United States Nuclear Regulatory Commission Official Hearing Exhibit Entergy Nuclear Operations, Inc.
In the Matter of:
(Indian Point Nuclear Generating Units 2 and 3) v...v-.'f\ REGV<..,,, ASLBP #: 07-858-03-LR-BD01
",~.::I 0",,, Docket #: 05000247 l 05000286 t
~
0 Exhibit #: ENT000464-00-BD01 Identified: 10/15/2012
>- ~
~ ~ Admitted: 10/15/2012 Withdrawn:
\
. ~
.. 01 Rejected:
Other:
Stricken: ENTOO0464 Submitted: March 30, 2012 CALCULATION CONTINUATION SHEET I SHEET No. 1 of 17 CALC. TITLE: Re-analysis of MACCS2 Models for IPEC
-Entergy CALC. NO. : IP-CALC-09-00265 I REVISION NO. 0 I
ATTACHMENT 9.2 ENGINEERING CALCULAT10N COVER PAGE Sheet 1 of 1 o ANO-l OANO-2 OGGNS
- IP-2
- IP-3 OPLP OJAF OPNPS ORBS OVY o W3 o NP-GGNS-3 o NP-RBS-3 CALCULATION (1) EC # 18781 (2)Page 1 of 17 COVER PAGE (a total of 258 pages incl. attachment)
(3) Design Basis CalcO YES (5) Calculation No: IP-CALC-09-00265
.NO (4)
- CALCULATION o EC Markup (6) Revision: 0 (II)
(7)
Title:
- Re-analysis of MACCS2 Models for IPEC Editorial:
0 YES .NO (9) System(s): NA (IU) Review Org (Department): PSA (11) Safety Class: (12) ComponentiEquipmentlStructure Type/Number:
o Safety! Quality Related o Augmented Quality Program
- Non-Safety Related (13) Document Type: Calculation (14)
Keywords (Description/Topical Codes): MACCS2 REVIEWS (15) NamelSignaturelD~ (16) NamelSign~te (17) NamelSignaturelDate K. Hong .~ 7...£. ~ /- 0/61 M. Golshani
~
-~
- Jc;y I
- c. Yeh ~ 1:fv/1 Responsible Engineer 0 Design Verifier Supervisor!Approval
- Reviewer o Comments Attached o Comments Attached
CALCULATION CONTINUATION SHEET SHEET No. 2 of 17 CALC. TITLE: Re-analysis of MACCS2 Models for IPEC CALC. NO.: IP-CALC-09-00265 REVISION NO. 0 I. EC Markups Incorporated - none II. Relationships: Sec. Rev Input Output Impact Tracking No.
Doc Doc Y/N ENERCON Report - 1 N N/A REA-03-04 - 0 N N/A REA-03-40 - 0 N N/A III. CROSS
REFERENCES:
NUREG/CR-4551, Vol. 2, Rev. 1 IV. SOFTWARE USED:
Title:
MACCS2 Version/Release: 1.13.1 Disk/CD No.
V. DISK/CDS INCLUDED: No, See Attachment
Title:
Version/Release Disk/CD No.
VI. OTHER CHANGES:
CALCULATION CONTINUATION SHEET SHEET No. 3 of 17 CALC. TITLE: Re-analysis of MACCS2 Models for IPEC CALC. NO.: IP-CALC-09-00265 REVISION NO. 0 ATTACHMENT 9.4 RECORD OF REVISION Sheet 1 of 1 Revision Record of Revision 0 Initial issue.
CALCULATION CONTINUATION SHEET SHEET No. 4 of 17 CALC. TITLE: Re-analysis of MACCS2 Models for IPEC CALC. NO.: IP-CALC-09-00265 REVISION NO. 0 TABLE OF CONTENTS Section Sheet No.
Calculation Cover Page ............................. 1 Calculation Reference Sheet.......................... 2 Record of Revision ................................. 3 Table of Contents ................................. 4 List of Effective pages ............................ 5 1.0 PURPOSE ...................................... 6 2.0 Summary of Results ............................ 7 3.0 Input Data ..................................... 8 4.0 Methodology .................................. 11 5.0 Analysis & Results ............................ 12 5.1 Assumptions ........................ 12 5.2 Results ............................... 16 6.0 References .................................. 17 Attachment A MACCS2 Input and Output File 241 pages Attachment A.1 IP2 MACCS2 Input and Output File Attachment A.2 IP3 MACCS2 Input and Output File
CALCULATION CONTINUATION SHEET SHEET No. 5 of 17 CALC.TITLE: Re-analysis of MACCS2 Models for IPEC CALC. NO.: IP-CALC-09-00265 REVISION NO. 0 List of Effective Pages Page No. Revision Page No. Revision 1 - 17 0
CALCULATION CONTINUATION SHEET SHEET No. 6 of 17 CALC.TITLE: Re-analysis of MACCS2 Models for IPEC CALC. NO.: IP-CALC-09-00265 REVISION NO. 0 1.0 Purpose The purpose of this calculation is to re-analyze the baseline population dose risk (PDR) and offsite economic cost risk (OECR) to support the severe accident mitigation alternative (SAMA) evaluations required for IPEC license renewal application using Year 2000 meteorological data. The baseline case includes economic losses due to tourism and business. The re-analysis is required to address an error found in methodology used to derive five year average wind direction input into the computer code, MACCS2, used for the SAMA evaluations. In the re-analysis, a single year (i.e. Year 2000) rather than the five year average is used. The previous IP2 and IP3 analyses are documented in calculations IP-CALC-07-00016 [Ref. 1] and IP-CALC-07-00019 [Ref. 2], respectively.
CALCULATION CONTINUATION SHEET SHEET No. 7 of 17 CALC.TITLE: Re-analysis of MACCS2 Models for IPEC CALC. NO.: IP-CALC-09-00265 REVISION NO. 0 2.0 Summary of Results The baseline case was evaluated using MACCS2 with site specific source term information, no evacuation scenario, and inclusion of economic losses due to tourism and business.
For IP2, the estimated mean values of PDR and OECR from postulated internal events are 87.4 person-rem/yr and $212,000/yr, respectively.
For IP3, the estimated mean values of PDR and OECR from postulated internal events are 94.8 person-rem/yr and $261,000/yr, respectively.
CALCULATION CONTINUATION SHEET SHEET No. 8 of 17 CALC.TITLE: Re-analysis of MACCS2 Models for IPEC CALC. NO.: IP-CALC-09-00265 REVISION NO. 0 3..0 Input Data Key input data common to IP2 and IP3 are listed for the following modules:
ATMOS
- 1. Containment dimensions: (Refs. 3, 4)
Width (W) = 42.5m Height (H) = 66.8m
- 2. Initial value of dispersion parameters: (Ref. 5)
Sigma-y = W/4.3 = 42.5/4.3 = 9.9 m Sigma-z = H/2.15 = 66.8/2.15 = 31.1 m CHRONC (Ref. 6)
- 1. Value of farm wealth in the region = $50,071/hectare
- 2. Fraction of farm wealth in the region due to improvements = 0.25
- 3. Value of non-farm wealth in the region = $208,838/person
- 4. Fraction of non-farm wealth in the region due to improvements = 0.8 METEOROLOGICAL DATA (Ref. 6)
The meteorological data are hourly measured data of Year 2000.
SITE DATA (Ref. 6)
The site data include population distribution, land fractions, watershed index, crop season and share, watershed definition, and regional economic data. The data were derived in Ref. 6 and included in the MACCS2 files of Attachment A.
Source term information tables are site specific. The source terms are given in Table 1 and Table 2 for IP2, and IP3, respectively.
Other input data were obatained from Ref. 5 and Ref. 7 and included in Attachment A.
CALCULATION CONTINUATION SHEET SHEET No. 9 of 17 CALC.TITLE: Re-analysis of MACCS2 Models for IPEC CALC. NO.: IP-CALC-09-00265 REVISION NO. 0 Table 1 Source Terms for Postulated Internal Events at IP2 Warning Release Release Release Release Fractions Release Frequency Time Elevation Start Duration Energy Mode (/year) (sec) (m) (sec) (sec) (W) NG I Cs Te Sr Ru La Ce Ba 1 NCF 1.19E-05 1.66E+04 3.00E+01 0.00E+00 1.28E+05 9.20E+05 9.27E-05 3.94E-06 1.61E-06 1.21E-06 3.74E-08 2.37E-07 2.11E-09 1.77E-08 1.05E-07 EARLY 2 6.50E-07 1.36E+04 3.00E+01 1.32E+04 8.24E+04 1.08E+06 7.01E-01 2.43E-01 2.29E-01 2.26E-01 2.47E-02 9.13E-02 7.95E-04 4.84E-03 4.56E-02 HIGH EARLY 3 4.23E-07 1.00E+04 3.00E+01 1.25E+04 9.72E+04 1.33E+06 9.87E-01 2.02E-02 1.75E-02 2.66E-02 8.33E-04 2.03E-02 4.92E-05 3.28E-04 1.33E-02 MEDIUM EARLY 4 1.11E-07 1.09E+04 3.00E+01 1.73E+04 1.16E+05 1.60E+06 7.55E-01 5.93E-03 4.06E-03 3.89E-03 1.04E-04 1.97E-03 4.58E-06 3.31E-05 7.75E-04 LOW 5 LATE HIGH 6.88E-07 5.58E+03 3.00E+01 7.38E+04 1.30E+05 9.20E+05 9.89E-01 1.17E-01 2.26E-02 4.81E-03 2.08E-04 3.74E-03 1.32E-05 1.22E-04 9.06E-04 LATE 6 3.43E-06 8.94E+03 3.00E+01 8.04E+04 1.30E+05 9.20E+05 8.23E-01 1.53E-02 4.30E-03 1.49E-03 8.01E-05 1.44E-03 5.11E-06 4.72E-05 3.50E-04 MEDIUM 7 LATE LOW 6.43E-07 2.19E+04 3.00E+01 9.90E+04 1.30E+05 9.20E+05 6.98E-01 1.06E-03 7.91E-04 1.23E-03 8.69E-05 3.47E-06 2.59E-06 2.38E-05 7.42E-05 LATE 8 5.82E-08 2.56E+04 3.00E+01 1.13E+05 1.30E+05 9.20E+05 9.09E-01 8.14E-04 6.96E-04 7.55E-04 3.63E-05 2.08E-06 1.14E-06 1.20E-05 3.33E-05 LOWLOW
CALCULATION CONTINUATION SHEET SHEET No. 10 of 17 CALC.TITLE: Re-analysis of MACCS2 Models for IPEC CALC. NO.: IP-CALC-09-00265 REVISION NO. 0 Table 2 Source Terms for Postulated Internal Events at IP3 Warning Release Release Release Release Fractions Release Frequency Time Elevation Start Duration Energy Mode (/year) (sec) (m) (sec) (sec) (W) NG I Cs Te Sr Ru La Ce Ba 1 NCF 6.30E-06 1.26E+04 3.00E+01 0.00E+00 1.27E+05 9.20E+05 9.62E-05 6.51E-06 2.65E-06 2.08E-06 6.09E-08 5.20E-07 3.26E-09 2.72E-08 1.79E-07 EARLY 2 9.43E-07 1.27E+04 3.00E+01 1.20E+04 7.92E+04 1.03E+06 6.35E-01 1.63E-01 1.48E-01 1.47E-01 1.57E-02 6.48E-02 5.55E-04 3.03E-03 3.07E-02 HIGH EARLY 3 1.24E-06 9.18E+03 3.00E+01 9.22E+03 8.21E+04 1.07E+06 9.87E-01 1.31E-02 1.18E-02 2.65E-02 8.51E-04 2.95E-02 5.17E-05 3.07E-04 1.95E-02 MEDIUM EARLY 4 1.46E-07 9.31E+03 3.00E+01 9.90E+03 8.49E+04 1.11E+06 2.43E-01 2.03E-03 1.62E-03 2.90E-03 8.98E-05 2.97E-03 5.17E-06 3.11E-05 1.87E-03 LOW 5 LATE HIGH 4.23E-07 5.58E+03 3.00E+01 7.38E+04 1.30E+05 9.20E+05 9.89E-01 1.17E-01 2.26E-02 4.81E-03 2.08E-04 3.74E-03 1.32E-05 1.22E-04 9.06E-04 LATE 6 2.01E-06 7.17E+03 3.00E+01 7.70E+04 1.30E+05 9.20E+05 8.23E-01 1.53E-02 4.30E-03 1.49E-03 8.01E-05 1.44E-03 5.11E-06 4.72E-05 3.50E-04 MEDIUM 7 LATE LOW 3.75E-07 2.19E+04 3.00E+01 9.13E+04 1.30E+05 9.20E+05 6.98E-01 1.06E-03 7.91E-04 1.23E-03 8.69E-05 3.47E-06 2.59E-06 2.38E-05 7.41E-05 LATE 8 5.66E-08 2.56E+04 3.00E+01 1.13E+05 1.30E+05 9.20E+05 9.09E-01 8.14E-04 6.96E-04 7.55E-04 3.63E-05 2.08E-06 1.14E-06 1.20E-05 3.33E-05 LOWLOW
CALCULATION CONTINUATION SHEET SHEET No. 11 of 17 CALC.TITLE: Re-analysis of MACCS2 Models for IPEC CALC. NO.: IP-CALC-09-00265 REVISION NO. 0 4.0 Methodology MACCS2 was used to calculate the consequences of atmospheric releases of radiological materials from postulated severe accidents. The principal consequences considered in this calculation are population dose and offsite economic cost resulting from the releases.
A MACCS2 calculation consists of three phases: input processing and validation, phenomenological modeling and output processing. The phenomenological models are based mostly on empirical data. The modeling software is subdivided into three modules:
x ATMOS treats atmospheric transport and dispersion of material and its deposition from the air utilizing a Gaussian plume model with Pasquill-Gifford dispersion parameters.
x EARLY models consequences of the accident to the surrounding area during an emergency action period.
x CHRONC considers the long-term impact in the period subsequent to the emergency action period.
Detailed site-specific meteorological, population and economic data are required. Model parameters can be varied by the user via input files, thus facilitating the analysis of consequence sensitivities due to uncertainties in specific model parameters.
This calculation evaluates a baseline case to provide best-estimated consequences for postulated internal events. Instead of considering various emergency planning scenarios, the baseline case uses a conservative assumption of no evacuation.
The population dose risk (PDR) was estimated by summing the product of population dose, obtained from the MACCS2 calculation, and frequency for each accidental release over all releases. The same process was used to estimate offsite economic cost risk (OECR). The offsite economic cost includes the cost that could incur during emergency response phase and long-term protective actions.
CALCULATION CONTINUATION SHEET SHEET No. 12 of 17 CALC. TITLE: Re-analysis of MACCS2 Models for IPEC CALC. NO.: IP-CALC-09-00265 REVISION NO. 0 5.0 Analysis and Results 5.1 Assumptions 5.1.1 Assumptions common to IP2 and IP3 Major assumptions included in this calculation are as follows:
- 1. The base case assumes a conservative no evacuation scenario.
- 2. The Consumer Price Index (CPI) is assumed to be 195.3, which is the average value for Year 2005.
- 3. Population distributions are projected for Year 2035. County level permanent population projections were obtained from the New York Statistical Information System from 2000 to 2030, the New Jersey Department of Labor and Workforce Development from 2000 to 2025, the Connecticut State Data Center from 2000 to 2020, and the Pennsylvania State Data Center from 2000 to 2020. Population estimates for Connecticut were provided by municipalities and converted to county to maintain consistency.
5.1.2 Assumptions specific to IP2 Core inventory (Table 3) is based on a power level of 3216 MWth. The values are derived from ORIGEN2 results based on the fuel management data for the proposed fuel management designs for Cycles 16, 17, 18, and 19 (Ref. 8).
CALCULATION CONTINUATION SHEET SHEET No. 13 of 17 CALC. TITLE: Re-analysis of MACCS2 Models for IPEC CALC. NO.: IP-CALC-09-00265 REVISION NO. 0 Table 3 Estimated IP2 Core Inventory (Becquerels)*
Nuclide Inventory Nuclide Inventory Co-58 3.04E+16 Te-131m 4.64E+17 Co-60 2.32E+16 Te-132 4.57E+18 Kr-85 3.84E+16 I-131 3.20E+18 Kr-85m 8.48E+17 I-132 4.64E+18 Kr-87 1.63E+18 I-133 6.56E+18 Kr-88 2.29E+18 I-134 7.19E+18 Rb-86 8.31E+15 I-135 6.11E+18 Sr-89 3.08E+18 Xe-133 6.28E+18 Sr-90 3.05E+17 Xe-135 1.67E+18 Sr-91 3.87E+18 Cs-134 7.19E+17 Sr-92 4.19E+18 Cs-136 2.10E+17 Y-90 3.18E+17 Cs-137 4.15E+17 Y-91 3.98E+18 Ba-139 5.83E+18 Y-92 4.19E+18 Ba-140 5.62E+18 Y-93 4.85E+18 La-140 6.04E+18 Zr-95 5.38E+18 La-141 5.34E+18 Zr-97 5.41E+18 La-142 5.17E+18 Nb-95 5.45E+18 Ce-141 5.31E+18 Mo-99 6.11E+18 Ce-143 4.96E+18 Tc-99m 5.34E+18 Ce-144 4.19E+18 Ru-103 4.89E+18 Pr-143 4.78E+18 Ru-105 3.36E+18 Nd-147 2.13E+18 Ru-106 1.71E+18 Np-239 6.56E+19 Rh-105 3.09E+18 Pu-238 1.44E+16 Sb-127 3.47E+17 Pu-239 1.22E+15 Sb-129 1.04E+18 Pu-240 1.83E+15 Te-127 3.43E+17 Pu-241 4.12E+17 Te-127m 4.50E+16 Am-241 4.92E+14 Te-129 1.02E+18 Cm-242 1.23E+17 Te-129m 1.50E+17 Cm-244 1.33E+16
- Derived from Ref. 8 for a power level of 3216 MWth except Co-58 and Co-60, which were power scaled from the reference inventory given in Ref. 5.
CALCULATION CONTINUATION SHEET SHEET No. 14 of 17 CALC. TITLE: Re-analysis of MACCS2 Models for IPEC CALC. NO.: IP-CALC-09-00265 REVISION NO. 0 5.1.3 Assumptions specific to IP3 Core inventory (Table 4) is based on a power level of 3216 MWth. The values are derived from ORIGEN2 results based on the fuel management data for the proposed fuel management designs for Cycles 14, 15 and 16 (Ref. 9).
CALCULATION CONTINUATION SHEET SHEET No. 15 of 17 CALC. TITLE: Re-analysis of MACCS2 Models for IPEC CALC. NO.: IP-CALC-09-00265 REVISION NO. 0 Table 4 Estimated IP3 Core Inventory (Becquerels)*
Nuclide Inventory Nuclide Inventory Co-58 3.04E+16 Te-131m 4.64E+17 Co-60 2.32E+16 Te-132 4.54E+18 Kr-85 3.87E+16 I-131 3.18E+18 Kr-85m 8.52E+17 I-132 4.64E+18 Kr-87 1.64E+18 I-133 6.56E+18 Kr-88 2.30E+18 I-134 7.19E+18 Rb-86 8.24E+15 I-135 6.14E+18 Sr-89 3.09E+18 Xe-133 6.25E+18 Sr-90 3.07E+17 Xe-135 1.67E+18 Sr-91 3.87E+18 Cs-134 7.16E+17 Sr-92 4.19E+18 Cs-136 2.08E+17 Y-90 3.20E+17 Cs-137 4.15E+17 Y-91 3.98E+18 Ba-139 5.86E+18 Y-92 4.22E+18 Ba-140 5.58E+18 Y-93 4.85E+18 La-140 5.76E+18 Zr-95 5.38E+18 La-141 5.34E+18 Zr-97 5.41E+18 La-142 5.17E+18 Nb-95 5.45E+18 Ce-141 5.31E+18 Mo-99 6.11E+18 Ce-143 4.99E+18 Tc-99m 5.34E+18 Ce-144 4.19E+18 Ru-103 4.85E+18 Pr-143 4.78E+18 Ru-105 3.34E+18 Nd-147 2.12E+18 Ru-106 1.69E+18 Np-239 6.53E+19 Rh-105 3.08E+18 Pu-238 1.43E+16 Sb-127 3.45E+17 Pu-239 1.22E+15 Sb-129 1.04E+18 Pu-240 1.82E+15 Te-127 3.43E+17 Pu-241 4.08E+17 Te-127m 4.47E+16 Am-241 5.03E+14 Te-129 1.02E+18 Cm-242 1.21E+17 Te-129m 1.49E+17 Cm-244 1.29E+16
- Derived from Ref. 9 for a power level of 3216 MWth except Co-58 and Co-60, which were power scaled from the reference inventory given in Ref. 5.
CALCULATION CONTINUATION SHEET SHEET No. 16 of 17 CALC. TITLE: Re-analysis of MACCS2 Models for IPEC CALC. NO.: IP-CALC-09-00265 REVISION NO. 0 5.2 Results Risk estimates for baseline case were analyzed with MACCS2. The baseline mean risk values for postulated internal events are given in Table 5 and Table 6 for IP2 and IP3, respectively.
Table 5 IP2 Mean PDR and OECR Using Year 2000 Meteorological Data Offsite Population Offsite Population Economic Dose Risk Economic Cost Release Frequency Dose Cost (PDR) Risk (OECR)
Mode (/yr) (person-sv)* ($) (person-rem/yr) ($/yr)
NCF 1.19E-05 4.75E+01 9.98E+04 5.64E-02** 1.18E+00 EARLY HIGH 6.50E-07 6.51E+05 2.05E+11 4.23E+01 1.33E+05 EARLY MEDIUM 4.23E-07 1.94E+05 5.87E+10 8.21E+00 2.48E+04 EARLY LOW 1.11E-07 7.93E+04 6.39E+09 8.81E-01 7.10E+02 LATE HIGH 6.88E-07 1.63E+05 4.64E+10 1.12E+01 3.19E+04 LATE MEDIUM 3.43E-06 6.87E+04 6.06E+09 2.36E+01 2.08E+04 LATE LOW 6.43E-07 1.61E+04 6.59E+08 1.04E+00 4.24E+02 LATE LOWLOW 5.82E-08 1.38E+04 5.62E+08 8.04E-02 3.27E+01 Totals 8.74E+01 2.12E+05
- 1 sv = 100 rem
- 5.64E-02 (person-rem/yr) = 1.19E-05 (/yr) x 4.75E+01 (person-sv) x 100 (rem/sv)
Table 6 IP3 Mean PDR and OECR Using Year 2000 Meteorological Data Offsite Population Offsite Population Economic Dose Risk Economic Cost Release Frequency Dose Cost (PDR) Risk (OECR)
Mode (/yr) (person-sv)* ($) (person-rem/yr) ($/yr)
NCF 6.30E-06 8.04E+01 2.95E+05 5.06E-02** 1.86E+00 EARLY HIGH 9.43E-07 5.08E+05 1.70E+11 4.79E+01 1.60E+05 EARLY MEDIUM 1.24E-06 2.00E+05 5.55E+10 2.47E+01 6.87E+04 EARLY LOW 1.46E-07 5.21E+04 3.58E+09 7.59E-01 5.21E+02 LATE HIGH 4.23E-07 1.63E+05 4.61E+10 6.89E+00 1.95E+04 LATE MEDIUM 2.01E-06 6.85E+04 6.06E+09 1.37E+01 1.22E+04 LATE LOW 3.75E-07 1.61E+04 6.58E+08 6.03E-01 2.47E+02 LATE LOWLOW 5.66E-08 1.38E+04 5.62E+08 7.81E-02 3.18E+01 Totals 9.48E+01 2.61E+05
- 1 sv = 100 rem
- 5.06E-02 (person-rem/yr) = 6.30E-06 (/yr) x 8.04E+01 (person-sv) x 100 (rem/sv)
CALCULATION CONTINUATION SHEET SHEET No. 17 of 17 CALC. TITLE: Re-analysis of MACCS2 Models for IPEC CALC. NO.: IP-CALC-09-00265 REVISION NO. 0
6.0 REFERENCES
- 1. IP2 Calculation IP-CALC-07-00016, MACCS2 Model for IP2
- 2. IP3 Calculation IP-CALC-07-00019, MACCS2 Model for IP3
- 3. IP2 Final Safety Analysis Report, Figure 5.1-5
- 4. IP3 Final Safety Analysis Report, Figure 5.1-5
- 5. SAND97-0594, Code Manual for MACCS2: Volume 1, Users Guide, Sandia National Laboratories, March 1997
- 6. ENERCON Services: Site Specific MACCS2 Input Data for Indian Point Energy Center, Rev. 1
- 7. NUREG/CR-4551, Vol. 2, Rev. 1, Part 7, Evaluation of Severe Accident Risks:
Quantification of Major Input Parameters, MACCS Input, December 1990
- 8. IP2 Calculation REA-03-4: Core Radiation Sources to Support Indian Point 2 Power Uprate Project, Westinghouse Electric Company, CN-REA-03-4
- 9. IP3 Calculation REA-03-40: Core Radiation Sources to Support Indian Point 3 SPU Project, Westinghouse Electric Company, CN-REA-03-40
ENTERGY - Calculation No. IP-CALC-09-00265, Rev. 0 MACCS2 Models for IPEC Attachment A MACCS2 Input and Output File Attachment A lists all MACCS2 files generated for this calculation. Each MACCS2 file includes input data and results output. The files appear in the following order:
A.1 IP2 MACCS2 Input and Output File A.2 IP2 MACCS2 Input and Output File
ENTERGY - Calculation No. IP-CALC-09-00265, Rev. 0 MACCS2 Models for IPEC Attachment A.1 IP2 MACCS2 Input and Output File
Calculation IP-CALC-09-00265, Rev. 0, Att. A.1, Page 1 MACCS2 11-NOV-09 19:34:05 VERSION 1.13.1: last revised 1/8/04, K. McFadden P1: ATMOS USER INPUT (UNIT 24) = atmbi2NS.INP P2: EARLY USER INPUT (UNIT 25) = earbi-noE.INP P3: CHRONC USER INPUT (UNIT 26) = chrbiEC.INP P4: METEOROLOGY DATA (UNIT 28) = meti00.INP P5: SITE DATA INPUT (UNIT 29) = siteiEC.INP P6: LIST OUTPUT (UNIT 06) = conbi2NS-noE-NmetEC.OUT USER INPUT IS READ FROM UNIT 24 RECORD IDENTIFIER FIELDS 11 CHARACTERS LONG ARE EXPECTED.
THE FIRST 100 COLUMNS OF EACH INPUT RECORD ARE PROCESSED.
THE MAXIMUM NUMBER OF IDENTIFIER RECORDS THAT MAY BE SAVED AS THE BASE CASE IS 1000.
RECORD NUMBER RECORD
- GENERAL DESCRIPTIVE TITLE DESCRIBING THIS "ATMOS" INPUT 1 RIATNAM1001 'ATMOS INPUT FOR IPEC CALCULATIONS'
- GEOMETRY DATA BLOCK, LOADED BY INPGEO, STORED IN /GEOM/
- NUMBER OF RADIAL SPATIAL ELEMENTS 2 GENUMRAD001 15 3 GESPAEND001 0.32 1.61 3.22 4.83 6.44 4 GESPAEND002 8.05 9.66 11.27 12.87 14.48 5 GESPAEND003 16.09 32.19 48.28 64.37 80.47
- NUCLIDE DATA BLOCK, LOADED BY INPISO, STORED IN /ISOGRP/, /ISONAM/
- Number of pseudo-stable nuclides (used to truncate the decay chains) 6 ISNUMSTB001 27
- List of pseudo-stable nuclides 7 ISNAMSTB001 I-129 (daughter of Te-129 and Te-129m) 8 ISNAMSTB002 Xe-131m (daughter of I-131) 9 ISNAMSTB003 Xe-133m (daughter of I-133) 10 ISNAMSTB004 Xe-135m (daughter of I-135) 11 ISNAMSTB005 Cs-135 (daughter of Xe-135 and Xe-135m) 12 ISNAMSTB006 Sm-147 (daughter of Pm-147) 13 ISNAMSTB007 U-234 (daughter of Pu-238) 14 ISNAMSTB008 U-235 (daughter of Pu-239) 15 ISNAMSTB009 U-236 (daughter of Pu-240) 16 ISNAMSTB010 U-237 (daughter of Pu-241) 17 ISNAMSTB011 Np-237 (daughter of Am-241) 18 ISNAMSTB012 Rb-87 (daughter of Kr-87) 19 ISNAMSTB013 Ba-137m (daughter of Cs-137) 20 ISNAMSTB014 Rb-88 (daughter of Kr-88) 21 ISNAMSTB015 Y-91m (daughter of Sr-91) 22 ISNAMSTB016 Zr-93 (daughter of Y-93) 23 ISNAMSTB017 Nb-93m (daughter of Zr-93)
Calculation IP-CALC-09-00265, Rev. 0, Att. A.1, Page 2 24 ISNAMSTB018 Nb-95m (daughter of Zr-95) 25 ISNAMSTB019 Nb-97 (daughter of Zr-97 and Nb-97m) 26 ISNAMSTB020 Nb-97m (daughter of Zr-97) 27 ISNAMSTB021 Tc-99 (daughter of Mo-99) 28 ISNAMSTB022 Rh-103m (daughter of Ru-103) 29 ISNAMSTB023 Rh-106 (daughter of Ru-106) 30 ISNAMSTB024 Te-131 (daughter of Te-131m) 31 ISNAMSTB025 Pr-144 (daughter of Ce-144 and Pr-144m) 32 ISNAMSTB026 Pr-144m (daughter of Ce-144) 33 ISNAMSTB027 Pm-147 (daughter of Nd-147)
- Number of radioactive nuclides to be considered 34 ISNUMISO001 60
- NUMBER OF NUCLIDE GROUPS 35 ISMAXGRP001 9
- WET AND DRY DEPOSITION FLAGS FOR EACH NUCLIDE GROUP
- WETDEP DRYDEP 36 ISDEPFLA001 .FALSE. .FALSE.
37 ISDEPFLA002 .TRUE. .TRUE.
38 ISDEPFLA003 .TRUE. .TRUE.
39 ISDEPFLA004 .TRUE. .TRUE.
40 ISDEPFLA005 .TRUE. .TRUE.
41 ISDEPFLA006 .TRUE. .TRUE.
42 ISDEPFLA007 .TRUE. .TRUE.
43 ISDEPFLA008 .TRUE. .TRUE.
44 ISDEPFLA009 .TRUE. .TRUE.
- NUCLIDE GROUP DATA FOR 9 NUCLIDE GROUPS
- NUCNAM IGROUP 45 ISOTPGRP001 Co-58 6 46 ISOTPGRP002 Co-60 6 47 ISOTPGRP003 Kr-85 1 48 ISOTPGRP004 Kr-85m 1 49 ISOTPGRP005 Kr-87 1 50 ISOTPGRP006 Kr-88 1 51 ISOTPGRP007 Rb-86 3 52 ISOTPGRP008 Sr-89 5 53 ISOTPGRP009 Sr-90 5 54 ISOTPGRP010 Sr-91 5 55 ISOTPGRP011 Sr-92 5 56 ISOTPGRP012 Y-90 7 57 ISOTPGRP013 Y-91 7 58 ISOTPGRP014 Y-92 7 59 ISOTPGRP015 Y-93 7 60 ISOTPGRP016 Zr-95 7 61 ISOTPGRP017 Zr-97 7 62 ISOTPGRP018 Nb-95 7 63 ISOTPGRP019 Mo-99 6 64 ISOTPGRP020 Tc-99m 6 65 ISOTPGRP021 Ru-103 6 66 ISOTPGRP022 Ru-105 6
Calculation IP-CALC-09-00265, Rev. 0, Att. A.1, Page 3 67 ISOTPGRP023 Ru-106 6 68 ISOTPGRP024 Rh-105 6 69 ISOTPGRP025 Sb-127 4 70 ISOTPGRP026 Sb-129 4 71 ISOTPGRP027 Te-127 4 72 ISOTPGRP028 Te-127m 4 73 ISOTPGRP029 Te-129 4 74 ISOTPGRP030 Te-129m 4 75 ISOTPGRP031 Te-131m 4 76 ISOTPGRP032 Te-132 4 77 ISOTPGRP033 I-131 2 78 ISOTPGRP034 I-132 2 79 ISOTPGRP035 I-133 2 80 ISOTPGRP036 I-134 2 81 ISOTPGRP037 I-135 2 82 ISOTPGRP038 Xe-133 1 83 ISOTPGRP039 Xe-135 1 84 ISOTPGRP040 Cs-134 3 85 ISOTPGRP041 Cs-136 3 86 ISOTPGRP042 Cs-137 3 87 ISOTPGRP043 Ba-139 9 88 ISOTPGRP044 Ba-140 9 89 ISOTPGRP045 La-140 7 90 ISOTPGRP046 La-141 7 91 ISOTPGRP047 La-142 7 92 ISOTPGRP048 Ce-141 8 93 ISOTPGRP049 Ce-143 8 94 ISOTPGRP050 Ce-144 8 95 ISOTPGRP051 Pr-143 7 96 ISOTPGRP052 Nd-147 7 97 ISOTPGRP053 Np-239 8 98 ISOTPGRP054 Pu-238 8 99 ISOTPGRP055 Pu-239 8 100 ISOTPGRP056 Pu-240 8 101 ISOTPGRP057 Pu-241 8 102 ISOTPGRP058 Am-241 7 103 ISOTPGRP059 Cm-242 7 104 ISOTPGRP060 Cm-244 7
- WET DEPOSITION DATA BLOCK, LOADED BY INPWET, STORED IN /WETCON/
- WASHOUT COEFFICIENT NUMBER ONE, LINEAR FACTOR 105 WDCWASH1001 9.5E-5 (JON HELTON AFTER JONES, 1986)
- WASHOUT COEFFICIENT NUMBER TWO, EXPONENTIAL FACTOR 106 WDCWASH2001 0.8 (JON HELTON AFTER JONES, 1986)
- DRY DEPOSITION DATA BLOCK, LOADED BY INPDRY, STORED IN /DRYCON/
- NUMBER OF PARTICLE SIZE GROUPS 107 DDNPSGRP001 1
- DEPOSITION VELOCITY OF EACH PARTICLE SIZE GROUP (M/S) 108 DDVDEPOS001 0.01 (VALUE SELECTED BY S. ACHARYA, NRC)
Calculation IP-CALC-09-00265, Rev. 0, Att. A.1, Page 4
- DISPERSION PARAMETER DATA BLOCK, LOADED BY INPDIS, STORED IN /DISPY/, /DISPZ/
- # of distances in plume-size tables--which can be used as an alternative to the power-law model:
- (to utilize the power-law model, set NUM_DIST to zero or delete the following data card) 109 NUM_DIST001 0
- SIGMA = A
- X ** B
- Tadmor and Gur Parameterization for Distance Range 0.5 to 5.0 km
- as taken from Atmospheric Motion and Air Pollution (Dobbins 1979).
- P-G CLASS: A B C D E F 110 DPCYSIGA001 0.3658 0.2751 0.2089 0.1474 0.1046 0.0722 111 DPCYSIGB001 0.9031 0.9031 0.9031 0.9031 0.9031 0.9031 112 DPCZSIGA001 2.5E-4 1.9E-3 0.2 0.3 0.4 0.2 113 DPCZSIGB001 2.125 1.6021 0.8543 0.6532 0.6021 0.6020
- LINEAR SCALING FACTOR FOR SIGMA-Y FUNCTION, NORMALLY 1 114 DPYSCALE001 1.
- LINEAR SCALING FACTOR FOR SIGMA-Z FUNCTION,
- NORMALLY USED FOR SURFACE ROUGHNESS LENGTH CORRECTION.
- EXPANSION FACTOR DATA BLOCK, LOADED BY INPEXP, STORED IN /EXPAND/
- TIME BASE FOR EXPANSION FACTOR (SECONDS) 116 PMTIMBAS001 600. (10 MINUTES)
- BREAK POINT FOR FORMULA CHANGE (SECONDS) 117 PMBRKPNT001 3600. (1 HOUR)
- EXPONENTIAL EXPANSION FACTOR NUMBER 1 118 PMXPFAC1001 0.2
- EXPONENTIAL EXPANSION FACTOR NUMBER 2 119 PMXPFAC2001 0.25
- PLUME RISE DATA BLOCK, LOADED BY INPLRS, STORED IN /PLUMRS/
- SCALING FACTOR FOR THE CRITICAL WIND SPEED FOR ENTRAINMENT OF A BOUYANT PLUME
- (USED BY FUNCTION CAUGHT) 120 PRSCLCRW001 1.
- SCALING FACTOR FOR THE A-D STABILITY PLUME RISE FORMULA
- (USED BY FUNCTION PLMRIS) 121 PRSCLADP001 1.
- SCALING FACTOR FOR THE E-F STABILITY PLUME RISE FORMULA
- (USED BY FUNCTION PLMRIS)
Calculation IP-CALC-09-00265, Rev. 0, Att. A.1, Page 5 122 PRSCLEFP001 1.
- RELEASE DATA BLOCK, LOADED BY INPREL, STORED IN /ATNAM2/, /MULREL/
- RELEASE DATA BLOCK ************
- SOURCE TERM NUMBER 1 OF 8 123 RDATNAM2001 'NCF'
- TIME AFTER ACCIDENT INITIATION WHEN THE ACCIDENT REACHES GENERAL EMERGENCY
- CONDITIONS (AS DEFINED IN NUREG-0654), OR WHEN PLANT PERSONNEL CAN RELIABLY
- PREDICT THAT GENERAL EMERGENCY CONDITIONS WILL BE ATTAINED 124 RDOALARM001 1.66E+04
- NUMBER OF PLUME SEGMENTS THAT ARE RELEASED 125 RDNUMREL001 1
- SELECTION OF RISK DOMINANT PLUME 126 RDMAXRIS001 1
- REFERENCE TIME FOR DISPERSION AND RADIOACTIVE DECAY 127 RDREFTIM001 0.5
- HEAT CONTENT OF THE RELEASE SEGMENTS (W)
- A VALUE SPECIFIED FOR EACH OF THE RELEASE SEGMENTS 128 RDPLHEAT001 9.20E+05
- HEIGHT OF THE PLUME SEGMENTS AT RELEASE (M)
- A VALUE SPECIFIED FOR EACH OF THE RELEASE SEGMENTS 129 RDPLHITE001 30.
- DURATION OF THE PLUME SEGMENTS (S)
- A VALUE SPECIFIED FOR EACH OF THE RELEASE SEGMENTS 130 RDPLUDUR001 8.64E+04
- TIME OF RELEASE FOR EACH PLUME (S AFTER SCRAM)
- A VALUE SPECIFIED FOR EACH OF THE RELEASE SEGMENTS 131 RDPDELAY001 0.00E+00
- Initial value of sigma-y for each plume--Note: values required for each plume 132 SIGYINIT001 9.9 (initial sigma-y = W/4.3 = 42.5/4.3)
- Initial value of sigma-z for each plume--Note: values required for each plume 133 SIGZINIT001 31.1 (initial sigma-z = H/2.15 = 66.8/2.15)
- Building height (meters)--Note: values required for each plume 134 WEBUILDH001 66.8
- PARTICLE SIZE DISTRIBUTION OF EACH NUCLIDE GROUP
Calculation IP-CALC-09-00265, Rev. 0, Att. A.1, Page 6
- YOU MUST SPECIFY A COLUMN OF DATA FOR EACH OF THE PARTICLE SIZE GROUPS 135 RDPSDIST001 1.
136 RDPSDIST002 1.
137 RDPSDIST003 1.
138 RDPSDIST004 1.
139 RDPSDIST005 1.
140 RDPSDIST006 1.
141 RDPSDIST007 1.
142 RDPSDIST008 1.
143 RDPSDIST009 1.
- NUCNAM CORINV (Bq) 144 RDCORINV001 Co-58 3.04E+16 145 RDCORINV002 Co-60 2.32E+16 146 RDCORINV003 Kr-85 3.84E+16 147 RDCORINV004 Kr-85m 8.48E+17 148 RDCORINV005 Kr-87 1.63E+18 149 RDCORINV006 Kr-88 2.29E+18 150 RDCORINV007 Rb-86 8.31E+15 151 RDCORINV008 Sr-89 3.08E+18 152 RDCORINV009 Sr-90 3.05E+17 153 RDCORINV010 Sr-91 3.87E+18 154 RDCORINV011 Sr-92 4.19E+18 155 RDCORINV012 Y-90 3.18E+17 156 RDCORINV013 Y-91 3.98E+18 157 RDCORINV014 Y-92 4.19E+18 158 RDCORINV015 Y-93 4.85E+18 159 RDCORINV016 Zr-95 5.38E+18 160 RDCORINV017 Zr-97 5.41E+18 161 RDCORINV018 Nb-95 5.45E+18 162 RDCORINV019 Mo-99 6.11E+18 163 RDCORINV020 Tc-99m 5.34E+18 164 RDCORINV021 Ru-103 4.89E+18 165 RDCORINV022 Ru-105 3.36E+18 166 RDCORINV023 Ru-106 1.71E+18 167 RDCORINV024 Rh-105 3.09E+18 168 RDCORINV025 Sb-127 3.47E+17 169 RDCORINV026 Sb-129 1.04E+18 170 RDCORINV027 Te-127 3.43E+17 171 RDCORINV028 Te-127m 4.50E+16 172 RDCORINV029 Te-129 1.02E+18 173 RDCORINV030 Te-129m 1.50E+17 174 RDCORINV031 Te-131m 4.64E+17 175 RDCORINV032 Te-132 4.57E+18 176 RDCORINV033 I-131 3.20E+18 177 RDCORINV034 I-132 4.64E+18 178 RDCORINV035 I-133 6.56E+18 179 RDCORINV036 I-134 7.19E+18 180 RDCORINV037 I-135 6.11E+18 181 RDCORINV038 Xe-133 6.28E+18 182 RDCORINV039 Xe-135 1.67E+18 183 RDCORINV040 Cs-134 7.19E+17 184 RDCORINV041 Cs-136 2.10E+17 185 RDCORINV042 Cs-137 4.15E+17 186 RDCORINV043 Ba-139 5.83E+18 187 RDCORINV044 Ba-140 5.62E+18
Calculation IP-CALC-09-00265, Rev. 0, Att. A.1, Page 7 188 RDCORINV045 La-140 6.04E+18 189 RDCORINV046 La-141 5.34E+18 190 RDCORINV047 La-142 5.17E+18 191 RDCORINV048 Ce-141 5.31E+18 192 RDCORINV049 Ce-143 4.96E+18 193 RDCORINV050 Ce-144 4.19E+18 194 RDCORINV051 Pr-143 4.78E+18 195 RDCORINV052 Nd-147 2.13E+18 196 RDCORINV053 Np-239 6.56E+19 197 RDCORINV054 Pu-238 1.44E+16 198 RDCORINV055 Pu-239 1.22E+15 199 RDCORINV056 Pu-240 1.83E+15 200 RDCORINV057 Pu-241 4.12E+17 201 RDCORINV058 Am-241 4.92E+14 202 RDCORINV059 Cm-242 1.23E+17 203 RDCORINV060 Cm-244 1.33E+16
- SCALING FACTOR TO ADJUST THE CORE INVENTORY FOR POWER LEVEL 204 RDCORSCA001 1.0 205 RDAPLFRC001 PARENT (apply rel fracs the same as prior versions)
- RELEASE FRACTIONS FOR ISOTOPE GROUPS IN RELEASE
- ISOTOPE GROUPS:
- Xe/Kr I Cs Te Sr Ru La Ce Ba 206 RDRELFRC001 9.3E-05 3.9E-06 1.6E-06 1.2E-06 3.7E-08 2.4E-07 2.1E-09 1.8E-08 1.1E-07
- OUTPUT CONTROL DATA BLOCK, LOADED BY INPOPT, STORED IN /STOPME/, /ATMOPT/
- FLAG TO INDICATE THAT THIS IS THE LAST PROGRAM IN THE SERIES TO BE RUN 207 OCENDAT1001 .FALSE. (SET THIS VALUE TO .TRUE. TO SKIP EARLY AND CHRONC) 208 OCIDEBUG001 0
- NAME OF THE NUCLIDE TO BE LISTED ON THE DISPERSION LISTINGS
- OCNUCOUT001 Cs-137
- NUM0 209 TYPE0NUMBER 0
- INDREL INDRAD
- TYPE0OUT001 1 9
- TYPE0OUT002 1 10 CCDF
- METEOROLOGICAL SAMPLING DATA BLOCK
- METEOROLOGICAL SAMPLING OPTION CODE:
- METCOD = 1, USER SPECIFIED DAY AND HOUR IN THE YEAR (FROM MET FILE),
- 2, WEATHER CATEGORY BIN SAMPLING,
- 3, 120 HOURS OF WEATHER SPECIFIED ON THE ATMOS USER INPUT FILE,
Calculation IP-CALC-09-00265, Rev. 0, Att. A.1, Page 8
- 4, CONSTANT MET (BOUNDARY WEATHER USED FROM THE START),
- 5, STRATIFIED RANDOM SAMPLES FOR EACH DAY OF THE YEAR.
210 M1METCOD001 2
- LAST SPATIAL INTERVAL FOR MEASURED WEATHER 211 M2LIMSPA001 15
- BOUNDARY WEATHER MIXING LAYER HEIGHT 212 M2BNDMXH001 1000. (METERS)
- BOUNDARY WEATHER STABILITY CLASS INDEX 213 M2IBDSTB001 4 (D-STABILITY)
- BOUNDARY WEATHER RAIN RATE 214 M2BNDRAN001 0. (MM/HR)
- BOUNDARY WEATHER WIND SPEED 215 M2BNDWND001 5. (M/S)
- NUMBER OF RAIN DISTANCE INTERVALS FOR BINNING 216 M4NRNINT001 6
- ENDPOINTS OF THE RAIN DISTANCE INTERVALS (KILOMETERS)
- NOTE: THESE MUST BE CHOSEN TO MATCH THE SPATIAL ENDPOINT DISTANCES
- SPECIFIED FOR THE ARRAY SPAEND (10 % ERROR IS ALLOWED).
- 2.0 4.0 7 10.0 20.0 40.0 MILES 217 M4RNDSTS001 3.23 6.45 11.29 16.13 32.26 64.52 KM
- NUMBER OF RAIN INTENSITIY BREAKPOINTS 218 M4NRINTN001 3
- RAIN INTENSITY BREAKPOINTS FOR WEATHER BINNING (MILLIMETERS PER HOUR) 219 M4RNRATE001 2. 4. 6.
