03 GT - SI NOT REQUIRED, AFW=F OFFSl OFFS 1.OOE-03 Operators secure all operating spray pumps during recirculation OFFSY OFFS O.OOE+00 Operators secure all operating spray pumps during recirculation OFFSZ OFFS 1.OOE+00 Operators secure all operating spray pumps during recirculation OFY OF O.OOE+00 GS OFZ OF 1.Q0E+00 GF OGA OG 5.39E-03 LOOP AFTER EVENT OGRA OGR 3.34E-01 NON-RECOVERY OF PLANT CENTERED LOOP OGRB OGR 4.OOE-01 NON-RECOVERY OF SWITCHYARD CENTERED S6.57-01NONRECVERYOFRIDRELTELOOP OGRC OGR 6.57E-01 NON-RECOVERY OF GRID RELATED LOOP Page 212 of 256
South Texas Project Risk-Informed GSI-191 Evaluation Volume 2: Probabilistic Risk Analysis RI-GSI 19 1-V02 Revision 1 Table B.3-1 Master Frequency File Used for Point Estimate Event Tree Quantification (Continued)
SF Name Top Event SF Value Split Fraction Description ISF OGRD OGR 6.80E-01 NON-RECOVERY OF WEATHER RELATED LOOP OGRY OGR O.OOE+00 GS OGRZ OGR 1.OOE+00 GF OGY OG 0.00E+00 GS OGZ OG 1.OOE+00 GF OLA OL 5.67E-03 OPER DEPRESS BY BLOWING DOWN SGS OLY OL O.OOE+00 NOT REQUIRED OLZ OL 1.OOE+00 GF OMA OM 8.71 E-01 DG RECOVERY - ONE DG FAILED OMB OM 8.72E-01 DG RECOVERY - TWO DGS FAILED OMC OM 8.69E-01 DG RECOVERY - THREE DGS FAILED OMY OM O.OOE+00 NOT REQUIRED OMZ OM 1.OOE+00 GF ORA OR 3.97E-04 OPER STARTS TRAIN (GT)
ORE OR 9.42E-04 OPER STARTS TRAIN (LOOP)
ORG OR 8.1OE-02 OPER STARTS TRAIN (LOCA)
ORM OR 2.08E-03 OPER STARTS TRAIN (CNTRL RM FIRE)
ORO OR 1.37E-01 OPER STARTS TRAIN (SEISMIC)
ORY OR O.OOE+00 GS ORZ OR 1.OOE+00 GF OS11 OSi 5.OOE-03 Operators initially secure one spray pump if all three trains operating OSlY OSi O.OE+00 Operators initially secure one spray pump if all three trains operating OSIZ OSi 1.OOE+00 Operators initially secure one spray pump if all three trains operating OSA OS 6.11E-03 OPERATOR FAILS TO OPEN EAB DOORS AND START SMOKE PURGE OSY OS O.OOE+00 GS Page 213 of 256
South Texas Project Risk-Informed GSI-191 Evaluation Volume 2: Probabilistic Risk Analysis RI-GSI 19 1-V02 Revision 1 Table B.3-1 Master Frequency File Used for Point Estimate Event Tree Quantification (Continued)
SF Name Top Event SF Value Split Fraction Description ISF OSZ OS 1.OOE+00 GF OTA OT 1.43E-02 OPER MANUALLY TRIPS REACTOR - NO MFW, ATWS OTY OT O.OOE+00 GS OTZ OT 1.OOE+00 GF OXB OX 3.07E-03 OPERATOR ALIGNS EMERG XFMR - OG=F OXB1 OX 5.33E-02 OPER ALIGNS EMERG XFMR-OG=F, CONDITIONAL (LD)
OXY OX O.OOE+00 GS OXZ Ox 1.00E+00 GF PAA PA 1.38E-03 SI COMMON TRAIN A FAILS SICA PAXA PA 1.53E-03 SI COMMON TRAIN A FAILS SIXA PAY PA O.OOE+00 GS PAZ PA 1.OOE+00 GF PBA PB 1.35E-03 SI COMMON TRAIN B - PA=S SICB PBB PB 4.73E-03 SI COMMON TRAIN B - PA=F SICAB PBC PB 1.35E-03 SI COMMON TRAIN B - PA=B SICB PBXA PB 1.53E-03 SI COMMON TRAIN B - PA=S SIXB PBXB PB 4.62E-03 SI COMMON TRAIN B - PA=F SIXAB PBXC PB 1.53E-03 SI COMMON TRAIN B - PA=B SIXB PBY PB O.OOE+00 GS PBZ PB 1.OOE+00 GF PDA PD 1.21 E-02 OFF SITE POWER AVAILABLE PDB PD 2.63E-01 LOSS OF 4.16kV ESF/EAB HVAC PDC PD 3.12E-02 OFF SITE POWER AVAILABLE (HE0003)
PDD PD 1.03E-01 OFF SITE POWER AVAILABLE (HE0004) SEISMIC PDE PD 1.76E-02 OFF SITE POWER AVAILABLE (HE0005) SEISMIC PDF PD 2.57E-01 LOOP/SBO Page 214 of 256
South Texas Project Risk-Informed GSI-191 Evaluation Volume 2: Probabilistic Risk Analysis RI-GSI191-V02 Revision I Table B.3-1 Master Frequency File Used for Point Estimate Event Tree Quantification (Continued)
SF Name Top Event SF Value Split Fraction Description ISF PDY PD O.OOE+00 GS PDZ PD 1.OOE+00 GF POSA PO 7.73E-05 SGTR, ALL SUPPORT POSAC PO 7.98E-05 POSA - PORV A Blocked POSAD PO 7.89E-05 POSA - PORV B Blocked POSAE PO 9.62E-05 POSA - Both PORVs Blocked POSB PO 4.56E-03 SGTR, LOSS OF DC TRAIN A POSBC PO 4.43E-03 POSB - PORV A Blocked POSBD PO 5.OOE-03 POSB - PORV B Blocked POSBE PO 4.97E-03 POSB - Both PORVs Blocked POSC PO 4.42E-03 SGTR, LOSS OF DC TRAIN B POSCC PO 4.91 E-03 POSC - PORV A Blocked POSCD PO 4.40E-03 POSC - PORV B Blocked POSCE PO 4.97E-03 POSC - Both PORVs Blocked POSD PO 2.19E-02 SGTR, LOSS OF DC TRAIN A AND AC TRAIN B POSDC PO 2.25E-02 POSD - PORV A Blocked POSDD PO 1.OOE+00 POSD - PORV B Blocked POSDE PO 1.OOE+00 POSD - Both PORVs Blocked POSE PO 2.20E-02 SGTR, LOSS OF DC TRAIN B AND AC TRAIN A POSEC PO 1.OOE+00 POSE - PORV A Blocked POSED PO 2.24E-02 POSE - PORV B Blocked POSEE PO 1.OOE+00 POSE - Both PORVs Blocked POSF PO 3.69E-03 SGTR, LOSS OF AC TRAIN A AND AC TRAIN B POSFC PO 2.17E-02 POSF - PORV A Blocked POSFD PO 2.29E-02 POSF - PORV B Blocked POSFE PO 1.OOE+00 POSF - Both PORVs Blocked POSG PO 1.57E-04 SGTR, LOSS OF AC TRAIN A Page 215 of 256
South Texas Project Risk-Informed GSI-191 Evaluation Volume 2: Probabilistic Risk Analysis RI-GSI 191 -V02 Revision 1 Table B.3-1 Master Frequency File Used for Point Estimate Event Tree Quantification (Continued)
SF Name Top Event SF Value Split Fraction Description ISF POSGC PO 4.40E-03 POSG - PORV A Blocked POSGD PO 1.77E-04 POSG - PORV B Blocked POSGE PO 4.97E-03 POSG - Both PORVs Blocked POSH PO 1.56E-04 SGTR, LOSS OF AC TRAIN B POSHC PO 4.44E-03 POSH - PORV A Blocked POSHD PO 1.68E-04 POSH - PORV B Blocked POSHE PO 4.90E-03 POSH - Both PORVs Blocked POY PO O.OOE+00 GS POZ PO 1.OOE+00 GF PPV1A PPV1 3.97E-02 1/2 PORVS FAIL - ALL SUPPORT - ATWS PPV1AC PPV1 1.OOE+00 PPV1A - PORV A Blocked PPV1AD PPV1 1.OOE+00 PPV1A - PORV B Blocked PPV1AE PPV1 1.OOE+00 PPV1A - Both PORVs Blocked PPV1Y PPV1 O.OOE+00 GS PPVIZ PPV1 1.OOE+00 GF PPV2A PPV2 3.78E-03 2/2 PORVS FAIL - ALL SUPPORT - ATWS PPV2AC PPV2 2.26E-02 PPV2A - PORV A Blocked PPV2AD PPV2 2.26E-02 PPV2A - PORV B Blocked PPV2AE PPV2 1.OOE+00 PPV2A - Both PORVs Blocked PPV2B PPV2 2.32E-02 2/2 PORVS FAIL - LOSS OF DC TRAIN A - ATWS PPV2BC PPV2 2.27E-02 PPV2B - PORV A Blocked PPV2BD PPV2 1.OOE+00 PPV2B - PORV B Blocked PPV2BE PPV2 1.OOE+00 PPV2B - Both PORVs Blocked PPV2C PPV2 2.22E-02 2/2 PORVS FAIL - LOSS OF DC TRAIN B - ATWS PPV2CC PPV2 1.OOE+00 PPV2C - PORV A Blocked PPV2CD PPV2 2.25E-02 PPV2C - PORV B Blocked PPV2CE PPV2 1.OOE+00 PPV2C - Both PORVs Blocked Page 216 of 256
South Texas Project Risk-Informed GSI-191 Evaluation Volume 2: Probabilistic Risk Analysis RI-GSI191-V02 Revision 1 Table B.3-1 Master Frequency File Used for Point Estimate Event Tree Quantification (Continued)
SF Name Top Event SF Value Split Fraction Description ISF PPV2Y PPV2 O.OOE+00 GS PPV2Z PPV2 1.OOE+00 GF PRA PR 8.54E-03 2 OF 2 PORVS RESEAT AFTER OPENING PRB PR 4.31E-03 1 OF 1 PORV RESEATS AFTER OPENING PRC PR 2.41E-01 2 OF 2 PORVS AND 3 SRVS RESEAT AFTER WATER RELIEF PRD PR 1.34E-02 2 OF 2 PORVS AND 3 SRVS RESEAT AFTER STEAM RELIEF PRE PR 2.43E-01 1 OF 1 PORVS RESEAT AND 3 SRVS RESEAT AFTER WATER RELIEF PRF PR 2.43E-01 3 OF 3 SRVS RESEAT AFTER ATWS - WATER RELIEF PRG PR 4.83E-03 1 OF 1 PORVS AND 3 SRVS RESEAT AFTER STEAM RELIEF PRH PR 4.74E-03 3 OF 3 SRVS RESEAT AFTER STEAM RELIEF PRI PR 5.74E-05 OPER FAILS TO CLOSE BLOCK VALVE A -
POWER AVAIL AT ElA, E1B PRJ PR 4.42E-03 OPER FAILS TO CLOSE BLOCK VALVE A -
POWER AVAIL AT ElA PRY PR O.OOE+00 GS PRZ PR 1.OOE+00 GF PSCA PSC O.OOE+00 SEAL COOLING / INJECTION AVAILABLE PSCB PSC 2.82E-01 NO SEAL COOLING / INJECTION PSV1A PSV1 1.03E-02 1 OF 3 PSVs FAIL TO OPEN - ATWS PSV1Y PSV1 O.OOE+00 GS PSV1Z PSV1 1.OOE+00 GF PSV2A PSV2 1.82E-04 2 OF 3 PSVs FAIL TO OPEN - ATWS PSV2Y PSV2 O.OOE+00 GS PSV2Z PSV2 1.OOE+00 GF PV1A PORV 6.51E-03 PORV A AVAILABLE Page 217 of 256
South Texas Project Risk-Informed GSI-191 Evaluation Volume 2: Probabilistic Risk Analysis RI-GSI 191 -V02 Revision 1 Table B.3-1 Master Frequency File Used for Point Estimate Event Tree Quantification (Continued)
SF Name Top Event SF Value Split Fraction Description ISF PV1B PORV 6.45E-03 PORV B AVAILABLE PV1C PORV 6.49E-03 PORV C AVAILABLE PV1 D PORV 6.46E-03 PORV D AVAILABLE PV2AB PORV 1.22E-04 PORVS A&B AVAILABLE PV2AC PORV 1.21 E-04 PORVS A&C AVAILABLE PV2AD PORV 1.23E-04 PORVS A&D AVAILABLE PV2BC PORV 1.23E-04 PORVS B&C AVAILABLE PV2BD PORV 1.19E-04 PORVS B&D AVAILABLE PV2CD PORV 1.24E-04 PORVS C&D AVAILABLE PV3ABC PORV 1.38E-05 PORVS A,B,&C AVAILABLE PV3ABD PORV 1.44E-05 PORVS A,B,&D AVAILABLE PV3ACD PORV 1.40E-05 PORVS A,C,&D AVAILABLE PV3BCD PORV 1.45E-05 PORVS B,C,&D AVAILABLE PV4 PORV 5.30E-06 ALL PORVS AVAILABLE PV4D PORV 2.54E-02 PORV'S - RAPID DEPRESSURIZATION PV4DX PORV 2.58E-02 PORVS-RAPID DEPRESS SBO PVY PORV O.OOE+00 GS PVZ PORV 1.OOE+00 GF PZA PZ 1.37E-03 SI COMMON TRAIN C - PA=S, PB=S SICC PZB PZ 3.26E-03 SI COMMON TRAIN C - PA=S, PB=F SICBC PZC PZ 3.21 E-03 SI COMMON TRAIN C - PA=F, PB=S SICAC PZD PZ 3.30E-01 SI COMMON TRAIN C - PA=F, PB=F SICABC PZE PZ 1.38E-03 SI COMMON TRAIN C - PA=B, PB=S SICC PZF PZ 4.83E-03 SI COMMON TRAIN C - PA=B, PB=F SICBC PZG PZ 1.38E-03 SI COMMON TRAIN C - PA=S, PB=B SICC PZH PZ 4.76E-03 SI COMMON TRAIN C - PA=F, PB=B SICAC PZI PZ 1.38E-03 SI COMMON TRAIN C - PA=B, PB=B SICC Page 218 of 256
South Texas Project Risk-Informed GSI-191 Evaluation Volume 2: Probabilistic Risk Analysis RI-GSI191-V02 Revision 1 Table B.3-1 Master Frequency File Used for Point Estimate Event Tree Quantification (Continued)
