Text
ENT00331A Submitted: March 29, 2012 United States Nuclear Regulatory Commission Official Hearing Exhibit In the Matter of:
Entergy Nuclear Operations, Inc.
(Indian Point Nuclear Generating Units 2 and 3)
ASLBP #: 07-858-03-LR-BD01 Docket #: 05000247 l 05000286 Exhibit #:
Identified:
Admitted:
Withdrawn:
Rejected:
Stricken:
Other:
ENT00331A-00-BD01 10/15/2012 10/15/2012 c:..\\,.~p..R REGlI~;.
l~'~
0
~
J"
~
~
....... 1-0'
?
~
- il Onc EUgcw:ul.'r nnw mwood MassachusettS 02062 78 1-27H-J7f)()
FAX '1 -278-5701 WWW.J.!1n.cum GZA GeoEnVlIonmental, Inc.
January 7, 2008 File No. 41.0017869_10 Mr. Robert Evers Enercon Services, Inc.
Indian Point Energy Center 450 Broadway Buchanan, NY 10511-0308 J:;trSinccrs mId SGlelllists
Subject:
Hydrogeologic Site Investigation Report Indian Point Energy Center Buchanan, New York
Dear Mr. Evers:
GZA GeoEnvironmental, Inc. (GZA) is pleased to provide the attached Hydrogeologic Site Investigation Report for the Indian Point Energy Center. The report provides a summary of the investigative method, findings/conclusions and recommendations for work conducted from September 2005 through the end of September 2007.
If you have any questions, please contact either David or Matt.
GZA appreciates the opportunity to provide continued support to Enercon Services and Entergy.
Sincerely, GZA GEOENVIRONMENTAL, INC.
~Mt\\ ~, \\J1J\\1(1ow j~
David M. Winslow, Ph.D., P.G.
Associate Principal I
.::~
- J..,~~~~
Mi hael Powers, P.
S r Principal An F.qual Oppnnullhy f.mplo cr l\\ilFNIH Matthew J. Barvenik, LSP Senior Principal
TABLE OF CONTENTS EXECUTIVE
SUMMARY
.............................................................. viii ti\\)
1.0 1.1
1.2 INTRODUCTION
..................................................................... 1 PURPOSE.....*..............................................*............................................................*................... 1 BACKGROUND....*.......*..................*...*..............*...*..........**......*..*.......*.......*...................*...*...... 2 2.0 SCOPE OF SERViCES.................**......*..............................*.... 6 2.1 PHASE I........................................................................................................................................ 6 2.2 PHASE II...................................................................................................................................... 1 2.J PHASE III..................................................................................................................................... 8 3.0 CONCEPTUAL HYDROGEOLOGIC MODEL.......................... 9 3.1 HYDROGEOLOGIC SETTING.............................................................................................. 10 3.2 GENERAL GROUNDWATER FLOW PATTERNS............................................................. 10 3.3 IDENTIFIED CONTAMINANT SOURCES........................................................................... II 3.4 CONTAMINANTS OF INTEREST......................................................................................... 11 3.5 IOENTIFIED RECEPTORS................................ ".....,,,........................................................... 12 4.0 FIELD INVESTIGATIONS.................................................... 15 4.1 GEOLOGIC RECONNAiSSANCE.......................................................................................... 16 4.2 TEST DRILLING...... "........................................... ".............................................. " *................. 17 4,2. 1 Bedrock Borings..................................................................................................................... 19 4.2.2 Overburden Borings........................................,.........,............................................................. 21 4.2.3 Borehole Development............................................................................................................ 22 4.2.4 Borehole Geophysical Anaiysis............................................................................................... 22 4.3 WELL INSTALLATIONS........................................................................................................ 23 4.3. 1 Bedrock Wells......................................................................................................................... 23 4.). 1.1 Open Rock Wells................................................................................................................ 23 4.3.1,2 Waterloo Multi*Level Completion Wells........................................................................... 24 4.3, I,3 Nested Wells.................................................................................................
............. 26 4.3.2 Overburden Wells..........................................................................,......................................... 26 4.3.3 Wellhead Completion................,............................................................................................. 27 4.3.4 Well Nomenclature.................................................................................................................. 27 4.3,5 Wellhead Elevation Surveying...........................,.................................................................... 28
4.4 4.4.1 4.4.2 4.4.3 4.4.4 4.5 HY D RA U L IC T EST I NG. "".. ".. ".".. ".. ".. ".".. "" "" "" """"""" """"""""" """""" """"""""" 28 Short Duration Specific Capacity Tests................................................................................... 28 Rising Head Hydraulic Conductivity Tests............................................................................. 29 Bedrock Packer Extraction Hydraulic Conductivity Testing................
............................. 30 Pumping Test............ "............................................................................................................ 33 WATER SAMPLlNG................................................................................................................ 35 4.5. 1 4.5.1.1 4.5.1.2 4.5.1.3 4.5.1.4 4.5.2 On-Site Groundwater Sampling.............................................................................................. 35 Purging..............................................
.................................................................... 36 Low Flow Sampling............................................................................................................ 36 Waterloo Low Flow Sarnpting............................................................................................ 37 Discrete Interval Packer Sampling...................................................................................... 37 On-Site Surface Water Sampling....
........................................................................ 37 4.5.3 4.5.4 Off-Site Groundwater Sampling.............................................................................................. 38 OtT-Site Surface Water Sampling............................................................................................ 38 4.6 PI EZOMETRIC LEVELS AND PRESSURE T RANSDUCER DATA................................. 39 4,6. \\
Transducer Types and Data RetrievaL..................................................................................39 4.6.2 Data Availability and Preservation..........................................................................................40 4.7 4.7.1 4.7.2 4.7.3 4.7.4 4.8 5.1 5.1.1 5.2 5.3 6.1 6.2 6.3 6.4 6.4. 1 6.4.2 6.4.3 6.4.4 6.4.5 6.4.6 6.4.7 6.4.8 TRACER TESTING.............................................................................,.................................... 40 Injection Well Construction....................................................................................................41 Background Sampling...........................................................................................................4 1 Sampling Stations............
.....41 Analysis Schedule.................................................................................................................. 42 ADDITIONAL GEOPHYSICAL TESTING TO EVALUATE FLOW PATHS..................42 LABORATORY TESTING..................................................... 44 RADfOLOGICAL...........................................................,.......................................................... 44 Hydrogeologic Site Investigation Analytical Data........
.................................................... 44 ORGANIC TRACER................................................................................................................. 46 WATER QUALITY PARAM ETERS....................................................................................... 46 HYD ROGEOLOGIC SETTING.............................................. 47 REGIONAL SETTING.............................................................................................................. 47 GROUNDWATER RECHARGE............................................................................................. 47 GROUNDWATER DISCHARGE............................................................................................48 GEOLOGY................................................................................................................................. 49 Overburden Geology.................................................................................
.........49 Bedrock Geology.........................................................................................
....... 50 Groundwater in Bedrock...............................................................
....... 52 Regional Scale Geostruc{ure.........................................................................
....... 53 Site Scale Geostructure......................................................................
..................... 53 Borehole Scale Geostructure................................................................................................ 53 Geologic Faults...............................
.................................................................................. 55 Bedrock Structure Visualization......
......................................................................... 56 11
6.4.9 Bedrock Surface Elevations and Preferential Groundwater Flow Pathways............................ 57 6.5 AQUIFER PROPERTIES..*.......**..*...............*.*......*....**..*..............*...*.................*...*...*........... 58 6.5.1 Hydraulic Conductivity......
............................................................... 59 6.5.2 Effective Porosity......................
................................................................................ 61 6.6 TIDAL INFLUENCES............................................................................................................... 62 6.6.1 Groundwater Levels................................................................................................................. 63 6.6.2 Groundwater Temperature....................................................................................................... 65 6.6.2.1 Monitoring Well MW-38................................................................................................... 66 6.6.2.2 Monitoring Well MW-48..................................................
.................................... 67 6.6.3 Aqueous Geochemisrry............................................................................................................ 70 6.6.3.1 Sampling........................................................................................................................... 71 6.6.3.2 Water Quality Evaluation................................................................................................... 71 6.7 GROUNDWATER FLOW PA TTERNS.......................................,......,......,............................ 72 6.7.1 Groundwater Flow Direction............................................................................................... 73 6.7.2 Groundwater Flow Rates......................................................................................................... 74 6.7.2.1 Seepage Velocities..............
..................................................................................... 74 6.7.2.2 Groundwater Flux........
........................................................................................ 75 GROUNDWATER TRACER TEST RESULTS......................*.. 79 7.1 TRACER INJECTION............................ "................................................................................ 79 7.2 TRACER CONCENTRA TION MEASUREMENTS............................................................. 81 7.3 SPATIAL DISTRIBUTION AND EXTENT OF FLUORESCEIN IN GROUNDWATER81 7.4 TEMPORAL DISTRIBUTION OF FLUORESCEIN IN GROUNDWATER...................... 84 7.5 FLUORESCEIN IN DRAINS, SUMPS AND THE DISCHARGE CANAL......................... 87 7.6 MAJOR FINDINGS...*....*..*...*..*.*.*........**.**...*......*..**..*...*...........*.............*...**..*..*...*...*..*...*..... 88 CONTAMINANT SOURCES AND RELEASE MECHANISMS. 89 8.1 UNIT 2 SOURCE AREA........................................................................................................... 90 8.1.1 8.1.2 Direct Tritium Sources............................................................................
................... 92 Indirect Storage Sources of Tritium...
................................................................................ 97 8.2 UNIT I SOURCE AREA....*............*.......*......*......*.*............*...*...........*..*.....................*......... 101 9.0 GROUNDWATER CONTAMINATION FATE AND TRANSPORT................................................................................ 114 9.1 AREAL EXTENT OF GROUNDWATER CONTAMINATION........................................ 11 5 9.2 DEPTH OF GROUNDWATER CONT AMlNA T10N.......................................................... 115 9.3 UNIT 2 TRITIUM PLUME BEHAViOR.............................................................................. 115 9.3.1 Short Tenn Tritium Fluctuations........................................................................................... 118 9.3.2 Long Tenn Variations in Tritium Concentrations................................................................. 120 III
~
9.4 UNIT I STRONTIUM PLUME BEHAVIOR..,............,,,..,,,,,,,,.,,,,,,....,,..,.............,........,,... 122 9.4.1 Short Term Strontium Concentrations................................................................................... 124 9.4.2 Long Tenn Variations in Strontium Groundwater Variations............................................... 124 10.0 FINDINGS AND CONCLUSIONS......................................... 127 10.1 NATURE AND EXTENT OF CONTAMINANT MIGRATION......................................... 127 10.2 SOURCES OF CONT AMIN A TION........................................ __............................... ________..... 128 10.3 GROUNDWATER CONTAMINANT TRANSPORT.**..............**.*..............*....*.....*...*....... 130 10.4 GROUNDWATER MASS FLUX CALCULATIONS.......................................................... 131 10.5 G ROUNDW A TE R M ON ITORIN G __........ ".. "..... ".".................................................. ".. "..... 132 10.6 COM PLETE NESS............. ".......... ".... "...... "... "........... "................ "...................................... 132 11.0 RECOMMENDATIONS........................................................ 134 TABLES TABLE 4.1 TABLE 4.2 TABLE 4.3 TABLE 4.4 TABLE 4.5 TABLE 5.1 TABLE 6.1 FIGURES FIGURE 1.1 FIGURE 1.2 FIGURE 1.3 FIGURE 3.1 FIGURE 3.2 FIGURE 3.3 FIGURE 3.4 FIGURE 4.1 FIGURE 4.2 FIGURE 4.3 FIGURE 4.4 FIGURE 6.1 FIGURE 6.2
SUMMARY
OF WELL LOCATIONS AND INSTALLATION DEPTHS WELL NOMENCLATURE WELL HEAD ELEVATION CHANGES HYDRAULIC CONDUCTIVITY ESTIMATES TRANSDUCER lNFORMA TION GROUNDWATER ANALYTICAL DATA GROUNDWATER ELEVATIONS SITE LOCUS PLAN SITE PLAN EXPLORATION LOCATION AND DATA
SUMMARY
PLAN WATERSHED BOUNDARY MAP REGIONAL TOPOGRAPHY REGIONAL GROUNDWATER FLOW CONTAMINANT SOURCE MAP PNEUMATIC SLUG TEST MANIFOLD SCHEMA TIC PACKER TEST ASSEMBLAGE SCHEMATIC USGS WELL LOCATION MAP RESERVOIR LOCATION MAP GROUNDWATER/SURFACE WATER INTERFACE SITE AREA USGS GEOLOGIC MAP IV
FIGURE 6.3 FIGURE 6.4 FIGURE 6.5 FIGURE 6.6 FIGURE 6.7 FIGURE 6.8 FIGURE 6.9 FIGURE 6.10 FIGURE 6.11 FIGURE 6.12 FIGURE 6.13 FIGURE 6.14 FIGURE 6.15 FIGURE 6.16 FIGURE 6.17 FIGURE 6.18 FIGURE 6.19 FIGURE 6.20 FIGURE 7.1 FIGURE 7.2 FIGURE 7.3 FIGURE 8.1 FIGURE 8.2 FIGURE 8.3 FlGURE9.1 FIGURE 9.2 FIGURE 9.3 FIGURE 9.4 APPENDICES APPENDIX A APPENDIX B APPENDIX C SITE UNCONSOLLDATED GEOLOGIC MAP SITE GEOLOGICAL MAP REGIONAL LINEAMENT MAP SITE LINEAMENT MAP POLAR PROJECTIONS PROFILE LOCATIONS FRACTURE PROFILE PROJECTIONS TRANSMISSlVE FRACTURE LOCATIONS LOW TRANSMJSSIVITY TRANSMISSIVE FRACTURE LOCATIONS MODERATE TRANSMJSSIVITY TRANSMISSIVE FRACTURE LOCATIONS HIGH TRANSMISSIVITY FRACTURE STRJKE ORIENTATION AT ELEVATION 10 FRACTURE STRIKE ORIENTATION AT ELEVATION -100 AMBIENT AND PUMPING GROUNDWATER CONTOURS WITH TIDAL RESPONSE AND TEMPERATURE STIFF DIAGRAMS OF MW-38, MW-48, HUDSON RJVER, AND DISCHARGE CANAL SHALLOW GROUNDWATER CONTOURS UNITS I AND 2 HYDROLOGIC CROSS SECTIONS A-A' AND B-B' SHALLOW GROUNDWATER CONTOUR MAP WITH STREAMTUBES DEEP GROUNDWATER CONTOUR MAP WITH STREAMTUBES SCHEMATIC OF INJECTION WELL LOCATION AND DESIGN BOUNDING TRACER (FLUORESCEIN) CONCENTRATION ISOPLETHS I IN GROUNDWATER CURRENT TRACER (FLUORESCEIN) CONCENTRATION ISOPLETHS I IN GROUNDWATER BOUNDING UNIT 2 ACTIVITY ISOPLETHS BOUNDING UNIT I ACTIVITY ISOPLETHS BOUNDING CESIUM (Cs), COBALT (Co) AND NlCKEL (Nil ACTlVlTY IN GROUNDWATER UNIT 2 TRITIUM PLUME CROSS SECTION A-A' UNIT I STRONTIUM PLUME CROSS SECTION B-B' CURRENT UNIT 2 ACTIVITY ISOPLETHS CURRENT UNIT I ACTIVITY ISOPLETHS LIMITATIONS BORJNG LOGS GEOPHYSICAL BOREHOLE LOGS v
APPEND[)( D APPEND[)( E APPEND[)( F APPEND[)( G APPENDIX H APPENDIX I APPENDIX J APPENDIXK APPENDIXL APPENDIX M APPENDIXN APPENDIX 0 APPENDIX P APPENDIXQ APPENDIX R APPENDIX S WELL CONSTRUCTION LOGS SURVEY RESULTS SPECIFIC CAPACITY TEST LOGS HYDRAULIC CONDUCTIVITY CALCULATIONS SLUG TEST FIELD LOGS PACKER TEST FIELD LOGS LOW FLOW SAMPLING LOGS CD WITH PIEZOMETRIC DATA HYDROGRAPHS TRANSDUCER INSTALLATION LOGS ORGANIC TRACER TEST RESULTS SURFACE GEOPHYSICAL SURVEY REPORTS OUL PROCEDURES AND CRITERIA FRACTURE SET DATABASE GROUNDWATER CONTOUR MAPS RAINFALL MODEL FLUX CALCULA nONS vi
ADT AGS ALARA AREOR ATV CSS CSB CSM EPA EVS GA GPR GZA
!P IPI*CSB IPI-FHB IP I*SFDS IPI*SFPS IPI*CB
!P2*FSB IP2*PAB 1P2*SFP IP2*TB IP2*TY IP2*VC K
NGVD29 NYSDEC MGM MNA MW NEI NCD NRC OCA OTV RWST RQD SFDS SFP SOP SSC TGB TY USGS VC ACRONYMS Aquifer Drilling and Testing Advanced Geological Services As Low As Reasonably Ach ievable Annual Radiological Environmental Operating Report Acoustical Televiewer Containment Spray Sump Chemical Systems Building Conceptual Site Model Environmental Protection Agency Environmental Visualization Software Geophysical Applications, Inc.
Ground Penetrating Radar aZA GcoEnvironmental, Inc.
indian Point Indian Point Unit I Chemical Systems Building lndian Point Unit I Fuel Handling Building Indian Point Unit I Sphere Foundation Drain Sump Indian Point Unit I Spent Fuel Pool Indian Point Unit I Containment Building Indian Point Unit 2 Fuel Storage Building Indian Point Unit 2 Primary Auxiliary Building Indian Point Unit 2 Spent Fuel PoolS Indian Point Unit 2 Turbine Generator Building Indian Point Unit 2 Transfonner Yard Indian Point Unit 2 Vapor Containment Hydraulic Conductivity National Geodetic Vertical Datum of 1929 New York State Department of Environmental Conservation Million Gallons per Minute Monitored Natural Attenuation Monitoring Well Nuclear Energy Institute North Curtain Drain Nuclear Regulatory Commission Owner Controlled Area Optical Televiewer Reactor Water Storage Tank Rock Qual ity Designation Sphere Foundation Drain Sump Spent Fuel Pool Standard Operating Procedure Structures, Systems and Components Turbine Generator Building Transtonner Yard United States Geological Survey Vapor Containment VII
EXECUTIVE
SUMMARY
This report presents the results of a two-year comprehensive hydrogeologic site investigation of the Indian Point Energy Center (Site) conducted by GZA GeoEnvironmental. Inc. (OZA). The study was initiated in response to an apparent release of Tritium to the subsurface. initially discovered in August of 2005 during Unit 2 construction activities associated with the Independent Spent Fuel Storage InstalJation Project. These investigations were subsequently expanded to include areas of the Site where credible-potential sources of leakage might exist. and encompassed all three reactor units. Ultimately, these investigations traced the contamination back to two separate structures, tl,e Unit 2 and Unit I Spent Fuel Pools (SFPs). The two commingled plumes. resulting from these SFPs releases, have been fully characterized and their extent, activity and impact determined. The two primary radionuclide contaminants of interest were found to be Tritium and Strontium. Other contaminants, Cesium, Cobalt, and Nickel, have been fOWld in a subset of the groundwater samples.
but always in conjunction with Tritium or Strontium. Therefore, while the focus of the investigation was on Tritium and Strontium, it inherently addresses the full extent of groundwater radionuclide contamination. The investigations have further shown that the contaminated groundwater can not migrate off.. property to the North. East or South.
The plumes ultimately discharge to the Hudson River to the West.