- NUMBER OF SAMPLES PER BIN 220 M4NSMPLS001 4 (THIS NUMBER SHOULD BE SET TO 4 FOR RISK ASSESSMENT)
- INITIAL SEED FOR RANDOM NUMBER GENERATOR 221 M4IRSEED001 79
- TERMINATOR RECORD ENCOUNTERED -- END OF BASE CASE USER INPUT ********
USER INPUT PROCESSING
SUMMARY
- BASE CASE
Calculation IP-CALC-09-00265, Rev. 0, Att. A.1, Page 9 NUMBER OF RECORDS READ = 449 NUMBER OF BLANK OR COMMENT RECORDS READ = 227 NUMBER OF TERMINATOR RECORDS = 1 NUMBER OF RECORDS PROCESSED = 221 NUMBER OF PROCESSED RECORDS DUPLICATED = 0 NUMBER OF PROCESSED RECORDS SORTED = 221 Decay Chain # Ba-139 Decay Chain # Ba-140 La-140 Fraction of Ba-140 going to La-140 in this chain = 1.000000 Decay Chain # Ce-143 Pr-143 Fraction of Ce-143 going to Pr-143 in this chain = 1.000000 Decay Chain # Ce-144 Decay Chain # Cm-242 Pu-238 Fraction of Cm-242 going to Pu-238 in this chain = 1.000000 Decay Chain # Cm-244 Pu-240 Fraction of Cm-244 going to Pu-240 in this chain = 1.000000 Decay Chain # Co-58 Decay Chain # Co-60 Decay Chain # Cs-134 Decay Chain # Cs-136 Decay Chain # Cs-137 Decay Chain # I-133 Xe-133 Fraction of I-133 going to Xe-133 in this chain = 0.971000 Decay Chain # I-134 Decay Chain # I-135 Xe-135 Fraction of I-135 going to Xe-135 in this chain = 0.846000 Decay Chain # Kr-85m Kr-85 Fraction of Kr-85m going to Kr-85 in this chain = 0.211000 Decay Chain # Kr-87 Decay Chain # Kr-88 Decay Chain # La-141 Ce-141 Fraction of La-141 going to Ce-141 in this chain = 1.000000 Decay Chain # La-142 Decay Chain # Mo-99 Tc-99m Fraction of Mo-99 going to Tc-99m in this chain = 0.876000
Calculation IP-CALC-09-00265, Rev. 0, Att. A.1, Page 10 Decay Chain # Nd-147 Decay Chain # Np-239 Pu-239 Fraction of Np-239 going to Pu-239 in this chain = 1.000000 Decay Chain # Pu-241 Am-241 Fraction of Pu-241 going to Am-241 in this chain = 1.000000 Decay Chain # Rb-86 Decay Chain # Ru-103 Decay Chain # Ru-105 Rh-105 Fraction of Ru-105 going to Rh-105 in this chain = 1.000000 Decay Chain # Ru-106 Decay Chain # Sb-127 Te-127 Fraction of Sb-127 going to Te-127 in this chain = 0.824000 Decay Chain # Sb-127 Te-127m Te-127 Fraction of Sb-127 going to Te-127m in this chain = 0.176000 Fraction of Sb-127 going to Te-127 in this chain = 0.171776 Fraction of Te-127m going to Te-127 in this chain = 0.976000 Decay Chain # Sb-129 Te-129 Fraction of Sb-129 going to Te-129 in this chain = 0.775000 Decay Chain # Sb-129 Te-129m Te-129 Fraction of Sb-129 going to Te-129m in this chain = 0.225000 Fraction of Sb-129 going to Te-129 in this chain = 0.146250 Fraction of Te-129m going to Te-129 in this chain = 0.650000 Decay Chain # Sr-89 Decay Chain # Sr-90 Y-90 Fraction of Sr-90 going to Y-90 in this chain = 1.000000 Decay Chain # Sr-91 Y-91 Fraction of Sr-91 going to Y-91 in this chain = 0.422000 Decay Chain # Sr-92 Y-92 Fraction of Sr-92 going to Y-92 in this chain = 1.000000 Decay Chain # Te-131m I-131 Fraction of Te-131m going to I-131 in this chain = 0.778000 Decay Chain # Te-132 I-132 Fraction of Te-132 going to I-132 in this chain = 1.000000 Decay Chain # Y-93 Decay Chain # Zr-95 Nb-95 Fraction of Zr-95 going to Nb-95 in this chain = 0.993000 Decay Chain # Zr-97 RELEASED INVENTORY OF ALL PLUMES
Calculation IP-CALC-09-00265, Rev. 0, Att. A.1, Page 11 Co-58 7.26E+09 Co-60 5.57E+09 Kr-85 3.57E+12 Kr-85m 1.23E+13 Kr-87 2.19E+11 Kr-88 1.14E+13 Rb-86 1.31E+10 Sr-89 1.13E+11 Sr-90 1.13E+10 Sr-91 5.97E+10 Sr-92 7.20E+09 Y-90 1.96E+09 Y-91 8.55E+09 Y-92 2.56E+10 Y-93 4.47E+09 Zr-95 1.12E+10 Zr-97 6.94E+09 Nb-95 1.14E+10 Mo-99 1.29E+12 Tc-99m 1.21E+12 Ru-103 1.16E+12 Ru-105 1.24E+11 Ru-106 4.10E+11 Rh-105 6.60E+11 Sb-127 3.81E+11 Sb-129 1.82E+11 Te-127 3.92E+11 Te-127m 5.41E+10 Te-129 3.09E+11 Te-129m 1.79E+11 Te-131m 4.22E+11 Te-132 4.93E+12 I-131 1.20E+13 I-132 5.41E+12 I-133 1.72E+13 I-134 2.12E+09 I-135 6.77E+12 Xe-133 5.48E+14 Xe-135 6.85E+13 Cs-134 1.15E+12 Cs-136 3.27E+11 Cs-137 6.64E+11 Ba-139 1.54E+09 Ba-140 6.02E+11 La-140 1.24E+11 La-141 1.35E+09 La-142 4.93E+07 Ce-141 9.46E+10 Ce-143 6.94E+10 Ce-144 7.53E+10 Pr-143 1.18E+10 Nd-147 4.33E+09 Np-239 1.02E+12 Pu-238 2.59E+08 Pu-239 2.20E+07 Pu-240 3.29E+07 Pu-241 7.42E+09 Am-241 1.05E+06 Cm-242 2.58E+08
Calculation IP-CALC-09-00265, Rev. 0, Att. A.1, Page 12 Cm-244 2.79E+07 READING FROM A WEATHER FILE WITH THE FOLLOWING HEADER:
INDIAN POINT ENERGY CENTER METEORLOGICAL DATAFILE Input file for the MACCS2 model using the year 2000 METEOROLOGICAL DATA FILE CONTAINS 397 HOURS OF OBSERVED RAIN DATA.
ACCUMULATED RAIN MEASUREMENTS TOTALED 30.31 INCHES FOR THE YEAR.
CONSTANT LID HEIGHTS (M) FOR 4 SEASONS = 1100 1500 1500 1300 NON-ZERO WINDSPEEDS LESS THAN 0.5 M/S ARE SET TO 0.5 M/S NUMTRI= 155
- * *
- METEOROLOGICAL BIN
SUMMARY
BIN PRIORITIES RI XX - RAIN INTENSITY I WITHIN THE INTERVAL ENDING AT XX INTERVAL ENDPOINTS ARE IN KILOMETERS FROM THE ACCIDENT SITE, THE 6 INTERVAL ENDPOINTS ARE 3 6 11 16 32 65 RAIN INTENSITIES ARE IN MILLIMETERS OF RAIN PER HOUR, THE 3 INTENSITY BREAKPOINTS ARE 2.0 4.0 6.0 S V - INITIAL WEATHER CONDITIONS WITH STABILITY CLASS S AND WIND SPEED INTERVAL V STABILITY CLASSES ARE B = A/B, D = C/D, E = E, AND F = F WIND SPEED INTERVALS ARE IN METERS PER SECOND, 1 (0-1), 2 (1-2), 3 (2-3), 4 (3-5), 5 (5-7), 6 (GT 7)
WIND DIRECTION METBIN 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 TOTAL PER CENT 1 B 3 0.083 0.009 0.009 0.092 0.083 0.128 0.165 0.174 0.092 0.000 0.009 0.000 0.000 0.009 0.000 0.147 109 1.2443 2 B 4 0.066 0.033 0.022 0.000 0.022 0.044 0.154 0.077 0.275 0.055 0.000 0.000 0.000 0.000 0.000 0.253 91 1.0388 3 D 1 0.115 0.073 0.055 0.032 0.009 0.014 0.005 0.023 0.032 0.064 0.060 0.064 0.115 0.101 0.142 0.096 218 2.4886 4 D 2 0.158 0.092 0.041 0.049 0.047 0.039 0.046 0.063 0.109 0.113 0.071 0.043 0.020 0.012 0.025 0.071 1377 15.7192 5 D 3 0.124 0.047 0.021 0.033 0.067 0.107 0.099 0.102 0.192 0.125 0.029 0.004 0.002 0.000 0.003 0.046 1699 19.3950 6 D 4 0.075 0.020 0.007 0.011 0.040 0.129 0.191 0.111 0.223 0.138 0.017 0.001 0.000 0.000 0.001 0.036 1453 16.5868 7 D 5 0.055 0.021 0.014 0.000 0.021 0.034 0.274 0.068 0.342 0.144 0.000 0.000 0.000 0.000 0.000 0.027 146 1.6667 8 D 6 0.000 0.000 0.000 0.000 0.200 0.000 0.000 0.200 0.400 0.200 0.000 0.000 0.000 0.000 0.000 0.000 5 0.0571 9 E 1 0.118 0.087 0.076 0.037 0.022 0.028 0.024 0.031 0.081 0.109 0.061 0.059 0.041 0.072 0.081 0.076 543 6.1986 10 E 2 0.188 0.094 0.065 0.026 0.017 0.007 0.009 0.010 0.047 0.190 0.163 0.051 0.024 0.010 0.013 0.087 898 10.2511 11 E 3 0.227 0.054 0.003 0.003 0.007 0.007 0.003 0.014 0.044 0.424 0.163 0.003 0.000 0.000 0.000 0.047 295 3.3676 12 E 4 0.298 0.053 0.035 0.000 0.000 0.018 0.000 0.018 0.246 0.211 0.035 0.000 0.000 0.000 0.000 0.088 57 0.6507 13 F 1 0.051 0.017 0.039 0.000 0.022 0.034 0.045 0.090 0.225 0.208 0.073 0.056 0.034 0.011 0.045 0.051 178 2.0320 14 F 2 0.017 0.008 0.008 0.004 0.008 0.000 0.000 0.004 0.054 0.675 0.171 0.033 0.004 0.004 0.000 0.008 240 2.7397 15 F 3 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.707 0.276 0.000 0.000 0.000 0.000 0.017 58 0.6621 16 F 4 0.143 0.000 0.000 0.000 0.000 0.143 0.000 0.000 0.000 0.429 0.286 0.000 0.000 0.000 0.000 0.000 7 0.0799 17 R1 3 0.107 0.017 0.014 0.014 0.007 0.031 0.034 0.038 0.214 0.259 0.055 0.034 0.041 0.045 0.034 0.055 290 3.3105 18 R1 6 0.149 0.043 0.021 0.000 0.000 0.000 0.000 0.000 0.106 0.106 0.085 0.128 0.128 0.085 0.043 0.106 47 0.5365 19 R1 11 0.095 0.053 0.032 0.000 0.000 0.042 0.011 0.021 0.084 0.253 0.074 0.074 0.074 0.021 0.063 0.105 95 1.0845 20 R1 16 0.192 0.041 0.000 0.014 0.014 0.027 0.014 0.055 0.110 0.164 0.055 0.055 0.027 0.082 0.041 0.110 73 0.8333 21 R1 32 0.149 0.035 0.045 0.015 0.005 0.040 0.005 0.015 0.069 0.243 0.099 0.050 0.035 0.030 0.020 0.149 202 2.3059 22 R1 65 0.124 0.074 0.029 0.021 0.018 0.029 0.003 0.029 0.115 0.203 0.109 0.029 0.026 0.035 0.021 0.135 340 3.8813 23 R2 3 0.108 0.031 0.000 0.015 0.031 0.000 0.015 0.046 0.231 0.277 0.062 0.046 0.015 0.046 0.000 0.077 65 0.7420 24 R2 6 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.200 0.000 0.000 0.000 0.000 0.200 0.400 0.200 5 0.0571 25 R2 11 0.214 0.071 0.000 0.000 0.000 0.000 0.000 0.071 0.071 0.143 0.000 0.000 0.000 0.000 0.071 0.357 14 0.1598 26 R2 16 0.429 0.143 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.143 0.000 0.000 0.000 0.000 0.143 0.143 7 0.0799 27 R2 32 0.263 0.211 0.000 0.000 0.000 0.000 0.000 0.000 0.053 0.211 0.053 0.000 0.053 0.000 0.053 0.105 19 0.2169 28 R2 65 0.233 0.047 0.070 0.023 0.000 0.000 0.000 0.000 0.070 0.163 0.116 0.023 0.023 0.023 0.093 0.116 43 0.4909 29 R3 3 0.143 0.048 0.048 0.000 0.048 0.000 0.000 0.000 0.095 0.286 0.048 0.095 0.048 0.048 0.000 0.095 21 0.2397 30 R3 6 0.250 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.250 0.250 0.000 0.000 0.250 4 0.0457 31 R3 11 0.000 0.286 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.286 0.143 0.286 7 0.0799 32 R3 16 0.500 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.500 0.000 2 0.0228 33 R3 32 0.214 0.357 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.071 0.000 0.000 0.071 0.143 0.000 0.143 14 0.1598 34 R3 65 0.276 0.138 0.000 0.000 0.034 0.000 0.000 0.034 0.034 0.172 0.069 0.000 0.034 0.000 0.000 0.207 29 0.3311 35 R4 3 0.133 0.033 0.000 0.033 0.000 0.033 0.000 0.000 0.033 0.300 0.033 0.067 0.067 0.067 0.100 0.100 30 0.3425
Calculation IP-CALC-09-00265, Rev. 0, Att. A.1, Page 13 36 R4 6 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 1.000 1 0.0114 37 R4 11 0.200 0.300 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.200 0.100 0.000 0.100 0.000 0.000 0.100 10 0.1142 38 R4 16 0.000 0.000 0.167 0.167 0.000 0.000 0.000 0.000 0.000 0.333 0.167 0.000 0.000 0.000 0.167 0.000 6 0.0685 39 R4 32 0.227 0.045 0.091 0.136 0.000 0.045 0.000 0.045 0.045 0.227 0.045 0.000 0.000 0.000 0.000 0.091 22 0.2511 40 R4 65 0.400 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.150 0.300 0.025 0.000 0.000 0.000 0.000 0.125 40 0.4566 41 ALL 0.128 0.056 0.030 0.025 0.035 0.059 0.072 0.063 0.140 0.174 0.068 0.027 0.018 0.017 0.021 0.069 8760
Calculation IP-CALC-09-00265, Rev. 0, Att. A.1, Page 14
- * *
- METEOROLOGICAL BIN
SUMMARY
BIN PRIORITIES RI XX - RAIN INTENSITY I WITHIN THE INTERVAL ENDING AT XX INTERVAL ENDPOINTS ARE IN KILOMETERS FROM THE ACCIDENT SITE, THE 6 INTERVAL ENDPOINTS ARE 3 6 11 16 32 65 RAIN INTENSITIES ARE IN MILLIMETERS OF RAIN PER HOUR, THE 3 INTENSITY BREAKPOINTS ARE 2.0 4.0 6.0 S V - INITIAL WEATHER CONDITIONS WITH STABILITY CLASS S AND WIND SPEED INTERVAL V STABILITY CLASSES ARE B = A/B, D = C/D, E = E, AND F = F WIND SPEED INTERVALS ARE IN METERS PER SECOND (M/S), 1 (0-1), 2 (1-2), 3 (2-3), 4 (3-5), 5 (5-7), 6 (GT 7)
WIND DIRECTION METBIN 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 TOTAL PER CENT 1 B 3 9 1 1 10 9 14 18 19 10 0 1 0 0 1 0 16 109 1.2443 2 B 4 6 3 2 0 2 4 14 7 25 5 0 0 0 0 0 23 91 1.0388 3 D 1 25 16 12 7 2 3 1 5 7 14 13 14 25 22 31 21 218 2.4886 4 D 2 218 127 57 67 65 54 64 87 150 155 98 59 27 16 35 98 1377 15.7192 5 D 3 210 80 35 56 114 181 168 174 326 213 49 7 3 0 5 78 1699 19.3950 6 D 4 109 29 10 16 58 187 278 162 324 201 25 1 0 0 1 52 1453 16.5868 7 D 5 8 3 2 0 3 5 40 10 50 21 0 0 0 0 0 4 146 1.6667 8 D 6 0 0 0 0 1 0 0 1 2 1 0 0 0 0 0 0 5 0.0571 9 E 1 64 47 41 20 12 15 13 17 44 59 33 32 22 39 44 41 543 6.1986 10 E 2 169 84 58 23 15 6 8 9 42 171 146 46 22 9 12 78 898 10.2511 11 E 3 67 16 1 1 2 2 1 4 13 125 48 1 0 0 0 14 295 3.3676 12 E 4 17 3 2 0 0 1 0 1 14 12 2 0 0 0 0 5 57 0.6507 13 F 1 9 3 7 0 4 6 8 16 40 37 13 10 6 2 8 9 178 2.0320 14 F 2 4 2 2 1 2 0 0 1 13 162 41 8 1 1 0 2 240 2.7397 15 F 3 0 0 0 0 0 0 0 0 0 41 16 0 0 0 0 1 58 0.6621 16 F 4 1 0 0 0 0 1 0 0 0 3 2 0 0 0 0 0 7 0.0799 17 R1 3 31 5 4 4 2 9 10 11 62 75 16 10 12 13 10 16 290 3.3105 18 R1 6 7 2 1 0 0 0 0 0 5 5 4 6 6 4 2 5 47 0.5365 19 R1 11 9 5 3 0 0 4 1 2 8 24 7 7 7 2 6 10 95 1.0845 20 R1 16 14 3 0 1 1 2 1 4 8 12 4 4 2 6 3 8 73 0.8333 21 R1 32 30 7 9 3 1 8 1 3 14 49 20 10 7 6 4 30 202 2.3059 22 R1 65 42 25 10 7 6 10 1 10 39 69 37 10 9 12 7 46 340 3.8813 23 R2 3 7 2 0 1 2 0 1 3 15 18 4 3 1 3 0 5 65 0.7420 24 R2 6 0 0 0 0 0 0 0 0 1 0 0 0 0 1 2 1 5 0.0571 25 R2 11 3 1 0 0 0 0 0 1 1 2 0 0 0 0 1 5 14 0.1598 26 R2 16 3 1 0 0 0 0 0 0 0 1 0 0 0 0 1 1 7 0.0799 27 R2 32 5 4 0 0 0 0 0 0 1 4 1 0 1 0 1 2 19 0.2169 28 R2 65 10 2 3 1 0 0 0 0 3 7 5 1 1 1 4 5 43 0.4909 29 R3 3 3 1 1 0 1 0 0 0 2 6 1 2 1 1 0 2 21 0.2397 30 R3 6 1 0 0 0 0 0 0 0 0 0 0 1 1 0 0 1 4 0.0457 31 R3 11 0 2 0 0 0 0 0 0 0 0 0 0 0 2 1 2 7 0.0799 32 R3 16 1 0 0 0 0 0 0 0 0 0 0 0 0 0 1 0 2 0.0228 33 R3 32 3 5 0 0 0 0 0 0 0 1 0 0 1 2 0 2 14 0.1598 34 R3 65 8 4 0 0 1 0 0 1 1 5 2 0 1 0 0 6 29 0.3311 35 R4 3 4 1 0 1 0 1 0 0 1 9 1 2 2 2 3 3 30 0.3425 36 R4 6 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1 1 0.0114 37 R4 11 2 3 0 0 0 0 0 0 0 2 1 0 1 0 0 1 10 0.1142 38 R4 16 0 0 1 1 0 0 0 0 0 2 1 0 0 0 1 0 6 0.0685 39 R4 32 5 1 2 3 0 1 0 1 1 5 1 0 0 0 0 2 22 0.2511 40 R4 65 16 0 0 0 0 0 0 0 6 12 1 0 0 0 0 5 40 0.4566
- * *
- SUMMARIES * * *
- R 204 74 34 22 14 35 15 36 168 308 106 56 53 55 47 159 1386 15.8219 B 15 4 3 10 11 18 32 26 35 5 1 0 0 1 0 39 200 2.2831
Calculation IP-CALC-09-00265, Rev. 0, Att. A.1, Page 15 D 570 255 116 146 243 430 551 439 859 605 185 81 55 38 72 253 4898 55.9132 E 317 150 102 44 29 24 22 31 113 367 229 79 44 48 56 138 1793 20.4680 F 14 5 9 1 6 7 8 17 53 243 72 18 7 3 8 12 483 5.5137 1 98 66 60 27 18 24 22 38 91 110 59 56 53 63 83 71 939 10.7192 2 391 213 117 92 83 60 78 101 206 488 286 113 50 26 47 180 2531 28.8927 3 286 97 37 66 124 197 181 193 348 379 113 8 3 1 5 107 2145 24.4863 4 132 34 14 16 60 193 292 170 360 221 29 1 0 0 1 79 1602 18.2877 5 9 4 2 0 3 5 40 10 53 21 0 0 0 0 0 5 152 1.7352 6 0 0 0 0 1 0 0 1 2 1 0 0 0 0 0 0 5 0.0571
Calculation IP-CALC-09-00265, Rev. 0, Att. A.1, Page 16
- * * *
- BIN WINDROSE
SUMMARY
BIN DIRECTION TOTAL 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 1 0.083 0.009 0.009 0.092 0.083 0.128 0.165 0.174 0.092 0.000 0.009 0.000 0.000 0.009 0.000 0.147 1.000000 2 0.066 0.033 0.022 0.000 0.022 0.044 0.154 0.077 0.275 0.055 0.000 0.000 0.000 0.000 0.000 0.253 1.000000 3 0.115 0.073 0.055 0.032 0.009 0.014 0.005 0.023 0.032 0.064 0.060 0.064 0.115 0.101 0.142 0.096 1.000000 4 0.158 0.092 0.041 0.049 0.047 0.039 0.046 0.063 0.109 0.113 0.071 0.043 0.020 0.012 0.025 0.071 1.000000 5 0.124 0.047 0.021 0.033 0.067 0.107 0.099 0.102 0.192 0.125 0.029 0.004 0.002 0.000 0.003 0.046 1.000000 6 0.075 0.020 0.007 0.011 0.040 0.129 0.191 0.111 0.223 0.138 0.017 0.001 0.000 0.000 0.001 0.036 1.000000 7 0.055 0.021 0.014 0.000 0.021 0.034 0.274 0.068 0.342 0.144 0.000 0.000 0.000 0.000 0.000 0.027 1.000000 8 0.000 0.000 0.000 0.000 0.200 0.000 0.000 0.200 0.400 0.200 0.000 0.000 0.000 0.000 0.000 0.000 1.000000 9 0.118 0.087 0.076 0.037 0.022 0.028 0.024 0.031 0.081 0.109 0.061 0.059 0.041 0.072 0.081 0.076 1.000000 10 0.188 0.094 0.065 0.026 0.017 0.007 0.009 0.010 0.047 0.190 0.163 0.051 0.024 0.010 0.013 0.087 1.000000 11 0.227 0.054 0.003 0.003 0.007 0.007 0.003 0.014 0.044 0.424 0.163 0.003 0.000 0.000 0.000 0.047 1.000000 12 0.298 0.053 0.035 0.000 0.000 0.018 0.000 0.018 0.246 0.211 0.035 0.000 0.000 0.000 0.000 0.088 1.000000 13 0.051 0.017 0.039 0.000 0.022 0.034 0.045 0.090 0.225 0.208 0.073 0.056 0.034 0.011 0.045 0.051 1.000000 14 0.017 0.008 0.008 0.004 0.008 0.000 0.000 0.004 0.054 0.675 0.171 0.033 0.004 0.004 0.000 0.008 1.000000 15 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.707 0.276 0.000 0.000 0.000 0.000 0.017 1.000000 16 0.143 0.000 0.000 0.000 0.000 0.143 0.000 0.000 0.000 0.429 0.286 0.000 0.000 0.000 0.000 0.000 1.000000 17 0.147 0.053 0.025 0.016 0.010 0.025 0.011 0.026 0.121 0.222 0.076 0.040 0.038 0.040 0.034 0.115 1.000000 18 0.147 0.053 0.025 0.016 0.010 0.025 0.011 0.026 0.121 0.222 0.076 0.040 0.038 0.040 0.034 0.115 1.000000 19 0.147 0.053 0.025 0.016 0.010 0.025 0.011 0.026 0.121 0.222 0.076 0.040 0.038 0.040 0.034 0.115 1.000000 20 0.147 0.053 0.025 0.016 0.010 0.025 0.011 0.026 0.121 0.222 0.076 0.040 0.038 0.040 0.034 0.115 1.000000 21 0.147 0.053 0.025 0.016 0.010 0.025 0.011 0.026 0.121 0.222 0.076 0.040 0.038 0.040 0.034 0.115 1.000000 22 0.147 0.053 0.025 0.016 0.010 0.025 0.011 0.026 0.121 0.222 0.076 0.040 0.038 0.040 0.034 0.115 1.000000 23 0.147 0.053 0.025 0.016 0.010 0.025 0.011 0.026 0.121 0.222 0.076 0.040 0.038 0.040 0.034 0.115 1.000000 24 0.147 0.053 0.025 0.016 0.010 0.025 0.011 0.026 0.121 0.222 0.076 0.040 0.038 0.040 0.034 0.115 1.000000 25 0.147 0.053 0.025 0.016 0.010 0.025 0.011 0.026 0.121 0.222 0.076 0.040 0.038 0.040 0.034 0.115 1.000000 26 0.147 0.053 0.025 0.016 0.010 0.025 0.011 0.026 0.121 0.222 0.076 0.040 0.038 0.040 0.034 0.115 1.000000 27 0.147 0.053 0.025 0.016 0.010 0.025 0.011 0.026 0.121 0.222 0.076 0.040 0.038 0.040 0.034 0.115 1.000000 28 0.147 0.053 0.025 0.016 0.010 0.025 0.011 0.026 0.121 0.222 0.076 0.040 0.038 0.040 0.034 0.115 1.000000 29 0.147 0.053 0.025 0.016 0.010 0.025 0.011 0.026 0.121 0.222 0.076 0.040 0.038 0.040 0.034 0.115 1.000000 30 0.147 0.053 0.025 0.016 0.010 0.025 0.011 0.026 0.121 0.222 0.076 0.040 0.038 0.040 0.034 0.115 1.000000 31 0.147 0.053 0.025 0.016 0.010 0.025 0.011 0.026 0.121 0.222 0.076 0.040 0.038 0.040 0.034 0.115 1.000000 32 0.147 0.053 0.025 0.016 0.010 0.025 0.011 0.026 0.121 0.222 0.076 0.040 0.038 0.040 0.034 0.115 1.000000 33 0.147 0.053 0.025 0.016 0.010 0.025 0.011 0.026 0.121 0.222 0.076 0.040 0.038 0.040 0.034 0.115 1.000000 34 0.147 0.053 0.025 0.016 0.010 0.025 0.011 0.026 0.121 0.222 0.076 0.040 0.038 0.040 0.034 0.115 1.000000 35 0.147 0.053 0.025 0.016 0.010 0.025 0.011 0.026 0.121 0.222 0.076 0.040 0.038 0.040 0.034 0.115 1.000000 36 0.147 0.053 0.025 0.016 0.010 0.025 0.011 0.026 0.121 0.222 0.076 0.040 0.038 0.040 0.034 0.115 1.000000 37 0.147 0.053 0.025 0.016 0.010 0.025 0.011 0.026 0.121 0.222 0.076 0.040 0.038 0.040 0.034 0.115 1.000000 38 0.147 0.053 0.025 0.016 0.010 0.025 0.011 0.026 0.121 0.222 0.076 0.040 0.038 0.040 0.034 0.115 1.000000 39 0.147 0.053 0.025 0.016 0.010 0.025 0.011 0.026 0.121 0.222 0.076 0.040 0.038 0.040 0.034 0.115 1.000000 40 0.147 0.053 0.025 0.016 0.010 0.025 0.011 0.026 0.121 0.222 0.076 0.040 0.038 0.040 0.034 0.115 1.000000 41 0.128 0.056 0.030 0.025 0.035 0.059 0.072 0.063 0.140 0.174 0.068 0.027 0.018 0.017 0.021 0.069 1.000000
- BEGINNING OF CHANGE CASE 1 USER INPUT ********
- RELEASE DATA BLOCK *************
- SOURCE TERM NUMBER 2 OF 8 222 RDATNAM2001 'EARLY HIGH'
- RECORD NUMBER 222 REPLACES RECORD NUMBER 123 ********
223 RDOALARM001 1.36E+04
- RECORD NUMBER 223 REPLACES RECORD NUMBER 124 ********
224 RDNUMREL001 1
- RECORD NUMBER 224 REPLACES RECORD NUMBER 125 ********
225 RDMAXRIS001 1
Calculation IP-CALC-09-00265, Rev. 0, Att. A.1, Page 17
- RECORD NUMBER 225 REPLACES RECORD NUMBER 126 ********
226 RDREFTIM001 0.0
- RECORD NUMBER 226 REPLACES RECORD NUMBER 127 ********
227 RDPLHEAT001 1.08E+06
- RECORD NUMBER 227 REPLACES RECORD NUMBER 128 ********
228 RDPLHITE001 30.
- RECORD NUMBER 228 REPLACES RECORD NUMBER 129 ********
229 RDPLUDUR001 8.24E+04
- RECORD NUMBER 229 REPLACES RECORD NUMBER 130 ********
230 RDPDELAY001 1.32E+04
- RECORD NUMBER 230 REPLACES RECORD NUMBER 131 ********
- Xe/Kr I Cs Te Sr Ru La Ce Ba 231 RDRELFRC001 7.0E-01 2.4E-01 2.3E-01 2.3E-01 2.5E-02 9.1E-02 8.0E-04 4.8E-03 4.6E-02
- RECORD NUMBER 231 REPLACES RECORD NUMBER 206 ********
- TERMINATOR RECORD ENCOUNTERED -- END OF CHANGE CASE 1 USER INPUT ********
USER INPUT PROCESSING
SUMMARY
- CHANGE CASE 1 NUMBER OF RECORDS CHANGED = 10 NUMBER OF RECORDS ADDED = 0 RELEASED INVENTORY OF ALL PLUMES Co-58 2.76E+15 Co-60 2.11E+15 Kr-85 2.69E+16 Kr-85m 3.37E+17 Kr-87 1.55E+17 Kr-88 6.55E+17 Rb-86 1.90E+15 Sr-89 7.68E+16 Sr-90 7.62E+15 Sr-91 7.40E+16 Sr-92 4.10E+16 Y-90 5.41E+14 Y-91 3.24E+15 Y-92 3.46E+16 Y-93 3.02E+15 Zr-95 4.30E+15 Zr-97 3.72E+15 Nb-95 4.36E+15 Mo-99 5.35E+17 Tc-99m 4.83E+17 Ru-103 4.44E+17 Ru-105 1.72E+17 Ru-106 1.56E+17 Rh-105 2.78E+17 Sb-127 7.76E+16 Sb-129 1.33E+17 Te-127 7.79E+16 Te-127m 1.04E+16 Te-129 1.59E+17 Te-129m 3.45E+16 Te-131m 9.81E+16 Te-132 1.02E+18
Calculation IP-CALC-09-00265, Rev. 0, Att. A.1, Page 18 I-131 7.59E+17 I-132 1.06E+18 I-133 1.39E+18 I-134 9.50E+16 I-135 9.98E+17 Xe-133 4.34E+18 Xe-135 1.13E+18 Cs-134 1.65E+17 Cs-136 4.79E+16 Cs-137 9.54E+16 Ba-139 4.24E+16 Ba-140 2.56E+17 La-140 2.03E+16 La-141 2.24E+15 La-142 7.95E+14 Ce-141 2.54E+16 Ce-143 2.20E+16 Ce-144 2.01E+16 Pr-143 3.97E+15 Nd-147 1.69E+15 Np-239 3.01E+17 Pu-238 6.91E+13 Pu-239 5.86E+12 Pu-240 8.78E+12 Pu-241 1.98E+15 Am-241 3.95E+11 Cm-242 9.83E+13 Cm-244 1.06E+13
- BEGINNING OF CHANGE CASE 2 USER INPUT ********
- RELEASE DATA BLOCK *************
- SOURCE TERM NUMBER 3 OF 8 232 RDATNAM2001 'EARLY MEDIUM'
- RECORD NUMBER 232 REPLACES RECORD NUMBER 123 ********
233 RDOALARM001 1.00E+04
- RECORD NUMBER 233 REPLACES RECORD NUMBER 124 ********
234 RDNUMREL001 1
- RECORD NUMBER 234 REPLACES RECORD NUMBER 125 ********
235 RDMAXRIS001 1
- RECORD NUMBER 235 REPLACES RECORD NUMBER 126 ********
236 RDREFTIM001 0.0
- RECORD NUMBER 236 REPLACES RECORD NUMBER 127 ********
237 RDPLHEAT001 1.33E+06
- RECORD NUMBER 237 REPLACES RECORD NUMBER 128 ********
238 RDPLHITE001 30.
- RECORD NUMBER 238 REPLACES RECORD NUMBER 129 ********
239 RDPLUDUR001 8.64E+04
- RECORD NUMBER 239 REPLACES RECORD NUMBER 130 ********
240 RDPDELAY001 1.25E+04
- RECORD NUMBER 240 REPLACES RECORD NUMBER 131 ********
- Xe/Kr I Cs Te Sr Ru La Ce Ba 241 RDRELFRC001 9.9E-01 2.0E-02 1.8E-02 2.7E-02 8.3E-04 2.0E-02 4.9E-05 3.3E-04 1.3E-02
- RECORD NUMBER 241 REPLACES RECORD NUMBER 206 ********
- TERMINATOR RECORD ENCOUNTERED -- END OF CHANGE CASE 2 USER INPUT ********
Calculation IP-CALC-09-00265, Rev. 0, Att. A.1, Page 19 USER INPUT PROCESSING
SUMMARY
- CHANGE CASE 2 NUMBER OF RECORDS CHANGED = 10 NUMBER OF RECORDS ADDED = 0 RELEASED INVENTORY OF ALL PLUMES Co-58 6.07E+14 Co-60 4.64E+14 Kr-85 3.80E+16 Kr-85m 4.91E+17 Kr-87 2.43E+17 Kr-88 9.71E+17 Rb-86 1.49E+14 Sr-89 2.55E+15 Sr-90 2.53E+14 Sr-91 2.49E+15 Sr-92 1.43E+15 Y-90 2.43E+13 Y-91 1.97E+14 Y-92 1.19E+15 Y-93 1.87E+14 Zr-95 2.63E+14 Zr-97 2.30E+14 Nb-95 2.67E+14 Mo-99 1.18E+17 Tc-99m 1.06E+17 Ru-103 9.76E+16 Ru-105 3.91E+16 Ru-106 3.42E+16 Rh-105 6.11E+16 Sb-127 9.13E+15 Sb-129 1.61E+16 Te-127 9.16E+15 Te-127m 1.22E+15 Te-129 1.91E+16 Te-129m 4.05E+15 Te-131m 1.16E+16 Te-132 1.20E+17 I-131 6.33E+16 I-132 1.11E+17 I-133 1.17E+17 I-134 9.24E+15 I-135 8.49E+16 Xe-133 6.10E+18 Xe-135 1.29E+18 Cs-134 1.29E+16 Cs-136 3.75E+15 Cs-137 7.47E+15 Ba-139 1.32E+16 Ba-140 7.25E+16 La-140 4.50E+15 La-141 1.42E+14 La-142 5.32E+13 Ce-141 1.75E+15 Ce-143 1.52E+15
Calculation IP-CALC-09-00265, Rev. 0, Att. A.1, Page 20 Ce-144 1.38E+15 Pr-143 2.44E+14 Nd-147 1.03E+14 Np-239 2.07E+16 Pu-238 4.75E+12 Pu-239 4.03E+11 Pu-240 6.04E+11 Pu-241 1.36E+14 Am-241 2.42E+10 Cm-242 6.02E+12 Cm-244 6.52E+11
- BEGINNING OF CHANGE CASE 3 USER INPUT ********
- RELEASE DATA BLOCK *************
- SOURCE TERM NUMBER 4 OF 8 242 RDATNAM2001 'EARLY LOW'
- RECORD NUMBER 242 REPLACES RECORD NUMBER 123 ********
243 RDOALARM001 1.09E+04
- RECORD NUMBER 243 REPLACES RECORD NUMBER 124 ********
244 RDNUMREL001 1
- RECORD NUMBER 244 REPLACES RECORD NUMBER 125 ********
245 RDMAXRIS001 1
- RECORD NUMBER 245 REPLACES RECORD NUMBER 126 ********
246 RDREFTIM001 0.0
- RECORD NUMBER 246 REPLACES RECORD NUMBER 127 ********
247 RDPLHEAT001 1.60E+06
- RECORD NUMBER 247 REPLACES RECORD NUMBER 128 ********
248 RDPLHITE001 30.
- RECORD NUMBER 248 REPLACES RECORD NUMBER 129 ********
249 RDPLUDUR001 8.64E+04
- RECORD NUMBER 249 REPLACES RECORD NUMBER 130 ********
250 RDPDELAY001 1.73E+04
- RECORD NUMBER 250 REPLACES RECORD NUMBER 131 ********
- Xe/Kr I Cs Te Sr Ru La Ce Ba 251 RDRELFRC001 7.6E-01 5.9E-03 4.1E-03 3.9E-03 1.0E-04 2.0E-03 4.6E-06 3.3E-05 7.8E-04
- RECORD NUMBER 251 REPLACES RECORD NUMBER 206 ********
- TERMINATOR RECORD ENCOUNTERED -- END OF CHANGE CASE 3 USER INPUT ********
USER INPUT PROCESSING
SUMMARY
- CHANGE CASE 3 NUMBER OF RECORDS CHANGED = 10 NUMBER OF RECORDS ADDED = 0 RELEASED INVENTORY OF ALL PLUMES Co-58 6.07E+13 Co-60 4.64E+13 Kr-85 2.92E+16 Kr-85m 3.06E+17 Kr-87 9.02E+16 Kr-88 5.39E+17 Rb-86 3.38E+13
Calculation IP-CALC-09-00265, Rev. 0, Att. A.1, Page 21 Sr-89 3.07E+14 Sr-90 3.05E+13 Sr-91 2.73E+14 Sr-92 1.23E+14 Y-90 2.94E+12 Y-91 1.86E+13 Y-92 1.41E+14 Y-93 1.60E+13 Zr-95 2.47E+13 Zr-97 2.04E+13 Nb-95 2.51E+13 Mo-99 1.16E+16 Tc-99m 1.06E+16 Ru-103 9.75E+15 Ru-105 3.17E+15 Ru-106 3.42E+15 Rh-105 6.05E+15 Sb-127 1.31E+15 Sb-129 1.88E+15 Te-127 1.32E+15 Te-127m 1.76E+14 Te-129 2.33E+15 Te-129m 5.85E+14 Te-131m 1.62E+15 Te-132 1.71E+16 I-131 1.86E+16 I-132 1.97E+16 I-133 3.30E+16 I-134 9.49E+14 I-135 2.18E+16 Xe-133 4.65E+18 Xe-135 8.87E+17 Cs-134 2.95E+15 Cs-136 8.52E+14 Cs-137 1.70E+15 Ba-139 4.06E+14 Ba-140 4.34E+15 La-140 3.72E+14 La-141 1.05E+13 La-142 2.74E+12 Ce-141 1.75E+14 Ce-143 1.48E+14 Ce-144 1.38E+14 Pr-143 2.33E+13 Nd-147 9.67E+12 Np-239 2.04E+15 Pu-238 4.75E+11 Pu-239 4.03E+10 Pu-240 6.04E+10 Pu-241 1.36E+13 Am-241 2.28E+09 Cm-242 5.65E+11 Cm-244 6.12E+10
- BEGINNING OF CHANGE CASE 4 USER INPUT ********
- RELEASE DATA BLOCK *************
- SOURCE TERM NUMBER 5 OF 8
Calculation IP-CALC-09-00265, Rev. 0, Att. A.1, Page 22 252 RDATNAM2001 'LATE HIGH'
- RECORD NUMBER 252 REPLACES RECORD NUMBER 123 ********
253 RDOALARM001 5.58E+03
- RECORD NUMBER 253 REPLACES RECORD NUMBER 124 ********
254 RDNUMREL001 1
- RECORD NUMBER 254 REPLACES RECORD NUMBER 125 ********
255 RDMAXRIS001 1
- RECORD NUMBER 255 REPLACES RECORD NUMBER 126 ********
256 RDREFTIM001 0.5
- RECORD NUMBER 256 REPLACES RECORD NUMBER 127 ********
257 RDPLHEAT001 9.20E+05
- RECORD NUMBER 257 REPLACES RECORD NUMBER 128 ********
258 RDPLHITE001 30.
- RECORD NUMBER 258 REPLACES RECORD NUMBER 129 ********
259 RDPLUDUR001 8.64E+04
- RECORD NUMBER 259 REPLACES RECORD NUMBER 130 ********
260 RDPDELAY001 7.38E+04
- RECORD NUMBER 260 REPLACES RECORD NUMBER 131 ********
- Xe/Kr I Cs Te Sr Ru La Ce Ba 261 RDRELFRC001 9.9E-01 1.2E-01 2.3E-02 4.8E-03 2.1E-04 3.7E-03 1.3E-05 1.2E-04 9.1E-04
- RECORD NUMBER 261 REPLACES RECORD NUMBER 206 ********
- TERMINATOR RECORD ENCOUNTERED -- END OF CHANGE CASE 4 USER INPUT ********
USER INPUT PROCESSING
SUMMARY
- CHANGE CASE 4 NUMBER OF RECORDS CHANGED = 10 NUMBER OF RECORDS ADDED = 0 RELEASED INVENTORY OF ALL PLUMES Co-58 1.11E+14 Co-60 8.58E+13 Kr-85 3.80E+16 Kr-85m 5.50E+15 Kr-87 3.27E+10 Kr-88 8.14E+14 Rb-86 1.82E+14 Sr-89 6.35E+14 Sr-90 6.40E+13 Sr-91 7.59E+13 Sr-92 2.16E+11 Y-90 2.19E+13 Y-91 5.30E+13 Y-92 4.34E+12 Y-93 6.78E+12 Zr-95 6.89E+13 Zr-97 1.85E+13 Nb-95 7.08E+13 Mo-99 1.61E+16 Tc-99m 1.54E+16 Ru-103 1.77E+16 Ru-105 7.78E+13 Ru-106 6.31E+15 Rh-105 6.98E+15
Calculation IP-CALC-09-00265, Rev. 0, Att. A.1, Page 23 Sb-127 1.31E+15 Sb-129 2.71E+13 Te-127 1.40E+15 Te-127m 2.16E+14 Te-129 4.88E+14 Te-129m 7.06E+14 Te-131m 1.05E+15 Te-132 1.64E+16 I-131 3.42E+17 I-132 1.70E+16 I-133 2.67E+17 I-134 5.97E+06 I-135 2.43E+16 Xe-133 5.27E+18 Xe-135 2.23E+17 Cs-134 1.65E+16 Cs-136 4.50E+15 Cs-137 9.54E+15 Ba-139 4.23E+08 Ba-140 4.75E+15 La-140 2.15E+15 La-141 2.25E+11 La-142 3.03E+07 Ce-141 6.19E+14 Ce-143 3.01E+14 Ce-144 5.01E+14 Pr-143 8.67E+13 Nd-147 2.54E+13 Np-239 5.28E+15 Pu-238 1.73E+12 Pu-239 1.47E+11 Pu-240 2.20E+11 Pu-241 4.94E+13 Am-241 6.69E+09 Cm-242 1.59E+12 Cm-244 1.73E+11
- BEGINNING OF CHANGE CASE 5 USER INPUT ********
- RELEASE DATA BLOCK *************
- SOURCE TERM NUMBER 6 OF 8 262 RDATNAM2001 'LATE MEDIUM'
- RECORD NUMBER 262 REPLACES RECORD NUMBER 123 ********
263 RDOALARM001 8.94E+03
- RECORD NUMBER 263 REPLACES RECORD NUMBER 124 ********
264 RDNUMREL001 1
- RECORD NUMBER 264 REPLACES RECORD NUMBER 125 ********
265 RDMAXRIS001 1
- RECORD NUMBER 265 REPLACES RECORD NUMBER 126 ********
266 RDREFTIM001 0.5
- RECORD NUMBER 266 REPLACES RECORD NUMBER 127 ********
267 RDPLHEAT001 9.20E+05
- RECORD NUMBER 267 REPLACES RECORD NUMBER 128 ********
268 RDPLHITE001 30.
- RECORD NUMBER 268 REPLACES RECORD NUMBER 129 ********
269 RDPLUDUR001 8.64E+04
- RECORD NUMBER 269 REPLACES RECORD NUMBER 130 ********
Calculation IP-CALC-09-00265, Rev. 0, Att. A.1, Page 24 270 RDPDELAY001 8.04E+04
- RECORD NUMBER 270 REPLACES RECORD NUMBER 131 ********
- Xe/Kr I Cs Te Sr Ru La Ce Ba 271 RDRELFRC001 8.2E-01 1.5E-02 4.3E-03 1.5E-03 8.0E-05 1.4E-03 5.1E-06 4.7E-05 3.5E-04
- RECORD NUMBER 271 REPLACES RECORD NUMBER 206 ********
- TERMINATOR RECORD ENCOUNTERED -- END OF CHANGE CASE 5 USER INPUT ********
USER INPUT PROCESSING
SUMMARY
- CHANGE CASE 5 NUMBER OF RECORDS CHANGED = 10 NUMBER OF RECORDS ADDED = 0 RELEASED INVENTORY OF ALL PLUMES Co-58 4.20E+13 Co-60 3.25E+13 Kr-85 3.15E+16 Kr-85m 3.43E+15 Kr-87 9.97E+09 Kr-88 4.31E+14 Rb-86 3.39E+13 Sr-89 2.42E+14 Sr-90 2.44E+13 Sr-91 2.53E+13 Sr-92 5.15E+10 Y-90 8.69E+12 Y-91 2.08E+13 Y-92 1.17E+12 Y-93 2.34E+12 Zr-95 2.70E+13 Zr-97 6.75E+12 Nb-95 2.78E+13 Mo-99 5.96E+15 Tc-99m 5.73E+15 Ru-103 6.68E+15 Ru-105 2.21E+13 Ru-106 2.39E+15 Rh-105 2.55E+15 Sb-127 4.02E+14 Sb-129 6.32E+12 Te-127 4.33E+14 Te-127m 6.76E+13 Te-129 1.50E+14 Te-129m 2.20E+14 Te-131m 3.15E+14 Te-132 5.06E+15 I-131 4.25E+16 I-132 5.21E+15 I-133 3.13E+16 I-134 1.75E+05 I-135 2.50E+15 Xe-133 4.27E+18 Xe-135 1.09E+17 Cs-134 3.09E+15 Cs-136 8.37E+14
Calculation IP-CALC-09-00265, Rev. 0, Att. A.1, Page 25 Cs-137 1.78E+15 Ba-139 6.48E+07 Ba-140 1.82E+15 La-140 8.58E+14 La-141 6.39E+10 La-142 5.21E+06 Ce-141 2.42E+14 Ce-143 1.13E+14 Ce-144 1.96E+14 Pr-143 3.43E+13 Nd-147 9.92E+12 Np-239 2.02E+15 Pu-238 6.77E+11 Pu-239 5.76E+10 Pu-240 8.60E+10 Pu-241 1.94E+13 Am-241 2.63E+09 Cm-242 6.23E+11 Cm-244 6.78E+10
- BEGINNING OF CHANGE CASE 6 USER INPUT ********
- RELEASE DATA BLOCK *************
- SOURCE TERM NUMBER 7 OF 8 272 RDATNAM2001 'LATE LOW'
- RECORD NUMBER 272 REPLACES RECORD NUMBER 123 ********
273 RDOALARM001 2.19E+04
- RECORD NUMBER 273 REPLACES RECORD NUMBER 124 ********
274 RDNUMREL001 1
- RECORD NUMBER 274 REPLACES RECORD NUMBER 125 ********
275 RDMAXRIS001 1
- RECORD NUMBER 275 REPLACES RECORD NUMBER 126 ********
276 RDREFTIM001 0.5
- RECORD NUMBER 276 REPLACES RECORD NUMBER 127 ********
277 RDPLHEAT001 9.20E+05
- RECORD NUMBER 277 REPLACES RECORD NUMBER 128 ********
278 RDPLHITE001 30.
- RECORD NUMBER 278 REPLACES RECORD NUMBER 129 ********
279 RDPLUDUR001 8.64E+04
- RECORD NUMBER 279 REPLACES RECORD NUMBER 130 ********
280 RDPDELAY001 9.90E+04
- RECORD NUMBER 280 REPLACES RECORD NUMBER 131 ********
- Xe/Kr I Cs Te Sr Ru La Ce Ba 281 RDRELFRC001 7.0E-01 1.1E-03 7.9E-04 1.2E-03 8.7E-05 3.5E-06 2.6E-06 2.4E-05 7.4E-05
- RECORD NUMBER 281 REPLACES RECORD NUMBER 206 ********
- TERMINATOR RECORD ENCOUNTERED -- END OF CHANGE CASE 6 USER INPUT ********
USER INPUT PROCESSING
SUMMARY
- CHANGE CASE 6 NUMBER OF RECORDS CHANGED = 10 NUMBER OF RECORDS ADDED = 0
Calculation IP-CALC-09-00265, Rev. 0, Att. A.1, Page 26 RELEASED INVENTORY OF ALL PLUMES Co-58 1.05E+11 Co-60 8.12E+10 Kr-85 2.69E+16 Kr-85m 1.32E+15 Kr-87 5.09E+08 Kr-88 1.04E+14 Rb-86 6.18E+12 Sr-89 2.62E+14 Sr-90 2.65E+13 Sr-91 1.89E+13 Sr-92 1.49E+10 Y-90 9.77E+12 Y-91 1.10E+13 Y-92 4.77E+11 Y-93 8.38E+11 Zr-95 1.37E+13 Zr-97 2.78E+12 Nb-95 1.42E+13 Mo-99 1.41E+13 Tc-99m 1.36E+13 Ru-103 1.66E+13 Ru-105 2.47E+10 Ru-106 5.97E+12 Rh-105 5.76E+12 Sb-127 3.10E+14 Sb-129 2.21E+12 Te-127 3.35E+14 Te-127m 5.41E+13 Te-129 1.17E+14 Te-129m 1.75E+14 Te-131m 2.24E+14 Te-132 3.86E+15 I-131 3.09E+15 I-132 3.98E+15 I-133 1.93E+15 I-134 2.16E+02 I-135 1.07E+14 Xe-133 3.54E+18 Xe-135 5.80E+16 Cs-134 5.67E+14 Cs-136 1.52E+14 Cs-137 3.28E+14 Ba-139 1.02E+06 Ba-140 3.80E+14 La-140 2.03E+14 La-141 1.31E+10 La-142 2.60E+05 Ce-141 1.23E+14 Ce-143 5.19E+13 Ce-144 1.00E+14 Pr-143 1.79E+13 Nd-147 4.99E+12 Np-239 9.70E+14 Pu-238 3.46E+11 Pu-239 2.94E+10 Pu-240 4.39E+10 Pu-241 9.89E+12 Am-241 1.35E+09
Calculation IP-CALC-09-00265, Rev. 0, Att. A.1, Page 27 Cm-242 3.18E+11 Cm-244 3.46E+10
- BEGINNING OF CHANGE CASE 7 USER INPUT ********
- RELEASE DATA BLOCK *************
- SOURCE TERM NUMBER 8 OF 8 282 RDATNAM2001 'LATE LOWLOW'
- RECORD NUMBER 282 REPLACES RECORD NUMBER 123 ********
283 RDOALARM001 2.56E+04
- RECORD NUMBER 283 REPLACES RECORD NUMBER 124 ********
284 RDNUMREL001 1
- RECORD NUMBER 284 REPLACES RECORD NUMBER 125 ********
285 RDMAXRIS001 1
- RECORD NUMBER 285 REPLACES RECORD NUMBER 126 ********
286 RDREFTIM001 0.5
- RECORD NUMBER 286 REPLACES RECORD NUMBER 127 ********
287 RDPLHEAT001 9.20E+05
- RECORD NUMBER 287 REPLACES RECORD NUMBER 128 ********
288 RDPLHITE001 30.
- RECORD NUMBER 288 REPLACES RECORD NUMBER 129 ********
289 RDPLUDUR001 8.64E+04
- RECORD NUMBER 289 REPLACES RECORD NUMBER 130 ********
290 RDPDELAY001 1.13E+05
- RECORD NUMBER 290 REPLACES RECORD NUMBER 131 ********
- Xe/Kr I Cs Te Sr Ru La Ce Ba 291 RDRELFRC001 9.1E-01 8.1E-04 7.0E-04 7.6E-04 3.6E-05 2.1E-06 1.1E-06 1.2E-05 3.3E-05
- RECORD NUMBER 291 REPLACES RECORD NUMBER 206 ********
- TERMINATOR RECORD ENCOUNTERED -- END OF CHANGE CASE 7 USER INPUT ********
USER INPUT PROCESSING
SUMMARY
- CHANGE CASE 7 NUMBER OF RECORDS CHANGED = 10 NUMBER OF RECORDS ADDED = 0 RELEASED INVENTORY OF ALL PLUMES Co-58 6.27E+10 Co-60 4.87E+10 Kr-85 3.49E+16 Kr-85m 9.37E+14 Kr-87 7.95E+07 Kr-88 5.25E+13 Rb-86 5.44E+12 Sr-89 1.08E+14 Sr-90 1.10E+13 Sr-91 5.88E+12 Sr-92 2.28E+09 Y-90 4.34E+12 Y-91 4.66E+12 Y-92 9.41E+10 Y-93 2.72E+11 Zr-95 5.80E+12
Calculation IP-CALC-09-00265, Rev. 0, Att. A.1, Page 28 Zr-97 1.00E+12 Nb-95 5.99E+12 Mo-99 8.14E+12 Tc-99m 7.83E+12 Ru-103 9.95E+12 Ru-105 8.07E+09 Ru-106 3.58E+12 Rh-105 3.20E+12 Sb-127 1.90E+14 Sb-129 7.49E+11 Te-127 2.07E+14 Te-127m 3.43E+13 Te-129 7.29E+13 Te-129m 1.11E+14 Te-131m 1.29E+14 Te-132 2.36E+15 I-131 2.24E+15 I-132 2.44E+15 I-133 1.25E+15 I-134 7.35E+00 I-135 5.23E+13 Xe-133 4.50E+18 Xe-135 5.59E+16 Cs-134 5.02E+14 Cs-136 1.34E+14 Cs-137 2.90E+14 Ba-139 6.43E+04 Ba-140 1.68E+14 La-140 9.55E+13 La-141 2.79E+09 La-142 1.92E+04 Ce-141 6.13E+13 Ce-143 2.39E+13 Ce-144 5.01E+13 Pr-143 8.22E+12 Nd-147 2.09E+12 Np-239 4.62E+14 Pu-238 1.73E+11 Pu-239 1.47E+10 Pu-240 2.20E+10 Pu-241 4.94E+12 Am-241 5.80E+08 Cm-242 1.34E+11 Cm-244 1.46E+10 USER INPUT IS READ FROM UNIT 25 RECORD IDENTIFIER FIELDS 11 CHARACTERS LONG ARE EXPECTED.
