GNRO-2013/00001, Response to Electronic Request for Additional Information Supporting Completion of Safety Evaluation for the License Amendment Request for Revision of Technical Specification Allowable Value for Primary Containment and Drywell.

From kanterella
(Redirected from ML13031A352)
Jump to navigation Jump to search

Response to Electronic Request for Additional Information Supporting Completion of Safety Evaluation for the License Amendment Request for Revision of Technical Specification Allowable Value for Primary Containment and Drywell.
ML13031A352
Person / Time
Site: Grand Gulf Entergy icon.png
Issue date: 01/30/2013
From: Kevin Mulligan
Entergy Operations
To:
Document Control Desk, Office of Nuclear Reactor Regulation
References
GNRO-2013/00001
Download: ML13031A352 (183)


Text

~Entergy GNRO-2013/00001 January 30, 2013 u.s. Nuclear Regulatory Commission Attn: Document Control Desk Washington, DC 20555-0001 Entergy Operations, Inc.

P. O. Box 756 Port Gibson, MS 39150 Kevin J. Mulligan Vice President, Operations Grand Gulf Nuclear Station Tel. (601) 437-7500

SUBJECT:

Response to Electronic Request For Additional Information Supporting Completion of the Safety Evaluation for the License Amendment Request for Revision of Technical Specification Allowable Value for Primary Containment and Drywellisolation Instrumentation Function 3.c "RCIC Steam Supply Line Pressure - Low. II Grand Gulf Nuclear Station, Unit 1 Docket No. 50-416 License No. NPF-29

REFERENCE:

1.

License Amendment Request for Revision of Technical Specification Allowable Value for Primary Containment and Drywellisolation Instrumentation Function 3.c "RCIC Steam Supply Line Pressure - Low." dated November 9,2012 (Accession No. ML12318A119) 2.

Electronic Request For Additional Information Supporting Completion of the Safety Evaluation for the License Amendment Request for Revision of Technical SPecification Allowable Value for Primary Containment and Drywellisolation Instrumentation Function 3.c "RCIC Steam Supply Line Pressure - Low. ff dated January 2, 2013

Dear Sir or Madam:

Entergy Operations, Inc. is providing, in the Attachments, the response to Reference 2 Request for Additional Information.

This letter contains no new commitments. If you have any questions or require additional information, please contact Jeffery A. Seiter at 601-437-2344.

I declare under penalty of perjury that the foregoing is true and correct. Executed on January 30, 2013.

Sincerely,

.~----

KJM/jas Attachments and cc: (see next page) 2

GNRO-2013/00001 Page 2 of 2 : : : : : :

Response to Electronic Request For Additional Information Supporting Completion of the Safety Evaluation for the License Amendment Request for Revision of Technical Specification Allowable Value for Primary Containment and Drywell Isolation Instrumentation Function 3.c "RCIC Steam Supply Line Pressure - Low."

Copy of GEXI 2000-00134 Rosemount Fax Dated 9/29/94 Copy of JC-Q1111-09019 Page 30 of 01-S-06-12 Page 63 of EN-OP-104 cc:

U.S. Nuclear Regulatory Commission ATTN: Mr. John Boska, NRR/DORL Mail Stop OWFN/8 C2 11555 Rockville Pike Rockville, MD 20852-2378 U. S. Nuclear Regulatory Commission ATTN: Mr. Elmo E. Collins, Jr.

Regional Administrator, Region IV 1600 East Lamar Boulevard Arlington, TX 76011-4511 U. S. Nuclear Regulatory Commission ATTN: Mr. Alan Wang, NRR/DORL Mail Stop OWFN/8 B1 11555 Rockville Pike Rockville, MD 20852-2378 U. S. Nuclear Regulatory Commission ATTN: Mr. Nathaniel Ferrier, NRR/DORL Mail Stop OWFN/11 F1 11555 Rockville Pike Rockville, MD 20852-2378 NRC Senior Resident Inspector Grand Gulf Nuclear Station Port Gibson, MS 39150 GNRO-2013/00001 Response to Electronic Request For Additional Information Supporting Completion of the Safety Evaluation for the License Amendment Request for Revision of Technical Specification Allowable Value for Primary Containment and Dryweilisolation Instrumentation Function 3.c "RCIC Steam Supply Line Pressure

- Low."

The format for the Request for Additional Information (RAI) responses below is as follows. The RAI is listed in its entirety as received from the Nuclear Regulatory Commission (NRC). This is followed by the Grand Gulf Nuclear Station (GGNS) RAI response to the individual question.

A.

It is stated in clause 5.1 of Calculation JC*Q1 E31*N685-1, RCIC Turbine Isolation on Low Inlet Steam Pressure, that all uncertainties given in vendor data specifications are assumed to be 2 sigma unless otherwise specified. Provide detail information based on which this assumption has been made, including vendor provided documents or extracts from the documents to justify how the 95/95 confidence level stated in RG 1.105 is achieved.

Response

Rosemount transmitter accuracy specifications are 3 sigma values based on the attached Rosemount letter dated 4/4/00, GEXI 2000-00134 (see attachment 2).

Rosemount trip unit accuracy specifications are 3 sigma values based on attached Rosemount fax dated 9/29/94 (see attachment 3). Therefore, a 95/95 confidence level is ensured.

B.

It is stated in clause 3.2.10 of Calculation JS09, Revision 1, Grand Gulf Nuclear Station Instrument and Control Standard Methodology For The Generation Of Instrument Loop Uncertainty & Setpoint Calculations, that the drift values can be based on published vendor specifications or the values can be determined based on statistical analysis of as-found and as-left calibration data per ECHNE 00015 and EPRI TR-103335 Rev. 1. Provide documents and/or calculations on how the device drift values have been established to ensure 95/95 confidence level.

Response

The 30 month drift values utilized in JC-Q1 E31-N685-1 rev 1 were derived in JC-Q1111-09019 which determines the drift values for the subject instrumentation by statistical analysis of historical As Found / As Left data from calibration records.

The analysis is done in accordance with the Electric Power Research Institute's TR-1 03335R1, "Statistical Analysis of Instrument Calibration Data; Guidelines for Instrument Calibration Extension / Reduction Programs," dated October 1998.

Therefore, a 95/95 confidence level is ensured. A copy of JC-Q1111-09019 is attached (see attachment 4).

C. TSTF 493 includes procedural criteria regarding exceeded limits and channels that cannot be reset within ALT. The TSTF-493 procedural criteria should be addressed for each of the functions covered by the TSTF owner's group letter of April 23, 2012 (ML101160026), regardless of whether the channel is a LSSS or not. Provide documents or relevant extracts from the documents to address the plant procedures and/or the corrective action programs that will be followed when the channel trip setpoints, during the surveillance tests, indicate one or more of the followings:

1. The TS AV is exceeded
2. The as-found tolerance limit is exceeded
3. The instrument channel can not be reset within the as-left tolerance limit.

Response

A condition report would be generated for each of the three situations per section 6.8.2 (d) of 01-8-06-12. In the third situation the instrument channel would be declared inoperable per section 5.9 [21] (d) of EN-OP-104. Excerpts of both procedures are attached as requested (see attachments 5 and 6).

GNRO-2013/00001 Copy of GEX12000-00134

Rosemount Nuclear Instruments 4 April 2000

'1:

~Nucla.lnltnllnellts.lnc.

12001 TCCMOlOgy Drive Eden Plain., MN ~.. USA Tel '(612) 82803252 Fax 1 (1112) 82&-S280

(,e1.:1

}.o 0 lJ - CH' I 3 'f

,Jf£;:i/~

eelj"/!,t L,'=,I ~

(.))

Ref: Grand OulfNuclear Station message on INPO plant reports, subject Rosemount Instnunent Sctpoint Methodology, dated March 9, 2000

Dear Customer:

This letter is inteoded to eliminate any contusion that may have arisen as a result ofthe reference meuap from Orand Gulf. The messagewu coaeemed with statistical variation associated with published pm'onnance variables and bow the variation relates to the published specifications in Rosemount Nuclear InstrUJnents, Inc.(RNII) pressure traDsmitter models 1152, 11S3 Series 8, 1153 Series D, 11S4 and 11S4 Series H. Accordin. to our undcrswadin& the perfonnancc variables ofprimary concern are those discussed in OE Instrument Setpoint Methodology document NEDC 31336, namely I.

RcfctCftCC Accuracy 2.

AmbiC1lt Temperature Effect 3.

Ovelpte8IUrC Effect 4.

Static Pressure Bffects s.

Power Supply Effect It is RNU's understanding tbat GE and the NRC.haw accepted the methodology ofusing nnsmittertesting to insure specifications arc met as a basis for confirming specifications arc

+/-3a. The conclusions we draw reprding speciticadoDS beina :t3a are based on manufacturing testing and screenina, (mal assembly acceptaIlce testing. periodic (e.g., every 3 months) audit testins oftransmitter samples and limited statistical analysis. Please note that all performance specifications arebased on ~based ranges u.ndcr reference conditions. Einally, we wish to make clear that no inferences are made with respect to confidence levels associated with any specification.

1. Bef,regse Accaraev.

AU (100%) RNII transmittln, incloclinamodels 1152, 1153 Series B, 115'3 Series D, 1154 and 11.54 SeriesII, arc tested to verify ICCUrICY to +/-O.2S%ofspan II 00.4, 20%, 40%, 60%,

soe" and 100% otspan. Therefore, the reference accuracy published in our specifications is considered+/-30.

2.

Amblu. 1...."... Etred All (100%) amplifier boards are tested tor compliance with their temperature effect specificauoas prior to final assembly. All.....modules, with the exception ofmodel 11S4, are temperalUrC compensated to assure compUIIICe with their temperature effect specifications. All (100%) modell1S4, modeIllS4 Series H and modelllS3 gage and absolute pressure tI3nSmittets ale tested rollowlng final assembly to verifY compliance with specification. Additionally, a nmow oCaudit.. data performed on final assemblies of model1!52 and model 1153 uansmitters not tasted following rmal assembly indicate

conformance to specification. Therefore, the ambient temperature effect published in our specifications is coDSidaed +/-3c:r.

3.

Oyerpr!llV! Med Testinl oftbis variable is done at the module BIlle. All (lOOOAi) ranse 3 through 8 sensor modules are tested for compliance to specifications. We do not test range 9or 10 modules for overpreaure for safety reasons. However. design similarity permits us to conclude that statemeDti made for ranges 3tbrouab 8 would alIo apply co ruses 9 and 10. Therefore, the overpressure effect published in our specifications is considered +/-3a.

4.

Static Prwpre Eft'aets All (100%) differential pressure sensor modul. are tesled fOf compliance with static pressure zero errors. Additionally, Models 1153 sad 1154 Ranges 3, 6,7 and 8 are lOO'.4 tested after final usombly Cor added assurance orspecificldon compliance. Audit testing performed on ranges 4 and S have sbown compliance to the specification. Therefore, static pressure effectS published in our specificarions arc considend +/-30'.

S.

PowerSD.' Elect Testing Cor CODfonnance to this specification is perfmmed on all transmitters undergoing sample (audit) taliDg. This variable has historically exhibited extremely small performance carolS aDd small standard deviation (esseatial1y a mean mof ofzero with astandard deviation typically leas thaD 10% ofthe specification). All transmitters tested were found in compliance with the specification. Therefore, power supply effect published in our specifications is considered+/-3a.

Should you have any fbrther questions, please con1art Jerry Edwards at (612) 828-3951.

Sincerely, lilly L. Bdwards Manager, Sales. MarbtiDa and Contracts R.oscmount Nuclear1DstnJmena, Inc.

7671 DIll U0CFR21~Aprl2OOCHt8IisbI....

TOT~ P.92 GNRO-2013/00001 Rosemount Fax Dated 9/29/94

. I

~

~~"" FISHER-RdSEMOUNT DATE:

~/~1/~i COMPANY:

G*~~

C~(..r ATTENTION: -rr ~

61bf~-r FAX NUMBER:

f,ol- "31-2/ y(

SUBJECT:

tlo 5,..?c-c..S cc:

Rosemount HuclearInSbUhle,nts,Inc.

12001 Technology Drive Eden Prairie.MN 55344-3695 USA PAGE(S) INCLUDING LEAD SHEET:

S-FAX NUMBER:

(612) 828-8280

~..

SENDER:

Ian Baldry Jane Dougherty Sandstrom PHONE NUMBER:

'(612) 828-8250 A--,-rA~,-,.I~

i.s

$P<!;~C ~

1# 'Crt-

-rt.f£ rp(!~T)V<...f ~~

.s~~

D)I.,.,J J\\.c.-G4ol,~

7 I D C'.A-L. 1/.5J£.4 7'l'J'j!.,J.

,~0 VT+S J'($h( ~l. ~

-r' (~

yPOf.-J' f2..e!M?7 131 L I7'f c~ ;JIl-..,4.-7?:J~ A-c. UU;1Lt+-i:Af t

~-t>Ql.)r

~SSMl~L"1 A-C.(.A.ULA.el1 l-..,)<JtJI.-l)

,.vf~

&r U"klrJ 4-5

~~

UJ4J I T

/..5 Tt-GST'fD r;;o,.!..

71k1J l.""

~c-T$

P/Z.Lo~

,I

\\'

(

/J_Jlro...~I~-

AJtn.U~

$f~' -ro

-ro c..~)fJ v~..,-

Ck<,A,') f,krotl-.j.

r'-C;"111J,*

~.

\\

'l

()F-Sf...,.,J u~e: ~

~'--vt./Tl!IL.

~16,zAJrC1) s/;',...J s,Jc.t I

~)~

.5f'tS'< f ~

1'II~.jIfl.s fjf' Ms <)W.ITE IJ.. In; /ZA.ml!'C- ~

7~CC'N<<"

of spt.,J (e_,.

t. 00'> ~A j,,,, ",A

't!>..,!J.Z ¥--).

-~'...~---_.

"~'-

S*.'T "d 0°

.. -.~.

d':'3lJnt,J 'It*,lnCIl-13S0d.1**Jd82': t70 t76,iA 62 d3S GNRO-2013/00001 Copy of JC-Q1111-09019

DANO-1 o ANO-2 l8J GGNS o IP-2 o IP-3 DpLP DJAF OPNPS ORBS DVY DW3 o NP-GGNS-3 o NP-RBS-3 CALCULATION (1) EC #

39554 (2)

Page 1 of...1§!L COVER PAGE (3) Design Basis Calc. ~ YES ONO (4)

~ CALCULATION DEC Markup (5) Calculation No: JC-Q1111-09019 (6) Revision: 000 (7)

Title:

Drift Calculation for Rosemount Range Codes 5-8 Gage Pressure

\\8) Editorial DYES

~ NO Transmitters (9) System(s): 821, C61, E12, E21, E22, (10) Review Org (Department): NPE (I&C Design)

E31, E32 and E51 (11) Safety Class:

(12) Component/Equipment/Structure TypelNumber:

[81 Safety / Quality Related See Table 1.2-1 o Augmented Quality Program o Non-Safety Related (13) Document Type: J05.02 (14) Keywords (DescriptionITopical Codes):

Drift REVIEWS (15) Name/Signature/Date (16) Name/Signature/Date (17) Name/Signature/Date J-.£t r/I/I tI see AS for EOI acceptance R.J. Hannigan wfjl!---

and Supervisor approval Aaron Castor I f'/'ljJ) signatures Responsible Engineer I:8J Design Verifier Supervisor/Approval o Reviewer cg) Comments Attached o Comments Attached

DRIFT ANALYSIS ENGINEERING DEPARTMENT GRAND GULF NUCLEAR STATION JC-Q1111-09019 Revision 000 Page 2 of 27 CALCULATION CALCULATION NO:

JC-Q1111-09019 REFERENCE SHEET REVISION:

000 I.

EC Markups Incorporated None II.

Relationships:

Sht Rev Input Output Impact Tracking Doc Doc YIN No.

1.

CR-GGN-1997-01238 0

~

0 N

2.

CR-GGN-2002-00723 0

~

0 N

3.

CR-GGN-2004-01015 0

~

0 N

4.

CR-GGN-2005-00119 0

~

0 N

5.

CR-GGN-2008-02476 0

~

0 N

6.

CR-GGN-2008-02479 0

~

0 N

7.

CR-GGN-2008-03029 0

~

0 N

8.

CR-GGN-2008-03143 0

~

0 N

9.

ECH-NE-08-00015 001

~

0 N

10. JC-Q1 E12-N655-1 0

001 0

~

Y EC39554

11. JC-Q1E12-N658-1 0

002 0

~

Y EC39554

12. JC-Q1 E21-N650-1 0

000 0

~

Y EC39554

13. JC-Q1 E21-N652-1 0

000 0

~

Y EC39554

14. JC-Q1E22-N654-1 0

003 0

~

Y EC39554

15. JC-Q1 E31-N685-1 0,

000 0

~

Y EC39554

16. JC-Q1 E51-N635-1 0

001 0

~

Y EC39554

17. JC-Q1 E51-N655-1 0

000 0

~

Y EC39554

18. JC-Q1R21-90025 0

001 0

~

Y EC39554

19. MAI00251345 0

~

0 N

20.

MAI00251443 0

~

0 N

21.

MAI00251444 0

~

0 N

22.

MAI00251671 0

~

0 N

23.

MAI00251812 0

~

0 N

24. MAI00251817 0

~

0 N

25.

MAI00251818 0

~

0 N

26.

MAI00252225 0

~

0 N

27.

MAI00252535 0

~

0 N

28.

MAI00252672 0

~

0 N

29.

MAI00253027 0

~

0 N

30.

MAI00254184 0

~

0 N

31.

MAI00254185 0

~

0 N

32.

MAI00254186 0

~

0 N

33.

MAI00254187 0

~

0 N

34.

MAI00254804 0

~

0 N

DRIFT ANALYSIS ENGINEERING DEPARTMENT GRAND GULF NUCLEAR STATION JC-Q1111-09019 Revision 000 Page 3 of 27 CALCULATION CALCULATION NO:

JC-Q1111-09019 REFERENCE SHEET REVISION:

000 II.

Relationships (cont'd):

Sht Rev Input Output Impact Tracking Doc Doc YIN No.

35. MAI00255022 0

[g]

0 N

36. MAI00255599 0

[g]

0 N

37. MAI00256836 0

[g]

0 N

38. MAI00257175 0

[g]

0 N

39. MAI00257176 0

[g]

0 N

40. MAI00257205 0

[g]

0 N

41. MAI00257226 0

[g]

0 N

42. MAI00259025 0

[g]

0 N

43. MAI00259338 0

[g]

0 N

44. MAI00259354 0

[g]

0 N

45. MAI00259878 0

[g]

0 N

46. MAI00260093 0

[g]

0 N

47. MAr00260094 0

[g]

0 N

48. MAI00260095 0

[g]

0 N

49. MAI00260096 0

[g]

0 N

50. MAI00261569 0

[g]

0 N

51. MAI00263073 0

[g]

0 N

52. MAI00280934 0

[g]

0 N

53. MAI00282111 0

[g]

0 N

54. MAI00282425 0

[g]

0 N

55. MAI00282470 0

[g]

0 N

56. MAI00282538 0

[g]

0 N

57. MAI00283045 0

[g]

0 N

58. MAI00283189 0

[g]

0 N

59. MAI00283190 0

[g]

0 N

60. MAI00283191 0

[g]

0 N

61. MAI00283854 0

[g]

0 N

62. MAlOO285559 0

[g]

0 N

63. MAI00285951 0

[g]

0 N

64. MAI00285952 0

[g]

0 N

65. MAI00285953 0

[g]

0 N

66. MAI00285955 0

[g]

0 N

67.

MAI00286187 0

[g]

0 N

68. MAI00286827 0

[g]

0 N

69. MAI00286828 0

[g]

0 N

70. MAI00286973 0

[g]

0 N

71. MAI00286974 0

~

0 N

72. MAI00286977 0

[g]

0 N

73. MAI00286978 0

[g]

0 N

74. MAI00286979 0

[g]

0 N

75. MAI00286980 0

[g]

0 N

76. MAI00289265 0

[g]

0 N

DRIFT ANALYSIS ENGINEERING DEPARTMENT GRAND GULF NUCLEAR STATION JC*Q1111*09019 Revision 000 Page 4 of 27 CALCULATION CALCULATION NO:

JC-Q1111-09019 REFERENCE SHEET REVISION:

000 II.

Relationships (cont'd):

Sht Rev Input Output Impact Tracking Doc Doc YIN No.

77. MAI00290871 0

[&J D

N

78. MAI00291404 0

[&J D

N

79. MAI00291832 0

[&J D

N

80. MAI00291849 0

[&J D

N

81. MAI00291871 0

[&J D

N

82. MAI00291880 0

[&J D

N

83. MAI00291903 0

[&J D

N

84. MAI00303978 0

[&J D

N

85. MAI00304507 0

[&J D

N

86. MAI00304508 0

[&J D

N

87. MAI00306358 0

[&J D

N

88. MAI00306360 0

[&J D

N

89. MA10030636'1 0

[&J D

N

90. MAI00306364 0

[&J D

N

91. MAI00306367 0

[&J D

N

92. MAI00306368 0

[&J D

N

93. MAI00306490 0

[&J D

N

94. MAI00306491 0

[&J D

N

95. MAI00307027 0

[&J D

N

96. MAI00307030 0

[&J D

N

97. MAI00308443 0

[&J D

N

98. MAI00308444 0

[&J D

N

99. MAI00308500 0

[&J D

N 100. MAI00308501 0

[&J D

N 101. MAI00308534 0

[&J D

N 102. MAI00308657 0

[&J D

N 103. MAI00308658 0

[&J D

N 104. MAI0031 0079 0

[&J D

N 105. MAI0031 0080 0

[&J D

N 106. MAI0031 0352 0

[&J D

N 107. MAI0031 0355 0

[&J D

N 108. MAI00311 078 0

[&J D

N 109. MAI00311079 0

[&J D

N 110. MAI00311080 0

[&J D

N 111. MAI00311 085 0

[&J D

N 112. MAI00311305 0

[&J D

N 113. MAI00313760 0

[&J 0

N 114. MAI00313761 0

[&J 0

N 115. MAI00313762 0

[&J 0

N 116. MAI00320062 0

1RI D

N 117. MAI00320063 0

[&J D

N 118. MAI00321196 0

[&J 0

N

DRIFT ANALYSIS ENGINEERING DEPARTMENT GRAND GULF NUCLEAR STATION JC*Q1111*09019 Revision 000 Page 5 of 27 CALCULATION CALCULATION NO:

JC-Q1111-09019 REFERENCE SHEET REVISION:

000 II.

Relationships (cont'd):

Sht Rev Input Output Impact Tracking Doc Doc YIN No.

119. MAI00321197 0

I:&l 0

N 120. MAI00324375 0

I:&l 0

N 121.WOO0185520 0

I:&l 0

N 122.WOO0185521 0

I:&l 0

N 123.WOO0185522 0

I:&l 0

N 124.WOO0185523 0

I:&l 0

N 125.WOO0185748 0

I:&l 0

N 126.WOOD185749 0

I:&l 0

N 127.WOO0185750 0

I:&l 0

N 128.WOO0186567 0

I:&l 0

N 129.WOO0186568 0

I:&l 0

N 130.WOO0189114 0

I:&l 0

N 131.WOO0189115 0

I:&l 0

N 132.WOO0189116 0

I:&l 0

N 133.WOO0189117 0

I:&l 0

N 134.WOO0189118 0

I:&l 0

N 135.WOO0189119 0

I:&l 0

N 136.WOO0189120 0

I:&l 0

N 137.WOO0189190 0

I:&l 0

N 138.WOO0189191 0

I:&l 0

N 139.WOO0189192 0

I:&l 0

N 140. WOO0189193 0

I:&l 0

N 141.WOOD190241 0

I:&l 0

N 142.WOO0190242 0

I:&l 0

N 143.WOO0190249 0

I:&l 0

N 144. WOO0190250 0

I:&l 0

N 145.WOO0190251 0

I:&l 0

N 146.WOO0191097 0

I:&l 0

N 147. WOO0191098 0

I:&l 0

N 148. WOO0191549 0

I:&l 0

N 149.WOO0191550 0

I:&l 0

N 150.WOOD192923 0

I:&l 0

N 151.WOO0195637 0

I:&l 0

N 152. WOOD195638 0

I:&l 0

N 153.WOO0197357 0

I:&l 0

N 154.WOO0197358 0

I:&l 0

N 155. WOO0199035 0

00 0

N 156.WOO0200674 0

00 0

N 157. WOO0200675 0

00 0

N 158.WOO0200676 0

I:&l 0

N 159.WOO0200677 0

I:&l 0

N 160.WOO0202633 0

00 0

N

DRIFT ANALYSIS ENGINEERING DEPARTMENT GRAND GULF NUCLEAR STATION JC*Q1111*09019 Revision 000 Page 6 of 27 CALCULATION CALCULATION NO:

JC-Q1111-09019 REFERENCE SHEET REVISION:

000 II.

Relationships (cont'd):

Sht Rev Input Output Impact Tracking Doc Doc YIN No.

161.WOO0202640 0

1:&1 0

N 162.WOO0202645 0

1:&1 0

N 163.WOO0202660 0

1:&1 0

N 164.WOO0204476 0

1:&1 0

N 165.WOO0206482 0

1:&1 0

N 166.WOO0206483 0

1:&1 0

N 167.WOO0206484 0

1:&1 0

N 168.WOO0206485 0

1:&1 0

N 169.WOO0215651 0

1:&1 0

N 170.WOO0215653 0

1:&1 0

N 171.WOO0216438 0

1:&1 0

N 172.WOO0218729 0

1:&1 0

N 173.WOO0218730 0

1:&1 0

N 174.WOO0218731 0

1:&1 0

N 175.WO-00058576 0

1:&1 0

N 176.WO-00058935 0

1:&1 0

N 177.WO-OO139131 0

1:&1 0

N 178.WO-00142496 0

1:&1 0

N 179.WO-OO194277 0

1:&1 0

N 180.WO-50306713 0

1:&1 0

N 181.WO-50306714 0

1:&1 0

N 182.WO-50306715 0

1:&1 0

N 183.WO-50306716 0

1:&1 0

N 184.WO-50306717 0

1:&1 0

N 185.WO-50306723 0

1:&1 0

N 186.WO-50306776 0

1:&1 0

N 187.WO-50306777 0

1:&1 0

N 188.WO-50306778 0

1:&1 0

N 189.WO-50306939 0

1:&1 0

N 190.WO-50306940 0

1:&1 0

N 191.WO-50308254 0

1:&1 0

N 192.WO-50308255 0

1:&1 0

N 193.WO-50308277 0

1:&1 0

N 194.WO-50308278 0

1:&1 0

N 195.WO-50308354 0

1:&1 0

N 196.WO-50308355 0

1:&1 0

N 197.WO-50308541 0

IX) 0 N

198.WO-50308542 0

IX) 0 N

199.WO-50309607 0

IX) 0 N

200. WO-50309608 0

IX) 0 N

201. WO-50309652 0

IX) 0 N

202. WO-50309653 0

IX) 0 N

DRIFT ANALYSIS ENGINEERING DEPARTMENT GRAND GULF NUCLEAR STATION JC-Q1111-09019 Revision 000 Page 70f27 CALCULATION CALCULATION NO:

JC-Q1111-09019 REFERENCE SHEET REVISION:

000 II.

Relationships (cont'd):

Sht Rev Input Output Impact Tracking Doc Doc YIN No.

203. WO-50309680 0

[RJ 0

N 204. WO-50309721 0

[RJ 0

N 205. WO-50314733 0

[RJ 0

N 206. WO-50314734 0

[RJ 0

N 207. WO-50314735 0

[RJ 0

N 208. WO-50314736 0

[RJ 0

N 209. WO-50317885 0

[RJ 0

N 210. WO-50317886 0

[RJ 0

N 211. WO-50317887 0

[RJ 0

N 212. WO-50317888 0

[RJ 0

N 213. WO-50317889 0

[RJ 0

N 214. WO-50317890 0

[RJ 0

N 215. WO-50322411 0

[RJ 0

N 216. WO-50322460 0

[RJ 0

N 217. WO-50322464 0

[RJ 0

N 218. WO-50322496 0

[RJ 0

N 219. WO-50322498 0

[RJ 0

N 220. WO-50322504 0

[RJ 0

N 221. WO-50322511 0

[RJ 0

N 222. WO-50322582 0

[RJ 0

N 223. WO-50322593 0

[RJ 0

N 224. WO-50322600 0

[RJ 0

N 225. WO-50322624 0

[RJ 0

N 226. WO-50327801 0

[RJ 0

N 227. WO-50327828 0

[RJ 0

N 228. WO-50327829 0

[RJ 0

N 229. WO-50327830 0

[RJ 0

N 230. WO-50327831 0

[RJ 0

N 231. WO-50327832 0

[RJ 0

N 232. WO-50327875 0

[RJ 0

N 233. WO-50327876 0

[RJ 0

N 234. WO-50333440 0

[RJ 0

N 235. WO-50336454 0

[RJ 0

N 236. WO-50337140 0

[RJ 0

N 237. WO-50337141 0

[RJ 0

N 238. WO-50337142 0

[RJ 0

N 239. WO-50337143 0

~

0 N

240. WO-50337170 0

[RJ 0

N 241. WO-50337171 0

[RJ 0

N 242. WO-50613145 0

[RJ 0

N 243. WO-50686013 0

[RJ 0

N 244. WO-50686067 0

[RJ 0

N

DRIFT ANALYSIS ENGINEERING DEPARTMENT GRAND GULF NUCLEAR STATION JC*Q1111*09019 Revision 000 Page 8 of 27 CALCULATION CALCULATION NO:

JC-Q1111-09019 REFERENCE SHEET REVISION:

000 II.

Relationships (cont'd):

Sht Rev Input Output Impact Tracking Doc Doc YIN No.

245. WO-50686652 0

[&J 0

N 246. WO-50970134 0

[&J 0

N 247. WO-50970135 0

[&J 0

N 248. WO-50973882 0

[&J 0

N 249. WO-50973901 0

[&J 0

N 250. WO-50973930 0

[&J 0

N 251. WO-50975745 0

[&J 0

N 252. WO-50975772 0

[&J 0

N 253. WO-50977528 0

[&J 0

N 254. WO-50977637 0

[&J 0

N 255. WO-50978711 0

[&J 0

N 256. WO-50980006 0

[&J 0

N 257. WO-50980051 0

[&J 0

N 258. WO-50980052 0

[&J 0

N 259. WO-50980053 0

[&J 0

N 260. WO-50981198 0

[&J 0

N 261. WO-50982466 0

[&J 0

N 262. WO-50982512 0

[&J 0

N 263. WO-50983525 0

[&J 0

N 264. WO-50983827 0

[&J 0

N 265. WO-50983828 0

[&J 0

N 266. WO-50983832 0

[&J 0

N 267. WO-50983948 0

[&J 0

N 268. WO-50984722 0

[&J 0

N 269. WO-50984723 0

[&J 0

N 270. WO-50985322 0

[&J 0

N 271. WO-50985390 0

[&J 0

N 272. WO-50985435 0

[&J 0

N 273. WO-50987762 0

[&J 0

N 274. WO-50989719 0

[&J 0

N 275. WO-50990333 0

[&J 0

N 276. WO-50991321 0

[&J 0

N 277. WO-50991986 0

[&J 0

N 278. WO-50991987 0

[&J 0

N 279. WO-50992037 0

[&J 0

N 280. WO-50994330 0

[&J 0

N 281.WO-50994331 0

[8]

0 N

282. WO-50994396 0

[8]

0 N

283. WO-50996151 0

[&J 0

N 284. WO-50998956 0

[&J 0

N 285. WO-50999388 0

[&J 0

N 286. WO-51 006586 0

[&J 0

N

DRIFT ANALYSIS ENGINEERING DEPARTMENT GRAND GULF NUCLEAR STATION JC-Q1111-09019 Revision 000 Page 9 of 27 CALCULATION CALCULATION NO:

JC-Q1111-09019 REFERENCE SHEET REVISION:

000 II.

Relationships (cont'd):

Sht Rev Input Output Impact Tracking Doc Doc YIN No.

287. WO-51 008726 0

[8]

0 N

288. WO-51 008790 0

[8]

0 N

289. WO-51 009240 0

[8]

0 N

290.WO-51 015049 0

[8]

0 N

291. WO-51016899 0

[8]

0 N

292. WO-51019104 0

[8]

0 N

293. WO-51 020092 0

[8]

0 N

294. WO-51021313 0

[8]

0 N

295. WO-51021969 0

[8]

0 N

296. WO-51 022008 0

[8]

0 N

297. WO-51 023736 0

[8]

0 N

298. WO-51 027321 0

[8]

0 N

299.WO-51027322 0

[8]

0 N

300. WO-51 027435 0

[8]

0 N

301. WO-51 028455 0

[8]

0 N

302. WO-51 029632 0

[8]

0 N

303. WO-51 029633 0

[8]

0 N

304. WO-51 030183 0

[8]

0 N

305. WO-51 030403 0

[8]

0 N

306. WO-51 030404 0

[8]

0 N

307. WO-51 030789 0

[8]

0 N

308. WO-51 030839 0

[8]

0 N

309. WO-51031314 0

[8]

0 N

310. WO-51 032764 0

[8]

0 N

311. WO-51 032823 0

[8]

0 N

312. WO-51 032926 0

[8]

0 N

313. WO-51 033553 0

[8]

0 N

314. WO-51 033602 0

[8]

0 N

315. WO-51 033658 0

[8]

0 N

316. WO-51 035351 0

[8]

0 N

317. WO-51 036728 0

[8]

0 N

318. WO-51 038969 0

[8]

0 N

319. WO-51 040729 0

[8]

0 N

320. WO-51 041801 0

[8]

0 N

321. WO-51 041875 0

[8]

0 N

322. WO-51 041876 0

[8]

0 N

323. WO-51 041877 0

[Rl 0

N 324. WO-51 043041 0

[Rl 0

N 325. WO-51 045238 0

[Rl 0

N 326. WO-51 045239 0

[8]

0 N

327. WO-51 046288 0

[Rl 0

N 328. WO-51 046420 0

[8]

0 N

DRIFT ANALYSIS ENGINEERING DEPARTMENT GRAND GULF NUCLEAR STATION JC-Q1111-09019 Revision 000 Page 10 of 27 CALCULATION CALCULATION NO:

JC-Q1111-09019 REFERENCE SHEET REVISION:

000 II.

Relationships (cont'd):

Sht Rev Input Output Impact Tracking Doc Doc YIN No.

329. WO-51 046894 0

[BJ 0

N 330. WO-51 047621 0

[BJ 0

N 331. WO-51 054701 0

[BJ 0

N 332. WO-51 086575 0

[BJ 0

N 333. WO-51 086979 0

[BJ 0

N 334. WO-51 088461 0

[BJ 0

N 335. WO-51 098925 0

[BJ 0

N 336. WO-51190342 0

[BJ 0

N 337. WO-51191543 0

[BJ 0

N 338. WO-51192024 0

[BJ 0

N 339. WO-51192025 0

[BJ 0

N 340. WO-51201705 0

[BJ 0

N 341. WO-51204851 0

[BJ 0

N 342. WO-5121 0198 0

[BJ 0

N 343. WO-51511083 0

[BJ 0

N 344. WO-515111 09 0

[BJ 0

N 345. WO-51513154 0

[BJ 0

N 346. WO-51513252 0

[BJ 0

N 347. WO-51513270 0

[BJ 0

N 348. WO-51513864 0

[BJ 0

N 349. WO-51514543 0

[BJ 0

N 350. WO-51514764 0

[BJ 0

N 351. WO-51514861 0

[BJ 0

N 352. WO-51515103 0

[BJ 0

N 353. WO-51515757 0

[BJ 0

N 354. WO-51515758 0

[BJ 0

N 355. WO-51521817 0

[BJ 0

N 356. WO-5152192.1 0

[BJ 0

N 357. WO-51521985 0

[BJ 0

N 358. WO-51523256 0

[BJ 0

N 359. WO-51523341 0

[BJ 0

N 360. WO-51547287 0

[BJ 0

N 361. WO-51547450 0

[BJ 0

N 362. WO-51548265 0

[BJ 0

N 363. WO-51557498 0

[BJ 0

N 364. WO-51561105 0

[BJ 0

N 365. WO-51562282 0

[BJ 0

N 366. WO-51562283 0

[BJ 0

N 367. WO-51562284 0

[BJ 0

N 368. WO-51562762 0

[BJ 0

N 369. WO-51568242 0

[BJ 0

N 370. WO-51568243 0

[BJ 0

N

DRIFT ANALYSIS ENGINEERING DEPARTMENT GRAND GULF NUCLEAR STATION JC*Q1111*09019 Revision 000 Page 11 of 27 CALCULATION CALCULATION NO:

JC-Q1111-09019 REFERENCE SHEET REVISION:

000 II.

Relationships (cont'd):

Sht Rev Input Output Impact Tracking Doc Doc YIN No.

371. WO-51568376 0

[&l 0

N 372. WO-51568482 0

[&l 0

N 373. WO-51569255 0

[&l 0

N 374.WO-51656659 0

[&l 0

N 375. WO-51657859 0

[&l 0

N 376. WO-51673215 0

[&l 0

N 377. WO-51676562 0

[&l 0

N 378. WO-51679875 0

[&l 0

N 379. WO-51680448 0

[&l 0

N 380. WO-51685859 0

[&l 0

N 381. WO-51687384 0

[&l 0

N 382. WO-51689653 0

[&l 0

N 383. WO-51693888 0

[&l 0

N 384. WO-51794367 0

[&l 0

N 385. WO-51794963 0

[&l 0

N 386. WO-51801602 0

[&l 0

N 387. WO-51801741 0

[&l 0

N 388. WO-52022052 0

[&l 0

N 389. WO-52022295 0

[&l 0

N 390. WO-52022466 0

[&l 0

N 391.WO-52022469 0

[&l 0

N 392. WO-52022470 0

[&l 0

N 393. WO-52022471 0

[&l 0

N 394. WO-52022665 0

[&l 0

N 395. WO-52022666 0

[&l 0

N 396. WO-52023286 0

[&l 0

N 397. WO-52023591 0

[&l 0

N 398. WO-52035001 0

[&l 0

N 399. WO-52035006 0

[&l 0

N 400. WO-52040111 0

[&l 0

N 401.WO-52186459 0

[&l 0

N 402. WO-52186460 0

[&l 0

N 403. WO-52186461 0

[&l 0

N 404. WO-52186614 0

[&l 0

N 405. WO-52186615 0

[&l 0

N 406. WO-52190723 0

[&l 0

N 407. WO-52191222 0

[&l 0

N 408. WO-52192000 0

[&l 0

N 409. WO-52192443 0

[&l 0

N 410. WO-52192733 0

[&l 0

N 411.WO-52192734 0

[&l 0

N 412. WO-52192742 0

[&l 0

N

DRIFT ANALYSIS ENGINEERING DEPARTMENT GRAND GULF NUCLEAR STATION JC*Q1111*09019 Revision 000 Page 12 of 27 CALCULATION CALCULATION NO:

JC-Q1111-09019 REFERENCE SHEET REVISION:

000 II.

Relationships (cont'd):

Sht Rev Input Output Impact Tracking Doc Doc YIN No.

413. WO-52193379 0

[RJ 0

N 414. WO-52193547 0

[RJ 0

N 415. WO-52194679 0

[RJ 0

N 416. WO-52194680 0

[RJ 0

N 417. WO-52195006 0

[RJ 0

N 418. WO-52207300 0

[RJ 0

N 419. WO-52221326 0

[RJ 0

N 420. WO-52221327 0

[RJ 0

N 421. WO-52231861 0

[RJ 0

N 422. WO-52239885 0

[RJ 0

N 423. WO-52248778 0

[RJ 0

N 424. WO-52257429 0

[RJ 0

N III.

CROSS

REFERENCES:

1. American National Standard N15.15-1974, Assessment of the Assumption of Normality (Employing Individual Observed Values) 2.

ANSI/ISA-S67.04-Part 1-2000, Setpoints for Nuclear Safety Related Instrumentation 3.

DOE Research and Development Report No.

WAPD-TM-1292, Statistics for Nuclear Engineers and Scientists Part 1: Basic Statistical Inference, February 1981 4.

EPRI TR-1 03335R1, Statistical Analysis of Instrument Calibration Data; Guidelines for Instrument Calibration Extension / Reduction Programs, October 1998 5.

ISA-RP67.04-Part 11-2000, Methodologies for the Determination of Setpoints for Nuclear Safety-Related Instrumentation, Second Printing, June 12, 1995 6.

NRC Generic Letter 91-04, Changes in Technical Specification Surveillance Requirements to Accommodate a 24 Month Fuel Cycle, April 2, 1991 IV.

SOFTWARE USED:

Title:

N/A Version/Release:

Disk/CD No.

V.

DISK/CDS INCLUDED:

Title:

N/A Version/Release Disk/CD No.

VI.

OTHER CHANGES:

None

DRIFT ANALYSIS ENGINEERING DEPARTMENT GRAND GULF NUCLEAR STATION JC*Q1111*09019 Revision 000 Page 13 of 27 000 Initial issue.

DRIFT ANALYSIS ENGINEERING DEPARTMENT GRAND GULF NUCLEAR STATION 1

TABLE OF CONTENTS JC*Q1111*09019 Revision 000 Page 14 of 27 1

Purpose 15 2

Conclusions 19 3

Design Inputs 19 4

References 19 5

Assumptions 20 6

Method of Analysis 20 7

Analysis 22 8

Attachments 27 - Drift Analysis Supporting Information (Excel Spreadsheet) - 134 pages - DVR Forms with Comments - 7 pages

DRIFT ANALYSIS ENGINEERING DEPARTMENT GRAND GULF NUCLEAR STATION 1

Purpose JC*Q1111*09019 Revision 000 Page 15 of 27 1.1 The purpose of this analysis is to establish more realistic drift values and characteristics to be used by instrument uncertainty calculations for determination of setpoints and allowable values for the subject instrumentation. The drift values are determined by historical As Found / As Left data analysis.

1.2 Specifically, this analysis addresses Rosemount Range Codes 5-8 Gage Pressure Transmitters with tag numbers as shown in Table 1.2-1 below. Also shown in the table are the calibration procedure numbers, device functions, and applicable Technical Specification (TS) and Technical Requirements Manual (TRM) sections. The results of this analysis can be conservatively applied to any Rosemount Range Codes 5-8 Gage Pressure Transmitter used at Grand Gulf Nuclear Station that meets the criteria listed in Section 3.5.3 of Reference 4.1.3, "Considerations When Combining Components Into a Single Group".

TABLE 1.2-1 COMPONENT LIST A

1<

"AGNO.

  • 'NCTION TSITRMSECTION

...~.

Emergency Core Cooling Systems (ECCS) and Reactor Core Isolation Cooling (RCIC)

System 06-IC-1 B21-R-0010-01 1B21N201A SR TR 3.5.1.8 06-IC-1 B21-R-0010-02 1B21N201B ECCS-Alarm and Monitoring Instrumentation Accumulator Low Pressure Alarm Remote Shutdown System Instrumentation SR 3.3.3.2.3 06-IC-1 C61-R-0006-01 1C61N102 Function Condensate Storage Tank Level TR 3.3.3.2-1.A.8 Reactor Coolant System Instrumentation RCS Interface Valves, Pressure Monitors-Alarm Setpoints RHR System Valves SR TR 3.4.6.2 E12-F041A TO E12-F042A Function TR 3.4.6-3.4 Emergency Core Cooling Systems (ECCS) 06-IC-1 E12-R-0001-01 1E12N053A and Reactor Core Isolation Cooling (RCIC)

System ECCS-Alarm and Monitoring Instrumentation SR TR 3.5.1.6 LPCI Subsystems High Pressure Alarm Function TR 3.5.1.6.b Setpoint SR TR 3.5.1.9 LPCI A and B Low Pressure Alarm Function TR 3.5.1.9.a

DRIFT ANALYSIS ENGINEERING DEPARTMENT GRAND GULF NUCLEAR STATION JC*Q1111*09019 Revision 000 Page 16 of 27 TSlTRMSECTION PROCEDURE-ATT.

INunUN Reactor Coolant System Instrumentation RCS Interface Valves, Pressure Monitors-Alarm Setpoints SR TR 3.4.6.2, Function RHR System Valves TR 3.4.6-3.5 E12-F041B TO E12-F042B Emergency Core Cooling Systems (ECCS) 06-IC-1 E12-R-0001-02 1E12N053B and Reactor Core Isolation Cooling (RCIC)

System ECCS-Alarm and Monitoring Instrumentation SR TR 3.5.1.6, Function TR 3.5.1.6.b LPCI Subsystems High Pressure Alarm Setpoint SR TR 3.5.1.9, Function TR 3.5.1.9.a LPCI A and B Low Pressure Alarm Reactor Coolant System Instrumentation RCS Interface Valves, Pressure Monitors-Alarm Setpoints SR TR 3.4.6.2 RHR System Valves Function TR 3.4.6-3.6 E12-F041C TO E12-F042C Emergency Core Cooling Systems (ECCS) 06-IC-1 E12-R-Q001-03 1E12N053C and Reactor Core Isolation Cooling (RCIC)

System ECCS-Alarm and Monitoring Instrumentation SR TR 3.5.1.6 Function TR 3.5.1.6.b LPCI Subsystems High Pressure Alarm Setpoint SR TR 3.5.1.9 Function TR 3.5.1.9.a LPCI A and B Low Pressure Alarm Emergency Core Cooling Systems (ECCS)

Instrumentation 06-IC-1 E12-R-2002-04 1E12N055A ECCS-Alarm and Monitoring SR 3.3.5.1.5 06-IC-1 E12-R-2002-01 1E12N056A Instrumentation Function 3.3.5.1-1.4.1 LPCI Pump A Discharge Pressure - High Emergency Core Cooling Systems (ECCS) 06-IC-1 E12-R-2002-05 1E12N055B Instrumentation 06-IC-1 E12-R-2002-06 1E12N055C ECCS-Alarm and Monitoring SR 3.3.5.1.5 06-IC-1 E12-R-2002-02 1E12N056B Instrumentation Function 3.3.5.1-1.5.e 06-IC-1 E12-R-2002-03 1E12N056C LPCI Pumps B & C Discharge Pressure - High Reactor Coolant System Instrumentation RCS Interface Valves, Pressure Monitors-SR TR 3.4.6.2 Alarm Setpoints 06-IC-1 E12-R-1 011-01 1E12N057 Function TR 3.4.6-3.2 RHR System Valves SR TR 3.4.6.2 E12-F008 TO E12-F006A, Function TR 3.4.6-3.3 E12-F008 TO E12-F006B

DRIFT ANALYSIS ENGINEERING DEPARTMENT GRAND GULF NUCLEAR STATION JC*Q1111*09019 Revision 000 Page 17 of 27 PROCEDURE..Arr=

FUN\\;IIUN.

TSITRM< SECTION Reactor Coolant System Instrumentation RCS Interface Valves, Pressure Monitors-06-IC-1 E12-R-101 0-01 1E12N058A Interlock Setpoints SR TR 3.4.6.2 Function TR 3.4.6-2.2 RHR System Valves E12-F041A TO E12-F042A Reactor Coolant System Instrumentation RCS Interface Valves, Pressure Monitors-06-IC-1 E12-R-1 01 0-02 1E12N058B Interlock Setpoints SR TR 3.4.6.2 Function TR 3.4.6-2.3 RHR System Valves E12-F041B TO E12-F042B Reactor Coolant System Instrumentation RCS Interface Valves, Pressure Monitors-06-IC-1 E12-R-1 01 0-03 1E12N058C Interlock Setpoints SR TR 3.4.6.2 Function TR 3.4.6-2.4 RHR System Valves E12-F041C TO E12-F042C Reactor Coolant System Instrumentation RCS Interface Valves, Pressure Monitors-06-IC-1 E21-R-0004-01 1E21N050 Interlock Setpoints SR TR 3.4.6.2 Function TR 3.4.6-2.1 LPCS System Valves E21-F005 TO E21-F006 Emergency Core Cooling Systems (ECCS)

Instrumentation 06-IC-1 E21-R-2002-01 1E21N052 Automatic Depressurization System (ADS)

SR 3.3.5.1.5 06-IC-1 E21-R-2002-02 1E21N053 Trip System A Function 3.3.5.1-1.4.e LPCS Pump Discharge Pressure - High Reactor Coolant System Instrumentation RCS Interface Valves, Pressure Monitors-Alarm Setpoints LPCS System Valves SR TR 3.4.6.2 E21-F005 TO E21-F006 Function TR 3.4.6-3.1 Emergency Core Cooling Systems (ECCS)

SR TR 3.5.1.6 06-IC-1 E21-R-0001-01 1E21N054 and Reactor Core Isolation Cooling (RCIC)

Function TR 3.5.1.6.a System ECCS-Alarm and Monitoring Instrumentation LPCS System High Pressure Alarm SR TR 3.5.1.9 Function TR 3.5.1.9.b LPCI C Subsystem and LPCS System Low Pressure Alarm Setpoint

DRIFT ANALYSIS ENGINEERING DEPARTMENT GRAND GULF NUCLEAR STATION JC-Q1111-09019 Revision 000 Page 18 of 27 t"~**** :....... Imn::::_4'

'AG**NQ~i TSITRM SECTION IN\\,; 11\\;1"/.'

Emergency Core Cooling Systems (ECCS) and Reactor Core Isolation Cooling (RCIC)

System SR TR 3.5.1.9 06-IC-1 E22-R-0001-1 1E22N050 Function TR 3.5.1.9.c ECCS-Alarm and Monitoring Instrumentation HPCS System Low Pressure Alarm Setpoint Emergency Core Cooling Systems (ECCS)

Instrumentation SR 3.3.5.1.5 06-IC-1 E22-R-0002-01 1E22N054C Function 3.3.5.1-1.3.d 06-IC-1 E22-R-0002-02 1E22N054G High Pressure Core Spray (HPCS) System Condensate Storage Tank Level-Low Primary Containment and Drywell Isolation Instrumentation 06-IC-1 E31-R-1 016-01 1E31N085A SR 3.3.6.1.6 06-IC-1 E31-R-1 016-02 1E31N085B Reactor Core Isolation Cooling (RCIC)

Function 3.3.6.1-1.3.c System Isolation RCIC Steam Supply Line Pressure - Low 06-IC-1 E32-R-1 001-09 1E32N050 Containment Systems 06-IC-1 E32-R-1001-10 1E32N055 06-IC-1 E32-R-1001-11 1E32N058 Main Steam Isolation Valve (MSIV) Leakage 06-IC-1 E32-R-1 001-05 1E32N061A Control System (LCS)

SR TR 3.6.1.9.7 06-IC-1 E32-R-1001-06 1E32N061E 06-IC-1 E32-R-1001-07 1E32N061J Inboard and outboard pressure 06-IC-1 E32-R-1001-08 1E32N061N Instrumentation Reactor Core Isolation Cooling (RCIC) 06-IC-1 E51-R-0002-01 1E51N035A System Instrumentation SR 3.3.5.2.4 06-IC-1 E51-R-0002-02 1E51N035E Function 3.3.5.2-1.3 Condensate Storage Tank Level-Low Primary Containment and Drywell Isolation Instrumentation 06-IC-1 E51-R-0001-01 1E51N055A 06-IC-1 E51-R-0001-02 1E51N055B Reactor Core Isolation Cooling (RCIC)

SR 3.3.6.1.6 06-IC-1 E51-R-0001-03 1E51N055E System Isolation Function 3.3.6.1-1.3.d 06-IC-1 E51-R-0001-04 1E51N055F RCIC Turbine Exhaust Diaphragm Pressure - High

DRIFT ANALYSIS ENGINEERING DEPARTMENT GRAND GULF NUCLEAR STATION 2

Conclusions JC*Q1111-Q9019 Revision 000 Page 19 of 27 2.1 The bounding Analyzed Drift (DA) for the Rosemount Range Codes 5-8 Gage Pressure Transmitters (See Table 1.2-1) has been determined to be +/-1.346% Span for 30 months (24 months + 25%

), with no significant bias. The Analyzed Drift should be treated as a normally distributed, 20' value for uncertainty analysis.

2.2 The results of this analysis can be conservatively applied to all of the Rosemount Range Codes 5-8 Gage Pressure Transmitters in Table 1.2-1 and to any Rosemount Range Codes 5-8 Gage Pressure Transmitter used at Grand Gulf Nuclear Station, which meets the criteria listed in Section 3.5.3 of Reference 4.1.3, "Considerations When Combining Components Into a Single Group".

3 Design Inputs 3.1 Pages 1 through 31 of Attachment 1 provide a listing of the scaling information for the transmitters within this study, giving the input pressure values and output current values for each calibration point, as obtained from Reference 4.2.

3.2 Pages 32 through 62 of Attachment 1 provide a listing of the historical As Left (AL) and As Found (AF) data, as obtained from Reference 4.2, with any data exclusions or modifications noted. All dates of calibration are also entered to provide time intervals between calibrations.

4 References 4.1 METHODOLOGY 4.1.1 ANSIIISA-S67.04-Part 1-2000, "Setpoints for Nuclear Safety Related Instrumentation" 4.1.2 ISA-RP67.04-Part 11-2000, "Methodologies for the Determination of Setpoints for Nuclear Safety-Related Instrumentation" 4.1.3 ECH-NE-08-00015, "Instrument Drift Analysis Design Guide," Rev. 001 4.1.4 EPRI TR-103335R1, "Statistical Analysis of Instrument Calibration Data; Guidelines for Instrument Calibration Extension / Reduction Programs," October 1998 4.1.5 DOE Research and Development Report No. WAPD-TM-1292, "Statistics for Nuclear Engineers and Scientists Part 1: Basic Statistical Inference," February 1981 4.1.6 NRC Generic Letter 91-04, "Changes in Technical Specification Surveillance Requirements to Accommodate a 24 Month Fuel Cycle," April 2, 1991 4.1.7 American National Standard N15.15-1974, "Assessment of the Assumption of Normality (Employing Individual Observed Values)"

DRIFT ANALYSIS ENGINEERING DEPARTMENT GRAND GULF NUCLEAR STATION JC*Q1111*09019 Revision 000 Page 20 of 27 4.2 PROCEDURES Historical Calibration Records from GGNS Surveillance Test Procedure Results for 06-IC-1821-R-0010, 06-IC-1C61-R-0006, 06-IC-1E12-R-0001, 06-IC-1E12-R-1010, 06-IC-1E12-R-1011, 06-IC-1E12-R-2002, 06-IC-1E21-R-0001, 06-IC-1E21-R-0004, 06-IC-1E21-R-2002, 06-IC-1 E22-R-0001, 06-IC-1 E22-R-0002, 06-IC-1 E31-R-1 016, 06-IC-1E32-R-1001, 06-IC-1 E51-R-0001, and 06-IC-1 E51-R-0002.

4.3 MISCELLANEOUS REFERENCES 4.3.1 None 5

Assumptions 5.1 This drift report employs those assumptions customarily used for standard statistical analyses, as directed by Reference 4.1.3, such as the assumption that a distribution is normal and the use of statistical tests to confirm this hypothesis.

5.2 This drift report is based on analysis of historical As Found and As Left data from calibration records for the Rosemount Range Codes 5-8 Gage Pressure Transmitters listed in Table 1.2-1. The results of this analysis can also apply to any Rosemount Range Codes 5-8 Gage Pressure Transmitter used at GGNS, but care must be taken when applying these results. Specifically, in order to apply the results of this analysis to other similar devices, the devices must meet the criteria listed in Section 3.5.3 of Reference 4.1.3, "Considerations When Combining Components Into a Single Group".

6 Method of Analysis 6.1 The methodology used for this analysis is Reference 4.1.3, which is written in accordance with Reference 4.1.4, using References 4.1.1,4.1.2 and 4.1.7 to supplement. An overview of the methodology is given herein, and any deviation from Reference 4.1.3 or any supplemental methods used herein are described.

6.2 This analysis determines the drift values for the subject instrumentation by analysis of historical As Found I As Left data from calibration records. Drift for a given device for a calibration period is determined by subtracting the previous As Left setting from a more recent As Found setting. The time interval for that calibration period is determined by subtracting the previous date from the more recent date, in units of days. All retrievable As Left and As Found data is collected for each calibration performed on each device covered by this report, for the study period. From this information, the drift and calibration interval is generated for each possible instance. Per Section 3.4.2.1 of Reference 4.1.3, "The goal is to collect enough data for the instrument or group of instruments to make a statistically valid pool." The devices covered by this report are currently calibrated on an 18 Month basis, and the proposed extension is for a 24 Month nominal calibration interval. Therefore, a study period of approximately 12 years represents eight of the present calibration cycles, and six of the proposed calibration cycles, which is adequate to understand the component's performance over time. Also, a sufficient number of valid drift values are provided as a result of the selected study

DRIFT ANALYSIS ENGINEERING DEPARTMENT GRAND GULF NUCLEAR STATION JC*Q1111*09019 Revision 000 Page 21 of 27 period to make a statistically valid pool. Therefore, As Found and As Left Data values are entered from calibrations occurring for approximately the last 12 years.

6.3 Determination of the Analyzed Drift is generally accomplished through the following steps.

6.3.1 Gather and Generate Raw Drift Data: In addition to gathering the As Found and As Left data, and computing the drift values and time intervals, this step also involves an investigation into whether all of the devices should be analyzed together, or whether they should be separated into smaller analysis groups. Finally, this step involves careful screening of the input data for errors or other situations that could disrupt the proper determination of drift.

6.3.2 Determination of Outliers and Statistical Summary: In order to properly model the drift characteristics for a device, it could be proper to remove up to one more data value, which obviously does not conform to the vast majority of the data. A t-Test is performed on the data to detect any outliers, and remove up to one if appropriate, per the guidelines of Reference 4.1.3. Additionally, the basic statistical values which describe the group of drift data are derived in this step, including such parameters as Mean, Standard Deviation, Count, Median, Minimum, Maximum, etc.

Finally, within this step, since the subject devices are calibrated at multiple points along the instrument span, the drift statistics from each of the calibration points are compared to choose the worst-case for establishment of the Analyzed Drift (DA) value. The remainder of the drift analysis is based on the drift data from that worst-case calibration point.

6.3.3 Tests for Normality: Per Reference 4.1.3, a statistical test (W or D-Prime, depending on sample size) is performed on the drift data to support the hypothesis that the data conforms to a normal distribution. If this test is unable to support that hypothesis, then a Coverage Analysis is performed to ensure that the data can be conservatively modeled by a normal distribution and to provide an adjustment to the standard deviation of the drift model, if necessary to conservatively envelop the observed data population.

6.3.4 Time-Dependency

Per Reference 4.1.3, Scatter Plots and a time-based Binning Analysis are developed for the data to establish the time-dependency of the drift. If enough drift data exists for significantly different time intervals, regression analysis is performed to aid in the determination of time-dependency. The drift data is determined to be strongly time dependent or moderately time dependent, for the purpose of extrapolation.

6.3.5 Analyzed Drift Derivation and Characterization: The drift values are determined for the current calibration interval. These values are conservatively extrapolated to the desired calibration interval, based on the methods prescribed in Reference 4.1.3, depending on the degree of time-dependency derived for the drift data.

6.4 The mathematical computations of the statistical analysis are performed within an Excel spreadsheet. Supporting information from the spreadsheet is printed out in the form of to this analysis. Microsoft Excel spreadsheets generally compute values to an approximate 15 decimal resolution, which is well beyond any required rounding for

DRIFT ANALYSIS ENGINEERING DEPARTMENT GRAND GULF NUCLEAR STATION JC-Q1111-09019 Revision 000 Page 22 of 27 engineering analyses. However, for printing and display purposes, most values are displayed to lesser resolution. It is possible that hand computations will produce slightly different results, because of using rounded numbers in initial and intermediate steps, but the Excel computed values are considered highly accurate in comparison.

6.5 Acceptance Criteria: Since the purpose of the analysis is to generate a value and description of the characteristics of the drift of the evaluated make/model, there are no specific acceptance criteria.

7 Analysis 7.1 Gather and Generate Raw Drift Data 7.1.1 Specifically, this analysis addresses Rosemount Range Codes 5-8 Gage Pressure Transmitters, with the tag numbers as shown in Table 1.2-1 of this analysis.

7.1.2 Pages 32 through 62 of Attachment 1 provide a listing of the initial As Found and As Left data from available historical plant calibration records for the subject pressure transmitters. Note that the calibration dates are also recorded, and notes are provided to clarify the activities performed or to provide additional information about the data, as appropriate. This data was entered into an Excel spreadsheet for computation of the drift values, time intervals between calibrations and statistical analysis.

7.1.3 A screening of the initial input data from pages 32 through 62 of Attachment 1 was performed. To help identify erroneous data, an informal critical T-test was performed, with the Critical T values reduced incrementally until approximately 10°./0 of the data population was identified as outliers. Those outliers were researched, and no additional data errors were revealed. As shown in Table 7.1.4-1, data was excluded from this analysis and the reasons are noted in the table. The specific informal T-tests performed are not documented, as they are only used as tools to identify potentially erroneous data and do not contribute to the analysis of the valid data.

7.1.4 Data not entered into the analysis is listed in the table below, showing the reasoning used in not entering the data.

DRIFT ANALYSIS ENGINEERING DEPARTMENT GRAND GULF NUCLEAR STATION Table 7.1.4-1 Data Not Entered in the Drift Analysis JC-Q1111-09019 Revision 000 Page 23 of 27 Procedure-Attachment Tag Surveillance Comments/Disposition Number Date(s)

AF Pt 5 recorded as 22.06. This value is not compatible with a functioning 06-IC-1 E12-R-1 01 0-01 1E12N058A 9/9/02 transmitter or consistent with other AF data points. Correct value is probably 20.06. Data point excluded as erroneous.

For surveillances performed between the dates specified in column 3, 06-IC-1 E22-R-0001-1 1E22N050 9/5/97 -

excluded Data Points 1 & 9. Too great 6/27/08 a difference from Data Points 1 & 9 for all other transmitters in data set.

Insufficient calibration data for these Data Points to support drift analysis.

06-IC-1 E22-R-0002-01 1E22N054C 1/12/07 Exclude all AF data due to calibration data change.

06-IC-1 E22-R-0002-02 1E22N054G 10/20/06 Exclude all AF data due to calibration data change.

06-IC-1 E32-R-1 001-09 1E32N050 3/7/04 Exclude all AF data due to calibration data change.

06-IC-1 E32-R-1001-11 1E32N058 3/5/04 Exclude all AF data due to calibration data change.

06-IC-1 E32-R-1 001-11 1E32N058 11/9/99 AF and AL data excluded due to bad M&TE calibration.

06-IC-1 E32-R-1 001-05 1E32N061A 1/7/05 Exclude all AF data due to calibration data change.

06-IC-1 E32-R-1001-06 1E32N061E 10/28/04 Exclude all AF data due to calibration data change.

06-IC-1 E32-R-1 001-07 1E32N061J 9/29/04 Exclude all AF data due to calibration data change.

06-IC-1 E32-R-1 001-08 1E32N061N 1/7/05 Exclude all AF data due to calibration data change.

06-IC-1 E51-R-0002-01 1E51N035A 8/5/06 Exclude all AF data due to calibration data change.

06-IC-1 E51-R-0002-02 1E51N035E 10/8/06 Exclude all AF data due to calibration data change.

DRIFT ANALYSIS ENGINEERING DEPARTMENT GRAND GULF NUCLEAR STATION JC-Q1111-09019 Revision 000 Page 24 of 27 7.1.5 Per the methodology of Section 4.1.1.11 of Reference 4.1.3, drift is computed by subtracting the As Left data of one calibration from the As Found data of the next calibration, as documented in pages 91 through 99 of Attachment 1. These pages also document the time interval between calibrations (in the number of days and months) by subtracting the As Left date of one calibration from the As Found date of the next calibration, per Section 4.1.1.10 of Reference 4.1.3. Pages 91 through 99 of Attachment 1 derive the drift values and time intervals between calibrations from the data presented on pages 77 through 90 of Attachment 1. As an example of the equations used, the first drift value and time interval are computed as follows. The example uses Calibration Data Point 1. The rest of the values are computed identically.

Drift (Seq 1)

=AF (6/17/09) - AL (8/28/07)

[For Tag 1821 N201A]

=0.12500 (From Seq. 1) - 0.12500 (From Seq. 4)

=0.00000 %Span Cal Interval (Seq 1) =6/17/09 - 8/28/07

=659 Days Cal Interval (Mo.)

=Cal Interval (Days) x 12 Months / 365.25 Days

=21.7 Months 7.1.6 Pooling tests were performed on the data as documented on pages 123 and 124 of. Two pooling tests were performed. The first test compared the three model numbers and the second test compared two groups of turndown ratios.

Pooling Tests Model Comparison Case 1) Rosemount Model 1151 vs. 1152 Case 2) Rosemount Model 1151 vs. 1153 Case 3) Rosemount Model 1152 vs. 1153 Turndown Ratio Comparison Case 4) Turndown Ratio <1.5 vs.

~1.5 The pooling test determines the acceptability of:

1.

combining the data from the different transmitter series into one data set for analysis, and 2.

combining the data from two sets of transmitters with differing turndown ratios.

For each combination, a t Test is performed per Section 3.5.4 of Reference 4.1.3 to determine acceptability for pooling between the groups, as shown on pages 123 and 124 of Attachment 1. For all cases, the t Statistic is less than the t Critical two-tail value, indicating that combination of the groups for analysis is appropriate. From an engineering standpoint, there is little reason that these pressure transmitters should perform differently and all data should combine

DRIFT ANALYSIS ENGINEERING DEPARTMENT GRAND GULF NUCLEAR STATION JC-Q1111-09019 Revision 000 Page 25 of 27 appropriately by units of % Span. The t Tests confirm this hypothesis.

Therefore, all of the data is combined for analysis in units of % Span.

7.2 Determination of Outliers and Statistical Summary 7.2.1 The outlier analysis is recorded on pages 100 through 122 of Attachment 1 to this drift analysis. These pages display the Sequence No., Tag 10, Drift, and Calibration Interval (in units of days). The critical T value used in the outlier analysis comes directly from Table 2 of Reference 4.1.3. As shown on page 122 of Attachment 1, outliers are detected but not removed for Calibration Point 5 in sequence 439, and Calibration Points 4, 5, and 6 in sequence 477. Outliers are detected and removed from the analysis for Calibration Points 1, 2, 3, 4, 5, 6, 7, 8, & 9 in sequence 413 per Section 3.6.3 of Reference 4.1.3. The Final Data Set (FDS) for this analysis is documented on pages 115 through 121 of Attachment 1.

7.2.2 A summary of the required statistical values for each calibration point for the Final Data Set, per Section 4.2 of Reference 4.1.3, is developed within the outlier analysis on page 122 of Attachment 1. Cell formulas for the determinations of statistical quantities are used directly from Section 4.2 of Reference 4.1.3. Per Section 3.6.3 of Reference 4.1.3, the Calibration Data Points are compared by analyzing the "IMeanl+2*Standard Deviation" term. For this set of data, this quantity is largest for Calibration Data Point 5. Therefore, the remainder of the analysis is based on the Final Data Set from Calibration Data Point 5.

7.3 Tests for Normality 7.3.1 Since the FDS contains greater than 50 samples, the D-Prime Test is performed on the data to test for normality, as shown on pages 125 through 129 of Attachment 1.

Per Section 3.7.3 of Reference 4.1.3, the details of the D-Prime test methodology are shown in Reference 4.1.7. Equations used and the results are listed on page 125 of Attachment 1. Since the calculated 0' (815.6) is not within the acceptable range for 268 data points (1219.2 to 1251.0), this test rejects the assumption of normality for this data set.

7.3.2 Since the data does not pass the D-Prime test for normality, a Coverage Analysis is necessary. For the Coverage Analysis, a Histogram is developed on pages 125 and 129 of Attachment 1, per Sections 3.7.5 and 4.4 of Reference 4.1.3. To generate the histogram data, the drift values are categorized into 12 bins, in relation to the mean and standard deviation. These bins are generated in multiples of ~ Standard Deviation increments, and the bin maximum values are derived in accordance with the methods given in Section 19 of Reference 4.1.4. (See column headings for specific formulas used for the Maximums.)

Expected numbers of data points within each bin are calculated, assuming that the data is a normal distribution and that the data set is exactly representative of a normal curve. The population percentages within each bin are derived from Table 18-2 of Reference 4.1.4, which describe the percentage populations within the identified bins. These percentages are then multiplied by the total data population to determine the expected number of values within each bin, for the size of the data set. The observed population within each bin is tabulated and plotted as a bar chart versus the ideal normal curve for comparison.

DRIFT ANALYSIS ENGINEERING DEPARTMENT GRAND GULF NUCLEAR STATION JC*Q1111*09019 Revision 000 Page 26 of 27 The Histogram on page 131 of Attachment 1 shows that the data is zero centric and more peaked in the middle than a normal distribution, as confirmed by the shape and positive Kurtosis value. It is observed that the actual percentage population of data within +/- 2 standard deviations is slightly above than a normal distribution.

Therefore, this data set may conservatively be modeled as a normal distribution, without adjustment to the standard deviation.

7.4 Time-Dependency 7.4.1 In order to determine time-dependency of the drift data, the data is first plotted as a scatter plot on page 132 of Attachment 1, in accordance with the methodology of Section 4.5.1 of Reference 4.1.3. The trend line within this scatter plot starts at a negative value and crosses the x-axis and ends at a positive value within the analysis period. The trend line and associated equation are noted on the scatter plot on page 132 of Attachment 1.

7.4.2 The binning analysis is performed on page 133 of Attachment 1. The drift and time interval data are divided into bins, based on the intervals between calibrations as defined in Section 3.8.3.1 of Reference 4.1.3. Statistical summaries for each bin, including count, mean, standard deviation, mean time interval and maximum observed time interval are computed. Excel functions are used to determine the statistical summary values for each bin, and are used explicitly from Sections 4.2.1, 4.2.2, 4.2.3 and 4.2.7 of Reference 4.1.3. This information is presented on page 133 of Attachment 1. Per Section 3.8.3.4 of Reference 4.1.3, after removing those bins with 5 or less data points and those with less than or equal to 100k of total population, only Bin 5 remains. Therefore, it is concluded that there is not enough diversity in the calibration intervals analyzed to make meaningful conclusions about time dependency from the existing data. Therefore, no more time dependency analysis is performed for this data set. The data is treated as moderately time dependent for the purpose of extrapolation.

7.5 Analyzed Drift (DA) Derivation and Characterization 7.5.1 As shown on page 134 of Attachment 1, per Section 3.10 of Reference 4.1.3, the drift bias error is evaluated for significance. The Significant Bias Critical Value (Xcrit) is computed and compared to the Absolute Value of Average of the Final Data Set.

The bias value for this drift data set is not significant, since the Absolute Value of the Average is less than the Xcrit value. Therefore, the Analyzed Drift Bias term (DAbias) is negligible.

7.5.2 Per Section 4.6.6 of Reference 4.1.3, the random portion of the Analyzed Drift is determined from multiplying the standard deviation of the Final Data Set by the Tolerance Interval Factor (TIF), and extrapolating as required to a calibration interval of 30 months. Since the random portion of drift has been determined to be moderately time-dependent for the purpose of extrapolation, the standard deviation of the Final Data Set is used with the average observed time interval from Bin 5 on page 133 of Attachment 1 as the starting point. The TIF is obtained from Table 1 of Reference 4.1.3 as 2.121 for a 95/95 significance. The computation of this value is shown on page 134 of Attachment 1 to result in a DArandom(extrap) term of +/-1.346%

Span.

DRIFT ANALYSIS ENGINEERING DEPARTMENT GRAND GULF NUCLEAR STATION 8

Attachments - Analysis Spreadsheet (134 pages)

Spreadsheet Contents Input Data Data Conversion AF-AL Data Outliers & Summary Pooling Tests D-Prime Coverage Analysis Scatter Plot Binning Analysis Analyzed Drift (DA) - DVR Form (7 pages)

JC*Q1111*09019 Revision 000 Page 27 of 27 Pages 1-62 63-90 91-99 100-122 123-124 125-129 130-131 132 133 134

DRIFT ANALYSIS ENGINEERING DEPARTMENT GRAND GULF NUCLEAR STATION Rosemount Range Codes 5 - 8 Gage Pressure Transmitters Input Data JC-Q1111-09019 Rev. 0 Page 1 of 134 Instrument I Test Information Scaling Data Seq.

In lOut Pt 1 Pt2 Pt 3 Pt4 Pt 5 Pt6 Pt7 PtB Pt9 10 Tag 10 Oate Procedure-Attachment Make/Model Units (0% Up)

(25% Up)

(50% Up)

(75% Up)

(100% Up)

(75% On)

(50% On)

(25% On)

(0% On) 1 1821N201A 6/17/09 06-IC-1821-R-0010-o1 Rosemount 1153GD7PC psig 0.00 75.00 150.00 225.00 300.00 225.00 150.00 75.00 0.00 2

1821N201A 6/17/09 06-IC-1 821-R-001 0-01 Rosemount 1153GD7PC mA 4.00 8.00 12.00 16.00 20.00 16.00 12.00 8.00 4.00 3

1821N201A 8/28/07 06-IC-1 821-R-001 0-01 Rosemount 1153GD7PC psig 0.00 75.00 150.00 225.00 300.00 225.00 150.00 75.00 0.00 4

1821N201A 8/28/07 06-IC-1 821-R-001 0-01 Rosemount 1153GD7PC mA 4.00 8.00 12.00 16.00 20.00 16.00 12.00 8.00 4.00 5

1821N201A 11/8/05 06-IC-1 821-R-001 0-01 Rosemount 1153GD7PC psig 0.00 75.00 150.00 225.00 300.00 225.00 150.00 75.00 0.00 6

1821N201A 11/8/05 06-IC-1821-R-0010-01 Rosemount 1153GD7PC mA 4.00 8.00 12.00 16.00 20.00 16.00 12.00 8.00 4.00 7

1821N201A 5/11/04 06-IC-1821-R-0010-01 Rosemount 1153GD7PC psig 0.00 75.00 150.00 225.00 300.00 225.00 150.00 75.00 0.00 8

1821N201A 5/11/04 06-IC-1 821-R-001 0-01 Rosemount 1153GD7PC mA 4.00 8.00 12.00 16.00 20.00 16.00 12.00 8.00 4.00 9

1821N201A 11/25/02 06-1C-1 821-R-0010-01 Rosemount 1153GD7PC psig 0.00 75.00 150.00 225.00 300.00 225.00 150.00 75.00 0.00 10 1821N201A 11/25/02 06-IC-1 821-R-0010-01 Rosemount 1153GD7PC mA 4.00 8.00 12.00 16.00 20.00 16.00 12.00 8.00 4.00 11 1821N201A 4/24/01 06-IC-1821-R-0010-01 Rosemount 1153GD7PC psig 0.00 75.00 150.00 225.00 300.00 225.00 150.00 75.00 0.00 12 1821N201A 4/24/01 06-IC-1821-R-0010-01 Rosemount 1153GD7PC mA 4.00 8.00 12.00 16.00 20.00 16.00 12.00 8.00 4.00 13 1821N201A 10/28/99 06-IC-1821-R-0010-01 Rosemount 1153GD7PC psig 0.00 75.00 150.00 225.00 300.00 225.00 150.00 75.00 0.00 14 1821N201A 10/28/99 06-IC-1 821-R-001 0-01 Rosemount 1153GD7PC mA 4.00 8.00 12.00 16.00 20.00 16.00 12.00 8.00 4.00 15 1821N201A 4/21/98 06-IC-1821-R-0010-01 Rosemount 1153GD7PC psig 0.00 75.00 150.00 225.00 300.00 225.00 150.00 75.00 0.00 16 1821N201A 4/21/98 06-IC-1 821-R-001 0-01 Rosemount 1153GD7PC mA 4.00 8.00 12.00 16.00 20.00 16.00 12.00 8.00 4.00 17 1821N2018 12/3/10 06-IC-1821-R-0010-02 Rosemount 1153GD7PC psig 0.00 75.00 150.00 225.00 300.00 225.00 150.00 75.00 0.00 18 1821N2018 12/3/10 06-IC-1821-R-0010-02 Rosemount 1153GD7PC mA 4.00 8.00 12.00 16.00 20.00 16.00 12.00 8.00 4.00 19 1821N2018 3/31/09 06-IC-1 821-R-001 0-02 Rosemount 1153GD7PC psig 0.00 75.00 150.00 225.00 300.00 225.00 150.00 75.00 0.00 20 1821N2018 3/31/09 06-IC-1821-R-0010-02 Rosemount 1153GD7PC mA 4.00 8.00 12.00 16.00 20.00 16.00 12.00 8.00 4.00 21 1821N2018 10/12107 06-IC-1821-R-0010-02 Rosemount 1153GD7PC psig 0.00 75.00 150.00 225.00 300.00 225.00 150.00 75.00 0.00 22 1821N2018 10/12107 06-IC-1821-R-0010-02 Rosemount 1153GD7PC mA 4.00 8.00 12.00 16.00 20.00 16.00 12.00 8.00 4.00

DRIFT ANALYSIS ENGINEERING DEPARTMENT GRAND GULF NUCLEAR STATION Rosemount Range Codes 5 - 8 Gage Pressure Transmitters Input Data JC-Q1111-09019 Rev. 0 Page 2 of 134 Instrument I Test Information Scaling Data Seq.

In lOut Pt 1 Pt2 Pt 3 Pt4 Pt5 Pt 6 Pt7 PtS Pt9 10 Tag 10 Date Procedure-Attachment Make IModel Units (0% Up)

(25% Up)

(50% Up)

(75% Up)

(100% Up)

(75% On)

(50% On)

(25% On)

(0% On) 23 1B21N201B 3/8/06 06-IC-1 B21-R-0010-02 Rosemount 1153GD7PC psig 0.00 75.00 150.00 225.00 300.00 225.00 150.00 75.00 0.00 24 1B21N201B 3/8/06 06-IC-1 B21-R-0010-02 Rosemount 1153GD7PC mA 4.00 8.00 12.00 16.00 20.00 16.00 12.00 8.00 4.00 25 1B21N201B 7/15/04 06-1C-1 B21-R-0010-02 Rosemount 1153GD7PC psig 0.00 75.00 150.00 225.00 300.00 225.00 150.00 75.00 0.00 26 1B21N201B 7/15/04 06-IC-1 B21-R-0010-02 Rosemount 1153GD7PC mA 4.00 8.00 12.00 16.00 20.00 16.00 12.00 8.00 4.00 27 1B21N201B 10/24/02 06-IC-1 B21-R-001 0-02 Rosemount 1153GD7PC psig 0.00 75.00 150.00 225.00 300.00 225.00 150.00 75.00 0.00 28 1B21N201B 10/24/02 06-IC-1B21-R-0010-02 Rosemount 1153GD7PC mA 4.00 8.00 12.00 16.00 20.00 16.00 12.00 8.00 4.00 29 1B21N201B 4/23/01 06-IC-1 B21-R-0010-02 Rosemount 1153GD7PC psig 0.00 75.00 150.00 225.00 300.00 225.00 150.00 75.00 0.00 30 1B21N201B 4/23/01 06-IC-1 B21-R-001 0-02 Rosemount 1153GD7PC mA 4.00 8.00 12.00 16.00 20.00 16.00 12.00 8.00 4.00 31 1B21N201B 11/5/99 06-IC-1B21-R-0010-02 Rosemount 1153GD7PC psig 0.00 75.00 150.00 225.00 300.00 225.00 150.00 75.00 0.00 32 1B21N201B 11/5/99 06-IC-1 B21-R-001 0-02 Rosemount 1153GD7PC mA 4.00 8.00 12.00 16.00 20.00 16.00 12.00 8.00 4.00 33 1B21N201B 4/16/98 06-IC-1 B21-R-001 0-02 Rosemount 1153GD7PC psig 0.00 75.00 150.00 225.00 300.00 225.00 150.00 75.00 0.00 34 1B21N201B 4/16/98 06-IC-1 B21-R-001 0-02 Rosemount 1153GD7PC mA 4.00 8.00 12.00 16.00 20.00 16.00 12.00 8.00 4.00 35 1C61N102 8/12/09 06-1C-1 C61-R-0006-01 Rosemount 1153GB5 InWC 13.50 132.90 252.30 371.70 491.20 371.70 252.30 132.90 13.50 36 1C61N102 8/12/09 06-IC-1 C61-R-0006-01 Rosemount 1153GB5 mA 4.00 8.00 12.00 16.00 20.00 16.00 12.00 8.00 4.00 37 1C61N102 2/15/08 06-1C-1 C61-R-0006-01 Rosemount 1153GB5 InWC 13.50 132.90 252.30 371.70 491.20 371.70 252.30 132.90 13.50 38 1C61N102 2/15/08 06-1C-1 C61-R-0006-01 Rosemount 1153GB5 mA 4.00 8.00 12.00 16.00 20.00 16.00 12.00 8.00 4.00 39 1C61N102 8/31/06 06-1C-1 C61-R-0006-01 Rosemount 1153GB5 InWC 13.50 132.90 252.30 371.70 491.20 371.70 252.30 132.90 13.50 40 1C61N102 8/31/06 06-IC-1C61-R-0006-01 Rosemount 1153GB5 rnA 4.00 8.00 12.00 16.00 20.00 16.00 12.00 8.00 4.00 41 1C61N102 1/19/05 06-1C-1 C61-R-0006-01 Rosemount 1153GB5 InWC 13.50 132.90 252.30 371.70 491.20 371.70 252.30 132.90 13.50 42 1C61N102 1/19/05 06-IC-1 C61-R-0006-01 Rosemount 1153GB5 mA 4.00 8.00 12.00 16.00 20.00 16.00 12.00 8.00 4.00 43 1C61N102 8/7/03 06-IC-1 C61-R-0006-01 Rosemount 1153GB5 InWC 13.50 132.90 252.30 371.70 491.20 371.70 252.30 132.90 13.50 44 1C61N102 8/7/03 06-1C-1 C61-R-0006-01 Rosemount 1153GB5 mA 4.00 8.00 12.00 16.00 20.00 16.00 12.00 8.00 4.00

DRIFT ANALYSIS ENGINEERING DEPARTMENT GRAND GULF NUCLEAR STATION Rosemount Range Codes 5 - 8 Gage Pressure Transmitters Input Data JC-Q1111-09019 Rev. 0 Page 3 of 134 Instrument I Test Information Scaling Data Seq.

In / Out Pt 1 Pt2 Pt 3 Pt4 Pt 5 Pt6 Pt7 Pt 8 Pt9 10 Tag 10 Date Procedure-Attachment Make/Model Units (0% Up)

(25% Up)

(50% Up)

(75% Up)

(100% Up)

(75% On)

(50% On)

(25% On)

(0% On) 45 1C61N102 2/8/02 06-1C-1 C61-R-0006-01 Rosemount 1153GB5 InWC 13.50 132.90 252.30 371.70 491.20 371.70 252.30 132.90 13.50 46 1C61N102 2/8/02 06-IC-1 C61-R-0006-01 Rosemount 1153GB5 rnA 4.00 8.00 12.00 16.00 20.00 16.00 12.00 8.00 4.00 47 1C61N102 8/15/00 06-IC-1 C61-R-0006-01 Rosemount 1153GB5 InWC 13.50 132.90 252.30 371.70 491.20 371.70 252.30 132.90 13.50 48 1C61N102 8115/00 06-IC-1 C61-R-0006-01 Rosemount 1153GB5 rnA 4.00 8.00 12.00 16.00 20.00 16.00 12.00 8.00 4.00 49 1C61N102 3/29/99 06-IC-1 C61-R-0006-01 Rosemount 1153GB5 InWC 13.50 132.90 252.30 371.70 491.20 371.70 252.30 132.90 13.50 50 1C61N102 3/29/99 06-IC-1C61-R-0006-01 Rosemount 1153GB5 rnA 4.00 8.00 12.00 16.00 20.00 16.00 12.00 8.00 4.00 51 1E12N053A 8/12/09 06-IC-1 E12-R-0001-01 Rosemount 1151 GP8A22 psig 0.00 119.60 244.60 369.60 494.60 369.60 244.60 119.60 0.00 52 1E12N053A 8/12109 06-IC-1 E12-R-0001-01 Rosemount 1151GP8A22 rnA 4.17 8.00 12.00 16.00 20.00 16.00 12.00 8.00 4.17 53 1E12N053A 2115/08 06-IC-1 E12-R-0001-01 Rosemount 1151 GP8A22 psig 0.00 119.60 244.60 369.60 494.60 369.60 244.60 119.60 0.00 54 1E12N053A 2115/08 06-IC-1 E12-R-0001-01 Rosemount 1151 GP8A22 rnA 4.17 8.00 12.00 16.00 20.00 16.00 12.00 8.00 4.17 55 1E12N053A 8/30/06 06-IC-1 E12-R-0001-01 Rosemount 1151GP8A22 psig 0.00 119.60 244.60 369.60 494.60 369.60 244.60 119.60 0.00 56 1E12N053A 8/30/06 06-IC-1 E12-R-0001-01 Rosemount 1151GP8A22 rnA 4.17 8.00 12.00 16.00 20.00 16.00 12.00 8.00 4.17 57 1E12N053A 3/17/05 06-IC-1E12-R-0001-01 Rosemount 1151GP8A22 psig 0.00 119.60 244.60 369.60 494.60 369.60 244.60 119.60 0.00 58 1E12N053A 3/17/05 06-IC-1 E12-R-0001-01 Rosemount 1151GP8A22 rnA 4.17 8.00 12.00 16.00 20.00 16.00 12.00 8.00 4.17 59 1E12N053A 10/3/03 06-IC-1 E12-R-0001-01 Rosemount 1151GP8A22 psig 0.00 119.60 244.60 369.60 494.60 369.60 244.60 119.60 0.00 60 1E12N053A 10/3/03 06-IC-1 E12-R-0001-01 Rosemount 1151GP8A22 rnA 4.17 8.00 12.00 16.00 20.00 16.00 12.00 8.00 4.17 61 1E12N053A 4/17/02 06-IC-1E12-R-0001-01 Rosemount 1151GP8A22 psig 0.00 119.60 244.60 369.60 494.60 369.60 244.60 119.60 0.00 62 1E12N053A 4/17/02 06-IC-1E12-R-0001-01 Rosemount 1151GP8A22 rnA 4.17 8.00 12.00 16.00 20.00 16.00 12.00 8.00 4.17 63 1E12N053A 10/16/00 06-IC-1 E12-R-0001-01 Rosemount 1151 GP8A22 psig 0.00 119.60 244.60 369.60 494.60 369.60 244.60 119.60 0.00 64 1E12N053A 10/16/00 06-IC-1 E12-R-0001-01 Rosemount 1151 GP8A22 rnA 4.17 8.00 12.00 16.00 20.00 16.00 12.00 8.00 4.17 65 1E12N053A 3/22/99 06-IC-1 E12-R-0001-01 Rosemount 1151GP8A22 psig 0.00 119.60 244.60 369.60 494.60 369.60 244.60 119.60 0.00 66 1E12N053A 3/22199 06-IC-1 E12-R-0001-01 Rosemount 1151GP8A22 rnA 4.17 8.00 12.00 16.00 20.00 16.00 12.00 8.00 4.17

DRIFT ANALYSIS ENGINEERING DEPARTMENT GRAND GULF NUCLEAR STATION Rosemount Range Codes 5 - 8 Gage Pressure Transmitters Input Data JC-Q1111-09019 Rev. 0 Page 4 of 134 Instrument I Test Information Scaling Data Seq.

In lOut Pt 1 Pt2 Pt3 Pt4 Pt5 Pt6 Pt7 pta Pt9 10 Tag 10 Date Procedure-Attachment Make/Model Units (0% Up)

(25% Up)

(50% Up)

(75% Up)

(100% Up)

(75% On)

(50% On)

(25% On)

(0% On) 67 1E12N053A 8/26/97 06-IC-1 E12-R-0001-01 Rosemount 1151GP8A22 psig 0.00 119.60 244.60 369.60 494.60 369.60 244.60 119.60 0.00 68 1E12N053A 8/26/97 06-IC-1 E12-R-0001-01 Rosemount 1151GP8A22 rnA 4.17 8.00 12.00 16.00 20.00 16.00 12.00 8.00 4.17 69 1E12N0538 12/14/09 06-IC-1 E12-R-0001-02 Rosemount 1151 GP8A22 psig 0.00 119.50 244.50 369.50 494.50 369.50 244.50 119.50 0.00 70 1E12N0538 12/14/09 06-IC-1 E12-R-0001-02 Rosemount 1151GP8A22 rnA 4.18 8.00 12.00 16.00 20.00 16.00 12.00 8.00 4.18 71 1E12N0538 5/29/08 06-IC-1 E12-R-0001-02 Rosemount 1151GP8A22 psig 0.00 119.50 244.50 369.50 494.50 369.50 244.50 119.50 0.00 72 1E12N0538 5/29/08 06-IC-1 E12-R-0001-02 Rosemount 1151GP8A22 rnA 4.18 8.00 12.00 16.00 20.00 16.00 12.00 8.00 4.18 73 1E12N0538 11/29/06 06-IC-1 E12-R-0001-02 Rosemount 1151GP8A22 psig 0.00 119.50 244.50 369.50 494.50 369.50 244.50 119.50 0.00 74 1E12N0538 11/29/06 06-IC-1 E12-R-0001-02 Rosemount 1151GP8A22 rnA 4.18 8.00 12.00 16.00 20.00 16.00 12.00 8.00 4.18 75 1E12N0538 5/20/05 06-IC-1 E12-R-0001-02 Rosemount 1151 GP8A22 psig 0.00 119.50 244.50 369.50 494.50 369.50 244.50 119.50 0.00 76 1E12N0538 5/20/05 06-IC-1E12-R-0001-02 Rosemount 1151GP8A22 rnA 4.18 8.00 12.00 16.00 20.00 16.00 12.00 8.00 4.18 77 1E12N0538 11/20/03 06-IC-1 E12-R-0001-02 Rosemount 1151 GP8A22 psig 0.00 119.50 244.50 369.50 494.50 369.50 244.50 119.50 0.00 78 1E12N0538 11/20/03 06-IC-1 E12-R-0001-02 Rosemount 1151GP8A22 rnA 4.18 8.00 12.00 16.00 20.00 16.00 12.00 8.00 4.18 79 1E12N0538 7/17/02 06-IC-1E12-R-0001-02 Rosemount 1151GP8A22 psig 0.00 119.50 244.50 369.50 494.50 369.50 244.50 119.50 0.00 80 1E12N0538 7/17/02 06-IC-1 E12-R-0001-02 Rosemount 1151 GP8A22 rnA 4.18 8.00 12.00 16.00 20.00 16.00 12.00 8.00 4.18 81 1E12N0538 9/28/00 06-IC-1 E12-R-0001-02 Rosemount 1151GP8A22 psig 0.00 119.50 244.50 369.50 494.50 369.50 244.50 119.50 0.00 82 1E12N0538 9/28/00 06-IC-1 E12-R-0001-Q2 Rosemount 1151GP8A22 rnA 4.18 8.00 12.00 16.00 20.00 16.00 12.00 8.00 4.18 83 1E12N0538 3/18/99 06-IC-1 E12-R-0001-02 Rosemount 1151GP8A22 psig 0.00 119.50 244.50 369.50 494.50 369.50 244.50 119.50 0.00 84 1E12N0538 3/18/99 06-IC-1 E12-R-0001-02 Rosemount 1151GP8A22 rnA 4.18 8.00 12.00 16.00 20.00 16.00 12.00 8.00 4.18 85 1E12N0538 8/20/97 06-IC-1 E12-R-0001-02 Rosemount 1151 GP8A22 psig 0.00 119.50 244.50 369.50 494.50 369.50 244.50 119.50 0.00 86 1E12N0538 8/20/97 06-IC-1 E12-R-0001-02 Rosemount 1151GP8A22 rnA 4.18 8.00 12.00 16.00 20.00 16.00 12.00 8.00 4.18 87 1E12N053C 11/4/10 06-IC-1 E12-R-0001-Q3 Rosemount 1151 GP8A22 psig 0.00 123.70 248.70 373.70 498.70 373.70 248.70 123.70 0.00 88 1E12N053C 11/4/10 06-IC-1 E12-R-0001-03 Rosemount 1151 GP8A22 rnA 4.04 8.00 12.00 16.00 20.00 16.00 12.00 8.00 4.04

DRIFT ANALYSIS ENGINEERING DEPARTMENT GRAND GULF NUCLEAR STATION Rosemount Range Codes 5 - 8 Gage Pressure Transmitters Input Data JC-Q1111-09019 Rev. 0 Page 5 of 134 Instrument I Test Information Scaling Data Seq.