Throughout the two years of the investigation, the groundwater mass flux and radiological release to the Hudson River have been assessed. These assessments, along with the resulting Conceptual Site Model, have been used by Entergy to assess dose impact. At no time have analyses of existing Site conditions yielded any indication of potential adverse envirorunental or heaJth risk. Ln fact, radiological assessments have consistently shown that the releases to the environment are a small percentage of regulatory limits.
SOURCES OF CONTAMINATION As stated above, the investigations found that the groundwater contamination is the result of releases from the Unit 2 and the Unit I SFPs. OUf studies found no evidence of any release from Unit 3.
The predominant radionuclide found in the plume ITom the Unit 2 SFP pool is Tritium.
The releases were due (0; 1) historic damage in 1990 to the SFP linerl with subsequent discovery and repair in 1992; and 2) a weld imperfection in the stainless steel Transfer Canal liner identified by Entergy in September 2007, and repaired in December 2007.
To the extent possible, the Unit 2 pool liner has been fully tested and repairs have been completed. The identified leakage has therefore been eliminated and/or controlled by Entergy. Specifically. Entergy has: 1) confirmed that the damage to the liner associated with the 1992 release was repaired by the prior owner and is no longer leaking; 2) installed a containment system (collection box) at the site of the leakage discovered in 2005, which precludes further release to the groundwater; and 3) after an exhaustive Vlll
liner inspection. identified a weld imperfection in the Transfer CanaJ liner that was then prevented from leaking by draining the canal. The weld was then subsequently repaired by Entergy in mid-December 2007. Therefore, all identified Unit 2 SFP leaks have been addressed. Water likely remains between the Unit 2 SFP stainless steel liner and the concrete walls, and thus additional active leaks can not be completely ruled out.
However, if they exist at all, the data indicate they must be small and of little impact to the groundwater.
The Unit I plume is characterized by Strontium from legacy leakage of the Unit 1 fuel pools. At present, the Unit 1 pools have been drained with the exception of the Unit 1 West Fuel Pool which still contains spent fuel. This West Pool leaks water under the fuel building and is responsible for the Unit 1 Strontium groundwater plume disco-vered in 2006. Prior to that time, the previous owner had identified leakage from the West Fuel Pool i.n the 1990's and was managing the leakage by collecting it from are*
configured footing drain that surrounded the fuel building. However, based on the groundwater investigation, it has been detennined that the pool leakage management program was not successful in collecting all of the leakage. As a result, uncollected contaminants released from the Unit I Spent Fuel Pools, past and present, have been observed during the groundwater investigation effort at various locations near the site of Unit I. In response to the finding that the leak collection system was not functioning as believed, Entergy promptly initiated a program to reduce the concentration of radionuclides in the Unit I West Pool's water, beginning in April 2006. via enhanced demineralization water treatment. The planned fuel removal and pool draining will completely eliminate this release source by year end 2008.
EXTENT OF CONTAMINATION The groundwater contamination is, and will remain, limited to the Indian Point Energy Center property, because the migration of Site contaminants is controlled by groundwater flow, which, in tum, is governed by the post-construction hydrogeologic setting.
Plant construction required reduction i.n bedrock surface elevations and installation of foundation drains.
These man-made features have lowered the grOtUldwater elevations beneath the facility, redirecting groundwater to flow to the West towards the Hudson River; and not to the North, East or South. Because of the nature and age of the releases, groundwater contaminant migration rates, and interdictions by Entergy to eliminate/control releases, the groundwater contaminant plun1es have reached their maximum spatial extent' and should now decrease over time.
LONG TERM MONITORING Long term groundwater monitoring is ongoing; a network of multi-level groundwater monitoring installations has been established at the tacility. These "wells'l are located downgradient of, and in close proximity to, both existing and potential release locations. Groundwater testing is perfonned quarterly on the majority of these wells, with the rest remaining on standby to provide added detail, if required. The resulting information is provided on a yearly basis to the Nuclear Regulatory Commission IX
(NRC). The infonnation is used to assess changes in groundwater relative to dose impact assessment and to detect future releases, should they occur.
[0 addition to the groundwater samples from the network of monitoring wells, Entergy obtained various off-Site samples of environmental media including off-Site wells.
reservoirs and the Hudson River. In addition, Entergy participated in a fish sampling program with the NRC and New York State Department of Environmental Conservation (NYSDEC). None of the samples analyzed, including the samples split with regulatory agencies, detected any radioactivity in excess of environmental background levels.
GZA believes thal the recommended remediation technology discussed below will cause the concentrations of radionuclides in the groundwater plumes to decrease over time.
The continued monitoring of groundwater is expected to demonstrate that trend and support the conclusion that the identified leaks have been terminated. However, aZA expects that contaminant concentrations will fluctuate over time due to natural variations in groundwater recharge and that a potential future short term increase in concentrations does not, in and of itself. indicate a new leak. It is further emphasized that the groundwater releases to the river are only a small percentage of the regulatory limits, which are of no threat to public health.
PROPOSED REMEDIATION aZA has recommended the following corrective measures to Entergy, which they are implementing:
L Repair the identified Unit 2 Transfer Canal tiner weld imperfection (completed December 2007).
- 2. Continue source tenn reduction in the Unit I West Pool via the installed demineralization system (ongoing until completion of No. 3 below).
- 3. Remove the remaining Unit I fuel and drain the West Pool (in-process).
- 4. Implement long term groundwater monitoring (in-process).
The proposed remediation technology is source elimination/control (Nos. 1 and 3 above) with subsequent Monitored Natural Attenuation, or MNA. MNA is a recognized and proven remedial approach that allows natural processes to reduce contaminant' concentrations. The associated monitoring is intended to verify that reductions are occurring in an anticipated manner. The Indian Point Energy Center Site is well suited for tllis approach because: \\) interdictions to eliminate or reduce releases have been madej 2) the nature and extent of contamination is known; 3) the contaminant plumes have reached their ma.ximum extent; and 4) the single receptor of the contamination, the Hudson River, is monitored, with radiological assessments consistently demonstrating that the releases to tbe environment are a smatipercentage of regulatory limits, and no threat to public health or safety.
x
1.0 INTRODUCTION
This report presents the results of hydrogeological studies perfonned by GZA GeoEnvironmental. Inc. (GZA) at the Indian Point Energy Center ([PEC) in Buchanan, New York (Site). See Figure 1.11 for a Locus Plan. The report was prepared by GZA under the terms of an agreement with EneTcon Services, Inc. for Entergy Nuclear Northeast, and desc*ribes services completed between September 2005 (the beginning of our services) and September 2007.
OUT investigations were conducted in a cooperative and open manner. Entergy provided full and open access and there were regular and frequent meetings with representatives of the United States Nuclear Regulatory Commission (NRC). the United States Geological Survey (USGS), and the New York State Department of Environmental Conservation (NYSDEC).
Further, we presented our preliminary findings at a number of external stakeholder and public meetings.
From the onset of the investigations, GZA routinely computed the groundwater mass tlux2 and associated radiological release to the Hudson River. Using these data, the potential impacts of releases to the river were assessed by Entergy and compared to existing regulatory thresholds.
At no time did these analyses yield any indication of potential adverse environmental or health risk as assessed by Entergy as well as the principal regulatory authorities. In fact, radiological assessments have consistently shown that the releases to the environment are a small percentage of regulatory limits, and no threat to public health or safety.
In this regard. it is also important to note that the groundwater is not used as a source of drinking water on or near the Site.
This report docwnents two years of comprehensive hydrogeological investigations.
The text of the report describes Site conditions, GZA's investigations. and findings, and presents conclusions and recommendations. Supporting information is provided in tables, on figures and in appendices. To understand how we fonned our opinions. it is important to review the report in its entirety, including Appendix A Limitations.
I.1 PURPOSE The overall purpose of our services was to identify the nature and extent of radiological groundwater contamjnation that originates at [PEe. and assess the hydrogeological implications of that contamination. More specifically, our objectives were to:
Identify the nature and extent of radiological groundwater contamination; Establish the sources of the radiological groundwater contamination; I rigurcs referenced by specific number arc contained as fuJi size drawings in Volume 3 of this report. Additional smaller scale figures. photographs, etc. arc embedded within the text for immcdiatc reference
! Flux. (or mass nux) is defined as the amount ofgroundwnter that tlows through tl unit subsurface area per unit time.
I
Evaluate the mechanisms controlling the groundwater transport of radiological contamination; Estimate both the mass of groundwater transporting contaminants, and the radiological activity associated with these contaminant pathways; Develop a groundwater monitoring network that addresses IPEe's short term and long term needs, and is consistent with the Nuclear Energy Institute's (NEI's)
Groundwater Protection Initiative; and Recommend, as required, appropriate remedial measures.
1.2 BACKGROUND
m August 2005, Entergy was excavating in the Unit 2 Fuel Storage Building (IP2-FSB)
Loading Bay, adjacent to the South wall of the Spent Fuel Pool (IP2-SFP), in preparation for installation of gantry crane foundations required for the Independent Spent Fuel Storage mstallation Project (see Figure 1.2 and the following illustration).
[PEC LOOKING EAST FROM ABOVE THE HUDSON RIVER 2
While removing existing backfill material from along the South wall of the SFP, two shrinkage cracks in the concrete pool wall (about 1164" wide) were observed (refer to Section S.l for additional information). The concrete wall in the area of these cracks appeared damp.
UNIT 2 SFP SHRINKAGE CRACKS IDENTIFIED IN SEPTEMBER 2005 Initially. a temporary, plastic membrane collection device was installed to facilitate water retention and sampling as there was no visibly free-flowing liquid.
Analyses of the collected moisture indicated that it had the radiological and chemical characteristics of IP2*SFP water. The primary radioactive constituent was Tritium. This finding initiated work to terminate the known release from these shrinkage cracks. Pennanent containment of the release, and prevention of any further migration into the subsurface, was accomplished by installing a waterproof physical containment ("collection box") over the two shrinkage cracks prior to backfilling the gantry crane foundations and SFP wall.
This containment was then piped to a pennanent collection point such that any future leakage from the crack could be monitored]. In addition, Entergy also began extensive investigations of the stainless steel liner in the Unit 2 Fuel Pool itself, as well as the integral Transfer Canal. Subsurface investigations were also started to evaluate if the groundwater had become contaminated from the release.
l Subsequcnt monitoring has indicated that the leakage from the crack. which had only been rypically as high as 1 j Uday (peak of about 2 Uday) from its discovery through thc fall of2oo5. has since fallen olf dramatically. (L-Jitcrs).
3
As part of these early investigations, Entergy sampled groundwater on Septemher 29, 2005 from a nearby existing downgradient monitoring well, MW-Ill. This monitoring well is located between the IP2-SFP and the downgradient Hudson River to the West (see Figure
\\.3 for well location). The analysis resulLs, reported on October 5, 2005, indicated an elevated Tritium concentration. The elevated Tritium in MW-l11 was consistent with a release from the shrinkage cracks that had migrated into the on-Site groundwater. Enter6'Y therefore began an extensive investigation to understand the extent of the Unit 2 groundwater contamination and potential impacts to the environment.
Although the early subsurface investigations were focused primarily on potential sources of contamination, the project team also reviewed:
regional hydrogeological information, plant design/construction details, and available Site-specific groundwater monitoring results. This early work led to three conclusions:
The recently identified shrinkage cracks had resulted in releases of Tritium to the groundwater; It was unlikely that contaminated groundwater was migrating off-property to the North, East or South; and Tritium-contaminated groundwater likely had, and would continue to, migrate to the Hudson River to the West.
In response to these three early conclusions, Entergy tasked GZA with developing a network of groundwater monitoring wells. The primary objectives for this network were to facilitate comprehensive investigation of the IP2-SFP Tritium release location, as well as evaluate the potential for releases at other locations across the Site. Additional objectives included:
Monitoring of the southern boundary of the Site (previously identified by others as downgradient);
Monhoring attenuation of the contaminant plume(s) identified on-Site; Early detection of leaks in areas of ongoing active operations, should they occur in the future; and Monitoring of the groundwater adjacent to the Hudson River to provide the required groundwater data for Entergy's radiological impact evaluations.
The groundwater monitoring network ultimately developed by GZA, and supported by Entergy, was comprised of shallow and deep installations at 59 monitoring locations.
These installations were completed in both soil overburden and bedrock. The instaUations generally include multi-level instrumentation which allows acquisition of depth-discrete b'Toundwater samples and automatic recording of depth-specific groundwater elevations via electronic pressure transducers. The wells were drilled in a phased manner, with resulting 4
data being used to modify and guide the work of subsequent investigations. This iterative progression is in accordance with the Observational Method4 approach (see Section 2.0).
During the course of the expanded investigations in 2006, Strontium-90 was detected in, and downgradient of, the western portion of the Unit 2 Transfonner Yard (lP2-TY). While the transfonner yard is located immediately downgradient of the Unit 2 Spent Fuel Pool (fP2-SFP), the source of this Strontium in the groundwater could not reasonably be associated with a release from the lP2-SFP. This conclusion was particularly appropriate when evaluated in light of the sampling data from the upgradient transfonner yard wells and ultimately from wells directly adjacent to the SFP itself. The ongoing subsurface investigation program was therefore further expanded to encompass not only the IP2-SFP source area, but also other potential sources across the entire Site, including Units 1 and 3.
These subsequent phases of investigation ultimately established the retired Unit I plant as the source of the Strontium contamination identified5 In the groundwater.
More specifically, the Unit I fuel storage pool complex, where historic legacy pool leakage was known to exist, was confinned as the Strontium source. This fuel pool complex is cOllectively tenned the Unit I Spent fuel Pools (lP I-SFPs).
Following detection of radionuclides in the groundwater associated with IP1-SFPs, Entergy accelerated efforts to reduce activity in the IP I-SFPs, along with acceleration of the already ongoing planning for the subsequent fuel rod removal and complete pool drainage.
As indicated above, later phases of the investigations encompassed the entire Site, including all three Units (lP I, IP2 and fP3). These investigations found no evidence of releases to the groundwater from the IPEe Unit 3 plant complex. In this regard, it is important to note that the design and construction of the IP3-SFP incorporates a secondary leak detection telltale drain system, in addition to the primary stainless steel liner.
The earlier Unit I and Unit 2 SFPs were not designed with this feature.
- 11. C/se of/he Observational Method In Ihe Inw!sligulion alld MU/Ilforing q!'f1 Spent "'IUd Pool Release. Barvenik. ct.
at.. NEI Groundwater Workshop. Oct. 2007.
- b. Us.: uJ/he Observarimw/ Method ill the Ilemedial Investigation and Cleanup of Crmllllllinaled {.(md. Dt:an. A.R.
and M.1. Barvcnik. The. Seventh Geolechnique Symposium - Geolechnic!ll Aspecl~ of Coni am ina led Land sponsored by the Institution of Civil Engineers. London. Volume XLII. Number I. March 1992.
- c. Advantages and Limitutions of the Observational Method in Applied Soil Mcchanics. Peck. Itl3.. Geotechnique 1969. No.2. 171-187.
, In addition to Strontium. other fudiolluclides (Nickel, Cobalt and Cesiurn) were also sporadically detected in groundwater. rhcse other radionuclides were continuously assessed within the context of the overall hydrologic model.
Based upon their OCCUTTcnce. Strontium. in combination with Tritium. provides full delincation of radiological groundwatcr plumes at the IPEe Site.
5
2.0 SCOPE OF SERVICES This section outlines the scope of OUf two-plus year-long investigation. Consistent with well established hydrogeologic practices, aZA followed the Observational Method.
That is, aZA developed a Conceptual Site Model (see Section 3.0) that described our understanding of groundwater flow and contaminant transport at IPECJ and perfonned investigations to test the validity of our model. In response to test data, we revised the model and/or performed additional testing to clarify findings. This iterative, step-wise pbased approach allows for better focused testing, and a more comprehensive review of data. It also reduces the chances of missing critical information, and generally completes studies in less time. GZA executed the scope in three phases.
2.1 PHASE I Phase I investigations commenced in September 2005. Consistent with the concerns raised by the observed IP2-SFP crack leakage, the Phase 1 investigation program focused on:
- 1) Identifying the groundwater flow paths which would intercept potential releases from LP2-SFP; and 2) Evaluating groundwater contaminant fate and transport mechanisms in this area of the facility. This work included:
Identification, retrieval and evaluation of historic geologic, hydrogeologic and geotechnical reports to form the basis of our initial Conceptual Site Model (CSM);
Development of an initial CSM; Identification, retrieval and evaluation of historic facility Site plans and construction details pursuant to the impact of man-made features on groundwater flow directions and Tritium migration, with subsequent refinement of the CSM; Installation of nine groundwater monitoring wells, a number of which contained multiple sampling levels, in the area of the Tritium release; Installation of four stilling wells6, three within the Discharge Canal and one in the Hudson River. to allow groundwater elevations to be compared to these surface water elevations (to evaluate if the Hudson River is the ultimate discharge point for any potentiallP2-SFP release);
Perfomlance of elevation and location surveys to establish reference points for groundwater elevation measurement; lnstallation of electronic pressure transducers in newly drilled boreholes and previously existing wells to continuously monitor groundwater elevation fluctuations, as influenced by climatic/seasonal variability, tidal influences and the drilling of nearby boreholes (to assess intercOIUlections between boreholes at different locations);
Geophysical borehole testing to provide further bedrock fracture identification, location and groundwater flow information; 6 Stilling wells are typically constructed orslotted pipe or well screl:n. They nrc placed in surface waler bodies to house pressure lran!;()ucers for waler level measuremenl. Their purpose is 10 dampen-out hi~ Irequenc), pressure tluctuation!1-in the water body, typically due 10 Dow-induced lurbulence, such thaI more representative readings can he ohtained.
Stilling wells arc not Included as monitoring..... ells with reference Iu numbers of monltoring wells instulh::d.
6
Packer testing of specific bedrock boreholes to provide initial depth*specific groundwater samples, measurement of depth-specific groundwater elevations and flow capacity of the fracture zones; Completion of the boreholes as screened overburden wells, open bedrock wells, or multi-level monitoring wells as appropriate for the subsurface conditions encountered; Testing of open bedrock and screened boreholes to measure formation groundwater flow capacity; Ground Penetrating Radar (GPR) analysis of the key locations to evaluate top of bedrock elevations relative to preferential groundwater tlow through soil backfill; Sampling of groundwater from the monitoring wells and analyzing the samples for Tritium and gamma emitters; and Computation of the groundwater flux and radiological activity to the Hudson River for use by Entergy in their dose computations.
2.2 PHASE II Phase n investigations commenced in January 1006.
The focus of this work was to:
- 1) Confirm initial fmdings; 2) Better estimate the quantity of contaminated groundwater at the facility that discharges to the Hudson River; and 3) Establish a network of wells suitable for identifying potential leaks at all three units across the Site and for long term monitoring of groundwater. This phase of work included:
Re-evaluation of our CSM to guide the selection of borehole locations and establish testing requirements; identification of accessible areas from which to drill boreholes to measure groundwater elevations and the contaminant concentrations:
Drilling of 23 additional boreholes through soil and bedrock to depths of up to 200 fect, iDcluding coring to provide bedrock core samples for inspection (to locate fractures in the bedrock which likely conduct groundwater flow);
Performance of elevation and location surveys to establish reference points for groundwater e1evation measurement; lnstallation of electronic pressure transducers in newly drilled boreholes to continuously monitor groundwater elevation fluctuations, as influenced by climatic/seasonal variability, tidal influences and the drilling of nearby boreholes (to assess interconnections between boreholes at different locations);
Geophysical borehole testing to provide further bedrock fracture identification, location and groundwater flow infomlation; Packer testing of speciLic bedrock boreholes to provide depth*specific groundwater samples, measurement of depth-specific groundwater elevations and flow capacity of the fracture zones; Completion of the boreholes as screened overburden wells, open bedrock wells, or multi-level monitoring welJs as appropriate for the subsurface conditions encountered; Conducting tests on open bedrock and screened boreholes to measure formation groundwater flow capacity; Ground Penetrating Radar (GPR) analysis of the key locations to evaluate top of bedrock elevations relative to preferential groundwater flow through soil backfill; 7
Sampling of groundwater from the monitoring wells and analyzing the samples for Tritium and additional radionuclides of interest (including Strontium, gamma emitters, Nickel-63 and transuranics); and Re-computing the groundwater flux and radiological activity to the Hudson River (based on the more current data and refined CSM) for use by Entergy in their dose computations.