THE FIRST 100 COLUMNS OF EACH INPUT RECORD ARE PROCESSED.
THE MAXIMUM NUMBER OF IDENTIFIER RECORDS THAT MAY BE SAVED AS THE BASE CASE IS 1000.
RECORD NUMBER RECORD
- GENERAL DESCRIPTIVE TITLE DESCRIBING THIS "EARLY" INPUT FILE 1 MIEANAM1001 'EARLY.IN, IPEC INPUT FROM THE EVACUATION TIME ESTIMATES' 2 DCF_FILE001 'DOSDATA.INP' (DCF file of MACCS 1.5.11.1)
Calculation IP-CALC-09-00265, Rev. 0, Att. A.1, Page 29
- ORGNAM ORGFLG 3 MIORGDEF001 'A-SKIN' .TRUE.
4 MIORGDEF002 'A-RED MARR' .TRUE.
5 MIORGDEF003 'A-LUNGS' .TRUE.
6 MIORGDEF004 'A-THYROIDH' .TRUE.
7 MIORGDEF005 'A-STOMACH' .TRUE.
8 MIORGDEF006 'A-LOWER LI' .FALSE. (does not contribute to early fatalities) 9 MIORGDEF007 'L-EDEWBODY' .TRUE.
10 MIORGDEF008 'L-RED MARR' .TRUE.
11 MIORGDEF009 'L-BONE SUR' .TRUE.
12 MIORGDEF010 'L-BREAST' .TRUE.
13 MIORGDEF011 'L-LUNGS' .TRUE.
14 MIORGDEF012 'L-THYROID' .TRUE.
15 MIORGDEF013 'L-LOWER LI' .TRUE.
16 MIORGDEF014 'L-BLAD WAL' .TRUE.
17 MIORGDEF015 'L-LIVER' .FALSE.
18 MIORGDEF016 'L-THYROIDH' .TRUE.
- FLAG TO INDICATE THAT THIS IS THE LAST PROGRAM IN THE SERIES TO BE RUN 19 MIENDAT2001 .FALSE. (SET THIS VALUE TO .TRUE. TO SKIP CHRONC)
- DISPERSION MODEL OPTION CODE: 1
- STRAIGHT LINE
- 2
- WIND-SHIFT WITH ROTATION
- 3
- WIND-SHIFT WITHOUT ROTATION 20 MIIPLUME001 2
- NUMBER OF FINE GRID SUBDIVISIONS USED BY THE MODEL 21 MINUMFIN001 7 (3, 5 OR 7 ALLOWED)
- LEVEL OF DEBUG OUTPUT REQUIRED, NORMAL RUNS SHOULD SPECIFY ZERO 22 MIIPRINT001 0
- LOGICAL FLAG SIGNIFYING THAT THE BREAKDOWN OF RISK BY WEATHER CATEGORY
- BIN ARE TO BE PRESENTED TO SHOW THEIR RELATIVE CONTRIBUTION TO THE MEAN
- RISBIN 23 MIRISCAT001 .FALSE.
- FLAG INDICATING IF WIND-ROSES FROM ATMOS ARE TO BE OVERRIDDEN 24 MIOVRRID001 .FALSE. (USE THE WIND ROSE CALCULATED FOR EACH WEATHER BIN)
- POPULATION DISTRIBUTION DATA BLOCK, LOADED BY INPOPU, STORED IN /POPDAT/
25 PDPOPFLG001 FILE
- PDPOPFLG001 UNIFORM
- PDIBEGIN001 1 (SPATIAL INTERVAL AT WHICH POPULATION BEGINS)
- PDPOPDEN001 50. (POPULATION DENSITY (PEOPLE PER SQUARE KILOMETER))
- SHIELDING AND EXPOSURE FACTORS, LOADED BY INDFAC, STORED IN /EADFAC/
- THREE VALUES OF EACH PROTECTION FACTOR ARE SUPPLIED,
Calculation IP-CALC-09-00265, Rev. 0, Att. A.1, Page 30
- ONE FOR EACH TYPE OF ACTIVTY:
- ACTIVITY TYPE:
- 1 - EVACUEES WHILE MOVING
- 2 - NORMAL ACTIVITY IN SHELTERING AND EVACUATION ZONE
- 3 - SHELTERED ACTIVITY
- CLOUD SHIELDING FACTOR
- SITE GG PB SEQ SUR ZION
- SHELTERING 0.7 0.5 0.65 0.6 0.5
- EVACUEES NORMAL SHELTER 26 SECSFACT001 1. 0.75 0.6
- SURRY SHELTERING VALUE
- PROTECTION FACTOR FOR INHALATION 27 SEPROTIN001 1. 0.41 0.33
- VALUES FOR NORMAL ACTIVITY AND
- SHELTERING SELECTED BY NRC STAFF
- BREATHING RATE (CUBIC METERS PER SECOND) 28 SEBRRATE001 2.66E-4 2.66E-4 2.66E-4
- SKIN PROTECTION FACTOR 29 SESKPFAC001 1.0 0.41 0.33
- VALUES FOR NORMAL ACTIVITY AND
- SHELTERING SELECTED BY NRC STAFF
- GROUND SHIELDING FACTOR
- SITE GG PB SEQ SUR ZION
- SHELTERING 0.25 0.1 0.2 0.2 0.1 30 SEGSHFAC001 0.5 0.4 0.2
- VALUE FOR NORMAL ACTIVITY SELECTED BY
- NRC STAFF
- RESUSPENSION INHALATION MODEL CONCENTRATION COEFFICIENT (/METER)
- RESCON = 1.E-4 IS APPROPRIATE FOR MECHANICAL RESUSPENSION BY VEHICLES.
- RESHAF = 2.11 DAYS CAUSES 1.E-4 TO DECAY IN ONE WEEK TO 1.E-5, THE VALUE
- OF RESCON USED IN THE FIRST TERM OF THE LONG-TERM RESUSPENSION EQUATION
- USED IN CHRONC.
31 SERESCON001 1.E-4 (RESUSPENSION IS TURNED ON)
- RESUSPENSION CONCENTRATION COEFFICIENT HALF-LIFE (SEC) 32 SERESHAF001 1.82E5 (2.11 DAYS)
- EVACUATION ZONE DATA BLOCK, LOADED BY EVNETW, STORED IN /NETWOR/, /EOPTIO/
- SPECIFIC DESCRIPTION OF THE EMERGENCY RESPONSE SCENARIO BEING USED 33 EZEANAM2001 'NO EVACUATION, RELOCATION MODELS APPLY EVERYWHE'
- THE TYPE OF WEIGHTING TO BE APPLIED TO THE EMERGENCY RESPONSE SCENARIOS
- YOU MUST SUPPLY A VALUE OF 'TIME' OR 'PEOPLE'
Calculation IP-CALC-09-00265, Rev. 0, Att. A.1, Page 31 34 EZWTNAME001 'PEOPLE'
- WEIGHTING FRACTION APPLICABLE TO THIS SCENARIO 35 EZWTFRAC001 1.00
- LAST RING IN THE MOVEMENT ZONE 36 EZLASMOV001 0 (A ZERO TURNS OFF THE EVACUATION MODEL)
- SHELTER AND RELOCATION ZONE DATA BLOCK, LOADED BY INPEMR,
- STORED IN /INPSRZ/, /RELOCA/
- DURATION OF THE EMERGENCY PHASE (SECONDS FROM PLUME ARRIVAL) 37 SRENDEMP001 604800. (ONE WEEK)
- CRITICAL ORGAN FOR RELOCATION DECISIONS 38 SRCRIORG001 'L-EDEWBODY'
- HOT SPOT RELOCATION TIME (SECONDS FROM PLUME ARRIVAL) 39 SRTIMHOT001 43200. (ONE-HALF DAY)
- NORMAL RELOCATION TIME (SECONDS FROM PLUME ARRIVAL) 40 SRTIMNRM001 86400. (ONE DAY)
- HOT SPOT RELOCATION DOSE CRITERION THRESHOLD (SIEVERTS) 41 SRDOSHOT001 0.5 (50 REM DOSE TO WHOLE BODY IN 1 WEEK TRIGGERS RELOCATION)
- NORMAL RELOCATION DOSE CRITERION THRESHOLD (SIEVERTS) 42 SRDOSNRM001 0.25 (25 REM DOSE TO WHOLE BODY IN 1 WEEK TRIGGERS RELOCATION)
- EARLY FATALITY MODEL PARAMETERS, LOADED BY INEFAT, STORED IN /EFATAL/
- NUMBER OF EARLY FATALITY EFFECTS 43 EFNUMEFA001 2
- ORGNAM EFFACA EFFACB EFFTHR 44 EFATAGRP001 'A-RED MARR' 3.8 5.0 1.5 45 EFATAGRP002 'A-LUNGS' 10.0 7.0 5.0
- EARLY INJURY MODEL PARAMETERS, LOADED BY INEINJ, STORED IN /EINJUR/
- NUMBER OF EARLY INJURY EFFECTS 46 EINUMEIN001 7
- EINAME ORGNAM EISUSC EITHRE EIFACA EIFACB 47 EINJUGRP001 'PRODROMAL VOMIT' 'A-STOMACH' 1. .5 2. 3.
Calculation IP-CALC-09-00265, Rev. 0, Att. A.1, Page 32 48 EINJUGRP002 'DIARRHEA' 'A-STOMACH' 1. 1. 3. 2.5 49 EINJUGRP003 'PNEUMONITIS' 'A-LUNGS' 1. 5. 10. 7.
50 EINJUGRP004 'SKIN ERYTHEMA' 'A-SKIN' 1. 3. 6. 5.
51 EINJUGRP005 'TRANSEPIDERMAL' 'A-SKIN' 1. 10. 20. 5.
52 EINJUGRP006 'THYROIDITIS' 'A-THYROIDH' 1. 40. 240. 2.
53 EINJUGRP007 'HYPOTHYROIDISM' 'A-THYROIDH' 1. 2. 60. 1.3
- ACUTE EXPOSURE CANCER PARAMETERS, LOADED BY INACAN STORED IN /ACANCR/.
- NUMBER OF ACUTE EXPOSURE CANCER EFFECTS 54 LCNUMACA001 7
- THRESHOLD DOSE FOR APPLYING THE DOSE DEPENDENT REDUCTION FACTOR 55 LCDDTHRE001 0.2 (LOWEST DOSE FOR WHICH DDREFA WILL BE APPLIED)
- DOSE THRESHOLD FOR LINEAR DOSE RESPONSE (Sv) 56 LCACTHRE001 0.0 (LINEAR-QUADRATIC MODEL IS NOT BEING USED)
- ACNAME ORGNAM ACSUSC DOSEFA DOSEFB CFRISK CIRISK DDREFA 57 LCANCERS001 'LEUKEMIA' 'L-RED MARR' 1.0 1.0 0.0 9.70E-3 0.0 2.0 58 LCANCERS002 'BONE' 'L-BONE SUR' 1.0 1.0 0.0 9.00E-4 0.0 2.0 59 LCANCERS003 'BREAST' 'L-BREAST' 1.0 1.0 0.0 5.40E-3 1.7E-2 1.0 60 LCANCERS004 'LUNG' 'L-LUNGS' 1.0 1.0 0.0 1.55E-2 0.0 2.0 61 LCANCERS005 'THYROID' 'L-THYROIDH' 1.0 1.0 0.0 7.20E-4 7.2E-3 1.0 62 LCANCERS006 'GI' 'L-LOWER LI' 1.0 1.0 0.0 3.36E-2 0.0 2.0 63 LCANCERS007 'OTHER' 'L-EDEWBODY' 1.0 1.0 0.0 2.76E-2 0.0 2.0
- RESULT 1 OPTIONS BLOCK, LOADED BY INOUT1, STORED IN /INOUT1/
- TOTAL NUMBER OF A GIVEN EFFECT (LATENT CANCER, EARLY DEATH, EARLY INJURY)
- NUMBER OF DESIRED RESULTS OF THIS TYPE 64 TYPE1NUMBER 4 65 TYPE1OUT001 'ERL FAT/TOTAL' 1 15 NOCCDF (0 TO 50 MILES) 66 TYPE1OUT009 'CAN FAT/TOTAL' 1 15 NOCCDF 67 TYPE1OUT019 'CAN FAT/TOTAL' 1 11 NOCCDF (0 TO 10 MILES) 68 TYPE1OUT020 'ERL FAT/TOTAL' 1 11 (0 TO 10 MILES)
- RESULT 2 OPTIONS BLOCK, LOADED BY INOUT2, STORED IN /INOUT2/
- FURTHEST DISTANCE AT WHICH A GIVEN RISK OF EARLY DEATH IS EXCEEDED.
- NUMBER OF DESIRED RESULTS OF THIS TYPE 69 TYPE2NUMBER 0
- FATALITY RISK THRESHOLD
- TYPE2OUT001 0.
- RESULT 3 OPTIONS BLOCK, LOADED BY INOUT3, STORED IN /INOUT3/
- NUMBER OF PEOPLE WHOSE DOSE TO A GIVEN ORGAN EXCEEDS A GIVEN THRESHOLD.
- NUMBER OF DESIRED RESULTS OF THIS TYPE
Calculation IP-CALC-09-00265, Rev. 0, Att. A.1, Page 33 70 TYPE3NUMBER 0
- ORGAN NAME DOSE THRESHOLD (Sv)
- TYPE3OUT001 'A-RED MARR' 1.5
- TYPE3OUT002 'A-LUNGS' 5.0
- TYPE3OUT003 'L-EDEWBODY' 0.05
- RESULT 4 OPTIONS BLOCK, LOADED BY INOUT4, STORED IN /INOUT4/
- 360 DEGREE AVERAGE RISK OF A GIVEN EFFECT AT A GIVEN DISTANCE.
- POSSIBLE TYPES OF EFFECTS ARE:
- 'ERL FAT/TOTAL'
- 'ERL INJ/INJURY NAME'
- 'CAN FAT/CANCER NAME'
- 'CAN FAT/TOTAL'
- NUMBER OF DESIRED RESULTS OF THIS TYPE 71 TYPE4NUMBER 3
- RADIAL INDEX TYPE OF EFFECT 72 TYPE4OUT001 1 'ERL FAT/TOTAL' 73 TYPE4OUT002 2 'ERL FAT/TOTAL' 74 TYPE4OUT003 3 'ERL FAT/TOTAL'
- RESULT 5 OPTIONS BLOCK, LOADED BY INOUT5, STORED IN /INOUT5/
- TOTAL POPULATION DOSE TO A GIVEN ORGAN BETWEEN TWO DISTANCES.
- NUMBER OF DESIRED RESULTS OF THIS TYPE 75 TYPE5NUMBER 1
- ORGAN I1DIS5 I2DIS5 76 TYPE5OUT001 'L-EDEWBODY' 1 15 NOCCDF (0-50 MILES)
- RESULT 6 OPTIONS BLOCK, LOADED BY INOUT6, STORED IN /INOUT6/
- CENTERLINE DOSE TO AN ORGAN VS DIST BY PATHWAY, PATHWAY NAMES ARE AS FOLLOWS:
- PATHWAY NAME:
- 'CLD' - CLOUDSHINE
- 'GRD' - GROUNDSHINE
- 'INH ACU' - "ACUTE DOSE EQUIVALENT" FROM DIRECT INHALATION OF THE CLOUD
- 'INH LIF' - "LIFETIME DOSE COMMITMENT" FROM DIRECT INHALATION OF THE CLOUD
- 'RES ACU' - "ACUTE DOSE EQUIVALENT" FROM RESUSPENSION INHALATION
- 'RES LIF' - "LIFETIME DOSE COMMITMENT" FROM RESUSPENSION INHALATION
- 'TOT ACU' - "ACUTE DOSE EQUIVALENT" FROM ALL PATHWAYS
- 'TOT LIF' - "LIFETIME DOSE COMMITMENT" FROM ALL PATHWAYS
- NUMBER OF DESIRED RESULTS OF THIS TYPE 77 TYPE6NUMBER 0
- ORGNAM PATHNM I1DIS6 I2DIS6
Calculation IP-CALC-09-00265, Rev. 0, Att. A.1, Page 34
- TYPE6OUT001 'A-RED MARR' 'TOT ACU' 1 19 (0-50 MILES)
- TYPE6OUT002 'A-LUNGS' 'TOT ACU' 1 19 (0-50 MILES)
- TYPE6OUT003 'L-EDEWBODY' 'TOT LIF' 1 26 (0-1000 MILES)
- RESULT 7 OPTIONS BLOCK, LOADED BY INOUT7, STORED IN /INOUT7/
- CENTERLINE RISK OF A GIVEN EFFECT VS DISTANCE
- NUMBER OF DESIRED RESULTS OF THIS TYPE 78 TYPE7NUMBER 0
- NAME I1DIS7 I2DIS7
- TYPE7OUT001 'ERL FAT/TOTAL' 1 19 (0-50 MILES)
- TYPE7OUT002 'CAN FAT/TOTAL' 1 26 (0-1000 MILES)
- RESULT 8 OPTIONS BLOCK, LOADED BY INOUT8, STORED IN /INOUT8/
- POPULATION WEIGHTED FATALITY RISK BETWEEN 2 DISTANCES
- NUMBER OF DESIRED RESULTS OF THIS TYPE 79 TYPE8NUMBER 2
- NAME I1DIS8 I2DIS8 80 TYPE8OUT001 'ERL FAT/TOTAL' 1 3 NOCCDF 81 TYPE8OUT002 'CAN FAT/TOTAL' 1 11 NOCCDF (0-10 MILES)
- RESULT A OPTIONS BLOCK, LOADED BY INOUTA, STORED IN /INOUTA/
- peak dose to a given organ
- NUMA 82 TYPEANUMBER 0
- ORGNAM I1DISA I2DISA
- TYPEAOUT001 'L-EDEWBODY' 1 15
- TERMINATOR RECORD ENCOUNTERED -- END OF BASE CASE USER INPUT ********
USER INPUT PROCESSING
SUMMARY
- BASE CASE NUMBER OF RECORDS READ = 341 NUMBER OF BLANK OR COMMENT RECORDS READ = 258 NUMBER OF TERMINATOR RECORDS = 1 NUMBER OF RECORDS PROCESSED = 82 NUMBER OF PROCESSED RECORDS DUPLICATED = 0 NUMBER OF PROCESSED RECORDS SORTED = 82 The list of defined organs is as follows (A- is ACUTE and L- is LIFETIME):
A-SKIN A-RED MARR
Calculation IP-CALC-09-00265, Rev. 0, Att. A.1, Page 35 A-LUNGS A-THYROIDH A-STOMACH L-EDEWBODY L-RED MARR L-BONE SUR L-BREAST L-LUNGS L-THYROID L-LOWER LI L-BLAD WAL L-THYROIDH Am using a DOSFAC/DOSFAC2/IDCF2 dose factor file READING FROM A DOSE CONVERSION FILE WITH THE FOLLOWING HEADER:
MACCS File DOSDATA.INP: Changed by D. CHANIN25-JUN-92, 09:53:47 Seven new organs added with MACCS Version 1.5.11.1 NO EVACUATION REQUESTED USING THE FOLLOWING SITE DATA FILE:
MACCS2 Site Data File for Indian Point Energy Center SITE FILE 15 SPATIAL INTERVALS 16 WIND DIRECTIONS 7 CROP CATEGORIES 4 WATER PATHWAY ISOTOPES 1 WATERSHEDS 21 ECONOMIC REGIONS SPATIAL DISTANCES KILOMETERS 0.3219 1.6093 3.2187 4.8280 6.4374 8.0467 9.6561 11.2654 12.8748 14.4841 16.0935 32.1869 48.2804 64.3739 80.4674 POPULATION
- 6. 0. 271. 2059. 2501. 909. 931. 1223.
1389. 1503. 1696. 22955. 30654. 39620. 51057.0
- 16. 7. 170. 1943. 2912. 2051. 1177. 1388.
1577. 1798. 1913. 28140. 39917. 56226. 67213.0
- 17. 193. 883. 2131. 2964. 3843. 3910. 3059.
2464. 1998. 1915. 29419. 53692. 62559. 41261.0
- 17. 364. 1275. 2132. 2977. 3453. 4507. 5282.
6140. 6960. 7279. 74856. 119073. 152175. 176338.0
- 17. 390. 1218. 2138. 2934. 3792. 4424. 5513.
5587. 7201. 8076. 118335. 156720. 200581. 208394.0
- 17. 409. 1256. 2136. 2970. 3592. 3698. 3857.
5734. 6783. 7409. 121515. 144267. 54180. 34361.0
- 17. 410. 1274. 2138. 2872. 3808. 4537. 5279.
6284. 7194. 8060. 111946. 87735. 236426. 379990.0
- 17. 360. 1268. 1645. 882. 495. 15. 1442.
948. 1911. 3214. 98326. 481703. 1380249. 1218170.0
- 17. 400. 701. 246. 124. 620. 1538. 3253.
4129. 4455. 5138. 135211. 1164596. 3732339. 3164306.0
- 17. 377. 562. 500. 1700. 2882. 3544. 4187.
4873. 5517. 6159. 202605. 395389. 922649. 1034467.0
- 17. 217. 187. 1566. 2274. 2916. 3574. 4188.
4361. 5358. 6138. 183372. 276902. 197362. 246076.0
- 9. 0. 620. 1623. 2197. 2924. 3550. 4014.
4196. 4255. 4335. 64428. 209197. 109102. 85849.0
Calculation IP-CALC-09-00265, Rev. 0, Att. A.1, Page 36
- 3. 0. 855. 1602. 2267. 2815. 2368. 1787.
1423. 1775. 2030. 32026. 50974. 61380. 57384.0
- 2. 0. 938. 1624. 2245. 1341. 1135. 1419.
1505. 1756. 2071. 32528. 54577. 57977. 29719.0
- 2. 45. 974. 1589. 1933. 972. 1140. 1351.
1541. 1781. 2093. 32572. 54557. 24046. 22317.0
- 3. 50. 809. 1051. 1587. 740. 1204. 1407.
1620. 1787. 2028. 31660. 32569. 27599. 34374.0 LAND FRACTION 0.37 0.00 0.23 0.96 0.99 0.94 0.78 0.87 0.85 0.81 0.82 0.83 0.94 0.94 0.93 0.92 0.02 0.13 0.91 0.97 0.98 1.00 1.00 0.98 0.99 0.94 0.95 0.99 0.99 0.98 1.00 0.47 0.69 1.00 0.99 1.00 0.98 0.96 0.95 1.00 0.94 0.91 0.94 0.95 0.96 1.00 0.89 0.99 1.00 0.99 0.90 0.96 0.95 0.96 0.96 0.97 0.91 0.92 0.95 0.98 1.00 0.95 0.95 1.00 0.98 0.99 0.94 0.99 0.87 0.99 0.99 0.92 0.97 0.97 0.78 1.00 1.00 0.98 1.00 0.99 0.93 0.79 0.69 0.89 0.93 0.91 0.97 0.95 0.27 0.12 1.00 1.00 0.99 1.00 0.96 0.99 0.96 0.95 0.98 0.99 0.99 0.93 0.53 0.48 0.98 1.00 0.88 0.99 0.77 0.29 0.13 0.00 0.26 0.16 0.30 0.43 0.77 0.70 0.79 0.82 1.00 0.97 0.55 0.12 0.05 0.21 0.43 0.77 0.85 0.81 0.83 0.84 0.87 0.81 0.59 1.00 0.92 0.44 0.31 0.75 0.99 0.99 0.99 1.00 1.00 1.00 0.99 0.99 0.93 0.92 1.00 0.53 0.18 0.96 1.00 1.00 1.00 0.99 0.89 0.97 0.99 0.98 0.93 0.90 0.94 0.52 0.00 0.64 1.00 0.97 1.00 0.99 0.95 0.91 0.92 0.94 0.94 0.93 0.97 0.94 0.19 0.00 0.88 0.99 1.00 1.00 1.00 0.98 0.86 0.95 0.97 0.97 0.98 0.97 0.97 0.13 0.00 0.96 1.00 1.00 0.99 0.94 0.99 0.91 0.94 0.99 0.98 0.99 0.97 0.95 0.14 0.14 1.00 0.98 0.99 0.98 0.94 0.94 0.93 0.95 1.00 0.98 0.99 0.99 0.96 0.20 0.16 0.83 0.57 0.65 0.75 0.99 0.98 0.98 0.95 0.97 0.96 0.96 0.99 0.96 REGION INDEX 202120202014141414131406060606 202120202014141414141414060606 202020202020201414141414060303 202020202020202020202020010104 202020202020202020202020010104 202020202020202020202020010117 202020202020202020202020011217 202020202020212020202020201212 202020202116161616161616021511 202020161616161616161602020510 202016161616161616161616080707 202116161616161616161613080909 202116161616131313131313130909 202116161613131313131313131318 201616161613131313131313131818 201616162013131313131313191919 WATERSHED INDEX 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
Calculation IP-CALC-09-00265, Rev. 0, Att. A.1, Page 37 CROP SEASON AND SHARE 1 PASTURE 90. 270. 0.0162 2 STORED FORAGE 150. 240. 0.0480 3 GRAINS 150. 240. 0.0079 4 GRN LEAFY VEGETABLES 150. 240. 0.0005 5 OTHER FOOD CROPS 150. 240. 0.0036 6 LEGUMES AND SEEDS 150. 240. 0.0002 7 ROOTS AND TUBERS 150. 240. 0.0018 WATERSHED DEFINITION -- INITIAL AND ANNUAL WASHOFF AND INGESTION FACTORS 1 Sr-89 5.00E-06 2 Sr-90 5.00E-06 3 Cs-134 5.00E-06 4 Cs-137 5.00E-06 REGIONAL ECONOMIC DATA 01 FAIRFIELD 0.032 .008 5831.0 66592.0 287881.0 02 BERGEN 0.009 .000 14568.0 124496.0 262186.0 03 LITCHFIELD 0.159 .371 795.0 22373.0 186016.0 04 NEWHAVEN 0.067 .029 5439.0 36942.0 192427.0 05 ESSEX 0.002 .000 11903.0 120139.0 197400.0 06 DUTCHESS 0.219 .207 698.0 16206.0 169417.0 07 MORRIS 0.057 .006 6005.0 67365.0 277661.0 08 PASSAIC 0.013 .000 9836.0 81944.0 161864.0 09 SUSSEX 0.226 .311 483.0 18496.0 165741.0 10 UNION 0.003 .000 91646.0 243939.0 209708.0 11 KINGS 0.000 .000 0.0 0.0 123701.0 12 NASSAU 0.006 .000 18237.0 88422.0 239932.0 13 ORANGE 0.207 .288 1516.0 13148.0 148873.0 14 PUTNAM 0.045 .000 892.0 24525.0 180274.0 15 QUEENS 0.000 .000 0.0 0.0 226728.0 16 ROCKLAND 0.011 .047 6365.0 65755.0 203359.0 17 SUFFOLK 0.058 .000 14567.0 54566.0 192471.0 18 SULLIVAN 0.103 .233 1466.0 7911.0 139374.0 19 ULSTER 0.116 .043 1019.0 9908.0 138739.0 20 WESTCHESTR 0.036 .009 2206.0 39116.0 263389.0 21 WATER 0.000 .000 0.0 0.0 0.0 POPULATION
>>The Record Identifier TYPEBNUMBER was not found:
>>Type B results not being generated USER INPUT IS READ FROM UNIT 26 RECORD IDENTIFIER FIELDS 11 CHARACTERS LONG ARE EXPECTED.
THE FIRST 100 COLUMNS OF EACH INPUT RECORD ARE PROCESSED.
THE MAXIMUM NUMBER OF IDENTIFIER RECORDS THAT MAY BE SAVED AS THE BASE CASE IS 1000.
RECORD NUMBER RECORD
- GENERAL DESCRIPTIVE TITLE DESCRIBING THIS "CHRONC" INPUT FILE 1 CHCHNAME001 'CHRONC.IN - IPEC, "New" COMIDA2-Based Food Model'
- EMERGENCY RESPONSE COST DATA BLOCK
- DAILY COST FOR A PERSON WHO IS EVACUATED (DOLLARS/PERSON-DAY) 2 CHEVACST001 46.7 (INCLUDES FOOD AND HOUSING COSTS BUT NOT LOST INCOME)
Calculation IP-CALC-09-00265, Rev. 0, Att. A.1, Page 38
- DAILY COST FOR A PERSON WHO IS RELOCATED (DOLLARS/PERSON-DAY) 3 CHRELCST001 46.7 (INCLUDES FOOD AND HOUSING COSTS BUT NOT LOST INCOME)
- LONG TERM PROTECTIVE ACTION DATA BLOCK
- Duration of the intermediate phase period--at version 1.11c TMIPND is no
- longer processed. The new input variable DUR_INTPHAS is the period's
- duration, not the time after plume arrival at which the period ends.
4 DUR_INTPHAS 0.0 (in seconds) (no intermediate phase)
- LONG-TERM PHASE DOSE PROJECTION PERIOD, THE DURATION OF THE EXPOSURE
- PERIOD OVER WHICH THE LONG-TERM DOSE CRITERION IS EVALUATED (SECONDS) 5 CHTMPACT001 1.58E8 (5 YEARS)
- DOSE CRITERION FOR INTERMEDIATE PHASE RELOCATION (Sv) 6 CHDSCRTI001 1.0E5 (NO INTERMEDIATE PHASE RELOCATION)
- DOSE CRITERION FOR LONG-TERM PHASE RELOCATION (Sv) 7 CHDSCRLT001 0.04
- CRITICAL ORGAN NAME FOR LONG-TERM ACTIONS 8 CHCRTOCR001 'L-EDEWBODY'
- Long Term Exposure Period Previously permanently set to:
- one million years = 3.15 E13 seconds
- MACCS2 allowable range is 3.15E7 to 1.E10 9 CHEXPTIM001 9.45E8
- DECONTAMINATION PLAN DATA BLOCK
- NUMBER OF LEVELS OF DECONTAMINATION 10 CHLVLDEC001 2
- DECONTAMINATION TIMES CORRESPONDING TO THE LVLDEC LEVELS OF DECONTAMINATION
- (SECONDS) 11 CHTIMDEC001 5.184E6 1.0368E7 (60, 120 DAYS)
- DOSE REDUCTION FACTORS CORRESPONDING TO THE LVLDEC LEVELS OF DECONTAMINATION 12 CHDSRFCT001 3. 15.
- COST OF FARM DECONTAMINATION PER FARMLAND UNIT AREA (DOLLARS/HECTARE)
- FOR THE VARIOUS LEVELS OF DECONTAMINATION 13 CHCDFRM0001 972. 2160.
- COST OF NONFARM DECONTAMINATION PER RESIDENT PERSON (DOLLARS/PERSON)
- FOR THE VARIOUS LEVELS OF DECONTAMINATION
Calculation IP-CALC-09-00265, Rev. 0, Att. A.1, Page 39 14 CHCDNFRM001 5184. 13824.
- FRACTION OF FARMLAND DECONTAMINATION COST DUE TO LABOR
- FOR THE VARIOUS DECONTAMINATION LEVELS 15 CHFRFDL0001 .3 .35
- FRACTION OF NON-FARM DECONTAMINATION COST DUE TO LABOR
- FOR THE VARIOUS DECONTAMINATION LEVELS 16 CHFRNFDL001 .7 .5
- FRACTION OF TIME WORKERS IN FARM AREAS SPEND IN CONTAMINATED AREAS
- FOR THE VARIOUS DECONTAMINATION LEVELS 17 CHTFWKF0001 .10 .33
- FRACTION OF TIME WORKERS IN NON-FARM AREAS SPEND IN CONTAMINATED AREAS
- FOR THE VARIOUS DECONTAMINATION LEVELS 18 CHTFWKNF001 .33 .33
- AVERAGE COST OF DECONTAMINATION LABOR (DOLLARS/MAN-YEAR) 19 CHDLBCST001 60480.
- INTERDICTION COST DATA BLOCK
- DEPRECIATION (DETERIORATION) RATE DURING INTERDICTION PERIOD (PER YEAR) 20 CHDPRATE001 .20 (VALUE OBTAINED FROM WASH-1400, APPENDIX 6)
- INVESTMENT INCOME RETURN (DISCOUNT RATE) DURING INTERDICTION PERIOD (PER YEAR)
- THIS VALUE SHOULD BE DERIVED AS A REAL RETURN RATE ADJUSTED FOR INFLATION 21 CHDSRATE001 .12 (VALUE OBTAINED FROM WASH-1400, APPENDIX 6)
- POPULATION RELOCATION COST (DOLLARS/PERSON):
- ALTERNATIVE HOUSING, MOVING COSTS, AND LOST INCOME FOR PEOPLE IN
- AREAS WHICH REQUIRE DECONTAMINATION, INTERDICTION, OR CONDEMNATION 22 CHPOPCST001 8640.
- GROUNDSHINE WEATHERING DEFINITION DATA BLOCK
- NUMBER OF TERMS IN THE GROUNDSHINE WEATHERING RELATIONSHIP (EITHER 1 OR 2) 23 CHNGWTRM001 2
- GROUNDSHINE WEATHERING COEFFICIENTS 24 CHGWCOEF001 0.5 0.5 (JON HELTON)
- HALF LIVES CORRESPONDING TO THE GROUNDSHINE WEATHERING COEFFICIENTS (S) 25 CHTGWHLF001 1.6E7 2.8E9 (JON HELTON)
- RESUSPENSION WEATHERING DEFINITION DATA BLOCK
Calculation IP-CALC-09-00265, Rev. 0, Att. A.1, Page 40
- NUMBER OF TERMS IN THE RESUSPENSION WEATHERING RELATIONSHIP 26 CHNRWTRM001 3
- RESUSPENSION CONCENTRATION COEFFICIENTS (/ METER)
- RELATIONSHIP BETWEEN GROUND CONCENTRATION AND INSTANTANEOUS AIR CONC.
27 CHRWCOEF001 1.0E-5 1.0E-7 1.0E-9 (VALUES HERE SELECTED BY JON HELTON)
- HALF-LIVES CORRESPONDING TO THE RESUSPENSION CONCENTRATION COEFFICIENTS (S) 28 CHTRWHLF001 1.6E7 1.6E8 1.6E9 (6 MONTHS, 5 YEARS, 50 YEARS)
- SITE REGION DESCRIPTION DATA BLOCK
- FRACTION OF AREA THAT IS LAND IN THE REGION 29 CHFRACLD001 0.95 (ROUGH GUESS VALUE, SITE FILE OVERRIDES THIS VALUE)
- FRACTION OF LAND DEVOTED TO FARMING IN THE REGION 30 CHFRCFRM001 0.382 (VIRGINIA STATE VALUE, SITE FILE OVERRIDES THIS VALUE)
- AVERAGE VALUE OF ANNUAL FARM PRODUCTION IN THE REGION (DOLLARS/HECTARE)
- (CASH RECEIPTS FROM FARMING PLUS VALUE OF HOME CONSUMPTION)/(LAND IN FARMS) 31 CHFRMPRD001 371.0 (VIRGINIA STATE VALUE, SITE FILE OVERRIDES THIS VALUE)
- FRACTION OF FARM PRODUCTION RESULTING FROM DAIRY PRODUCTION IN THE REGION
- (VALUE OF MILK PRODUCED)/(CASH RECEIPTS FROM FARMING PLUS HOME CONSUMPTION) 32 CHDPFRCT001 0.198 (VIRGINIA STATE VALUE, SITE FILE OVERRIDES THIS VALUE)
- VALUE OF FARM WEALTH (DOLLARS/HECTARE)
- (AVERAGE VALUE PER HECTARE OF FARM LAND AND BUILDINGS TO 100 MILES) 33 CHVALWF0001 50071.
- FRACTION OF FARM WEALTH IN IMPROVEMENTS FOR THE REGION 34 CHFRFIM0001 0.25
- NON-FARM WEALTH, PROPERTY AND IMPROVEMENTS FOR THE REGION (DOLLARS/PERSON)
- THE VALUE OF ALL RESIDENTIAL, BUSINESS, AND PUBLIC ASSETS WHICH WOULD BE
- LOST IN THE EVENT OF PERMANENT INTERDICTION (CONDEMNATION) OF THE AREA 35 CHVALWNF001 208838.
- FRACTION OF NON-FARM WEALTH IN IMPROVEMENTS FOR THE REGION 36 CHFRNFIM001 0.8 37 CHFDPATH001 'NEW'
- name of the COMIDA2 binary output file 38 BIN_FILE001 'SAMP_A.BIN' (revised data file of 8/12/95)
- Dose limits triggering first year crop disposal of the separate
Calculation IP-CALC-09-00265, Rev. 0, Att. A.1, Page 41
- milk and non-milk components of the diet, corresponding in purpose,
- more or less, to the MACCS 1.5 input variables PSCMLK and PSCOTH
- For NUREG-1150 calculations, the maximum allowable ground concentrations for
- production of milk and non-milk crops contaminated by an accident occurring
- in the growing season were derived based on an assumed maximum allowable
- the prior results, it is being assumed, for simplicity, that milk and
- non-milk crops contribute equally to the first year dose. Thus, the 5 rem
- effective dose limit used in NUREG-1150 is equally split between milk and
- thyroid limit is split into 7.5 and 7.5 rem for the milk and non-milk
- portions of the diet.
- effective thyroid (doses in sieverts) 39 DOSEMILK001 0.025 0.075 40 DOSEOTHR001 0.025 0.075
- Annual dose limits for the subsequent year's (i.e., after the first year)
- interdiction of BOTH the milk and non-milk (combined) components of the diet
- Note: the long-term food critera, GCMAXR, used for NUREG-1150 wre based on
- an ingestion dose integrated from zero to infinity. It is not possible to
- translate those parameter values into corresponding annual dose limits, as is
- required by the COMIDA2-based food model. The "total" dose limits used in
- NUREG-1150 for "root uptake", 0.5 rem effective and 1.5 rem thyroid, are used
- here as annual dose limits for interdiction of food production in years the
- years subsequent to the accident.
- effective thyroid (doses in sieverts) 41 DOSELONG001 0.005 0.015
- NUMBER OF NUCLIDES IN THE WATER INGESTION PATHWAY MODEL 42 CHNUMWPI001 4
- TABLE OF NUCLIDE DEFINITIONS IN THE WATER INGESTION PATHWAY MODEL
- IF A SITE DATA FILE IS DEFINED, THE DATA DEFINING THE WATERSHED INGESTION
- FACTOR IS SUPERSEDED BY THE CORRESPONDING DATA IN THE SITE DATA FILE
- INITIAL ANNUAL INGESTION FACTOR
- WATER WASHOFF WASHOFF ((Bq INGESTED)/
- NUCLIDE FRACTION RATE (Bq IN WATER))
- NAMWPI WSHFRI WSHRTA WINGF 43 CHWTRISO001 Sr-89 0.01 0.004 5.0E-6 44 CHWTRISO002 Sr-90 0.01 0.004 5.0E-6 45 CHWTRISO003 Cs-134 0.005 0.001 5.0E-6 46 CHWTRISO004 Cs-137 0.005 0.001 5.0E-6
- SPECIAL OPTIONS DATA BLOCK
- DETAILED PRINT OPTION CONTROL SWITCHES, LOOK AT THE CODE BEFORE TURNING ON!!
- KSWDSC 47 CHKSWTCH001 0
Calculation IP-CALC-09-00265, Rev. 0, Att. A.1, Page 42
- DEFINE THE TYPE 9 RESULTS
- LONG-TERM POPULATION DOSE IN A GIVEN REGION BROKEN DOWN BY THE 12 PATHWAYS
- NUMBER OF RESULTS OF THIS TYPE THAT ARE BEING REQUESTED
- FOR EACH RESULT YOU REQUEST, THE CODE WILL PRODUCE A SET OF 12 48 TYPE9NUMBER 1 (UP TO 10 ALLOWED)
- ORGNAM INNER OUTER 49 TYPE9OUT001 'L-EDEWBODY' 1 15 (0-50 MILES)
- ECONOMIC COST RESULTS IN A REGION BROKEN DOWN BY 12 TYPES OF COSTS
- NUMBER OF RESULTS OF THIS TYPE THAT ARE BEING REQUESTED
- FOR EACH RESULT YOU REQUEST, THE CODE WILL PRODUCE A SET OF 12 50 TYP10NUMBER 1 (UP TO 10 ALLOWED)
- INNER OUTER 51 TYP10OUT001 1 15 (0-50 MILES)
- DEFINE A FLAG THAT CONTROLS THE PRODUCTION OF THE ACTION DISTANCE RESULTS
- SPECIFYING A VALUE OF .TRUE. TURNS ON ALL 8 OF THE ACTION DISTANCE RESULTS,
- A VALUE OF .FALSE. WILL ELIMINATE THE ACTION DISTANCE RESULTS FROM THE OUTPUT.
52 TYP11FLAG11 .FALSE.
- IMPACTED AREA/POPULATION RESULTS IN A REGION BROKEN DOWN BY 6 TYPES OF IMPACTS
- NUMBER OF RESULTS OF THIS TYPE THAT ARE BEING REQUESTED
- FOR EACH RESULT YOU REQUEST, THE CODE WILL PRODUCE A SET OF 8 53 TYP12NUMBER 0 (UP TO 10 ALLOWED)
- INNER OUTER
- TYP12OUT001 1 15 (0-50 MILES)
- Maximal annual food ingestion dose to an individual, requested by IXOT13
- This result is calculated after accounting for temporary or
- permanent interdiction. It is only available for the "new" food model.
- NUMBER OF RESULTS OF THIS TYPE THAT ARE BEING REQUESTED 54 TYP13NUMBER 0 (UP TO 10 ALLOWED)
- IRAD13 is the radial spatial interval at which results are requested
- ORGN13 is the name of the organ for which results are requested
- (allowable values for ORGN13 are 'EFFECTIVE' or 'THYROID')
- IRAD13 ORGN13
- TYP13OUT001 2 EFFECTIVE
Calculation IP-CALC-09-00265, Rev. 0, Att. A.1, Page 43
- TYP13OUT002 4 EFFECTIVE
- TYP13OUT003 6 EFFECTIVE
- TYP13OUT004 8 EFFECTIVE
- TYP13OUT005 10 EFFECTIVE
- TYP13OUT006 12 EFFECTIVE
- TYP13OUT007 15 EFFECTIVE
- TYP13OUT008 2 THYROID
- TYP13OUT009 4 THYROID
- TYP13OUT010 6 THYROID
- TYP13OUT011 8 THYROID
- TYP13OUT012 10 THYROID
- TYP13OUT013 12 THYROID
- TYP13OUT014 15 THYROID
- TERMINATOR RECORD ENCOUNTERED -- END OF BASE CASE USER INPUT ********
USER INPUT PROCESSING
SUMMARY
- BASE CASE NUMBER OF RECORDS READ = 318 NUMBER OF BLANK OR COMMENT RECORDS READ = 263 NUMBER OF TERMINATOR RECORDS = 1 NUMBER OF RECORDS PROCESSED = 54 NUMBER OF PROCESSED RECORDS DUPLICATED = 0 NUMBER OF PROCESSED RECORDS SORTED = 54 COMIDA2 binary file header =
COMIDA2 01/14/2004 13:06:02 Version 1.11.1, 01/12/2004 COMIDA2 descriptive title =
MACCS File DOSDATA.INP: Changed by D. CHANIN25-JUN-92, 09:53:47 Seven new organs added with MACCS Version 1.5.11.1 A SITE DATA FILE IS BEING USED FOR BOTH "EARLY" AND "CHRONC" 7 CANCER EFFECTS ARE DEFINED IN THE MODEL.
INDEX CANCER EFFECT ORGAN ALPHA BETA CFRISK CIRISK 1 LEUKEMIA L-RED MARR 1.000E+00 0.000E+00 9.700E-03 0.000E+00 2 BONE L-BONE SUR 1.000E+00 0.000E+00 9.000E-04 0.000E+00 3 BREAST L-BREAST 1.000E+00 0.000E+00 5.400E-03 1.700E-02 4 LUNG L-LUNGS 1.000E+00 0.000E+00 1.550E-02 0.000E+00 5 THYROID L-THYROIDH 1.000E+00 0.000E+00 7.200E-04 7.200E-03 6 GI L-LOWER LI 1.000E+00 0.000E+00 3.360E-02 0.000E+00 7 OTHER L-EDEWBODY 1.000E+00 0.000E+00 2.760E-02 0.000E+00 TIME OF HOTSPOT RELOCATION IS 4.3200E+04.
TIME OF NORMAL RETURN IS 8.640E+04 AND THE EMERGENCY PHASE ENDS AT 6.048E+05.