SF Name Top Event SF Value Split Fraction Description ISF PZXA PZ 1.52E-03 SI COMMON TRAIN C - PA=S, PB=S SIXC PZXB PZ 3.19E-03 SI COMMON TRAIN C - PA=S, PB=F SIXBC PZXC PZ 3.21 E-03 SI COMMON TRAIN C - PA=F, PB=S SIXAC PZXD PZ 3.OOE-01 SI COMMON TRAIN C - PA=F, PB=F SIXABC PZXE PZ 1.53E-03 SI COMMON TRAIN C - PA=B, PB=S SIXC PZXF PZ 4.56E-03 SI COMMON TRAIN C - PA=B, PB=F SIXBC PZXG PZ 1.53E-03 SI COMMON TRAIN C - PA=S, PB=B SIXC PZXH PZ 4.58E-03 SI COMMON TRAIN C - PA=F, PB=B SIXAC PZXI PZ 1.53E-03 SI COMMON TRAIN C - PA=B, PB=B SIXC PZY PZ O.OOE+00 GS PZZ PZ 1.OOE+00 GF QAA QA 2.1OE-03 QDPS A -ALL SUPPORT QDPO QAY QA O.OOE+00 GS QAZ QA 1.OOE+00 GF QBA QB 2.01E-03 QDPS B -ALL SUPPORT QDPN QBB QB 1.11E-03 QA=F QDPK QBC QB 2.01E-03 SINGLE TRAIN QDPN QBY QB O.OOE+00 GS QBZ QB 1.OOE+00 GF QCA QC 2.07E-03 QDPS C - ALL SUPPORT QDPM QCB QC 1.15E-03 QB=F QDPH QCC QC 1.08E-03 QA=F QDPJ QCD QC 1.14E-02 QA=F, QB=F QDPE QCE QC 2.06E-03 QA BYPASS QDPM QCF QC 1.16E-03 QB=F, QA=B QDPH QCG QC 2.07E-03 QB BYPASS QDPM QCH QC 1.1OE-03 QA=F, QB=B QDPJ Page 219 of 256
South Texas Project Risk-Informed GSI-191 Evaluation Volume 2: Probabilistic Risk Analysis RI-GSI 191 -V02 Revision 1 Table B.3-1 Master Frequency File Used for Point Estimate Event Tree Quantification (Continued)
SF Name Top Event SF Value Split Fraction Description ISF QCI QC 2.06E-03 SINGLE TRAIN QDPM QCY QC O.OOE+00 GS QCZ QC 1.OOE+00 GF QDA QD 2.05E-03 QDPS D - ALL SUPPORT QDPL QDAA QD 2.04E-03 QB=B, QC=B QDPL QDAB QD 1.12E-03 QB=B, QC=B, QA=F QDPI QDAC QD 2.04E-03 SINGLE TRAIN QDPL QDB QD 1.14E-03 QC=F QDPF QDC QD 1.15E-03 QB=F QDPG QDD QD 1.11E-03 QA=F QDPI QDE QD 7.60E-03 QB=F, QC=F QDPB QDF QD 7.38E-03 QA=F, QC=F QDPC QDG QD 7.26E-03 QA=F, QB=F QDPD QDH QD 3.30E-01 QA, QB, QC=F QDPA QDI QD 2.05E-03 QA=B QDPL QDJ QD 1.14E-03 QA=B, QC=F QDPF QDK QD 1.16E-03 QA=B, QB=F QDPG QDL QD 1.13E-02 QA=B, QB=F, QC=F QDPB QDM QD 2.05E-03 QB=B QDPL QDN QD 1.14E-03 QB=B, QC=F QDPF QDO QD 1.11E-03 QB=B, QA=F QDPI QDP QD 1.11E-02 QB=B, QA=F, QC=F QDPC QDPA QDPS 8.76E-09 QDPS - ALL SUPPORT QDPB QDPS 2.63E-08 LOSS OF TRAIN A QDPC QDPS 2.55E-08 LOSS OF TRAIN B QDPD QDPS 2.55E-08 LOSS OF TRAIN C QDPE QDPS 2.66E-08 LOSS OF TRAIN D Page 220 of 256
South Texas Project Risk-Informed GSI-191 Evaluation Volume 2: Probabilistic Risk Analysis RI-GSI191-V02 Revision I Table B.3-1 Master Frequency File Used for Point Estimate Event Tree Quantification (Continued)
SF Name Top Event SF Value Split Fraction Description ISF QDPF QDPS 2.38E-06 LOSS OF TRAINS A, B QDPG QDPS 2.35E-06 LOSS OF TRAINS A, C QDPH QDPS 2.34E-06 LOSS OF TRAINS A, D QDPI QDPS 2.36E-06 LOSS OF TRAINS B, C QDPJ QDPS 2.30E-06 LOSS OF TRAINS B, D QDPK QDPS 2.34E-06 LOSS OF TRAINS C, D QDPL QDPS 2.04E-03 LOSS OF TRAINS A, B, C QDPM QDPS 2.06E-03 LOSS OF TRAINS A, B, D QDPN QDPS 2.01E-03 LOSS OF TRAINS A, C, D QDPO QDPS 2.1OE-03 LOSS OF TRAINS B, C, D QDQ QD 2.05E-03 QC=B QDPL QDR QD 1.16E-03 QC=B, QB=F QDPG QDS QD 1.11E-03 QC=B, QA=F QDPI QDT QD 1.09E-02 QC=B, QA=F, QB=F QDPD QDU QD 2.04E-03 QA=B, QB=B QDPL QDV QD 1.16E-03 QA=B, QB=B, QC=F QDPF QDW QD 2.04E-03 QA=B, QC=B QDPL QDX QD 1.17E-03 QA=B, QC=B, QB=F QDPG QDY QD O.OOE+00 GS QDZ QD 1.OOE+00 GF QUANT TYPE O.OOE+00 TYPE OF QUANTIFICATION, 0 FOR AVG CDF OR 1 FOR SPECIFIC MAINTENANCE RAA RA 1.25E-03 RECIRC TRAIN A FAILS - ALL SUPPORT SIRA RAR RA 2.13E-04 RECIRC TRAIN A FAILS WITH OPERATOR RECOVERY ACTION RAY RA 0.OOE+00 GS RAZ RA 1.OOE+00 GF RBA RB 1.22E-03 RECIRC TRAIN B - RA=SIN A SUCCESS SIRB Page 221 of 256
South Texas Project Risk-Informed GSI-191 Evaluation Volume 2: Probabilistic Risk Analysis RI-GSI 19 1-V02 Revision 1 Table B.3-1 Master Frequency File Used for Point Estimate Event Tree Quantification (Continued)
SF Name Top Event SF Value Split Fraction Description ISF RBB RB 2.53E-02 RECIRC TRAIN B - RA=F SIRAB RBC RB 1.25E-03 RECIRC TRAIN B - RA=B SIRB RBR RB 2.12E-04 Recirculation Train B Recovery RBY RB O.OOE+00 GS RBZ RB 1.OOE+00 GF RCA RC 1.18E-03 RECIRC TRAIN C - RA=S, RB=S SIRC RCB RC 9.89E-03 RECIRC TRAIN C - RA=S, RB=F SIRBC RCC RC 1.03E-02 RECIRC TRAIN C - RA=F, RB=S SIRAC RCD RC 6.12E-01 RECIRC TRAIN C - RA=F, RB=F SIRABC RCE RC 1.19E-03 RECIRC TRAIN C - RA=B, RB=S SIRC RCF RC 2.50E-02 RECIRC TRAIN C - RA=B, RB=F SIRBC RCG RC 1.19E-03 RECIRC TRAIN C - RA=S, RB=B SIRC RCH RC 2.55E-02 RECIRC TRAIN C - RA=F, RB=B SIRAC RCJ RC 1.22E-03 RECIRC TRAIN C - RA=B, RB=B SIRC RCR RC 2.19E-04 Operator Recovery Recirculation Train C RCY RC O.OOE+00 GS RCZ RC 1.OOE+00 GF RE1 RE 5.73E-04 FAIL TO ISOLATE STUCK OPEN PORV RE4A RE 1.71 E-01 Recovery Emergency Sump Recirc MOV Train A RE4B RE 1.69E-01 Recovery Emergency Sump Recirc MOV Train B RE4C RE 1.80E-01 Recovery Emergency Sump Recirc MOV Train C RE5 REAF 6.85E-01 OPERATOR FAILS TO RECOVER TDAFW PUMP REA RE 5.73E-04 SGTR SEQ RECOVERY FOR ALL SUPPORT AVAIL REAFY REAF O.OOE+00 AFW SUCCESSFUL REAFZ REAF 1.OOE+00 AFW GUARANTEED FAILED REB RE 1.12E-01 TDAFWP RECOVERY (SEISMIC)
Page 222 of 256
South Texas Project Risk-Informed GSI-191 Evaluation Volume 2: Probabilistic Risk Analysis RI-GSI191-V02 Revision 1 Table B.3-1 Master Frequency File Used for Point Estimate Event Tree Quantification (Continued)
SF Name Top Event SF Value Split Fraction Description ISF REC RE 8.81 E-03 SGTR SEQ RECOVERY WITH 1 TRAIN AVAILABLE REG10 RE 1.12E-01 2DG Failure with no planned maintenance, Primary G2AB System Valve Not Closed, AFW Successful, Operator Depressurize Success REG11 RE 2.39E-01 2DG Failure with no planned maintenance, Primary G2AB System Valve Not Closed, AFW Successful, Operator Depressurize Failure REG12 RE 1.45E-01 1DG Failure with no planned maintenance, Primary GlA System Valve Not Closed, AFW Successful, Operator Depressurize Success REG13 RE 3.98E-01 1DG Failure with no planned maintenance, Primary GlA System Valve Not Closed, AFW Successful, Operator Depressurize Failure REG14 RE 2.34E-01 3DG Failure with no planned maintenance, Primary G3ABC System Valve Closed, AFW Failed, Operator Depressurize Success REG15 RE 2.34E-01 3DG Failure with no planned maintenance, Primary G3ABC System Valve Closed, AFW Failed, Operator Depressurize Failure REG16 RE 2.05E-01 2DG Failure with no planned maintenance, Primary G2AB System Valve Closed, AFW Failed, Operator Depressurize Success REG17 RE 2.05E-01 2DG Failure with no planned maintenance, Primary G2AB System Valve Closed, AFW Failed, Operator Depressurize Failure REG18 RE 3.29E-01 1DG Failure with no planned maintenance, Primary GlA System Valve Closed, AFW Failed, Operator Depressurize Success REG19 RE 3.29E-01 1DG Failure with no planned maintenance, Primary GlA System Valve Closed, AFW Failed, Operator Depressurize Failure Page 223 of 256
South Texas Project Risk-informed GSI-191 Evaluation Volume 2: Probabilistic Risk Analysis RI-GS1191 -V02 Revision 1 Table B.3-1 Master Frequency File Used for Point Estimate Event Tree Quantification (Continued)
SF Name Top Event SF Value Split Fraction Description ISF REG2 RE 6.82E-02 3DG Failure with no planned maintenance, PDP G3ABC Failed, Primary System Valve Closed, AFW Successful, Operator Depressurize Success REG20 RE 6.76E-02 3DG Failure with no planned maintenance, PDP G3ABC Successful, Primary System Valve Closed, AFW Successful, Operator Depressurize Success REG21 RE 6.76E-02 3DG Failure with no planned maintenance, PDP G3ABC Successful, Primary System Valve Closed, AFW Successful, Operator Depressurize Failure REG22 RE 6.79E-02 2DG Failure with no planned maintenance, PDP G2AB Successful, Primary System Valve Closed, AFW Successful, Operator Depressurize Success REG23 RE 6.79E-02 2DG Failure with no planned maintenance, PDP G2AB Successful, Primary System Valve Closed, AFW Successful, Operator Depressurize Failure REG24 RE 6.58E-02 1DG Failure with no planned maintenance, PDP GlA Successful, Primary System Valve Closed, AFW Successful, Operator Depressurize Success REG25 RE 6.58E-02 1DG Failure with no planned maintenance, PDP GlA Successful, Primary System Valve Closed, AFW Successful, Operator Depressurize Failure REG26 RE 2.77E-01 3DG Failure with no planned maintenance, Primary G3ABC System Valve not Closed, AFW Failure, Operator Depressurize Success REG27 RE 2.77E-01 3DG Failure with no planned maintenance, Primary G3ABC System Valve not Closed, AFW Failure, Operator Depressurize Failure REG28 RE 2.39E-01 2DG Failure with no planned maintenance, Primary G2AB System Valve not Closed, AFW Failure, Operator Depressurize Success REG29 RE 2.39E-01 2DG Failure with no planned maintenance, Primary G2AB System Valve not Closed, AFW Failure, Operator Depressurize Failure Page 224 of 256
South Texas Project Risk-Informed GSI-191 Evaluation Volume 2: Probabilistic Risk Analysis RI-GSI 19 1-V02 Revision 1 Table B.3-1 Master Frequency File Used for Point Estimate Event Tree Quantification (Continued)