2.3 PHASE III Phase ill investigations commenced in June 2006. The focus of the Phase ill work was to:
I) Bettcr delineate the extent of Strontium detected during Phase II investigations; and
- 2) Improve characterization of bedrock aquifer properties to allow evaluation of remedial alternatives. This phase of work included:
Re-evaluation of our CSM to guide the selection of borehole locations and establish testing requirements; Installation of additional wells (MW-53 through MW*67 and Ul-CSS) to further delineate the horizontal extent of groundwater contamination (this work was begun in Phase li);
Installation of deep wells (MW-54, -60, -61, -62, *63, -66, and -67) to establish the vertical extent of contamination; Conducting hydraulic tests on boreholes and completed wells to assess the transmissivity of bedrock fracture zones and overburden; Installation of electronic pressure transducers in newly drilled boreholes and existing wells to continuously monitor groundwater elevation fluctuations due to climatic/seasonal variability. tidal intluences and the drilling of nearby boreholes (to assess interconnections betv.reen boreholes at different locations);
Geophysical borehole testing to provide further bedrock fracture identification, location and groundwater flow information; Packer testing ofspecitic bedrock boreholes to provide depth-specific groundwater samples, measurement of depth-specific groundwater elevations and flow capacity of the fracture zones; Completion of the boreholes as screened overburden wells, open bedrock wells, or multi-level monitoring wells as appropriate for the subsurface conditions encountered; Conducting a 72-hour Pumping Test to assess hydraulic properties of the bedrock as welJ as to assess the feasibility of managing Tritium-contaminated groundwater through hydraulic containment; Perfonnance of a tracer test to better assess contaminant migration and transport mechanisms, particularly in the unsaturated zone; Sampling of groundwater from the monitoring wells and analyzing the samples for radionuclides; and Re-computing the groundwater flux and radiological activity to the Hudson R.iver (based on the marc current data and refined CSM) for use by Entergy in their dose computations.
8
3.0 CONCEPTUAL HYDROGEOLOGIC MODEL This section, together with associated figures, constitutes our Conceptual Site Model (CSM). The key components of the model consisted of: the hydrogeologic setting; genera1 groundwater flow patterns; identified contaminant sources; contaminants of potential concern; and identified receptors. GZA used the CSM to guide our investigations, identify and fill data gaps, assess the reasonableness of tindings, and develop parameters controlling contaminant transport. It was an iterative process and, as studies progressed, we modified the CSM to better fit observed conditions.
With completion of the investigations and further refinement of the CSM, our CSM was consistent with both the Site-specific project data and published data for the area.
The CSM incorporates our understanding of Site construction practices as they influence contaminant migration. Critical in this regard is that, according to construction plans, lean concrete was used as backfill material for foundation walls in a number of locations, primarily associated with Unit 1 structures.
We also note that in some areas where construction plans show soil backfill, we found that lean concrete was actually used.
This is likely due to the relatively low cost of concrete during the 1950's and the uniqueness of the construction for these first nuclear power plants. At the subsequently constructed Units 2 and 3, it appears soil or blast rock was the material most commonly used as backfill against foundation walls.
SCHEMATIC REPRESENTATION OF GROUNDWATER FLOW INTO THE SITE FROM THE NORTH, SOUTH, AND EAST 9
3.1 HYDROGEOLOGIC SETTING The Site watershed is limited in areal extent. GZA assumed that the top of the watershed defines a no-flow boundary in the aquifer. The distance from the upgradient no*f1ow boundary located at the top of the watershed, to the riveT. is on the order of 2,200 feet (see Figure 3.1). This length limits the volume of precipitation available for aquifer recharge.
Recharge is further limited by the density of structures and areal extent of paving, which induces direct run-off. An average annual recharge rale of 5.5 inches per year was initially selected7 as representative for the Site area, which is the USGS estimated average in Westchester County where LPEe is located.
3.2 GENERAL GROUNDWATER FLOW PATTERNS Groundwater flow takes place in three dimensions.
In general, flow at the top of the watershed is largely downward and flow near the river's edge is largely upward. In the mid-section of the watershed, flows are predominantly horizontal. Based on the location of the Site in the watershed and infonnation indicating that the top of the bedrock is more fractured, GZA initially estimated, and later con finned that the bonom of the local growtdwater flow to be at or above elevation -200 feet (National Geodetic Vertical Datum of 19298* NGVD 29)9.
Note that temporal and spatial variations in areal recharge rates.
rock heterogeneities, and tidal influences cause local variations from these general flow patterns. In fact, Site growtdwater flow patterns in some areas are dominated by shallow anthropogenic Site features. These [earures include pumping from building foundation drains, foundation walls, subsurface utilities, and flows in the intake structures and Discharge Canal.
Based upon the regional topography, Site topography (see Figure 3.2), anthropogenic influences. and the geostructural sen-ing. even at the initial stages of the investigations GZA expected that groundwater would flow into IPEC from the North, East and South, and then discharge to the Hudson River. with portions of the flow being intercepted by the cooling water intake and Discharge Canal (see Figure 3.3). However. based on aUf review of reports available at the start of the investigations, it was unclear what the role that anisotropic bedrock structure played in grOlmdwater migration.
That is, there was information suggesting groundwater flows would have a primarily southern component (see Section 6.4 for a description of the regional area and Site-specific geologic setting).
1 As discussed in Seclion 6.0. the initial average areal recharge rote of 55 Inche.slyear..... as subsequently increased some..... hllt a<; we ~lincd our CSM.
I The National Gcodctfc Venical Datum of 1929 (N(jVO 29) is the rtnllmcd Sea ~vel Datum of 1929. The datum was renamed bceausc it is It hybrid model. and nQ/ 0 purlf model of nll!tlfl $CQ IIl'ct. the g\\."()id. or any other equipotornl ial surfllC<:'. NOVO 29...... hich is based on "an llveraging" of multiple poilll:; in the US and Canada. is the vertical "sca level" control dlltum established for vertical control sur.eying in the Unitl."d tates of America by the Gcncnil Adjustment of 1929. The dOlum is used to measurt elcwulon or nhhudc nbove. and depression or depth Delow. "mean sea level" (MSL). It is noted that there is no single MSL because it varies from place to place and over time.
- During II mid-phase of the work. we concluded that the bottom of the locul groundwater flow may be deeper. more likely DetWccn devations <200 to -350 feet NGVO 29. This conjecture Wll:l based on the observed venical distribution of headS. bedrock fracture pallems. and the observed contaminant concentrntions at the time:. We: therefore increased our drilling depth 10 350 feel (multi-level monitoring well installa1ion MW.67) 10 investigate this issue.
Subs~ucntly. the mOSt rl."Cent data be:llef lit with a 2()()"foot-deep flow model.
10
Based on our studies, including a full-scale Pumping Test and tidal response testing, we have shown that in the area of groundwater contamination, and on the scale of the contaminant plumes. the direction and quantity of groundwater flow can be estimated using an equivalent porous media model. We state this recognizing that an individual bedrock zone may represent flow in a single or limited number of fractures which over a relatively short distance is not representative of average conditions.
In terms of our equivalent porous media model, this condition represents an aquifer heterogeneity. However, over sufficient volumes of bedrock (which is the case for the work at !PEC), the bedrock groundwater flu.x can be estimated based on an equivalent porous media model using Darcy's LawlO.
3.3 LDENTlFIED CONTAMINANT SOURCES GZA, in cOI~unction with facility personnel, conducted a review of available construction drawings, aerial photographs, prior reports, and documented releases, and interviewed Entergy personnel to identify potential groundwater c*ontaminant sources.
That review, in conjunction with the observed distribution of contaminants, identified IP2-SFP and IPI-SFPs, along with legacy piping associated with Unit I, as sources of the radiological groundwater contamination. The locations of these structures are shown on Figure 3.4. No release was identified in the Unit 3 area. This finding is consistent with.
and reflects, changes in construction practices over time t I,
Refer to Section 8.0 for additional information pursuant to source area descriptjon.
3.4 CONT AMlNANTS OF INTEREST Throughout this report, Tritium and Strontium are discussed as the principal radiological constituents associated with the groundwater contamination investigation performed at lPEe. Both radionuclides served as the mOst representative contaminant tracer tools from the perspective of frequency of observed occurrence, as well as contaminant transport12 across the Site.
Other radionuclides (primarily C5-137, Ni-63, Co-60) were more sporadically identified and isolated to specific locations within the Site.
These radionuc1ides are encompassed by the Unit 2 (Tritium) and Unit 1 (Strontium) plumes.
We also note these other radionuclides carry a smaller potential radiological impact as compared to Strontium. These contaminants were* also continuously assessed within me context of the overall site hydrological model as well as the plume intonnation gleaned from the Unit 1 and Unit 2 plume data. All detected radionuclides have been 10 Infl!rprt!larion of I(wlroulic Tesrs and Implicari(}IIs Towards Represema/il't! £Iememary Volume/or Bedrock Systems.
Thomns Ilallerslero. October 2003. AGU San FrunciKO.
II l'he absence of Unit 3 sources is attributed to the design upgrod~ incorporJlcd in the more recently constructed 11'3-SFP.
11 A combination of Tritium and Strontium allow full charactcri'.alion of nldloJogical groundwater plume nature and C,'<h:nt Ilt the IPEe Site given their divugcnt behavior in the subsurface. Tritium is completely conserved in the groundwalcr with no partitioning to natural or anlhropogl:nic !lubsurfilce mllleriais. Il. IhCTl:fore. moves with and as rasl as the groundwater. and thus serves as an indicator of the leading edge orll recent rclcl1S(. Strontium provides strong partitioning chnrdcleristics and long. half-life. It is. therefore. an indiculor of older. historic releases.
II
accounted for by Entergy in their dose assessment analyses (radiological impact evaluations). AccOunting for these data was perfonned via USNRC Annual Reporting documents that have been made public (year-end 2005 and 2006) and will continue to be reported on (Refer to RG 1.21 report). Additional discussion of the identified sources of contaminants and the properties affecting contaminant migration are provided in Sections 8.0 and 9.0.
3.5 IDENTIFIED RECEPTORS The NRC has set forth guidance for calculations of radiation dose to the public, and IPEe follows this guidance for radioactive effluents, including those from groundwater. WEe is required to perform an environmental pathway analysis to detennine the possible ways in which radioactivity released to the Hudson River can cause radiation dose. Receptors for radioactive releases to the environment are considered to be actual or hypothetical individuals exposed to radioactive materials either directly or indirectly.
Title 10 of the Code of Federal Regulations, Part 50 (I OCFR50) Appendix I states:
"Account shall be taken of the cumulative effect of all sources and pathways within the plant contributing to Ihe particular type of effluent being considered."
10CFR50 Appendix I provides numerical guidelines on liquid releases of radioactivity, such that releases "will not result in an estimated annual dose or dose commitment from liquid effluents for any individual in an unrestricted area Fom all pathways of exposure in excess of3 millirems to the [otal body or 10 miJlirems to any organ. "
fFEC has reviewed the potential pathways that result in dose to the public and are viable for the Site. Potential pathways considered included drinking water consumption, aquatic foods, exposure to shoreline sediments, swimming, boating, and irrigation. As discussed below, drinking water is not a viable pathway for releases to the Hudson River. Regulatory Guide 1.109, "Calculation of Annual Doses to Man from Routine Releases of Reactor Emuents for the Purpose of Evaluating Compliance with 10 CFR 50, Appendix I" provides guidance and acceptable methodologies for calculating radiation dose from environmental releases. The NRC guidance uses the maximum exposed individual approach, where doses are calculated to hypothetical individuals in each of four age groups (infant, child, teen, and adult).
Maximum individuals are characterized as "maximum" with regard to food consumption and occupancy. Regulatory Guide 1.109 describes a pathway as "significant" if a conservative evaluation yields an additional dose increment of at least 10 percent of the total from all palhways. Based on the above description, the only significant pathway for liquid releases is for consumption of aquatic foods; i.e., Hudson River fish and invertebrates.
The specific melhodology used to calculate doses from liquid radioactive effluents is based on NRC guidance and is contained in the Indian Point Offsite Dose Calculation Manual (ODCM). The volume of groundwater traversing the site and discharging into the Hudson River, as estimated by aZA using the data as presented in this groundwater report, is used in conjunction with measured concentralions of radionuclides in groundwater to estimate the total amoun( of radionuclides to the Hudson River, and their potential dose impact.
In 2005 and 2006, groundwater releases resulted in a small fraction of the offsite dose limits established by the NRC for each site. This dose is calculated from measured 12
radionuclides in groundwater, using the methodology in the ODCM.
A simplified description of the methodology is sho"'11 in the figure below.
G)
Determine Groundw(lter flow to Hudson River (Hytlrologlst) 0 All pathways to the environment lire considered Determine activity level in (Enll'ironm'!'Ital Review)
G) riverfront wells Dose is too /ow t measure In the (Well Sampln, 1
Hudson River, CD Delermlne Dilution In bur il can bi ca/cul/J/ed River (TIdal Flows)
CD Use NRC approved methodology to calc:ulale potontl,1 radiation dose SIMPLIFIED GROUNDWATER DOSE CALCULA nON METHODOLOGY Radiation doses are reported annually by IPEC in an NRC-required Annual Radioactive Effluent Report. An overview of the results is shown in the figure below,
- 1.
l t ComparIson or L.lquld EI'Tlu.n1 Dos. Limit <<>
Compa"son 0' Llqu'CI e:l'llu.n. no ** !..lmllS Ie>
Calcul.t_ OW O<>ses BacKground Radlatlon Dos.
m
~'
I-
, l
.... no I-t ~,,,o~
1-f-
r.:ii"i1 1-f-
_..-IlL:.
WI'>oI7.0""Y C.. e...... d C.. cul.....
,-,qU'd _,"U.'"
,-,quid _ '".-.,
'-'QuId !!,"u.no
_._<tv Org.... oo _
_._dY Who'. "_ 00.. Or""" 00 ** LI..,II
... ckO'0u_
~..
005. '-'"'It Lh.. It
'hd'.'".. Do **
COMPARISON OF BACKGROUND, DOSE LIMITS, AND CALCULATED GROUNDWATER DOSE-2006 For the purposes of this study, the migration of contaminated groundwater is the pathway of interest. The contaminants of interest are not volatile; therefore, they remain in the subsurface bedrock, soil and groundwater until discharge to the river.
There is no current or reasonable anticipated use of groundwater at the [PEe. According to the NYSDEC 13, there are no active potable water wells or other production wells on the Il Early in the investigative process, the NYSDEC requested that the New York State Depanmcnt of Health assess the presence of drinking water supply wells in thc vicinity of the Site. Thc NYSDEC informed Entergy and GZA that no drinking waler supply wells were locllted on the East side of the Hudson River in the viCinity of the Site in lune 2006.
13
East side (plant side) of the Hudson River in proximity to the IPEC 14. Drinking water in the area (Town of Buchanan and City of Peekskill) is supplied by the communities and is sourced from surface water reservoirs located in Westchester County and the Catskills region of New York.. The nearest of these reservoirs (Camp Field Reservoir) is located 3.3 miles North*Northcast of the Site and its surface water elevation is hundreds of feet above the lPEe. in a cross-gradient direction and several watersheds away. in addition, groundwater flow directions on the Site are to the West towards the Hudson River.
Therefore, it is not possible for the contaminated groundwater at tPEe to ever impact these drinking water sources.
GroWldwater beneath the rPEe flows to the Hudson River and therefore flows through portions of the river bank and river bottom. The river bank at the Site consists of sections of vertical bulkheads and some rip*rap outside of the contaminated flow zone. The size of the Hudson River and the hydraulic properties of the underlying bedrock preclude natural or pumping-induced migration of contaminated groundwater to the West side of the river.
Therefore, conditions at the [PEe pose no threat to potable water supplies.
In summary, the only pathway of significance for groundwater is through consumption of fish and invertebrates in the Hudson River, and tile calculated doses are less than 11100 of the federal limits. As described above, potable water is not a viable pathway and no dose calculations are necessary in that regard.
GZA utilized Environmental Data Resources. Inc. to cQnduct a search for publ ic water supply wells within I mile of the Sitc. According to records maintained by thc USEPA. Ihere wen: no water supply wells located within the search mdii.
14 According to the Rockland County Deprutment of Health. there are municipal drinking water suPPlY wells operated in Rockland County.
aZA fbnnally requested. through a Freedom of Informlltion Law Application (F01-07*004).
infonnation regarding the elevation of groundwllter in these wells to assess if then! was any potential for IPEC to impact these wells. The information was not made available (0 alA for security n:asons. The closest active drinking wllter well in Rocklllnd County is over 4.5 miles Southwest of the Site on. the West side Orthe Iludson Ri ver.
14
4.0 FIELD INVESTIGATIONS This section provides a description of OUf field activities. TIle studies were conducted in three phases between October 2005 and September 2007. Field activities were perfonned, in accordance with general industry practice and regulatory guidelines, 10 develop and validate our CSM (see Section 3.0).
The field exploration program was developed by GZA in cooperation with Enereon and Entergy. A team of GZA engineers, geologists and scientists was present to observe and document drilling efforts, classifY soil and rock samples, direct field testing (packer tests. etc.)
and collect other hydrogeologic data. Borehole development, well installation and packer testing were performed by GZA and the drilling contractor, Aquifer Drilling and Testing (AD1), New Hyde Park, New York. The exploration program also included the use of geophysical exploration techniques to help identifY W1derground utilities, evaluate the location of the bedrock surface, and evaluate the nature of bedrock fractures in select boreholes. Advanced Geological Services (AGS) and Geophysical Applications, lnc. (GA),
both under QZA's oversight, conducted this work.
The following provides a broad overview of our investigations.
Refer to subsequent subsections for more information.
Geological Reconnaissance Review of Relevant Geological Literature and Previous Reports Site Reconnaissance to Observe Outcrops of Bedrock Geostructural Logging of the Rock Wall within the lP2-FSB Crane Foundation Excavation Test Drilling - Planning, Execution, Post-Drill Activity Review of Existing Utility Plans Surface Geophysical Utility Surveys (to further locate utilities)
VaCUWll Excavation of 39 boreholes (for safety; to reduce risk of encountering underground utilities or structures)
Test Boring Advancement (bedrock borings, overburden borings)
Borehole Development (to remove rock cuttings and drill water; preparation for hydraulic testing in boreholes)
Borehole Geophysical Surveys (to evaluate fractures along the borehole wall)
Monitoring Weillnstallations
- Bedrock Wells
- Open Rock Wells Waterloo Systems
- Nested Wells
- Overburden Wells
- Wellhead Completion 15
Wellhead Elevation SlUVeying Hydraulic Testing to Evaluate Hydraulic Conductivity of Bedrock Specific Capacity Testing Rising Head Hydraulic Conductivity Testing (pneumatic and hydraulic slug tests)
Bedrock Packer Hydraulic Conductivity Testing A PlUTIpmg Test (a 72 hour8.333333e-4 days <br />0.02 hours <br />1.190476e-4 weeks <br />2.7396e-5 months <br /> Pump Test to evaluate the hydraulic properties of the bedrock)
Water Sampling On-Site Sampling of Groundwater, Surface Water and Facility Water Off-Site Sampling of Groundwater and Surface Water Groundwater Elevation Monitoring and Pressure Transducer Data Installation of In-Situ and Geokon Transducers
- Data Retrieval Organic Dye Tracer Testing Injection Well Construction Tracer Introduction Sampling Methods Geophysical Testing - Identification of Preferential Groundwater Flow Paths GroWld Penetrating Radar Surveys at Unit 2, Unit 3 and the Owner Controlled Area (DCA) Access Road Seismic Refraction, GPR and Electromagnetic Surveys between the Protected Area and southern Warehouse As-built locations of the explorations are shown on Figure 1.3. Table 4.1 provides a summary of well locations and installation details. The following sections describe the key aspects of the completed work. Explorations logs, test records and additional information are presented in the Appendices.