GROUNDSHINE SHIELDING FACTOR = 0.400 RESUSPENSION PROTECTION FACTOR = 0.410 BREATHING RATE (CUBIC M/S) = 2.660E-04
Calculation IP-CALC-09-00265, Rev. 0, Att. A.1, Page 44 DISPERSION MODEL FLAG IS 2 WINDROSE PROBABILITIES BY WIND DIRECTION AND MET BIN NUMBER BIN 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 1 0.0826 0.0092 0.0092 0.0917 0.0826 0.1284 0.1651 0.1743 0.0917 0.0000 0.0092 0.0000 0.0000 0.0092 0.0000 0.1468 2 0.0659 0.0330 0.0220 0.0000 0.0220 0.0440 0.1538 0.0769 0.2747 0.0549 0.0000 0.0000 0.0000 0.0000 0.0000 0.2527 3 0.1147 0.0734 0.0550 0.0321 0.0092 0.0138 0.0046 0.0229 0.0321 0.0642 0.0596 0.0642 0.1147 0.1009 0.1422 0.0963 4 0.1583 0.0922 0.0414 0.0487 0.0472 0.0392 0.0465 0.0632 0.1089 0.1126 0.0712 0.0428 0.0196 0.0116 0.0254 0.0712 5 0.1236 0.0471 0.0206 0.0330 0.0671 0.1065 0.0989 0.1024 0.1919 0.1254 0.0288 0.0041 0.0018 0.0000 0.0029 0.0459 6 0.0750 0.0200 0.0069 0.0110 0.0399 0.1287 0.1913 0.1115 0.2230 0.1383 0.0172 0.0007 0.0000 0.0000 0.0007 0.0358 7 0.0548 0.0205 0.0137 0.0000 0.0205 0.0342 0.2740 0.0685 0.3425 0.1438 0.0000 0.0000 0.0000 0.0000 0.0000 0.0274 8 0.0000 0.0000 0.0000 0.0000 0.2000 0.0000 0.0000 0.2000 0.4000 0.2000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 9 0.1179 0.0866 0.0755 0.0368 0.0221 0.0276 0.0239 0.0313 0.0810 0.1087 0.0608 0.0589 0.0405 0.0718 0.0810 0.0755 10 0.1882 0.0935 0.0646 0.0256 0.0167 0.0067 0.0089 0.0100 0.0468 0.1904 0.1626 0.0512 0.0245 0.0100 0.0134 0.0869 11 0.2271 0.0542 0.0034 0.0034 0.0068 0.0068 0.0034 0.0136 0.0441 0.4237 0.1627 0.0034 0.0000 0.0000 0.0000 0.0475 12 0.2982 0.0526 0.0351 0.0000 0.0000 0.0175 0.0000 0.0175 0.2456 0.2105 0.0351 0.0000 0.0000 0.0000 0.0000 0.0877 13 0.0506 0.0169 0.0393 0.0000 0.0225 0.0337 0.0449 0.0899 0.2247 0.2079 0.0730 0.0562 0.0337 0.0112 0.0449 0.0506 14 0.0167 0.0083 0.0083 0.0042 0.0083 0.0000 0.0000 0.0042 0.0542 0.6750 0.1708 0.0333 0.0042 0.0042 0.0000 0.0083 15 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.7069 0.2759 0.0000 0.0000 0.0000 0.0000 0.0172 16 0.1429 0.0000 0.0000 0.0000 0.0000 0.1429 0.0000 0.0000 0.0000 0.4286 0.2857 0.0000 0.0000 0.0000 0.0000 0.0000 17 0.1472 0.0534 0.0245 0.0159 0.0101 0.0253 0.0108 0.0260 0.1212 0.2222 0.0765 0.0404 0.0382 0.0397 0.0339 0.1147 18 0.1472 0.0534 0.0245 0.0159 0.0101 0.0253 0.0108 0.0260 0.1212 0.2222 0.0765 0.0404 0.0382 0.0397 0.0339 0.1147 19 0.1472 0.0534 0.0245 0.0159 0.0101 0.0253 0.0108 0.0260 0.1212 0.2222 0.0765 0.0404 0.0382 0.0397 0.0339 0.1147 20 0.1472 0.0534 0.0245 0.0159 0.0101 0.0253 0.0108 0.0260 0.1212 0.2222 0.0765 0.0404 0.0382 0.0397 0.0339 0.1147 21 0.1472 0.0534 0.0245 0.0159 0.0101 0.0253 0.0108 0.0260 0.1212 0.2222 0.0765 0.0404 0.0382 0.0397 0.0339 0.1147 22 0.1472 0.0534 0.0245 0.0159 0.0101 0.0253 0.0108 0.0260 0.1212 0.2222 0.0765 0.0404 0.0382 0.0397 0.0339 0.1147 23 0.1472 0.0534 0.0245 0.0159 0.0101 0.0253 0.0108 0.0260 0.1212 0.2222 0.0765 0.0404 0.0382 0.0397 0.0339 0.1147 24 0.1472 0.0534 0.0245 0.0159 0.0101 0.0253 0.0108 0.0260 0.1212 0.2222 0.0765 0.0404 0.0382 0.0397 0.0339 0.1147 25 0.1472 0.0534 0.0245 0.0159 0.0101 0.0253 0.0108 0.0260 0.1212 0.2222 0.0765 0.0404 0.0382 0.0397 0.0339 0.1147 26 0.1472 0.0534 0.0245 0.0159 0.0101 0.0253 0.0108 0.0260 0.1212 0.2222 0.0765 0.0404 0.0382 0.0397 0.0339 0.1147 27 0.1472 0.0534 0.0245 0.0159 0.0101 0.0253 0.0108 0.0260 0.1212 0.2222 0.0765 0.0404 0.0382 0.0397 0.0339 0.1147 28 0.1472 0.0534 0.0245 0.0159 0.0101 0.0253 0.0108 0.0260 0.1212 0.2222 0.0765 0.0404 0.0382 0.0397 0.0339 0.1147 29 0.1472 0.0534 0.0245 0.0159 0.0101 0.0253 0.0108 0.0260 0.1212 0.2222 0.0765 0.0404 0.0382 0.0397 0.0339 0.1147 30 0.1472 0.0534 0.0245 0.0159 0.0101 0.0253 0.0108 0.0260 0.1212 0.2222 0.0765 0.0404 0.0382 0.0397 0.0339 0.1147 31 0.1472 0.0534 0.0245 0.0159 0.0101 0.0253 0.0108 0.0260 0.1212 0.2222 0.0765 0.0404 0.0382 0.0397 0.0339 0.1147 32 0.1472 0.0534 0.0245 0.0159 0.0101 0.0253 0.0108 0.0260 0.1212 0.2222 0.0765 0.0404 0.0382 0.0397 0.0339 0.1147 33 0.1472 0.0534 0.0245 0.0159 0.0101 0.0253 0.0108 0.0260 0.1212 0.2222 0.0765 0.0404 0.0382 0.0397 0.0339 0.1147 34 0.1472 0.0534 0.0245 0.0159 0.0101 0.0253 0.0108 0.0260 0.1212 0.2222 0.0765 0.0404 0.0382 0.0397 0.0339 0.1147 35 0.1472 0.0534 0.0245 0.0159 0.0101 0.0253 0.0108 0.0260 0.1212 0.2222 0.0765 0.0404 0.0382 0.0397 0.0339 0.1147 36 0.1472 0.0534 0.0245 0.0159 0.0101 0.0253 0.0108 0.0260 0.1212 0.2222 0.0765 0.0404 0.0382 0.0397 0.0339 0.1147 37 0.1472 0.0534 0.0245 0.0159 0.0101 0.0253 0.0108 0.0260 0.1212 0.2222 0.0765 0.0404 0.0382 0.0397 0.0339 0.1147 38 0.1472 0.0534 0.0245 0.0159 0.0101 0.0253 0.0108 0.0260 0.1212 0.2222 0.0765 0.0404 0.0382 0.0397 0.0339 0.1147 39 0.1472 0.0534 0.0245 0.0159 0.0101 0.0253 0.0108 0.0260 0.1212 0.2222 0.0765 0.0404 0.0382 0.0397 0.0339 0.1147 40 0.1472 0.0534 0.0245 0.0159 0.0101 0.0253 0.0108 0.0260 0.1212 0.2222 0.0765 0.0404 0.0382 0.0397 0.0339 0.1147 41 0.1279 0.0557 0.0301 0.0255 0.0346 0.0587 0.0717 0.0627 0.1402 0.1744 0.0677 0.0267 0.0182 0.0166 0.0209 0.0686 Processing a Site Data File with Header: MACCS2 Site Data File for Indian Point Energy Center SITE FILE
Calculation IP-CALC-09-00265, Rev. 0, Att. A.1, Page 45 THIS PROGRAM CURRENTLY ALLOWS THE GENERATION OF UP TO 394 RESULTS YOU HAVE REQUESTED 10 RESULTS FROM "EARLY" COMPOSED OF:
4 RESULTS OF TYPE 1 0 RESULTS OF TYPE 2 0 RESULTS OF TYPE 3 3 RESULTS OF TYPE 4 1 RESULTS OF TYPE 5 0 RESULTS OF TYPE 6 0 RESULTS OF TYPE 7 2 RESULTS OF TYPE 8 0 RESULTS OF TYPE A 0 RESULTS OF TYPE B YOU HAVE REQUESTED 30 RESULTS FROM "CHRONC" COMPOSED OF:
17 RESULTS OF TYPE 9 13 RESULTS OF TYPE 10 0 RESULTS OF TYPE 11 0 RESULTS OF TYPE 12 0 RESULTS OF TYPE 13 TRIAL DAY HOUR BIN PRBMET 1 152 16 1 3.11E-03
Calculation IP-CALC-09-00265, Rev. 0, Att. A.1, Page 46 WARNING!! WARNING!! WARNING!! WARNING!!
THE TOTAL RELEASE DURATION EXCEEDS 20 HOURS.
THIS MAY CAUSE ERRONEOUS RESULTS TO BE PRODUCED.
WARNING!! WARNING!! WARNING!! WARNING!!
Calculation IP-CALC-09-00265, Rev. 0, Att. A.1, Page 47 WARNING!! WARNING!! WARNING!! WARNING!!
A 10 HOUR RELEASE DURATION IS BEING USED BY ATMOS FOR CALCULATING THE EXPANSION FACTOR OF PLUME # 1 INSTEAD OF THE USER-SUPPLIED 24.00 HOURS WARNING!! WARNING!! WARNING!! WARNING!!
For Julian Day 152, selecting COMIDA2 results # 4 of 9 2 156 2 16 2.00E-04 For Julian Day 156, selecting COMIDA2 results # 4 of 9 3 156 14 2 2.60E-03 For Julian Day 156, selecting COMIDA2 results # 4 of 9 4 158 4 28 1.23E-03 For Julian Day 158, selecting COMIDA2 results # 4 of 9 5 158 14 23 1.86E-03 For Julian Day 158, selecting COMIDA2 results # 4 of 9 6 163 16 27 5.42E-04 For Julian Day 163, selecting COMIDA2 results # 4 of 9 7 163 17 25 4.00E-04 For Julian Day 163, selecting COMIDA2 results # 4 of 9 8 163 18 24 1.43E-04 For Julian Day 163, selecting COMIDA2 results # 4 of 9 9 163 22 18 1.34E-03 For Julian Day 163, selecting COMIDA2 results # 4 of 9 10 164 11 21 5.76E-03 For Julian Day 164, selecting COMIDA2 results # 4 of 9 11 165 13 28 1.23E-03 For Julian Day 165, selecting COMIDA2 results # 4 of 9 12 165 17 26 2.00E-04 For Julian Day 165, selecting COMIDA2 results # 4 of 9 13 165 20 24 1.43E-04 For Julian Day 165, selecting COMIDA2 results # 4 of 9 14 166 5 3 6.22E-03 For Julian Day 166, selecting COMIDA2 results # 4 of 9 15 166 12 4 3.93E-02 For Julian Day 166, selecting COMIDA2 results # 4 of 9 16 169 4 9 1.55E-02 For Julian Day 169, selecting COMIDA2 results # 5 of 9 17 170 10 30 1.14E-04 For Julian Day 170, selecting COMIDA2 results # 5 of 9 18 179 8 40 1.14E-03 For Julian Day 179, selecting COMIDA2 results # 5 of 9 19 179 12 38 1.71E-04 For Julian Day 179, selecting COMIDA2 results # 5 of 9 20 179 13 37 2.85E-04 For Julian Day 179, selecting COMIDA2 results # 5 of 9 21 179 14 35 8.56E-04 For Julian Day 179, selecting COMIDA2 results # 5 of 9 22 180 1 15 1.66E-03 For Julian Day 180, selecting COMIDA2 results # 5 of 9 23 180 21 10 2.56E-02 For Julian Day 180, selecting COMIDA2 results # 5 of 9 24 184 4 14 6.85E-03 For Julian Day 184, selecting COMIDA2 results # 5 of 9 25 193 9 6 4.15E-02 For Julian Day 193, selecting COMIDA2 results # 6 of 9 26 196 13 27 5.42E-04 For Julian Day 196, selecting COMIDA2 results # 6 of 9
Calculation IP-CALC-09-00265, Rev. 0, Att. A.1, Page 48 27 196 14 26 2.00E-04 For Julian Day 196, selecting COMIDA2 results # 6 of 9 28 197 3 24 1.43E-04 For Julian Day 197, selecting COMIDA2 results # 6 of 9 29 197 6 30 1.14E-04 For Julian Day 197, selecting COMIDA2 results # 6 of 9 30 197 7 29 5.99E-04 For Julian Day 197, selecting COMIDA2 results # 6 of 9 31 197 14 25 4.00E-04 For Julian Day 197, selecting COMIDA2 results # 6 of 9 32 199 24 34 8.28E-04 For Julian Day 199, selecting COMIDA2 results # 6 of 9 33 200 2 33 4.00E-04 For Julian Day 200, selecting COMIDA2 results # 6 of 9 34 200 6 31 2.00E-04 For Julian Day 200, selecting COMIDA2 results # 6 of 9 35 200 7 30 1.14E-04 For Julian Day 200, selecting COMIDA2 results # 6 of 9 36 203 12 28 1.23E-03 For Julian Day 203, selecting COMIDA2 results # 6 of 9 37 206 2 15 1.66E-03 For Julian Day 206, selecting COMIDA2 results # 6 of 9 38 206 7 11 8.42E-03 For Julian Day 206, selecting COMIDA2 results # 6 of 9 39 208 3 22 9.70E-03 For Julian Day 208, selecting COMIDA2 results # 6 of 9 40 212 5 20 2.08E-03 For Julian Day 212, selecting COMIDA2 results # 6 of 9 41 212 6 19 2.71E-03 For Julian Day 212, selecting COMIDA2 results # 6 of 9 42 212 13 17 8.28E-03 For Julian Day 212, selecting COMIDA2 results # 6 of 9 43 213 1 3 6.22E-03 For Julian Day 213, selecting COMIDA2 results # 6 of 9 44 216 17 39 6.28E-04 For Julian Day 216, selecting COMIDA2 results # 6 of 9 45 216 19 35 8.56E-04 For Julian Day 216, selecting COMIDA2 results # 6 of 9 46 218 15 5 4.85E-02 For Julian Day 218, selecting COMIDA2 results # 6 of 9 47 219 21 27 5.42E-04 For Julian Day 219, selecting COMIDA2 results # 6 of 9 48 219 22 26 2.00E-04 For Julian Day 219, selecting COMIDA2 results # 6 of 9 49 219 23 25 4.00E-04 For Julian Day 219, selecting COMIDA2 results # 6 of 9 50 228 16 40 1.14E-03 For Julian Day 228, selecting COMIDA2 results # 7 of 9 TRIAL DAY HOUR BIN PRBMET 51 228 22 39 6.28E-04 For Julian Day 228, selecting COMIDA2 results # 7 of 9 52 228 23 39 6.28E-04 For Julian Day 228, selecting COMIDA2 results # 7 of 9 53 229 1 38 1.71E-04 For Julian Day 229, selecting COMIDA2 results # 7 of 9 54 229 2 38 1.71E-04 For Julian Day 229, selecting COMIDA2 results # 7 of 9
Calculation IP-CALC-09-00265, Rev. 0, Att. A.1, Page 49 55 229 3 37 2.85E-04 For Julian Day 229, selecting COMIDA2 results # 7 of 9 56 245 12 24 1.43E-04 For Julian Day 245, selecting COMIDA2 results # 7 of 9 57 246 6 21 5.76E-03 For Julian Day 246, selecting COMIDA2 results # 7 of 9 58 250 2 11 8.42E-03 For Julian Day 250, selecting COMIDA2 results # 7 of 9 59 251 14 1 3.11E-03 For Julian Day 251, selecting COMIDA2 results # 7 of 9 60 256 23 33 4.00E-04 For Julian Day 256, selecting COMIDA2 results # 7 of 9 61 257 1 31 2.00E-04 For Julian Day 257, selecting COMIDA2 results # 8 of 9 62 258 17 40 1.14E-03 For Julian Day 258, selecting COMIDA2 results # 8 of 9 63 258 22 38 1.71E-04 For Julian Day 258, selecting COMIDA2 results # 8 of 9 64 258 23 37 2.85E-04 For Julian Day 258, selecting COMIDA2 results # 8 of 9 65 258 24 36 1.14E-04 For Julian Day 258, selecting COMIDA2 results # 8 of 9 66 259 2 29 5.99E-04 For Julian Day 259, selecting COMIDA2 results # 8 of 9 67 260 24 10 2.56E-02 For Julian Day 260, selecting COMIDA2 results # 8 of 9 68 263 9 40 1.14E-03 For Julian Day 263, selecting COMIDA2 results # 8 of 9 69 263 13 39 6.28E-04 For Julian Day 263, selecting COMIDA2 results # 8 of 9 70 263 18 35 8.56E-04 For Julian Day 263, selecting COMIDA2 results # 8 of 9 71 264 23 13 5.08E-03 For Julian Day 264, selecting COMIDA2 results # 8 of 9 72 271 19 9 1.55E-02 For Julian Day 271, selecting COMIDA2 results # 8 of 9 73 272 11 2 2.60E-03 For Julian Day 272, selecting COMIDA2 results # 8 of 9 74 273 15 4 3.93E-02 For Julian Day 273, selecting COMIDA2 results # 8 of 9 75 276 24 14 6.85E-03 For Julian Day 276, selecting COMIDA2 results # 8 of 9 76 282 12 1 3.11E-03 For Julian Day 282, selecting COMIDA2 results # 8 of 9 77 284 13 5 4.85E-02 For Julian Day 284, selecting COMIDA2 results # 8 of 9 78 288 6 13 5.08E-03 For Julian Day 288, selecting COMIDA2 results # 9 of 9 79 295 23 12 1.63E-03 For Julian Day 295, selecting COMIDA2 results # 9 of 9 80 299 2 15 1.66E-03 For Julian Day 299, selecting COMIDA2 results # 9 of 9 81 301 3 14 6.85E-03 For Julian Day 301, selecting COMIDA2 results # 9 of 9 82 302 10 7 4.17E-03 For Julian Day 302, selecting COMIDA2 results # 9 of 9 83 311 8 4 3.93E-02 For Julian Day 311, selecting COMIDA2 results # 9 of 9 84 314 10 22 9.70E-03
Calculation IP-CALC-09-00265, Rev. 0, Att. A.1, Page 50 For Julian Day 314, selecting COMIDA2 results # 9 of 9 85 314 18 20 2.08E-03 For Julian Day 314, selecting COMIDA2 results # 9 of 9 86 314 20 18 1.34E-03 For Julian Day 314, selecting COMIDA2 results # 9 of 9 87 315 9 23 1.86E-03 For Julian Day 315, selecting COMIDA2 results # 9 of 9 88 319 8 19 2.71E-03 For Julian Day 319, selecting COMIDA2 results # 9 of 9 89 319 16 25 4.00E-04 For Julian Day 319, selecting COMIDA2 results # 9 of 9 90 331 16 11 8.42E-03 For Julian Day 331, selecting COMIDA2 results # 9 of 9 91 334 22 19 2.71E-03 For Julian Day 334, selecting COMIDA2 results # 1 of 9 92 339 18 10 2.56E-02 For Julian Day 339, selecting COMIDA2 results # 1 of 9 93 347 10 8 1.43E-04 For Julian Day 347, selecting COMIDA2 results # 1 of 9 94 349 6 23 1.86E-03 For Julian Day 349, selecting COMIDA2 results # 1 of 9 95 352 8 27 5.42E-04 For Julian Day 352, selecting COMIDA2 results # 1 of 9 96 363 1 5 4.85E-02 For Julian Day 363, selecting COMIDA2 results # 1 of 9 97 364 6 6 4.15E-02 For Julian Day 364, selecting COMIDA2 results # 1 of 9 98 365 11 17 8.28E-03 For Julian Day 365, selecting COMIDA2 results # 1 of 9 99 4 13 34 8.28E-04 For Julian Day 4, selecting COMIDA2 results # 1 of 9 100 9 8 22 9.70E-03 For Julian Day 9, selecting COMIDA2 results # 1 of 9 TRIAL DAY HOUR BIN PRBMET 101 10 3 34 8.28E-04 For Julian Day 10, selecting COMIDA2 results # 1 of 9 102 10 8 33 4.00E-04 For Julian Day 10, selecting COMIDA2 results # 1 of 9 103 10 11 32 1.14E-04 For Julian Day 10, selecting COMIDA2 results # 1 of 9 104 10 13 31 2.00E-04 For Julian Day 10, selecting COMIDA2 results # 1 of 9 105 11 1 12 1.63E-03 For Julian Day 11, selecting COMIDA2 results # 1 of 9 106 13 16 7 4.17E-03 For Julian Day 13, selecting COMIDA2 results # 1 of 9 107 14 15 7 4.17E-03 For Julian Day 14, selecting COMIDA2 results # 1 of 9 108 16 23 8 1.43E-04 For Julian Day 16, selecting COMIDA2 results # 1 of 9 109 22 12 6 4.15E-02 For Julian Day 22, selecting COMIDA2 results # 1 of 9 110 25 11 8 1.43E-04 For Julian Day 25, selecting COMIDA2 results # 1 of 9 111 30 20 18 1.34E-03 For Julian Day 30, selecting COMIDA2 results # 1 of 9 112 38 2 12 1.63E-03
Calculation IP-CALC-09-00265, Rev. 0, Att. A.1, Page 51 For Julian Day 38, selecting COMIDA2 results # 2 of 9 113 40 2 11 8.42E-03 For Julian Day 40, selecting COMIDA2 results # 2 of 9 114 41 2 15 1.66E-03 For Julian Day 41, selecting COMIDA2 results # 2 of 9 115 44 5 16 2.00E-04 For Julian Day 44, selecting COMIDA2 results # 2 of 9 116 45 11 16 2.00E-04 For Julian Day 45, selecting COMIDA2 results # 2 of 9 117 49 8 21 5.76E-03 For Julian Day 49, selecting COMIDA2 results # 2 of 9 118 49 9 20 2.08E-03 For Julian Day 49, selecting COMIDA2 results # 2 of 9 119 49 17 17 8.28E-03 For Julian Day 49, selecting COMIDA2 results # 2 of 9 120 55 4 13 5.08E-03 For Julian Day 55, selecting COMIDA2 results # 2 of 9 121 56 2 28 1.23E-03 For Julian Day 56, selecting COMIDA2 results # 2 of 9 122 56 9 26 2.00E-04 For Julian Day 56, selecting COMIDA2 results # 2 of 9 123 58 2 9 1.55E-02 For Julian Day 58, selecting COMIDA2 results # 2 of 9 124 58 24 31 2.00E-04 For Julian Day 58, selecting COMIDA2 results # 2 of 9 125 59 1 30 1.14E-04 For Julian Day 59, selecting COMIDA2 results # 2 of 9 126 71 15 29 5.99E-04 For Julian Day 71, selecting COMIDA2 results # 2 of 9 127 78 4 8 1.43E-04 For Julian Day 78, selecting COMIDA2 results # 2 of 9 128 78 9 6 4.15E-02 For Julian Day 78, selecting COMIDA2 results # 2 of 9 129 86 3 13 5.08E-03 For Julian Day 86, selecting COMIDA2 results # 2 of 9 130 88 2 29 5.99E-04 For Julian Day 88, selecting COMIDA2 results # 2 of 9 131 95 6 19 2.71E-03 For Julian Day 95, selecting COMIDA2 results # 3 of 9 132 95 7 17 8.28E-03 For Julian Day 95, selecting COMIDA2 results # 3 of 9 133 95 10 12 1.63E-03 For Julian Day 95, selecting COMIDA2 results # 3 of 9 134 97 2 9 1.55E-02 For Julian Day 97, selecting COMIDA2 results # 3 of 9 135 97 3 10 2.56E-02 For Julian Day 97, selecting COMIDA2 results # 3 of 9 136 97 20 7 4.17E-03 For Julian Day 97, selecting COMIDA2 results # 3 of 9 137 99 5 3 6.22E-03 For Julian Day 99, selecting COMIDA2 results # 3 of 9 138 100 1 21 5.76E-03 For Julian Day 100, selecting COMIDA2 results # 3 of 9 139 105 16 2 2.60E-03 For Julian Day 105, selecting COMIDA2 results # 3 of 9 140 112 17 23 1.86E-03 For Julian Day 112, selecting COMIDA2 results # 3 of 9 141 120 6 16 2.00E-04 For Julian Day 120, selecting COMIDA2 results # 3 of 9
Calculation IP-CALC-09-00265, Rev. 0, Att. A.1, Page 52 142 124 3 14 6.85E-03 For Julian Day 124, selecting COMIDA2 results # 3 of 9 143 125 13 2 2.60E-03 For Julian Day 125, selecting COMIDA2 results # 3 of 9 144 127 11 4 3.93E-02 For Julian Day 127, selecting COMIDA2 results # 3 of 9 145 129 7 34 8.28E-04 For Julian Day 129, selecting COMIDA2 results # 3 of 9 146 129 12 33 4.00E-04 For Julian Day 129, selecting COMIDA2 results # 3 of 9 147 129 13 32 1.14E-04 For Julian Day 129, selecting COMIDA2 results # 3 of 9 148 131 17 20 2.08E-03 For Julian Day 131, selecting COMIDA2 results # 3 of 9 149 132 15 5 4.85E-02 For Julian Day 132, selecting COMIDA2 results # 3 of 9 150 134 21 35 8.56E-04 For Julian Day 134, selecting COMIDA2 results # 3 of 9 TRIAL DAY HOUR BIN PRBMET 151 137 14 1 3.11E-03 For Julian Day 137, selecting COMIDA2 results # 4 of 9 152 138 23 22 9.70E-03 For Julian Day 138, selecting COMIDA2 results # 4 of 9 153 141 9 18 1.34E-03 For Julian Day 141, selecting COMIDA2 results # 4 of 9 154 145 1 37 2.85E-04 For Julian Day 145, selecting COMIDA2 results # 4 of 9 155 151 1 3 6.22E-03 For Julian Day 151, selecting COMIDA2 results # 4 of 9
Calculation IP-CALC-09-00265, Rev. 0, Att. A.1, Page 53 WARNING!! WARNING!! WARNING!! WARNING!!
THE TOTAL RELEASE DURATION EXCEEDS 20 HOURS.
THIS MAY CAUSE ERRONEOUS RESULTS TO BE PRODUCED.
WARNING!! WARNING!! WARNING!! WARNING!!
Calculation IP-CALC-09-00265, Rev. 0, Att. A.1, Page 54 WARNING!! WARNING!! WARNING!! WARNING!!
A 10 HOUR RELEASE DURATION IS BEING USED BY ATMOS FOR CALCULATING THE EXPANSION FACTOR OF PLUME # 1 INSTEAD OF THE USER-SUPPLIED 22.89 HOURS WARNING!! WARNING!! WARNING!! WARNING!!
For Julian Day 152, selecting COMIDA2 results # 4 of 9 For Julian Day 156, selecting COMIDA2 results # 4 of 9 For Julian Day 156, selecting COMIDA2 results # 4 of 9 For Julian Day 158, selecting COMIDA2 results # 4 of 9 For Julian Day 158, selecting COMIDA2 results # 4 of 9 For Julian Day 163, selecting COMIDA2 results # 4 of 9 For Julian Day 163, selecting COMIDA2 results # 4 of 9 For Julian Day 163, selecting COMIDA2 results # 4 of 9 For Julian Day 163, selecting COMIDA2 results # 4 of 9 For Julian Day 164, selecting COMIDA2 results # 4 of 9 For Julian Day 165, selecting COMIDA2 results # 4 of 9 For Julian Day 165, selecting COMIDA2 results # 4 of 9 For Julian Day 165, selecting COMIDA2 results # 4 of 9 For Julian Day 166, selecting COMIDA2 results # 4 of 9 For Julian Day 166, selecting COMIDA2 results # 4 of 9 For Julian Day 169, selecting COMIDA2 results # 5 of 9 For Julian Day 170, selecting COMIDA2 results # 5 of 9 For Julian Day 179, selecting COMIDA2 results # 5 of 9 For Julian Day 179, selecting COMIDA2 results # 5 of 9 For Julian Day 179, selecting COMIDA2 results # 5 of 9 For Julian Day 179, selecting COMIDA2 results # 5 of 9 For Julian Day 180, selecting COMIDA2 results # 5 of 9 For Julian Day 180, selecting COMIDA2 results # 5 of 9 For Julian Day 184, selecting COMIDA2 results # 5 of 9 For Julian Day 193, selecting COMIDA2 results # 6 of 9 For Julian Day 196, selecting COMIDA2 results # 6 of 9 For Julian Day 196, selecting COMIDA2 results # 6 of 9 For Julian Day 197, selecting COMIDA2 results # 6 of 9 For Julian Day 197, selecting COMIDA2 results # 6 of 9 For Julian Day 197, selecting COMIDA2 results # 6 of 9 For Julian Day 197, selecting COMIDA2 results # 6 of 9 For Julian Day 199, selecting COMIDA2 results # 6 of 9 For Julian Day 200, selecting COMIDA2 results # 6 of 9 For Julian Day 200, selecting COMIDA2 results # 6 of 9 For Julian Day 200, selecting COMIDA2 results # 6 of 9 For Julian Day 203, selecting COMIDA2 results # 6 of 9 For Julian Day 206, selecting COMIDA2 results # 6 of 9 For Julian Day 206, selecting COMIDA2 results # 6 of 9 For Julian Day 208, selecting COMIDA2 results # 6 of 9 For Julian Day 212, selecting COMIDA2 results # 6 of 9 For Julian Day 212, selecting COMIDA2 results # 6 of 9 For Julian Day 212, selecting COMIDA2 results # 6 of 9 For Julian Day 213, selecting COMIDA2 results # 6 of 9 For Julian Day 216, selecting COMIDA2 results # 6 of 9 For Julian Day 216, selecting COMIDA2 results # 6 of 9 For Julian Day 218, selecting COMIDA2 results # 6 of 9 For Julian Day 219, selecting COMIDA2 results # 6 of 9 For Julian Day 219, selecting COMIDA2 results # 6 of 9 For Julian Day 219, selecting COMIDA2 results # 6 of 9 For Julian Day 228, selecting COMIDA2 results # 7 of 9 For Julian Day 228, selecting COMIDA2 results # 7 of 9
Calculation IP-CALC-09-00265, Rev. 0, Att. A.1, Page 55 For Julian Day 228, selecting COMIDA2 results # 7 of 9 For Julian Day 229, selecting COMIDA2 results # 7 of 9 For Julian Day 229, selecting COMIDA2 results # 7 of 9 For Julian Day 229, selecting COMIDA2 results # 7 of 9 For Julian Day 245, selecting COMIDA2 results # 7 of 9 For Julian Day 246, selecting COMIDA2 results # 7 of 9 For Julian Day 250, selecting COMIDA2 results # 7 of 9 For Julian Day 251, selecting COMIDA2 results # 7 of 9 For Julian Day 256, selecting COMIDA2 results # 7 of 9 For Julian Day 257, selecting COMIDA2 results # 8 of 9 For Julian Day 258, selecting COMIDA2 results # 8 of 9 For Julian Day 258, selecting COMIDA2 results # 8 of 9 For Julian Day 258, selecting COMIDA2 results # 8 of 9 For Julian Day 258, selecting COMIDA2 results # 8 of 9 For Julian Day 259, selecting COMIDA2 results # 8 of 9 For Julian Day 260, selecting COMIDA2 results # 8 of 9 For Julian Day 263, selecting COMIDA2 results # 8 of 9 For Julian Day 263, selecting COMIDA2 results # 8 of 9 For Julian Day 263, selecting COMIDA2 results # 8 of 9 For Julian Day 264, selecting COMIDA2 results # 8 of 9 For Julian Day 271, selecting COMIDA2 results # 8 of 9 For Julian Day 272, selecting COMIDA2 results # 8 of 9 For Julian Day 273, selecting COMIDA2 results # 8 of 9 For Julian Day 276, selecting COMIDA2 results # 8 of 9 For Julian Day 282, selecting COMIDA2 results # 8 of 9 For Julian Day 284, selecting COMIDA2 results # 8 of 9 For Julian Day 288, selecting COMIDA2 results # 9 of 9 For Julian Day 295, selecting COMIDA2 results # 9 of 9 For Julian Day 299, selecting COMIDA2 results # 9 of 9 For Julian Day 301, selecting COMIDA2 results # 9 of 9 For Julian Day 302, selecting COMIDA2 results # 9 of 9 For Julian Day 311, selecting COMIDA2 results # 9 of 9 For Julian Day 314, selecting COMIDA2 results # 9 of 9 For Julian Day 314, selecting COMIDA2 results # 9 of 9 For Julian Day 314, selecting COMIDA2 results # 9 of 9 For Julian Day 315, selecting COMIDA2 results # 9 of 9 For Julian Day 319, selecting COMIDA2 results # 9 of 9 For Julian Day 319, selecting COMIDA2 results # 9 of 9 For Julian Day 331, selecting COMIDA2 results # 9 of 9 For Julian Day 334, selecting COMIDA2 results # 1 of 9 For Julian Day 339, selecting COMIDA2 results # 1 of 9 For Julian Day 347, selecting COMIDA2 results # 1 of 9 For Julian Day 349, selecting COMIDA2 results # 1 of 9 For Julian Day 352, selecting COMIDA2 results # 1 of 9 For Julian Day 363, selecting COMIDA2 results # 1 of 9 For Julian Day 364, selecting COMIDA2 results # 1 of 9 For Julian Day 365, selecting COMIDA2 results # 1 of 9 For Julian Day 4, selecting COMIDA2 results # 1 of 9 For Julian Day 9, selecting COMIDA2 results # 1 of 9 For Julian Day 10, selecting COMIDA2 results # 1 of 9 For Julian Day 10, selecting COMIDA2 results # 1 of 9 For Julian Day 10, selecting COMIDA2 results # 1 of 9 For Julian Day 10, selecting COMIDA2 results # 1 of 9 For Julian Day 11, selecting COMIDA2 results # 1 of 9 For Julian Day 13, selecting COMIDA2 results # 1 of 9 For Julian Day 14, selecting COMIDA2 results # 1 of 9 For Julian Day 16, selecting COMIDA2 results # 1 of 9 For Julian Day 22, selecting COMIDA2 results # 1 of 9 For Julian Day 25, selecting COMIDA2 results # 1 of 9
Calculation IP-CALC-09-00265, Rev. 0, Att. A.1, Page 56 For Julian Day 30, selecting COMIDA2 results # 1 of 9 For Julian Day 38, selecting COMIDA2 results # 2 of 9 For Julian Day 40, selecting COMIDA2 results # 2 of 9 For Julian Day 41, selecting COMIDA2 results # 2 of 9 For Julian Day 44, selecting COMIDA2 results # 2 of 9 For Julian Day 45, selecting COMIDA2 results # 2 of 9 For Julian Day 49, selecting COMIDA2 results # 2 of 9 For Julian Day 49, selecting COMIDA2 results # 2 of 9 For Julian Day 49, selecting COMIDA2 results # 2 of 9 For Julian Day 55, selecting COMIDA2 results # 2 of 9 For Julian Day 56, selecting COMIDA2 results # 2 of 9 For Julian Day 56, selecting COMIDA2 results # 2 of 9 For Julian Day 58, selecting COMIDA2 results # 2 of 9 For Julian Day 58, selecting COMIDA2 results # 2 of 9 For Julian Day 59, selecting COMIDA2 results # 2 of 9 For Julian Day 71, selecting COMIDA2 results # 2 of 9 For Julian Day 78, selecting COMIDA2 results # 2 of 9 For Julian Day 78, selecting COMIDA2 results # 2 of 9 For Julian Day 86, selecting COMIDA2 results # 2 of 9 For Julian Day 88, selecting COMIDA2 results # 2 of 9 For Julian Day 95, selecting COMIDA2 results # 3 of 9 For Julian Day 95, selecting COMIDA2 results # 3 of 9 For Julian Day 95, selecting COMIDA2 results # 3 of 9 For Julian Day 97, selecting COMIDA2 results # 3 of 9 For Julian Day 97, selecting COMIDA2 results # 3 of 9 For Julian Day 97, selecting COMIDA2 results # 3 of 9 For Julian Day 99, selecting COMIDA2 results # 3 of 9 For Julian Day 100, selecting COMIDA2 results # 3 of 9 For Julian Day 105, selecting COMIDA2 results # 3 of 9 For Julian Day 112, selecting COMIDA2 results # 3 of 9 For Julian Day 120, selecting COMIDA2 results # 3 of 9 For Julian Day 124, selecting COMIDA2 results # 3 of 9 For Julian Day 125, selecting COMIDA2 results # 3 of 9 For Julian Day 127, selecting COMIDA2 results # 3 of 9 For Julian Day 129, selecting COMIDA2 results # 3 of 9 For Julian Day 129, selecting COMIDA2 results # 3 of 9 For Julian Day 129, selecting COMIDA2 results # 3 of 9 For Julian Day 131, selecting COMIDA2 results # 3 of 9 For Julian Day 132, selecting COMIDA2 results # 3 of 9 For Julian Day 134, selecting COMIDA2 results # 3 of 9 For Julian Day 137, selecting COMIDA2 results # 4 of 9 For Julian Day 138, selecting COMIDA2 results # 4 of 9 For Julian Day 141, selecting COMIDA2 results # 4 of 9 For Julian Day 145, selecting COMIDA2 results # 4 of 9 For Julian Day 151, selecting COMIDA2 results # 4 of 9
Calculation IP-CALC-09-00265, Rev. 0, Att. A.1, Page 57 WARNING!! WARNING!! WARNING!! WARNING!!
THE TOTAL RELEASE DURATION EXCEEDS 20 HOURS.
THIS MAY CAUSE ERRONEOUS RESULTS TO BE PRODUCED.
WARNING!! WARNING!! WARNING!! WARNING!!
Calculation IP-CALC-09-00265, Rev. 0, Att. A.1, Page 58 WARNING!! WARNING!! WARNING!! WARNING!!
A 10 HOUR RELEASE DURATION IS BEING USED BY ATMOS FOR CALCULATING THE EXPANSION FACTOR OF PLUME # 1 INSTEAD OF THE USER-SUPPLIED 24.00 HOURS WARNING!! WARNING!! WARNING!! WARNING!!
For Julian Day 152, selecting COMIDA2 results # 4 of 9 For Julian Day 156, selecting COMIDA2 results # 4 of 9 For Julian Day 156, selecting COMIDA2 results # 4 of 9 For Julian Day 158, selecting COMIDA2 results # 4 of 9 For Julian Day 158, selecting COMIDA2 results # 4 of 9 For Julian Day 163, selecting COMIDA2 results # 4 of 9 For Julian Day 163, selecting COMIDA2 results # 4 of 9 For Julian Day 163, selecting COMIDA2 results # 4 of 9 For Julian Day 163, selecting COMIDA2 results # 4 of 9 For Julian Day 164, selecting COMIDA2 results # 4 of 9 For Julian Day 165, selecting COMIDA2 results # 4 of 9 For Julian Day 165, selecting COMIDA2 results # 4 of 9 For Julian Day 165, selecting COMIDA2 results # 4 of 9 For Julian Day 166, selecting COMIDA2 results # 4 of 9 For Julian Day 166, selecting COMIDA2 results # 4 of 9 For Julian Day 169, selecting COMIDA2 results # 5 of 9 For Julian Day 170, selecting COMIDA2 results # 5 of 9 For Julian Day 179, selecting COMIDA2 results # 5 of 9 For Julian Day 179, selecting COMIDA2 results # 5 of 9 For Julian Day 179, selecting COMIDA2 results # 5 of 9 For Julian Day 179, selecting COMIDA2 results # 5 of 9 For Julian Day 180, selecting COMIDA2 results # 5 of 9 For Julian Day 180, selecting COMIDA2 results # 5 of 9 For Julian Day 184, selecting COMIDA2 results # 5 of 9 For Julian Day 193, selecting COMIDA2 results # 6 of 9 For Julian Day 196, selecting COMIDA2 results # 6 of 9 For Julian Day 196, selecting COMIDA2 results # 6 of 9 For Julian Day 197, selecting COMIDA2 results # 6 of 9 For Julian Day 197, selecting COMIDA2 results # 6 of 9 For Julian Day 197, selecting COMIDA2 results # 6 of 9 For Julian Day 197, selecting COMIDA2 results # 6 of 9 For Julian Day 199, selecting COMIDA2 results # 6 of 9 For Julian Day 200, selecting COMIDA2 results # 6 of 9 For Julian Day 200, selecting COMIDA2 results # 6 of 9 For Julian Day 200, selecting COMIDA2 results # 6 of 9 For Julian Day 203, selecting COMIDA2 results # 6 of 9 For Julian Day 206, selecting COMIDA2 results # 6 of 9 For Julian Day 206, selecting COMIDA2 results # 6 of 9 For Julian Day 208, selecting COMIDA2 results # 6 of 9 For Julian Day 212, selecting COMIDA2 results # 6 of 9 For Julian Day 212, selecting COMIDA2 results # 6 of 9 For Julian Day 212, selecting COMIDA2 results # 6 of 9 For Julian Day 213, selecting COMIDA2 results # 6 of 9 For Julian Day 216, selecting COMIDA2 results # 6 of 9 For Julian Day 216, selecting COMIDA2 results # 6 of 9 For Julian Day 218, selecting COMIDA2 results # 6 of 9 For Julian Day 219, selecting COMIDA2 results # 6 of 9 For Julian Day 219, selecting COMIDA2 results # 6 of 9 For Julian Day 219, selecting COMIDA2 results # 6 of 9 For Julian Day 228, selecting COMIDA2 results # 7 of 9 For Julian Day 228, selecting COMIDA2 results # 7 of 9
Calculation IP-CALC-09-00265, Rev. 0, Att. A.1, Page 59 For Julian Day 228, selecting COMIDA2 results # 7 of 9 For Julian Day 229, selecting COMIDA2 results # 7 of 9 For Julian Day 229, selecting COMIDA2 results # 7 of 9 For Julian Day 229, selecting COMIDA2 results # 7 of 9 For Julian Day 245, selecting COMIDA2 results # 7 of 9 For Julian Day 246, selecting COMIDA2 results # 7 of 9 For Julian Day 250, selecting COMIDA2 results # 7 of 9 For Julian Day 251, selecting COMIDA2 results # 7 of 9 For Julian Day 256, selecting COMIDA2 results # 7 of 9 For Julian Day 257, selecting COMIDA2 results # 8 of 9 For Julian Day 258, selecting COMIDA2 results # 8 of 9 For Julian Day 258, selecting COMIDA2 results # 8 of 9 For Julian Day 258, selecting COMIDA2 results # 8 of 9 For Julian Day 258, selecting COMIDA2 results # 8 of 9 For Julian Day 259, selecting COMIDA2 results # 8 of 9 For Julian Day 260, selecting COMIDA2 results # 8 of 9 For Julian Day 263, selecting COMIDA2 results # 8 of 9 For Julian Day 263, selecting COMIDA2 results # 8 of 9 For Julian Day 263, selecting COMIDA2 results # 8 of 9 For Julian Day 264, selecting COMIDA2 results # 8 of 9 For Julian Day 271, selecting COMIDA2 results # 8 of 9 For Julian Day 272, selecting COMIDA2 results # 8 of 9 For Julian Day 273, selecting COMIDA2 results # 8 of 9 For Julian Day 276, selecting COMIDA2 results # 8 of 9 For Julian Day 282, selecting COMIDA2 results # 8 of 9 For Julian Day 284, selecting COMIDA2 results # 8 of 9 For Julian Day 288, selecting COMIDA2 results # 9 of 9 For Julian Day 295, selecting COMIDA2 results # 9 of 9 For Julian Day 299, selecting COMIDA2 results # 9 of 9 For Julian Day 301, selecting COMIDA2 results # 9 of 9 For Julian Day 302, selecting COMIDA2 results # 9 of 9 For Julian Day 311, selecting COMIDA2 results # 9 of 9 For Julian Day 314, selecting COMIDA2 results # 9 of 9 For Julian Day 314, selecting COMIDA2 results # 9 of 9 For Julian Day 314, selecting COMIDA2 results # 9 of 9 For Julian Day 315, selecting COMIDA2 results # 9 of 9 For Julian Day 319, selecting COMIDA2 results # 9 of 9 For Julian Day 319, selecting COMIDA2 results # 9 of 9 For Julian Day 331, selecting COMIDA2 results # 9 of 9 For Julian Day 334, selecting COMIDA2 results # 1 of 9 For Julian Day 339, selecting COMIDA2 results # 1 of 9 For Julian Day 347, selecting COMIDA2 results # 1 of 9 For Julian Day 349, selecting COMIDA2 results # 1 of 9 For Julian Day 352, selecting COMIDA2 results # 1 of 9 For Julian Day 363, selecting COMIDA2 results # 1 of 9 For Julian Day 364, selecting COMIDA2 results # 1 of 9 For Julian Day 365, selecting COMIDA2 results # 1 of 9 For Julian Day 4, selecting COMIDA2 results # 1 of 9 For Julian Day 9, selecting COMIDA2 results # 1 of 9 For Julian Day 10, selecting COMIDA2 results # 1 of 9 For Julian Day 10, selecting COMIDA2 results # 1 of 9 For Julian Day 10, selecting COMIDA2 results # 1 of 9 For Julian Day 10, selecting COMIDA2 results # 1 of 9 For Julian Day 11, selecting COMIDA2 results # 1 of 9 For Julian Day 13, selecting COMIDA2 results # 1 of 9 For Julian Day 14, selecting COMIDA2 results # 1 of 9 For Julian Day 16, selecting COMIDA2 results # 1 of 9 For Julian Day 22, selecting COMIDA2 results # 1 of 9 For Julian Day 25, selecting COMIDA2 results # 1 of 9
Calculation IP-CALC-09-00265, Rev. 0, Att. A.1, Page 60 For Julian Day 30, selecting COMIDA2 results # 1 of 9 For Julian Day 38, selecting COMIDA2 results # 2 of 9 For Julian Day 40, selecting COMIDA2 results # 2 of 9 For Julian Day 41, selecting COMIDA2 results # 2 of 9 For Julian Day 44, selecting COMIDA2 results # 2 of 9 For Julian Day 45, selecting COMIDA2 results # 2 of 9 For Julian Day 49, selecting COMIDA2 results # 2 of 9 For Julian Day 49, selecting COMIDA2 results # 2 of 9 For Julian Day 49, selecting COMIDA2 results # 2 of 9 For Julian Day 55, selecting COMIDA2 results # 2 of 9 For Julian Day 56, selecting COMIDA2 results # 2 of 9 For Julian Day 56, selecting COMIDA2 results # 2 of 9 For Julian Day 58, selecting COMIDA2 results # 2 of 9 For Julian Day 58, selecting COMIDA2 results # 2 of 9 For Julian Day 59, selecting COMIDA2 results # 2 of 9 For Julian Day 71, selecting COMIDA2 results # 2 of 9 For Julian Day 78, selecting COMIDA2 results # 2 of 9 For Julian Day 78, selecting COMIDA2 results # 2 of 9 For Julian Day 86, selecting COMIDA2 results # 2 of 9 For Julian Day 88, selecting COMIDA2 results # 2 of 9 For Julian Day 95, selecting COMIDA2 results # 3 of 9 For Julian Day 95, selecting COMIDA2 results # 3 of 9 For Julian Day 95, selecting COMIDA2 results # 3 of 9 For Julian Day 97, selecting COMIDA2 results # 3 of 9 For Julian Day 97, selecting COMIDA2 results # 3 of 9 For Julian Day 97, selecting COMIDA2 results # 3 of 9 For Julian Day 99, selecting COMIDA2 results # 3 of 9 For Julian Day 100, selecting COMIDA2 results # 3 of 9 For Julian Day 105, selecting COMIDA2 results # 3 of 9 For Julian Day 112, selecting COMIDA2 results # 3 of 9 For Julian Day 120, selecting COMIDA2 results # 3 of 9 For Julian Day 124, selecting COMIDA2 results # 3 of 9 For Julian Day 125, selecting COMIDA2 results # 3 of 9 For Julian Day 127, selecting COMIDA2 results # 3 of 9 For Julian Day 129, selecting COMIDA2 results # 3 of 9 For Julian Day 129, selecting COMIDA2 results # 3 of 9 For Julian Day 129, selecting COMIDA2 results # 3 of 9 For Julian Day 131, selecting COMIDA2 results # 3 of 9 For Julian Day 132, selecting COMIDA2 results # 3 of 9 For Julian Day 134, selecting COMIDA2 results # 3 of 9 For Julian Day 137, selecting COMIDA2 results # 4 of 9 For Julian Day 138, selecting COMIDA2 results # 4 of 9 For Julian Day 141, selecting COMIDA2 results # 4 of 9 For Julian Day 145, selecting COMIDA2 results # 4 of 9 For Julian Day 151, selecting COMIDA2 results # 4 of 9
Calculation IP-CALC-09-00265, Rev. 0, Att. A.1, Page 61 WARNING!! WARNING!! WARNING!! WARNING!!
THE TOTAL RELEASE DURATION EXCEEDS 20 HOURS.
THIS MAY CAUSE ERRONEOUS RESULTS TO BE PRODUCED.
WARNING!! WARNING!! WARNING!! WARNING!!
Calculation IP-CALC-09-00265, Rev. 0, Att. A.1, Page 62 WARNING!! WARNING!! WARNING!! WARNING!!
A 10 HOUR RELEASE DURATION IS BEING USED BY ATMOS FOR CALCULATING THE EXPANSION FACTOR OF PLUME # 1 INSTEAD OF THE USER-SUPPLIED 24.00 HOURS WARNING!! WARNING!! WARNING!! WARNING!!