SF Name Top Event SF Value Split Fraction Description ISF REG3 RE 7.20E-02 3DG Failure with no planned maintenance, PDP G3ABC Failed, Primary System Valve Closed, AFW Successful, Operator Depressurize Failure REG30 RE 3.98E-01 1DG Failure with no planned maintenance, Primary GlA System Valve not Closed, AFW Failure, Operator Depressurize Success REG31 RE 3.98E-01 1DG Failure with no planned maintenance, Primary GlA System Valve not Closed, AFW Failure, Operator Depressurize Failure REG4 RE 6.84E-02 2DG Failure with no planned maintenance, PDP G2AB Failed, Primary System Valve Closed, AFW Successful, Operator Depressurize Success REG5 RE 7.16E-02 2DG Failure with no planned maintenance, PDP G2AB Failed, Primary System Valve Closed, AFW Successful, Operator Depressurize Failure REG6 RE 6.65E-02 1 DG Failure with no planned maintenance, PDP GlA Failed, Primary System Valve Closed, AFW Successful, Operator Depressurize Success REG7 RE 7.20E-02 1DG Failure with no planned maintenance, PDP GlA Failed, Primary System Valve Closed, AFW Successful, Operator Depressurize Failure REG8 RE 1.20E-01 3DG Failure with no planned maintenance, Primary G3ABC System Valve Not Closed, AFW Successful, Operator Depressurize Success REG9 RE 2.77E-01 3DG Failure with no planned maintenance, Primary G3ABC System Valve Not Closed, AFW Successful,
_Operator Depressurize Failure REP10 RE 1.80E-01 2DG Failure with no planned maintenance, Primary G2AB System Valve Not Closed, AFW Successful, Operator Depressurize Success REP1 1 RE 2.93E-01 2DG Failure with no planned maintenance, Primary G2AB System Valve Not Closed, AFW Successful, Operator Depressurize Failure Page 225 of 256
South Texas Project Risk-Informed GSI-191 Evaluation Volume 2: Probabilistic Risk Analysis RI-GSI191-V02 Revision 1 Table B.3-1 Master Frequency File Used for Point Estimate Event Tree Quantification (Continued)
SF Name Top Event SF Value Split Fraction Description ISF REP12 RE 2.08E-01 1DG Failure with no planned maintenance, Primary GlA System Valve Not Closed, AFW Successful, SOperator Depressurize Success REP13 RE 4.31E-01 1DG Failure with no planned maintenance, Primary GlA System Valve Not Closed, AFW Successful, Operator Depressurize Failure REP14 RE 2.86E-01 3DG Failure with no planned maintenance, Primary G3ABC System Valve Closed, AFW Failed, Operator Depressurize Success REP15 RE 2.86E-01 3DG Failure with no planned maintenance, Primary G3ABC System Valve Closed, AFW Failed, Operator Depressurize Failure REP16 RE 2.60E-01 2DG Failure with no planned maintenance, Primary G2AB System Valve Closed, AFW Failed, Operator Depressurize Success REP17 RE 2.60E-01 2DG Failure with no planned maintenance, Primary G2AB System Valve Closed, AFW Failed, Operator Depressurize Failure REP18 RE 3.65E-01 1DG Failure with no planned maintenance, Primary GlA System Valve Closed, AFW Failed, Operator Depressurize Success REP19 RE 3.65E-01 1DG Failure with no planned maintenance, Primary GlA System Valve Closed, AFW Failed, Operator Depressurize Failure REP2 RE 1.35E-01 3DG Failure with no planned maintenance, PDP G3ABC Failed, Primary System Valve Closed, AFW Successful, Operator Depressurize Success REP20 RE 1.35E-01 3DG Failure with no planned maintenance, PDP G3ABC Successful, Primary System Valve Closed, AFW Successful, Operator Depressurize Success REP21 RE 1.35E-01 3DG Failure with no planned maintenance, PDP G3ABC Successful, Primary System Valve Closed, AFW Successful, Operator Depressurize Failure Page 226 of 256
South Texas Project Risk-Informed GSI-191 Evaluation Volume 2: Probabilistic Risk Analysis RI-GSI191-V02 Revision 1 Table B.3-1 Master Frequency File Used for Point Estimate Event Tree Quantification (Continued)
SF Name Top Event SF Value Split Fraction Description ISF REP22 RE 1.35E-01 2DG Failure with no planned maintenance, PDP G2AB Successful, Primary System Valve Closed, AFW Successful, Operator Depressurize Success REP23 RE 1.35E-01 2DG Failure with no planned maintenance, PDP G2AB Successful, Primary System Valve Closed, AFW Successful, Operator Depressurize Failure REP24 RE 1.31E-01 1DG Failure with no planned maintenance, PDP GlA Successful, Primary System Valve Closed, AFW Successful, Operator Depressurize Success REP25 RE 1.31E-01 1DG Failure with no planned maintenance, PDP GlA Successful, Primary System Valve Closed, AFW Successful, Operator Depressurize Failure REP26 RE 3.26E-01 3DG Failure with no planned maintenance, Primary G3ABC System Valve not Closed, AFW Failure, Operator Depressurize Success REP27 RE 3.26E-01 3DG Failure with no planned maintenance, Primary G3ABC System Valve not Closed, AFW Failure, Operator Depressurize Failure REP28 RE 2.93E-01 2DG Failure with no planned maintenance, Primary G2AB System Valve not Closed, AFW Failure, Operator Depressurize Success REP29 RE 2.93E-01 2DG Failure with no planned maintenance, Primary G2AB System Valve not Closed, AFW Failure, Operator Depressurize Failure REP3 RE 1.40E-01 3DG Failure with no planned maintenance, PDP G3ABC Failed, Primary System Valve Closed, AFW Successful, Operator Depressurize Failure REP30 RE 4.31 E-01 1DG Failure with no planned maintenance, Primary GlA System Valve not Closed, AFW Failure, Operator IDepressurize Success REP31 RE 4.31 E-0 1 1DG Failure with no planned maintenance, Primary G1A System Valve not Closed, AFW Failure, Operator Depressurize Failure Page 227 of 256
South Texas Project Risk-Informed GSI-191 Evaluation Volume 2: Probabilistic Risk Analysis RI-GSI191-V02 Revision 1 Table B.3-1 Master Frequency File Used for Point Estimate Event Tree Quantification (Continued)
SF Name Top Event SF Value Split Fraction Description ISF REP4 RE 1.36E-01 2DG Failure with no planned maintenance, PDP G2AB Failed, Primary System Valve Closed, AFW Successful, Operator Depressurize Success REP5 RE 1.40E-01 2DG Failure with no planned maintenance, PDP G2AB Failed, Primary System Valve Closed, AFW Successful, Operator Depressurize Failure REP6 RE 1.32E-01 1DG Failure with no planned maintenance, PDP GlA Failed, Primary System Valve Closed, AFW Successful, Operator Depressurize Success REP7 RE 1.39E-01 1DG Failure with no planned maintenance, PDP GlA Failed, Primary System Valve Closed, AFW Successful, Operator Depressurize Failure REP8 RE 1.88E-01 3DG Failure with no planned maintenance, Primary G3ABC System Valve Not Closed, AFW Successful, Operator Depressurize Success REP9 RE 3.26E-01 3DG Failure with no planned maintenance, Primary G3ABC System Valve Not Closed, AFW Successful, Operator Depressurize Failure RES10 RE 1.65E-01 2DG Failure with no planned maintenance, Primary G2AB System Valve Not Closed, AFW Successful, Operator Depressurize Success RES11 RE 2.83E-01 2DG Failure with no planned maintenance, Primary G2AB System Valve Not Closed, AFW Successful, Operator Depressurize Failure RES12 RE 1.98E-01 1DG Failure with no planned maintenance, Primary GlA System Valve Not Closed, AFW Successful, Operator Depressurize Success RES13 RE 4.29E-01 1DG Failure with no planned maintenance, Primary GlA System Valve Not Closed, AFW Successful, Operator Depressurize Failure RES14 RE 2.78E-01 3DG Failure with no planned maintenance, Primary G3ABC System Valve Closed, AFW Failed, Operator Depressurize Success
_I Page 228 of 256
South Texas Project Risk-Informed GSI-191 Evaluation Volume 2: Probabilistic Risk Analysis RI-GSI191-V02 Revision I Table B.3-1 Master Frequency File Used for Point Estimate Event Tree Quantification (Continued)
SF Name Top Event SF Value Split Fraction Description ISF RES15 RE 2.78E-01 3DG Failure with no planned maintenance, Primary G3ABC System Valve Closed, AFW Failed, Operator Depressurize Failure RES16 RE 2.50E-01 2DG Failure with no planned maintenance, Primary G2AB System Valve Closed, AFW Failed, Operator Depressurize Success RES17 RE 2.50E-01 2DG Failure with no planned maintenance, Primary G2AB System Valve Closed, AFW Failed, Operator Depressurize Failure RES18 RE 3.63E-01 1DG Failure with no planned maintenance, Primary GlA System Valve Closed, AFW Failed, Operator Depressurize Success RES19 RE 3.63E-01 1DG Failure with no planned maintenance, Primary GlA System Valve Closed, AFW Failed, Operator Depressurize Failure RES2 RE 1.15E-01 3DG Failure with no planned maintenance, PDP G3ABC Failed, Primary System Valve Closed, AFW Successful, Operator Depressurize Success RES20 RE 1.14E-01 3DG Failure with no planned maintenance, PDP G3ABC Successful, Primary System Valve Closed, AFW Successful, Operator Depressurize Success RES21 RE 1.14E-01 3DG Failure with no planned maintenance, PDP G3ABC Successful, Primary System Valve Closed, AFW Successful, Operator Depressurize Failure RES22 RE 1.15E-01 2DG Failure with no planned maintenance, PDP G2AB Successful, Primary System Valve Closed, AFW Successful, Operator Depressurize Success RES23 RE 1.15E-01 2DG Failure with no planned maintenance, PDP G2AB Successful, Primary System Valve Closed, AFW Successful, Operator Depressurize Failure RES24 RE 1.12E-01 1DG Failure with no planned maintenance, PDP GlA Successful, Primary System Valve Closed, AFW Successful, Operator Depressurize Success Page 229 of 256