4.1 GEOLOGIC RECONNAISSANCE To develop a preliminary understanding of the subsurface conditions expected to occur beneath the Site, GZA reviewed USGS publications relating to the local and regional geology as well as available Site-specific geologic reports. GZA further conducted a reconnaissance of the Site to identify the type of bedrock exposed, relative fracture density and locations of expected overburden.
Specifically included was the logging of the rock wall in the construction excavation at Unit 2 (refer to Section 6.0 for additional detail on Site Geology).
This information was used to help design the subsurface investigation methods.
16
4.2 TEST DRILLING Forty-seven borings were completed by GZA as part of this program, forty-two of these borings were converted to monitoring installations, one was converted to a recovery well and one was converted to a tracer injection pointl5. Boring logs for the bedrock borings and the additional overburden borings are provided in Appendix B. Boring locations and elevations are provided in Table 4.1.
Final sampling elevations are also provided in Table 4.1.
Test Boring/Monitoring Installation locations are shown on Figure 1.3. In viewing the figure, note that test boring designations are the same as the monitoring installation16 designations (see Section 4.3.4). In addition, a tracer injection point was installed along the side of the casing of MW-30 (see Section 7.0 for details).
Prior to advancement of the borings. a ulility identification and clearance program was implemented to reduce the risk of encountering underground utilities, and to maintain the safety of on-Site personnel during drilling activities. GZA personnel, AGS personnel and Site personnel first performed a reconnaissance of the proposed boring locations.
Site personnel then utilized Site plans to assess the potential presence of subsurface utilities in the area of the proposed boring locations.
Following this initial screening, AGS personnel perfonned a surface geophysical survey of the area around the proposed boring locations using GPR and radio frequency utility locating equipment. The results of the survey were marked on the ground surface using spray paint. Entergy personnel performed a final reconnaissance prior to approving the locations, IS Ilorings are defincd as test Sih:S that were excavated with hand held or meohanical drilling devices. Monitoring installations are defined as boreholes (or wd lborc:s) thai were completed to allow groundwllIcr monitoring and gem:rally include multiple monitoring levels over the depth of the boring (either "nested weir" casings within onc borchole or Waterloo muUi-lcvd completions). In several instances. a monitoring instu llation location designation, such as: MW-49, may have two discrete borings. in which case it is counted as two installations. but represented on the figures as II single location for Clarity. Anemptcd borings \\~hich met refusal and had to be rc-drillcd ore not included in the boring counl 16 MoniToring insTallaliolis <Ire commonly referred to as Monitoring wells, which in this usage, may include multiple.
individual well caSings. This generic uSllge is also used hc:rein.
17
SURFACE GEOPHYSICAL SURVEY At thirty nine of the boring locations, overburden was vacuum-excavated until bedrock was encountered, or to the practical limits of the vacuum excavation technique. To further reduce the risk associated with the drilling program, during advancement of the borings to bedrock, a downhole magnetometer was utilized every two feet to assess the presence of metallic objects potentially related to subsurface utilities.
The test borings were performed by ADT with a combination of three drill rigs:
a track-mounted CME LC55 rotary drill rig. a truck-mounted CME 75 rotary drill rig, and an electric track-mounted Davie OK 515 rotary drill rig. The original program consisted of advancing borings into bedrock to desired terminal depths using wire line HQ direct rotary coring techniques.
This resulted in a
nominal 3.SS-inch diameter borehole.
Where overburden was present, either a four-inch or six-inch casing was installed into the rock and grouted in place.
At certain locations where overburden occurred beyond the bottom of the vacuum-excavated test pits, soil samples were collected at 5-foot intervals, from the bottom of the vacuum-excavated test pit, using a 2-inch outside diameter (00) split-spoon sampler driven by a 140-pound hammer falling 30 inches, to characterize soils. These samples were visually classified using the Burrnister Classification System.
At all locations, either vacuum-excavated test pits or hand-excavated test pits were perfonned to clear utilities prior to advancing boreholes. Grab samples were collected during the advancement of the test pits to visually characterize the overburden soils.
18
VACUUM EXCAVATION During the drilling program, rigorous field protocols were implemented to limit the risk of cross-contamination. All down-hole drilling tools, testing equipment, and well materials were steam cleaned or pressure washed prior to use on the Site, subsequent to the completion of a boring, and prior to leaving the Site. Water used during drilling, testing and well installations was drawn from the Buchanan, New York public water supply from on-Site connections.
Waste water, waste soil, and decontamination wash water were placed in 55-gallon drums and transferred to Site personnel for proper disposal.
4.2.1 Bedrock Borings Thirty-eight of the borings were drilled in bedrock. including UJ-CSS which was installed horizontally through the East wall of the Unit 1 Contairunent Spray Sump using hand coring techniques. The borings were completed using rotary techniques with water as the drilling fluid and either pennanent 4-inch or temporary 6-inch casing to keep the borehole open through overburden soils. Once rock was encountered, it was cored using HQ-size double-tube core barrels with diamond studded bits in general accordance with ASTM D2ll3 [6].
Core runs were generally 5 feet in length, with a nominal 3 inch diameter. Shorter or incomplete Tuns were made when the drilling team believed the core barrel to be blocked.
The rock samples were classified and logged by GZA field personnel, and the descriptions and rock quality designations were reviewed and checked by a Senior GZA Geologist. Rock classification was based on the International Society of Rock Mechanics (ISRM) System with adaptation to suit the identified rock and structure.
19
The rock core was logged as soon as practical after it was extracted from the core barrel. The following infonnation was generally noted for each core run:
Depth of core run Percent core recovery Rock Quality Designation (RQD)
Rock type, including color, texture, degree of weathering and hardness Character of discontinuities, joint spacing, orientation, roughness and alteration Nature of joint infilling materials, where encountered Presence of apparently water-filled fractures BEDROCK CORE OBTAINED FROM DRILLING USED FOR EV ALUA nON OF FRACTURES During rock coring activities, potable water was used as a drilling fluid to cool and lubricate the core barrel and remove cuttings from the borehole. The drilling fluid was circulated down the borehole around the core that had been cut, flowed between the core and core barrel, and exited through the bit. The drilling fluid then circulated up the annular space and was discharged at the land surface to a mud tub. The volume of water lost during drilling was recorded and later, during development, an attempt was made to remove the amount lost to the fonnation.
In addition, drilling parameters, such as the type of drilling equipment, core barrel and casing size, drilling rate, and groundwater condition were recorded. Cumulatively, this infonnation provided insights relative to rock conditions, and the potential for the transport of groundwater migration in bedrock fractures.
Bedrock borings ranged in depth from 30 feet below ground surface at MW-33, -34 and -35 to 350 feet below ground surface at MW-67. As described below in Section 4.4, 20
the maJonty of the rock borings were completed as monitoring well locations.
One exception was MW -61, which was abandoned when a length of HQ casing separated in the borehole due to drilling difficulties related to a 70-foot length of clay-filled fault gouge, and could not be retrieved. The boring was subsequently grouted and a second boring, designated MW-66, was advanced approximately 10 feet East of the MW-61 location.
As discussed earlier, one boring, UI -CSS, was instaJled using a hand-held coring machine through the East wall of the IPI-CSS. This borehole was advanced horizontally approximately 70 inches into the bedrock to the East of the Superheater Building.
4.2.2 Overburden Borings In areas where groundwater was encountered in the overburden deposits, overburden (soil) borings were drilled to further evaJuate water quality in the shallow aquifer.
Five borings, designated MW-49, -52, -62, -63, and -66 were advanced immediately adjacent to the bedrock boring of the same name. In addition, three overburden borings, designated MW-38 and MW-64, were advanced at stand alone locations. MW-38 was advanced to assess groundwater quality and migration pathways along the Discharge Canal. MW-64 was advanced to detennine the backfill material and construction properties of the Discharge Canal as it runs beneath the Superheater Building, and was tenninated at a depth of 3 feet when concrete was encountered beneath the slab of the building. Additionally, a tracer injection well (TI-UI -I) was installed within overburden above the North Curtain Drain (NCO) along the North wall of the IPI-FHB.
Seven of the borings were advanced using water rotary techniques and temporary six-inch casing.
MW-64 was advanced using a concrete core until lean concrete was encountered under the building slab.
Seven of the borings were completed as single monitoring wells.
ADVANCEMENT OF BORINGS ALONG RIVERFRONT 21
4.2.3 Borehole Development After drilling was completed and prior to conducting hydraulic tests within a borehole, borehole development was conducted to remove rock cunings from the borings, which could otherwise restrict water flow into the fractures and alter packer testing results, as well as to remove drilling water lost to the fannation during drilling. The boreholes were developed either by pumping and surging ",rith a 3.7-inch surge block and a Grundfos Redi-Flo 2 submersible pump, or by pumping with a submersible pump along the length of the borehole.
Sufficient water was pumped out of the borehole to account for water lost during drilling and until well water was visually free of turbidity.
4.2.4 Borehole Geophysical Analysis Upon completion of borehole development, a suite of geophysical surveys was conducted in select boreholes (borehole geophysics was biased towards the deeper boreholes) by GA of Holliston, Massachusetts to obtain infonnation on the presence of water bearing fractures in the rock. This work took place between November 2005 and July 2007. and involved twenty-three borings MW-30, *3 1, -32, *33, *34, -39, -40, -51, -52,
-53, *54, *55, -56, *57, *58, -59, *60, -62, *63, -65, -66, -67 and RW-I.
GA performed lluid resistivity, temperature and conductivity logging; heat pulse flow meter logging; and optical and acoustical televiewer logging (OTV/ATV). A Mount Sopris model 4MXA or 4MXB logging winch equipped with a Mount Sopris model MGX-I I electronics console recorded conventional logs at each well. All conventional log data was recorded at a.l -foot depth increments.
Fluid temperature and fluid resistivity logs were recorded during the first downward logging run at each borehole using a Mount Sopris caliper probe with a fluid temperaturelfluid resistivity subassembly.
These fluid logs were obtained using a downward logging speed of approximately 4 to 5 feet per minute.
Caliper data were subsequently recorded while pulling the same probe upward at approximately 10 feet per minute.
ATV data were obtained using an Advanced Logic Technologies (ALT) model AB 140 acoustical televiewer probe with a Mounl Sopris winch and an AL T model Abox electronics console. ATV data were recorded at 0.0 I-foot depth intervals with 288 pixels for a 360-degree scan around the borehole wall. Logging speeds were approximately 4 feet per minute with this probe.
OTV data were recorded using an AL T model 08140 probe, also with a Mount Sopris winch and the AL T electronics console. OTY data were stored at depth increments of 0.007 feet, with 288 pixels for each 360-degree scan around the borehole wall.
OTY logging speeds were also approximately 4 feet per minute.
A pair of centralizer assemblies positioned the A TV and OTV probes near the middle of each borehole.
Each centralizer included four stainless steel bow springs, clamped to the probe housings with brass compression fittings, at positions recommended 22
by the probe manufacturer to minimize the risk of interference with the probes' three internal component magnetometers.
Flowmeter data were recorded with a Mount Sopris model HPF-2293 heat-pulse flowmeter probe at specific depths selected from field graphs of the caliper, fluid temperature and fluid resistivity logs.
Flo\\Nlllcter data were initially recorded under ambient conditions. The same test depths were subsequently repeated while pumping at 0.4 to 0.75 gallons per minute (gpm) with a Grundfos, Fultz or Whale pump. The pump was positioned a few feet below the observed static water level in each well. in some cases, the pump was operated so as to maintain the water level some number of feet below the static level (if the well produced little water and the water level was constantly dropping while pumping).
A detailed description of the geophysical logging results for each borehole IS included in Appendix C.
4.3 WELL INSTALLATIONS Bedrock and overburden monitoring installations were constructed in boreholes to allow for future recording of groundwater levels and the collection of groundwater quality samples.
Further, we installed nested piezometers in single boreholes to screen multiple levels of bedrock and overburden within a single borehole and alleviate the need for multiple borings in areas not easily accessed.
For specific well installation details, refer to the well construction logs provided in Appendix D. [n addition, eighteen monitoring wells were previously installed at the Site prior to this investigation and included: MW-I OI, MW-I03, MW-104, MW.I05, MW-I07, MW-!08, MW*I09, MW*IIO, MW*I II, MW-112, U3* I, U3*2, U3-3, U3-4S, U3*4D, U3*TI. U3-T2 and 1-2.
4.3.1 Bedrock Wells Following borehole advancement and testing, GZA evaluated the rock cores, geophysical logs, and other hydrologic and radionuclide test data to assess fracture spacing and potential yield. Using these data, GZA selected intervals within the boreholes to be completed as pennanently screened monitoring wells. The selected well screen intervals were intended to span hydraulically active zones within the bedrock.
4.3.1.1 Open Rock Wells Four bedrock borings, designated MW-33, -34, -35 and -46, were left as open borehole monitoring points.
MW-46 is located in the Unit 3 Transfonner Yard (IP3*Ty), and MW*33, *34 and -35 are located in the Unit 2 Transfonmer Yard (lP2-TY) where. the water table spans the hydraulically active shallow bedrock. The wetted lengths of the borehole were appropriate for one sampling zone at these locations.
Recovery well RW*I, located in (he IP2*FSB truck bay, is also an open borehole. The borehole was installed and a Pumping Test conducted (described in Section 4.4.4) to test the feasibility of using hydraulic containment in the vicinity of Unit 2, should it be found appropriate. This location was used as the pumping well during the Pumping 23
Test. During the interim between completion of the Pumping Test and completion of a hydraulic containment system, a series of temporary packers were installed in the borehole to prevent or limit non-ambient, downward migration of radionuclides through the borehole.
R W-l was also used as a monitoring point during the tracer test.
MW-66 is an open borehole to 200 feet below grade. A Flute liner system was installed in the borehole in September 2007 to limit the vertical migration of contaminants until such time as either a multi-level monitoring well is completed or the boring is abandoned.
Ul-CSS is an open borehole advanced horizontal1y into the bedrock behind the East wall of the Superheater Building. A watertight flange was mounted to the concrete wall of tile IPI-CSS and steel piping was extended vertically upward through the floor of the Superheater Building. The well was completed as a standpipe with shut-off valves and overflow bypass in case of any artesian effect.
4.3.1.2 Waterloo Multi-Level Completion WelJs Twelve borehole loeations, designated MW-30, -31, -32, -39, -40, -51, -52,
-54, -60, -62, -63, and -67, were completed with Waterloo multi-level sampling systems.
The Waterloo system uses modular components which fonn a sealed casing string of various casing lengths, packers, ports, a base plug and a surface manifold.
This configuration allows accurate placement of ports at precise monitoring zones.
Stainless steel sampling pumps are cOJUlected to the stem of each port and individually connect that monitoring zone to the surface. The Waterloo systems are constructed of 2-inch-diameter Schedule 80 PVC risers with 3-foot-Iong packers that inflate to till a 4-inch borehole.
Multiple levels of monitoring ports were installed in each borehole.
In severaJ cases, redundant ports were also installed (typically, within approximately two teet of each other). In the borehole, the associated sampling zones are isolated from each other by a series of packers. The monitoring ports are constructed from stainless steel. Each monitoring port has two openings: one for sampling and one for monitoring piezometric pressures. A sampling pump and pressure transducer are dedicated to each monitoring port.
Each sampling pump is individually connected to the surface manifold by 0.25-inch nylon tubing. In general, monitoring ports were placed within sampling zones adjacent to the fractures that were observed to be the mOst hydraulically active. Sampling zone lengths were varied with the objective of making them less tban ten feet in length, but longer where either: 1) more low transmissivity fractures were required to allow enough f10w for reasonable sampling times, and/or 2) two conductive fractures needed to be captured within a single sampling zone given that the total number of monitoring ports was limited to seven per borehole. Packers were placed at locations where the data (geophysical logging, packer testing, rock core photographs, etc.) indicated that the bedrock was the least fractured. In areas where packer placement could not avoid all fractures, zones with nearly horizontal fractures were favored. The overall objective of packer placement was to achieve a vertical borehole conductivity equal to or less than that of the original bedrock removed from the borehole.
24
A schematic of the data and analysis process used to design the multi-level installations is included below.
EXAMPLE OF DATA AND ANALYSES USED TO DESIGN MULTILEVEL INSTALLA nON The manifold completes the system at the surface. It organizes, identifies, and coordinates the sample tubing, air drive line tubing, and/or transducer cables from each monitoring zone (see photo below of tubing and cabling during system assembly and installation). The manifold allows connection to each transducer in tum, and a simple, one-step connection for operation of pumps. Dedicated pumps allow individual zones to be purged separately; the manifold also allows for the purging of many zones simultaneously from one borehole to reduce sampling times.
25
SAMPLING PORTS, TUBING AND CABLING FOR MUL T1-LEVEL SYSTEM ASSEMBLY AND INSTALLATION 4.3.1.3 Nested Wells Nested monitoring wells were installed in 18 locations, designated MW-36,
-37, -41, -42, -43, -44, -45, -47, -48, -49, -50, -53, -55, -56, -57, -58, -59, and -65.
In general. the nested wells consisted of the installation of one or more one-inch diameter Schedule 80 PVC wells screened at varying intervals in bedrock and a two-inch Schedule 80 PVC well in the shallow West sampling zone of the boring, either in the bedrock or overburden.
In general, well screens conststmg of Q,02-inch slotted PVC pipe were installed at lengths between 2 and 10 feet. Once the screened intervals were selected, the PVC well point was lowered into the boring to the desired depth. Appropriately sized filter pack material was placed from one foot below the screened interval to a minimum of one foot above the screened interval. The depth of the filter pack was measured on several occasions during installation to assess the affects of bridging and verify that the filter pack material was placed at the required depths. The intervals between well screens were sealed using bentonite pellets.
4.3.2 Overburden Wells Three wells, MW-38, 26, 12 were completed as either two-inch diameter or four-inch diameter groundwater monitoring wells. The wells were constructed of Schedule 40 PVC screen and solid riser to ground surface. A O.02-inch slot size was selected for the 26
well screens based on eXIstmg knowledge of the Site soil conditions.
From field observations, the shallow groundwater table was expected to be influenced by daily tidal fluctuations of approximately 2.7 feel. Consequently, well screens were installed such that the top of the screens were above mean high-tide water levels and of sufficient length to accommodate groundwater sampling needs. The annular space around the screen and riser was backfilled with #2 filter sand to approximately 2 feet above the. top of the screen. The remaining annular space was bac*kfilled with bentonite and grout.
In order to sample two intervals in deep fill and overburden deposits observed near the Hudson River (in borings at MW-62, -63, and -66), GZA installed two one-inch Schedule 40 PVC wells, or one one-inch and one two-inch well. at these three locations.
One of the well screens spanned the tidally influenced shallow water table, and one at the top of rock in a more gravel-rich layer beneath silty, historic, river bottom sediments.
In addition, GZA installed one tracer injection well situated in the overburden above the Unit I North Curtain Drain. This well is constructed of two-inch Schedule 40 PVC.