For Julian Day 152, selecting COMIDA2 results # 4 of 9 For Julian Day 156, selecting COMIDA2 results # 4 of 9 For Julian Day 156, selecting COMIDA2 results # 4 of 9 For Julian Day 158, selecting COMIDA2 results # 4 of 9 For Julian Day 158, selecting COMIDA2 results # 4 of 9 For Julian Day 163, selecting COMIDA2 results # 4 of 9 For Julian Day 163, selecting COMIDA2 results # 4 of 9 For Julian Day 163, selecting COMIDA2 results # 4 of 9 For Julian Day 163, selecting COMIDA2 results # 4 of 9 For Julian Day 164, selecting COMIDA2 results # 4 of 9 For Julian Day 165, selecting COMIDA2 results # 4 of 9 For Julian Day 165, selecting COMIDA2 results # 4 of 9 For Julian Day 165, selecting COMIDA2 results # 4 of 9 For Julian Day 166, selecting COMIDA2 results # 4 of 9 For Julian Day 166, selecting COMIDA2 results # 4 of 9 For Julian Day 169, selecting COMIDA2 results # 5 of 9 For Julian Day 170, selecting COMIDA2 results # 5 of 9 For Julian Day 179, selecting COMIDA2 results # 5 of 9 For Julian Day 179, selecting COMIDA2 results # 5 of 9 For Julian Day 179, selecting COMIDA2 results # 5 of 9 For Julian Day 179, selecting COMIDA2 results # 5 of 9 For Julian Day 180, selecting COMIDA2 results # 5 of 9 For Julian Day 180, selecting COMIDA2 results # 5 of 9 For Julian Day 184, selecting COMIDA2 results # 5 of 9 For Julian Day 193, selecting COMIDA2 results # 6 of 9 For Julian Day 196, selecting COMIDA2 results # 6 of 9 For Julian Day 196, selecting COMIDA2 results # 6 of 9 For Julian Day 197, selecting COMIDA2 results # 6 of 9 For Julian Day 197, selecting COMIDA2 results # 6 of 9 For Julian Day 197, selecting COMIDA2 results # 6 of 9 For Julian Day 197, selecting COMIDA2 results # 6 of 9 For Julian Day 199, selecting COMIDA2 results # 6 of 9 For Julian Day 200, selecting COMIDA2 results # 6 of 9 For Julian Day 200, selecting COMIDA2 results # 6 of 9 For Julian Day 200, selecting COMIDA2 results # 6 of 9 For Julian Day 203, selecting COMIDA2 results # 6 of 9 For Julian Day 206, selecting COMIDA2 results # 6 of 9 For Julian Day 206, selecting COMIDA2 results # 6 of 9 For Julian Day 208, selecting COMIDA2 results # 6 of 9 For Julian Day 212, selecting COMIDA2 results # 6 of 9 For Julian Day 212, selecting COMIDA2 results # 6 of 9 For Julian Day 212, selecting COMIDA2 results # 6 of 9 For Julian Day 213, selecting COMIDA2 results # 6 of 9 For Julian Day 216, selecting COMIDA2 results # 6 of 9 For Julian Day 216, selecting COMIDA2 results # 6 of 9 For Julian Day 218, selecting COMIDA2 results # 6 of 9 For Julian Day 219, selecting COMIDA2 results # 6 of 9 For Julian Day 219, selecting COMIDA2 results # 6 of 9 For Julian Day 219, selecting COMIDA2 results # 6 of 9 For Julian Day 228, selecting COMIDA2 results # 7 of 9 For Julian Day 228, selecting COMIDA2 results # 7 of 9
Calculation IP-CALC-09-00265, Rev. 0, Att. A.1, Page 63 For Julian Day 228, selecting COMIDA2 results # 7 of 9 For Julian Day 229, selecting COMIDA2 results # 7 of 9 For Julian Day 229, selecting COMIDA2 results # 7 of 9 For Julian Day 229, selecting COMIDA2 results # 7 of 9 For Julian Day 245, selecting COMIDA2 results # 7 of 9 For Julian Day 246, selecting COMIDA2 results # 7 of 9 For Julian Day 250, selecting COMIDA2 results # 7 of 9 For Julian Day 251, selecting COMIDA2 results # 7 of 9 For Julian Day 256, selecting COMIDA2 results # 7 of 9 For Julian Day 257, selecting COMIDA2 results # 8 of 9 For Julian Day 258, selecting COMIDA2 results # 8 of 9 For Julian Day 258, selecting COMIDA2 results # 8 of 9 For Julian Day 258, selecting COMIDA2 results # 8 of 9 For Julian Day 258, selecting COMIDA2 results # 8 of 9 For Julian Day 259, selecting COMIDA2 results # 8 of 9 For Julian Day 260, selecting COMIDA2 results # 8 of 9 For Julian Day 263, selecting COMIDA2 results # 8 of 9 For Julian Day 263, selecting COMIDA2 results # 8 of 9 For Julian Day 263, selecting COMIDA2 results # 8 of 9 For Julian Day 264, selecting COMIDA2 results # 8 of 9 For Julian Day 271, selecting COMIDA2 results # 8 of 9 For Julian Day 272, selecting COMIDA2 results # 8 of 9 For Julian Day 273, selecting COMIDA2 results # 8 of 9 For Julian Day 276, selecting COMIDA2 results # 8 of 9 For Julian Day 282, selecting COMIDA2 results # 8 of 9 For Julian Day 284, selecting COMIDA2 results # 8 of 9 For Julian Day 288, selecting COMIDA2 results # 9 of 9 For Julian Day 295, selecting COMIDA2 results # 9 of 9 For Julian Day 299, selecting COMIDA2 results # 9 of 9 For Julian Day 301, selecting COMIDA2 results # 9 of 9 For Julian Day 302, selecting COMIDA2 results # 9 of 9 For Julian Day 311, selecting COMIDA2 results # 9 of 9 For Julian Day 314, selecting COMIDA2 results # 9 of 9 For Julian Day 314, selecting COMIDA2 results # 9 of 9 For Julian Day 314, selecting COMIDA2 results # 9 of 9 For Julian Day 315, selecting COMIDA2 results # 9 of 9 For Julian Day 319, selecting COMIDA2 results # 9 of 9 For Julian Day 319, selecting COMIDA2 results # 9 of 9 For Julian Day 331, selecting COMIDA2 results # 9 of 9 For Julian Day 334, selecting COMIDA2 results # 1 of 9 For Julian Day 339, selecting COMIDA2 results # 1 of 9 For Julian Day 347, selecting COMIDA2 results # 1 of 9 For Julian Day 349, selecting COMIDA2 results # 1 of 9 For Julian Day 352, selecting COMIDA2 results # 1 of 9 For Julian Day 363, selecting COMIDA2 results # 1 of 9 For Julian Day 364, selecting COMIDA2 results # 1 of 9 For Julian Day 365, selecting COMIDA2 results # 1 of 9 For Julian Day 4, selecting COMIDA2 results # 1 of 9 For Julian Day 9, selecting COMIDA2 results # 1 of 9 For Julian Day 10, selecting COMIDA2 results # 1 of 9 For Julian Day 10, selecting COMIDA2 results # 1 of 9 For Julian Day 10, selecting COMIDA2 results # 1 of 9 For Julian Day 10, selecting COMIDA2 results # 1 of 9 For Julian Day 11, selecting COMIDA2 results # 1 of 9 For Julian Day 13, selecting COMIDA2 results # 1 of 9 For Julian Day 14, selecting COMIDA2 results # 1 of 9 For Julian Day 16, selecting COMIDA2 results # 1 of 9 For Julian Day 22, selecting COMIDA2 results # 1 of 9 For Julian Day 25, selecting COMIDA2 results # 1 of 9
Calculation IP-CALC-09-00265, Rev. 0, Att. A.1, Page 64 For Julian Day 30, selecting COMIDA2 results # 1 of 9 For Julian Day 38, selecting COMIDA2 results # 2 of 9 For Julian Day 40, selecting COMIDA2 results # 2 of 9 For Julian Day 41, selecting COMIDA2 results # 2 of 9 For Julian Day 44, selecting COMIDA2 results # 2 of 9 For Julian Day 45, selecting COMIDA2 results # 2 of 9 For Julian Day 49, selecting COMIDA2 results # 2 of 9 For Julian Day 49, selecting COMIDA2 results # 2 of 9 For Julian Day 49, selecting COMIDA2 results # 2 of 9 For Julian Day 55, selecting COMIDA2 results # 2 of 9 For Julian Day 56, selecting COMIDA2 results # 2 of 9 For Julian Day 56, selecting COMIDA2 results # 2 of 9 For Julian Day 58, selecting COMIDA2 results # 2 of 9 For Julian Day 58, selecting COMIDA2 results # 2 of 9 For Julian Day 59, selecting COMIDA2 results # 2 of 9 For Julian Day 71, selecting COMIDA2 results # 2 of 9 For Julian Day 78, selecting COMIDA2 results # 2 of 9 For Julian Day 78, selecting COMIDA2 results # 2 of 9 For Julian Day 86, selecting COMIDA2 results # 2 of 9 For Julian Day 88, selecting COMIDA2 results # 2 of 9 For Julian Day 95, selecting COMIDA2 results # 3 of 9 For Julian Day 95, selecting COMIDA2 results # 3 of 9 For Julian Day 95, selecting COMIDA2 results # 3 of 9 For Julian Day 97, selecting COMIDA2 results # 3 of 9 For Julian Day 97, selecting COMIDA2 results # 3 of 9 For Julian Day 97, selecting COMIDA2 results # 3 of 9 For Julian Day 99, selecting COMIDA2 results # 3 of 9 For Julian Day 100, selecting COMIDA2 results # 3 of 9 For Julian Day 105, selecting COMIDA2 results # 3 of 9 For Julian Day 112, selecting COMIDA2 results # 3 of 9 For Julian Day 120, selecting COMIDA2 results # 3 of 9 For Julian Day 124, selecting COMIDA2 results # 3 of 9 For Julian Day 125, selecting COMIDA2 results # 3 of 9 For Julian Day 127, selecting COMIDA2 results # 3 of 9 For Julian Day 129, selecting COMIDA2 results # 3 of 9 For Julian Day 129, selecting COMIDA2 results # 3 of 9 For Julian Day 129, selecting COMIDA2 results # 3 of 9 For Julian Day 131, selecting COMIDA2 results # 3 of 9 For Julian Day 132, selecting COMIDA2 results # 3 of 9 For Julian Day 134, selecting COMIDA2 results # 3 of 9 For Julian Day 137, selecting COMIDA2 results # 4 of 9 For Julian Day 138, selecting COMIDA2 results # 4 of 9 For Julian Day 141, selecting COMIDA2 results # 4 of 9 For Julian Day 145, selecting COMIDA2 results # 4 of 9 For Julian Day 151, selecting COMIDA2 results # 4 of 9
Calculation IP-CALC-09-00265, Rev. 0, Att. A.1, Page 65 WARNING!! WARNING!! WARNING!! WARNING!!
THE TOTAL RELEASE DURATION EXCEEDS 20 HOURS.
THIS MAY CAUSE ERRONEOUS RESULTS TO BE PRODUCED.
WARNING!! WARNING!! WARNING!! WARNING!!
Calculation IP-CALC-09-00265, Rev. 0, Att. A.1, Page 66 WARNING!! WARNING!! WARNING!! WARNING!!
A 10 HOUR RELEASE DURATION IS BEING USED BY ATMOS FOR CALCULATING THE EXPANSION FACTOR OF PLUME # 1 INSTEAD OF THE USER-SUPPLIED 24.00 HOURS WARNING!! WARNING!! WARNING!! WARNING!!
For Julian Day 152, selecting COMIDA2 results # 4 of 9 For Julian Day 156, selecting COMIDA2 results # 4 of 9 For Julian Day 156, selecting COMIDA2 results # 4 of 9 For Julian Day 158, selecting COMIDA2 results # 4 of 9 For Julian Day 158, selecting COMIDA2 results # 4 of 9 For Julian Day 163, selecting COMIDA2 results # 4 of 9 For Julian Day 163, selecting COMIDA2 results # 4 of 9 For Julian Day 163, selecting COMIDA2 results # 4 of 9 For Julian Day 163, selecting COMIDA2 results # 4 of 9 For Julian Day 164, selecting COMIDA2 results # 4 of 9 For Julian Day 165, selecting COMIDA2 results # 4 of 9 For Julian Day 165, selecting COMIDA2 results # 4 of 9 For Julian Day 165, selecting COMIDA2 results # 4 of 9 For Julian Day 166, selecting COMIDA2 results # 4 of 9 For Julian Day 166, selecting COMIDA2 results # 4 of 9 For Julian Day 169, selecting COMIDA2 results # 5 of 9 For Julian Day 170, selecting COMIDA2 results # 5 of 9 For Julian Day 179, selecting COMIDA2 results # 5 of 9 For Julian Day 179, selecting COMIDA2 results # 5 of 9 For Julian Day 179, selecting COMIDA2 results # 5 of 9 For Julian Day 179, selecting COMIDA2 results # 5 of 9 For Julian Day 180, selecting COMIDA2 results # 5 of 9 For Julian Day 180, selecting COMIDA2 results # 5 of 9 For Julian Day 184, selecting COMIDA2 results # 5 of 9 For Julian Day 193, selecting COMIDA2 results # 6 of 9 For Julian Day 196, selecting COMIDA2 results # 6 of 9 For Julian Day 196, selecting COMIDA2 results # 6 of 9 For Julian Day 197, selecting COMIDA2 results # 6 of 9 For Julian Day 197, selecting COMIDA2 results # 6 of 9 For Julian Day 197, selecting COMIDA2 results # 6 of 9 For Julian Day 197, selecting COMIDA2 results # 6 of 9 For Julian Day 199, selecting COMIDA2 results # 6 of 9 For Julian Day 200, selecting COMIDA2 results # 6 of 9 For Julian Day 200, selecting COMIDA2 results # 6 of 9 For Julian Day 200, selecting COMIDA2 results # 6 of 9 For Julian Day 203, selecting COMIDA2 results # 6 of 9 For Julian Day 206, selecting COMIDA2 results # 6 of 9 For Julian Day 206, selecting COMIDA2 results # 6 of 9 For Julian Day 208, selecting COMIDA2 results # 6 of 9 For Julian Day 212, selecting COMIDA2 results # 6 of 9 For Julian Day 212, selecting COMIDA2 results # 6 of 9 For Julian Day 212, selecting COMIDA2 results # 6 of 9 For Julian Day 213, selecting COMIDA2 results # 6 of 9 For Julian Day 216, selecting COMIDA2 results # 6 of 9 For Julian Day 216, selecting COMIDA2 results # 6 of 9 For Julian Day 218, selecting COMIDA2 results # 6 of 9 For Julian Day 219, selecting COMIDA2 results # 6 of 9 For Julian Day 219, selecting COMIDA2 results # 6 of 9 For Julian Day 219, selecting COMIDA2 results # 6 of 9 For Julian Day 228, selecting COMIDA2 results # 7 of 9 For Julian Day 228, selecting COMIDA2 results # 7 of 9
Calculation IP-CALC-09-00265, Rev. 0, Att. A.1, Page 67 For Julian Day 228, selecting COMIDA2 results # 7 of 9 For Julian Day 229, selecting COMIDA2 results # 7 of 9 For Julian Day 229, selecting COMIDA2 results # 7 of 9 For Julian Day 229, selecting COMIDA2 results # 7 of 9 For Julian Day 245, selecting COMIDA2 results # 7 of 9 For Julian Day 246, selecting COMIDA2 results # 7 of 9 For Julian Day 250, selecting COMIDA2 results # 7 of 9 For Julian Day 251, selecting COMIDA2 results # 7 of 9 For Julian Day 256, selecting COMIDA2 results # 7 of 9 For Julian Day 257, selecting COMIDA2 results # 8 of 9 For Julian Day 258, selecting COMIDA2 results # 8 of 9 For Julian Day 258, selecting COMIDA2 results # 8 of 9 For Julian Day 258, selecting COMIDA2 results # 8 of 9 For Julian Day 258, selecting COMIDA2 results # 8 of 9 For Julian Day 259, selecting COMIDA2 results # 8 of 9 For Julian Day 260, selecting COMIDA2 results # 8 of 9 For Julian Day 263, selecting COMIDA2 results # 8 of 9 For Julian Day 263, selecting COMIDA2 results # 8 of 9 For Julian Day 263, selecting COMIDA2 results # 8 of 9 For Julian Day 264, selecting COMIDA2 results # 8 of 9 For Julian Day 271, selecting COMIDA2 results # 8 of 9 For Julian Day 272, selecting COMIDA2 results # 8 of 9 For Julian Day 273, selecting COMIDA2 results # 8 of 9 For Julian Day 276, selecting COMIDA2 results # 8 of 9 For Julian Day 282, selecting COMIDA2 results # 8 of 9 For Julian Day 284, selecting COMIDA2 results # 8 of 9 For Julian Day 288, selecting COMIDA2 results # 9 of 9 For Julian Day 295, selecting COMIDA2 results # 9 of 9 For Julian Day 299, selecting COMIDA2 results # 9 of 9 For Julian Day 301, selecting COMIDA2 results # 9 of 9 For Julian Day 302, selecting COMIDA2 results # 9 of 9 For Julian Day 311, selecting COMIDA2 results # 9 of 9 For Julian Day 314, selecting COMIDA2 results # 9 of 9 For Julian Day 314, selecting COMIDA2 results # 9 of 9 For Julian Day 314, selecting COMIDA2 results # 9 of 9 For Julian Day 315, selecting COMIDA2 results # 9 of 9 For Julian Day 319, selecting COMIDA2 results # 9 of 9 For Julian Day 319, selecting COMIDA2 results # 9 of 9 For Julian Day 331, selecting COMIDA2 results # 9 of 9 For Julian Day 334, selecting COMIDA2 results # 1 of 9 For Julian Day 339, selecting COMIDA2 results # 1 of 9 For Julian Day 347, selecting COMIDA2 results # 1 of 9 For Julian Day 349, selecting COMIDA2 results # 1 of 9 For Julian Day 352, selecting COMIDA2 results # 1 of 9 For Julian Day 363, selecting COMIDA2 results # 1 of 9 For Julian Day 364, selecting COMIDA2 results # 1 of 9 For Julian Day 365, selecting COMIDA2 results # 1 of 9 For Julian Day 4, selecting COMIDA2 results # 1 of 9 For Julian Day 9, selecting COMIDA2 results # 1 of 9 For Julian Day 10, selecting COMIDA2 results # 1 of 9 For Julian Day 10, selecting COMIDA2 results # 1 of 9 For Julian Day 10, selecting COMIDA2 results # 1 of 9 For Julian Day 10, selecting COMIDA2 results # 1 of 9 For Julian Day 11, selecting COMIDA2 results # 1 of 9 For Julian Day 13, selecting COMIDA2 results # 1 of 9 For Julian Day 14, selecting COMIDA2 results # 1 of 9 For Julian Day 16, selecting COMIDA2 results # 1 of 9 For Julian Day 22, selecting COMIDA2 results # 1 of 9 For Julian Day 25, selecting COMIDA2 results # 1 of 9
Calculation IP-CALC-09-00265, Rev. 0, Att. A.1, Page 68 For Julian Day 30, selecting COMIDA2 results # 1 of 9 For Julian Day 38, selecting COMIDA2 results # 2 of 9 For Julian Day 40, selecting COMIDA2 results # 2 of 9 For Julian Day 41, selecting COMIDA2 results # 2 of 9 For Julian Day 44, selecting COMIDA2 results # 2 of 9 For Julian Day 45, selecting COMIDA2 results # 2 of 9 For Julian Day 49, selecting COMIDA2 results # 2 of 9 For Julian Day 49, selecting COMIDA2 results # 2 of 9 For Julian Day 49, selecting COMIDA2 results # 2 of 9 For Julian Day 55, selecting COMIDA2 results # 2 of 9 For Julian Day 56, selecting COMIDA2 results # 2 of 9 For Julian Day 56, selecting COMIDA2 results # 2 of 9 For Julian Day 58, selecting COMIDA2 results # 2 of 9 For Julian Day 58, selecting COMIDA2 results # 2 of 9 For Julian Day 59, selecting COMIDA2 results # 2 of 9 For Julian Day 71, selecting COMIDA2 results # 2 of 9 For Julian Day 78, selecting COMIDA2 results # 2 of 9 For Julian Day 78, selecting COMIDA2 results # 2 of 9 For Julian Day 86, selecting COMIDA2 results # 2 of 9 For Julian Day 88, selecting COMIDA2 results # 2 of 9 For Julian Day 95, selecting COMIDA2 results # 3 of 9 For Julian Day 95, selecting COMIDA2 results # 3 of 9 For Julian Day 95, selecting COMIDA2 results # 3 of 9 For Julian Day 97, selecting COMIDA2 results # 3 of 9 For Julian Day 97, selecting COMIDA2 results # 3 of 9 For Julian Day 97, selecting COMIDA2 results # 3 of 9 For Julian Day 99, selecting COMIDA2 results # 3 of 9 For Julian Day 100, selecting COMIDA2 results # 3 of 9 For Julian Day 105, selecting COMIDA2 results # 3 of 9 For Julian Day 112, selecting COMIDA2 results # 3 of 9 For Julian Day 120, selecting COMIDA2 results # 3 of 9 For Julian Day 124, selecting COMIDA2 results # 3 of 9 For Julian Day 125, selecting COMIDA2 results # 3 of 9 For Julian Day 127, selecting COMIDA2 results # 3 of 9 For Julian Day 129, selecting COMIDA2 results # 3 of 9 For Julian Day 129, selecting COMIDA2 results # 3 of 9 For Julian Day 129, selecting COMIDA2 results # 3 of 9 For Julian Day 131, selecting COMIDA2 results # 3 of 9 For Julian Day 132, selecting COMIDA2 results # 3 of 9 For Julian Day 134, selecting COMIDA2 results # 3 of 9 For Julian Day 137, selecting COMIDA2 results # 4 of 9 For Julian Day 138, selecting COMIDA2 results # 4 of 9 For Julian Day 141, selecting COMIDA2 results # 4 of 9 For Julian Day 145, selecting COMIDA2 results # 4 of 9 For Julian Day 151, selecting COMIDA2 results # 4 of 9
Calculation IP-CALC-09-00265, Rev. 0, Att. A.1, Page 69 WARNING!! WARNING!! WARNING!! WARNING!!
THE TOTAL RELEASE DURATION EXCEEDS 20 HOURS.
THIS MAY CAUSE ERRONEOUS RESULTS TO BE PRODUCED.
WARNING!! WARNING!! WARNING!! WARNING!!
Calculation IP-CALC-09-00265, Rev. 0, Att. A.1, Page 70 WARNING!! WARNING!! WARNING!! WARNING!!
A 10 HOUR RELEASE DURATION IS BEING USED BY ATMOS FOR CALCULATING THE EXPANSION FACTOR OF PLUME # 1 INSTEAD OF THE USER-SUPPLIED 24.00 HOURS WARNING!! WARNING!! WARNING!! WARNING!!
For Julian Day 152, selecting COMIDA2 results # 4 of 9 For Julian Day 156, selecting COMIDA2 results # 4 of 9 For Julian Day 156, selecting COMIDA2 results # 4 of 9 For Julian Day 158, selecting COMIDA2 results # 4 of 9 For Julian Day 158, selecting COMIDA2 results # 4 of 9 For Julian Day 163, selecting COMIDA2 results # 4 of 9 For Julian Day 163, selecting COMIDA2 results # 4 of 9 For Julian Day 163, selecting COMIDA2 results # 4 of 9 For Julian Day 163, selecting COMIDA2 results # 4 of 9 For Julian Day 164, selecting COMIDA2 results # 4 of 9 For Julian Day 165, selecting COMIDA2 results # 4 of 9 For Julian Day 165, selecting COMIDA2 results # 4 of 9 For Julian Day 165, selecting COMIDA2 results # 4 of 9 For Julian Day 166, selecting COMIDA2 results # 4 of 9 For Julian Day 166, selecting COMIDA2 results # 4 of 9 For Julian Day 169, selecting COMIDA2 results # 5 of 9 For Julian Day 170, selecting COMIDA2 results # 5 of 9 For Julian Day 179, selecting COMIDA2 results # 5 of 9 For Julian Day 179, selecting COMIDA2 results # 5 of 9 For Julian Day 179, selecting COMIDA2 results # 5 of 9 For Julian Day 179, selecting COMIDA2 results # 5 of 9 For Julian Day 180, selecting COMIDA2 results # 5 of 9 For Julian Day 180, selecting COMIDA2 results # 5 of 9 For Julian Day 184, selecting COMIDA2 results # 5 of 9 For Julian Day 193, selecting COMIDA2 results # 6 of 9 For Julian Day 196, selecting COMIDA2 results # 6 of 9 For Julian Day 196, selecting COMIDA2 results # 6 of 9 For Julian Day 197, selecting COMIDA2 results # 6 of 9 For Julian Day 197, selecting COMIDA2 results # 6 of 9 For Julian Day 197, selecting COMIDA2 results # 6 of 9 For Julian Day 197, selecting COMIDA2 results # 6 of 9 For Julian Day 199, selecting COMIDA2 results # 6 of 9 For Julian Day 200, selecting COMIDA2 results # 6 of 9 For Julian Day 200, selecting COMIDA2 results # 6 of 9 For Julian Day 200, selecting COMIDA2 results # 6 of 9 For Julian Day 203, selecting COMIDA2 results # 6 of 9 For Julian Day 206, selecting COMIDA2 results # 6 of 9 For Julian Day 206, selecting COMIDA2 results # 6 of 9 For Julian Day 208, selecting COMIDA2 results # 6 of 9 For Julian Day 212, selecting COMIDA2 results # 6 of 9 For Julian Day 212, selecting COMIDA2 results # 6 of 9 For Julian Day 212, selecting COMIDA2 results # 6 of 9 For Julian Day 213, selecting COMIDA2 results # 6 of 9 For Julian Day 216, selecting COMIDA2 results # 6 of 9 For Julian Day 216, selecting COMIDA2 results # 6 of 9 For Julian Day 218, selecting COMIDA2 results # 6 of 9 For Julian Day 219, selecting COMIDA2 results # 6 of 9 For Julian Day 219, selecting COMIDA2 results # 6 of 9 For Julian Day 219, selecting COMIDA2 results # 6 of 9 For Julian Day 228, selecting COMIDA2 results # 7 of 9 For Julian Day 228, selecting COMIDA2 results # 7 of 9
Calculation IP-CALC-09-00265, Rev. 0, Att. A.1, Page 71 For Julian Day 228, selecting COMIDA2 results # 7 of 9 For Julian Day 229, selecting COMIDA2 results # 7 of 9 For Julian Day 229, selecting COMIDA2 results # 7 of 9 For Julian Day 229, selecting COMIDA2 results # 7 of 9 For Julian Day 245, selecting COMIDA2 results # 7 of 9 For Julian Day 246, selecting COMIDA2 results # 7 of 9 For Julian Day 250, selecting COMIDA2 results # 7 of 9 For Julian Day 251, selecting COMIDA2 results # 7 of 9 For Julian Day 256, selecting COMIDA2 results # 7 of 9 For Julian Day 257, selecting COMIDA2 results # 8 of 9 For Julian Day 258, selecting COMIDA2 results # 8 of 9 For Julian Day 258, selecting COMIDA2 results # 8 of 9 For Julian Day 258, selecting COMIDA2 results # 8 of 9 For Julian Day 258, selecting COMIDA2 results # 8 of 9 For Julian Day 259, selecting COMIDA2 results # 8 of 9 For Julian Day 260, selecting COMIDA2 results # 8 of 9 For Julian Day 263, selecting COMIDA2 results # 8 of 9 For Julian Day 263, selecting COMIDA2 results # 8 of 9 For Julian Day 263, selecting COMIDA2 results # 8 of 9 For Julian Day 264, selecting COMIDA2 results # 8 of 9 For Julian Day 271, selecting COMIDA2 results # 8 of 9 For Julian Day 272, selecting COMIDA2 results # 8 of 9 For Julian Day 273, selecting COMIDA2 results # 8 of 9 For Julian Day 276, selecting COMIDA2 results # 8 of 9 For Julian Day 282, selecting COMIDA2 results # 8 of 9 For Julian Day 284, selecting COMIDA2 results # 8 of 9 For Julian Day 288, selecting COMIDA2 results # 9 of 9 For Julian Day 295, selecting COMIDA2 results # 9 of 9 For Julian Day 299, selecting COMIDA2 results # 9 of 9 For Julian Day 301, selecting COMIDA2 results # 9 of 9 For Julian Day 302, selecting COMIDA2 results # 9 of 9 For Julian Day 311, selecting COMIDA2 results # 9 of 9 For Julian Day 314, selecting COMIDA2 results # 9 of 9 For Julian Day 314, selecting COMIDA2 results # 9 of 9 For Julian Day 314, selecting COMIDA2 results # 9 of 9 For Julian Day 315, selecting COMIDA2 results # 9 of 9 For Julian Day 319, selecting COMIDA2 results # 9 of 9 For Julian Day 319, selecting COMIDA2 results # 9 of 9 For Julian Day 331, selecting COMIDA2 results # 9 of 9 For Julian Day 334, selecting COMIDA2 results # 1 of 9 For Julian Day 339, selecting COMIDA2 results # 1 of 9 For Julian Day 347, selecting COMIDA2 results # 1 of 9 For Julian Day 349, selecting COMIDA2 results # 1 of 9 For Julian Day 352, selecting COMIDA2 results # 1 of 9 For Julian Day 363, selecting COMIDA2 results # 1 of 9 For Julian Day 364, selecting COMIDA2 results # 1 of 9 For Julian Day 365, selecting COMIDA2 results # 1 of 9 For Julian Day 4, selecting COMIDA2 results # 1 of 9 For Julian Day 9, selecting COMIDA2 results # 1 of 9 For Julian Day 10, selecting COMIDA2 results # 1 of 9 For Julian Day 10, selecting COMIDA2 results # 1 of 9 For Julian Day 10, selecting COMIDA2 results # 1 of 9 For Julian Day 10, selecting COMIDA2 results # 1 of 9 For Julian Day 11, selecting COMIDA2 results # 1 of 9 For Julian Day 13, selecting COMIDA2 results # 1 of 9 For Julian Day 14, selecting COMIDA2 results # 1 of 9 For Julian Day 16, selecting COMIDA2 results # 1 of 9 For Julian Day 22, selecting COMIDA2 results # 1 of 9 For Julian Day 25, selecting COMIDA2 results # 1 of 9
Calculation IP-CALC-09-00265, Rev. 0, Att. A.1, Page 72 For Julian Day 30, selecting COMIDA2 results # 1 of 9 For Julian Day 38, selecting COMIDA2 results # 2 of 9 For Julian Day 40, selecting COMIDA2 results # 2 of 9 For Julian Day 41, selecting COMIDA2 results # 2 of 9 For Julian Day 44, selecting COMIDA2 results # 2 of 9 For Julian Day 45, selecting COMIDA2 results # 2 of 9 For Julian Day 49, selecting COMIDA2 results # 2 of 9 For Julian Day 49, selecting COMIDA2 results # 2 of 9 For Julian Day 49, selecting COMIDA2 results # 2 of 9 For Julian Day 55, selecting COMIDA2 results # 2 of 9 For Julian Day 56, selecting COMIDA2 results # 2 of 9 For Julian Day 56, selecting COMIDA2 results # 2 of 9 For Julian Day 58, selecting COMIDA2 results # 2 of 9 For Julian Day 58, selecting COMIDA2 results # 2 of 9 For Julian Day 59, selecting COMIDA2 results # 2 of 9 For Julian Day 71, selecting COMIDA2 results # 2 of 9 For Julian Day 78, selecting COMIDA2 results # 2 of 9 For Julian Day 78, selecting COMIDA2 results # 2 of 9 For Julian Day 86, selecting COMIDA2 results # 2 of 9 For Julian Day 88, selecting COMIDA2 results # 2 of 9 For Julian Day 95, selecting COMIDA2 results # 3 of 9 For Julian Day 95, selecting COMIDA2 results # 3 of 9 For Julian Day 95, selecting COMIDA2 results # 3 of 9 For Julian Day 97, selecting COMIDA2 results # 3 of 9 For Julian Day 97, selecting COMIDA2 results # 3 of 9 For Julian Day 97, selecting COMIDA2 results # 3 of 9 For Julian Day 99, selecting COMIDA2 results # 3 of 9 For Julian Day 100, selecting COMIDA2 results # 3 of 9 For Julian Day 105, selecting COMIDA2 results # 3 of 9 For Julian Day 112, selecting COMIDA2 results # 3 of 9 For Julian Day 120, selecting COMIDA2 results # 3 of 9 For Julian Day 124, selecting COMIDA2 results # 3 of 9 For Julian Day 125, selecting COMIDA2 results # 3 of 9 For Julian Day 127, selecting COMIDA2 results # 3 of 9 For Julian Day 129, selecting COMIDA2 results # 3 of 9 For Julian Day 129, selecting COMIDA2 results # 3 of 9 For Julian Day 129, selecting COMIDA2 results # 3 of 9 For Julian Day 131, selecting COMIDA2 results # 3 of 9 For Julian Day 132, selecting COMIDA2 results # 3 of 9 For Julian Day 134, selecting COMIDA2 results # 3 of 9 For Julian Day 137, selecting COMIDA2 results # 4 of 9 For Julian Day 138, selecting COMIDA2 results # 4 of 9 For Julian Day 141, selecting COMIDA2 results # 4 of 9 For Julian Day 145, selecting COMIDA2 results # 4 of 9 For Julian Day 151, selecting COMIDA2 results # 4 of 9
Calculation IP-CALC-09-00265, Rev. 0, Att. A.1, Page 73 WARNING!! WARNING!! WARNING!! WARNING!!
THE TOTAL RELEASE DURATION EXCEEDS 20 HOURS.
THIS MAY CAUSE ERRONEOUS RESULTS TO BE PRODUCED.
WARNING!! WARNING!! WARNING!! WARNING!!
Calculation IP-CALC-09-00265, Rev. 0, Att. A.1, Page 74 WARNING!! WARNING!! WARNING!! WARNING!!
A 10 HOUR RELEASE DURATION IS BEING USED BY ATMOS FOR CALCULATING THE EXPANSION FACTOR OF PLUME # 1 INSTEAD OF THE USER-SUPPLIED 24.00 HOURS WARNING!! WARNING!! WARNING!! WARNING!!
For Julian Day 152, selecting COMIDA2 results # 4 of 9 For Julian Day 156, selecting COMIDA2 results # 4 of 9 For Julian Day 156, selecting COMIDA2 results # 4 of 9 For Julian Day 158, selecting COMIDA2 results # 4 of 9 For Julian Day 158, selecting COMIDA2 results # 4 of 9 For Julian Day 163, selecting COMIDA2 results # 4 of 9 For Julian Day 163, selecting COMIDA2 results # 4 of 9 For Julian Day 163, selecting COMIDA2 results # 4 of 9 For Julian Day 163, selecting COMIDA2 results # 4 of 9 For Julian Day 164, selecting COMIDA2 results # 4 of 9 For Julian Day 165, selecting COMIDA2 results # 4 of 9 For Julian Day 165, selecting COMIDA2 results # 4 of 9 For Julian Day 165, selecting COMIDA2 results # 4 of 9 For Julian Day 166, selecting COMIDA2 results # 4 of 9 For Julian Day 166, selecting COMIDA2 results # 4 of 9 For Julian Day 169, selecting COMIDA2 results # 5 of 9 For Julian Day 170, selecting COMIDA2 results # 5 of 9 For Julian Day 179, selecting COMIDA2 results # 5 of 9 For Julian Day 179, selecting COMIDA2 results # 5 of 9 For Julian Day 179, selecting COMIDA2 results # 5 of 9 For Julian Day 179, selecting COMIDA2 results # 5 of 9 For Julian Day 180, selecting COMIDA2 results # 5 of 9 For Julian Day 180, selecting COMIDA2 results # 5 of 9 For Julian Day 184, selecting COMIDA2 results # 5 of 9 For Julian Day 193, selecting COMIDA2 results # 6 of 9 For Julian Day 196, selecting COMIDA2 results # 6 of 9 For Julian Day 196, selecting COMIDA2 results # 6 of 9 For Julian Day 197, selecting COMIDA2 results # 6 of 9 For Julian Day 197, selecting COMIDA2 results # 6 of 9 For Julian Day 197, selecting COMIDA2 results # 6 of 9 For Julian Day 197, selecting COMIDA2 results # 6 of 9 For Julian Day 199, selecting COMIDA2 results # 6 of 9 For Julian Day 200, selecting COMIDA2 results # 6 of 9 For Julian Day 200, selecting COMIDA2 results # 6 of 9 For Julian Day 200, selecting COMIDA2 results # 6 of 9 For Julian Day 203, selecting COMIDA2 results # 6 of 9 For Julian Day 206, selecting COMIDA2 results # 6 of 9 For Julian Day 206, selecting COMIDA2 results # 6 of 9 For Julian Day 208, selecting COMIDA2 results # 6 of 9 For Julian Day 212, selecting COMIDA2 results # 6 of 9 For Julian Day 212, selecting COMIDA2 results # 6 of 9 For Julian Day 212, selecting COMIDA2 results # 6 of 9 For Julian Day 213, selecting COMIDA2 results # 6 of 9 For Julian Day 216, selecting COMIDA2 results # 6 of 9 For Julian Day 216, selecting COMIDA2 results # 6 of 9 For Julian Day 218, selecting COMIDA2 results # 6 of 9 For Julian Day 219, selecting COMIDA2 results # 6 of 9 For Julian Day 219, selecting COMIDA2 results # 6 of 9 For Julian Day 219, selecting COMIDA2 results # 6 of 9 For Julian Day 228, selecting COMIDA2 results # 7 of 9 For Julian Day 228, selecting COMIDA2 results # 7 of 9
Calculation IP-CALC-09-00265, Rev. 0, Att. A.1, Page 75 For Julian Day 228, selecting COMIDA2 results # 7 of 9 For Julian Day 229, selecting COMIDA2 results # 7 of 9 For Julian Day 229, selecting COMIDA2 results # 7 of 9 For Julian Day 229, selecting COMIDA2 results # 7 of 9 For Julian Day 245, selecting COMIDA2 results # 7 of 9 For Julian Day 246, selecting COMIDA2 results # 7 of 9 For Julian Day 250, selecting COMIDA2 results # 7 of 9 For Julian Day 251, selecting COMIDA2 results # 7 of 9 For Julian Day 256, selecting COMIDA2 results # 7 of 9 For Julian Day 257, selecting COMIDA2 results # 8 of 9 For Julian Day 258, selecting COMIDA2 results # 8 of 9 For Julian Day 258, selecting COMIDA2 results # 8 of 9 For Julian Day 258, selecting COMIDA2 results # 8 of 9 For Julian Day 258, selecting COMIDA2 results # 8 of 9 For Julian Day 259, selecting COMIDA2 results # 8 of 9 For Julian Day 260, selecting COMIDA2 results # 8 of 9 For Julian Day 263, selecting COMIDA2 results # 8 of 9 For Julian Day 263, selecting COMIDA2 results # 8 of 9 For Julian Day 263, selecting COMIDA2 results # 8 of 9 For Julian Day 264, selecting COMIDA2 results # 8 of 9 For Julian Day 271, selecting COMIDA2 results # 8 of 9 For Julian Day 272, selecting COMIDA2 results # 8 of 9 For Julian Day 273, selecting COMIDA2 results # 8 of 9 For Julian Day 276, selecting COMIDA2 results # 8 of 9 For Julian Day 282, selecting COMIDA2 results # 8 of 9 For Julian Day 284, selecting COMIDA2 results # 8 of 9 For Julian Day 288, selecting COMIDA2 results # 9 of 9 For Julian Day 295, selecting COMIDA2 results # 9 of 9 For Julian Day 299, selecting COMIDA2 results # 9 of 9 For Julian Day 301, selecting COMIDA2 results # 9 of 9 For Julian Day 302, selecting COMIDA2 results # 9 of 9 For Julian Day 311, selecting COMIDA2 results # 9 of 9 For Julian Day 314, selecting COMIDA2 results # 9 of 9 For Julian Day 314, selecting COMIDA2 results # 9 of 9 For Julian Day 314, selecting COMIDA2 results # 9 of 9 For Julian Day 315, selecting COMIDA2 results # 9 of 9 For Julian Day 319, selecting COMIDA2 results # 9 of 9 For Julian Day 319, selecting COMIDA2 results # 9 of 9 For Julian Day 331, selecting COMIDA2 results # 9 of 9 For Julian Day 334, selecting COMIDA2 results # 1 of 9 For Julian Day 339, selecting COMIDA2 results # 1 of 9 For Julian Day 347, selecting COMIDA2 results # 1 of 9 For Julian Day 349, selecting COMIDA2 results # 1 of 9 For Julian Day 352, selecting COMIDA2 results # 1 of 9 For Julian Day 363, selecting COMIDA2 results # 1 of 9 For Julian Day 364, selecting COMIDA2 results # 1 of 9 For Julian Day 365, selecting COMIDA2 results # 1 of 9 For Julian Day 4, selecting COMIDA2 results # 1 of 9 For Julian Day 9, selecting COMIDA2 results # 1 of 9 For Julian Day 10, selecting COMIDA2 results # 1 of 9 For Julian Day 10, selecting COMIDA2 results # 1 of 9 For Julian Day 10, selecting COMIDA2 results # 1 of 9 For Julian Day 10, selecting COMIDA2 results # 1 of 9 For Julian Day 11, selecting COMIDA2 results # 1 of 9 For Julian Day 13, selecting COMIDA2 results # 1 of 9 For Julian Day 14, selecting COMIDA2 results # 1 of 9 For Julian Day 16, selecting COMIDA2 results # 1 of 9 For Julian Day 22, selecting COMIDA2 results # 1 of 9 For Julian Day 25, selecting COMIDA2 results # 1 of 9
Calculation IP-CALC-09-00265, Rev. 0, Att. A.1, Page 76 For Julian Day 30, selecting COMIDA2 results # 1 of 9 For Julian Day 38, selecting COMIDA2 results # 2 of 9 For Julian Day 40, selecting COMIDA2 results # 2 of 9 For Julian Day 41, selecting COMIDA2 results # 2 of 9 For Julian Day 44, selecting COMIDA2 results # 2 of 9 For Julian Day 45, selecting COMIDA2 results # 2 of 9 For Julian Day 49, selecting COMIDA2 results # 2 of 9 For Julian Day 49, selecting COMIDA2 results # 2 of 9 For Julian Day 49, selecting COMIDA2 results # 2 of 9 For Julian Day 55, selecting COMIDA2 results # 2 of 9 For Julian Day 56, selecting COMIDA2 results # 2 of 9 For Julian Day 56, selecting COMIDA2 results # 2 of 9 For Julian Day 58, selecting COMIDA2 results # 2 of 9 For Julian Day 58, selecting COMIDA2 results # 2 of 9 For Julian Day 59, selecting COMIDA2 results # 2 of 9 For Julian Day 71, selecting COMIDA2 results # 2 of 9 For Julian Day 78, selecting COMIDA2 results # 2 of 9 For Julian Day 78, selecting COMIDA2 results # 2 of 9 For Julian Day 86, selecting COMIDA2 results # 2 of 9 For Julian Day 88, selecting COMIDA2 results # 2 of 9 For Julian Day 95, selecting COMIDA2 results # 3 of 9 For Julian Day 95, selecting COMIDA2 results # 3 of 9 For Julian Day 95, selecting COMIDA2 results # 3 of 9 For Julian Day 97, selecting COMIDA2 results # 3 of 9 For Julian Day 97, selecting COMIDA2 results # 3 of 9 For Julian Day 97, selecting COMIDA2 results # 3 of 9 For Julian Day 99, selecting COMIDA2 results # 3 of 9 For Julian Day 100, selecting COMIDA2 results # 3 of 9 For Julian Day 105, selecting COMIDA2 results # 3 of 9 For Julian Day 112, selecting COMIDA2 results # 3 of 9 For Julian Day 120, selecting COMIDA2 results # 3 of 9 For Julian Day 124, selecting COMIDA2 results # 3 of 9 For Julian Day 125, selecting COMIDA2 results # 3 of 9 For Julian Day 127, selecting COMIDA2 results # 3 of 9 For Julian Day 129, selecting COMIDA2 results # 3 of 9 For Julian Day 129, selecting COMIDA2 results # 3 of 9 For Julian Day 129, selecting COMIDA2 results # 3 of 9 For Julian Day 131, selecting COMIDA2 results # 3 of 9 For Julian Day 132, selecting COMIDA2 results # 3 of 9 For Julian Day 134, selecting COMIDA2 results # 3 of 9 For Julian Day 137, selecting COMIDA2 results # 4 of 9 For Julian Day 138, selecting COMIDA2 results # 4 of 9 For Julian Day 141, selecting COMIDA2 results # 4 of 9 For Julian Day 145, selecting COMIDA2 results # 4 of 9 For Julian Day 151, selecting COMIDA2 results # 4 of 9
Calculation IP-CALC-09-00265, Rev. 0, Att. A.1, Page 77 WARNING!! WARNING!! WARNING!! WARNING!!
THE TOTAL RELEASE DURATION EXCEEDS 20 HOURS.
THIS MAY CAUSE ERRONEOUS RESULTS TO BE PRODUCED.
WARNING!! WARNING!! WARNING!! WARNING!!
Calculation IP-CALC-09-00265, Rev. 0, Att. A.1, Page 78 WARNING!! WARNING!! WARNING!! WARNING!!
A 10 HOUR RELEASE DURATION IS BEING USED BY ATMOS FOR CALCULATING THE EXPANSION FACTOR OF PLUME # 1 INSTEAD OF THE USER-SUPPLIED 24.00 HOURS WARNING!! WARNING!! WARNING!! WARNING!!