South Texas Project Risk-Informed GSI-191 Evaluation Volume 2: Probabilistic Risk Analysis RI-GSI191-V02 Revision 1 Table B.3-1 Master Frequency File Used for Point Estimate Event Tree Quantification (Continued)
SF Name Top Event SF Value Split Fraction Description ISF RES25 RE 1.12E-01 1DG Failure with no planned maintenance, PDP GlA Successful, Primary System Valve Closed, AFW Successful, Operator Depressurize Failure RES26 RE 3.18E-01 3DG Failure with no planned maintenance, Primary G3ABC System Valve not Closed, AFW Failure, Operator Depressurize Success RES27 RE 3.18E-01 3DG Failure with no planned maintenance, Primary G3ABC System Valve not Closed, AFW Failure, Operator Depressurize Failure RES28 RE 2.83E-01 2DG Failure with no planned maintenance, Primary G2AB System Valve not Closed, AFW Failure, Operator Depressurize Success RES29 RE 2.83E-01 2DG Failure with no planned maintenance, Primary G2AB System Valve not Closed, AFW Failure, Operator Depressurize Failure RES3 RE 1.21 E-01 3DG Failure with no planned maintenance, PDP G3ABC Failed, Primary System Valve Closed, AFW Successful, Operator Depressurize Failure RES30 RE 4.29E-01 1DG Failure with no planned maintenance, Primary GIA System Valve not Closed, AFW Failure, Operator Depressurize Success RES31 RE 4.29E-01 1DG Failure with no planned maintenance, Primary GlA System Valve not Closed, AFW Failure, Operator Depressurize Failure RES4 RE 1.15E-01 2DG Failure with no planned maintenance, PDP G2AB Failed, Primary System Valve Closed, AFW Successful, Operator Depressurize Success RES5 RE 1.20E-01 2DG Failure with no planned maintenance, PDP G2AB Failed, Primary System Valve Closed, AFW I_
Successful, Operator Depressurize Failure RES6 RE 1.13E-01 1DG Failure with no planned maintenance, PDP GlA Failed, Primary System Valve Closed, AFW Successful, Operator Depressurize Success Page 230 of 256
South Texas Project Risk-Informed GSI-191 Evaluation Volume 2: Probabilistic Risk Analysis RI-GSI 191 -V02 Revision 1 Table B.3-1 Master Frequency File Used for Point Estimate Event Tree Quantification (Continued)
SF Name Top Event SF Value Split Fraction Description ISF RES7 RE 1.20E-01 1 DG Failure with no planned maintenance, PDP GIA Failed, Primary System Valve Closed, AFW Successful, Operator Depressurize Failure RES8 RE 1.74E-01 3DG Failure with no planned maintenance, Primary G3ABC System Valve Not Closed, AFW Successful, Operator Depressurize Success RES9 RE 3.18E-01 3DG Failure with no planned maintenance, Primary G3ABC System Valve Not Closed, AFW Successful, Operator Depressurize Failure REW10 RE 3.87E-01 2DG Failure with no planned maintenance, Primary G2AB System Valve Not Closed, AFW Successful, Operator Depressurize Success REW1 1 RE 4.98E-01 2DG Failure with no planned maintenance, Primary G2AB System Valve Not Closed, AFW Successful, Operator Depressurize Failure REW12 RE 4.82E-01 1DG Failure with no planned maintenance, Primary GlA System Valve Not Closed, AFW Successful, Operator Depressurize Success REW13 RE 6.68E-01 1DG Failure with no planned maintenance, Primary GlA System Valve Not Closed, AFW Successful, Operator Depressurize Failure REW14 RE 5.18E-01 3DG Failure with no planned maintenance, Primary G3ABC System Valve Closed, AFW Failed, Operator Depressurize Success REW15 RE 5.18E-01 3DG Failure with no planned maintenance, Primary G3ABC System Valve Closed, AFW Failed, Operator Depressurize Failure REW16 RE 4.76E-01 2DG Failure with no planned maintenance, Primary G2AB System Valve Closed, AFW Failed, Operator Depressurize Success REW17 RE 4.76E-01 2DG Failure with no planned maintenance, Primary G2AB System Valve Closed, AFW Failed, Operator Depressurize Failure Page 231 of 256
South Texas Project Risk-Informed GSI-191 Evaluation Volume 2: Probabilistic Risk Analysis RI-GSI191-V02 Revision 1 Table B.3-1 Master Frequency File Used for Point Estimate Event Tree Quantification (Continued)
SF Name Top Event SF Value Split Fraction Description ISF REW18 RE 6.29E-01 1DG Failure with no planned maintenance, Primary GlA System Valve Closed, AFW Failed, Operator Depressurize Success REW19 RE 6.29E-01 1DG Failure with no planned maintenance, Primary G1A System Valve Closed, AFW Failed, Operator Depressurize Failure REW2 RE 2.41 E-01 3DG Failure with no planned maintenance, PDP G3ABC Failed, Primary System Valve Closed, AFW Successful, Operator Depressurize Success REW20 RE 2.36E-01 3DG Failure with no planned maintenance, PDP G3ABC Successful, Primary System Valve Closed, AFW Successful, Operator Depressurize Success REW21 RE 2.36E-01 3DG Failure with no planned maintenance, PDP G3ABC Successful, Primary System Valve Closed, AFW Successful, Operator Depressurize Failure REW22 RE 2.27E-01 2DG Failure with no planned maintenance, PDP G2AB Successful, Primary System Valve Closed, AFW Successful, Operator Depressurize Success REW23 RE 2.27E-01 2DG Failure with no planned maintenance, PDP G2AB Successful, Primary System Valve Closed, AFW Successful, Operator Depressurize Failure REW24 RE 2.55E-01 1DG Failure with no planned maintenance, PDP GlA Successful, Primary System Valve Closed, AFW Successful, Operator Depressurize Success REW25 RE 2.55E-01 1DG Failure with no planned maintenance, PDP G1A Successful, Primary System Valve Closed, AFW Successful, Operator Depressurize Failure REW26 RE 5.44E-01 3DG Failure with no planned maintenance, Primary G3ABC System Valve not Closed, AFW Failure, Operator Depressurize Success REW27 RE 5.44E-01 3DG Failure with no planned maintenance, Primary G3ABC System Valve not Closed, AFW Failure, Operator Depressurize Failure Page 232 of 256
South Texas Project Risk-Informed GSI-191 Evaluation Volume 2: Probabilistic Risk Analysis RI-GSI 191 -V02 Revision 1 Table B.3-1 Master Frequency File Used for Point Estimate Event Tree Quantification (Continued)
SF Name Top Event SF Value Split Fraction Description ISF REW28 RE 4.98E-01 2DG Failure with no planned maintenance, Primary G2AB System Valve not Closed, AFW Failure, Operator Depressurize Success REW29 RE 4.98E-01 2DG Failure with no planned maintenance, Primary G2AB System Valve not Closed, AFW Failure, Operator Depressurize Failure REW3 RE 2.68E-01 3DG Failure with no planned maintenance, PDP G3ABC Failed, Primary System Valve Closed, AFW Successful, Operator Depressurize Failure REW30 RE 6.68E-01 1DG Failure with no planned maintenance, Primary GlA System Valve not Closed, AFW Failure, Operator Depressurize Success REW31 RE 6.68E-01 1DG Failure with no planned maintenance, Primary GlA System Valve not Closed, AFW Failure, Operator Depressurize Failure REW4 RE 2.32E-01 2DG Failure with no planned maintenance, PDP G2AB Failed, Primary System Valve Closed, AFW Successful, Operator Depressurize Success REW5 RE 2.56E-01 2DG Failure with no planned maintenance, PDP G2AB Failed, Primary System Valve Closed, AFW Successful, Operator Depressurize Failure REW6 RE 2.62E-01 1DG Failure with no planned maintenance, PDP GlA Failed, Primary System Valve Closed, AFW Successful, Operator Depressurize Success REW7 RE 2.94E-01 1DG Failure with no planned maintenance, PDP GlA Failed, Primary System Valve Closed, AFW Successful, Operator Depressurize Failure REW8 RE 4.14E-01 3DG Failure with no planned maintenance, Primary G3ABC System Valve Not Closed, AFW Successful, SOperator Depressurize Success REW9 RE 5.44E-01 3DG Failure with no planned maintenance, Primary G3ABC System Valve Not Closed, AFW Successful, SOperator Depressurize Failure REY RE O.OOE+00 GS Page 233 of 256
South Texas Project Risk-Informed GSI-191 Evaluation Volume 2: Probabilistic Risk Analysis RI-GSI191-V02 Revision I Table B.3-1 Master Frequency File Used for Point Estimate Event Tree Quantification (Continued)
SF Name Top Event SF Value Split Fraction Description ISF REZ RE 1.OOE+00 GF RP1 RP 1.OOE+00 RCS PRESSURE AT VESSEL BREECH RP2 RP O.OOE+00
- DEFAULT RCS PRESS<200 PSIA @VB GIVEN RCS PRESS>2000 @UTAF.
RP3 RP O.OOE+00
- DEFAULT 200<RCS PRESS<600 PSIA @VB RP4 RP O.OOE+00
- DEFAULT 600<RCS PRESS<2000 PSIA @VB GIVEN RCS PRESS>2000 PSIA @UTAF
- RP5 RP 1.OOE+00
- DEFAULT RCS PRESS>2000 PSIA @VB GIVEN RCS PRESS>2000 PSIA @UTAF RPA RP 6.32E-01 STUCK OPEN PORV & SEAL LOCA, RCS PRESS<200 PSIA RPB RP 3.68E-01
- STUCK OPEN PORV & SEAL LOCA, 200<RCS PRESS<600 PSIA RPC RP O.OOE+00
- STUCK OPEN PORV & SEAL LOCA, 600<RCS PRESS<2000 PSIA RPD RP O.OOE+00
- STUCK OPEN PORV & SEAL LOCA, RCS PRESS>2000 PSIA RPDS1 RPDS 5.14E-02 RECOVERY OF PDS - LOSP RPDS2 RPDS 4.13E-02 RECOVERY OF PDS - LOEAB RPDS3 RPDS 4.54E-02 RECOVERY OF PDS - LOECW RPDSZ RPDS 1.OOE+00 GF RPE RP O.OOE+00
- DEFAULT RCS PRESS<200 PSIA @VB GIVEN 200<RCS PRESS<600 PSIA @UTAF RPF RP 1.OOE+00
- DEFAULT 200<RCS PRESS<600 PSIA @VB GIVEN 200<RCS PRESS<600 PSIA*UTAF RPG RP O.OOE+00
- DEFAULT 600<RCS PRESS<2000 PSIA @VB GIVEN 200<RCS PRESS<600 PSIA @UTAF RPH RP O.OOE+00