In / Out Pt 1 Pt2 Pt3 Pt4 Pt5 Pt 6 Pt7 Pt8 Pt9 10 Tag 10 Oate Procedure-Attachment Make/Model Units (0% Up)

(25% Up)

(50% Up)

(75% Up)

(100% Up)

(75% On)

(50% On)

(25% On)

(0% On) 89 1E12N053C 5/11/09 06-IC-1 E12-R-0001-03 Rosemount 1151GP8A22 psig 0.00 123.70 248.70 373.70 498.70 373.70 248.70 123.70 0.00 90 1E12N053C 5/11/09 06-IC-1 E12-R-0001-03 Rosemount 1151GP8A22 rnA 4.04 8.00 12.00 16.00 20.00 16.00 12.00 8.00 4.04 91 1E12N053C 9/17/07 06-IC-1 E12-R-0001-03 Rosemount 1151GP8A22 psig 0.00 123.70 248.70 373.70 498.70 373.70 248.70 123.70 0.00 92 1E12N053C 9/17/07 06-IC-1 E12-R-0001-03 Rosemount 1151GP8A22 rnA 4.04 8.00 12.00 16.00 20.00 16.00 12.00 8.00 4.04 93 1E12N053C 1/23/06 06-IC-1 E12-R-0001-03 Rosemount 1151 GP8A22 psig 0.00 123.70 248.70 373.70 498.70 373.70 248.70 123.70 0.00 94 1E12N053C 1/23/06 06-IC-1 E12-R-0001-03 Rosemount 1151GP8A22 rnA 4.04 8.00 12.00 16.00 20.00 16.00 12.00 8.00 4.04 95 1E12N053C 417104 06-IC-1 E12-R-0001-03 Rosemount 1151GP8A22 psig 0.00 123.70 248.70 373.70 498.70 373.70 248.70 123.70 0.00 96 1E12N053C 4/7/04 06-IC-1 E12-R-0001-03 Rosemount 1151 GP8A22 rnA 4.04 8.00 12.00 16.00 20.00 16.00 12.00 8.00 4.04 97 1E12N053C 7/17/02 06-IC-1E12-R-0001-03 Rosemount 1151GP8A22 psig 0.00 123.70 248.70 373.70 498.70 373.70 248.70 123.70 0.00 98 1E12N053C 7/17/02 06-IC-1 E12-R-0001-03 Rosemount 1151 GP8A22 rnA 4.04 8.00 12.00 16.00 20.00 16.00 12.00 8.00 4.04 99 1E12N053C 10/24/00 06-IC-1 E12-R-0001-03 Rosemount 1151GP8A22 psig 0.00 123.70 248.70 373.70 498.70 373.70 248.70 123.70 0.00 100 1E12N053C 10/24/00 06-IC-1 E12-R-0001-03 Rosemount 1151GP8A22 rnA 4.04 8.00 12.00 16.00 20.00 16.00 12.00 8.00 4.04 101 1E12N053C 3/18/99 06-IC-1 E12-R-0001-03 Rosemount 1151 GP8A22 psig 0.00 123.70 248.70 373.70 498.70 373.70 248.70 123.70 0.00 102 1E12N053C 3/18/99 06-IC-1 E12-R-0001-Q3 Rosemount 1151GP8A22 rnA 4.04 8.00 12.00 16.00 20.00 16.00 12.00 8.00 4.04 103 1E12N053C 8/20/97 06-IC-1E12-R-0001-03 Rosemount 1151 GP8A22 psig 0.00 123.70 248.70 373.70 498.70 373.70 248.70 123.70 0.00 104 1E12N053C 8/20/97 06-IC-1 E12-R-0001-03 Rosemount 1151GP8A22 rnA 4.04 8.00 12.00 16.00 20.00 16.00 12.00 8.00 4.04 105 1E12N055A 12122/09 06-IC-1E12-R-2002-04 Rosemount 1152GP7-N22 psig 0.00 57.60 120.10 182.60 245.10 182.60 120.10 57.60 0.00 106 1E12N055A 12122/09 06-IC-1 E12-R-2002-04 Rosemount 1152GP7-N22 rnA 4.31 8.00 12.00 16.00 20.00 16.00 12.00 8.00 4.31 107 1E12N055A 6/30/08 06-IC-1 E12-R-2002-Q4 Rosemount 1152GP7-N22 psig 0.00 57.60 120.10 182.60 245.10 182.60 120.10 57.60 0.00 108 1E12N055A 6/30/08 06-IC-1 E12-R-2002-04 Rosemount 1152GP7-N22 rnA 4.31 8.00 12.00 16.00 20.00 16.00 12.00 8.00 4.31 109 1E12N055A 9/14/06 06-IC-1 E12-R-2002-04 Rosemount 1152GP7-N22 psig 0.00 57.60 120.10 182.60 245.10 182.60 120.10 57.60 0.00 110 1E12N055A 9/14/06 06-IC-1E12-R-2002-Q4 Rosemount 1152GP7-N22 rnA 4.31 8.00 12.00 16.00 20.00 16.00 12.00 8.00 4.31

DRIFT ANALYSIS ENGINEERING DEPARTMENT GRAND GULF NUCLEAR STATION Rosemount Range Codes 5 - 8 Gage Pressure Transmitters Input Data JC-Q1111-09019 Rev. 0 Page 6 of 134 Instrument I Test Information Scaling Data Seq.

In / Out Pt1 Pt2 Pt 3 Pt4 Pt5 Pt6 Pt7 PtB Ptg 10 Tag 10 Date Procedure-Attachment Make/Model Units (0% Up)

(25% Up)

(50% Up)

(75% Up)

(100% Up)

(75% On)

(50% On)

(25% On)

(0% On) 111 1E12N055A 1/17/05 06-IC-1 E12-R-2002-04 Rosemount 1152GP7-N22 psig 0.00 57.60 120.10 182.60 245.10 182.60 120.10 57.60 0.00 112 1E12N055A 1/17/05 06-IC-1E12-R-2002-04 Rosemount 1152GP7-N22 rnA 4.31 8.00 12.00 16.00 20.00 16.00 12.00 8.00 4.31 113 1E12N055A 9/3/03 06-IC-1 E12-R-2002-04 Rosemount 1152GP7-N22 psig 0.00 57.60 120.10 182.60 245.10 182.60 120.10 57.60 0.00 114 1E12N055A 9/3/03 06-IC-1 E12-R-2002-04 Rosemount 1152GP7-N22 rnA 4.31 8.00 12.00 16.00 20.00 16.00 12.00 8.00 4.31 115 1E12N055A 3/8/02 06-IC-1 E12-R-2002-04 Rosemount 1152GP7-N22 psig 0.00 57.60 120.10 182.60 245.10 182.60 120.10 57.60 0.00 116 1E12N055A 3/8/02 06-IC-1 E12-R-2002-04 Rosemount 1152GP7-N22 rnA 4.31 8.00 12.00 16.00 20.00 16.00 12.00 8.00 4.31 117 1E12N055A 10/4/00 06-IC-1 E12-R-2002-04 Rosemount 1152GP7-N22 psig 0.00 57.60 120.10 182.60 245.10 182.60 120.10 57.60 0.00 118 1E12N055A 10/4/00 06-IC-1 E12-R-2002-04 Rosemount 1152GP7-N22 rnA 4.31 8.00 12.00 16.00 20.00 16.00 12.00 8.00 4.31 119 1E12N055A 4/11/99 06-IC-1 E12-R-2002-04 Rosemount 1152GP7-N22 psig 0.00 57.60 120.10 182.60 245.10 182.60 120.10 57.60 0.00 120 1E12N055A 4/11/99 06-IC-1 E12-R-2002-04 Rosemount 1152GP7-N22 rnA 4.31 8.00 12.00 16.00 20.00 16.00 12.00 8.00 4.31 121 1E12N055A 8/30/97 06-IC-1 E12-R-2002-Q4 Rosemount 1152GP7-N22 psig 0.00 57.60 120.10 182.60 245.10 182.60 120.10 57.60 0.00 122 1E12N055A 8/30/97 06-IC-1E12-R-2002-04 Rosemount 1152GP7-N22 rnA 4.31 8.00 12.00 16.00 20.00 16.00 12.00 8.00 4.31 123 1E12N055B 1/21/10 06-IC-1 E12-R-2002-05 Rosemount 1152GP7-N22 psig 0.00 57.40 119.90 182.40 244.90 182.40 119.90 57.40 0.00 124 1E12N055B 1/21/10 06-IC-1 E12-R-2002-05 Rosemount 1152GP7-N22 rnA 4.32 8.00 12.00 16.00 20.00 16.00 12.00 8.00 4.32 125 1E12N055B 5/29/08 06-IC-1 E12-R-2002-05 Rosemount 1152GP7-N22 psig 0.00 57.40 119.90 182.40 244.90 182.40 119.90 57.40 0.00 126 1E12N055B 5/29/08 06-IC-1 E12-R-2002-05 Rosemount 1152GP7-N22 rnA 4.32 8.00 12.00 16.00 20.00 16.00 12.00 8.00 4.32 127 1E12N055B 11/29/06 06-IC-1 E12-R-2002-05 Rosemount 1152GP7-N22 psig 0.00 57.40 119.90 182.40 244.90 182.40 119.90 57.40 0.00 128 1E12N055B 11/29/06 06-IC-1 E12-R-2002-05 Rosemount 1152GP7-N22 rnA 4.32 8.00 12.00 16.00 20.00 16.00 12.00 8.00 4.32 129 1E12N055B 5/20/05 06-IC-1 E12-R-2002-05 Rosemount 1152GP7-N22 psig 0.00 57.40 119.90 182.40 244.90 182.40 119.90 57.40 0.00 130 1E12N055B 5/20/05 06-IC-1 E12-R-2002-Q5 Rosemount 1152GP7-N22 rnA 4.32 8.00 12.00 16.00 20.00 16.00 12.00 8.00 4.32 131 1E12N055B 11/19/03 06-IC-1 E12-R-2002-05 Rosemount 1152GP7-N22 psig 0.00 57.40 119.90 182.40 244.90 182.40 119.90 57.40 0.00 132 1E12N055B 11/19/03 06-IC-1 E12-R-2002-05 Rosemount 1152GP7-N22 rnA 4.32 8.00 12.00 16.00 20.00 16.00 12.00 8.00 4.32

DRIFT ANALYSIS ENGINEERING DEPARTMENT GRAND GULF NUCLEAR STATION Rosemount Range Codes 5 - 8 Gage Pressure Transmitters Input Data JC-Q1111-09019 Rev. 0 Page 7 of 134 Instrument I Test Information Scaling Data Seq.

In lOut Pt1 Pt2 Pt 3 Pt4 Pt5 Pt6 Pt 7 Pta Pt9 10 Tag 10 Date Procedure-Attachment Make/Model Units (0% Up)

(25% Up)

(50% Up)

(75% Up)

(100% Up)

(75% On)

(50% On)

(25% On)

(0% On) 133 1E12N055B 6/4/02 06-IC-1E12-R-2002-Q5 Rosemount 1152GP7-N22 psig 0.00 57.40 119.90 182.40 244.90 182.40 119.90 57.40 0.00 134 1E12N055B 6/4/02 06-IC-1 E12-R-2002-05 Rosemount 1152GP7-N22 mA 4.32 8.00 12.00 16.00 20.00 16.00 12.00 8.00 4.32 135 1E12N055B 12/5/00 06-IC-1 E12-R-2002-Q5 Rosemount 1152GP7-N22 psig 0.00 57.40 119.90 182.40 244.90 182.40 119.90 57.40 0.00 136 1E12N055B 12/5/00 06-IC-1 E12-R-2002-05 Rosemount 1152GP7-N22 mA 4.32 8.00 12.00 16.00 20.00 16.00 12.00 8.00 4.32 137 1E12N055B 5/26/99 06-IC-1 E12-R-2002-05 Rosemount 1152GP7-N22 psig 0.00 57.40 119.90 182.40 244.90 182.40 119.90 57.40 0.00 138 1E12N055B 5/26/99 06-IC-1 E12-R-2002-Q5 Rosemount 1152GP7-N22 mA 4.32 8.00 12.00 16.00 20.00 16.00 12.00 8.00 4.32 139 1E12N055B 10/16/97 06-IC-1E12-R-2002-05 Rosemount 1152GP7-N22 psig 0.00 57.40 119.90 182.40 244.90 182.40 119.90 57.40 0.00 140 1E12N055B 10/16/97 06-IC-1 E12-R-2002-05 Rosemount 1152GP7-N22 mA 4.32 8.00 12.00 16.00 20.00 16.00 12.00 8.00 4.32

DRIFT ANALYSIS ENGINEERING DEPARTMENT GRAND GULF NUCLEAR STATION Rosemount Range Codes 5 - 8 Gage Pressure Transmitters Input Data JC-Q1111-09019 Rev. 0 Page 8 of 134 Instrument I Test Information Scaling Data Seq.

In lOut Pt 1 Pt2 Pt 3 Pt4 Pl5 Pt6 Pl7 Pt 8 Plg 10 Tag 10 Date Procedure-Attachment Make/Model Units (0% Up)

(25% Up)

(50% Up)

(75% Up)

(100% Up)

(75% On)

(50% On)

(25% On)

(0% On) 141 1E12N055C 1/20/10 06-IC-1E12-R-2002-06 Rosemount 1152GP7-N22 psig 0.00 61.80 124.30 186.80 249.30 186.80 124.30 61.80 0.00 142 1E12N055C 1/20/10 06-IC-1E12-R-2002-06 Rosemount 1152GP7-N22 rnA 4.05 8.00 12.00 16.00 20.00 16.00 12.00 8.00 4.05 143 1E12N055C 5/29/08 06-IC-1E12-R-2002-06 Rosemount 1152GP7-N22 psig 0.00 61.80 124.30 186.80 249.30 186.80 124.30 61.80 0.00 144 1E12N055C 5/29/08 06-IC-1E12-R-2002-06 Rosemount 1152GP7-N22 rnA 4.05 8.00 12.00 16.00 20.00 16.00 12.00 8.00 4.05 145 1E12N055C 11/29/06 06-IC-1 E12-R-2002-06 Rosemount 1152GP7-N22 psig 0.00 61.80 124.30 186.80 249.30 186.80 124.30 61.80 0.00 146 1E12N055C 11/29/06 06-1C-1 E12-R-2002.06 Rosemount 1152GP7-N22 rnA 4.05 8.00 12.00 16.00 20.00 16.00 12.00 8.00 4.05 147 1E12N055C 5/20/05 06-IC-1 E12-R-2002-06 Rosemount 1152GP7-N22 psig 0.00 61.80 124.30 186.80 249.30 186.80 124.30 61.80 0.00 148 1E12N055C 5/20/05 06-IC-1E12-R-2002-06 Rosemount 1152GP7-N22 mA 4.05 8.00 12.00 16.00 20.00 16.00 12.00 8.00 4.05 149 1E12N055C 11/19/03 06-IC-1 E12-R-2002.o6 Rosemount 1152GP7-N22 psig 0.00 61.80 124.30 186.80 249.30 186.80 124.30 61.80 0.00 150 1E12N055C 11/19/03 06-IC-1 E12-R-2002-06 Rosemount 1152GP7-N22 rnA 4.05 8.00 12.00 16.00 20.00 16.00 12.00 8.00 4.05 151 1E12N055C 7/3/02 06-IC-1E12-R-2002-06 Rosemount 1152GP7-N22 psig 0.00 61.80 124.30 186.80 249.30 186.80 124.30 61.80 0.00 152 1E12N055C 7/3/02 06-IC-1 E12-R-2002.o6 Rosemount 1152GP7-N22 mA 4.05 8.00 12.00 16.00 20.00 16.00 12.00 8.00 4.05 153 1E12N055C 12/6/00 06-IC-1 E12-R-2002.o6 Rosemount 1152GP7-N22 psig 0.00 61.80 124.30 186.80 249.30 186.80 124.30 61.80 0.00 154 1E12N055C 12/6/00 06-IC-1 E12-R-2002-06 Rosemount 1152GP7-N22 rnA 4.05 8.00 12.00 16.00 20.00 16.00 12.00 8.00 4.05 155 1E12N055C 5/27/99 06-IC-1 E12-R-2002-06 Rosemount 1152GP7-N22 psig 0.00 61.80 124.30 186.80 249.30 186.80 124.30 61.80 0.00 156 1E12N055C 5/27/99 06-IC-1 E12-R-2002-06 Rosemount 1152GP7-N22 mA 4.05 8.00 12.00 16.00 20.00 16.00 12.00 8.00 4.05 157 1E12N055C 10/16/97 06-IC-1E12-R-2002.o6 Rosemount 1152GP7-N22 psig 0.00 61.80 124.30 186.80 249.30 186.80 124.30 61.80 0.00 158 1E12N055C 10/16/97 06-IC-1E12-R-2002-06 Rosemount 1152GP7-N22 rnA 4.05 8.00 12.00 16.00 20.00 16.00 12.00 8.00 4.05 159 1E12N056A 12121/09 06-IC-1 E12-R-2002.o1 Rosemount 1152GP7-N22 psig 0.00 57.60 120.10 182.60 245.10 182.60 120.10 57.60 0.00 160 1E12N056A 12121/09 06-IC-1E12-R-2002-01 Rosemount 1152GP7-N22 mA 4.31 8.00 12.00 16.00 20.00 16.00 12.00 8.00 4.31

DRIFT ANALYSIS ENGINEERING DEPARTMENT GRAND GULF NUCLEAR STATION Rosemount Range Codes 5 - 8 Gage Pressure Transmitters Input Data JC-Q1111-09019 Rev. 0 Page 9 of 134 Instrument I Test Information Scaling Data Seq.

In / Out Pt1 Pt2 Pt3 Pt4 Pt5 Pt6 Pt7 PtS Pt9 10 Tag 10 Date Procedure-Attachment Make/Model Units (0% Up)

(25% Up)

(50% Up)

(75% Up)

(100% Up)

(75% On)

(50% On)

(25% On)

(0% On) 161 1E12N056A 6/30/08 06-IC-1 E12-R-2002-01 Rosemount 1152GP7-N22 psig 0.00 57.60 120.10 182.60 245.10 182.60 120.10 57.60 0.00 162 1E12N056A 6/30/08 06-IC-1 E12-R-2002-01 Rosemount 1152GP7-N22 mA 4.31 8.00 12.00 16.00 20.00 16.00 12.00 8.00 4.31 163 1E12N056A 9/15/06 06-IC-1 E12-R-2002-01 Rosemount 1152GP7-N22 psig 0.00 57.60 120.10 182.60 245.10 182.60 120.10 57.60 0.00 164 1E12N056A 9/15/06 06-IC-1 E12-R-2002-01 Rosemount 1152GP7-N22 mA 4.31 8.00 12.00 16.00 20.00 16.00 12.00 8.00 4.31 165 1E12N056A 1/17/05 06-IC-1 E12-R-2002-01 Rosemount 1152GP7-N22 psig 0.00 57.60 120.10 182.60 245.10 182.60 120.10 57.60 0.00 166 1E12N056A 1/17/05 06-IC-1 E12-R-2002-01 Rosemount 1152GP7-N22 mA 4.31 8.00 12.00 16.00 20.00 16.00 12.00 8.00 4.31 167 1E12N056A 8/6103 06-IC-1 E12-R-2002-01 Rosemount 1152GP7-N22 psig 0.00 57.60 120.10 182.60 245.10 182.60 120.10 57.60 0.00 168 1E12N056A 8/6/03 06-IC-1 E12-R-2002-01 Rosemount 1152GP7-N22 mA 4.31 8.00 12.00 16.00 20.00 16.00 12.00 8.00 4.31 169 1E12N056A 218/02 06-IC-1 E12-R-2002-Q1 Rosemount 1152GP7-N22 psig 0.00 57.60 120.10 182.60 245.10 182.60 120.10 57.60 0.00 170 1E12N056A 218/02 06-IC-1 E12-R-2002-Q1 Rosemount 1152GP7-N22 mA 4.31 8.00 12.00 16.00 20.00 16.00 12.00 8.00 4.31 171 1E12N056A 10/4/00 06-IC-1 E12-R-2002-01 Rosemount 1152GP7-N22 psig 0.00 57.60 120.10 182.60 245.10 182.60 120.10 57.60 0.00 172 1E12N056A 10/4/00 06-IC-1 E12-R-2002-01 Rosemount 1152GP7-N22 mA 4.31 8.00 12.00 16.00 20.00 16.00 12.00 8.00 4.31 173 1E12N056A 4/11/99 06-IC-1 E12-R-2002-01 Rosemount 1152GP7-N22 psig 0.00 57.60 120.10 182.60 245.10 182.60 120.10 57.60 0.00 174 1E12N056A 4/11/99 06-IC-1 E12-R-2002-01 Rosemount 1152GP7-N22 mA 4.31 8.00 12.00 16.00 20.00 16.00 12.00 8.00 4.31 175 1E12N056A 8/30/97 06-IC-1 E12-R-2002-01 Rosemount 1152GP7-N22 psig 0.00 57.60 120.10 182.60 245.10 182.60 120.10 57.60 0.00 176 1E12N056A 8/30/97 06-IC-1 E12-R-2002-01 Rosemount 1152GP7-N22 mA 4.31 8.00 12.00 16.00 20.00 16.00 12.00 8.00 4.31 177 1E12N0568 2/5/10 06-IC-1 E12-R-2002-02 Rosemount 1152GP7-N22 psig 0.00 57.40 119.90 182.40 244.90 182.40 119.90 57.40 0.00 178 1E12N0568 2/5/10 06-IC-1 E12-R-2002-02 Rosemount 1152GP7-N22 mA 4.32 8.00 12.00 16.00 20.00 16.00 12.00 8.00 4.32 179 1E12N0568 7/8/08 06-IC-1 E12-R-2002-02 Rosemount 1152GP7-N22 psig 0.00 57.40 119.90 182.40 244.90 182.40 119.90 57.40 0.00 180 1E12N0568 7/8/08 06-IC-1 E12-R-2002-02 Rosemount 1152GP7-N22 mA 4.32 8.00 12.00 16.00 20.00 16.00 12.00 8.00 4.32

DRIFT ANALYSIS ENGINEERING DEPARTMENT GRAND GULF NUCLEAR STATION Rosemount Range Codes 5 - 8 Gage Pressure Transmitters Input Data JC-Q1111-09019 Rev. 0 Page 10 of 134 Instrument I Test Information Scaling Data Seq.

In / Out Pt1 Pt2 Pt 3 Pt4 Pt5 Pt6 Pt7 Pt8 pt9 10 Tag 10 Date Procedure-Attachment Make/Model Units (0% Up)

(25% Up)

(50% Up)

(75% Up)

(100% Up)

(75% On)

(50% On)

(25% On)

(0% On) 181 1E12N056B 1/11/07 06-IC-1 E12-R-2002-02 Rosemount 1152GP7-N22 psig 0.00 57.40 119.90 182.40 244.90 182.40 119.90 57.40 0.00 182 1E12N056B 1/11/07 06-IC-1 E12-R-2002-Q2 Rosemount 1152GP7-N22 mA 4.32 8.00 12.00 16.00 20.00 16.00 12.00 8.00 4.32 183 1E12N056B 7/14/05 06-IC-1 E12-R-2002-02 Rosemount 1152GP7-N22 psig 0.00 57.40 119.90 182.40 244.90 182.40 119.90 57.40 0.00 184 1E12N056B 7/14/05 06-IC-1 E12-R-2002-02 Rosemount 1152GP7-N22 mA 4.32 8.00 12.00 16.00 20.00 16.00 12.00 8.00 4.32 185 1E12N056B 10/22103 06-IC-1 E12-R-2002-Q2 Rosemount 1152GP7-N22 psig 0.00 57.40 119.90 182.40 244.90 182.40 119.90 57.40 0.00 186 1E12N056B 10/22/03 06-IC-1 E12-R-2002-02 Rosemount 1152GP7-N22 mA 4.32 8.00 12.00 16.00 20.00 16.00 12.00 8.00 4.32 187 1E12N056B 4/23/02 06-IC-1 E12-R-2002-02 Rosemount 1152GP7-N22 psig 0.00 57.40 119.90 182.40 244.90 182.40 119.90 57.40 0.00 188 1E12N056B 4/23/02 06-IC-1 E12-R-2002-02 Rosemount 1152GP7-N22 mA 4.32 8.00 12.00 16.00 20.00 16.00 12.00 8.00 4.32 189 1E12N056B 1216/00 06-IC-1 E12-R-2002-Q2 Rosemount 1152GP7-N22 psig 0.00 57.40 119.90 182.40 244.90 182.40 119.90 57.40 0.00 190 1E12N056B 1216/00 06-IC-1E12-R-2002-02 Rosemount 1152GP7-N22 mA 4.32 8.00 12.00 16.00 20.00 16.00 12.00 8.00 4.32 191 1E12N056B 5/26/99 06-1C-1 E12-R-2002-02 Rosemount 1152GP7-N22 psig 0.00 57.40 119.90 182.40 244.90 182.40 119.90 57.40 0.00 192 1E12N056B 5/26/99 06-IC-1 E12-R-2002-02 Rosemount 1152GP7-N22 mA 4.32 8.00 12.00 16.00 20.00 16.00 12.00 8.00 4.32 193 1E12N056B 10/16/97 06-IC-1 E12-R-2002-02 Rosemount 1152GP7-N22 psig 0.00 57.40 119.90 182.40 244.90 182.40 119.90 57.40 0.00 194 1E12N056B 10/16/97 06-IC-1 E12-R-2002-02 Rosemount 1152GP7-N22 mA 4.32 8.00 12.00 16.00 20.00 16.00 12.00 8.00 4.32 195 1E12N056C 4/6/10 06-IC-1 E12-R-2002-03 Rosemount 1152GP7-N22 psig 0.00 61.80 124.30 186.80 249.30 186.80 124.30 61.80 0.00 196 1E12N056C 4/6/10 06-IC-1 E12-R-2002-03 Rosemount 1152GP7-N22 mA 4.05 8.00 12.00 16.00 20.00 16.00 12.00 8.00 4.05 197 1E12N056C 7/8/08 06-IC-1 E12-R-2002-03 Rosemount 1152GP7-N22 psig 0.00 61.80 124.30 186.80 249.30 186.80 124.30 61.80 0.00 198 1E12N056C 7/8/08 06-IC-1 E12-R-2002-03 Rosemount 1152GP7-N22 mA 4.05 8.00 12.00 16.00 20.00 16.00 12.00 8.00 4.05 199 1E12N056C 1/10107 06-IC-1 E12-R-2002-03 Rosemount 1152GP7-N22 psig 0.00 61.80 124.30 186.80 249.30 186.80 124.30 61.80 0.00 200 1E12N056C 1/10/07 06-IC-1 E12-R-2002-03 Rosemount 1152GP7-N22 rnA 4.05 8.00 12.00 16.00 20.00 16.00 12.00 8.00 4.05

DRIFT ANALYSIS ENGINEERING DEPARTMENT GRAND GULF NUCLEAR STATION Rosemount Range Codes 5 - 8 Gage Pressure Transmitters Input Data JC-Q1111-09019 Rev. 0 Page 11 of 134 Instrument I Test Information Scaling Data Seq.

In lOut pt1 Pt2 Pt 3 Pt4 pt5 pt6 pt7 PtB Pt9 10 Tag 10 Oate Procedure-Attachment Make IModel Units (0% Up)

(25% Up)

(50% Up)

(75% Up)

(100% Up)

(75% On)

(50% On)

(25% On)

(0% On) 201 1E12N056C 6/29/05 06-IC-1 E12-R-2002-03 Rosemount 1152GP7-N22 psig 0.00 61.80 124.30 186.80 249.30 186.80 124.30 61.80 0.00 202 1E12N056C 6/29/05 06-IC-1 E12-R-2002-03 Rosemount 1152GP7-N22 rnA 4.05 8.00 12.00 16.00 20.00 16.00 12.00 8.00 4.05 203 1E12N056C 10/22103 06-IC-1 E12-R-2002-Q3 Rosemount 1152GP7-N22 psig 0.00 61.80 124.30 186.80 249.30 186.80 124.30 61.80 0.00 204 1E12N056C 10/22/03 06-IC-1 E12-R-2002-Q3 Rosemount 1152GP7-N22 rnA 4.05 8.00 12.00 16.00 20.00 16.00 12.00 8.00 4.05 205 1E12N056C 7/3/02 06-IC-1 E12-R-2002-03 Rosemount 1152GP7-N22 psig 0.00 61.80 124.30 186.80 249.30 186.80 124.30 61.80 0.00 206 1E12N056C 7/3/02 06-IC-1E12-R-2002-03 Rosemount 1152GP7-N22 rnA 4.05 8.00 12.00 16.00 20.00 16.00 12.00 8.00 4.05 207 1E12N056C 12/6/00 06-IC-1 E12-R-2002-03 Rosemount 1152GP7-N22 psig 0.00 61.80 124.30 186.80 249.30 186.80 124.30 61.80 0.00 208 1E12N056C 12/6/00 06-IC-1 E12-R-2002-03 Rosemount 1152GP7-N22 rnA 4.05 8.00 12.00 16.00 20.00 16.00 12.00 8.00 4.05 209 1E12N056C 5/26/99 06-IC-1 E12-R-2002-03 Rosemount 1152GP7-N22 psig 0.00 61.80 124.30 186.80 249.30 186.80 124.30 61.80 0.00 210 1E12N056C 5/26/99 06-IC-1 E12-R-2002-03 Rosemount 1152GP7-N22 rnA 4.05 8.00 12.00 16.00 20.00 16.00 12.00 8.00 4.05 211 1E12N056C 10/16/97 06-IC-1 E12-R-2002-03 Rosemount 1152GP7-N22 psig 0.00 61.80 124.30 186.80 249.30 186.80 124.30 61.80 0.00 212 1E12N056C 10/16/97 06-IC-1 E12-R-2002-03 Rosemount 1152GP7-N22 rnA 4.05 8.00 12.00 16.00 20.00 16.00 12.00 8.00 4.05 213 1E12N057 2/9/10 06-IC-1 E12-R-1011-01 Rosemount 1151GP8A22 psig 4.00 129.00 254.00 379.00 504.00 379.00 254.00 129.00 4.00 214 1E12N057 2/9/10 06-IC-1 E12-R-1011-01 Rosemount 1151GP8A22 rnA 4.00 8.00 12.00 16.00 20.00 16.00 12.00 8.00 4.00 215 1E12N057 4/25/08 06-IC-1 E12-R-1011-01 Rosemount 1151GP8A22 psig 4.00 129.00 254.00 379.00 504.00 379.00 254.00 129.00 4.00 216 1E12N057 4/25/08 06-IC-1E12-R-1011-01 Rosemount 1151GP8A22 rnA 4.00 8.00 12.00 16.00 20.00 16.00 12.00 8.00 4.00 217 1E12N057 7/19/06 06-IC-1E12-R-1011-01 Rosemount 1151GP8A22 psig 4.00 129.00 254.00 379.00 504.00 379.00 254.00 129.00 4.00 218 1E12N057 7/19/06 06-IC-1 E12-R-1011-01 Rosemount 1151 GP8A22 rnA 4.00 8.00 12.00 16.00 20.00 16.00 12.00 8.00 4.00 219 1E12N057 1/20/05 06-IC-1 E12-R-1011-01 Rosemount 1151 GP8A22 psig 4.00 129.00 254.00 379.00 504.00 379.00 254.00 129.00 4.00 220 1E12N057 1/20/05 06-IC-1E12-R-1011-Q1 Rosemount 1151GP8A22 rnA 4.00 8.00 12.00 16.00 20.00 16.00 12.00 8.00 4.00 221 1E12N057 8/8/03 06-IC-1E12-R-1011-01 Rosemount 1151GP8A22 psig 4.00 129.00 254.00 379.00 504.00 379.00 254.00 129.00 4.00 222 1E12N057 8/8/03 06-IC-1E12-R-1011-01 Rosemount 1151 GP8A22 rnA 4.00 8.00 12.00 16.00 20.00 16.00 12.00 8.00 4.00

DRIFT ANALYSIS ENGINEERING DEPARTMENT GRAND GULF NUCLEAR STATION Rosemount Range Codes 5 - 8 Gage Pressure Transmitters Input Data JC-Q1111-09019 Rev. 0 Page 12 of 134 Instrument I Test Information Scaling Data Seq.

In lOut Pt1 Pt2 Pt 3 Pt4 Pt 5 Pt6 Pt7 PtS Pt9 10 Tag 10 Date Procedure-Attachment Make 1ModeI Units (0% Up)

(25% Up)

(50% Up)

(75% Up)

(100% Up)

(75% On)

(50% On)

(25% On)

(0% On) 223 1E12N057 2/20102 06-IC-1E12-R-1011-01 Rosemount 1151GP8A22 psig 4.00 129.00 254.00 379.00 504.00 379.00 254.00 129.00 4.00 224 1E12N057 2/20/02 06-IC-1 E12-R-1011-01 Rosemount 1151GP8A22 rnA 4.00 8.00 12.00 16.00 20.00 16.00 12.00 8.00 4.00 225 1E12N057 2/8/01 06-IC-1 E12-R-1011-Q1 Rosemount 1151 GP8A22 psig 4.00 129.00 254.00 379.00 504.00 379.00 254.00 129.00 4.00 226 1E12N057 2/8/01 06-IC-1 E12-R-1011-01 Rosemount 1151 GP8A22 mA 4.00 8.00 12.00 16.00 20.00 16.00 12.00 8.00 4.00 227 1E12N057 8/1/99 06-IC-1 E12-R-1011-01 Rosemount 1151GP8A22 psig 4.00 129.00 254.00 379.00 504.00 379.00 254.00 129.00 4.00 228 1E12N057 811/99 06-IC-1E12-R-1011-01 Rosemount 1151GP8A22 mA 4.00 8.00 12.00 16.00 20.00 16.00 12.00 8.00 4.00 229 1E12N057 1/27/98 06-IC-1E12-R-1011-01 Rosemount 1151GP8A22 psig 4.00 129.00 254.00 379.00 504.00 379.00 254.00 129.00 4.00 230 1E12N057 1/27/98 06-IC-1E12-R-1011-01 Rosemount 1151GP8A22 mA 4.00 8.00 12.00 16.00 20.00 16.00 12.00 8.00 4.00 231 1E12N058A 7/12/10 06-IC-1 E12-R-1 010-01 Rosemount 1151GP8A22 psig 1.50 176.50 351.50 526.50 701.50 526.50 351.50 176.50 1.50 232 1E12N058A 7/12/10 06-IC-1E12-R-1010-01 Rosemount 1151GP8A22 mA 4.00 8.00 12.00 16.00 20.00 16.00 12.00 8.00 4.00 233 1E12N058A 9/10/08 06-IC-1 E12-R-1 01 0-01 Rosemount 1151GP8A22 psig 1.50 176.50 351.50 526.50 701.50 526.50 351.50 176.50 1.50 234 1E12N058A 9/10/08 06-IC-1 E12-R-1 010-01 Rosemount 1151GP8A22 mA 4.00 8.00 12.00 16.00 20.00 16.00 12.00 8.00 4.00 235 1E12N058A 1/16/07 06-IC-1 E12-R-1010-01 Rosemount 1151GP8A22 psig 1.50 176.50 351.50 526.50 701.50 526.50 351.50 176.50 1.50 236 1E12N058A 1/16/07 06-IC-1 E12-R-1010-01 Rosemount 1151 GP8A22 mA 4.00 8.00 12.00 16.00 20.00 16.00 12.00 8.00 4.00 237 1E12N058A 7/22/05 06-IC-1 E12-R-1010-01 Rosemount 1151GP8A22 psig 1.50 176.50 351.50 526.50 701.50 526.50 351.50 176.50 1.50 238 1E12N058A 7/22/05 06-IC-1 E12-R-1010-01 Rosemount 1151 GP8A22 mA 4.00 8.00 12.00 16.00 20.00 16.00 12.00 8.00 4.00 239 1E12N058A 1/9/04 06-IC-1 E12-R-1010-Q1 Rosemount 1151 GP8A22 psig 1.50 176.50 351.50 526.50 701.50 526.50 351.50 176.50 1.50 240 1E12N058A 1/9/04 06-IC-1 E12-R-1 01 0-01 Rosemount 1151GP8A22 mA 4.00 8.00 12.00 16.00 20.00 16.00 12.00 8.00 4.00 241 1E12N058A 9/9/02 06-IC-1 E12-R-1010-01 Rosemount 1151GP8A22 psig 1.50 176.50 351.50 526.50 701.50 526.50 351.50 176.50 1.50 242 1E12N058A 9/9/02 06-IC-1 E12-R-1 01 0-01 Rosemount 1151GP8A22 mA 4.00 8.00 12.00 16.00 20.00 16.00 12.00 8.00 4.00 243 1E12N058A 1/23/01 06-IC-1 E12-R-1 01 0-01 Rosemount 1151GP8A22 psig 1.50 176.50 351.50 526.50 701.50 526.50 351.50 176.50 1.50

DRIFT ANALYSIS ENGINEERING DEPARTMENT GRAND GULF NUCLEAR STATION Rosemount Range Codes 5 - 8 Gage Pressure Transmitters Input Data JC-Q1111-09019 Rev. 0 Page 13 of 134 Instrument I Test Information Scaling Data Seq.

In lOut Pt 1 Pt2 Pt 3 Pt4 Pt5 Pt 6 Pt7 Pt8 Pt9 10 Tag 10 Date Procedure-Attachment Make IModel Units (0% Up)

(25% Up)

(50% Up)

(75% Up)

(100% Up)

(75% On)

(50% On)

(25% On)

(0% On) 244 1E12N058A 1/23/01 06-IC-1 E12-R-1010-01 Rosemount 1151GP8A22 rnA 4.00 8.00 12.00 16.00 20.00 16.00 12.00 8.00 4.00 245 1E12N058A 9/22199 06-IC-1 E12-R-1010-01 Rosemount 1151GP8A22 psig 1.50 176.50 351.50 526.50 701.50 526.50 351.50 176.50 1.50 246 1E12N058A 9/22/99 06-IC-1 E12-R-101 0-01 Rosemount 1151 GP8A22 rnA 4.00 8.00 12.00 16.00 20.00 16.00 12.00 8.00 4.00 247 1E12N058A 1/28/98 06-IC-1 E12-R-1010-01 Rosemount 1151GP8A22 psig 1.50 176.50 351.50 526.50 701.50 526.50 351.50 176.50 1.50 248 1E12N058A 1/28/98 06-IC-1 E12-R-1010-01 Rosemount 1151GP8A22 rnA 4.00 8.00 12.00 16.00 20.00 16.00 12.00 8.00 4.00 249 1E12N0588 2/19/10 06-IC-1 E12-R-1010-02 Rosemount 1151GP8A22 psig 0.00 175.00 350.00 525.00 700.00 525.00 350.00 175.00 0.00 250 1E12N0588 2119/10 06-IC-1 E12-R-1010-02 Rosemount 1151 GP8A22 rnA 4.00 8.00 12.00 16.00 20.00 16.00 12.00 8.00 4.00 251 1E12N0588 7/10108 06-IC-1 E12-R-1010-Q2 Rosemount 1151GP8A22 psig 0.00 175.00 350.00 525.00 700.00 525.00 350.00 175.00 0.00 252 1E12N0588 7110108 06-IC-1 E12-R-1 01 0-02 Rosemount 1151GP8A22 rnA 4.00 8.00 12.00 16.00 20.00 16.00 12.00 8.00 4.00 253 1E12N0588 1/10107 06-IC-1 E12-R-1010-02 Rosemount 1151 GP8A22 psig 0.00 175.00 350.00 525.00 700.00 525.00 350.00 175.00 0.00 254 1E12N0588 1/10107 06-IC-1E12-R-1010-02 Rosemount 1151 GP8A22 rnA 4.00 8.00 12.00 16.00 20.00 16.00 12.00 8.00 4.00 255 1E12N0588 6/29/05 06-IC-1 E12-R-1010-02 Rosemount 1151 GP8A22 psig 0.00 175.00 350.00 525.00 700.00 525.00 350.00 175.00 0.00 256 1E12N0588 6/29/05 06-IC-1 E12-R-101 0-02 Rosemount 1151GP8A22 rnA 4.00 8.00 12.00 16.00 20.00 16.00 12.00 8.00 4.00 257 1E12N0588 1/14/04 06-IC-1 E12-R-1010-02 Rosemount 1151 GP8A22 psig 0.00 175.00 350.00 525.00 700.00 525.00 350.00 175.00 0.00 258 1E12N0588 1/14/04 06-IC-1 E12-R-1010-02 Rosemount 1151 GP8A22 rnA 4.00 8.00 12.00 16.00 20.00 16.00 12.00 8.00 4.00 259 1E12N0588 7/18/02 06-IC-1 E12-R-1010-02 Rosemount 1151GP8A22 psig 0.00 175.00 350.00 525.00 700.00 525.00 350.00 175.00 0.00 260 1E12N0588 7/18/02 06-IC-1 E12-R-1010-Q2 Rosemount 1151GP8A22 rnA 4.00 8.00 12.00 16.00 20.00 16.00 12.00 8.00 4.00 261 1E12N0588 1/29/01 06-IC-1 E12-R-1010-02 Rosemount 1151 GP8A22 psig 0.00 175.00 350.00 525.00 700.00 525.00 350.00 175.00 0.00 262 1E12N0588 1/29/01 06-IC-1 E12-R-1010-02 Rosemount 1151 GP8A22 rnA 4.00 8.00 12.00 16.00 20.00 16.00 12.00 8.00 4.00 263 1E12N0588 8/19/99 06-IC-1 E12-R-1010-Q2 Rosemount 1151 GP8A22 psig 0.00 175.00 350.00 525.00 700.00 525.00 350.00 175.00 0.00 264 1E12N0588 8/19/99 06-IC-1 E12-R-1 01 0-02 Rosemount 1151GP8A22 rnA 4.00 8.00 12.00 16.00 20.00 16.00 12.00 8.00 4.00 265 1E12N0588 1/5/98 06-IC-1 E12-R-1010-02 Rosemount 1151GP8A22 psig 0.00 175.00 350.00 525.00 700.00 525.00 350.00 175.00 0.00

DRIFT ANALYSIS ENGINEERING DEPARTMENT GRAND GULF NUCLEAR STATION Rosemount Range Codes 5 - 8 Gage Pressure Transmitters Input Data JC-Q1111-09019 Rev. 0 Page 14 of 134 Instrument I Test Information Scaling Data Seq.

In lOut Pt1 Pt2 Pt3 Pt4 Pt5 Pt6 Pt7 Pt8 Ptg 10 Tag 10 Date Procedure-Attachment Make IModel Units (0% Up)

(25% Up)

(50% Up)

(75% Up)

(100% Up)

(75% On)

(50% On)

(25% On)

(0% Onl 266 1E12N058B 1/5/98 06-IC-1 E12-R-1010-02 Rosemount 1151GP8A22 mA 4.00 8.00 12.00 16.00 20.00 16.00 12.00 8.00 4.00 267 1E12N058C 2/16/10 06-IC-1 E12-R-1 010-03 Rosemount 1151GP8A22 psig 15.00 190.00 365.00 540.00 715.00 540.00 365.00 190.00 15.00 268 1E12N058C 2/16/10 06-IC-1 E12-R-1010-03 Rosemount 1151 GP8A22 rnA 4.01 8.01 12.01 16.01 20.01 16.01 12.01 8.01 4.01 269 1E12N058C 6/24/08 06-IC-1 E12-R-1010-03 Rosemount 1151 GP8A22 psig 15.00 190.00 365.00 540.00 715.00 540.00 365.00 190.00 15.00 270 1E12N058C 6/24/08 06-IC-1 E12-R-1010-03 Rosemount 1151GP8A22 mA 4.01 8.01 12.01 16.01 20.01 16.01 12.01 8.01 4.01 271 1E12N058C 12/2/06 06-IC-1 E12-R-1010-03 Rosemount 1151GP8A22 psig 15.00 190.00 365.00 540.00 715.00 540.00 365.00 190.00 15.00 272 1E12N058C 12/2/06 06-IC-1 E12-R-101 0-03 Rosemount 1151GP8A22 rnA 4.01 8.01 12.01 16.01 20.01 16.01 12.01 8.01 4.01 273 1E12N058C 5/19/05 06-IC-1 E12-R-1010-03 Rosemount 1151GP8A22 psig 15.00 190.00 365.00 540.00 715.00 540.00 365.00 190.00 15.00 274 1E12N058C 5/19/05 06-IC-1 E12-R-1010-03 Rosemount 1151GP8A22 mA 4.01 8.01 12.01 16.01 20.01 16.01 12.01 8.01 4.01 275 1E12N058C 10/23/03 06-IC-1 E12-R-1010-03 Rosemount 1151GP8A22 psig 15.00 190.00 365.00 540.00 715.00 540.00 365.00 190.00 15.00 276 1E12N058C 10/23/03 06-IC-1 E12-R-1010-03 Rosemount 1151GP8A22 mA 4.01 8.01 12.01 16.01 20.01 16.01 12.01 8.01 4.01 277 1E12N058C 7/18/02 06-IC-1 E12-R-1010-03 Rosemount 1151GP8A22 psig 15.00 190.00 365.00 540.00 715.00 540.00 365.00 190.00 15.00 278 1E12N058C 7/18/02 06-IC-1 E12-R-1010-03 Rosemount 1151GP8A22 rnA 4.01 8.01 12.01 16.01 20.01 16.01 12.01 8.01 4.01 279 1E12N058C 1/29/01 06-IC-1 E12-R-1010-03 Rosemount 1151GP8A22 psig 15.00 190.00 365.00 540.00 715.00 540.00 365.00 190.00 15.00 280 1E12N058C 1/29/01 06-IC-1 E12-R-1010-03 Rosemount 1151GP8A22 rnA 4.01 8.01 12.01 16.01 20.01 16.01 12.01 8.01 4.01 281 1E12N058C 9/2/99 06-IC-1 E12-R-101 0-03 Rosemount 1151 GP8A22 psig 15.00 190.00 365.00 540.00 715.00 540.00 365.00 190.00 15.00 282 1E12N058C 9/2/99 06-IC-1 E12-R-1010-Q3 Rosemount 1151GP8A22 mA 4.01 8.01 12.01 16.01 20.01 16.01 12.01 8.01 4.01 283 1E12N058C 2/21/98 06-IC-1 E12-R-1010-03 Rosemount 1151GP8A22 psig 15.00 190.00 365.00 540.00 715.00 540.00 365.00 190.00 15.00 284 1E12N058C 2/21/98 06-IC-1 E12-R-1010-Q3 Rosemount 1151GP8A22 rnA 4.01 8.01 12.01 16.01 20.01 16.01 12.01 8.01 4.01 285 1E21N050 8/27/10 06-1C-1 E21-R-0004-01 Rosemount 1151GP8D22 psig 15.00 190.00 365.00 540.00 715.00 540.00 365.00 190.00 15.00 286 1E21N050 8/27/10 06-IC-1 E21-R-0004-01 Rosemount 1151GP8D22 mA 4.00 8.00 12.00 16.00 20.00 16.00 12.00 8.00 4.00 287 1E21N050 11/20/08 06-IC-1E21-R-0004-01 Rosemount 1151GP8D22 psig 15.00 190.00 365.00 540.00 715.00 540.00 365.00 190.00 15.00

DRIFT ANALYSIS ENGINEERING DEPARTMENT GRAND GULF NUCLEAR STATION Rosemount Range Codes 5 - 8 Gage Pressure Transmitters Input Data JC-Q1111-09019 Rev. 0 Page 15 of 134 Instrument I Test Information Scaling Data Seq.

In / Out Pt1 Pt2 Pt3 Pt4 Pt5 Pt6 Pt7 Pt8 Pt9 10 Tag 10 Date Procedure-Attachment Make/Model Units (0% Up)

(25% Up)

(50% Up)

(75% Up)

(100% Up)

(75% On)

(50% On)

(25% On)

(0% On) 288 1E21N050 11/20/08 06-IC-1 E21-R-0004-01 Rosemount 1151GP8D22 rnA 4.00 8.00 12.00 16.00 20.00 16.00 12.00 8.00 4.00 289 1E21N050 5/11/07 06-IC-1E21-R-0004-01 Rosemount 1151GP8D22 psig 15.00 190.00 365.00 540.00 715.00 540.00 365.00 190.00 15.00 290 1E21N050 5/11/07 06-IC-1 E21-R-0004-01 Rosemount 1151GP8D22 rnA 4.00 8.00 12.00 16.00 20.00 16.00 12.00 8.00 4.00 291 1E21N050 7/18/05 06-IC-1 E21-R-0004-01 Rosemount 1151GP8D22 psig 15.00 190.00 365.00 540.00 715.00 540.00 365.00 190.00 15.00 292 1E21N050 7/18/05 06-IC-1 E21-R-0004-01 Rosemount 1151GP8D22 rnA 4.00 8.00 12.00 16.00 20.00 16.00 12.00 8.00 4.00 293 1E21N050 10/14/03 06-1C-1 E21-R-0004-01 Rosemount 1151GP8D22 psig 15.00 190.00 365.00 540.00 715.00 540.00 365.00 190.00 15.00 294 1E21N050 10/14/03 06-IC-1 E21-R-0004-01 Rosemount 1151GP8D22 rnA 4.00 8.00 12.00 16.00 20.00 16.00 12.00 8.00 4.00 295 1E21N050 4/18/02 06-IC-1 E21-R-0004-01 Rosemount 1151GP8D22 psig 15.00 190.00 365.00 540.00 715.00 540.00 365.00 190.00 15.00 296 1E21N050 4/18/02 06-1C-1 E21-R-0004-01 Rosemount 1151GP8D22 rnA 4.00 8.00 12.00 16.00 20.00 16.00 12.00 8.00 4.00 297 1E21N050 10/16/00 06-IC-1E21-R-0004-01 Rosemount 1151 GP8D22 psig 15.00 190.00 365.00 540.00 715.00 540.00 365.00 190.00 15.00 298 1E21N050 10/16/00 06-IC-1 E21-R-0004-01 Rosemount 1151GP8D22 rnA 4.00 8.00 12.00 16.00 20.00 16.00 12.00 8.00 4.00 299 1E21N050 4/11/99 06-IC-1 E21-R-0004-01 Rosemount 1151GP8D22 psig 15.00 190.00 365.00 540.00 715.00 540.00 365.00 190.00 15.00 300 1E21N050 4/11/99 06-IC-1 E21-R-0004-D1 Rosemount 1151GP8D22 rnA 4.00 8.00 12.00 16.00 20.00 16.00 12.00 8.00 4.00 301 1E21N050 8/30/97 06-IC-1 E21-R-0004-01 Rosemount 1151GP8D22 psig 15.00 190.00 365.00 540.00 715.00 540.00 365.00 190.00 15.00 302 1E21N050 8/30/97 06-IC-1 E21-R-0004-01 Rosemount 1151 GP8D22 rnA 4.00 8.00 12.00 16.00 20.00 16.00 12.00 8.00 4.00 303 1E21N052 2/8/10 06-IC-1 E21-R-2002-01 Rosemount 1152GP7E22 psig 0.00 61.70 124.20 186.70 249.20 186.70 124.20 61.70 0.00 304 1E21N052 2/8/10 06-IC-1 E21-R-2002-01 Rosemount 1152GP7E22 rnA 4.05 8.00 12.00 16.00 20.00 16.00 12.00 8.00 4.05 305 1E21N052 5/22108 06-IC-1 E21-R-2002-01 Rosemount 1152GP7E22 psig 0.00 61.70 124.20 186.70 249.20 186.70 124.20 61.70 0.00 306 1E21N052 5/22/08 06-IC-1 E21-R-2002-D1 Rosemount 1152GP7E22 rnA 4.05 8.00 12.00 16.00 20.00 16.00 12.00 8.00 4.05 307 1E21N052 11/10/06 06-IC-1 E21-R-2002-01 Rosemount 1152GP7E22 psig 0.00 61.70 124.20 186.70 249.20 186.70 124.20 61.70 0.00 308 1E21N052 11/10/06 06-IC-1 E21-R-2002-01 Rosemount 1152GP7E22 rnA 4.05 8.00 12.00 16.00 20.00 16.00 12.00 8.00 4.05 309 1E21N052 4/12/05 06-IC-1 E21-R-2002-01 Rosemount 1152GP7E22 psig 0.00 61.70 124.20 186.70 249.20 186.70 124.20 61.70 0.00

DRIFT ANALYSIS ENGINEERING DEPARTMENT GRAND GULF NUCLEAR STATION Rosemount Range Codes 5 - 8 Gage Pressure Transmitters Input Data JC-Q1111-09019 Rev. 0 Page 16 of 134 Instrument I Test Information Scaling Data Seq.

In / Out Pt1 Pt2 Pt3 Pt4 Pt5 Pt6 Pt 7 PtS Ptg 10 Tag 10 Date Procedure-Attachment Make/Model Units (0% Up)

(25% Up)

(50% Up)

(75% Up)

(100% Up)

(75% On)

(50% On)

(25% On)

(0% On) 310 1E21N052 4/12/05 06-IC-1 E21-R-2002-01 Rosemount 1152GP7E22 mA 4.05 8.00 12.00 16.00 20.00 16.00 12.00 8.00 4.05 311 1E21N052 6/25/03 06-IC-1 E21-R-2002-Q1 Rosemount 1152GP7E22 psig 0.00 61.70 124.20 186.70 249.20 186.70 124.20 61.70 0.00 312 1E21N052 6/25/03 06-IC-1 E21-R-2002-01 Rosemount 1152GP7E22 mA 4.05 8.00 12.00 16.00 20.00 16.00 12.00 8.00 4.05 313 1E21N052 1/9/02 06-IC-1E21-R-2002-01 Rosemount 1152GP7E22 psig 0.00 61.70 124.20 186.70 249.20 186.70 124.20 61.70 0.00 314 1E21N052 1/9/02 06-IC-1 E21-R-2002-01 Rosemount 1152GP7E22 mA 4.05 8.00 12.00 16.00 20.00 16.00 12.00 8.00 4.05 315 1E21N052 9/10/00 06-IC-1 E21-R-2002-01 Rosemount 1152GP7E22 psig 0.00 61.70 124.20 186.70 249.20 186.70 124.20 61.70 0.00 316 1E21N052 9/10/00 06-IC-1 E21-R-2002-01 Rosemount 1152GP7E22 mA 4.05 8.00 12.00 16.00 20.00 16.00 12.00 8.00 4.05 317 1E21N052 3/10/99 06-IC-1 E21-R-2002-01 Rosemount 1152GP7E22 psig 0.00 61.70 124.20 186.70 249.20 186.70 124.20 61.70 0.00 318 1E21N052 3/10/99 06-IC-1 E21-R-2002-01 Rosemount 1152GP7E22 rnA 4.05 8.00 12.00 16.00 20.00 16.00 12.00 8.00 4.05 319 1E21N052 8/25/97 06-IC-1 E21-R-2002-Q1 Rosemount 1152GP7E22 psig 0.00 61.70 124.20 186.70 249.20 186.70 124.20 61.70 0.00 320 1E21N052 8/25/97 06-IC-1 E21-R-2002-01 Rosemount 1152GP7E22 mA 4.05 8.00 12.00 16.00 20.00 16.00 12.00 8.00 4.05 321 1E21N053 8/10/09 06-IC-1 E21-R-2002-02 Rosemount 1152GP7E22 psig 0.00 61.70 124.20 186.70 249.20 186.70 124.20 61.70 0.00 322 1E21N053 8/10/09 06-IC-1 E21-R-2002-Q2 Rosemount 1152GP7E22 rnA 4.05 8.00 12.00 16.00 20.00 16.00 12.00 8.00 4.05 323 1E21N053 2/14/08 06-IC-1 E21-R-2002-02 Rosemount 1152GP7E22 psig 0.00 61.70 124.20 186.70 249.20 186.70 124.20 61.70 0.00 324 1E21N053 2/14/08 06-IC-1 E21-R-2002-02 Rosemount 1152GP7E22 mA 4.05 8.00 12.00 16.00 20.00 16.00 12.00 8.00 4.05 325 1E21N053 8/15/06 06-IC-1 E21-R-2002-02 Rosemount 1152GP7E22 psig 0.00 61.70 124.20 186.70 249.20 186.70 124.20 61.70 0.00 326 1E21N053 8/15/06 06-IC-1 E21-R-2002-02 Rosemount 1152GP7E22 mA 4.05 8.00 12.00 16.00 20.00 16.00 12.00 8.00 4.05 327 1E21N053 1/22105 06-IC-1 E21-R-2002-02 Rosemount 1152GP7E22 psig 0.00 61.70 124.20 186.70 249.20 186.70 124.20 61.70 0.00 328 1E21N053 1/22/05 06-IC-1 E21-R-2002-02 Rosemount 1152GP7E22 mA 4.05 8.00 12.00 16.00 20.00 16.00 12.00 8.00 4.05 329 1E21N053 7/22103 06-IC-1 E21-R-2002-02 Rosemount 1152GP7E22 psig 0.00 61.70 124.20 186.70 249.20 186.70 124.20 61.70 0.00 330 1E21N053 7/22/03 06-IC-1 E21-R-2002-02 Rosemount 1152GP7E22 mA 4.05 8.00 12.00 16.00 20.00 16.00 12.00 8.00 4.05 331 1E21N053 1/10/02 06-IC-1 E21-R-2002-02 Rosemount 1152GP7E22 psig 0.00 61.70 124.20 186.70 249.20 186.70 124.20 61.70 0.00

DRIFT ANALYSIS ENGINEERING DEPARTMENT GRAND GULF NUCLEAR STATION Rosemount Range Codes 5 - 8 Gage Pressure Transmitters Input Data JC-Q1111-09019 Rev. 0 Page 17 of 134 Instrument I Test Information Scaling Data Seq.

In lOut Pt 1 Pt2 Pt3 Pt4 Pt5 Pt6 Pt7 pta Pt9 10 Tag 10 Date Procedure-Attachment Make/Model Units (0% Up)

(25% Up)

(50% Up)

(75% Up)

(100% Up)

(75% On)

(50% On)

(25% On)

(0% On) 332 1E21N053 1/10/02 06-IC-1 E21-R-2002-02 Rosemount 1152GP7E22 rnA 4.05 8.00 12.00 16.00 20.00 16.00 12.00 8.00 4.05 333 1E21N053 9/10/00 06-IC-1 E21-R-2002-02 Rosemount 1152GP7E22 psig 0.00 61.70 124.20 186.70 249.20 186.70 124.20 61.70 0.00 334 1E21N053 9/10/00 06-IC-1 E21-R-2002-Q2 Rosemount 1152GP7E22 rnA 4.05 8.00 12.00 16.00 20.00 16.00 12.00 8.00 4.05 335 1E21N053 3/11/99 06-IC-1 E21-R-2002-02 Rosemount 1152GP7E22 psig 0.00 61.70 124.20 186.70 249.20 186.70 124.20 61.70 0.00 336 1E21N053 3/11/99 06-IC-1 E21-R-2002-02 Rosemount 1152GP7E22 rnA 4.05 8.00 12.00 16.00 20.00 16.00 12.00 8.00 4.05 337 1E21N053 8/25/97 06-IC-1E21-R-2002-02 Rosemount 1152GP7E22 psig 0.00 61.70 124.20 186.70 249.20 186.70 124.20 61.70 0.00 338 1E21N053 8/25/97 06-IC-1 E21-R-2002-02 Rosemount 1152GP7E22 rnA 4.05 8.00 12.00 16.00 20.00 16.00 12.00 8.00 4.05 339 1E21N054 9/24/10 06-IC-1 E21-R-0001-01 Rosemount 1151 GP8A22 psig 0.00 174.00 349.00 524.00 699.00 524.00 349.00 174.00 0.00 340 1E21N054 9/24/10 06-IC-1 E21-R-0001-01 Rosemount 1151 GP8A22 rnA 4.02 8.00 12.00 16.00 20.00 16.00 12.00 8.00 4.02 341 1E21N054 11/20/08 06-IC-1 E21-R-0001-01 Rosemount 1151GP8A22 psig 0.00 174.00 349.00 524.00 699.00 524.00 349.00 174.00 0.00 342 1E21N054 11/20/08 06-IC-1E21-R-0001-01 Rosemount 1151 GP8A22 rnA 4.02 8.00 12.00 16.00 20.00 16.00 12.00 8.00 4.02 343 1E21N054 5/7/07 06-IC-1 E21-R-0001-01 Rosemount 1151 GP8A22 psig 0.00 174.00 349.00 524.00 699.00 524.00 349.00 174.00 0.00 344 1E21N054 5/7/07 06-IC-1 E21-R-0001-01 Rosemount 1151 GP8A22 mA 4.02 8.00 12.00 16.00 20.00 16.00 12.00 8.00 4.02 345 1E21N054 811105 06-IC-1 E21-R-0001-Q1 Rosemount 1151GP8A22 psig 0.00 174.00 349.00 524.00 699.00 524.00 349.00 174.00 0.00 346 1E21N054 811105 06-IC-1 E21-R-0001-01 Rosemount 1151 GP8A22 mA 4.02 8.00 12.00 16.00 20.00 16.00 12.00 8.00 4.02 347 1E21N054 12/9/03 06-IC-1 E21-R-0001-01 Rosemount 1151 GP8A22 psig 0.00 174.00 349.00 524.00 699.00 524.00 349.00 174.00 0.00 348 1E21N054 12/9/03 06-IC-1 E21-R-0001-Q1 Rosemount 1151GP8A22 rnA 4.02 8.00 12.00 16.00 20.00 16.00 12.00 8.00 4.02 349 1E21N054 7/11/02 06-IC-1E21-R-0001-01 Rosemount 1151 GP8A22 psig 0.00 174.00 349.00 524.00 699.00 524.00 349.00 174.00 0.00 350 1E21N054 7/11/02 06-IC-1E21-R-0001-Q1 Rosemount 1151GP8A22 mA 4.02 8.00 12.00 16.00 20.00 16.00 12.00 8.00 4.02 351 1E21N054 1/23/01 06-IC-1 E21-R-0001-01 Rosemount 1151GP8A22 psig 0.00 174.00 349.00 524.00 699.00 524.00 349.00 174.00 0.00 352 1E21N054 1/23/01 06-IC-1 E21-R-0001-01 Rosemount 1151 GP8A22 rnA 4.02 8.00 12.00 16.00 20.00 16.00 12.00 8.00 4.02 353 1E21N054 7/12/99 06-IC-1 E21-R-0001-01 Rosemount 1151GP8A22 psig 0.00 174.00 349.00 524.00 699.00 524.00 349.00 174.00 0.00

DRIFT ANALYSIS ENGINEERING DEPARTMENT GRAND GULF NUCLEAR STATION Rosemount Range Codes 5 - 8 Gage Pressure Transmitters Input Data JC-Q1111-09019 Rev. 0 Page 18 of 134 Instrument I Test Information Scaling Data Seq.

In / Out Pt 1 Pt2 Pt3 Pt4 PtS Pt6 Pt7 PtS Pt9 10 Tag 10 Date Procedure-Attachment Make/Model Units (0% Up)

(2S%Up)

(SO%Up)

(7S%Up)

(100% Up)

(7S% On)

(SO%On)

(2S% On)

(0% On) 354 1E21N054 7/12/99 06-IC-1 E21-R-0001-01 Rosemount 1151GP8A22 mA 4.02 8.00 12.00 16.00 20.00 16.00 12.00 8.00 4.02 355 1E21N054 1/15/98 06-IC-1 E21-R-0001-01 Rosemount 1151GP8A22 psig 0.00 174.00 349.00 524.00 699.00 524.00 349.00 174.00 0.00 356 1E21N054 1/15/98 06-IC-1 E21-R-0001-01 Rosemount 1151 GP8A22 mA 4.02 8.00 12.00 16.00 20.00 16.00 12.00 8.00 4.02 357 1E22N050 3/19/10 06-IC-1 E22-R-0001-Q1 Rosemount 1152GP6E22 psig 0.00 7.00 19.00 32.00 44.00 32.00 19.00 7.00 0.00 358 1E22N050 3/19110 06-IC-1 E22-R-0001-01 Rosemount 1152GP6E22 mA 5.88 8.12 11.96 16.12 19.96 16.12 11.96 8.12 5.88 359 1E22N050 6/27/08 06-IC-1 E22-R-0001-1 Rosemount 1152GP6E22 psig 0.00 7.00 19.00 32.00 44.00 32.00 19.00 7.00 0.00 360 1E22N050 6/27/08 06-IC-1E22-R-0001-1 Rosemount 1152GP6E22 mA 5.88 8.12 11.96 16.12 19.96 16.12 11.96 8.12 5.88 361 1E22N050 11/15/06 06-IC-1E22-R-0001-1 Rosemount 1152GP6E22 psig 0.00 7.00 19.00 32.00 44.00 32.00 19.00 7.00 0.00 362 1E22N050 11/15/06 06-IC-1E22-R-0001-1 Rosemount 1152GP6E22 rnA 5.88 8.12 11.96 16.12 19.96 16.12 11.96 8.12 5.88 363 1E22N050 6/3/05 06-IC-1E22-R-0001-1 Rosemount 1152GP6E22 psig 0.00 7.00 19.00 32.00 44.00 32.00 19.00 7.00 0.00 364 1E22N050 6/3/05 06-IC-1 E22-R-0001-1 Rosemount 1152GP6E22 mA 5.88 8.12 11.96 16.12 19.96 16.12 11.96 8.12 5.88 365 1E22N050 9/26/03 06-IC-1E22-R-0001-1 Rosemount 1152GP6E22 psig 0.00 7.00 19.00 32.00 44.00 32.00 19.00 7.00 0.00 366 1E22N050 9/26/03 06-IC-1 E22-R-0001-1 Rosemount 1152GP6E22 mA 5.88 8.12 11.96 16.12 19.96 16.12 11.96 8.12 5.88 367 1E22N050 4/12/02 06-IC-1E22-R-0001-1 Rosemount 1152GP6E22 psig 0.00 7.00 19.00 32.00 44.00 32.00 19.00 7.00 0.00

DRIFT ANALYSIS ENGINEERING DEPARTMENT GRAND GULF NUCLEAR STATION Rosemount Range Codes 5 - 8 Gage Pressure Transmitters Input Data JC-Q1111-09019 Rev. 0 Page 19 of 134 Instrument I Test Information Scaling Data Seq.

In / Out Pt1 Pt2 Pt3 Pt4 Pt5 Pt6 Pt7 Pt8 Pt9 10 Tag 10 Date Procedure-Attachment Make/Model Units (0% Up)

(25% Up)

(50% Up)

(75% Up)

(100% Up)

(75% On)

(50% On)

(25% On)

(0% On) 368 1E22N050 4/12/02 06-IC-1 E22-R-0001-1 Rosemount 1152GP6E22 rnA 5.88 8.12 11.96 16.12 19.96 16.12 11.96 8.12 5.88 369 1E22N050 11/24/00 06-IC-1E22-R-0001-1 Rosemount 1152GP6E22 psig 0.00 7.00 19.00 32.00 44.00 32.00 19.00 7.00 0.00 370 1E22N050 11/24/00 06-IC-1E22-R-0001-1 Rosemount 1152GP6E22 rnA 5.88 8.12 11.96 16.12 19.96 16.12 11.96 8.12 5.88 371 1E22N050 412199 06-IC-1 E22-R-0001-1 Rosemount 1152GP6E22 psig 0.00 7.00 19.00 32.00 44.00 32.00 19.00 7.00 0.00 372 1E22N050 4/2/99 06-IC-1 E22-R-OOO1-1 Rosemount 1152GP6E22 rnA 5.88 8.12 11.96 16.12 19.96 16.12 11.96 8.12 5.88 373 1E22N050 9/5/97 06-IC-1E22-R-0001-1 Rosemount 1152GP6E22 psig 0.00 7.00 19.00 32.00 44.00 32.00 19.00 7.00 0.00 374 1E22N050 9/5/97 06-IC-1E22-R-0001-1 Rosemount 1152GP6E22 rnA 5.88 8.12 11.96 16.12 19.96 16.12 11.96 8.12 5.88 375 1E22N054C 4/2/10 06-IC-1 E22-R-0002-01 Rosemount 1153GB5RA InWC 15.00 130.00 250.00 370.00 490.00 370.00 250.00 130.00 15.00 376 1E22N054C 412110 06-IC-1 E22-R-0002-01 Rosemount 1153GB5RA rnA 4.06 7.91 11.93 15.95 19.97 15.95 11.93 7.91 4.06 377 1E22N054C 5/30108 06-IC-1 E22-R-0002-01 Rosemount 1153GB5RA inWC 15.00 130.00 250.00 370.00 490.00 370.00 250.00 130.00 15.00 378 1E22N054C 5/30108 06-IC-1E22-R-0002-Q1 Rosemount 1153GB5RA rnA 4.06 7.91 11.93 15.95 19.97 15.95 11.93 7.91 4.06 379 1E22N054C 1/12/07 06-IC-1 E22-R-0002-01 Rosemount 1153GB5RA inWC 15.00 130.00 250.00 370.00 490.00 370.00 250.00 130.00 15.00 380 1E22N054C 1/12/07 06-IC-1 E22-R-0002-01 Rosemount 1153GB5RA rnA 4.06 7.91 11.93 15.95 19.97 15.95 11.93 7.91 4.06 381 1E22N054G 11/20109 06-IC-1 E22-R-0002-Q2 Rosemount 1153GB5RA InWC 15.00 130.00 250.00 370.00 490.00 370.00 250.00 130.00 15.00 382 1E22N054G 11/20/09 06-1C-1 E22-R-0002-02 Rosemount 1153GB5RA rnA 4.06 7.91 11.93 15.95 19.97 15.95 11.93 7.91 4.06 383 1E22N054G 5/30108 06-IC-1 E22-R-0002-02 Rosemount 1153GB5RA inWC 15.00 130.00 250.00 370.00 490.00 370.00 250.00 130.00 15.00 384 1E22N054G 5/30/08 06-IC-1 E22-R-0002-02 Rosemount 1153GB5RA rnA 4.06 7.91 11.93 15.95 19.97 15.95 11.93 7.91 4.06

DRIFT ANALYSIS ENGINEERING DEPARTMENT GRAND GULF NUCLEAR STATION Rosemount Range Codes 5 - 8 Gage Pressure Transmitters Input Data JC-Q1111-09019 Rev. 0 Page 20 of 134 Instrument I Test Information Scaling Data Seq.

In / Out Pt 1 Pt2 Pt 3 Pt4 Pt5 Pt6 Pt 7 Pt 8 Pt9 10 Tag 10 Date Procedure-Attachment Make/Model Units (0% Up)

(25% Up)

(50% Up)

(75% Up)

(100% Up)

(75% On)

(50% On)

(25% On)

(0% On) 385 1E22N054G 10/20/06 06-IC-1 E22-R-0002-Q2 Rosemount 1153GB5RA inWC 15.00 130.00 250.00 370.00 490.00 370.00 250.00 130.00 15.00 386 1E22N054G 10/20/06 06-IC-1 E22-R-0002-02 Rosemount 1153GB5RA mA 4.06 7.91 11.93 15.95 19.97 15.95 11.93 7.91 4.06 387 1E31N085A 5/12/10 06-IC-1 E31-R-1016-Q1 Rosemount 1152GP7-N22 psig 2.10 52.10 102.10 152.10 202.10 152.10 102.10 52.10 2.10 388 1E31N085A 5/12/10 06-IC-1 E31-R-1 016-Q1 Rosemount 1152GP7-N22 mA 4.00 8.00 12.00 16.00 20.00 16.00 12.00 8.00 4.00 389 1E31N085A 9/30/08 06-IC-1 E31-R-1016-01 Rosemount 1152GP7-N22 psig 2.10 52.10 102.10 152.10 202.10 152.10 102.10 52.10 2.10 390 1E31N085A 9/30/08 06-IC-1 E31-R-1 016-01 Rosemount 1152GP7-N22 mA 4.00 8.00 12.00 16.00 20.00 16.00 12.00 8.00 4.00 391 1E31N085A 4/2/07 06-IC-1 E31-R-1 016-01 Rosemount 1152GP7-N22 psig 2.10 52.10 102.10 152.10 202.10 152.10 102.10 52.10 2.10 392 1E31N085A 4/2107 06-IC-1 E31-R-1016-Q1 Rosemount 1152GP7-N22 mA 4.00 8.00 12.00 16.00 20.00 16.00 12.00 8.00 4.00 393 1E31N085A 9/28/05 06-IC-1 E31-R-1016-01 Rosemount 1152GP7-N22 psig 2.10 52.10 102.10 152.10 202.10 152.10 102.10 52.10 2.10 394 1E31N085A 9/28/05 06-IC-1 E31-R-1016-01 Rosemount 1152GP7-N22 mA 4.00 8.00 12.00 16.00 20.00 16.00 12.00 8.00 4.00 395 1E31N085A 3/5/04 06-IC-1 E31-R-1 016-01 Rosemount 1152GP7-N22 psig 2.10 52.10 102.10 152.10 202.10 152.10 102.10 52.10 2.10 396 1E31N085A 3/5/04 06-IC-1 E31-R-1016-01 Rosemount 1152GP7-N22 mA 4.00 8.00 12.00 16.00 20.00 16.00 12.00 8.00 4.00 397 1E31N085A 9/23/02 06-IC-1 E31-R-1016-01 Rosemount 1152GP7-N22 psig 2.10 52.10 102.10 152.10 202.10 152.10 102.10 52.10 2.10 398 1E31N085A 9/23/02 06-IC-1 E31-R-1016-01 Rosemount 1152GP7-N22 mA 4.00 8.00 12.00 16.00 20.00 16.00 12.00 8.00 4.00 399 1E31N085A 4/24/01 06-IC-1 E31-R-1016-01 Rosemount 1152GP7-N22 psig 2.10 52.10 102.10 152.10 202.10 152.10 102.10 52.10 2.10 400 1E31N085A 4/24/01 06-IC-1 E31-R-1 016-01 Rosemount 1152GP7-N22 mA 4.00 8.00 12.00 16.00 20.00 16.00 12.00 8.00 4.00 401 1E31N085A 11/4/99 06-IC-1 E31-R-1016-01 Rosemount 1152GP7-N22 psig 2.10 52.10 102.10 152.10 202.10 152.10 102.10 52.10 2.10 402 1E31N085A 11/4/99 06-IC-1 E31-R-1016-01 Rosemount 1152GP7-N22 mA 4.00 8.00 12.00 16.00 20.00 16.00 12.00 8.00 4.00 403 1E31N085A 4/24/98 06-IC-1 E31-R-1016-01 Rosemount 1152GP7-N22 psig 2.10 52.10 102.10 152.10 202.10 152.10 102.10 52.10 2.10 404 1E31N085A 4/24/98 06-IC-1 E31-R-1016-01 Rosemount 1152GP7-N22 mA 4.00 8.00 12.00 16.00 20.00 16.00 12.00 8.00 4.00 405 1E31N085B 5/4/10 06-IC-1 E31-R-1016-02 Rosemount 1152GP7-N22 psig 13.30 63.30 113.30 163.30 213.30 163.30 113.30 63.30 13.30 406 1E31N085B 5/4/10 06-IC-1 E31-R-1016-Q2 Rosemount 1152GP7-N22 mA 4.00 8.00 12.00 16.00 20.00 16.00 12.00 8.00 4.00

DRIFT ANALYSIS ENGINEERING DEPARTMENT GRAND GULF NUCLEAR STATION Rosemount Range Codes 5 - 8 Gage Pressure Transmitters Input Data JC-Q1111-09019 Rev. 0 Page 21 of 134 Instrument I Test Information Scaling Data Seq.

In lOut Pt 1 Pt2 Pt3 Pt4 Pt5 Pt6 Pt7 PtS Pt9 10 Tag 10 Date Procedure-Attachment MakelModel Units (0"10 Up)

(25"10 Up)

(50"10 Up)

(75"10 Up)

(100"10 Up)

(75"10 On)

(50"10 On)

(25"10 On)

(0"10 On) 407 1E31N085B 9/30/08 06-IC-1 E31-R-1016-02 Rosemount 1152GP7-N22 psig 13.30 63.30 113.30 163.30 213.30 163.30 113.30 63.30 13.30 408 1E31N085B 9/30/08 06-IC-1 E31-R-1016-02 Rosemount 1152GP7-N22 mA 4.00 8.00 12.00 16.00 20.00 16.00 12.00 8.00 4.00 409 1E31N085B 4/1/07 06-IC-1E31-R-1016-02 Rosemount 1152GP7-N22 psig 13.30 63.30 113.30 163.30 213.30 163.30 113.30 63.30 13.30 410 1E31N085B 4/1/07 06-IC-1 E31-R-1016-02 Rosemount 1152GP7-N22 mA 4.00 8.00 12.00 16.00 20.00 16.00 12.00 8.00 4.00 411 1E31N085B 9/27/05 06-IC-1 E31-R-1 016-02 Rosemount 1152GP7-N22 psig 13.30 63.30 113.30 163.30 213.30 163.30 113.30 63.30 13.30 412 1E31N085B 9/27/05 06-IC-1 E31-R-1016-02 Rosemount 1152GP7-N22 mA 4.00 8.00 12.00 16.00 20.00 16.00 12.00 8.00 4.00 413 1E31N085B 3/4/04 06-IC-1 E31-R-1016-02 Rosemount 1152GP7-N22 psig 13.30 63.30 113.30 163.30 213.30 163.30 113.30 63.30 13.30 414 1E31N085B 3/4/04 06-IC-1 E31-R-1016-02 Rosemount 1152GP7-N22 mA 4.00 8.00 12.00 16.00 20.00 16.00 12.00 8.00 4.00 415 1E31N085B 9/23/02 06-IC-1 E31-R-1016-Q2 Rosemount 1152GP7-N22 psig 13.30 63.30 113.30 163.30 213.30 163.30 113.30 63.30 13.30 416 1E31N085B 9/23/02 06-IC-1 E31-R-1016-02 Rosemount 1152GP7-N22 mA 4.00 8.00 12.00 16.00 20.00 16.00 12.00 8.00 4.00 417 1E31N085B 4/19/01 06-IC-1 E31-R-1016-02 Rosemount 1152GP7-N22 psig 13.30 63.30 113.30 163.30 213.30 163.30 113.30 63.30 13.30 418 1E31N085B 4/19/01 06-IC-1 E31-R-1016-02 Rosemount 1152GP7-N22 mA 4.00 8.00 12.00 16.00 20.00 16.00 12.00 8.00 4.00 419 1E31N085B 11/17/99 06-IC-1 E31-R-1016-Q2 Rosemount 1152GP7-N22 psig 13.30 63.30 113.30 163.30 213.30 163.30 113.30 63.30 13.30 420 1E31N085B 11/17/99 06-IC-1 E31-R-1016-Q2 Rosemount 1152GP7-N22 mA 4.00 8.00 12.00 16.00 20.00 16.00 12.00 8.00 4.00 421 1E31N085B 4/24/98 06-IC-1 E31-R-1016-02 Rosemount 1152GP7-N22 psig 13.30 63.30 113.30 163.30 213.30 163.30 113.30 63.30 13.30 422 1E31N085B 4/24/98 06-IC-1 E31-R-1016-02 Rosemount 1152GP7-N22 mA 4.00 8.00 12.00 16.00 20.00 16.00 12.00 8.00 4.00 423 1E32N050 5/4/10 06-IC-1 E32-R-1001-09 Rosemount 1153GD6PC psig 14.21 39.21 64.21 89.21 114.21 89.21 64.21 39.21 14.21 424 1E32N050 5/4/10 06-IC-1 E32-R-1 001-09 Rosemount 1153GD6PC mA 4.00 8.00 12.00 16.00 20.00 16.00 12.00 8.00 4.00 425 1E32N050 10/4/08 06-IC-1 E32-R-1001-09 Rosemount 1153GD6PC psig 14.21 39.21 64.21 89.21 114.21 89.21 64.21 39.21 14.21 426 1E32N050 10/4/08 06-IC-1 E32-R-1001-09 Rosemount 1153GD6PC mA 4.00 8.00 12.00 16.00 20.00 16.00 12.00 8.00 4.00 427 1E32N050 4/4/07 06-IC-1 E32-R-1 001-09 Rosemount 1153GD6PC psig 14.21 39.21 64.21 89.21 114.21 89.21 64.21 39.21 14.21

DRIFT ANALYSIS ENGINEERING DEPARTMENT GRAND GULF NUCLEAR STATION Rosemount Range Codes 5 - 8 Gage Pressure Transmitters Input Data JC-Q1111-09019 Rev. 0 Page 22 of 134 Instrument I Test Information Scaling Data Seq.

In lOut Pl1 Pt2 Pt3 Pl4 Pl5 Pt6 Pt 7 PtS Plg 10 Tag 10 Date Procedure-Attachment Make IModel Units (0% Up)

(25% Up)

(50% Up)

(75% Up)

(100% Up)

(75% On)

(50% On)

(25% On)

(0% On) 428 1E32N050 4/4/07 06-IC-1 E32-R-1001-09 Rosemount 1153GD6PC mA 4.00 8.00 12.00 16.00 20.00 16.00 12.00 8.00 4.00 429 1E32N050 9/29/05 06-IC-1 E32-R-1001-09 Rosemount 1153GD6PC psig 14.21 39.21 64.21 89.21 114.21 89.21 64.21 39.21 14.21 430 1E32N050 9/29/05 06-IC-1 E32-R-1 001-09 Rosemount 1153GD6PC mA 4.00 8.00 12.00 16.00 20.00 16.00 12.00 8.00 4.00 431 1E32N050 317104 06-IC-1 E32-R-1001-09 Rosemount 1153GD6PC psig 14.21 39.21 64.21 89.21 114.21 89.21 64.21 39.21 14.21 432 1E32N050 3/7/04 06-IC-1 E32-R-1001-09 Rosemount 1153GD6PC mA 4.00 8.00 12.00 16.00 20.00 16.00 12.00 8.00 4.00 433 1E32N050 9/28/02 06-IC-1 E32-R-1001-09 Rosemount 1153GD6PC psig 14.30 39.30 64.30 89.30 114.30 89.30 64.30 39.30 14.30 434 1E32N050 9/28/02 06-IC-1 E32-R-1 001-09 Rosemount 1153GD6PC rnA 4.00 8.00 12.00 16.00 20.00 16.00 12.00 8.00 4.00 435 1E32N050 5/3/01 06-IC-1 E32-R-1001-09 Rosemount 1153GD6PC psig 14.30 39.30 64.30 89.30 114.30 89.30 64.30 39.30 14.30 436 1E32N050 5/3/01 06-IC-1 E32-R-1 001-09 Rosemount 1153GD6PC mA 4.00 8.00 12.00 16.00 20.00 16.00 12.00 8.00 4.00 437 1E32N050 11/6/99 06-IC-1 E32-R-1001-09 Rosemount 1153GD6PC psig 14.30 39.30 64.30 89.30 114.30 89.30 64.30 39.30 14.30 438 1E32N050 11/6/99 06-IC-1 E32-R-1 001-09 Rosemount 1153GD6PC mA 4.00 8.00 12.00 16.00 20.00 16.00 12.00 8.00 4.00 439 1E32N050 5/31/99 06-IC-1 E32-R-1001-09 Rosemount 1153GD6PC psig 14.30 39.30 64.30 89.30 114.30 89.30 64.30 39.30 14.30 440 1E32N050 5/31/99 06-IC-1 E32-R-1001-09 Rosemount 1153GD6PC mA 4.00 8.00 12.00 16.00 20.00 16.00 12.00 8.00 4.00 441 1E32N050 10/6/97 06-IC-1 E32-R-1001-09 Rosemount 1153GD6PC psig 14.30 39.30 64.30 89.30 114.30 89.30 64.30 39.30 14.30 442 1E32N050 10/6/97 06-IC-1 E32-R-1001-09 Rosemount 1153GD6PC mA 4.00 8.00 12.00 16.00 20.00 16.00 12.00 8.00 4.00 443 1E32N055 7/8/09 06-IC-1 E32-R-1 001-1 0 Rosemount 1152GP6N22 psig 10.00 35.00 60.00 85.00 110.00 85.00 60.00 35.00 10.00 444 1E32N055 7/8/09 06-IC-1 E32-R-1001-10 Rosemount 1152GP6N22 mA 4.00 8.00 12.00 16.00 20.00 16.00 12.00 8.00 4.00 445 1E32N055 117108 06-IC-1 E32-R-1001-10 Rosemount 1152GP6N22 psig 10.00 35.00 60.00 85.00 110.00 85.00 60.00 35.00 10.00 446 1E32N055 1/7/08 06-IC-1 E32-R-1 001-1 0 Rosemount 1152GP6N22 mA 4.00 8.00 12.00 16.00 20.00 16.00 12.00 8.00 4.00 447 1E32N055 4/5/06 06-IC-1 E32-R-1 001-10 Rosemount 1152GP6N22 psig 10.00 35.00 60.00 85.00 110.00 85.00 60.00 35.00 10.00 448 1E32N055 4/5/06 06-IC-1 E32-R-1001-10 Rosemount 1152GP6N22 mA 4.00 8.00 12.00 16.00 20.00 16.00 12.00 8.00 4.00 449 1E32N055 10/6/04 06-IC-1 E32-R-1001-10 Rosemount 1152GP6N22 psig 10.00 35.00 60.00 85.00 110.00 85.00 60.00 35.00 10.00

DRIFT ANALYSIS ENGINEERING DEPARTMENT GRAND GULF NUCLEAR STATION Rosemount Range Codes 5 - 8 Gage Pressure Transmitters Input Data JC-Q1111-09019 Rev. 0 Page 23 of 134 Instrument I Test Information Scaling Data Seq.

In / Out Pt1 Pt2 Pt 3 Pt4 Pt5 Pt6 Pt7 pta Pt9 10 Tag 10 Date Procedure-Attachment Make/Model Units (0% Up)

(25% Up)

(50% Up)

(75% Up)

(100% Up)

(75% On)

(50% On)

(25% On)

(0% On) 450 1E32N055 10/6/04 06-IC-1E32-R-1001-10 Rosemount 1152GP6N22 mA 4.00 8.00 12.00 16.00 20.00 16.00 12.00 8.00 4.00 451 1E32N055 4/22/03 06-IC-1 E32-R-1 001-1 0 Rosemount 1152GP6N22 psig 10.00 35.00 60.00 85.00 110.00 85.00 60.00 35.00 10.00 452 1E32N055 4/22/03 06-IC-1 E32-R-1001-1 0 Rosemount 1152GP6N22 mA 4.00 8.00 12.00 16.00 20.00 16.00 12.00 8.00 4.00 453 1E32N055 11/19/01 06-IC-1 E32-R-1001-10 Rosemount 1152GP6N22 psig 10.00 35.00 60.00 85.00 110.00 85.00 60.00 35.00 10.00 454 1E32N055 11/19/01 06-IC-1 E32-R-1001-10 Rosemount 1152GP6N22 mA 4.00 8.00 12.00 16.00 20.00 16.00 12.00 8.00 4.00 455 1E32N055 8/17/00 06-IC-1 E32-R-1001-10 Rosemount 1152GP6N22 psig 10.00 35.00 60.00 85.00 110.00 85.00 60.00 35.00 10.00 456 1E32N055 8/17/00 06-IC-1 E32-R-1001-1 0 Rosemount 1152GP6N22 mA 4.00 8.00 12.00 16.00 20.00 16.00 12.00 8.00 4.00 457 1E32N055 2/16/99 06-IC-1 E32-R-1001-10 Rosemount 1152GP6N22 psig 10.00 35.00 60.00 85.00 110.00 85.00 60.00 35.00 10.00 458 1E32N055 2116/99 06-IC-1 E32-R-1001-10 Rosemount 1152GP6N22 mA 4.00 8.00 12.00 16.00 20.00 16.00 12.00 8.00 4.00 459 1E32N055 8/19/97 06-IC-1 E32-R-1 001-10 Rosemount 1152GP6N22 psig 10.00 35.00 60.00 85.00 110.00 85.00 60.00 35.00 10.00 460 1E32N055 8/19/97 06-IC-1 E32-R-1001-10 Rosemount 1152GP6N22 mA 4.00 8.00 12.00 16.00 20.00 16.00 12.00 8.00 4.00 461 1E32N058 4/30/10 06-IC-1 E32-R-1001-11 Rosemount 1153GD6PC psig 15.06 40.06 65.06 90.06 115.06 90.06 65.06 40.06 15.06 462 1E32N058 4/30/10 06-IC-1 E32-R-1001-11 Rosemount 1153GD6PC mA 4.00 8.00 12.00 16.00 20.00 16.00 12.00 8.00 4.00 463 1E32N058 10/2108 06-IC-1E32-R-1001-11 Rosemount 1153GD6PC psig 15.06 40.06 65.06 90.06 115.06 90.06 65.06 40.06 15.06 464 1E32N058 10/2/08 06-IC-1 E32-R-1 001-11 Rosemount 1153GD6PC rnA 4.00 8.00 12.00 16.00 20.00 16.00 12.00 8.00 4.00 465 1E32N058 3/25/07 06-IC-1 E32-R-1001-11 Rosemount 1153GD6PC psig 15.06 40.06 65.06 90.06 115.06 90.06 65.06 40.06 15.06 466 1E32N058 3/25/07 06-IC-1 E32-R-1001-11 Rosemount 1153GD6PC mA 4.00 8.00 12.00 16.00 20.00 16.00 12.00 8.00 4.00 467 1E32N058 9/22105 06-IC-1 E32-R-1001-11 Rosemount 1153GD6PC psig 15.06 40.06 65.06 90.06 115.06 90.06 65.06 40.06 15.06 468 1E32N058 9/22/05 06-IC-1 E32-R-1001-11 Rosemount 1153GD6PC mA 4.00 8.00 12.00 16.00 20.00 16.00 12.00 8.00 4.00 469 1E32N058 3/5/04 06-IC-1 E32-R-1001-11 Rosemount 1153GD6PC psig 15.06 40.06 65.06 90.06 115.06 90.06 65.06 40.06 15.06 470 1E32N058 3/5/04 06-IC-1 E32-R-1001-11 Rosemount 1153GD6PC mA 4.00 8.00 12.00 16.00 20.00 16.00 12.00 8.00 4.00 471 1E32N058 9/15/02 06-IC-1 E32-R-1001-11 Rosemount 1153GD6PC psig 14.40 39.40 64.40 89.40 114.40 89.40 64.40 39.40 14.40

DRIFT ANALYSIS ENGINEERING DEPARTMENT GRAND GULF NUCLEAR STATION Rosemount Range Codes 5 - 8 Gage Pressure Transmitters Input Data JC-Q1111-09019 Rev. 0 Page 24 of 134 Instrument I Test Information Scaling Data Seq.

In lOut Pt 1 Pt2 Pt3 Pt4 Pt5 Pt6 Pt 7 Pta Pt9 10 Tag 10 Date Procedure-Attachment Make/Model Units (0% Up)

(25% Up)

(50% Up)

(75% Up)

(100% Up)

(75% On)

(50% On)

(25% On)

(0% On) 472 1E32N058 9/15/02 06-IC-1 E32-R-1 001-11 Rosemount 1153GD6PC rnA 4.00 8.00 12.00 16.00 20.00 16.00 12.00 8.00 4.00 473 1E32N058 4/23/01 06-IC-1 E32-R-1001-11 Rosemount 1153GD6PC psig 14.40 39.40 64.40 89.40 114.40 89.40 64.40 39.40 14.40 474 1E32N058 4/23/01 06-IC-1 E32-R-1001-11 Rosemount 1153GD6PC rnA 4.00 8.00 12.00 16.00 20.00 16.00 12.00 8.00 4.00 475 1E32N058 11/9/99 06-IC-1 E32-R-1001-11 Rosemount 1153GD6PC psig 14.40 39.40 64.40 89.40 114.40 89.40 64.40 39.40 14.40 476 1E32N058 11/9/99 06-IC-1 E32-R-1001-11 Rosemount 1153GD6PC rnA 4.00 8.00 12.00 16.00 20.00 16.00 12.00 8.00 4.00 477 1E32N058 6/21/99 06-IC-1 E32-R-1001-11 Rosemount 1153GD6PC psig 14.40 39.40 64.40 89.40 114.40 89.40 64.40 39.40 14.40 478 1E32N058 6/21/99 06-IC-1 E32-R-1001-11 Rosemount 1153GD6PC rnA 4.00 8.00 12.00 16.00 20.00 16.00 12.00 8.00 4.00 479 1E32N058 10/28/97 06-IC-1E32-R-1001-11 Rosemount 1153GD6PC psig 14.40 39.40 64.40 89.40 114.40 89.40 64.40 39.40 14.40 480 1E32N058 10/28/97 06-IC-1 E32-R-1001-11 Rosemount 1153GD6PC rnA 4.00 8.00 12.00 16.00 20.00 16.00 12.00 8.00 4.00 481 1E32N061A 8/12/09 06-IC-1 E32-R-1001-05 Rosemount 1153GB6RC psig 11.17 36.17 61.17 86.17 111.17 86.17 61.17 36.17 11.17 482 1E32N061A 8/12109 06-IC-1 E32-R-1001-05 Rosemount 1153GB6RC rnA 4.00 8.00 12.00 16.00 20.00 16.00 12.00 8.00 4.00 483 1E32N061A 2115/08 06-IC-1 E32-R-1001-05 Rosemount 1153GB6RC psig 11.17 36.17 61.17 86.17 111.17 86.17 61.17 36.17 11.17 484 1E32N061A 2115/08 06-IC-1 E32-R-1001-Q5 Rosemount 1153GB6RC rnA 4.00 8.00 12.00 16.00 20.00 16.00 12.00 8.00 4.00 485 1E32N061A 8/28/06 06-IC-1 E32-R-1001-05 Rosemount 1153GB6RC psig 11.17 36.17 61.17 86.17 111.17 86.17 61.17 36.17 11.17 486 1E32N061A 8/28/06 06-IC-1 E32-R-1 001-05 Rosemount 1153GB6RC rnA 4.00 8.00 12.00 16.00 20.00 16.00 12.00 8.00 4.00 487 1E32N061A 1/7/05 06-IC-1 E32-R-1001-05 Rosemount 1153GB6RC psig 11.17 36.17 61.17 86.17 111.17 86.17 61.17 36.17 11.17 488 1E32N061A 1/7/05 06-IC-1 E32-R-1001-05 Rosemount 1153GB6RC rnA 4.00 8.00 12.00 16.00 20.00 16.00 12.00 8.00 4.00 489 1E32N061A 5/13/03 06-IC-1 E32-R-1 001-05 Rosemount 1153GB6RC psig 10.40 35.40 60.40 85.40 110.40 85.40 60.40 35.40 10.40 490 1E32N061A 5/13/03 06-IC-1 E32-R-1001-05 Rosemount 1153GB6RC rnA 4.00 8.00 12.00 16.00 20.00 16.00 12.00 8.00 4.00 491 1E32N061A 11/26/01 06-IC-1 E32-R-1001-05 Rosemount 1153GB6RC psig 10.40 35.40 60.40 85.40 110.40 85.40 60.40 35.40 10.40 492 1E32N061A 11/26/01 06-IC-1 E32-R-1001-05 Rosemount 1153GB6RC rnA 4.00 8.00 12.00 16.00 20.00 16.00 12.00 8.00 4.00 493 1E32N061A 10/2/00 06-IC-1 E32-R-1001-05 Rosemount 1153GB6RC psig 10.40 35.40 60.40 85.40 110.40 85.40 60.40 35.40 10.40

DRIFT ANALYSIS ENGINEERING DEPARTMENT GRAND GULF NUCLEAR STATION Rosemount Range Codes 5 - 8 Gage Pressure Transmitters Input Data JC-Q1111-09019 Rev. 0 Page 25 of 134 Instrument I Test Information Scaling Data Seq.