For Julian Day 152, selecting COMIDA2 results # 4 of 9 For Julian Day 156, selecting COMIDA2 results # 4 of 9 For Julian Day 156, selecting COMIDA2 results # 4 of 9 For Julian Day 158, selecting COMIDA2 results # 4 of 9 For Julian Day 158, selecting COMIDA2 results # 4 of 9 For Julian Day 163, selecting COMIDA2 results # 4 of 9 For Julian Day 163, selecting COMIDA2 results # 4 of 9 For Julian Day 163, selecting COMIDA2 results # 4 of 9 For Julian Day 163, selecting COMIDA2 results # 4 of 9 For Julian Day 164, selecting COMIDA2 results # 4 of 9 For Julian Day 165, selecting COMIDA2 results # 4 of 9 For Julian Day 165, selecting COMIDA2 results # 4 of 9 For Julian Day 165, selecting COMIDA2 results # 4 of 9 For Julian Day 166, selecting COMIDA2 results # 4 of 9 For Julian Day 166, selecting COMIDA2 results # 4 of 9 For Julian Day 169, selecting COMIDA2 results # 5 of 9 For Julian Day 170, selecting COMIDA2 results # 5 of 9 For Julian Day 179, selecting COMIDA2 results # 5 of 9 For Julian Day 179, selecting COMIDA2 results # 5 of 9 For Julian Day 179, selecting COMIDA2 results # 5 of 9 For Julian Day 179, selecting COMIDA2 results # 5 of 9 For Julian Day 180, selecting COMIDA2 results # 5 of 9 For Julian Day 180, selecting COMIDA2 results # 5 of 9 For Julian Day 184, selecting COMIDA2 results # 5 of 9 For Julian Day 193, selecting COMIDA2 results # 6 of 9 For Julian Day 196, selecting COMIDA2 results # 6 of 9 For Julian Day 196, selecting COMIDA2 results # 6 of 9 For Julian Day 197, selecting COMIDA2 results # 6 of 9 For Julian Day 197, selecting COMIDA2 results # 6 of 9 For Julian Day 197, selecting COMIDA2 results # 6 of 9 For Julian Day 197, selecting COMIDA2 results # 6 of 9 For Julian Day 199, selecting COMIDA2 results # 6 of 9 For Julian Day 200, selecting COMIDA2 results # 6 of 9 For Julian Day 200, selecting COMIDA2 results # 6 of 9 For Julian Day 200, selecting COMIDA2 results # 6 of 9 For Julian Day 203, selecting COMIDA2 results # 6 of 9 For Julian Day 206, selecting COMIDA2 results # 6 of 9 For Julian Day 206, selecting COMIDA2 results # 6 of 9 For Julian Day 208, selecting COMIDA2 results # 6 of 9 For Julian Day 212, selecting COMIDA2 results # 6 of 9 For Julian Day 212, selecting COMIDA2 results # 6 of 9 For Julian Day 212, selecting COMIDA2 results # 6 of 9 For Julian Day 213, selecting COMIDA2 results # 6 of 9 For Julian Day 216, selecting COMIDA2 results # 6 of 9 For Julian Day 216, selecting COMIDA2 results # 6 of 9 For Julian Day 218, selecting COMIDA2 results # 6 of 9 For Julian Day 219, selecting COMIDA2 results # 6 of 9 For Julian Day 219, selecting COMIDA2 results # 6 of 9 For Julian Day 219, selecting COMIDA2 results # 6 of 9 For Julian Day 228, selecting COMIDA2 results # 7 of 9 For Julian Day 228, selecting COMIDA2 results # 7 of 9
Calculation IP-CALC-09-00265, Rev. 0, Att. A.1, Page 79 For Julian Day 228, selecting COMIDA2 results # 7 of 9 For Julian Day 229, selecting COMIDA2 results # 7 of 9 For Julian Day 229, selecting COMIDA2 results # 7 of 9 For Julian Day 229, selecting COMIDA2 results # 7 of 9 For Julian Day 245, selecting COMIDA2 results # 7 of 9 For Julian Day 246, selecting COMIDA2 results # 7 of 9 For Julian Day 250, selecting COMIDA2 results # 7 of 9 For Julian Day 251, selecting COMIDA2 results # 7 of 9 For Julian Day 256, selecting COMIDA2 results # 7 of 9 For Julian Day 257, selecting COMIDA2 results # 8 of 9 For Julian Day 258, selecting COMIDA2 results # 8 of 9 For Julian Day 258, selecting COMIDA2 results # 8 of 9 For Julian Day 258, selecting COMIDA2 results # 8 of 9 For Julian Day 258, selecting COMIDA2 results # 8 of 9 For Julian Day 259, selecting COMIDA2 results # 8 of 9 For Julian Day 260, selecting COMIDA2 results # 8 of 9 For Julian Day 263, selecting COMIDA2 results # 8 of 9 For Julian Day 263, selecting COMIDA2 results # 8 of 9 For Julian Day 263, selecting COMIDA2 results # 8 of 9 For Julian Day 264, selecting COMIDA2 results # 8 of 9 For Julian Day 271, selecting COMIDA2 results # 8 of 9 For Julian Day 272, selecting COMIDA2 results # 8 of 9 For Julian Day 273, selecting COMIDA2 results # 8 of 9 For Julian Day 276, selecting COMIDA2 results # 8 of 9 For Julian Day 282, selecting COMIDA2 results # 8 of 9 For Julian Day 284, selecting COMIDA2 results # 8 of 9 For Julian Day 288, selecting COMIDA2 results # 9 of 9 For Julian Day 295, selecting COMIDA2 results # 9 of 9 For Julian Day 299, selecting COMIDA2 results # 9 of 9 For Julian Day 301, selecting COMIDA2 results # 9 of 9 For Julian Day 302, selecting COMIDA2 results # 9 of 9 For Julian Day 311, selecting COMIDA2 results # 9 of 9 For Julian Day 314, selecting COMIDA2 results # 9 of 9 For Julian Day 314, selecting COMIDA2 results # 9 of 9 For Julian Day 314, selecting COMIDA2 results # 9 of 9 For Julian Day 315, selecting COMIDA2 results # 9 of 9 For Julian Day 319, selecting COMIDA2 results # 9 of 9 For Julian Day 319, selecting COMIDA2 results # 9 of 9 For Julian Day 331, selecting COMIDA2 results # 9 of 9 For Julian Day 334, selecting COMIDA2 results # 1 of 9 For Julian Day 339, selecting COMIDA2 results # 1 of 9 For Julian Day 347, selecting COMIDA2 results # 1 of 9 For Julian Day 349, selecting COMIDA2 results # 1 of 9 For Julian Day 352, selecting COMIDA2 results # 1 of 9 For Julian Day 363, selecting COMIDA2 results # 1 of 9 For Julian Day 364, selecting COMIDA2 results # 1 of 9 For Julian Day 365, selecting COMIDA2 results # 1 of 9 For Julian Day 4, selecting COMIDA2 results # 1 of 9 For Julian Day 9, selecting COMIDA2 results # 1 of 9 For Julian Day 10, selecting COMIDA2 results # 1 of 9 For Julian Day 10, selecting COMIDA2 results # 1 of 9 For Julian Day 10, selecting COMIDA2 results # 1 of 9 For Julian Day 10, selecting COMIDA2 results # 1 of 9 For Julian Day 11, selecting COMIDA2 results # 1 of 9 For Julian Day 13, selecting COMIDA2 results # 1 of 9 For Julian Day 14, selecting COMIDA2 results # 1 of 9 For Julian Day 16, selecting COMIDA2 results # 1 of 9 For Julian Day 22, selecting COMIDA2 results # 1 of 9 For Julian Day 25, selecting COMIDA2 results # 1 of 9
Calculation IP-CALC-09-00265, Rev. 0, Att. A.1, Page 80 For Julian Day 30, selecting COMIDA2 results # 1 of 9 For Julian Day 38, selecting COMIDA2 results # 2 of 9 For Julian Day 40, selecting COMIDA2 results # 2 of 9 For Julian Day 41, selecting COMIDA2 results # 2 of 9 For Julian Day 44, selecting COMIDA2 results # 2 of 9 For Julian Day 45, selecting COMIDA2 results # 2 of 9 For Julian Day 49, selecting COMIDA2 results # 2 of 9 For Julian Day 49, selecting COMIDA2 results # 2 of 9 For Julian Day 49, selecting COMIDA2 results # 2 of 9 For Julian Day 55, selecting COMIDA2 results # 2 of 9 For Julian Day 56, selecting COMIDA2 results # 2 of 9 For Julian Day 56, selecting COMIDA2 results # 2 of 9 For Julian Day 58, selecting COMIDA2 results # 2 of 9 For Julian Day 58, selecting COMIDA2 results # 2 of 9 For Julian Day 59, selecting COMIDA2 results # 2 of 9 For Julian Day 71, selecting COMIDA2 results # 2 of 9 For Julian Day 78, selecting COMIDA2 results # 2 of 9 For Julian Day 78, selecting COMIDA2 results # 2 of 9 For Julian Day 86, selecting COMIDA2 results # 2 of 9 For Julian Day 88, selecting COMIDA2 results # 2 of 9 For Julian Day 95, selecting COMIDA2 results # 3 of 9 For Julian Day 95, selecting COMIDA2 results # 3 of 9 For Julian Day 95, selecting COMIDA2 results # 3 of 9 For Julian Day 97, selecting COMIDA2 results # 3 of 9 For Julian Day 97, selecting COMIDA2 results # 3 of 9 For Julian Day 97, selecting COMIDA2 results # 3 of 9 For Julian Day 99, selecting COMIDA2 results # 3 of 9 For Julian Day 100, selecting COMIDA2 results # 3 of 9 For Julian Day 105, selecting COMIDA2 results # 3 of 9 For Julian Day 112, selecting COMIDA2 results # 3 of 9 For Julian Day 120, selecting COMIDA2 results # 3 of 9 For Julian Day 124, selecting COMIDA2 results # 3 of 9 For Julian Day 125, selecting COMIDA2 results # 3 of 9 For Julian Day 127, selecting COMIDA2 results # 3 of 9 For Julian Day 129, selecting COMIDA2 results # 3 of 9 For Julian Day 129, selecting COMIDA2 results # 3 of 9 For Julian Day 129, selecting COMIDA2 results # 3 of 9 For Julian Day 131, selecting COMIDA2 results # 3 of 9 For Julian Day 132, selecting COMIDA2 results # 3 of 9 For Julian Day 134, selecting COMIDA2 results # 3 of 9 For Julian Day 137, selecting COMIDA2 results # 4 of 9 For Julian Day 138, selecting COMIDA2 results # 4 of 9 For Julian Day 141, selecting COMIDA2 results # 4 of 9 For Julian Day 145, selecting COMIDA2 results # 4 of 9 For Julian Day 151, selecting COMIDA2 results # 4 of 9
Calculation IP-CALC-09-00265, Rev. 0, Att. A.1, Page 81 DATE AND TIME OF RUN = MACCS2 11-NOV-09 19:34:05 VERSION 1.13.1: last revised 1/8/04, K. McFadden "ATMOS" DESCRIPTION = ATMOS INPUT FOR IPEC CALCULATIONS "EARLY" DESCRIPTION = EARLY.IN, IPEC INPUT FROM THE EVACUATION TIME ESTIMATES "CHRONC" DESCRIPTION = CHRONC.IN - IPEC, "New" COMIDA2-Based Food Model SOURCE TERM 1 OF 8:
NCF OVERALL RESULTS OBTAINED BY COMBINING 1 EMERGENCY RESPONSE COHORTS FROM "EARLY" WITH THE WEIGHTING FRACTIONS BELOW APPLIED TO THEM:
FRACTION OF THE PEOPLE COHORT 1 = NO EVACUATION, RELOCATION MODELS APPLY EVERYWHE 1.000 AND THEN MERGING THE 1 RESULTS ABOVE WITH THE SINGLE SET OF RESULTS FROM "CHRONC" DESCRIBED BELOW:
COHORT 2 = CHRONC.IN - IPEC, "New" COMIDA2-Based Food Model RESULTS WHICH ARE PRODUCED ONLY BY "EARLY" OR ONLY BY "CHRONC" ARE PRESENTED IN LATER SECTIONS.
11-NOV-09 19:34:05 PAGE 1 PROB QUANTILES PEAK PEAK PEAK NON-ZERO MEAN 50TH 90TH 95TH 99TH 99.5TH CONS PROB TRIAL HEALTH EFFECTS CASES CAN FAT/TOTAL 0-80.5 km 1.0000 2.12E+00 2.01E+00 3.75E+00 4.76E+00 7.30E+00 7.82E+00 9.18E+00 1.00E-03 98 CAN FAT/TOTAL 0-16.1 km 1.0000 8.47E-01 8.00E-01 1.36E+00 1.61E+00 2.04E+00 2.09E+00 2.68E+00 1.24E-06 147 POPULATION DOSE (Sv)
L-EDEWBODY TOT LIF 0-80.5 km 1.0000 4.75E+01 4.28E+01 9.54E+01 1.12E+02 1.51E+02 1.72E+02 2.05E+02 1.00E-03 98 POPULATION WEIGHTED RISK CAN FAT/TOTAL 0-16.1 km 1.0000 2.15E-06 2.03E-06 3.58E-06 4.16E-06 5.12E-06 5.24E-06 6.82E-06 1.24E-06 147
Calculation IP-CALC-09-00265, Rev. 0, Att. A.1, Page 82 DATE AND TIME OF RUN = MACCS2 11-NOV-09 19:34:05 VERSION 1.13.1: last revised 1/8/04, K. McFadden "ATMOS" DESCRIPTION = ATMOS INPUT FOR IPEC CALCULATIONS "EARLY" DESCRIPTION = EARLY.IN, IPEC INPUT FROM THE EVACUATION TIME ESTIMATES SOURCE TERM 1 OF 8:
NCF RESULTS FOR A SINGLE EMERGENCY RESPONSE COHORT WITHOUT ANY WEIGHTING FRACTIONS BEING APPLIED COHORT 1 = NO EVACUATION, RELOCATION MODELS APPLY EVERYWHE 11-NOV-09 19:34:05 PAGE 2 PROB QUANTILES PEAK PEAK PEAK NON-ZERO MEAN 50TH 90TH 95TH 99TH 99.5TH CONS PROB TRIAL HEALTH EFFECTS CASES ERL FAT/TOTAL 0-80.5 km 0.0000 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0 CAN FAT/TOTAL 0-80.5 km 1.0000 1.53E-01 1.20E-01 2.94E-01 3.30E-01 4.21E-01 4.67E-01 5.98E-01 1.00E-03 98 CAN FAT/TOTAL 0-16.1 km 1.0000 6.41E-02 5.93E-02 1.04E-01 1.09E-01 1.22E-01 1.27E-01 2.02E-01 1.24E-06 147 ERL FAT/TOTAL 0-16.1 km 0.0000 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0 AVERAGE INDIVIDUAL RISK ERL FAT/TOTAL 0-0.3 km 0.0000 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0 ERL FAT/TOTAL 0.3-1.6 km 0.0000 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0 ERL FAT/TOTAL 1.6-3.2 km 0.0000 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0 POPULATION DOSE (Sv)
L-EDEWBODY TOT LIF 0-80.5 km 1.0000 3.34E+00 3.08E+00 6.50E+00 7.74E+00 1.02E+01 1.10E+01 1.31E+01 1.00E-03 98 POPULATION WEIGHTED RISK ERL FAT/TOTAL 0-3.2 km 0.0000 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0 CAN FAT/TOTAL 0-16.1 km 1.0000 1.64E-07 1.40E-07 3.02E-07 3.22E-07 3.72E-07 3.95E-07 5.17E-07 1.24E-06 147
Calculation IP-CALC-09-00265, Rev. 0, Att. A.1, Page 83 DATE AND TIME OF RUN = MACCS2 11-NOV-09 19:34:05 VERSION 1.13.1: last revised 1/8/04, K. McFadden "ATMOS" DESCRIPTION = ATMOS INPUT FOR IPEC CALCULATIONS "EARLY" DESCRIPTION = EARLY.IN, IPEC INPUT FROM THE EVACUATION TIME ESTIMATES "CHRONC" DESCRIPTION = CHRONC.IN - IPEC, "New" COMIDA2-Based Food Model SOURCE TERM 1 OF 8:
NCF RESULTS FROM THE "CHRONC" MODULE ALONE COHORT 2 = CHRONC.IN - IPEC, "New" COMIDA2-Based Food Model 11-NOV-09 19:34:05 PAGE 3 PROB QUANTILES PEAK PEAK PEAK NON-ZERO MEAN 50TH 90TH 95TH 99TH 99.5TH CONS PROB TRIAL HEALTH EFFECTS CASES CAN FAT/TOTAL 0-80.5 km 1.0000 1.97E+00 1.75E+00 3.57E+00 4.52E+00 6.14E+00 6.84E+00 8.58E+00 1.00E-03 98 CAN FAT/TOTAL 0-16.1 km 1.0000 7.83E-01 7.44E-01 1.27E+00 1.48E+00 2.01E+00 2.04E+00 2.48E+00 1.24E-06 147 POPULATION DOSE (Sv)
L-EDEWBODY TOT LIF 0-80.5 km 1.0000 4.41E+01 3.75E+01 7.89E+01 9.98E+01 1.31E+02 1.47E+02 1.92E+02 1.00E-03 98 POPULATION WEIGHTED RISK CAN FAT/TOTAL 0-16.1 km 1.0000 1.98E-06 1.76E-06 3.40E-06 3.87E-06 5.03E-06 5.12E-06 6.30E-06 1.24E-06 147 L-EDEWBODY POP. DOSE (Sv) 0-80.5 km TOTAL LONG-TERM PATHWAYS DOSE 1.0000 4.41E+01 3.75E+01 7.89E+01 9.98E+01 1.31E+02 1.47E+02 1.92E+02 1.00E-03 98 LONG-TERM DIRECT EXPOSURE PATHWAYS 1.0000 4.36E+01 3.68E+01 7.89E+01 9.98E+01 1.31E+02 1.47E+02 1.92E+02 1.00E-03 98 TOTAL INGESTION PATHWAYS DOSE 1.0000 5.17E-01 1.87E-01 1.53E+00 2.05E+00 2.38E+00 2.54E+00 3.97E+00 4.53E-05 62 LONG-TERM GROUNDSHINE DOSE 1.0000 4.23E+01 3.44E+01 7.83E+01 9.91E+01 1.29E+02 1.44E+02 1.86E+02 1.00E-03 98 LONG-TERM RESUSPENSION DOSE 1.0000 1.32E+00 1.08E+00 2.38E+00 3.01E+00 4.11E+00 4.70E+00 5.80E+00 1.00E-03 98 WATER INGESTION DOSE 1.0000 2.40E-02 2.14E-02 4.15E-02 5.00E-02 5.37E-02 5.54E-02 7.32E-02 1.04E-05 146 POP.-DEPENDENT DECONTAMINATION DOSE 0.2966 3.51E-03 0.00E+00 1.11E-02 1.23E-02 1.57E-02 1.74E-02 2.30E-02 3.19E-04 30 FARM-DEPENDENT DECONTAMINATION DOSE 0.2966 3.65E-07 0.00E+00 1.12E-06 1.24E-06 1.59E-06 1.77E-06 2.38E-06 3.19E-04 30 INGESTION OF GRAINS 1.0000 1.50E-02 5.36E-03 5.05E-02 6.36E-02 7.64E-02 8.00E-02 1.12E-01 4.53E-05 62 INGESTION OF LEAF VEG 1.0000 2.78E-02 7.07E-03 7.83E-02 9.72E-02 2.58E-01 3.06E-01 4.83E-01 4.53E-05 62 INGESTION OF ROOT CROPS 1.0000 1.99E-02 7.20E-03 6.56E-02 8.07E-02 1.05E-01 1.09E-01 1.46E-01 4.53E-05 62 INGESTION OF FRUITS 1.0000 2.93E-02 1.07E-02 9.73E-02 1.07E-01 1.25E-01 1.34E-01 2.15E-01 4.53E-05 62 INGESTION OF LEGUMES 1.0000 1.70E-02 5.93E-03 5.44E-02 7.13E-02 8.32E-02 8.90E-02 1.25E-01 4.53E-05 62 INGESTION OF BEEF 1.0000 1.55E-01 5.56E-02 4.66E-01 6.36E-01 7.63E-01 7.97E-01 1.07E+00 4.87E-05 4 INGESTION OF MILK 1.0000 1.79E-01 5.70E-02 5.96E-01 7.37E-01 9.10E-01 9.96E-01 1.29E+00 4.87E-05 4 INGESTION OF POULTRY 1.0000 4.07E-02 1.30E-02 1.16E-01 1.53E-01 3.21E-01 3.51E-01 6.23E-01 4.53E-05 62 INGESTION OF OTHER MEAT CROPS 1.0000 9.22E-03 4.85E-03 2.26E-02 2.86E-02 6.19E-02 7.16E-02 1.18E-01 4.53E-05 62 ECONOMIC COST MEASURES ($) 0-80.5 km TOTAL ECONOMIC COSTS 0.7594 9.98E+04 2.54E+03 3.22E+05 3.46E+05 4.08E+05 4.38E+05 4.86E+05 1.83E-03 74 POP.-DEPENDENT COSTS 0.2966 9.37E+04 0.00E+00 NOT-FOUND NOT-FOUND NOT-FOUND NOT-FOUND 4.12E+05 1.83E-01 1 FARM-DEPENDENT COSTS 0.7594 6.11E+03 9.94E+02 2.03E+04 2.43E+04 4.88E+04 7.14E+04 7.36E+04 1.83E-03 74 POP.-DEPENDENT DECONTAMINATION COST 0.2966 2.00E+04 0.00E+00 NOT-FOUND NOT-FOUND NOT-FOUND NOT-FOUND 8.81E+04 1.83E-01 1 FARM-DEPENDENT DECONTAMINATION COST 0.2966 1.61E+01 0.00E+00 NOT-FOUND NOT-FOUND NOT-FOUND NOT-FOUND 7.04E+01 1.83E-01 1 POP.-DEPENDENT INTERDICTION COST 0.2966 7.36E+04 0.00E+00 NOT-FOUND NOT-FOUND NOT-FOUND NOT-FOUND 3.24E+05 1.83E-01 1 FARM-DEPENDENT INTERDICTION COST 0.7580 4.77E+03 7.10E+02 1.28E+04 1.58E+04 4.87E+04 5.28E+04 5.73E+04 1.83E-03 74 POP.-DEPENDENT CONDEMNATION COST 0.0000 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0 FARM-DEPENDENT CONDEMNATION COST 0.0000 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0 EMERGENCY PHASE COST 0.0000 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0 INTERMEDIATE PHASE COST 0.0000 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0
Calculation IP-CALC-09-00265, Rev. 0, Att. A.1, Page 84 11-NOV-09 19:34:05 PAGE 4 PROB QUANTILES PEAK PEAK PEAK NON-ZERO MEAN 50TH 90TH 95TH 99TH 99.5TH CONS PROB TRIAL ECONOMIC COST MEASURES ($) 0-80.5 km MILK DISPOSAL COST 0.7424 1.89E+01 1.11E+00 6.06E+01 9.49E+01 2.20E+02 2.60E+02 3.37E+02 1.23E-03 18 CROP DISPOSAL COST 0.7410 1.30E+03 1.95E+02 3.62E+03 4.29E+03 1.12E+04 1.30E+04 1.62E+04 1.83E-03 74
Calculation IP-CALC-09-00265, Rev. 0, Att. A.1, Page 85 XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX
Calculation IP-CALC-09-00265, Rev. 0, Att. A.1, Page 86 DATE AND TIME OF RUN = MACCS2 11-NOV-09 19:34:05 VERSION 1.13.1: last revised 1/8/04, K. McFadden "ATMOS" DESCRIPTION = ATMOS INPUT FOR IPEC CALCULATIONS "EARLY" DESCRIPTION = EARLY.IN, IPEC INPUT FROM THE EVACUATION TIME ESTIMATES "CHRONC" DESCRIPTION = CHRONC.IN - IPEC, "New" COMIDA2-Based Food Model SOURCE TERM 2 OF 8:
EARLY HIGH OVERALL RESULTS OBTAINED BY COMBINING 1 EMERGENCY RESPONSE COHORTS FROM "EARLY" WITH THE WEIGHTING FRACTIONS BELOW APPLIED TO THEM:
FRACTION OF THE PEOPLE COHORT 1 = NO EVACUATION, RELOCATION MODELS APPLY EVERYWHE 1.000 AND THEN MERGING THE 1 RESULTS ABOVE WITH THE SINGLE SET OF RESULTS FROM "CHRONC" DESCRIBED BELOW:
COHORT 2 = CHRONC.IN - IPEC, "New" COMIDA2-Based Food Model RESULTS WHICH ARE PRODUCED ONLY BY "EARLY" OR ONLY BY "CHRONC" ARE PRESENTED IN LATER SECTIONS.
11-NOV-09 19:34:05 PAGE 5 PROB QUANTILES PEAK PEAK PEAK NON-ZERO MEAN 50TH 90TH 95TH 99TH 99.5TH CONS PROB TRIAL HEALTH EFFECTS CASES CAN FAT/TOTAL 0-80.5 km 1.0000 4.03E+04 2.44E+04 9.18E+04 1.04E+05 1.17E+05 1.24E+05 1.76E+05 4.84E-05 146 CAN FAT/TOTAL 0-16.1 km 1.0000 6.22E+03 5.77E+03 1.03E+04 1.11E+04 1.33E+04 1.43E+04 2.02E+04 2.28E-04 120 POPULATION DOSE (Sv)
L-EDEWBODY TOT LIF 0-80.5 km 1.0000 6.51E+05 3.65E+05 1.58E+06 2.07E+06 2.82E+06 NOT-FOUND 2.86E+06 9.30E-03 149 POPULATION WEIGHTED RISK CAN FAT/TOTAL 0-16.1 km 1.0000 1.53E-02 1.27E-02 2.49E-02 2.95E-02 3.62E-02 3.93E-02 5.16E-02 2.28E-04 120
Calculation IP-CALC-09-00265, Rev. 0, Att. A.1, Page 87 DATE AND TIME OF RUN = MACCS2 11-NOV-09 19:34:05 VERSION 1.13.1: last revised 1/8/04, K. McFadden "ATMOS" DESCRIPTION = ATMOS INPUT FOR IPEC CALCULATIONS "EARLY" DESCRIPTION = EARLY.IN, IPEC INPUT FROM THE EVACUATION TIME ESTIMATES SOURCE TERM 2 OF 8:
EARLY HIGH RESULTS FOR A SINGLE EMERGENCY RESPONSE COHORT WITHOUT ANY WEIGHTING FRACTIONS BEING APPLIED COHORT 1 = NO EVACUATION, RELOCATION MODELS APPLY EVERYWHE 11-NOV-09 19:34:05 PAGE 6 PROB QUANTILES PEAK PEAK PEAK NON-ZERO MEAN 50TH 90TH 95TH 99TH 99.5TH CONS PROB TRIAL HEALTH EFFECTS CASES ERL FAT/TOTAL 0-80.5 km 0.9938 1.63E+02 6.78E+01 4.28E+02 5.17E+02 5.97E+02 6.35E+02 1.03E+03 1.33E-05 121 CAN FAT/TOTAL 0-80.5 km 1.0000 2.57E+04 1.65E+04 6.05E+04 8.31E+04 1.05E+05 1.09E+05 1.24E+05 2.85E-04 1 CAN FAT/TOTAL 0-16.1 km 1.0000 5.82E+03 5.43E+03 9.85E+03 1.08E+04 1.30E+04 1.40E+04 2.02E+04 2.28E-04 120 ERL FAT/TOTAL 0-16.1 km 0.9938 1.63E+02 6.78E+01 4.28E+02 5.17E+02 5.97E+02 6.35E+02 1.03E+03 1.33E-05 121 AVERAGE INDIVIDUAL RISK ERL FAT/TOTAL 0-0.3 km 0.9938 1.62E-01 1.34E-01 2.04E-01 2.08E-01 2.19E-01 2.23E-01 2.26E-01 3.11E-03 1 ERL FAT/TOTAL 0.3-1.6 km 0.8493 3.14E-02 2.13E-02 7.08E-02 7.32E-02 7.91E-02 8.17E-02 9.03E-02 6.28E-04 69 ERL FAT/TOTAL 1.6-3.2 km 0.5219 1.93E-03 2.17E-04 7.20E-03 1.13E-02 2.15E-02 2.28E-02 2.59E-02 1.23E-03 121 POPULATION DOSE (Sv)
L-EDEWBODY TOT LIF 0-80.5 km 1.0000 3.24E+05 2.06E+05 8.15E+05 1.02E+06 1.17E+06 1.24E+06 1.57E+06 2.85E-04 151 POPULATION WEIGHTED RISK ERL FAT/TOTAL 0-3.2 km 0.9938 9.72E-03 4.35E-03 2.60E-02 3.10E-02 3.58E-02 3.80E-02 5.79E-02 1.33E-05 121 CAN FAT/TOTAL 0-16.1 km 1.0000 1.49E-02 1.24E-02 2.47E-02 2.94E-02 3.52E-02 3.78E-02 5.16E-02 2.28E-04 120
Calculation IP-CALC-09-00265, Rev. 0, Att. A.1, Page 88 DATE AND TIME OF RUN = MACCS2 11-NOV-09 19:34:05 VERSION 1.13.1: last revised 1/8/04, K. McFadden "ATMOS" DESCRIPTION = ATMOS INPUT FOR IPEC CALCULATIONS "EARLY" DESCRIPTION = EARLY.IN, IPEC INPUT FROM THE EVACUATION TIME ESTIMATES "CHRONC" DESCRIPTION = CHRONC.IN - IPEC, "New" COMIDA2-Based Food Model SOURCE TERM 2 OF 8:
EARLY HIGH RESULTS FROM THE "CHRONC" MODULE ALONE COHORT 2 = CHRONC.IN - IPEC, "New" COMIDA2-Based Food Model 11-NOV-09 19:34:05 PAGE 7 PROB QUANTILES PEAK PEAK PEAK NON-ZERO MEAN 50TH 90TH 95TH 99TH 99.5TH CONS PROB TRIAL HEALTH EFFECTS CASES CAN FAT/TOTAL 0-80.5 km 1.0000 1.45E+04 7.11E+03 3.78E+04 4.71E+04 5.38E+04 5.57E+04 6.00E+04 1.18E-03 100 CAN FAT/TOTAL 0-16.1 km 1.0000 4.00E+02 3.55E+02 5.33E+02 5.73E+02 6.77E+02 7.21E+02 9.10E+02 2.57E-04 151 POPULATION DOSE (Sv)
L-EDEWBODY TOT LIF 0-80.5 km 1.0000 3.27E+05 1.75E+05 8.46E+05 1.01E+06 1.15E+06 1.22E+06 1.36E+06 1.18E-03 100 POPULATION WEIGHTED RISK CAN FAT/TOTAL 0-16.1 km 0.9544 3.70E-04 3.37E-04 6.25E-04 7.30E-04 9.42E-04 1.04E-03 1.47E-03 2.57E-04 151 L-EDEWBODY POP. DOSE (Sv) 0-80.5 km TOTAL LONG-TERM PATHWAYS DOSE 1.0000 3.27E+05 1.75E+05 8.46E+05 1.01E+06 1.15E+06 1.22E+06 1.36E+06 1.18E-03 100 LONG-TERM DIRECT EXPOSURE PATHWAYS 1.0000 2.59E+05 1.23E+05 6.26E+05 7.25E+05 9.25E+05 NOT-FOUND 9.35E+05 9.30E-03 149 TOTAL INGESTION PATHWAYS DOSE 1.0000 3.96E+03 3.55E+03 6.66E+03 7.43E+03 8.95E+03 9.70E+03 1.15E+04 4.57E-04 120 LONG-TERM GROUNDSHINE DOSE 1.0000 2.48E+05 1.13E+05 6.18E+05 7.19E+05 9.02E+05 NOT-FOUND 9.11E+05 9.30E-03 149 LONG-TERM RESUSPENSION DOSE 1.0000 1.03E+04 4.67E+03 2.29E+04 2.50E+04 3.05E+04 3.26E+04 3.75E+04 1.14E-03 78 WATER INGESTION DOSE 1.0000 3.81E+03 3.41E+03 6.55E+03 7.38E+03 8.82E+03 9.53E+03 1.15E+04 4.57E-04 120 POP.-DEPENDENT DECONTAMINATION DOSE 1.0000 6.45E+04 3.14E+04 1.62E+05 2.42E+05 3.54E+05 3.91E+05 4.78E+05 1.18E-03 100 FARM-DEPENDENT DECONTAMINATION DOSE 1.0000 3.71E+01 1.40E+01 1.03E+02 1.09E+02 1.26E+02 1.34E+02 1.92E+02 8.56E-05 149 INGESTION OF GRAINS 1.0000 3.21E+00 1.41E+00 8.26E+00 1.01E+01 1.33E+01 1.50E+01 2.63E+01 2.40E-05 51 INGESTION OF LEAF VEG 1.0000 2.55E+01 1.03E+01 6.84E+01 7.87E+01 1.02E+02 1.05E+02 1.29E+02 8.56E-05 149 INGESTION OF ROOT CROPS 1.0000 1.52E+01 6.35E+00 3.72E+01 4.51E+01 6.71E+01 7.09E+01 7.87E+01 8.56E-05 149 INGESTION OF FRUITS 1.0000 1.34E+01 5.91E+00 3.36E+01 3.95E+01 5.13E+01 5.29E+01 6.29E+01 8.56E-05 149 INGESTION OF LEGUMES 1.0000 2.96E+01 1.28E+01 7.74E+01 9.17E+01 1.10E+02 1.16E+02 1.56E+02 8.56E-05 149 INGESTION OF BEEF 1.0000 2.58E+01 9.23E+00 7.13E+01 1.29E+02 2.28E+02 2.57E+02 4.58E+02 2.29E-05 126 INGESTION OF MILK 1.0000 2.89E+01 1.13E+01 7.69E+01 1.29E+02 2.47E+02 2.96E+02 3.88E+02 8.56E-05 112 INGESTION OF POULTRY 1.0000 7.61E+00 2.43E+00 2.49E+01 3.86E+01 5.49E+01 5.85E+01 1.18E+02 5.71E-05 75 INGESTION OF OTHER MEAT CROPS 1.0000 3.27E+00 1.02E+00 9.14E+00 2.05E+01 2.73E+01 3.04E+01 3.55E+01 8.28E-04 109 ECONOMIC COST MEASURES ($) 0-80.5 km TOTAL ECONOMIC COSTS 1.0000 2.05E+11 1.17E+11 5.17E+11 6.26E+11 7.96E+11 8.57E+11 1.02E+12 1.18E-03 100 POP.-DEPENDENT COSTS 1.0000 2.05E+11 1.17E+11 5.17E+11 6.26E+11 7.96E+11 8.57E+11 1.02E+12 1.18E-03 100 FARM-DEPENDENT COSTS 1.0000 3.92E+08 1.99E+08 1.01E+09 1.04E+09 1.12E+09 1.16E+09 1.32E+09 2.57E-04 76 POP.-DEPENDENT DECONTAMINATION COST 1.0000 4.41E+10 1.81E+10 1.05E+11 1.13E+11 1.35E+11 1.45E+11 1.96E+11 2.85E-04 76 FARM-DEPENDENT DECONTAMINATION COST 1.0000 3.41E+07 1.44E+07 8.72E+07 1.01E+08 1.10E+08 1.15E+08 1.51E+08 2.85E-05 76 POP.-DEPENDENT INTERDICTION COST 1.0000 1.46E+11 7.49E+10 3.74E+11 4.71E+11 7.33E+11 7.68E+11 8.46E+11 1.18E-03 100 FARM-DEPENDENT INTERDICTION COST 1.0000 3.04E+08 1.13E+08 7.50E+08 8.02E+08 9.38E+08 1.00E+09 1.11E+09 2.57E-04 76 POP.-DEPENDENT CONDEMNATION COST 1.0000 1.48E+10 7.99E+09 4.08E+10 5.21E+10 6.34E+10 NOT-FOUND 6.61E+10 7.09E-03 39 FARM-DEPENDENT CONDEMNATION COST 1.0000 1.26E+07 7.33E+06 3.27E+07 5.09E+07 5.43E+07 5.59E+07 6.21E+07 3.75E-04 27 EMERGENCY PHASE COST 1.0000 2.16E+08 8.19E+07 4.27E+08 7.11E+08 2.06E+09 NOT-FOUND 2.43E+09 9.30E-03 77 INTERMEDIATE PHASE COST 0.0000 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0
Calculation IP-CALC-09-00265, Rev. 0, Att. A.1, Page 89 11-NOV-09 19:34:05 PAGE 8 PROB QUANTILES PEAK PEAK PEAK NON-ZERO MEAN 50TH 90TH 95TH 99TH 99.5TH CONS PROB TRIAL ECONOMIC COST MEASURES ($) 0-80.5 km MILK DISPOSAL COST 1.0000 9.96E+05 1.24E+05 2.84E+06 3.42E+06 5.00E+06 5.14E+06 6.29E+06 2.85E-05 76 CROP DISPOSAL COST 1.0000 4.11E+07 4.03E+07 6.07E+07 6.71E+07 7.55E+07 7.86E+07 8.95E+07 5.14E-04 76
Calculation IP-CALC-09-00265, Rev. 0, Att. A.1, Page 90 XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX
Calculation IP-CALC-09-00265, Rev. 0, Att. A.1, Page 91 DATE AND TIME OF RUN = MACCS2 11-NOV-09 19:34:05 VERSION 1.13.1: last revised 1/8/04, K. McFadden "ATMOS" DESCRIPTION = ATMOS INPUT FOR IPEC CALCULATIONS "EARLY" DESCRIPTION = EARLY.IN, IPEC INPUT FROM THE EVACUATION TIME ESTIMATES "CHRONC" DESCRIPTION = CHRONC.IN - IPEC, "New" COMIDA2-Based Food Model SOURCE TERM 3 OF 8:
EARLY MEDIUM OVERALL RESULTS OBTAINED BY COMBINING 1 EMERGENCY RESPONSE COHORTS FROM "EARLY" WITH THE WEIGHTING FRACTIONS BELOW APPLIED TO THEM:
FRACTION OF THE PEOPLE COHORT 1 = NO EVACUATION, RELOCATION MODELS APPLY EVERYWHE 1.000 AND THEN MERGING THE 1 RESULTS ABOVE WITH THE SINGLE SET OF RESULTS FROM "CHRONC" DESCRIBED BELOW:
COHORT 2 = CHRONC.IN - IPEC, "New" COMIDA2-Based Food Model RESULTS WHICH ARE PRODUCED ONLY BY "EARLY" OR ONLY BY "CHRONC" ARE PRESENTED IN LATER SECTIONS.
11-NOV-09 19:34:05 PAGE 9 PROB QUANTILES PEAK PEAK PEAK NON-ZERO MEAN 50TH 90TH 95TH 99TH 99.5TH CONS PROB TRIAL HEALTH EFFECTS CASES CAN FAT/TOTAL 0-80.5 km 1.0000 1.04E+04 7.02E+03 2.53E+04 3.03E+04 3.23E+04 3.33E+04 4.22E+04 1.38E-05 147 CAN FAT/TOTAL 0-16.1 km 1.0000 1.32E+03 1.15E+03 2.16E+03 2.41E+03 3.04E+03 3.13E+03 3.82E+03 5.71E-05 75 POPULATION DOSE (Sv)
L-EDEWBODY TOT LIF 0-80.5 km 1.0000 1.94E+05 1.13E+05 4.75E+05 6.04E+05 7.40E+05 7.65E+05 8.40E+05 6.99E-04 10 POPULATION WEIGHTED RISK CAN FAT/TOTAL 0-16.1 km 1.0000 3.08E-03 3.01E-03 5.21E-03 5.79E-03 7.13E-03 7.38E-03 9.28E-03 5.71E-05 75
Calculation IP-CALC-09-00265, Rev. 0, Att. A.1, Page 92 DATE AND TIME OF RUN = MACCS2 11-NOV-09 19:34:05 VERSION 1.13.1: last revised 1/8/04, K. McFadden "ATMOS" DESCRIPTION = ATMOS INPUT FOR IPEC CALCULATIONS "EARLY" DESCRIPTION = EARLY.IN, IPEC INPUT FROM THE EVACUATION TIME ESTIMATES SOURCE TERM 3 OF 8:
EARLY MEDIUM RESULTS FOR A SINGLE EMERGENCY RESPONSE COHORT WITHOUT ANY WEIGHTING FRACTIONS BEING APPLIED COHORT 1 = NO EVACUATION, RELOCATION MODELS APPLY EVERYWHE 11-NOV-09 19:34:05 PAGE 10 PROB QUANTILES PEAK PEAK PEAK NON-ZERO MEAN 50TH 90TH 95TH 99TH 99.5TH CONS PROB TRIAL HEALTH EFFECTS CASES ERL FAT/TOTAL 0-80.5 km 0.7430 4.81E+00 1.45E+00 1.63E+01 2.06E+01 2.31E+01 2.42E+01 2.82E+01 5.79E-04 86 CAN FAT/TOTAL 0-80.5 km 1.0000 4.63E+03 3.25E+03 1.03E+04 1.32E+04 2.04E+04 2.11E+04 2.79E+04 1.38E-05 147 CAN FAT/TOTAL 0-16.1 km 1.0000 1.06E+03 1.01E+03 1.80E+03 2.10E+03 2.57E+03 2.80E+03 3.50E+03 5.71E-05 75 ERL FAT/TOTAL 0-16.1 km 0.7430 4.81E+00 1.45E+00 1.63E+01 2.06E+01 2.31E+01 2.42E+01 2.82E+01 5.79E-04 86 AVERAGE INDIVIDUAL RISK ERL FAT/TOTAL 0-0.3 km 0.7430 2.28E-02 7.90E-03 7.14E-02 7.54E-02 8.55E-02 9.02E-02 1.04E-01 1.34E-03 86 ERL FAT/TOTAL 0.3-1.6 km 0.0289 1.14E-05 0.00E+00 0.00E+00 0.00E+00 4.48E-04 5.45E-04 7.66E-04 1.23E-03 121 ERL FAT/TOTAL 1.6-3.2 km 0.0000 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0 POPULATION DOSE (Sv)
L-EDEWBODY TOT LIF 0-80.5 km 1.0000 6.55E+04 4.09E+04 1.53E+05 2.14E+05 3.14E+05 3.33E+05 3.93E+05 6.99E-04 10 POPULATION WEIGHTED RISK ERL FAT/TOTAL 0-3.2 km 0.7430 2.89E-04 8.52E-05 1.01E-03 1.08E-03 1.27E-03 1.36E-03 1.69E-03 5.79E-04 86 CAN FAT/TOTAL 0-16.1 km 1.0000 2.72E-03 2.54E-03 4.62E-03 5.34E-03 6.79E-03 7.17E-03 8.96E-03 5.71E-05 75
Calculation IP-CALC-09-00265, Rev. 0, Att. A.1, Page 93 DATE AND TIME OF RUN = MACCS2 11-NOV-09 19:34:05 VERSION 1.13.1: last revised 1/8/04, K. McFadden "ATMOS" DESCRIPTION = ATMOS INPUT FOR IPEC CALCULATIONS "EARLY" DESCRIPTION = EARLY.IN, IPEC INPUT FROM THE EVACUATION TIME ESTIMATES "CHRONC" DESCRIPTION = CHRONC.IN - IPEC, "New" COMIDA2-Based Food Model SOURCE TERM 3 OF 8:
EARLY MEDIUM RESULTS FROM THE "CHRONC" MODULE ALONE COHORT 2 = CHRONC.IN - IPEC, "New" COMIDA2-Based Food Model 11-NOV-09 19:34:05 PAGE 11 PROB QUANTILES PEAK PEAK PEAK NON-ZERO MEAN 50TH 90TH 95TH 99TH 99.5TH CONS PROB TRIAL HEALTH EFFECTS CASES CAN FAT/TOTAL 0-80.5 km 1.0000 5.80E+03 2.91E+03 1.33E+04 1.66E+04 2.13E+04 2.22E+04 2.71E+04 2.00E-04 137 CAN FAT/TOTAL 0-16.1 km 1.0000 2.54E+02 2.37E+02 3.78E+02 4.29E+02 5.14E+02 5.27E+02 6.69E+02 6.34E-06 69 POPULATION DOSE (Sv)
L-EDEWBODY TOT LIF 0-80.5 km 1.0000 1.29E+05 6.61E+04 3.28E+05 3.78E+05 5.05E+05 5.21E+05 6.00E+05 2.00E-04 137 POPULATION WEIGHTED RISK CAN FAT/TOTAL 0-16.1 km 1.0000 3.57E-04 3.22E-04 5.46E-04 6.06E-04 7.08E-04 7.17E-04 8.12E-04 6.34E-06 69 L-EDEWBODY POP. DOSE (Sv) 0-80.5 km TOTAL LONG-TERM PATHWAYS DOSE 1.0000 1.29E+05 6.61E+04 3.28E+05 3.78E+05 5.05E+05 5.21E+05 6.00E+05 2.00E-04 137 LONG-TERM DIRECT EXPOSURE PATHWAYS 1.0000 1.18E+05 5.66E+04 3.06E+05 3.58E+05 5.02E+05 5.13E+05 5.68E+05 2.00E-04 137 TOTAL INGESTION PATHWAYS DOSE 1.0000 3.84E+02 3.30E+02 7.01E+02 7.31E+02 8.05E+02 8.39E+02 1.23E+03 8.82E-05 126 LONG-TERM GROUNDSHINE DOSE 1.0000 1.09E+05 4.92E+04 2.87E+05 3.20E+05 3.83E+05 4.14E+05 5.25E+05 2.00E-04 137 LONG-TERM RESUSPENSION DOSE 1.0000 8.75E+03 4.15E+03 2.33E+04 2.79E+04 3.40E+04 3.64E+04 4.38E+04 7.13E-04 143 WATER INGESTION DOSE 1.0000 2.58E+02 2.35E+02 4.31E+02 5.17E+02 6.76E+02 7.24E+02 8.56E+02 4.57E-04 120 POP.-DEPENDENT DECONTAMINATION DOSE 1.0000 1.04E+04 6.96E+03 2.31E+04 3.17E+04 5.28E+04 5.68E+04 7.91E+04 6.99E-04 10 FARM-DEPENDENT DECONTAMINATION DOSE 1.0000 6.72E+00 2.66E+00 2.02E+01 2.37E+01 3.14E+01 3.32E+01 4.08E+01 3.85E-04 100 INGESTION OF GRAINS 1.0000 4.09E+00 8.63E-01 1.29E+01 1.86E+01 2.60E+01 2.94E+01 3.86E+01 4.57E-04 14 INGESTION OF LEAF VEG 1.0000 1.06E+01 3.85E+00 2.85E+01 4.16E+01 9.00E+01 1.03E+02 1.39E+02 3.27E-05 70 INGESTION OF ROOT CROPS 1.0000 6.16E+00 2.15E+00 2.02E+01 2.62E+01 3.47E+01 3.77E+01 5.15E+01 4.57E-04 14 INGESTION OF FRUITS 1.0000 9.19E+00 3.35E+00 3.00E+01 3.66E+01 5.40E+01 5.97E+01 7.56E+01 4.57E-04 14 INGESTION OF LEGUMES 1.0000 7.40E+00 3.03E+00 2.08E+01 2.59E+01 3.37E+01 3.62E+01 4.63E+01 4.57E-04 14 INGESTION OF BEEF 1.0000 4.79E+01 1.95E+01 1.30E+02 1.82E+02 2.78E+02 3.06E+02 4.09E+02 2.29E-05 126 INGESTION OF MILK 1.0000 2.43E+01 7.81E+00 6.27E+01 1.05E+02 1.78E+02 2.07E+02 2.76E+02 3.16E-04 119 INGESTION OF POULTRY 1.0000 1.31E+01 5.23E+00 3.43E+01 4.36E+01 7.19E+01 7.69E+01 1.21E+02 3.27E-05 70 INGESTION OF OTHER MEAT CROPS 1.0000 3.80E+00 1.65E+00 1.02E+01 1.56E+01 2.22E+01 2.36E+01 3.18E+01 3.16E-04 98 ECONOMIC COST MEASURES ($) 0-80.5 km TOTAL ECONOMIC COSTS 1.0000 5.87E+10 2.74E+10 2.05E+11 2.35E+11 3.05E+11 3.14E+11 3.41E+11 6.99E-04 10 POP.-DEPENDENT COSTS 1.0000 5.85E+10 2.73E+10 2.05E+11 2.35E+11 3.05E+11 3.14E+11 3.41E+11 6.99E-04 10 FARM-DEPENDENT COSTS 1.0000 1.96E+08 8.74E+07 5.58E+08 6.89E+08 1.00E+09 1.01E+09 1.07E+09 8.56E-05 149 POP.-DEPENDENT DECONTAMINATION COST 1.0000 1.45E+10 6.64E+09 3.76E+10 5.43E+10 8.64E+10 9.99E+10 1.12E+11 6.99E-04 10 FARM-DEPENDENT DECONTAMINATION COST 1.0000 1.27E+07 5.30E+06 3.28E+07 3.82E+07 5.06E+07 5.18E+07 5.92E+07 8.56E-05 149 POP.-DEPENDENT INTERDICTION COST 1.0000 4.31E+10 1.99E+10 1.12E+11 1.50E+11 2.07E+11 2.12E+11 2.28E+11 6.99E-04 10 FARM-DEPENDENT INTERDICTION COST 1.0000 1.61E+08 5.23E+07 4.75E+08 6.20E+08 7.47E+08 7.74E+08 9.53E+08 8.56E-05 149 POP.-DEPENDENT CONDEMNATION COST 0.9876 9.04E+08 6.65E+08 1.78E+09 2.19E+09 3.05E+09 3.38E+09 5.57E+09 1.14E-04 120 FARM-DEPENDENT CONDEMNATION COST 0.9876 2.80E+05 2.40E+05 5.78E+05 7.74E+05 1.08E+06 1.16E+06 2.04E+06 2.85E-05 114 EMERGENCY PHASE COST 1.0000 1.52E+07 1.05E+07 3.50E+07 5.49E+07 7.12E+07 7.28E+07 7.76E+07 6.37E-04 50 INTERMEDIATE PHASE COST 0.0000 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0
Calculation IP-CALC-09-00265, Rev. 0, Att. A.1, Page 94 11-NOV-09 19:34:05 PAGE 12 PROB QUANTILES PEAK PEAK PEAK NON-ZERO MEAN 50TH 90TH 95TH 99TH 99.5TH CONS PROB TRIAL ECONOMIC COST MEASURES ($) 0-80.5 km MILK DISPOSAL COST 1.0000 6.94E+05 4.82E+04 2.30E+06 3.03E+06 4.17E+06 4.78E+06 6.26E+06 2.85E-05 76 CROP DISPOSAL COST 1.0000 2.14E+07 1.66E+07 4.84E+07 5.44E+07 6.79E+07 7.20E+07 8.38E+07 4.00E-04 76
Calculation IP-CALC-09-00265, Rev. 0, Att. A.1, Page 95 XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX
Calculation IP-CALC-09-00265, Rev. 0, Att. A.1, Page 96 DATE AND TIME OF RUN = MACCS2 11-NOV-09 19:34:05 VERSION 1.13.1: last revised 1/8/04, K. McFadden "ATMOS" DESCRIPTION = ATMOS INPUT FOR IPEC CALCULATIONS "EARLY" DESCRIPTION = EARLY.IN, IPEC INPUT FROM THE EVACUATION TIME ESTIMATES "CHRONC" DESCRIPTION = CHRONC.IN - IPEC, "New" COMIDA2-Based Food Model SOURCE TERM 4 OF 8:
EARLY LOW OVERALL RESULTS OBTAINED BY COMBINING 1 EMERGENCY RESPONSE COHORTS FROM "EARLY" WITH THE WEIGHTING FRACTIONS BELOW APPLIED TO THEM:
FRACTION OF THE PEOPLE COHORT 1 = NO EVACUATION, RELOCATION MODELS APPLY EVERYWHE 1.000 AND THEN MERGING THE 1 RESULTS ABOVE WITH THE SINGLE SET OF RESULTS FROM "CHRONC" DESCRIBED BELOW:
COHORT 2 = CHRONC.IN - IPEC, "New" COMIDA2-Based Food Model RESULTS WHICH ARE PRODUCED ONLY BY "EARLY" OR ONLY BY "CHRONC" ARE PRESENTED IN LATER SECTIONS.