- DEFAULT RCS PRESS>2000 PSIA @VB GIVEN 200<RCS PRESS<600 PSIA @UTAF RPI RP O.OOE+00
- DEFAULT RCS PRESS<200 PSIA @VB GIVEN I_
600<RCS PRESS< 2000 PSIA @UTAF Page 234 of 256
South Texas Project Risk-Informed GSI-191 Evaluation Volume 2: Probabilistic Risk Analysis RI-GSI191-V02 Revision 1 Table B.3-1 Master Frequency File Used for Point Estimate Event Tree Quantification (Continued)
SF Name Top Event SF Value Split Fraction Description ISF RPJ RP O.OOE+00
- DEFAULT 200<RCS PRESS<600 PSIA @VB GIVEN 600<RCS PRESS<2000 PSIA @UTAF RPK RP 1.OOE+00
- DEFAULT 600<RCS PRESS<2000 PSIA @VB GIVEN 600<RCS PRESS<2000 PSIA @UTAF RPL RP O.OOE+00
- DEFAULT RCS PRESS>2000 PSIA @VB GIVEN 600<RCS PRESS<2000 PSIA @UTAF RPO RP 5.OOE-03
- RCS PRESS<200 PSIA @VB GIVEN A SEAL LOCA @UTAF RPP RP 5.35E-01
- 200<RCS PRESS<600 PSIA @VB GIVEN A SEAL LOCA @UTAF RPQ RP 1.70E-01
- 600<RCS PRESS<2000 PSIA @VB GIVEN A SEAL LOCA @UTAF RPR RP 2.90E-01
- RCS PRESS>2000 PSIA @VB GIVEN A STUCK OPEN PORV @UTAF RPS RP 5.OOE-01
- RCS PRESS<200 PSIA @VB GIVEN A STUCK OPEN PORV @UTAF RPT RP 5.OOE-01
- 200<RCS PRESS<600 PSIA @VB GIVEN A STUCK OPEN PORV @UTAF RPU RP O.OE+00
- 600<RCS PRESS<2000 PSIA @VB GIVEN A STUCK OPEN PORV @UTAF RPV RP O.OOE+00
- RCS PRESS>2000 PSIA @VB GIVEN A STUCK OPEN PORV @UTAF RPW RP 1.OOE+00
- RCS PRESS<200 PSIA @VB GIVEN THAT RCS PRESS<200 PSIA @UTAF RPX RP O.OOE+00
- 200<RCS PRESS<600 PSIA @VB GIVEN THAT RCS PRESS<200 PSIA @UTAF RPY RP O.OOE+00
- 600<RCS PRESS<2000 PSIA @VB GIVEN RCS PRESS<200 PSIA @UTAF RPZ RP O.OOE+00
- RCS PRESS>2000 PSIA @VB GIVEN RCS PRESS<200 PSIA @UTAF RTA RT 8.37E-06 REACTOR TRIP - POWER AVAILABLE AT M/G SETS RTB RT 3.57E-06 REACTOR TRIP WITH NO POWER AT M/G SETS -
LOSP Page 235 of 256
South Texas Project Risk-Informed GSI-191 Evaluation Volume 2: Probabilistic Risk Analysis RI-GS1 191 -V02 Revision 1 Table B.3-1 Master Frequency File Used for Point Estimate Event Tree Quantification (Continued)
SF Name Top Event SF Value Split Fraction Description ISF RTC RT 3.92E-06 MANUAL TRIP FROM CONTROL ROOM RTD RT 1.01E-03 REACTOR TRIP - SSPS "R" FAILED RTE RT 1.OOE-03 REACTOR TRIP - SSPS "S" FAILED RTF RT 8.03E-06 LOSS OF DC TRAIN A RTG RT 7.97E-06 LOSS OF DC TRAIN B RTH RT 4.14E-04 LOSS OF ALL DC TO SHUNT TRIP RTY RT O.OOE+00 GS RTZ RT 1.OOE+00 GF RX1A RX 4.95E-04 ONE RHR HEAT EXCHANGER OPERATES (A AVAILABLE)
RX1 B RX 4.95E-04 ONE RHR HEAT EXCHANGER OPERATES (B AVAILABLE)
RXlC RX 4.93E-04 ONE RHR HEAT EXCHANGER OPERATES (C AVAILABLE)
RX2AB RX 1.26E-05 AT LEAST ONE OF TWO RHR HEAT EXCHANGERS OPERATE (A & B AVAILABLE)
RX2AC RX 1.24E-05 AT LEAST ONE OF TWO RHR HEAT EXCHANGERS OPERATE (A & C AVAILABLE)
RX2BC RX 1.25E-05 AT LEAST ONE OF TWO RHR HEAT EXCHANGERS OPERATE (B & C AVAILABLE)
RX3 RX 3.04E-06 AT LEAST ONE OF THREE AVAILABLE TRAINS OF RHR HEAT EXCHANGERS OPERATE RXY RX O.OOE+00 GS RXZ RX 1.OOE+00 GF SlA 51 7.44E-01 1 OF 5 SG SRVS PROVIDE STEAM RELIEF - S2 S1B FAILED S1B
$1 1.30E-06 1 OF 5 SG SRVS PROVIDE STEAM RELIEF SlY 51 O.OOE+00 GS S1Z
$1 1.OOE+00 GF S2A S2 1.75E-06 FAILURE OF FOUR OR MORE SRVS TO PROVIDE STEAM RELIEF (SLOCA)
Page 236 of 256
South Texas Project Risk-Informed GSI-191 Evaluation Volume 2: Probabilistic Risk Analysis RI-GSI191-V02 Revision 1 Table B.3-1 Master Frequency File Used for Point Estimate Event Tree Quantification (Continued)
SF Name Top Event SF Value Split Fraction Description ISF S2Y S2 O.OOE+00 GS S2Z S2 1.OOE+00 GF SAC1 SAC 1.86E-05 MEAN - FREQ. - SEIS G LEVEL 1 SAC2 SAC 8.12E-04 MEAN - FREQ. - SEIS G LEVEL 2 SAC3 SAC 9.83E-03 MEAN - FREQ. - SEIS G LEVEL 3 SAC4 SAC 6.81E-02 MEAN - FREQ. - SEIS G LEVEL 4 SACY SAC O.OOE+00 FOR NON-SEISMIC EVENTS SAF1 SAF 1.15E-04 MEAN - FREQ. - SEIS G LEVEL 1 SAF2 SAF 3.96E-03 MEAN - FREQ. - SEIS G LEVEL 2 SAF3 SAF 3.56E-02 MEAN - FREQ. - SEIS G LEVEL 3 SAF4 SAF 1.81E-01 MEAN - FREQ. - SEIS G LEVEL 4 SAFY SAF O.OOE+00 FOR NON-SEISMIC EVENTS SCL1 SCL 1.67E-04 MEAN - FREQ. - SEIS G LEVEL 1 SCL2 SCL 6.33E-03 MEAN - FREQ. - SEIS G LEVEL 2 SCL3 SCL 6.50E-02 MEAN - FREQ. - SEIS G LEVEL 3 SCL4 SCL 3.80E-01 MEAN - FREQ. - SEIS G LEVEL 4 SCLY SCL O.OOE+00 FOR NON-SEISMIC EVENTS SCW1 SCW 1.21 E-04 MEAN - FREQ. - SEIS G LEVEL 1 SCW2 SCW 4.35E-03 MEAN - FREQ. - SEIS G LEVEL 2 SCW3 SCW 4.25E-02 MEAN - FREQ. - SEIS G LEVEL 3 SCW4 SCW 2.41 E-01 MEAN - FREQ. - SEIS G LEVEL 4 SCWY SCW O.OOE+00 FOR NON-SEISMIC EVENTS SDC1 SDC 5.03E-06 MEAN - FREQ. - SEIS G LEVEL 1 SDC2 SDC 2.89E-04 MEAN - FREQ. - SEIS G LEVEL 2 SDC3 SDC 4.86E-03 MEAN - FREQ. - SEIS G LEVEL 3 SDC4 SDC 4.27E-02 MEAN - FREQ. - SEIS G LEVEL 4 SDCY SDC O.OOE+00 FOR NON-SEISMIC EVENTS Page 237 of 256
South Texas Project Risk-Informed GSI-191 Evaluation Volume 2: Probabilistic Risk Analysis RI-GSI191-V02 Revision I Table B.3-1 Master Frequency File Used for Point Estimate Event Tree Quantification (Continued)
SF Name Top Event SF Value Split Fraction Description ISF SDG1 SDG 1.19E-04 MEAN - FREQ. - SEIS G LEVEL 1 SDG2 SDG 4.27E-03 MEAN - FREQ. - SEIS G LEVEL 2 SDG3 SDG 4.17E-02 MEAN - FREQ. - SEIS G LEVEL 3 SDG4 SDG 2.38E-01 MEAN - FREQ. - SEIS G LEVEL 4 SDGY SDG O.OOE+00 FOR NON-SEISMIC EVENTS SEA SE 2.61 E-06 SEAL INJECTION, ALL SUPPORT, PDP=B SEB SE 1.08E-01 CCW TO RCPs, NO SEAL INJECTION SEC SE 5.03E-03 SEAL INJECTION TO RCPs (PDP), NO CCW SED SE 5.10E-05 CCW TO RCPs, SEAL INJECTION, CCP=F SEE SE 6.91 E-05 LOOP, PDP=B SEF SE 1.08E-01 LOOP, NO SEAL INJECTION SEG SE 1.88E-03 LOOP, NO CCW SEH SE 5.16E-05 LOOP, CCW TO RCPs, CCP=F SEW1 SEW 7.50E-07 MEAN - FREQ. - SEIS G LEVEL 1 SEW2 SEW 7.34E-05 MEAN - FREQ. - SEIS G LEVEL 2 SEW3 SEW 2.11E-03 MEAN - FREQ. - SEIS G LEVEL 3 SEW4 SEW 2.63E-02 MEAN - FREQ. - SEIS G LEVEL 3 SEWY SEW O.OOE+00 FOR NON-SEISMIC EVENTS SEY SE O.OOE+00 GS SEZ SE 1.OOE+00 GF SFGSO GENST O.OOE+00 Used to Zero Out Fraction of Initiator Frequency SFMSO STATE O.OOE+00 INITIATOR NA TO MAINTENANCE STATE SFMS01 STATE 1.OOE+00 MAINTENANCE STATE 1 SFMS02 STATE 1.OOE+00 MAINTENANCE STATE 2 SFMS03 STATE 1.OOE+00 MAINTENANCE STATE 3 SGIA SGI 2.90E-05 SGI - TT=F OR SLB, ALL SUPPORT SGIB SGI 9.55E-04 SGI - TT=F DC+ESFAS A=F Page 238 of 256
South Texas Project Risk-Informed GSI-191 Evaluation Volume 2: Probabilistic Risk Analysis RI-GSI 191 -V02 Revision 1 Table B.3-1 Master Frequency File Used for Point Estimate Event Tree Quantification (Continued)
SF Name Top Event SF Value Split Fraction Description ISF SGIC SGI 9.98E-04 SGI - TT=F DC+ESFAS B=F SGID SGI 2.07E-05 SGI - ISOLATE A SG, ALL SUPPORT SGIE SGI 5.46E-04 SGI - ISOLATE A SG, DC+ESFAS A =F SGIF SGI 5.33E-04 SGI - ISOLATE A SG, DC+ESFAS B=F SGIG SGI 2.13E-05 SGI - ISOLATE B SG, ALL SUPPORT SGIH SGI 5.55E-04 SGI - ISOLATE B SG, DC+ESFAS A=F SGII SGI 5.47E-04 SGI - ISOLATE B SG, DC+ESFAS B=F SGIJ SGI 2.13E-05 SGI - ISOLATE C SG, ALL SUPPORT SGIK SGI 5.53E-04 SGI - ISOLATE C SG, DC+ESFAS A=F SGIL SGI 5.35E-04 SGI - ISOLATE C SG, DC+ESFAS B=F SGIM SGI 2.13E-05 SGI - ISOLATE D SG, ALL SUPPORT SGIN SGI 5.39E-04 SGI - ISOLATE D SG, DC+ESFAS A=F SGIO SGI 5.35E-04 SGI - ISOLATE D SG, DC+ESFAS B=F SGIY SGI O.OOE+00 GS SGIZ SGI 1.OOE+00 GF S138AA S138A 1.55E-04 S138 PATH A SIPA S138AY S138A O.OOE+00 GS S138AZ S138A 1.OOE+00 GF S138BA S138B 1.56E-04 S138 PATH B - S138A=S SIPB S138BB S138B 1.94E-04 S138 PATH B - S138A=F SIPAB S138BC S138B 1.56E-04 S138 PATH B - S138A=B SIPB S138BY S138B O.OOE+00 GS S138BZ S138B 1.OOE+00 GF S138CA S138C 1.55E-04 S138 PATH C - S138A=S, S138B=S SIPC S138CB S138C 1.96E-04 S138 PATH C - S138A=S, S138B=F SIPBC SI38CC S138C 1.94E-04 S138 PATH C - S138A=F, SI38B=S SIPAC S138CD S138C 2.29E-04 S138 PATH C - S138A=F, S138B=F SIPALL Page 239 of 256
South Texas Project Risk-Informed GSI-191 Evaluation Volume 2: Probabilistic Risk Analysis RI-GSI191-V02 Revision 1 Table B.3-1 Master Frequency File Used for Point Estimate Event Tree Quantification (Continued)
SF Name Top Event SF Value Split Fraction Description ISF SI38CE S138C 1.55E-04 S138 PATH C - SI38A=B, SI38B=S SIPC SI38CF S138C 1.96E-04 S138 PATH C - S138A=B, S138B=F SIPBC SI38CG S138C 1.55E-04 S138 PATH C - S138A=S, S138B=B SIPC SI38CH S138C 1.94E-04 S138 PATH C - S138A=F, S138B=B SIPAC S138CI SI38C 1.55E-04 S138 PATH C - S138A=B, S138B=B SIPC SI38CY S138C O.OOE+00 GS SI38CZ S138C 1.OOE+00 GF SICA SICOM 1.38E-03 SI COMMON TRAIN A FAILS SICAB SICOM 6.50E-06 SI COMMON TRAINS A, B SICABC SICOM 2.15E-06 SI COMMON TRAINS A, B, C SICAC SICOM 6.55E-06 SI COMMON TRAINS A, C FAIL SICB SICOM 1.35E-03 SI COMMON TRAIN B FAILS SICBC SICOM 6.53E-06 SI COMMON TRAINS B, C FAIL SICC SICOM 1.38E-03 SI COMMON TRAIN C FAILS SIPA S138 1.55E-04 S138 PATH A SIPAB S138 3.02E-08 S138 PATHS A, B SIPAC S138 3.02E-08 S138 PATHS A, C SIPALL S138 6.92E-12 S138 PATHS A,B,C SIPB S138 1.56E-04 S138 PATH B SIPBC S138 3.06E-08 S138 PATHS B, C SIPC SI38 1.55E-04 S138 PATH C SIRA SIREC 1.25E-03 SI RECIRC TRAIN A FAILS SIRAB SIREC 3.15E-05 SI RECIRC TRAINS A AND B FAIL SIRABC SIREC 1.92E-05 SI RECIRC TRAINS A, B, AND C FAIL SIRAC SIREC 3.17E-05 SI RECIRC TRAINS A AND C FAIL SIRB SIREC 1.25E-03 SI RECIRC TRAIN B FAILS SIRBC SIREC 3.13E-05 SI RECIRC TRAINS B AND C FAIL Page 240 of 256