In / Out Pt 1 Pt2 Pt3 Pt4 Pt 5 Pt6 Pt7 PtS Pt9 10 Tag 10 Date Procedure-Attachment Make/Model Units (0% Up)

(25% Up)

(50% Up)

(75% Up)

(100% Up)

(75% On)

(50% On)

(25% On)

(0% On) 494 1E32N061A 10/2/00 06-IC-1E32-R-1001-05 Rosemount 1153GB6RC mA 4.00 8.00 12.00 16.00 20.00 16.00 12.00 8.00 4.00 495 1E32N061A 4/9/99 06-IC-1 E32-R-1001-05 Rosemount 1153GB6RC psig 10.40 35.40 60.40 85.40 110.40 85.40 60.40 35.40 10.40 496 1E32N061A 4/9/99 06-IC-1 E32-R-1 001-05 Rosemount 1153GB6RC mA 4.00 8.00 12.00 16.00 20.00 16.00 12.00 8.00 4.00 497 1E32N061A 10/8/97 06-IC-1 E32-R-1001-05 Rosemount 1153GB6RC psig 10.40 35.40 60.40 85.40 110.40 85.40 60.40 35.40 10.40 498 1E32N061A 10/8/97 06-IC-1E32-R-1001-05 Rosemount 1153GB6RC mA 4.00 8.00 12.00 16.00 20.00 16.00 12.00 8.00 4.00 499 1E32N061E 11/2/09 06-IC-1 E32-R-1001-06 Rosemount 1153GB6RC psig 11.17 36.17 61.17 86.17 111.17 86.17 61.17 36.17 11.17 500 1E32N061E 11/2/09 06-IC-1 E32-R-1001-Q6 Rosemount 1153GB6RC mA 4.00 8.00 12.00 16.00 20.00 16.00 12.00 8.00 4.00 501 1E32N061E 1/30/08 06-IC-1 E32-R-1001-Q6 Rosemount 1153GB6RC psig 11.17 36.17 61.17 86.17 111.17 86.17 61.17 36.17 11.17 502 1E32N061E 1/30/08 06-IC-1 E32-R-1001-06 Rosemount 1153GB6RC mA 4.00 8.00 12.00 16.00 20.00 16.00 12.00 8.00 4.00 503 1E32N061E 4/14/06 06-IC-1 E32-R-1 001-06 Rosemount 1153GB6RC psig 11.17 36.17 61.17 86.17 111.17 86.17 61.17 36.17 11.17 504 1E32N061E 4/14/06 06-IC-1 E32-R-1001-06 Rosemount 1153GB6RC mA 4.00 8.00 12.00 16.00 20.00 16.00 12.00 8.00 4.00 505 1E32N061E 10/28/04 06-IC-1 E32-R-1001-06 Rosemount 1153GB6RC psig 11.17 36.17 61.17 86.17 111.17 86.17 61.17 36.17 11.17 506 1E32N061E 10/28/04 06-IC-1 E32-R-1001-06 Rosemount 1153GB6RC mA 4.00 8.00 12.00 16.00 20.00 16.00 12.00 8.00 4.00 507 1E32N061E 5/28/03 06-1C-1 E32-R-1 001-06 Rosemount 1153GB6RC psig 10.40 35.40 60.40 85.40 110.40 85.40 60.40 35.40 10.40 508 1E32N061E 5/28/03 06-IC-1 E32-R-1001-06 Rosemount 1153GB6RC mA 4.00 8.00 12.00 16.00 20.00 16.00 12.00 8.00 4.00 509 1E32N061E 11/28/01 06-IC-1 E32-R-1 001-06 Rosemount 1153GB6RC psig 10.40 35.40 60.40 85.40 110.40 85.40 60.40 35.40 10.40 510 1E32N061E 11/28/01 06-IC-1 E32-R-1 001-06 Rosemount 1153GB6RC mA 4.00 8.00 12.00 16.00 20.00 16.00 12.00 8.00 4.00 511 1E32N061E 11/30/00 06-IC-1 E32-R-1001-Q6 Rosemount 1153GB6RC psig 10.40 35.40 60.40 85.40 110.40 85.40 60.40 35.40 10.40 512 1E32N061E 11/30/00 06-IC-1 E32-R-1 001-06 Rosemount 1153GB6RC mA 4.00 8.00 12.00 16.00 20.00 16.00 12.00 8.00 4.00 513 1E32N061E 4/9/99 06-IC-1 E32-R-1001-Q6 Rosemount 1153GB6RC psig 10.40 35.40 60.40 85.40 110.40 85.40 60.40 35.40 10.40 514 1E32N061E 4/9/99 06-IC-1 E32-R-1001-06 Rosemount 1153GB6RC mA 4.00 8.00 12.00 16.00 20.00 16.00 12.00 8.00 4.00 515 1E32N061E 10/8/97 06-IC-1 E32-R-1001-06 Rosemount 1153GB6RC psig 10.40 35.40 60.40 85.40 110.40 85.40 60.40 35.40 10.40

DRIFT ANALYSIS ENGINEERING DEPARTMENT GRAND GULF NUCLEAR STATION Rosemount Range Codes 5 - 8 Gage Pressure Transmitters Input Data JC-Q1111-09019 Rev. 0 Page 26 of 134 Instrument I Test Information Scaling Data Seq.

In lOut Pt 1 Pt2 Pt3 pt4 pt5 Pt6 pt7 PtS Ptg 10 Tag 10 Oate Procedure-Attachment Make IModel Units (0% Up)

(25% Up)

(50% Up)

(75% Up)

(100% Up)

(75% On)

(50% On)

(25% On)

(0% On) 516 1E32N061E 10/8/97 06-IC-1 E32-R-1001-Q6 Rosemount 1153GB6RC rnA 4.00 8.00 12.00 16.00 20.00 16.00 12.00 8.00 4.00 517 1E32N061J 5/5/09 06-IC-1 E32-R-1001-07 Rosemount 1152GP6N22 psig 11.14 36.14 61.14 86.14 111.14 86.14 61.14 36.14 11.14 518 1E32N061J 5/5/09 06-IC-1 E32-R-1001-07 Rosemount 1152GP6N22 rnA 4.00 8.00 12.00 16.00 20.00 16.00 12.00 8.00 4.00 519 1E32N061J 11/9/07 06-IC-1 E32-R-1001-Q7 Rosemount 1152GP6N22 psig 11.14 36.14 61.14 86.14 111.14 86.14 61.14 36.14 11.14 520 1E32N061J 11/9/07 06-IC-1 E32-R-1001-07 Rosemount 1152GP6N22 rnA 4.00 8.00 12.00 16.00 20.00 16.00 12.00 8.00 4.00 521 1E32N061J 5/11/06 06-IC-1 E32-R-1001-Q7 Rosemount 1152GP6N22 psig 11.14 36.14 61.14 86.14 111.14 86.14 61.14 36.14 11.14 522 1E32N061J 5/11/06 06-IC-1 E32-R-1001-Q7 Rosemount 1152GP6N22 rnA 4.00 8.00 12.00 16.00 20.00 16.00 12.00 8.00 4.00 523 1E32N061J 9/29/04 06-IC-1 E32-R-1001-07 Rosemount 1152GP6N22 psig 11.14 36.14 61.14 86.14 111.14 86.14 61.14 36.14 11.14 524 1E32N061J 9/29/04 06-IC-1 E32-R-1001-07 Rosemount 1152GP6N22 rnA 4.00 8.00 12.00 16.00 20.00 16.00 12.00 8.00 4.00 525 1E32N061J 4/3/03 06-IC-1 E32-R-1001-07 Rosemount 1152GP6N22 psig 10.40 35.40 60.40 85.40 110.40 85.40 60.40 35.40 10.40 526 1E32N061J 4/3/03 06-IC-1 E32-R-1001-07 Rosemount 1152GP6N22 rnA 4.00 8.00 12.00 16.00 20.00 16.00 12.00 8.00 4.00 527 1E32N061J 11/12101 06-IC-1 E32-R-1001-07 Rosemount 1152GP6N22 psig 10.40 35.40 60.40 85.40 110.40 85.40 60.40 35.40 10.40 528 1E32N061J 11/12101 06-IC-1 E32-R-1001-07 Rosemount 1152GP6N22 rnA 4.00 8.00 12.00 16.00 20.00 16.00 12.00 8.00 4.00 529 1E32N061J 7/24/00 06-IC-1 E32-R-1001-07 Rosemount 1152GP6N22 psig 10.40 35.40 60.40 85.40 110.40 85.40 60.40 35.40 10.40 530 1E32N061J 7/24/00 06-IC-1E32-R-1001-Q7 Rosemount 1152GP6N22 rnA 4.00 8.00 12.00 16.00 20.00 16.00 12.00 8.00 4.00 531 1E32N061J 1/27/99 06-IC-1 E32-R-1 001-07 Rosemount 1152GP6N22 psig 10.40 35.40 60.40 85.40 110.40 85.40 60.40 35.40 10.40 532 1E32N061J 1/27/99 06-IC-1 E32-R-1001-07 Rosemount 1152GP6N22 rnA 4.00 8.00 12.00 16.00 20.00 16.00 12.00 8.00 4.00 533 1E32N061J 7/16/97 06-IC-1E32-R-1001-Q7 Rosemount 1152GP6N22 psig 10.40 35.40 60.40 85.40 110.40 85.40 60.40 35.40 10.40 534 1E32N061J 7/16/97 06-IC-1 E32-R-1001-07 Rosemount 1152GP6N22 rnA 4.00 8.00 12.00 16.00 20.00 16.00 12.00 8.00 4.00 535 1E32N061N 1218/09 06-IC-1E32-R-1001-08 Rosemount 1153GB6RC psig 11.16 36.16 61.16 86.16 111.16 86.16 61.16 36.16 11.16 536 1E32N061N 1218/09 06-IC-1E32-R-1001-Q8 Rosemount 1153GB6RC rnA 4.00 8.00 12.00 16.00 20.00 16.00 12.00 8.00 4.00 537 1E32N061N 6/16/08 06-IC-1 E32-R-1001-08 Rosemount 1153GB6RC psig 11.16 36.16 61.16 86.16 111.16 86.16 61.16 36.16 11.16

DRIFT ANALYSIS ENGINEERING DEPARTMENT GRAND GULF NUCLEAR STATION Rosemount Range Codes 5 - 8 Gage Pressure Transmitters Input Data JC-Q1111-09019 Rev. 0 Page 27 of 134 Instrument I Test Information Scaling Data Seq.

In / Out Pt 1 Pt2 Pt3 Pt4 Pt 5 Pt6 Pt7 Pt8 Ptg 10 Tag 10 Date Procedure-Attachment Make/Model Units (0% Up)

(25% Up)

(50% Up)

(75% Up)

(100% Up)

(75% On)

(50% On)

(25% On)

(0% On) 538 1E32N061N 6/16/08 06-IC-1 E32-R-1001-Q8 Rosemount 1153GB6RC rnA 4.00 8.00 12.00 16.00 20.00 16.00 12.00 8.00 4.00 539 1E32N061N 8/28/06 06-IC-1 E32-R-1001-08 Rosemount 1153GB6RC psig 11.16 36.16 61.16 86.16 111.16 86.16 61.16 36.16 11.16 540 1E32N061N 8/28/06 06-IC-1 E32-R-1 001-08 Rosemount 1153GB6RC mA 4.00 8.00 12.00 16.00 20.00 16.00 12.00 8.00 4.00 541 1E32N061N 1/7/05 06-IC-1 E32-R-1001-08 Rosemount 1153GB6RC psig 11.16 36.16 61.16 86.16 111.16 86.16 61.16 36.16 11.16 542 1E32N061N 1/7/05 06-IC-1 E32-R-1001-08 Rosemount 1153GB6RC mA 4.00 8.00 12.00 16.00 20.00 16.00 12.00 8.00 4.00 543 1E32N061N 5/16/03 06-IC-1 E32-R-1001-Q8 Rosemount 1153GB6RC psig 10.40 35.40 60.40 85.40 110.40 85.40 60.40 35.40 10.40 544 1E32N061N 5/16/03 06-IC-1 E32-R-1001-08 Rosemount 1153GB6RC mA 4.00 8.00 12.00 16.00 20.00 16.00 12.00 8.00 4.00 545 1E32N061N 11/12/01 06-IC-1 E32-R-1001-08 Rosemount 1153GB6RC psig 10.40 35.40 60.40 85.40 110.40 85.40 60.40 35.40 10.40 546 1E32N061N 11/12101 06-IC-1 E32-R-1001-08 Rosemount 1153GB6RC rnA 4.00 8.00 12.00 16.00 20.00 16.00 12.00 8.00 4.00 547 1E32N061N 10/2/00 06-IC-1 E32-R-1001-08 Rosemount 1153GB6RC psig 10.40 35.40 60.40 85.40 110.40 85.40 60.40 35.40 10.40 548 1E32N061N 10/2100 06-IC-1 E32-R-1001-08 Rosemount 1153GB6RC rnA 4.00 8.00 12.00 16.00 20.00 16.00 12.00 8.00 4.00 549 1E32N061N 4/10/99 06-IC-1 E32-R-1001-08 Rosemount 1153GB6RC psig 10.40 35.40 60.40 85.40 110.40 85.40 60.40 35.40 10.40 550 1E32N061N 4/10/99 06-IC-1 E32-R-1001-08 Rosemount 1153GB6RC rnA 4.00 8.00 12.00 16.00 20.00 16.00 12.00 8.00 4.00 551 1E32N061N 10/7/97 06-IC-1 E32-R-1001-08 Rosemount 1153GB6RC psig 10.40 35.40 60.40 85.40 110.40 85.40 60.40 35.40 10.40 552 1E32N061N 10/7/97 06-IC-1 E32-R-1001-08 Rosemount 1153GB6RC mA 4.00 8.00 12.00 16.00 20.00 16.00 12.00 8.00 4.00 553 1E51N035A 4/24/10 06-IC-1 E51-R-0002-01 Rosemount 1153GB5 InWC 15.00 135.00 250.00 370.00 490.00 370.00 250.00 135.00 15.00 554 1E51 N035A 4/24/10 06-IC-1 E51-R-0002-01 Rosemount 1153GB5 mA 4.03 8.05 11.90 15.92 19.94 15.92 11.90 8.05 4.03 555 1E51N035A 7/2/08 06-IC-1 E51-R-0002-Q1 Rosemount 1153GB5 inWC 15.00 135.00 250.00 370.00 490.00 370.00 250.00 135.00 15.00 556 1E51N035A 7/2/08 06-IC-1 E51-R-0002-Q1 Rosemount 1153GB5 mA 4.03 8.05 11.90 15.92 19.94 15.92 11.90 8.05 4.03 557 1E51 N035A 2/1/08 06-IC-1 E51-R-0002-01 Rosemount 1153GB5 inWC 15.00 135.00 250.00 370.00 490.00 370.00 250.00 135.00 15.00 558 1E51N035A 2/1/08 06-IC-1 E51-R-0002-01 Rosemount 1153GB5 mA 4.03 8.05 11.90 15.92 19.94 15.92 11.90 8.05 4.03 559 1E51N035A 8/5/06 06-IC-1 E51-R-0002-01 Rosemount 1153GB5 inWC 15.00 135.00 250.00 370.00 490.00 370.00 250.00 135.00 15.00

DRIFT ANALYSIS ENGINEERING DEPARTMENT GRAND GULF NUCLEAR STATION Rosemount Range Codes 5 - 8 Gage Pressure Transmitters Input Data JC-Q1111-09019 Rev. 0 Page 28 of 134 Instrument I Test Information Scaling Data Seq.

In lOut Pt 1 Pt2 Pt 3 Pt4 Pt5 Pt6 Pt7 PtS Ptg 10 Tag 10 Date Procedure-Attachment Make IModel Units (0% Up)

(25% Up)

(50% Up)

(75% Up)

(100% Up)

(75% On)

(50% On)

(25% On)

(0% On) 560 1E51N035A 8/5/06 06-1C-1 E51-R-0002-Q1 Rosemount 1153GB5 mA 4.03 8.05 11.90 15.92 19.94 15.92 11.90 8.05 4.03 561 1E51N035E 4/25/10 06-IC-1 E51-R-0002-02 Rosemount 1153GB5 InWC 15.00 135.00 250.00 370.00 490.00 370.00 250.00 135.00 15.00 562 1E51N035E 4/25/10 06-IC-1 E51-R-0002-02 Rosemount 1153GB5 mA 4.02 8.04 11.90 15.92 19.94 15.92 11.90 8.04 4.02 563 1E51N035E 6/30/08 06-IC-1 E51-R-0002-02 Rosemount 1153GB5 inWC 15.00 135.00 250.00 370.00 490.00 370.00 250.00 135.00 15.00 564 1E51N035E 6/30/08 06-IC-1 E51-R-0002-02 Rosemount 1153GB5 mA 4.02 8.04 11.90 15.92 19.94 15.92 11.90 8.04 4.02 565 1E51N035E 10/8/06 06-IC-1 E51-R-0002-02 Rosemount 1153GB5 inWC 15.00 135.00 250.00 370.00 490.00 370.00 250.00 135.00 15.00 566 1E51N035E 10/8/06 06-IC-1E51-R-0002-02 Rosemount 1153GB5 mA 4.02 8.04 11.90 15.92 19.94 15.92 11.90 8.04 4.02 567 1E51N055A 6/29/09 06-IC-1 E51-R-0001-01 Rosemount 1152GP6-N22 psig 0.00 7.50 15.00 22.50 30.00 22.50 15.00 7.50 0.00 568 1E51N055A 6/29/09 06-IC-1 E51-R-0001-01 Rosemount 1152GP6-N22 mA 4.00 8.00 12.00 16.00 20.00 16.00 12.00 8.00 4.00 569 1E51N055A 1/2/08 06-IC-1 E51-R-0001-01 Rosemount 1152GP6-N22 psig 0.00 7.50 15.00 22.50 30.00 22.50 15.00 7.50 0.00 570 1E51N055A 1/2108 06-IC-1 E51-R-0001-01 Rosemount 1152GP6-N22 mA 4.00 8.00 12.00 16.00 20.00 16.00 12.00 8.00 4.00 571 1E51N055A 3/18/06 06-IC-1 E51-R-0001-01 Rosemount 1152GP6-N22 psig 0.00 7.50 15.00 22.50 30.00 22.50 15.00 7.50 0.00 572 1E51N055A 3/18/06 06-IC-1 E51-R-0001-01 Rosemount 1152GP6-N22 mA 4.00 8.00 12.00 16.00 20.00 16.00 12.00 8.00 4.00 573 1E51N055A 8/4/04 06-IC-1 E51-R-0001-01 Rosemount 1152GP6-N22 psig 0.00 7.50 15.00 22.50 30.00 22.50 15.00 7.50 0.00 574 1E51N055A 8/4/04 06-IC-1 E51-R-0001-01 Rosemount 1152GP6-N22 mA 4.00 8.00 12.00 16.00 20.00 16.00 12.00 8.00 4.00 575 1E51N055A 2119/03 06-IC-1 E51-R-0001-01 Rosemount 1152GP6-N22 psig 0.00 7.50 15.00 22.50 30.00 22.50 15.00 7.50 0.00 576 1E51N055A 2/19/03 06-IC-1 E51-R-0001-01 Rosemount 1152GP6-N22 mA 4.00 8.00 12.00 16.00 20.00 16.00 12.00 8.00 4.00 577 1E51N055A 4/24/01 06-IC-1 E51-R-0001-01 Rosemount 1152GP6-N22 psig 0.00 7.50 15.00 22.50 30.00 22.50 15.00 7.50 0.00 578 1E51N055A 4/24/01 06-IC-1 E51-R-0001-01 Rosemount 1152GP6-N22 mA 4.00 8.00 12.00 16.00 20.00 16.00 12.00 8.00 4.00 579 1E51N055A 10/29/99 06-IC-1 E51-R-0001-01 Rosemount 1152GP6-N22 psig 0.00 7.50 15.00 22.50 30.00 22.50 15.00 7.50 0.00 580 1E51N055A 10/29/99 06-IC-1 E51-R-0001-01 Rosemount 1152GP6-N22 mA 4.00 8.00 12.00 16.00 20.00 16.00 12.00 8.00 4.00

DRIFT ANALYSIS ENGINEERING DEPARTMENT GRAND GULF NUCLEAR STATION Rosemount Range Codes 5 - 8 Gage Pressure Transmitters Input Data JC-Q1111-09019 Rev. 0 Page 29 of 134 Instrument I Test Information Scaling Data Seq.

In / Out Pt1 Pt2 Pt3 Pt4 Pt 5 Pt6 Pt 7 PtS Pt9 10 Tag 10 Date Procedure-Attachment Make/Model Units (0% Up)

(25% Up)

(50% Up)

(75% Up)

(100% Up)

(75% On)

(50% On)

(25% On)

(0% On) 581 1E51N055A 4/20/98 06-IC-1 E51-R-0001-01 Rosemount 1152GP6-N22 psig 0.00 7.50 15.00 22.50 30.00 22.50 15.00 7.50 0.00 582 1E51N055A 4/20/98 06-IC-1 E51-R-0001-01 Rosemount 1152GP6-N22 rnA 4.00 8.00 12.00 16.00 20.00 16.00 12.00 8.00 4.00 583 1E51N0558 11/4/10 06-IC-1 E51-R-0001-02 Rosemount 1152GP6-N22 psig 0.00 7.50 15.00 22.50 30.00 22.50 15.00 7.50 0.00 584 1E51N0558 11/4/10 06-IC-1 E51-R-0001-02 Rosemount 1152GP6-N22 rnA 4.00 8.00 12.00 16.00 20.00 16.00 12.00 8.00 4.00 585 1E51N0558 1/22/09 06-IC-1E51-R-0001-02 Rosemount 1152GP6-N22 psig 0.00 7.50 15.00 22.50 30.00 22.50 15.00 7.50 0.00 586 1E51N0558 1/22/09 06-IC-1 E51-R-0001-02 Rosemount 1152GP6-N22 rnA 4.00 8.00 12.00 16.00 20.00 16.00 12.00 8.00 4.00 587 1E51N0558 8/10/07 06-IC-1 E51-R-0001-02 Rosemount 1152GP6-N22 psig 0.00 7.50 15.00 22.50 30.00 22.50 15.00 7.50 0.00 588 1E51N0558 8/10/07 06-IC-1 E51-R-0001-02 Rosemount 1152GP6-N22 rnA 4.00 8.00 12.00 16.00 20.00 16.00 12.00 8.00 4.00 589 1E51N0558 219/06 06-IC-1 E51-R-0001-02 Rosemount 1152GP6-N22 psig 0.00 7.50 15.00 22.50 30.00 22.50 15.00 7.50 0.00 590 1E51N0558 2/9/06 06-IC-1 E51-R-0001-02 Rosemount 1152GP6-N22 rnA 4.00 8.00 12.00 16.00 20.00 16.00 12.00 8.00 4.00 591 1E51N0558 5/4/04 06-IC-1 E51-R-0001-02 Rosemount 1152GP6-N22 psig 0.00 7.50 15.00 22.50 30.00 22.50 15.00 7.50 0.00 592 1E51N0558 5/4/04 06-IC-1 E51-R-0001-02 Rosemount 1152GP6-N22 rnA 4.00 8.00 12.00 16.00 20.00 16.00 12.00 8.00 4.00 593 1E51N0558 11/20102 06-IC-1 E51-R-0001-02 Rosemount 1152GP6-N22 psig 0.00 7.50 15.00 22.50 30.00 22.50 15.00 7.50 0.00 594 1E51N0558 11/20102 06-IC-1 E51-R-0001-o2 Rosemount 1152GP6-N22 rnA 4.00 8.00 12.00 16.00 20.00 16.00 12.00 8.00 4.00 595 1E51N0558 4/20/01 06-IC-1 E51-R-0001-02 Rosemount 1152GP6-N22 psig 0.00 7.50 15.00 22.50 30.00 22.50 15.00 7.50 0.00 596 1E51N0558 4/20101 06-IC-1 E51-R-0001-02 Rosemount 1152GP6-N22 rnA 4.00 8.00 12.00 16.00 20.00 16.00 12.00 8.00 4.00 597 1E51N0558 11/16/99 06-IC-1 E51-R-0001-02 Rosemount 1152GP6-N22 psig 0.00 7.50 15.00 22.50 30.00 22.50 15.00 7.50 0.00 598 1E51N0558 11/16/99 06-IC-1 E51-R-0001-02 Rosemount 1152GP6-N22 rnA 4.00 8.00 12.00 16.00 20.00 16.00 12.00 8.00 4.00 599 1E51N0558 4/20/98 06-1C-1 E51-R-0001-02 Rosemount 1152GP6-N22 psig 0.00 7.50 15.00 22.50 30.00 22.50 15.00 7.50 0.00 600 1E51N0558 4/20/98 06-IC-1 E51-R-0001-02 Rosemount 1152GP6-N22 rnA 4.00 8.00 12.00 16.00 20.00 16.00 12.00 8.00 4.00 601 1E51N055E 2/26/10 06-IC-1 E51-R-0001-03 Rosemount 1152GP6-N22 psig 0.00 7.50 15.00 22.50 30.00 22.50 15.00 7.50 0.00 602 1E51N055E 2/26/10 06-IC-1 E51-R-0001-03 Rosemount 1152GP6-N22 rnA 4.00 8.00 12.00 16.00 20.00 16.00 12.00 8.00 4.00

DRIFT ANALYSIS ENGINEERING DEPARTMENT GRAND GULF NUCLEAR STATION Rosemount Range Codes 5 - 8 Gage Pressure Transmitters Input Data JC-Q1111-09019 Rev. 0 Page 30 of 134 Instrument I Test Information Scaling Data Seq.

In lOut Pt 1 Pt2 Pt3 Pt4 Pt5 Pt 6 Pt 7 pta Pt9 10 Tag 10 Date Procedure-Attachment Make IModel Units (0% Up)

(25% Up)

(50% Up)

(75% Up)

(100% Up)

(75% On)

(50% On)

(25% On)

(0% On) 603 1E51N055E 7/3/08 06-1C-1 E51-R-0001-03 Rosemount 1152GP6-N22 psig 0.00 7.50 15.00 22.50 30.00 22.50 15.00 7.50 0.00 604 1E51N055E 7/3/08 06-IC-1 E51-R-0001-03 Rosemount 1152GP6-N22 mA 4.00 8.00 12.00 16.00 20.00 16.00 12.00 8.00 4.00 605 1E51N055E 10/10/06 06-IC-1 E51-R-0001-03 Rosemount 1152GP6-N22 psig 0.00 7.50 15.00 22.50 30.00 22.50 15.00 7.50 0.00 606 1E51N055E 10/10/06 06-IC-1 E51-R-0001-03 Rosemount 1152GP6-N22 mA 4.00 8.00 12.00 16.00 20.00 16.00 12.00 8.00 4.00 607 1E51N055E 12121/04 06-IC-1 E51-R-0001-Q3 Rosemount 1152GP6-N22 psig 0.00 7.50 15.00 22.50 30.00 22.50 15.00 7.50 0.00 608 1E51N055E 12/21/04 06-IC-1 E51-R-0001-03 Rosemount 1152GP6-N22 mA 4.00 8.00 12.00 16.00 20.00 16.00 12.00 8.00 4.00 609 1E51N055E 2/19/03 06-IC-1E51-R-0001-03 Rosemount 1152GP6-N22 psig 0.00 7.50 15.00 22.50 30.00 22.50 15.00 7.50 0.00 610 1E51N055E 2/19/03 06-IC-1 E51-R-0001-03 Rosemount 1152GP6-N22 mA 4.00 8.00 12.00 16.00 20.00 16.00 12.00 8.00 4.00 611 1E51N055E 4/25/01 06-IC-1E51-R-0001-03 Rosemount 1152GP6-N22 psig 0.00 7.50 15.00 22.50 30.00 22.50 15.00 7.50 0.00 612 1E51N055E 4/25/01 06-IC-1E51-R-0001-03 Rosemount 1152GP6-N22 mA 4.00 8.00 12.00 16.00 20.00 16.00 12.00 8.00 4.00 613 1E51N055E 10/29/99 06-IC-1 E51-R-0001-03 Rosemount 1152GP6-N22 psig 0.00 7.50 15.00 22.50 30.00 22.50 15.00 7.50 0.00 614 1E51N055E 10/29/99 06-IC-1E51-R-0001-Q3 Rosemount 1152GP6-N22 mA 4.00 8.00 12.00 16.00 20.00 16.00 12.00 8.00 4.00 615 1E51N055E 4/20/98 06-IC-1 E51-R-0001-03 Rosemount 1152GP6-N22 psig 0.00 7.50 15.00 22.50 30.00 22.50 15.00 7.50 0.00 616 1E51N055E 4/20/98 06-IC-1 E51-R-0001-03 Rosemount 1152GP6-N22 mA 4.00 8.00 12.00 16.00 20.00 16.00 12.00 8.00 4.00 617 1E51N055F 6/9/09 06-IC-1E51-R-0001-04 Rosemount 1152GP6-N22 psig 0.00 7.50 15.00 22.50 30.00 22.50 15.00 7.50 0.00 618 1E51N055F 6/9/09 06-IC-1 E51-R-0001-04 Rosemount 1152GP6-N22 mA 4.00 8.00 12.00 16.00 20.00 16.00 12.00 8.00 4.00 619 1E51N055F 9/20/07 06-IC-1E51-R-0001-04 Rosemount 1152GP6-N22 psig 0.00 7.50 15.00 22.50 30.00 22.50 15.00 7.50 0.00 620 1E51N055F 9/20/07 06-IC-1 E51-R-0001-04 Rosemount 1152GP6-N22 rnA 4.00 8.00 12.00 16.00 20.00 16.00 12.00 8.00 4.00 621 1E51N055F 1/24/06 06-IC-1 E51-R-0001-04 Rosemount 1152GP6-N22 psig 0.00 7.50 15.00 22.50 30.00 22.50 15.00 7.50 0.00 622 1E51N055F 1/24/06 06-IC-1 E51-R-0001-04 Rosemount 1152GP6-N22 mA 4.00 8.00 12.00 16.00 20.00 16.00 12.00 8.00 4.00 623 1E51N055F 5/6/04 06-IC-1 E51-R-0001-04 Rosemount 1152GP6-N22 psig 0.00 7.50 15.00 22.50 30.00 22.50 15.00 7.50 0.00 624 1E51N055F 5/6/04 06-1C-1 E51-R-0001-04 Rosemount 1152GP6-N22 mA 4.00 8.00 12.00 16.00 20.00 16.00 12.00 8.00 4.00

DRIFT ANALYSIS ENGINEERING DEPARTMENT GRAND GULF NUCLEAR STATION Rosemount Range Codes 5 - 8 Gage Pressure Transmitters Input Data JC-Q1111-09019 Rev. 0 Page 31 of 134 Instrument I Test Information Scaling Data Seq.

In lOut pt1 pt2 Pt3 pt4 Pt 5 Pt6 Pt 7 Pta ptg 10 Tag 10 Date Procedure-Attachment Make IModel Units (0% Up)

(25% Up)

(50% Up)

(75% Up)

(100% Up)

(75% On)

(50% On)

(25% On)

(0% On) 625 1E51N055F 11/21/02 06-IC-1 E51-R-0001-04 Rosemount 1152GP6-N22 psig 0.00 7.50 15.00 22.50 30.00 22.50 15.00 7.50 0.00 626 1E51N055F 11/21/02 06-IC-1 E51-R-0001-04 Rosemount 1152GP6-N22 mA 4.00 8.00 12.00 16.00 20.00 16.00 12.00 8.00 4.00 627 1E51N055F 4/20/01 06-IC-1 E51-R-0001-04 Rosemount 1152GP6-N22 psig 0.00 7.50 15.00 22.50 30.00 22.50 15.00 7.50 0.00 628 1E51N055F 4/20/01 06-IC-1 E51-R-0001-04 Rosemount 1152GP6-N22 rnA 4.00 8.00 12.00 16.00 20.00 16.00 12.00 8.00 4.00 629 1E51N055F 11/16/99 06-IC-1 E51-R-0001-04 Rosemount 1152GP6-N22 psig 0.00 7.50 15.00 22.50 30.00 22.50 15.00 7.50 0.00 630 1E51N055F 11/16/99 06-IC-1 E51-R-0001-Q4 Rosemount 1152GP6-N22 mA 4.00 8.00 12.00 16.00 20.00 16.00 12.00 8.00 4.00 631 1E51N055F 4/20/98 06-IC-1 E51-R-0001-04 Rosemount 1152GP6-N22 psig 0.00 7.50 15.00 22.50 30.00 22.50 15.00 7.50 0.00 632 1E51N055F 4/20/98 06-IC-1 E51-R-0001-04 Rosemount 1152GP6-N22 rnA 4.00 8.00 12.00 16.00 20.00 16.00 12.00 8.00 4.00

DRIFT ANALYSIS ENGINEERING DEPARTMENT GRAND GULF NUCLEAR STATION Rosemount Range Codes 5 - 8 Gage Pressure Transmitters Input Data JC-Q1111-09019 Rev. 0 Page 32 of 134 AF/AL Data Seq.

AF/

Pt1 Pt2 Pt 3 Pt4 Pt5 Pt6 Pt 7 PtB Pt9 Comments ID TaglD Date AL (0% Up)

(25% Up) (50% Up)

(75% Up)

(100%

(75% On) 1(50% On) (25% On)

(0% On) 1 1821N201A 6/17109 AF 4.020 8.010 12.000 16.000 19.990 16.000 12.010 8.010 4.020 2

1821N201A 6117/09 AL 4.020 8.010 12.000 16.000 19.990 16.000 12.010 8.010 4.020 3

1821N201A 8128107 AF 4.020 8.010 12.000 15.990 19.980 15.990 12.000 8.010 4.020 4

1821N201A 8128107 AL 4.020 8.010 12.000 15.990 19.980 15.990 12.000 8.010 4.020 5

1821N201A 11/8105 AF 3.980 8.020 12.050 16.100 20.210 16.120 12.050 8.030 3.980 6

1821N201A 1118/05 AL 4.010 8.000 12.000 16.000 20.000 16.000 12.000 8.000 4.010 7

1821N201A 5111/04 AF 4.010 8.020 12.030 16.040 20.050 16.040 12.030 8.020 4.020 8

1821N201A 5/11104 AL 3.980 7.990 12.000 16.010 20.020 16.010 12.000 7.990 3.990 9

1821N201A 11125/02 AF 4.010 8.010 12.010 16.010 20.020 16.020 12.020 8.010 4.010 10 1821N201A 11125102 AL 4.010 8.010 12.010 16.010 20.020 16.020 12.020 8.010 4.010 11 1821N201A 4124101 AF 4.070 8.000 11.990 15.980 19.980 16.000 12.000 8.000 4.070 12 1821N201A 4124/01 AL 4.020 7.980 11.990 16.000 20.010 16.000 11.990 7.970 4.030 13 1821N201A 10/28/99 AF 3.998 7.990 12.021 16.002 19.982 16.009 12.013 7.987 4.001 14 1821N201A 10128199 AL 3.998 7.990 12.021 16.002 19.982 16.009 12.013 7.987 4.001 15 1821N201A 4/21198 AF 4.010 8.000 12.000 15.990 19.990 15.990 12.000 8.000 4.010 16 1821N201A 4121/98 AL 4.010 8.000 12.000 15.990 19.990 15.990 12.000 8.000 4.010 17 1821N2018 1213110 AF 4.030 8.030 12.010 16.010 20.010 16.010 12.010 8.030 4.030 18 1821N2018 12/3/10 AL 4.030 8.030 12.010 16.010 20.010 16.010 12.010 8.030 4.030 19 1821N2018 3/31109 AF 4.020 8.020 12.010 16.010 20.010 16.010 12.010 8.020 4.020 20 1821N2018 3/31109 AL 4.020 8.020 12.010 16.010 20.010 16.010 12.010 8.020 4.020 21 1821N2018 10112107 AF 4.020 8.010 12.014 16.000 20.010 16.010 12.010 8.010 4.020 22 1821N2018 10/12107 AL 4.020 8.010 12.014 16.000 20.010 16.010 12.010 8.010 4.020

DRIFT ANALYSIS ENGINEERING DEPARTMENT GRAND GULF NUCLEAR STATION Rosemount Range Codes 5 - 8 Gage Pressure Transmitters Input Data JC-Q1111-09019 Rev. 0 Page 33 of 134 AF/AL Data Seq.

AF/

Pt 1 Pt2 Pt 3 Pt4 Pt5 Pt6 Pt7 Pt 8 Pt9 Comments 10 Tag 10 Date AL (0% Up) '(25% Up) (50% Up) (75% Up)

(100%

1(75% On) (50% On) 1(25% On)

(0% On) 23 1821N2018 3/8/06 AF 4.020 8.010 12.014 16.020 20.000 16.020 12.010 8.020 4.020 24 1821N2018 3/8/06 AL 4.020 8.010 12.014 16.020 20.000 16.020 12.010 8.020 4.020 25 1821N2018 7/15/04 AF 4.020 8.020 12.020 16.020 20.020 16.020 12.020 8.030 4.020 26 1821N2018 7/15/04 AL 4.020 8.020 12.020 16.020 20.020 16.020 12.020 8.030 4.020 27 1821N2018 10/24/02 AF 4.020 7.990 12.010 15.980 19.980 15.980 11.990 7.990 4.000 28 1821N2018 10/24/02 AL 4.020 7.990 12.010 15.980 19.980 15.980 11.990 7.990 4.000 29 1821N2018 4/23/01 AF 4.010 8.010 12.010 16.010 20.010 16.010 12.010 8.010 4.010 30 1821N2018 4/23/01 AL 4.010 8.010 12.010 16.010 20.010 16.010 12.010 8.010 4.010 31 1821N2018 11/5/99 AF 4.010 8.010 12.000 15.990 20.010 16.010 12.030 8.020 4.020 32 1821N2018 11/5/99 AL 4.010 8.010 12.000 15.990 20.010 16.010 12.030 8.020 4.020 33 1821N2018 4/16/98 AF 4.000 8.000 12.020 16.020 20.020 16.010 12.020 8.000 4.010 34 1821N2018 4/16/98 AL 4.000 8.000 12.020 16.020 20.020 16.010 12.020 8.000 4.010 35 1C61N102 8/12109 AF 4.000 7.990 11.990 16.000 19.990 16.000 11.990 8.000 4.000 36 1C61N102 8/12109 AL 4.000 7.990 11.990 16.000 19.990 16.000 11.990 8.000 4.000 37 1C61N102 2/15/08 AF 3.990 7.990 12.000 16.000 20.010 16.010 12.000 8.000 3.990 38 1C61N102 2/15/08 AL 3.990 7.990 12.000 16.000 20.010 16.010 12.000 8.000 3.990 39 1C61N102 8/31106 AF 3.970 7.970 11.980 15.990 20.000 16.000 11.990 7.970 3.970 40 1C61N102 8/31/06 AL 3.970 7.970 11.980 15.990 20.000 16.000 11.990 7.970 3.970 41 1C61N102 1/19/05 AF 3.960 7.960 11.960 15.970 19.980 15.970 11.970 7.960 3.960 42 1C61N102 1/19/05 AL 3.960 7.960 11.960 15.970 19.980 15.970 11.970 7.960 3.960 43 1C61N102 8/7/03 AF 4.000 7.990 11.990 15.990 19.990 15.990 12.000 8.000 4.000 44 1C61N102 8/7/03 AL 4.000 7.990 11.990 15.990 19.990 15.990 12.000 8.000 4.000

DRIFT ANALYSIS ENGINEERING DEPARTMENT GRAND GULF NUCLEAR STATION Rosemount Range Codes 5 - 8 Gage Pressure Transmitters Input Data JC-Q1111-09019 Rev. 0 Page 34 of 134 AF/AL Data Seq.

AF/

Pt 1 pt2 Pt3 pt4 pt5 PtG Pt7 ptS ptg Comments 10 Tag 10 Date AL (0% Up)

(25% Up)

I (50% Up) (75% Up)

(100%

1(75% On) !(50% On) 1(25% On)

(0% On) 45 1C61N102 2/8/02 AF 4.020 8.020 12.020 16.020 20.030 16.030 12.030 8.030 4.020 46 1C61N102 2/8/02 AL 4.000 8.000 12.000 16.000 20.000 16.000 12.000 8.000 4.000 47 1C61N102 8/15/00 AF 4.000 8.000 12.020 16.000 20.010 16.010 12.020 8.010 4.010 48 1C61N102 8/15/00 AL 4.000 8.000 12.020 16.000 20.010 16.010 12.020 8.010 4.010 49 1C61N102 3/29/99 AF 4.030 8.010 12.010 16.010 20.020 16.010 12.010 8.010 4.030 50 1C61N102 3/29/99 AL 4.030 8.010 12.010 16.010 20.020 16.010 12.010 8.010 4.030 51 1E12N053A 8/12/09 AF 4.190 8.000 12.000 16.000 20.000 16.000 12.010 8.010 4.180 52 1E12N053A 8/12/09 AL 4.190 8.000 12.000 16.000 20.000 16.000 12.010 8.010 4.180 53 1E12N053A 2/15/08 AF 4.130 7.960 11.950 15.950 19.950 15.960 11.960 7.960 4.150 54 1E12N053A 2/15/08 AL 4.190 8.000 11.990 15.990 19.990 16.000 12.000 8.000 4.190 55 1E12N053A 8/30/06 AF 4.150 7.970 11.980 15.970 19.970 15.980 11.970 7.970 4.160 56 1E12N053A 8/30/06 AL 4.150 7.970 11.980 15.970 19.970 15.980 11.970 7.970 4.160 57 1E12N053A 3/17/05 AF 4.150 7.970 11.960 15.960 19.960 15.970 11.970 7.980 4.160 58 1E12N053A 3/17/05 AL 4.150 7.970 11.960 15.960 19.960 15.970 11.970 7.980 4.160 59 1E12N053A 10/3/03 AF 4.150 7.970 11.970 15.970 19.970 15.980 11.980 7.980 4.150 60 1E12N053A 10/3/03 AL 4.150 7.970 11.970 15.970 19.970 15.980 11.980 7.980 4.150 61 1E12N053A 4/17/02 AF 4.160 8.000 12.000 16.000 20.000 16.010 12.010 8.000 4.160 62 1E12N053A 4/17/02 AL 4.160 8.000 12.000 16.000 20.000 16.010 12.010 8.000 4.160 63 1E12N053A 10/16/00 AF 4.170 7.990 12.010 16.000 20.010 16.000 12.010 7.990 4.170 64 1E12N053A 10/16/00 AL 4.170 7.990 12.010 16.000 20.010 16.000 12.010 7.990 4.170 65 1E12N053A 3/22/99 AF 4.150 7.980 12.010 15.990 20.040 16.010 12.010 7.980 4.160 66 1E12N053A 3/22/99 AL 4.160 7.990 12.010 16.010 19.990 16.000 12.000 7.980 4.160

DRIFT ANALYSIS ENGINEERING DEPARTMENT GRAND GULF NUCLEAR STATION Rosemount Range Codes 5 - 8 Gage Pressure Transmitters Input Data JC-Q1111-09019 Rev. 0 Page 35 of 134 AF/AL Data Seq.

AFJ pt1 Pt2 Pt 3 pt4 pt5 Pt6 Pt 7 pt8 Pt9 Comments 10 Tag 10 Oate AL (0"10 Up)

(25"10 Up)

(50"10 Up)

(75"10 Up)

(100"10 (75"10 On) 1(50"10 On) (25"10 On)

(0"10 On) 67 1E12N053A 8/26/97 AF 4.169 7.990 12.010 16.008 20.012 16.011 12.013 7.995 4.169 68 1E12N053A 8/26/97 AL 4.169 7.990 12.010 16.008 20.012 16.011 12.013 7.995 4.169 69 1E12N0538 12/14/09 AF 4.140 8.000 11.990 15.990 19.990 15.990 12.000 8.010 4.150 70 1E12N0538 12/14/09 AL 4.140 8.000 11.990 15.990 19.990 15.990 12.000 8.010 4.150 71 1E12N0538 5/29/08 AF 4.160 8.010 12.000 16.000 20.000 16.020 12.010 8.020 4.200 72 1E12N0538 5/29/08 AL 4.160 8.010 12.000 16.000 20.000 16.020 12.010 8.020 4.200 73 1E12N0538 11/29/06 AF 4.160 7.970 11.960 15.950 19.950 15.950 11.960 7.970 4.160 74 1E12N0538 11/29/06 AL 4.200 8.000 11.990 15.990 19.980 16.000 12.000 8.010 4.200 75 1E12N0538 5/20/05 AF 4.160 7.970 11.970 15.970 19.970 15.980 11.980 7.980 4.160 76 1E12N0538 5/20/05 AL 4.160 7.970 11.970 15.970 19.970 15.980 11.980 7.980 4.160 77 1E12N0538 11/20/03 AF 4.160 7.970 11.960 15.970 19.970 15.980 11.980 7.990 4.160 78 1E12N0538 11/20/03 AL 4.160 7.970 11.960 15.970 19.970 15.980 11.980 7.990 4.160 79 1E12N0538 7/17/02 AF 4.180 7.990 11.980 15.980 19.980 15.990 12.000 8.000 4.190 80 1E12N0538 7/17/02 AL 4.180 7.990 11.980 15.980 19.980 15.990 12.000 8.000 4.190 81 1E12N0538 9/28/00 AF 4.180 7.980 12.000 16.000 19.980 16.000 11.990 7.990 4.180 82 1E12N0538 9/28/00 AL 4.180 7.980 12.000 16.000 19.980 16.000 11.990 7.990 4.180 83 1E12N0538 3/18/99 AF 4.160 8.000 11.990 16.000 19.990 16.010 12.010 8.010 4.150 84 1E12N0538 3/18/99 AL 4.160 8.000 11.990 16.000 19.990 16.010 12.010 8.010 4.150 85 1E12N0538 8/20/97 AF 4.176 8.006 12.021 16.013 20.038 16.029 12.025 8.017 4.181 86 1E12N0538 8/20/97 AL 4.176 8.006 12.021 16.013 20.038 16.029 12.025 8.017 4.181 87 1E12N053C 11/4/10 AF 4.020 7.980 11.980 15.980 19.980 15.990 11.990 7.990 4.030 88 1E12N053C 11/4/10 AL 4.020 7.980 11.980 15.980 19.980 15.990 11.990 7.990 4.030

DRIFT ANALYSIS ENGINEERING DEPARTMENT GRAND GULF NUCLEAR STATION Rosemount Range Codes 5 - 8 Gage Pressure Transmitters Input Data JC-Q1111-09019 Rev. 0 Page 36 of 134 AF/AL Data Seq.

AFI Pt1 Pt2 Pt3 Pt4 Pt 5 Pt6 Pt7 PtS Ptg Comments 10 Tag 10 Date AL (0% Up)

(25% Up) (50% Up) (75% Up)

(100%

(75% On).(50% On) (25% On)

(0% On) 89 1E12N053C 5/11/09 AF 4.030 7.990 12.000 15.990 19.990 16.000 12.010 8.000 4.030 90 1E12N053C 5/11/09 AL 4.030 7.990 12.000 15.990 19.990 16.000 12.010 8.000 4.030 91 1E12N053C 9/17/07 AF 4.020 7.970 11.970 15.970 19.970 15.990 11.990 7.990 4.030 92 1E12N053C 9/17/07 AL 4.020 7.970 11.970 15.970 19.970 15.990 11.990 7.990 4.030 93 1E12N053C 1/23/06 AF 4.050 7.990 11.980 15.980 19.980 15.990 12.000 8.000 4.050 94 1E12N053C 1/23/06 AL 4.050 7.990 11.980 15.980 19.980 15.990 12.000 8.000 4.050 95 1E12N053C 4/7/04 AF 4.040 7.990 11.990 15.990 19.980 16.000 12.000 8.000 4.040 96 1E12N053C 4/7/04 AL 4.040 7.990 11.990 15.990 19.980 16.000 12.000 8.000 4.040 97 1E12N053C 7/17/02 AF 4.040 8.000 12.000 16.000 19.990 16.010 12.010 8.010 4.040 98 1E12N053C 7/17/02 AL 4.040 8.000 12.000 16.000 19.990 16.010 12.010 8.010 4.040 99 1E12N053C 10/24/00 AF 4.040 7.990 11.990 15.970 19.990 16.000 11.990 7.990 4.040 100 1E12N053C 10/24/00 AL 4.040 7.990 11.990 15.970 19.990 16.000 11.990 7.990 4.040 101 1E12N053C 3/18/99 AF 4.040 8.000 12.000 16.000 19.990 16.010 12.010 8.020 4.040 102 1E12N053C 3/18/99 AL 4.040 8.000 12.000 16.000 19.990 16.010 12.010 8.020 4.040 103 1E12N053C 8/20/97 AF 4.053 8.021 11.998 16.022 20.010 15.984 12.030 8.011 4.058 104 1E12N053C 8/20/97 AL 4.053 8.021 11.998 16.022 20.010 15.984 12.030 8.011 4.058 105 1E12N055A 12/22/09 AF 4.340 8.020 12.010 16.020 20.030 16.020 12.010 8.020 4.340 106 1E12N055A 12/22/09 AL 4.340 8.020 12.010 16.020 20.030 16.020 12.010 8.020 4.340 107 1E12N055A 6/30/08 AF 4.320 7.990 11.980 15.990 20.020 15.990 11.990 7.990 4.320 108 1E12N055A 6/30/08 AL 4.320 7.990 11.980 15.990 20.020 15.990 11.990 7.990 4.320 109 1E12N055A 9/14/06 AF 4.330 8.000 11.990 16.010 20.030 16.010 12.000 8.010 4.330 110 1E12N055A 9/14/06 AL 4.330 8.000 11.990 16.010 20.030 16.010 12.000 8.010 4.330

DRIFT ANALYSIS ENGINEERING DEPARTMENT GRAND GULF NUCLEAR STATION Rosemount Range Codes 5 - 8 Gage Pressure Transmitters Input Data JC-Q1111-09019 Rev. 0 Page 37 of 134 AF/AL Data Seq.

AFI pt1 Pt2 Pt3 pt4 pt5 Pt6 Pt7 pta Pt9 Comments 10 Tag 10 Oate AL (0% Up)

(25% Up)

(50% Up)

(75% Up)

(100%

(75% On) (50% On) (25% On)

(0% On) 111 1E12N055A 1/17/05 AF 4.290 7.960 11.950 15.940 19.970 15.950 11.950 7.960 4.300 112 1E12N055A 1/17/05 AL 4.330 7.990 11.990 15.990 20.020 15.990 11.990 8.000 4.330 113 1E12N055A 9/3/03 AF 4.300 7.980 11.970 15.980 19.990 15.980 11.980 7.980 4.290 114 1E12N055A 9/3/03 AL 4.300 7.980 11.970 15.980 19.990 15.980 11.980 7.980 4.290 115 1E12N055A 3/8/02 AF 4.290 8.030 11.990 16.020 20.030 15.990 11.990 8.030 4.290 116 1E12N055A 3/8/02 AL 4.310 7.990 11.990 15.990 20.010 15.990 11.990 8.000 4.310 117 1E12N055A 10/4/00 AF 4.330 8.020 12.030 16.040 20.070 16.030 12.040 8.050 4.330 118 1E12N055A 10/4/00 AL 4.300 8.010 11.990 16.000 20.000 16.000 12.010 8.010 4.310 119 1E12N055A 4/11/99 AF 4.343 8.015 12.000 15.993 20.026 15.985 12.003 7.985 4.339 120 1E12N055A 4/11/99 AL 4.343 8.015 12.000 15.993 20.026 15.985 12.003 7.985 4.339 121 1E12N055A 8/30/97 AF 4.334 8.015 11.992 15.988 20.010 15.981 12.011 8.022 4.337 122 1E12N055A 8/30/97 AL 4.334 8.015 11.992 15.988 20.010 15.981 12.011 8.022 4.337 123 1E12N0558 1/21/10 AF 4.330 8.000 11.980 15.980 19.990 15.980 11.980 8.000 4.330 124 1E12N0558 1/21/10 AL 4.330 8.000 11.980 15.980 19.990 15.980 11.980 8.000 4.330 125 1E12N0558 5/29/08 AF 4.330 7.980 11.960 15.970 20.000 15.970 11.960 7.980 4.330 126 1E12N0558 5/29/08 AL 4.330 7.980 11.960 15.970 20.000 15.970 11.960 7.980 4.330 127 1E12N0558 11/29/06 AF 4.320 7.940 11.930 15.930 19.940 15.930 11.930 7.950 4.320 128 1E12N0558 11/29/06 AL 4.340 7.990 11.970 15.990 20.010 15.990 11.970 7.990 4.340 129 1E12N0558 5/20/05 AF 4.340 7.980 11.960 15.970 19.980 15.970 11.970 7.990 4.340 130 1E12N0558 5/20/05 AL 4.340 7.980 11.960 15.970 19.980 15.970 11.970 7.990 4.340 131 1E12N0558 11/19/03 AF 4.340 7.970 11.950 15.950 19.980 15.960 11.960 7.970 4.330 132 1E12N0558 11/19/03 AL 4.350 7.990 11.970 15.980 20.000 15.980 11.970 7.990 4.350

DRIFT ANALYSIS ENGINEERING DEPARTMENT GRAND GULF NUCLEAR STATION Rosemount Range Codes 5 - 8 Gage Pressure Transmitters Input Data JC-Q1111-09019 Rev. 0 Page 38 of 134 AF/AL Data Seq.

AFI pt1 Pt2 Pt3 pt4 pt5 Pt6 Pt7 Pt8 Ptg Comments 10 Tag 10 Oate AL (0% Up)

(25% Up) (50% Up) (75% Up)

(100%

(75% On) 1(50% On) (25% On)

(0% On) 133 1E12N055B 6/4/02 AF 4.320 7.980 11.990 15.980 19.940 15,990 12.000 7.990 4.320 Transmitter electronics replaced per MAl 300796.

134 1E12N055B 6/4/02 AL 4.330 8.000 11.990 16.000 20.020 16.000 11.990 8.000 4.330 135 1E12N055B 12/5/00 AF 4.320 7.990 11.980 16.000 19.990 15.990 11.980 7.980 4.320 136 1E12N055B 12/5/00 AL 4.320 7.990 11.980 16.000 19.990 15.990 11.980 7.980 4.320 137 1E12N055B 5/26/99 AF 4.320 8.000 12.016 16.017 19.969 16.035 12.017 8.019 4.321 138 1E12N055B 5/26/99 AL 4.320 8.000 12.016 16.017 19.969 16.035 12.017 8.019 4.321 139 1E12N055B 10/16/97 AF 4.300 7.990 11.990 15.990 20.000 15.990 12.000 7.980 4.310 140 1E12N055B 10/16/97 AL 4.300 7.990 11.990 15.990 20.000 15.990 12.000 7.980 4.310

DRIFT ANALYSIS ENGINEERING DEPARTMENT GRAND GULF NUCLEAR STATION Rosemount Range Codes 5 - 8 Gage Pressure Transmitters Input Data JC-Q1111-09019 Rev. 0 Page 39 of 134 AF/AL Data Seq.

AF/

Pt 1 Pt2 Pt3 Pt4 Pt5 Pt 6 Pt 7 Pt 8 Pt9 Comments 10 Tag 10 Date AL (0% Up)

(25% Up) (50% Up) 1175% Up)

(100%

(75% On) (50% On) 1(25% On)

(0% On) 141 1E12N055C 1/20/10 AF 4.070 8.030 12.020 16.020 20.020 16.020 12.020 8.030 4.070 142 1E12N055C 1/20/10 AL 4.070 8.030 12.020 16.020 20.020 16.020 12.020 8.030 4.070 143 1E12N055C 5/29/08 AF 4.070 8.010 12.000 16.000 20.000 16.000 12.000 8.010 4.070 144 1E12N055C 5/29/08 AL 4.070 8.010 12.000 16.000 20.000 16.000 12.000 8.000 4.070 145 1E12N055C 11/29/06 AF 3.990 7.960 11.940 15.920 19.930 15.920 11.930 7.980 4.000 146 1E12N055C 11/29/06 AL 4.040 8.020 12.010 16.000 20.000 16.000 12.010 8.020 4.040 147 1E12N055C 5/20/05 AF 4.070 8.010 12.000 15.990 19.990 15.990 12.000 8.010 4.070 148 1E12N055C 5/20/05 AL 4.070 8.010 12.000 15.990 19.990 15.990 12.000 8.010 4.070 149 1E12N055C 11/19/03 AF 4.080 8.010 12.000 16.000 20.000 16.000 12.010 8.020 4.080 150 1E12N055C 11/19/03 AL 4.080 8.010 12.000 16.000 20.000 16.000 12.010 8.020 4.080 151 1E12N055C 7/3/02 AF 4.050 7.980 11.970 15.970 19.960 15.970 11.970 7.980 4.040 152 1E12N055C 7/3/02 AL 4.070 8.010 12.000 15.990 19.970 15.990 12.000 8.010 4.070 153 1E12N055C 1216/00 AF 4.050 7.990 11.990 15.980 19.970 15.980 11.980 7.990 4.050 154 1E12N055C 1216/00 AL 4.050 7.990 11.990 15.980 19.970 15.980 11.980 7.990 4.050 155 1E12N055C 5/27/99 AF 4.060 8.010 12.020 16.000 19.990 16.010 12.040 8.010 4.050 156 1E12N055C 5/27/99 AL 4.060 8.010 12.020 16.000 19.990 16.010 12.040 8.010 4.050 157 1E12N055C 10/16/97 AF 4.050 7.980 11.960 15.960 19.970 15.960 11.970 7.970 4.050 158 1E12N055C 10/16/97 AL 4.050 7.980 11.960 15.960 19.970 15.960 11.970 7.970 4.050 159 1E12N056A 12/21/09 AF 4.330 8.020 12.030 16.040 20.030 16.040 12.030 8.020 4.330 160 1E12N056A 12/21/09 AL 4.310 8.000 12.000 16.000 20.000 16.000 12.000 8.000 4.310

DRIFT ANALYSIS ENGINEERING DEPARTMENT GRAND GULF NUCLEAR STATION Rosemount Range Codes 5 - 8 Gage Pressure Transmitters Input Data JC-Q1111-09019 Rev. 0 Page 40 of 134 AF/AL Data Seq.

AFI Pt 1 Pt 2 Pt 3 Pt4 Pt5 Pt6 Pt7 Pt8 Pt9 Comments 10 Tag 10 Date AL (0% Up)

(25% Up)

(50% Up)

(75% Up)

(100%

(75% On) (50% On) 1(25% On)

(0% On) 161 1E12N056A 6/30/08 AF 4.240 7.940 11.950 15.950 19.950 15.950 11.950 7.940 4.240 162 1E12N056A 6/30/08 AL 4.310 8.000 12.010 16.020 20.010 16.020 12.020 8.000 4.310 163 1E12N056A 9/15/06 AF 4.290 7.990 12.000 16.000 20.000 16.000 12.000 7.990 4.280 164 1E12N056A 9/15/06 AL 4.290 7.990 12.000 16.000 20.000 16.000 12.000 7.990 4.280 165 1E12N056A 1/17/05 AF 4.310 7.980 11.990 15.980 20.000 15.990 12.000 7.990 4.300 166 1E12N056A 1/17/05 AL 4.310 7.980 11.990 15.980 20.000 15.990 12.000 7.990 4.300 167 1E12N056A 8/6/03 AF 4.300 7.980 12.000 16.000 20.010 16.010 12.010 7.980 4.300 168 1E12N056A 8/6/03 AL 4.300 7.980 12.000 16.000 20.010 16.010 12.010 7.980 4.300 169 1E12N056A 2/8/02 AF 4.300 7.940 11.910 15.900 19.940 15.900 11.900 7.920 4.290 170 1E12N056A 2/8/02 AL 4.310 8.000 11.990 16.010 20.000 16.010 11.990 7.990 4.310 171 1E12N056A 10/4/00 AF 4.290 8.000 11.990 16.000 20.030 16.010 12.010 7.990 4.300 172 1E12N056A 10/4/00 AL 4.290 8.000 11.990 16.000 20.030 16.010 12.010 7.990 4.300 173 1E12N056A 4/11/99 AF 4.285 7.982 11.980 15.977 20.001 15.975 11.981 7.976 4.301 174 1E12N056A 4/11/99 AL 4.285 7.982 11.980 15.977 20.001 15.975 11.981 7.976 4.301 175 1E12N056A 8/30/97 AF 4.335 7.976 11.970 15.951 20.007 15.948 11.957 8.006 4.344 176 1E12N056A 8/30/97 AL 4.304 7.988 11.976 15.974 20.009 15.971 11.976 7.987 4.304 177 1E12N056B 2/5/10 AF 4.350 8.030 12.010 16.010 20.020 16.020 12.020 8.030 4.340 178 1E12N056B 2/5/10 AL 4.350 8.030 12.010 16.010 20.020 16.020 12.020 8.030 4.340 179 1E12N056B 7/8/08 AF 4.270 7.910 11.900 15.900 19.940 15.900 11.900 7.910 4.270 180 1E12N056B 7/8/08 AL 4.320 7.970 11.960 15.970 19.990 15.970 11.960 7.970 4.320

DRIFT ANALYSIS ENGINEERING DEPARTMENT GRAND GULF NUCLEAR STATION Rosemount Range Codes 5 - 8 Gage Pressure Transmitters Input Data JC-Q1111-09019 Rev. 0 Page 41 of 134 AF/AL Data Seq.

AFI Pt1 Pt2 Pt3 Pt4 Pt5 Pt6 Pt7 Pt8 Pt9 Comments 10 TaalO Date AL (0% Up)

(25% Up) (50% Up) (75% Up)

(100%

1(75% On) 1(50% On) 1(25% On)

(0% On) 181 1E12N0568 1/11/07 AF 4.320 7.990 11.980 15.980 19.990 15.990 11.980 7.980 4.330 182 1E12N0568 1/11/07 AL 4.320 7.990 11.980 15.980 19.990 15.990 11.980 7.980 4.330 183 1E12N0568 7114/05 AF 4.330 7.990 11.990 15.990 20.030 15.990 11.990 7.990 4.330 184 1E12N0568 7/14/05 AL 4.330 7.990 11.990 15.990 20.030 15.990 11.990 7.990 4.330 185 1E12N0568 10/22/03 AF 4.300 7.920 11.980 15.860 19.870 15.860 11.880 7.920 4.300 186 1E12N0568 10/22/03 AL 4.320 7.990 11.970 15.970 20.010 15.970 11.970 7.990 4.320 187 1E12N0568 4/23/02 AF 4.340 8.030 12.050 16.080 20.100 16.080 12.050 8.070 4.360 Transmitter electronics replaced per MAl 308619.

188 1E12N0568 4/23/02 AL 4.320 8.010 11.980 15.980 20.010 15.990 11.990 8.000 4.320 189 1E12N0568 1216/00 AF 4.350 8.010 12.000 15.970 20.010 15.980 12.010 8.010 4.350 190 1E12N0568 1216/00 AL 4.350 8.010 12.000 15.970 20.010 15.980 12.010 8.010 4.350 191 1E12N0568 5/26/99 AF 4.343 8.023 12.024 16.026 20.025 16.022 12.022 8.004 4.359 192 1E12N0568 5/26/99 AL 4.343 8.023 12.024 16.026 20.025 16.022 12.022 8.004 4.359 193 1E12N0568 10/16/97 AF 4.350 8.040 12.060 16.090 20.150 16.090 12.070 8.060 4.350 194 1E12N0568 10/16/97 AL 4.350 7.990 11.980 15.990 20.040 16.000 11.970 7.990 4.350 195 1E12N056C 4/6/10 AF 4.000 7.930 11.930 15.930 19.930 15.920 11.930 7.920 3.990 196 1E12N056C 4/6/10 AL 4.020 7.980 11.990 16.000 20.020 16.000 11.990 7.980 4.020 197 1E12N056C 7/8/08 AF 4.050 8.000 12.000 16.000 20.020 16.000 12.000 8.000 4.050 198 1E12N056C 7/8/08 AL 4.050 8.000 12.000 16.000 20.020 16.000 12.000 8.000 4.050 199 1E12N056C 1/10/07 AF 4.060 8.000 12.000 16.000 20.000 16.000 12.010 8.000 4.050 200 1E12N056C 1/10/07 AL 4.060 8.000 12.000 16.000 20.000 16.000 12.010 8.000 4.050

DRIFT ANALYSIS ENGINEERING DEPARTMENT GRAND GULF NUCLEAR STATION Rosemount Range Codes 5 - 8 Gage Pressure Transmitters Input Data JC-Q1111-09019 Rev. 0 Page 42 of 134 AF/AL Data Seq.

AFI Pt 1 Pt 2 Pt 3 Pt4 Pt5 Pt6 Pt7 PtS Pt9 Comments 10 Tag 10 Date AL (0% Up).(25% Up) (50% Up) (75% Up)

(100%

1(75% On) 1(50% On) 1(25% On)

(0% On) 201 1E12N056C 6/29/05 AF 4.050 8.000 11.970 15.950 19.940 15.950 11.960 7.980 4.050 202 1E12N056C 6/29/05 AL 4.050 7.990 11.990 15.970 19.990 15.970 11.990 7.990 4.050 203 1E12N056C 10/22103 AF 4.050 8.000 11.990 15.980 19.980 15.980 11.990 8.000 4.050 204 1E12N056C 10/22/03 AL 4.050 8.000 11.990 15.980 19.980 15.980 11.990 8.000 4.050 205 1E12N056C 7/3/02 AF 4.040 7.980 11.980 15.970 19.970 15.970 11.980 8.000 4.040 206 1E12N056C 7/3/02 AL 4.040 7.980 11.980 15.970 19.970 15.970 11.980 8.000 4.040 207 1E12N056C 12/6/00 AF 4.050 7.990 11.950 15.960 19.950 15.950 11.970 8.000 4.050 208 1E12N056C 12/6/00 AL 4.060 8.010 11.990 15.990 19.990 15.990 12.000 8.010 4.060 209 1E12N056C 5/26/99 AF 4.014 8.004 12.031 15.985 19.991 16.011 12.037 8.019 4.035 210 1E12N056C 5/26/99 AL 4.014 8.004 12.031 15.985 19.991 16.011 12.037 8.019 4.035 211 1E12N056C 10/16/97 AF 4.050 8.010 11.970 15.970 19.980 15.970 11.970 7.990 4.050 212 1E12N056C 10/16/97 AL 4.050 8.010 11.970 15.970 19.980 15.970 11.970 7.990 4.050 213 1E12N057 2/9/10 AF 3.990 7.990 12.000 15.990 19.990 15.990 12.000 8.000 3.990 214 1E12N057 219/10 AL 3.990 7.990 12.000 15.990 19.990 15.990 12.000 8.000 3.990 215 1E12N057 4/25/08 AF 3.990 8.000 12.000 16.000 20.000 16.010 12.010 8.010 4.000 216 1E12N057 4/25/08 AL 3.990 8.000 12.000 16.000 20.000 16.010 12.010 8.010 4.000 217 1E12N057 7/19/06 AF 4.000 8.000 11.990 15.990 19.990 16.000 11.990 8.000 4.000 218 1E12N057 7/19/06 AL 4.000 8.000 11.990 15.990 19.990 16.000 11.990 8.000 4.000 219 1E12N057 1/20105 AF 4.000 8.000 12.000 16.000 20.000 16.010 12.020 8.010 4.000 220 1E12N057 1/20105 AL 4.000 8.000 12.000 16.000 20.000 16.010 12.020 8.010 4.000 221 1E12N057 8/8/03 AF 4.000 7.980 11.980 15.980 19.990 16.000 12.000 7.990 3.990 222 1E12N057 8/8/03 AL 4.000 7.980 11.980 15.980 19.990 16.000 12.000 7.990 3.990

DRIFT ANALYSIS ENGINEERING DEPARTMENT GRAND GULF NUCLEAR STATION Rosemount Range Codes 5 - 8 Gage Pressure Transmitters Input Data JC-Q1111-09019 Rev. 0 Page 43 of 134 AF/AL Data Seq.

AFI Pt 1 Pt 2 Pt3 Pt4 Pt5 Pt6 Pt 7 PtS Pt 9 Comments 10 Tag 10 Date AL (0% Up)

(25% Up)

(50% Up)

(75% Up)

(100%

1(75% On) (50% On) (25% On)

(0% On) 223 1E12N057 2/20102 AF 4.000 7.990 12.000 15.990 20.000 15.990 12.020 8.000 4.000 224 1E12N057 2/20102 AL 4.000 7.990 12.000 15.990 20.000 15.990 12.020 8.000 4.000 225 1E12N057 218/01 AF 3.970 7.960 11.960 15.950 19.940 15.970 11.960 7.970 3.970 226 1E12N057 2/8/01 AL 4.000 7.990 11.990 15.990 19.990 16.000 12.000 8.000 4.000 227 1E12N057 8/1/99 AF 3.990 7.990 11.980 15.990 19.980 16.000 12.010 8.000 4.000 228 1E12N057 8/1/99 AL 3.990 7.990 11.980 15.990 19.980 16.000 12.010 8.000 4.000 229 1E12N057 1/27/98 AF 4.025 8.070 12.090 16.090 20.071 16.075 12.093 8.091 4.055 230 1E12N057 1/27/98 AL 4.014 8.004 12.013 16.016 20.002 16.020 12.023 8.008 3.998 231 1E12N058A 7/12/10 AF 3.990 7.980 11.980 15.990 19.990 16.000 11.990 7.990 3.990 232 1E12N058A 7/12/10 AL 3.990 7.980 11.980 15.990 19.990 16.000 11.990 7.990 3.990 233 1E12N058A 9/10108 AF 4.000 8.000 12.000 16.000 20.000 16.000 12.020 8.010 4.000 234 1E12N058A 9/10108 AL 4.000 8.000 12.000 16.000 20.000 16.000 12.020 8.010 4.000 235 1E12N058A 1/16/07 AF 3.990 8.000 11.990 16.000 20.000 16.000 12.000 8.010 3.990 236 1E12N058A 1/16/07 AL 3.990 8.000 11.990 16.000 20.000 16.000 12.000 8.010 3.990 237 1E12N058A 7/22/05 AF 3.990 8.000 12.000 16.000 20.000 15.990 12.000 7.990 4.000 238 1E12N058A 7/22/05 AL 3.990 8.000 12.000 16.000 20.000 15.990 12.000 7.990 4.000 239 1E12N058A 1/9/04 AF 4.010 7.990 11.970 15.960 19.940 15.970 11.980 7.990 4.010 240 1E12N058A 1/9/04 AL 4.000 8.000 12.000 15.990 20.000 15.990 12.000 8.000 4.000 AF Pt 5 recorded as 22.06. This value is not compatible with a functioning transmitter or 241 1E12N058A 9/9/02 AF 4.020 8.040 12.030 16.030 EXC 16.030 12.030 8.040 4.020 consistent with other AF data points. Correct value is probably 20.06. Data point excluded as erroneous.

242 1E12N058A 9/9/02 AL 4.010 8.010 12.000 16.010 20.000 16.010 11.990 8.020 4.010 243 1E12N058A 1/23/01 AF 4.030 8.020 12.020 16.020 20.030 16.020 12.030 8.030 4.030

DRIFT ANALYSIS ENGINEERING DEPARTMENT GRAND GULF NUCLEAR STATION Rosemount Range Codes 5 - 8 Gage Pressure Transmitters Input Data JC-Q1111-09019 Rev. 0 Page 44 of 134 AF/AL Data Seq.

AFI pt1 pt2 Pt 3 pt4 Pt 5 Pt6 Pt7 pta Pt 9 Comments 10 Tag 10 Oate AL (0% Up)

(25% Up) (50% Up) (75% Up)

(100%

1(75% On) (50% On) (25% On)

(0% On) 244 1E12N058A 1/23/01 AL 4.030 8.020 12.020 16.020 20.030 16.020 12.030 8.030 4.030 245 1E12N058A 9/22/99 AF 3.930 7.970 11.970 15.970 19.960 15.970 11.980 7.970 3.950 246 1E12N058A 9/22/99 AL 4.010 8.020 12.010 16.020 20.000 16.010 12.020 8.020 4.010 247 1E12N058A 1/28/98 AF 3.980 7.980 11.980 16.000 20.000 15.990 12.000 7.990 4.000 248 1E12N058A 1/28/98 AL 3.980 7.980 11.980 16.000 20.000 15.990 12.000 7.990 4.000 249 1E12N0588 2/19/10 AF 4.000 7.970 11.960 15.970 19.990 15.980 11.970 7.960 4.000 250 1E12N0588 2119/10 AL 4.000 7.970 11.960 15.970 19.990 15.980 11.970 7.960 4.000 251 1E12N0588 7/10/08 AF 4.010 8.020 12.010 16.010 20.020 16.020 12.030 8.040 4.050 252 1E12N0588 7/10/08 AL 4.000 7.990 11.990 15.990 20.000 16.000 12.000 8.000 4.000 253 1E12N0588 1/10/07 AF 4.030 8.020 12.020 16.010 20.010 16.020 12.020 8.020 4.030 254 1E12N0588 1/10/07 AL 4.030 8.020 12.020 16.010 20.010 16.020 12.020 8.020 4.030 255 1E12N0588 6/29/05 AF 4.030 8.000 11.990 15.990 19.990 16.000 12.000 8.010 4.030 256 1E12N0588 6/29/05 AL 4.030 8.000 11.990 15.990 19.990 16.000 12.000 8.010 4.030 257 1E12N0588 1/14/04 AF 4.010 8.000 12.000 16.000 20.000 16.020 12.030 8.030 4.030 258 1E12N0588 1114/04 AL 4.010 8.000 12.000 16.000 20.000 16.020 12.030 8.030 4.030 259 1E12N0588 7/18/02 AF 4.000 7.990 11.990 16.000 19.990 15.990 12.010 8.010 4.010 260 1E12N0588 7/18/02 AL 4.000 7.990 11.990 16.000 19.990 15.990 12.010 8.010 4.010 261 1E12N0588 1/29/01 AF 4.030 8.000 11.980 15.980 20.020 16.000 11.990 8.010 4.030 262 1E12N0588 1/29/01 AL 4.030 8.000 11.980 15.980 20.020 16.000 11.990 8.010 4.030 263 1E12N0588 8/19/99 AF 4.034 8.028 12.026 16.017 20.016 16.018 12.024 8.026 4.030 264 1E12N0588 8/19/99 AL 4.034 8.028 12.026 16.017 20.016 16.018 12.024 8.026 4.030 265 1E12N0588 1/5/98 AF 3.990 8.020 12.020 16.070 20.060 16.080 12.060 8.020 4.030

DRIFT ANALYSIS ENGINEERING DEPARTMENT GRAND GULF NUCLEAR STATION Rosemount Range Codes 5 - 8 Gage Pressure Transmitters Input Data JC-Q1111-09019 Rev. 0 Page 45 of 134 AF/AL Data Seq.

AF/

Pt 1 Pt2 Pt3 Pt4 Pt5 Pt6 Pt 7 PtS Pt 9 Comments 10 Tag 10 Oate AL (0% Up)

(25% Up) (50% Up) (75% Up)

(100%

1(75% On) *(50% On) 1(25% On)

(0% On) 266 1E12N058B 1/5/98 Al 4.000 8.000 12.000 16.000 19.990 16.010 12.010 8.010 4.010 267 1E12N058C 2/16/10 AF 3.960 7.960 11.950 15.960 19.950 15.960 11.970 7.970 3.970 268 1E12N058C 2/16/10 Al 4.020 8.020 12.010 16.000 20.000 16.010 12.020 8.020 4.020 269 1E12N058C 6/24/08 AF 4.000 7.980 11.970 15.960 19.960 15.970 11.970 7.980 4.000 270 1E12N058C 6/24/08 Al 4.000 7.990 11.980 15.980 19.990 15.980 11.990 8.010 4.000 271 1E12N058C 12/2106 AF 4.030 8.000 11.990 16.000 20.000 16.000 12.010 8.020 4.040 272 1E12N058C 12/2/06 Al 4.030 8.000 11.990 16.000 20.000 16.000 12.010 8.020 4.040 273 1E12N058C 5/19/05 AF 4.020 8.000 11.980 15.980 19.990 16.000 12.010 8.010 4.020 274 1E12N058C 5/19/05 Al 4.020 8.000 11.980 15.980 19.990 16.000 12.010 8.010 4.020 275 1E12N058C 10/23/03 AF 4.010 7.990 11.980 15.970 19.980 16.000 12.000 8.010 4.020 276 1E12N058C 10/23/03 Al 4.010 7.990 11.980 15.970 19.980 16.000 12.000 8.010 4.020 277 1E12N058C 7/18/02 AF 3.960 7.960 11.960 15.960 19.960 15.960 11.960 7.960 3.970 278 1E12N058C 7/18/02 Al 4.010 8.000 11.990 15.990 19.990 15.990 11.990 7.990 4.000 279 1E12N058C 1/29/01 AF 3.980 7.980 11.970 15.990 20.020 16.000 12.010 8.000 3.990 280 1E12N058C 1/29/01 Al 3.980 7.980 11.970 15.990 20.020 16.000 12.010 8.000 3.990 281 1E12N058C 9/2199 AF 4.040 8.060 12.080 16.100 20.100 16.080 12.120 8.050 4.020 282 1E12N058C 9/2/99 Al 3.980 8.010 12.010 16.010 20.030 16.020 12.030 8.010 3.990 283 1E12N058C 2/21/98 AF 3.970 7.990 11.920 15.930 19.940 15.960 11.940 7.980 3.970 284 1E12N058C 2/21/98 Al 4.010 7.980 11.980 16.000 20.000 16.000 11.980 7.980 4.010 285 1E21N050 8/27/10 AF 3.990 7.990 11.980 15.990 19.990 15.990 11.990 8.000 3.990 286 1E21N050 8/27/10 Al 3.990 7.990 11.980 15.990 19.990 15.990 11.990 8.000 3.990 287 1E21N050 11/20/08 AF 3.990 7.980 11.980 15.990 19.980 15.990 12.000 8.010 4.010

DRIFT ANALYSIS ENGINEERING DEPARTMENT GRAND GULF NUCLEAR STATION Rosemount Range Codes 5 - 8 Gage Pressure Transmitters Input Data JC-Q1111-09019 Rev. 0 Page 46 of 134 AF/AL Data Seq.

AFI Pt 1 Pt2 Pt 3 Pt4 Pt5 Pt 6 Pt7 PtS Ptg Comments ID TaglD Date AL (0"10 Up)

(25"10 Up)

(50"10 Up)

(75"10 Up)

(100"10 (75"10 Dn) (50"10 Dn) (25"10 Dn)

(O"loDn) 288 1E21N050 11/20108 AL 3.990 7.980 11.980 15.990 19.980 15.990 12.000 8.010 4.010 289 1E21N050 5/11/07 AF 3.980 7.970 11.970 15.970 19.980 15.980 12.000 7.980 3.990 290 1E21N050 5/11/07 AL 3.980 7.970 11.970 15.970 19.980 15.980 12.000 7.980 3.990 291 1E21N050 7118/05 AF 3.990 7.980 11.990 16.000 20.000 16.000 11.990 7.990 4.010 292 1E21N050 7118/05 AL 3.990 7.980 11.990 16.000 20.000 16.000 11.990 7.990 4.010 293 1E21N050 10/14/03 AF 3.990 7.990 11.980 15.990 19.990 16.000 12.000 7.990 4.000 294 1E21N050 10/14/03 AL 3.990 7.990 11.980 15.990 19.990 16.000 12.000 7.990 4.000 295 1E21N050 4/18/02 AF 3.970 7.950 11.950 15.960 19.970 15.980 11.960 7.970 3.960 296 1E21N050 4/18/02 AL 4.000 8.000 11.980 15.990 20.020 16.000 11.990 7.990 4.000 297 1E21N050 10/16/00 AF 3.990 7.990 11.980 15.980 20.000 15.990 11.990 7.990 4.000 298 1E21N050 10/16/00 AL 3.990 7.990 11.980 15.980 20.000 15.990 11.990 7.990 4.000 299 1E21N050 4/11/99 AF 3.977 7.966 11.975 15.989 20.004 16.003 11.993 7.987 4.000 300 1E21N050 4/11/99 AL 3.977 7.966 11.975 15.989 20.004 16.003 11.993 7.987 4.000 301 1E21N050 8/30/97 AF 3.990 8.000 12.000 15.980 19.990 16.000 12.000 8.000 4.000 302 1E21N050 8/30/97 AL 3.990 8.000 12.000 15.980 19.990 16.000 12.000 8.000 4.000 303 1E21N052 218/10 AF 4.040 8.000 12.010 16.000 20.000 16.010 12.010 8.000 4.040 304 1E21N052 2/8/10 AL 4.040 8.000 12.010 16.000 20.000 16.010 12.010 8.000 4.040 305 1E21N052 5/22/08 AF 3.990 7.920 11.920 15.900 19.900 15.900 11.910 7.910 3.990 306 1E21N052 5/22/08 AL 4.060 8.000 11.990 15.990 19.990 15.990 11.990 8.000 4.060 307 1E21N052 11/10106 AF 4.050 8.000 11.980 15.980 19.980 15.980 11.980 7.990 4.050 308 1E21N052 11/10106 AL 4.050 8.000 11.980 15.980 19.980 15.980 11.980 7.990 4.050 309 1E21N052 4/12/05 AF 3.940 7.930 11.930 15.940 19.940 15.930 11.930 7.930 3.960

DRIFT ANALYSIS ENGINEERING DEPARTMENT GRAND GULF NUCLEAR STATION Rosemount Range Codes 5 - 8 Gage Pressure Transmitters Input Data JC-Q1111-09019 Rev. 0 Page 47 of 134 AF/AL Data Seq.

AF/

Pt1 Pt2 Pt 3 Pt4 Pt5 Pt6 Pt7 PtS Pt9 Comments 10 Tag 10 Date AL (0% Up)

(25% Up) (50% Up) (75% Up)

(100%

(75% On) (50% On) (25% On)

(0% On) 310 1E21N052 4/12/05 AL 4.040 7.990 12.000 16.000 19.990 16.000 11.990 8.000 4.040 311 1E21N052 6/25/03 AF 4.090 8.120 12.120 16.230 20.310 16.230 12.120 8.120 4.100 312 1E21N052 6/25/03 AL 4.010 7.980 11.980 15.990 19.990 15.990 11.980 7.980 4.010 313 1E21N052 1/9/02 AF 4.070 7.990 11.910 15.850 19.760 15.830 11.900 7.980 4.090 314 1E21N052 1/9/02 AL 4.070 8.010 12.000 16.010 20.010 16.010 12.010 8.020 4.070 315 1E21N052 9/10/00 AF 4.000 7.940 11.930 15.930 19.930 15.940 11.940 7.940 4.000 316 1E21N052 9/10/00 AL 4.050 7.980 11.980 15.980 19.980 15.980 11.990 7.980 4.050 317 1E21N052 3/10/99 AF 4.050 7.990 11.980 15.980 19.990 15.990 11.990 7.980 4.060 318 1E21N052 3/10/99 AL 4.050 7.990 11.980 15.980 19.990 15.990 11.990 7.980 4.060 319 1E21N052 8/25/97 AF 4.041 8.023 12.017 16.014 20.007 16.009 12.020 8.019 4.052 320 1E21N052 8/25/97 AL 4.041 8.023 12.017 16.014 20.007 16.009 12.020 8.019 4.052 321 1E21N053 8/10/09 AF 4.030 7.990 11.990 15.990 19.990 16.000 12.000 7.990 4.040 322 1E21N053 8/10/09 AL 4.030 7.990 11.990 15.990 19.990 16.000 12.000 7.990 4.040 323 1E21N053 2/14/08 AF 4.050 7.990 12.000 16.000 20.000 16.000 12.010 8.000 4.050 324 1E21N053 2/14/08 AL 4.050 7.990 12.000 16.000 20.000 16.000 12.010 8.000 4.050 325 1E21N053 8/15/06 AF 4.030 8.000 12.000 16.020 19.990 16.020 12.000 8.000 4.030 326 1E21N053 8/15/06 AL 4.030 8.000 12.000 16.020 19.990 16.020 12.000 8.000 4.030 327 1E21N053 1/22/05 AF 4.020 7.980 12.000 15.990 20.020 15.990 12.000 7.990 4.020 328 1E21N053 1/22/05 AL 4.020 7.980 12.000 15.990 20.020 15.990 12.000 7.990 4.020 329 1E21N053 7/22/03 AF 4.020 8.040 12.100 16.160 20.210 16.170 12.100 8.040 4.030 330 1E21N053 7/22/03 AL 4.040 8.000 12.000 16.010 20.000 16.010 12.010 8.000 4.040 331 1E21N053 1/10/02 AF 4.020 8.030 12.040 16.020 20.010 16.030 12.040 8.040 4.030

DRIFT ANALYSIS ENGINEERING DEPARTMENT GRAND GULF NUCLEAR STATION Rosemount Range Codes 5 - 8 Gage Pressure Transmitters Input Data JC-Q1111-09019 Rev. 0 Page 48 of 134 AF/AL Data Seq.

AF/

Pt 1 Pt 2 Pt 3 Pt4 Pt5 Pt6 Pt7 Pt8 Pt9 Comments 10 TaalD Date AL (0% Up)

(25% Up) (50% Up) (75% Up)

(100%

(75% On) (50% On) (25% On)

(0% On) 332 1E21N053 1/10102 AL 4.020 8.030 12.040 16.020 20.010 16.030 12.040 8.040 4.030 333 1E21N053 9/10100 AF 3.980 7.900 11.900 15.880 19.870 15.900 11.890 7.900 3.980 334 1E21N053 9/10/00 AL 4.070 8.010 12.000 16.000 19.970 16.000 12.000 8.010 4.070 335 1E21N053 3/11/99 AF 4.047 8.000 12.000 16.010 20.010 16.020 12.010 8.000 4.039 336 1E21N053 3/11/99 AL 4.047 8.000 12.000 16.010 20.010 16.020 12.010 8.000 4.039 337 1E21N053 8/25/97 AF 4.034 8.018 12.014 16.002 20.008 15.994 12.010 7.999 4.038 338 1E21N053 8/25/97 AL 4.034 8.018 12.014 16.002 20.008 15.994 12.010 7.999 4.038 339 1E21N054 9/24/10 AF 4.010 7.980 11.980 15.980 19.990 15.990 12.000 8.000 4.020 340 1E21N054 9/24/10 AL 4.010 7.980 11.980 15.980 19.990 15.990 12.000 8.000 4.020 341 1E21N054 11/20108 AF 4.180 8.070 12.040 16.040 19.970 16.040 12.070 8.090 4.180 342 1E21N054 11/20108 AL 4.030 7.970 11.970 15.990 20.030 16.030 12.000 7.980 4.030 343 1E21N054 5/7/07 AF 4.020 7.990 11.980 15.980 19.970 16.000 12.010 8.010 4.020 344 1E21N054 5/7107 AL 4.020 7.990 11.980 15.980 19.970 16.000 12.010 8.010 4.020 345 1E21N054 811105 AF 4.020 7.990 11.980 15.980 19.980 16.000 12.010 8.010 4.030 346 1E21N054 811105 AL 4.020 7.990 11.980 15.980 19.980 16.000 12.010 8.010 4.030 347 1E21N054 1219/03 AF 4.020 7.970 11.990 16.010 19.990 15.990 12.000 7.990 4.030 348 1E21N054 12/9/03 AL 4.020 7.970 11.990 16.010 19.990 15.990 12.000 7.990 4.030 349 1E21N054 7/11/02 AF 4.030 8.000 12.000 16.000 20.010 16.000 11.990 7.990 4.030 350 1E21N054 7/11/02 AL 4.030 8.000 12.000 16.000 20.010 16.000 11.990 7.990 4.030 351 1E21N054 1/23/01 AF 4.020 7.990 11.990 15.990 19.990 15.990 12.000 8.000 4.020 352 1E21N054 1/23/01 AL 4.020 7.990 11.990 15.990 19.990 15.990 12.000 8.000 4.020 353 1E21N054 7/12/99 AF 4.034 8.000 11.997 15.982 19.983 16.000 12.014 8.011 4.035

DRIFT ANALYSIS ENGINEERING DEPARTMENT GRAND GULF NUCLEAR STATION Rosemount Range Codes 5 - 8 Gage Pressure Transmitters Input Data JC-Q1111-09019 Rev. 0 Page 49 of 134 AF/AL Data Seq.

AF/

pt1 Pt 2 Pt 3 Pt4 Pt5 pt6 Pt7 pta Pt9 Comments 10 Tag 10 Date AL (0% Up)

(25% Up)

(50% Up)

(75% Up)

(100%

(75% On) (50% On) (25% On)

(0% On) 354 1E21N054 7/12/99 AL 4.034 8.000 11.997 15.982 19.983 16.000 12.014 8.011 4.035 355 1E21N054 1/15/98 AF 4.020 8.000 11.980 16.000 20.010 16.020 12.010 8.010 4.020 356 1E21N054 1/15/98 AL 4.020 8.000 11.980 16.000 20.010 16.020 12.010 8.010 4.020 357 1E22N050 3/19/10 AF 5.850 8.080 11.910 16.070 19.910 16.070 11.910 8.070 5.840 358 1E22N050 3/19/10 AL 5.880 8.120 11.960 16.120 19.960 16.120 11.960 8.120 5.880 Deleted Data Points 1 & 9. Too great a difference from Data Points 1 & 9 for all other 359 1E22N050 6/27108 AF EXC 8.100 11.940 16.110 19.950 16.110 11.950 8.100 EXC transmitters in data set. Insufficient calibration data for these Data Points to support drift analysis.

360 1E22N050 6/27108 AL EXC 8.100 11.940 16.110 19.950 16.110 11.950 8.100 EXC Deleted Data Points 1 & 9. Too great a difference from Data Points 1 & 9 for all other 361 1E22N050 11/15/06 AF EXC 8.110 11.930 16.080 19.900 16.080 11.930 8.110 EXC transmitters in data set. Insufficient calibration data for these Data Points to support drift analysis.

362 1E22N050 11/15/06 AL EXC 8.120 11.960 16.120 19.960 16.120 11.960 8.120 EXC Deleted Data Points 1 & 9. Too great a difference from Data Points 1 & 9 for all other 363 1E22N050 6/3/05 AF EXC 7.860 11.860 15.960 19.860 15.990 11.720 7.920 EXC transmitters in data set. Insufficient calibration data for these Data Points to support drift analysis.

364 1E22N050 6/3/05 AL EXC 8.120 11.940 16.100 19.950 16.110 11.950 8.140 EXC Deleted Data Points 1 & 9. Too great a difference from Data Points 1 & 9 for all other 365 1E22N050 9/26/03 AF EXC 7.960 11.830 16.000 19.830 16.000 11.840 7.980 EXC transmitters in data set. Insufficient calibration data for these Data Points to support drift analysis.

366 1E22N050 9/26/03 AL EXC 8.110 11.930 16.120 19.970 16.140 11.960 8.100 EXC Deleted Data Points 1 & 9. Too great a difference from Data Points 1 & 9 for all other 367 1E22N050 4/12102 AF EXC 8.090 11.930 16.080 19.930 16.090 11.940 8.100 EXC transmitters in data set. Insufficient calibration data for these Data Points to support drift analysis.

DRIFT ANALYSIS ENGINEERING DEPARTMENT GRAND GULF NUCLEAR STATION Rosemount Range Codes 5 - 8 Gage Pressure Transmitters Input Data JC-Q1111-09019 Rev. 0 Page 50 of 134 AF/AL Data Seq.

AFI Pt1 Pt2 Pt3 Pt4 Pt5 Pt6 Pt7 PtS Pt9 Comments 10 Tag 10 Date AL (0% Up)

(25% Up)

(50% Up)

(75% Up)

(100%

(75% On) 1(50% On) (25% On)

(0% On) 368 1E22N050 4/12/02 AL EXC 8.090 11.930 16.080 19.930 16.090 11.940 8.100 EXC Deleted Data Points 1 & 9. Too great a difference from Data Points 1 & 9 for all other 369 1E22N050 11/24/00 AF EXC 8.210 12.010 16.150 19.970 16.130 11.960 8.140 EXC transmitters in data set. Insufficient calibration data for these Data Points to support drift analysis.

370 1E22N050 11/24/00 AL EXC 8.160 11.980 16.120 19.950 16.120 11.930 8.150 EXC Deleted Data Points 1 & 9. Too great a difference from Data Points 1 & 9 for all other 371 1E22N050 4/2/99 AF EXC 8.110 11.950 16.110 19.930 16.110 11.950 8.110 EXC transmitters in data set. Insufficient calibration data for these Data Points to support drift analysis.

372 1E22N050 4/2/99 AL EXC 8.110 11.950 16.110 19.930 16.110 11.950 8.110 EXC Deleted Data Points 1 & 9. Too great a difference from Data Points 1 & 9 for all other 373 1E22N050 9/5/97 AF EXC 8.086 11.980 16.135 19.982 16.096 11.952 8.134 EXC transmitters in data set. Insufficient calibration data for these Data Points to support drift analysis.