11-NOV-09 19:34:05 PAGE 13 PROB QUANTILES PEAK PEAK PEAK NON-ZERO MEAN 50TH 90TH 95TH 99TH 99.5TH CONS PROB TRIAL HEALTH EFFECTS CASES CAN FAT/TOTAL 0-80.5 km 1.0000 3.71E+03 1.88E+03 9.19E+03 1.14E+04 1.70E+04 2.00E+04 2.40E+04 1.73E-05 56 CAN FAT/TOTAL 0-16.1 km 1.0000 3.27E+02 3.06E+02 5.18E+02 5.77E+02 7.32E+02 8.00E+02 9.07E+02 1.86E-03 74 POPULATION DOSE (Sv)
L-EDEWBODY TOT LIF 0-80.5 km 1.0000 7.93E+04 4.02E+04 1.96E+05 3.05E+05 4.22E+05 4.85E+05 5.25E+05 1.73E-05 56 POPULATION WEIGHTED RISK CAN FAT/TOTAL 0-16.1 km 1.0000 7.72E-04 7.29E-04 1.20E-03 1.36E-03 1.81E-03 2.02E-03 2.15E-03 1.86E-03 74
Calculation IP-CALC-09-00265, Rev. 0, Att. A.1, Page 97 DATE AND TIME OF RUN = MACCS2 11-NOV-09 19:34:05 VERSION 1.13.1: last revised 1/8/04, K. McFadden "ATMOS" DESCRIPTION = ATMOS INPUT FOR IPEC CALCULATIONS "EARLY" DESCRIPTION = EARLY.IN, IPEC INPUT FROM THE EVACUATION TIME ESTIMATES SOURCE TERM 4 OF 8:
EARLY LOW RESULTS FOR A SINGLE EMERGENCY RESPONSE COHORT WITHOUT ANY WEIGHTING FRACTIONS BEING APPLIED COHORT 1 = NO EVACUATION, RELOCATION MODELS APPLY EVERYWHE 11-NOV-09 19:34:05 PAGE 14 PROB QUANTILES PEAK PEAK PEAK NON-ZERO MEAN 50TH 90TH 95TH 99TH 99.5TH CONS PROB TRIAL HEALTH EFFECTS CASES ERL FAT/TOTAL 0-80.5 km 0.0832 3.39E-03 0.00E+00 0.00E+00 1.25E-02 8.96E-02 1.09E-01 1.82E-01 6.53E-04 121 CAN FAT/TOTAL 0-80.5 km 1.0000 6.05E+02 4.75E+02 1.18E+03 1.56E+03 2.09E+03 2.16E+03 2.81E+03 1.38E-05 147 CAN FAT/TOTAL 0-16.1 km 1.0000 1.85E+02 1.64E+02 3.27E+02 3.68E+02 4.85E+02 5.31E+02 5.97E+02 1.86E-03 74 ERL FAT/TOTAL 0-16.1 km 0.0832 3.39E-03 0.00E+00 0.00E+00 1.25E-02 8.96E-02 1.09E-01 1.82E-01 6.53E-04 121 AVERAGE INDIVIDUAL RISK ERL FAT/TOTAL 0-0.3 km 0.0832 1.44E-05 0.00E+00 0.00E+00 5.98E-05 4.19E-04 5.38E-04 6.68E-04 1.23E-03 121 ERL FAT/TOTAL 0.3-1.6 km 0.0000 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0 ERL FAT/TOTAL 1.6-3.2 km 0.0000 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0 POPULATION DOSE (Sv)
L-EDEWBODY TOT LIF 0-80.5 km 1.0000 1.04E+04 7.57E+03 2.23E+04 3.02E+04 3.33E+04 3.48E+04 5.14E+04 1.38E-05 147 POPULATION WEIGHTED RISK ERL FAT/TOTAL 0-3.2 km 0.0832 2.03E-07 0.00E+00 0.00E+00 8.81E-07 4.45E-06 7.39E-06 1.09E-05 6.53E-04 121 CAN FAT/TOTAL 0-16.1 km 1.0000 4.75E-04 4.27E-04 8.36E-04 9.79E-04 1.22E-03 1.34E-03 1.53E-03 1.86E-03 74
Calculation IP-CALC-09-00265, Rev. 0, Att. A.1, Page 98 DATE AND TIME OF RUN = MACCS2 11-NOV-09 19:34:05 VERSION 1.13.1: last revised 1/8/04, K. McFadden "ATMOS" DESCRIPTION = ATMOS INPUT FOR IPEC CALCULATIONS "EARLY" DESCRIPTION = EARLY.IN, IPEC INPUT FROM THE EVACUATION TIME ESTIMATES "CHRONC" DESCRIPTION = CHRONC.IN - IPEC, "New" COMIDA2-Based Food Model SOURCE TERM 4 OF 8:
EARLY LOW RESULTS FROM THE "CHRONC" MODULE ALONE COHORT 2 = CHRONC.IN - IPEC, "New" COMIDA2-Based Food Model 11-NOV-09 19:34:05 PAGE 15 PROB QUANTILES PEAK PEAK PEAK NON-ZERO MEAN 50TH 90TH 95TH 99TH 99.5TH CONS PROB TRIAL HEALTH EFFECTS CASES CAN FAT/TOTAL 0-80.5 km 1.0000 3.10E+03 1.41E+03 8.18E+03 1.08E+04 1.62E+04 1.93E+04 2.16E+04 1.73E-05 56 CAN FAT/TOTAL 0-16.1 km 1.0000 1.42E+02 1.22E+02 2.14E+02 2.35E+02 2.90E+02 3.08E+02 3.61E+02 3.42E-04 72 POPULATION DOSE (Sv)
L-EDEWBODY TOT LIF 0-80.5 km 1.0000 6.89E+04 3.27E+04 1.75E+05 2.60E+05 3.26E+05 3.40E+05 4.80E+05 1.73E-05 56 POPULATION WEIGHTED RISK CAN FAT/TOTAL 0-16.1 km 1.0000 2.98E-04 2.87E-04 4.69E-04 5.17E-04 5.81E-04 6.11E-04 7.32E-04 3.42E-04 72 L-EDEWBODY POP. DOSE (Sv) 0-80.5 km TOTAL LONG-TERM PATHWAYS DOSE 1.0000 6.89E+04 3.27E+04 1.75E+05 2.60E+05 3.26E+05 3.40E+05 4.80E+05 1.73E-05 56 LONG-TERM DIRECT EXPOSURE PATHWAYS 1.0000 6.80E+04 3.17E+04 1.74E+05 2.60E+05 3.26E+05 3.40E+05 4.80E+05 1.73E-05 56 TOTAL INGESTION PATHWAYS DOSE 1.0000 1.58E+02 1.08E+02 3.28E+02 3.78E+02 5.06E+02 5.24E+02 6.36E+02 8.56E-05 143 LONG-TERM GROUNDSHINE DOSE 1.0000 6.49E+04 3.03E+04 1.62E+05 2.51E+05 3.23E+05 3.35E+05 4.58E+05 1.73E-05 56 LONG-TERM RESUSPENSION DOSE 1.0000 3.02E+03 1.32E+03 8.17E+03 1.08E+04 1.62E+04 1.93E+04 2.17E+04 1.73E-05 56 WATER INGESTION DOSE 1.0000 5.64E+01 5.34E+01 9.68E+01 1.08E+02 1.31E+02 1.43E+02 1.92E+02 4.57E-04 120 POP.-DEPENDENT DECONTAMINATION DOSE 1.0000 8.13E+02 6.69E+02 1.47E+03 1.85E+03 2.40E+03 2.63E+03 6.22E+03 1.18E-03 100 FARM-DEPENDENT DECONTAMINATION DOSE 1.0000 4.91E-01 2.42E-01 1.28E+00 2.10E+00 3.14E+00 3.48E+00 4.35E+00 1.11E-03 72 INGESTION OF GRAINS 1.0000 3.47E+00 7.15E-01 1.11E+01 1.35E+01 2.04E+01 2.15E+01 3.01E+01 8.56E-05 143 INGESTION OF LEAF VEG 1.0000 6.73E+00 1.59E+00 1.75E+01 2.58E+01 7.17E+01 8.01E+01 9.09E+01 2.28E-03 77 INGESTION OF ROOT CROPS 1.0000 4.71E+00 1.03E+00 1.36E+01 1.82E+01 2.62E+01 3.00E+01 4.09E+01 8.56E-05 143 INGESTION OF FRUITS 1.0000 7.10E+00 1.81E+00 2.24E+01 2.72E+01 3.95E+01 4.59E+01 6.01E+01 8.56E-05 143 INGESTION OF LEGUMES 1.0000 4.34E+00 1.36E+00 1.25E+01 1.58E+01 2.36E+01 2.68E+01 3.49E+01 8.56E-05 143 INGESTION OF BEEF 1.0000 3.60E+01 1.45E+01 1.00E+02 1.19E+02 1.76E+02 2.03E+02 2.78E+02 8.56E-05 143 INGESTION OF MILK 1.0000 2.65E+01 1.12E+01 7.07E+01 8.73E+01 1.29E+02 1.49E+02 1.60E+02 3.62E-03 15 INGESTION OF POULTRY 1.0000 1.02E+01 4.07E+00 2.38E+01 3.27E+01 7.38E+01 8.51E+01 1.03E+02 2.28E-03 77 INGESTION OF OTHER MEAT CROPS 1.0000 2.65E+00 1.28E+00 6.63E+00 1.00E+01 1.33E+01 1.51E+01 1.74E+01 2.28E-03 77 ECONOMIC COST MEASURES ($) 0-80.5 km TOTAL ECONOMIC COSTS 1.0000 6.39E+09 3.60E+09 1.32E+10 2.13E+10 3.79E+10 4.25E+10 1.24E+11 1.18E-03 100 POP.-DEPENDENT COSTS 1.0000 6.30E+09 3.42E+09 1.31E+10 2.13E+10 3.79E+10 4.25E+10 1.24E+11 1.18E-03 100 FARM-DEPENDENT COSTS 1.0000 9.33E+07 3.23E+07 3.06E+08 3.57E+08 5.02E+08 5.14E+08 5.92E+08 8.56E-05 149 POP.-DEPENDENT DECONTAMINATION COST 1.0000 1.43E+09 7.80E+08 3.61E+09 5.75E+09 8.29E+09 9.02E+09 2.65E+10 1.18E-03 100 FARM-DEPENDENT DECONTAMINATION COST 1.0000 1.98E+06 5.79E+05 6.32E+06 8.54E+06 1.16E+07 1.26E+07 1.75E+07 3.71E-04 100 POP.-DEPENDENT INTERDICTION COST 1.0000 4.76E+09 2.62E+09 1.16E+10 1.76E+10 2.57E+10 2.92E+10 9.71E+10 1.87E-03 100 FARM-DEPENDENT INTERDICTION COST 1.0000 7.94E+07 1.84E+07 2.72E+08 3.36E+08 4.81E+08 5.05E+08 5.47E+08 8.56E-05 149 POP.-DEPENDENT CONDEMNATION COST 0.9731 1.01E+08 1.02E+08 2.34E+08 3.08E+08 3.79E+08 4.14E+08 1.05E+09 6.79E-06 52 FARM-DEPENDENT CONDEMNATION COST 0.9184 2.79E+04 8.08E+03 7.83E+04 8.59E+04 1.14E+05 1.37E+05 2.90E+05 1.18E-04 84 EMERGENCY PHASE COST 1.0000 2.02E+06 1.63E+06 4.05E+06 5.54E+06 8.09E+06 8.85E+06 1.25E+07 2.28E-04 120 INTERMEDIATE PHASE COST 0.0000 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0
Calculation IP-CALC-09-00265, Rev. 0, Att. A.1, Page 99 11-NOV-09 19:34:05 PAGE 16 PROB QUANTILES PEAK PEAK PEAK NON-ZERO MEAN 50TH 90TH 95TH 99TH 99.5TH CONS PROB TRIAL ECONOMIC COST MEASURES ($) 0-80.5 km MILK DISPOSAL COST 1.0000 3.93E+05 2.79E+04 1.27E+06 1.72E+06 2.97E+06 3.39E+06 5.51E+06 6.28E-04 137 CROP DISPOSAL COST 1.0000 1.15E+07 8.81E+06 2.68E+07 3.26E+07 4.43E+07 5.02E+07 5.74E+07 5.14E-04 76
Calculation IP-CALC-09-00265, Rev. 0, Att. A.1, Page 100 XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX
Calculation IP-CALC-09-00265, Rev. 0, Att. A.1, Page 101 DATE AND TIME OF RUN = MACCS2 11-NOV-09 19:34:05 VERSION 1.13.1: last revised 1/8/04, K. McFadden "ATMOS" DESCRIPTION = ATMOS INPUT FOR IPEC CALCULATIONS "EARLY" DESCRIPTION = EARLY.IN, IPEC INPUT FROM THE EVACUATION TIME ESTIMATES "CHRONC" DESCRIPTION = CHRONC.IN - IPEC, "New" COMIDA2-Based Food Model SOURCE TERM 5 OF 8:
LATE HIGH OVERALL RESULTS OBTAINED BY COMBINING 1 EMERGENCY RESPONSE COHORTS FROM "EARLY" WITH THE WEIGHTING FRACTIONS BELOW APPLIED TO THEM:
FRACTION OF THE PEOPLE COHORT 1 = NO EVACUATION, RELOCATION MODELS APPLY EVERYWHE 1.000 AND THEN MERGING THE 1 RESULTS ABOVE WITH THE SINGLE SET OF RESULTS FROM "CHRONC" DESCRIBED BELOW:
COHORT 2 = CHRONC.IN - IPEC, "New" COMIDA2-Based Food Model RESULTS WHICH ARE PRODUCED ONLY BY "EARLY" OR ONLY BY "CHRONC" ARE PRESENTED IN LATER SECTIONS.
11-NOV-09 19:34:05 PAGE 17 PROB QUANTILES PEAK PEAK PEAK NON-ZERO MEAN 50TH 90TH 95TH 99TH 99.5TH CONS PROB TRIAL HEALTH EFFECTS CASES CAN FAT/TOTAL 0-80.5 km 1.0000 7.32E+03 4.07E+03 1.65E+04 2.10E+04 2.81E+04 3.12E+04 3.74E+04 1.20E-03 23 CAN FAT/TOTAL 0-16.1 km 1.0000 6.39E+02 5.91E+02 1.03E+03 1.07E+03 1.18E+03 1.22E+03 1.58E+03 5.71E-05 90 POPULATION DOSE (Sv)
L-EDEWBODY TOT LIF 0-80.5 km 1.0000 1.63E+05 9.05E+04 4.04E+05 5.12E+05 6.43E+05 7.08E+05 8.42E+05 1.20E-03 23 POPULATION WEIGHTED RISK CAN FAT/TOTAL 0-16.1 km 1.0000 1.46E-03 1.24E-03 2.37E-03 2.73E-03 3.12E-03 3.20E-03 3.75E-03 5.71E-05 90
Calculation IP-CALC-09-00265, Rev. 0, Att. A.1, Page 102 DATE AND TIME OF RUN = MACCS2 11-NOV-09 19:34:05 VERSION 1.13.1: last revised 1/8/04, K. McFadden "ATMOS" DESCRIPTION = ATMOS INPUT FOR IPEC CALCULATIONS "EARLY" DESCRIPTION = EARLY.IN, IPEC INPUT FROM THE EVACUATION TIME ESTIMATES SOURCE TERM 5 OF 8:
LATE HIGH RESULTS FOR A SINGLE EMERGENCY RESPONSE COHORT WITHOUT ANY WEIGHTING FRACTIONS BEING APPLIED COHORT 1 = NO EVACUATION, RELOCATION MODELS APPLY EVERYWHE 11-NOV-09 19:34:05 PAGE 18 PROB QUANTILES PEAK PEAK PEAK NON-ZERO MEAN 50TH 90TH 95TH 99TH 99.5TH CONS PROB TRIAL HEALTH EFFECTS CASES ERL FAT/TOTAL 0-80.5 km 0.2844 9.68E-02 0.00E+00 3.72E-01 5.03E-01 9.63E-01 1.12E+00 2.27E+00 2.59E-04 30 CAN FAT/TOTAL 0-80.5 km 1.0000 1.66E+03 1.20E+03 3.39E+03 4.41E+03 5.89E+03 6.44E+03 7.78E+03 1.00E-03 98 CAN FAT/TOTAL 0-16.1 km 1.0000 4.21E+02 3.73E+02 7.56E+02 8.58E+02 1.02E+03 1.04E+03 1.19E+03 5.71E-05 90 ERL FAT/TOTAL 0-16.1 km 0.2844 9.68E-02 0.00E+00 3.72E-01 5.03E-01 9.63E-01 1.12E+00 2.27E+00 2.59E-04 30 AVERAGE INDIVIDUAL RISK ERL FAT/TOTAL 0-0.3 km 0.2844 4.63E-04 0.00E+00 1.68E-03 2.20E-03 3.18E-03 3.81E-03 8.33E-03 5.99E-04 30 ERL FAT/TOTAL 0.3-1.6 km 0.0000 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0 ERL FAT/TOTAL 1.6-3.2 km 0.0000 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0 POPULATION DOSE (Sv)
L-EDEWBODY TOT LIF 0-80.5 km 1.0000 3.62E+04 2.90E+04 8.00E+04 1.04E+05 1.32E+05 1.46E+05 1.85E+05 1.00E-03 98 POPULATION WEIGHTED RISK ERL FAT/TOTAL 0-3.2 km 0.2844 5.81E-06 0.00E+00 2.17E-05 3.00E-05 4.78E-05 7.47E-05 1.36E-04 2.59E-04 30 CAN FAT/TOTAL 0-16.1 km 1.0000 1.08E-03 1.01E-03 1.86E-03 2.09E-03 2.40E-03 2.55E-03 3.05E-03 5.71E-05 90
Calculation IP-CALC-09-00265, Rev. 0, Att. A.1, Page 103 DATE AND TIME OF RUN = MACCS2 11-NOV-09 19:34:05 VERSION 1.13.1: last revised 1/8/04, K. McFadden "ATMOS" DESCRIPTION = ATMOS INPUT FOR IPEC CALCULATIONS "EARLY" DESCRIPTION = EARLY.IN, IPEC INPUT FROM THE EVACUATION TIME ESTIMATES "CHRONC" DESCRIPTION = CHRONC.IN - IPEC, "New" COMIDA2-Based Food Model SOURCE TERM 5 OF 8:
LATE HIGH RESULTS FROM THE "CHRONC" MODULE ALONE COHORT 2 = CHRONC.IN - IPEC, "New" COMIDA2-Based Food Model 11-NOV-09 19:34:05 PAGE 19 PROB QUANTILES PEAK PEAK PEAK NON-ZERO MEAN 50TH 90TH 95TH 99TH 99.5TH CONS PROB TRIAL HEALTH EFFECTS CASES CAN FAT/TOTAL 0-80.5 km 1.0000 5.66E+03 2.68E+03 1.41E+04 1.88E+04 2.36E+04 2.55E+04 3.20E+04 1.20E-03 23 CAN FAT/TOTAL 0-16.1 km 1.0000 2.18E+02 2.07E+02 3.11E+02 3.23E+02 3.53E+02 3.66E+02 6.19E+02 1.73E-06 54 POPULATION DOSE (Sv)
L-EDEWBODY TOT LIF 0-80.5 km 1.0000 1.27E+05 6.07E+04 3.32E+05 3.87E+05 5.30E+05 5.80E+05 7.17E+05 1.20E-03 23 POPULATION WEIGHTED RISK CAN FAT/TOTAL 0-16.1 km 1.0000 3.85E-04 3.43E-04 6.06E-04 6.96E-04 7.45E-04 7.66E-04 1.13E-03 1.73E-06 54 L-EDEWBODY POP. DOSE (Sv) 0-80.5 km TOTAL LONG-TERM PATHWAYS DOSE 1.0000 1.27E+05 6.07E+04 3.32E+05 3.87E+05 5.30E+05 5.80E+05 7.17E+05 1.20E-03 23 LONG-TERM DIRECT EXPOSURE PATHWAYS 1.0000 1.21E+05 5.64E+04 3.18E+05 3.71E+05 5.19E+05 5.70E+05 6.91E+05 1.20E-03 23 TOTAL INGESTION PATHWAYS DOSE 1.0000 3.95E+02 3.45E+02 7.00E+02 7.34E+02 8.20E+02 8.60E+02 1.07E+03 8.82E-05 126 LONG-TERM GROUNDSHINE DOSE 1.0000 1.19E+05 5.50E+04 3.15E+05 3.68E+05 5.15E+05 5.63E+05 6.77E+05 1.20E-03 23 LONG-TERM RESUSPENSION DOSE 1.0000 2.66E+03 1.20E+03 7.17E+03 8.28E+03 1.10E+04 1.22E+04 1.49E+04 1.20E-03 67 WATER INGESTION DOSE 1.0000 3.39E+02 3.01E+02 6.09E+02 7.05E+02 7.60E+02 7.84E+02 1.04E+03 1.04E-05 146 POP.-DEPENDENT DECONTAMINATION DOSE 1.0000 4.91E+03 3.51E+03 1.06E+04 1.37E+04 2.24E+04 2.59E+04 3.44E+04 1.00E-03 98 FARM-DEPENDENT DECONTAMINATION DOSE 1.0000 3.35E+00 1.49E+00 1.01E+01 1.10E+01 1.33E+01 1.45E+01 2.02E+01 3.28E-04 98 INGESTION OF GRAINS 1.0000 1.98E+00 6.15E-01 6.67E+00 8.39E+00 1.08E+01 1.14E+01 1.64E+01 3.35E-05 51 INGESTION OF LEAF VEG 1.0000 4.28E+00 1.59E+00 1.16E+01 1.55E+01 3.06E+01 3.28E+01 4.91E+01 8.56E-05 77 INGESTION OF ROOT CROPS 1.0000 2.89E+00 1.12E+00 9.39E+00 1.07E+01 1.27E+01 1.37E+01 2.19E+01 2.40E-05 51 INGESTION OF FRUITS 1.0000 5.30E+00 2.41E+00 1.38E+01 1.97E+01 2.30E+01 2.44E+01 3.38E+01 2.40E-05 51 INGESTION OF LEGUMES 1.0000 3.24E+00 1.47E+00 9.29E+00 1.05E+01 1.20E+01 1.27E+01 2.00E+01 2.40E-05 51 INGESTION OF BEEF 1.0000 1.77E+01 7.11E+00 5.33E+01 7.45E+01 1.03E+02 1.08E+02 1.63E+02 2.29E-05 126 INGESTION OF MILK 1.0000 1.14E+01 4.01E+00 3.56E+01 5.09E+01 7.54E+01 8.26E+01 1.36E+02 2.29E-05 126 INGESTION OF POULTRY 1.0000 6.15E+00 2.46E+00 1.42E+01 1.93E+01 4.41E+01 5.12E+01 6.15E+01 8.56E-05 77 INGESTION OF OTHER MEAT CROPS 1.0000 2.96E+00 1.13E+00 1.01E+01 1.33E+01 2.08E+01 2.17E+01 2.59E+01 3.71E-04 100 ECONOMIC COST MEASURES ($) 0-80.5 km TOTAL ECONOMIC COSTS 1.0000 4.64E+10 2.24E+10 1.31E+11 2.07E+11 2.41E+11 2.57E+11 2.99E+11 1.00E-03 98 POP.-DEPENDENT COSTS 1.0000 4.61E+10 2.23E+10 1.31E+11 2.07E+11 2.41E+11 2.57E+11 2.99E+11 1.00E-03 98 FARM-DEPENDENT COSTS 1.0000 2.45E+08 1.27E+08 7.15E+08 7.70E+08 9.14E+08 9.84E+08 1.06E+09 3.27E-05 150 POP.-DEPENDENT DECONTAMINATION COST 1.0000 1.07E+10 5.02E+09 2.97E+10 3.99E+10 5.84E+10 6.45E+10 8.84E+10 1.00E-03 98 FARM-DEPENDENT DECONTAMINATION COST 1.0000 9.58E+06 3.65E+06 2.71E+07 3.20E+07 3.99E+07 4.38E+07 5.39E+07 3.16E-04 98 POP.-DEPENDENT INTERDICTION COST 1.0000 3.41E+10 1.39E+10 1.00E+11 1.14E+11 1.54E+11 1.75E+11 2.10E+11 1.00E-03 98 FARM-DEPENDENT INTERDICTION COST 1.0000 2.02E+08 6.90E+07 6.32E+08 7.15E+08 7.68E+08 7.92E+08 9.90E+08 3.27E-05 150 POP.-DEPENDENT CONDEMNATION COST 1.0000 1.28E+09 1.08E+09 2.69E+09 3.27E+09 4.53E+09 5.04E+09 5.78E+09 1.20E-04 26 FARM-DEPENDENT CONDEMNATION COST 1.0000 4.24E+05 3.43E+05 9.08E+05 1.05E+06 1.26E+06 1.36E+06 3.22E+06 2.04E-05 146 EMERGENCY PHASE COST 1.0000 7.32E+06 7.04E+06 1.15E+07 1.28E+07 1.64E+07 1.82E+07 6.87E+07 1.84E-04 145 INTERMEDIATE PHASE COST 0.0000 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0
Calculation IP-CALC-09-00265, Rev. 0, Att. A.1, Page 104 11-NOV-09 19:34:05 PAGE 20 PROB QUANTILES PEAK PEAK PEAK NON-ZERO MEAN 50TH 90TH 95TH 99TH 99.5TH CONS PROB TRIAL ECONOMIC COST MEASURES ($) 0-80.5 km MILK DISPOSAL COST 1.0000 9.07E+05 1.14E+05 2.73E+06 3.38E+06 5.02E+06 5.16E+06 6.29E+06 3.40E-05 150 CROP DISPOSAL COST 1.0000 3.19E+07 3.02E+07 5.59E+07 6.10E+07 7.10E+07 7.23E+07 8.38E+07 2.16E-05 150
Calculation IP-CALC-09-00265, Rev. 0, Att. A.1, Page 105 XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX
Calculation IP-CALC-09-00265, Rev. 0, Att. A.1, Page 106 DATE AND TIME OF RUN = MACCS2 11-NOV-09 19:34:05 VERSION 1.13.1: last revised 1/8/04, K. McFadden "ATMOS" DESCRIPTION = ATMOS INPUT FOR IPEC CALCULATIONS "EARLY" DESCRIPTION = EARLY.IN, IPEC INPUT FROM THE EVACUATION TIME ESTIMATES "CHRONC" DESCRIPTION = CHRONC.IN - IPEC, "New" COMIDA2-Based Food Model SOURCE TERM 6 OF 8:
LATE MEDIUM OVERALL RESULTS OBTAINED BY COMBINING 1 EMERGENCY RESPONSE COHORTS FROM "EARLY" WITH THE WEIGHTING FRACTIONS BELOW APPLIED TO THEM:
FRACTION OF THE PEOPLE COHORT 1 = NO EVACUATION, RELOCATION MODELS APPLY EVERYWHE 1.000 AND THEN MERGING THE 1 RESULTS ABOVE WITH THE SINGLE SET OF RESULTS FROM "CHRONC" DESCRIBED BELOW:
COHORT 2 = CHRONC.IN - IPEC, "New" COMIDA2-Based Food Model RESULTS WHICH ARE PRODUCED ONLY BY "EARLY" OR ONLY BY "CHRONC" ARE PRESENTED IN LATER SECTIONS.
11-NOV-09 19:34:05 PAGE 21 PROB QUANTILES PEAK PEAK PEAK NON-ZERO MEAN 50TH 90TH 95TH 99TH 99.5TH CONS PROB TRIAL HEALTH EFFECTS CASES CAN FAT/TOTAL 0-80.5 km 1.0000 3.15E+03 1.56E+03 7.98E+03 1.04E+04 1.41E+04 1.61E+04 2.02E+04 1.26E-03 16 CAN FAT/TOTAL 0-16.1 km 1.0000 2.92E+02 2.61E+02 5.05E+02 5.32E+02 6.00E+02 6.32E+02 7.48E+02 1.14E-04 78 POPULATION DOSE (Sv)
L-EDEWBODY TOT LIF 0-80.5 km 1.0000 6.87E+04 3.58E+04 1.76E+05 2.53E+05 3.49E+05 3.79E+05 4.48E+05 1.26E-03 16 POPULATION WEIGHTED RISK CAN FAT/TOTAL 0-16.1 km 1.0000 6.88E-04 6.16E-04 1.05E-03 1.10E-03 1.24E-03 1.31E-03 1.74E-03 1.14E-04 78
Calculation IP-CALC-09-00265, Rev. 0, Att. A.1, Page 107 DATE AND TIME OF RUN = MACCS2 11-NOV-09 19:34:05 VERSION 1.13.1: last revised 1/8/04, K. McFadden "ATMOS" DESCRIPTION = ATMOS INPUT FOR IPEC CALCULATIONS "EARLY" DESCRIPTION = EARLY.IN, IPEC INPUT FROM THE EVACUATION TIME ESTIMATES SOURCE TERM 6 OF 8:
LATE MEDIUM RESULTS FOR A SINGLE EMERGENCY RESPONSE COHORT WITHOUT ANY WEIGHTING FRACTIONS BEING APPLIED COHORT 1 = NO EVACUATION, RELOCATION MODELS APPLY EVERYWHE 11-NOV-09 19:34:05 PAGE 22 PROB QUANTILES PEAK PEAK PEAK NON-ZERO MEAN 50TH 90TH 95TH 99TH 99.5TH CONS PROB TRIAL HEALTH EFFECTS CASES ERL FAT/TOTAL 0-80.5 km 0.0000 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0 CAN FAT/TOTAL 0-80.5 km 1.0000 4.28E+02 3.61E+02 9.01E+02 1.07E+03 1.31E+03 1.43E+03 1.75E+03 1.00E-03 98 CAN FAT/TOTAL 0-16.1 km 1.0000 1.53E+02 1.31E+02 2.87E+02 3.11E+02 3.47E+02 3.63E+02 4.67E+02 1.14E-04 78 ERL FAT/TOTAL 0-16.1 km 0.0000 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0 AVERAGE INDIVIDUAL RISK ERL FAT/TOTAL 0-0.3 km 0.0000 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0 ERL FAT/TOTAL 0.3-1.6 km 0.0000 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0 ERL FAT/TOTAL 1.6-3.2 km 0.0000 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0 POPULATION DOSE (Sv)
L-EDEWBODY TOT LIF 0-80.5 km 1.0000 7.93E+03 7.10E+03 1.72E+04 2.11E+04 2.60E+04 2.84E+04 3.61E+04 1.00E-03 98 POPULATION WEIGHTED RISK ERL FAT/TOTAL 0-3.2 km 0.0000 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0 CAN FAT/TOTAL 0-16.1 km 1.0000 3.92E-04 3.48E-04 7.26E-04 7.78E-04 9.17E-04 9.83E-04 1.20E-03 1.14E-04 78
Calculation IP-CALC-09-00265, Rev. 0, Att. A.1, Page 108 DATE AND TIME OF RUN = MACCS2 11-NOV-09 19:34:05 VERSION 1.13.1: last revised 1/8/04, K. McFadden "ATMOS" DESCRIPTION = ATMOS INPUT FOR IPEC CALCULATIONS "EARLY" DESCRIPTION = EARLY.IN, IPEC INPUT FROM THE EVACUATION TIME ESTIMATES "CHRONC" DESCRIPTION = CHRONC.IN - IPEC, "New" COMIDA2-Based Food Model SOURCE TERM 6 OF 8:
LATE MEDIUM RESULTS FROM THE "CHRONC" MODULE ALONE COHORT 2 = CHRONC.IN - IPEC, "New" COMIDA2-Based Food Model 11-NOV-09 19:34:05 PAGE 23 PROB QUANTILES PEAK PEAK PEAK NON-ZERO MEAN 50TH 90TH 95TH 99TH 99.5TH CONS PROB TRIAL HEALTH EFFECTS CASES CAN FAT/TOTAL 0-80.5 km 1.0000 2.72E+03 1.29E+03 7.24E+03 9.47E+03 1.21E+04 1.32E+04 1.85E+04 3.71E-04 38 CAN FAT/TOTAL 0-16.1 km 1.0000 1.39E+02 1.18E+02 2.06E+02 2.18E+02 2.48E+02 2.62E+02 3.37E+02 9.80E-05 84 POPULATION DOSE (Sv)
L-EDEWBODY TOT LIF 0-80.5 km 1.0000 6.07E+04 2.95E+04 1.52E+05 2.16E+05 3.18E+05 3.36E+05 4.13E+05 3.71E-04 38 POPULATION WEIGHTED RISK CAN FAT/TOTAL 0-16.1 km 1.0000 2.96E-04 2.83E-04 4.49E-04 5.08E-04 5.59E-04 5.82E-04 6.95E-04 2.45E-04 84 L-EDEWBODY POP. DOSE (Sv) 0-80.5 km TOTAL LONG-TERM PATHWAYS DOSE 1.0000 6.07E+04 2.95E+04 1.52E+05 2.16E+05 3.18E+05 3.36E+05 4.13E+05 3.71E-04 38 LONG-TERM DIRECT EXPOSURE PATHWAYS 1.0000 5.99E+04 2.83E+04 1.52E+05 2.15E+05 3.16E+05 3.35E+05 4.13E+05 3.71E-04 38 TOTAL INGESTION PATHWAYS DOSE 1.0000 1.44E+02 1.14E+02 2.59E+02 3.03E+02 3.39E+02 3.56E+02 4.72E+02 8.56E-05 71 LONG-TERM GROUNDSHINE DOSE 1.0000 5.75E+04 2.57E+04 1.40E+05 2.02E+05 3.13E+05 3.29E+05 3.96E+05 3.71E-04 38 LONG-TERM RESUSPENSION DOSE 1.0000 2.35E+03 1.04E+03 6.53E+03 8.93E+03 1.16E+04 1.25E+04 1.66E+04 3.71E-04 38 WATER INGESTION DOSE 1.0000 6.41E+01 5.85E+01 1.04E+02 1.09E+02 1.22E+02 1.28E+02 1.96E+02 1.04E-05 146 POP.-DEPENDENT DECONTAMINATION DOSE 1.0000 7.22E+02 6.36E+02 1.20E+03 1.36E+03 1.81E+03 2.03E+03 2.42E+03 1.18E-03 100 FARM-DEPENDENT DECONTAMINATION DOSE 1.0000 4.65E-01 2.56E-01 9.89E-01 1.64E+00 2.66E+00 3.02E+00 4.08E+00 3.28E-05 145 INGESTION OF GRAINS 1.0000 2.87E+00 6.42E-01 1.00E+01 1.09E+01 1.32E+01 1.44E+01 2.16E+01 3.27E-05 150 INGESTION OF LEAF VEG 1.0000 5.49E+00 1.15E+00 1.54E+01 2.32E+01 5.04E+01 5.30E+01 6.16E+01 6.28E-04 67 INGESTION OF ROOT CROPS 1.0000 3.90E+00 8.85E-01 1.11E+01 1.23E+01 1.58E+01 1.76E+01 2.95E+01 3.27E-05 150 INGESTION OF FRUITS 1.0000 5.93E+00 1.60E+00 2.00E+01 2.15E+01 2.55E+01 2.75E+01 4.34E+01 3.27E-05 150 INGESTION OF LEGUMES 1.0000 3.58E+00 1.09E+00 1.06E+01 1.16E+01 1.44E+01 1.58E+01 2.53E+01 3.27E-05 150 INGESTION OF BEEF 1.0000 2.98E+01 1.25E+01 7.81E+01 9.51E+01 1.09E+02 1.13E+02 1.68E+02 5.66E-06 13 INGESTION OF MILK 1.0000 1.74E+01 7.61E+00 4.77E+01 6.05E+01 8.44E+01 9.46E+01 1.31E+02 4.57E-04 113 INGESTION OF POULTRY 1.0000 8.32E+00 2.87E+00 2.08E+01 2.88E+01 5.48E+01 6.34E+01 7.37E+01 6.28E-04 67 INGESTION OF OTHER MEAT CROPS 1.0000 2.79E+00 1.31E+00 7.66E+00 1.04E+01 1.35E+01 1.50E+01 2.07E+01 8.28E-04 97 ECONOMIC COST MEASURES ($) 0-80.5 km TOTAL ECONOMIC COSTS 1.0000 6.06E+09 4.48E+09 1.14E+10 1.74E+10 3.11E+10 3.19E+10 3.64E+10 1.00E-04 101 POP.-DEPENDENT COSTS 1.0000 5.96E+09 4.38E+09 1.12E+10 1.73E+10 3.11E+10 3.19E+10 3.64E+10 1.00E-04 101 FARM-DEPENDENT COSTS 1.0000 1.00E+08 3.51E+07 3.19E+08 3.88E+08 5.35E+08 5.73E+08 7.19E+08 6.28E-04 23 POP.-DEPENDENT DECONTAMINATION COST 1.0000 1.34E+09 1.01E+09 3.10E+09 4.44E+09 7.31E+09 7.52E+09 8.50E+09 2.49E-04 4 FARM-DEPENDENT DECONTAMINATION COST 1.0000 1.95E+06 6.85E+05 5.75E+06 7.91E+06 1.07E+07 1.13E+07 1.55E+07 6.97E-05 4 POP.-DEPENDENT INTERDICTION COST 1.0000 4.41E+09 3.19E+09 9.92E+09 1.47E+10 2.13E+10 2.21E+10 2.78E+10 1.00E-04 101 FARM-DEPENDENT INTERDICTION COST 1.0000 8.49E+07 2.07E+07 3.01E+08 3.55E+08 5.08E+08 5.43E+08 6.61E+08 6.28E-04 23 POP.-DEPENDENT CONDEMNATION COST 0.9917 2.06E+08 1.29E+08 4.79E+08 6.07E+08 1.03E+09 NOT-FOUND 1.05E+09 6.64E-03 77 FARM-DEPENDENT CONDEMNATION COST 0.9917 4.01E+04 9.54E+03 8.34E+04 9.20E+04 2.03E+05 2.36E+05 2.90E+05 1.95E-03 6 EMERGENCY PHASE COST 1.0000 1.60E+06 1.33E+06 3.05E+06 3.94E+06 5.25E+06 5.43E+06 8.05E+06 5.56E-06 146 INTERMEDIATE PHASE COST 0.0000 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0
Calculation IP-CALC-09-00265, Rev. 0, Att. A.1, Page 109 11-NOV-09 19:34:05 PAGE 24 PROB QUANTILES PEAK PEAK PEAK NON-ZERO MEAN 50TH 90TH 95TH 99TH 99.5TH CONS PROB TRIAL ECONOMIC COST MEASURES ($) 0-80.5 km MILK DISPOSAL COST 1.0000 5.55E+05 3.37E+04 1.87E+06 2.56E+06 3.59E+06 3.97E+06 5.60E+06 3.40E-05 150 CROP DISPOSAL COST 1.0000 1.27E+07 8.07E+06 3.04E+07 3.31E+07 4.05E+07 4.41E+07 5.71E+07 2.28E-04 23
Calculation IP-CALC-09-00265, Rev. 0, Att. A.1, Page 110 XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX
Calculation IP-CALC-09-00265, Rev. 0, Att. A.1, Page 111 DATE AND TIME OF RUN = MACCS2 11-NOV-09 19:34:05 VERSION 1.13.1: last revised 1/8/04, K. McFadden "ATMOS" DESCRIPTION = ATMOS INPUT FOR IPEC CALCULATIONS "EARLY" DESCRIPTION = EARLY.IN, IPEC INPUT FROM THE EVACUATION TIME ESTIMATES "CHRONC" DESCRIPTION = CHRONC.IN - IPEC, "New" COMIDA2-Based Food Model SOURCE TERM 7 OF 8:
LATE LOW OVERALL RESULTS OBTAINED BY COMBINING 1 EMERGENCY RESPONSE COHORTS FROM "EARLY" WITH THE WEIGHTING FRACTIONS BELOW APPLIED TO THEM:
FRACTION OF THE PEOPLE COHORT 1 = NO EVACUATION, RELOCATION MODELS APPLY EVERYWHE 1.000 AND THEN MERGING THE 1 RESULTS ABOVE WITH THE SINGLE SET OF RESULTS FROM "CHRONC" DESCRIBED BELOW:
COHORT 2 = CHRONC.IN - IPEC, "New" COMIDA2-Based Food Model RESULTS WHICH ARE PRODUCED ONLY BY "EARLY" OR ONLY BY "CHRONC" ARE PRESENTED IN LATER SECTIONS.
11-NOV-09 19:34:05 PAGE 25 PROB QUANTILES PEAK PEAK PEAK NON-ZERO MEAN 50TH 90TH 95TH 99TH 99.5TH CONS PROB TRIAL HEALTH EFFECTS CASES CAN FAT/TOTAL 0-80.5 km 1.0000 7.24E+02 5.15E+02 1.58E+03 2.13E+03 3.17E+03 3.46E+03 4.26E+03 1.00E-03 98 CAN FAT/TOTAL 0-16.1 km 1.0000 1.03E+02 9.87E+01 1.51E+02 1.81E+02 2.10E+02 2.17E+02 2.62E+02 5.26E-05 40 POPULATION DOSE (Sv)
L-EDEWBODY TOT LIF 0-80.5 km 1.0000 1.61E+04 1.14E+04 3.66E+04 4.87E+04 7.34E+04 7.94E+04 9.53E+04 1.00E-03 98 POPULATION WEIGHTED RISK CAN FAT/TOTAL 0-16.1 km 1.0000 2.53E-04 2.32E-04 3.80E-04 4.37E-04 5.19E-04 5.34E-04 6.40E-04 5.26E-05 40
Calculation IP-CALC-09-00265, Rev. 0, Att. A.1, Page 112 DATE AND TIME OF RUN = MACCS2 11-NOV-09 19:34:05 VERSION 1.13.1: last revised 1/8/04, K. McFadden "ATMOS" DESCRIPTION = ATMOS INPUT FOR IPEC CALCULATIONS "EARLY" DESCRIPTION = EARLY.IN, IPEC INPUT FROM THE EVACUATION TIME ESTIMATES SOURCE TERM 7 OF 8:
LATE LOW RESULTS FOR A SINGLE EMERGENCY RESPONSE COHORT WITHOUT ANY WEIGHTING FRACTIONS BEING APPLIED COHORT 1 = NO EVACUATION, RELOCATION MODELS APPLY EVERYWHE 11-NOV-09 19:34:05 PAGE 26 PROB QUANTILES PEAK PEAK PEAK NON-ZERO MEAN 50TH 90TH 95TH 99TH 99.5TH CONS PROB TRIAL HEALTH EFFECTS CASES ERL FAT/TOTAL 0-80.5 km 0.0000 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0 CAN FAT/TOTAL 0-80.5 km 1.0000 7.52E+01 7.04E+01 1.41E+02 1.80E+02 2.32E+02 2.50E+02 3.11E+02 1.00E-03 98 CAN FAT/TOTAL 0-16.1 km 1.0000 2.88E+01 2.70E+01 5.18E+01 6.05E+01 7.19E+01 7.33E+01 8.76E+01 8.36E-06 145 ERL FAT/TOTAL 0-16.1 km 0.0000 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0 AVERAGE INDIVIDUAL RISK ERL FAT/TOTAL 0-0.3 km 0.0000 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0 ERL FAT/TOTAL 0.3-1.6 km 0.0000 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0 ERL FAT/TOTAL 1.6-3.2 km 0.0000 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0 POPULATION DOSE (Sv)
L-EDEWBODY TOT LIF 0-80.5 km 1.0000 1.59E+03 1.21E+03 3.05E+03 3.60E+03 5.14E+03 5.60E+03 6.82E+03 1.00E-03 98 POPULATION WEIGHTED RISK ERL FAT/TOTAL 0-3.2 km 0.0000 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0 CAN FAT/TOTAL 0-16.1 km 1.0000 7.39E-05 6.96E-05 1.23E-04 1.43E-04 2.00E-04 2.02E-04 2.24E-04 8.36E-06 145
Calculation IP-CALC-09-00265, Rev. 0, Att. A.1, Page 113 DATE AND TIME OF RUN = MACCS2 11-NOV-09 19:34:05 VERSION 1.13.1: last revised 1/8/04, K. McFadden "ATMOS" DESCRIPTION = ATMOS INPUT FOR IPEC CALCULATIONS "EARLY" DESCRIPTION = EARLY.IN, IPEC INPUT FROM THE EVACUATION TIME ESTIMATES "CHRONC" DESCRIPTION = CHRONC.IN - IPEC, "New" COMIDA2-Based Food Model SOURCE TERM 7 OF 8:
LATE LOW RESULTS FROM THE "CHRONC" MODULE ALONE COHORT 2 = CHRONC.IN - IPEC, "New" COMIDA2-Based Food Model 11-NOV-09 19:34:05 PAGE 27 PROB QUANTILES PEAK PEAK PEAK NON-ZERO MEAN 50TH 90TH 95TH 99TH 99.5TH CONS PROB TRIAL HEALTH EFFECTS CASES CAN FAT/TOTAL 0-80.5 km 1.0000 6.48E+02 4.18E+02 1.42E+03 1.97E+03 3.13E+03 3.36E+03 3.95E+03 1.00E-03 98 CAN FAT/TOTAL 0-16.1 km 1.0000 7.41E+01 7.02E+01 1.06E+02 1.11E+02 1.25E+02 1.31E+02 2.13E+02 1.73E-06 54 POPULATION DOSE (Sv)
L-EDEWBODY TOT LIF 0-80.5 km 1.0000 1.45E+04 9.48E+03 3.36E+04 4.45E+04 6.14E+04 6.84E+04 8.85E+04 1.00E-03 98 POPULATION WEIGHTED RISK CAN FAT/TOTAL 0-16.1 km 1.0000 1.79E-04 1.59E-04 3.03E-04 3.15E-04 3.45E-04 3.58E-04 5.35E-04 1.73E-06 54 L-EDEWBODY POP. DOSE (Sv) 0-80.5 km TOTAL LONG-TERM PATHWAYS DOSE 1.0000 1.45E+04 9.48E+03 3.36E+04 4.45E+04 6.14E+04 6.84E+04 8.85E+04 1.00E-03 98 LONG-TERM DIRECT EXPOSURE PATHWAYS 1.0000 1.44E+04 9.44E+03 3.36E+04 4.45E+04 6.14E+04 6.84E+04 8.84E+04 1.00E-03 98 TOTAL INGESTION PATHWAYS DOSE 1.0000 8.45E+01 3.44E+01 2.49E+02 3.13E+02 4.10E+02 4.60E+02 5.03E+02 2.40E-03 23 LONG-TERM GROUNDSHINE DOSE 1.0000 1.38E+04 9.09E+03 3.21E+04 4.33E+04 6.07E+04 6.75E+04 8.45E+04 1.00E-03 98 LONG-TERM RESUSPENSION DOSE 1.0000 6.27E+02 3.88E+02 1.40E+03 1.94E+03 2.62E+03 2.97E+03 3.88E+03 1.00E-03 98 WATER INGESTION DOSE 1.0000 1.30E+01 1.11E+01 2.27E+01 2.63E+01 3.10E+01 3.18E+01 3.91E+01 1.04E-05 146 POP.-DEPENDENT DECONTAMINATION DOSE 1.0000 8.12E+01 7.49E+01 1.32E+02 1.55E+02 2.06E+02 2.15E+02 3.18E+02 1.24E-06 147 FARM-DEPENDENT DECONTAMINATION DOSE 1.0000 3.71E-02 2.74E-02 7.78E-02 1.04E-01 2.04E-01 2.16E-01 3.66E-01 1.59E-05 146 INGESTION OF GRAINS 1.0000 2.84E+00 3.95E-01 1.03E+01 1.24E+01 1.93E+01 2.09E+01 2.47E+01 6.28E-04 23 INGESTION OF LEAF VEG 1.0000 4.77E+00 6.70E-01 1.49E+01 2.22E+01 3.53E+01 4.07E+01 6.71E+01 2.29E-05 66 INGESTION OF ROOT CROPS 1.0000 3.84E+00 5.73E-01 1.29E+01 1.84E+01 2.85E+01 3.05E+01 3.27E+01 6.28E-04 23 INGESTION OF FRUITS 1.0000 5.59E+00 8.05E-01 2.05E+01 2.71E+01 3.50E+01 3.78E+01 4.77E+01 6.28E-04 23 INGESTION OF LEGUMES 1.0000 3.38E+00 6.11E-01 1.16E+01 1.53E+01 2.18E+01 2.33E+01 2.82E+01 6.28E-04 23 INGESTION OF BEEF 1.0000 2.59E+01 6.43E+00 8.47E+01 1.02E+02 1.14E+02 1.19E+02 1.88E+02 5.46E-06 13 INGESTION OF MILK 1.0000 1.65E+01 4.77E+00 5.38E+01 6.98E+01 8.47E+01 9.19E+01 1.30E+02 7.64E-06 12 INGESTION OF POULTRY 1.0000 7.13E+00 1.95E+00 2.34E+01 3.27E+01 5.13E+01 5.43E+01 8.74E+01 2.29E-05 66 INGESTION OF OTHER MEAT CROPS 1.0000 1.49E+00 4.70E-01 4.29E+00 5.86E+00 1.00E+01 1.05E+01 1.55E+01 2.29E-05 66 ECONOMIC COST MEASURES ($) 0-80.5 km TOTAL ECONOMIC COSTS 1.0000 6.59E+08 5.97E+08 1.06E+09 1.12E+09 1.28E+09 1.36E+09 2.07E+09 2.10E-05 40 POP.-DEPENDENT COSTS 1.0000 6.43E+08 5.78E+08 1.05E+09 1.12E+09 1.28E+09 1.36E+09 2.06E+09 2.10E-05 40 FARM-DEPENDENT COSTS 1.0000 1.57E+07 4.26E+06 5.36E+07 7.41E+07 1.07E+08 1.14E+08 1.65E+08 4.16E-05 4 POP.-DEPENDENT DECONTAMINATION COST 1.0000 1.58E+08 1.35E+08 3.06E+08 3.20E+08 3.55E+08 3.72E+08 5.26E+08 2.10E-05 40 FARM-DEPENDENT DECONTAMINATION COST 1.0000 1.90E+05 8.98E+04 4.15E+05 7.38E+05 1.12E+06 1.21E+06 1.42E+06 1.11E-03 123 POP.-DEPENDENT INTERDICTION COST 1.0000 4.76E+08 4.23E+08 9.73E+08 1.03E+09 1.12E+09 1.16E+09 1.52E+09 2.10E-05 40 FARM-DEPENDENT INTERDICTION COST 1.0000 1.36E+07 2.81E+06 5.04E+07 6.78E+07 1.04E+08 1.09E+08 1.51E+08 4.16E-05 4 POP.-DEPENDENT CONDEMNATION COST 0.8144 8.73E+06 3.75E+06 1.39E+07 1.72E+07 1.03E+08 1.06E+08 1.25E+08 6.75E-05 6 FARM-DEPENDENT CONDEMNATION COST 0.8629 5.27E+03 2.46E+03 8.12E+03 9.01E+03 7.20E+04 7.48E+04 7.73E+04 2.73E-03 6 EMERGENCY PHASE COST 0.9903 1.57E+05 1.07E+05 4.01E+05 5.24E+05 9.05E+05 1.02E+06 1.10E+06 1.83E-03 144 INTERMEDIATE PHASE COST 0.0000 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0
Calculation IP-CALC-09-00265, Rev. 0, Att. A.1, Page 114 11-NOV-09 19:34:05 PAGE 28 PROB QUANTILES PEAK PEAK PEAK NON-ZERO MEAN 50TH 90TH 95TH 99TH 99.5TH CONS PROB TRIAL ECONOMIC COST MEASURES ($) 0-80.5 km MILK DISPOSAL COST 1.0000 1.25E+05 8.03E+03 4.84E+05 6.43E+05 1.29E+06 1.55E+06 2.63E+06 2.57E-04 23 CROP DISPOSAL COST 1.0000 1.80E+06 1.03E+06 5.12E+06 6.06E+06 1.00E+07 1.03E+07 1.18E+07 8.03E-05 4
Calculation IP-CALC-09-00265, Rev. 0, Att. A.1, Page 115 XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX
Calculation IP-CALC-09-00265, Rev. 0, Att. A.1, Page 116 DATE AND TIME OF RUN = MACCS2 11-NOV-09 19:34:05 VERSION 1.13.1: last revised 1/8/04, K. McFadden "ATMOS" DESCRIPTION = ATMOS INPUT FOR IPEC CALCULATIONS "EARLY" DESCRIPTION = EARLY.IN, IPEC INPUT FROM THE EVACUATION TIME ESTIMATES "CHRONC" DESCRIPTION = CHRONC.IN - IPEC, "New" COMIDA2-Based Food Model SOURCE TERM 8 OF 8:
LATE LOWLOW OVERALL RESULTS OBTAINED BY COMBINING 1 EMERGENCY RESPONSE COHORTS FROM "EARLY" WITH THE WEIGHTING FRACTIONS BELOW APPLIED TO THEM:
FRACTION OF THE PEOPLE COHORT 1 = NO EVACUATION, RELOCATION MODELS APPLY EVERYWHE 1.000 AND THEN MERGING THE 1 RESULTS ABOVE WITH THE SINGLE SET OF RESULTS FROM "CHRONC" DESCRIBED BELOW:
COHORT 2 = CHRONC.IN - IPEC, "New" COMIDA2-Based Food Model RESULTS WHICH ARE PRODUCED ONLY BY "EARLY" OR ONLY BY "CHRONC" ARE PRESENTED IN LATER SECTIONS.