The screened interval was back1il1ed with #2 filter sand to approximately 2 feet above the screen. The remaining arulUlar space was backfilled with bentonite grout. A second tracer injection point was completed adjacent to MW-30's casing.
4.3_3 Wellhead Completion To protect the monitoring installations against damage and the elements, most installations were finished at the ground surface with an 8-inch or l2-inch flush mount protective casing with a concrete pad.
To accommodate the multi-purge, sampling manifold of the Waterloo Systems well installations, the wellheads were completed with a 2 foot by 2 foot by 2 foot well vault. The well vaults were concreted in-place by Entergy subcontractors after the completion of the rock borings. The well vaults are equipped with hinged diamond plate steel lids that are rated for truck wheel loads.
4.3.4 Well Nomenclature GZA designated names to newly installed monitoring installations '7, typically with the prefix "MW-". Nomenclature of single-interval installations, such as MW-33, were designated a number typicaJly indicative of the OI:der in which locations were selected prior to drilling.
Nomenclature of installations containing Waterloo systems or nested piezometers, such as MW*30-69, were designated a number followed by a monitoring depth interval. In Waterloo installations, the depth interval suffix is indicative of the depth to the sampling port from the top of the well casing. Tn nested piezometers. the monitoring depth interval suffix is indicative of the depth to the bonom of the piezometer from the top of the well riser. These depths are rounded to the nearest fool.
Throughout the course of the investigation, alterations were made to well casings and adjacent ground surfaces due to equipment installation, hydraulic conductivity testing,
!7 Monitoring installarions are commonly referred to as J.. fonil(lring wells. which in this usage, may include multiple, individual well casings. This generic usage is also used herein.
27
well vault installation, and Site construction activities. In May 2007, GZA reassigned the names of multilevel installations to maintain the above described nomenclature basis as an easily verifiable tool in the field. Changes in installation nomenclature are provided in Table 4.2. It should be noted that the provided groundwater and tracer test analytical data, piezometric data, well construction and development logs, transducer installation logs, sampling logs, hydraulic conductivity testing logs, and survey reports dated prior to May 2007 reference the original designated installation nomenclature.
4.3,5 Wellhead Elevation Surveying As-built surveys of the newly installed monitoring installations were pertbmled in December 2005, March 2006, April 2006, November 2006, January 2007, and May 2007 by Badey and Watson, Inc. Figure 1.3 reflects the surveyed locations. The survey results are swnmarized in Appendix E and in Table 4.1. Note that Appendix E survey reports dated prior to Ma.y 2007 reference original installation nomenclature. Table 4.3 includes changes in casing and ground surface elevations and dates of a1terations and resurveys throughout the course of the investigation. Elevations are reported with respect to the National Geodetic Vertical Datum of 1929 (NGVD 29)18, which is also the datum used by the plant.
4.4 HYDRAULIC TESTING Four types of in situ tests were performed on existing and newly installed monitoring wells to characterize hydrogeologic properties of the bedrock and overburden. and facilitate the selection of well screen and piezometric sampling intervals. These included short duration specific capacity tests, rising head hydraulic conductivity tests, bedrock packer hydraulic conductivity tests, and the Pumping Test. The following sections describe the equipment and procedures used during this testing program.
4.4.1 Short Duration Specific Capacity Tests A total of eight specific capacity tests and eight extraction te~ts were performed to assess hydraulic conductivity (K). See Table 4.4 for a summary of hydraulic conductivity data.
The testing was conducted by pumping water from the well at a constant rate in order to achieve "measurable drawdown>l within the well that would stabilize after a relatively short period of time.
"Measurable drawdown" was considered between 1.5 and 1 0 feet for the purposes of this study.
Once drawdown apparently stabilized, pwnping was allowed to continue at a constant rate for at least thirty additional minutes before pumping ceased.
II The National Geodetic Vertical Datum of [929 (NOVD 29) is the renamed Sea LevcJ Datum of [929. The datum was renamed because il is a hybrid model. and nol a pure model of mean Sf!a It vel. the wiQ, or any other equipotential surface. NGVD29, which is based on "an averaging" ofmultip[e points in the US and Carmda. i~ the vertical "sea leve["
control dalUm established for vertical control surveying in the United States of America by the General Adjustment of
[929. The c.laturn is used 10 mClISure elevation or altitude above. und depression or depth below. "mcun sea [cvcJ" (MSL). It is noted that there is no single MSL. because it varies from place to place and over time.
28
If measurable drdwdown within the well could not be achieved, and the maximum capacity of the pump was reached, pumping was allowed to continue at a constant rate for approximately thirty minutes, and the pump was turned off. If the characteristics of the monitoring well and inunediately surrounding hydrogeology did not allow for a more suitable method of hydraulic testing, the well was characterized as having a K value "greater than" the value estimated at the maximum pumping rate.
If stabilized drawdown within the well could not be achieved, and the water level in the well continued to decline after attempts to minimize pumping rate to the minimum pumping capability of the pump, the pump was turned off. If alternative methods of testing could not be appropriately implemented due to well characteristics, water levels during the recovery period afthis test were analyzed and interpreted for K values.
A Gnmdfos n Readi-Flo submersible pump or peristaltic pump was used for specific capacity testing, and drawdown was measured using an electronic water level metcr and/or pressure transducers.
Flow rates were either measured using an in-line flow meter, or estimated by measuring the time required to fill a calibrated container. Transducer-logged water level measurements were typically recorded at thirty second or one minute intervals, while manual water level measurements were typically logged every one to five minutes.
The entire pumping duration for each test was typically between thirty and ninety minutes.
OZA performed specific capacity tests between January 2006 and April 2007.
Measurements were also recorded during borehole development. The logs are included in Appendix F.
4.4.2 Rising Head Hydraulic Conductivity Tests A total of forty-three rising head hydraulic conductivity tests were perfonned at eighteen monitoring wells at the Site. Rising head K tests (slug tests) were performed in MW-36-41, 53, 57, 64, and 51 via traditional slug testing. Pneumatic slug tests were performed in monitoring wells MW-53-120, 24, 24, 35, 54, 85, 20, 45, 65, 31, 45, 68, and 80. Hydraulic conductivity (and trWlsmissivity) estimates were then calculated from those results. The calculations for the hydraulic conductivity estimates are provided in Appendix G.
At each of the traditional slug tested monitoring wells, the resting (static) water level was measured along with the depth and diameter of the well. A pressure transducer was installed within the screened portion of the tested well to record water level measurements at 10 second intervals. Pressure transducers in immediately adjacent wells also recorded water level measurements at 10 second to one minute intervals. During the first part of the slug test a rod (slug) of approximately 7 feet long was quickly inserted into the tested well below the water table in order to nearly instantaneously displace a volume of water equivalent to the volume of the slug. Tbe raised head of the water column was then dissipated back down to its initial static level. When equilibration at static water level was reached a rising head test was conducted. The slug was quickly withdrawn from the monitoring well, resulting in a nearly instantaneous decline in the water level within the tested well. The lowered head of the water column recovered to its initial static water level.
29
At each of the pneumatic slug tested wells, static water level was recorded, as well as the depth and diameter of the well.
Pressure transducers were installed within the screened portion of the tested well and in adjacent wells to record water level measurements at 1 to 3 second intervals. A pneumatic slug test well head was attached and sealed to the top of the tested well (see enclosed photo below). The well head was then pressurized using compressed air in order to lower the water column to a predetennined depth that was measured using pressure transducers. The water column was not pennitted to decline below the top of the well screen. When pressure transducer readings stabilized and the water level in the well was below the water level indicated, the air pressure was instantaneously released through a valve on the pneumatic slug test well head, and the water column was allowed to recover to its initial static water level.
PNUEMATIC SLUG TEST WELL HEAD INSTRUMENTATION Slug test logs are provided in Appendix H. Estimated K values are provided in Table 4.4. Figure 4.1 represents a diagram of the pneumatic slug test well head.
4.4.3 Bedrock Packer Extraction Hydraulic Conductivity Testing Under the direction of GZA personnel, ADT conducted 186 packer hydraulic conductivity tests between November 2005 and August 2007 in boreholes MW-30, -31, -32,
-39, -40, -51, -52, -54, -60, -62, -63, -66 and -67.
30
PACKER TESTING OF MW-30 WITIDNIP2-SFP EXCAVATION Bedrock packer hydraulic conductivity testing (packer testing) was perfonned to estimate the equivalent hydraulic conductivity of the bedrock in the vicinity of the borehole locations. The use of packers permitted the localization of a specific depth interval within a bedrock borehole for sampling and hydraulic conductivity testing. The primary hydraulic conductivity of unfractured marble is insignificant. Bedrock groundwater flow, therefore, is controlled by fractures in the rock fonnation.
However, not aJi rock fractures are hydraulically active. Accordingly. packer tests were used to assess which rock zones have the ability to transmit measurable quantities of groundwater, and to estimate the equivalent hydraulic conductivities of those fractures.
During packer testing, water samples were collected for Tritiwn analysis for each tested interval in all boreholes except MW-40.
Water samples were also collected for Strontiwn analysis for every other tested interval in boreholes MW-54. -60, -62, -63, -66, and
-67.
Prior to the initiation of packer testing at the Site, the packer assembly was pressure tested. Also, prior to the start of packer testing at each borehole, all downhole equipment was disassembled and steam cleaned. The submersible pwnp was removed from the packer assembly and decontaminated using a fresh water and Alconox solution.
A quality assurance/quality control (QNQC) sample was collected 1T0m this pump after the decontamination process was completed. After reassembly of the packer equipment, packers and air lines were tested for leaks.
Packer tests were perfonned using an assembly composed of two inflatable bladders, or "packers", with a length of perforated pipe making up the lO-foot test zone between the two packers. A Grundfos Rediflo II submersible pump was placed within this IO-foot-long test zone.
Pressure transducers were positioned above, within and below the test zone.
31
Using a drill rig hoist, the packer assembly was lowered on two-inch-diarneter Schedule 80 pipe to the appropriate lest depths within each tested borehole. See Figure 4_2 for a schematic of the packer test assemblage.
Water levels above, within.. and below the tested zone were recorded at ten second intervals using pressure transducers. Packers were inflated with 160-195 psi ofrutrogen, and water levels were allowed to equilibrate. Once pressures had equilibrated, the pump was turned on and the tested zone was slow purged for at least ten minutes at a rate of 2 to 10 gallons per hour (gph). During this initial purge, a sample was collected for Tritium analysis in boreholes MW-JO, MW-31, MW-32, MW-39, MW-Sl and MW-S2.
Immediately following this initial purging period, the pumping rate wa') increased to a rate of 0.5 to 4 gallons per minute (gpm) in order to achieve drawdown of approximately 10 to 30 feet within the tested zone.
During drawdown. pressure transducer data was observed and compared to assess the potential for cross-zooe communication, either through fractures interconnecting around the packer or incomplete seals by the packers. If significant drawdown could not be achieved. a short term sustained yield rest was conducted. Once significant drawdown was achieved, or sustained yield was maintained for a1 least 30 minutes, a sample was collected for Trititlm analysis. The pump was turned off, and the water level within the test zone was allowed to recover for either 30 minutes or until 80 percent recovery was achieved.
For test zones in which sufficient recovery had been achieved, a final sample was collected for Tritium analysis. This sample was collected from all packer test zones except in borehole MW-40.
Tn some test zones, as noted above, an additional sample was collected for Strontium analysis.
After samples were retrieved, the packers were deflated and pressure transducer data was collected.
Packer test intervals and test pressures were measured in the field and recorded by GZA personnel along with all pertinent testing data. Hydraulic conductivity calculations and methodologies are presented in Appendix G. Packer test result swnmary sheets are presented in Appendix I. Table 4.4 summarizes hydraulic conductivity data collected during packer testing.
In addition to the analyses referenced above. depth-specific borehole transmissivity values were also computed by the USGS using the heat pulse flow meter data collected during the geophysical logging. These data generally confIrmed the packer testing values computed as discussed above (see figure below for an example comparison). In some cases however, these two methods did not correlate well, as reflective of the limitations inherent with each method. For example, the heat pulse flow meter analyses yielded lower transmissivity values where the packer testing transducer data indicated leakage around the packers. In other cases, the heat pulse flow meter analyses proved to be too insensitive to measure lower transmissivity values.
32
~
'..,cOlI MW*62
~
.L
\\
.~
T T
.ro L
=
COMPARISON OF PACKER TESTING TO HEAT PULSE FLOW METER ANALYSIS OF TRANSMISSIVITY 4.4.4 Pumping Test GZA conducled a step drawdown, constant rate drawdown, and aquifer recovery test in recovery well RW-J ncar the lP2-SFP as shown on Figure 1.3. Collectively, these tests are referred to as the "Pumping Test." The Pumping Test was perfonned in general accordance with our Standard Operating Procedure (SOP) dated October 11. 2006 and submitted as part of the "Pumping Test Repon" dated and submitted to Entergy on December 8. 2006.
A schematic of the Pumping Test data, testing and pumping equipment, and data monitoring is provided below.
RW-1 Pumping EQUIPMENT, MONITORING AND DATA FROM PUMPING TEST OF RW-l 33
Prior to the Pumping Test, GZA installed select instrumentation including flow meters, precision gauges, and valving at the weU bead to control floW' and to collect samples, and transducers in wells and drains to measure water level response to pumping.
aZA conducted the Pumping Test by extracting groundwater from RW-l at the following average flow rates:
Srep Drawdown 1012512006 1012512006 2 gpm for 88 minutes 4 gpm ror 77 minUies 5 gpm ror 63 minutes PUMPING TEST
SUMMARY
TABLE During the Pumping Test, we monitored and recorded the following:
Water level elevations with 75 pressure transducers at 44 groundwater monitoring wells at the Site. Water levels in the 15 primary monitoring wells (i.e.~ 1.. 2, MW-30, -31, -32, -33, -34, -35, -36, -37, -42, -47, -51, -52, -53, and -Ill) were monitored once per minute. The remaining 29 wells (MW-38, -39, -41, -43, -44,
-45, -46, -48, -49, -50, -54, -55, -56, -57, -58, -59, -60, -62, -63, -65, -108, -1 09, U3-2, U3-3, U3-CI, U3-TI, U3-T2, U3-4D, and U3-4S) were monitored hourly.
Water quality parameters; we also collected groundwater samples for Tritium and Strontium analysis during the step drawdown and constant rate drawdown test at RW-l.
Flow rates at the !PI -NCO and LPI-SFDS, and the LP2-Curtain Drain; generally at the frequency and using the methods stated in the SOP.
Precipitation via data available from the on-Site meteorological tower or via information available at www.wunderground.com for the surrounding area.
34
c;n) g 0 ; * *
- U...
10.00 1
2."
0." -
4" 10/31/2006 1 111/2006 MW-.30*88
/
11I2l2006 I1I312OOl1 llW2000 1115I200I1 11 I&l2006 I1n/2006 11/812006 Tim. (lIY.)
EXAMPLE OF TIME VS DRA WDOWN CURVE FOR MW-30 The Pumping Test activities are further detailed in our December 8, 2006 report.
The results of the Pumping Test are described in Section 6.0.
4.5 WATER SAMPLING Sampling of on-Site groundwater and surface water sources and off-Site groundwater and surface waler sources was conducted during the period of Ihis study. The locations and methods of sampling are described in the following sections. The results of the sampling are discussed in Section 10.0.
4.5.1 On-Site Groundwater Sampling On-Sile groundwater sampling commenced in Augus12005. upon observation of the moist shrinkage cracks in the 1P2-SFP wall. Through May 2007, sampling was conducted primarily by Entergy personnel. During this period, GZA personnel collected groundwater samples only during packer testing and when conducting low flow groundwater sampling at monitoring wells MW-30 and MW-42.
After May 2007, GZA personnel conducted all groundwater sampling. Over 700 groundwater samples were collected during the study.
aZA and Entergy personnel collected groundwater samples using traditional purge techniques, modified purge techniques, or low flow sampling techniques. Groundwater samples were collected from specific intervrus in monitoring wells MW-30 and the 2-inch diameter well-screened interval of MW-42 using low [low purging and sampling methods described in the USEPA's Low Flow Purging and Sampling Guidance document.
These sampling techniques are described in the following sections.
35
4.5.1.1 Purging At the early stages of the project. Entergy personnel sampled open borehole wells and nested piezometers by purging the traditional 3 to 5 times the volume of water standing in the well casingl9, This was accomplished with either a dedicated submersible pump. a peristaltic pwnp with dedicated tubing, or a Waterra foot-valve pump with dedicated tubing.
As the investigation proceeded, GZA became concerned tbat the standardly-required purge volume could force unrepresentative displacement of contaminants ill the low conductivity bedrock through sampling-induced drawdOWD in the wells. We therefore reduced lbe purge volume, for wells not low flow-sampled, to 1.5 well volumes for the remainder of tbe investigation.
This modification to the sampling procedures was discussed with the regulators.
By May 2007. low flow sampling procedures had been adopted and implemented for all wells.
4.5.1.2 Low Flow Sampling The low flow sampling method allows collection of groundwater samples representative of ambient flow conditions at discrete sampling 7.ones, while limiting the accwnulation of wastewater, mobilization of contaminants, and turbidity of samplcs by reducing pumping rate and drawdown. GZA collected low flow groundwater samples using peristaltic pumps, Grundfos Readitlo 11 submersible pumps, and several models of submersible pumps manufactured by Proactiv. Low flow samples were also collected at discrete sampling intervals of deeper boreholes using Solinst Multilevel Waterloo sampling systems. The use of Waterloo systems for low flow sample collection is swnmarized in the following section. With the exception of wells MW-30 and MW-42, aZA began low now sampling in May 2007. aZA collected samples from MW-30 and MW-42 using low flow techniques starting in January 2006.
aZA collected low 110w samples by slowly pwnping from a predetermined well depth while monitoring water quality parameters, including pH, specific conductance, temperature. turbidity, dissolved oxygen, and oxygen reduction potential CORP).
Water quality parameters were monitored using a Horiba U22 water quality meter with an in~line flow-through cell. Pumping rates were typically between 100 and 400 ml per minute, and drawdown \\vithln the well was typically limited to between 0.1 and 1.0 foot.
GZA recorded water quality parameters, water level, and flow rate every five to ten minutes during a pre-sampling purge which lasted generally between one half hour and three hours. Samples were collected upon stabilization of water quality parameters listed above. Low flow sampling logs are provided in Appendix J. Note that sampling logs dated prior to May 2007 reference original well nomenclature.
19 Water quality parameters during well purging were not measured by Entergy personnel as part of their groundwllter sampling rounds.
36
4.5.1.3 Waterloo Low Flow Sampling Low flow sampling was also conducted in Waterloo installations at MW*30,
-31, -32, -39, -40, -51, -52, -54, -60, -62, -63, and -67. Samples were taken from discrete intervals unless the interval was depressurized, in which case 1.5 well volumes were purged prior to sampling.
LOW FLOW SAMPLING OF MW-30 4.5.1.4 Discrete Interval Packer Sampling During packer testing prior to installation of Waterloo systems, alA collected groundwater samples representative of several distinct elevations within each borehole. GZA collected water samples for Tritiwn analysis for each tested interval in all boreholes except MW-40.
Water samples were also collected for Strontium analysis in boreholes MW-54, -60, -62, -63, and -66.
Sampling procedures were described in Section 4.4.3.
4.5.2 Oo-Site Surface Water Sampling On January 19,2007, aZA collected samples from the Discharge Canal and Hudson River to evaluate major cation geochemistry. This sampling was designed to help us assess potential sources of water found within monitoring wells MW-38 and -48. Samples were collected with dedicated high density polyethylene bailers. In addition, Entergy routinely collects composite water samples from the Discharge Canal to evaluate the discharge of radionuclides to the Hudson River. These samples are collected using peristaltic pumps at locations indicated in the Annual Radiological Environmental Operating Report (AREOR).