374 1E22N050 9/5/97 AL EXC 8.086 11.980 16.135 19.982 16.096 11.952 8.134 EXC 375 1E22N054C 4/2110 AF 4.070 7.950 11.980 15.990 19.990 15.990 11.980 7.950 4.070 376 1E22N054C 4/2/10 AL 4.060 7.930 11.940 15.960 19.970 15.960 11.940 7.930 4.060 Transmitter electronic boards changed out per 377 1E22N054C 5/30/08 AF 4.090 7.950 11.970 15.990 20.010 15.990 11.970 7.950 4.090 WO 139126 (AF data using old circuit boards, AL data from new circuit boards).

378 1E22N054C 5/30/08 AL 4.060 7.930 11.950 15.970 19.970 15.970 11.960 7.930 4.060 379 1E22N054C 1/12107 AF EXC EXC EXC EXC EXC EXC EXC EXC EXC Exclude all AF data due to calibration data change.

380 1E22N054C 1/12/07 AL 4.070 7.920 11.950 15.970 19.980 15.970 11.950 7.930 4.070 381 1E22N054G 11/20/09 AF 4.060 7.920 11.940 15.970 19.990 15.980 11.960 7.930 4.070 382 1E22N054G 11/20/09 AL 4.060 7.920 11.940 15.970 19.990 15.980 11.960 7.930 4.070 383 1E22N054G 5/30/08 AF 4.060 7.900 11.920 15.940 19.960 15.940 11.920 7.910 4.060 384 1E22N054G 5/30/08 AL 4.050 7.910 11.940 15.960 19.970 15.950 11.940 7.910 4.050

DRIFT ANALYSIS ENGINEERING DEPARTMENT GRAND GULF NUCLEAR STATION Rosemount Range Codes 5 - 8 Gage Pressure Transmitters Input Data JC-Q1111-09019 Rev. 0 Page 51 of 134 AF/AL Data Seq.

AFt Pt 1 Pt2 Pt3 Pt4 Pt 5 Pt6 Pt7 Pt8 Pt9 Comments 10 Tag 10 Date AL (0% Up)

(25% Up)

(50% Up)

(75% Up)

(100%

(75% On) (50% On) 1(25% On)

(0% On) 385 1E22N054G 10/20/06 AF EXC EXC EXC EXC EXC EXC EXC EXC EXC Exclude all AF data due to calibration data change.

386 1E22N054G 10/20/06 AL 4.060 7.900 11.920 15.940 19.970 15.940 11.920 7.900 4.060 387 1E31N085A 5/12/10 AF 4.020 7.990 11.980 15.980 20.000 15.990 11.980 7.990 4.020 388 1E31N085A 5/12/10 AL 4.020 7.990 11.980 15.980 20.000 15.990 11.980 7.990 4.020 389 1E31N085A 9/30/08 AF 3.970 7.960 11.940 15.950 19.970 15.950 11.940 7.960 3.970 390 1E31N085A 9/30/08 AL 4.000 7.980 11.980 15.980 20.000 15.980 11.980 7.990 4.000 391 1E31N085A 4/2/07 AF 3.990 7.990 11.970 15.970 20.000 15.980 11.980 7.990 4.010 392 1E31N085A 4/2/07 AL 3.990 7.990 11.970 15.970 20.000 15.980 11.980 7.990 4.010 393 1E31N085A 9/28/05 AF 4.000 7.960 11.940 15.930 19.940 15.930 11.940 7.970 4.010 394 1E31N085A 9/28/05 AL 4.010 7.980 11.980 15.970 20.000 15.980 11.980 7.980 4.010 395 1E31N085A 3/5/04 AF 3.960 7.980 11.980 15.980 20.020 15.980 11.980 7.980 3.970 Worked in conjunction with WO 50336454 (replaced transmitter electroncs boards).

396 1E31N085A 3/5/04 AL 3.990 7.980 11.980 15.970 20.020 15.970 11.970 7.970 3.990 397 1E31N085A 9/23/02 AF 3.980 7.990 11.980 16.000 20.040 16.000 11.990 7.990 4.030 398 1E31N085A 9/23/02 AL 3.980 7.990 11.980 16.000 20.040 16.000 11.990 7.990 4.030 399 1E31N085A 4/24/01 AF 4.130 8.140 12.140 16.160 20.160 16.170 12.150 8.150 4.130 400 1E31N085A 4/24/01 AL 4.000 8.010 12.010 16.020 20.020 16.020 12.020 8.010 4.010 401 1E31N085A 11/4/99 AF 3.790 7.750 11.720 15.710 19.720 15.720 11.710 7.750 3.780 402 1E31N085A 11/4/99 AL 4.010 7.980 11.980 15.980 20.010 15.980 11.980 7.990 4.010 403 1E31N085A 4/24/98 AF 4.010 8.000 11.970 15.982 20.000 15.981 11.973 7.988 3.971 404 1E31N085A 4/24/98 AL 4.010 8.000 11.970 15.982 20.000 15.981 11.973 7.988 3.971 405 1E31N085B 5/4/10 AF 3.950 7.900 11.880 15.880 19.930 15.890 11.880 7.910 3.950 406 1E31N085B 5/4/10 AL 4.020 7.980 11.970 15.980 20.030 15.980 11.970 7.980 4.020

DRIFT ANALYSIS ENGINEERING DEPARTMENT GRAND GULF NUCLEAR STATION Rosemount Range Codes 5 - 8 Gage Pressure Transmitters Input Data JC-Q1111-09019 Rev. 0 Page 52 of 134 AF/AL Data Seq.

AF/

pt1 Pt2 Pt3 pt4 Pt5 Pt6 Pt 7 PtB Pt9 Comments 10 Tag 10 Date AL (0% Up)

(25% Up)

(50% Up)

(75% Up)

(100%

1(75% On) (50% On) (25% On)

(0% On) 407 1E31N085B 9/30/08 AF 4.000 7.970 11.970 15.980 20.010 15.980 11.980 8.000 4.010 408 1E31N085B 9/30/08 AL 4.000 7.970 11.970 15.980 20.010 15.980 11.980 8.000 4.010 409 1E31N085B 4/1/07 AF 4.070 8.070 12.080 16.080 20.110 16.050 12.050 8.060 4.070 410 1E31N085B 4/1/07 AL 4.020 7.990 11.980 15.980 20.020 15.980 11.980 7.990 4.020 411 1E31N085B 9/27/05 AF 4.020 7.970 11.930 15.910 19.940 15.920 11.930 7.970 4.030 412 1E31N085B 9/27105 AL 4.030 7.980 11.980 15.980 20.020 15.980 11.980 7.980 4.030 AF Data grossly out of tolerance. Transmitter 413 1E31N085B 3/4/04 AF 5.500 9.800 13.750 17.670 21.570 17.750 13.750 9.750 6.000 electronic boards replaced as per scheduled PM and transmitter was recalibrated successfully.

414 1E31N085B 3/4/04 AL 4.030 8.030 11.970 15.970 20.020 15.970 11.970 8.000 4.020 415 1E31N085B 9/23/02 AF 3.980 8.010 12.050 16.100 20.200 16.180 12.080 8.020 3.990 416 1E31N085B 9/23/02 AL 4.010 7.980 11.970 15.980 20.010 15.980 11.980 7.990 4.010 417 1E31N085B 4/19/01 AF 4.120 8.060 11.990 15.940 19.910 15.940 11.990 8.060 4.120 418 1E31N085B 4/19/01 AL 4.010 7.990 11.980 15.990 20.000 15.990 11.980 7.990 4.010 419 1E31N085B 11/17/99 AF 3.930 7.880 11.830 15.830 19.830 15.830 11.840 7.880 3.930 420 1E31N085B 11/17/99 AL 4.020 8.000 11.990 16.000 20.020 16.000 11.990 8.000 4.020 421 1E31N085B 4/24/98 AF 4.039 7.987 12.001 15.991 20.002 15.980 11.985 8.001 4.007 422 1E31N085B 4/24/98 AL 4.039 7.987 12.001 15.991 20.002 15.980 11.985 8.001 4.007 423 1E32N050 5/4/10 AF 4.000 8.000 11.990 15.980 20.000 15.990 12.000 8.000 4.000 424 1E32N050 5/4/10 AL 4.000 8.000 11.990 15.980 20.000 15.990 12.000 8.000 4.000 425 1E32N050 10/4/08 AF 4.030 8.040 12.030 16.030 20.040 16.030 12.040 8.040 4.030 426 1E32N050 10/4/08 AL 4.000 8.000 12.000 15.990 20.000 15.990 12.000 8.000 4.000 427 1E32N050 4/4/07 AF 4.040 8.020 12.010 16.010 20.010 16.010 12.010 8.020 4.040

DRIFT ANALYSIS ENGINEERING DEPARTMENT GRAND GULF NUCLEAR STATION Rosemount Range Codes 5 - 8 Gage Pressure Transmitters Input Data JC-Q1111-09019 Rev. 0 Page 53 of 134 AF/AL Data Seq.

AFt Pt1 Pt2 pt3 Pt4 Pt 5 Pt6 Pt7 Pt8 pt9 Comments 10 Tag 10 Date AL (0% Up)

(25% Up)

(50% Up)

(75% Up)

(100%

!(75% On) (50% On) (25% On)

(0% On) 428 1E32N050 4/4/07 AL 4.040 8.020 12.010 16.010 20.010 16.010 12.010 8.020 4.040 429 1E32N050 9/29/05 AF 3.980 8.010 11.990 16.000 19.990 15.980 11.980 7.980 4.000 430 1E32N050 9/29/05 AL 3.980 8.010 11.990 16.000 19.990 15.980 11.980 7.980 4.000 431 1E32N050 3/7/04 AF EXC EXC EXC EXC EXC EXC EXC EXC EXC All AF data excluded due to calibration data change.

432 1E32N050 3/7/04 AL 4.040 8.030 12.020 16.010 20.020 16.010 12.030 8.040 4.040 433 1E32N050 9/28/02 AF 4.000 8.030 12.010 16.010 20.010 16.010 12.020 8.030 4.010 434 1E32N050 9/28/02 AL 4.000 8.030 12.010 16.010 20.010 16.010 12.020 8.030 4.010 435 1E32N050 5/3/01 AF 3.630 7.640 11.630 15.630 19.640 15.640 11.660 7.650 3.610 436 1E32N050 5/3/01 AL 4.000 8.010 12.000 16.000 20.000 16.000 12.010 7.990 3.990 437 1E32N050 11/6/99 AF 4.230 8.130 11.990 15.870 19.750 15.860 12.000 8.120 4.240 438 1E32N050 11/6/99 AL 4.010 8.000 11.990 15.990 19.980 15.990 11.990 8.000 4.010 439 1E32N050 5/31/99 AF 3.981 8.139 12.240 16.400 20.547 16.400 12.240 8.139 3.981 440 1E32N050 5/31/99 AL 4.010 7.980 11.960 15.980 20.000 15.980 11.970 7.990 4.010 441 1E32N050 10/6/97 AF 3.970 7.970 11.990 15.970 19.980 15.970 12.010 7.980 4.000 442 1E32N050 10/6/97 AL 3.970 7.970 11.990 15.970 19.980 15.970 12.010 7.980 4.000 443 1E32N055 7/8/09 AF 4.000 7.990 11.990 16.000 20.020 16.000 12.010 8.000 4.000 444 1E32N055 7/8/09 AL 4.000 7.990 11.990 16.000 20.020 16.000 12.010 8.000 4.000 445 1E32N055 1/7108 AF 3.990 8.000 12.000 16.010 20.040 16.010 12.010 8.010 4.000 446 1E32N055 1/7/08 AL 3.990 8.000 12.000 16.010 20.040 16.010 12.010 8.010 4.000 447 1E32N055 4/5/06 AF 4.000 7.980 11.980 15.970 20.000 15.980 11.980 7.990 4.000 448 1E32N055 4/5/06 AL 4.000 7.980 11.980 15.970 20.000 15.980 11.980 7.990 4.000 449 1E32N055 10/6/04 AF 4.010 7.970 11.930 15.940 19.990 15.940 11.950 7.970 4.020

DRIFT ANALYSIS ENGINEERING DEPARTMENT GRAND GULF NUCLEAR STATION Rosemount Range Codes 5 - 8 Gage Pressure Transmitters Input Data JC-Q1111-09019 Rev. 0 Page 54 of 134 AF/AL Data Seq.

AFt Pt1 Pt 2 Pt3 Pt4 Pt5 Pt6 Pt7 PtB Pt9 Comments 10 Tag 10 Date AL (0% Up)

(25% Up) (50% Up) (75% Up)

(100%

(75% On) (50% On) *(25% On)

(0% On) 450 1E32N055 10/6/04 AL 4.000 7.980 11.960 15.970 20.000 15.980 11.980 7.980 3.990 451 1E32N055 4/22/03 AF 4.040 8.020 12.000 16.000 20.030 16.000 12.010 8.020 4.040 452 1E32N055 4/22/03 AL 4.030 8.000 11.970 15.970 20.020 15.980 11.970 8.000 4.030 453 1E32N055 11/19/01 AF 4.050 7.990 11.980 15.940 19.950 15.930 11.960 7.970 4.040 454 1E32N055 11/19/01 AL 4.000 7.990 11.990 15.970 19.990 15.960 12.000 8.000 4.000 455 1E32N055 8/17/00 AF 4.010 7.960 11.930 15.930 19.960 15.940 11.960 7.980 3.990 456 1E32N055 8/17/00 AL 4.000 8.000 11.970 15.970 20.010 15.970 11.980 7.990 4.010 457 1E32N055 2/16/99 AF 4.010 7.990 11.990 15.990 19.990 15.970 12.000 8.010 3.980 458 1E32N055 2/16/99 AL 4.010 7.990 11.990 15.990 19.990 15.970 12.000 8.010 3.980 459 1E32N055 8/19/97 AF 3.990 8.000 11.980 15.980 19.990 15.980 11.980 8.020 4.000 460 1E32N055 8/19/97 AL 3.990 8.000 11.980 15.980 19.990 15.980 11.980 8.020 4.000 461 1E32N058 4/30/10 AF 3.990 8.010 12.000 15.990 19.990 15.990 12.010 8.010 3.990 462 1E32N058 4/30/10 AL 3.990 8.010 12.000 15.990 19.990 15.990 12.010 8.010 3.990 463 1E32N058 10/2/08 AF 4.000 8.020 12.020 16.020 20.030 16.020 12.030 8.020 4.000 464 1E32N058 10/2/08 AL 4.000 8.020 12.020 16.020 20.030 16.020 12.030 8.020 4.000 465 1E32N058 3/25/07 AF 3.990 8.020 12.020 16.020 20.030 16.020 12.020 8.020 3.990 466 1E32N058 3/25/07 AL 3.990 8.020 12.020 16.020 20.030 16.020 12.020 8.020 3.990 467 1E32N058 9/22105 AF 4.000 8.010 12.000 15.990 19.990 15.990 12.010 8.010 4.000 468 1E32N058 9/22/05 AL 4.000 8.010 12.000 15.990 19.990 15.990 12.010 8.010 4.000 469 1E32N058 3/5/04 AF EXC EXC EXC EXC EXC EXC EXC EXC EXC All AF data excluded due to calibration data change.

470 1E32N058 3/5/04 AL 4.000 8.010 12.000 15.990 19.980 15.990 12.010 8.020 4.000 471 1E32N058 9/15/02 AF 3.900 7.940 11.950 15.920 19.930 15.920 11.930 7.940 3.900

DRIFT ANALYSIS ENGINEERING DEPARTMENT GRAND GULF NUCLEAR STATION Rosemount Range Codes 5 - 8 Gage Pressure Transmitters Input Data JC-Q1111-09019 Rev. 0 Page 55 of 134 AF/AL Data Seq.

AFI Pt 1 Pt2 Pt 3 Pt4 Pt5 Pt6 Pt7 PtS Pt9 Comments 10 Tag 10 Date AL (0% Up)

(25% Up)

(50% Up)

(75% Up)

(100%

(75% On) (50% On) (25% On)

(0% On) 472 1E32N058 9/15/02 AL 3.990 8.020 12.010 15.990 19.990 15.990 12.010 8.020 3.970 473 1E32N058 4/23/01 AF 2.750 6.180 9.970 13.740 17.600 13.740 9.990 6.180 2.750 474 1E32N058 4/23/01 AL 4.000 8.020 12.020 16.020 20.020 16.020 12.020 8.020 4.000 475 1E32N058 11/9/99 AF EXC EXC EXC EXC EXC EXC EXC EXC EXC AF and AL data excluded due to bad M&TE calibration.

476 1E32N058 11/9/99 AL EXC EXC EXC EXC EXC EXC EXC EXC EXC 477 1E32N058 6/21/99 AF 4.150 8.320 12.430 16.550 20.700 16.550 12.430 8.320 4.140 478 1E32N058 6/21/99 AL 4.000 8.000 11.980 15.980 20.000 15.980 11.990 8.000 3.990 479 1E32N058 10/28/97 AF 3.970 7.980 12.000 16.010 20.040 16.030 12.020 8.000 3.960 480 1E32N058 10/28/97 AL 4.010 8.020 11.990 15.980 19.990 15.980 12.010 8.000 3.990 481 1E32N061A 8/12/09 AF 4.010 8.010 12.000 15.990 20.000 16.000 12.000 8.010 4.010 482 1E32N061A 8/12109 AL 4.010 8.010 12.000 15.990 20.000 16.000 12.000 8.010 4.010 483 1E32N061A 2/15/08 AF 4.000 8.000 12.000 15.990 20.000 15.990 12.000 8.000 4.000 484 1E32N061A 2/15/08 AL 4.000 8.000 12.000 15.990 20.000 15.990 12.000 8.000 4.000 485 1E32N061A 8/28/06 AF 4.010 8.010 12.000 15.990 20.000 16.000 12.000 8.010 4.010 486 1E32N061A 8/28/06 AL 4.010 8.010 12.000 15.990 20.000 16.000 12.000 8.010 4.010 487 1E32N061A 1/7/05 AF EXC EXC EXC EXC EXC EXC EXC EXC EXC All AF data excluded due to calibration data change.

488 1E32N061A 117105 AL 4.000 8.000 12.000 15.990 20.000 16.000 12.000 8.000 4.000 489 1E32N061A 5/13/03 AF 3.950 7.970 11.950 15.950 19.950 15.950 11.950 7.970 3.950 490 1E32N061A 5/13/03 AL 4.000 8.020 12.000 16.000 20.000 16.000 12.000 8.020 4.000 491 1E32N061A 11/26/01 AF 4.010 8.020 12.070 16.080 20.100 16.070 12.080 8.030 4.020 492 1E32N061A 11/26/01 AL 4.000 8.020 12.020 16.010 20.000 16.000 12.020 8.030 4.000 493 1E32N061A 10/2/00 AF 4.000 7.970 11.950 15.900 19.900 15.910 11.950 7.990 4.000

DRIFT ANALYSIS ENGINEERING DEPARTMENT GRAND GULF NUCLEAR STATION Rosemount Range Codes 5 - 8 Gage Pressure Transmitters Input Data JC-Q1111-09019 Rev. 0 Page 56 of 134 AF/AL Data Seq.

AFI Pt 1 Pt2 Pt 3 Pt4 Pt5 Pt6 Pt7 Pt8 Pt9 Comments 10 Tag 10 Oate AL (0% Up) *(25% Up) (50% Up)

(75% Up)

(100%

1(75% On) (50% On) 1(25% On)

(0% On) 494 1E32N061A 10/2/00 AL 4.020 8.010 12.010 16.000 20.020 16.010 12.020 8.030 4.030 495 1E32N061A 4/9/99 AF 4.040 8.000 12.000 16.000 20.010 16.010 12.020 8.020 4.030 496 1E32N061A 4/9/99 AL 4.040 8.000 12.000 16.000 20.010 16.010 12.020 8.020 4.030 497 1E32N061A 10/8/97 AF 4.100 8.100 12.090 16.110 20.100 16.110 12.090 8.110 4.100 498 1E32N061A 10/8/97 AL 3.990 8.000 12.000 16.000 20.000 16.000 12.000 8.000 4.000 499 1E32N061E 11/2/09 AF 3.980 7.980 11.990 15.990 19.990 15.990 11.990 7.990 3.980 500 1E32N061E 11/2/09 AL 3.980 7.980 11.990 15.990 19.990 15.990 11.990 7.990 3.980 501 1E32N061E 1/30/08 AF 3.990 7.990 11.990 15.990 19.990 15.990 11.990 7.990 3.990 502 1E32N061E 1/30/08 AL 3.990 7.990 11.990 15.990 19.990 15.990 11.990 7.990 3.990 503 1E32N061E 4/14/06 AF 4.040 8.040 12.040 16.030 20.040 16.030 12.040 8.040 4.040 504 1E32N061E 4/14/06 AL 4.000 8.000 12.000 15.990 20.000 15.990 11.990 8.000 4.000 505 1E32N061E 10/28/04 AF EXC EXC EXC EXC EXC EXC EXC EXC EXC All AF data excluded due to calibration data change.

506 1E32N061E 10/28/04 AL 4.030 8.020 12.020 16.010 20.000 16.010 12.020 8.020 4.030 507 1E32N061E 5/28/03 AF 3.930 7.930 11.920 15.910 19.910 15.910 11.920 7.930 3.930 508 1E32N061E 5/28/03 AL 3.990 7.990 11.990 15.990 19.990 15.990 11.990 7.990 3.990 509 1E32N061E 11/28/01 AF 3.960 7.970 11.960 15.930 19.900 15.920 11.960 7.970 3.960 510 1E32N061E 11/28/01 AL 4.000 8.010 12.010 16.000 19.990 15.990 12.000 8.010 4.000 511 1E32N061E 11/30/00 AF 4.020 8.040 12.060 16.070 20.060 16.060 12.070 8.040 4.030 512 1E32N061E 11/30/00 AL 4.010 8.020 12.030 16.010 19.980 16.000 12.030 8.020 4.010 513 1E32N061E 4/9/99 AF 3.970 7.960 11.940 15.940 19.950 15.950 11.940 7.950 3.950 514 1E32N061E 4/9/99 AL 4.000 7.990 11.990 15.990 20.000 16.000 11.990 8.000 3.990 515 1E32N061E 10/8/97 AF 4.020 7.990 12.000 16.010 19.990 15.990 12.000 8.010 3.990

DRIFT ANALYSIS ENGINEERING DEPARTMENT GRAND GULF NUCLEAR STATION Rosemount Range Codes 5 - 8 Gage Pressure Transmitters Input Data JC-Q1111-09019 Rev. 0 Page 57 of 134 AF/AL Data Seq.

AF/

Pt 1 pt2 Pt 3 Pt4 Pt 5 pt6 Pt7 pta Pt9 Comments 10 Tag 10 Date AL (0% Up)

(25% Up)

(50% Up)

(75% Up)

(100%

(75% On) 1(50% On) (25% On)

(0% On) 516 1E32N061E 10/8/97 AL 4.020 7.990 12.000 16.010 19.990 15.990 12.000 8.010 3.990 517 1E32N061J 5/5/09 AF 3.990 7.970 11.960 15.970 20.000 15.960 11.970 7.970 4.000 518 1E32N061J 5/5/09 AL 3.990 7.970 11.960 15.970 20.000 15.960 11.970 7.970 4.000 519 1E32N061J 11/9/07 AF 4.030 8.010 12.000 16.000 20.030 15.990 11.990 8.000 4.020 520 1E32N061J 11/9/07 AL 4.030 8.010 12.000 16.000 20.030 15.990 11.990 8.000 4.020 521 1E32N061J 5/11/06 AF 4.030 7.980 11.950 15.940 19.950 15.940 11.950 7.990 4.030 522 1E32N061J 5/11/06 AL 4.020 7.990 11.970 15.980 20.020 15.980 11.980 7.990 4.020 523 1E32N061J 9/29/04 AF EXC EXC EXC EXC EXC EXC EXC EXC EXC All AF data excluded due to calibration data change.

524 1E32N061J 9/29/04 AL 4.040 8.000 11.960 15.960 19.980 15.970 11.980 8.000 4.040 525 1E32N061J 4/3/03 AF 3.980 7.980 11.980 15.980 20.010 15.990 11.980 7.980 3.980 Transmitter electonics changed out per MAl 303978.

526 1E32N061J 4/3/03 AL 4.000 7.980 11.960 15.960 20.000 15.970 11.970 7.980 4.000 527 1E32N061J 11/12/01 AF 3.960 7.930 11.930 15.960 20.020 15.960 11.940 7.940 3.940 528 1E32N061J 11/12/01 AL 4.000 7.980 11.980 15.980 20.000 15.980 11.980 7.980 4.000 529 1E32N061J 7/24/00 AF 4.130 8.090 12.090 16.100 20.120 16.090 12.090 8.110 4.150 530 1E32N061J 7/24/00 AL 3.980 7.960 11.970 15.980 20.000 15.980 11.960 7.970 3.990 531 1E32N061J 1/27/99 AF 4.030 8.010 12.000 16.010 20.030 16.010 12.000 8.010 4.030 532 1E32N061J 1/27/99 AL 4.030 8.010 12.000 16.010 20.030 16.010 12.000 8.010 4.030 533 1E32N061J 7/16/97 AF 3.890 7.870 11.850 15.810 19.820 15.780 11.800 7.860 3.900 534 1E32N061J 7/16/97 AL 4.020 8.010 11.990 15.990 20.000 15.980 11.970 7.990 4.020 535 1E32N061N 12/8/09 AF 4.010 8.000 12.000 16.000 20.000 16.000 12.000 8.010 4.010 536 1E32N061N 1218/09 AL 4.010 8.000 12.000 16.000 20.000 16.000 12.000 8.010 4.010 537 1E32N061N 6/16/08 AF 4.010 8.010 12.000 15.990 20.010 16.000 12.000 8.010 4.010

DRIFT ANALYSIS ENGINEERING DEPARTMENT GRAND GULF NUCLEAR STATION Rosemount Range Codes 5 - 8 Gage Pressure Transmitters Input Data JC-Q1111-09019 Rev. 0 Page 58 of 134 AF/AL Data Seq.

AFI pt1 Pt2 Pt 3 Pt4 Pt 5 Pt6 Pt7 PtS Pt 9 Comments 10 Tag 10 Oate AL (0% Up)

(25% Up)

(50% Up)

(75% Up)

(100%

(75% On) (50% On) 1(25% On)

(0% On) 538 1E32N061N 6/16/08 AL 4.010 8.010 12.000 15.990 20.010 16.000 12.000 8.010 4.010 539 1E32N061N 8/28/06 AF 4.010 8.010 12.000 16.000 20.010 16.000 12.010 8.010 4.010 540 1E32N061N 8/28/06 AL 4.010 8.010 12.000 16.000 20.010 16.000 12.010 8.010 4.010 541 1E32N061N 1/7/05 AF EXC EXC EXC EXC EXC EXC EXC EXC EXC All AF data excluded due to calibration data change.

542 1E32N061N 1/7/05 AL 4.010 8.010 12.000 16.000 20.010 16.000 12.010 8.000 4.010 543 1E32N061N 5/16/03 AF 3.920 7.920 11.920 15.930 19.960 15.940 11.930 7.930 3.920 544 1E32N061N 5/16/03 AL 4.010 8.010 12.020 16.010 20.020 16.020 12.020 8.010 4.010 545 1E32N061N 11/12/01 AF 3.960 7.960 11.970 15.970 19.990 15.970 11.970 7.970 3.960 546 1E32N061N 11/12/01 AL 4.000 8.000 12.000 15.990 20.000 15.990 12.000 8.000 4.000 547 1E32N061N 10/2/00 AF 4.080 8.040 11.980 15.940 19.940 15.950 11.990 8.030 4.070 548 1E32N061N 10/2/00 AL 3.990 8.000 11.990 15.980 19.990 15.980 11.990 7.990 4.010 549 1E32N061N 4/10/99 AF 4.014 7.982 11.993 15.987 19.983 15.990 11.989 7.992 4.012 550 1E32N061N 4/10/99 AL 4.014 7.982 11.993 15.987 19.983 15.990 11.989 7.992 4.012 551 1E32N061N 10/7/97 AF 4.030 8.030 12.020 15.970 19.970 15.980 12.010 8.000 3.990 552 1E32N061N 1017/97 AL 4.030 8.030 12.020 15.970 19.970 15.980 12.010 8.000 3.990 553 1E51N035A 4/24/10 AF 4.030 8.040 11.900 15.910 19.920 15.930 11.910 8.050 4.020 554 1E51N035A 4/24/10 AL 4.030 8.040 11.900 15.910 19.920 15.930 11.910 8.050 4.020 555 1E51N035A 7/2108 AF 4.010 8.040 11.890 15.910 19.930 15.920 11.890 8.040 4.020 556 1E51N035A 7/2/08 AL 4.030 8.050 11.910 15.920 19.930 15.920 11.900 8.050 4.030 557 1E51N035A 2/1/08 AF 4.020 8.040 11.900 15.920 19.920 15.920 11.910 8.040 4.020 558 1E51N035A 211/08 AL 4.020 8.040 11.900 15.920 19.920 15.920 11.910 8.040 4.020 559 1E51N035A 8/5/06 AF EXC EXC EXC EXC EXC EXC EXC EXC EXC Exclude all AF data due to calibration data change.

DRIFT ANALYSIS ENGINEERING DEPARTMENT GRAND GULF NUCLEAR STATION Rosemount Range Codes 5 - 8 Gage Pressure Transmitters Input Data JC-Q1111-09019 Rev. 0 Page 59 of 134 AF/AL Data Seq.

AF/

Pt 1 pt2 Pt 3 pt4 Pt 5 pt6 Pt7 Pta Pt 9 Comments 10 Tag 10 Date AL (0% Up)

(25% Up)

(50% Up)

(75% Up)

(100%

(75% On) (50% On) 1(25% On)

(0% On) 560 1E51N035A 8/5/06 AL 4.030 8.050 11.900 15.920 19.940 15.920 11.900 8.040 4.010 561 1E51N035E 4/25/10 AF 4.070 8.050 11.890 15.920 19.960 15.930 11.900 8.060 4.070 562 1E51N035E 4/25/10 AL 4.020 8.020 11.870 15.890 19.940 15.890 11.880 8.020 4.020 Transmitter electronic boards changed out per 563 1E51N035E 6/30/08 AF 4.030 8.050 11.910 15.940 19.950 15.930 11.920 8.050 4.020 WO 139131; AF data prior to change-out, AL data after change-out.

564 1E51N035E 6/30/08 AL 4.040 8.040 11.890 15.920 19.960 15.920 11.900 8.040 4.040 565 1E51N035E 10/8/06 AF EXC EXC EXC EXC EXC EXC EXC EXC EXC Exclude all AF data due to calibration data change.

566 1E51N035E 10/8/06 AL 4.020 8.040 11.900 15.920 19.940 15.920 11.900 8.050 4.030 567 1E51N055A 6/29/09 AF 4.010 8.000 12.000 15.990 20.000 16.000 12.000 8.000 4.010 568 1E51N055A 6/29/09 AL 4.010 8.000 12.000 15.990 20.000 16.000 12.000 8.000 4.010 569 1E51N055A 1/2/08 AF 4.000 8.000 12.000 16.000 20.020 16.000 12.000 8.000 4.000 570 1E51N055A 1/2/08 AL 4.000 8.000 12.000 16.000 20.020 16.000 12.000 8.000 4.000 571 1E51N055A 3/18/06 AF 4.000 8.000 12.010 16.020 20.030 16.020 12.020 8.010 4.000 572 1E51N055A 3/18/06 AL 4.000 8.000 12.010 16.020 20.030 16.020 12.020 8.010 4.000 573 1E51N055A 8/4/04 AF 4.010 8.000 12.000 16.000 20.010 16.000 12.000 8.000 4.000 574 1E51N055A 8/4/04 AL 4.010 8.000 12.000 16.000 20.010 16.000 12.000 8.000 4.000 575 1E51N055A 2/19/03 AF 3.980 7.970 11.960 15.950 19.950 15.950 11.960 7.970 3.980 576 1E51N055A 2/19/03 AL 4.000 8.000 12.000 16.000 20.000 16.000 12.000 8.000 4.000 577 1E51N055A 4/24/01 AF 3.980 7.980 11.970 15.970 19.970 15.970 11.970 7.980 3.980 578 1E51N055A 4/24/01 AL 3.980 7.980 11.970 15.970 19.970 15.970 11.970 7.980 3.980 579 1E51N055A 10/29/99 AF 4.000 8.010 11.990 15.990 19.970 15.980 11.990 8.000 4.000 580 1E51N055A 10/29/99 AL 4.000 8.010 11.990 15.990 19.970 15.980 11.990 8.000 4.000

DRIFT ANALYSIS ENGINEERING DEPARTMENT GRAND GULF NUCLEAR STATION Rosemount Range Codes 5 - 8 Gage Pressure Transmitters Input Data JC-Q1111-09019 Rev. 0 Page 60 of 134 AF/AL Data Seq.

AFI Pt 1 Pt2 Pt 3 Pt4 Pt 5 Pt6 Pt7 Pt8 Pt9 Comments ID TaglD Date AL (0% Up)

(25% Up)

(50% Up)

(75% Up)

(100%

(75% Dn) (50% Dn) (25% On)

(0% On) 581 1E51N055A 4/20/98 AF 4.000 7.970 11.940 15.920 19.910 15.920 11.940 7.970 4.000 582 1E51N055A 4/20/98 AL 3.990 7.990 11.990 15.990 19.990 15.990 11.990 7.990 3.990 583 1E51N055B 11/4/10 AF 3.990 7.990 11.990 15.980 19.980 15.980 11.990 7.990 3.990 584 1E51N055B 11/4/10 AL 3.990 7.990 11.990 15.980 19.980 15.980 11.990 7.990 3.990 585 1E51N055B 1/22/09 AF 4.000 8.000 12.000 16.000 20.000 16.000 12.000 8.000 4.000 586 1E51N055B 1/22/09 AL 4.000 8.000 12.000 16.000 20.000 16.000 12.000 8.000 4.000 587 1E51N055B 8/10/07 AF 3.990 7.990 11.990 15.990 20.000 15.990 11.990 7.990 3.990 588 1E51N055B 8/10/07 AL 3.990 7.990 11.990 15.990 20.000 15.990 11.990 7.990 3.990 589 1E51N055B 2/9/06 AF 3.990 7.990 11.990 15.990 20.000 15.990 11.990 7.990 3.990 590 1E51N055B 2/9/06 AL 3.990 7.990 11.990 15.990 20.000 15.990 11.990 7.990 3.990 591 1E51N055B 5/4/04 AF 3.990 7.990 11.990 16.000 20.020 16.000 11.990 7.990 4.000 592 1E51 N055B 5/4/04 AL 3.990 7.990 11.990 16.000 20.020 16.000 11.990 7.990 4.000 593 1E51N055B 11/20/02 AF 3.990 8.000 12.000 16.000 20.020 16.010 12.000 8.000 4.000 594 1E51N055B 11/20/02 AL 3.990 8.000 12.000 16.000 20.020 16.010 12.000 8.000 4.000 595 1E51N055B 4/20/01 AF 3.990 8.000 11.980 16.000 20.010 16.000 11.980 7.990 4.000 596 1E51N055B 4/20/01 AL 3.990 8.000 11.980 16.000 20.010 16.000 11.980 7.990 4.000 597 1E51N055B 11/16/99 AF 3.990 7.990 12.000 16.010 20.020 16.010 11.990 7.990 3.990 598 1E51N055B 11/16/99 AL 3.990 7.990 12.000 16.010 20.020 16.010 11.990 7.990 3.990 599 1E51N055B 4/20/98 AF 4.000 7.990 12.000 16.010 20.020 16.010 12.000 8.000 3.990 600 1E51N055B 4/20/98 AL 4.000 7.990 12.000 16.010 20.020 16.010 12.000 8.000 3.990 601 1E51N055E 2/26/10 AF 3.970 7.970 11.970 15.980 20.000 15.990 11.990 8.000 3.980 602 1E51N055E 2/26/10 AL 3.970 7.970 11.970 15.980 20.000 15.990 11.990 8.000 3.980

DRIFT ANALYSIS ENGINEERING DEPARTMENT GRAND GULF NUCLEAR STATION Rosemount Range Codes 5 - 8 Gage Pressure Transmitters Input Data JC-Q1111-09019 Rev. 0 Page 61 of 134 AF/AL Data Seq.

AFI Pt 1 Pt2 Pt3 Pt4 Pt5 Pt6 Pt7 Pt8 Pt9 Comments 10 Tag 10 Oate AL (0"10 Up)

(25"10 Up)

(50"10 Up)

(75"10 Up)

(100"10 (75"10 On) 1(50"10 On) (25"10 On)

(0"10 On) 603 1E51N055E 7/3/08 AF 3.980 7.980 11.980 15.990 20.010 16.000 12.000 7.990 3.990 604 1E51N055E 7/3/08 AL 3.980 7.980 11.980 15.990 20.010 16.000 12.000 7.990 3.990 605 1E51N055E 10/10/06 AF 3.980 7.980 11.990 15.990 19.990 16.000 11.990 7.990 3.990 606 1E51N055E 10/10/06 AL 3.980 7.980 11.990 15.990 19.990 16.000 11.990 7.990 3.990 607 1E51N055E 12/21/04 AF 3.970 7.980 11.980 15.990 20.000 15.990 11.980 7.980 3.980 608 1E51N055E 12/21/04 AL 3.970 7.980 11.980 15.990 20.000 15.990 11.980 7.980 3.980 609 1E51N055E 2/19/03 AF 3.960 7.970 11.970 15.980 19.980 15.990 11.990 7.980 3.970 610 1E51N055E 2/19/03 AL 3.960 7.970 11.970 15.980 19.980 15.990 11.990 7.980 3.970 611 1E51N055E 4/25/01 AF 3.980 8.000 12.010 16.010 20.030 16.020 12.020 8.010 3.990 612 1E51N055E 4/25/01 AL 3.980 8.000 12.010 16.010 20.030 16.020 12.020 8.010 3.990 613 1E51N055E 10/29/99 AF 3.980 7.990 11.990 16.020 20.000 16.010 12.000 7.990 3.980 614 1E51N055E 10/29/99 AL 3.980 7.990 11.990 16.020 20.000 16.010 12.000 7.990 3.980 615 1E51N055E 4/20/98 AF 3.960 7.980 11.980 16.000 20.010 16.010 12.010 7.990 3.970 616 1E51N055E 4/20/98 AL 3.960 7.980 11.980 16.000 20.010 16.010 12.010 7.990 3.970 617 1E51N055F 6/9/09 AF 4.010 8.000 11.990 16.000 20.010 16.000 12.000 8.010 4.020 618 1E51N055F 6/9/09 AL 4.010 8.000 11.990 16.000 20.010 16.000 12.000 8.010 4.020 619 1E51N055F 9/20/07 AF 4.010 8.010 12.010 16.010 20.020 16.010 12.010 8.010 4.020 620 1E51N055F 9/20/07 AL 4.010 8.010 12.010 16.010 20.020 16.010 12.010 8.010 4.020 621 1E51N055F 1/24/06 AF 4.010 8.000 11.990 16.000 20.010 16.000 11.990 8.000 4.010 622 1E51N055F 1/24/06 AL 4.010 8.000 11.990 16.000 20.010 16.000 11.990 8.000 4.010 623 1E51N055F 5/6/04 AF 3.990 7.990 11.990 15.990 20.000 15.990 11.990 8.000 4.000 624 1E51N055F 5/6/04 AL 3.990 7.990 11.990 15.990 20.000 15.990 11.990 8.000 4.000

DRIFT ANALYSIS ENGINEERING DEPARTMENT GRAND GULF NUCLEAR STATION Rosemount Range Codes 5 - 8 Gage Pressure Transmitters Input Data JC-Q1111-09019 Rev. 0 Page 62 of 134 AF/AL Data Seq.

AFI Pt 1 Pt 2 Pt 3 Pt4 Pt5 Pt6 Pt7 PtS Pt9 Comments 10 Tag 10 Date AL (0% Up)

(25% Up) *(50% Up) (75% Up)

(100%

(75% On) *(50% On) (25% On)

(0% On) 625 1E51N055F 11/21/02 AF 4.010 8.000 11.990 16.000 20.000 16.000 11.990 8.000 4.010 626 1E51N055F 11/21/02 AL 4.010 8.000 11.990 16.000 20.000 16.000 11.990 8.000 4.010 627 1E51N055F 4/20/01 AF 3.990 8.000 11.990 16.000 20.020 15.990 11.980 7.990 4.010 628 1E51N055F 4/20/01 AL 3.990 8.000 11.990 16.000 20.020 15.990 11.980 7.990 4.010 629 1E51N055F 11/16/99 AF 4.000 8.020 12.020 16.030 20.040 16.040 12.030 8.020 4.000 630 1E51N055F 11/16/99 AL 4.000 7.990 11.980 16.000 20.010 16.000 11.980 7.990 4.000 631 1E51N055F 4/20/98 AF 3.990 7.970 11.960 15.950 19.950 15.950 11.960 7.960 3.990 632 1E51N055F 4/20/98 AL 4.000 8.000 11.990 15.990 20.000 16.000 12.000 8.000 4.000

DRIFT ANALYSIS ENGINEERING DEPARTMENT GRAND GULF NUCLEAR STATION Rosemount Range Codes 5 - 8 Gage Pressure Transmitters Data Conversion JC-Q1111-09019 Rev. 0 Page 63 of 134 IDENTIFYING INFORMATION ACTUAL AF/AL RAW VALUES Seq. 10 Tag 10 1

2 3

4 5

6 7

8 9

Date AF/AL (0% Up)

(25% Up)

(50% Up)

(75% Up)

(100% Up)

(75% On)

(50% On)

(25% On)

(0% On) 1 1B21N201A 6/17/09 AF 4.020 8.010 12.000 16.000 19.990 16.000 12.010 8.010 4.020 2

1B21N201A 6/17109 AL 4.020 8.010 12.000 16.000 19.990 16.000 12.010 8.010 4.020 3

1B21N201A 8/28/07 AF 4.020 8.010 12.000 15.990 19.980 15.990 12.000 8.010 4.020 4

1B21N201A 8/28/07 AL 4.020 8.010 12.000 15.990 19.980 15.990 12.000 8.010 4.020 5

1B21N201A 11/8/05 AF 3.980 8.020 12.050 16.100 20.210 16.120 12.050 8.030 3.980 6

1B21N201A 11/8/05 AL 4.010 8.000 12.000 16.000 20.000 16.000 12.000 8.000 4.010 7

1B21N201A 5/11/04 AF 4.010 8.020 12.030 16.040 20.050 16.040 12.030 8.020 4.020 8

1B21N201A 5/11/04 AL 3.980 7.990 12.000 16.010 20.020 16.010 12.000 7.990 3.990 9

1B21N201A 11/25/02 AF 4.010 8.010 12.010 16.010 20.020 16.020 12.020 8.010 4.010 10 1B21N201A 11/25/02 AL 4.010 8.010 12.010 16.010 20.020 16.020 12.020 8.010 4.010 11 1B21N201A 4/24/01 AF 4.070 8.000 11.990 15.980 19.980 16.000 12.000 8.000 4.070 12 1B21N201A 4/24/01 AL 4.020 7.980 11.990 16.000 20.010 16.000 11.990 7.970 4.030 13 1B21N201A 10/28/99 AF 3.998 7.990 12.021 16.002 19.982 16.009 12.013 7.987 4.001 14 1B21N201A 10/28/99 AL 3.998 7.990 12.021 16.002 19.982 16.009 12.013 7.987 4.001 15 1B21N201A 4/21/98 AF 4.010 8.000 12.000 15.990 19.990 15.990 12.000 8.000 4.010 16 1B21N201A 4/21/98 AL 4.010 8.000 12.000 15.990 19.990 15.990 12.000 8.000 4.010 17 1B21N201B 1213/10 AF 4.030 8.030 12.010 16.010 20.010 16.010 12.010 8.030 4.030 18 1B21N201B 12/3/10 AL 4.030 8.030 12.010 16.010 20.010 16.010 12.010 8.030 4.030 19 1B21N201B 3/31/09 AF 4.020 8.020 12.010 16.010 20.010 16.010 12.010 8.020 4.020 20 1B21N201B 3/31/09 AL 4.020 8.020 12.010 16.010 20.010 16.010 12.010 8.020 4.020 21 1B21N201B 10/12/07 AF 4.020 8.010 12.014 16.000 20.010 16.010 12.010 8.010 4.020 22 1B21N201B 10/12/07 AL 4.020 8.010 12.014 16.000 20.010 16.010 12.010 8.010 4.020 23 1B21N201B 3/8/06 AF 4.020 8.010 12.014 16.020 20.000 16.020 12.010 8.020 4.020 24 1B21N201B 3/8/06 AL 4.020 8.010 12.014 16.020 20.000 16.020 12.010 8.020 4.020 25 1B21N201B 7/15/04 AF 4.020 8.020 12.020 16.020 20.020 16.020 12.020 8.030 4.020 26 1B21N201B 7/15/04 AL 4.020 8.020 12.020 16.020 20.020 16.020 12.020 8.030 4.020 27 1B21N201B 10/24/02 AF 4.020 7.990 12.010 15.980 19.980 15.980 11.990 7.990 4.000 28 1B21N201B 10/24/02 AL 4.020 7.990 12.010 15.980 19.980 15.980 11.990 7.990 4.000 29 1B21N201B 4/23/01 AF 4.010 8.010 12.010 16.010 20.010 16.010 12.010 8.010 4.010 30 1B21N201B 4/23/01 AL 4.010 8.010 12.010 16.010 20.010 16.010 12.010 8.010 4.010 31 1B21N201B 11/5/99 AF 4.010 8.010 12.000 15.990 20.010 16.010 12.030 8.020 4.020 32 1B21N201B 11/5/99 AL 4.010 8.010 12.000 15.990 20.010 16.010 12.030 8.020 4.020 33 1B21N201B 4/16/98 AF 4.000 8.000 12.020 16.020 20.020 16.010 12.020 8.000 4.010 34 1B21N201B 4/16/98 AL 4.000 8.000 12.020 16.020 20.020 16.010 12.020 8.000 4.010 35 1C61N102 8/12109 AF 4.000 7.990 11.990 16.000 19.990 16.000 11.990 8.000 4.000 36 1C61N102 8/12/09 AL 4.000 7.990 11.990 16.000 19.990 16.000 11.990 8.000 4.000 37 1C61N102 2/15/08 AF 3.990 7.990 12.000 16.000 20.010 16.010 12.000 8.000 3.990 38 1C61N102 2115/08 AL 3.990 7.990 12.000 16.000 20.010 16.010 12.000 8.000 3.990 39 1C61N102 8/31/06 AF 3.970 7.970 11.980 15.990 20.000 16.000 11.990 7.970 3.970 40 1C61N102 8/31/06 AL 3.970 7.970 11.980 15.990 20.000 16.000 11.990 7.970 3.970 41 1C61N102 1/19/05 AF 3.960 7.960 11.960 15.970 19.980 15.970 11.970 7.960 3.960 42 1C61N102 1/19/05 AL 3.960 7.960 11.960 15.970 19.980 15.970 11.970 7.960 3.960 43 1C61N102 817103 AF 4.000 7.990 11.990 15.990 19.990 15.990 12.000 8.000 4.000 44 1C61N102 817/03 AL 4.000 7.990 11.990 15.990 19.990 15.990 12.000 8.000 4.000 45 1C61N102 218/02 AF 4.020 8.020 12.020 16.020 20.030 16.030 12.030 8.030 4.020 46 1C61N102 218/02 AL 4.000 8.000 12.000 16.000 20.000 16.000 12.000 8.000 4.000 47 1C61N102 8/15/00 AF 4.000 8.000 12.020 16.000 20.010 16.010 12.020 8.010 4.010

DRIFT ANALYSIS ENGINEERING DEPARTMENT GRAND GULF NUCLEAR STATION Rosemount Range Codes 5 - 8 Gage Pressure Transmitters Data Conversion JC-Q1111-09019 Rev. 0 Page 64 of 134 IDENTIFYING INFORMATION ACTUAL AF/AL RAW VALUES Seq. to Tag 10 1

2 3

4 5

6 7

8 9

Date AF/AL (0% Up)

(25% Up)

(50% Up)

(75% Up)

(100% Up)

(75% On)

(50% On)

(25% On)

(0% On) 48 1C61N102 8/15/00 AL 4.000 8.000 12.020 16.000 20.010 16.010 12.020 8.010 4.010 49 1C61N102 3/29/99 AF 4.030 8.010 12.010 16.010 20.020 16.010 12.010 8.010 4.030 50 1C61N102 3/29/99 AL 4.030 8.010 12.010 16.010 20.020 16.010 12.010 8.010 4.030 51 1E12N053A 8112/09 AF 4.190 8.000 12.000 16.000 20.000 16.000 12.010 8.010 4.180 52 1E12N053A 8/12/09 AL 4.190 8.000 12.000 16.000 20.000 16.000 12.010 8.010 4.180 53 1E12N053A 2/15/08 AF 4.130 7.960 11.950 15.950 19.950 15.960 11.960 7.960 4.150 54 1E12N053A 2/15/08 AL 4.190 8.000 11.990 15.990 19.990 16.000 12.000 8.000 4.190 55 1E12N053A 8/30/06 AF 4.150 7.970 11.980 15.970 19.970 15.980 11.970 7.970 4.160 56 1E12N053A 8/30/06 AL 4.150 7.970 11.980 15.970 19.970 15.980 11.970 7.970 4.160 57 1E12N053A 3/17105 AF 4.150 7.970 11.960 15.960 19.960 15.970 11.970 7.980 4.160 58 1E12N053A 3/17/05 AL 4.150 7.970 11.960 15.960 19.960 15.970 11.970 7.980 4.160 59 1E12N053A 10/3/03 AF 4.150 7.970 11.970 15.970 19.970 15.980 11.980 7.980 4.150 60 1E12N053A 10/3/03 AL 4.150 7.970 11.970 15.970 19.970 15.980 11.980 7.980 4.150 61 1E12N053A 4/17/02 AF 4.160 8.000 12.000 16.000 20.000 16.010 12.010 8.000 4.160 62 1E12N053A 4/17/02 AL 4.160 8.000 12.000 16.000 20.000 16.010 12.010 8.000 4.160 63 1E12N053A 10/16/00 AF 4.170 7.990 12.010 16.000 20.010 16.000 12.010 7.990 4.170 64 1E12N053A 10/16/00 AL 4.170 7.990 12.010 16.000 20.010 16.000 12.010 7.990 4.170 65 1E12N053A 3/22/99 AF 4.150 7.980 12.010 15.990 20.040 16.010 12.010 7.980 4.160 66 1E12N053A 3/22/99 AL 4.160 7.990 12.010 16.010 19.990 16.000 12.000 7.980 4.160 67 1E12N053A 8/26/97 AF 4.169 7.990 12.010 16.008 20.012 16.011 12.013 7.995 4.169 68 1E12N053A 8/26/97 AL 4.169 7.990 12.010 16.008 20.012 16.011 12.013 7.995 4.169 69 1E12N053B 12114/09 AF 4.140 8.000 11.990 15.990 19.990 15.990 12.000 8.010 4.150 70 1E12N053B 12114/09 AL 4.140 8.000 11.990 15.990 19.990 15.990 12.000 8.010 4.150 71 1E12N053B 5/29/08 AF 4.160 8.010 12.000 16.000 20.000 16.020 12.010 8.020 4.200 72 1E12N053B 5/29/08 AL 4.160 8.010 12.000 16.000 20.000 16.020 12.010 8.020 4.200 73 1E12N053B 11/29/06 AF 4.160 7.970 11.960 15.950 19.950 15.950 11.960 7.970 4.160 74 1E12N053B 11/29/06 AL 4.200 8.000 11.990 15.990 19.980 16.000 12.000 8.010 4.200 75 1E12N053B 5/20/05 AF 4.160 7.970 11.970 15.970 19.970 15.980 11.980 7.980 4.160 76 1E12N053B 5/20/05 AL 4.160 7.970 11.970 15.970 19.970 15.980 11.980 7.980 4.160 77 1E12N053B 11/20/03 AF 4.160 7.970 11.960 15.970 19.970 15.980 11.980 7.990 4.160 78 1E12N053B 11/20/03 AL 4.160 7.970 11.960 15.970 19.970 15.980 11.980 7.990 4.160 79 1E12N053B 7/17/02 AF 4.180 7.990 11.980 15.980 19.980 15.990 12.000 8.000 4.190 80 1E12N053B 7/17/02 AL 4.180 7.990 11.980 15.980 19.980 15.990 12.000 8.000 4.190 81 1E12N053B 9/28/00 AF 4.180 7.980 12.000 16.000 19.980 16.000 11.990 7.990 4.180 82 1E12N053B 9/28/00 AL 4.180 7.980 12.000 16.000 19.980 16.000 11.990 7.990 4.180 83 1E12N053B 3/18/99 AF 4.160 8.000 11.990 16.000 19.990 16.010 12.010 8.010 4.150 84 1E12N053B 3118/99 AL 4.160 8.000 11.990 16.000 19.990 16.010 12.010 8.010 4.150 85 1E12N053B 8/20/97 AF 4.176 8.006 12.021 16.013 20.038 16.029 12.025 8.017 4.181 86 1E12N053B 8/20/97 AL 4.176 8.006 12.021 16.013 20.038 16.029 12.025 8.017 4.181 87 1E12N053C 11/4/10 AF 4.020 7.980 11.980 15.980 19.980 15.990 11.990 7.990 4.030 88 1E12N053C 11/4/10 AL 4.020 7.980 11.980 15.980 19.980 15.990 11.990 7.990 4.030 89 1E12N053C 5/11/09 AF 4.030 7.990 12.000 15.990 19.990 16.000 12.010 8.000 4.030 90 1E12N053C 5/11/09 AL 4.030 7.990 12.000 15.990 19.990 16.000 12.010 8.000 4.030 91 1E12N053C 9/17/07 AF 4.020 7.970 11.970 15.970 19.970 15.990 11.990 7.990 4.030 92 1E12N053C 9/17/07 AL 4.020 7.970 11.970 15.970 19.970 15.990 11.990 7.990 4.030 93 1E12N053C 1/23/06 AF 4.050 7.990 11.980 15.980 19.980 15.990 12.000 8.000 4.050 94 1E12N053C 1/23/06 AL 4.050 7.990 11.980 15.980 19.980 15.990 12.000 8.000 4.050

DRIFT ANALYSIS ENGINEERING DEPARTMENT GRAND GULF NUCLEAR STATION Rosemount Range Codes 5 - 8 Gage Pressure Transmitters Data Conversion JC-Q1111-09019 Rev. 0 Page 65 of 134 IDENTIFYING INFORMATION ACTUAL AF/AL RAW VALUES 1

2 3

4 5

6 7

8 9

Seq. 10 Tag 10 Date AF/AL (0% Up)

(25% Up)

(50% Up)

(75% Up)

(100% Up)

(75% On)

(50% On)

(25% On)

(0% On) 95 1E12N053C 417104 AF 4.040 7.990 11.990 15.990 19.980 16.000 12.000 8.000 4.040 96 1E12N053C 4/7/04 AL 4.040 7.990 11.990 15.990 19.980 16.000 12.000 8.000 4.040 97 1E12N053C 7/17/02 AF 4.040 8.000 12.000 16.000 19.990 16.010 12.010 8.010 4.040 98 1E12N053C 7/17/02 AL 4.040 8.000 12.000 16.000 19.990 16.010 12.010 8.010 4.040 99 1E12N053C 10/24/00 AF 4.040 7.990 11.990 15.970 19.990 16.000 11.990 7.990 4.040 100 1E12N053C 10/24/00 AL 4.040 7.990 11.990 15.970 19.990 16.000 11.990 7.990 4.040 101 1E12N053C 3/18/99 AF 4.040 8.000 12.000 16.000 19.990 16.010 12.010 8.020 4.040 102 1E12N053C 3/18/99 AL 4.040 8.000 12.000 16.000 19.990 16.010 12.010 8.020 4.040 103 1E12N053C 8/20/97 AF 4.053 8.021 11.998 16.022 20.010 15.984 12.030 8.011 4.058 104 1E12N053C 8/20/97 AL 4.053 8.021 11.998 16.022 20.010 15.984 12.030 8.011 4.058 105 1E12N055A 12122/09 AF 4.340 8.020 12.010 16.020 20.030 16.020 12.010 8.020 4.340 106 1E12N055A 12122/09 AL 4.340 8.020 12.010 16.020 20.030 16.020 12.010 8.020 4.340 107 1E12N055A 6/30/08 AF 4.320 7.990 11.980 15.990 20.020 15.990 11.990 7.990 4.320 108 1E12N055A 6/30/08 AL 4.320 7.990 11.980 15.990 20.020 15.990 11.990 7.990 4.320 109 1E12N055A 9114/06 AF 4.330 8.000 11.990 16.010 20.030 16.010 12.000 8.010 4.330 110 1E12N055A 9/14/06 AL 4.330 8.000 11.990 16.010 20.030 16.010 12.000 8.010 4.330 111 1E12N055A 1/17/05 AF 4.290 7.960 11.950 15.940 19.970 15.950 11.950 7.960 4.300 112 1E12N055A 1/17/05 AL 4.330 7.990 11.990 15.990 20.020 15.990 11.990 8.000 4.330 113 1E12N055A 9/3/03 AF 4.300 7.980 11.970 15.980 19.990 15.980 11.980 7.980 4.290 114 1E12N055A 9/3/03 AL 4.300 7.980 11.970 15.980 19.990 15.980 11.980 7.980 4.290 115 1E12N055A 3/8/02 AF 4.290 8.030 11.990 16.020 20.030 15.990 11.990 8.030 4.290 116 1E12N055A 3/8/02 AL 4.310 7.990 11.990 15.990 20.010 15.990 11.990 8.000 4.310 117 1E12N055A 10/4/00 AF 4.330 8.020 12.030 16.040 20.070 16.030 12.040 8.050 4.330 118 1E12N055A 10/4/00 AL 4.300 8.010 11.990 16.000 20.000 16.000 12.010 8.010 4.310 119 1E12N055A 4/11/99 AF 4.343 8.015 12.000 15.993 20.026 15.985 12.003 7.985 4.339 120 1E12N055A 4/11/99 AL 4.343 8.015 12.000 15.993 20.026 15.985 12.003 7.985 4.339 121 1E12N055A 8/30/97 AF 4.334 8.015 11.992 15.988 20.010 15.981 12.011 8.022 4.337 122 1E12N055A 8/30/97 AL 4.334 8.015 11.992 15.988 20.010 15.981 12.011 8.022 4.337 123 1E12N055B 1/21110 AF 4.330 8.000 11.980 15.980 19.990 15.980 11.980 8.000 4.330 124 1E12N055B 1/21/10 AL 4.330 8.000 11.980 15.980 19.990 15.980 11.980 8.000 4.330 125 1E12N055B 5/29/08 AF 4.330 7.980 11.960 15.970 20.000 15.970 11.960 7.980 4.330 126 1E12N055B 5/29/08 AL 4.330 7.980 11.960 15.970 20.000 15.970 11.960 7.980 4.330 127 1E12N055B 11/29/06 AF 4.320 7.940 11.930 15.930 19.940 15.930 11.930 7.950 4.320 128 1E12N055B 11/29/06 AL 4.340 7.990 11.970 15.990 20.010 15.990 11.970 7.990 4.340 129 1E12N055B 5/20/05 AF 4.340 7.980 11.960 15.970 19.980 15.970 11.970 7.990 4.340 130 1E12N055B 5/20/05 AL 4.340 7.980 11.960 15.970 19.980 15.970 11.970 7.990 4.340 131 1E12N055B 11/19/03 AF 4.340 7.970 11.950 15.950 19.980 15.960 11.960 7.970 4.330 132 1E12N055B 11/19/03 AL 4.350 7.990 11.970 15.980 20.000 15.980 11.970 7.990 4.350 133 1E12N055B 6/4/02 AF 4.320 7.980 11.990 15.980 19.940 15.990 12.000 7.990 4.320 134 1E12N055B 6/4/02 AL 4.330 8.000 11.990 16.000 20.020 16.000 11.990 8.000 4.330 135 1E12N055B 12/5/00 AF 4.320 7.990 11.980 16.000 19.990 15.990 11.980 7.980 4.320 136 1E12N055B 12/5/00 AL 4.320 7.990 11.980 16.000 19.990 15.990 11.980 7.980 4.320 137 1E12N055B 5/26/99 AF 4.320 8.000 12.016 16.017 19.969 16.035 12.017 8.019 4.321 138 1E12N055B 5/26/99 AL 4.320 8.000 12.016 16.017 19.969 16.035 12.017 8.019 4.321 139 1E12N055B 10/16/97 AF 4.300 7.990 11.990 15.990 20.000 15.990 12.000 7.980 4.310 140 1E12N055B 10/16/97 AL 4.300 7.990 11.990 15.990 20.000 15.990 12.000 7.980 4.310 141 1E12N055C 1/20/10 AF 4.070 8.030 12.020 16.020 20.020 16.020 12.020 8.030 4.070

DRIFT ANALYSIS ENGINEERING DEPARTMENT GRAND GULF NUCLEAR STATION Rosemount Range Codes 5 - 8 Gage Pressure Transmitters Data Conversion JC-Q1111-09019 Rev. 0 Page 66 of 134 IDENTIFYING INFORMATION ACTUAL AFIAL RAW VALUES Seq. 10 Tag 10 Date AFIAL 1

2 3

4 5

6 7

8 9

(0% Up)

(25% Up)

(50% Up)

(75% Up)

(100% Up)

(75% On)

(50% On)

(25% On)

(0% On) 142 1E12N055C 1/20/10 AL 4.070 8.030 12.020 16.020 20.020 16.020 12.020 8.030 4.070 143 1E12N055C 5/29/08 AF 4.070 8.010 12.000 16.000 20.000 16.000 12.000 8.010 4.070 144 1E12N055C 5/29/08 AL 4.070 8.010 12.000 16.000 20.000 16.000 12.000 8.000 4.070 145 1E12N055C 11/29/06 AF 3.990 7.960 11.940 15.920 19.930 15.920 11.930 7.980 4.000 146 1E12N055C 11/29/06 AL 4.040 8.020 12.010 16.000 20.000 16.000 12.010 8.020 4.040 147 1E12N055C 5/20/05 AF 4.070 8.010 12.000 15.990 19.990 15.990 12.000 8.010 4.070 148 1E12N055C 5/20/05 AL 4.070 8.010 12.000 15.990 19.990 15.990 12.000 8.010 4.070 149 1E12N055C 11/19/03 AF 4.080 8.010 12.000 16.000 20.000 16.000 12.010 8.020 4.080 150 1E12N055C 11/19/03 AL 4.080 8.010 12.000 16.000 20.000 16.000 12.010 8.020 4.080 151 1E12N055C 7/3/02 AF 4.050 7.980 11.970 15.970 19.960 15.970 11.970 7.980 4.040 152 1E12N055C 7/3/02 AL 4.070 8.010 12.000 15.990 19.970 15.990 12.000 8.010 4.070 153 1E12N055C 1216/00 AF 4.050 7.990 11.990 15.980 19.970 15.980 11.980 7.990 4.050 154 1E12N055C 12/6/00 AL 4.050 7.990 11.990 15.980 19.970 15.980 11.980 7.990 4.050 155 1E12N055C 5/27/99 AF 4.060 8.010 12.020 16.000 19.990 16.010 12.040 8.010 4.050 156 1E12N055C 5/27/99 AL 4.060 8.010 12.020 16.000 19.990 16.010 12.040 8.010 4.050 157 1E12N055C 10/16/97 AF 4.050 7.980 11.960 15.960 19.970 15.960 11.970 7.970 4.050 158 1E12N055C 10/16/97 AL 4.050 7.980 11.960 15.960 19.970 15.960 11.970 7.970 4.050 159 1E12N056A 12121/09 AF 4.330 8.020 12.030 16.040 20.030 16.040 12.030 8.020 4.330 160 1E12N056A 12121/09 AL 4.310 8.000 12.000 16.000 20.000 16.000 12.000 8.000 4.310 161 1E12N056A 6/30/08 AF 4.240 7.940 11.950 15.950 19.950 15.950 11.950 7.940 4.240 162 1E12N056A 6/30/08 AL 4.310 8.000 12.010 16.020 20.010 16.020 12.020 8.000 4.310 163 1E12N056A 9/15/06 AF 4.290 7.990 12.000 16.000 20.000 16.000 12.000 7.990 4.280 164 1E12N056A 9/15/06 AL 4.290 7.990 12.000 16.000 20.000 16.000 12.000 7.990 4.280 165 1E12N056A 1/17/05 AF 4.310 7.980 11.990 15.980 20.000 15.990 12.000 7.990 4.300 166 1E12N056A 1/17105 AL 4.310 7.980 11.990 15.980 20.000 15.990 12.000 7.990 4.300 167 1E12N056A 8/6/03 AF 4.300 7.980 12.000 16.000 20.010 16.010 12.010 7.980 4.300 168 1E12N056A 8/6/03 AL 4.300 7.980 12.000 16.000 20.010 16.010 12.010 7.980 4.300 169 1E12N056A 218/02 AF 4.300 7.940 11.910 15.900 19.940 15.900 11.900 7.920 4.290 170 1E12N056A 218/02 AL 4.310 8.000 11.990 16.010 20.000 16.010 11.990 7.990 4.310 171 1E12N056A 10/4/00 AF 4.290 8.000 11.990 16.000 20.030 16.010 12.010 7.990 4.300 172 1E12N056A 10/4/00 AL 4.290 8.000 11.990 16.000 20.030 16.010 12.010 7.990 4.300 173 1E12N056A 4/11/99 AF 4.285 7.982 11.980 15.977 20.001 15.975 11.981 7.976 4.301 174 1E12N056A 4/11/99 AL 4.285 7.982 11.980 15.977 20.001 15.975 11.981 7.976 4.301 175 1E12N056A 8/30/97 AF 4.335 7.976 11.970 15.951 20.007 15.948 11.957 8.006 4.344 176 1E12N056A 8/30/97 AL 4.304 7.988 11.976 15.974 20.009 15.971 11.976 7.987 4.304 177 1E12N056B 215/10 AF 4.350 8.030 12.010 16.010 20.020 16.020 12.020 8.030 4.340 178 1E12N056B 215/10 AL 4.350 8.030 12.010 16.010 20.020 16.020 12.020 8.030 4.340 179 1E12N056B 7/8/08 AF 4.270 7.910 11.900 15.900 19.940 15.900 11.900 7.910 4.270 180 1E12N056B 7/8/08 AL 4.320 7.970 11.960 15.970 19.990 15.970 11.960 7.970 4.320 181 1E12N056B 1/11/07 AF 4.320 7.990 11.980 15.980 19.990 15.990 11.980 7.980 4.330 182 1E12N056B 1/11/07 AL 4.320 7.990 11.980 15.980 19.990 15.990 11.980 7.980 4.330 183 1E12N056B 7/14/05 AF 4.330 7.990 11.990 15.990 20.030 15.990 11.990 7.990 4.330 184 1E12N056B 7/14/05 AL 4.330 7.990 11.990 15.990 20.030 15.990 11.990 7.990 4.330 185 1E12N056B 10/22/03 AF 4.300 7.920 11.980 15.860 19.870 15.860 11.880 7.920 4.300 186 1E12N056B 10/22103 AL 4.320 7.990 11.970 15.970 20.010 15.970 11.970 7.990 4.320 187 1E12N056B 4/23/02 AF 4.340 8.030 12.050 16.080 20.100 16.080 12.050 8.070 4.360

DRIFT ANALYSIS ENGINEERING DEPARTMENT GRAND GULF NUCLEAR STATION Rosemount Range Codes 5 - 8 Gage Pressure Transmitters Data Conversion JC-Q1111-09019 Rev. 0 Page 67 of 134 IDENTIFYING INFORMATION ACTUAL AF/AL RAW VALUES 1

2 3

4 5

6 7

8 9

Seq. 10 Tag 10 Date AF/AL (0% Up)

(25% Up)

(50% Up)

(75% Up)

(100% Up)

(75% On)

(50% On)

(25% On)

(0% On) 188 1E12N056B 4/23/02 AL 4.320 8.010 11.980 15.980 20.010 15.990 11.990 8.000 4.320 189 1E12N056B 12/6/00 AF 4.350 8.010 12.000 15.970 20.010 15.980 12.010 8.010 4.350 190 1E12N056B 12/6/00 AL 4.350 8.010 12.000 15.970 20.010 15.980 12.010 8.010 4.350 191 1E12N056B 5/26/99 AF 4.343 8.023 12.024 16.026 20.025 16.022 12.022 8.004 4.359 192 1E12N056B 5/26/99 AL 4.343 8.023 12.024 16.026 20.025 16.022 12.022 8.004 4.359 193 1E12N056B 10/16/97 AF 4.350 8.040 12.060 16.090 20.150 16.090 12.070 8.060 4.350 194 1E12N056B 10/16/97 AL 4.350 7.990 11.980 15.990 20.040 16.000 11.970 7.990 4.350 195 1E12N056C 4/6/10 AF 4.000 7.930 11.930 15.930 19.930 15.920 11.930 7.920 3.990 196 1E12N056C 4/6/10 AL 4.020 7.980 11.990 16.000 20.020 16.000 11.990 7.980 4.020 197 1E12N056C 7/8/08 AF 4.050 8.000 12.000 16.000 20.020 16.000 12.000 8.000 4.050 198 1E12N056C 7/8/08 AL 4.050 8.000 12.000 16.000 20.020 16.000 12.000 8.000 4.050 199 1E12N056C 1/10/07 AF 4.060 8.000 12.000 16.000 20.000 16.000 12.010 8.000 4.050 200 1E12N056C 1/10/07 AL 4.060 8.000 12.000 16.000 20.000 16.000 12.010 8.000 4.050 201 1E12N056C 6/29/05 AF 4.050 8.000 11.970 15.950 19.940 15.950 11.960 7.980 4.050 202 1E12N056C 6/29/05 AL 4.050 7.990 11.990 15.970 19.990 15.970 11.990 7.990 4.050 203 1E12N056C 10/22/03 AF 4.050 8.000 11.990 15.980 19.980 15.980 11.990 8.000 4.050 204 1E12N056C 10/22/03 AL 4.050 8.000 11.990 15.980 19.980 15.980 11.990 8.000 4.050 205 1E12N056C 7/3/02 AF 4.040 7.980 11.980 15.970 19.970 15.970 11.980 8.000 4.040 206 1E12N056C 7/3/02 AL 4.040 7.980 11.980 15.970 19.970 15.970 11.980 8.000 4.040 207 1E12N056C 12/6/00 AF 4.050 7.990 11.950 15.960 19.950 15.950 11.970 8.000 4.050 208 1E12N056C 12/6/00 AL 4.060 8.010 11.990 15.990 19.990 15.990 12.000 8.010 4.060 209 1E12N056C 5/26/99 AF 4.014 8.004 12.031 15.985 19.991 16.011 12.037 8.019 4.035 210 1E12N056C 5/26/99 AL 4.014 8.004 12.031 15.985 19.991 16.011 12.037 8.019 4.035 211 1E12N056C 10/16/97 AF 4.050 8.010 11.970 15.970 19.980 15.970 11.970 7.990 4.050 212 1E12N056C 10/16/97 AL 4.050 8.010 11.970 15.970 19.980 15.970 11.970 7.990 4.050 213 1E12N057 2/9/10 AF 3.990 7.990 12.000 15.990 19.990 15.990 12.000 8.000 3.990 214 1E12N057 2/9/10 AL 3.990 7.990 12.000 15.990 19.990 15.990 12.000 8.000 3.990 215 1E12N057 4/25/08 AF 3.990 8.000 12.000 16.000 20.000 16.010 12.010 8.010 4.000 216 1E12N057 4/25/08 AL 3.990 8.000 12.000 16.000 20.000 16.010 12.010 8.010 4.000 217 1E12N057 7/19/06 AF 4.000 8.000 11.990 15.990 19.990 16.000 11.990 8.000 4.000 218 1E12N057 7/19/06 AL 4.000 8.000 11.990 15.990 19.990 16.000 11.990 8.000 4.000 219 1E12N057 1120/05 AF 4.000 8.000 12.000 16.000 20.000 16.010 12.020 8.010 4.000 220 1E12N057 1120/05 AL 4.000 8.000 12.000 16.000 20.000 16.010 12.020 8.010 4.000 221 1E12N057 8/8/03 AF 4.000 7.980 11.980 15.980 19.990 16.000 12.000 7.990 3.990 222 1E12N057 8/8/03 AL 4.000 7.980 11.980 15.980 19.990 16.000 12.000 7.990 3.990 223 1E12N057 2/20/02 AF 4.000 7.990 12.000 15.990 20.000 15.990 12.020 8.000 4.000 224 1E12N057 2/20/02 AL 4.000 7.990 12.000 15.990 20.000 15.990 12.020 8.000 4.000 225 1E12N057 2/8/01 AF 3.970 7.960 11.960 15.950 19.940 15.970 11.960 7.970 3.970 226 1E12N057 2/8/01 AL 4.000 7.990 11.990 15.990 19.990 16.000 12.000 8.000 4.000 227 1E12N057 8/1/99 AF 3.990 7.990 11.980 15.990 19.980 16.000 12.010 8.000 4.000 228 1E12N057 8/1/99 AL 3.990 7.990 11.980 15.990 19.980 16.000 12.010 8.000 4.000 229 1E12N057 1/27/98 AF 4.025 8.070 12.090 16.090 20.071 16.075 12.093 8.091 4.055 230 1E12N057 1/27/98 AL 4.014 8.004 12.013 16.016 20.002 16.020 12.023 8.008 3.998 231 1E12N058A 7/12/10 AF 3.990 7.980 11.980 15.990 19.990 16.000 11.990 7.990 3.990 232 1E12N058A 7/12/10 AL 3.990 7.980 11.980 15.990 19.990 16.000 11.990 7.990 3.990 233 1E12N058A 9/10/08 AF 4.000 8.000 12.000 16.000 20.000 16.000 12.020 8.010 4.000 234 1E12N058A 9/10/08 AL 4.000 8.000 12.000 16.000 20.000 16.000 12.020 8.010 4.000

DRIFT ANALYSIS ENGINEERING DEPARTMENT GRAND GULF NUCLEAR STATION Rosemount Range Codes 5 - 8 Gage Pressure Transmitters Data Conversion JC-Q1111-09019 Rev. 0 Page 68 of 134 IDENTIFYING INFORMATION ACTUAL AF/AL RAW VALUES 1

2 3

4 5

6 7

8 9

Seq. 10 Tag 10 Date AF/AL (0% Up)

(25% Up)

(50% Up)

(75% Up)

(100% Up)

(75% On)

(50% On)

(25% On)

(0% On) 235 1E12N058A 1/16/07 AF 3.990 8.000 11.990 16.000 20.000 16.000 12.000 8.010 3.990 236 1E12N058A 1/16/07 AL 3.990 8.000 11.990 16.000 20.000 16.000 12.000 8.010 3.990 237 1E12N058A 7/22/05 AF 3.990 8.000 12.000 16.000 20.000 15.990 12.000 7.990 4.000 238 1E12N058A 7/22/05 AL 3.990 8.000 12.000 16.000 20.000 15.990 12.000 7.990 4.000 239 1E12N058A 1/9/04 AF 4.010 7.990 11.970 15.960 19.940 15.970 11.980 7.990 4.010 240 1E12N058A 1/9/04 AL 4.000 8.000 12.000 15.990 20.000 15.990 12.000 8.000 4.000 241 1E12N058A 9/9/02 AF 4.020 8.040 12.030 16.030 EXC 16.030 12.030 8.040 4.020 242 1E12N058A 9/9/02 AL 4.010 8.010 12.000 16.010 20.000 16.010 11.990 8.020 4.010 243 1E12N058A 1/23/01 AF 4.030 8.020 12.020 16.020 20.030 16.020 12.030 8.030 4.030 244 1E12N058A 1/23/01 AL 4.030 8.020 12.020 16.020 20.030 16.020 12.030 8.030 4.030 245 1E12N058A 9/22/99 AF 3.930 7.970 11.970 15.970 19.960 15.970 11.980 7.970 3.950 246 1E12N058A 9/22/99 AL 4.010 8.020 12.010 16.020 20.000 16.010 12.020 8.020 4.010 247 1E12N058A 1/28/98 AF 3.980 7.980 11.980 16.000 20.000 15.990 12.000 7.990 4.000 248 1E12N058A 1/28/98 AL 3.980 7.980 11.980 16.000 20.000 15.990 12.000 7.990 4.000 249 1E12N058B 2/19/10 AF 4.000 7.970 11.960 15.970 19.990 15.980 11.970 7.960 4.000 250 1E12N058B 2119/10 AL 4.000 7.970 11.960 15.970 19.990 15.980 11.970 7.960 4.000 251 1E12N058B 7/10/08 AF 4.010 8.020 12.010 16.010 20.020 16.020 12.030 8.040 4.050 252 1E12N058B 7/10108 AL 4.000 7.990 11.990 15.990 20.000 16.000 12.000 8.000 4.000 253 1E12N058B 1110/07 AF 4.030 8.020 12.020 16.010 20.010 16.020 12.020 8.020 4.030 254 1E12N058B 1/10/07 AL 4.030 8.020 12.020 16.010 20.010 16.020 12.020 8.020 4.030 255 1E12N058B 6/29/05 AF 4.030 8.000 11.990 15.990 19.990 16.000 12.000 8.010 4.030 256 1E12N058B 6/29/05 AL 4.030 8.000 11.990 15.990 19.990 16.000 12.000 8.010 4.030 257 1E12N058B 1/14/04 AF 4.010 8.000 12.000 16.000 20.000 16.020 12.030 8.030 4.030 258 1E12N058B 1/14/04 AL 4.010 8.000 12.000 16.000 20.000 16.020 12.030 8.030 4.030 259 1E12N058B 7/18/02 AF 4.000 7.990 11.990 16.000 19.990 15.990 12.010 8.010 4.010 260 1E12N058B 7/18102 AL 4.000 7.990 11.990 16.000 19.990 15.990 12.010 8.010 4.010 261 1E12N058B 1/29/01 AF 4.030 8.000 11.980 15.980 20.020 16.000 11.990 8.010 4.030 262 1E12N058B 1/29/01 AL 4.030 8.000 11.980 15.980 20.020 16.000 11.990 8.010 4.030 263 1E12N058B 8/19/99 AF 4.034 8.028 12.026 16.017 20.016 16.018 12.024 8.026 4.030 264 1E12N058B 8/19/99 AL 4.034 8.028 12.026 16.017 20.016 16.018 12.024 8.026 4.030 265 1E12N058B 1/5/98 AF 3.990 8.020 12.020 16.070 20.060 16.080 12.060 8.020 4.030 266 1E12N058B 1/5/98 AL 4.000 8.000 12.000 16.000 19.990 16.010 12.010 8.010 4.010 267 1E12N058C 2116/10 AF 3.960 7.960 11.950 15.960 19.950 15.960 11.970 7.970 3.970 268 1E12N058C 2/16/10 AL 4.020 8.020 12.010 16.000 20.000 16.010 12.020 8.020 4.020 269 1E12N058C 6/24/08 AF 4.000 7.980 11.970 15.960 19.960 15.970 11.970 7.980 4.000 270 1E12N058C 6/24/08 AL 4.000 7.990 11.980 15.980 19.990 15.980 11.990 8.010 4.000 271 1E12N058C 12/2/06 AF 4.030 8.000 11.990 16.000 20.000 16.000 12.010 8.020 4.040 272 1E12N058C 12/2/06 AL 4.030 8.000 11.990 16.000 20.000 16.000 12.010 8.020 4.040 273 1E12N058C 5119/05 AF 4.020 8.000 11.980 15.980 19.990 16.000 12.010 8.010 4.020 274 1E12N058C 5/19/05 AL 4.020 8.000 11.980 15.980 19.990 16.000 12.010 8.010 4.020 275 1E12N058C 10/23/03 AF 4.010 7.990 11.980 15.970 19.980 16.000 12.000 8.010 4.020 276 1E12N058C 10/23/03 AL 4.010 7.990 11.980 15.970 19.980 16.000 12.000 8.010 4.020 277 1E12N058C 7/18/02 AF 3.960 7.960 11.960 15.960 19.960 15.960 11.960 7.960 3.970 278 1E12N058C 7/18/02 AL 4.010 8.000 11.990 15.990 19.990 15.990 11.990 7.990 4.000 279 1E12N058C 1/29/01 AF 3.980 7.980 11.970 15.990 20.020 16.000 12.010 8.000 3.990 280 1E12N058C 1/29/01 AL 3.980 7.980 11.970 15.990 20.020 16.000 12.010 8.000 3.990 281 1E12N058C 9/2/99 AF 4.040 8.060 12.080 16.100 20.100 16.080 12.120 8.050 4.020

DRIFT ANALYSIS ENGINEERING DEPARTMENT GRAND GULF NUCLEAR STATION Rosemount Range Codes 5 - 8 Gage Pressure Transmitters Data Conversion JC-Q1111-09019 Rev. 0 Page 69 of 134 IDENTIFYING INFORMATION ACTUAL AF/AL RAW VALUES Seq. 10 Tag 10 Date 1

2 3

4 5

6 7

8 9

AF/AL (0% Up)

(25% Up)

(50% Up)

(75% Up)

(100% Up)

(75% On)

(50% On)

(25% On)

(0% On) 282 1E12N058C 9/2/99 AL 3.980 8.010 12.010 16.010 20.030 16.020 12.030 8.010 3.990 283 1E12N058C 2/21/98 AF 3.970 7.990 11.920 15.930 19.940 15.960 11.940 7.980 3.970 284 1E12N058C 2/21/98 AL 4.010 7.980 11.980 16.000 20.000 16.000 11.980 7.980 4.010 285 1E21N05O 8/27/10 AF 3.990 7.990 11.980 15.990 19.990 15.990 11.990 8.000 3.990 286 1E21N05O 8/27/10 AL 3.990 7.990 11.980 15.990 19.990 15.990 11.990 8.000 3.990 287 1E21N05O 11/20/08 AF 3.990 7.980 11.980 15.990 19.980 15.990 12.000 8.010 4.010 288 1E21N05O 11/20/08 AL 3.990 7.980 11.980 15.990 19.980 15.990 12.000 8.010 4.010 289 1E21N05O 5/11/07 AF 3.980 7.970 11.970 15.970 19.980 15.980 12.000 7.980 3.990 290 1E21N05O 5/11/07 AL 3.980 7.970 11.970 15.970 19.980 15.980 12.000 7.980 3.990 291 1E21N05O 7118/05 AF 3.990 7.980 11.990 16.000 20.000 16.000 11.990 7.990 4.010 292 1E21N05O 7118/05 AL 3.990 7.980 11.990 16.000 20.000 16.000 11.990 7.990 4.010 293 1E21N05O 10/14/03 AF 3.990 7.990 11.980 15.990 19.990 16.000 12.000 7.990 4.000 294 1E21N05O 10/14/03 AL 3.990 7.990 11.980 15.990 19.990 16.000 12.000 7.990 4.000 295 1E21N05O 4/18/02 AF 3.970 7.950 11.950 15.960 19.970 15.980 11.960 7.970 3.960 296 1E21N05O 4/18/02 AL 4.000 8.000 11.980 15.990 20.020 16.000 11.990 7.990 4.000 297 1E21N05O 10/16/00 AF 3.990 7.990 11.980 15.980 20.000 15.990 11.990 7.990 4.000 298 1E21N05O 10/16/00 AL 3.990 7.990 11.980 15.980 20.000 15.990 11.990 7.990 4.000 299 1E21N05O 4/11/99 AF 3.977 7.966 11.975 15.989 20.004 16.003 11.993 7.987 4.000 300 1E21N05O 4/11/99 AL 3.977 7.966 11.975 15.989 20.004 16.003 11.993 7.987 4.000 301 1E21N05O 8/30/97 AF 3.990 8.000 12.000 15.980 19.990 16.000 12.000 8.000 4.000 302 1E21N05O 8/30/97 AL 3.990 8.000 12.000 15.980 19.990 16.000 12.000 8.000 4.000 303 1E21N052 2/8/10 AF 4.040 8.000 12.010 16.000 20.000 16.010 12.010 8.000 4.040 304 1E21N052 218/10 AL 4.040 8.000 12.010 16.000 20.000 16.010 12.010 8.000 4.040 305 1E21N052 5/22/08 AF 3.990 7.920 11.920 15.900 19.900 15.900 11.910 7.910 3.990 306 1E21N052 5/22/08 AL 4.060 8.000 11.990 15.990 19.990 15.990 11.990 8.000 4.060 307 1E21N052 11/10/06 AF 4.050 8.000 11.980 15.980 19.980 15.980 11.980 7.990 4.050 308 1E21N052 11/10/06 AL 4.050 8.000 11.980 15.980 19.980 15.980 11.980 7.990 4.050 309 1E21N052 4/12/05 AF 3.940 7.930 11.930 15.940 19.940 15.930 11.930 7.930 3.960 310 1E21N052 4/12/05 AL 4.040 7.990 12.000 16.000 19.990 16.000 11.990 8.000 4.040 311 1E21N052 6/25/03 AF 4.090 8.120 12.120 16.230 20.310 16.230 12.120 8.120 4.100 312 1E21N052 6/25/03 AL 4.010 7.980 11.980 15.990 19.990 15.990 11.980 7.980 4.010 313 1E21N052 1/9/02 AF 4.070 7.990 11.910 15.850 19.760 15.830 11.900 7.980 4.090 314 1E21 N052 1/9/02 AL 4.070 8.010 12.000 16.010 20.010 16.010 12.010 8.020 4.070 315 1E21N052 9/10/00 AF 4.000 7.940 11.930 15.930 19.930 15.940 11.940 7.940 4.000 316 1E21N052 9/10/00 AL 4.050 7.980 11.980 15.980 19.980 15.980 11.990 7.980 4.050 317 1E21N052 3/10/99 AF 4.050 7.990 11.980 15.980 19.990 15.990 11.990 7.980 4.060 318 1E21N052 3/10/99 AL 4.050 7.990 11.980 15.980 19.990 15.990 11.990 7.980 4.060 319 1E21N052 8/25/97 AF 4.041 8.023 12.017 16.014 20.007 16.009 12.020 8.019 4.052 320 1E21N052 8/25/97 AL 4.041 8.023 12.017 16.014 20.007 16.009 12.020 8.019 4.052 321 1E21N053 8/10/09 AF 4.030 7.990 11.990 15.990 19.990 16.000 12.000 7.990 4.040 322 1E21N053 8/10/09 AL 4.030 7.990 11.990 15.990 19.990 16.000 12.000 7.990 4.040 323 1E21N053 2/14/08 AF 4.050 7.990 12.000 16.000 20.000 16.000 12.010 8.000 4.050 324 1E21N053 2/14/08 AL 4.050 7.990 12.000 16.000 20.000 16.000 12.010 8.000 4.050 325 1E21N053 8/15/06 AF 4.030 8.000 12.000 16.020 19.990 16.020 12.000 8.000 4.030 326 1E21N053 8/15/06 AL 4.030 8.000 12.000 16.020 19.990 16.020 12.000 8.000 4.030 327 1E21N053 1/22/05 AF 4.020 7.980 12.000 15.990 20.020 15.990 12.000 7.990 4.020 328 1E21N053 1/22/05 AL 4.020 7.980 12.000 15.990 20.020 15.990 12.000 7.990 4.020

DRIFT ANALYSIS ENGINEERING DEPARTMENT GRAND GULF NUCLEAR STATION Rosemount Range Codes 5 - 8 Gage Pressure Transmitters Data Conversion JC-Q1111-09019 Rev. 0 Page 70 of 134 IDENTIFYING INFORMATION ACTUAL AFIAL RAW VALUES Seq. 10 Tag 10 Date AFIAL 1

2 3

4 5

6 7

8 9

(0% Up)

(25% Up)

(50% Up)

(75% Up)

(100% Up)

(75% On)

(50% On)

(25% On)

(0% On) 329 1E21N053 7/22103 AF 4.020 8.040 12.100 16.160 20.210 16.170 12.100 8.040 4.030 330 1E21N053 7/22/03 AL 4.040 8.000 12.000 16.010 20.000 16.010 12.010 8.000 4.040 331 1E21 N053 1/10/02 AF 4.020 8.030 12.040 16.020 20.010 16.030 12.040 8.040 4.030 332 1E21N053 1/10/02 AL 4.020 8.030 12.040 16.020 20.010 16.030 12.040 8.040 4.030 333 1E21N053 9/10/00 AF 3.980 7.900 11.900 15.880 19.870 15.900 11.890 7.900 3.980 334 1E21N053 9/10/00 AL 4.070 8.010 12.000 16.000 19.970 16.000 12.000 8.010 4.070 335 1E21 N053 3/11/99 AF 4.047 8.000 12.000 16.010 20.010 16.020 12.010 8.000 4.039 336 1E21N053 3/11/99 AL 4.047 8.000 12.000 16.010 20.010 16.020 12.010 8.000 4.039 337 1E21N053 8/25/97 AF 4.034 8.018 12.014 16.002 20.008 15.994 12.010 7.999 4.038 338 1E21N053 8/25/97 AL 4.034 8.018 12.014 16.002 20.008 15.994 12.010 7.999 4.038 339 1E21N054 9/24/10 AF 4.010 7.980 11.980 15.980 19.990 15.990 12.000 8.000 4.020 340 1E21N054 9/24/10 AL 4.010 7.980 11.980 15.980 19.990 15.990 12.000 8.000 4.020 341 1E21N054 11/20/08 AF 4.180 8.070 12.040 16.040 19.970 16.040 12.070 8.090 4.180 342 1E21N054 11/20/08 AL 4.030 7.970 11.970 15.990 20.030 16.030 12.000 7.980 4.030 343 1E21N054 5/7/07 AF 4.020 7.990 11.980 15.980 19.970 16.000 12.010 8.010 4.020 344 1E21N054 5/7/07 AL 4.020 7.990 11.980 15.980 19.970 16.000 12.010 8.010 4.020 345 1E21N054 811105 AF 4.020 7.990 11.980 15.980 19.980 16.000 12.010 8.010 4.030 346 1E21N054 8/1/05 AL 4.020 7.990 11.980 15.980 19.980 16.000 12.010 8.010 4.030 347 1E21N054 12/9/03 AF 4.020 7.970 11.990 16.010 19.990 15.990 12.000 7.990 4.030 348 1E21N054 12/9/03 AL 4.020 7.970 11.990 16.010 19.990 15.990 12.000 7.990 4.030 349 1E21N054 7/11/02 AF 4.030 8.000 12.000 16.000 20.010 16.000 11.990 7.990 4.030 350 1E21N054 7/11/02 AL 4.030 8.000 12.000 16.000 20.010 16.000 11.990 7.990 4.030 351 1E21N054 1/23/01 AF 4.020 7.990 11.990 15.990 19.990 15.990 12.000 8.000 4.020 352 1E21N054 1/23/01 AL 4.020 7.990 11.990 15.990 19.990 15.990 12.000 8.000 4.020 353 1E21N054 7/12/99 AF 4.034 8.000 11.997 15.982 19.983 16.000 12.014 8.011 4.035 354 1E21N054 7/12/99 AL 4.034 8.000 11.997 15.982 19.983 16.000 12.014 8.011 4.035 355 1E21N054 1/15/98 AF 4.020 8.000 11.980 16.000 20.010 16.020 12.010 8.010 4.020 356 1E21N054 1/15/98 AL 4.020 8.000 11.980 16.000 20.010 16.020 12.010 8.010 4.020 357 1E22N05O 3/19/10 AF 5.850 8.080 11.910 16.070 19.910 16.070 11.910 8.070 5.840 358 1E22N05O 3/19/10 AL 5.880 8.120 11.960 16.120 19.960 16.120 11.960 8.120 5.880 359 1E22N05O 6/27/08 AF EXC 8.100 11.940 16.110 19.950 16.110 11.950 8.100 EXC 360 1E22N05O 6/27/08 AL EXC 8.100 11.940 16.110 19.950 16.110 11.950 8.100 EXC 361 1E22N05O 11/15/06 AF EXC 8.110 11.930 16.080 19.900 16.080 11.930 8.110 EXC 362 1E22N05O 11/15/06 AL EXC 8.120 11.960 16.120 19.960 16.120 11.960 8.120 EXC 363 1E22N05O 6/3/05 AF EXC 7.860 11.860 15.960 19.860 15.990 11.720 7.920 EXC 364 1E22N050 6/3/05 AL EXC 8.120 11.940 16.100 19.950 16.110 11.950 8.140 EXC 365 1E22N05O 9/26/03 AF EXC 7.960 11.830 16.000 19.830 16.000 11.840 7.980 EXC 366 1E22N05O 9/26/03 AL EXC 8.110 11.930 16.120 19.970 16.140 11.960 8.100 EXC 367 1E22N05O 4/12/02 AF EXC 8.090 11.930 16.080 19.930 16.090 11.940 8.100 EXC 368 1E22N05O 4/12/02 AL EXC 8.090 11.930 16.080 19.930 16.090 11.940 8.100 EXC 369 1E22N05O 11/24/00 AF EXC 8.210 12.010 16.150 19.970 16.130 11.960 8.140 EXC 370 1E22N05O 11/24/00 AL EXC 8.160 11.980 16.120 19.950 16.120 11.930 8.150 EXC 371 1E22N05O 4/2/99 AF EXC 8.110 11.950 16.110 19.930 16.110 11.950 8.110 EXC 372 1E22N050 4/2/99 AL EXC 8.110 11.950 16.110 19.930 16.110 11.950 8.110 EXC 373 1E22N05O 9/5/97 AF EXC 8.086 11.980 16.135 19.982 16.096 11.952 8.134 EXC 374 1E22N050 9/5/97 AL EXC 8.086 11.980 16.135 19.982 16.096 11.952 8.134 EXC