South Texas Project Risk-Informed GSI-191 Evaluation Volume 2: Probabilistic Risk Analysis RI-GS19I-V02 Revision I Table B.3-1 Master Frequency File Used for Point Estimate Event Tree Quantification (Continued)
SF Name Top Event SF Value Split Fraction Description ISF SIRC SIREC 1.22E-03 SI RECIRC TRAIN C FAILS SIV1 SIV 4.16E-05 MEAN - FREQ. - SEIS G LEVEL 1 SIV2 SIV 1.75E-03 MEAN - FREQ. - SEIS G LEVEL 2 SIV3 SIV 1.94E-02 MEAN - FREQ. - SEIS G LEVEL 3 SIV4 SIV 1.19E-01 MEAN - FREQ. - SEIS G LEVEL 4 SIVY SIV O.OOE+00 FOR NON-SEISMIC EVENTS SIXA SICOM 1.53E-03 SI COMMON TRAIN A FAILS - LLOCA SIXAB SICOM 7.08E-06 SI COMMON TRAINS A, B FAIL - LLOCA SIXABC SICOM 2.13E-06 SI COMMON TRAINS A, B, C FAIL - LLOCA SIXAC SICOM 7.03E-06 SI COMMON TRAINS A, C FAIL - LLOCA SIXB SICOM 1.53E-03 SI COMMON TRAIN B FAILS - LLOCA SIXBC SICOM 6.99E-06 SI COMMON TRAINS B, C FAIL - LLOCA SIXC SICOM 1.53E-03 SI COMMON TRAIN C FAILS - LLOCA SLA SL 9.24E-03 FAIL TO ISOLATE SG A - STM REL, MSI=S SLB SL 9.23E-03 FAIL TO ISOLATE SG B - STM REL, MSI=S SLC SL 9.14E-03 FAIL TO ISOLATE SG C - STM REL, MSI=S SLD SL 9.80E-03 FAIL TO ISOLATE SG D - STM REL, MSI=S SLE SL 1.09E-01 FAIL TO ISOLATE SG A - WTR REL, MSI=S SLF SL 1.08E-01 FAIL TO ISOLATE SG B - WTR REL, MSI=S SLG SL 1.10E-01 FAIL TO ISOLATE SG C - WTR REL, MSI=S SLH SL 1.08E-01 FAIL TO ISOLATE SG D - WTR REL, MSI=S SLI SL 9.22E-03 FAIL TO ISOLATE SG A - STM REL, MSI=B SLIA SL 9.69E-03 FAIL TO ISOLATE SG A - STM REL, MSI=B, DA=F SLIB SL 9.64E-03 FAIL TO ISOLATE SG A - STM REL, MSI=B, DB=F SLJ SL 9.18E-03 FAIL TO ISOLATE SG B - STM REL, MSI=B SLJA SL 9.58E-03 FAIL TO ISOLATE SG B - STM REL, MSI=B, DA=F SLJB SL 9.66E-03 FAIL TO ISOLATE SG B - STM REL, MSI=B, DB=F Page 241 of 256
South Texas Project Risk-Informed GSI-191 Evaluation Volume 2: Probabilistic Risk Analysis RI-GSI191-V02 Revision I Table B.3-1 Master Frequency File Used for Point Estimate Event Tree Quantification (Continued)
SF Name Top Event SF Value Split Fraction Description ISF SLK SL 9.20E-03 FAIL TO ISOLATE SG C - STM REL, MSI=B SLKA SL 9.66E-03 FAIL TO ISOLATE SG C - STM REL, MSI=B, DA=F SLKB SL 9.77E-03 FAIL TO ISOLATE SG C - STM REL, MSI=B, DB=F SLL SL 9.81 E-03 FAIL TO ISOLATE SG D - STM REL, MSI=B SLLA SL 1.01 E-02 FAIL TO ISOLATE SG D - STM REL, MSI=B, DA=F SLLB SL 1.02E-02 FAIL TO ISOLATE SG D - STM REL, MSI=B, DB=F SLM SL 1.07E-01 FAIL TO ISOLATE SG A - WTR REL, MSI=B SLMA SL 1.09E-01 FAIL TO ISOLATE SG A - WTR REL, MSI=B, DA=F SLMB SL 1.10E-01 FAIL TO ISOLATE SG A - WTR REL, MSI=B, DB=F SLN SL 1.07E-01 FAIL TO ISOLATE SG B - WTR REL, MSI=B SLNA SL 1.08E-01 FAIL TO ISOLATE SG B - WTR REL, MSI=B, DA=F SLNB SL 1.08E-01 FAIL TO ISOLATE SG B - WTR REL, MSI=B, DB=F SLO SL 1.07E-01 FAIL TO ISOLATE SG C - VVTR REL, MSI=B SLOA SL 1.12E-01 FAIL TO ISOLATE SG C - WTR REL, MSI=B, DA=F SLOB SL 1.10E-01 FAIL TO ISOLATE SG C - WTR REL, MSI=B, DB=F SLP SL 1.11E-01 FAIL TO ISOLATE SG D - WTR REL, MSI=B SLPA SL 1.08E-01 FAIL TO ISOLATE SG D - WTR REL MSI=B, DA=F SLPB SL 1.09E-01 FAIL TO ISOLATE SG D - WTR REL, MSI=B, DB=F SLY SL 0.OOE+00 GS SLZ SL 1.OOE+00 GF SOG1 SOG 1.47E-02 MEAN - FREQ. - SEIS G LEVEL 1 SOG2 SOG 1.91E-01 MEAN - FREQ. - SEIS G LEVEL 2 SOG3 SOG 5.36E-01 MEAN - FREQ. - SEIS G LEVEL 3 SOG4 SOG 8.81E-01 MEAN - FREQ. - SEIS G LEVEL 4 SOGY SOG 0.OOE+00 FOR NON-SEISMIC EVENTS SPA SP 1.33E-07 1 OF 2 NORMAL SPRAY VALVES OR AUX SPRAY VALVE ACTUATES SPB SP 2.49E-05 1 OF 2 NORMAL SPRAY VALVES ACTUATES Page 242 of 256
South Texas Project Risk-Informed GSI-191 Evaluation Volume 2: Probabilistic Risk Analysis RI-GSI191-V02 Revision I Table B.3-1 Master Frequency File Used for Point Estimate Event Tree Quantification (Continued)
SF Name Top Event SF Value Split Fraction Description ISF SPC SP 5.35E-03 AUXILIARY SPRAY VALVE ACTUATES SPRA SPR 4.29E-04 SSPS TRAIN R - ONE SIGNAL SSC SPRB SPR 4.28E-04 TRAIN R - TWO SIGNALS SSE SPRC SPR 4.52E-04 TRAIN R - ONE SIGNAL, ONE PS-A SSK SPRD SPR 4.43E-04 TRAIN R - TWO SIGNALS, ONE PS-A SSM SPRY SPR O.OOE+00 GS SPRZ SPR 1.OOE+00 GF SPSA SPS 4.29E-04 SSPS TRAIN S - ONE SIGNAL SSR=S SSD SPSB SPS 1.68E-03 TRAIN S - ONE SIGNAL, SSR=F SSA SPSC SPS 4.29E-04 TRAIN S - ONE SIGNAL, SSR=B SSD SPSD SPS 4.30E-04 TRAIN S - TWO SIGNALS, SSR=S SSF SPSE SPS 4.54E-09 TRAIN S - TWO SIGNALS, SSR=F SSB SPSF SPS 4.30E-04 TRAIN S - TWO SIGNALS, SSR=B SSF SPSG SPS 4.29E-04 TRAIN S - ONE SIGNAL, 1 PS-A, SSR=S SSD SPSH SPS 1.58E-03 TRAIN S - ONE SIGNAL, 1 PS-A, SSR=F SSG SPSI SPS 4.48E-04 TRAIN S - ONE SIGNAL, 1 PS-C, SSR=S SSL SPSJ SPS 1.69E-03 TRAIN S - ONE SIGNAL, 1 PS-C, SSR=F SSH SPSK SPS 4.49E-04 TRAIN S - ONE SIGNAL, 1 PS-C, SSR=B SSL SPSL SPS 4.30E-04 TRAIN S - TWO SIGNALS, 1 PS-A, SSR=S SSF SPSM SPS 2.98E-06 TRAIN S - TWO SIGNALS, 1 PS-A, SSR=F SSI SPSN SPS 4.50E-04 TRAIN S - TWO SIGNALS, 1 PS-C, SSR=S SSN SPSO SPS 3.01E-06 TRAIN S - TWO SIGNALS, 1 PS-C, SSR=F SSJ SPSP SPS 4.50E-04 TRAIN S - TWO SIGNALS, 1 PS-C, SSR=B SSN SPSY SPS O.OOE+00 GS SPSZ SPS 1.OOE+00 GF SPY SP O.OOE+00 GS SPZ SP 1.OOE+00 GF Page 243 of 256
South Texas Project Risk-Informed GSI-191 Evaluation Volume 2: Probabilistic Risk Analysis RI-GSI 1 91-V02 Revision 1 Table B.3-1 Master Frequency File Used for Point Estimate Event Tree Quantification (Continued)
SF Name Top Event SF Value Split Fraction Description ISF SSA SSPS 7.19E-07 BOTH TRAINS - ONE SIGNAL SSB SSPS 1.94E-12 BOTH TRAINS - TWO SIGNALS SSC SSPS 4.29E-04 SSPS TRAIN R - ONE SIGNAL SSD SSPS 4.29E-04 SSPS TRAIN S - ONE SIGNAL SSE SSPS 4.28E-04 SSPS TRAIN R - TWO SIGNALS SSF SSPS 4.30E-04 SSPS TRAIN S - TWO SIGNALS SSG SSPS 7.16E-07 BOTH TRAINS - CHANNEL I=F, 1 SIGNAL SSH SSPS 7.26E-07 BOTH TRAINS - CHANNEL IV=F, 1 SIGNAL SSI SSPS 1.32E-09 BOTH TRAINS - CHANNEL I=F, 2 SIGNALS SSJ SSPS 1.29E-09 BOTH TRAINS - CHANNEL IV=F, 2 SIGNALS SSK SSPS 4.52E-04 SSPS TRAIN R - CHANNEL I=F, 1 SIGNAL SSL SSPS 4.49E-04 SSPS TRAIN S - CHANNEL IV=F, 1 SIGNAL SSM SSPS 4.43E-04 SSPS TRAIN R - CHANNEL I=F, 2 SIGNAL SSN SSPS 4.50E-04 SSPS TRAIN S - CHANNEL IV=F, 2 SIGNAL SSS1 SSS 8.32E-05 MEAN - FREQ. - SEIS G LEVEL 1 SSS2 SSS 3.50E-03 MEAN - FREQ. - SEIS G LEVEL 2 SSS3 SSS 3.88E-02 MEAN - FREQ. - SEIS G LEVEL 3 SSS4 SSS 2.38E-01 MEAN - FREQ. - SEIS G LEVEL 4 SSSY SSS O.OOE+00 FOR NON-SEISMIC EVENTS SULLI SUMP 2.45E-04 SUMP PLUGGING STATE 1, LARGE LOCA SULL22 SUMP 1.32E-03 SUMP PLUGGING STATE 22, LARGE LOCA SULL26 SUMP 9.55E-04 SUMP PLUGGING STATE 26, LARGE LOCA SULL43 SUMP 4.44E-03 SUMP PLUGGING STATE 43, LARGE LOCA SULL9 SUMP 5.39E-04 SUMP PLUGGING STATE 9, LARGE LOCA SUMLI SUMP O.OOE+00 SUMP PLUGGING STATE I MEDIUM LOCA SUML22 SUMP O.OOE+00 SUMP PLUGGING STATE 22, MEDIUM LOCA SUML26 SUMP O.OOE+00 SUMP PLUGGING STATE 26, MEDIUM LOCA Page 244 of 256
South Texas Project Risk-Informed GSI-191 Evaluation Volume 2: Probabilistic Risk Analysis RI-GSI 191 -V02 Revision 1 Table B.3-1 Master Frequency File Used for Point Estimate Event Tree Quantification (Continued)
SF Name Top Event SF Value Split Fraction Description ISF SUML43 SUMP O.OOE+00 SUMP PLUGGING STATE 43, MEDIUM LOCA SUML9 SUMP O.OOE+00 SUMP PLUGGING STATE 9, MEDIUM LOCA SUMPY SUMP O.OOE+00 no description entered SUMPZ SUMP 1.00E+00 no description entered SXAA SXA 3.99E-05 UNIT 1 STANDBY TRANSFORMER, ALL SUPPORT SXAY SXA O.OOE+00 GS SXAZ SXA 1.00E+00 GF SXBA SXB 3.93E-05 UNIT 2 STANDBY TRANSFORMER, ALL SUPPORT SXBY SXB O.OOE+00 GS SXBZ SXB 1.OOE+00 GF TIMEA GENST 9.03E-02 Fraction of Time Unit Assumed Shutdown TIMEG GENST 7.50E-03 Planned Maint Train D - TDAFW, SGPORV TMEBAB GENST 2.66E-01 No Planned Maint, Trains A, B Running TMEBBC GENST 2.66E-01 No Planned Maint, Trains B, C Running TMEBCA GENST 2.67E-01 No Planned Maint, Trains C, A Running TMECAB GENST 1.53E-02 Planned Maint Train C - Case 1, EW, CC, DG, CH, RH, RCFC, CVA TMECBC GENST 1.53E-02 Planned Maint Train A - Case 1, EW, CC, DG, CH, RH, RCFC, CVB TMECCA GENST 1.53E-02 Planned Maint Train B - Case 1, EW, CC, DG, CH, RH, RCFC TMEDAB GENST 4.80E-03 Planned Maint Train C - Case 2, CH, HE(EAB),
HE(CR)
TMEDBC GENST 4.80E-03 Planned Maint Train A - Case 2, CH, HE(EAB),
HE(CR)
TMEDCA GENST 4.80E-03 Planned Maint Train B - Case 2, CH, HE(EAB),
HE(CR)
TMEEAB GENST 7.50E-03 Planned Maint Train C - Case 3, LH, HH, CS, SICOM Page 245 of 256
South Texas Project Risk-Informed GSI-191 Evaluation Volume 2: Probabilistic Risk Analysis RI-GSI191-V02 Revision 1 Table B.3-1 Master Frequency File Used for Point Estimate Event Tree Quantification (Continued)
SF Name Top Event SF Value Split Fraction Description ISF TMEEBC GENST 7.50E-03 Planned Maint Train A - Case 3, LH, HH, CS, SICOM TMEECA GENST 7.50E-03 Planned Maint Train B - Case 3, LH, HH, CS, SICOM TMEFAB GENST 7.50E-03 Planned Maint Train C - MDAFW, SGPORV TMEFBC GENST 7.50E-03 Planned Maint Train A - MDAFW, SGPORV TMEFCA GENST 7.50E-03 Planned Maint Train B - MDAFW, SGPORV TTA TT 3.20E-04 TURBINE TRIP FAILS TTB TT 9.40E-03 TT FAILS - ESFAS A=F TTC TT 9.47E-03 TT FAILS - ESFAS B=F TTY TT O.OOE+00 GS TTZ TT 1.OOE+00 GF UAA UA 9.68E-04 UNIT AUX. TRANSFORMER - ALL SUPPORT UAY UA O.OOE+00 GS UAZ UA 1.OOE+00 GF VIA VI 1.10E-04 VESSEL INTEGRITY DURING PTS VIZ VI 1.OOE+00 GF WA1 WA 2.90E-04 ECW TRAIN A (WA) - RUN WA2 WA 1.37E-03 WA RESTART (LOOP)