37
4.5.3 Off-Site Groundwater Sampling At the beginning stages of the investigation, prior to a thorough understanding of the hydrogeology of the Site, several off-Site groundwater wells were sampled by Entergy personnel to assess the potential for off-Site contamination. These data are presented in the AREOR and the sampling is conducted under the Radiological Environmental Monitoring Program (REMP), During the course of this study. the normal sampling frequencies were increased to either monthly or quanerly to assess regional background concentrations of contaminants of interest. These sampling points included: four USGS monitoring wells, three LaFarge property wells, aod the Fifth Street well in Buchanan. Figure 4.3 shows the locations of the USGS Wells.
Figure 1.3 portrays tbe location of the LaFarge wells.
Please refer to the AREOR for the location of the Fifth Street well.
USGS Wells - On December 5 and 6, 2006, GlA personnel, accompanied by a New York State Department of EnvironmentaJ Conservation (NYSDEC) representative.
collected groundwater samples from four USGS groundwater monitoring wells to assess background concentrations for Tritium. Strontium and Cesium in the region. The wells were located in Harriman State Park. Rockland County, (R0543); Carmel, New York, Putnam County (PI21?); Fort Montgomery, New York, Orange County (local municipal water monitoring well); and Doodletown, New York, Rockland County (RO 18). All four monitoring wells were completed in bedrock. The NYSDEC provided GZA with borehole geophysical data.
All four wells exhibited upward vertical gradients. GlA selected sample localions based upon the flowmeter data so as to sample the groundwater at a depth just below where it was presumed to be exiling the borehole. The groundwater samples were transported to Entergy under chain of custody procedures. Entergy personnel then shipped ule samples to Areva Laboratories in Westboro, Massachusetts for anaJysis of Tritium, Strontium and Cesium.
LaFarge WeUs - GZA personneJ supervised the collection of groundwater samples from the L.farge property immediately South of the Site from groundwater monitoring wells MW-l through MW-3.
Samples were collected by LaFarge's environmental consultant, Groundwater and Environmental Services, inc., under the oversight of Entergy personnel, GlA and NYSDEC representatives on September 19. 2006.
Groundwater samples were collected using a bladder pump following low flow procedures described below. The depths of the wells are shown on Table 4.1.
Fiflh Street Well - Entergy personnel, accompanied by NRC and NYSDEC personnel, collected samples from the Fifth Street well in Buchanan, New York on November 30, 2005. This well is a former private drinking water well no longer in use.
4.5.4 Off*Site Surface Water Sampling During the course of this study, off-Site surface water was sampled at the following locations: the Camp Field Reservoir and the New Croton Reservoir: Algonquin Creek, Trap Rock Quarry, the LaFarge property (Gypsum Plant) outfall, and the Hudson River (see Figure 4.4 for the locations of the Reservoirs). The sampling frequency discussed in the AREOR was increased during the investigation.
Detailed sample locations are discussed in the AREOR.
38
4.6 PIEZOMETRIC LEVELS AND PRESSURE TRANSDUCER DATA GZA measured piezometric levels at 67 locations at the Site over time (between October 2005 and September 2007) using a system of electronic pressure transducers. These measurements were converted to gToundwater elevations (NGVD 29) by referencing the depth of the transducer below the water table at a given time to the elevation of the top of the monitoring well riser. GZA used the resulting data to estimate hydraulic properties of the soil and bedrock, and assess the effects of precipitation. rida1 influences, seasonaJity. and pumping on groundwater flow patterns.
This section describes the methods we used to collect and manage this data. Discussions on the use of the data are presented in Sections 6.0 and to,O.
4.6.1 Transducer Types and Data Retrieval GZA used two types of transducers, depending on the well type and application.
In open wells, GZA installed MiniTroU and LeveiTroll transducers, whicb are vented pneumatic transducers with internal data)oggers. These transducers are manufactured by In-Siru Inc. In wells equipped with Waterloo systems, GZA installed non-vented vibrating wire transducers manufactured by Geokon Inc. Each of these transducers was connected to a Geokon datalogger box located within the well vaull.
GZA selected and installed pressure transducers within the appropriate operating pressure range required for each well or well interval. Table 4.5 provides the accuracy of lhe transducers as reported by In-Situ and Geokon. This table also provides tbe type of transducer used in each well or well interval.
GZA collected data from In-Situ transducers typically every one to three months. or as needed. We cxponed data collected from each transducer from data files recognizable only by Win-Situ software into Microsoft Excel spreadsheets. Generally, no external data manipulation was required for these data reports. On occasion, adjustments to data were required to correct for daylight savings time, or to correct for measured disturbance of the transducer position within the well.
GZA collected water level dala from each Geokon dntalogger typically every two weeks to Iwo months, or as needed. AHer collection, we exported the raw data into Excel spreadsheets and converted reported water levels to water elevations. Because the Geokon transducers are not vented, we adjusted total pressures to account for barometric pressure changes.
Into each data report, GZA incorporated: 1) the barometer reading recorded during wellhead zeroing of the respective transducer; and 2) the barometric pressures recorded at or near the Site at the time the total pressures were recorded. Barometric pressures for this project were recorded on an on-going basis on Site using a Geokon transducer exposed to atmosphere. At different times, the barometric pressure transducer was instaUed several feet above the ma.ximwn water table in MW-3 1, MW-65, and MW-56. For verification, GZA also used barometric pressure data collected by West Point Military Academy, less than ten miles from the Site.
39
4.6.2 Oata Availability and Preservation A compact disk containing piezometric data collected between October 2005 and September 2007 is provided in Appendix K. The data is organized by weU number in Excel spreadsheets. Note that piezometric data dated prior to May 2007 reference original well nomenclature.
Graphs of water levels between October 2005 and February 2007 are presented in Appendix L. Transducer installation logs are provided in Appendix M. As indicated by the legend on the first sheet of this Appendix, colors on these graphs illustrate changes in groundwater temperature. Each graph presents water levels from wells that are grouped together based on proximity to each other and association with selected Site features.
Well locations arc shown in Figure 1.3.
4.7 TRACER TESTING To further test the Conceptual Site Model and assess groundwater flow paths fTom the source areas, GZA conducted an organic tracer test consisting of the injection of Fluorescein (a common dye used in anti-freeze) at a tracer introduction point located close to a potential source of Tritiwn at IP2-FSB.
The injection well was installed approximately four feet South of the expansion crack observed in the South wall of the IP2-SFP, adjacent to monitoring well MW-30. The injection well was designed to aJlow the injection of tracer onto the top of bedrock located at elevation 52 feet. This elevation corresponds to the bottom of the IP2-SFP. Tracer was then gravity fed into the injection well and nushed with water. After injection. routine sampling and monitoring for the presence oflracer in Site wells commenced and continued for 27 weeks:20.
The tracer introduction was made 00 February 8, 2007. Tap water was introduced into the injection well adjacent to MW-30 beginning at 10:30 hours. By 10:41 hours. 30 gallons of water had been introduced into the injection well to wet the surfaces of the materia'! down gradient from the injection well. The water introduction was then suspended while ten pounds of Fluorescei.n dye m.ixture containing approximately 75% dye and 25% diluent, all of which had previously been dissolved in ten gallons of water, was introduced into the injection well. The dye mixture was introduced between 10:42 and 10:50 hours. Tap wat'er introduction was reswned at 10:5 I hours and continued until 11 :40 hours. A total of 210 ga110ns of water was used: 30 gallons to wet the surfaces, 10 gallons to dissolve the tracer, and 170 gallons to flush the tracer out of the dry well into the surrounding bedrock fracture system. Water introduction was made at a mean rate of three gaJlons per minute.
Sampling and monitoring continued through mid-August 2007, which constituted the completion of the test. The well locations monitored during the organic tracer test and the sampling results are presented in Appendix N.
- !O In addition 10 the romine sampling, specific wells were sampled for a longer period of lime as pan of shon term variBbility le!:Iing (see Section 9.0).
40
The following sections describe the key elements of the test. The results of the tracer test are discussed in Section 7.0.
4.7.1 Injection Well Construction Following excavation of soil and rock along the southern wall of the 1P2-SF? for the construction of a new foundation for a heavier crane, the top of rock was exposed along the South wall of the [P2-SFP at elevation 52 feet.
Prior to pcuring a mud-mat, construction of the crane foundation and backfilling of the excavation, GZA installed one groundwater monitoring well (MW-30) and one dye injection weU. The dye injection well was constructed of one-inch Schedule 40 PVC pipe which terminated at elevation 52 feet.
In order to provide a reservoir for the dye to accumulate in prior to seeping into bedrock fractures, a one-foot-thick layer oflh-inch crushed stone was placed on the top of rock over an area approximately 6 feet by 6 feet square. A mud-mat was poured over the crushed stone layer and across the entire Ooor of the excavation.
The excavation was then backfilled. This injection well design allowed for the dye to be injected on the top ofrock and infiltrate into the bedrock in a similar manner as water leaking from the South wall of the IP2-SFP.
4.7.2 Background Sampling Prior to injection of dye, aZA collected background samples to assess the potential of Fluorescein to be present in the subsurface.
Almost all sample locations (which included manholes, surface water bodies, nested weJls, Waterloo wells) were sampled for approximately one week periods two to five times prior to dye introduction. This set of data helped in the selection of dye type and quantity, and assured that background levels of Fluorescein were not an obstacle to conducting the groundwater tracing investigation.
4.7.3 Sampling Stations Sampling stations were selected by GZA for their relevance to the project.
Some stations were established as control stations.
Control stations were established to detect any fluorescent compounds not introduced as part of this investigation which might enter the study area Most sampling stations were established to detect dyes introduced during lhis investigation.
Sampling stations included manholes into the Site drainage system, open waters such as the Discharge Canal and the Hudson River, clusters of nested wells, open borehole wells, and wells with Waterloo packer systems installed. Primary reliance for the detection of dye was placed on activated carbon samplers except at Waterloo locations. One carbon sampler was placed in each well and two were placed in open water locations and in manholes. Open water locations may have strong currents that could damage or wash away a sampler. Placing two samplers at Lhese locations helped ensure that data would be collected for any given time interva1 and provided duplicate samples for quality assurance.
At Waterloo wells, water was the only sampling medium.
Carbon samplers are continuous. accumulatlve samplers that virtually assure that dye migrating with groundwater is not missed at sampling locations. These samplers, 41
however. provide infonnation on the concentration of dye at a specific time.
Because \\vater is an instantaneous sample instead of a continuous sample the Water100 wells were sampled more frequently.
The sampling schedule was designed to help ensure that the time the tracer arrived was recorded, and that it would be unlikely that a transient event would fail to be detected at any sampling location. The latter point only applies to the Waterloo sampling locations, since carbon packets collect samples continuously. Grab samples of water only represent the conditions at the instant the water is collected.
High frequency (or high intensity) sampling stations were selected based primarily on three criteria:
The boundaries of the Unit 1 plume. Most wells that are located within the plume were sampled frequently.
The premise that non*detections of dye could be as important as detections.
Therefore, a "halo" of wells expected to have no detectable dye were sampled surrounding the Unit I plume so that the boundaries of the tracer plume would be well defined.
That there was the possibility of poor correspondence between the tracer plume and the Unit I plume at some locations, and that the network might have to be adjusted to maintain the halo of non*detection sampling locations. This resulted in frequent review of the sampling network, and sampling stations were moved from the low intensity to high intensity sampling schedule as tracer was detected near the margins of !.he high intensity sampling network.
4.7.4 Analysis Schedule Samples were typically shipped from the Site on the sample collection day or the neXl day to accommodate next day delivery. Primary samples (both carbon and water) were analyzed within five working days after receipt. Water samples analyzed because of tracer detections in the associated carbon samplers were analyzed within five working days following the carbon analyses. Results were communicated (0 both Ozark Underground Laboratory (OULl and GZA project management for review of the detections and consideration of whether or not the sampling network should be modified.
4.8 ADI)ITlONAL GEOPHYSICAL TESTING TO EVALUATE FLOW PATHS In addition to the downhole geophysical testing described in Section 4.2.4. a series of geophysical surveys was conducted to assess the depth to bedrock in certain areas of the Site and to identify the potential presence of preferential groundwater flow paths along utility trenches cut into bedrock. The major findings of the surveys are graphically shown on Figure 1.3.
Under the oversigbt of GZA, AGS conducted surface geophysical surveys to assess depth to bedrock within the IP2-TY, along the North side of IP2-Turbine Generator Building (TB),
within the lP3* TV and along the OCA access road on the southern side of the Protected Area.
AGS used ground penetrating radar (GPR) and electromagnetic (EM) survey 42
equipment to complete the surveys. The survey reports are attached in Appendix O. The results of !.he surveys indicate that bedrock is fairly shallow beneath the areas investigated, except for the areas along the Hudson River where the depth to bedrock increases.
Specifically, the foUowing work was completed:
A GPR survey was conducted to assess depth to bedrock and potential utilily trenches cut into bedrock in the fP3-TV.
A GPR survey was conducted to assess the potential for contaminants to entcr growldwater through leaking stonnwater pipes (E-Series) and flow with groundwater towards the Hudson River within utility trenches cut into rock along the DCA access road on the South side of the Protected Area, and to identifY depth to bedrock and any utility trenches cut into rock along this roadway.
In order to assess the presence of subsurface utility trenches to provide preferential pathways for contaminated groundwater to flow to the North, thus accounting for the impacts to groundwater observed in monitoring well MW-48 and MW-38, AGS perfonned a geophysical survey consisting of a seismic refraction survey. GPR survey. and an EM survey to provide information on bedrock topography on the southern side of the Site between the Protected Area and the southern warehouse.
In addition, several utilities were identified using EM survey techniques. However.
no infonnation regarding the nature of the backfill along the utilities could be discerned from the geophysicaJ information.
The findings of the geophysical survey work are discussed in Section 6.0.
43
5.0 LABORATORY TESTING Entergy and GZA arranged for. and managed. the analyses of groundwater samples.
Berween October 2005 and the end of September 2007. over 700 samples were analyzed for radiological contaminants, and, as pan of the tracer test, nearly 4.400 samples were analyzed for Fluorescein. In addition, a limited number of samples were ana1yzed for selected water quality parameters.
This section describes the respective testing programs as well as some of the Quality Assurance/Quality Control (QNQC) procedures used to assess the validity of the data 5.1 RADIOLOGICAL Enterb'Y and GZA personnel both collected groundwater samples for radiological analysis from existing and newly installed wells berween October 2005 and September 2007.
Groundwater samples were sent by Entergy personnel via chain of custody to outside laboratories for analysis of select parameters including Tritium, Strontium, gamma emitters (including Cesium, and Cobalt), and Nickel21
- Samples were analyzed at the following labomtories: IPEC, Teledyne Brown Engineering. lnc., located at 2508 Quality Lane, Knoxville, Tennessee; Areva NP. Inc. located at 29 Research Drive, Westboro, Massachusetts; James A Fitzpatrick, NPP Environmental Laboratory, located at 268 Lake Road, Lycoming, New York; and General Engineering Laboratories located at 2040 Savage Road, Charleston, South Carolina The results of the groundwater analyses are summarized in Table 5.1. Note that the sample nomenclature for groundwater anaJytical data collected after May 2007 are provided in the figures, however, location nomenclature prior to May 2007 may differ" due to subsequent casing reference point upgrades.
5.1.1 Hydrogeologic Site Investigation Analytical Data Groundwater samples were typically analyzed for the tollowing: Tritium by EPA Method 906; Strontium by EPA Method 905; and gamma emitters (including Cesium and Cobalt).
In addition, transuranics and Nickel (as well as other "hard to detect" radio nuclides) were also analyzed in specific instances. as appropriate.
Quality control criteria utilized during this investigation included the following as appropriate: laboratory blanks; field duplicates; laboratory duplicates; laboratory control samples; matrix spikes and matrix spike duplicates; initial and continuing calibrations; instrument tuning; internal standards; and regulatory split samples.
Jj Trillum lind Strontium were the primary mdionuclides focused on during the current work pursuant to source identillcution. groundwater floW analysis IUId contaminant plume delineation. Radionuclidcs other than Tritium and Strontium also exist to 8 limited exttnt and are fully addressed within the come:.;t of the Unit 2 Trilium und Unit I Strontium discussions.
~l See SC';clion 4,3.4. Note, however: \\) High priority and fast truck sampling preceded casing elevation surveys and vuult instaUation in several cases" 2) low flow sampling within a well ~recn resulted in collection of samples 81 depths differing from the well nomenclature, and 3) reinstallation of Wltterlo() mul!ilcvcl wells to upgrade packer assemblies. In addition. snmplc intervals arc designated by depth from top of casing.
44
An overall evaluation of the data indicates that the sample handling, shipment and analytical procedures have been complied with, and the analytical results should be useable. However, during one time period (August nod September 2006), Strontium analytical results from Teledyne Brown Engineering, lnc. were as much as an order of magnitude different than split samples analyzed by the NRC and the NYSDOH.
(Following verification of this information, the laboratory was dropped from the investigation program.)
Therefore, that sample set was not utilized as part of the investigation.
Data Collectioll and Tracking The data collection and data tracking phase included the following:
Preparing all sample bottle labels and chain-of-custody forms; Documenting all required data in field log books and field logs; Performing data entry of the sampling information into Entergy's database system; and Quality assurance/quality control reviews of all data entry.
Laboratory Analysis The laboratory analysis phase included the following:
Regular communication between the laboratory and the project laboratory dala manager; Reviewing the laboratory's sample receipt acknowledgement fonn; Docwnenting the project's progress in Entergy's database system; and Laboratory preparation of the Electronic Data Deliverable (EDD).
Data Loadillg The data loading phase included the following:
Loading all EDDs into the database; Resolving any data loading issues; Creating a post-load report for content review; and Notifying the project team when EDDs were available.
Data V;sualizaJ;on and Analysis The data visualization and analysis phase included the initial data review by the project team and the production of data queries and draft reports to interpret the data This phase was accomplished through the use of query tools and prefonnaned reports in tbe dalabase.
45
5.2 ORGANIC TRACER Sampling for the tracer was based on both activated carbon samplers and on grab water samples.
All analyses were conducted using a Shimadzu R.F5301 fluorescence spectrophotometer operated under a synchronous scan protocol. Details of the analytical approach are presented in the Ozark Underground Laboratory (OUL) procedures and criteria document (Appendix Pl.
5.3 WATER QUALITY PARAMETERS Groundwater samples were collected from monitoring wells MW~38, MW48-23. and MW-48-38 and also from the Discharge Canal and Hudson River. The groundwater was collected as a grab sample using low flow sampling techniques. The surface water samples from the top of the water column were collected using bailers. The samples were collected at high and low tides. Groundwater samples were also collected at mid tide23.
The samples were sent under chain-of-custody procedures to Life Science Laboratories, Inc.,
BrittonJ:ield Parkway, Suite 200, East Syracuse, NY 13057.
The samples were analyzed for Bicarbonate Alkalinity (as CaCO,) under EPA Method M2320; Iron, Magnesium, Sodium, and Calcium lmder EPA Method 60 10; and Sulfate and Chloride under EPA Method E300.
lJ Sample nomenclature wa,> as fnllnws: Mnnitoring Location Name-Depth Interval (if applicable). Tide Interval (HcHigh, M" Mid, I.- Low) and replicate number nrapplieable).
46
6.0 HYDROGEOLOGIC SETIING This section describes the hydrogeologic setting at £PEC. OUT description is based on 8 literature search and the findings of our field investigation program. The hydrogeology is described in reference to the two components of an unconfined aquifer found at £PEe; overburden and bedrock.