DRIFT ANALYSIS ENGINEERING DEPARTMENT GRAND GULF NUCLEAR STATION Rosemount Range Codes 5 - 8 Gage Pressure Transmitters Data Conversion JC-Q1111-09019 Rev. 0 Page 71 of 134 IDENTIFYING INFORMATION ACTUAL AF/AL RAW VALUES Seq. 10 Tag 10 Date AF/AL 1

2 3

4 5

6 7

8 9

(0% Up)

(25% Up)

(50% Up)

(75% Up)

(100% Up)

(75% On)

(50% On)

(25% On)

(0% On) 375 1E22N054C 4/2/10 AF 4.070 7.950 11.980 15.990 19.990 15.990 11.980 7.950 4.070 376 1E22N054C 4/2/10 AL 4.060 7.930 11.940 15.960 19.970 15.960 11.940 7.930 4.060 377 1E22N054C 5/30/08 AF 4.090 7.950 11.970 15.990 20.010 15.990 11.970 7.950 4.090 378 1E22N054C 5/30/08 AL 4.060 7.930 11.950 15.970 19.970 15.970 11.960 7.930 4.060 379 1E22N054C 1/12/07 AF EXC EXC EXC EXC EXC EXC EXC EXC EXC 380 1E22N054C 1/12107 AL 4.070 7.920 11.950 15.970 19.980 15.970 11.950 7.930 4.070 381 1E22N054G 11/20/09 AF 4.060 7.920 11.940 15.970 19.990 15.980 11.960 7.930 4.070 382 1E22N054G 11/20/09 AL 4.060 7.920 11.940 15.970 19.990 15.980 11.960 7.930 4.070 383 1E22N054G 5/30/08 AF 4.060 7.900 11.920 15.940 19.960 15.940 11.920 7.910 4.060 384 1E22N054G 5/30/08 AL 4.050 7.910 11.940 15.960 19.970 15.950 11.940 7.910 4.050 385 1E22N054G 10/20/06 AF EXC EXC EXC EXC EXC EXC EXC EXC EXC 386 1E22N054G 10/20/06 AL 4.060 7.900 11.920 15.940 19.970 15.940 11.920 7.900 4.060 387 1E31N085A 5/12/10 AF 4.020 7.990 11.980 15.980 20.000 15.990 11.980 7.990 4.020 388 1E31 N085A 5/12/10 AL 4.020 7.990 11.980 15.980 20.000 15.990 11.980 7.990 4.020 389 1E31 N085A 9/30/08 AF 3.970 7.960 11.940 15.950 19.970 15.950 11.940 7.960 3.970 390 1E31 N085A 9/30/08 AL 4.000 7.980 11.980 15.980 20.000 15.980 11.980 7.990 4.000 391 1E31N085A 4/2/07 AF 3.990 7.990 11.970 15.970 20.000 15.980 11.980 7.990 4.010 392 1E31N085A 4/2107 AL 3.990 7.990 11.970 15.970 20.000 15.980 11.980 7.990 4.010 393 1E31N085A 9/28/05 AF 4.000 7.960 11.940 15.930 19.940 15.930 11.940 7.970 4.010 394 1E31N085A 9/28/05 AL 4.010 7.980 11.980 15.970 20.000 15.980 11.980 7.980 4.010 395 1E31 N085A 3/5/04 AF 3.960 7.980 11.980 15.980 20.020 15.980 11.980 7.980 3.970 396 1E31N085A 3/5/04 AL 3.990 7.980 11.980 15.970 20.020 15.970 11.970 7.970 3.990 397 1E31 N085A 9/23/02 AF 3.980 7.990 11.980 16.000 20.040 16.000 11.990 7.990 4.030 398 1E31N085A 9/23/02 AL 3.980 7.990 11.980 16.000 20.040 16.000 11.990 7.990 4.030 399 1E31N085A 4/24/01 AF 4.130 8.140 12.140 16.160 20.160 16.170 12.150 8.150 4.130 400 1E31N085A 4/24/01 AL 4.000 8.010 12.010 16.020 20.020 16.020 12.020 8.010 4.010 401 1E31N085A 11/4/99 AF 3.790 7.750 11.720 15.710 19.720 15.720 11.710 7.750 3.780 402 1E31 N085A 11/4/99 AL 4.010 7.980 11.980 15.980 20.010 15.980 11.980 7.990 4.010 403 1E31 N085A 4/24/98 AF 4.010 8.000 11.970 15.982 20.000 15.981 11.973 7.988 3.971 404 1E31N085A 4/24/98 AL 4.010 8.000 11.970 15.982 20.000 15.981 11.973 7.988 3.971 405 1E31N085B 5/4/10 AF 3.950 7.900 11.880 15.880 19.930 15.890 11.880 7.910 3.950 406 1E31N085B 5/4/10 AL 4.020 7.980 11.970 15.980 20.030 15.980 11.970 7.980 4.020 407 1E31N085B 9/30/08 AF 4.000 7.970 11.970 15.980 20.010 15.980 11.980 8.000 4.010 408 1E31N085B 9/30/08 AL 4.000 7.970 11.970 15.980 20.010 15.980 11.980 8.000 4.010 409 1E31N085B 4/1/07 AF 4.070 8.070 12.080 16.080 20.110 16.050 12.050 8.060 4.070 410 1E31N085B 4/1/07 AL 4.020 7.990 11.980 15.980 20.020 15.980 11.980 7.990 4.020 411 1E31N085B 9/27/05 AF 4.020 7.970 11.930 15.910 19.940 15.920 11.930 7.970 4.030 412 1E31N085B 9/27/05 AL 4.030 7.980 11.980 15.980 20.020 15.980 11.980 7.980 4.030 413 1E31 N085B 3/4/04 AF 5.500 9.800 13.750 17.670 21.570 17.750 13.750 9.750 6.000 414 1E31 N085B 3/4/04 AL 4.030 8.030 11.970 15.970 20.020 15.970 11.970 8.000 4.020 415 1E31N085B 9/23/02 AF 3.980 8.010 12.050 16.100 20.200 16.180 12.080 8.020 3.990 416 1E31N085B 9/23/02 AL 4.010 7.980 11.970 15.980 20.010 15.980 11.980 7.990 4.010 417 1E31N085B 4/19/01 AF 4.120 8.060 11.990 15.940 19.910 15.940 11.990 8.060 4.120 418 1E31 N085B 4/19/01 AL 4.010 7.990 11.980 15.990 20.000 15.990 11.980 7.990 4.010 419 1E31N085B 11/17/99 AF 3.930 7.880 11.830 15.830 19.830 15.830 11.840 7.880 3.930

DRIFT ANALYSIS ENGINEERING DEPARTMENT GRAND GULF NUCLEAR STATION Rosemount Range Codes 5 - 8 Gage Pressure Transmitters Data Conversion JC-Q1111-09019 Rev. 0 Page 72 of 134 IDENTIFYING INFORMATION ACTUAL AF/AL RAW VALUES Seq. 10 Tag 10 Date AF/AL 1

2 3

4 5

6 7

8 9

(0% Up)

(25% Up)

(50% Up)

(75% Up)

(100% Up)

(75% On)

(50% On)

(25% On)

(0% On) 420 1E31N0858 11/17/99 AL 4.020 8.000 11.990 16.000 20.020 16.000 11.990 8.000 4.020 421 1E31N0858 4/24/98 AF 4.039 7.987 12.001 15.991 20.002 15.980 11.985 8.001 4.007 422 1E31N0858 4/24/98 AL 4.039 7.987 12.001 15.991 20.002 15.980 11.985 8.001 4.007 423 1E32NOSO 5/4/10 AF 4.000 8.000 11.990 15.980 20.000 15.990 12.000 8.000 4.000 424 1E32NOSO 5/4/10 AL 4.000 8.000 11.990 15.980 20.000 15.990 12.000 8.000 4.000 425 1E32NOSO 10/4/08 AF 4.030 8.040 12.030 16.030 20.040 16.030 12.040 8.040 4.030 426 1E32NOSO 10/4/08 AL 4.000 8.000 12.000 15.990 20.000 15.990 12.000 8.000 4.000 427 1E32NOSO 4/4/07 AF 4.040 8.020 12.010 16.010 20.010 16.010 12.010 8.020 4.040 428 1E32NOSO 4/4/07 AL 4.040 8.020 12.010 16.010 20.010 16.010 12.010 8.020 4.040 429 1E32NOSO 9/29/05 AF 3.980 8.010 11.990 16.000 19.990 15.980 11.980 7.980 4.000 430 1E32N050 9/29/05 AL 3.980 8.010 11.990 16.000 19.990 15.980 11.980 7.980 4.000 431 1E32NOSO 317104 AF EXC EXC EXC EXC EXC EXC EXC EXC EXC 432 1E32NOSO 317104 AL 4.040 8.030 12.020 16.010 20.020 16.010 12.030 8.040 4.040 433 1E32NOSO 9/28/02 AF 4.000 8.030 12.010 16.010 20.010 16.010 12.020 8.030 4.010 434 1E32NOSO 9/28/02 AL 4.000 8.030 12.010 16.010 20.010 16.010 12.020 8.030 4.010 435 1E32NOSO 5/3/01 AF 3.630 7.640 11.630 15.630 19.640 15.640 11.660 7.650 3.610 436 1E32NOSO 5/3/01 AL 4.000 8.010 12.000 16.000 20.000 16.000 12.010 7.990 3.990 437 1E32NOSO 11/6/99 AF 4.230 8.130 11.990 15.870 19.750 15.860 12.000 8.120 4.240 438 1E32NOSO 11/6/99 AL 4.010 8.000 11.990 15.990 19.980 15.990 11.990 8.000 4.010 439 1E32NOSO 5/31/99 AF 3.981 8.139 12.240 16.400 20.547 16.400 12.240 8.139 3.981 440 1E32NOSO 5/31/99 AL 4.010 7.980 11.960 15.980 20.000 15.980 11.970 7.990 4.010 441 1E32NOSO 10/6/97 AF 3.970 7.970 11.990 15.970 19.980 15.970 12.010 7.980 4.000 442 1E32NOSO 10/6/97 AL 3.970 7.970 11.990 15.970 19.980 15.970 12.010 7.980 4.000 443 1E32N055 7/8/09 AF 4.000 7.990 11.990 16.000 20.020 16.000 12.010 8.000 4.000 444 1E32N055 7/8/09 AL 4.000 7.990 11.990 16.000 20.020 16.000 12.010 8.000 4.000 445 1E32N055 117108 AF 3.990 8.000 12.000 16.010 20.040 16.010 12.010 8.010 4.000 446 1E32N055 1/7/08 AL 3.990 8.000 12.000 16.010 20.040 16.010 12.010 8.010 4.000 447 1E32N055 4/5/06 AF 4.000 7.980 11.980 15.970 20.000 15.980 11.980 7.990 4.000 448 1E32N055 4/5/06 AL 4.000 7.980 11.980 15.970 20.000 15.980 11.980 7.990 4.000 449 1E32N055 10/6/04 AF 4.010 7.970 11.930 15.940 19.990 15.940 11.950 7.970 4.020 450 1E32N055 10/6/04 AL 4.000 7.980 11.960 15.970 20.000 15.980 11.980 7.980 3.990 451 1E32N055 4/22/03 AF 4.040 8.020 12.000 16.000 20.030 16.000 12.010 8.020 4.040 452 1E32N055 4/22/03 AL 4.030 8.000 11.970 15.970 20.020 15.980 11.970 8.000 4.030 453 1E32N055 11/19/01 AF 4.050 7.990 11.980 15.940 19.950 15.930 11.960 7.970 4.040 454 1E32N055 11/19/01 AL 4.000 7.990 11.990 15.970 19.990 15.960 12.000 8.000 4.000 455 1E32N055 8/17/00 AF 4.010 7.960 11.930 15.930 19.960 15.940 11.960 7.980 3.990 456 1E32N055 8/17/00 AL 4.000 8.000 11.970 15.970 20.010 15.970 11.980 7.990 4.010 457 1E32N055 2/16/99 AF 4.010 7.990 11.990 15.990 19.990 15.970 12.000 8.010 3.980 458 1E32N055 2/16/99 AL 4.010 7.990 11.990 15.990 19.990 15.970 12.000 8.010 3.980 459 1E32N055 8/19/97 AF 3.990 8.000 11.980 15.980 19.990 15.980 11.980 8.020 4.000 460 1E32N055 8/19/97 AL 3.990 8.000 11.980 15.980 19.990 15.980 11.980 8.020 4.000 461 1E32N058 4/30/10 AF 3.990 8.010 12.000 15.990 19.990 15.990 12.010 8.010 3.990 462 1E32N058 4/30/10 AL 3.990 8.010 12.000 15.990 19.990 15.990 12.010 8.010 3.990 463 1E32N058 10/2/08 AF 4.000 8.020 12.020 16.020 20.030 16.020 12.030 8.020 4.000 464 1E32N058 10/2/08 AL 4.000 8.020 12.020 16.020 20.030 16.020 12.030 8.020 4.000 465 1E32N058 3/25/07 AF 3.990 8.020 12.020 16.020 20.030 16.020 12.020 8.020 3.990 466 1E32N058 3/25/07 AL 3.990 8.020 12.020 16.020 20.030 16.020 12.020 8.020 3.990

DRIFT ANALYSIS ENGINEERING DEPARTMENT GRAND GULF NUCLEAR STATION Rosemount Range Codes 5 - 8 Gage Pressure Transmitters Data Conversion JC-Q1111-09019 Rev. 0 Page 73 of 134 IDENTIFYING INFORMATION ACTUAL AFIAL RAW VALUES Seq. 10 Tag 10 Date AF/AL 1

2 3

4 5

6 7

8 9

(0% Up)

(25% Up)

(50% Up)

(75% Up)

(100% Up)

(75% On)

(50% On)

(25% On)

(0% On) 467 1E32N058 9/22/05 AF 4.000 8.010 12.000 15.990 19.990 15.990 12.010 8.010 4.000 468 1E32N058 9/22/05 AL 4.000 8.010 12.000 15.990 19.990 15.990 12.010 8.010 4.000 469 1E32N058 3/5/04 AF EXC EXC EXC EXC EXC EXC EXC EXC EXC 470 1E32N058 3/5/04 AL 4.000 8.010 12.000 15.990 19.980 15.990 12.010 8.020 4.000 471 1E32N058 9/15/02 AF 3.900 7.940 11.950 15.920 19.930 15.920 11.930 7.940 3.900 472 1E32N058 9/15/02 AL 3.990 8.020 12.010 15.990 19.990 15.990 12.010 8.020 3.970 473 1E32N058 4/23/01 AF 2.750 6.180 9.970 13.740 17.600 13.740 9.990 6.180 2.750 474 1E32N058 4/23/01 AL 4.000 8.020 12.020 16.020 20.020 16.020 12.020 8.020 4.000 475 1E32N058 11/9/99 AF EXC EXC EXC EXC EXC EXC EXC EXC EXC 476 1E32N058 11/9/99 AL EXC EXC EXC EXC EXC EXC EXC EXC EXC 477 1E32N058 6/21/99 AF 4.150 8.320 12.430 16.550 20.700 16.550 12.430 8.320 4.140 478 1E32N058 6/21/99 AL 4.000 8.000 11.980 15.980 20.000 15.980 11.990 8.000 3.990 479 1E32N058 10/28/97 AF 3.970 7.980 12.000 16.010 20.040 16.030 12.020 8.000 3.960 480 1E32N058 10/28/97 AL 4.010 8.020 11.990 15.980 19.990 15.980 12.010 8.000 3.990 481 1E32N061A 8/12/09 AF 4.010 8.010 12.000 15.990 20.000 16.000 12.000 8.010 4.010 482 1E32N061A 8/12/09 AL 4.010 8.010 12.000 15.990 20.000 16.000 12.000 8.010 4.010 483 1E32N061A 2115/08 AF 4.000 8.000 12.000 15.990 20.000 15.990 12.000 8.000 4.000 484 1E32N061A 2/15/08 AL 4.000 8.000 12.000 15.990 20.000 15.990 12.000 8.000 4.000 485 1E32N061A 8/28/06 AF 4.010 8.010 12.000 15.990 20.000 16.000 12.000 8.010 4.010 486 1E32N061A 8/28/06 AL 4.010 8.010 12.000 15.990 20.000 16.000 12.000 8.010 4.010 487 1E32N061A 117105 AF EXC EXC EXC EXC EXC EXC EXC EXC EXC 488 1E32N061A 117105 AL 4.000 8.000 12.000 15.990 20.000 16.000 12.000 8.000 4.000 489 1E32N061A 5/13/03 AF 3.950 7.970 11.950 15.950 19.950 15.950 11.950 7.970 3.950 490 1E32N061A 5/13/03 AL 4.000 8.020 12.000 16.000 20.000 16.000 12.000 8.020 4.000 491 1E32N061A 11/26/01 AF 4.010 8.020 12.070 16.080 20.100 16.070 12.080 8.030 4.020 492 1E32N061A 11/26/01 AL 4.000 8.020 12.020 16.010 20.000 16.000 12.020 8.030 4.000 493 1E32N061A 10/2/00 AF 4.000 7.970 11.950 15.900 19.900 15.910 11.950 7.990 4.000 494 1E32N061A 10/2/00 AL 4.020 8.010 12.010 16.000 20.020 16.010 12.020 8.030 4.030 495 1E32N061A 4/9/99 AF 4.040 8.000 12.000 16.000 20.010 16.010 12.020 8.020 4.030 496 1E32N061A 4/9/99 AL 4.040 8.000 12.000 16.000 20.010 16.010 12.020 8.020 4.030 497 1E32N061A 10/8/97 AF 4.100 8.100 12.090 16.110 20.100 16.110 12.090 8.110 4.100 498 1E32N061A 10/8/97 AL 3.990 8.000 12.000 16.000 20.000 16.000 12.000 8.000 4.000 499 1E32N061E 11/2/09 AF 3.980 7.980 11.990 15.990 19.990 15.990 11.990 7.990 3.980 500 1E32N061E 11/2109 AL 3.980 7.980 11.990 15.990 19.990 15.990 11.990 7.990 3.980 501 1E32N061E 1/30/08 AF 3.990 7.990 11.990 15.990 19.990 15.990 11.990 7.990 3.990 502 1E32N061E 1130/08 AL 3.990 7.990 11.990 15.990 19.990 15.990 11.990 7.990 3.990 503 1E32N061E 4/14/06 AF 4.040 8.040 12.040 16.030 20.040 16.030 12.040 8.040 4.040 504 1E32N061E 4/14/06 AL 4.000 8.000 12.000 15.990 20.000 15.990 11.990 8.000 4.000 505 1E32N061E 10/28/04 AF EXC EXC EXC EXC EXC EXC EXC EXC EXC 506 1E32N061E 10/28/04 AL 4.030 8.020 12.020 16.010 20.000 16.010 12.020 8.020 4.030 507 1E32N061E 5/28/03 AF 3.930 7.930 11.920 15.910 19.910 15.910 11.920 7.930 3.930 508 1E32N061E 5/28/03 AL 3.990 7.990 11.990 15.990 19.990 15.990 11.990 7.990 3.990 509 1E32N061E 11/28/01 AF 3.960 7.970 11.960 15.930 19.900 15.920 11.960 7.970 3.960 510 1E32N061E 11/28/01 AL 4.000 8.010 12.010 16.000 19.990 15.990 12.000 8.010 4.000 511 1E32N061E 11/30/00 AF 4.020 8.040 12.060 16.070 20.060 16.060 12.070 8.040 4.030 512 1E32N061E 11/30/00 AL 4.010 8.020 12.030 16.010 19.980 16.000 12.030 8.020 4.010 513 1E32N061E 4/9/99 AF 3.970 7.960 11.940 15.940 19.950 15.950 11.940 7.950 3.950

DRIFT ANALYSIS ENGINEERING DEPARTMENT GRAND GULF NUCLEAR STATION Rosemount Range Codes 5 - 8 Gage Pressure Transmitters Data Conversion JC-Q1111-09019 Rev. 0 Page 74 of 134 IDENTIFYING INFORMATION ACTUAL AF/AL RAW VALUES Seq. 10 1

2 3

4 5

6 7

8 9

Tag 10 Date AF/AL (0% Up)

(25% Up)

(50% Up)

(75% Up)

(100% Up)

(75% On)

(50% On)

(25% On)

(0% On) 514 1E32N061E 4/9/99 AL 4.000 7.990 11.990 15.990 20.000 16.000 11.990 8.000 3.990 515 1E32N061E 10/8/97 AF 4.020 7.990 12.000 16.010 19.990 15.990 12.000 8.010 3.990 516 1E32N061E 10/8/97 AL 4.020 7.990 12.000 16.010 19.990 15.990 12.000 8.010 3.990 517 1E32N061J 5/5/09 AF 3.990 7.970 11.960 15.970 20.000 15.960 11.970 7.970 4.000 518 1E32N061J 5/5/09 AL 3.990 7.970 11.960 15.970 20.000 15.960 11.970 7.970 4.000 519 1E32N061J 11/9/07 AF 4.030 8.010 12.000 16.000 20.030 15.990 11.990 8.000 4.020 520 1E32N061J 11/9/07 AL 4.030 8.010 12.000 16.000 20.030 15.990 11.990 8.000 4.020 521 1E32N061J 5/11/06 AF 4.030 7.980 11.950 15.940 19.950 15.940 11.950 7.990 4.030 522 1E32N061J 5/11/06 AL 4.020 7.990 11.970 15.980 20.020 15.980 11.980 7.990 4.020 523 1E32N061J 9/29/04 AF EXC EXC EXC EXC EXC EXC EXC EXC EXC 524 1E32N061J 9/29/04 AL 4.040 8.000 11.960 15.960 19.980 15.970 11.980 8.000 4.040 525 1E32N061J 4/3/03 AF 3.980 7.980 11.980 15.980 20.010 15.990 11.980 7.980 3.980 526 1E32N061J 4/3/03 AL 4.000 7.980 11.960 15.960 20.000 15.970 11.970 7.980 4.000 527 1E32N061J 11/12101 AF 3.960 7.930 11.930 15.960 20.020 15.960 11.940 7.940 3.940 528 1E32N061J 11/12101 AL 4.000 7.980 11.980 15.980 20.000 15.980 11.980 7.980 4.000 529 1E32N061J 7/24/00 AF 4.130 8.090 12.090 16.100 20.120 16.090 12.090 8.110 4.150 530 1E32N061J 7/24/00 AL 3.980 7.960 11.970 15.980 20.000 15.980 11.960 7.970 3.990 531 1E32N061J 1/27/99 AF 4.030 8.010 12.000 16.010 20.030 16.010 12.000 8.010 4.030 532 1E32N061J 1/27/99 AL 4.030 8.010 12.000 16.010 20.030 16.010 12.000 8.010 4.030 533 1E32N061J 7/16/97 AF 3.890 7.870 11.850 15.810 19.820 15.780 11.800 7.860 3.900 534 1E32N061J 7/16/97 AL 4.020 8.010 11.990 15.990 20.000 15.980 11.970 7.990 4.020 535 1E32N061N 12/8/09 AF 4.010 8.000 12.000 16.000 20.000 16.000 12.000 8.010 4.010 536 1E32N061N 12/8/09 AL 4.010 8.000 12.000 16.000 20.000 16.000 12.000 8.010 4.010 537 1E32N061N 6/16/08 AF 4.010 8.010 12.000 15.990 20.010 16.000 12.000 8.010 4.010 538 1E32N061N 6/16/08 AL 4.010 8.010 12.000 15.990 20.010 16.000 12.000 8.010 4.010 539 1E32N061N 8/28/06 AF 4.010 8.010 12.000 16.000 20.010 16.000 12.010 8.010 4.010 540 1E32N061N 8/28/06 AL 4.010 8.010 12.000 16.000 20.010 16.000 12.010 8.010 4.010 541 1E32N061N 1/7/05 AF EXC EXC EXC EXC EXC EXC EXC EXC EXC 542 1E32N061N 1/7/05 AL 4.010 8.010 12.000 16.000 20.010 16.000 12.010 8.000 4.010 543 1E32N061N 5/16/03 AF 3.920 7.920 11.920 15.930 19.960 15.940 11.930 7.930 3.920 544 1E32N061N 5/16/03 AL 4.010 8.010 12.020 16.010 20.020 16.020 12.020 8.010 4.010 545 1E32N061N 11/12/01 AF 3.960 7.960 11.970 15.970 19.990 15.970 11.970 7.970 3.960 546 1E32N061N 11/12/01 AL 4.000 8.000 12.000 15.990 20.000 15.990 12.000 8.000 4.000 547 1E32N061N 10/2/00 AF 4.080 8.040 11.980 15.940 19.940 15.950 11.990 8.030 4.070 548 1E32N061N 10/2100 AL 3.990 8.000 11.990 15.980 19.990 15.980 11.990 7.990 4.010 549 1E32N061N 4/10/99 AF 4.014 7.982 11.993 15.987 19.983 15.990 11.989 7.992 4.012 550 1E32N061N 4/10/99 AL 4.014 7.982 11.993 15.987 19.983 15.990 11.989 7.992 4.012 551 1E32N061N 1017197 AF 4.030 8.030 12.020 15.970 19.970 15.980 12.010 8.000 3.990 552 1E32N061N 1017197 AL 4.030 8.030 12.020 15.970 19.970 15.980 12.010 8.000 3.990 553 1E51 N035A 4/24/10 AF 4.030 8.040 11.900 15.910 19.920 15.930 11.910 8.050 4.020 554 1E51N035A 4/24/10 AL 4.030 8.040 11.900 15.910 19.920 15.930 11.910 8.050 4.020 555 1E51N035A 7/2/08 AF 4.010 8.040 11.890 15.910 19.930 15.920 11.890 8.040 4.020 556 1E51 N035A 7/2/08 AL 4.030 8.050 11.910 15.920 19.930 15.920 11.900 8.050 4.030 557 1E51N035A 211/08 AF 4.020 8.040 11.900 15.920 19.920 15.920 11.910 8.040 4.020 558 1E51 N035A 211/08 AL 4.020 8.040 11.900 15.920 19.920 15.920 11.910 8.040 4.020 559 1E51N035A 8/5/06 AF EXC EXC EXC EXC EXC EXC EXC EXC EXC 560 1E51 N035A 8/5/06 AL 4.030 8.050 11.900 15.920 19.940 15.920 11.900 8.040 4.010

DRIFT ANALYSIS ENGINEERING DEPARTMENT GRAND GULF NUCLEAR STATION Rosemount Range Codes 5 - 8 Gage Pressure Transmitters Data Conversion JC-Q1111-09019 Rev. 0 Page 75 of 134 IDENTIFYING INFORMATION ACTUAL AF/AL RAW VALUES Seq. 10 Tag 10 Date AF/AL 1

2 3

4 5

6 7

8 9

(0% Up)

(25% Up)

(50% Up)

(75% Up)

(100% Up)

(75% On)

(50% On)

(25% On)

(0% On) 561 1E51N035E 4/25/10 AF 4.070 8.050 11.890 15.920 19.960 15.930 11.900 8.060 4.070 562 1E51N035E 4/25/10 AL 4.020 8.020 11.870 15.890 19.940 15.890 11.880 8.020 4.020 563 1E51N035E 6/30/08 AF 4.030 8.050 11.910 15.940 19.950 15.930 11.920 8.050 4.020 564 1E51 N035E 6/30/08 AL 4.040 8.040 11.890 15.920 19.960 15.920 11.900 8.040 4.040 565 1E51N035E 10/8/06 AF EXC EXC EXC EXC EXC EXC EXC EXC EXC 566 1E51N035E 10/8/06 AL 4.020 8.040 11.900 15.920 19.940 15.920 11.900 8.050 4.030 567 1E51N055A 6/29/09 AF 4.010 8.000 12.000 15.990 20.000 16.000 12.000 8.000 4.010 568 1E51N055A 6/29/09 AL 4.010 8.000 12.000 15.990 20.000 16.000 12.000 8.000 4.010 569 1E51N055A 1/2/08 AF 4.000 8.000 12.000 16.000 20.020 16.000 12.000 8.000 4.000 570 1E51N055A 1/2/08 AL 4.000 8.000 12.000 16.000 20.020 16.000 12.000 8.000 4.000 571 1E51N055A 3/18/06 AF 4.000 8.000 12.010 16.020 20.030 16.020 12.020 8.010 4.000 572 1E51 N055A 3/18/06 AL 4.000 8.000 12.010 16.020 20.030 16.020 12.020 8.010 4.000 573 1E51 N055A 8/4/04 AF 4.010 8.000 12.000 16.000 20.010 16.000 12.000 8.000 4.000 574 1E51 N055A 8/4/04 AL 4.010 8.000 12.000 16.000 20.010 16.000 12.000 8.000 4.000 575 1E51N055A 2/19/03 AF 3.980 7.970 11.960 15.950 19.950 15.950 11.960 7.970 3.980 576 1E51N055A 2/19/03 AL 4.000 8.000 12.000 16.000 20.000 16.000 12.000 8.000 4.000 577 1E51N055A 4/24/01 AF 3.980 7.980 11.970 15.970 19.970 15.970 11.970 7.980 3.980 578 1E51N055A 4/24/01 AL 3.980 7.980 11.970 15.970 19.970 15.970 11.970 7.980 3.980 579 1E51 N055A 10/29/99 AF 4.000 8.010 11.990 15.990 19.970 15.980 11.990 8.000 4.000 580 1E51N055A 10/29/99 AL 4.000 8.010 11.990 15.990 19.970 15.980 11.990 8.000 4.000 581 1E51 N055A 4/20/98 AF 4.000 7.970 11.940 15.920 19.910 15.920 11.940 7.970 4.000 582 1E51N055A 4/20/98 AL 3.990 7.990 11.990 15.990 19.990 15.990 11.990 7.990 3.990 583 1E51N0558 11/4/10 AF 3.990 7.990 11.990 15.980 19.980 15.980 11.990 7.990 3.990 584 1E51N0558 11/4/10 AL 3.990 7.990 11.990 15.980 19.980 15.980 11.990 7.990 3.990 585 1E51N0558 1/22/09 AF 4.000 8.000 12.000 16.000 20.000 16.000 12.000 8.000 4.000 586 1E51N0558 1/22/09 AL 4.000 8.000 12.000 16.000 20.000 16.000 12.000 8.000 4.000 587 1E51 N0558 8/10/07 AF 3.990 7.990 11.990 15.990 20.000 15.990 11.990 7.990 3.990 588 1E51 N0558 8/10/07 AL 3.990 7.990 11.990 15.990 20.000 15.990 11.990 7.990 3.990 589 1E51N0558 219/06 AF 3.990 7.990 11.990 15.990 20.000 15.990 11.990 7.990 3.990 590 1E51N0558 219/06 AL 3.990 7.990 11.990 15.990 20.000 15.990 11.990 7.990 3.990 591 1E51N0558 5/4/04 AF 3.990 7.990 11.990 16.000 20.020 16.000 11.990 7.990 4.000 592 1E51 N0558 5/4/04 AL 3.990 7.990 11.990 16.000 20.020 16.000 11.990 7.990 4.000 593 1E51 N0558 11/20/02 AF 3.990 8.000 12.000 16.000 20.020 16.010 12.000 8.000 4.000 594 1E51N0558 11/20/02 AL 3.990 8.000 12.000 16.000 20.020 16.010 12.000 8.000 4.000 595 1E51N0558 4/20/01 AF 3.990 8.000 11.980 16.000 20.010 16.000 11.980 7.990 4.000 596 1E51N0558 4/20/01 AL 3.990 8.000 11.980 16.000 20.010 16.000 11.980 7.990 4.000 597 1E51 N0558 11/16/99 AF 3.990 7.990 12.000 16.010 20.020 16.010 11.990 7.990 3.990 598 1E51N0558 11/16/99 AL 3.990 7.990 12.000 16.010 20.020 16.010 11.990 7.990 3.990 599 1E51N0558 4/20/98 AF 4.000 7.990 12.000 16.010 20.020 16.010 12.000 8.000 3.990 600 1E51N0558 4/20/98 AL 4.000 7.990 12.000 16.010 20.020 16.010 12.000 8.000 3.990 601 1E51 N055E 2/26/10 AF 3.970 7.970 11.970 15.980 20.000 15.990 11.990 8.000 3.980 602 1E51 N055E 2/26/10 AL 3.970 7.970 11.970 15.980 20.000 15.990 11.990 8.000 3.980 603 1E51N055E 7/3/08 AF 3.980 7.980 11.980 15.990 20.010 16.000 12.000 7.990 3.990 604 1E51N055E 7/3/08 AL 3.980 7.980 11.980 15.990 20.010 16.000 12.000 7.990 3.990 605 1E51N055E 10/10/06 AF 3.980 7.980 11.990 15.990 19.990 16.000 11.990 7.990 3.990 606 1E51N055E 10/10/06 AL 3.980 7.980 11.990 15.990 19.990 16.000 11.990 7.990 3.990 607 1E51N055E 12121/04 AF 3.970 7.980 11.980 15.990 20.000 15.990 11.980 7.980 3.980

DRIFT ANALYSIS ENGINEERING DEPARTMENT GRAND GULF NUCLEAR STATION Rosemount Range Codes 5 - 8 Gage Pressure Transmitters Data Conversion JC-Q1111-09019 Rev. 0 Page 76 of 134 IDENTIFYING INFORMATION ACTUAL AF/AL RAW VALUES Seq. 10 Tag 10 Date AF/AL 1

2 3

4 5

6 7

8 9

(0% Up)

(25% Up)

(50% Up)

(75% Up)

(100% Up)

(75% On)

(50% On)

(25% On)

(0% On) 608 1E51 N055E 12121/04 AL 3.970 7.980 11.980 15.990 20.000 15.990 11.980 7.980 3.980 609 1E51N055E 2/19/03 AF 3.960 7.970 11.970 15.980 19.980 15.990 11.990 7.980 3.970 610 1E51N055E 2/19/03 AL 3.960 7.970 11.970 15.980 19.980 15.990 11.990 7.980 3.970 611 1E51N055E 4/25/01 AF 3.980 8.000 12.010 16.010 20.030 16.020 12.020 8.010 3.990 612 1E51N055E 4/25/01 AL 3.980 8.000 12.010 16.010 20.030 16.020 12.020 8.010 3.990 613 1E51N055E 10/29/99 AF 3.980 7.990 11.990 16.020 20.000 16.010 12.000 7.990 3.980 614 1E51N055E 10/29/99 AL 3.980 7.990 11.990 16.020 20.000 16.010 12.000 7.990 3.980 615 1E51 N055E 4/20/98 AF 3.960 7.980 11.980 16.000 20.010 16.010 12.010 7.990 3.970 616 1E51 N055E 4/20/98 AL 3.960 7.980 11.980 16.000 20.010 16.010 12.010 7.990 3.970 617 1E51N055F 6/9/09 AF 4.010 8.000 11.990 16.000 20.010 16.000 12.000 8.010 4.020 618 1E51N055F 6/9/09 AL 4.010 8.000 11.990 16.000 20.010 16.000 12.000 8.010 4.020 619 1E51N055F 9/20/07 AF 4.010 8.010 12.010 16.010 20.020 16.010 12.010 8.010 4.020 620 1E51N055F 9/20/07 AL 4.010 8.010 12.010 16.010 20.020 16.010 12.010 8.010 4.020 621 1E51N055F 1/24/06 AF 4.010 8.000 11.990 16.000 20.010 16.000 11.990 8.000 4.010 622 1E51N055F 1/24/06 AL 4.010 8.000 11.990 16.000 20.010 16.000 11.990 8.000 4.010 623 1E51N055F 5/6/04 AF 3.990 7.990 11.990 15.990 20.000 15.990 11.990 8.000 4.000 624 1E51N055F 5/6/04 AL 3.990 7.990 11.990 15.990 20.000 15.990 11.990 8.000 4.000 625 1E51N055F 11/21/02 AF 4.010 8.000 11.990 16.000 20.000 16.000 11.990 8.000 4.010 626 1E51N055F 11/21/02 AL 4.010 8.000 11.990 16.000 20.000 16.000 11.990 8.000 4.010 627 1E51N055F 4/20/01 AF 3.990 8.000 11.990 16.000 20.020 15.990 11.980 7.990 4.010 628 1E51N055F 4/20/01 AL 3.990 8.000 11.990 16.000 20.020 15.990 11.980 7.990 4.010 629 1E51N055F 11/16/99 AF 4.000 8.020 12.020 16.030 20.040 16.040 12.030 8.020 4.000 630 1E51N055F 11/16/99 AL 4.000 7.990 11.980 16.000 20.010 16.000 11.980 7.990 4.000 631 1E51N055F 4/20/98 AF 3.990 7.970 11.960 15.950 19.950 15.950 11.960 7.960 3.990 632 1E51N055F 4/20/98 AL 4.000 8.000 11.990 15.990 20.000 16.000 12.000 8.000 4.000

DRIFT ANALYSIS ENGINEERING DEPARTMENT GRAND GULF NUCLEAR STATION Rosemount Range Codes 5 - 8 Gage Pressure Transmitters Data Conversion JC-Q1111-09019 Rev. 0 Page 77 of 134 IDENTIFYING INFORMATION RANGE VALUES AF/AL CONVERTED TO "10 SPAN (AFAL-Min)*100"lo/Span Seq.

Span 1

2 3

4 5

6 7

8 9

10 Tag 10 Date AF/AL Min Max (Max-Min)

Units (0"10 Up)

(25"10 Up)

(50"10 Up)

(75"10 Up)

(100"10 Up)

(75"10 On)

(50"10 On)

(25"10 On)

(0"10 On) 1 1B21N201A 6/17109 AF 4.0 20.0 16.0 mAde 0.12500 25.06250 50.00000 75.00000 99.93750 75.00000 50.06250 25.06250 0.12500 2

1B21N201A 6/17/09 AL 4.0 20.0 16.0 mAde 0.12500 25.06250 50.00000 75.00000 99.93750 75.00000 50.06250 25.06250 0.12500 3

1B21N201A 8/28/07 AF 4.0 20.0 16.0 mAde 0.12500 25.06250 50.00000 74.93750 99.87500 74.93750 50.00000 25.06250 0.12500 4

1B21N201A 8/28107 AL 4.0 20.0 16.0 mAde 0.12500 25.06250 50.00000 74.93750 99.87500 74.93750 50.00000 25.06250 0.12500 5

1B21N201A 11/8/05 AF 4.0 20.0 16.0 mAde

-0.12500 25.12500 50.31250 75.62500 101.31250 75.75000 50.31250 25.18750

-0.12500 6

1B21N201A 11/8/05 AL 4.0 20.0 16.0 mAde 0.06250 25.00000 50.00000 75.00000 100.00000 75.00000 50.00000 25.00000 0.06250 7

1B21N201A 5/11/04 AF 4.0 20.0 16.0 mAde 0.06250 25.12500 50.18750 75.25000 100.31250 75.25000 50.18750 25.12500 0.12500 8

1B21N201A 5/11/04 AL 4.0 20.0 16.0 mAde

-0.12500 24.93750 50.00000 75.06250 100.12500 75.06250 50.00000 24.93750

-0.06250 9

1B21N201A 11/25/02 AF 4.0 20.0 16.0 mAde 0.06250 25.06250 50.06250 75.06250 100.12500 75.12500 50.12500 25.06250 0.06250 10 1B21N201A 11/25/02 AL 4.0 20.0 16.0 mAde 0.06250 25.06250 50.06250 75.06250 100.12500 75.12500 50.12500 25.06250 0.06250 11 1B21N201A 4/24/01 AF 4.0 20.0 16.0 mAde 0.43750 25.00000 49.93750 74.87500 99.87500 75.00000 50.00000 25.00000 0.43750 12 1B21N201A 4/24/01 AL 4.0 20.0 16.0 mAde 0.12500 24.87500 49.93750 75.00000 100.06250 75.00000 49.93750 24.81250 0.18750 13 1B21N201A 10/28/99 AF 4.0 20.0 16.0 mAde

-0.01250 24.93750 50.13125 75.01250 99.88750 75.05625 50.08125 24.91875 0.00625 14 1B21N201A 10/28/99 AL 4.0 20.0 16.0 mAde

-0.01250 24.93750 50.13125 75.01250 99.88750 75.05625 50.08125 24.91875 0.00625 15 1B21N201A 4/21/98 AF 4.0 20.0 16.0 mAde 0.06250 25.00000 50.00000 74.93750 99.93750 74.93750 50.00000 25.00000 0.06250 16 1B21N201A 4/21/98 AL 4.0 20.0 16.0 mAde 0.06250 25.00000 50.00000 74.93750 99.93750 74.93750 50.00000 25.00000 0.06250 17 1B21N201B 12/3/10 AF 4.0 20.0 16.0 mAde 0.18750 25.18750 50.06250 75.06250 100.06250 75.06250 50.06250 25.18750 0.18750 18 1B21N201B 12/3110 AL 4.0 20.0 16.0 mAde 0.18750 25.18750 50.06250 75.06250 100.06250 75.06250 50.06250 25.18750 0.18750 19 1B21N201B 3/31/09 AF 4.0 20.0 16.0 mAde 0.12500 25.12500 50.06250 75.06250 100.06250 75.06250 50.06250 25.12500 0.12500 20 1B21N201B 3/31/09 AL 4.0 20.0 16.0 mAde 0.12500 25.12500 50.06250 75.06250 100.06250 75.06250 50.06250 25.12500 0.12500 21 1B21N201B 10/12/07 AF 4.0 20.0 16.0 mAde 0.12500 25.06250 50.08750 75.00000 100.06250 75.06250 50.06250 25.06250 0.12500 22 1B21N201B 10/12/07 AL 4.0 20.0 16.0 mAde 0.12500 25.06250 50.08750 75.00000 100.06250 75.06250 50.06250 25.06250 0.12500 23 1B21N201B 3/8/06 AF 4.0 20.0 16.0 mAde 0.12500 25.06250 50.08750 75.12500 100.00000 75.12500 50.06250 25.12500 0.12500 24 1B21N201B 3/8/06 AL 4.0 20.0 16.0 mAde 0.12500 25.06250 50.08750 75.12500 100.00000 75.12500 50.06250 25.12500 0.12500 25 1B21N201B 7/15/04 AF 4.0 20.0 16.0 mAde 0.12500 25.12500 50.12500 75.12500 100.12500 75.12500 50.12500 25.18750 0.12500 26 1B21N201B 7/15/04 AL 4.0 20.0 16.0 mAde 0.12500 25.12500 50.12500 75.12500 100.12500 75.12500 50.12500 25.18750 0.12500 27 1B21N201B 10/24/02 AF 4.0 20.0 16.0 mAde 0.12500 24.93750 50.06250 74.87500 99.87500 74.87500 49.93750 24.93750 0.00000 28 1B21N201B 10/24/02 AL 4.0 20.0 16.0 mAde 0.12500 24.93750 50.06250 74.87500 99.87500 74.87500 49.93750 24.93750 0.00000 29 1B21N201B 4/23/01 AF 4.0 20.0 16.0 mAde 0.06250 25.06250 50.06250 75.06250 100.06250 75.06250 50.06250 25.06250 0.06250 30 1B21N201B 4/23/01 AL 4.0 20.0 16.0 mAde 0.06250 25.06250 50.06250 75.06250 100.06250 75.06250 50.06250 25.06250 0.06250 31 1B21N201B 11/5/99 AF 4.0 20.0 16.0 mAde 0.06250 25.06250 50.00000 74.93750 100.06250 75.06250 50.18750 25.12500 0.12500 32 1B21N201B 11/5/99 AL 4.0 20.0 16.0 mAde 0.06250 25.06250 50.00000 74.93750 100.06250 75.06250 50.18750 25.12500 0.12500 33 1B21N201B 4/16/98 AF 4.0 20.0 16.0 mAde 0.00000 25.00000 50.12500 75.12500 100.12500 75.06250 50.12500 25.00000 0.06250 34 1B21N201B 4/16/98 AL 4.0 20.0 16.0 mAde 0.00000 25.00000 50.12500 75.12500 100.12500 75.06250 50.12500 25.00000 0.06250 35 1C61N102 8/12109 AF 4.0 20.0 16.0 mAde 0.00000 24.93750 49.93750 75.00000 99.93750 75.00000 49.93750 25.00000 0.00000 36 1C61N102 8/12109 AL 4.0 20.0 16.0 mAde 0.00000 24.93750 49.93750 75.00000 99.93750 75.00000 49.93750 25.00000 0.00000 37 1C61N102 2115/08 AF 4.0 20.0 16.0 mAde

-0.06250 24.93750 50.00000 75.00000 100.06250 75.06250 50.00000 25.00000

-0.06250 38 1C61N102 2/15/08 AL 4.0 20.0 16.0 mAde

-0.06250 24.93750 50.00000 75.00000 100.06250 75.06250 50.00000 25.00000

-0.06250 39 1C61N102 8/31/06 AF 4.0 20.0 16.0 mAde

-0.18750 24.81250 49.87500 74.93750 100.00000 75.00000 49.93750 24.81250

-0.18750 40 1C61N102 8/31/06 AL 4.0 20.0 16.0 mAde

-0.18750 24.81250 49.87500 74.93750 100.00000 75.00000 49.93750 24.81250

-0.18750 41 1C61N102 1/19/05 AF 4.0 20.0 16.0 mAde

-0.25000 24.75000 49.75000 74.81250 99.87500 74.81250 49.81250 24.75000

-0.25000 42 1C61N102 1119/05 AL 4.0 20.0 16.0 mAde

-0.25000 24.75000 49.75000 74.81250 99.87500 74.81250 49.81250 24.75000

-0.25000 43 1C61N102 817103 AF 4.0 20.0 16.0 mAde 0.00000 24.93750 49.93750 74.93750 99.93750 74.93750 50.00000 25.00000 0.00000 44 1C61N102 817103 AL 4.0 20.0 16.0 mAde 0.00000 24.93750 49.93750 74.93750 99.93750 74.93750 50.00000 25.00000 0.00000 45 1C61N102 2/8/02 AF 4.0 20.0 16.0 mAde 0.12500 25.12500 50.12500 75.12500 100.18750 75.18750 50.18750 25.18750 0.12500 46 1C61N102 218/02 AL 4.0 20.0 16.0 mAde 0.00000 25.00000 50.00000 75.00000 100.00000 75.00000 50.00000 25.00000 0.00000 47 1C61N102 8/15/00 AF 4.0 20.0 16.0 mAde 0.00000 25.00000 50.12500 75.00000 100.06250 75.06250 50.12500 25.06250 0.06250

DRIFT ANALYSIS ENGINEERING DEPARTMENT GRAND GULF NUCLEAR STATION Rosemount Range Codes 5 - 8 Gage Pressure Transmitters Data Conversion JC-Q1111-09019 Rev. 0 Page 78 of 134 IDENTIFYING INFORMATION RANGE VALUES AF/AL CONVERTED TO % SPAN (AFAL-Min)*100%/Span Seq.

Span 1

2 3

4 5

6 7

8 9

10 Tag 10 Date AF/AL Min Max (Max-Min)

Units (0% Up)

(25% Up)

(50% Up)

(75% Up)

(100% Up)

(75% On)

(50% On)

(25% On)

(0% On) 48 1C61N102 8/15/00 AL 4.0 20.0 16.0 mAde 0.00000 25.00000 50.12500 75.00000 100.06250 75.06250 50.12500 25.06250 0.06250 49 1C61N102 3/29/99 AF 4.0 20.0 16.0 mAde 0.18750 25.06250 50.06250 75.06250 100.12500 75.06250 50.06250 25.06250 0.18750 50 1C61N102 3/29/99 AL 4.0 20.0 16.0 mAde 0.18750 25.06250 50.06250 75.06250 100.12500 75.06250 50.06250 25.06250 0.18750 51 1E12N053A 8112/09 AF 4.0 20.0 16.0 mAde 1.18750 25.00000 50.00000 75.00000 100.00000 75.00000 50.06250 25.06250 1.12500 52 1E12N053A 8/12109 AL 4.0 20.0 16.0 mAde 1.18750 25.00000 50.00000 75.00000 100.00000 75.00000 50.06250 25.06250 1.12500 53 1E12N053A 2/15/08 AF 4.0 20.0 16.0 mAde 0.81250 24.75000 49.68750 74.68750 99.68750 74.75000 49.75000 24.75000 0.93750 54 1E12N053A 2115/08 AL 4.0 20.0 16.0 mAde 1.18750 25.00000 49.93750 74.93750 99.93750 75.00000 50.00000 25.00000 1.18750 55 1E12N053A 8/30/06 AF 4.0 20.0 16.0 mAde 0.93750 24.81250 49.87500 74.81250 99.81250 74.87500 49.81250 24.81250 1.00000 56 1E12N053A 8/30/06 AL 4.0 20.0 16.0 mAde 0.93750 24.81250 49.87500 74.81250 99.81250 74.87500 49.81250 24.81250 1.00000 57 1E12N053A 3/17/05 AF 4.0 20.0 16.0 mAde 0.93750 24.81250 49.75000 74.75000 99.75000 74.81250 49.81250 24.87500 1.00000 58 1E12N053A 3117/05 AL 4.0 20.0 16.0 mAde 0.93750 24.81250 49.75000 74.75000 99.75000 74.81250 49.81250 24.87500 1.00000 59 1E12N053A 10/3/03 AF 4.0 20.0 16.0 mAde 0.93750 24.81250 49.81250 74.81250 99.81250 74.87500 49.87500 24.87500 0.93750 60 1E12N053A 10/3/03 AL 4.0 20.0 16.0 mAde 0.93750 24.81250 49.81250 74.81250 99.81250 74.87500 49.87500 24.87500 0.93750 61 1E12N053A 4/17/02 AF 4.0 20.0 16.0 mAde 1.00000 25.00000 50.00000 75.00000 100.00000 75.06250 50.06250 25.00000 1.00000 62 1E12N053A 4/17/02 AL 4.0 20.0 16.0 mAde 1.00000 25.00000 50.00000 75.00000 100.00000 75.06250 50.06250 25.00000 1.00000 63 1E12N053A 10/16/00 AF 4.0 20.0 16.0 mAde 1.06250 24.93750 50.06250 75.00000 100.06250 75.00000 50.06250 24.93750 1.06250 64 1E12N053A 10/16/00 AL 4.0 20.0 16.0 mAde 1.06250 24.93750 50.06250 75.00000 100.06250 75.00000 50.06250 24.93750 1.06250 65 1E12N053A 3/22/99 AF 4.0 20.0 16.0 mAde 0.93750 24.87500 50.06250 74.93750 100.25000 75.06250 50.06250 24.87500 1.00000 66 1E12N053A 3/22199 AL 4.0 20.0 16.0 mAde 1.00000 24.93750 50.06250 75.06250 99.93750 75.00000 50.00000 24.87500 1.00000 67 1E12N053A 8/26/97 AF 4.0 20.0 16.0 mAde 1.05625 24.93750 50.06250 75.05000 100.07500 75.06875 50.08125 24.96875 1.05625 68 1E12N053A 8/26/97 AL 4.0 20.0 16.0 mAde 1.05625 24.93750 50.06250 75.05000 100.07500 75.06875 50.08125 24.96875 1.05625 69 1E12N053B 12114/09 AF 4.0 20.0 16.0 mAde 0.87500 25.00000 49.93750 74.93750 99.93750 74.93750 50.00000 25.06250 0.93750 70 1E12N053B 12114/09 AL 4.0 20.0 16.0 mAde 0.87500 25.00000 49.93750 74.93750 99.93750 74.93750 50.00000 25.06250 0.93750 71 1E12N053B 5/29/08 AF 4.0 20.0 16.0 mAde 1.00000 25.06250 50.00000 75.00000 100.00000 75.12500 50.06250 25.12500 1.25000 72 1E12N053B 5/29/08 AL 4.0 20.0 16.0 mAde 1.00000 25.06250 50.00000 75.00000 100.00000 75.12500 50.06250 25.12500 1.25000 73 1E12N053B 11/29/06 AF 4.0 20.0 16.0 mAde 1.00000 24.81250 49.75000 74.68750 99.68750 74.68750 49.75000 24.81250 1.00000 74 1E12N053B 11/29/06 AL 4.0 20.0 16.0 mAde 1.25000 25.00000 49.93750 74.93750 99.87500 75.00000 50.00000 25.06250 1.25000 75 1E12N053B 5/20/05 AF 4.0 20.0 16.0 mAde 1.00000 24.81250 49.81250 74.81250 99.81250 74.87500 49.87500 24.87500 1.00000 76 1E12N053B 5/20/05 AL 4.0 20.0 16.0 mAde 1.00000 24.81250 49.81250 74.81250 99.81250 74.87500 49.87500 24.87500 1.00000 77 1E12N053B 11/20/03 AF 4.0 20.0 16.0 mAde 1.00000 24.81250 49.75000 74.81250 99.81250 74.87500 49.87500 24.93750 1.00000 78 1E12N053B 11/20/03 AL 4.0 20.0 16.0 mAde 1.00000 24.81250 49.75000 74.81250 99.81250 74.87500 49.87500 24.93750 1.00000 79 1E12N053B 7/17/02 AF 4.0 20.0 16.0 mAde 1.12500 24.93750 49.87500 74.87500 99.87500 74.93750 50.00000 25.00000 1.18750 80 1E12N053B 7117/02 AL 4.0 20.0 16.0 mAde 1.12500 24.93750 49.87500 74.87500 99.87500 74.93750 50.00000 25.00000 1.18750 81 1E12N053B 9/28/00 AF 4.0 20.0 16.0 mAde 1.12500 24.87500 50.00000 75.00000 99.87500 75.00000 49.93750 24.93750 1.12500 82 1E12N053B 9/28/00 Al 4.0 20.0 16.0 mAde 1.12500 24.87500 50.00000 75.00000 99.87500 75.00000 49.93750 24.93750 1.12500 83 1E12N053B 3/18/99 AF 4.0 20.0 16.0 mAde 1.00000 25.00000 49.93750 75.00000 99.93750 75.06250 50.06250 25.06250 0.93750 84 1E12N053B 3/18/99 AL 4.0 20.0 16.0 mAde 1.00000 25.00000 49.93750 75.00000 99.93750 75.06250 50.06250 25.06250 0.93750 85 1E12N053B 8/20/97 AF 4.0 20.0 16.0 mAde 1.10000 25.03750 50.13125 75.08125 100.23750 75.18125 50.15625 25.10625 1.13125 86 1E12N053B 8/20/97 Al 4.0 20.0 16.0 mAde 1.10000 25.03750 50.13125 75.08125 100.23750 75.18125 50.15625 25.10625 1.13125 87 1E12N053C 11/4/10 AF 4.0 20.0 16.0 mAde 0.12500 24.87500 49.87500 74.87500 99.87500 74.93750 49.93750 24.93750 0.18750 88 1E12N053C 11/4/10 Al 4.0 20.0 16.0 mAde 0.12500 24.87500 49.87500 74.87500 99.87500 74.93750 49.93750 24.93750 0.18750 89 1E12N053C 5/11/09 AF 4.0 20.0 16.0 mAde 0.18750 24.93750 50.00000 74.93750 99.93750 75.00000 50.06250 25.00000 0.18750 90 1E12N053C 5/11/09 Al 4.0 20.0 16.0 mAde 0.18750 24.93750 50.00000 74.93750 99.93750 75.00000 50.06250 25.00000 0.18750 91 1E12N053C 9/17107 AF 4.0 20.0 16.0 mAde 0.12500 24.81250 49.81250 74.81250 99.81250 74.93750 49.93750 24.93750 0.18750 92 1E12N053C 9/17107 Al 4.0 20.0 16.0 mAde 0.12500 24.81250 49.81250 74.81250 99.81250 74.93750 49.93750 24.93750 0.18750 93 1E12N053C 1/23/06 AF 4.0 20.0 16.0 mAde 0.31250 24.93750 49.87500 74.87500 99.87500 74.93750 50.00000 25.00000 0.31250 94 1E12N053C 1/23/06 Al 4.0 20.0 16.0 mAde 0.31250 24.93750 49.87500 74.87500 99.87500 74.93750 50.00000 25.00000 0.31250

DRIFT ANALYSIS ENGINEERING DEPARTMENT GRAND GULF NUCLEAR STATION Rosemount Range Codes 5 - 8 Gage Pressure Transmitters Data Conversion JC-Q1111-09019 Rev. 0 Page 79 of 134 IDENTIFYING INFORMATION RANGE VALUES AF/AL CONVERTED TO % SPAN (AFAL-Min)*100%/Span Seq.

Tag 10 Date AF/AL Min Max Span 1

2 3

4 5

6 7

8 9

10 (Max-Min)

Units (0% Up)

(25% Up)

(50% Up)

(75% Up)

(100% Up)

(75% On)

(50% On)

(25% On)

(0% On) 95 1E12N053C 417104 AF 4.0 20.0 16.0 mAde 0.25000 24.93750 49.93750 74.93750 99.87500 75.00000 50.00000 25.00000 0.25000 96 1E12N053C 417104 AL 4.0 20.0 16.0 mAde 0.25000 24.93750 49.93750 74.93750 99.87500 75.00000 50.00000 25.00000 0.25000 97 1E12N053C 7/17102 AF 4.0 20.0 16.0 mAde 0.25000 25.00000 50.00000 75.00000 99.93750 75.06250 50.06250 25.06250 0.25000 98 1E12N053C 7/17102 AL 4.0 20.0 16.0 mAde 0.25000 25.00000 50.00000 75.00000 99.93750 75.06250 50.06250 25.06250 0.25000 99 1E12N053C 10/24/00 AF 4.0 20.0 16.0 mAde 0.25000 24.93750 49.93750 74.81250 99.93750 75.00000 49.93750 24.93750 0.25000 100 1E12N053C 10/24/00 AL 4.0 20.0 16.0 mAde 0.25000 24.93750 49.93750 74.81250 99.93750 75.00000 49.93750 24.93750 0.25000 101 1E12N053C 3/18/99 AF 4.0 20.0 16.0 mAde 0.25000 25.00000 50.00000 75.00000 99.93750 75.06250 50.06250 25.12500 0.25000 102 1E12N053C 3/18/99 AL 4.0 20.0 16.0 mAde 0.25000 25.00000 50.00000 75.00000 99.93750 75.06250 50.06250 25.12500 0.25000 103 1E12N053C 8/20/97 AF 4.0 20.0 16.0 mAde 0.33125 25.13125 49.98750 75.13750 100.06250 74.90000 50.18750 25.06875 0.36250 104 1E12N053C 8/20/97 AL 4.0 20.0 16.0 mAde 0.33125 25.13125 49.98750 75.13750 100.06250 74.90000 50.18750 25.06875 0.36250 105 1E12N055A 12/22/09 AF 4.0 20.0 16.0 mAde 2.12500 25.12500 50.06250 75.12500 100.18750 75.12500 50.06250 25.12500 2.12500 106 1E12N055A 12122/09 AL 4.0 20.0 16.0 mAde 2.12500 25.12500 50.06250 75.12500 100.18750 75.12500 50.06250 25.12500 2.12500 107 1E12N055A 6/30/08 AF 4.0 20.0 16.0 mAde 2.00000 24.93750 49.87500 74.93750 100.12500 74.93750 49.93750 24.93750 2.00000 108 1E12N055A 6/30/08 AL 4.0 20.0 16.0 mAde 2.00000 24.93750 49.87500 74.93750 100.12500 74.93750 49.93750 24.93750 2.00000 109 1E12N055A 9/14/06 AF 4.0 20.0 16.0 mAde 2.06250 25.00000 49.93750 75.06250 100.18750 75.06250 50.00000 25.06250 2.06250 110 1E12N055A 9/14/06 AL 4.0 20.0 16.0 mAde 2.06250 25.00000 49.93750 75.06250 100.18750 75.06250 50.00000 25.06250 2.06250 111 1E12N055A 1/17105 AF 4.0 20.0 16.0 mAde 1.81250 24.75000 49.68750 74.62500 99.81250 74.68750 49.68750 24.75000 1.87500 112 1E12N055A 1/17/05 AL 4.0 20.0 16.0 mAde 2.06250 24.93750 49.93750 74.93750 100.12500 74.93750 49.93750 25.00000 2.06250 113 1E12N055A 9/3/03 AF 4.0 20.0 16.0 mAde 1.87500 24.87500 49.81250 74.87500 99.93750 74.87500 49.87500 24.87500 1.81250 114 1E12N055A 9/3/03 AL 4.0 20.0 16.0 mAde 1.87500 24.87500 49.81250 74.87500 99.93750 74.87500 49.87500 24.87500 1.81250 115 1E12N055A 3/8/02 AF 4.0 20.0 16.0 mAde 1.81250 25.18750 49.93750 75.12500 100.18750 74.93750 49.93750 25.18750 1.81250 116 1E12N055A 3/8/02 AL 4.0 20.0 16.0 mAde 1.93750 24.93750 49.93750 74.93750 100.06250 74.93750 49.93750 25.00000 1.93750 117 1E12N055A 10/4/00 AF 4.0 20.0 16.0 mAde 2.06250 25.12500 50.18750 75.25000 100.43750 75.18750 50.25000 25.31250 2.06250 118 1E12N055A 10/4/00 AL 4.0 20.0 16.0 mAde 1.87500 25.06250 49.93750 75.00000 100.00000 75.00000 50.06250 25.06250 1.93750 119 1E12N055A 4/11/99 AF 4.0 20.0 16.0 mAde 2.14375 25.09375 50.00000 74.95625 100.16250 74.90625 50.01875 24.90625 2.11875 120 1E12N055A 4/11/99 AL 4.0 20.0 16.0 mAde 2.14375 25.09375 50.00000 74.95625 100.16250 74.90625 50.01875 24.90625 2.11875 121 1E12N055A 8/30/97 AF 4.0 20.0 16.0 mAde 2.08750 25.09375 49.95000 74.92500 100.06250 74.88125 50.06875 25.13750 2.10625 122 1E12N055A 8/30/97 AL 4.0 20.0 16.0 mAde 2.08750 25.09375 49.95000 74.92500 100.06250 74.88125 50.06875 25.13750 2.10625 123 1E12N055B 1/21/10 AF 4.0 20.0 16.0 mAde 2.06250 25.00000 49.87500 74.87500 99.93750 74.87500 49.87500 25.00000 2.06250 124 1E12N055B 1/21/10 AL 4.0 20.0 16.0 mAde 2.06250 25.00000 49.87500 74.87500 99.93750 74.87500 49.87500 25.00000 2.06250 125 1E12N055B 5/29/08 AF 4.0 20.0 16.0 mAde 2.06250 24.87500 49.75000 74.81250 100.00000 74.81250 49.75000 24.87500 2.06250 126 1E12N055B 5/29/08 AL 4.0 20.0 16.0 mAde 2.06250 24.87500 49.75000 74.81250 100.00000 74.81250 49.75000 24.87500 2.06250 127 1E12N055B 11129/06 AF 4.0 20.0 16.0 mAde 2.00000 24.62500 49.56250 74.56250 99.62500 74.56250 49.56250 24.68750 2.00000 128 1E12N055B 11/29/06 AL 4.0 20.0 16.0 mAde 2.12500 24.93750 49.81250 74.93750 100.06250 74.93750 49.81250 24.93750 2.12500 129 1E12N055B 5/20/05 AF 4.0 20.0 16.0 mAde 2.12500 24.87500 49.75000 74.81250 99.87500 74.81250 49.81250 24.93750 2.12500 130 1E12N055B 5/20/05 AL 4.0 20.0 16.0 mAde 2.12500 24.87500 49.75000 74.81250 99.87500 74.81250 49.81250 24.93750 2.12500 131 1E12N055B 11/19/03 AF 4.0 20.0 16.0 mAde 2.12500 24.81250 49.68750 74.68750 99.87500 74.75000 49.75000 24.81250 2.06250 132 1E12N055B 11/19/03 AL 4.0 20.0 16.0 mAde 2.18750 24.93750 49.81250 74.87500 100.00000 74.87500 49.81250 24.93750 2.18750 133 1E12N055B 6/4/02 AF 4.0 20.0 16.0 mAde 2.00000 24.87500 49.93750 74.87500 99.62500 74.93750 50.00000 24.93750 2.00000 134 1E12N055B 6/4/02 AL 4.0 20.0 16.0 mAde 2.06250 25.00000 49.93750 75.00000 100.12500 75.00000 49.93750 25.00000 2.06250 135 1E12N055B 12/5/00 AF 4.0 20.0 16.0 mAde 2.00000 24.93750 49.87500 75.00000 99.93750 74.93750 49.87500 24.87500 2.00000 136 1E12N055B 12/5/00 AL 4.0 20.0 16.0 mAde 2.00000 24.93750 49.87500 75.00000 99.93750 74.93750 49.87500 24.87500 2.00000 137 1E12N055B 5/26/99 AF 4.0 20.0 16.0 mAde 2.00000 25.00000 50.10000 75.10625 99.80625 75.21875 50.10625 25.11875 2.00625 138 1E12N055B 5/26/99 AL 4.0 20.0 16.0 mAde 2.00000 25.00000 50.10000 75.10625 99.80625 75.21875 50.10625 25.11875 2.00625 139 1E12N055B 10/16/97 AF 4.0 20.0 16.0 mAde 1.87500 24.93750 49.93750 74.93750 100.00000 74.93750 50.00000 24.87500 1.93750 140 1E12N055B 10/16/97 AL 4.0 20.0 16.0 mAde 1.87500 24.93750 49.93750 74.93750 100.00000 74.93750 50.00000 24.87500 1.93750 141 1E12N055C 1/20/10 AF 4.0 20.0 16.0 mAde 0.43750 25.18750 50.12500 75.12500 100.12500 75.12500 50.12500 25.18750 0.43750

DRIFT ANALYSIS ENGINEERING DEPARTMENT GRAND GULF NUCLEAR STATION Rosemount Range Codes 5 - 8 Gage Pressure Transmitters Data Conversion JC-Q1111-09019 Rev. 0 Page 80 of 134 IDENTIFYING INFORMATION RANGE VALUES AF/AL CONVERTED TO % SPAN (AFAL-Min)*100%/Span Seq.

Tag 10 Span 1

2 3

4 5

6 7

8 9

10 Date AF/AL Min Max (Max-Min)

Units (0% Up)

(25% Up)

(50% Up)

(75% Up)

(100% Up)

(75% On)

(50% On)

(25% On)

(0% On) 142 1E12N055C 1/20/10 AL 4.0 20.0 16.0 mAde 0.43750 25.18750 50.12500 75.12500 100.12500 75.12500 50.12500 25.18750 0.43750 143 1E12N055C 5/29/08 AF 4.0 20.0 16.0 mAde 0.43750 25.06250 50.00000 75.00000 100.00000 75.00000 50.00000 25.06250 0.43750 144 1E12N055C 5/29/08 AL 4.0 20.0 16.0 mAde 0.43750 25.06250 50.00000 75.00000 100.00000 75.00000 50.00000 25.00000 0.43750 145 1E12N055C 11/29/06 AF 4.0 20.0 16.0 mAde

-0.06250 24.75000 49.62500 74.50000 99.56250 74.50000 49.56250 24.87500 0.00000 146 1E12N055C 11/29/06 AL 4.0 20.0 16.0 mAde 0.25000 25.12500 50.06250 75.00000 100.00000 75.00000 50.06250 25.12500 0.25000 147 1E12N055C 5/20/05 AF 4.0 20.0 16.0 mAde 0.43750 25.06250 50.00000 74.93750 99.93750 74.93750 50.00000 25.06250 0.43750 148 1E12N055C 5/20/05 AL 4.0 20.0 16.0 mAde 0.43750 25.06250 50.00000 74.93750 99.93750 74.93750 50.00000 25.06250 0.43750 149 1E12N055C 11/19/03 AF 4.0 20.0 16.0 mAde 0.50000 25.06250 50.00000 75.00000 100.00000 75.00000 50.06250 25.12500 0.50000 150 1E12N055C 11/19/03 AL 4.0 20.0 16.0 mAde 0.50000 25.06250 50.00000 75.00000 100.00000 75.00000 50.06250 25.12500 0.50000 151 1E12N055C 7/3/02 AF 4.0 20.0 16.0 mAde 0.31250 24.87500 49.81250 74.81250 99.75000 74.81250 49.81250 24.87500 0.25000 152 1E12N055C 7/3/02 AL 4.0 20.0 16.0 mAde 0.43750 25.06250 50.00000 74.93750 99.81250 74.93750 50.00000 25.06250 0.43750 153 1E12N055C 12/6/00 AF 4.0 20.0 16.0 mAde 0.31250 24.93750 49.93750 74.87500 99.81250 74.87500 49.87500 24.93750 0.31250 154 1E12N055C 12/6/00 AL 4.0 20.0 16.0 mAde 0.31250 24.93750 49.93750 74.87500 99.81250 74.87500 49.87500 24.93750 0.31250 155 1E12N055C 5/27/99 AF 4.0 20.0 16.0 mAde 0.37500 25.06250 50.12500 75.00000 99.93750 75.06250 50.25000 25.06250 0.31250 156 1E12N055C 5/27/99 AL 4.0 20.0 16.0 mAde 0.37500 25.06250 50.12500 75.00000 99.93750 75.06250 50.25000 25.06250 0.31250 157 1E12N055C 10/16/97 AF 4.0 20.0 16.0 mAde 0.31250 24.87500 49.75000 74.75000 99.81250 74.75000 49.81250 24.81250 0.31250 158 1E12N055C 10/16/97 AL 4.0 20.0 16.0 mAde 0.31250 24.87500 49.75000 74.75000 99.81250 74.75000 49.81250 24.81250 0.31250 159 1E12N056A 12121/09 AF 4.0 20.0 16.0 mAde 2.06250 25.12500 50.18750 75.25000 100.18750 75.25000 50.18750 25.12500 2.06250 160 1E12N056A 12121/09 AL 4.0 20.0 16.0 mAde 1.93750 25.00000 50.00000 75.00000 100.00000 75.00000 50.00000 25.00000 1.93750 161 1E12N056A 6/30/08 AF 4.0 20.0 16.0 mAde 1.50000 24.62500 49.68750 74.68750 99.68750 74.68750 49.68750 24.62500 1.50000 162 1E12N056A 6/30108 AL 4.0 20.0 16.0 mAde 1.93750 25.00000 50.06250 75.12500 100.06250 75.12500 50.12500 25.00000 1.93750 163 1E12N056A 9/15/06 AF 4.0 20.0 16.0 mAde 1.81250 24.93750 50.00000 75.00000 100.00000 75.00000 50.00000 24.93750 1.75000 164 1E12N056A 9/15/06 AL 4.0 20.0 16.0 mAde 1.81250 24.93750 50.00000 75.00000 100.00000 75.00000 50.00000 24.93750 1.75000 165 1E12N056A 1/17105 AF 4.0 20.0 16.0 mAde 1.93750 24.87500 49.93750 74.87500 100.00000 74.93750 50.00000 24.93750 1.87500 166 1E12N056A 1/17/05 AL 4.0 20.0 16.0 mAde 1.93750 24.87500 49.93750 74.87500 100.00000 74.93750 50.00000 24.93750 1.87500 167 1E12N056A 8/6/03 AF 4.0 20.0 16.0 mAde 1.87500 24.87500 50.00000 75.00000 100.06250 75.06250 50.06250 24.87500 1.87500 168 1E12N056A 816/03 AL 4.0 20.0 16.0 mAde 1.87500 24.87500 50.00000 75.00000 100.06250 75.06250 50.06250 24.87500 1.87500 169 1E12N056A 218/02 AF 4.0 20.0 16.0 mAde 1.87500 24.62500 49.43750 74.37500 99.62500 74.37500 49.37500 24.50000 1.81250 170 1E12N056A 218/02 AL 4.0 20.0 16.0 mAde 1.93750 25.00000 49.93750 75.06250 100.00000 75.06250 49.93750 24.93750 1.93750 171 1E12N056A 10/4/00 AF 4.0 20.0 16.0 mAde 1.81250 25.00000 49.93750 75.00000 100.18750 75.06250 50.06250 24.93750 1.87500 172 1E12N056A 10/4/00 AL 4.0 20.0 16.0 mAde 1.81250 25.00000 49.93750 75.00000 100.18750 75.06250 50.06250 24.93750 1.87500 173 1E12N056A 4/11/99 AF 4.0 20.0 16.0 mAde 1.78125 24.88750 49.87500 74.85625 100.00625 74.84375 49.88125 24.85000 1.88125 174 1E12N056A 4/11/99 AL 4.0 20.0 16.0 mAde 1.78125 24.88750 49.87500 74.85625 100.00625 74.84375 49.88125 24.85000 1.88125 175 1E12N056A 8/30/97 AF 4.0 20.0 16.0 mAde 2.09375 24.85000 49.81250 74.69375 100.04375 74.67500 49.73125 25.03750 2.15000 176 1E12N056A 8/30/97 AL 4.0 20.0 16.0 mAde 1.90000 24.92500 49.85000 74.83750 100.05625 74.81875 49.85000 24.91875 1.90000 177 1E12N056B 215/10 AF 4.0 20.0 16.0 mAde 2.18750 25.18750 50.06250 75.06250 100.12500 75.12500 50.12500 25.18750 2.12500 178 1E12N056B 215/10 AL 4.0 20.0 16.0 mAde 2.18750 25.18750 50.06250 75.06250 100.12500 75.12500 50.12500 25.18750 2.12500 179 1E12N056B 7/8/08 AF 4.0 20.0 16.0 mAde 1.68750 24.43750 49.37500 74.37500 99.62500 74.37500 49.37500 24.43750 1.68750 180 1E12N056B 7/8/08 AL 4.0 20.0 16.0 mAde 2.00000 24.81250 49.75000 74.81250 99.93750 74.81250 49.75000 24.81250 2.00000 181 1E12N056B 1/11/07 AF 4.0 20.0 16.0 mAde 2.00000 24.93750 49.87500 74.87500 99.93750 74.93750 49.87500 24.87500 2.06250 182 1E12N056B 1/11/07 AL 4.0 20.0 16.0 mAde 2.00000 24.93750 49.87500 74.87500 99.93750 74.93750 49.87500 24.87500 2.06250 183 1E12N056B 7/14105 AF 4.0 20.0 16.0 mAde 2.06250 24.93750 49.93750 74.93750 100.18750 74.93750 49.93750 24.93750 2.06250 184 1E12N056B 7/14/05 AL 4.0 20.0 16.0 mAde 2.06250 24.93750 49.93750 74.93750 100.18750 74.93750 49.93750 24.93750 2.06250 185 1E12N056B 10/22/03 AF 4.0 20.0 16.0 mAde 1.87500 24.50000 49.87500 74.12500 99.18750 74.12500 49.25000 24.50000 1.87500 186 1E12N056B 10/22/03 AL 4.0 20.0 16.0 mAde 2.00000 24.93750 49.81250 74.81250 100.06250 74.81250 49.81250 24.93750 2.00000 187 1E12N056B 4/23/02 AF 4.0 20.0 16.0 mAde 2.12500 25.18750 50.31250 75.50000 100.62500 75.50000 50.31250 25.43750 2.25000

DRIFT ANALYSIS ENGINEERING DEPARTMENT GRAND GULF NUCLEAR STATION Rosemount Range Codes 5 - 8 Gage Pressure Transmitters Data Conversion JC-Q1111-09019 Rev. 0 Page 81 of 134 IDENTIFYING INFORMATION RANGE VALUES AF/AL CONVERTED TO % SPAN (AFAL-Min)*100%/Span Seq.

Tag 10 Span 1

2 3

4 5

6 7

8 9

10 Date AF/AL Min Max (Max-Min)

Units (0% Up)

(25% Up)

(50% Up)

(75% Up)

(100% Up)

(75% On)

(50% On)

(25% On)

(0% On) 188 1E12N056B 4/23/02 AL 4.0 20.0 16.0 mAde 2.00000 25.06250 49.87500 74.87500 100.06250 74.93750 49.93750 25.00000 2.00000 189 1E12N056B 12/6/00 AF 4.0 20.0 16.0 mAde 2.18750 25.06250 50.00000 74.81250 100.06250 74.87500 50.06250 25.06250 2.18750 190 1E12N056B 1216/00 AL 4.0 20.0 16.0 mAde 2.18750 25.06250 50.00000 74.81250 100.06250 74.87500 50.06250 25.06250 2.18750 191 1E12N056B 5/26/99 AF 4.0 20.0 16.0 mAde 2.14375 25.14375 50.15000 75.16250 100.15625 75.13750 50.13750 25.02500 2.24375 192 1E12N056B 5/26/99 AL 4.0 20.0 16.0 mAde 2.14375 25.14375 50.15000 75.16250 100.15625 75.13750 50.13750 25.02500 2.24375 193 1E12N056B 10/16/97 AF 4.0 20.0 16.0 mAde 2.18750 25.25000 50.37500 75.56250 100.93750 75.56250 50.43750 25.37500 2.18750 194 1E12N056B 10/16/97 AL 4.0 20.0 16.0 mAde 2.18750 24.93750 49.87500 74.93750 100.25000 75.00000 49.81250 24.93750 2.18750 195 1E12N056C 4/6/10 AF 4.0 20.0 16.0 mAde 0.00000 24.56250 49.56250 74.56250 99.56250 74.50000 49.56250 24.50000

-0.06250 196 1E12N056C 4/6/10 AL 4.0 20.0 16.0 mAde 0.12500 24.87500 49.93750 75.00000 100.12500 75.00000 49.93750 24.87500 0.12500 197 1E12N056C 7/8/08 AF 4.0 20.0 16.0 mAde 0.31250 25.00000 50.00000 75.00000 100.12500 75.00000 50.00000 25.00000 0.31250 198 1E12N056C 7/8/08 AL 4.0 20.0 16.0 mAde 0.31250 25.00000 50.00000 75.00000 100.12500 75.00000 50.00000 25.00000 0.31250 199 1E12N056C 1/10/07 AF 4.0 20.0 16.0 mAde 0.37500 25.00000 50.00000 75.00000 100.00000 75.00000 50.06250 25.00000 0.31250 200 1E12N056C 1/10/07 AL 4.0 20.0 16.0 mAde 0.37500 25.00000 50.00000 75.00000 100.00000 75.00000 50.06250 25.00000 0.31250 201 1E12N056C 6/29/05 AF 4.0 20.0 16.0 mAde 0.31250 25.00000 49.81250 74.68750 99.62500 74.68750 49.75000 24.87500 0.31250 202 1E12N056C 6/29/05 AL 4.0 20.0 16.0 mAde 0.31250 24.93750 49.93750 74.81250 99.93750 74.81250 49.93750 24.93750 0.31250 203 1E12N056C 10/22/03 AF 4.0 20.0 16.0 mAde 0.31250 25.00000 49.93750 74.87500 99.87500 74.87500 49.93750 25.00000 0.31250 204 1E12N056C 10/22/03 AL 4.0 20.0 16.0 mAde 0.31250 25.00000 49.93750 74.87500 99.87500 74.87500 49.93750 25.00000 0.31250 205 1E12N056C 7/3/02 AF 4.0 20.0 16.0 mAde 0.25000 24.87500 49.87500 74.81250 99.81250 74.81250 49.87500 25.00000 0.25000 206 1E12N056C 7/3/02 AL 4.0 20.0 16.0 mAde 0.25000 24.87500 49.87500 74.81250 99.81250 74.81250 49.87500 25.00000 0.25000 207 1E12N056C 12/6/00 AF 4.0 20.0 16.0 mAde 0.31250 24.93750 49.68750 74.75000 99.68750 74.68750 49.81250 25.00000 0.31250 208 1E12N056C 1216/00 AL 4.0 20.0 16.0 mAde 0.37500 25.06250 49.93750 74.93750 99.93750 74.93750 50.00000 25.06250 0.37500 209 1E12N056C 5/26/99 AF 4.0 20.0 16.0 mAde 0.08750 25.02500 50.19375 74.90625 99.94375 75.06875 50.23125 25.11875 0.21875 210 1E12N056C 5/26/99 AL 4.0 20.0 16.0 mAde 0.08750 25.02500 50.19375 74.90625 99.94375 75.06875 50.23125 25.11875 0.21875 211 1E12N056C 10/16/97 AF 4.0 20.0 16.0 mAde 0.31250 25.06250 49.81250 74.81250 99.87500 74.81250 49.81250 24.93750 0.31250 212 1E12N056C 10/16/97 AL 4.0 20.0 16.0 mAde 0.31250 25.06250 49.81250 74.81250 99.87500 74.81250 49.81250 24.93750 0.31250 213 1E12N057 219/10 AF 4.0 20.0 16.0 mAde

-0.06250 24.93750 50.00000 74.93750 99.93750 74.93750 50.00000 25.00000

-0.06250 214 1E12N057 219/10 AL 4.0 20.0 16.0 mAde

-0.06250 24.93750 50.00000 74.93750 99.93750 74.93750 50.00000 25.00000

-0.06250 215 1E12N057 4/25/08 AF 4.0 20.0 16.0 mAde

-0.06250 25.00000 50.00000 75.00000 100.00000 75.06250 50.06250 25.06250 0.00000 216 1E12N057 4/25/08 AL 4.0 20.0 16.0 mAde

-0.06250 25.00000 50.00000 75.00000 100.00000 75.06250 50.06250 25.06250 0.00000 217 1E12N057 7/19/06 AF 4.0 20.0 16.0 mAde 0.00000 25.00000 49.93750 74.93750 99.93750 75.00000 49.93750 25.00000 0.00000 218 1E12N057 7/19/06 AL 4.0 20.0 16.0 mAde 0.00000 25.00000 49.93750 74.93750 99.93750 75.00000 49.93750 25.00000 0.00000 219 1E12N057 1120/05 AF 4.0 20.0 16.0 mAde 0.00000 25.00000 50.00000 75.00000 100.00000 75.06250 50.12500 25.06250 0.00000 220 1E12N057 1120/05 AL 4.0 20.0 16.0 mAde 0.00000 25.00000 50.00000 75.00000 100.00000 75.06250 50.12500 25.06250 0.00000 221 1E12N057 8/8/03 AF 4.0 20.0 16.0 mAde 0.00000 24.87500 49.87500 74.87500 99.93750 75.00000 50.00000 24.93750

-0.06250 222 1E12N057 8/8/03 AL 4.0 20.0 16.0 mAde 0.00000 24.87500 49.87500 74.87500 99.93750 75.00000 50.00000 24.93750

-0.06250 223 1E12N057 2/20/02 AF 4.0 20.0 16.0 mAde 0.00000 24.93750 50.00000 74.93750 100.00000 74.93750 50.12500 25.00000 0.00000 224 1E12N057 2/20/02 AL 4.0 20.0 16.0 mAde 0.00000 24.93750 50.00000 74.93750 100.00000 74.93750 50.12500 25.00000 0.00000 225 1E12N057 218/01 AF 4.0 20.0 16.0 mAde

-0.18750 24.75000 49.75000 74.68750 99.62500 74.81250 49.75000 24.81250

-0.18750 226 1E12N057 218/01 AL 4.0 20.0 16.0 mAde 0.00000 24.93750 49.93750 74.93750 99.93750 75.00000 50.00000 25.00000 0.00000 227 1E12N057 8/1/99 AF 4.0 20.0 16.0 mAde

-0.06250 24.93750 49.87500 74.93750 99.87500 75.00000 50.06250 25.00000 0.00000 228 1E12N057 8/1/99 AL 4.0 20.0 16.0 mAde

-0.06250 24.93750 49.87500 74.93750 99.87500 75.00000 50.06250 25.00000 0.00000 229 1E12N057 1/27/98 AF 4.0 20.0 16.0 mAde 0.15625 25.43750 50.56250 75.56250 100.44375 75.46875 50.58125 25.56875 0.34375 230 1E12N057 1/27/98 AL 4.0 20.0 16.0 mAde 0.08750 25.02500 50.08125 75.10000 100.01250 75.12500 50.14375 25.05000

-0.01250 231 1E12N058A 7/12110 AF 4.0 20.0 16.0 mAde

-0.06250 24.87500 49.87500 74.93750 99.93750 75.00000 49.93750 24.93750

-0.06250 232 1E12N058A 7/12/10 AL 4.0 20.0 16.0 mAde

-0.06250 24.87500 49.87500 74.93750 99.93750 75.00000 49.93750 24.93750

-0.06250 233 1E12N058A 9/10/08 AF 4.0 20.0 16.0 mAde 0.00000 25.00000 50.00000 75.00000 100.00000 75.00000 50.12500 25.06250 0.00000 234 1E12N058A 9/10/08 AL 4.0 20.0 16.0 mAde 0.00000 25.00000 50.00000 75.00000 100.00000 75.00000 50.12500 25.06250 0.00000

DRIFT ANALYSIS ENGINEERING DEPARTMENT GRAND GULF NUCLEAR STATION Rosemount Range Codes 5 - 8 Gage Pressure Transmitters Data Conversion JC-Q1111-09019 Rev. 0 Page 82 of 134 IDENTIFYING INFORMATION RANGE VALUES AF/AL CONVERTED TO % SPAN (AFAL-Min)*100%/Span Seq.

Span 1

2 3

4 5

6 7

8 9

10 Tag 10 Date AF/AL Min Max (Max-Min)

Units (0% Up)

(25% Up)

(50% Up)

(75% Up)

(100% Up)

(75% On)

(50% On)

(25% On)

(0% On) 235 1E12N058A 1/16/07 AF 4.0 20.0 16.0 mAde

-0.06250 25.00000 49.93750 75.00000 100.00000 75.00000 50.00000 25.06250

-0.06250 236 1E12N058A 1/16/07 AL 4.0 20.0 16.0 mAde

-0.06250 25.00000 49.93750 75.00000 100.00000 75.00000 50.00000 25.06250

-0.06250 237 1E12N058A 7/22/05 AF 4.0 20.0 16.0 mAde

-0.06250 25.00000 50.00000 75.00000 100.00000 74.93750 50.00000 24.93750 0.00000 238 1E12N058A 7/22/05 AL 4.0 20.0 16.0 mAde

-0.06250 25.00000 50.00000 75.00000 100.00000 74.93750 50.00000 24.93750 0.00000 239 1E12N058A 1/9/04 AF 4.0 20.0 16.0 mAde 0.06250 24.93750 49.81250 74.75000 99.62500 74.81250 49.87500 24.93750 0.06250 240 1E12N058A 1/9/04 AL 4.0 20.0 16.0 mAde 0.00000 25.00000 50.00000 74.93750 100.00000 74.93750 50.00000 25.00000 0.00000 241 1E12N058A 9/9/02 AF 4.0 20.0 16.0 mAde 0.12500 25.25000 50.18750 75.18750 EXC 75.18750 50.18750 25.25000 0.12500 242 1E12N058A 9/9/02 AL 4.0 20.0 16.0 mAde 0.06250 25.06250 50.00000 75.06250 100.00000 75.06250 49.93750 25.12500 0.06250 243 1E12N058A 1/23/01 AF 4.0 20.0 16.0 mAde 0.18750 25.12500 50.12500 75.12500 100.18750 75.12500 50.18750 25.18750 0.18750 244 1E12N058A 1/23/01 AL 4.0 20.0 16.0 mAde 0.18750 25.12500 50.12500 75.12500 100.18750 75.12500 50.18750 25.18750 0.18750 245 1E12N058A 9/22/99 AF 4.0 20.0 16.0 mAde

-0.43750 24.81250 49.81250 74.81250 99.75000 74.81250 49.87500 24.81250

-0.31250 246 1E12N058A 9/22/99 AL 4.0 20.0 16.0 mAde 0.06250 25.12500 50.06250 75.12500 100.00000 75.06250 50.12500 25.12500 0.06250 247 1E12N058A 1/28/98 AF 4.0 20.0 16.0 mAde

-0.12500 24.87500 49.87500 75.00000 100.00000 74.93750 50.00000 24.93750 0.00000 248 1E12N058A 1/28/98 AL 4.0 20.0 16.0 mAde

-0.12500 24.87500 49.87500 75.00000 100.00000 74.93750 50.00000 24.93750 0.00000 249 1E12N058B 2119/10 AF 4.0 20.0 16.0 mAde 0.00000 24.81250 49.75000 74.81250 99.93750 74.87500 49.81250 24.75000 0.00000 250 1E12N058B 2119/10 AL 4.0 20.0 16.0 mAde 0.00000 24.81250 49.75000 74.81250 99.93750 74.87500 49.81250 24.75000 0.00000 251 1E12N058B 7/10/08 AF 4.0 20.0 16.0 mAde 0.06250 25.12500 50.06250 75.06250 100.12500 75.12500 50.18750 25.25000 0.31250 252 1E12N058B 7/10/08 AL 4.0 20.0 16.0 mAde 0.00000 24.93750 49.93750 74.93750 100.00000 75.00000 50.00000 25.00000 0.00000 253 1E12N058B 1/10/07 AF 4.0 20.0 16.0 mAde 0.18750 25.12500 50.12500 75.06250 100.06250 75.12500 50.12500 25.12500 0.18750 254 1E12N058B 1/10/07 AL 4.0 20.0 16.0 mAde 0.18750 25.12500 50.12500 75.06250 100.06250 75.12500 50.12500 25.12500 0.18750 255 1E12N058B 6/29/05 AF 4.0 20.0 16.0 mAde 0.18750 25.00000 49.93750 74.93750 99.93750 75.00000 50.00000 25.06250 0.18750 256 1E12N058B 6/29/05 AL 4.0 20.0 16.0 mAde 0.18750 25.00000 49.93750 74.93750 99.93750 75.00000 50.00000 25.06250 0.18750 257 1E12N058B 1/14/04 AF 4.0 20.0 16.0 mAde 0.06250 25.00000 50.00000 75.00000 100.00000 75.12500 50.18750 25.18750 0.18750 258 1E12N058B 1/14/04 AL 4.0 20.0 16.0 mAde 0.06250 25.00000 50.00000 75.00000 100.00000 75.12500 50.18750 25.18750 0.18750 259 1E12N058B 7/18/02 AF 4.0 20.0 16.0 mAde 0.00000 24.93750 49.93750 75.00000 99.93750 74.93750 50.06250 25.06250 0.06250 260 1E12N058B 7/18/02 AL 4.0 20.0 16.0 mAde 0.00000 24.93750 49.93750 75.00000 99.93750 74.93750 50.06250 25.06250 0.06250 261 1E12N058B 1/29/01 AF 4.0 20.0 16.0 mAde 0.18750 25.00000 49.87500 74.87500 100.12500 75.00000 49.93750 25.06250 0.18750 262 1E12N058B 1/29/01 AL 4.0 20.0 16.0 mAde 0.18750 25.00000 49.87500 74.87500 100.12500 75.00000 49.93750 25.06250 0.18750 263 1E12N058B 8/19/99 AF 4.0 20.0 16.0 mAde 0.21250 25.17500 50.16250 75.10625 100.10000 75.11250 50.15000 25.16250 0.18750 264 1E12N058B 8119/99 AL 4.0 20.0 16.0 mAde 0.21250 25.17500 50.16250 75.10625 100.10000 75.11250 50.15000 25.16250 0.18750 265 1E12N058B 1/5/98 AF 4.0 20.0 16.0 mAde

-0.06250 25.12500 50.12500 75.43750 100.37500 75.50000 50.37500 25.12500 0.18750 266 1E12N058B 1/5/98 AL 4.0 20.0 16.0 mAde 0.00000 25.00000 50.00000 75.00000 99.93750 75.06250 50.06250 25.06250 0.06250 267 1E12N058C 2/16/10 AF 4.0 20.0 16.0 mAde

-0.25000 24.75000 49.68750 74.75000 99.68750 74.75000 49.81250 24.81250

-0.18750 268 1E12N058C 2/16/10 AL 4.0 20.0 16.0 mAde 0.12500 25.12500 50.06250 75.00000 100.00000 75.06250 50.12500 25.12500 0.12500 269 1E12N058C 6/24/08 AF 4.0 20.0 16.0 mAde 0.00000 24.87500 49.81250 74.75000 99.75000 74.81250 49.81250 24.87500 0.00000 270 1E12N058C 6/24/08 AL 4.0 20.0 16.0 mAde 0.00000 24.93750 49.87500 74.87500 99.93750 74.87500 49.93750 25.06250 0.00000 271 1E12N058C 12/2/06 AF 4.0 20.0 16.0 mAde 0.18750 25.00000 49.93750 75.00000 100.00000 75.00000 50.06250 25.12500 0.25000 272 1E12N058C 12/2/06 AL 4.0 20.0 16.0 mAde 0.18750 25.00000 49.93750 75.00000 100.00000 75.00000 50.06250 25.12500 0.25000 273 1E12N058C 5/19/05 AF 4.0 20.0 16.0 mAde 0.12500 25.00000 49.87500 74.87500 99.93750 75.00000 50.06250 25.06250 0.12500 274 1E12N058C 5/19/05 AL 4.0 20.0 16.0 mAde 0.12500 25.00000 49.87500 74.87500 99.93750 75.00000 50.06250 25.06250 0.12500 275 1E12N058C 10/23/03 AF 4.0 20.0 16.0 mAde 0.06250 24.93750 49.87500 74.81250 99.87500 75.00000 50.00000 25.06250 0.12500 276 1E12N058C 10/23/03 AL 4.0 20.0 16.0 mAde 0.06250 24.93750 49.87500 74.81250 99.87500 75.00000 50.00000 25.06250 0.12500 277 1E12N058C 7/18/02 AF 4.0 20.0 16.0 mAde

-0.25000 24.75000 49.75000 74.75000 99.75000 74.75000 49.75000 24.75000

-0.18750 278 1E12N058C 7/18/02 AL 4.0 20.0 16.0 mAde 0.06250 25.00000 49.93750 74.93750 99.93750 74.93750 49.93750 24.93750 0.00000 279 1E12N058C 1/29/01 AF 4.0 20.0 16.0 mAde

-0.12500 24.87500 49.81250 74.93750 100.12500 75.00000 50.06250 25.00000

-0.06250 280 1E12N058C 1/29/01 AL 4.0 20.0 16.0 mAde

-0.12500 24.87500 49.81250 74.93750 100.12500 75.00000 50.06250 25.00000

-0.06250 281 1E12N058C 9/2/99 AF 4.0 20.0 16.0 mAde 0.25000 25.37500 50.50000 75.62500 100.62500 75.50000 50.75000 25.31250 0.12500

DRIFT ANALYSIS ENGINEERING DEPARTMENT GRAND GULF NUCLEAR STATION Rosemount Range Codes 5 - 8 Gage Pressure Transmitters Data Conversion JC-Q1111-09019 Rev. 0 Page 83 of 134 IDENTIFYING INFORMATION RANGE VALUES AF/AL CONVERTED TO % SPAN (AFAL-Min)*100%/Span Seq.