WA3 WA 2.62E-03 WA START WAA WA 2.86E-04 WA RUN ECW101 WAB WA 1.36E-03 WA R/S ECW104 WAC WA 2.59E-03 WA START ECW107 WAY WA O.OOE+00 GS WAZ WA 1.OOE+00 GF WB1 WB 2.85E-04 WB RUN WB2 WB 1.38E-03 WB RESTART (LOOP)
WB3 WB 2.60E-03 WB START Page 246 of 256
South Texas Project Risk-Informed GSI-191 Evaluation Volume 2: Probabilistic Risk Analysis RI-GSI191-V02 Revision 1 Table B.3-1 Master Frequency File Used for Point Estimate Event Tree Quantification (Continued)
SF Name Top Event SF Value Split Fraction Description ISF WBA WB 2.87E-04 ECW B - WA RUN, WB RUN ECW102 WBB WB 1.22E-03 WA=F, WB RUN ECW201 WBC WB 1.36E-03 WA RUN, WB R/S ECW105 WBD WB 2.24E-03 WA=F, WB R/S ECW202 WBE WB 2.87E-04 WA R/S, WB RUN ECW102 WBF WB 4.75E-04 WA=F, WB RUN ECW203 WBG WB 1.35E-03 WA R/S, WB R/S (LOOP)
ECW105 WBH WB 1.OOE-02 WA=F, WB R/S ECW204 WBI WB 2.59E-03 WA RUN, WB START ECW108 WBJ WB 3.54E-03 WA=F, WB START ECW205 WBK WB 2.58E-03 WA R/S, WB START ECW108 WBL WB 1.11E-02 WA=F, WB START ECW206 WBM WB 2.87E-04 WA START, WB RUN ECW102 WBN WB 3.92E-04 WA=F, WB RUN ECW207 WBO WB 1.35E-03 WA START, WB R/S ECW105 WBP WB 5.84E-03 WA=F, WB R/S ECW208 WBQ WB 2.87E-04 WA=B, WB RUN ECW1 02 WBR WB 1.36E-03 WA=B, WB R/S ECW105 WBS WB 2.59E-03 WA=B, WB START ECW108 WBY WB 0.OOE+00 GS WBZ WB 1.OOE+00 GF WCl WC 2.84E-04 WC RUN WC2 WC 1.37E-03 WC RESTART (LOOP)
WC3 WC 2.59E-03 WC START WCA WC 2.58E-03 ECW C -WA RUN, WB RUN, WC START ECW109 WCAA WC 2.86E-04 WA R/S, WB START, WC RUN ECW103 WCAB WC 3.77E-04 WA=S, WB=F, WC RUN ECW223 Page 247 of 256
South Texas Project Risk-Informed GSI-191 Evaluation Volume 2: Probabilistic Risk Analysis RI-GSI 19 1-V02 Revision I Table B.3-1 Master Frequency File Used for Point Estimate Event Tree Quantification (Continued)
SF Name Top Event SF Value Split Fraction Description ISF WCAC WC 4.74E-04 WA=F, WB=S, WC RUN ECW211 WCAD WC 2.21 E-03 WA=F, WB=F, WC RUN ECW307 WCAE WC 1.34E-03 WA R/S, WB START, WC R/S ECW106 WCAF WC 4.39E-03 WA=S, WB=F, WC R/S ECW224 WCAG WC 7.42E-03 WA=F, WB=S, WC R/S ECW212 WCAH WC 2.17E-01 WA=F, WB=F, WC R/S ECW308 WCAI WC 2.86E-04 WA START, WB RUN, WC RUN ECW103 WCAJ WC 1.11E-03 WA=S, WB=F, WC RUN ECW217 WCAK WC 3.83E-04 WA=F, WB=S, WC RUN ECW215 WCAL WC 2.86E-02 WA=F, WB=F, WC RUN ECW309 WCAM WC 1.34E-03 WA START, WB RUN, WC R/S ECW106 WCAN WC 2.18E-03 WA=S, WB=F, WC R/S ECW218 WCAO WC 5.73E-03 WA=F, WB=S, WC R/S ECW216 WCAP WC 3.29E-02 WA=F, WB=F, WC R/S ECW310 WCAQ WC 2.86E-04 WA START, WB R/S, WC RUN ECW103 WCAR WC 4.57E-04 WA=S, WB=F, WC RUN ECW219 WCAS WC 3.84E-04 WA=F, WB=S, WC RUN ECW215 WCAT WC 2.18E-03 WA=F, WB=F, WC RUN ECW311 WCAU WC 1.33E-03 WA START, WB R/S, WC R/S ECW106 WCAV WC 7.34E-03 WA=S, WB=F, WC R/S ECW220 WCAW WC 4.47E-03 WA=F, WB=S, WC R/S ECW216 WCAX WC 2.22E-01 WA=F, WB=F, WC R/S ECW312 WCB WC 3.42E-03 WA=S, WB=F, WC START ECW221 WCBA WC 2.86E-04 WA RUN, WB=B, WC RUN ECW103 WCBB WC 1.20E-03 WA=F, WB=B, WC RUN ECW209 WCBC WC 1.35E-03 WA RUN, WB=B, WC R/S ECW106 WCBD WC 2.32E-03 WA=F, WB=B, WC R/S ECW210 Page 248 of 256
South Texas Project Risk-Informed GSI-191 Evaluation Volume 2: Probabilistic Risk Analysis RI-GS1191-V02 Revision 1 Table B.3-1 Master Frequency File Used for Point Estimate Event Tree Quantification (Continued)
SF Name Top Event SF Value Split Fraction Description ISF WCBE WC 2.86E-04 WA R/S, WB=B, WC RUN ECW103 WCBF WC 4.94E-04 WA=F, WB=B, WC RUN ECW211 WCBG WC 1.34E-03 WA R/S, WB=B, WC R/S ECW106 WCBH WC 9.76E-03 WA=F, WB=B, WC R/S ECW212 WCBI WC 2.58E-03 WA RUN, WB=B, WC START ECW109 WCBJ WC 3.56E-03 WA=F, WB=B, WC START ECW213 WCBK WC 2.57E-03 WA R/S, WB=B, WC START ECW109 WCBL WC 1.08E-02 WA=F, WB=B, WC START ECW214 WCBM WC 2.86E-04 WA START, WB=B, WC RUN ECW103 WCBN WC 3.94E-04 WA=F, WB=B, WC RUN ECW215 WCBO WC 1.34E-03 WA START, WB=B, WC R/S ECW106 WCBP WC 5.74E-03 WA=F, WB=B, WC R/S ECW216 WCBQ WC 2.86E-04 WA=B, WB RUN, WC RUN ECW103 WCBR WC 1.21 E-03 WA=B, WB=F, WC RUN ECW217 WCBS WC 1.35E-03 WA=B, WB RUN, WC R/S ECW106 WCBT WC 2.28E-03 WA=B, WB=F, WC R/S ECW218 WCBU WC 2.86E-04 WA=B, WB R/S, WC RUN ECW103 WCBV WC 4.76E-04 WA=B, WB=F, WC RUN ECW219 WCBW WC 1.34E-03 WA=B, WB R/S, WC R/S ECW106 WCBX WC 9.72E-03 WA=B, WB=F, WC R/S ECW220 WCC WC 3.47E-03 WA=F, WB=S, WC START ECW213 WCCA WC 2.58E-03 WA=B, WB RUN, WC START ECW109 WCCB WC 3.52E-03 WA=B, WB=F, WC START ECW221 WCCC WC 2.57E-03 WA=B, WB R/S, WC START ECW109 WCCD WC 1.06E-02 WA=B, WB=F, WC START ECW222 WCCE WC 2.86E-04 WA=B, WB START, WC RUN ECW1 03 WCCF WC 3.88E-04 WA=B, WB=F, WC RUN ECW223 Page 249 of 256
South Texas Project Risk-Informed GSI-191 Evaluation Volume 2: Probabilistic Risk Analysis RI-GSI191-V02 Revision 1 Table B.3-1 Master Frequency File Used for Point Estimate Event Tree Quantification (Continued)
SF Name Top Event SF Value Split Fraction Description ISF WCCG WC 1.34E-03 WA=B, WB START, WC R/S ECW106 WCCH WC 5.63E-03 WA=B, WB=F, WC R/S ECW224 WCCI WC 2.87E-04 WA=B, WB=B, WC RUN ECW103 WCCJ WC 1.35E-03 WA=B, WB=B, WC R/S ECW106 WCCK WC 2.58E-03 WA=B, WB=B, WC START ECW109 WCD WC 8.27E-02 WA=F, WB=F, WC START ECW301 WCE WC 2.57E-03 WA RUN, WB R/S, WC START ECW109 WCF WC 1.05E-02 WA=S, WB=F, WC START ECW222 WCG WC 3.46E-03 WA=F, WB=S, WC START ECW213 WCH WC 5.12E-02 WA=F, WB=F, WC START ECW302 WCl WC 2.57E-03 WA R/S, WB RUN, WC START ECW109 wCJ WC 3.41E-03 WA=S, WB=F, WC START ECW221 WCK WC 1.08E-02 WA=F, WB=S, WC START ECW214 WCL WC 5.31 E-02 WA=F, WB=F, WC START ECW303 WCM WC 2.56E-03 WA R/S, WB R/S, WC START ECW109 WCN WC 8.25E-03 WA=S, WB=F, WC START ECW222 WCO WC 8.47E-03 WA=F, WB=S, WC START ECW214 WCP WC 2.39E-01 WA=F, WB=F, WC START ECW304 WCQ WC 2.86E-04 WA RUN, WB START, WC RUN ECW103 WCR WC 3.76E-04 WA=S, WB=F, WC RUN ECW223 WCS WC 1.10E-03 WA=F, WB=S, WC RUN ECW209 WCT WC 2.93E-02 WA=F, WB=F, WC RUN ECW305 WCU WC 1.34E-03 WA RUN, WB START, WC R/S ECW106 WCV WC 5.62E-03 WA=S, WB=F, WC R/S ECW224 WCW WC 2.21 E-03 WA=F, WB=S, WC R/S ECW210 WCX WC 3.40E-02 WA=F, WB=F, WC R/S ECW306 WCY WC O.OOE+00 GS Page 250 of 256
South Texas Project Risk-Informed GSI-191 Evaluation Volume 2: Probabilistic Risk Analysis RI-GSI191-V02 Revision I Table B.3-1 Master Frequency File Used for Point Estimate Event Tree Quantification (Continued)
SF Name Top Event SF Value Split Fraction Description ISF WCZ WC 1.OOE+00 GF WI1A WI 3.60E-03 PUMP A DISCHARGES TO SPRAY HEADER WI1B WI 3.47E-03 PUMP B DISCHARGES TO SPRAY HEADER Wl1C WI 3.62E-03 PUMP C DISCHARGES TO SPRAY HEADER WI2AB WI 1.18E-04 PUMPS A AND B DISCHARGE TO SPRAY HEADERS WI2AC WI 1.17E-04 PUMPS A AND C DISCHARGE TO SPRAY HEADERS WI2BC WI 1.1 8E-04 PUMPS B AND C DISCHARGE TO SPRAY HEADERS W13 WI 3.38E-05 CS INJECTION (CSI) -ALL SUPPORT WIA1 WI 3.44E-05 CSI - ONE SSPS (R)
WIA2 WI 3.41 E-05 CSI - ONE SSPS (S)
WIC3 WI 9.64E-01 THREE PUMPS - CSR FAILS (CSR3)
W13 WICA WI 8.20E-01 PUMP A, CSR FAILS (CS1A)
W1lA WICAB WI 9.41E-01 2 PUMPS (A, B), CSR FAILS (CS2AB)
WI2AB WICAC WI 9.05E-01 2 PUMPS (A, C), CSR FAILS (CS2AC)
WI2AC WICB WI 8.23E-01 PUMP B, CSR FAILS (CS1B)
WI1B WICBC WI 9.27E-01 2 PUMPS (B, C), CSR FAILS (CS2BC)
WI2BC WICC WI 8.24E-01 PUMP C, CSR FAILS (CS1C)
WI1C WIY WI O.OOE+00 GS WIZ WI 1.OOE+00 GF X2A X2 1.OOE-01 NO HPME AT VESSEL BREACH X2B X2 1.OOE+00 HPME AT VESSEL BREACH XRA XR O.OOE+00 NO LATE HYDROGEN BURN OCCURS XRG XR 1.OOE+00 NO RECIRC COOLING & RCFCS FAILED OR DESTROYED BY LATE BURN XTMO UET O.OOE+00 NON UET SEQUENCES XTMA UET 2.19E-01 UET1 BRANCH Page 251 of 256
South Texas Project Risk-Informed GSI-191 Evaluation Volume 2: Probabilistic Risk Analysis RI-GSI191-V02 Revision 1 Table B.3-1 Master Frequency File Used for Point Estimate Event Tree Quantification (Continued)
SF Name Top Event SF Value Split Fraction Description ISF XTMB UET 3.39E-01 UET2 BRANCH XTMC UET 4.74E-01 UET3 BRANCH XTMD UET 2.66E-01 UET4 BRANCH XTME UET 3.83E-01 UET5 BRANCH XTMF UET 5.16E-01 UET6 BRANCH Page 252 of 256
South Texas Project Risk-Informed GSI-191 Evaluation Volume 2: Probabilistic Risk Analysis RI-GSI191-V02 Revision 1 B.4 LOCA Frequencies Table B.4-1 displays the LOCA exceedance frequencies as a function of break diameter used in the PRA quantification. The uncertainty was represented by 100 frequency exceedance curves according to a Bounded Johnson distribution fit to the NUREG-1829 uncertainty data at three break sizes. Exceedance frequency values are also provided at 7 inches and 10 inches, but they are artificial. They are included only to allow the RISKMAN software to determine an interval frequency for large LOCAs, i.e., for greater than 6-inch diameter breaks where the upper size limit has an effective exceedance frequency of approximately zero. For example, the medium LOCA mean interval frequency is 3.1 E-4 minus 5.2E-6, or 3.05E-4 per year.