Both the overburden (in select areas) and bedrock are groundwater-bearing zones which are monitored at the Site. Refer to Section 4.0 for a summary of the groundwater monitoring system.
6.1 REGIONAL SETIING The surface topography in tlle region of the Site slopes downward relatively steeply towards the Hudson River and is characterized by ground surface elevations ranging between approximately 10 and approximately 140 feet above the National Geodetic Vertical Datum of 1929 (NGVD 29). Refer to Figures \\.3 and 3.2 for Site and regional topographical maps, The Hudson River is a tidally influenced estuary in the vicinity of the Site, generally experiencing two high tides and two low tides daily. Near high tide,the river experiences a flood current running North. Near low tide, the river experiences an ebb current flowing South.
Surface water elevations of the Hudson River as measured at Peekskill, NY, approximately two miles North of the Site, from October 20, 2005 through May 8, 2006 have ranged from *1.31 feet to 3.26 feet NGVD 29. On*Site measurements indicate that me Hudson River elevations vary between -1.1 feet to 3.8 feet NGVO 29.
Other surface water features include the cooling water Discharge Canal with a mean surface water elevation of approximately 1.7 feet above the Hudson River. The Discharge Canal is shown on Figure 1.3. The Discharge Canal conveys up to 1.76 million gallons per minute (MOM) from Units 2 and 3, discharging to the Hudson River. As shown on cross..
sections A-A' and B*S' on Figure 1.3, the walls of the canal are constructed of low structural concrete, However, the current condition and thickness of the canal bottom is variable and appears to range from a O.5*foOHhick mud slab in the lP2 area (based on construction drawings) to a bedrock boltom in the lPl area.
Stonnwater at developed portions of the region and Site is directed rowards and collected in catch basins and discharged to surface water bodies. Storm water discharges from the Site are routed to the cooling water Discbarge Cana124, the Hudson River, or the groundwater regime through leaks from the storm system.
6.2 GROUNDWATER RECHARGE Groundwater recharge at and near the Site is limited to precipitation. That is, there is no significant artificial recharge or irrigation in the area. Precipitation in the vicinity of the 24 There W'c stomlw&tcr outfalJs that discharge directly to the Iludsotl Riv~t.
47
Site is approximately 36 inches per yeals. Recognizing that a portion of precipitation is lost to evaporation, transpiration, and run-off. direct recharge to an aquifer was estimated.
Large scale modeling performed by the USGS for Westchester County, Ny26, suggests that groundwater recharge to glacial till-covered bedrock hills, typical of the conditions near Indian Point, ranges from 3.6 to 7.5 inches per year with an average of 5.5 inches per year.
Our experience in a similar hydrogeologic setting27 found higher natural recharge rates, averaging approximately 10 inches per year. Considering all available information, we believe recharge at the Site is between 1110 and 1/3 of precipitation.
Based on our evaluation, we estimate recharge on and up-gradient of the Site is approximately 10 inches/year".
Note that for the purposes of this study (as opposed to water supply evaluations), it is conservative to use high estimates for recharge.
6.3 GROUNDWATER DISCHARGE Groundwater flows from areas of higher heads to areas of lower heads along the path of least resistance. At the Site, discharge from the groundwater occurs into the Discharge Canal, the Hudson River. and to system underdrains. As evidenced by Site groundwater contours, groundwater discharge is not uniform along the river or to the Discharge CanaL 111at is, the aquifer in areas of the Site with higher transmissivities (lower resistance to flow) will discharge more water than other areas. Similarly, the water table fluctuates seasonally (due to long tenn changes in average recharge rates) and locally during rainfall events and periods of snow melt. Consequently, groundwater discharge is not constant in time. Additionally, changes in the river elevation cause additional short term variations in discharge rates.
The Hudson River is the regional sink in the area. As such, groundwater from the upland areas to either side of the river valley flow towards and discharge to the river under ambient conditions, see Figure 6.10. Groundwater from IPEC does not flow under the river to the other side (e.g., to Rockland County) under ambient conditions.
- Further, because of the hydraulic properties of the bedrock, as well as the size of the Hudson River in this area, there is no reason to believe that pumping or injection (non-ambient conditions) could induce such flows.
n This prc;:Cipitution value is !t 10 year average of datil IIvailable from the on-Sitt meteorological station.
26 USGS. Wat~r Use, Ground-Water Recharge and Availability. and Quality of Water in the Greenwich Area, Fairfield County. Co nn~ct icut and Wc:stchester County. New York. 2000-2002.
27 Calibrated Groundwater Modcl, Central Landfill Super Fund Site, Johnston Rhode Island. Junc-Z006 28 Areal Rccharge varies temporarily and spatially. The average of 10 inches per year is an estimatcd w(l\\crshcd-widc, long h.:rm average. The dcvelopment at the Site induces additional runoff. We believe that this potential decrcase in areal recharge is otfsel by recharge from extiltralion of leaky storrnwatcr systems. As discussed in Section 6.7. this appears to be the case.
48
GROUNDWATER FLOW BELOW AND INTO HUDSON RIVER Foundation drains at three structures (see Section 6.7) intercept groundwater (see Figure 1.3).
This water is conveyed, via gravity flow andlor pumping, to the Discharge Canal, creating local depression in lhe water table and a flanening of hydraulic gradients downgradient of the structure. With these conditions noted, over a period of months the rate of groundwater discharge to the river at IPEC is continuous and fairly constant. Discussions on the rate of discharge are provided in Section 6.7.
6.4 GEOLOGY This section describes the geology of the Site and region. It is based upon a literature search and the results of our investigations.
Figure 6.2 portrays the regional bedrock geology. The narrative is organized to convey the role of geologic and tectonic processes in creating the mechanisms by which groundwater flows through the Site29.
Findings support our Conceptual Site Model (CSM) and indicate tllat the bedrock at the Site is characterized by sufficiently interconnected small bedrock fractures to allow the hydrogeologic system to function and be modeled as a non-homogeneous, anisotropic, porous media.
6.4.1 Overburden Geology The Lower Hudson Valley has been subjected to repeated glacial advance and retreat, creating a typical glacial morphology of main and tributary valleys and bedrock ledges.
The glaciers have controlled the deposition of unconsolidated deposits in the region, although these are absent locally due to erosion and excavation. Glacial till lies directly on the bedrock surface and is generally less than 10 reet thick, although it is locally thicker against steep North-facing bedrock slopes. The till is typically unstratified and
- 9 The Inwood Marble. which predominates at the Site. is a crystalline metamorphic rock type. As ~ ll ch. it has a very low primlU')' porosity (i.e.* water does not now through the intllct rock itself, bUl is confined 10 Ihl! fractufe§ in Ihe rock.
49
poorly sorted. Locally, it consists of a silty, fine-to medium-grained, brown, sandy matrix containing fine gravel to boulder-size bedrock fragments. Fluvial and lacustrine glaciaJ deposits Occur in valley bottoms and valley waUs. The glacio-fluvial deposits are typically medium to coarse sand and gravel with minor silt. The lacustrine deposits are flOely laminated and varved clays fining upwards to fine-to medium-grained sand ~ and the fluvial/deltaic sediments are mixtures of coarser sands and gravels and finer sands to clays.
Recent deposits are essentially flood plain and marsh deposirs along the Hudson River, its tributaries, and sma)] enclosed drainage basins.
Overburden geology at the Site is limited to a layer ranging from ground surtace to between 3.5 and 59 feet below ground surface (bgs). wilh thicknesses generally increasing towards the Hudson River. Overburden materials are dominated by anthropogenic fiJI (borings MW*41, -49, *52, as well as the upper 20 reet of -39. -48, -61, -62, -63,
- 66 and 67). Soil-based fIll materials at the Site consist primarily of silty clay, sand and gravel mixtures (Le., regraded/transported on-sile glacial till) or graveUcobblelboulder-size blast rock. In areas adjacent to structures excavated into bedrock, the fill occurs as concrete, compacted granular soils, and blast rock fijI. Native materials occur as open areas of glacial till overlying bedrock. or silty clays. organic silt and clay, and sandy material overlain by granular fill. A 20- to 50-foot-thick sequence of river sediments (organic silts) is found along the Hudson River above bedrock in borings MW-38, -48, *61. -62, -63. -66 and 67 The approx:imate location of natural materials is shown on Figure 6.3.
6.4.2 Bedrock Geology The geology of the Site has been investigated and reported by Dames & Moore (1975) prior to this program. Figures 6.2 and 6.4 show the bedrock geology of the region and the Site. respectively. The current investigations have added substantial detail to this assessment which shows that the bedrock beneath the ite-is considerably fractured and contains sufficient interconnectivity to support groundwater flow, at the scale of the Site. as flow through a non-homogeneous, anisotropic. porous media.
The Site is located in a complex of Cambro-Ordovician rocks represented by the Manhattan Formation and Inwood Marble Formation in angular unconformity. The Site lies predominantly upon the lnwood Marble Formation as an angular unconformity with the Manhattan Formation. The oldest rock is the Inwood Formation, which was derived from deposition of carbonate materials in a shallow inland sea during the Cambrian through the early Ordovician period. The Manhanan Formation is interpreted to post-date the Middle Ordovician regional unconformity witb the Inwood Marble and represents sediments derived from continental or volcanic island materiaJs in deeper waters.
During the Ordovician period, an island arc system consisting of a series of volcanic islands appeared off the coast of what is currently North America as a subduction zone developed in response to oceanic crust colliding with continental crust. The presence of the volcanic island arc system resulted in interlayering of volcanic material with the sedimentary rocks of the Inwood Marble and Manhattan Formations.
As continued subduction occurred and continental land mass began to collide with continental North America during the Taconic and Acadian Orogenies, the rocks of the Inwood Marble 50
Formation and the Manhattan Formation underwent substantial metamorphism and defonnation.
The Inwood Marble is a relatively pure carbonate rock of dolomitic andlor calcic mineralogy with silica rich zones. The rock tends to be coarsely sacherroidal with remnant foliation and intercalated mica schist. The color and crystalline texture vary from place to place due to the various levels of metamorphism; the color is typically white to blue grey.
The metamorphic grade is locally elevated due to minor intrusions. The common minerals are calcite, dolomite, muscovite, quartz, pyrite and microcline. The Manhattan Formation is represented on the Site by two distinct members. The lower member is an assemblage of schist, schistose gneiss and amphibolites intercaJated with marble, white quartzite and fine*grained metapelite. The marble bearing lower member ot' the Manhattan Formation likely represents transition ITom a shallow carbonate sea to deeper water sedimentation and maybe the equivalent to the Balmville Limestone which occurs in Dutchess CountyJo.
The middle member is garnet rich mica schist. The upper member consists of biotite*
muscovite mica schist with quartz-feldspar laminae.
The original sediments have undergone repeated intense phases of burial.
metamorphism, uplift, folding and faulting due to: three phases of continental collision (the Taconic, Acadian, and Alleghanian); continental rifting as the present Atlantic Ocean began to fonn in the Mesozoic; erosion/uplift; and recent glacial rebound. All of these processes have resulted in the presence of fractures that affect the hydraulic properties of the material. The main deformational events are represented by multiple superimposed textures and structures including faults. healed breccias, crenulations. foliation slips, micro-faults. and continuous/truncated jOints/fractures. The frrst phase of fold defonnation (F1) was essentially ductile and produced isoclinal folds contemporaneous with the most intense metamorphism. h was at this time that the dominant foliation likely developed along Original bedding planes. The cooling period following this phase marks the onset of regional brittle faulting and development of fractures along the bedding planes. The second phase of folding (F2) is characterized by flexural slip, indicative of brittle conditions. producing distinct fault and fracture orientations: a conjugate system nonnal to the fo liation; West-Northwest and North-South conjugate strike-slip faults; Northwest faults and fractures parallel to the direction of extension; and lhrust and extension fractures parallel to the foliation.
The Cortlandt Complex (a large igneous intrusion located East of the Site) was intruded during the F2 phase. The post-Cortlandt dislocations were associated with a third phase of folding (FJ) causing a mutual rotation of the structural elements producing a complex of conjugate features with a wide range of orientations as described by Dames & Moore and found during our study.
On the Site, the regional features are represented by North-Northeast and North-Northwest trending faults in cross-cutting relationshjps, representing a conj ugate system with a North-South regional compression direction. The final tectonic event was associated with a shear system oriented North-East, reactivating movement aJong Nonheast-trending faults and minor North-Northeast to North-Northwest-trending faults. In addition to these major events, there has been minor
,0 [n VemtMI. thj~ UJiIt is equivaleM to the Whipple MfU'blc.
51
nonnal movement on North-South and Northwest-trending faults associated with continental rifting during the Mesozoic Era.
Finally. post-deformational uplift and glacial rebound have resulted in a series of fractures related to expansion. after the rock mass/ice load was removed during erosion and glaciaJ retreat. These manifest themselves as semi*sinuous or lmdulating horizontal relief fractures.
6.4.3 Groundwater in Bedrock in metamorphic bedrock such as the marble present at the Site, groundwater occurs and migrates in open spaces such as fractures. These void spaces are termed secondary porosity. The primary porosity consists of void spaces within the rock matrix. itself.
The Inwood Marble has a very low primary porosity which does not contribute to the flow or storage of significant volumes of water. Therefore, the presence of fractures and faults ultimately detennines the hydraulic conductivity of the bedrock mass.
The fracture aperture spacing and the degree of fracture interconnectivity are dominant variables in how groundwater flows through the fractured bedrock environment. Groundwater flows from areas of higher hydraulic head to areas of lower hydraulic head aJong fractures providing the least resistance. If the structure of the rock is dominated by fractures and foliations ofa single orientation. then groundwater flow will be along this orientation towards areas of lower hydraulic head.
Also, if fractures are separated by large distances and not interconnected, groundwater will flow in a relatively limited number of fractures and flow will be governed by the orientation of local structures within the rock. This may result in groundwater flow occurring along paths that may not be reflected in topography. However, if there are abundant sets of fractures of differing orientations relatively close together and interconnected, groundwater flow will typically mimic topography.
GZA found no evidences of solution features (i.e.* cavities, voids). Such features (if present) can control the direction of groundwater flow. Carbonate rocks have relatively high solubility under certain ambient surface conditions.
This can result in solution cavities and caves known as karst systems.
In these situations, groundwater can flow predominantly along open cavities and result in preferential pathways. Our assessment of over 3,200 linear feet of rock core and 2,950 linear feet of borehole geophysical logs found no evidence of any large scale solution features. Minor, discontinuous vugs (smaJI unt11led cavities) and voids were observed primarily along partially heaJed fractures with euhedral calcite crystals growing into fractures. This evidence suggests that prior to denudation.
resulting in exposure of the rocks to the current elevations; hydrothermal fluids were percolating through open fractures. Mineralization occurred aJong the ITacture planes resuJting in a significant number of healed fractures observed in the rock. In some cases.
the fractures were panially healed, resulting in the occurrence of vugs in some of the more brecciated lones. The presence of calcite deposition in fractures supports our observations that solution features are not prevalent at the Site. That is, open fractures are due to tectonic forces. that carbonate is precipitating within the fractures, and no large solution cavity process is occurring.
Since earlier conceptual models tor the Site hypothesized that groundwater flow would be to the South-Southeast along the original F I foliation and fracture sets, we 52
perfonned a detailed structural analysis of the bedrock to assess wbether groundwater flow would be dominated by discrete fracture flow or would behave more in accordance with flow through porous media This analysis had implications relative to on-Site contaminant migration and the potential for off-SHe migration via dominant fracture sets.
6.4.4 Regional Scale Geo.tructurc GZA assessed regional frac.ture patterns presented in the Dames & Moore (1975) report as a photo lineament analysis (Figure 6.5). On the regional scale of the lineament analysis: there are three sets of intersecting fracture orientations.
The major strike orientations wilhin a 15 mile radius of the Site indicated a Northeast, North, and East-West trend. A review of the major tributaries to the Hudson River indicates the drainage panem is predominantly aligned with similar orientations and generally structurally controlled.
6.4.5 Site Scale Geostructure On a Site scale, aZA projected the fracture plane orientations calculated. from the borehole geophysical data onto one elevation (elevation 10 feet) to create a Site lineament analysis (Figure 6.6). Assessment of the more permeable fractures on lhis projection showed thai fractures were oriented consistent with the regional assessment (Northeast.
North and East-West), and that fracture orientations intersect one another. In addition, our Site scale lineament analysis showed a number of Northwest orientated fractures located between Unit I and Unit 2 in the area where the Unit I and Unit 2 plumes commingle.
Evaluation of the preconstruct ion bedrock topography a150 indicated that this was a low point in the bedrock surface. Low points in marble bedrock surfaces are usually associated with areas of higher fractwe density or faulting as these wouJd be areas mOre prone to weathering, erosion and glacial gouging. This presents further evidence for a zone of higher transmissivity.
Based upon the regional and Site scale lineament analyses. it was apparent that the multiple fracture orientations result in intersections of fracture planes. However. more detailed analysis was required. Therefore, aZA assessed the individual rock cores and fracture orientations calculated from the borehole geophysical analysis.
6.4.6 Borehole Scale Geostructure Twenty-three of the forty-seven boreholes were evaluated using acoustical televiewer (A TV) and optical televiewer COTV) borehole logging techniques by Geophysical Applications, Inc. The ATV data establishes naturally occurring jointlfracture dip angles and planer dip directions for planer features intersecting a borehole.
The apparent joint/fracture orientations and depths were input into a stereographic framework using DIPS software developed by RoeSeienee, Inc. of Toronto, Canada, after correction from magnetic North to true North. The srereographic projections are a southern hemispheric view and are equal-angle based.. The program presents the jointlfracrure dip and dip direction in a tabular fonnal wilh customizing options, and allows joint/fracture set selection to establish groups of domains and families of geostructural data.
53
The 4,623 data points from the 23 boreholes were input into the DIPS program. The polar projections for all the boreholes are presented as Figure 6.7. In Our opinion, these data show three dominant, apparent, conjugate sets of fractures striking to the Northeast*Southwest, East*WeSI, and North*South. The majority of lhe dip angles range consistently between 30 and 70 degrees for each major orientation. In addition, there are many horizontal and vertical fractures. The orientations of the fractures, the conjugate sets of fractures, and the presence of vertical and horizontal fractures all support a high degree of interconnectivity.
The database also contains columns showing the depth of the individual joint/fractures and apparent vertical continuous spacin~l. In each borehole, three average values of apparent vertical joint set spacing for depths between 0-30 feet,30-100 feet, and depths grealer than 100 feet were calculated and summarized in the following table.
No significant differences in joint spacing with depth were found.
AVERAGE APPARENT JOINT SPACING. FT Depth Below top of tbe rock Depth Below top of tbe rock Borehole I)..JOft JOft-IOOft
>Ioon Borehole I)..JOft JOn-100ft
>IOOfi MW*30 0.53 0.64 MW*55 0.48 0.47 MW*3 1 1.46 0.63 MW*56 0.32 MW*32 0.36 0.39 MW* 57 0.55 0.30 MW*34 0.72 MW* 58 0.32 0.66 MW*35 0.80 MW*59 0.35 0.41 MW*39 0.66 0.67 MW*60 1.38 0.83 0.59 MW-40 0.37
- 1. 11 1.69 MW*62 0.49 0.64 MW*51 0.3 7 0.88 0.84 MW*63 0.35 0.44 MW*52 0.45 0.58 0.89 MW*65 1.26 MW*53 0.71 MW*66 0.75 0.59 MW*54 0.47 0.58 0.39 MW* 67 0.47 0.59 0.54 RW*1 2.22 1.71 AVERAGE APPARENT JOINT SPACING Joint spacing is a significant parameter in assessing flow in a fractured rock and assessing the validity of using an equivalent porous media flow model. The spacing of joints was determined by direct measurement from rock core samples or from ATV data in 22 boreholes, and is presented in a database (Appendix Q). These data indicate an apparentjointlfracture spacing between 0.3 and 2.2 teet, with an average orO.7 feet.