Span 1

2 3

4 5

6 7

8 9

10 Tag 10 Date AF/AL Min Max (Max-Min)

Units (0% Up)

(25% Up)

(50% Up)

(75% Up)

(100% Up)

(75%

On)

(50% On)

(25% On)

(0% On) 282 1E12N058C 9/2/99 AL 4.0 20.0 16.0 mAde

-0.12500 25.06250 50.06250 75.06250 100.18750 75.12500 50.18750 25.06250

-0.06250 283 1E12N058C 2121/98 AF 4.0 20.0 16.0 mAde

-0.18750 24.93750 49.50000 74.56250 99.62500 74.75000 49.62500 24.87500

-0.18750 284 1E12N058C 2121/98 AL 4.0 20.0 16.0 mAde 0.06250 24.87500 49.87500 75.00000 100.00000 75.00000 49.87500 24.87500 0.06250 285 1E21N050 8/27/10 AF 4.0 20.0 16.0 mAde

-0.06250 24.93750 49.87500 74.93750 99.93750 74.93750 49.93750 25.00000

-0.06250 286 1E21N050 8/27/10 AL 4.0 20.0 16.0 mAde

-0.06250 24.93750 49.87500 74.93750 99.93750 74.93750 49.93750 25.00000

-0.06250 287 1E21N050 11/20/08 AF 4.0 20.0 16.0 mAde

-0.06250 24.87500 49.87500 74.93750 99.87500 74.93750 50.00000 25.06250 0.06250 288 1E21N050 11/20/08 AL 4.0 20.0 16.0 mAde

-0.06250 24.87500 49.87500 74.93750 99.87500 74.93750 50.00000 25.06250 0.06250 289 1E21N050 5/11/07 AF 4.0 20.0 16.0 mAde

-0.12500 24.81250 49.81250 74.81250 99.87500 74.87500 50.00000 24.87500

-0.06250 290 1E21N050 5/11/07 AL 4.0 20.0 16.0 mAde

-0.12500 24.81250 49.81250 74.81250 99.87500 74.87500 50.00000 24.87500

-0.06250 291 1E21N050 7118/05 AF 4.0 20.0 16.0 mAde

-0.06250 24.87500 49.93750 75.00000 100.00000 75.00000 49.93750 24.93750 0.06250 292 1E21N050 7118/05 AL 4.0 20.0 16.0 mAde

-0.06250 24.87500 49.93750 75.00000 100.00000 75.00000 49.93750 24.93750 0.06250 293 1E21N050 10/14/03 AF 4.0 20.0 16.0 mAde

-0.06250 24.93750 49.87500 74.93750 99.93750 75.00000 50.00000 24.93750 0.00000 294 1E21N050 10/14/03 AL 4.0 20.0 16.0 mAde

-0.06250 24.93750 49.87500 74.93750 99.93750 75.00000 50.00000 24.93750 0.00000 295 1E21N050 4/18/02 AF 4.0 20.0 16.0 mAde

-0.18750 24.68750 49.68750 74.75000 99.81250 74.87500 49.75000 24.81250

-0.25000 296 1E21N050 4/18/02 AL 4.0 20.0 16.0 mAde 0.00000 25.00000 49.87500 74.93750 100.12500 75.00000 49.93750 24.93750 0.00000 297 1E21N050 10/16/00 AF 4.0 20.0 16.0 mAde

-0.06250 24.93750 49.87500 74.87500 100.00000 74.93750 49.93750 24.93750 0.00000 298 1E21N050 10/16/00 AL 4.0 20.0 16.0 mAde

-0.06250 24.93750 49.87500 74.87500 100.00000 74.93750 49.93750 24.93750 0.00000 299 1E21N050 4/11/99 AF 4.0 20.0 16.0 mAde

-0.14375 24.78750 49.84375 74.93125 100.02500 75.01875 49.95625 24.91875 0.00000 300 1E21N050 4/11/99 AL 4.0 20.0 16.0 mAde

-0.14375 24.78750 49.84375 74.93125 100.02500 75.01875 49.95625 24.91875 0.00000 301 1E21N050 8/30/97 AF 4.0 20.0 16.0 mAde

-0.06250 25.00000 50.00000 74.87500 99.93750 75.00000 50.00000 25.00000 0.00000 302 1E21N050 8/30/97 AL 4.0 20.0 16.0 mAde

-0.06250 25.00000 50.00000 74.87500 99.93750 75.00000 50.00000 25.00000 0.00000 303 1E21N052 218/10 AF 4.0 20.0 16.0 mAde 0.25000 25.00000 50.06250 75.00000 100.00000 75.06250 50.06250 25.00000 0.25000 304 1E21N052 218/10 AL 4.0 20.0 16.0 mAde 0.25000 25.00000 50.06250 75.00000 100.00000 75.06250 50.06250 25.00000 0.25000 305 1E21N052 5/22/08 AF 4.0 20.0 16.0 mAde

-0.06250 24.50000 49.50000 74.37500 99.37500 74.37500 49.43750 24.43750

-0.06250 306 1E21N052 5/22108 AL 4.0 20.0 16.0 mAde 0.37500 25.00000 49.93750 74.93750 99.93750 74.93750 49.93750 25.00000 0.37500 307 1E21N052 11/10/06 AF 4.0 20.0 16.0 mAde 0.31250 25.00000 49.87500 74.87500 99.87500 74.87500 49.87500 24.93750 0.31250 308 1E21N052 11/10/06 AL 4.0 20.0 16.0 mAde 0.31250 25.00000 49.87500 74.87500 99.87500 74.87500 49.87500 24.93750 0.31250 309 1E21N052 4/12/05 AF 4.0 20.0 16.0 mAde

-0.37500 24.56250 49.56250 74.62500 99.62500 74.56250 49.56250 24.56250

-0.25000 310 1E21N052 4/12/05 AL 4.0 20.0 16.0 mAde 0.25000 24.93750 50.00000 75.00000 99.93750 75.00000 49.93750 25.00000 0.25000 311 1E21N052 6/25/03 AF 4.0 20.0 16.0 mAde 0.56250 25.75000 50.75000 76.43750 101.93750 76.43750 50.75000 25.75000 0.62500 312 1E21N052 6/25/03 AL 4.0 20.0 16.0 mAde 0.06250 24.87500 49.87500 74.93750 99.93750 74.93750 49.87500 24.87500 0.06250 313 1E21N052 1/9/02 AF 4.0 20.0 16.0 mAde 0.43750 24.93750 49.43750 74.06250 98.50000 73.93750 49.37500 24.87500 0.56250 314 1E21N052 1/9/02 AL 4.0 20.0 16.0 mAde 0.43750 25.06250 50.00000 75.06250 100.06250 75.06250 50.06250 25.12500 0.43750 315 1E21N052 9/10/00 AF 4.0 20.0 16.0 mAde 0.00000 24.62500 49.56250 74.56250 99.56250 74.62500 49.62500 24.62500 0.00000 316 1E21N052 9/10/00 AL 4.0 20.0 16.0 mAde 0.31250 24.87500 49.87500 74.87500 99.87500 74.87500 49.93750 24.87500 0.31250 317 1E21N052 3/10/99 AF 4.0 20.0 16.0 mAde 0.31250 24.93750 49.87500 74.87500 99.93750 74.93750 49.93750 24.87500 0.37500 318 1E21N052 3/10/99 AL 4.0 20.0 16.0 mAde 0.31250 24.93750 49.87500 74.87500 99.93750 74.93750 49.93750 24.87500 0.37500 319 1E21N052 8/25/97 AF 4.0 20.0 16.0 mAde 0.25625 25.14375 50.10625 75.08750 100.04375 75.05625 50.12500 25.11875 0.32500 320 1E21N052 8/25/97 AL 4.0 20.0 16.0 mAde 0.25625 25.14375 50.10625 75.08750 100.04375 75.05625 50.12500 25.11875 0.32500 321 1E21N053 8/10/09 AF 4.0 20.0 16.0 mAde 0.18750 24.93750 49.93750 74.93750 99.93750 75.00000 50.00000 24.93750 0.25000 322 1E21N053 8/10/09 AL 4.0 20.0 16.0 mAde 0.18750 24.93750 49.93750 74.93750 99.93750 75.00000 50.00000 24.93750 0.25000 323 1E21N053 2/14/08 AF 4.0 20.0 16.0 mAde 0.31250 24.93750 50.00000 75.00000 100.00000 75.00000 50.06250 25.00000 0.31250 324 1E21N053 2/14/08 AL 4.0 20.0 16.0 mAde 0.31250 24.93750 50.00000 75.00000 100.00000 75.00000 50.06250 25.00000 0.31250 325 1E21N053 8/15/06 AF 4.0 20.0 16.0 mAde 0.18750 25.00000 50.00000 75.12500 99.93750 75.12500 50.00000 25.00000 0.18750 326 1E21N053 8/15/06 AL 4.0 20.0 16.0 mAde 0.18750 25.00000 50.00000 75.12500 99.93750 75.12500 50.00000 25.00000 0.18750 327 1E21N053 1/22/05 AF 4.0 20.0 16.0 mAde 0.12500 24.87500 50.00000 74.93750 100.12500 74.93750 50.00000 24.93750 0.12500 328 1E21N053 1/22/05 AL 4.0 20.0 16.0 mAde 0.12500 24.87500 50.00000 74.93750 100.12500 74.93750 50.00000 24.93750 0.12500

DRIFT ANALYSIS ENGINEERING DEPARTMENT GRAND GULF NUCLEAR STATION Rosemount Range Codes 5 - 8 Gage Pressure Transmitters Data Conversion JC-Q1111-09019 Rev. 0 Page 84 of 134 IDENTIFYING INFORMATION RANGE VALUES AF/AL CONVERTED TO % SPAN (AFAL-Min)*100%/Span Seq.

Tag 10 Date AF/AL Min Max Span 1

2 3

4 5

6 7

8 9

10 (Max-Min)

Units (0% Up)

(25% Up)

(50% Up)

(75% Up)

(100% Up)

(75% On)

(50% On)

(25% On)

(0% On) 329 1E21N053 7/22/03 AF 4.0 20.0 16.0 mAde 0.12500 25.25000 50.62500 76.00000 101.31250 76.06250 50.62500 25.25000 0.18750 330 1E21N053 7/22/03 AL 4.0 20.0 16.0 mAde 0.25000 25.00000 50.00000 75.06250 100.00000 75.06250 50.06250 25.00000 0.25000 331 1E21N053 1/10/02 AF 4.0 20.0 16.0 mAde 0.12500 25.18750 50.25000 75.12500 100.06250 75.18750 50.25000 25.25000 0.18750 332 1E21N053 1/10/02 AL 4.0 20.0 16.0 mAde 0.12500 25.18750 50.25000 75.12500 100.06250 75.18750 50.25000 25.25000 0.18750 333 1E21N053 9/10/00 AF 4.0 20.0 16.0 mAde

-0.12500 24.37500 49.37500 74.25000 99.18750 74.37500 49.31250 24.37500

-0.12500 334 1E21N053 9/10/00 AL 4.0 20.0 16.0 mAde 0.43750 25.06250 50.00000 75.00000 99.81250 75.00000 50.00000 25.06250 0.43750 335 1E21N053 3/11/99 AF 4.0 20.0 16.0 mAde 0.29375 25.00000 50.00000 75.06250 100.06250 75.12500 50.06250 25.00000 0.24375 336 1E21N053 3/11/99 AL 4.0 20.0 16.0 mAde 0.29375 25.00000 50.00000 75.06250 100.06250 75.12500 50.06250 25.00000 0.24375 337 1E21N053 8/25/97 AF 4.0 20.0 16.0 mAde 0.21250 25.11250 50.08750 75.01250 100.05000 74.96250 50.06250 24.99375 0.23750 338 1E21N053 8/25/97 AL 4.0 20.0 16.0 mAde 0.21250 25.11250 50.08750 75.01250 100.05000 74.96250 50.06250 24.99375 0.23750 339 1E21N054 9/24/10 AF 4.0 20.0 16.0 mAde 0.06250 24.87500 49.87500 74.87500 99.93750 74.93750 50.00000 25.00000 0.12500 340 1E21N054 9/24/10 AL 4.0 20.0 16.0 mAde 0.06250 24.87500 49.87500 74.87500 99.93750 74.93750 50.00000 25.00000 0.12500 341 1E21N054 11/20/08 AF 4.0 20.0 16.0 mAde 1.12500 25.43750 50.25000 75.25000 99.81250 75.25000 50.43750 25.56250 1.12500 342 1E21N054 11/20/08 AL 4.0 20.0 16.0 mAde 0.18750 24.81250 49.81250 74.93750 100.18750 75.18750 50.00000 24.87500 0.18750 343 1E21N054 5/7/07 AF 4.0 20.0 16.0 mAde 0.12500 24.93750 49.87500 74.87500 99.81250 75.00000 50.06250 25.06250 0.12500 344 1E21N054 517107 AL 4.0 20.0 16.0 mAde 0.12500 24.93750 49.87500 74.87500 99.81250 75.00000 50.06250 25.06250 0.12500 345 1E21N054 811105 AF 4.0 20.0 16.0 mAde 0.12500 24.93750 49.87500 74.87500 99.87500 75.00000 50.06250 25.06250 0.18750 346 1E21N054 811105 AL 4.0 20.0 16.0 mAde 0.12500 24.93750 49.87500 74.87500 99.87500 75.00000 50.06250 25.06250 0.18750 347 1E21N054 12/9/03 AF 4.0 20.0 16.0 mAde 0.12500 24.81250 49.93750 75.06250 99.93750 74.93750 50.00000 24.93750 0.18750 348 1E21N054 12/9/03 AL 4.0 20.0 16.0 mAde 0.12500 24.81250 49.93750 75.06250 99.93750 74.93750 50.00000 24.93750 0.18750 349 1E21N054 7/11/02 AF 4.0 20.0 16.0 mAde 0.18750 25.00000 50.00000 75.00000 100.06250 75.00000 49.93750 24.93750 0.18750 350 1E21N054 7/11/02 AL 4.0 20.0 16.0 mAde 0.18750 25.00000 50.00000 75.00000 100.06250 75.00000 49.93750 24.93750 0.18750 351 1E21N054 1/23/01 AF 4.0 20.0 16.0 mAde 0.12500 24.93750 49.93750 74.93750 99.93750 74.93750 50.00000 25.00000 0.12500 352 1E21N054 1/23/01 AL 4.0 20.0 16.0 mAde 0.12500 24.93750 49.93750 74.93750 99.93750 74.93750 50.00000 25.00000 0.12500 353 1E21N054 7/12/99 AF 4.0 20.0 16.0 mAde 0.21250 25.00000 49.98125 74.88750 99.89375 75.00000 50.08750 25.06875 0.21875 354 1E21N054 7/12/99 AL 4.0 20.0 16.0 mAde 0.21250 25.00000 49.98125 74.88750 99.89375 75.00000 50.08750 25.06875 0.21875 355 1E21N054 1/15/98 AF 4.0 20.0 16.0 mAde 0.12500 25.00000 49.87500 75.00000 100.06250 75.12500 50.06250 25.06250 0.12500 356 1E21N054 1/15/98 AL 4.0 20.0 16.0 mAde 0.12500 25.00000 49.87500 75.00000 100.06250 75.12500 50.06250 25.06250 0.12500 357 1E22N050 3119/10 AF 4.0 20.0 16.0 mAde 11.56250 25.50000 49.43750 75.43750 99.43750 75.43750 49.43750 25.43750 11.50000 358 1E22N050 3/19/10 AL 4.0 20.0 16.0 mAde 11.75000 25.75000 49.75000 75.75000 99.75000 75.75000 49.75000 25.75000 11.75000 359 1E22N050 6/27/08 AF 4.0 20.0 16.0 mAde EXC 25.62500 49.62500 75.68750 99.68750 75.68750 49.68750 25.62500 EXC 360 1E22N050 6/27/08 AL 4.0 20.0 16.0 mAde EXC 25.62500 49.62500 75.68750 99.68750 75.68750 49.68750 25.62500 EXC 361 1E22N050 11/15/06 AF 4.0 20.0 16.0 mAde EXC 25.68750 49.56250 75.50000 99.37500 75.50000 49.56250 25.68750 EXC 362 1E22N050 11/15/06 AL 4.0 20.0 16.0 mAde EXC 25.75000 49.75000 75.75000 99.75000 75.75000 49.75000 25.75000 EXC 363 1E22N050 6/3/05 AF 4.0 20.0 16.0 mAde EXC 24.12500 49.12500 74.75000 99.12500 74.93750 48.25000 24.50000 EXC 364 1E22N050 6/3/05 AL 4.0 20.0 16.0 mAde EXC 25.75000 49.62500 75.62500 99.68750 75.68750 49.68750 25.87500 EXC 365 1E22N050 9/26/03 AF 4.0 20.0 16.0 mAde EXC 24.75000 48.93750 75.00000 98.93750 75.00000 49.00000 24.87500 EXC 366 1E22N050 9/26/03 AL 4.0 20.0 16.0 mAde EXC 25.68750 49.56250 75.75000 99.81250 75.87500 49.75000 25.62500 EXC 367 1E22N050 4/12102 AF 4.0 20.0 16.0 mAde EXC 25.56250 49.56250 75.50000 99.56250 75.56250 49.62500 25.62500 EXC 368 1E22N050 4/12/02 AL 4.0 20.0 16.0 mAde EXC 25.56250 49.56250 75.50000 99.56250 75.56250 49.62500 25.62500 EXC 369 1E22N050 11/24/00 AF 4.0 20.0 16.0 mAde EXC 26.31250 50.06250 75.93750 99.81250 75.81250 49.75000 25.87500 EXC 370 1E22N05O 11/24/00 AL 4.0 20.0 16.0 mAde EXC 26.00000 49.87500 75.75000 99.68750 75.75000 49.56250 25.93750 EXC 371 1E22N050 4/2/99 AF 4.0 20.0 16.0 mAde EXC 25.68750 49.68750 75.68750 99.56250 75.68750 49.68750 25.68750 EXC 372 1E22N050 4/2/99 AL 4.0 20.0 16.0 mAde EXC 25.68750 49.68750 75.68750 99.56250 75.68750 49.68750 25.68750 EXC 373 1E22N050 9/5/97 AF 4.0 20.0 16.0 mAde EXC 25.53750 49.87500 75.84375 99.88750 75.60000 49.70000 25.83750 EXC 374 1E22N050 9/5/97 AL 4.0 20.0 16.0 mAde EXC 25.53750 49.87500 75.84375 99.88750 75.60000 49.70000 25.83750 EXC

DRIFT ANALYSIS ENGINEERING DEPARTMENT GRAND GULF NUCLEAR STATION Rosemount Range Codes 5 - 8 Gage Pressure Transmitters Data Conversion JC-Q1111-09019 Rev. 0 Page 85 of 134 IDENTIFYING INFORMATION RANGE VALUES AF/AL CONVERTED TO % SPAN

{AFAL-Min)*100%/Span Seq.

Tag ID Date AF/AL Min Max Span Units 1

2 3

4 5

6 7

8 9

ID (Max-Min)

(O%Up)

(25% Up)

(50% Up)

(75% Up)

(100% Up)

(75% Dn)

(50% Dn)

(25% Dn)

(O%Dn) 375 1E22N054C 4/2/10 AF 4.0 20.0 16.0 mAde 0.43750 24.68750 49.87500 74.93750 99.93750 74.93750 49.87500 24.68750 0.43750 376 1E22N054C 4/2/10 AL 4.0 20.0 16.0 mAde 0.37500 24.56250 49.62500 74.75000 99.81250 74.75000 49.62500 24.56250 0.37500 377 1E22N054C 5/30/08 AF 4.0 20.0 16.0 mAde 0.56250 24.68750 49.81250 74.93750 100.06250 74.93750 49.81250 24.68750 0.56250 378 1E22N054C 5/30/08 AL 4.0 20.0 16.0 mAde 0.37500 24.56250 49.68750 74.81250 99.81250 74.81250 49.75000 24.56250 0.37500 379 1E22N054C 1/12/07 AF 4.0 20.0 16.0 mAde EXC EXC EXC EXC EXC EXC EXC EXC EXC 380 1E22N054C 1/12107 AL 4.0 20.0 16.0 mAde 0.43750 24.50000 49.68750 74.81250 99.87500 74.81250 49.68750 24.56250 0.43750 381 1E22N054G 11/20/09 AF 4.0 20.0 16.0 mAde 0.37500 24.50000 49.62500 74.81250 99.93750 74.87500 49.75000 24.56250 0.43750 382 1E22N054G 11/20/09 AL 4.0 20.0 16.0 mAde 0.37500 24.50000 49.62500 74.81250 99.93750 74.87500 49.75000 24.56250 0.43750 383 1E22N054G 5/30/08 AF 4.0 20.0 16.0 mAde 0.37500 24.37500 49.50000 74.62500 99.75000 74.62500 49.50000 24.43750 0.37500 384 1E22N054G 5/30/08 AL 4.0 20.0 16.0 mAde 0.31250 24.43750 49.62500 74.75000 99.81250 74.68750 49.62500 24.43750 0.31250 385 1E22N054G 10/20/06 AF 4.0 20.0 16.0 mAde EXC EXC EXC EXC EXC EXC EXC EXC EXC 386 1E22N054G 10/20/06 AL 4.0 20.0 16.0 mAde 0.37500 24.37500 49.50000 74.62500 99.81250 74.62500 49.50000 24.37500 0.37500 387 1E31N085A 5/12/10 AF 4.0 20.0 16.0 mAde 0.12500 24.93750 49.87500 74.87500 100.00000 74.93750 49.87500 24.93750 0.12500 388 1E31N085A 5/12/10 AL 4.0 20.0 16.0 mAde 0.12500 24.93750 49.87500 74.87500 100.00000 74.93750 49.87500 24.93750 0.12500 389 1E31N085A 9/30/08 AF 4.0 20.0 16.0 mAde

-0.18750 24.75000 49.62500 74.68750 99.81250 74.68750 49.62500 24.75000

-0.18750 390 1E31N085A 9/30/08 AL 4.0 20.0 16.0 mAde 0.00000 24.87500 49.87500 74.87500 100.00000 74.87500 49.87500 24.93750 0.00000 391 1E31N085A 4/2/07 AF 4.0 20.0 16.0 mAde

-0.06250 24.93750 49.81250 74.81250 100.00000 74.87500 49.87500 24.93750 0.06250 392 1E31 N085A 4/2/07 AL 4.0 20.0 16.0 mAde

-0.06250 24.93750 49.81250 74.81250 100.00000 74.87500 49.87500 24.93750 0.06250 393 1E31N085A 9/28/05 AF 4.0 20.0 16.0 mAde 0.00000 24.75000 49.62500 74.56250 99.62500 74.56250 49.62500 24.81250 0.06250 394 1E31N085A 9/28/05 AL 4.0 20.0 16.0 mAde 0.06250 24.87500 49.87500 74.81250 100.00000 74.87500 49.87500 24.87500 0.06250 395 1E31N085A 3/5/04 AF 4.0 20.0 16.0 mAde

-0.25000 24.87500 49.87500 74.87500 100.12500 74.87500 49.87500 24.87500

-0.18750 396 1E31N085A 3/5/04 AL 4.0 20.0 16.0 mAde

-0.06250 24.87500 49.87500 74.81250 100.12500 74.81250 49.81250 24.81250

-0.06250 397 1E31N085A 9/23/02 AF 4.0 20.0 16.0 mAde

-0.12500 24.93750 49.87500 75.00000 100.25000 75.00000 49.93750 24.93750 0.18750 398 1E31N085A 9/23/02 AL 4.0 20.0 16.0 mAde

-0.12500 24.93750 49.87500 75.00000 100.25000 75.00000 49.93750 24.93750 0.18750 399 1E31N085A 4/24/01 AF 4.0 20.0 16.0 mAde 0.81250 25.87500 50.87500 76.00000 101.00000 76.06250 50.93750 25.93750 0.81250 400 1E31N085A 4/24/01 AL 4.0 20.0 16.0 mAde 0.00000 25.06250 50.06250 75.12500 100.12500 75.12500 50.12500 25.06250 0.06250 401 1E31N085A 11/4/99 AF 4.0 20.0 16.0 mAde

-1.31250 23.43750 48.25000 73.18750 98.25000 73.25000 48.18750 23.43750

-1.37500 402 1E31N085A 11/4/99 AL 4.0 20.0 16.0 mAde 0.06250 24.87500 49.87500 74.87500 100.06250 74.87500 49.87500 24.93750 0.06250 403 1E31N085A 4/24/98 AF 4.0 20.0 16.0 mAde 0.06250 25.00000 49.81250 74.88750 100.00000 74.88125 49.83125 24.92500

-0.18125 404 1E31N085A 4/24/98 AL 4.0 20.0 16.0 mAde 0.06250 25.00000 49.81250 74.88750 100.00000 74.88125 49.83125 24.92500

-0.18125 405 1E31N0858 5/4/10 AF 4.0 20.0 16.0 mAde

-0.31250 24.37500 49.25000 74.25000 99.56250 74.31250 49.25000 24.43750

-0.31250 406 1E31N0858 5/4/10 AL 4.0 20.0 16.0 mAde 0.12500 24.87500 49.81250 74.87500 100.18750 74.87500 49.81250 24.87500 0.12500 407 1E31N0858 9/30/08 AF 4.0 20.0 16.0 mAde 0.00000 24.81250 49.81250 74.87500 100.06250 74.87500 49.87500 25.00000 0.06250 408 1E31N0858 9/30/08 AL 4.0 20.0 16.0 mAde 0.00000 24.81250 49.81250 74.87500 100.06250 74.87500 49.87500 25.00000 0.06250 409 1E31N0858 4/1/07 AF 4.0 20.0 16.0 mAde 0.43750 25.43750 50.50000 75.50000 100.68750 75.31250 50.31250 25.37500 0.43750 410 1E31N0858 4/1/07 AL 4.0 20.0 16.0 mAde 0.12500 24.93750 49.87500 74.87500 100.12500 74.87500 49.87500 24.93750 0.12500 411 1E31N0858 9/27/05 AF 4.0 20.0 16.0 mAde 0.12500 24.81250 49.56250 74.43750 99.62500 74.50000 49.56250 24.81250 0.18750 412 1E31N0858 9/27/05 AL 4.0 20.0 16.0 mAde 0.18750 24.87500 49.87500 74.87500 100.12500 74.87500 49.87500 24.87500 0.18750 413 1E31N0858 3/4/04 AF 4.0 20.0 16.0 mAde 9.37500 36.25000 60.93750 85.43750 109.81250 85.93750 60.93750 35.93750 12.50000 414 1E31N0858 3/4/04 AL 4.0 20.0 16.0 mAde 0.18750 25.18750 49.81250 74.81250 100.12500 74.81250 49.81250 25.00000 0.12500 415 1E31N0858 9/23/02 AF 4.0 20.0 16.0 mAde

-0.12500 25.06250 50.31250 75.62500 101.25000 76.12500 50.50000 25.12500

-0.06250 416 1E31N0858 9/23/02 AL 4.0 20.0 16.0 mAde 0.06250 24.87500 49.81250 74.87500 100.06250 74.87500 49.87500 24.93750 0.06250 417 1E31N0858 4/19/01 AF 4.0 20.0 16.0 mAde 0.75000 25.37500 49.93750 74.62500 99.43750 74.62500 49.93750 25.37500 0.75000 418 1E31N0858 4/19/01 AL 4.0 20.0 16.0 mAde 0.06250 24.93750 49.87500 74.93750 100.00000 74.93750 49.87500 24.93750 0.06250 419 1E31N0858 11/17/99 AF 4.0 20.0 16.0 mAde

-0.43750 24.25000 48.93750 73.93750 98.93750 73.93750 49.00000 24.25000

-0.43750

DRIFT ANALYSIS ENGINEERING DEPARTMENT GRAND GULF NUCLEAR STATION Rosemount Range Codes 5 - 8 Gage Pressure Transmitters Data Conversion JC-Q1111-09019 Rev. 0 Page 86 of 134 IDENTIFYING INFORMATION RANGE VALUES AF/AL CONVERTED TO % SPAN (AFAL-Min)*100%/Span Seq.

Tag 10 Date AF/AL Min Max Span 1

2 3

4 5

6 7

8 9

10 (Max-Min)

Units (0% Up)

(25% Up)

(50% Up)

(75% Up)

(100% Up)

(75% On)

(50% On)

(25% On)

(0% On) 420 1E31N085B 11/17199 AL 4.0 20.0 16.0 mAde 0.12500 25.00000 49.93750 75.00000 100.12500 75.00000 49.93750 25.00000 0.12500 421 1E31N085B 4/24/98 AF 4.0 20.0 16.0 mAde 0.24375 24.91875 50.00625 74.94375 100.01250 74.87500 49.90625 25.00625 0.04375 422 1E31N085B 4/24/98 AL 4.0 20.0 16.0 mAde 0.24375 24.91875 50.00625 74.94375 100.01250 74.87500 49.90625 25.00625 0.04375 423 1E32N050 5/4/10 AF 4.0 20.0 16.0 mAde 0.00000 25.00000 49.93750 74.87500 100.00000 74.93750 50.00000 25.00000 0.00000 424 1E32N050 5/4/10 AL 4.0 20.0 16.0 mAde 0.00000 25.00000 49.93750 74.87500 100.00000 74.93750 50.00000 25.00000 0.00000 425 1E32N050 10/4/08 AF 4.0 20.0 16.0 mAde 0.18750 25.25000 50.18750 75.18750 100.25000 75.18750 50.25000 25.25000 0.18750 426 1E32N050 10/4/08 AL 4.0 20.0 16.0 mAde 0.00000 25.00000 50.00000 74.93750 100.00000 74.93750 50.00000 25.00000 0.00000 427 1E32N050 4/4/07 AF 4.0 20.0 16.0 mAde 0.25000 25.12500 50.06250 75.06250 100.06250 75.06250 50.06250 25.12500 0.25000 428 1E32N050 4/4107 AL 4.0 20.0 16.0 mAde 0.25000 25.12500 50.06250 75.06250 100.06250 75.06250 50.06250 25.12500 0.25000 429 1E32N050 9/29/05 AF 4.0 20.0 16.0 mAde

-0.12500 25.06250 49.93750 75.00000 99.93750 74.87500 49.87500 24.87500 0.00000 430 1E32N050 9/29/05 AL 4.0 20.0 16.0 mAde

-0.12500 25.06250 49.93750 75.00000 99.93750 74.87500 49.87500 24.87500 0.00000 431 1E32N050 3m04 AF 4.0 20.0 16.0 mAde EXC EXC EXC EXC EXC EXC EXC EXC EXC 432 1E32N050 317/04 AL 4.0 20.0 16.0 mAde 0.25000 25.18750 50.12500 75.06250 100.12500 75.06250 50.18750 25.25000 0.25000 433 1E32N05O 9/28/02 AF 4.0 20.0 16.0 mAde 0.00000 25.18750 50.06250 75.06250 100.06250 75.06250 50.12500 25.18750 0.06250 434 1E32N050 9/28/02 AL 4.0 20.0 16.0 mAde 0.00000 25.18750 50.06250 75.06250 100.06250 75.06250 50.12500 25.18750 0.06250 435 1E32N050 5/3/01 AF 4.0 20.0 16.0 mAde

-2.31250 22.75000 47.68750 72.68750 97.75000 72.75000 47.87500 22.81250

-2.43750 436 1E32N050 5/3/01 AL 4.0 20.0 16.0 mAde 0.00000 25.06250 50.00000 75.00000 100.00000 75.00000 50.06250 24.93750

-0.06250 437 1E32N050 11/6/99 AF 4.0 20.0 16.0 mAde 1.43750 25.81250 49.93750 74.18750 98.43750 74.12500 50.00000 25.75000 1.50000 438 1E32N050 11/6/99 AL 4.0 20.0 16.0 mAde 0.06250 25.00000 49.93750 74.93750 99.87500 74.93750 49.93750 25.00000 0.06250 439 1E32N050 5/31/99 AF 4.0 20.0 16.0 mAde

-0.11875 25.86875 51.50000 77.50000 103.41875 77.50000 51.50000 25.86875

-0.11875 440 1E32N050 5/31/99 AL 4.0 20.0 16.0 mAde 0.06250 24.87500 49.75000 74.87500 100.00000 74.87500 49.81250 24.93750 0.06250 441 1E32N050 10/6/97 AF 4.0 20.0 16.0 mAde

-0.18750 24.81250 49.93750 74.81250 99.87500 74.81250 50.06250 24.87500 0.00000 442 1E32N050 10/6/97 AL 4.0 20.0 16.0 mAde

-0.18750 24.81250 49.93750 74.81250 99.87500 74.81250 50.06250 24.87500 0.00000 443 1E32N055 7/8/09 AF 4.0 20.0 16.0 mAde 0.00000 24.93750 49.93750 75.00000 100.12500 75.00000 50.06250 25.00000 0.00000 444 1E32N055 7/8/09 AL 4.0 20.0 16.0 mAde 0.00000 24.93750 49.93750 75.00000 100.12500 75.00000 50.06250 25.00000 0.00000 445 1E32N055 1m08 AF 4.0 20.0 16.0 mAde

-0.06250 25.00000 50.00000 75.06250 100.25000 75.06250 50.06250 25.06250 0.00000 446 1E32N055 1/7/08 AL 4.0 20.0 16.0 mAde

-0.06250 25.00000 50.00000 75.06250 100.25000 75.06250 50.06250 25.06250 0.00000 447 1E32N055 4/5/06 AF 4.0 20.0 16.0 mAde 0.00000 24.87500 49.87500 74.81250 100.00000 74.87500 49.87500 24.93750 0.00000 448 1E32N055 4/5/06 AL 4.0 20.0 16.0 mAde 0.00000 24.87500 49.87500 74.81250 100.00000 74.87500 49.87500 24.93750 0.00000 449 1E32N055 10/6/04 AF 4.0 20.0 16.0 mAde 0.06250 24.81250 49.56250 74.62500 99.93750 74.62500 49.68750 24.81250 0.12500 450 1E32N055 10/6/04 AL 4.0 20.0 16.0 mAde 0.00000 24.87500 49.75000 74.81250 100.00000 74.87500 49.87500 24.87500

-0.06250 451 1E32N055 4/22/03 AF 4.0 20.0 16.0 mAde 0.25000 25.12500 50.00000 75.00000 100.18750 75.00000 50.06250 25.12500 0.25000 452 1E32N055 4/22103 AL 4.0 20.0 16.0 mAde 0.18750 25.00000 49.81250 74.81250 100.12500 74.87500 49.81250 25.00000 0.18750 453 1E32N055 11/19/01 AF 4.0 20.0 16.0 mAde 0.31250 24.93750 49.87500 74.62500 99.68750 74.56250 49.75000 24.81250 0.25000 454 1E32N055 11/19/01 AL 4.0 20.0 16.0 mAde 0.00000 24.93750 49.93750 74.81250 99.93750 74.75000 50.00000 25.00000 0.00000 455 1E32N055 8/17/00 AF 4.0 20.0 16.0 mAde 0.06250 24.75000 49.56250 74.56250 99.75000 74.62500 49.75000 24.87500

-0.06250 456 1E32N055 8/17/00 AL 4.0 20.0 16.0 mAde 0.00000 25.00000 49.81250 74.81250 100.06250 74.81250 49.87500 24.93750 0.06250 457 1E32N055 2/16/99 AF 4.0 20.0 16.0 mAde 0.06250 24.93750 49.93750 74.93750 99.93750 74.81250 50.00000 25.06250

-0.12500 458 1E32N055 2/16/99 AL 4.0 20.0 16.0 mAde 0.06250 24.93750 49.93750 74.93750 99.93750 74.81250 50.00000 25.06250

-0.12500 459 1E32N055 8/19/97 AF 4.0 20.0 16.0 mAde

-0.06250 25.00000 49.87500 74.87500 99.93750 74.87500 49.87500 25.12500 0.00000 460 1E32N055 8/19/97 AL 4.0 20.0 16.0 mAde

-0.06250 25.00000 49.87500 74.87500 99.93750 74.87500 49.87500 25.12500 0.00000 461 1E32N058 4/30/10 AF 4.0 20.0 16.0 mAde

-0.06250 25.06250 50.00000 74.93750 99.93750 74.93750 50.06250 25.06250

-0.06250 462 1E32N058 4/30/10 AL 4.0 20.0 16.0 mAde

-0.06250 25.06250 50.00000 74.93750 99.93750 74.93750 50.06250 25.06250

-0.06250 463 1E32N058 10/2108 AF 4.0 20.0 16.0 mAde 0.00000 25.12500 50.12500 75.12500 100.18750 75.12500 50.18750 25.12500 0.00000 464 1E32N058 10/2108 AL 4.0 20.0 16.0 mAde 0.00000 25.12500 50.12500 75.12500 100.18750 75.12500 50.18750 25.12500 0.00000 465 1E32N058 3/25/07 AF 4.0 20.0 16.0 mAde

-0.06250 25.12500 50.12500 75.12500 100.18750 75.12500 50.12500 25.12500

-0.06250 466 1E32N058 3/25/07 AL 4.0 20.0 16.0 mAde

-0.06250 25.12500 50.12500 75.12500 100.18750 75.12500 50.12500 25.12500

-0.06250

DRIFT ANALYSIS ENGINEERING DEPARTMENT GRAND GULF NUCLEAR STATION Rosemount Range Codes 5 - 8 Gage Pressure Transmitters Data Conversion JC-Q1111-09019 Rev. 0 Page 87 of 134 IDENTIFYING INFORMATION RANGE VALUES AF/AL CONVERTED TO % SPAN (AFAL-Min)*100%/Span Seq.

Tag 10 Span 1

2 3

4 5

6 7

8 9

10 Date AF/AL Min Max (Max-Min)

Units (0% Up)

(25% Up)

(50% Up)

(75% Up)

(100% Up)

(75% On)

(50% On)

(25% On)

(0% On) 467 1E32N058 9/22/05 AF 4.0 20.0 16.0 mAde 0.00000 25.06250 50.00000 74.93750 99.93750 74.93750 50.06250 25.06250 0.00000 468 1E32N058 9/22/05 AL 4.0 20.0 16.0 mAde 0.00000 25.06250 50.00000 74.93750 99.93750 74.93750 50.06250 25.06250 0.00000 469 1E32N058 3/5/04 AF 4.0 20.0 16.0 mAde EXC EXC EXC EXC EXC EXC EXC EXC EXC 470 1E32N058 3/5/04 AL 4.0 20.0 16.0 mAde 0.00000 25.06250 50.00000 74.93750 99.87500 74.93750 50.06250 25.12500 0.00000 471 1E32N058 9/15/02 AF 4.0 20.0 16.0 mAde

-0.62500 24.62500 49.68750 74.50000 99.56250 74.50000 49.56250 24.62500

-0.62500 472 1E32N058 9/15/02 AL 4.0 20.0 16.0 mAde

-0.06250 25.12500 50.06250 74.93750 99.93750 74.93750 50.06250 25.12500

-0.18750 473 1E32N058 4/23/01 AF 4.0 20.0 16.0 mAde

-7.81250 13.62500 37.31250 60.87500 85.00000 60.87500 37.43750 13.62500

-7.81250 474 1E32N058 4/23/01 AL 4.0 20.0 16.0 mAde 0.00000 25.12500 50.12500 75.12500 100.12500 75.12500 50.12500 25.12500 0.00000 475 1E32N058 11/9/99 AF 4.0 20.0 16.0 mAde EXC EXC EXC EXC EXC EXC EXC EXC EXC 476 1E32N058 11/9/99 AL 4.0 20.0 16.0 mAde EXC EXC EXC EXC EXC EXC EXC EXC EXC 477 1E32N058 6/21/99 AF 4.0 20.0 16.0 mAde 0.93750 27.00000 52.68750 78.43750 104.37500 78.43750 52.68750 27.00000 0.87500 478 1E32N058 6/21/99 AL 4.0 20.0 16.0 mAde 0.00000 25.00000 49.87500 74.87500 100.00000 74.87500 49.93750 25.00000

-0.06250 479 1E32N058 10/28/97 AF 4.0 20.0 16.0 mAde

-0.18750 24.87500 50.00000 75.06250 100.25000 75.18750 50.12500 25.00000

-0.25000 480 1E32N058 10/28197 AL 4.0 20.0 16.0 mAde 0.06250 25.12500 49.93750 74.87500 99.93750 74.87500 50.06250 25.00000

-0.06250 481 1E32N061A 8/12/09 AF 4.0 20.0 16.0 mAde 0.06250 25.06250 50.00000 74.93750 100.00000 75.00000 50.00000 25.06250 0.06250 482 1E32N061A 8/12/09 AL 4.0 20.0 16.0 mAde 0.06250 25.06250 50.00000 74.93750 100.00000 75.00000 50.00000 25.06250 0.06250 483 1E32N061 A 2/15/08 AF 4.0 20.0 16.0 mAde 0.00000 25.00000 50.00000 74.93750 100.00000 74.93750 50.00000 25.00000 0.00000 484 1E32N061A 2115/08 AL 4.0 20.0 16.0 mAde 0.00000 25.00000 50.00000 74.93750 100.00000 74.93750 50.00000 25.00000 0.00000 485 1E32N061A 8/28/06 AF 4.0 20.0 16.0 mAde 0.06250 25.06250 50.00000 74.93750 100.00000 75.00000 50.00000 25.06250 0.06250 486 1E32N061A 8/28/06 AL 4.0 20.0 16.0 mAde 0.06250 25.06250 50.00000 74.93750 100.00000 75.00000 50.00000 25.06250 0.06250 487 1E32N061A 1nJ05 AF 4.0 20.0 16.0 mAde EXC EXC EXC EXC EXC EXC EXC EXC EXC 488 1E32N061A 1nJ05 AL 4.0 20.0 16.0 mAde 0.00000 25.00000 50.00000 74.93750 100.00000 75.00000 50.00000 25.00000 0.00000 489 1E32N061A 5/13/03 AF 4.0 20.0 16.0 mAde

-0.31250 24.81250 49.68750 74.68750 99.68750 74.68750 49.68750 24.81250

-0.31250 490 1E32N061A 5/13/03 AL 4.0 20.0 16.0 mAde 0.00000 25.12500 50.00000 75.00000 100.00000 75.00000 50.00000 25.12500 0.00000 491 1E32N061A 11/26/01 AF 4.0 20.0 16.0 mAde 0.06250 25.12500 50.43750 75.50000 100.62500 75.43750 50.50000 25.18750 0.12500 492 1E32N061A 11/26/01 AL 4.0 20.0 16.0 mAde 0.00000 25.12500 50.12500 75.06250 100.00000 75.00000 50.12500 25.18750 0.00000 493 1E32N061A 10/2/00 AF 4.0 20.0 16.0 mAde 0.00000 24.81250 49.68750 74.37500 99.37500 74.43750 49.68750 24.93750 0.00000 494 1E32N061A 10/2100 AL 4.0 20.0 16.0 mAde 0.12500 25.06250 50.06250 75.00000 100.12500 75.06250 50.12500 25.18750 0.18750 495 1E32N061A 4/9/99 AF 4.0 20.0 16.0 mAde 0.25000 25.00000 50.00000 75.00000 100.06250 75.06250 50.12500 25.12500 0.18750 496 1E32N061A 4/9/99 AL 4.0 20.0 16.0 mAde 0.25000 25.00000 50.00000 75.00000 100.06250 75.06250 50.12500 25.12500 0.18750 497 1E32N061A 10/8/97 AF 4.0 20.0 16.0 mAde 0.62500 25.62500 50.56250 75.68750 100.62500 75.68750 50.56250 25.68750 0.62500 498 1E32N061A 10/8/97 AL 4.0 20.0 16.0 mAde

-0.06250 25.00000 50.00000 75.00000 100.00000 75.00000 50.00000 25.00000 0.00000 499 1E32N061E 11/2109 AF 4.0 20.0 16.0 mAde

-0.12500 24.87500 49.93750 74.93750 99.93750 74.93750 49.93750 24.93750

-0.12500 500 1E32N061E 11/2/09 AL 4.0 20.0 16.0 mAde

-0.12500 24.87500 49.93750 74.93750 99.93750 74.93750 49.93750 24.93750

-0.12500 501 1E32N061E 1/30/08 AF 4.0 20.0 16.0 mAde

-0.06250 24.93750 49.93750 74.93750 99.93750 74.93750 49.93750 24.93750

-0.06250 502 1E32N061E 1/30/08 AL 4.0 20.0 16.0 mAde

-0.06250 24.93750 49.93750 74.93750 99.93750 74.93750 49.93750 24.93750

-0.06250 503 1E32N061E 4/14/06 AF 4.0 20.0 16.0 mAde 0.25000 25.25000 50.25000 75.18750 100.25000 75.18750 50.25000 25.25000 0.25000 504 1E32N061E 4/14/06 AL 4.0 20.0 16.0 mAde 0.00000 25.00000 50.00000 74.93750 100.00000 74.93750 49.93750 25.00000 0.00000 505 1E32N061E 10/28/04 AF 4.0 20.0 16.0 mAde EXC EXC EXC EXC EXC EXC EXC EXC EXC 506 1E32N061E 10/28/04 AL 4.0 20.0 16.0 mAde 0.18750 25.12500 50.12500 75.06250 100.00000 75.06250 50.12500 25.12500 0.18750 507 1E32N061E 5/28/03 AF 4.0 20.0 16.0 mAde

-0.43750 24.56250 49.50000 74.43750 99.43750 74.43750 49.50000 24.56250

-0.43750 508 1E32N061E 5/28/03 AL 4.0 20.0 16.0 mAde

-0.06250 24.93750 49.93750 74.93750 99.93750 74.93750 49.93750 24.93750

-0.06250 509 1E32N061E 11/28/01 AF 4.0 20.0 16.0 mAde

-0.25000 24.81250 49.75000 74.56250 99.37500 74.50000 49.75000 24.81250

-0.25000 510 1E32N061E 11/28/01 AL 4.0 20.0 16.0 mAde 0.00000 25.06250 50.06250 75.00000 99.93750 74.93750 50.00000 25.06250 0.00000 511 1E32N061E 11/30/00 AF 4.0 20.0 16.0 mAde 0.12500 25.25000 50.37500 75.43750 100.37500 75.37500 50.43750 25.25000 0.18750 512 1E32N061E 11/30/00 AL 4.0 20.0 16.0 mAde 0.06250 25.12500 50.18750 75.06250 99.87500 75.00000 50.18750 25.12500 0.06250 513 1E32N061E 4/9/99 AF 4.0 20.0 16.0 mAde

-0.18750 24.75000 49.62500 74.62500 99.68750 74.68750 49.62500 24.68750

-0.31250

DRIFT ANALYSIS ENGINEERING DEPARTMENT GRAND GULF NUCLEAR STATION Rosemount Range Codes 5 - 8 Gage Pressure Transmitters Data Conversion JC-Q1111-09019 Rev. 0 Page 88 of 134 IDENTIFYING INFORMATION RANGE VALUES AFIAL CONVERTED TO % SPAN (AFAL-Min)*100%ISpan Seq.

Span 1

2 3

4 5

6 7

8 9

ID Tag ID Date AFIAL Min Max (Max-Min)

Units (0% Up)

(25% Up)

(50% Up)

(75% Up)

(100% Up)

(75% Dn)

(50% Dn)

(25% Dn)

(O%Dn) 514 1E32N061E 419199 AL 4.0 20.0 16.0 mAde 0.00000 24.93750 49.93750 74.93750 100.00000 75.00000 49.93750 25.00000

-0.06250 515 1E32N061E 1018197 AF 4.0 20.0 16.0 mAde 0.12500 24.93750 50.00000 75.06250 99.93750 74.93750 50.00000 25.06250

-0.06250 516 1E32N061E 1018/97 AL 4.0 20.0 16.0 mAde 0.12500 24.93750 50.00000 75.06250 99.93750 74.93750 50.00000 25.06250

-0.06250 517 1E32N061J 5/5/09 AF 4.0 20.0 16.0 mAde

-0.06250 24.81250 49.75000 74.81250 100.00000 74.75000 49.81250 24.81250 0.00000 518 1E32N061J 5/5/09 AL 4.0 20.0 16.0 mAde

-0.06250 24.81250 49.75000 74.81250 100.00000 74.75000 49.81250 24.81250 0.00000 519 1E32N061J 1119/07 AF 4.0 20.0 16.0 mAde 0.18750 25.06250 50.00000 75.00000 100.18750 74.93750 49.93750 25.00000 0.12500 520 1E32N061J 1119/07 AL 4.0 20.0 16.0 mAde 0.18750 25.06250 50.00000 75.00000 100.18750 74.93750 49.93750 25.00000 0.12500 521 1E32N061J 5111106 AF 4.0 20.0 16.0 mAde 0.18750 24.87500 49.68750 74.62500 99.68750 74.62500 49.68750 24.93750 0.18750 522 1E32N061J 5111106 AL 4.0 20.0 16.0 mAde 0.12500 24.93750 49.81250 74.87500 100.12500 74.87500 49.87500 24.93750 0.12500 523 1E32N061J 9/29/04 AF 4.0 20.0 16.0 mAde EXC EXC EXC EXC EXC EXC EXC EXC EXC 524 1E32N061J 9/29/04 AL 4.0 20.0 16.0 mAde 0.25000 25.00000 49.75000 74.75000 99.87500 74.81250 49.87500 25.00000 0.25000 525 1E32N061J 4/3/03 AF 4.0 20.0 16.0 mAde

-0.12500 24.87500 49.87500 74.87500 100.06250 74.93750 49.87500 24.87500

-0.12500 526 1E32N061J 4/3/03 AL 4.0 20.0 16.0 mAde 0.00000 24.87500 49.75000 74.75000 100.00000 74.81250 49.81250 24.87500 0.00000 527 1E32N061J 11/12/01 AF 4.0 20.0 16.0 mAde

-0.25000 24.56250 49.56250 74.75000 100.12500 74.75000 49.62500 24.62500

-0.37500 528 1E32N061J 11/12101 AL 4.0 20.0 16.0 mAde 0.00000 24.87500 49.87500 74.87500 100.00000 74.87500 49.87500 24.87500 0.00000 529 1E32N061J 7/24/00 AF 4.0 20.0 16.0 mAde 0.81250 25.56250 50.56250 75.62500 100.75000 75.56250 50.56250 25.68750 0.93750 530 1E32N061J 7/24/00 AL 4.0 20.0 16.0 mAde

-0.12500 24.75000 49.81250 74.87500 100.00000 74.87500 49.75000 24.81250

-0.06250 531 1E32N061J 1/27/99 AF 4.0 20.0 16.0 mAde 0.18750 25.06250 50.00000 75.06250 100.18750 75.06250 50.00000 25.06250 0.18750 532 1E32N061J 1/27/99 AL 4.0 20.0 16.0 mAde 0.18750 25.06250 50.00000 75.06250 100.18750 75.06250 50.00000 25.06250 0.18750 533 1E32N061J 7/16/97 AF 4.0 20.0 16.0 mAde

-0.68750 24.18750 49.06250 73.81250 98.87500 73.62500 48.75000 24.12500

-0.62500 534 1E32N061J 7/16/97 AL 4.0 20.0 16.0 mAde 0.12500 25.06250 49.93750 74.93750 100.00000 74.87500 49.81250 24.93750 0.12500 535 1E32N061N 1218/09 AF 4.0 20.0 16.0 mAde 0.06250 25.00000 50.00000 75.00000 100.00000 75.00000 50.00000 25.06250 0.06250 536 1E32N061N 1218109 AL 4.0 20.0 16.0 mAde 0.06250 25.00000 50.00000 75.00000 100.00000 75.00000 50.00000 25.06250 0.06250 537 1E32N061N 6116/08 AF 4.0 20.0 16.0 mAde 0.06250 25.06250 50.00000 74.93750 100.06250 75.00000 50.00000 25.06250 0.06250 538 1E32N061N 6/16/08 AL 4.0 20.0 16.0 mAde 0.06250 25.06250 50.00000 74.93750 100.06250 75.00000 50.00000 25.06250 0.06250 539 1E32N061N 8/28/06 AF 4.0 20.0 16.0 mAde 0.06250 25.06250 50.00000 75.00000 100.06250 75.00000 50.06250 25.06250 0.06250 540 1E32N061N 8/28/06 AL 4.0 20.0 16.0 mAde 0.06250 25.06250 50.00000 75.00000 100.06250 75.00000 50.06250 25.06250 0.06250 541 1E32N061N 117105 AF 4.0 20.0 16.0 mAde EXC EXC EXC EXC EXC EXC EXC EXC EXC 542 1E32N061N 117105 AL 4.0 20.0 16.0 mAde 0.06250 25.06250 50.00000 75.00000 100.06250 75.00000 50.06250 25.00000 0.06250 543 1E32N061N 5/16/03 AF 4.0 20.0 16.0 mAde

-0.50000 24.50000 49.50000 74.56250 99.75000 74.62500 49.56250 24.56250

-0.50000 544 1E32N061N 5/16/03 AL 4.0 20.0 16.0 mAde 0.06250 25.06250 50.12500 75.06250 100.12500 75.12500 50.12500 25.06250 0.06250 545 1E32N061N 11/12/01 AF 4.0 20.0 16.0 mAde

-0.25000 24.75000 49.81250 74.81250 99.93750 74.81250 49.81250 24.81250

-0.25000 546 1E32N061N 11/12/01 AL 4.0 20.0 16.0 mAde 0.00000 25.00000 50.00000 74.93750 100.00000 74.93750 50.00000 25.00000 0.00000 547 1E32N061N 10/2/00 AF 4.0 20.0 16.0 mAde 0.50000 25.25000 49.87500 74.62500 99.62500 74.68750 49.93750 25.18750 0.43750 548 1E32N061N 10/2/00 AL 4.0 20.0 16.0 mAde

-0.06250 25.00000 49.93750 74.87500 99.93750 74.87500 49.93750 24.93750 0.06250 549 1E32N061N 4/10/99 AF 4.0 20.0 16.0 mAde 0.08750 24.88750 49.95625 74.91875 99.89375 74.93750 49.93125 24.95000 0.07500 550 1E32N061N 4/10/99 AL 4.0 20.0 16.0 mAde 0.08750 24.88750 49.95625 74.91875 99.89375 74.93750 49.93125 24.95000 0.07500 551 1E32N061N 1017197 AF 4.0 20.0 16.0 mAde 0.18750 25.18750 50.12500 74.81250 99.81250 74.87500 50.06250 25.00000

-0.06250 552 1E32N061N 1017197 AL 4.0 20.0 16.0 mAde 0.18750 25.18750 50.12500 74.81250 99.81250 74.87500 50.06250 25.00000

-0.06250 553 1E51N035A 4/24/10 AF 4.0 20.0 16.0 mAde 0.18750 25.25000 49.37500 74.43750 99.50000 74.56250 49.43750 25.31250 0.12500 554 1E51N035A 4/24/10 AL 4.0 20.0 16.0 mAde 0.18750 25.25000 49.37500 74.43750 99.50000 74.56250 49.43750 25.31250 0.12500 555 1E51N035A 7/2/08 AF 4.0 20.0 16.0 mAde 0.06250 25.25000 49.31250 74.43750 99.56250 74.50000 49.31250 25.25000 0.12500 556 1E51N035A 7/2/08 AL 4.0 20.0 16.0 mAde 0.18750 25.31250 49.43750 74.50000 99.56250 74.50000 49.37500 25.31250 0.18750 557 1E51N035A 211/08 AF 4.0 20.0 16.0 mAde 0.12500 25.25000 49.37500 74.50000 99.50000 74.50000 49.43750 25.25000 0.12500 558 1E51N035A 211/08 AL 4.0 20.0 16.0 mAde 0.12500 25.25000 49.37500 74.50000 99.50000 74.50000 49.43750 25.25000 0.12500 559 1E51N035A 8/5/06 AF 4.0 20.0 16.0 mAde EXC EXC EXC EXC EXC EXC EXC EXC EXC 560 1E51N035A 815/06 AL 4.0 20.0 16.0 mAde 0.18750 25.31250 49.37500 74.50000 99.62500 74.50000 49.37500 25.25000 0.06250

DRIFT ANALYSIS ENGINEERING DEPARTMENT GRAND GULF NUCLEAR STATION Rosemount Range Codes 5 - 8 Gage Pressure Transmitters Data Conversion JC-Q1111-09019 Rev. 0 Page 89 of 134 IDENTIFYING INFORMATION RANGE VALUES AF/AL CONVERTED TO % SPAN (AFAL-Min)*100%/Span Seq.

Tag 10 Date Span 1

2 3

4 5

6 7

8 9

10 AF/AL Min Max (Max-Min)

Units (0% Up)

(25% Up)

(50% Up)

(75% Up)

(100% Up)

(75% On)

(50% On)

(25% On)

(0% On) 561 1E51N035E 4/25/10 AF 4.0 20.0 16.0 mAde 0.43750 25.31250 49.31250 74.50000 99.75000 74.56250 49.37500 25.37500 0.43750 562 1E51N035E 4/25/10 AL 4.0 20.0 16.0 mAde 0.12500 25.12500 49.18750 74.31250 99.62500 74.31250 49.25000 25.12500 0.12500 563 1E51N035E 6/30/08 AF 4.0 20.0 16.0 mAde 0.18750 25.31250 49.43750 74.62500 99.68750 74.56250 49.50000 25.31250 0.12500 564 1E51N035E 6/30/08 AL 4.0 20.0 16.0 mAde 0.25000 25.25000 49.31250 74.50000 99.75000 74.50000 49.37500 25.25000 0.25000 565 1E51N035E 10/8/06 AF 4.0 20.0 16.0 mAde EXC EXC EXC EXC EXC EXC EXC EXC EXC 566 1E51N035E 10/8/06 AL 4.0 20.0 16.0 mAde 0.12500 25.25000 49.37500 74.50000 99.62500 74.50000 49.37500 25.31250 0.18750 567 1E51N055A 6/29/09 AF 4.0 20.0 16.0 mAde 0.06250 25.00000 50.00000 74.93750 100.00000 75.00000 50.00000 25.00000 0.06250 568 1E51N055A 6/29/09 AL 4.0 20.0 16.0 mAde 0.06250 25.00000 50.00000 74.93750 100.00000 75.00000 50.00000 25.00000 0.06250 569 1E51N055A 1/2108 AF 4.0 20.0 16.0 mAde 0.00000 25.00000 50.00000 75.00000 100.12500 75.00000 50.00000 25.00000 0.00000 570 1E51N055A 1/2/08 AL 4.0 20.0 16.0 mAde 0.00000 25.00000 50.00000 75.00000 100.12500 75.00000 50.00000 25.00000 0.00000 571 1E51N055A 3/18/06 AF 4.0 20.0 16.0 mAde 0.00000 25.00000 50.06250 75.12500 100.18750 75.12500 50.12500 25.06250 0.00000 572 1E51N055A 3/18/06 AL 4.0 20.0 16.0 mAde 0.00000 25.00000 50.06250 75.12500 100.18750 75.12500 50.12500 25.06250 0.00000 573 1E51N055A 8/4/04 AF 4.0 20.0 16.0 mAde 0.06250 25.00000 50.00000 75.00000 100.06250 75.00000 50.00000 25.00000 0.00000 574 1E51N055A 8/4/04 AL 4.0 20.0 16.0 mAde 0.06250 25.00000 50.00000 75.00000 100.06250 75.00000 50.00000 25.00000 0.00000 575 1E51N055A 2/19/03 AF 4.0 20.0 16.0 mAde

-0.12500 24.81250 49.75000 74.68750 99.68750 74.68750 49.75000 24.81250

-0.12500 576 1E51N055A 2/19/03 AL 4.0 20.0 16.0 mAde 0.00000 25.00000 50.00000 75.00000 100.00000 75.00000 50.00000 25.00000 0.00000 577 1E51N055A 4/24/01 AF 4.0 20.0 16.0 mAde

-0.12500 24.87500 49.81250 74.81250 99.81250 74.81250 49.81250 24.87500

-0.12500 578 1E51N055A 4/24/01 AL 4.0 20.0 16.0 mAde

-0.12500 24.87500 49.81250 74.81250 99.81250 74.81250 49.81250 24.87500

-0.12500 579 1E51N055A 10/29/99 AF 4.0 20.0 16.0 mAde 0.00000 25.06250 49.93750 74.93750 99.81250 74.87500 49.93750 25.00000 0.00000 580 1E51N055A 10/29/99 AL 4.0 20.0 16.0 mAde 0.00000 25.06250 49.93750 74.93750 99.81250 74.87500 49.93750 25.00000 0.00000 581 1E51N055A 4/20/98 AF 4.0 20.0 16.0 mAde 0.00000 24.81250 49.62500 74.50000 99.43750 74.50000 49.62500 24.81250 0.00000 582 1E51N055A 4/20/98 AL 4.0 20.0 16.0 mAde

-0.06250 24.93750 49.93750 74.93750 99.93750 74.93750 49.93750 24.93750

-0.06250 583 1E51N055B 11/4/10 AF 4.0 20.0 16.0 mAde

-0.06250 24.93750 49.93750 74.87500 99.87500 74.87500 49.93750 24.93750

-0.06250 584 1E51N055B 11/4/10 AL 4.0 20.0 16.0 mAde

-0.06250 24.93750 49.93750 74.87500 99.87500 74.87500 49.93750 24.93750

-0.06250 585 1E51N055B 1/22/09 AF 4.0 20.0 16.0 mAde 0.00000 25.00000 50.00000 75.00000 100.00000 75.00000 50.00000 25.00000 0.00000 586 1E51N055B 1/22/09 AL 4.0 20.0 16.0 mAde 0.00000 25.00000 50.00000 75.00000 100.00000 75.00000 50.00000 25.00000 0.00000 587 1E51N055B 8/10/07 AF 4.0 20.0 16.0 mAde

-0.06250 24.93750 49.93750 74.93750 100.00000 74.93750 49.93750 24.93750

-0.06250 588 1E51N055B 8/10/07 AL 4.0 20.0 16.0 mAde

-0.06250 24.93750 49.93750 74.93750 100.00000 74.93750 49.93750 24.93750

-0.06250 589 1E51N055B 219/06 AF 4.0 20.0 16.0 mAde

-0.06250 24.93750 49.93750 74.93750 100.00000 74.93750 49.93750 24.93750

-0.06250 590 1E51N055B 219/06 AL 4.0 20.0 16.0 mAde

-0.06250 24.93750 49.93750 74.93750 100.00000 74.93750 49.93750 24.93750

-0.06250 591 1E51N055B 5/4/04 AF 4.0 20.0 16.0 mAde

-0.06250 24.93750 49.93750 75.00000 100.12500 75.00000 49.93750 24.93750 0.00000 592 1E51N055B 5/4/04 AL 4.0 20.0 16.0 mAde

-0.06250 24.93750 49.93750 75.00000 100.12500 75.00000 49.93750 24.93750 0.00000 593 1E51N055B 11/20/02 AF 4.0 20.0 16.0 mAde

-0.06250 25.00000 50.00000 75.00000 100.12500 75.06250 50.00000 25.00000 0.00000 594 1E51N055B 11/20/02 AL 4.0 20.0 16.0 mAde

-0.06250 25.00000 50.00000 75.00000 100.12500 75.06250 50.00000 25.00000 0.00000 595 1E51N055B 4/20/01 AF 4.0 20.0 16.0 mAde

-0.06250 25.00000 49.87500 75.00000 100.06250 75.00000 49.87500 24.93750 0.00000 596 1E51N055B 4/20/01 AL 4.0 20.0 16.0 mAde

-0.06250 25.00000 49.87500 75.00000 100.06250 75.00000 49.87500 24.93750 0.00000 597 1E51N055B 11/16/99 AF 4.0 20.0 16.0 mAde

-0.06250 24.93750 50.00000 75.06250 100.12500 75.06250 49.93750 24.93750

-0.06250 598 1E51N055B 11/16/99 AL 4.0 20.0 16.0 mAde

-0.06250 24.93750 50.00000 75.06250 100.12500 75.06250 49.93750 24.93750

-0.06250 599 1E51N055B 4/20/98 AF 4.0 20.0 16.0 mAde 0.00000 24.93750 50.00000 75.06250 100.12500 75.06250 50.00000 25.00000

-0.06250 600 1E51N055B 4/20/98 AL 4.0 20.0 16.0 mAde 0.00000 24.93750 50.00000 75.06250 100.12500 75.06250 50.00000 25.00000

-0.06250 601 1E51N055E 2/26/10 AF 4.0 20.0 16.0 mAde

-0.18750 24.81250 49.81250 74.87500 100.00000 74.93750 49.93750 25.00000

-0.12500 602 1E51N055E 2/26/10 AL 4.0 20.0 16.0 mAde

-0.18750 24.81250 49.81250 74.87500 100.00000 74.93750 49.93750 25.00000

-0.12500 603 1E51N055E 7/3/08 AF 4.0 20.0 16.0 mAde

-0.12500 24.87500 49.87500 74.93750 100.06250 75.00000 50.00000 24.93750

-0.06250 604 1E51N055E 7/3/08 AL 4.0 20.0 16.0 mAde

-0.12500 24.87500 49.87500 74.93750 100.06250 75.00000 50.00000 24.93750

-0.06250 605 1E51N055E 10/10/06 AF 4.0 20.0 16.0 mAde

-0.12500 24.87500 49.93750 74.93750 99.93750 75.00000 49.93750 24.93750

-0.06250 606 1E51N055E 10/10/06 AL 4.0 20.0 16.0 mAde

-0.12500 24.87500 49.93750 74.93750 99.93750 75.00000 49.93750 24.93750

-0.06250 607 1E51N055E 12121/04 AF 4.0 20.0 16.0 mAde

-0.18750 24.87500 49.87500 74.93750 100.00000 74.93750 49.87500 24.87500

-0.12500

DRIFT ANALYSIS ENGINEERING DEPARTMENT GRAND GULF NUCLEAR STATION Rosemount Range Codes 5 - 8 Gage Pressure Transmitters Data Conversion JC-Q1111-09019 Rev. 0 Page 90 of 134 IDENTIFYING INFORMATION RANGE VALUES AF/AL CONVERTED TO % SPAN (AFAL-Min)*100%/Span Seq.

Tag 10 Span 1

2 3

4 5

6 7

8 9

10 Date AF/AL Min Max (Max-Min)

Units (0% Up)

(25% Up)

(50% Up)

(75% Up)

(100% Up)

(75% On)

(50% On)

(25% On)

(0% On) 608 1E51N055E 12121/04 AL 4.0 20.0 16.0 mAde

-0.18750 24.87500 49.87500 74.93750 100.00000 74.93750 49.87500 24.87500

-0.12500 609 1E51N055E 2/19/03 AF 4.0 20.0 16.0 mAde

-0.25000 24.81250 49.81250 74.87500 99.87500 74.93750 49.93750 24.87500

-0.18750 610 1E51N055E 2/19/03 AL 4.0 20.0 16.0 mAde

-0.25000 24.81250 49.81250 74.87500 99.87500 74.93750 49.93750 24.87500

-0.18750 611 1E51N055E 4/25/01 AF 4.0 20.0 16.0 mAde

-0.12500 25.00000 50.06250 75.06250 100.18750 75.12500 50.12500 25.06250

-0.06250 612 1E51N055E 4/25/01 AL 4.0 20.0 16.0 mAde

-0.12500 25.00000 50.06250 75.06250 100.18750 75.12500 50.12500 25.06250

-0.06250 613 1E51N055E 10/29/99 AF 4.0 20.0 16.0 mAde

-0.12500 24.93750 49.93750 75.12500 100.00000 75.06250 50.00000 24.93750

-0.12500 614 1E51N055E 10/29/99 AL 4.0 20.0 16.0 mAde

-0.12500 24.93750 49.93750 75.12500 100.00000 75.06250 50.00000 24.93750

-0.12500 615 1E51N055E 4/20/98 AF 4.0 20.0 16.0 mAde

-0.25000 24.87500 49.87500 75.00000 100.06250 75.06250 50.06250 24.93750

-0.18750 616 1E51N055E 4/20/98 AL 4.0 20.0 16.0 mAde

-0.25000 24.87500 49.87500 75.00000 100.06250 75.06250 50.06250 24.93750

-0.18750 617 1E51N055F 6/9/09 AF 4.0 20.0 16.0 mAde 0.06250 25.00000 49.93750 75.00000 100.06250 75.00000 50.00000 25.06250 0.12500 618 1E51N055F 6/9/09 AL 4.0 20.0 16.0 mAde 0.06250 25.00000 49.93750 75.00000 100.06250 75.00000 50.00000 25.06250 0.12500 619 1E51N055F 9/20/07 AF 4.0 20.0 16.0 mAde 0.06250 25.06250 50.06250 75.06250 100.12500 75.06250 50.06250 25.06250 0.12500 620 1E51 N055F 9/20/07 AL 4.0 20.0 16.0 mAde 0.06250 25.06250 50.06250 75.06250 100.12500 75.06250 50.06250 25.06250 0.12500 621 1E51N055F 1/24/06 AF 4.0 20.0 16.0 mAde 0.06250 25.00000 49.93750 75.00000 100.06250 75.00000 49.93750 25.00000 0.06250 622 1E51N055F 1/24/06 AL 4.0 20.0 16.0 mAde 0.06250 25.00000 49.93750 75.00000 100.06250 75.00000 49.93750 25.00000 0.06250 623 1E51N055F 5/6/04 AF 4.0 20.0 16.0 mAde

-0.06250 24.93750 49.93750 74.93750 100.00000 74.93750 49.93750 25.00000 0.00000 624 1E51N055F 5/6/04 AL 4.0 20.0 16.0 mAde

-0.06250 24.93750 49.93750 74.93750 100.00000 74.93750 49.93750 25.00000 0.00000 625 1E51N055F 11/21/02 AF 4.0 20.0 16.0 mAde 0.06250 25.00000 49.93750 75.00000 100.00000 75.00000 49.93750 25.00000 0.06250 626 1E51N055F 11/21/02 AL 4.0 20.0 16.0 mAde 0.06250 25.00000 49.93750 75.00000 100.00000 75.00000 49.93750 25.00000 0.06250 627 1E51N055F 4/20/01 AF 4.0 20.0 16.0 mAde

-0.06250 25.00000 49.93750 75.00000 100.12500 74.93750 49.87500 24.93750 0.06250 628 1E51N055F 4/20/01 AL 4.0 20.0 16.0 mAde

-0.06250 25.00000 49.93750 75.00000 100.12500 74.93750 49.87500 24.93750 0.06250 629 1E51N055F 11/16/99 AF 4.0 20.0 16.0 mAde 0.00000 25.12500 50.12500 75.18750 100.25000 75.25000 50.18750 25.12500 0.00000 630 1E51N055F 11/16/99 AL 4.0 20.0 16.0 mAde 0.00000 24.93750 49.87500 75.00000 100.06250 75.00000 49.87500 24.93750 0.00000 631 1E51N055F 4/20/98 AF 4.0 20.0 16.0 mAde

-0.06250 24.81250 49.75000 74.68750 99.68750 74.68750 49.75000 24.75000

-0.06250 632 1E51N055F 4/20/98 AL 4.0 20.0 16.0 mAde 0.00000 25.00000 49.93750 74.93750 100.00000 75.00000 50.00000 25.00000 0.00000

DRIFT ANALYSIS ENGINEERING DEPARTMENT GRAND GULF NUCLEAR STATION Rosemount Range Codes 5 - 8 Gage Pressure Transmitters AF-AL Data JC-Q1111-09019 Rev. 0 Page 91 of 134 DRIFT (% Span) =(Current Cal AF Data* Prev Cal AL Data)

CAL INTERVAL = (Current Seq.

Date* Previous Date) 10 1agiD Cal Date 1

2 3

4 5

6 7

8 9

Days Months (0% Up)

(25% Up)

(50% Up)

(75% Up)

(100% Up)

(75% On)

(50% On)

(25% On)

(0%

On) 1 1B21N201A 6/17/09 0.00000 0.00000 0.00000 0.06250 0.06250 0.06250 0.06250 0.00000 0.00000 659 21.7 3

1B21N201A 8/28107 0.06250 0.06250 0.00000

-0.06250

-0.12500

-0.06250 0.00000 0.06250 0.06250 658 21.6 5

1B21N201A 11/8105 0.00000 0.18750 0.31250 0.56250 1.18750 0.68750 0.31250 0.25000

-0.06250 546 17.9 7

1B21N201A 5/11/04 0.00000 0.06250 0.12500 0.18750 0.18750 0.12500 0.06250 0.06250 0.06250 533 17.5 9

1B21N201A 11/25/02

-0.06250 0.18750 0.12500 0.06250 0.06250 0.12500 0.18750 0.25000

-0.12500 580 19.1 11 1B21N201A 4/24/01 0.45000 0.06250

-0.19375

-0.13750

-0.01250

-0.05625

-0.08125 0.08125 0.43125 544 17.9 13 1B21N201A 10/28/99

-0.07500

-0.06250 0.13125 0.07500

-0.05000 0.11875 0.08125

-0.08125

-0.05625 555 18.2 17 1B21N201B 12/3/10 0.06250 0.06250 0.00000 0.00000 0.00000 0.00000 0.00000 0.06250 0.06250 612 20.1 19 1B21N201B 3/31/09 0.00000 0.06250

-0.02500 0.06250 0.00000 0.00000 0.00000 0.06250 0.00000 536 17.6 21 1B21N201B 10/12/07 0.00000 0.00000 0.00000

-0.12500 0.06250

-0.06250 0.00000

-0.06250 0.00000 583 19.2 23 1B21N201B 3/8/06 0.00000

-0.06250

-0.03750 0.00000

-0.12500 0.00000

-0.06250

-0.06250 0.00000 601 19.7 25 1B21N201B 7/15/04 0.00000 0.18750 0.06250 0.25000 0.25000 0.25000 0.18750 0.25000 0.12500 630 20.7 27 1B21N201B 10/24/02 0.06250

-0.12500 0.00000

-0.18750

-0.18750

-0.18750

-0.12500

-0.12500

-0.06250 549 18.0 29 1B21N201B 4/23/01 0.00000 0.00000 0.06250 0.12500 0.00000 0.00000

-0.12500

-0.06250

-0.06250 535 17.6 31 1B21N201B 11/5/99 0.06250 0.06250

-0.12500

-0.18750

-0.06250 0.00000 0.06250 0.12500 0.06250 568 18.7 35 1C61N102 8/12109 0.06250 0.00000

-0.06250 0.00000

-0.12500

-0.06250

-0.06250 0.00000 0.06250 544 17.9 37 1C61N102 2115/08 0.12500 0.12500 0.12500 0.06250 0.06250 0.06250 0.06250 0.18750 0.12500 533 17.5 39 1C61N102 8131/06 0.06250 0.06250 0.12500 0.12500 0.12500 0.18750 0.12500 0.06250 0.06250 589 19.4 41 1C61N102 1/19/05

-0.25000

-0.18750

-0.18750

-0.12500

-0.06250

-0.12500

-0.18750

-0.25000

-0.25000 531 17.4 43 1C61N102 8/7/03 0.00000

-0.06250

-0.06250

-0.06250

-0.06250

-0.06250 0.00000 0.00000 0.00000 545 17.9 45 1C61N102 2/8/02 0.12500 0.12500 0.00000 0.12500 0.12500 0.12500 0.06250 0.12500 0.06250 542 17.8 47 1C61N102 8/15/00

-0.18750

-0.06250 0.06250

-0.06250

-0.06250 0.00000 0.06250 0.00000

-0.12500 505 16.6 51 1E12N053A 8112109 0.00000 0.00000 0.06250 0.06250 0.06250 0.00000 0.06250 0.06250

-0.06250 544 17.9 53 1E12N053A 2115108

-0.12500

-0.06250

-0.18750

-0.12500

-0.12500

-0.12500

-0.06250

-0.06250

-0.06250 534 17.5 55 1E12N053A 8130/06 0.00000 0.00000 0.12500 0.06250 0.06250 0.06250 0.00000

-0.06250 0.00000 531 17.4 57 1E12N053A 3/17/05 0.00000 0.00000

-0.06250

-0.06250

-0.06250

-0.06250

-0.06250 0.00000 0.06250 531 17.4 59 1E12N053A 10/3/03

-0.06250

-0.18750

-0.18750

-0.18750

-0.18750

-0.18750

-0.18750

-0.12500

-0.06250 534 17.5 61 1E12N053A 4/17/02

-0.06250 0.06250

-0.06250 0.00000

-0.06250 0.06250 0.00000 0.06250

-0.06250 548 18.0 63 1E12N053A 10/16/00 0.06250 0.00000 0.00000

-0.06250 0.12500 0.00000 0.06250 0.06250 0.06250 574 18.9 65 1E12N053A 3/22199

-0.11875

-0.06250 0.00000

-0.11250 0.17500

-0.00625

-0.01875

-0.09375

-0.05625 573 18.8 69 1E12N053B 12/14/09

-0.12500

-0.06250

-0.06250

-0.06250

-0.06250

-0.18750

-0.06250

-0.06250

-0.31250 564 18.5 71 1E12N053B 5/29/08

-0.25000 0.06250 0.06250 0.06250 0.12500 0.12500 0.06250 0.06250 0.00000 547 18.0 73 1E12N053B 11/29/06 0.00000 0.00000

-0.06250

-0.12500

-0.12500

-0.18750

-0.12500

-0.06250 0.00000 558 18.3 75 1E12N053B 5/20/05 0.00000 0.00000 0.06250 0.00000 0.00000 0.00000 0.00000

-0.06250 0.00000 547 18.0

DRIFT ANALYSIS ENGINEERING DEPARTMENT GRAND GULF NUCLEAR STATION Rosemount Range Codes 5 - 8 Gage Pressure Transmitters AF-AL Data JC-Q1111-09019 Rev. 0 Page 92 of 134 DRIFT (% Span) =(Current Cal AF Data* Prev Cal AL Data)

CAL INTERVAL=(Current Sea.

Date* Previous Date) 10 Tag 10 Cal Date 1

2 3

4 5

6 7

8 9

Days Months (0% Up)

(25% Up)

(50% Up)

(75°1.. Up)

(100% Up)

(75% On)

(50% On)

(25°,<, On)

(0% On) 77 1E12N053B 11/20/03

-0.12500

-0.12500

-0.12500

-0.06250

-0.06250

-0.06250

-0.12500

-0.06250

-0.18750 491 16.1 79 1E12N053B 7/17/02 0.00000 0.06250

-0.12500

-0.12500 0.00000

-0.06250 0.06250 0.06250 0.06250 657 21.6 81 1E12N053B 9/28/00 0.12500

-0.12500 0.06250 0.00000

-0.06250

-0.06250

-0.12500

-0.12500 0.18750 560 18.4 83 1E12N053B 3/18/99

-0.10000

-0.03750

-0.19375

-0.08125

-0.30000

-0.11875

-0.09375

-0.04375

-0.19375 575 18.9 87 1E12N053C 11/4/10

-0.06250

-0.06250

-0.12500

-0.06250

-0.06250

-0.06250

-0.12500

-0.06250 0.00000 542 17.8 89 1E12N053C 5/11/09 0.06250 0.12500 0.18750 0.12500 0.12500 0.06250 0.12500 0.06250 0.00000 602 19.8 91 1E12N053C 9/17/07

-0.18750

-0.12500

-0.06250

-0.06250

-0.06250 0.00000

-0.06250

-0.06250

-0.12500 602 19.8 93 1E12N053C 1/23/06 0.06250 0.00000

-0.06250

-0.06250 0.00000

-0.06250 0.00000 0.00000 0.06250 656 21.6 95 1E12N053C 417104 0.00000

-0.06250

-0.06250

-0.06250

-0.06250

-0.06250

-0.06250

-0.06250 0.00000 630 20.7 97 1E12N053C 7/17/02 0.00000 0.06250 0.06250 0.18750 0.00000 0.06250 0.12500 0.12500 0.00000 631 20.7 99 1E12N053C 10/24/00 0.00000

-0.06250

-0.06250

-0.18750 0.00000

-0.06250

-0.12500

-0.18750 0.00000 586 19.3 101 1E12N053C 3/18/99

-0.08125

-0.13125 0.01250

-0.13750

-0.12500 0.16250

-0.12500 0.05625

-0.11250 575 18.9 105 1E12N055A 12/22109 0.12500 0.18750 0.18750 0.18750 0.06250 0.18750 0.12500 0.18750 0.12500 540 17.7 107 1E12N055A 6/30/08

-0.06250

-0.06250

-0.06250

-0.12500

-0.06250

-0.12500

-0.06250

-0.12500

-0.06250 655 21.5 109 1E12N055A 9/14/06 0.00000 0.06250 0.00000 0.12500 0.06250 0.12500 0.06250 0.06250 0.00000 605 19.9 111 1E12N055A 1/17/05

-0.06250

-0.12500

-0.12500

-0.25000

-0.12500

-0.18750

-0.18750

-0.12500 0.06250 502 16.5 113 1E12N055A 9/3/03

-0.06250

-0.06250

-0.12500

-0.06250

-0.12500

-0.06250

-0.06250

-0.12500

-0.12500 544 17.9 115 1E12N055A 3/8/02

-0.06250 0.12500 0.00000 0.12500 0.18750

-0.06250

-0.12500 0.12500

-0.12500 520 17.1 117 1E12N055A 10/4/00

-0.08125 0.03125 0.18750 0.29375 0.27500 0.28125 0.23125 0.40625

-0.05625 542 17.8 119 1E12N055A 4/11/99 0.05625 0.00000 0.05000 0.03125 0.10000 0.02500

-0.05000

-0.23125 0.01250 589 19.4 123 1E12N055B 1/21/10 0.00000 0.12500 0.12500 0.06250

-0.06250 0.06250 0.12500 0.12500 0.00000 602 19.8 125 1E12N055B 5129/08

-0.06250

-0.06250

-0.06250

-0.12500

-0.06250

-0.12500

-0.06250

-0.06250

-0.06250 547 18.0 127 1E12N055B 11/29/06

-0.12500

-0.25000

-0.18750

-0.25000

-0.25000

-0.25000

-0.25000

-0.25000

-0.12500 558 18.3 129 1E12N055B 5/20/05

-0.06250

-0.06250

-0.06250

-0.06250

-0.12500

-0.06250 0.00000 0.00000

-0.06250 548 18.0 131 1E12N055B 11/19/03 0.06250

-0.18750

-0.25000

-0.31250

-0.25000

-0.25000

-0.18750

-0.18750 0.00000 533 17.5 133 1E12N055B 6/4/02 0.00000

-0.06250 0.06250

-0.12500

-0.31250 0.00000 0.12500 0.06250 0.00000 546 17.9 135 1E12N055B 12/5/00 0.00000

-0.06250

-0.22500

-0.10625 0.13125

-0.28125

-0.23125

-0.24375

-0.00625 559 18.4 137 1E12N055B 5126/99 0.12500 0.06250 0.16250 0.16875

-0.19375 0.28125 0.10625 0.24375 0.06875 587 19.3 141 1E12N055C 1/20/10 0.00000 0.12500 0.12500 0.12500 0.12500 0.12500 0.12500 0.18750 0.00000 601 19.7 143 1E12N055C 5/29/08 0.18750

-0.06250

-0.06250 0.00000 0.00000 0.00000

-0.06250

-0.06250 0.18750 547 18.0 145 1E12N055C 11/29/06

-0.50000

-0.31250

-0.37500

-0.43750

-0.37500

-0.43750

-0.43750

-0.18750

-0.43750 558 18.3 147 1E12N055C 5/20/05

-0.06250 0.00000 0.00000

-0.06250

-0.06250

-0.06250

-0.06250

-0.06250

-0.06250 548 18.0 149 1E12N055C 11/19/03 0.06250 0.00000 0.00000 0.06250 0.18750 0.06250 0.06250 0.06250 0.06250 504 16.6 151 1E12N055C 7/3/02 0.00000

-0.06250

-0.12500

-0.06250

-0.06250

-0.06250

-0.06250

-0.06250

-0.06250 574 18.9

DRIFT ANALYSIS ENGINEERING DEPARTMENT GRAND GULF NUCLEAR STATION Rosemount Range Codes 5 - 8 Gage Pressure Transmitters AF-AL Data JC-Q1111-09019 Rev. 0 Page 93 of 134 DRIFT (% Span) =(Current Cal AF Data - Prev Cal AL Data)

CAL INTERVAL=(Current SeQ.

Date* Previous Date) 10 Tag 10 Cal Date 1

2 3

4 5

6 7

8 9

Days Months (0"/0 Up)

(25% Up)

(50% Up)

(75% Up)

(100% Up)

(75% On)

(50% On)

(25% On)

(0% On) 153 1E12N055C 12/6/00

-0.06250

-0.12500

-0.18750

-0.12500

-0.12500

-0.18750

-0.37500

-0.12500 0.00000 559 18.4 155 1E12N055C 5/27/99 0.06250 0.18750 0.37500 0.25000 0.12500 0.31250 0.43750 0.25000 0.00000 588 19.3 159 1E12N056A 12/21/09 0.12500 0.12500 0.12500 0.12500 0.12500 0.12500 0.06250 0.12500 0.12500 539 17.7 161 1E12N056A 6/30/08

-0.31250

-0.31250

-0.31250

-0.31250

-0.31250

-0.31250

-0.31250

-0.31250

-0.25000 654 21.5 163 1E12N056A 9/15/06

-0.12500 0.06250 0.06250 0.12500 0.00000 0.06250 0.00000 0.00000

-0.12500 606 19.9 165 1E12N056A 1/17/05 0.06250 0.00000

-0.06250

-0.12500

-0.06250

-0.12500

-0.06250 0.06250 0.00000 530 17.4 167 1E12N056A 8/6/03

-0.06250

-0.12500 0.06250

-0.06250 0.06250 0.00000 0.12500

-0.06250

-0.06250 544 17.9 169 1E12N056A 218/02 0.06250

-0.37500

-0.50000

-0.62500

-0.56250

-0.68750

-0.68750

-0.43750

-0.06250 492 16.2 171 1E12N056A 10/4/00 0.03125 0.11250 0.06250 0.14375 0.18125 0.21875 0.18125 0.08750

-0.00625 542 17.8 173 1E12N056A 4/11/99

-0.11875

-0.03750 0.02500 0.01875

-0.05000 0.02500 0.03125

-0.06875

-0.01875 589 19.4 177 1E12N056B 215/10 0.18750 0.37500 0.31250 0.25000 0.18750 0.31250 0.37500 0.37500 0.12500 577 19.0 179 1E12N056B 7/8/08

-0.31250

-0.50000

-0.50000

-0.50000

-0.31250

-0.56250

-0.50000

-0.43750

-0.37500 544 17.9 181 1E12N056B 1/11107

-0.06250 0.00000

-0.06250

-0.06250

-0.25000 0.00000

-0.06250

-0.06250 0.00000 546 17.9 183 1E12N056B 7/14/05 0.06250 0.00000 0.12500 0.12500 0.12500 0.12500 0.12500 0.00000 0.06250 631 20.7 185 1E12N056B 10/22/03

-0.12500

-0.56250 0.00000

-0.75000

-0.87500

-0.81250

-0.68750

-0.50000

-0.12500 547 18.0 187 1E12N056B 4/23/02

-0.06250 0.12500 0.31250 0.68750 0.56250 0.62500 0.25000 0.37500 0.06250 503 16.5 189 1E12N056B 12/6/00 0.04375

-0.08125

-0.15000

-0.35000

-0.09375

-0.26250

-0.07500 0.03750

-0.05625 560 18.4 191 1E12N056B 5/26/99

-0.04375 0.20625 0.27500 0.22500

-0.09375 0.13750 0.32500 0.08750 0.05625 587 19.3 195 1E12N056C 4/6/10

-0.31250

-0.43750

-0.43750

-0.43750

-0.56250

-0.50000

-0.43750

-0.50000

-0.37500 637 20.9 197 1E12N056C 7/8/08

-0.06250 0.00000 0.00000 0.00000 0.12500 0.00000

-0.06250 0.00000 0.00000 545 17.9 199 1E12N056C 1/10/07 0.06250 0.06250 0.06250 0.18750 0.06250 0.18750 0.12500 0.06250 0.00000 560 18.4 201 1E12N056C 6/29/05 0.00000 0.00000

-0.12500

-0.18750

-0.25000

-0.18750

-0.18750

-0.12500 0.00000 616 20.2 203 1E12N056C 10/22/03 0.06250 0.12500 0.06250 0.06250 0.06250 0.06250 0.06250 0.00000 0.06250 476 15.6 205 1E12N056C 7/3/02

-0.12500

-0.18750

-0.06250

-0.12500

-0.12500

-0.12500

-0.12500

-0.06250

-0.12500 574 18.9 207 1E12N056C 12/6/00 0.22500

-0.08750

-0.50625

-0.15625

-0.25625

-0.38125

-0.41875

-0.11875 0.09375 560 18.4 209 1E12N056C 5/26/99

-0.22500

-0.03750 0.38125 0.09375 0.06875 0.25625 0.41875 0.18125

-0.09375 587 19.3 213 1E12N057 2/9/10 0.00000

-0.06250 0.00000

-0.06250

-0.06250

-0.12500

-0.06250

-0.06250

-0.06250 655 21.5 215 1E12N057 4/25/08

-0.06250 0.00000 0.06250 0.06250 0.06250 0.06250 0.12500 0.06250 0.00000 646 21.2 217 1E12N057 7/19/06 0.00000 0.00000

-0.06250

-0.06250

-0.06250

-0.06250

-0.18750

-0.06250 0.00000 545 17.9 219 1E12N057 1/20/05 0.00000 0.12500 0.12500 0.12500 0.06250 0.06250 0.12500 0.12500 0.06250 531 17.4 221 1E12N057 8/8/03 0.00000

-0.06250

-0.12500

-0.06250

-0.06250 0.06250

-0.12500

-0.06250

-0.06250 534 17.5 223 1E12N057 2120/02 0.00000 0.00000 0.06250 0.00000 0.06250

-0.06250 0.12500 0.00000 0.00000 377 12.4 225 1E12N057 2/8/01

-0.12500

-0.18750

-0.12500

-0.25000

-0.25000

-0.18750

-0.31250

-0.18750

-0.18750 557 18.3 227 1E12N057 8/1/99

-0.15000

-0.08750

-0.20625

-0.16250

-0.13750

-0.12500

-0.08125

-0.05000 0.01250 551 18.1

DRIFT ANALYSIS ENGINEERING DEPARTMENT GRAND GULF NUCLEAR STATION Rosemount Range Codes 5 - 8 Gage Pressure Transmitters AF-AL Data JC-Q1111-09019 Rev. 0 Page 94 of 134 DRIFT (% Span) =(Current Cal AF Data* Prev Cal AL Data)

CAL INTERVAL=(Current Seq.