When performing the Monte Carlo uncertainty propagation, whose results are presented in Tables 4-4 and 4-5, a single exceedance curve was chosen each sample and the medium and large LOCA frequencies for that sample were obtained by subtraction using the same percentile for the exceedance curve.
Table B.4-1 LOCA Exceedance Frequencies (per year)
Break Sizes (diameter inches)
Curve Curve We 0.5" 2"
6" 7"
10" Weights 1
1.OOE-03 4.78E-05 2.41E-06 3.88E-08 1.OOE-13 1.OOE-15 2
1.OOE-03 4.87E-05 2.47E-06 3.97E-08 1.OOE-13 1.OOE-15 3
1.OOE-03 4.95E-05 2.52E-06 4.05E-08 1.OOE-13 1.OOE-15 4
1.OOE-03 5.03E-05 2.57E-06 4.13E-08 1.OOE-13 1.OOE-15 5
1.00E-03 5.09E-05 2.61E-06 4.20E-08 1.00E-13 1.OOE-15 6
1.OOE-03 5.16E-05 2.66E-06 4.27E-08 1.00E-13 1.OOE-15 7
1.OOE-03 5.22E-05 2.70E-06 4.34E-08 1.OOE-13 1.OOE-15 8
1.OOE-03 5.29E-05 2.74E-06 4.41E-08 1.OOE-13 1.OOE-15 9
1.OOE-03 5.35E-05 2.79E-06 4.48E-08 1.OOE-13 1.OOE-15 10 1.OOE-03 5.40E-05 2.83E-06 4.55E-08 1.OOE-13 1.OOE-15 11 2.OOE-03 5.52E-05 2.91E-06 4.68E-08 1.OOE-13 1.OOE-15 12 2.OOE-03 5.63E-05 2.99E-06 4.82E-08 1.OOE-13 1.OOE-15 13 2.OOE-03 5.74E-05 3.08E-06 4.95E-08 1.OOE-13 1.O0E-15 14 2.OOE-03 5.85E-05 3.16E-06 5.08E-08 1.OOE-13 1.00E-15 15 2.OOE-03 5.96E-05 3.24E-06 5.22E-08 1.OOE-13 1.OOE-15 16 2.OOE-03 6.07E-05 3.33E-06 5.35E-08 1.00E-13 1.OOE-15 17 2.OOE-03 6.17E-05 3.41E-06 5.49E-08 1.OOE-13 1.OOE-15 18 2.OOE-03 6.28E-05 3.50E-06 5.63E-08 1.OOE-13 1.OOE-15 19 2.OOE-03 6.39E-05 3.58E-06 5.77E-08 1.OOE-13 1.OOE-15 20 2.OOE-03 6.49E-05 3.67E-06 5.90E-08 1.00E-13 1.OOE-15 21 4.OOE-03 6.71E-05 3.84E-06 6.19E-08 1.OOE-13 1.OOE-15 Page 253 of 256
South Texas Project Risk-Informed GSI-191 Evaluation Volume 2: Probabilistic Risk Analysis RI-GSI191-V02 Revision I Table B.4-1 LOCA Exceedance Frequencies (per year) (Continued)
Break Sizes (diameter inches)
Curve Curve 0.5" 2"
6" 7"
10" Weights 22 4.OOE-03 6.92E-05 4.02E-06 6.48E-08 1.OOE-13 1.OOE-15 23 4.OOE-03 7.14E-05 4.20E-06 6.77E-08 1.OOE-13 1.OOE-15 24 4.OOE-03 7.36E-05 4.39E-06 7.07E-08 1.OOE-13 1.OOE-15 25 4.OOE-03 7.57E-05 4.57E-06 7.38E-08 1.OOE-13 1.OOE-15 26 1.OOE-02 8.13E-05 5.06E-06 8.17E-08 1.OOE-13 1.OOE-15 27 1.OOE-02 8.71E-05 5.58E-06 9.01E-08 1.OOE-13 1.O0E-15 28 1.OOE-02 9.30E-05 6.12E-06 9.89E-08 1.OOE-13 1.OOE-15 29 1.OOE-02 9.91E-05 6.69E-06 1.08E-07 1.OOE-13 1.OOE-15 30 1.OOE-02 1.05E-04 7.29E-06 1.18E-07 1.OOE-13 1.OOE-15 31 2.OOE-02 1.19E-04 8.59E-06 1.39E-07 1.OOE-13 1.OOE-15 32 2.OOE-02 1.33E-04 1.OOE-05 1.63E-07 1.OOE-13 1.OOE-15 33 2.OOE-02 1.48E-04 1.16E-05 1.88E-07 1.OOE-13 1.OOE-15 34 2.OOE-02 1.65E-04 1.33E-05 2.17E-07 1.OOE-13 1.OOE-15 35 2.OOE-02 1.83E-04 1.52E-05 2.48E-07 1.OOE-13 1.OOE-15 36 2.OOE-02 2.02E-04 1.73E-05 2.83E-07 1.OOE-13 1.OOE-15 37 2.OOE-02 2.22E-04 1.97E-05 3.211E-07 1.OOE-13 1.OOE-15 38 2.OOE-02 2.45E-04 2.22E-05 3.62E-07 1.OOE-13 1.OOE-15 39 2.OOE-02 2.68E-04 2.50E-05 4.08E-07 1.OOE-13 1.OOE-15 40 2.OOE-02 2.94E-04 2.80E-05 4.58E-07 1.OOE-13 1.O0E-15 41 2.OOE-02 3.22E-04 3.13E-05 5.13E-07 1.OOE-13 1.OOE-15 42 2.OOE-02 3.52E-04 3.50E-05 5.74E-07 1.OOE-13 1.OOE-15 43 2.OOE-02 3.84E-04 3.90E-05 6.41E-07 1.OOE-13 1.OOE-15 44 2.OOE-02 4.19E-04 4.35E-05 7.14E-07 1.OOE-13 1.00E-15 45 2.OOE-02 4.57E-04 4.83E-05 7.94E-07 1.OOE-13 1.OOE-15 46 2.OOE-02 4.99E-04 5.37E-05 8.83E-07 1.OOE-13 1.OOE-15 47 2.OOE-02 5.43E-04 5.96E-05 9.81E-07 1.OOE-13 1.OOE-15 48 2.OOE-02 5.92E-04 6.61E-05 1.09E-06 1.OOE-13 1.OOE-15 49 2.OOE-02 6.44E-04 7.33E-05 1.21E-06 1.OOE-13 1.OOE-15 50 2.OOE-02 7.02E-04 8.13E-05 1.34E-06 1.OOE-13 1.OOE-15 51 2.OOE-02 7.64E-04 9.01E-05 1.49E-06 1.OOE-13 1.OOE-15 52 2.OOE-02 8.33E-04 9.99E-05 1.65E-06 1.OOE-13 1.OOE-15 53 2.OOE-02 9.08E-04 1.11E-04 1.83E-06 1.OOE-13 1.OOE-15 54 2.OOE-02 9.90E-04 1.23E-04 2.04E-06 1.OOE-13 1.OOE-15 55 2.OOE-02 1.08E-03 1.37E-04 2.26E-06 1.OOE-13 1.OOE-15 56 2.OOE-02 1.188E-03 1.52E-04 2.52E-06 1.OOE-13 1.OOE-15 Page 254 of 256
South Texas Project Risk-Informed GSI-191 Evaluation Volume 2: Probabilistic Risk Analysis RI-GSI191-V02 Revision 1 Table B.4-1 LOCA Exceedance Frequencies (per year) (Continued)
Break Sizes (diameter inches)
Curve Curve We 0.5" 2"
6" 7"
10."
Weights 57 2.OOE-02 1.29E-03 1.69E-04 2.81E-06 1.OOE-13 1.OOE-15 58 2.OOE-02 1.42E-03 1.89E-04 3.13E-06 1.OOE-13 1.OOE-15 59 2.OOE-02 1.55E-03 2.11E-04 3.50E-06 1.OOE-13 1.OOE-15 60 2.OOE-02 1.71E-03 2.36E-04 3.93E-06 1.OOE-13 1.OE-15 61 2.OOE-02 1.88E-03 2.65E-04 4.41E-06 1.OOE-13 1.O0E-15 62 2.OOE-02 2.07E-03 2.98E-04 4.97E-06 1.OOE-13 1.OOE-15 63 2.OOE-02 2.30E-03 3.37E-04 5.61E-06 1.OOE-13 1.OOE-15 64 2.OOE-02 2.55E-03 3.82E-04 6.37E-06 1.OOE-13 1.OOE-15 65 2.OOE-02 2.84E-03 4.34E-04 7.26E-06 1.OOE-13 1.OOE-15 66 2.OOE-02 3.18E-03 4.97E-04 8.31E-06 1.OOE-13 1.OOE-15 67 2.OOE-02 3.57E-03 5.72E-04 9.57E-06 1.OOE-13 1.OOE-15 68 2.OOE-02 4.04E-03 6.62E-04
- 1. 11E-05 1.OOE-13 1.OOE-15 69 2.OOE-02 4.60E-03 7.73E-04 1.30E-05 1.OOE-13 1.OOE-15 70 2.OOE-02 5.28E-03 9.12E-04 1.53E-05 1.OOE-13 1.O0E-15 71 1.OOE-02 5.69E-03 9.95E-04 1.67E-05 1.OOE-13 1.OOE-15 72 1.00E-02 6.14E-03 1.09E-03 1.83E-05 1.OOE-13 1.OOE-15 73 1.OOE-02 6.65E-03 1.20E-03 2.01E-05 1.OOE-13 1.OOE-15 74 1.OOE-02 7.23E-03 1.32E-03 2.22E-05 1.OOE-13 1.OOE-15 75 1.OOE-02 7.91E-03 1.46E-03 2.46E-05 1.OOE-13 1.OOE-15 76 4.OOE-03 8.21E-03 1.52E-03 2.57E-05 1.OOE-13 1.OOE-15 77 4.OOE-03 8.53E-03 1.59E-03 2.69E-05 1.OOE-13 1.OOE-15 78 4.OOE-03 8.88E-03 1.67E-03 2.81E-05 1.OOE-13 1.OOE-15 79 4.OOE-03 9.25E-03 1.74E-03 2.94E-05 1.OOE-13 1.OOE-15 80 4.OOE-03 9.66E-03 1.83E-03 3.09E-05 1.OOE-13 1.OE-15 81 2.OOE-03 9.87E-03 1.87E-03 3.16E-05 1.OOE-13 1.O0E-15 82 2.OOE-03 1.01E-02 1.92E-03 3.24E-05 1.OOE-13 1.OOE-15 83 2.0OE-03 1.03E-02 1.97E-03 3.32E-05 1.OOE-13 1.OOE-15 84 2.OOE-03 1.06E-02 2.02E-03 3.41E-05 1.OOE-13 1.OOE-15 85 2.OOE-03 1.08E-02 2.07E-03 3.50E-05 1.OOE-13 1.OOE-15 86 2.OOE-03 1.11E-02 2.13E-03 3.59E-05 1.OOE-13 1.OOE-15 87 2.OOE-03 1.14E-02 2.19E-03 3.69E-05 1.OOE-13 1.OOE-15 88 2.OOE-03 1.17E-02 2.25E-03 3.80E-05 1.OOE-13 1.OOE-15 89 2.00E-03 1.21 E-02 2.311E-03 3.911E-05 1.OOE-13 1.OOE-15 90 2.OOE-03 1.24E-02 2.38E-03 4.02E-05 1.OOE-13 1.OOE-15 91 1.OOE-03 1.26E-02 2.42E-03 4.09E-05 1.OOE-13 1.OOE-15 92 1.OOE-03 1.28E-02 2.46E-03 4.15E-05 1.OOE-13 1.OOE-15 Page 255 of 256
South Texas Project Risk-Informed GSI-191 Evaluation Volume 2: Probabilistic Risk Analysis RI-GSI 191-V02 Revision 1 Table B.4-1 LOCA Exceedance Frequencies (per year) (Continued)
Break Sizes (diameter inches)
Curve Curve We 0.5" 2"
6" 7"
10" Weights 93 1.OOE-03 1.31E-02 2.50E-03 4.22E-05 1.OOE-13 1.O0E-15 94 1.OOE-03 1.33E-02 2.54E-03 4.29E-05 1OOE-13 1.00E-15 95 1.OOE-03 1.35E-02 2.58E-03 4.36E-05 1.OOE-13 1.OOE-15 96 1.OOE-03 1.38E-02 2.63E-03 4.44E-05 1.OOE-13 1.OOE-15 97 1.OOE-03 1.41E-02 2.68E-03 4.53E-05 1.OOE-13 1.OOE-15 98 1.OOE-03 1.45E-02 2.74E-03 4.62E-05 1.OOE-13 1.OOE-15 99 1.OOE-03 1.49E-02 2.80E-03 4.73E-05 1.OOE-13 1.O0E-15 100 1.OOE-03 1.59E-02 2.92E-03 4.93E-05 1.00E-13 1.OOE-15 MEAN 1.OOE+00 1.90E-03 3.10E-04 5.20E-06 O.OOE+00 O.OOE+00 Page 256 of 256