Based upon the assessment described above, the data suggest that tbe bedrock aquifer can be visualized as a series of polygonal blocks separated by interconnected fractures. This geometry is graphically portrayed by a series of seven apparent fracture JI Apparenl venical spaclns is the distance: bt::lween Jolnlllhtctures along the wrtlclllline Oflhc borehole.
54
profiles designated A-A' through 0-0' presented on Figure 6_9; prof1Je locations are presented in Figure 6.S. The profiles show the orientation and potential connectivity afthe geostructure if the A TV borehole measured planes extended for 1,000 feet (500 feet on either side of ll1e borehole). The jointJfracture lines represent the trace of the plane projected onto a vertical profile. Additional illustrations of the fracture orientations in three dimensions are presented in Section 6.4.8.
6.4.7 Geologic Faults The groWldwater flow pattern and thus contaminant transport can be further influenced by the presence of faults. These taults can either act as barriers or conduits to flow depending on the presence of clay-rich fault gouge. Rock core samples revealed significant clay fault gouge zones that generally ranged between 0.2 and 0.7 vertical feet thick at borehole locations MW-3\\, -50, -54, -60, and -6\\. These zones were encountered at depths ranging between 39 and 200 feet below existing grades. The dip angles were measured by the A TV methods and ranged between 49 and 82 degrees at locations MW-31, MW-54, and MW-60, with dip directions toward the East (MW-54) and the Southeast (MW-3l and MW*60). No ATV measurements were conducted at MW-50 or MW-61.
At MW-61, no core was recovered between 156 feet bgs and 221 feet bgs.
Collection of spUt spoon samples in this interval verified the presence of a clay-filled fault gouge. This boring likely intersected a steeply dipping North-South trending fault. The presence of this fault is consistent with faults previously mapped by Dames & Moore (1975). The near vertical orientation of the fault is funher supported by observations of bedrock core from locations MW-66, advanced within 8 feet of MW-61. No fault gouge was observed in this boring. A fracture zone was noted between 136 and 145 feet bgs and is characterized by low RQDs, however, this fracture zone did not exhibit clay fi lled fault gouge and was more consistent with tightly spaced fractures.
Because the fault extends to the top of the bedrock, the question arises as to why we did not observe the fault zone above 156 feet bgs at MW-61. This is due to the geometry of the fault. The fault zone is sub-vertical, i.e. less than 90 degrees, but also may vary in orientation with depth. As the boring was advanced deeper into the bedrock~ it intersected the fault zone at 156 feet bgs. The boring continued within the fault. in a near vertical portion of the fault, to the termination of the boring.
Furthemlore, the rock core samples revealed several fracture zones ranging between appro~imately 0.5 feet and 110 feet thick. Significant zones of poor to no recovery are evident at MW-50, MW*61 and MW-66: boring MW*50 and MW-S4 were aligned along or near the trace of historic faults mapped by Dames & Moore (1975). MW-49 and MW-61, may be aligned along the extension of a historic fault mapped by Dames & Moore (1975). The poorrecovery observed at MW-50 and MW-61 is indicative of clay gouge that was washed out during the drilling process (which is consistent with, but not fully verified by, the split spoon samples containing clay, recovered in these borings). We further note the presence of this fault zone does not appear to materially alter groundwater flow directions or contaminant migration towards the Hudson River.
Figure 6.4 portrays faults mapped on the Site by Danles & Moore (1975). There arc three major groups of faults with associated fractures identified at and in the vici nity of 55
the Site. These groups have azimuths of approximately 45, 75, and 290 degrees. The East to N75E faults consist of conjugate faults where the sinistral set strikes West to N70W dipping southward, and the dextral set strikes East to N75E dipping southward. These faults are most often offset or truncated by younger faults. West striking faults in the Inwood Fonnation are typically characterized by breccias which have been healed by a re~
crystallized calcite cement.
An additional fault or fracture zone appears (not shown on Figure 6.4) to extend from the Hudson River Southwest between Units I and 2, as expressed by fracture orientations and a low in the preconstruction bedrock contours. This appears be a zone of higher transmissivity as indicated by inflections in groundwater contours. tidal response measurements. and the shape of the contaminant plume.
6.4.8 Bedrock Structure Visualization In order to aid in the visualization of the role bedrock structure plays on groundwater flow as well as show the apparent interconnectivity at the Site, GZA imported data collected throughout the various phases of investigation into a 3-dimensional visualization model. The Environmental Visualization Software (EVS) software suite.
created by CTech Development Corporation, was the primary software application used for the development of this model. This software package provides real-time model rendering, animation/Oyover capabilities, database and GIS interface utilities, and numerous image output options. EVS also provides the ability to interpolate variably spaced datasets via kriging. an established geostatistica1 technique.
The EVS kriging process selects an optimal semi-variogram model for each kriged dataset in order to estimate unknown values, and provides statistical confidence Ibr estimated values. The results of these analyses can then be rendered across three dimensions (x. y and z) to provide a spatiaJly referenced visualization model.
GZA incorporated the borehole geophysical data provided by GA, the packer testing results, and the USGS evaluation of the HPFM data into the 3-dimensional visualization model. Our goal was to illustrate transmissive tracture locations. For many of the zones identified as transmissive, several fractures likely contribute to the estimated transmissIvity.
In these cases. a percentage of the estimated zone transmissivity was allocated to each contributing fracture based On the HPFM results and ATV/OTV logs.
In addition, multiple fractures in close proximity and exhibiting similar planar characteristics were combined to present a single planar feature to avoid redundancy in the model. The fracture data set was imported into the 3-dimensional visualization model intact.
Figures 6.10 through 6.14 present the locations of transmissive fractures within each boring. Fractures are represented as disks with 50 foot radii. A single disk represents the strike direction and dip angle of a transmissive fracture feature. Fracture disks are aJso color coded to reflect the assigned transmissivity value. Boring designations and locations highlighted in yellow indicate the borings for wbich geophysical and transmissivity information was available. Boring designations and locations highlighted in white are lacking geophysical data; therefore. fractures are not presented. The transmissive fnlcture data set was divided into low transmissive (0.02 - 10 Il'/day, Figure 6.10), moderate 56
transmissive (10 - 50 Il'/day, Figure 6.11) and high transmissive (50 - 250 fi'/day, Figure 6.12) subsets. While there are limited geophysical data for borings located to the South and East of the Site, the available data do indicate that there appears to be a zone composed of more trWlSmissive fractures within the center of the Site. This observation coincides with a low in the bedrock as elucidated by preconstruct ion bedrock contours (Figure 6.4).
This historic depression may be the result of weathered or fractured bedrock being susceptible to glacial advance and retreat, indicating the potential for a fault to be present in this area. This is consistent with the observation of a lineament West of Unit 2 toward the Hudson River discussed above.
Figure 6.13 represents the same fracture data set, hut with tIle fracture disk radius extended to 250 feel. A horizontal cutting plane has been extended across the Site at elevation 10 feet, identifying the strike direction of each fracture as it intersects the plane.
For a selected diameter of disk, the width of the strike line has significance, A shallow dipping disk would have more contact with the horizontal cutting plane than a steeply dipping disk. Accordingly. a wider strike line indicates a fracture strike direction with a shallower dip angle. The East-West lineament is clearly visible in mis figure. aligned approximately from Unit 2 toward the Hudson River. and comprised of moderate and high transmissive fracrures. Figure 6.14 represents the same horizontal slice concept; bowever, the slice plane is now placed at elevation -100 feet.
There are no high transmissive fractures intersected at this elevation, indicating high transmissive fractures are more predominant at shallow depths, This is consistent with Figure 6.13, the Conceptual Site Model, hydraulic conductivity tests and previous repons (Tectonics, 2004). Because we observed no decrease in fracture spacing with depth (see Section 6.4.6), this suggests the hydraulic aperture of fractures decreases with depth.
While there are some locaJizeci trends in fracture strike direction, there is an abundance or intersecting fractures on a Site-wide scale occurring at all elevations.
In addition, the fracture disk component of the 3-dimensional visualization model has been reviewed to identify potential fracture connections on a borehole-la-borehole scale.
No significant interconnections were identified. These observations suggest that bedrock is highly fragmented on a Site-wide scale, high transmissive fractures are not continuous across IPEe. and groundwater now through the Site may be modeled as now through a non-homogeneous, anisotropic, porous media.
6.4.9 Bedrock Surface Elevations and Preferential Groundwater Flow Pathways The results of the surface geophysical surveys are portrayed on Figure 1.3, The geophysical survey identified apparent bedrock at depths of between 2 and 18 feet below ground surface (bgs) within the lP2-TY. A depression in the bedrock surface exists in the vicinity of monitoring well MW-ill. Bedrock in the depression was tound at a depth of 16 to 18 feet bgs. Along the North side of the IP2-TB, apparent depth to bedrock was approximately 8 io 12 feet bgs and only intermittent groundwater associated with rainfall events has been encotultered. This is likely the depth bedrock was cut in order to accommodate the service water lines. No discrete utility trenches were observed in the bedrock. Based upon the results of the geophysical survey it is more likely that bedrock was cut to a depth to accommodate deep subsurface utilities and potentially dewatering, 57
rather than install utiHties in individual trenches. On the eastern, western and southern sides of the Transformer yard. rock was encountered betweeo 2 feet and 7 feet bgs.
No groundwater was encountered in the overburden in these areas. However. groundwater was encountered in the backfill found along the western wall of the Discharge Canal, which forms the eastern boundary of the 1P2-TY.
Within the IP3*TY, the approximate depth to bedrock ranged between 7.5 and 10.5 feet bgs. Generally the northern and southern ends of the survey area had the deepest and shallowest depths to bedrock, respectively. Again, the surveys did not exhibit evidence of individual utility trenches cut into bedrock. No groundwater was observed in overburden within borings advanced within the lP3-TY.
To assess the potential for contaminants to entcr groundwater through leaking stormwater pipes (E-Series) and flow with groundwater towards the Hudson River within utility trenches cut into rock along the OCA access road on the South side of the Protected Area, tbe depth to bedrock and utility trenches cut into rock along this roadway was evaluated. The approximate depth to bedrock ranged between 8 and 16 feet bgs. Bedrock reflectors appeared to be less defined in this survey area compared to other areas at the Site. Many potential utilities were observed in the survey area, however it appears that one large bedrock trench was excavated to accommodate the utilities as well as the roadway.
The bedrock appeared to be deeper near the "delta gate" along the East side of the survey area, reaching an apparent depth of 16 feet bgs. Funher to the West the apparent bedrock surface was observed at a depth of approximately 8 feet bgs.
Seismic data col1ected around the warehouse on the South side of the Protected Area provided good subsurface infonnation to a depth of approximately 50 feet bgs.
In general, the apparent bedrock surface was found at depths of approximately ground surface on the East side of the survey area and sloped down to depths greater than 4S feet to the West. Near MW-48, the bedrock was located at 25 feet bgs. Topography of the bedrock interFace ranged from flat to highly variable over relatively short distances and there were a few locations where the bedrock interface "disappeared" or was located greater than 40 to 45 feet bgs. Over most of the area, the bedrock interface was more gradual and slightly undulating along the profile lines. In general, the depth to bedrock was greater then 20 feet across most of the survey area, indicating that subsurface utilities would not be cut into bedrock trenches.
6.S AQUIFER PROPERTIES Our investigations demonstrate that, for the purposes of evaluating groundwater flux, bedrock beneath the Site can be modeled as flow in porous media. Following are the hydraulic properties we assigned to our equivalent conceptual porous media model.
58
6.5.1 Hydraulic Conductivity Transmissiviry and hydraulic conductivitY2 data were collected as part of the hydrogeologic investigation in both the overburden and bedrock. The geometric mean of hydraulic conductivity in the overburden zone is 12.6 ftJday and the geometric mean in the bedrock is 0.27 ftJday. As indicated below, calculated hydraulic conductivities within the bedrock were found to be log-normally distributed.
alA used probability graphs to evaluate the statistical distribution of the bedrock bydraulic conductivity data. As shown on the following two graphs, the log-transf'ormed data better approximates a straight line. This indicates the log-transformed hydraulic conductivities are approximately normal and the hydraulic conductivity values are log-normal. This indicates that the geometric mean is a good approximation.
Probability Plot ot Bodrock Hydraulic Conductivity Data
.. L-____
~~_~
- 3.0
-2.0
_10 0.0 1 0 Norm,IOu,ollle STATISTICAL ANALYSIS OF HYDRAULIC CONDUCTIVITY MAGNITUDE n Transmissivity. as used here. is the property measured in the field and is thc product of ILIl equivalent hydrllulh:
conductivIty (K) lind the test interval.
59
Probability Plot of Natu~ll..og Transformed Bedrock Hydraulic Conductivity Dol *
- r-------------
Normal Quanll!.
STATISTICAL ANALYSIS OF HYDRAULIC CONDUCTIVITY MAGNITUDE (NATURAL LOG TRANSFORMED)
As shown below, GZA also developed a gr~h of depth versus transmissivity of bedrock. Ln viewing that graph, note that all USGS) measured transmissivities of greater than 100 if/day were found at depths or less than approximately 50 reet bgs.
1000 100 r-
~
~
~
S
~
t
=
C-0.1 0
100 15<1 200 25<1 Depth (rt)
TRANSMISSIVITY VS DEPTH lJ Transmissivilies shown were computed by the USGS rrom their heal pul~ flow meIer dllill which werc in agreement wilh our packer test data.
60
It should be noted that the hydraulic conductivity values art based on aquifer tests conducted at specific locations and limited hydraulic loading, and are therefore only representative of the aquifer immediately adjacent to the subject borehole.
GZA also conducted a Pumping Test which imposed a larger hydraulic stress over a larger portion of the aquifer. We believe this test provides us with the most reliable estimate of transmissivity of the bedrock in the area of the Pump Test. However! the area of influence of the Pwnp Test did not encompass the zone of higher hydraulic conductivity within the fracture zone between Units I and 2.
Depending on the methods used [0 evaluate the Pumping Test data. we eSLimate bedrock transmissivity values generally in the range of 30 ftl/day to 50 ft2/dat4* This suggests an average hydraulic conductivity of between 0.2 and 0.4 teetlday.
To further evaluate the vertical distribution of the hydraulic conductivity, we computed the geometric mean of measured values in the upper 40 feet of the aquifer and the geometric mean of all values measured below that depth. This calculation resulted in values of 0.4 feel per day for the upper forty feel and 0.2 feel per day for Ihe deeper aquifer.
6.5.2 Effective Porosity Evaluation of Pumping Test data also allows calculation of storativity.
Our Pumping Test results show the storativity of the bedrock aquifer is 0.0003.
(Note: overburden wells were not present within the cone of depression and, therefore.
storativity for the overburden could not be evaluated.)
Because the bedrock aquifer is unconfined and the primary porosity of the marble is, essentially. zero. the effective porosity of the bedrock can be as small as the storativity. However, due to dead-end fractures, the effective porosily is likely 10 be higher.
To evaluate the reasonableness of estimated properties, we used the cubic equation, as shown below, to estimate the hydraulic aperture and storativity of the fracture system:
Q p.gb' (b ) ah 121' 81 Where:
Q ~ volumetric flow (ft')
P. ~ density of waler (62.4lb/ft3) g ~ gravitational constant (32.2 Ills')
b ~ aperture opening (ftl J4 The Pumping Test indicated the transmissivity of the rock "'85 rairly isotropic. and o nl~' limited horizontal anisotropy was observed during the Pump Tests (~.g., in !.he dmwdown observations at monitoring well MW 53-1 20). At the scale or the. Pumping rest we believe there are sumciellt heterogeneities thnt the aquifer ean be considered to be a non*
homogeneous isotropic porous media.
61
J1 =
dynamic viscosity of water (0.0006733Ib/ft*s) w =
fracture,,;dth perpendicular to the flow direction (ft) ah
= groundwater gradient at From this, the concept ofan equivalent hydraulic conductivity has been developedJS:
Where:
K = p.gnb' 12J1 Variables are as previously defined, and; n =
number of open features per unit distance across the rock face Using a fracture spacing of one foot and an equivaJent bulk bydraulic conductivity of 0.27 fect per day (9 x 10" cm/sec), this calculation indicates a hydraulic aperture of approximately 75 microns. and a theoretical m.injmum porosity of 2.4 x 10-4.
The calculated porosity is in good agreement with estimates of storativity developed from Pumping rest data (Section 4.4.4) and tidal responses (Section 6.6).
Ln swnmary, the measured effective porosity of the bedrock aquifer is approximately 0.0003.
6.6 TIDAL INFLUENCES As discussed previously, the Hudson River, adjacent to the Site, rises and falls in response to ocean tides. Based on our measurements, this tidal variation (the numerical difference between low water and subsequent high water elevations) in 2006 ranged from approximately 1.4 feet to 4.3 feel, and averaged approximately 2.7 feet. This variation occurred between approximately elevation
- 1.5 feet to 3.7 feet NGVO 29 (i.e., the low tide elevations were typically above elevation -1.5 feet and the high tide elevations were typica1ly below elevation 3.7 feel). These data are in good agreement with published infonnation (see Section 6.1).
This natural variation produced measured effects that helped us better understand hydrogeologic infonnation obtained at the Site. One such em~ct is water level changes in monitoring wells at the Site. The observed changes demonstrate that the bedrock aquifer is significantly Iractured, and provided additional insight into aquifer properties.
Discharge of heated cooling water, in conjunction with tidal influences, produced a second effect: lcmporal temperaturc ehanges in groundwater in wells located ncar the Discharge
)j Snow. D.T. 1968. Rock Praclurc Spacings. O~ning.~. and Porosities. Journal or SOli Mechanics.. Found, Div. l>roe.
Am. SOC, ('I vii Ensrs.. v, 94, p. 73*91.
62
Canal. We used that information to help explain water quality data collected from two specific wells (MW-38 and MW-48, originally proposed as southern boundary monitoring wells), which did not initialJy conform with our Conceptual Site Model (see Section 6.6.2 below). These two effects are described in the following sections.
6.6.1 Groundwater Lt\\o'els The tidal-induced variations in surface water levels near the edge of the Site's aquifer (in the river and intake structures and Discharge Canal36) induced pressure changes in groundwater that were observed in monjtoring wells at the IPEe.
As a general statement, these responses (as anticipated) varied over time as sinusoidal-like curves that decreased in amplitude and exhibited greater lag time with increased distances from the river/Discharge Canal37, At the time of our tidal response study, there were 87 transducers installed in 49 monitoring wells. As shown on the following graph, we observed measurable hydraulic responses to tidal variations at 43 of these transducer locations. In viewing iliat graph. note distances are measured from the edge of the Hudson River. We chose this as the boundary because data suggests the river has more influence on pie7.ometric levels in the bedrock aquiter than do tbe intake structures and Discharge Canal. We further note that: I) 41 of the 44 pressure transducers within 400 feet of the Hudson responded to tidal variations;
- 2) at greater distances, tidal responses may have occurred but were too small to be recorded because of the accuracy of the transducers; and 3) the tidal response in wells located in the higher hydraulic conductivity area between Units 1 and 2 was more pronounced than in other areas. Cumulatively, these data demonstrate:
The aquifer is in strong hydraulic communication with the Hudson River~ and The bedrock aquifer is well-fractured.
- 6 The elevation of the water in the Discharge Canal riSeS and falls WIth the river elevation, but is maintained approximately 20 inches above the river level.
J Observed variations from this trend. in our opinion, arc consistent wilh nnticipmcd heterogeneities in an equivllli:nt pomus nll:lIin mndeL 63