Date - Previous Date) 10 Tag 10 Cal Date 1

2 3

4 5

6 7

8 9

Days Months (0% Up)

(25% Up)

(50% Up)

(75% Up)

(100% Up)

(75% On)

(50% On)

(25% On)

(0% On) 231 1E12N058A 7/12/10

-0.06250

-0.12500

-0.12500

-0.06250

-0.06250 0.00000

-0.18750

-0.12500

-0.06250 670 22.0 233 1E12N058A 9/10/08 0.06250 0.00000 0.06250 0.00000 0.00000 0.00000 0.12500 0.00000 0.06250 603 19.8 235 1E12N058A 1/16/07 0.00000 0.00000

-0.06250 0.00000 0.00000 0.06250 0.00000 0.12500

-0.06250 543 17.8 237 1E12N058A 7/22/05

-0.06250 0.00000 0.00000 0.06250 0.00000 0.00000 0.00000

-0.06250 0.00000 560 18.4 239 1E12N058A 1/9/04 0.00000

-0.12500

-0.18750

-0.31250

-0.37500

-0.25000

-0.06250

-0.18750 0.00000 487 16.0 241 1E12N058A 9/9/02

-0.06250 0.12500 0.06250 0.06250 0.06250 0.00000 0.06250

-0.06250 594 19.5 243 1E12N058A 1/23/01 0.12500 0.00000 0.06250 0.00000 0.18750 0.06250 0.06250 0.06250 0.12500 489 16.1 245 1E12N058A 9/22/99

-0.31250

-0.06250

-0.06250

-0.18750

-0.25000

-0.12500

-0.12500

-0.12500

-0.31250 602 19.8 249 1E12N0588 2119/10 0.00000

-0.12500

-0.18750

-0.12500

-0.06250

-0.12500

-0.18750

-0.25000 0.00000 589 19.4 251 1E12N0588 7/10108

-0.12500 0.00000

-0.06250 0.00000 0.06250 0.00000 0.06250 0.12500 0.12500 547 18.0 253 1E12N0588 1/10/07 0.00000 0.12500 0.18750 0.12500 0.12500 0.12500 0.12500 0.06250 0.00000 560 18.4 255 1E12N0588 6/29/05 0.12500 0.00000

-0.06250

-0.06250

-0.06250

-0.12500

-0.18750

-0.12500 0.00000 532 17.5 257 1E12N0588 1/14/04 0.06250 0.06250 0.06250 0.00000 0.06250 0.18750 0.12500 0.12500 0.12500 545 17.9 259 1E12N0588 7/18/02

-0.18750

-0.06250 0.06250 0.12500

-0.18750

-0.06250 0.12500 0.00000

-0.12500 535 17.6 261 1E12N0588 1/29/01

-0.02500

-0.17500

-0.28750

-0.23125 0.02500

-0.11250

-0.21250

-0.10000 0.00000 529 17.4 263 1E12N0588 8/19/99 0.21250 0.17500 0.16250 0.10625 0.16250 0.05000 0.08750 0.10000 0.12500 591 19.4 267 1E12N058C 2116/10

-0.25000

-0.18750

-0.18750

-0.12500

-0.25000

-0.12500

-0.12500

-0.25000

-0.18750 602 19.8 269 1E12N058C 6/24/08

-0.18750

-0.12500

-0.12500

-0.25000

-0.25000

-0.18750

-0.25000

-0.25000

-0.25000 570 18.7 271 1E12N058C 12/2/06 0.06250 0.00000 0.06250 0.12500 0.06250 0.00000 0.00000 0.06250 0.12500 562 18.5 273 1E12N058C 5/19/05 0.06250 0.06250 0.00000 0.06250 0.06250 0.00000 0.06250 0.00000 0.00000 574 18.9 275 1E12N058C 10/23/03 0.00000

-0.06250

-0.06250

-0.12500

-0.06250 0.06250 0.06250 0.12500 0.12500 462 15.2 277 1E12N058C 7/18/02

-0.12500

-0.12500

-0.06250

-0.18750

-0.37500

-0.25000

-0.31250

-0.25000

-0.12500 535 17.6 279 1E12N058C 1/29/01 0.00000

-0.18750

-0.25000

-0.12500

-0.06250

-0.12500

-0.12500

-0.06250 0.00000 515 16.9 281 1E12N058C 9/2/99 0.18750 0.50000 0.62500 0.62500 0.62500 0.50000 0.87500 0.43750 0.06250 558 18.3 285 1E21N050 8127/10 0.00000 0.06250 0.00000 0.00000 0.06250 0.00000

-0.06250

-0.06250

-0.12500 645 21.2 287 1E21N050 11/20/08 0.06250 0.06250 0.06250 0.12500 0.00000 0.06250 0.00000 0.18750 0.12500 559 18.4 289 1E21N050 5/11/07

-0.06250

-0.06250

-0.12500

-0.18750

-0.12500

-0.12500 0.06250

-0.06250

-0.12500 662 21.7 291 1E21N050 7/18/05 0.00000

-0.06250 0.06250 0.06250 0.06250 0.00000

-0.06250 0.00000 0.06250 643 21.1 293 1E21N050 10/14/03

-0.06250

-0.06250 0.00000 0.00000

-0.18750 0.00000 0.06250 0.00000 0.00000 544 17.9 295 1E21N050 4/18/02

-0.12500

-0.25000

-0.18750

-0.12500

-0.18750

-0.06250

-0.18750

-0.12500

-0.25000 549 18.0 297 1E21N050 10/16/00 0.08125 0.15000 0.03125

-0.05625

-0.02500

-0.08125

-0.01875 0.01875 0.00000 554 18.2 299 1E21N050 4/11/99

-0.08125

-0.21250

-0.15625 0.05625 0.08750 0.01875

-0.04375

-0.08125 0.00000 589 19.4 303 1E21N052 2/8/10

-0.12500 0.00000 0.12500 0.06250 0.06250 0.12500 0.12500 0.00000

-0.12500 627 20.6

DRIFT ANALYSIS ENGINEERING DEPARTMENT GRAND GULF NUCLEAR STATION Rosemount Range Codes 5 - 8 Gage Pressure Transmitters AF-AL Data JC-Q1111-09019 Rev. 0 Page 95 of 134 DRIFT (% Span) = (Current Cal AF Data - Prev Cal AL Data)

CAL INTERVAL" (Current Sea.

Date* Previous Date) 10 Tag ID Cal Date 1

2 3

4 5

6 7

8 9

Days Months (0% Up)

(25% Up)

(50% Up)

(75% Up)

(100% Up)

(75% On)

(50% On)

(25% On)

(0% On) 305 1E21N052 5/22/08

-0.37500

-0.50000

-0.37500

-0.50000

-0.50000

-0.50000

-0.43750

-0.50000

-0.37500 559 18.4 307 1E21N052 11/10/06 0.06250 0.06250

-0.12500

-0.12500

-0.06250

-0.12500

-0.06250

-0.06250 0.06250 577 19.0 309 1E21N052 4/12/05

-0.43750

-0.31250

-0.31250

-0.31250

-0.31250

-0.37500

-0.31250

-0.31250

-0.31250 657 21.6 311 1E21N052 6125/03 0.12500 0.68750 0.75000 1.37500 1.87500 1.37500 0.68750 0.62500 0.18750 532 17.5 313 1E21N052 1/9/02 0.12500 0.06250

-0.43750

-0.81250

-1.37500

-0.93750

-0.56250 0.00000 0.25000 486 16.0 315 1E21N052 9/10/00

-0.31250

-0.31250

-0.31250

-0.31250

-0.37500

-0.31250

-0.31250

-0.25000

-0.37500 550 18.1 317 1E21N052 3110/99 0.05625

-0.20625

-0.23125

-0.21250

-0.10625

-0.11875

-0.18750

-0.24375 0.05000 562 18.5 321 1E21N053 8/10/09

-0.12500 0.00000

-0.06250

-0.06250

-0.06250 0.00000

-0.06250

-0.06250

-0.06250 543 17.8 323 1E21N053 2/14/08 0.12500

-0.06250 0.00000

-0.12500 0.06250

-0.12500 0.06250 0.00000 0.12500 548 18.0 325 1E21N053 8115/06 0.06250 0.12500 0.00000 0.18750

-0.18750 0.18750 0.00000 0.06250 0.06250 570 18.7 327 1E21N053 1/22/05

-0.12500

-0.12500 0.00000

-0.12500 0.12500

-0.12500

-0.06250

-0.06250

-0.12500 550 18.1 329 1E21N053 7/22/03 0.00000 0.06250 0.37500 0.87500 1.25000 0.87500 0.37500 0.00000 0.00000 558 18.3 331 1E21N053 1/10/02

-0.31250 0.12500 0.25000 0.12500 0.25000 0.18750 0.25000 0.18750

-0.25000 487 16.0 333 1E21N053 9/10/00

-0.41875

-0.62500

-0.62500

-0.81250

-0.87500

-0.75000

-0.75000

-0.62500

-0.36875 549 18.0 335 1E21N053 3/11/99 0.08125

-0.11250

-0.08750 0.05000 0.01250 0.16250 0.00000 0.00625 0.00625 563 18.5 339 1E21N054 9/24/10

-0.12500 0.06250 0.06250

-0.06250

-0.25000

-0.25000 0.00000 0.12500

-0.06250 673 22.1 341 1E21N054 11/20/08 1.00000 0.50000 0.37500 0.37500 0.00000 0.25000 0.37500 0.50000 1.00000 563 18.5 343 1E21N054 517107 0.00000 0.00000 0.00000 0.00000

-0.06250 0.00000 0.00000 0.00000

-0.06250 644 21.2 345 1E21N054 811105 0.00000 0.12500

-0.06250

-0.18750

-0.06250 0.06250 0.06250 0.12500 0.00000 601 19.7 347 1E21N054 12/9/03

-0.06250

-0.18750

-0.06250 0.06250

-0.12500

-0.06250 0.06250 0.00000 0.00000 516 17.0 349 1E21N054 7/11/02 0.06250 0.06250 0.06250 0.06250 0.12500 0.06250

-0.06250

-0.06250 0.06250 534 17.5 351 1E21N054 1/23/01

-0.08750

-0.06250

-0.04375 0.05000 0.04375

-0.06250

-0.08750

-0.06875

-0.09375 561 18.4 353 1E21N054 7/12/99 0.08750 0.00000 0.10625

-0.11250

-0.16875

-0.12500 0.02500 0.00625 0.09375 543 17.8 357 1E22N050 3119/10

-0.12500

-0.18750

-0.25000

-0.25000

-0.25000

-0.25000

-0.18750 630 20.7 359 1E22N050 6127108

-0.12500

-0.12500

-0.06250

-0.06250

-0.06250

-0.06250

-0.12500 590 19.4 361 1E22N050 11/15/06

-0.06250

-0.06250

-0.12500

-0.31250

-0.18750

-0.12500

-0.18750 530 17.4 363 1E22N050 6/3/05

-1.56250

-0.43750

-1.00000

-0.68750

-0.93750

-1.50000

-1.12500 616 20.2 365 1E22N050 9/26/03

-0.81250

-0.62500

-0.50000

-0.62500

-0.56250

-0.62500

-0.75000 532 17.5 367 1E22N050 4/12/02

-0.43750

-0.31250

-0.25000

-0.12500

-0.18750 0.06250

-0.31250 504 16.6 369 1E22N050 11/24/00 0.62500 0.37500 0.25000 0.25000 0.12500 0.06250 0.18750 602 19.8 371 1E22N050 4/2/99 0.15000

-0.18750

-0.15625

-0.32500 0.08750

-0.01250

-0.15000 574 18.9 375 1E22N054C 4/2/10 0.06250 0.12500 0.18750 0.12500 0.12500 0.12500 0.12500 0.12500 0.06250 672 22.1 377 1E22N054C 5/30108 0.12500 0.18750 0.12500 0.12500 0.18750 0.12500 0.12500 0.12500 0.12500 504 16.6

DRIFT ANALYSIS ENGINEERING DEPARTMENT GRAND GULF NUCLEAR STATION Rosemount Range Codes 5 - 8 Gage Pressure Transmitters AF-AL Data JC-Q1111-09019 Rev. 0 Page 96 of 134 DRIFT (% Span) = (Current Cal AF Data - Prev Cal AL Data)

CAL INTERVAL =(Current Seq.

Date* Previous Date) 10 Tag ID Cal Date 1

2 3

4 5

6 7

8 9

Days Months (0% Up)

(25% Up)

(50% Up)

(75% Up)

(100% Up)

(75% On)

(50% On)

(25% On)

(0% On) 381 1E22N054G 11/20/09 0.06250 0.06250 0.00000 0.06250 0.12500 0.18750 0.12500 0.12500 0.12500 539 17.7 383 1E22N054G 5/30/08 0.00000 0.00000 0.00000 0.00000

-0.06250 0.00000 0.00000 0.06250 0.00000 588 19.3 387 1E31N085A 5/12/10 0.12500 0.06250 0.00000 0.00000 0.00000 0.06250 0.00000 0.00000 0.12500 589 19.4 389 1E31N085A 9/30/08

-0.12500

-0.18750

-0.18750

-0.12500

-0.18750

-0.18750

-0.25000

-0.18750

-0.25000 547 18.0 391 1E31N085A 4/2/07

-0.12500 0.06250

-0.06250 0.00000 0.00000 0.00000 0.00000 0.06250 0.00000 551 18.1 393 1E31N085A 9/28/05 0.06250

-0.12500

-0.25000

-0.25000

-0.50000

-0.25000

-0.18750 0.00000 0.12500 572 18.8 395 1E31N085A 3/5/04

-0.12500

-0.06250 0.00000

-0.12500

-0.12500

-0.12500

-0.06250

-0.06250

-0.37500 529 17.4 397 1E31N085A 9/23/02

-0.12500

-0.12500

-0.18750

-0.12500 0.12500

-0.12500

-0.18750

-0.12500 0.12500 517 17.0 399 1E31N085A 4/24/01 0.75000 1.00000 1.00000 1.12500 0.93750 1.18750 1.06250 1.00000 0.75000 537 17.6 401 1E31N085A 11/4/99

-1.37500

-1.56250

-1.56250

-1.70000

-1.75000

-1.63125

-1.64375

-1.48750

-1.19375 559 18.4 405 1E31N085B 5/4/10

-0.31250

-0.43750

-0.56250

-0.62500

-0.50000

-0.56250

-0.62500

-0.56250

-0.37500 581 19.1 407 1E31 N085B 9/30/08

-0.12500

-0.12500

-0.06250 0.00000

-0.06250 0.00000 0.00000 0.06250

-0.06250 548 18.0 409 1E31N085B 4/1/07 0.25000 0.56250 0.62500 0.62500 0.56250 0.43750 0.43750 0.50000 0.25000 551 18.1 411 1E31 N085B 9/27/05

-0.06250

-0.37500

-0.25000

-0.37500

-0.50000

-0.31250

-0.25000

-0.18750 0.06250 572 18.8 413 1E31N085B 3/4/04 9.31250 11.37500 11.12500 10.56250 9.75000 11.06250 11.06250 11.00000 12.43750 528 17.3 415 1E31N085B 9/23/02

-0.18750 0.12500 0.43750 0.68750 1.25000 1.18750 0.62500 0.18750

-0.12500 522 17.1 417 1E31N085B 4/19/01 0.62500 0.37500 0.00000

-0.37500

-0.68750

-0.37500 0.00000 0.37500 0.62500 519 17.1 419 1E31N085B 11/17/99

-0.68125

-0.66875

-1.06875

-1.00625

-1.07500

-0.93750

-0.90625

-0.75625

-0.48125 572 18.8 423 1E32N050 5/4/10 0.00000 0.00000

-0.06250

-0.06250 0.00000 0.00000 0.00000 0.00000 0.00000 577 19.0 425 1E32N050 10/4/08

-0.06250 0.12500 0.12500 0.12500 0.18750 0.12500 0.18750 0.12500

-0.06250 549 18.0 427 1E32N050 4/4/07 0.37500 0.06250 0.12500 0.06250 0.12500 0.18750 0.18750 0.25000 0.25000 552 18.1 429 1E32N050 9/29/05

-0.37500

-0.12500

-0.18750

-0.06250

-0.18750

-0.18750

-0.31250

-0.37500

-0.25000 571 18.8 433 1E32N050 9/28/02 0.00000 0.12500 0.06250 0.06250 0.06250 0.06250 0.06250 0.25000 0.12500 513 16.9 435 1E32N050 5/3/01

-2.37500

-2.25000

-2.25000

-2.25000

-2.12500

-2.18750

-2.06250

-2.18750

-2.50000 544 17.9 437 1E32N050 11/6/99 1.37500 0.93750 0.18750

-0.68750

-1.56250

-0.75000 0.18750 0.81250 1.43750 159 5.2 439 1E32N050 5/31/99 0.06875 1.05625 1.56250 2.68750 3.54375 2.68750 1.43750 0.99375

-0.11875 602 19.8 443 1E32N055 7/8/09 0.06250

-0.06250

-0.06250

-0.06250

-0.12500

-0.06250 0.00000

-0.06250 0.00000 548 18.0 445 1E32N055 117108

-0.06250 0.12500 0.12500 0.25000 0.25000 0.18750 0.18750 0.12500 0.00000 642 21.1 447 1E32N055 4/5/06 0.00000 0.00000 0.12500 0.00000 0.00000 0.00000 0.00000 0.06250 0.06250 546 17.9 449 1E32N055 10/6/04

-0.12500

-0.18750

-0.25000

-0.18750

-0.18750

-0.25000

-0.12500

-0.18750

-0.06250 533 17.5 451 1E32N055 4/22/03 0.25000 0.18750 0.06250 0.18750 0.25000 0.25000 0.06250 0.12500 0.25000 519 17.1 453 1E32N055 11/19/01 0.31250

-0.06250 0.06250

-0.18750

-0.37500

-0.25000

-0.12500

-0.12500 0.18750 459 15.1 455 1E32N055 8/17/00 0.00000

-0.18750

-0.37500

-0.37500

-0.18750

-0.18750

-0.25000

-0.18750 0.06250 548 18.0

DRIFT ANALYSIS ENGINEERING DEPARTMENT GRAND GULF NUCLEAR STATION Rosemount Range Codes 5 - 8 Gage Pressure Transmitters AF-AL Data JC-Q1111-09019 Rev. 0 Page 97 of 134 DRIFT (% Span) =(Current Cal AF Data* Prev Cal AL Data)

CAL INTERVAL=(Current Seq.

Date - Previous Date) 10 Tag 10 Cal Date 1

2 3

4 5

6 7

8 9

Days Months (0% Up)

(25% Up)

(50% Up)

(75°A. Up)

(100% Up)

(75% On)

(50% On)

(25% On)

(O°A. On) 457 1E32N055 2116/99 0.12500

-0.06250 0.06250 0.06250 0.00000

-0.06250 0.12500

-0.06250

-0.12500 546 17.9 461 1E32N058 4/30/10

-0.06250

-0.06250

-0.12500

-0.18750

-0.25000

-0.18750

-0.12500

-0.06250

-0.06250 575 18.9 463 1E32N058 10/2/08 0.06250 0.00000 0.00000 0.00000 0.00000 0.00000 0.06250 0.00000 0.06250 557 18.3 465 1E32N058 3/25/07

-0.06250 0.06250 0.12500 0.18750 0.25000 0.18750 0.06250 0.06250

-0.06250 549 18.0 467 1E32N058 9/22/05 0.00000 0.00000 0.00000 0.00000 0.06250 0.00000 0.00000

-0.06250 0.00000 566 18.6 471 1E32N058 9/15/02

-0.62500

-0.50000

-0.43750

-0.62500

-0.56250

-0.62500

-0.56250

-0.50000

-0.62500 510 16.8 477 1E32N058 6/21/99 0.87500 1.87500 2.75000 3.56250 4.43750 3.56250 2.62500 2.00000 0.93750 601 19.7 481 1E32N061A 8112/09 0.06250 0.06250 0.00000 0.00000 0.00000 0.06250 0.00000 0.06250 0.06250 544 17.9 483 1E32N061A 2115/08

-0.06250

-0.06250 0.00000 0.00000 0.00000

-0.06250 0.00000

-0.06250

-0.06250 536 17.6 485 1E32N061A 8128/06 0.06250 0.06250 0.00000 0.00000 0.00000 0.00000 0.00000 0.06250 0.06250 598 19.6 489 1E32N061A 5/13/03

-0.31250

-0.31250

-0.43750

-0.37500

-0.31250

-0.31250

-0.43750

-0.37500

-0.31250 533 17.5 491 1E32N061A 11/26/01

-0.06250 0.06250 0.37500 0.50000 0.50000 0.37500 0.37500 0.00000

-0.06250 420 13.8 493 1E32N061A 10/2/00

-0.25000

-0.18750

-0.31250

-0.62500

-0.68750

-0.62500

-0.43750

-0.18750

-0.18750 542 17.8 495 1E32N061A 4/9/99 0.31250 0.00000 0.00000 0.00000 0.06250 0.06250 0.12500 0.12500 0.18750 548 18.0 499 1E32N061E 11/2/09

-0.06250

-0.06250 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000

-0.06250 642 21.1 501 1E32N061E 1/30/08

-0.06250

-0.06250

-0.06250 0.00000

-0.06250 0.00000 0.00000

-0.06250

-0.06250 656 21.6 503 1E32N061E 4/14/06 0.06250 0.12500 0.12500 0.12500 0.25000 0.12500 0.12500 0.12500 0.06250 533 17.5 507 1E32N061E 5/28/03

-0.43750

-0.50000

-0.56250

-0.56250

-0.50000

-0.50000

-0.50000

-0.50000

-0.43750 546 17.9 509 1E32N061E 11/28/01

-0.31250

-0.31250

-0.43750

-0.50000

-0.50000

-0.50000

-0.43750

-0.31250

-0.31250 363 11.9 511 1E32N061E 11/30/00 0.12500 0.31250 0.43750 0.50000 0.37500 0.37500 0.50000 0.25000 0.25000 601 19.7 513 1E32N061E 4/9/99

-0.31250

-0.18750

-0.37500

-0.43750

-0.25000

-0.25000

-0.37500

-0.37500

-0.25000 548 18.0 517 1E32N061J 5/5/09

-0.25000

-0.25000

-0.25000

-0.18750

-0.18750

-0.18750

-0.12500

-0.18750

-0.12500 543 17.8 519 1E32N061J 11/9/07 0.06250 0.12500 0.18750 0.12500 0.06250 0.06250 0.06250 0.06250 0.00000 547 18.0 521 1E32N061J 5111/06

-0.06250

-0.12500

-0.06250

-0.12500

-0.18750

-0.18750

-0.18750

-0.06250

-0.06250 589 19.4 525 1E32N061J 4/3/03

-0.12500 0.00000 0.00000 0.00000 0.06250 0.06250 0.00000 0.00000

-0.12500 507 16.7 527 1E32N061J 11/12/01

-0.12500

-0.18750

-0.25000

-0.12500 0.12500

-0.12500

-0.12500

-0.18750

-0.31250 476 15.6 529 1E32N061J 7/24/00 0.62500 0.50000 0.56250 0.56250 0.56250 0.50000 0.56250 0.62500 0.75000 544 17.9 531 1E32N061J 1/27/99 0.06250 0.00000 0.06250 0.12500 0.18750 0.18750 0.18750 0.12500 0.06250 560 18.4

DRIFT ANALYSIS ENGINEERING DEPARTMENT GRAND GULF NUCLEAR STATION Rosemount Range Codes 5 - 8 Gage Pressure Transmitters AF-AL Data JC-Q1111-09019 Rev. 0 Page 98 of 134 DRIFT (% Span) =(Current Cal AF Data - Prev Cal AL Data)

CAL INTERVAL=(Current Seq.

Date* Previous Date) 10 Tag 10 Cal Date 1

2 3

4 S

6 7

8 9

Days Months (0% Up)

(2S% Up)

(SO% Up)

(7SDk Up)

(100% Up)

(7S%Dn)

(SODk On)

(2SDk On)

(0% On) 535 1E32N061N 12/8/09 0.00000

-0.06250 0.00000 0.06250

-0.06250 0.00000 0.00000 0.00000 0.00000 540 17.7 537 1E32N061N 6/16/08 0.00000 0.00000 0.00000

-0.06250 0.00000 0.00000

-0.06250 0.00000 0.00000 658 21.6 539 1E32N061N 8/28/06 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.06250 0.00000 598 19.6 543 1E32N061N 5/16/03

-0.50000

-0.50000

-0.50000

-0.37500

-0.25000

-0.31250

-0.43750

-0.43750

-0.50000 550 18.1 545 1E32N061N 11/12/01

-0.18750

-0.25000

-0.12500

-0.06250 0.00000

-0.06250

-0.12500

-0.12500

-0.31250 406 13.3 547 1E32N061N 10/2/00 0.41250 0.36250

-0.08125

-0.29375

-0.26875

-0.25000 0.00625 0.23750 0.36250 541 17.8 549 1E32N061N 4/10/99

-0.10000

-0.30000

-0.16875 0.10625 0.08125 0.06250

-0.13125

-0.05000 0.13750 550 18.1 553 1E51N035A 4/24/10 0.00000

-0.06250

-0.06250

-0.06250

-0.06250 0.06250 0.06250 0.00000

-0.06250 661 21.7 555 1E51N035A 7/2/08

-0.06250 0.00000

-0.06250

-0.06250 0.06250 0.00000

-0.12500 0.00000 0.00000 152 5.0 557 1E51N035A 2/1/08

-0.06250

-0.06250 0.00000 0.00000

-0.12500 0.00000 0.06250 0.00000 0.06250 545 17.9 561 1E51N035E 4/25/10 0.18750 0.06250 0.00000 0.00000 0.00000 0.06250 0.00000 0.12500 0.18750 664 21.8 563 1E51N035E 6/30/08 0.06250 0.06250 0.06250 0.12500 0.06250 0.06250 0.12500 0.00000

-0.06250 631 20.7 567 1E51N055A 6/29/09 0.06250 0.00000 0.00000

-0.06250

-0.12500 0.00000 0.00000 0.00000 0.06250 544 17.9 569 1E51 N055A 1/2/08 0.00000 0.00000

-0.06250

-0.12500

-0.06250

-0.12500

-0.12500

-0.06250 0.00000 655 21.5 571 1E51 N055A 3/18/06

-0.06250 0.00000 0.06250 0.12500 0.12500 0.12500 0.12500 0.06250 0.00000 591 19.4 573 1E51 N055A 8/4/04 0.06250 0.00000 0.00000 0.00000 0.06250 0.00000 0.00000 0.00000 0.00000 532 17.5 575 1E51 N055A 2119/03 0.00000

-0.06250

-0.06250

-0.12500

-0.12500

-0.12500

-0.06250

-0.06250 0.00000 666 21.9 577 1E51 N055A 4/24/01

-0.12500

-0.18750

-0.12500

-0.12500 0.00000

-0.06250

-0.12500

-0.12500

-0.12500 543 17.8 579 1E51 N055A 10/29/99 0.06250 0.12500 0.00000 0.00000

-0.12500

-0.06250 0.00000 0.06250 0.06250 557 18.3 583 1E51N055B 11/4/10

-0.06250

-0.06250

-0.06250

-0.12500

-0.12500

-0.12500

-0.06250

-0.06250

-0.06250 651 21.4 585 1E51N055B 1/22/09 0.06250 0.06250 0.06250 0.06250 0.00000 0.06250 0.06250 0.06250 0.06250 531 17.4 587 1E51 N055B 8/10/07 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 547 18.0 589 1E51N055B 219/06 0.00000 0.00000 0.00000

-0.06250

-0.12500

-0.06250 0.00000 0.00000

-0.06250 646 21.2 591 1E51N055B 5/4/04 0.00000

-0.06250

-0.06250 0.00000 0.00000

-0.06250

-0.06250

-0.06250 0.00000 531 17.4 593 1E51N055B 11/20/02 0.00000 0.00000 0.12500 0.00000 0.06250 0.06250 0.12500 0.06250 0.00000 579 19.0 595 1E51 N055B 4/20/01 0.00000 0.06250

-0.12500

-0.06250

-0.06250

-0.06250

-0.06250 0.00000 0.06250 521 17.1 597 1E51N055B 11/16/99

-0.06250 0.00000 0.00000 0.00000 0.00000 0.00000

-0.06250

-0.06250 0.00000 575 18.9 601 1E51N055E 2126/10

-0.06250

-0.06250

-0.06250

-0.06250

-0.06250

-0.06250

-0.06250 0.06250

-0.06250 603 19.8 603 1E51N055E 7/3/08 0.00000 0.00000

-0.06250 0.00000 0.12500 0.00000 0.06250 0.00000 0.00000 632 20.8

DRIFT ANALYSIS ENGINEERING DEPARTMENT GRAND GULF NUCLEAR STATION Rosemount Range Codes 5 - 8 Gage Pressure Transmitters AF-AL Data JC-Q1111-09019 Rev. 0 Page 99 of 134 DRIFT (% Span) = (Current Cal AF Data* Prev Cal AL Data)

CAL INTERVAL = (Current Seq.

Date* Previous Date) 10 Tag 10 Cal Date 1

2 3

4 5

6 7

8 9

Days Months (0% Up)

(25% Up)

(50°,{, Up)

(75% Up)

(100% Up)

(750/0 On)

(50% On)

(25% On)

(0% On) 605 1E51N055E 10/10/06 0.06250 0.00000 0.06250 0.00000

-0.06250 0.06250 0.06250 0.06250 0.06250 658 21.6 607 1E51N055E 12/21/04 0.06250 0.06250 0.06250 0.06250 0.12500 0.00000

-0.06250 0.00000 0.06250 671 22.0 609 1E51N055E 2119/03

-0.12500

-0.18750

-0.25000

-0.18750

-0.31250

-0.18750

-0.18750

-0.18750

-0.12500 665 21.8 611 1E51N055E 4/25/01 0.00000 0.06250 0.12500

-0.06250 0.18750 0.06250 0.12500 0.12500 0.06250 544 17.9 613 1E51N055E 10/29/99 0.12500 0.06250 0.06250 0.12500

-0.06250 0.00000

-0.06250 0.00000 0.06250 557 18.3 617 1E51N055F 6/9/09 0.00000

-0.06250

-0.12500

-0.06250

-0.06250

-0.06250

-0.06250 0.00000 0.00000 628 20.6 619 1E51 N055F 9/20/07 0.00000 0.06250 0.12500 0.06250 0.06250 0.06250 0.12500 0.06250 0.06250 604 19.8 621 1E51N055F 1/24/06 0.12500 0.06250 0.00000 0.06250 0.06250 0.06250 0.00000 0.00000 0.06250 628 20.6 623 1E51N055F 5/6/04

-0.12500

-0.06250 0.00000

-0.06250 0.00000

-0.06250 0.00000 0.00000

-0.06250 532 17.5 625 1E51N055F 11/21/02 0.12500 0.00000 0.00000 0.00000

-0.12500 0.06250 0.06250 0.06250 0.00000 580 19.1 627 1E51N055F 4/20/01

-0.06250 0.06250 0.06250 0.00000 0.06250

-0.06250 0.00000 0.00000 0.06250 521 17.1 629 1E51N055F 11/16/99 0.00000 0.12500 0.18750 0.25000 0.25000 0.25000 0.18750 0.12500 0.00000 575 18.9

DRIFT ANALYSIS ENGINEERING DEPARTMENT GRAND GULF NUCLEAR STATION Rosemount Range Codes 5 - 8 Gage Pressure Transmitters Outliers &Summary JC-Q1111-09019 Rev. 0 Page 100 of 134 Drift(Pt 1)

Drift (Pt 2)

Drift (Pt 3)

Drift (Pt4)

Drift (Pt 5)

Drift (Pt 6)

Drift (Pt 7)

Drift (Pt 8)

Drift (Pt9)

Cal Interval Seq. 10 Tag 10 (0% Up)

(25% Up)

(50% Up)

(75% Up)

(100"10 Up)

(75% On)

(50% On)

(25"10 On)

(O%Dn)

(Days)

(%Span)

(%Span)

("IoSpan)

(%~pan)

(%Span)

(%Span)

(%Span)

(%Span)

(%Span) 1 1B21N201A 0.00000 0.00000 0.00000 0.06250 0.06250 0.06250 0.06250 0.00000 0.00000 659 3

1B21N201A 0.06250 0.06250 0.00000

-0.06250

-0.12500

-0.06250 0.00000 0.06250 0.06250 658 5

1B21N201A 0.00000 0.18750 0.31250 0.56250 1.18750 0.68750 0.31250 0.25000

-0.06250 546 7

1B21N201A 0.00000 0.06250 0.12500 0.18750 0.18750 0.12500 0.06250 0.06250 0.06250 533 9

1B21N201A

-0.06250 0.18750 0.12500 0.06250 0.06250 0.12500 0.18750 0.25000

-0.12500 580 11 1B21N201A 0.45000 0.06250

..().19375

..().13750

-0.01250

..().05625

-0.08125 0.08125 0.43125 544 13 1B21N201A

-0.07500

..().06250 0.13125 0.07500

-0.05000 0.11875 0.08125

-0.08125

-0.05625 555 17 1B21N201B 0.06250 0.06250 0.00000 0.00000 0.00000 0.00000 0.00000 0.06250 0.06250 612 19 1B21N201B 0.00000 0.06250

..().02500 0.06250 0.00000 0.00000 0.00000 0.06250 0.00000 536 21 1B21N201B 0.00000 0.00000 0.00000

..().12500 0.06250

..().06250 0.00000

-0.06250 0.00000 583 23 1B21N201B 0.00000

..().0625O

..().03750 0.00000

-0.12500 0.00000

-0.06250

-0.06250 0.00000 601 25 1B21N201B 0.00000 0.18750 0.06250 0.25000 0.25000 0.25000 0.18750 0.25000 0.12500 630 27 1B21N201B 0.06250

..().12500 0.00000

-0.18750

-0.18750

-0.18750

-0.12500

-0.12500

-0.06250 549 29 1B21N201B 0.00000 0.00000 0.06250 0.12500 0.00000 0.00000

-0.12500

-0.06250

-0.06250 535 31 1B21N201B 0.06250 0.06250

-0.12500

..().18750

-0.06250 0.00000 0.06250 0.12500 0.06250 568 35 1C61N102 0.06250 0.00000

..().06250 0.00000

-0.12500

..().06250

-0.06250 0.00000 0.06250 544 37 1C61N102 0.12500 0.12500 0.12500 0.06250 0.06250 0.06250 0.06250 0.18750 0.12500 533 39 1C61N102 0.06250 0.06250 0.12500 0.12500 0.12500 0.18750 0.12500 0.06250 0.06250 589 41 1C61N102

..().25000

..().18750

..().18750

-0.12500

-0.06250

..().12500

-0.18750

-0.25000

-0.25000 531 43 1C61N102 0.00000

..().06250

..().06250

..().06250

-0.06250

..().06250 0.00000 0.00000 0.00000 545 45 1C61N102 0.12500 0.12500 0.00000 0.12500 0.12500 0.12500 0.06250 0.12500 0.06250 542 47 1C61N102

-0.18750

..().06250 0.06250

-0.06250

-0.06250 0.00000 0.06250 0.00000

-0.12500 505 51 1E12N053A 0.00000 0.00000 0.06250 0.06250 0.06250 0.00000 0.06250 0.06250

-0.06250 544 53 1E12N053A

..().12500

..()06250

-0.18750

-0.12500

-0.12500

..().12500

-0.06250

-0.06250

-0.06250 534 55 1E12N053A 0.00000 0.00000 0.12500 0.06250 0.06250 0.06250 0.00000

-0.06250 0.00000 531 57 1E12N053A 0.00000 0.00000

..().06250

..().06250

-0.06250

..().06250

-0.06250 0.00000 0.06250 531 59 1E12N053A

..().06250

..().18750

-0.18750

-0.18750

-0.18750

..().18750

-0.18750

-0.12500

-0.06250 534 61 1E12N053A

-0.06250 0.06250

..().06250 0.00000

-0.06250 0.06250 0.00000 0.06250

-0.06250 548 63 1E12N053A 0.06250 0.00000 0.00000

..().06250 0.12500 0.00000 0.06250 0.06250 0.06250 574 65 1E12N053A

-0.11875

..().06250 0.00000

-0.11250 0.17500

..().00625

-0.01875

-0.09375

-0.05625 573 69 1E12N053B

-0.12500

..().06250

..().06250

-0.06250

-0.06250

-0.18750

-0.06250

-0.06250

-0.31250 564 71 1E12N053B

..().25000 0.06250 0.06250 0.06250 0.12500 0.12500 0.06250 0.06250 0.00000 547 73 1E12N053B 0.00000 0.00000

..().06250

..().12500

-0.12500

..().1875O

-0.12500

-0.06250 0.00000 558 75 1E12N053B 0.00000 0.00000 0.06250 0.00000 0.00000 0.00000 0.00000

-0.06250 0.00000 547 77 1E12N0538

..().12500

-0.12500

-0.12500

-0.06250

-0.06250

-0.06250

-0.12500

-0.06250

-0.18750 491 79 1E12N053B 0.00000 0.06250

..().12500

..().12500 0.00000

-0.06250 0.06250 0.06250 0.06250 657 81 1E12N053B 0.12500

-0.12500 0.06250 0.00000

-0.06250

..().06250

-0.12500

-0.12500 0.18750 560 83 1E12N053B

-0.10000

-0.03750

..().19375

..().08125

-0.30000

..().11875

-0.09375

-0.04375

-0.19375 575

DRIFT ANALYSIS ENGINEERING DEPARTMENT GRAND GULF NUCLEAR STATION Rosemount Range Codes 5 - 8 Gage Pressure Transmitters Outliers &Summary JC-Q1111-09019 Rev. 0 Page 101 of 134 Drift (Pt 1)

Drift (Pt 2)

Drift (Pt 3)

Drift (Pt4)

Drift (Pt 5)

Drift (Pt 6)

Drift (Pt 7)

Drift (Pt8)

Drift (Pt 9)

Cal Interval Seq.ID TaglD (0% Up)

(25% Up)

(50% Up)

(75% Up)

(100% Up)

(75% Dn)

(50%Dn)

(25%Dn)

(O%Dn)

(Days)

(%Span)

(%Span)

(%Span)

(%Span)

(%Span)

(%Span)

(%Span)

(%Span)

(%Span) 87 lE12N053C

-0.06250

-0.06250

-0.12500

-0.06250

-0.06250

-0.06250

-0.12500

-0.06250 0.00000 542 89 lE12N053C 0.06250 0.12500 0.18750 0.12500 0.12500 0.06250 0.12500 0.06250 0.00000 602 91 1E12N053C

-0.18750

-0.12500

-0.06250

-0.06250

-0.06250 0.00000

-0.06250

-0.06250

-0.12500 602 93 1E12N053C 0.06250 0.00000

-0.06250

-0.06250 0.00000

-0.06250 0.00000 0.00000 0.06250 656 95 1E12N053C 0.00000

-0.06250

-0.06250

-0.06250

-0.06250

-0.06250

-0.06250

-0.06250 0.00000 630 97 lE12N053C 0.00000 0.06250 0.06250 0.18750 0.00000 0.06250 0.12500 0.12500 0.00000 631 99 1E12N053C 0.00000

-0.06250

-0.06250

-0.18750 0.00000

-0.06250

-0.12500

-0.18750 0.00000 586 101 lE12N053C

-0.08125

-0.13125 0.01250

-0.13750

-0.12500 0.16250

-0.12500 0.05625

-0.11250 575 105 lE12N055A 0.12500 0.18750 0.18750 0.18750 0.06250 0.18750 0.12500 0.18750 0.12500 540 107 lE12N055A

-0.06250

-0.06250

-0.06250

-0.12500

-0.06250

-0.12500

-0.06250

-0.12500

-0.06250 655 109 lE12N055A 0.00000 0.06250 0.00000 0.12500 0.06250 0.12500 0.06250 0.06250 0.00000 605 111 1E12N055A

-0.06250

-0.12500

-0.12500

-0.25000

-0.12500

-0.18750

-0.18750

-0.12500 0.06250 502 113 1E12N055A

-0.06250

-0.06250

-0.12500

-0.06250

-0.12500

-0.06250

-0.06250

-0.12500

-0.12500 544 115 1E12N055A

-0.06250 0.12500 0.00000 0.12500 0.18750

-0.06250

-0.12500 0.12500

-0.12500 520 117 1E12N055A

-0.08125 0.03125 0.18750 0.29375 0.27500 0.28125 0.23125 0.40625

-0.05625 542 119 1E12N055A 0.05625 0.00000 0.05000 0.03125 0.10000 0.02500

-0.05000

-0.23125 0.01250 589 123 lE12N055B 0.00000 0.12500 0.12500 0.06250

-0.06250 0.06250 0.12500 0.12500 0.00000 602 125 1E12N055B

-0.06250

-0.06250

-0.06250

-0.12500

-0.06250

-0.12500

-0.06250

-0.06250

-0.06250 547 127 1E12N055B

-0.12500

-0.25000

-0.18750

-0.25000

-0.25000

-0.25000

-0.25000

-0.25000

-0.12500 558 129 1E12N055B

-0.06250

-0.06250

-0.06250

-0.06250

-0.12500

-0.06250 0.00000 0.00000

-0.06250 548 131 lE12N055B 0.06250

-0.18750

-0.25000

-0.31250

-0.25000

-0.25000

-0.18750

-0.18750 0.00000 533 133 1E12N055B 0.00000

-0.06250 0.06250

-0.12500

-0.31250 0.00000 0.12500 0.06250 0.00000 546 135 1E12N055B 0.00000

-0.06250

-0.22500

-0.10625 0.13125

-0.28125

-0.23125

-0.24375

-0.00625 559 137 1E12N055B 0.12500 0.06250 0.16250 0.16875

-0.19375 0.28125 0.10625 0.24375 0.06875 587 141 1E12N055C 0.00000 0.12500 0.12500 0.12500 0.12500 0.12500 0.12500 0.18750 0.00000 601 143 1E12N055C 0.18750

-0.06250

-0.06250 0.00000 0.00000 0.00000

-0.06250

-0.06250 0.18750 547 145 1E12N055C

-0.50000

-0.31250

-0.37500

-0.43750

-0.37500

-0.43750

-0.43750

-0.18750

-0.43750 558 147 1E12N055C

-0.06250 0.00000 0.00000

-0.06250

-0.06250

-0.06250

-0.06250

-0.06250

-0.06250 548 149 1E12N055C 0.06250 0.00000 0.00000 0.06250 0.18750 0.06250 0.06250 0.06250 0.06250 504 151 lE12N055C 0.00000

-0.06250

-0.12500

-0.06250

-0.06250

-0.06250

-0.06250

-0.06250

-0.06250 574 153 1E12N055C

-0.06250

-0.12500

-0.18750

-0.12500

-0.12500

-0.18750

-0.37500

-0.12500 0.00000 559 155 1E12N055C 0.06250 0.18750 0.37500 0.25000 0.12500 0.31250 0.43750 0.25000 0.00000 588 159 1E12N056A 0.12500 0.12500 0.12500 0.12500 0.12500 0.12500 0.06250 0.12500 0.12500 539 161 1E12N056A

-0.31250

-0.31250

-0.31250

-0.31250

-0.31250

-0.31250

-0.31250

-0.31250

-0.25000 654 163 1E12N056A

-0.12500 0.06250 0.06250 0.12500 0.00000 0.06250 0.00000 0.00000

-0.12500 606 165 1E12N056A 0.06250 0.00000

-0.06250

-0.12500

-0.06250

-0.12500

-0.06250 0.06250 0.00000 530 167 1E12N056A

-0.06250

-0.12500 0.06250

-0.06250 0.06250 0.00000 0.12500

-0.06250

-0.06250 544 169 lE12N056A 0.06250

-0.37500

-0.50000

-0.62500

-0.56250

-0.68750

-0.68750

-0.43750

-0.06250 492 171 lE12N056A 0.03125 0.11250 0.06250 0.14375 0.18125 0.21875 0.18125 0.08750

-0.00625 542 173 1E12N056A

-0.11875

-0.03750 0.02500 0.01875

-0.05000 0.02500 0.03125

-0.06875

-0.01875 589 177 1E12N056B 0.18750 037500 0.31250 0.25000 0.18750 0.31250 0.37500 0.37500 0.12500 577 179 1E12N056B

-0.31250

-0.50000

-0.50000

-0.50000

-0.31250

-0.56250

-0.50000

-0.43750

-0.37500 544 181 1E12N056B

-0.06250 0.00000

-0.06250

-0.06250

-0.25000 0.00000

-0.06250

-0.06250 0.00000 546

DRIFT ANALYSIS ENGINEERING DEPARTMENT GRAND GULF NUCLEAR STATION Rosemount Range Codes 5 - 8 Gage Pressure Transmitters Outliers &Summary JC-Q1111-09019 Rev. 0 Page 102 of 134 Drift(Pt1)

Drift (Pt2)

Drift (Pt 3)

Drift (Pt 4)

Drift (Pt 5)

Drift (Pt 6)

Drift (Pt7)

Drift (Pt 8)

Drift (Pt9)

Cal Interval Seq.ID TaglD (0% Up)

(25"1. Up)

(50% Up)

(75% Up)

(100"1. Up)

(75"1. Dn)

(50%Dn)

(25%Dn)

(O%Dn)

(Days)

(%Span)

(%Span)

(%Span)

(%Span)

(%Span)

(%Span)

(%Span)

(%Span)

(%Span) 183 lE12N0568 0.06250 0.00000 0.12500 0.12500 0.12500 0.12500 0.12500 0.00000 0.06250 631 185 lE12N0568

-0.12500

-0.56250 0.00000

-0.75000

-0.87500

-0.81250

-0.68750

-0.50000

-0.12500 547 187 lE12N0568

-0.06250 0.12500 0.31250 0.68750 0.56250 0.62500 0.25000 0.37500 0.06250 503 189 lE12N0568 0.04375

-0.08125

-0.15000

-0.35000

-0.09375

-0.26250

-0.07500 0.03750

-0.05625 560 191 lE12N0568

-0.04375 0.20625 0.27500 0.22500

-0.09375 0.13750 0.32500 0.08750 0.05625 587 195 lE12N056C

-0.31250

-0.43750

-0.43750

-0.43750

-0.56250

-0.50000

-0.43750

-0.50000

-0.37500 637 197 lE12N056C

-0.06250 0.00000 0.00000 0.00000 0.12500 0.00000

-0.06250 0.00000 0.00000 545 199 lE12N056C 0.06250 0.06250 0.06250 0.18750 0.06250 0.18750 0.12500 0.06250 0.00000 560 201 lE12N056C 0.00000 0.00000

-0.12500

-0.18750

-0.25000

-0.18750

-0.18750

-0.12500 0.00000 616 203 lE12N056C 0.06250 0.12500 0.06250 0.06250 0.06250 0.06250 0.06250 0.00000 0.06250 476 205 lE12N056C

-0.12500

-0.18750

-0.06250

-0.12500

-0.12500

-0.12500

-0.12500

-0.06250

-0.12500 574 207 lE12N056C 0.22500

-0.08750

-0.50625

-0.15625

-0.25625

-0.38125

-0.41875

-0.11875 0.09375 560 209 lE12N056C

-0.22500

-0.03750 0.38125 0.09375 0.06875 0.25625 0.41875 0.18125

-0.09375 587 213 lE12N057 0.00000

-0.06250 0.00000

-0.06250

-0.06250

-0.12500

-0.06250

-0.06250

-0.06250 655 215 lE12N057

-0.06250 0.00000 0.06250 0.06250 0.06250 0.06250 0.12500 0.06250 0.00000 646 217 lE12N057 0.00000 0.00000

-0.06250

-0.06250

-0.06250

-0.06250

-0.18750

-0.06250 0.00000 545 219 lE12N057 0.00000 0.12500 0.12500 0.12500 0.06250 0.06250 0.12500 0.12500 0.06250 531 221 lE12N057 0.00000

-0.06250

-0.12500

-0.06250

-0.06250 0.06250

-0.12500

-0.06250

-0.06250 534 223 lE12N057 0.00000 0.00000 0.06250 0.00000 0.06250

-0.06250 0.12500 0.00000 0.00000 377 225 lE12N057

-0.12500

-0.18750

-0.12500

-0.25000

-0.25000

-0.18750

-0.31250

-0.18750

-0.18750 557 227 lE12N057

-0.15000

-0.08750

-0.20625

-0.16250

-0.13750

-0.12500

-0.08125

-0.05000 0.01250 551 231 lE12N058A

-0.06250

-0.12500

-0.12500

-0.06250

-0.06250 0.00000

-0.18750

-0.12500

-0.06250 670 233 lE12N058A 0.06250 0.00000 0.06250 0.00000 0.00000 0.00000 0.12500 0.00000 0.06250 603 235 lE12N058A 0.00000 0.00000

-0.06250 0.00000 0.00000 0.06250 0.00000 0.12500

-0.06250 543 237 lE12N058A

-0.06250 0.00000 0.00000 0.06250 0.00000 0.00000 0.00000

-0.06250 0.00000 560 239 lE12N058A 0.00000

-0.12500

-0.18750

-0.31250

-0.37500

-0.25000

-0.06250

-0.18750 0.00000 487 241 lE12N058A

-0.06250 0.12500 0.06250 0.06250 0.06250 0.00000 0.06250

-0.06250 594 243 lE12N058A 0.12500 0.00000 0.06250 0.00000 0.18750 0.06250 0.06250 0.06250 0.12500 489 245 lE12N058A

-0.31250

-0.06250

-0.06250

-0.18750

-0.25000

-0.12500

-0.12500

-0.12500

-0.31250 602 249 1E12N0588 0.00000

-0.12500

-0.18750

-0.12500

-0.06250

-0.12500

-0.18750

-0.25000 0.00000 589 251 lE12N0588

-0.12500 0.00000

-0.06250 0.00000 0.06250 0.00000 0.06250 0.12500 0.12500 547 253 lE12N0588 0.00000 0.12500 0.18750 0.12500 0.12500 0.12500 0.12500 0.06250 0.00000 560 255 lE12N0588 0.12500 0.00000

-0.06250

-0.06250

-0.06250

-0.12500

-0.18750

-0.12500 0.00000 532 257 lE12N0588 0.06250 0.06250 0.06250 0.00000 0.06250 0.18750 0.12500 0.12500 0.12500 545 259 lE12N0588

-0.18750

-0.06250 0.06250 0.12500

-0.18750

-0.06250 0.12500 0.00000

-0.12500 535 261 lE12N0588

-0.02500

-0.17500

-0.28750

-0.23125 0.02500

-0.11250

-0.21250

-0.10000 0.00000 529 263 lE12N0588 0.21250 0.17500 0.16250 0.10625 0.16250 0.05000 0.08750 0.10000 0.12500 591 267 lE12N058C

-0.25000

-0.18750

-0.18750

-0.12500

-0.25000

-0.12500

-0.12500

-0.25000

-0.18750 602 269 lE12N058C

-0.18750

-0.12500

-0.12500

-0.25000

-0.25000

-0.18750

-0.25000

-0.25000

-0.25000 570 271 lE12N058C 0.06250 0.00000 0.06250 0.12500 0.06250 0.00000 0.00000 0.06250 0.12500 562 273 1E12N058C 0.06250 0.06250 0.00000 0.06250 0.06250 0.00000 0.06250 0.00000 0.00000 574 275 lE12N058C 0.00000

-0.06250

-0.06250

-0.12500

-0.06250 0.06250 0.06250 0.12500 0.12500 462

DRIFT ANALYSIS ENGINEERING DEPARTMENT GRAND GULF NUCLEAR STATION Rosemount Range Codes 5 - 8 Gage Pressure Transmitters Outliers &Summary JC-Q1111-09019 Rev. 0 Page 103 of 134 Drift (Pt 1)

Drift (Pt 2)

Drift (Pt 3)

Drift (Pt 4)

Drift (Pt 5)

Drift (Pt 6)

Drift (Pt7)

Drift (Pt8)

Drift (Pt 9)

Cal Interval Seq. 10 Tag 10 (OOY.Up)

(25% Up)

(50% Up)

(75OY. Up)

(100% Up)

(75% On)

(50% On)

(25%Dn)

(0% On)

(Days)

(%Span)

(OY.Span)

(%Span)

(%Span)

(%Span)

(%Span)

(%Span)

(%Span)

(%Span) 277 1E12N058C

-0.12500

-0.12500

-0.06250

-0.18750

-0.37500

-0.25000

-0.31250

-0.25000

-0.12500 535 279 1E12N058C 0.00000

-0.18750

-0.25000

-0.12500

-0.06250

-0.12500

-0.12500

-0.06250 0.00000 515 281 1E12N058C 0.18750 0.50000 0.62500 0.62500 0.62500 0.50000 0.87500 0.43750 0.06250 558 285 1E21N050 0.00000 0.06250 0.00000 0.00000 0.06250 0.00000

-0.06250

-0.06250

-0.12500 645 287 1E21N050 0.06250 0.06250 0.06250 0.12500 0.00000 0.06250 0.00000 0.18750 0.12500 559 289 1E21N050

-0.06250

-0.06250

-0.12500

-0.18750

-0.12500

-0.12500 0.06250

-0.06250

-0.12500 662 291 1E21N050 0.00000

-0.06250 0.06250 0.06250 0.06250 0.00000

-0.06250 0.00000 0.06250 643 293 1E21N050

-0.06250

-0.06250 0.00000 0.00000

-0.18750 0.00000 0.06250 0.00000 0.00000 544 295 1E21N050

-0.12500

-0.25000

-0.18750

-0.12500

-0.18750

-0.06250

-0.18750

-0.12500

-0.25000 549 297 1E21N050 0.08125 0.15000 0.03125

-0.05625

-0.02500

-0.08125

-0.01875 0.01875 0.00000 554 299 1E21N050

-0.08125

-0.21250

-0.15625 0.05625 0.08750 0.01875

-0.04375

-0.08125 0.00000 589 303 1E21N052

-0.12500 0.00000 0.12500 0.06250 0.06250 0.12500 0.12500 0.00000

-0.12500 627 305 1E21N052

-0.37500

-0.50000

-0.37500

-0.50000

-0.50000

-0.50000

-0.43750

-0.50000

-0.37500 559 307 1E21N052 0.06250 0.06250

-0.12500

-0.12500

-0.06250

-0.12500

-0.06250

-0.06250 0.06250 577 309 1E21N052

-0.43750

-0.31250

-0.31250

-0.31250

-0.31250

-0.37500

-0.31250

-0.31250

-0.31250 657 311 1E21 N052 0.12500 0.68750 0.75000 1.37500 1.87500 1.37500 0.68750 0.62500 0.18750 532 313 1E21N052 0.12500 0.06250

-0.43750

-0.81250

-1.37500

-0.93750

-0.56250 0.00000 0.25000 486 315 1E21N052

-0.31250

-0.31250

-0.31250

-0.31250

-0.37500

-0.31250

-0.31250

-0.25000

-0.37500 550 317 1E21N052 0.05625

-0.20625

-0.23125

-0.21250

-0.10625

-0.11875

-0.18750

-0.24375 0.05000 562 321 1E21N053

-0.12500 0.00000

-0.06250

-0.06250

-0.06250 0.00000

-0.06250

-0.06250

-0.06250 543 323 1E21N053 0.12500

-0.06250 0.00000

-0.12500 0.06250

-0.12500 0.06250 0.00000 0.12500 548 325 1E21N053 0.06250 0.12500 0.00000 0.18750

-0.18750 0.18750 0.00000 0.06250 0.06250 570 327 1E21N053

-0.12500

-0.12500 0.00000

-0.12500 0.12500

-0.12500

-0.06250

-0.06250

-0.12500 550 329 1E21N053 0.00000 0.06250 0.37500 0.87500 1.25000 0.87500 0.37500 0.00000 0.00000 558 331 1E21N053

-0.31250 0.12500 0.25000 0.12500 0.25000 0.18750 0.25000 0.18750

-0.25000 487 333 1E21N053

-0.41875

-0.62500

-0.62500

-0.81250

-0.87500

-0.75000

-0.75000

-0.62500

-0.36875 549 335 1E21N053 0.08125

-0.11250

-0.08750 0.05000 0.01250 0.16250 0.00000 0.00625 0.00625 563 339 1E21N054

-0.12500 0.06250 0.06250

-0.06250

-0.25000

-0.25000 0.00000 0.12500

-0.06250 673 341 1E21N054 1.00000 0.50000 0.37500 0.37500 0.00000 0.25000 0.37500 0.50000 1.00000 563 343 1E21N054 0.00000 0.00000 0.00000 0.00000

-0.06250 0.00000 0.00000 0.00000

-0.06250 644 345 1E21N054 0.00000 0.12500

-0.06250

-0.18750

-0.06250 0.06250 0.06250 0.12500 0.00000 601 347 1E21N054

-0.06250

-0.18750

-0.06250 0.06250

-0.12500

-0.06250 0.06250 0.00000 0.00000 516 349 1E21N054 0.06250 0.06250 0.06250 0.06250 0.12500 0.06250

-0.06250

-0.06250 0.06250 534 351 1E21N054

-0.08750

-0.06250

-0.04375 0.05000 0.04375

-0.06250

-0.08750

-0.06875

-0.09375 561 353 1E21N054 0.08750 0.00000 0.10625

-0.11250

-0.16875

-0.12500 0.02500 0.00625 0.09375 543 357 1E22N050

-0.12500

-0.18750

-0.25000

-0.25000

-0.25000

-0.25000

-0.18750 630 359 1E22N050

-0.12500

-0.12500

-0.06250

-0.06250

-0.06250

-0.06250

-0.12500 590 361 1E22N050

-0.06250

-0.06250

-0.12500

-0.31250

-0.18750

-0.12500

-0.18750 530 363 1E22N050

-1.56250

-0.43750

-1.00000

-0.68750

-0.93750

-1.50000

-1.12500 616 365 1E22N050

-0.81250

-0.62500

-0.50000

-0.62500

-0.56250

-0.62500

-0.75000 532 367 1E22N050

-0.43750

-0.31250

-0.25000

-0.12500

-0.18750 0.06250

-0.31250 504 369 1E22N050 0.62500 0.37500 0.25000 0.25000 0.12500 0.06250 0.18750 602

DRIFT ANALYSIS ENGINEERING DEPARTMENT GRAND GULF NUCLEAR STATION Rosemount Range Codes 5 - 8 Gage Pressure Transmitters Outliers &Summary JC-Q1111-09019 Rev. 0 Page 104 of 134 Drift(Pt1)

Drift (Pt2)

Drift (Pt 3)

Drift (Pt4)

Drift(Pt5)

Drift (Pt6)

Drift (Pt 7)

Drift(Pt8)

Drift (Pt 9)

Cal Interval Seq. 10 Tag 10 (0% Up)

(25% Up)

(500/. Up)

(75% Up)

(100% Up)

(75% On)

(50% On)

(25% On)

(0% On)

(Days)

(%Span)

(%Span)

(%Span)

(%Span)

(%Span)

(%Span)

(%Span)

(%Span)

(%Span) 371 1E22N05O 0.15000

-0.18750

-0.15625

-0.32500 0.08750

-0.01250

-0.15000 574 375 lE22N054C 0.06250 0.12500 0.18750 0.12500 0.12500 0.12500 0.12500 0.12500 0.06250 672 377 lE22N054C 0.12500 0.18750 0.12500 0.12500 0.18750 0.12500 0.12500 0.12500 0.12500 504 381 1E22N054G 0.06250 0.06250 0.00000 0.06250 0.12500 0.18750 0.12500 0.12500 0.12500 539 383 1E22N054G 0.00000 0.00000 0.00000 0.00000

-0.06250 0.00000 0.00000 0.06250 0.00000 588 387 1E31N085A 0.12500 0.06250 0.00000 0.00000 0.00000 0.06250 0.00000 0.00000 0.12500 589 389 1E31N085A

-0.12500

-0.18750

-0.18750

-0.12500

-0.18750

-0.18750

-0.25000

-0.18750

-0.25000 547 391 1E31N085A

-0.12500 0.06250

-0.06250 0.00000 0.00000 0.00000 0.00000 0.06250 0.00000 551 393 1E31N085A 0.06250

-0.12500

-0.25000

-0.25000

-0.50000

-0.25000

-0.18750 0.00000 0.12500 572 395 1E31N085A

-0.12500

-0.06250 0.00000

-0.12500

-0.12500

-0.12500

-0.06250

-0.06250

-0.37500 529 397 1E31N085A

-0.12500

-0.12500

-0.18750

-0.12500 0.12500

-0.12500

-0.18750

-0.12500 0.12500 517 399 1E31N085A 0.75000 1.00000 1.00000 1.12500 0.93750 1.18750 1.06250 1.00000 0.75000 537 401 1E31N085A

-1.37500

-1.56250

-1.56250

-1.70000

-1.75000

-1.63125

-1.64375

-1.48750

-1.19375 559 405 1E31N085B

-0.31250

-0.43750

-0.56250

-0.62500

-0.50000

-0.56250

-0.62500

-0.56250

-0.37500 581 407 1E31N085B

-0.12500

-0.12500

-0.06250 0.00000

-0.06250 0.00000 0.00000 0.06250

-0.06250 548 409 1E31N085B 0.25000 0.56250 0.62500 0.62500 0.56250 0.43750 0.43750 0.50000 0.25000 551 411 1E31N085B

-0.06250

-0.37500

-0.25000

-0.37500

-0.50000

-0.31250

-0.25000

-0.18750 0.06250 572 413 1E31 N085B 9.31250 11.37500 11.12500 10.56250 9.75000 11.06250 11.06250 11.00000 12.43750 528 415 lE31N085B

-0.18750 0.12500 0.43750 0.68750 1.25000 1.18750 0.62500 0.18750

-0.12500 522 417 lE31N085B 0.62500 0.37500 0.00000

-0.37500

-0.68750

-0.37500 0.00000 0.37500 0.62500 519 419 lE31N085B

-0.68125

-0.66875

-1.06875

-1.00625

-1.07500

-0.93750

-0.90625

-0.75625

-0.48125 572 423 lE32N05O 0.00000 0.00000

-0.06250

-0.06250 0.00000 0.00000 0.00000 0.00000 0.00000 577 425 lE32N05O

-0.06250 0.12500 0.12500 0.12500 0.18750 0.12500 0.18750 0.12500

-0.06250 549 427 lE32N05O 0.37500 0.06250 0.12500 0.06250 0.12500 0.18750 0.18750 0.25000 0.25000 552 429 lE32N05O

-0.37500

-0.12500

-0.18750

-0.06250

-0.18750

-0.18750

-0.31250

-0.37500

-0.25000 571 433 lE32N05O 0.00000 0.12500 0.06250 0.06250 0.06250 0.06250 0.06250 0.25000 0.12500 513 435 lE32N05O

-2.37500

-2.25000

-2.25000

-2.25000

-2.12500

-2.18750

-2.06250

-2.18750

-2.50000 544 437 lE32N05O 1.37500 0.93750 0.18750

-0.68750

-1.56250

-0.75000 0.18750 0.81250 1.43750 159 439 lE32N05O 0.06875 1.05625 1.56250 2.68750 3.54375 2.68750 1.43750 0.99375

-0.11875 602 443 lE32N055 0.06250

-0.06250

-0.06250

-0.06250

-0.12500

-0.06250 0.00000

-0.06250 0.00000 548 445 1E32N055

-0.06250 0.12500 0.12500 0.25000 0.25000 0.18750 0.18750 0.12500 0.00000 642 447 lE32N055 0.00000 0.00000 0.12500 0.00000 0.00000 0.00000 0.00000 0.06250 0.06250 546 449 lE32N055

-0.12500

-0.18750

-0.25000

-0.18750

-0.18750

-0.25000

-0.12500

-0.18750

-0.06250 533 451 1E32N055 0.25000 0.18750 0.06250 0.18750 0.25000 0.25000 0.06250 0.12500 0.25000 519 453 1E32N055 0.31250

-0.06250 0.06250

-0.18750

-0.37500

-0.25000

-0.12500

-0.12500 0.18750 459 455 lE32N055 0.00000

-0.18750

-0.37500

-0.37500

-0.18750

-0.18750

-0.25000

-0.18750 0.06250 548 457 lE32N055 0.12500

-0.06250 0.06250 0.06250 0.00000

-0.06250 0.12500

-0.06250

-0.12500 546 461 1E32N058

-0.06250

-0.06250

-0.12500

-0.18750

-0.25000

-0.18750

-0.12500

-0.06250

-0.06250 575 463 1E32N058 0.06250 0.00000 0.00000 0.00000 0.00000 0.00000 0.06250 0.00000 0.06250 557 465 1E32N058

-0.06250 0.06250 0.12500 0.18750 0.25000 0.18750 0.06250 0.06250

-0.06250 549 467 1E32N058 0.00000 0.00000 0.00000 0.00000 0.06250 0.00000 0.00000

-0.06250 0.00000 566 471 1E32N058

-0.62500

-0.50000

-0.43750

-0.62500

-0.56250

-0.62500

-0.56250

-0.50000

-0.62500 510

DRIFT ANALYSIS ENGINEERING DEPARTMENT GRAND GULF NUCLEAR STATION Rosemount Range Codes 5 - 8 Gage Pressure Transmitters Outliers & Summary JC-Q1111-09019 Rev. 0 Page 105 of 134 Drift (Pt 1)

Drift (Pt 2)

Drift (Pt 3)

Drift (Pt 4)

Drift (Pt5)

Drift (Pt 6)

Drift (Pt7)

Drift (Pt8)

Drift (Pt9)

Cal Interval Seq. 10 Tag 10 (0% Up)

(25% Up)

(50% Up)

(75% Up)

(100% Up)

(75% On)

(50"1. On)

(25% On)

(0% On)

(Days)

(%Span)

("I.Span)

("I.Span)

("I.Span)

(%Span)

(%Span)

(%Span)

(%Span)

(%Span) 477 1E32N058 0.87500 1.87500 2.75000 3.56250 4.43750 3.56250 2.62500 2.00000 0.93750 601 481 1E32N061A 0.06250 0.06250 0.00000 0.00000 0.00000 0.06250 0.00000 0.06250 0.06250 544 483 1E32N061A

-0.06250

-0.06250 0.00000 0.00000 0.00000

-0.06250 0.00000

-0.06250

-0.06250 536 485 1E32N061A 0.06250 0.06250 0.00000 0.00000 0.00000 0.00000 0.00000 0.06250 0.06250 598 489 1E32N061A

-0.31250

-0.31250

-0.43750

-0.37500

-0.31250

-0.31250

-0.43750

-0.37500

-0.31250 533 491 1E32N061A

-0.06250 0.06250 0.37500 0.50000 0.50000 0.37500 0.37500 0.00000

-0.06250 420 493 1E32N061A

-0.25000

-0.18750

-0.31250

-0.62500

-0.68750

-0.62500

-0.43750

-0.18750

-0.18750 542 495 1E32N061A 0.31250 0.00000 0.00000 0.00000 0.06250 0.06250 0.12500 0.12500 0.18750 548 499 1E32N061E

-0.06250

-0.06250 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000

-0.06250 642 501 1E32N061E

-0.06250

-0.06250

-0.06250 0.00000

-0.06250 0.00000 0.00000

-0.06250

-0.06250 656 503 1E32N061E 0.06250 0.12500 0.12500 0.12500 0.25000 0.12500 0.12500 0.12500 0.06250 533 507 1E32N061E

-0.43750

-0.50000

-0.56250

-0.56250

-0.50000

-0.50000

-0.50000

-0.50000

-0.43750 546 509 1E32N061E

-0.31250

-0.31250

-0.43750

-0.50000

-0.50000

-0.50000

-0.43750

-0.31250

-0.31250 363 511 1E32N061E 0.12500 0.31250 0.43750 0.50000 0.37500 0.37500 0.50000 0.25000 0.25000 601 513 1E32N061E

-0.31250

-0.18750

-0.37500

-0.43750

-0.25000

-0.25000

-0.37500

-0.37500

-0.25000 548 517 1E32N061J

-0.25000

-0.25000

-0.25000

-0.18750

-0.18750

-0.18750

-0.12500

-0.18750

-0.12500 543 519 1E32N061J 0.06250 0.12500 0.18750 0.12500 0.06250 0.06250 0.06250 0.06250 0.00000 547 521 1E32N061J

-0.06250

-0.12500

-0.06250

-0.12500

-0.18750

-0.18750

-0.18750

-0.06250

-0.06250 589 525 1E32N061J

-0.12500 0.00000 0.00000 0.00000 0.06250 0.06250 0.00000 0.00000

-0.12500 507 527 1E32N061J

-0.12500

-0.18750

-0.25000

-0.12500 0.12500

-0.12500

-0.12500

-0.18750

-0.31250 476 529 1E32N061J 0.62500 0.50000 0.56250 0.56250 0.56250 0.50000 0.56250 0.62500 0.75000 544 531 1E32N061J 0.06250 0.00000 0.06250 0.12500 0.18750 0.18750 0.18750 0.12500 0.06250 560 535 1E32N061N 0.00000

-0.06250 0.00000 0.06250

-0.06250 0.00000 0.00000 0.00000 0.00000 540 537 1E32N061N 0.00000 0.00000 0.00000

-0.06250 0.00000 0.00000

-0.06250 0.00000 0.00000 658 539 1E32N061N 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.06250 0.00000 598 543 1E32N061N

-0.50000

-0.50000

-0.50000

-0.37500

-0.25000

-0.31250

-0.43750

-0.43750

-0.50000 550 545 1E32N061N

-0.18750

-0.25000

-0.12500

-0.06250 0.00000

-0.06250

-0.12500

-0.12500

-0.31250 406 547 1E32N061N 0.41250 0.36250

-0.08125

-0.29375

-0.26875

-0.25000 0.00625 0.23750 0.36250 541 549 1E32N061N

-0.10000

-0.30000

-0.16875 0.10625 0.08125 0.06250

-0.13125

-0.05000 0.13750 550 553 1E51N035A 0.00000

-0.06250

-0.06250

-0.06250

-0.06250 0.06250 0.06250 0.00000

-0.06250 661 555 1E51N035A

-0.06250 0.00000

-0.06250

-0.06250 0.06250 0.00000

-0.12500 0.00000 0.00000 152 557 1E51N035A

-0.06250

-0.06250 0.00000 0.00000

-0.12500 0.00000 0.06250 0.00000 0.06250 545 561 1E51N035E 0.18750 0.06250 0.00000 0.00000 0.00000 0.06250 0.00000 0.12500 0.18750 664

DRIFT ANALYSIS ENGINEERING DEPARTMENT GRAND GULF NUCLEAR STATION Rosemount Range Codes 5 - 8 Gage Pressure Transmitters Outliers &Summary JC-Q1111-09019 Rev. 0 Page 106 of 134 Orift(Pt1)

Drift (P12)

Orift(Pt3)

Drift (Pt4)

Orift(Pt5)

Drift (P16)

Drift (Pt7)

Drift (Pt 8)

Drift (P19)

Cal Interval Seq. 10 Tag 10 (0% Up)

(25% Up)

(50% Up)

(75% Up)

(100% Up)

(75% On)

(50% On)

(25% On)

(0% On)

(Days)

(%Span)

(%Span)

(%Span)

(%Span)

(%Span)

(%Span)

(%Span)

("I.Span)

(%Span) 563 1E51N035E 0.06250 0.06250 0.06250 0.12500 0.06250 0.06250 0.12500 0.00000

-0.06250 631 567 1E51N055A 0.06250 0.00000 0.00000

-0.06250

-0.12500 0.00000 0.00000 0.00000 0.06250 544 569 1E51N055A 0.00000 0.00000

-0.06250

-0.12500

-0.06250

-0.12500

-0.12500

-0.06250 0.00000 655 571 1E51 N055A

-0.06250 0.00000 0.06250 0.12500 0.12500 0.12500 0.12500 0.06250 0.00000 591 573 1E51N055A 0.06250 0.00000 0.00000 0.00000 0.06250 0.00000 0.00000 0.00000 0.00000 532 575 1E51N055A 0.00000

-0.06250

-0.06250

-0.12500

-0.12500

-0.12500

-0.06250

-0.06250 0.00000 666 577 1E51N055A

-0.12500

-0.18750

-0.12500

-0.12500 0.00000

-0.06250

-0.12500

-0.12500

-0.12500 543 579 1E51 N055A 0.06250 0.12500 0.00000 0.00000

-0.12500

-0.06250 0.00000 0.06250 0.06250 557 583 1E51N0558

-0.06250

-0.06250

-006250

-0.12500

-0.12500

-0.12500

-0.06250

-0.06250

-0.06250 651 585 1E51N0558 0.06250 0.06250 0.06250 0.06250 0.00000 0.06250 0.06250 0.06250 0.06250 531 587 1E51N0558 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 547 589 1E51N0558 0.00000 0.00000 0.00000

-0.06250

-0.12500

-0.06250 0.00000 0.00000

-0.06250 646 591 1E51N0558 0.00000

-0.06250

-0.06250 0.00000 0.00000

-0.06250

-0.06250

-0.06250 0.00000 531 593 1E51N0558 0.00000 0.00000 0.12500 0.00000 0.06250 0.06250 0.12500 0.06250 0.00000 579 595 1E51 N0558 0.00000 0.06250

-0.12500

-0.06250

-0.06250

-0.06250

-0.06250 0.00000 0.06250 521 597 1E51N0558

-0.06250 0.00000 0.00000 0.00000 0.00000 0.00000

-0.06250

-0.06250 0.00000 575 601 1E51N055E

-0.06250

-0.06250

-0.06250

-0.06250

-0.06250

-0.06250

-0.06250 0.06250

-0.06250 603 603 1E51N055E 0.00000 0.00000

-0.06250 0.00000 0.12500 0.00000 0.06250 0.00000 0.00000 632 605 1E51N055E 0.06250 0.00000 0.06250 0.00000

-0.06250 0.06250 0.06250 0.06250 0.06250 658 607 1E51N055E 0.06250 0.06250 0.06250 0.06250 0.12500 0.00000

-0.06250 0.00000 0.06250 671 609 1E51N055E

-0.12500

-0.18750

-0.25000

-0.18750

-0.31250

-0.18750

-0.18750

-0.18750

-0.12500 665 611 1E51N055E 0.00000 0.06250 0.12500

-0.06250 0.18750 0.06250 0.12500 0.12500 0.06250 544 613 1E51N055E 0.12500 0.06250 0.06250 0.12500

-0.06250 0.00000

-0.06250 0.00000 0.06250 557

DRIFT ANALYSIS ENGINEERING DEPARTMENT GRAND GULF NUCLEAR STATION Rosemount Range Codes 5 - 8 Gage Pressure Transmitters Outliers &Summary JC-Q1111-09019 Rev. 0 Page 107 of 134 Drift(Pt1)

Drift (Pt2)

Drift (Pt 3)

Drift (Pt4)

Drift(Pt5)

Drift (Pt 6)

Drift (Pt 7)

Drift (Pt 8)

Drift (Pt 9)

Cal Interval Seq. 10 Tag 10 (0% Up)

(25% Up)

(50% Up)

(75% Up)

(100% Up)

(75% On)

(50% On)

(25% On)

(0% On)

(Days)

(%Span)

("I.Span)

(%Span)

(%Span)

(%Span)

(%Span)

(%Span)

(%Span)

(%Span) 617 1E51N055F 0.00000

-0.06250

-0.12500

-0.06250

-0.06250

-0.06250

-0.06250 0.00000 0.00000 628 619 1E51N055F 0.00000 0.06250 0.12500 0.06250 0.06250 0.06250 0.12500 0.06250 0.06250 604 621 1E51N055F 0.12500 0.06250 0.00000 0.06250 0.06250 0.06250 0.00000 0.00000 0.06250 628 623 1E51N055F

-0.12500

-0.06250 0.00000

-0.06250 0.00000

-0.06250 0.00000 0.00000

-0.06250 532 625 1E51N055F 0.12500 0.00000 0.00000 0.00000

-0.12500 0.06250 0.06250 0.06250 0.00000 580 627 1E51N055F

-0.06250 0.06250 0.06250 0.00000 0.06250

-0.06250 0.00000 0.00000 0.06250 521 629 1E51N055F 0.00000 0.12500 0.18750 0.25000 0.25000 0.25000 0.18750 0.12500 0.00000 575 Initial Drift Data Statistics Summary. Prior to Outlier Removal Data Pt.

1 2

3 4

5 6

7 B

9 Mean 0.0109 0.0128 0.0148 0.0103 0.0113 0.0188 0.0114 0.0189 0.0273 Variance 0.4030 0.5711 0.5725 0.5899 0.6040 0.6294 0.5742 0.5406 0.6633 Median 0.00000 0.00000 0.00000 0.00000

-0.02500 0.00000 0.00000 0.00000 0.00000 Std. Dev.

0.6348 0.7597 0.7567 0.7681 0.7712 0.7934 0.7578 0.7353 0.8144 Count 262 270 270 270 269 270 270 270 262 Maximum 9.31250 11.37500 11.12500 10.56250 9.75000 11.06250 11.06250 11.00000 12.43750 Minimum

-2.37500

-2.25000

-2.25000

-2.25000

-2.12500

-2.18750

-2.06250

-2.18750

-2.50000 Range 11.68750 13.62500 13.37500 12.81250 11.87500 13.25000 13.12500 13.18750 14.93750 Sum 2.85625 3.44375 3.98750 2.78125 3.04375 5.08750 3.07500 5.11250 7.16250 Kurtosis 178.684 187.851 174.812 135.201 97.359 142.107 169.914 186.756 208.782 Skewness 11.953 12.432 11.918 10.101 8.329 10.466 11.639 12.406 13.559 Mean+2*StD 1.2806 1.5321 1.5281 1.5464 1.5657 1.6056 1.5270 1.4894 1.6562 Critical T 4.00 4.00 4.00 4.00 4.00 4.00 4.00 4.00 4.00 Crit T Value Lookup (5% Significance), per Sample Size.

(Per Section 3.6.2 ofReference 4.1.3)

DRIFT ANALYSIS ENGINEERING DEPARTMENT GRAND GULF NUCLEAR STATION Rosemount Range Codes 5 - 8 Gage Pressure Transmitters Outliers &Summary Ext. Stud.

Ext. Stud.

Ext. Stud.

Ext. Stud.

Ext. Stud.

Ext. Stud.

Ext. Stud.

Ext. Stud.

Ext. Stud.

Deviate Deviate Deviate Deviate Deviate Deviate Deviate Deviate Deviate Point 1 Point 2 Point 3 Point 4 Point 5 Point 6 Point 7 Point 8 Point 9 (0% Up)

(25% Up)

(50% Up)

(75% Up)

(100% Up)

(75%Dn)

(5O%Dn)

(25% Dn)

(O%Dn) 0.017 0.017 0.020 0.068 0.066 0.055 0.067 0.026 0.034 0.081 0.065 0.020 0.095 0.175 0.103 0.015 0.059 0.043 0.017 0.230 0.393 0.719 1.513 0.843 0.397 0.314 0.110 0.017 0.065 0.146 0.231 0.227 0.134 0.067 0.059 0.043 0.116 0.230 0.146 0.068 0.066 0.134 0.232 0.314 0.187 0.692 0.065 0.276 0.192 0.031 0.095 0.122 0.085 0.496 0.135 0.099 0.154 0.084 0.079 0.126 0.092 0.136 0.103 0.081 0.065 0.020 0.013 0.015 0.024 0.015 0.059 0.043 0.017 0.065 0.053 0.068 0.015 0.024 0.015 0.059 0.034 0.017 0.017 0.020 0.176 0.066 0.103 0.015 0.111 0.034 0.017 0.099 0.069 0.013 0.175 0.024 0.098 0.111 0.034 0.017 0.230 0.063 0.312 0.307 0.291 0.232 0.314 0.120 0.081 0.181 0.020 0.258 0.256 0.260 0.180 0.196 0.110 0.017 0.017 0.063 0.149 0.015 0.024 0.180 0.111 0.110 0.081 0.065 0.185 0.258 0.095 0.024 0.067 0.144 0.043 0.081 0.017 0.102 0.013 0.175 0.103 0.098 0.026 0.043 0.180 0.148 0.146 0.068 0.066 0.055 0.067 0.229 0.120 0.081 0.065 0.146 0.149 0.146 0.213 0.150 0.059 0.043 0.411 0.264 0.267 0.176 0.095 0.181 0.262 0.366 0.341 0.017 0.099 0.102 0.095 0.095 0.103 0.015 0.026 0.034 0.180 0.148 0.020 0.149 0.146 0.134 0.067 0.144 0.043 0.313 0.099 0.063 0.095 0.095 0.024 0.067 0.026 0.187 0.017 0.017 0063 0.068 0.066 0.024 0.067 0.059 0.110 0.214 0.099 0.267 0.176 0.175 0.181 0.098 0.111 0.110 0.017 0.017 0.146 0.068 0.066 0.055 0.015 0.111 0.034 0.017 0.017 0.102 0.095 0.095 0.103 0.098 0.026 0.043 0.116 0.264 0.267 0.258 0.256 0.260 0.262 0.196 0.110 0.116 0.065 0.102 0.013 0.095 0.055 0.015 0.059 0.110 0.081 0.017 0.020 0.095 0.146 0.024 0.067 0.059 0.043 0.204 0.099 0.020 0.160 0.211 0.032 0.040 0.153 0.103 0.214 0.099 0.102 0.095 0.095 0.260 0.098 0.111 0.417 0.411 0.065 0.063 0.068 0.146 0.134 0.067 0.059 0.034 0.017 0.017 0.102 0.176 0.175 0.260 0.180 0.111 0.034 0.017 0.017 0.063 0.013 0.015 0.024 0.015 0.111 0.034 0.214 0.181 0.185 0.095 0.095 0.103 0.180 0.111 0.264 0.017 0.065 0.185 0.176 0.015 0.103 0.067 0.059 0.043 0.180 0.181 0.063 0.013 0.095 0.103 0.180 0.196 0.197 0.175 0.066 0.276 0.119 0.401 0.173 0.139 0.085 0.271 JC-Q1111-09019 Rev. 0 Page 108 of 134

DRIFT ANALYSIS ENGINEERING DEPARTMENT GRAND GULF NUCLEAR STATION Rosemount Range Codes 5 - 8 Gage Pressure Transmitters Outliers &Summary Ext. Stud.

Ext. Stud.

Ext. Stud.

Ext. Stud.

Ext. Stud.

Ext. Stud.

Ext. Stud.

Ext. Stud.

Ext. Stud.

Deviate Deviate Deviate Deviate Deviate Deviate Deviate Deviate Deviate Point 1 Point 2 Point 3 Point 4 Point 5 Point 6 Point 7 PointS Point 9 (0% Up)

(25"1. Up)

(50% Up)

(75% Up)

(100% Up)

(75%Dn)

(5O%Dn)

(25% Dn)

(O%Dn) 0.116 0.099 0.185 0.095 0.095 0.103 0.180 0.111 0.034 0.081 0.148 0.228 0.149 0.146 0.055 0.150 0.059 0.034 0.313 0.181 0.102 0.095 0.095 0.024 0.098 0.111 0.187 0.081 0.017 0.102 0.095 0.015 0.103 0.015 0.026 0.043 0.017 0.099 0.102 0.095 0.095 0.103 0.098 0.111 0.034 0.017 0.065 0.063 0.231 0.015 0.055 0.150 0.144 0.034 0.017 0.099 0.102 0.258 0.015 0.103 0.180 0.281 0.034 0.145 0.190 0.003 0.192 0.175 0.181 0.180 0.051 0.172 0.180 0.230 0.228 0.231 0.066 0.213 0.150 0.229 0.120 0.116 0.099 0.102 0.176 0.095 0.181 0.098 0.196 0.110 0.017 0.065 0.020 0.149 0.066 0.134 0.067 0.059 0.034 0.116 0.181 0.185 0.339 0.175 0.260 0.262 0.196 0.043 0.116 0.099 0.185 0.095 0.175 0.103 0.098 0.196 0.187 0.116 0.148 0.020 0.149 0.227 0.103 0.180 0.144 0.187 0.145 0.024 0.228 0.369 0.339 0.331 0.290 0.527 0.103 0.071 0.017 0.047 0.027 0.114 0.008 0.081 0.340 0.018 0.017 0.148 0.146 0.068 0.095 0.055 0.150 0.144 0.034 0.116 0.099 0.102 0.176 0.095 0.181 0.098 0.111 0.110 0.214 0.346 0.267 0.339 0.336 0.339 0.345 0.366 0.187 0.116 0.099 0.102 0.095 0.175 0.103 0.015 0.026 0.110 0.081 0.264 0.350 0.420 0.336 0.339 0.262 0.281 0.034 0.017 0.099 0.063 0.176 0.417 0.024 0.150 0.059 0.034 0.017 0.099 0.317 0.152 0.154 0.378 0.320 0.357 0.041 0.180 0.065 0.195 0.206 0.264 0.331 0.125 0.306 0.051 0.017 0.148 0.146 0.149 0.146 0.134 0.150 0.229 0.034 0.278 0.099 0.102 0.013 0.Q15 0.024 0.098 0.111 0.197 0.805 0.428 0.515 0.583 0.497 0.575 0.592 0.281 0.571 0.116 0.017 0.020 0.095 0.095 0.103 0.098 0.111 0.110 0.081 0.017 0.020 0.068 0.227 0.055 0.067 0.059 0.043 0.017 0.099 0.185 0.095 0.095 0.103 0.098 0.111 0.110 0.116 0.181 0.267 0.176 0.175 0.260 0.510 0.196 0.034 0.081 0.230 0.476 0.312 0.146 0.370 0.562 0.314 0.034 0.180 0.148 0.146 0.149 0.146 0.134 0.067 0.144 0.120 0.509 0.428 0.433 0.420 0.417 0.418 0.427 0.451 0.341 0.214 0065 0.063 0.149 0.015 0.055 0.015 0.026 0.187 0.081 0.017 0.102 0.176 0.095 0.181 0.098 0.059 0.034 0.116 0.181 0.063 0.095 0.066 0.024 0.150 0.111 0.110 0.081 0.510 0.680 0.827 0.738 0.890 0.922 0.621 0.110 0.032 0.131 0.063 0.174 0.219 0.252 0.224 0.093 0.041 0.204 0.066 0.014 0.011 0.079 0.008 0.026 0.119 0.057 0.278 0.477 0.393 0.312 0.227 0.370 0.480 0.484 0.120 0.509 0.675 0.680 0.664 0.417 0.733 0.675 0.621 0.494 0.116 0.017 0.102 0.095 0.336 0.024 0.098 0.111 0.034 JC-Q1111-09019 Rev. 0 Page 109 of 134

DRIFT ANALYSIS ENGINEERING DEPARTMENT GRAND GULF NUCLEAR STATION Rosemount Range Codes 5 - 8 Gage Pressure Transmitters Outliers &Summary Ext. Stud.

Ext. Stud.

Ext. Stud.

Ext. Stud.

Ext. Stud.

Ext. Stud.

Ext. Stud.

Ext. Stud.

Ext. Stud.

Deviate Deviate Deviate Deviate Deviate Deviate Deviate Deviate Deviate Point 1 Point 2 Point 3 Point 4 Point 5 Point 6 Point 7 PointS Point 9 (0% Up)

(25"1aUp)

(5O"laUp)

(75% Up)

(100% Up)

(75'Y. Dn)

(50% Dn)

(25% Dn)

(0% Dn) 0.081 0.017 0.146 0.149 0.146 0.134 0.150 0.026 0.043 0.214 0.757 0.020 0.990 1.140 1.048 0.922 0.706 0.187 0.116 0.148 0.393 0.882 0.709 0.764 0.315 0.484 0.043 0.052 0.124 0.218 0.469 0.135 0.355 0.114 0.025 0.103 0.086 0.255 0.344 0.280 0.135 0.150 0.414 0.093 0.036 0.509 0.593 0.598 0.583 0.738 0.654 0.592 0.706 0.494 0.116 0.017 0.020 0.013 0.146 0.024 0.098 0.026 0.034 0.081 0.065 0.063 0.231 0.066 0.213 0.150 0.059 0.034 0.017 0017 0.185 0.258 0.336 0.260 0.262 0.196 0.034 0.081 0.148 0.063 0.068 0.066 0055 0.067 0.026 0.043 0.214 0.264 0.102 0.176 0.175 0.181 0.180 0.111 0.187 0.337 0.132 0.689 0.217 0.344 0.504 0.568 0.187 0.082 0.372 0.066 0.484 0.109 0.074 0.299 0.538 0.221 0.149 0.017 0.099 0.020 0.095 0.095 0.181 0.098 0.111 0.110 0.116 0.017 0.063 0.068 0.066 0.055 0.150 0.059 0.034 0.017 0.017 0.102 0.095 0.095 0.103 0.262 0.111 0.034 0.017 0.148 0.146 0.149 0.066 0.055 0.150 0.144 0.043 0.017 0.099 0.185 0.095 0.095 0.055 0.180 0.111 0.110 0.017 0.017 0.063 0.013 0.066 0.103 0.150 0.026 0.034 0.214 0.264 0.185 0.339 0.336 0.260 0.427 0.281 0.264 0.253 0.132 0.292 0.225 0.191 0.181 0.122 0.094 0.018 0.116 0.181 0.185 0.095 0.095 0.024 0.262 0.196 0.110 0.081 0.017 0.063 0.013 0.015 0.024 0.150 0.026 0.043 0.017 0.017 0.102 0.013 0.Q15 0.055 0.015 0.144 0.110 0.116 0.017 0.020 0.068 0.015 0.024 0.015 0.111 0.034 0.017 0.181 0.267 0.420 0.497 0.339 0.098 0.281 0.034 0.116 0.148 0.063 0.068 0.055 0.015 0.059 0.110 0.180 0.017 0.063 0.013 0.227 0.055 0.067 0.059 0.120 0.509 0.099 0.102 0.258 0.336 0.181 0.180 0.196 0.417 0.017 0.181 0.267 0.176 0.095 0.181 0.262 0.366 0.034 0.214 0.017 0.102 0.013 0.066 0.024 0.067 0.144 0.120 0.017 0.148 0.228 0.149 0.146 0.134 0.150 0.059 0.034 0.180 0.017 0.102 0.095 0.095 0.181 0.262 0.196 0.034 0.081 0.065 0.063 0.013 0.066 0.213 0.150 0.144 0.120 0.313 0.099 0.063 0.149 0.256 0.103 0.150 0.026 0.187 0.057 0.247 0.399 0.314 0.018 0.166 0.295 0.162 0.034 0.318 0.214 0.195 0.125 0.195 0.039 0.100 0.110 0.120 0.411 0.264 0.267 0.176 0.336 0.181 0.180 0.366 0.264 0.313 0.181 0.185 0.339 0.336 0.260 0.345 0.366 0.341 0.081 0.017 0.063 0.149 0.066 0.024 0.015 0.059 0.120 0.081 0.065 0.020 0.068 0.066 0.024 0.067 0.026 0.034 0.017 0.099 0.102 0.176 0.095 0.055 0.067 0.144 0.120 JC-Q1111-09019 Rev. 0 Page 110 of 134

DRIFT ANALYSIS ENGINEERING DEPARTMENT GRAND GULF NUCLEAR STATION Rosemount Range Codes 5 - 8 Gage Pressure Transmitters Outliers & Summary Ext. Stud.

Ext. Stud.

Ext. Stud.

Ext. Stud.

Ext. Stud.

Ext. Stud.

Ext. Stud.

Ext. Stud.

Ext. Stud.

Deviate Deviate Deviate Deviate Deviate Deviate Deviate Deviate Deviate Point 1 Point 2 Point 3 Point 4 Point 5 Point 6 Point 7 PointS Point 9 (0% Up)

(25% Up)

(50% Up)

(75% Up)

(100% Up)

(75% On)

(50% On)

(25% On)

(0% On) 0.214 0.181 0.102 0.258 0.497 0.339 0.427 0.366 0.187 0.017 0.264 0.350 0.176 0.095 0.181 0.180 0.111 0.034 0.278 0.641 0.806 0.800 0.790 0.606 1.140 0.569 0.043 0.017 0.065 0.020 0.013 0.066 0.024 0.098 0.111 0.187 0.081 0.065 0.063 0.149 0.015 0.055 0.015 0.229 0.120 0.116 0.099 0.185 0.258 0.175 0.181 0.067 0.111 0.187 0.017 0.099 0.063 0.068 0.066 0.024 0.098 0.026 0.043 0.116 0.099 0.020 0.013 0.256 0.024 0.067 0.026 0.034 0.214 0.346 0.267 0.176 0.256 0.103 0.262 0.196 0.341 0.111 0.181 0.022 0.087 0.047 0.126 0.040 0.000 0.034 0.145 0.297 0.226 0.060 0.098 0.000 0.073 0.136 0.034 0.214 0.017 0.146 0.068 0.066 0.134 0.150 0.026 0.187 0.608 0.675 0.515 0.664 0.658 0.654 0.592 0.706 0.494 0.081 0.065 0.185 0.176 0.095 0.181 0.098 0.111 0.043 0.706 0.428 0.433 0.420 0.417 0.496 0.427 0.451 0.417 0.180 0.888 0.972 1.777 2.398 1.709 0.892 0.824 0.197 0.180 0.065 0.598 1.071 1.784 1.205 0.757 0.026 0.273 0.509 0.428 0.433 0.420 0.497 0.418 0.427 0.366 0.494 0.071 0.288 0.325 0.290 0.151 0.173 0.262 0.357 0.028 0.214 0.017 0.102 0.095 0.095 0.024 0.098 0.111 0.110 0.180 0.099 0.020 0.176 0.066 0.181 0.067 0.026 0.120 0.081 0.148 0.020 0.231 0.256 0.213 0.015 0.059 0.043 0.214 0.181 0.020 0.176 0.146 0.181 0.098 0.111 0.187 0.017 0.065 0.476 1.126 1.594 1.079 0.480 0.026 0.034 0.509 0.148 0.311 0.149 0.307 0.213 0.315 0.229 0.341 0.677 0.840 0.846 1.071 1.140 0.969 1.005 0.876 0.486 0.111 0.165 0.135 0.052 0.002 0.181 0.015 0.017 0.026 0.214 0.065 0.063 0.095 0.336 0.339 0.015 0.144 0.110 1.558 0.641 0.476 0.475 0.015 0.291 0.480 0.654 1.194 0.017 0.017 0.020 0.013 0.095 0.024 0.015 0.026 0.110 0.017 0.148 0.102 0.258 0.095 0.055 0.067 0.144 0.034 0.116 0.264 0.102 0.068 0.175 0.103 0.067 0.026 0.034 0.081 0.065 0.063 0.068 0.146 0.055 0.098 0.111 0.043 0.155 0.099 0.077 0.052 0.042 0.103 0.130 0.119 0.149 0.121 0.017 0.121 0.160 0.232 0181 0.018 0.017 0.082 0.181 0.267 0.339 0.336 0.339 0.345 0.281 0.181 0.185 0.095 0.095 0.103 0.098 0.196 0.099 0.102 0.176 0.417 0.260 0.180 0.281 2.074 0.598 1.315 0.899 1.205 1.994 1.556 1.086 0.846 0.664 0.819 0.733 0.840 1.046 0.593 0.433 0.339 0.175 0.260 0.067 0.451 0.806 0.476 0.312 0.307 0.134 0.067 0.229 JC-Q1111-09019 Rev. 0 Page 111 of 134

DRIFT ANALYSIS ENGINEERING DEPARTMENT GRAND GULF NUCLEAR STATION Rosemount Range Codes 5 - 8 Gage Pressure Transmitters Outliers &Summary Ext. Stud.

Ext. Stud.

Ext. Stud.

Ext. Stud.

Ext. Stud.

Ext. Stud.

Ext. Stud.

Ext. Stud.

Ext. Stud.

Deviate Deviate Deviate Deviate Deviate Deviate Deviate Deviate Deviate Point 1 Point 2 Point 3 Point 4 Point 5 Point 6 Point 7 PointS Point 9 (0% Up)

(25% Up)

(50% Up)

(75% Up)

(100% Up)

(75% On)

(50% On)

(25"1. On)

(0% On) 0.181 0.267 0.217 0.433 0.087 0.032 0.230 0081 0.148 0.228 0.149 0.146 0.134 0.150 0.144 0.043 0.180 0.230 0.146 0.149 0.227 0.134 0.150 0.144 0.120 0.081 0.065 0.020 0.068 0.146 0.213 0.150 0.144 0.120 0.017 0.017 0.020 0.013 0.095 0.024 0.015 0.059 0.034 0.180 0065 0.020 0.013 0.015 0.055 0.015 0.026 0.120 0.214 0.264 0.267 0.176 0.256 0260 0.345 0.281 0.341 0.214 0.065 0.102 0.013 0.015 0.024 0.015 0.059 0.034 0.081 0.181 0.350 0.339 0.658 0.339 0.262 0.026 0.120 0.214 0.099 0.020 0.176 0.175 0.181 0.098 0.111 0.494 0.214 0.181 0.267 0.176 0.146 0.181 0.262 0.196 0.120 1.164 1.300 1.302 1.451 1.192 1.473 1.387 1.334 0.887 2.183 2.074 2.085 2.227 2.266 2.080 2.184 2.049 1.499 0.509 0.593 0.763 0.827 0.658 0.733 0.840 0.791 0.494 0.214 0.181 0.102 0013 0.095 0.024 0.015 0.059 0.110 0.377 0.724 0.806 0.800 0.709 0.528 0.562 0.654 0.273 0.116 0.510 0.350 0.502 0.658 0.418 0.345 0.281 0.043 14.652 14.957 14.683 13.739 12.531 13.920 14.584 14.935 15.238 0.313 0.148 0.559 0.882 1.594 1.473 0.810 0.229 0.187 0.967 0.477 0.020 0.502 0.899 0.496 0.015 0.484 0.734 1.090 0.897 1.432 1.324 1.398 1.205 1.211 1.054 0.624 0.017 0.017 0.102 0.095 0.015 0.024 0.015 0.026 0.034 0.116 0.148 0.146 0.149 0.227 0.134 0.232 0.144 0.110 0.574 0.065 0.146 0.068 0.146 0.213 0.232 0.314 0.273 0.608 0.181 0.267 0.095 0.256 0.260 0.427 0.536 0.341 0.017 0.148 0.063 0.068 0.066 0.055 0.067 0.314 0.120 3.758 2.979 2.993 2.943 2.749 2.781 2.737 3.001 3.103 2149 1.217 0.228 0.909 2.025 0.969 0.232 1.079 1.731 0.091 1.374 2.045 3.486 4.545 3.364 1.882 1.326 0.179 0.081 0.099 0.102 0.095 0.175 0.103 0.015 0.111 0.034 0.116 0.148 0.146 0.312 0.307 0.213 0.232 0.144 0.034 0.017 0.017 0.146 0.013 0.015 0.024 0.015 0.059 0.043 0.214 0.264 0.350 0.258 0.256 0.339 0.180 0.281 0.110 0.377 0.230 0.063 0.231 0.307 0.291 0.067 0.144 0.273 0.475 0.099 0.063 0.258 0.497 0.339 0.180 0.196 0.197 0.017 0.264 0.515 0.502 0.256 0.260 0.345 0.281 0.043 0.180 0.099 0063 0.068 0.015 0.103 0.150 0.111 0.187 0.116 0.099 0.185 0.258 0.336 0.260 0.180 0.111 0.110 0.081 0017 0.020 0.013 0.015 0.024 0.067 0.026 0.043 0.116 0.065 0.146 0.231 0.307 0.213 0.067 0.059 0.110 0.017 0.017 0.020 0.013 0.066 0.024 0.015 0.111 0.034 1.002 0.675 0.598 0.827 0.738 0.812 0.757 0.706 0.801 JC-Q1111-09019 Rev. 0 Page 112 of 134

DRIFT ANALYSIS ENGINEERING DEPARTMENT GRAND GULF NUCLEAR STATION Rosemount Range Codes 5 - 8 Gage Pressure Transmitters Outliers & Summary Ext. Stud.

Ext. Stud.

Ext. Stud.

Ext. Stud.

Ext. Stud.

Ext. Stud.

Ext. Stud.

Ext. Stud.

Ext. Stud.

Deviate Deviate Deviate Deviate Deviate Deviate Deviate Deviate Deviate Point 1 Point 2 Point 3 Point 4 Point 5 Point 6 Point 7 PointS Point 9 (0% Up)

(25% Up)

(50% Up)

(75% Up)

(100% Up)

(75%Dn)

(5O%Dn)

(25%Dn)

(O%Dn) 1.361 2.451 3.615 4.625 5.695 4.467 3.449 2.694 1.118 0.081 0.065 0.020 0.013 0.015 0.055 0.015 0.059 0.043 0.116 0.099 0.020 0.013 0.015 0.103 0.015 0.111 0.110 0.081 0.065 0.020 0.013 0.015 0.024 0.015 0.059 0.043 0.509 0.428 0.598 0.502 0.417 0.418 0.592 0.536 0.417 0.116 0.065 0.476 0.638 0.629 0.449 0.480 0.026 0.110 0.411 0.264 0.433 0.827 0.899 0.812 0.592 0.281 0.264 0.475 0.017 0.020 0.013 0.066 0.055 0.150 0.144 0.197 0.116 0.099 0.020 0013 0.015 0.024 0.015 0.026 0.110 0.116 0.099 0.102 0.013 0.095 0.024 0.015 0.111 0.110 0.081 0.148 0.146 0.149 0.307 0.134 0.150 0.144 0.043 0.706 0.675 0.763 0.746 0.658 0.654 0.675 0.706 0.571 0.509 0.428 0.598 0.664 0.658 0.654 0.592 0.451 0.417 0.180 0.395 0.559 0.638 0.468 0.449 0.645 0.314 0.273 0.509 0.264 0.515 0.583 0.336 0.339 0.510 0.536 0.341 0.411 0.346 0.350 0.258 0.256 0.260 0.180 0.281 0.187 0.081 0.148 0.228 0.149 0.066 0.055 0.067 0.059 0.034 0.116 0.181 0.102 0.176 0.256 0.260 0.262 0.111 0.110 0.214 0.017 0.020 0.013 0.066 0.055 0.015 0.026 0.187 0.214 0.264 0.350 0.176 0.146 0.181 0.180 0.281 0.417 0.967 0.641 0.724 0.719 0.709 0.606 0.727 0.824 0.887 0.081 0.017 0.063 0.149 0.227 0.213 0.232 0.144 0.043 0.017 0.099 0.020 0.068 0.095 0.024 0.015 0.026 0.034 0.017 0.017 0.020 0.095 0.015 0.024 0.098 0.026 0.034 0.017 0.017 0.020 0.013 0.015 0.024 0.015 0.059 0.034 0.805 0.675 0.680 0.502 0.336 0.418 0.592 0.621 0.647 0.313 0.346 0.185 0.095 0.015 0.103 0.180 0.196 0.417 0.633 0.460 0.127 0.396 0.360 0.339 0.007 0.297 0.412 0.175 0.412 0.243 0.125 0.090 0.055 0.188 0.094 0.135 0.017 0.099 0.102 0.095 0.095 0.055 0.067 0.026 0.110 0.116 0.017 0.102 0.095 0.066 0.024 0.180 0.026 0.034 0.116 0.099 0.020 0.013 0.175 0.024 0.067 0.026 0.043 0.278 0.065 0.020 0.013 0.015 0.055 0.015 0.144 0.197 JC-Q1111-09019 Rev. 0 Page 113 of 134

DRIFT ANALYSIS ENGINEERING DEPARTMENT GRAND GULF NUCLEAR STATION Rosemount Range Codes 5 - 8 Gage Pressure Transmitters Outliers &Summary Ext. Stud.

Ext. Stud.

Ext. Stud.

Ext. Stud.

Ext. Stud.

Ext Stud.

Ext. Stud.

Ext. Stud.

Ext. Stud.

Deviate Deviate Deviate Deviate Deviate Deviate Deviate Deviate Deviate Point 1 Point 2 Point 3 Point 4 Point 5 Point 6 Point 7 Point 8 Point 9 (0% Up)

(25% Up)

(50% Up)

(75% Up)

(100% Up)

(75% On)

(SO'Y. On)

(25% On)

(0% On) 0.081 0.065 0.063 0.149 0.066 0.055 0.150 0.026 0.110 0.081 0.017 0.020 0.095 0.175 0.024 0.015 0.026 0.043 0.017 0.017 0.102 0.176 0.095 0.181 0.180 0.111 0.034 0.116 0.017 0.063 0.149 0.146 0.134 0.150 0.059 0.034 0.081 0.017 0.020 0.013 0.066 0.024 0.015 0.026 0.034 0.017 0.099 0.102 0.176 0.175 0.181 0.098 0.111 0.034 0.214 0.264 0.185 0.176 0.015 0.103 0.180 0.196 0.187 0.081 0.148 0.020 0.013 0.175 0.103 0.015 0.059 0.043 0.116 0.099 0.102 0.176 0.175 0.181 0.098 0.111 0.110 0.081 0.065 0.063 0.068 0.015 0.055 0.067 0.059 0.043 0.017 0.017 0.020 0.013 0.015 0.024 0.015 0.026 0.034 0.017 0.017 0.020 0.095 0.175 0.103 0.015 0.026 0.110 0.017 0.099 0.102 0.013 0.015 0.103 0.098 0.111 0.034 0.017 0.017 0.146 0.013 0.066 0.055 0.150 0.059 0.034 0.017 0065 0.185 0.095 0.095 0.103 0.098 0.026 0.043 0.116 0.017 0.020 0.013 0.015 0.024 0.098 0.111 0.034 0.116 0.099 0.102 0.095 0.095 0.103 0.098 0.059 0.110 0.017 0.017 0.102 0.013 0.146 0.024 0.067 0.026 0.034 0.081 0.017 0.063 0.013 0.095 0.055 0.067 0.059 0.043 0.081 0.065 0.063 0.068 0.146 0.024 0.098 0.026 0.043 0.214 0.264 0.350 0.258 0.417 0.260 0.262 0.281 0.187 0.017 0.065 0.146 0.095 0.227 0.055 0.150 0.144 0.043 0.180 0.065 0.063 0.149 0.095 0.024 0.098 0.026 0.043 0.017 0.099 0.185 0.095 0.095 0.103 0.098 0.026 0.034 0.017 0.065 0.146 0.068 0.066 0.055 0.150 0.059 0.043 0.180 0.065 0.020 0.068 0.066 0.055 0.015 0.026 0.043 0.214 0.099 0.020 0.095 0.015 0.103 0.015 0.026 0.110 0.180 0.017 0.020 0.013 0.175 0.055 0.067 0.059 0.034 0.116 0.065 0.063 0.013 0.066 0.103 0.015 0.026 0.043 0.017 0.148 0.228 0.312 0.307 0.291 0.232 0.144 0.034 Equation for Each Studentized Deviate: T"IDrift-MeanVStd. Dev.

JC-Q1111-09019 Rev. 0 Page 114 of 134

DRIFT ANALYSIS ENGINEERING DEPARTMENT GRAND GULF NUCLEAR STATION Rosemount Range Codes 5 - 8 Gage Pressure Transmitters Outliers &Summary JC-Q1111-09019 Rev. 0 Page 115 of 134 Final Drift Data Final Drift Data Final Drift Data Final Drift Data Final Drift Data Final Drift Data Final Drift Data Final Drift Data Final Drift Raw Data Tag 10 (Pl 1)

(Pt2)

(Pl3)

(Pt4)

(Pt5)

(Pt6)

(Pl 7)

(Pt8)

Data (Pl 9)

Cal Interval 10#

(0% Up)

(25% Up)

(50% Up)

(75% Up)

(100% Up)

(75% On)

(50% On)

(25% On)

(0% On)

(Days)

(%Span)

(%Span)

(%Span)

(%Span)

(%Span)

("I.Span)

(%Span)

(%Span)

(%Span) 1 1B21N201A 0.0000 0.0000 0.0000 0.0625 0.0625 0.0625 0.0625 0.0000 0.0000 659 3

1B21N201A 0.0625 0.0625 0.0000

-0.0625

~.1250

-0.0625 0.0000 0.0625 0.0625 658 5

1B21N201A 0.0000 0.1875 0.3125 0.5625 1.1875 0.6875 0.3125 0.2500

-0.0625 546 7

1B21N201A 0.0000 0.0625 0.1250 0.1875 0.1875 0.1250 0.0625 0.0625 0.0625 533 9

1B21N201A

-0.0625 0.1875 0.1250 0.0625 0.0625 0.1250 0.1875 0.2500

-0.1250 580 11 1B21N201A 0.4500 0.0625

-0.1938

-0.1375

~.O125

-0.0563

-0.0812 0.0813 0.4313 544 13 1B21N201A

-0.0750

-0.0625 0.1313 0.0750

~.0500 0.1188 0.0812

-0.0813

-0.0562 555 17 1B21N201B 0.0625 0.0625 0.0000 0.0000 0.0000 0.0000 0.0000 0.0625 0.0625 612 19 1B21N201B 0.0000 0.0625

-0.0250 0.0625 0.0000 0.0000 0.0000 0.0625 0.0000 536 21 1B21N201B 0.0000 0.0000 0.0000

-0.1250 0.0625

-0.0625 0.0000

-0.0625 0.0000 583 23 1B21N201B 0.0000

-0.0625

-0.0375 0.0000

~.1250 0.0000

-0.0625

-0.0625 0.0000 601 25 1B21N201B 0.0000 0.1875 0.0625 0.2500 0.2500 0.2500 0.1875 0.2500 0.1250 630 27 1B21N201B 0.0625

-0.1250 0.0000

-0.1875

~.1875

-0.1875

-0.1250

-0.1250

-0.0625 549 29 1B21N201B 0.0000 0.0000 0.0625 0.1250 0.0000 0.0000

-0.1250

-0.0625

-0.0625 535 31 1B21N201B 0.0625 0.0625

-0.1250

-0.1875

~.0625 0.0000 0.0625 0.1250 0.0625 568 35 1C61N102 0.0625 0.0000

-0.0625 0.0000

~.1250

-0.0625

-0.0625 0.0000 0.0625 544 37 1C61N102 0.1250 0.1250 0.1250 0.0625 0.0625 0.0625 00625 0.1875 0.1250 533 39 1C61N102 0.0625 0.0625 0.1250 0.1250 0.1250 0.1875 0.1250 0.0625 0.0625 589 41 1C61N102

-0.2500

-0.1875

-0.1875

-0.1250

~.0625

-0.1250

-0.1875

-0.2500

-0.2500 531 43 1C61N102 0.0000

-0.0625

-0.0625

-0.0625

~.0625

-0.0625 0.0000 0.0000 0.0000 545 45 1C61N102 0.1250 0.1250 0.0000 0.1250 0.1250 0.1250 0.0625 0.1250 0.0625 542 47 1C61N102

-0.1875

-0.0625 0.0625

-0.0625

~.0625 0.0000 0.0625 0.0000

-0.1250 505 51 1E12N053A 0.0000 0.0000 00625 0.0625 0.0625 0.0000 0.0625 0.0625

-0.0625 544 53 1E12N053A

-0.1250

-0.0625

-0.1875

-0.1250

~.125O

-0.1250

-0.0625

-0.0625

-0.0625 534 55 1E12N053A 0.0000 0.0000 0.1250 0.0625 0.0625 0.0625 0.0000

-0.0625 0.0000 531 57 1E12N053A 0.0000 0.0000

-0.0625

-0.0625

~.0625

-0.0625

-0.0625 0.0000 0.0625 531 59 1E12N053A

-0.0625

-0.1875

-0.1875

-0.1875

~.1875

-0.1875

-0.1875

-0.1250

-0.0625 534 61 1E12N053A

-0.0625 0.0625

-0.0625 0.0000

~.0625 0.0625 0.0000 0.0625

-0.0625 548 63 1E12N053A 0.0625 0.0000 0.0000

-0.0625 0.1250 0.0000 0.0625 0.0625 0.0625 574 65 1E12N053A

-0.1187

-0.0625 0.0000

-0.1125 0.1750

-0.0062

-0.0187

-0.0937

-0.0562 573 69 1E12N053B

-0.1250

-0.0625

-0.0625

-0.0625

~.0625

-0.1875

-0.0625

-0.0625

-0.3125 564 71 1E12N053B

-0.2500 0.0625 0.0625 0.0625 0.1250 0.1250 0.0625 0.0625 0.0000 547 73 1E12N053B 0.0000 0.0000

-0.0625

-0.1250

~.125O

-0.1875

-0.1250

-0.0625 0.0000 558 75 1E12N053B 0.0000 0.0000 0.0625 0.0000 0.0000 0.0000 0.0000

-0.0625 0.0000 547 77 1E12N053B

-0.1250

-0.1250

-0.1250

-0.0625

.0.0625

-0.0625

-0.1250

-0.0625

-0.1875 491 79 1E12N053B 0.0000 0.0625

-0.1250

-0.1250 0.0000

-0.0625 0.0625 0.0625 0.0625 657 81 1E12N053B 0.1250

-0.1250 0.0625 0.0000

~.0625

-0.0625

-0.1250

-0.1250 0.1875 560 83 1E12N053B

-0.1000

-0.0375

-0.1938

-0.0813

.0.3000

-0.1187

-0.0938

-0.0437

-0.1937 575

DRIFT ANALYSIS ENGINEERING DEPARTMENT GRAND GULF NUCLEAR STATION Rosemount Range Codes 5 - 8 Gage Pressure Transmitters Outliers &Summary JC-Q1111-09019 Rev. 0 Page 116 of 134 Final Drift Data Final Drift Data Final Drift Data Final Drift Data Final Drift Data Final Drift Data Final Drift Data Final Drift Data Final Drift Raw Data TagiD (Pt 1)

(Pt2)

(Pt3)

(Pt4)

(Pt5)

(Pt6)

(Pt7)

(Pt8)

Data (Pt9)

Cal Interval II>>

(0% Up)

(25% Up)

(50% Up)

(75°;' Up)

(100% Up)

(75% On)

(50% On)

(25% On)

(0% On)

(Days)

(%Span)

(%Span)

(%Span)

(%Span)

(%Span)

(%Span)

(%Span)

(%Span)

(%Span) 87 lE12N053C

-0.0625

-0.0625

-0.1250

-0.0625

-0.0625

-0.0625

-0.1250

-0.0625 0.0000 542 89 1E12N053C 0.0625 0.1250 0.1875 0.1250 0.1250 0.0625 0.1250 0.0625 0.0000 602 91 1E12N053C

-0.1875

-0.1250

-0.0625

-0.0625

-0.0625 0.0000

-0.0625

-0.0625

-0.1250 602 93 1E12N053C 0.0625 0.0000

-0.0625

-0.0625 0.0000

-0.0625 0.0000 0.0000 0.0625 656 95 1E12N053C 0.0000

-0.0625

-0.0625

-0.0625

-0.0625

-0.0625

-0.0625

-0.0625 0.0000 630 97 1E12N053C 00000 0.0625 0.0625 0.1875 0.0000 00625 0.1250 0.1250 0.0000 631 99 1E12N053C 0.0000

-0.0625

-0.0625

-0.1875 0.0000

-0.0625

-0.1250

-0.1875 0.0000 586 101 1E12N053C

-0.0812

-0.1313 0.0125

-0.1375

-0.1250 0.1625

-0.1250 0.0563

-0.1125 575 105 1E12N055A 0.1250 0.1875 0.1875 0.1875 0.0625 0.1875 0.1250 0.1875 0.1250 540 107 1E12N055A

-0.0625

-0.0625

-0.0625

-0.1250

-0.0625

-0.1250

-0.0625

-0.1250

-0.0625 655 109 1E12N055A 0.0000 0.0625 0.0000 0.1250 0.0625 0.1250 0.0625 0.0625 0.0000 605 111 1E12N055A

-0.0625

-0.1250

-0.1250

-0.2500

-0.1250

-0.1875

-0.1875

-0.1250 0.0625 502 113 1E12N055A

-0.0625

-0.0625

-0.1250

-0.0625

-0.1250

-0.0625

-0.0625

-0.1250

-0.1250 544 115 1E12N055A

-0.0625 0.1250 0.0000 0.1250 0.1875

-0.0625

-0.1250 0.1250

-0.1250 520 117 1E12N055A

-0.0812 0.0312 0.1875 0.2938 0.2750 0.2813 0.2312 0.4063

-0.0563 542 119 1E12N055A 0.0563 0.0000 0.0500 0.0313 0.1000 0.0250

-0.0500

-0.2312 0.0125 589 123 1E12N055B 0.0000 0.1250 0.1250 0.0625

-0.0625 0.0625 0.1250 0.1250 0.0000 602 125 1E12N055B

-0.0625

-0.0625

-0.0625

-0.1250

-0.0625

-0.1250

-0.0625

-0.0625

-0.0625 547 127 1E12N055B

-0.1250

-0.2500

-0.1875

-0.2500

-0.2500

-0.2500

-0.2500

-0.2500

-0.1250 558 129 1E12N055B

-0.0625

-0.0625

-0.0625

-0.0625

-0.1250

-0.0625 0.0000 0.0000

-0.0625 548 131 1E12N055B 0.0625

-0.1875

-0.2500

-0.3125

-0.2500

-0.2500

-0.1875

-0.1875 0.0000 533 133 1E12N055B 0.0000

-0.0625 0.0625

-0.1250

-0.3125 0.0000 0.1250 0.0625 0.0000 546 135 1E12N055B 0.0000

-0.0625

-0.2250

-0.1063 0.1312

-0.2813

-0.2312

-0.2437

-0.0062 559 137 lE12N055B 0.1250 0.0625 0.1625 0.1688

-0.1937 0.2813 0.1062 0.2437 0.0688 587 141 1E12N055C 0.0000 0.1250 0.1250 0.1250 0.1250 0.1250 0.1250 0.1875 0.0000 601 143 1E12N055C 0.1875

-0.0625

-0.0625 0.0000 0.0000 0.0000

-0.0625

-0.0625 0.1875 547 145 1E12N055C

-0.5000

-0.3125

-0.3750

-0.4375

-0.3750

-0.4375

-0.4375

-0.1875

-0.4375 558 147 1E12N055C

-0.0625 0.0000 0.0000

-0.0625

-0.0625

-0.0625

-0.0625

-0.0625

-0.0625 548 149 1E12N055C 0.0625 0.0000 0.0000 0.0625 0.1875 0.0625 0.0625 0.0625 0.0625 504 151 1E12N055C 0.0000

-0.0625

-0.1250

-0.0625

-0.0625

-0.0625

-0.0625

-0.0625

-0.0625 574 153 1E12N055C

-0.0625

-0.1250

-01875

-0.1250

-0.1250

-0.1875

-0.3750

-0.1250 0.0000 559 155 1E12N055C 0.0625 0.1875 0.3750 0.2500 0.1250 0.3125 0.4375 0.2500 0.0000 588 159 1E12N056A 0.1250 0.1250 0.1250 0.1250 0.1250 0.1250 0.0625 0.1250 0.1250 539 161 1E12N056A

-0.3125

-0.3125

-0.3125

-0.3125

-0.3125

-0.3125

-0.3125

-0.3125

-0.2500 654 163 1E12N056A

-0.1250 0.0625 0.0625 0.1250 0.0000 0.0625 0.0000 0.0000

-0.1250 606 165 1E12N056A 0.0625 0.0000

-0.0625

-0.1250

-0.0625

-0.1250

-0.0625 0.0625 0.0000 530 167 1E12N056A

-0.0625

-0.1250 0.0625

-0.0625 0.0625 0.0000 0.1250

-0.0625

-0.0625 544 169 1E12N056A 0.0625

-0.3750

-0.5000

-0.6250

-0.5625

-0.6875

-0.6875

-0.4375

-0.0625 492 171 1E12N056A 0.0312 0.1125 0.0625 0.1437 0.1812 0.2188 0.1812 0.0875

-0.0063 542 173 1E12N056A

-0.1188

-0.0375 0.0250 0.0187

-0.0500 0.0250 0.0312

-0.0687

-0.0188 589 177 1E12N056B 0.1875 0.3750 0.3125 0.2500 0.1875 0.3125 0.3750 0.3750 0.1250 577 179 1E12N056B

-0.3125

-0.5000

-0.5000

-0.5000

-0.3125

-0.5625

-0.5000

-0.4375

-0.3750 544 181 1E12N056B

-0.0625 0.0000

-0.0625

-0.0625

-0.2500 0.0000

-0.0625

-0.0625 0.0000 546

DRIFT ANALYSIS ENGINEERING DEPARTMENT GRAND GULF NUCLEAR STATION Rosemount Range Codes 5 - 8 Gage Pressure Transmitters Outliers &Summary JC-Q1111-09019 Rev. 0 Page 117 of 134 Final Drift Data Final Drift Data Final Drift Data Final Drift Data Final Drift Data Final Drift Data Final Drift Data Final Drift Data Final Drift Raw Data Tag ID (Pt 1)

(Pt2)

(Pt 3)

(Pt4)

(Pt5)

(Pt6)

(Pt7)

(Pt8)

Data (Pt 9)

Cal Interval 10#

(0% Up)

(25"1. Up)

(50"10 Up)

(75"1. Up)

(100% Up)

(75% Dn)

(50"loDn)

(25"1. Dn)

(O"l.Dn)

(Days)

("IoSpan)

("IoSpan)

("loSpan)

("I.Span)

("IoSpan)

("IoSpan)

(%Span)

("I.Span)

(%Span) 183 1E12N056B 00625 0.0000 0.1250 0.1250 0.1250 0.1250 0.1250 0.0000 0.0625 631 185 1E12N056B

-0.1250

-0.5625 0.0000

-0.7500

-0.8750

-0.8125

-0.6875

-0.5000

-0.1250 547 187 1E12N056B

-0.0625 0.1250 0.3125 0.6875 0.5625 0.6250 0.2500 0.3750 0.0625 503 189 1E12N056B 0.0437

-0.0812

-0.1500

-0.3500

-0.0937

-0.2625

-0.0750 0.0375

-0.0563 560 191 1E12N056B

-0.0437 0.2062 0.2750 0.2250

-0.0938 0.1375 0.3250 0.0875 0.0563 587 195 1E12N056C

-0.3125

-0.4375

-0.4375

-0.4375

-0.5625

-0.5000

-0.4375

-0.5000

-0.3750 637 197 1E12N056C

-0.0625 0.0000 0.0000 0.0000 0.1250 0.0000

-0.0625 0.0000 0.0000 545 199 1E12N056C 0.0625 0.0625 0.0625 0.1875 0.0625 0.1875 0.1250 0.0625 0.0000 560 201 1E12N056C 0.0000 0.0000

-0.1250

-0.1875

-0.2500

-0.1875

-0.1875

-0.1250 0.0000 616 203 1E12N056C 0.0625 0.1250 00625 0.0625 0.0625 0.0625 0.0625 0.0000 0.0625 476 205 1E12N056C

-0.1250

-0.1875

-0.0625

-0.1250

-0.1250

-0.1250

-0.1250

-0.0625

-0.1250 574 207 1E12N056C 0.2250

-0.0875

-0.5063

-0.1563

-0.2562

-0.3812

-0.4187

-0.1188 0.0937 560 209 1E12N056C

-0.2250

-0.0375 0.3812 0.0938 0.0687 0.2562 0.4187 0.1813

-0.0937 587 213 1E12N057 0.0000

-0.0625 0.0000

-0.0625

-0.0625

-0.1250

-0.0625

-0.0625

-0.0625 655 215 1E12N057

-0.0625 0.0000 0.0625 0.0625 0.0625 0.0625 0.1250 0.0625 0.0000 646 217 1E12N057 0.0000 0.0000

-0.0625

-0.0625

-0.0625

-0.0625

-0.1875

-0.0625 0.0000 545 219 1E12N057 0.0000 0.1250 0.1250 0.1250 0.0625 0.0625 0.1250 0.1250 0.0625 531 221 lE12N057 0.0000

-0.0625

-0.1250

-0.0625

-0.0625 0.0625

-0.1250

-0.0625

-0.0625 534 223 1E12N057 0.0000 0.0000 0.0625 0.0000 0.0625

-0.0625 0.1250 0.0000 0.0000 377 225 1E12N057

-0.1250

-0.1875

-0.1250

-0.2500

-0.2500

-0.1875

-0.3125

-0.1875

-0.1875 557 227 lE12N057

-0.1500

-00875

-0.2062

-0.1625

-0.1375

-0.1250

-0.0812

-0.0500 0.0125 551 231 lE12N058A

-0.0625

-0.1250

-0.1250

-0.0625

-0.0625 0.0000

-0.1875

-0.1250

-0.0625 670 233 1E12N058A 0.0625 0.0000 0.0625 0.0000 0.0000 0.0000 0.1250 0.0000 0.0625 603 235 1E12N058A 0.0000 0.0000

-0.0625 0.0000 0.0000 0.0625 0.0000 0.1250

-0.0625 543 237 1E12N058A

-0.0625 0.0000 0.0000 0.0625 0.0000 0.0000 0.0000

-0.0625 0.0000 560 239 1E12N058A 0.0000

-0.1250

-0.1875

-0.3125

-0.3750

-0.2500

-0.0625

-0.1875 0.0000 487 241 1E12N058A

-0.0625 0.1250 0.0625 0.0625 0.0625 0.0000 0.0625

-0.0625 594 243 1E12N058A 0.1250 0.0000 0.0625 0.0000 0.1875 0.0625 0.0625 0.0625 0.1250 489 245 1E12N058A

-0.3125

-0.0625

-0.0625

-0.1875

-0.2500

-0.1250

-0.1250

-0.1250

-0.3125 602 249 1E12N058B 0.0000

-0.1250

-0.1875

-0.1250

-0.0625

-0.1250

-0.1875

-0.2500 0.0000 589 251 1E12N058B

-0.1250 0.0000

-0.0625 0.0000 0.0625 0.0000 0.0625 0.1250 0.1250 547 253 1E12N058B 0.0000 0.1250 0.1875 0.1250 0.1250 0.1250 0.1250 0.0625 0.0000 560 255 1E12N058B 0.1250 0.0000

-0.0625

-0.0625

-0.0625

-0.1250

-0.1875

-0.1250 0.0000 532 257 1E12N058B 0.0625 0.0625 0.0625 0.0000 0.0625 0.1875 0.1250 0.1250 0.1250 545 259 1E12N058B

-0.1875

-0.0625 0.0625 0.1250

-0.1875

-0.0625 0.1250 0.0000

-0.1250 535 261 1E12N058B

-0.0250

-0.1750

-0.2875

-0.2313 0.0250

-0.1125

-0.2125

-0.1000 0.0000 529 263 1E12N058B 0.2125 0.1750 0.1625 0.1063 0.1625 0.0500 0.0875 0.1000 0.1250 591 267 1E12N058C

-0.2500

-0.1875

-0.1875

-0.1250

-0.2500

-0.1250

-0.1250

-0.2500

-0.1875 602 269 1E12N058C

-0.1875

-0.1250

-0.1250

-0.2500

-0.2500

-0.1875

-0.2500

-0.2500

-0.2500 570 271 1E12N058C 0.0625 0.0000 0.0625 0.1250 0.0625 0.0000 0.0000 0.0625 0.1250 562 273 1E12N058C 0.0625 0.0625 0.0000 0.0625 0.0625 0.0000 0.0625 0.0000 0.0000 574 275 1E12N058C 0.0000

-0.0625

-0.0625

-0.1250

-0.0625 0.0625 0.0625 0.1250 0.1250 462

DRIFT ANALYSIS ENGINEERING DEPARTMENT GRAND GULF NUCLEAR STATION Rosemount Range Codes 5 - 8 Gage Pressure Transmitters Outliers &Summary JC-Q1111-09019 Rev. 0 Page 118 of 134 Final Drift Data Final Drift Data Final Drift Data Final Drift Data Final Drift Data Final Drift Data Final Drift Data Final Drift Data Final Drift Raw Data (Pt 1)

(Pt2)

(Pt3)

(Pt4)

(Pt5)

(Pt6)

(Pt7)

(Pt8)

Data (Pt 9)

Cal Interval 10#

Tag 10 (0% Up)

(25% Up)

(SO°.4 Up)

(75% Up)

(100% Up)

(75% On)

(50"0 On)

(25% On)

(0% On)

(Days)

(%Span)

(%Span)

(%Span)

(%Span)

(%Span)

(%Span)

(%Span)

(%Span)

(%Span) 277 1E12N058C

-0.1250

-0.1250

-0.0625

-0.1875

-o.37SO

-0.2500

-0.3125

-0.2500

-0.1250 535 279 1E12N058C 0.0000

-0.1875

-0.2500

-0.1250

-0.0625

-0.1250

-0.1250

-0.0625 0.0000 515 281 1E12N058C 0.1875 0.5000 0.6250 0.6250 0.62SO 0.5000 0.8750 0.4375 0.0625 558 285 1E21N050 0.0000 0.0625 0.0000 0.0000 0.0625 0.0000

-0.0625

-0.0625

-0.1250 645 287 1E21N050 0.0625 0.0625 0.0625 0.1250 0.0000 0.0625 0.0000 0.1875 0.1250 559 289 1E21N050

-0.0625

-0.0625

-0.1250

-01875

-o.12SO

-0.1250 0.0625

-0.0625

-0.1250 662 291 1E21N050 0.0000

-0.0625 0.0625 0.0625 0.0625 0.0000

-0.0625 0.0000 0.0625 643 293 1E21N050

-0.0625

-0.0625 0.0000 0.0000

-0.1875 0.0000 0.0625 0.0000 0.0000 544 295 1E21N050

-0.1250

-0.2500

-0.1875

-0.1250

-0.1875

-0.0625

-0.1875

-0.1250

-0.2500 549 297 1E21N050 0.0813 0.1500 0.0313

-0.0563

-o.02SO

-0.0812

-0.0188 0.0188 0.0000 554 299 1E21N050

-0.0813

-0.2125

-0.1563 0.0563 0.0875 0.0187

-0.0437

-0.0813 0.0000 589 303 1E21N052

-0.1250 0.0000 0.1250 0.0625 0.0625 0.1250 0.1250 0.0000

-0.1250 627 305 1E21N052

-0.3750

-0.5000

-0.3750

-0.5000

-o.SOOO

-0.5000

-0.4375

-0.5000

-0.3750 559 307 1E21N052 0.0625 0.0625

-0.1250

-0.1250

-0.0625

-0.1250

-0.0625

-0.0625 0.0625 577 309 1E21N052

-0.4375

-0.3125

-0.3125

-0.3125

-0.3125

-0.3750

-0.3125

-0.3125

-0.3125 657 311 1E21N052 0.1250 0.6875 0.7500 1.3750 1.8750 1.3750 0.6875 0.6250 0.1875 532 313 1E21N052 0.1250 0.0625

-0.4375

-0.8125

  • 1.3750

-0.9375

-0.5625 0.0000 0.2500 486 315 1E21N052

-0.3125

-0.3125

-0.3125

-0.3125

-0.3750

-0.3125

-0.3125

-0.2500

-0.3750 550 317 1E21N052 0.0562

-0.2062

-0.2312

-0.2125

-0.1063

-0.1188

-0.1875

-0.2437 0.0500 562 321 1E21N053

-0.1250 0.0000

-0.0625

-0.0625

-0.0625 0.0000

-0.0625

-0.0625

-0.0625 543 323 1E21N053 0.1250

-0.0625 0.0000

-0.1250 0.0625

-0.1250 0.0625 0.0000 0.1250 548 325 1E21N053 00625 0.1250 0.0000 0.1875

-0.1875 0.1875 0.0000 0.0625 0.0625 570 327 1E21N053

-0.1250

-0.1250 0.0000

-0.1250 0.12SO

-0.1250

-0.0625

-0.0625

-0.1250 550 329 1E21N053 0.0000 0.0625 0.3750 0.8750 1.2500 0.8750 0.3750 0.0000 0.0000 558 331 1E21N053

-0.3125 0.1250 0.2500 0.1250 0.2500 0.1875 0.2500 0.1875

-0.2500 487 333 1E21N053

-0.4187

-0.6250

-0.6250

-0.8125

-0.8750

-0.7500

-0.7500

-0.6250

-0.3687 549 335 1E21N053 0.0812

-0.1125

-0.0875 0.0500 0.0125 0.1625 0.0000 0.0063 0.0062 563 339 1E21N054

-0.1250 0.0625 0.0625

-0.0625

-0.2500

-0.2500 0.0000 0.1250

-0.0625 673 341 1E21N054 1.0000 0.5000 0.3750 0.3750 0.0000 0.2500 0.3750 0.5000 1.0000 563 343 1E21N054 0.0000 0.0000 0.0000 0.0000

-0.0625 0.0000 0.0000 0.0000

-0.0625 644 345 1E21N054 0.0000 0.1250

-0.0625

-0.1875

-0.0625 0.0625 0.0625 0.1250 0.0000 601 347 1E21N054

-0.0625

-0.1875

-0.0625 0.0625

-0.1250

-0.0625 0.0625 0.0000 0.0000 516 349 1E21N054 0.0625 0.0625 0.0625 0.0625 0.1250 0.0625

-0.0625

-0.0625 0.0625 534 351 1E21N054

-0.0875

-0.0625

-0.0438 0.0500 0.0437

-0.0625

-0.0875

-0.0687

-0.0938 561 353 1E21N054 0.0875 0.0000 0.1063

-0.1125

-0.1688

-0.1250 0.0250 0.0062 0.0938 543 357 1E22N050

-0.1250

-0.1875

-0.2500

-0.2500

-0.2500

-0.2500

-0.1875 630 359 1E22N050

-0.1250

-0.1250

-0.0625

-0.0625

-0.0625

-0.0625

-0.1250 590 361 1E22N050

-0.0625

-0.0625

-0.1250

-0.3125

-0.1875

-0.1250

-0.1875 530 363 1E22N050

-1.5625

-0.4375

-1.0000

-0.6875

-0.9375

-1.5000

-1.1250 616 365 1E22N050

-0.8125

-0.6250

-0.5000

-0.6250

-0.5625

-0.6250

-0.7500 532 367 1E22N050

-0.4375

-0.3125

-0.2500

-0.1250

-0.1875 0.0625

-0.3125 504 369 1E22N050 0.6250 0.3750 0.2500 0.2500 0.1250 0.0625 0.1875 602

DRIFT ANALYSIS ENGINEERING DEPARTMENT GRAND GULF NUCLEAR STATION Rosemount Range Codes 5 - 8 Gage Pressure Transmitters Outliers &Summary JC-Q1111-09019 Rev. 0 Page 119 of 134 Final Drift Data Final Drift Data Final Drift Data Final Drift Data Final Drift Data Final Drift Data Final Drift Data Final Drift Data Final Drift Raw Data Tag 10 (Pt 1)

(Pt2)

(Pt3)

(Pt4)

(Pt5)

(Pt6)

(Pt7)

(Pt8)

Data (Pt9)

Cal Interval 10#

(0% Up)

(25°4 Up)

(50% Up)

(75% Up)

(100% Up)

(75% On)

(50% On)

(25% On)

(0% On)

(Days)

(%Span)

(%Span)

(%Span)

(%Span)

(%Span)

(%Span)

(%Span)

(%Span)

(%Span) 371 1E22N050 0.1500

-0.1875

-0.1563

-0.3250 0.0875

-0.0125

-0.1500 574 375 1E22N054C 0.0625 0.1250 01875 0.1250 0.1250 0.1250 0.1250 0.1250 0.0625 672 377 1E22N054C 0.1250 0.1875 0.1250 0.1250 0.1875 0.1250 0.1250 0.1250 0.1250 504 381 1E22N054G 00625 0.0625 0.0000 0.0625 0.1250 0.1875 0.1250 0.1250 0.1250 539 383 1E22N054G 0.0000 0.0000 0.0000 0.0000

-0.0625 0.0000 0.0000 0.0625 0.0000 588 387 1E31N085A 0.1250 0.0625 0.0000 0.0000 0.0000 0.0625 0.0000 0.0000 0.1250 589 389 1E31N085A

-0.1250

-0.1875

-0.1875

-0.1250

-0.1875

-0.1875

-0.2500

-0.1875

-0.2500 547 391 1E31N085A

-0.1250 0.0625

-0.0625 0.0000 0.0000 0.0000 0.0000 0.0625 0.0000 551 393 1E31N085A 0.0625

-0.1250

-0.2500

-0.2500

-0.5000

-0.2500

-0.1875 0.0000 0.1250 572 395 1E31N085A

-0.1250

-0.0625 0.0000

-0.1250

-0.1250

-0.1250

-0.0625

-0.0625

-0.3750 529 397 1E31N085A

-0.1250

-0.1250

-0.1875

-0.1250 0.1250

-0.1250

-0.1875

-0.1250 0.1250 517 399 1E31N085A 0.7500 1.0000 1.0000 1.1250 0.9375 1.1875 1.0625 1.0000 0.7500 537 401 1E31N085A

-1.3750

-1.5625

-1.5625

-1.7000

-1.7500

-1.6312

-1.6438

-1.4875

-1.1938 559 405 1E31N085B

-0.3125

-0.4375

-0.5625

-0.6250

-0.5000

-0.5625

-0.6250

-0.5625

-0.3750 581 407 1E31N085B

-0.1250

-0.1250

-0.0625 0.0000

-0.0625 0.0000 0.0000 0.0625

-0.0625 548 409 1E31N085B 0.2500 0.5625 0.6250 0.6250 0.5625 0.4375 0.4375 0.5000 0.2500 551 411 1E31 N085B

-0.0625

-0.3750

-0.2500

-0.3750

-0.5000

-0.3125

-0.2500

-0.1875 0.0625 572 413 1E31N085B OUTLIER OUTLIER OUTLIER OUTLIER OUTLIER OUTLIER OUTLIER OUTLIER OUTLIER 528 415 1E31N085B

-0.1875 0.1250 0.4375 0.6875 1.2500 1.1875 0.6250 0.1875

-0.1250 522 417 1E31N085B 0.6250 0.3750 0.0000

-0.3750

-0.6875

-0.3750 0.0000 0.3750 0.6250 519 419 1E31N085B

-0.6812

-0.6687

-10687

-1.0062

-1.0750

-0.9375

-0.9063

-0.7562

-0.4812 572 423 1E32N05O 0.0000 0.0000

-0.0625

-0.0625 0.0000 0.0000 0.0000 0.0000 0.0000 577 425 1E32N05O

-0.0625 0.1250 0.1250 0.1250 0.1875 0.1250 0.1875 0.1250

-0.0625 549 427 1E32N05O 0.3750 0.0625 0.1250 0.0625 0.1250 0.1875 0.1875 0.2500 0.2500 552 429 1E32N050

-0.3750

-0.1250

-0.1875

-0.0625

-0.1875

-0.1875

-0.3125

-0.3750

-0.2500 571 433 1E32N050 0.0000 0.1250 0.0625 0.0625 0.0625 0.0625 0.0625 0.2500 0.1250 513 435 1E32N050

-2.3750

-2.2500

-2.2500

-2.2500

-2.1250

-2.1875

-2.0625

-2.1875

-2.5000 544 437 1E32N050 1.3750 0.9375 0.1875

-0.6875

-1.5625

-0.7500 0.1875 0.8125 1.4375 159 439 1E32N05O 0.0687 1.0563 1.5625 2.6875 3.5438 2.6875 1.4375 0.9937

-0.1188 602 443 1E32N055 0.0625

-0.0625

-0.0625

-0.0625

-0.1250

-0.0625 0.0000

-0.0625 0.0000 548 445 1E32N055

-0.0625 0.1250 0.1250 0.2500 0.2500 0.1875 0.1875 0.1250 0.0000 642 447 1E32N055 0.0000 0.0000 0.1250 0.0000 0.0000 0.0000 0.0000 0.0625 0.0625 546 449 1E32N055

-0.1250

-0.1875

-0.2500

-0.1875

-0.1875

-0.2500

-0.1250

-0.1875

-0.0625 533 451 1E32N055 0.2500 0.1875 0.0625 0.1875 0.2500 0.2500 0.0625 0.1250 0.2500 519 453 1E32N055 0.3125

-0.0625 0.0625

-0.1875

-0.3750

-0.2500

-0.1250

-0.1250 0.1875 459 455 1E32N055 0.0000

-0.1875

-0.3750

-0.3750

-0.1875

-0.1875

-0.2500

-0.1875 0.0625 548 457 1E32N055 0.1250

-0.0625 0.0625 0.0625 0.0000

-00625 0.1250

-0.0625

-0.1250 546 461 1E32N058

-0.0625

-0.0625

-0.1250

-0.1875

-0.2500

-0.1875

-0.1250

-0.0625

-0.0625 575 463 1E32N058 0.0625 0.0000 0.0000 0.0000 0.0000 0.0000 0.0625 0.0000 0.0625 557 465 1E32N058

-0.0625 0.0625 0.1250 0.1875 0.2500 0.1875 0.0625 0.0625

-0.0625 549 467 1E32N058 0.0000 0.0000 0.0000 0.0000 0.0625 0.0000 0.0000

-0.0625 0.0000 566 471 1E32N058

-0.6250

-0.5000

-0.4375

-0.6250

-0.5625

-0.6250

-0.5625

-0.5000

-0.6250 510

DRIFT ANALYSIS ENGINEERING DEPARTMENT GRAND GULF NUCLEAR STATION Rosemount Range Codes 5 - 8 Gage Pressure Transmitters Outliers &Summary JC-Q1111-09019 Rev. 0 Page 120 of 134 Final Drift Data Final Drift Data Final Drift Data Final Drift Data Final Drift Data Final Drift Data Final Drift Data Final Drift Data Final Drift Raw Data (Pt 1)

(Pt2)

(Pt3)

(Pt4)

(Pt5)

(Pt6)

(Pt7)

(Pt8)

Data (Pt 9)

Cal Interval 10#

Tag 10 (0% Up)

(25% Up)

(50% Up)

(75% Up)

(100% Up)

(75% On)

(50% On)

(25% On)

(0% On)

(Days)

(%Span)

(%Span)

(%Span)

(%Span)

(%Span)

(%Span)

(%Span)

(%Span)

(%Span) 477 1E32N058 0.8750 1.8750 2.7500 3.5625 4.4375 3.5625 2.6250 2.0000 0.9375 601 481 1E32N061 A 0.0625 0.0625 00000 0.0000 0.0000 0.0625 0.0000 0.0625 0.0625 544 483 1E32N061 A

-0.0625

-0.0625 00000 0.0000 0.0000

-0.0625 0.0000

-0.0625

-0.0625 536 485 1E32N061A 0.0625 0.0625 0.0000 0.0000 0.0000 0.0000 0.0000 0.0625 0.0625 598 489 1E32N061A

-0.3125

-0.3125

-0.4375

-0.3750

-<1.3125

-0.3125

-0.4375

-0.3750

-0.3125 533 491 1E32N061A

-0.0625 0.0625 0.3750 0.5000 0.5000 0.3750 0.3750 0.0000

-0.0625 420 493 1E32N061A

-0.2500

-0.1875

-0.3125

-0.6250

-<1.6875

-0.6250

-0.4375

-0.1875

-0.1875 542 495 1E32N061A 0.3125 0.0000 0.0000 0.0000 0.0625 0.0625 0.1250 0.1250 0.1875 548 499 1E32N061E

-0.0625

-0.0625 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000

-0.0625 642 501 1E32N061E

-0.0625

-0.0625

-0.0625 0.0000

-<1.0625 0.0000 0.0000

-0.0625

-0.0625 656 503 1E32N061E 0.0625 0.1250 0.1250 0.1250 0.2500 0.1250 0.1250 0.1250 0.0625 533 507 1E32N061E

-0.4375

-0.5000

-0.5625

-0.5625

-<1.5000

-0.5000

-0.5000

-0.5000

-0.4375 546 509 1E32N061E

-0.3125

-0.3125

-0.4375

-0.5000

-<1.5000

-0.5000

-0.4375

-0.3125

-0.3125 363 511 1E32N061E 0.1250 0.3125 0.4375 0.5000 0.3750 0.3750 0.5000 0.2500 0.2500 601 513 1E32N061E

-0.3125

-0.1875

-0.3750

-0.4375

-<1.2500

-0.2500

-0.3750

-0.3750

-0.2500 548 517 1E32N061J

-0.2500

-0.2500

-0.2500

-0.1875

-<1.1875

-0.1875

-0.1250

-0.1875

-0.1250 543 519 1E32N061J 0.0625 0.1250 0.1875 0.1250 0.0625 0.0625 0.0625 0.0625 0.0000 547 521 1E32N061J

-0.0625

-0.1250

-0.0625

-0.1250

-<1.1875

-0.1875

-0.1875

-0.0625

-0.0625 589 525 1E32N061J

-0.1250 0.0000 0.0000 0.0000 0.0625 0.0625 0.0000 0.0000

-0.1250 507 527 1E32N061J

-0.1250

-0.1875

-0.2500

-0.1250 0.1250

-0.1250

-0.1250

-0.1875

-0.3125 476 529 1E32N061J 0.6250 0.5000 0.5625 0.5625 0.5625 0.5000 0.5625 0.6250 0.7500 544 531 1E32N061J 0.0625 0.0000 0.0625 0.1250 0.1875 0.1875 0.1875 0.1250 0.0625 560 535 1E32N061N 0.0000

-0.0625 0.0000 0.0625

-<1.0625 0.0000 0.0000 0.0000 0.0000 540 537 1E32N061N 0.0000 0.0000 0.0000

-0.0625 0.0000 0.0000

-0.0625 0.0000 0.0000 658 539 1E32N061N 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0625 0.0000 598 543 1E32N061N

-0.5000

-0.5000

-0.5000

-0.3750

-<1.2500

-0.3125

-0.4375

-0.4375

-0.5000 550 545 1E32N061N

-0.1875

-0.2500

-0.1250

-0.0625 0.0000

-0.0625

-0.1250

-0.1250

-0.3125 406 547 1E32N061N 0.4125 0.3625

-0.0813

-0.2938

-<1.2687

-0.2500 0.0062 0.2375 0.3625 541 549 1E32N061N

-0.1000

-0.3000

-0.1687 0.1063 0.0812 0.0625

-0.1312

-0.0500 0.1375 550 553 1E51N035A 0.0000

-0.0625

-0.0625

-00625

-<1.0625 0.0625 0.0625 0.0000

-0.0625 661 555 1E51N035A

-0.0625 0.0000

-0.0625

-0.0625 0.0625 0.0000

-0.1250 0.0000 0.0000 152 557 1E51N035A

-0.0625

-0.0625 0.0000 0.0000

-<1.1250 0.0000 0.0625 0.0000 0.0625 545 561 1E51N035E 0.1875 0.0625 0.0000 0.0000 0.0000 0.0625 0.0000 0.1250 0.1875 664

DRIFT ANALYSIS ENGINEERING DEPARTMENT GRAND GULF NUCLEAR STATION Rosemount Range Codes 5 - 8 Gage Pressure Transmitters Outliers &Summary JC-Q1111-09019 Rev. 0 Page 121 of 134 Final Drift Data Final Drift Data Final Drift Data Final Drift Data Final Drift Data Final Drift Data Final Drift Data Final Drift Data Final Drift Raw Data Ta91D (Pt 1)

(Pt2)

(Pt 3)

(Pt4)

(Pt5)

(Pt6)

(Pt7)

(Pt8)

Data (Pt 9)

Cal Interval 10#

(0% Up)

(25% Up)

(50% Up)

(75% Up)

(100% Up)

(75". On)

(50% On)

(25% On)

(0% On)

(Days)

(%Span)

(%Span)

(%Span)

(%Span)

(".Span)

(%Span)

(%Span)

(%Span)

(%Span) 563 1E51N035E 0.0625 0.0625 0.0625 0.1250 0.0625 0.0625 0.1250 0.0000

-0.0625 631 567 1E51 N055A 0.0625 0.0000 0.0000

-0.0625

-0.1250 0.0000 0.0000 0.0000 0.0625 544 569 1E51 N055A 0.0000 0.0000

-0.0625

-0.1250

-0.0625

-0.1250

-0.1250

-0.0625 0.0000 655 571 1E51 N055A

-0.0625 0.0000 0.0625 0.1250 0.1250 0.1250 0.1250 0.0625 0.0000 591 573 1E51 N055A 0.0625 0.0000 0.0000 0.0000 0.0625 0.0000 0.0000 0.0000 0.0000 532 575 1E51N055A 0.0000

-0.0625

-0.0625

-0.1250

-0.1250

-0.1250

-0.0625

-0.0625 0.0000 666 577 1E51N055A

-0.1250

-0.1875

-0.1250

-0.1250 0.0000

-0.0625

-0.1250

-0.1250

-0.1250 543 579 1E51N055A 0.0625 0.1250 0.0000 0.0000

-0.1250

-0.0625 0.0000 0.0625 0.0625 557 583 1E51N055B

-00625

-0.0625

-0.0625

-0.1250

-0.1250

-0.1250

-0.0625

-0.0625

-0.0625 651 585 1E51N055B 0.0625 0.0625 0.0625 0.0625 0.0000 0.0625 0.0625 0.0625 0.0625 531 587 1E51N055B 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 547 589 1E51 N055B 0.0000 0.0000 0.0000

-0.0625

-0.1250

-0.0625 0.0000 0.0000

-0.0625 646 591 1E51 N055B 0.0000

-0.0625

-0.0625 0.0000 0.0000

-0.0625

-0.0625

-0.0625 0.0000 531 593 1E51N055B 0.0000 0.0000 0.1250 0.0000 0.0625 0.0625 0.1250 0.0625 0.0000 579 595 1E51N055B 0.0000 0.0625

-0.1250

-0.0625

-0.0625

-0.0625

-0.0625 0.0000 0.0625 521 597 1E51N055B

-00625 0.0000 0.0000 0.0000 0.0000 0.0000

-0.0625

-0.0625 0.0000 575 601 1E51N055E

-0.0625

-0.0625

-0.0625

-0.0625

-0.0625

-0.0625

-0.0625 0.0625

-0.0625 603 603 1E51 N055E 0.0000 0.0000

-0.0625 0.0000 0.1250 0.0000 0.0625 0.0000 0.0000 632 605 1E51N055E 0.0625 0.0000 0.0625 0.0000

-0.0625 0.0625 0.0625 0.0625 0.0625 658 607 1E51N055E 0.0625 0.0625 0.0625 0.0625 0.1250 0.0000

-0.0625 0.0000 0.0625 671 609 1E51N055E

-0.1250

-0.1875

-0.2500

-0.1875

-0.3125

-0.1875

-0.1875

-0.1875

-0.1250 665 611 1E51N055E 0.0000 0.0625 0.1250

-0.0625 0.1875 0.0625 0.1250 0.1250 0.0625 544 613 1E51N055E 0.1250 0.0625 0.0625 0.1250

-0.0625 0.0000

-0.0625 0.0000 0.0625 557

DRIFT ANALYSIS ENGINEERING DEPARTMENT GRAND GULF NUCLEAR STATION Rosemount Range Codes 5 - 8 Gage Pressure Transmitters Outliers &Summary JC-Q1111-09019 Rev. 0 Page 122 of 134 Final Drift Data Final Drift Data Final Drift Data Final Drift Data Final Drift Data Final Drift Data Final Drift Data Final Drift Data Final Drift Raw Data Tag 10 (PI 1)

(Pt2)

(PI 3)

(Pt4)

(PI 5)

(Pt6)

(Pt7)

(Pt8)

Data (PI 9)

Cal Interval 101 (0% Up)

(25% Up)

(50% Up)

(750/0 Up)

(100% Up)

(75% On)

(50% On)

(25% On)

(0% On)

(Days)

(OkSpan)

(%Span)

(%Span)

(%Span)

(%Span)

(%Span)

(%Span)

(%Span)

(%Span) 617 1E51N055F 0.0000

-0.0625

-0.1250

-0.0625

-0.0625

-0.0625

-0.0625 0.0000 0.0000 628 619 1E51N055F 0.0000 0.0625 0.1250 0.0625 0.0625 0.0625 0.1250 0.0625 0.0625 604 621 1E51N055F 0.1250 0.0625 0.0000 0.0625 0.0625 0.0625 0.0000 0.0000 0.0625 628 623 1E51N055F

-0.1250

-0.0625 0.0000

-0.0625 0.0000

-0.0625 0.0000 0.0000

-0.0625 532 625 1E51N055F 0.1250 0.0000 0.0000 0.0000

-0.1250 0.0625 0.0625 0.0625 0.0000 580 627 1E51N055F

-0.0625 0.0625 0.0625 00000 0.0625

-0.0625 0.0000 0.0000 0.0625 521 629 1E51N055F 0.0000 0.1250 0.1875 0.2500 0.2500 0.2500 0.1875 0.1250 0.0000 575 Final Drift Data Statistics Summary - After OuUier Removal DataPt.

1 2

3 4

5 6

7 8

9 Mean

-0.0247

-0.0295

-0.0265

-0.0289

-0.0250

-0.0222

-0.0297

-0.0219

-0.0202 Variance 0.0705 0.0957 0.1124 0.1751 0.2498 0.1750 0.1190 0.0910 0.0712 Median 0.00000 0.00000 0.00000 0.00000

-0.03750 0.00000 0.00000 0.00000 0.00000 Std. Dev.

0.2656 0.3094 0.3352 0.4185 0.4998 0.4184 0.3449 0.3017 0.2669 Count 261 269 269 269 268 269 269 269 261 Maximum 1.37500 1.87500 2.75000 3.56250 4.43750 3.56250 2.62500 2.00000 1.43750 Minimum

-2.37500

-2.25000

-2.25000

-2.25000

-2.12500

-2.18750

-2.06250

-2.18750

-2.50000 Ranoe 3.75000 4.12500 5.00000 5.81250 6.56250 5.75000 4.68750 4.18750 3.93750 Sum

-6.45625

-7.93125

-7.13750

-7.78125

-6.70625

-5.97500

-7.98750

-5.88750

-5.27500 Kurtosis 29.372 19.459 27.256 29.910 35.145 29.528 20.676 19.741 33.922 Skewness

-2.217

-1.068 1.082 2.698 3.741 2.793 0.605

-0.616

-2.338 Mean+2*StD 0.5558 0.6483 0.6969 0.8658 1.0245 0.8589 0.7196 0.6252 0.5539 Detected Outliers Sequence 10413 for Calibration Points 1,2,3,4,5,6,7,8 & 9.

Sequence 10439 for Calibration Point 5.

Sequence 10477 for Calibration Points 4,5 & 6.

Calibration point 5 is the worst case, and is chosen as Final Data Set (FDS).

Excluded Outliers (Denoted as such in Final Drift Data columns)

Sequence 10413 for Calibration Points 1,2,3,4,5,6,7,8 & 9.

DRIFT ANALYSIS ENGINEERING DEPARTMENT GRAND GULF NUCLEAR STATION Rosemount Range Codes 5 - 8 Gage Pressure Transmitters Pooling Tests CASE 1: Rosemount 1151 vs 1152 t-Test: Two-Sample Assuming Unequal Variances JC-Q1111-09019 Rev. 0 Page 123 of 134 Mean Variance Observations Hypothesized Mean Differenc df tStat P(T<=t) one-tail t Critical one-tail P(T<=t) two-tail t Critical two-tail 1151

-0.035387324 0.022085875 71 o

182 0.669267205 0.252086573 1.653269024 0.504173146 1.973084036 1152

-0.061927481 0.165255679 131 StDev 0.1486 t Stat < t Critical two-tail?

Sample Means from same pool?

0.4065 TRUE TRUE CASE 2: Rosemount 1151 vs 1153 t-Test: Two-Sample Assuming Unequal Variances 1151 1153 Mean Variance Observations Hypothesized Mean Differenc df tStat P(T<=t) one-tail t Critical one-tail P(T<=t) two-tail t Critical two-tail

-0.035387324 0.022085875 71 o

69

-0.932158958 0.177252345 1.667238549 0.35450469 1.99494539 0.059375 0.661549579 66 StDev 0.1486 t Stat < t Critical two-tail?

Sample Means from same pool?

0.8134 TRUE TRUE CASE 3: Rosemount 1152 vs 1153 t-Test: Two-Sample Assuming Unequal Variances 1152 1153 Mean Variance Observations Hypothesized Mean Differenc df tStat P(T<=t) one-tail t Critical one-tail P(T<=t) two-tail t Critical two-tail

-0.061927481 0.165255679 131o 82

-1.141877292 0.128414253 1.663649185 0.256828506 1.989318521 0.059375 0.661549579 66 StDev 0.4065 t Stat < t Critical two-tail?

Sample Means from same pool?

0.8134 TRUE TRUE

DRIFT ANALYSIS ENGINEERING DEPARTMENT GRAND GULF NUCLEAR STATION Rosemount Range Codes 5 - 8 Gage Pressure Transmitters Pooling Tests CASE 4: TO Ratio less than 1.5 vs 1.5 and greater t-Test: Two-Sample Assuming Unequal Variances JC-Q1111-09019 Rev. 0 Page 124 of 134 Mean Variance Observations Hypothesized Mean Differenc df tStat P(T<=t) one-tail t Critical one-tail P(T<=t) two-tail t Critical two-tail Less than 1.5

-0.005840774 0.337938408 168 o

265 0.933910983 0.175599991 1.650623976 0.351199982 1.968956223 1.5 and Greater

-0.05725 0.101866098 100 StDev 0.5813 t Stat < t Critical two-tail?

Sample Means from same pool?

0.3192 TRUE TRUE

==

Conclusion:==

Two series of pooling tests were conducted to ensure that it is appropriate to combine all of the transmitters for analysis.

Separate groupings by transmitter model number and by differences in turndown ratio are tested. Since all of the transmitter models addressed in this calculation have equal drift specs and are of similar design using the same sigma cell sensing devices, there is no engineering basis to expect that the transmitters would exhibit different drift chararcteristics. The pooling test results show the different models may be combined for analysis. Additional pooling tests were performed to ensure that transmitters with different turndown ratios do not exhibit drift that makes combining these transmitters for analysis inappropriate. The results of these additional pooling tests show that combining the population of transmitters with their various turndown ratios is appropriate.

DRIFT ANALYSIS ENGINEERING DEPARTMENT GRAND GULF NUCLEAR STATION Rosemount Range Codes 5 - 8 Gage Pressure Transmitters D-Prime JC-Q1111-09019 Rev. 0 Page 125 of 134 Orin 5eq.

D' Values No.

Statistic

-2.125 1

283.7

-1.75 2

231.9

-1.5625 3

205.5 Specific 0 Prime Normality Test Methodology from Section 3.7.3 of Reference 4.1.3

-1.375 4

179.4

-1.075 5

139.2 Steps to Perform:

-0.875 6

112.4

1. Paste all final drift data into column 1

-0.875 7

111.6

2. Sort in ascending order.

-0.6875 8

87.0

3. Assign each data point a sequential ascending ID#

-0.6875 9

86.3

4. Calculate ff taking the variance of the drift data adjusted by (Count-1)

-0.6875 10 85.6

-0.625 11 77.2 S2 = (n-1)(Variance (Drift>>

-0.5625 12 68.9

-0.5625 13 68.3 where: n = Count

-0.5625 14 67.8

-0.5 15 59.8

-0.5 16 59.3

5. Calculate S by taking SQRT(~)

-0.5 17 58.8

6. Find each D' statistic in Col C (Formula From Section 3.7.3.1 of Ref. 4.

-0.5 18 58.2

-0.5 19 57.7 D' Stat = {i-[(n+1 )/2]}X;

-0.5 20 57.2

-0.375 21 42.6 where: i = Sequential Number of Drift Value

-0.375 22 42.2 n = Count

-0.375 23 41.8 X; = Drift Value Associated with the Sequential Number

-0.375 24 41.4

-0.375 25 41.1

7. Calculate T by summation of all of the D' Statistics

-0.325 26 35.3

8. Calculate D' and compare to allowed values in Ref. 4.1.7. (Formula Fr<

-0.3125 27 33.6 Section 3.7.3.1 of Ref. 4.1.3.

-0.3125 28 33.3

-0.3125 29 33.0 D' = TIS

-0.3125 30 32.7

-0.3125 31 32.3

-0.3125 32 32.0

-0.3125 33 31.7

-0.3 34 30.2

-0.26875 35 26.7 Computed Values

-0.25625 36 25.2 S2= 66.7

-0.25 37 24.4 S = 8.2

-0.25 38 24.1 T= 6660.0

-0.25 39 23.9 Count (n): 268

-0.25 40 23.6 D' = TIS = 815.6

-0.25 41 23.4

-0.25 42 23.1 Critical D' Values

-0.25 43 22.9 Minimum (PO.02S) :

1219.2

-0.25 44 22.6 Maximum (PO 97S) :

1251.0

-0.25 45 22.4 (Ref. 3.1.7)

-0.25 46 22.1

-0.25 47 21.9 Is PO.02S S D' S PO.97S?:

No

-0.25 48 21.6 Normality Assumption Rejected?:

Yes

-0.25 49 21.4

-0.19375 50 16.4 RESULTS:

-0.1875 51 15.7 Since the calculated D' (815.6) is not within the acceptable range for

-0.1875 52 15.5 268 Data Points (1219.2 to 1251.0), this test rejects the assumption

-0.1875 53 15.3 of normality for this data set.

-0.1875 54 15.1

-0.1875 55 14.9

-0.1875 56 14.7

-0.1875 57 14.5 1.3.)

m Table Interpolation Values Points 260 280 Min 1164 1302 Max 1195.0 1335

DRIFT ANALYSIS ENGINEERING DEPARTMENT GRAND GULF NUCLEAR STATION

-Urift Seq.

D' Values No.

Statistic

-0.1875 58 14.3

-0.1875 59 14.2

-0.1875 60 14.0

-0.1875 61 13.8

-0.1875 62 13.6

-0.16875 63 12.1

-0.1375 64 9.7

-0.125 65 8.7

-0.125 66 8.6

-0.125 67 8.4

-0.125 68 8.3

-0.125 69 8.2

-0.125 70 8.1

-0.125 71 7.9

-0.125 72 7.8

-0.125 73 7.7

-0.125 74 7.6

-0.125 75 7.4

-0.125 76 7.3

-0.125 77 7.2

-0.125 78 7.1

-0.125 79 6.9

-0.125 80 6.8

-0.125 81 6.7

-0.125 82 6.6

-0.125 83 6.4

-0.125 84 6.3

-0.125 85 6.2

-0.125 86 6.1

-0.125 87 5.9

-0.10625 88 4.9

-0.09375 89 4.3

-0.09375 90 4.2

-0.0625 91 2.7

-0.0625 92 2.7

-0.0625 93 2.6

-0.0625 94 2.5

-0.0625 95 2.5

-0.0625 96 2.4

-0.0625 97 2.3

-0.0625 98 2.3

-0.0625 99 2.2

-0.0625 100 2.2

-0.0625 101 2.1

-0.0625 102 2.0

-0.0625 103 2.0

-0.0625 104 1.9

-0.0625 105 1.8

-0.0625 106 1.8

-0.0625 107 1.7

-0.0625 108 1.7

-0.0625 109 1.6

-0.0625 110 1.5

-0.0625 111 1.5

-0.0625 112 1.4

-0.0625 113 1.3

-0.0625 114 1.3

-0.0625 115 1.2

-0.0625 116 1.2

-0.0625 117 1.1

-0.0625 118 1.0 Rosemount Range Codes 5 - 8 Gage Pressure Transmitters D-Prime JC-Q1111-09019 Rev. 0 Page 126 of 134

DRIFT ANALYSIS ENGINEERING DEPARTMENT GRAND GULF NUCLEAR STATION Drift

seq.

D' Values No.

Statistic

-0.0625 119 1.0

-0.0625 120 0.9

-0.0625 121 0.8

-0.0625 122 0.8

-0.0625 123 0.7

-0.0625 124 0.7

-0.0625 125 0.6

-0.0625 126 0.5

-0.0625 127 0.5

-0.0625 128 0.4

-0.0625 129 0.3

-0.0625 130 0.3

-0.0625 131 0.2

-0.0625 132 0.2

-0.05 133 0.1

-0.05 134 0.0

-0.025 135 0.0

-0.0125 136 0.0 0

137 0.0 0

138 0.0 0

139 0.0 0

140 0.0 0

141 0.0 0

142 0.0 0

143 0.0 0

144 0.0 0

145 0.0 0

146 0.0 0

147 0.0 0

148 0.0 0

149 0.0 0

150 0.0 0

151 0.0 0

152 0.0 0

153 0.0 0

154 0.0 0

155 0.0 0

156 0.0 0

157 0.0 0

158 0.0 0

159 0.0 0

160 0.0 0

161 0.0 0

162 0.0 0

163 0.0 0

164 0.0 0

165 0.0 0

166 0.0 0

167 0.0 0

168 0.0 0

169 0.0 0

170 0.0 0

171 0.0 0.0125 172 0.5 0.025 173 1.0 0.04375 174 1.7 0.0625 175 2.5 0.0625 176 2.6 0.0625 177 2.7 0.0625 178 2.7 0.0625 179 2.8 Rosemount Range Codes 5 - 8 Gage Pressure Transmitters D-Prime JC-Q1111-09019 Rev. 0 Page 127 of 134

DRIFT ANALYSIS ENGINEERING DEPARTMENT GRAND GULF NUCLEAR STATION Orin 5eq.

0' Values No.

Statistic 0.0625 180 2.8 0.0625 181 2.9 0.0625 182 3.0 0.0625 183 3.0 0.0625 184 3.1 0.0625 185 3.2 0.0625 186 3.2 0.0625 187 3.3 0.0625 188 3.3 0.0625 189 3.4 0.0625 190 3.5 0.0625 191 3.5 0.0625 192 3.6 0.0625 193 3.7 0.0625 194 3.7 0.0625 195 3.8 0.0625 196 3.8 0.0625 197 3.9 0.0625 198 4.0 0.0625 199 4.0 0.0625 200 4.1 0.0625 201 4.2 0.0625 202 4.2 0.0625 203 4.3 0.0625 204 4.3 0.0625 205 4.4 0.0625 206 4.5 0.0625 207 4.5 0.0625 208 4.6 0.06875 209 5.1 0.08125 210 6.1 0.0875 211 6.7 0.1 212 7.7 0.125 213 9.8 0.125 214 9.9 0.125 215 10.1 0.125 216 10.2 0.125 217 10.3 0.125 218 10.4 0.125 219 10.6 0.125 220 10.7 0.125 221 10.8 0.125 222 10.9 0.125 223 11.1 0.125 224 11.2 0.125 225 11.3 0.125 226 11.4 0.125 227 11.6 0.125 228 11.7 0.125 229 11.8 0.125 230 11.9 0.125 231 12.1 0.125 232 12.2 0.125 233 12.3 0.13125 234 13.1 0.1625 235 16.3 0.175 236 17.8 0.18125 237 18.6 0.1875 238 19.4 0.1875 239 19.6 0.1875 240 19.8 Rosemount Range Codes 5 - 8 Gage Pressure Transmitters D-Prime JC-Q1111-09019 Rev. 0 Page 128 of 134

DRIFT ANALYSIS ENGINEERING DEPARTMENT GRAND GULF NUCLEAR STATION Drln

~eq.

D" Values No.

Statistic 0.1875 241 20.0 0.1875 242 20.2 0.1875 243 20.3 0.1875 244 20.5 0.1875 245 20.7 0.1875 246 20.9 0.25 247 28.1 0.25 248 28.4 0.25 249 28.6 0.25 250 28.9 0.25 251 29.1 0.25 252 29.4 0.25 253 29.6 0.25 254 29.9 0.275 255 33.1 0.375 256 45.6 0.5 257 61.3 0.5625 258 69.5 0.5625 259 70.0 0.5625 260 70.6 0.625 261 79.1 0.9375 262 119.5 1.1875 263 152.6 1.25 264 161.9 1.25 265 163.1 1.875 266 246.6 3.54375 267 469.5 Rosemount Range Codes 5 - 8 Gage Pressure Transmitters D-Prime JC-Q1111-09019 Rev. 0 Page 129 of 134

DRIFT ANALYSIS ENGINEERING DEPARTMENT GRAND GULF NUCLEAR STATION Rosemount Range Codes 5 - 8 Gage Pressure Transmitters Coverage Analysis JC-Q1111-09019 Rev. 0 Page 130 of 134 268 268 Totals Cumulative Nonnal Expected Bin No. StDev Bin Maximums =

Observed Distribution No.

Bin Descriptions (NS)

Mean + (NS*StDev)

Frequency Probability (CP j)

Probability Frequency (Table 18-2 Ref 4.1.4)

(Pnonn = CPj-CPj*1)

(Ei = Pnonn*N) 1 Up to - 2.5 Standard Deviations from Mean

-2.5

-1.2744 4

0.0062 0.0062 1.6616 2

-2.5 to -2.0 Standard Deviations from Mean

-2.0

-1.0245 1

0.0228 0.0166 4.4354 3

-2.0 to -1.5 Standard Deviations from Mean

-1.5

-0.7747 2

0.0668 0.0441 11.8054 4

-1.5 to -1.0 Standard Deviations from Mean

-1.0

-0.5248 7

0.1587 0.0919 24.6158 5

-1.0 to -0.5 Standard Deviations from Mean

-0.5

-0.2749 20 0.3086 0.1499 40.1732 6

-0.5 Standard Deviations from Mean to Mean 0.0

-0.0250 100 0.5000 0.1915 51.3086 7

Mean to +0.5 Standard Deviations from Mean 0.5 0.2249 112 0.6915 0.1915 51.3086 8

+0.5 to +1.0 Standard Deviations from Mean 1.0 0.4747 10 0.8414 0.1499 40.1732 9

+1.0 to +1.5 Standard Deviations from Mean 1.5 0.7246 5

0.9332 0.0919 24.6158 10

+1.5 to +2.0 Standard Deviations from Mean 2.0 0.9745 1

0.9773 0.0441 11.8054 11

+2.0 to +2.5 Standard Deviations from Mean 2.5 1.2244 1

0.9938 0.0166 4.4354 12 More than Mean + 2.5 Standard Deviations More More 5

1.0000 0.0062 1.6616 Observed Observed Percentage for

+/- Sigma Bounds Drift Values Percentages Nonnal Distribution 2.5 (Bins 2-11) 259 96.64%

2 (Bins 3-10) 257 95.90%

95.45%

1.5 (Bins 4-9) 254 94.78%

1 (Bins 5-8) 242 90.30%

68.27%

0.5 (Bins 6-7) 212 79.10%

Mean

-0.0250 Std. Dev.

0.4998 Sample Size 268 Kurtosis 35.145 Methodology for CoYerage Analysis Taken from Section 19 of Reference 4.1.4 and Section 3.7.5 of Reference 4.1.3

1. Order the drift data in ascending order.
2. Obtain mean, standard deviation, sample size, and kurtosis.
3. Establishing bins in 1/2 sigma increments from the mean to 2.5 sigma in both directions, derive the upper bin limits, in units of drift, based on the values of the mean and standard deviation.
4. Obtain expected frequency for a normal distribution in each bin.
5. Manually compute the number of observed drift data points within each bin, and list under observed frequency.
6. Plot the Expected Frequency and the Observed Frequency Data on the Histogram for comparison to each other.
7. Compare the population of data within the +/- 2 standard deviation limits to that of a normal distribution. If necessary, adjust the standard deviation upward to obtain greater than or equal to the percentage contained by a normal distribution.

Results: The data did not pass the D Prime test, so a coverage analysis is necessary. The data is highly peaked in the middle, as is apparent from the Histogram, and from the positive kurtosis value. The observed percent of data within +/- 2 standard deviations is greater than that of a normal distribution. Therefore, the data may be conservatively modeled as a normal distribution without adjustment to the standard deviation.

DRIFT ANALYSIS ENGINEERING DEPARTMENT GRAND GULF NUCLEAR STATION Rosemount Range Codes 5 - 8 Gage Pressure Transmitters Coverage Analysis JC-Q1111-09019 Rev. 0 Page 131 of 134 Histogram of Drift - Grand Gulf Nuclear Station Rosemount Range 5-8 Gage Pressure Transmitters o I I

I 120J I

Ii1IlIllliiObserved

~

Frequency

.... 5:00** Normal Distribution I

80 C

0; 60

sc.

0a.

40 20

-1.2744

-1.0245

-0.7747

-0.5248

-0.2749

-0.0250 0.2249 0.4747 0.7246 0.9745 1.2244 More Drift(%Span)

DRIFT ANALYSIS ENGINEERING DEPARTMENT GRAND GULF NUCLEAR STATION Rosemount Range Codes 5 - 8 Gage Pressure Transmitters Scatter Plot JC-Q1111-09019 Rev. 0 Page 132 of 134 Scatter Plot - Grand Gulf Nuclear Station Rosemount Range 5-8 Gage Pressure Transmitters I --Linear (Drifl) I y = 0.OOO888x - 0.523742 c

co Q.

tn

1

~

0=

'i:

C

  • I.

oA

-1 t

  • +.

+

+

  • I-800 700 600 500 400 300 200

-3.1-'


J 100 Time (Days)

Note: Equation on Scatter Plot is computer generated, based on the associated trend line.

DRIFT ANALYSIS ENGINEERING DEPARTMENT GRAND GULF NUCLEAR STATION Rosemount Range Codes 5 - 8 Gage Pressure Transmitters Binning Analysis Bin Statistics JC-Q1111-09019 Rev. 0 Page 133 of 134 Bin 1 Bin 2 Bin 3 Bin4 Bin 5 Bin 6 Bin 7 Count 2

5 261 Standard Dev.

1.1490 0.3953 0.4949 Mean

-0.7500

-0.0625

-0.0187 Mean Interval 155.50 405.00 567.59 Max Interva 159 459 673 Bin Definition and Selection Bin Hi Valid Limit Bin Population Bins Bins (Days)

Count Percentage Included 1

45 0

0.0%

2 135 0

0.0%

3 230 2

0.7%

4 460 5

1.9%

5 690 261 97.4%

5 6

915 0

0.0%

7 Over 0

0.0%

Total Count:

268 100%

See Section 3.8.3 of Reference 4.1.3 for Binning Analysis Methodology.

JC-Q1111-09019 Rev. 0 Page 134 of 134 Rosemount Range Codes 5 - 8 Gage Pressure Transmitters Analyzed Drift (DA)

DRIFT ANALYSIS ENGINEERING DEPARTMENT GRAND GULF NUCLEAR STATION Drift Bias Determination First, the bias term is evaluated for significance per Section 3.10 of Reference 4.1.3.

Per Outlier Statistical Summary, Time Dependency Count (n)

Absolute Value of Average of FDS Standard Deviation (SFOS) t for Count =268 Data Points Moderate 268 Drift Data Points 0.0250 %Span 0.4998 %Span 1.960 (Ref. 4.1.3, Table 4)

Significant Bias Critical Value (x crit)

[x crit =t

  • S FDS / (n)"0.5]

xcrit =

0.0598 %Span The bias value for this drift data set is not significant, since the Absolute Value of the Average is less than the x crit value.

DA bias (current) = Negligible Random Drift Determination Time Dependency Count (n)

Standard Deviation (s FOS)

Average Bin 5 Observed Interval Maximum Required Cal Interval Tolerance Interval Factor (TIF)

Moderate 268 Drift Data Points 0.4998 %Span 568 Days 915 Days 2.121 (Ref. 4.1.3, Table 1)

[Current Interval Drift =s FDS

  • TIF]

DA random (current) = +/-

1.060 %Span

[Extrap Drift = DA random (current) * (Maximum Required Cal Interval/Average Bin 5 Observed Interval) 1/2]

DA random (extrap) = +/-

1.346 %Span for up to 915 Days

DRIFT ANALYSIS ENGINEERING DEPARTMENT GRAND GULF NUCLEAR STATION DESIGN VERIFICATION COVER PAGE JC-a1111-09019 Rev. 000 Page 1 of 7 o ANO-1 o ANO-2 o IP-2 DIP-3 DJAF DPLP DpNPS OVY 181 GGNS ORBS OW3 ONP Document No.

JC-Q1111-09019 Revision No.: 000 Page 1 01_7_

Title:

Drift Calculation for Rosemount Range Codes 5..8 Gage Pressure Transmitters 181 Quality Related o Augmented Quality Related DV Method:

t8J Design Review o Alternate Calculation o Qualification Testing VERIFICATION COMPLETE AND VERIFICATION REQUIRED DISCIPLINE COMMENTS RESOLVED (DV print, sign, and date)

D Electrical D

Mechanical 181 Instrument and

~/II' /I Control Richard J. Hannigan la/7/--

0 Civil/Structural I

D Nuclear D

Originator:

Aaron Castor I L

~

I

'1/'(11)

PrinVSigniDate After Comments Have Been R;5Oilied

DRIFT ANALYSIS ENGINEERING DEPARTMENT GRAND GULF NUCLEAR STATION DESIGN VERIFICATION CHECKLIST JC-Q1111-Q9019 Rev. 000 Page 2 of 7 SHEET 1 oF3 IDENTIFICATION:

DISCIPLINE:

Document

Title:

Drift Calculation for Rosemount Range Codes 5-8 Gage DCiviVStructural Pressure Transmitters oElectrical Doc. No.: JC-Q1111-09019 Rev. 000 QA Cat. 1 1811 & C oMechanical Verifier:

Richard J. Hannigan L~/~

l61"/1J oNuclear Print

~Sign Date DOther Manager authorization for supervisor performing Verification.

181 N/A Print Sign Date METHOD OF VERIFICATION:

Design Review IZJ Alternate Calculations 0 Qualification Test 0 The following basic questions are addressed as applicable, during the performance of any design verification. These questions are based on the requirements of ANSI N45.2.11 -1974.

NOTE The reviewer can use the "Comments/Continuation sheef at the end for entering any comment/resolution along with the appropriate question number. Additional items with new question numbers can also be entered.

1.

Design Inputs - Were the inputs correctly selected and incorporated into the design?

(Design inputs include design bases, plant operational conditions, performance requirements, regulatory requirements and commitments, codes. standards, field data, etc.

All information used as design inputs should have been reviewed and approved by the responsible design organization, as applicable.

All inputs need to be retrievable or excerpts of documents used should be attached.

See site specific design input procedures for guidance in identifying inputs.)

Yes 181 No 0 N/A 0 2.

Assumptions - Are assumptions necessary to perform the design activity adequately described and reasonable? Where necessary, are assumptions identified for subsequent re-verification when the detailed activities are completed? Are the latest applicable revisions of design documents utilized?

Yes 181 No 0 N/A 0 3.

Quality Assurance - Are the appropriate quality and quality assurance requirements specified?

Yes 181 No 0 N/A 0

DRIFT ANALYSIS ENGINEERING DEPARTMENT GRAND GULF NUCLEAR STATION DESIGN VERIFICATION CHECKLIST JC*Q1111*09019 Rev. 000 Page 3 of 7 SHEET 2 OF 3 4.

Codes, Standards and Regulatory Requirements - Are the applicable codes, standards and regulatory requirements, including issue and addenda properly identified and are their requirements for design met?

Yes 181 No 0 N/A 0 5.

Construction and Operating Experience - Have applicable construction and operating experience been considered?

Yes 0 No 0 N/A 181 6.

Interfaces - Have the design interface requirements been satisfied and documented?

Yes 181 No 0 N/A 0 7.

Methods - Was an appropriate design or analytical (for calculations) method used?

Yes 181 No 0 N/A 0 8.

Design Outputs - Is the output reasonable compared to the inputs?

Yes 181 No 0 N/A 0 9.

Parts, Equipment and Processes - Are the specified parts, equipment, and processes suitable for the required application?

Yes 0 No 0 N/A 181 10.

Materials Compatibility - Are the specified materials compatible with each other and the design environmental conditions to which the material will be exposed?

Yes 0 No 0 N/A 181 11.

Maintenance requirements - Have adequate maintenance features and requirements been specified?

Yes D*

No 0 N/A 181 12.

Accessibility for Maintenance - Are accessibility and other design provisions adequate for performance of needed maintenance and repair?

Yes 0 No 0 N/A 181 13.

Accessibility for In-service Inspection - Has adequate accessibility been provided to perform the in-service inspection expected to be required during the plant life?

Yes 0 No 0 N/A 181 14.

Radiation Exposure - Has the design properly considered radiation exposure to the public and plant personnel?

Yes 0 No 0 N/A 181 15.

Acceptance Criteria - Are the acceptance criteria incorporated in the design documents sufficient to allow verification that design requirements have been satisfactorily accomplished?

Yes 0 No 0 N/A 181 16.

Test Requirements - Have adequate pre-operational and subsequent periodic test requirements been appropriately specified?

Yes 0 No 0 N/A 181

DRIFT ANALYSIS ENGINEERING DEPARTMENT GRAND GULF NUCLEAR STATION DESIGN VERIFICATION CHECKLIST JC-Q1111-09019 Rev. 000 Page 4 of 7 SHEET 3 OF 3 17.

Handling, Storage, Cleaning and Shipping - Are adequate handling, storage, cleaning and shipping requirements specified?

Yes 0 No 0 N/A 181 18.

Identification Requirements - Are adequate identification requirements specified?

Yes 0 No 0 N/A 181 19.

Records and Documentation - Are requirements for record preparation, review, approval, retention, etc., adequately specified? Are all documents prepared in a clear legible manner suitable for microfilming and/or other documentation storage method? Have all impacted documents been identified for update as necessary?

Yes 181 No 0 N/A 0 20.

Software Quality Assurance-ENN sites: For a calculation that utilized software applications (e.g., GOTHIC, SYMCORD), was it properly verified and validated in accordance with EN-IT-104 or previous site SQA Program?

ENS sites: This is an EN-IT-104 task. However, per ENS-DC-126, for exempt software, was it verified in the calculation?

Yes 0 No 0 N/A 181 21.

Has adverse impact on peripheral components and systems, outside the boundary of the document being verified, been considered?

Yes 0 No 0 N/A 181

DRIFT ANALYSIS ENGINEERING DEPARTMENT GRAND GULF NUCLEAR STATION DESIGN VERIFICATION COMMENT SHEET Comments / Continuation Sheet JC*Q1111*09019 Rev. 000 Page 5 of 7 SHEET 1 OF 1 Question Comments Resolution Initial/Date NONE

DRIFT ANALYSIS ENGINEERING DEPARTMENT GRAND GULF NUCLEAR STATION JC*Q1111*09019 Rev. 000 Page 6 of 7 During the independent review of calculation JC-Q1111-09019, alternate application Lotus 1-2-3 was used to validate the results generated by MS Excel in the calculation. The reviewer independently generated the JC-Q1111-09019 results. In the table below the results of the validation for the JC-Q1111-09019 values and the values produced by Lotus 1-2-3 are illustrated for Data Point 5 - the point with the greatest magnitude IMeanl + 2 x Std Dev value. The Final Data Set is derived from the Initial Data Set after removing the greatest of the three outliers. The results from Lotus 1-2-3 validated the calculation JC-Q1111-09019 results generated by MS Excel.

Minor differences in the values between the MS Excel generated results and the Lotus 1-2-3 generated results were reviewed and can be attributed to rounding and conversion between applications. Below is a partial listing of some of the values from JC-Q1111-09019 that were validated:

Parameter JC*Q1111*09019 value Validation value Validation Valid?

application Mean

-0.0250

-0.0250 Lotus 1-2-3 Yes Variance 0.2498 0.2498 Lotus 1-2-3 Yes Median

-0.03750

-0.0375 Lotus 1-2-3 Yes Standard Deviation 0.4998 0.4998 Lotus 1-2-3 Yes Count 268 268 Lotus 1-2-3 Yes Max 4.43750 4.4375 Lotus 1-2-3 Yes Min

-2.12500

-2.1250 Lotus 1-2-3 Yes Range 6.56250 6.56250 Lotus 1-2-3 Yes Sum

-6.70625

-6.7062 Lotus 1-2-3 Yes Kurtosis 35.145 35.145 Lotus 1-2-3 Yes Skewness 3.741 3.7407 Lotus 1-2-3 Yes Outliers Sequ ID 413 (all pts),

Sequ ID 413 (all pts),

Lotus 1-2-3 Yes Sequ ID 439 (pt 5), Sequ Sequ ID 439 (pt 5), Sequ ID 477 (pts 4 - 6)

ID 477 (pts 4 - 6) identified as outliers.

identified as outliers.

Sequ ID 413 (all pts)

Sequ ID 413 (all pts) removed.

removed.

Drift scatter plot N/A Visual inspection shows Lotus 1-2-3 Yes with trend line agreement between the scatter plots and trend lines Drift scatter plot y =8.88E-04x y =8.88E-04x Lotus 1-2-3 Yes trend line

-5.23742E-01

-5.24E-01 D Prime 815.6 (rejects assumption 815.6 (rejects assumption Lotus 1-2-3 Yes of normalitv) of normalitv)

Histogram N/A Visual inspection shows Lotus 1-2-3 Yes agreement between the histoQrams

DRIFT ANALYSIS ENGINEERING DEPARTMENT GRAND GULF NUCLEAR STATION JC-Q1111-09019 Rev. 000 Page 7 of 7 Parameter JC*Q1111*09019 value Validation value Validation Valid?

application Data within 2.5 259 259 Lotus 1-2-3 Yes Standard Deviations Data within 2.0 257 257 Lotus 1-2-3 Yes Standard Deviations Data within 1.5 254 254 Lotus 1-2-3 Yes Standard Deviations Data within 1.0 242 242 Lotus 1-2-3 Yes Standard Deviations Data within 0.5 212 212 Lotus 1-2-3 Yes Standard Deviations Bin 3 count 2

2 Lotus 1-2-3 Yes Bin 3 drift 1.1490 1.1490 Lotus 1-2-3 Yes Standard Deviation Bin 3 drift mean

-0.7500

-0.7500 Lotus 1-2-3 Yes Bin 3 interval mean 155.50 155.5000 Lotus 1-2-3 No Bin 3 interval maximum 159 159 Lotus 1-2-3 Yes Bin 4 count 5

5 Lotus 1-2-3 Yes Bin 4 drift 0.3953 0.3953 Lotus 1-2-3 Yes Standard Deviation Bin 4 drift mean

-0.0625

-0.0625 Lotus 1-2-3 Yes Bin 4 interval mean 405.00 405.0000 Lotus 1-2-3 Yes Bin 4 interval maximum 459 459 Lotus 1-2-3 Yes Bin 5 count 261 261 Lotus 1-2-3 Yes Bin 5 drift 0.4949 0.4949 Lotus 1-2-3 Yes Standard Deviation Bin 5 drift mean

-0.0187

-0.0187 Lotus 1-2-3 Yes Bin 5 interval mean 567.59 567.59 Lotus 1-2-3 Yes Bin 5 interval maximum 673 673 Lotus 1-2-3 Yes Other values, including those based on the above parameters, were checked using hand calculations.

GNRO-2013/00001 Page 30 of 01-5-06-12

GRAND GULF NUCLEAR STATION

Title:

GGNS Surveillance Program No.:

01-S-06-12 ADMINISTRATIVE PROCEDURE Revision:

111 Page:

30 6.8.2 6.8.3 (Cont. )

d.

The following conditions require generation of a Condition Report in accordance with Corporate Procedure EN-LI-I02, Corrective Action Process.

As Found Data Unacceptable As Left Data Unacceptable Tech Spec Data Unacceptable 1ST Acceptance Criteria Unacceptable, in the Alert Range or in the Required Action Range

  • Valve Data Unacceptable or noted as Evaluation Required Other information, such as observations or any unexpected or unusual conditions may be documented in a Condition Report at the discretion of the department performing the Surveillance
activity, based on the requirements and guidelines provided in EN-LI-102.

The test performer should use the following guidelines in completing Section 3.0 of the Data Package Cover Sheet:

Each Surveillance Procedure Data Package Cover Sheet is modified during procedure preparation in order to match the specific procedure; thus, some items discussed here are not applicable to some procedure data packages.

a.

Procedure Completion - Entire vs. Partial (1)

If all steps associated with the data package were performed, check "entire procedure completed".

(2)

If, for any reason, all steps are not completed, check Itpartial procedure completed".

Reason may include:

(a)

Computer out of service does not allow checking non-essential computer points.

(b)

Surveillance procedure is used as a retest for one item and all steps do not need to be performed.

(c)

Equipment is inoperable making completion of test impossible.

(d)

Plant SCRAM occurs during test.

(e)

Test performance is administratively stopped.

b.

As Found Data Acceptability

{I}

If any of the recorded "As Found" data does not fall within the allowable min/max limits as specified in the procedure, check "Unacceptable."

J:\\ADM_SRVS\\TECH_PUB\\REVISION\\1\\lS0612.DOC GNRO-2013/00001 Page 63 of EN-OP-104

NUCLEAR QUALITY RELATED EN-OP-104 I REV. 6

~~Entergy MANAGEMENT MANUAL INFORMATIONAL USE PAGE 63 OF 95 Operability Determination Process 5.9 Cont.

[21]

Missed or Deficient Surveillances [ANO OCNA119404]

(a)

If a Plant's TSs provide different guidance than the guidance in this subsection related to missed or deficient surveillances, the Plant's TSs guidance applies instead.

(b)

Technical Specification related equipment or systems are declared INOPERABLE upon discovery of a missed or deficient surveillance test, unless the TS states otherwise. At the time of discovery of the missed or deficient test, the action statement of the appropriate LCO/AOT is applicable; however, if actions are required to be performed within 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> or less, the 24-hour allowance provided by Technical Specification may be entered. If Reasonable Expectation of Operability does not exist, immediately declare the equipment or system INOPERABLE. If, during the testing, the surveillance results in inoperability, then the appropriate LCO/AOT action statement requirements must be applied.

(c)

If it is discovered that a Surveillance was not performed within its specified Frequency, then compliance with the requirement to declare the LCO/AOT not met may be delayed from the time of discovery up to 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br />, or up to the limit of the specified Frequency, whichever is greater. This delay period is permitted to allow performance of the Surveillance. A PRA evaluation shall be performed per site-specific procedures for any surveillance delayed greater than 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> and the risk impact shall be managed.

(d)

If the Surveillance is not performed within the delay period, the LCO/AOT must immediately be declared not met, and the applicable LCO Condition(s) must be entered.

(e)

When the Surveillance is performed within the delay period and the Surveillance is not met, the LCO/AOT must immediately be declared not met, and the applicable Condition(s) must be entered.