11-NOV-09 19:34:05 PAGE 29 PROB QUANTILES PEAK PEAK PEAK NON-ZERO MEAN 50TH 90TH 95TH 99TH 99.5TH CONS PROB TRIAL HEALTH EFFECTS CASES CAN FAT/TOTAL 0-80.5 km 1.0000 6.16E+02 4.08E+02 1.32E+03 1.79E+03 2.54E+03 2.87E+03 3.61E+03 1.00E-03 98 CAN FAT/TOTAL 0-16.1 km 1.0000 9.13E+01 8.58E+01 1.30E+02 1.49E+02 2.00E+02 2.03E+02 2.43E+02 1.73E-06 54 POPULATION DOSE (Sv)
L-EDEWBODY TOT LIF 0-80.5 km 1.0000 1.38E+04 1.00E+04 3.19E+04 4.19E+04 5.99E+04 6.67E+04 8.10E+04 1.00E-03 98 POPULATION WEIGHTED RISK CAN FAT/TOTAL 0-16.1 km 1.0000 2.25E-04 2.10E-04 3.45E-04 3.85E-04 4.99E-04 5.08E-04 6.16E-04 1.73E-06 54
Calculation IP-CALC-09-00265, Rev. 0, Att. A.1, Page 117 DATE AND TIME OF RUN = MACCS2 11-NOV-09 19:34:05 VERSION 1.13.1: last revised 1/8/04, K. McFadden "ATMOS" DESCRIPTION = ATMOS INPUT FOR IPEC CALCULATIONS "EARLY" DESCRIPTION = EARLY.IN, IPEC INPUT FROM THE EVACUATION TIME ESTIMATES SOURCE TERM 8 OF 8:
LATE LOWLOW RESULTS FOR A SINGLE EMERGENCY RESPONSE COHORT WITHOUT ANY WEIGHTING FRACTIONS BEING APPLIED COHORT 1 = NO EVACUATION, RELOCATION MODELS APPLY EVERYWHE 11-NOV-09 19:34:05 PAGE 30 PROB QUANTILES PEAK PEAK PEAK NON-ZERO MEAN 50TH 90TH 95TH 99TH 99.5TH CONS PROB TRIAL HEALTH EFFECTS CASES ERL FAT/TOTAL 0-80.5 km 0.0000 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0 CAN FAT/TOTAL 0-80.5 km 1.0000 5.01E+01 4.42E+01 9.84E+01 1.10E+02 1.41E+02 1.57E+02 2.07E+02 1.00E-03 98 CAN FAT/TOTAL 0-16.1 km 1.0000 1.90E+01 1.66E+01 3.31E+01 3.77E+01 5.01E+01 5.08E+01 6.00E+01 1.24E-06 147 ERL FAT/TOTAL 0-16.1 km 0.0000 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0 AVERAGE INDIVIDUAL RISK ERL FAT/TOTAL 0-0.3 km 0.0000 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0 ERL FAT/TOTAL 0.3-1.6 km 0.0000 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0 ERL FAT/TOTAL 1.6-3.2 km 0.0000 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0 POPULATION DOSE (Sv)
L-EDEWBODY TOT LIF 0-80.5 km 1.0000 1.10E+03 1.01E+03 2.10E+03 2.68E+03 3.52E+03 3.83E+03 4.66E+03 1.00E-03 98 POPULATION WEIGHTED RISK ERL FAT/TOTAL 0-3.2 km 0.0000 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0 CAN FAT/TOTAL 0-16.1 km 1.0000 4.86E-05 4.37E-05 9.12E-05 1.02E-04 1.08E-04 1.11E-04 1.54E-04 1.24E-06 147
Calculation IP-CALC-09-00265, Rev. 0, Att. A.1, Page 118 DATE AND TIME OF RUN = MACCS2 11-NOV-09 19:34:05 VERSION 1.13.1: last revised 1/8/04, K. McFadden "ATMOS" DESCRIPTION = ATMOS INPUT FOR IPEC CALCULATIONS "EARLY" DESCRIPTION = EARLY.IN, IPEC INPUT FROM THE EVACUATION TIME ESTIMATES "CHRONC" DESCRIPTION = CHRONC.IN - IPEC, "New" COMIDA2-Based Food Model SOURCE TERM 8 OF 8:
LATE LOWLOW RESULTS FROM THE "CHRONC" MODULE ALONE COHORT 2 = CHRONC.IN - IPEC, "New" COMIDA2-Based Food Model 11-NOV-09 19:34:05 PAGE 31 PROB QUANTILES PEAK PEAK PEAK NON-ZERO MEAN 50TH 90TH 95TH 99TH 99.5TH CONS PROB TRIAL HEALTH EFFECTS CASES CAN FAT/TOTAL 0-80.5 km 1.0000 5.66E+02 3.61E+02 1.26E+03 1.72E+03 2.51E+03 2.84E+03 3.40E+03 1.00E-03 98 CAN FAT/TOTAL 0-16.1 km 1.0000 7.23E+01 6.70E+01 1.06E+02 1.11E+02 1.25E+02 1.31E+02 2.25E+02 1.73E-06 54 POPULATION DOSE (Sv)
L-EDEWBODY TOT LIF 0-80.5 km 1.0000 1.27E+04 8.44E+03 3.03E+04 4.08E+04 5.98E+04 6.66E+04 7.63E+04 1.00E-03 98 POPULATION WEIGHTED RISK CAN FAT/TOTAL 0-16.1 km 1.0000 1.76E-04 1.57E-04 2.95E-04 3.11E-04 3.42E-04 3.56E-04 5.68E-04 1.73E-06 54 L-EDEWBODY POP. DOSE (Sv) 0-80.5 km TOTAL LONG-TERM PATHWAYS DOSE 1.0000 1.27E+04 8.44E+03 3.03E+04 4.08E+04 5.98E+04 6.66E+04 7.63E+04 1.00E-03 98 LONG-TERM DIRECT EXPOSURE PATHWAYS 1.0000 1.26E+04 8.36E+03 3.02E+04 4.07E+04 5.98E+04 6.66E+04 7.62E+04 1.00E-03 98 TOTAL INGESTION PATHWAYS DOSE 1.0000 8.17E+01 3.18E+01 2.29E+02 3.11E+02 4.73E+02 5.15E+02 5.84E+02 6.28E-04 23 LONG-TERM GROUNDSHINE DOSE 1.0000 1.22E+04 8.20E+03 2.99E+04 3.92E+04 5.87E+04 6.59E+04 7.41E+04 1.00E-03 98 LONG-TERM RESUSPENSION DOSE 1.0000 3.46E+02 2.29E+02 7.84E+02 1.00E+03 1.52E+03 1.82E+03 2.12E+03 1.00E-03 98 WATER INGESTION DOSE 1.0000 1.08E+01 9.54E+00 1.97E+01 2.21E+01 2.83E+01 3.01E+01 3.28E+01 1.04E-05 146 POP.-DEPENDENT DECONTAMINATION DOSE 1.0000 6.43E+01 5.93E+01 1.17E+02 1.39E+02 2.00E+02 2.04E+02 2.51E+02 1.24E-06 147 FARM-DEPENDENT DECONTAMINATION DOSE 1.0000 2.87E-02 2.22E-02 5.87E-02 7.41E-02 1.34E-01 1.87E-01 2.56E-01 1.59E-05 146 INGESTION OF GRAINS 1.0000 2.84E+00 4.01E-01 1.00E+01 1.27E+01 2.05E+01 2.19E+01 2.65E+01 6.28E-04 23 INGESTION OF LEAF VEG 1.0000 4.74E+00 6.38E-01 1.57E+01 2.23E+01 3.27E+01 3.66E+01 7.05E+01 2.85E-05 75 INGESTION OF ROOT CROPS 1.0000 3.78E+00 5.64E-01 1.25E+01 1.81E+01 2.85E+01 3.09E+01 3.48E+01 6.28E-04 23 INGESTION OF FRUITS 1.0000 5.56E+00 8.04E-01 1.79E+01 2.68E+01 3.95E+01 4.53E+01 5.11E+01 6.28E-04 23 INGESTION OF LEGUMES 1.0000 3.27E+00 5.21E-01 1.10E+01 1.51E+01 2.22E+01 2.39E+01 2.98E+01 6.28E-04 23 INGESTION OF BEEF 1.0000 2.54E+01 6.50E+00 8.09E+01 1.07E+02 1.53E+02 1.79E+02 2.08E+02 6.28E-04 23 INGESTION OF MILK 1.0000 1.65E+01 4.60E+00 5.26E+01 6.75E+01 1.01E+02 1.05E+02 1.46E+02 5.46E-06 13 INGESTION OF POULTRY 1.0000 7.37E+00 1.91E+00 2.55E+01 3.42E+01 5.09E+01 5.54E+01 9.67E+01 2.85E-05 75 INGESTION OF OTHER MEAT CROPS 1.0000 1.41E+00 4.56E-01 4.46E+00 5.79E+00 7.80E+00 8.48E+00 1.61E+01 2.85E-05 75 ECONOMIC COST MEASURES ($) 0-80.5 km TOTAL ECONOMIC COSTS 1.0000 5.62E+08 5.20E+08 1.02E+09 1.07E+09 1.18E+09 1.23E+09 1.75E+09 2.10E-05 40 POP.-DEPENDENT COSTS 1.0000 5.51E+08 4.91E+08 1.02E+09 1.06E+09 1.18E+09 1.23E+09 1.74E+09 2.10E-05 40 FARM-DEPENDENT COSTS 1.0000 1.15E+07 3.18E+06 3.59E+07 5.42E+07 9.60E+07 1.05E+08 1.49E+08 6.29E-05 5 POP.-DEPENDENT DECONTAMINATION COST 1.0000 1.36E+08 1.19E+08 2.61E+08 3.05E+08 3.32E+08 3.45E+08 4.37E+08 6.26E-05 26 FARM-DEPENDENT DECONTAMINATION COST 1.0000 1.61E+05 8.03E+04 3.69E+05 6.35E+05 1.04E+06 1.11E+06 1.25E+06 1.13E-03 26 POP.-DEPENDENT INTERDICTION COST 1.0000 4.09E+08 3.64E+08 7.64E+08 8.79E+08 1.04E+09 1.07E+09 1.31E+09 2.10E-05 85 FARM-DEPENDENT INTERDICTION COST 1.0000 1.00E+07 1.94E+06 3.48E+07 5.24E+07 8.07E+07 1.02E+08 1.37E+08 6.29E-05 5 POP.-DEPENDENT CONDEMNATION COST 0.8040 5.25E+06 3.43E+06 1.10E+07 1.20E+07 1.46E+07 1.59E+07 1.25E+08 1.64E-05 6 FARM-DEPENDENT CONDEMNATION COST 0.7189 1.98E+03 2.03E+03 2.74E+03 7.70E+03 NOT-FOUND NOT-FOUND 8.49E+03 4.80E-02 1 EMERGENCY PHASE COST 0.9902 7.17E+04 1.51E+04 1.95E+05 3.18E+05 3.95E+05 4.34E+05 4.97E+05 1.83E-03 20 INTERMEDIATE PHASE COST 0.0000 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0
Calculation IP-CALC-09-00265, Rev. 0, Att. A.1, Page 119 11-NOV-09 19:34:05 PAGE 32 PROB QUANTILES PEAK PEAK PEAK NON-ZERO MEAN 50TH 90TH 95TH 99TH 99.5TH CONS PROB TRIAL ECONOMIC COST MEASURES ($) 0-80.5 km MILK DISPOSAL COST 1.0000 9.39E+04 5.58E+03 3.52E+05 5.31E+05 1.13E+06 1.30E+06 2.26E+06 6.28E-04 137 CROP DISPOSAL COST 1.0000 1.26E+06 6.64E+05 3.17E+06 4.08E+06 5.88E+06 6.55E+06 1.18E+07 3.87E-05 62 Successful completion of MACCS2 was achieved!
This job required a total of 56.508 CPU seconds Input processing required 0.547 CPU seconds Simulation required 54.977 CPU seconds Output processing required 0.984 CPU seconds
ENTERGY - Calculation No. IP-CALC-09-00265, Rev. 0 MACCS2 Models for IPEC Attachment A.2 IP3 MACCS2 Input and Output File
Calculation IP-CALC-09-00265, Rev. 0, Att. A.2, Page 1 MACCS2 12-NOV-09 13:50:14 VERSION 1.13.1: last revised 1/8/04, K. McFadden P1: ATMOS USER INPUT (UNIT 24) = atmbi3NS.INP P2: EARLY USER INPUT (UNIT 25) = earbi-noE.INP P3: CHRONC USER INPUT (UNIT 26) = chrbiEC.INP P4: METEOROLOGY DATA (UNIT 28) = meti00.INP P5: SITE DATA INPUT (UNIT 29) = siteiEC.INP P6: LIST OUTPUT (UNIT 06) = conbi3NS-noE-NmetEC.OUT USER INPUT IS READ FROM UNIT 24 RECORD IDENTIFIER FIELDS 11 CHARACTERS LONG ARE EXPECTED.
THE FIRST 100 COLUMNS OF EACH INPUT RECORD ARE PROCESSED.
THE MAXIMUM NUMBER OF IDENTIFIER RECORDS THAT MAY BE SAVED AS THE BASE CASE IS 1000.
RECORD NUMBER RECORD
- GENERAL DESCRIPTIVE TITLE DESCRIBING THIS "ATMOS" INPUT 1 RIATNAM1001 'ATMOS INPUT FOR IPEC CALCULATIONS'
- GEOMETRY DATA BLOCK, LOADED BY INPGEO, STORED IN /GEOM/
- NUMBER OF RADIAL SPATIAL ELEMENTS 2 GENUMRAD001 15 3 GESPAEND001 0.32 1.61 3.22 4.83 6.44 4 GESPAEND002 8.05 9.66 11.27 12.87 14.48 5 GESPAEND003 16.09 32.19 48.28 64.37 80.47
- NUCLIDE DATA BLOCK, LOADED BY INPISO, STORED IN /ISOGRP/, /ISONAM/
- Number of pseudo-stable nuclides (used to truncate the decay chains) 6 ISNUMSTB001 27
- List of pseudo-stable nuclides 7 ISNAMSTB001 I-129 (daughter of Te-129 and Te-129m) 8 ISNAMSTB002 Xe-131m (daughter of I-131) 9 ISNAMSTB003 Xe-133m (daughter of I-133) 10 ISNAMSTB004 Xe-135m (daughter of I-135) 11 ISNAMSTB005 Cs-135 (daughter of Xe-135 and Xe-135m) 12 ISNAMSTB006 Sm-147 (daughter of Pm-147) 13 ISNAMSTB007 U-234 (daughter of Pu-238) 14 ISNAMSTB008 U-235 (daughter of Pu-239) 15 ISNAMSTB009 U-236 (daughter of Pu-240) 16 ISNAMSTB010 U-237 (daughter of Pu-241) 17 ISNAMSTB011 Np-237 (daughter of Am-241) 18 ISNAMSTB012 Rb-87 (daughter of Kr-87) 19 ISNAMSTB013 Ba-137m (daughter of Cs-137) 20 ISNAMSTB014 Rb-88 (daughter of Kr-88) 21 ISNAMSTB015 Y-91m (daughter of Sr-91) 22 ISNAMSTB016 Zr-93 (daughter of Y-93) 23 ISNAMSTB017 Nb-93m (daughter of Zr-93)
Calculation IP-CALC-09-00265, Rev. 0, Att. A.2, Page 2 24 ISNAMSTB018 Nb-95m (daughter of Zr-95) 25 ISNAMSTB019 Nb-97 (daughter of Zr-97 and Nb-97m) 26 ISNAMSTB020 Nb-97m (daughter of Zr-97) 27 ISNAMSTB021 Tc-99 (daughter of Mo-99) 28 ISNAMSTB022 Rh-103m (daughter of Ru-103) 29 ISNAMSTB023 Rh-106 (daughter of Ru-106) 30 ISNAMSTB024 Te-131 (daughter of Te-131m) 31 ISNAMSTB025 Pr-144 (daughter of Ce-144 and Pr-144m) 32 ISNAMSTB026 Pr-144m (daughter of Ce-144) 33 ISNAMSTB027 Pm-147 (daughter of Nd-147)
- Number of radioactive nuclides to be considered 34 ISNUMISO001 60
- NUMBER OF NUCLIDE GROUPS 35 ISMAXGRP001 9
- WET AND DRY DEPOSITION FLAGS FOR EACH NUCLIDE GROUP
- WETDEP DRYDEP 36 ISDEPFLA001 .FALSE. .FALSE.
37 ISDEPFLA002 .TRUE. .TRUE.
38 ISDEPFLA003 .TRUE. .TRUE.
39 ISDEPFLA004 .TRUE. .TRUE.
40 ISDEPFLA005 .TRUE. .TRUE.
41 ISDEPFLA006 .TRUE. .TRUE.
42 ISDEPFLA007 .TRUE. .TRUE.
43 ISDEPFLA008 .TRUE. .TRUE.
44 ISDEPFLA009 .TRUE. .TRUE.
- NUCLIDE GROUP DATA FOR 9 NUCLIDE GROUPS
- NUCNAM IGROUP 45 ISOTPGRP001 Co-58 6 46 ISOTPGRP002 Co-60 6 47 ISOTPGRP003 Kr-85 1 48 ISOTPGRP004 Kr-85m 1 49 ISOTPGRP005 Kr-87 1 50 ISOTPGRP006 Kr-88 1 51 ISOTPGRP007 Rb-86 3 52 ISOTPGRP008 Sr-89 5 53 ISOTPGRP009 Sr-90 5 54 ISOTPGRP010 Sr-91 5 55 ISOTPGRP011 Sr-92 5 56 ISOTPGRP012 Y-90 7 57 ISOTPGRP013 Y-91 7 58 ISOTPGRP014 Y-92 7 59 ISOTPGRP015 Y-93 7 60 ISOTPGRP016 Zr-95 7 61 ISOTPGRP017 Zr-97 7 62 ISOTPGRP018 Nb-95 7 63 ISOTPGRP019 Mo-99 6 64 ISOTPGRP020 Tc-99m 6 65 ISOTPGRP021 Ru-103 6 66 ISOTPGRP022 Ru-105 6
Calculation IP-CALC-09-00265, Rev. 0, Att. A.2, Page 3 67 ISOTPGRP023 Ru-106 6 68 ISOTPGRP024 Rh-105 6 69 ISOTPGRP025 Sb-127 4 70 ISOTPGRP026 Sb-129 4 71 ISOTPGRP027 Te-127 4 72 ISOTPGRP028 Te-127m 4 73 ISOTPGRP029 Te-129 4 74 ISOTPGRP030 Te-129m 4 75 ISOTPGRP031 Te-131m 4 76 ISOTPGRP032 Te-132 4 77 ISOTPGRP033 I-131 2 78 ISOTPGRP034 I-132 2 79 ISOTPGRP035 I-133 2 80 ISOTPGRP036 I-134 2 81 ISOTPGRP037 I-135 2 82 ISOTPGRP038 Xe-133 1 83 ISOTPGRP039 Xe-135 1 84 ISOTPGRP040 Cs-134 3 85 ISOTPGRP041 Cs-136 3 86 ISOTPGRP042 Cs-137 3 87 ISOTPGRP043 Ba-139 9 88 ISOTPGRP044 Ba-140 9 89 ISOTPGRP045 La-140 7 90 ISOTPGRP046 La-141 7 91 ISOTPGRP047 La-142 7 92 ISOTPGRP048 Ce-141 8 93 ISOTPGRP049 Ce-143 8 94 ISOTPGRP050 Ce-144 8 95 ISOTPGRP051 Pr-143 7 96 ISOTPGRP052 Nd-147 7 97 ISOTPGRP053 Np-239 8 98 ISOTPGRP054 Pu-238 8 99 ISOTPGRP055 Pu-239 8 100 ISOTPGRP056 Pu-240 8 101 ISOTPGRP057 Pu-241 8 102 ISOTPGRP058 Am-241 7 103 ISOTPGRP059 Cm-242 7 104 ISOTPGRP060 Cm-244 7
- WET DEPOSITION DATA BLOCK, LOADED BY INPWET, STORED IN /WETCON/
- WASHOUT COEFFICIENT NUMBER ONE, LINEAR FACTOR 105 WDCWASH1001 9.5E-5 (JON HELTON AFTER JONES, 1986)
- WASHOUT COEFFICIENT NUMBER TWO, EXPONENTIAL FACTOR 106 WDCWASH2001 0.8 (JON HELTON AFTER JONES, 1986)
- DRY DEPOSITION DATA BLOCK, LOADED BY INPDRY, STORED IN /DRYCON/
- NUMBER OF PARTICLE SIZE GROUPS 107 DDNPSGRP001 1
- DEPOSITION VELOCITY OF EACH PARTICLE SIZE GROUP (M/S) 108 DDVDEPOS001 0.01 (VALUE SELECTED BY S. ACHARYA, NRC)
Calculation IP-CALC-09-00265, Rev. 0, Att. A.2, Page 4
- DISPERSION PARAMETER DATA BLOCK, LOADED BY INPDIS, STORED IN /DISPY/, /DISPZ/
- # of distances in plume-size tables--which can be used as an alternative to the power-law model:
- (to utilize the power-law model, set NUM_DIST to zero or delete the following data card) 109 NUM_DIST001 0
- SIGMA = A
- X ** B
- Tadmor and Gur Parameterization for Distance Range 0.5 to 5.0 km
- as taken from Atmospheric Motion and Air Pollution (Dobbins 1979).
- P-G CLASS: A B C D E F 110 DPCYSIGA001 0.3658 0.2751 0.2089 0.1474 0.1046 0.0722 111 DPCYSIGB001 0.9031 0.9031 0.9031 0.9031 0.9031 0.9031 112 DPCZSIGA001 2.5E-4 1.9E-3 0.2 0.3 0.4 0.2 113 DPCZSIGB001 2.125 1.6021 0.8543 0.6532 0.6021 0.6020
- LINEAR SCALING FACTOR FOR SIGMA-Y FUNCTION, NORMALLY 1 114 DPYSCALE001 1.
- LINEAR SCALING FACTOR FOR SIGMA-Z FUNCTION,
- NORMALLY USED FOR SURFACE ROUGHNESS LENGTH CORRECTION.
- EXPANSION FACTOR DATA BLOCK, LOADED BY INPEXP, STORED IN /EXPAND/
- TIME BASE FOR EXPANSION FACTOR (SECONDS) 116 PMTIMBAS001 600. (10 MINUTES)
- BREAK POINT FOR FORMULA CHANGE (SECONDS) 117 PMBRKPNT001 3600. (1 HOUR)
- EXPONENTIAL EXPANSION FACTOR NUMBER 1 118 PMXPFAC1001 0.2
- EXPONENTIAL EXPANSION FACTOR NUMBER 2 119 PMXPFAC2001 0.25
- PLUME RISE DATA BLOCK, LOADED BY INPLRS, STORED IN /PLUMRS/
- SCALING FACTOR FOR THE CRITICAL WIND SPEED FOR ENTRAINMENT OF A BOUYANT PLUME
- (USED BY FUNCTION CAUGHT) 120 PRSCLCRW001 1.
- SCALING FACTOR FOR THE A-D STABILITY PLUME RISE FORMULA
- (USED BY FUNCTION PLMRIS) 121 PRSCLADP001 1.
- SCALING FACTOR FOR THE E-F STABILITY PLUME RISE FORMULA
- (USED BY FUNCTION PLMRIS)
Calculation IP-CALC-09-00265, Rev. 0, Att. A.2, Page 5 122 PRSCLEFP001 1.
- RELEASE DATA BLOCK, LOADED BY INPREL, STORED IN /ATNAM2/, /MULREL/
- RELEASE DATA BLOCK ************
- SOURCE TERM NUMBER 1 OF 8 123 RDATNAM2001 'NCF'
- TIME AFTER ACCIDENT INITIATION WHEN THE ACCIDENT REACHES GENERAL EMERGENCY
- CONDITIONS (AS DEFINED IN NUREG-0654), OR WHEN PLANT PERSONNEL CAN RELIABLY
- PREDICT THAT GENERAL EMERGENCY CONDITIONS WILL BE ATTAINED 124 RDOALARM001 1.26E+04
- NUMBER OF PLUME SEGMENTS THAT ARE RELEASED 125 RDNUMREL001 1
- SELECTION OF RISK DOMINANT PLUME 126 RDMAXRIS001 1
- REFERENCE TIME FOR DISPERSION AND RADIOACTIVE DECAY 127 RDREFTIM001 0.5
- HEAT CONTENT OF THE RELEASE SEGMENTS (W)
- A VALUE SPECIFIED FOR EACH OF THE RELEASE SEGMENTS 128 RDPLHEAT001 9.20E+05
- HEIGHT OF THE PLUME SEGMENTS AT RELEASE (M)
- A VALUE SPECIFIED FOR EACH OF THE RELEASE SEGMENTS 129 RDPLHITE001 30.
- DURATION OF THE PLUME SEGMENTS (S)
- A VALUE SPECIFIED FOR EACH OF THE RELEASE SEGMENTS 130 RDPLUDUR001 8.64E+04
- TIME OF RELEASE FOR EACH PLUME (S AFTER SCRAM)
- A VALUE SPECIFIED FOR EACH OF THE RELEASE SEGMENTS 131 RDPDELAY001 0.00E+00
- Initial value of sigma-y for each plume--Note: values required for each plume 132 SIGYINIT001 9.9 (initial sigma-y = W/4.3 = 42.5/4.3)
- Initial value of sigma-z for each plume--Note: values required for each plume 133 SIGZINIT001 31.1 (initial sigma-z = H/2.15 = 66.8/2.15)
- Building height (meters)--Note: values required for each plume 134 WEBUILDH001 66.8
- PARTICLE SIZE DISTRIBUTION OF EACH NUCLIDE GROUP
Calculation IP-CALC-09-00265, Rev. 0, Att. A.2, Page 6
- YOU MUST SPECIFY A COLUMN OF DATA FOR EACH OF THE PARTICLE SIZE GROUPS 135 RDPSDIST001 1.
136 RDPSDIST002 1.
137 RDPSDIST003 1.
138 RDPSDIST004 1.
139 RDPSDIST005 1.
140 RDPSDIST006 1.
141 RDPSDIST007 1.
142 RDPSDIST008 1.
143 RDPSDIST009 1.
- NUCNAM CORINV (Bq) 144 RDCORINV001 Co-58 3.04E+16 145 RDCORINV002 Co-60 2.32E+16 146 RDCORINV003 Kr-85 3.87E+16 147 RDCORINV004 Kr-85m 8.52E+17 148 RDCORINV005 Kr-87 1.64E+18 149 RDCORINV006 Kr-88 2.30E+18 150 RDCORINV007 Rb-86 8.24E+15 151 RDCORINV008 Sr-89 3.09E+18 152 RDCORINV009 Sr-90 3.07E+17 153 RDCORINV010 Sr-91 3.87E+18 154 RDCORINV011 Sr-92 4.19E+18 155 RDCORINV012 Y-90 3.20E+17 156 RDCORINV013 Y-91 3.98E+18 157 RDCORINV014 Y-92 4.22E+18 158 RDCORINV015 Y-93 4.85E+18 159 RDCORINV016 Zr-95 5.38E+18 160 RDCORINV017 Zr-97 5.41E+18 161 RDCORINV018 Nb-95 5.45E+18 162 RDCORINV019 Mo-99 6.11E+18 163 RDCORINV020 Tc-99m 5.34E+18 164 RDCORINV021 Ru-103 4.85E+18 165 RDCORINV022 Ru-105 3.34E+18 166 RDCORINV023 Ru-106 1.69E+18 167 RDCORINV024 Rh-105 3.08E+18 168 RDCORINV025 Sb-127 3.45E+17 169 RDCORINV026 Sb-129 1.04E+18 170 RDCORINV027 Te-127 3.43E+17 171 RDCORINV028 Te-127m 4.47E+16 172 RDCORINV029 Te-129 1.02E+18 173 RDCORINV030 Te-129m 1.49E+17 174 RDCORINV031 Te-131m 4.64E+17 175 RDCORINV032 Te-132 4.54E+18 176 RDCORINV033 I-131 3.18E+18 177 RDCORINV034 I-132 4.64E+18 178 RDCORINV035 I-133 6.56E+18 179 RDCORINV036 I-134 7.19E+18 180 RDCORINV037 I-135 6.14E+18 181 RDCORINV038 Xe-133 6.25E+18 182 RDCORINV039 Xe-135 1.67E+18 183 RDCORINV040 Cs-134 7.16E+17 184 RDCORINV041 Cs-136 2.08E+17 185 RDCORINV042 Cs-137 4.15E+17 186 RDCORINV043 Ba-139 5.86E+18 187 RDCORINV044 Ba-140 5.58E+18
Calculation IP-CALC-09-00265, Rev. 0, Att. A.2, Page 7 188 RDCORINV045 La-140 5.76E+18 189 RDCORINV046 La-141 5.34E+18 190 RDCORINV047 La-142 5.17E+18 191 RDCORINV048 Ce-141 5.31E+18 192 RDCORINV049 Ce-143 4.99E+18 193 RDCORINV050 Ce-144 4.19E+18 194 RDCORINV051 Pr-143 4.78E+18 195 RDCORINV052 Nd-147 2.12E+18 196 RDCORINV053 Np-239 6.53E+19 197 RDCORINV054 Pu-238 1.43E+16 198 RDCORINV055 Pu-239 1.22E+15 199 RDCORINV056 Pu-240 1.82E+15 200 RDCORINV057 Pu-241 4.08E+17 201 RDCORINV058 Am-241 5.03E+14 202 RDCORINV059 Cm-242 1.21E+17 203 RDCORINV060 Cm-244 1.29E+16
- SCALING FACTOR TO ADJUST THE CORE INVENTORY FOR POWER LEVEL 204 RDCORSCA001 1.0 205 RDAPLFRC001 PARENT (apply rel fracs the same as prior versions)
- RELEASE FRACTIONS FOR ISOTOPE GROUPS IN RELEASE
- ISOTOPE GROUPS:
- Xe/Kr I Cs Te Sr Ru La Ce Ba 206 RDRELFRC001 9.6E-05 6.5E-06 2.7E-06 2.1E-06 6.1E-08 5.2E-07 3.3E-09 2.7E-08 1.8E-07
- OUTPUT CONTROL DATA BLOCK, LOADED BY INPOPT, STORED IN /STOPME/, /ATMOPT/
- FLAG TO INDICATE THAT THIS IS THE LAST PROGRAM IN THE SERIES TO BE RUN 207 OCENDAT1001 .FALSE. (SET THIS VALUE TO .TRUE. TO SKIP EARLY AND CHRONC) 208 OCIDEBUG001 0
- NAME OF THE NUCLIDE TO BE LISTED ON THE DISPERSION LISTINGS
- OCNUCOUT001 Cs-137
- NUM0 209 TYPE0NUMBER 0
- INDREL INDRAD
- TYPE0OUT001 1 9
- TYPE0OUT002 1 10 CCDF
- METEOROLOGICAL SAMPLING DATA BLOCK
- METEOROLOGICAL SAMPLING OPTION CODE:
- METCOD = 1, USER SPECIFIED DAY AND HOUR IN THE YEAR (FROM MET FILE),
- 2, WEATHER CATEGORY BIN SAMPLING,
- 3, 120 HOURS OF WEATHER SPECIFIED ON THE ATMOS USER INPUT FILE,
Calculation IP-CALC-09-00265, Rev. 0, Att. A.2, Page 8
- 4, CONSTANT MET (BOUNDARY WEATHER USED FROM THE START),
- 5, STRATIFIED RANDOM SAMPLES FOR EACH DAY OF THE YEAR.
210 M1METCOD001 2
- LAST SPATIAL INTERVAL FOR MEASURED WEATHER 211 M2LIMSPA001 15
- BOUNDARY WEATHER MIXING LAYER HEIGHT 212 M2BNDMXH001 1000. (METERS)
- BOUNDARY WEATHER STABILITY CLASS INDEX 213 M2IBDSTB001 4 (D-STABILITY)
- BOUNDARY WEATHER RAIN RATE 214 M2BNDRAN001 0. (MM/HR)
- BOUNDARY WEATHER WIND SPEED 215 M2BNDWND001 5. (M/S)
- NUMBER OF RAIN DISTANCE INTERVALS FOR BINNING 216 M4NRNINT001 6
- ENDPOINTS OF THE RAIN DISTANCE INTERVALS (KILOMETERS)
- NOTE: THESE MUST BE CHOSEN TO MATCH THE SPATIAL ENDPOINT DISTANCES
- SPECIFIED FOR THE ARRAY SPAEND (10 % ERROR IS ALLOWED).
- 2.0 4.0 7 10.0 20.0 40.0 MILES 217 M4RNDSTS001 3.23 6.45 11.29 16.13 32.26 64.52 KM
- NUMBER OF RAIN INTENSITIY BREAKPOINTS 218 M4NRINTN001 3
- RAIN INTENSITY BREAKPOINTS FOR WEATHER BINNING (MILLIMETERS PER HOUR) 219 M4RNRATE001 2. 4. 6.
- NUMBER OF SAMPLES PER BIN 220 M4NSMPLS001 4 (THIS NUMBER SHOULD BE SET TO 4 FOR RISK ASSESSMENT)
- INITIAL SEED FOR RANDOM NUMBER GENERATOR 221 M4IRSEED001 79
- TERMINATOR RECORD ENCOUNTERED -- END OF BASE CASE USER INPUT ********
USER INPUT PROCESSING
SUMMARY
- BASE CASE
Calculation IP-CALC-09-00265, Rev. 0, Att. A.2, Page 9 NUMBER OF RECORDS READ = 449 NUMBER OF BLANK OR COMMENT RECORDS READ = 227 NUMBER OF TERMINATOR RECORDS = 1 NUMBER OF RECORDS PROCESSED = 221 NUMBER OF PROCESSED RECORDS DUPLICATED = 0 NUMBER OF PROCESSED RECORDS SORTED = 221 Decay Chain # Ba-139 Decay Chain # Ba-140 La-140 Fraction of Ba-140 going to La-140 in this chain = 1.000000 Decay Chain # Ce-143 Pr-143 Fraction of Ce-143 going to Pr-143 in this chain = 1.000000 Decay Chain # Ce-144 Decay Chain # Cm-242 Pu-238 Fraction of Cm-242 going to Pu-238 in this chain = 1.000000 Decay Chain # Cm-244 Pu-240 Fraction of Cm-244 going to Pu-240 in this chain = 1.000000 Decay Chain # Co-58 Decay Chain # Co-60 Decay Chain # Cs-134 Decay Chain # Cs-136 Decay Chain # Cs-137 Decay Chain # I-133 Xe-133 Fraction of I-133 going to Xe-133 in this chain = 0.971000 Decay Chain # I-134 Decay Chain # I-135 Xe-135 Fraction of I-135 going to Xe-135 in this chain = 0.846000 Decay Chain # Kr-85m Kr-85 Fraction of Kr-85m going to Kr-85 in this chain = 0.211000 Decay Chain # Kr-87 Decay Chain # Kr-88 Decay Chain # La-141 Ce-141 Fraction of La-141 going to Ce-141 in this chain = 1.000000 Decay Chain # La-142 Decay Chain # Mo-99 Tc-99m Fraction of Mo-99 going to Tc-99m in this chain = 0.876000
Calculation IP-CALC-09-00265, Rev. 0, Att. A.2, Page 10 Decay Chain # Nd-147 Decay Chain # Np-239 Pu-239 Fraction of Np-239 going to Pu-239 in this chain = 1.000000 Decay Chain # Pu-241 Am-241 Fraction of Pu-241 going to Am-241 in this chain = 1.000000 Decay Chain # Rb-86 Decay Chain # Ru-103 Decay Chain # Ru-105 Rh-105 Fraction of Ru-105 going to Rh-105 in this chain = 1.000000 Decay Chain # Ru-106 Decay Chain # Sb-127 Te-127 Fraction of Sb-127 going to Te-127 in this chain = 0.824000 Decay Chain # Sb-127 Te-127m Te-127 Fraction of Sb-127 going to Te-127m in this chain = 0.176000 Fraction of Sb-127 going to Te-127 in this chain = 0.171776 Fraction of Te-127m going to Te-127 in this chain = 0.976000 Decay Chain # Sb-129 Te-129 Fraction of Sb-129 going to Te-129 in this chain = 0.775000 Decay Chain # Sb-129 Te-129m Te-129 Fraction of Sb-129 going to Te-129m in this chain = 0.225000 Fraction of Sb-129 going to Te-129 in this chain = 0.146250 Fraction of Te-129m going to Te-129 in this chain = 0.650000 Decay Chain # Sr-89 Decay Chain # Sr-90 Y-90 Fraction of Sr-90 going to Y-90 in this chain = 1.000000 Decay Chain # Sr-91 Y-91 Fraction of Sr-91 going to Y-91 in this chain = 0.422000 Decay Chain # Sr-92 Y-92 Fraction of Sr-92 going to Y-92 in this chain = 1.000000 Decay Chain # Te-131m I-131 Fraction of Te-131m going to I-131 in this chain = 0.778000 Decay Chain # Te-132 I-132 Fraction of Te-132 going to I-132 in this chain = 1.000000 Decay Chain # Y-93 Decay Chain # Zr-95 Nb-95 Fraction of Zr-95 going to Nb-95 in this chain = 0.993000 Decay Chain # Zr-97 RELEASED INVENTORY OF ALL PLUMES
Calculation IP-CALC-09-00265, Rev. 0, Att. A.2, Page 11 Co-58 1.57E+10 Co-60 1.21E+10 Kr-85 3.72E+12 Kr-85m 1.28E+13 Kr-87 2.27E+11 Kr-88 1.18E+13 Rb-86 2.18E+10 Sr-89 1.87E+11 Sr-90 1.87E+10 Sr-91 9.84E+10 Sr-92 1.19E+10 Y-90 3.21E+09 Y-91 1.34E+10 Y-92 4.22E+10 Y-93 7.02E+09 Zr-95 1.77E+10 Zr-97 1.09E+10 Nb-95 1.80E+10 Mo-99 2.80E+12 Tc-99m 2.63E+12 Ru-103 2.50E+12 Ru-105 2.67E+11 Ru-106 8.78E+11 Rh-105 1.42E+12 Sb-127 6.62E+11 Sb-129 3.18E+11 Te-127 6.84E+11 Te-127m 9.40E+10 Te-129 5.40E+11 Te-129m 3.12E+11 Te-131m 7.38E+11 Te-132 8.57E+12 I-131 1.98E+13 I-132 9.38E+12 I-133 2.86E+13 I-134 3.54E+09 I-135 1.13E+13 Xe-133 5.64E+14 Xe-135 7.47E+13 Cs-134 1.93E+12 Cs-136 5.47E+11 Cs-137 1.12E+12 Ba-139 2.53E+09 Ba-140 9.77E+11 La-140 2.00E+11 La-141 2.12E+09 La-142 7.74E+07 Ce-141 1.42E+11 Ce-143 1.05E+11 Ce-144 1.13E+11 Pr-143 1.84E+10 Nd-147 6.78E+09 Np-239 1.52E+12 Pu-238 3.86E+08 Pu-239 3.30E+07 Pu-240 4.91E+07 Pu-241 1.10E+10 Am-241 1.68E+06 Cm-242 3.98E+08
Calculation IP-CALC-09-00265, Rev. 0, Att. A.2, Page 12 Cm-244 4.26E+07 READING FROM A WEATHER FILE WITH THE FOLLOWING HEADER:
INDIAN POINT ENERGY CENTER METEORLOGICAL DATAFILE Input file for the MACCS2 model using the year 2000 METEOROLOGICAL DATA FILE CONTAINS 397 HOURS OF OBSERVED RAIN DATA.
ACCUMULATED RAIN MEASUREMENTS TOTALED 30.31 INCHES FOR THE YEAR.
CONSTANT LID HEIGHTS (M) FOR 4 SEASONS = 1100 1500 1500 1300 NON-ZERO WINDSPEEDS LESS THAN 0.5 M/S ARE SET TO 0.5 M/S NUMTRI= 155
- * *
- METEOROLOGICAL BIN
SUMMARY
BIN PRIORITIES RI XX - RAIN INTENSITY I WITHIN THE INTERVAL ENDING AT XX INTERVAL ENDPOINTS ARE IN KILOMETERS FROM THE ACCIDENT SITE, THE 6 INTERVAL ENDPOINTS ARE 3 6 11 16 32 65 RAIN INTENSITIES ARE IN MILLIMETERS OF RAIN PER HOUR, THE 3 INTENSITY BREAKPOINTS ARE 2.0 4.0 6.0 S V - INITIAL WEATHER CONDITIONS WITH STABILITY CLASS S AND WIND SPEED INTERVAL V STABILITY CLASSES ARE B = A/B, D = C/D, E = E, AND F = F WIND SPEED INTERVALS ARE IN METERS PER SECOND, 1 (0-1), 2 (1-2), 3 (2-3), 4 (3-5), 5 (5-7), 6 (GT 7)
WIND DIRECTION METBIN 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 TOTAL PER CENT 1 B 3 0.083 0.009 0.009 0.092 0.083 0.128 0.165 0.174 0.092 0.000 0.009 0.000 0.000 0.009 0.000 0.147 109 1.2443 2 B 4 0.066 0.033 0.022 0.000 0.022 0.044 0.154 0.077 0.275 0.055 0.000 0.000 0.000 0.000 0.000 0.253 91 1.0388 3 D 1 0.115 0.073 0.055 0.032 0.009 0.014 0.005 0.023 0.032 0.064 0.060 0.064 0.115 0.101 0.142 0.096 218 2.4886 4 D 2 0.158 0.092 0.041 0.049 0.047 0.039 0.046 0.063 0.109 0.113 0.071 0.043 0.020 0.012 0.025 0.071 1377 15.7192 5 D 3 0.124 0.047 0.021 0.033 0.067 0.107 0.099 0.102 0.192 0.125 0.029 0.004 0.002 0.000 0.003 0.046 1699 19.3950 6 D 4 0.075 0.020 0.007 0.011 0.040 0.129 0.191 0.111 0.223 0.138 0.017 0.001 0.000 0.000 0.001 0.036 1453 16.5868 7 D 5 0.055 0.021 0.014 0.000 0.021 0.034 0.274 0.068 0.342 0.144 0.000 0.000 0.000 0.000 0.000 0.027 146 1.6667 8 D 6 0.000 0.000 0.000 0.000 0.200 0.000 0.000 0.200 0.400 0.200 0.000 0.000 0.000 0.000 0.000 0.000 5 0.0571 9 E 1 0.118 0.087 0.076 0.037 0.022 0.028 0.024 0.031 0.081 0.109 0.061 0.059 0.041 0.072 0.081 0.076 543 6.1986 10 E 2 0.188 0.094 0.065 0.026 0.017 0.007 0.009 0.010 0.047 0.190 0.163 0.051 0.024 0.010 0.013 0.087 898 10.2511 11 E 3 0.227 0.054 0.003 0.003 0.007 0.007 0.003 0.014 0.044 0.424 0.163 0.003 0.000 0.000 0.000 0.047 295 3.3676 12 E 4 0.298 0.053 0.035 0.000 0.000 0.018 0.000 0.018 0.246 0.211 0.035 0.000 0.000 0.000 0.000 0.088 57 0.6507 13 F 1 0.051 0.017 0.039 0.000 0.022 0.034 0.045 0.090 0.225 0.208 0.073 0.056 0.034 0.011 0.045 0.051 178 2.0320 14 F 2 0.017 0.008 0.008 0.004 0.008 0.000 0.000 0.004 0.054 0.675 0.171 0.033 0.004 0.004 0.000 0.008 240 2.7397 15 F 3 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.707 0.276 0.000 0.000 0.000 0.000 0.017 58 0.6621 16 F 4 0.143 0.000 0.000 0.000 0.000 0.143 0.000 0.000 0.000 0.429 0.286 0.000 0.000 0.000 0.000 0.000 7 0.0799 17 R1 3 0.107 0.017 0.014 0.014 0.007 0.031 0.034 0.038 0.214 0.259 0.055 0.034 0.041 0.045 0.034 0.055 290 3.3105 18 R1 6 0.149 0.043 0.021 0.000 0.000 0.000 0.000 0.000 0.106 0.106 0.085 0.128 0.128 0.085 0.043 0.106 47 0.5365 19 R1 11 0.095 0.053 0.032 0.000 0.000 0.042 0.011 0.021 0.084 0.253 0.074 0.074 0.074 0.021 0.063 0.105 95 1.0845 20 R1 16 0.192 0.041 0.000 0.014 0.014 0.027 0.014 0.055 0.110 0.164 0.055 0.055 0.027 0.082 0.041 0.110 73 0.8333 21 R1 32 0.149 0.035 0.045 0.015 0.005 0.040 0.005 0.015 0.069 0.243 0.099 0.050 0.035 0.030 0.020 0.149 202 2.3059 22 R1 65 0.124 0.074 0.029 0.021 0.018 0.029 0.003 0.029 0.115 0.203 0.109 0.029 0.026 0.035 0.021 0.135 340 3.8813 23 R2 3 0.108 0.031 0.000 0.015 0.031 0.000 0.015 0.046 0.231 0.277 0.062 0.046 0.015 0.046 0.000 0.077 65 0.7420 24 R2 6 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.200 0.000 0.000 0.000 0.000 0.200 0.400 0.200 5 0.0571 25 R2 11 0.214 0.071 0.000 0.000 0.000 0.000 0.000 0.071 0.071 0.143 0.000 0.000 0.000 0.000 0.071 0.357 14 0.1598 26 R2 16 0.429 0.143 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.143 0.000 0.000 0.000 0.000 0.143 0.143 7 0.0799 27 R2 32 0.263 0.211 0.000 0.000 0.000 0.000 0.000 0.000 0.053 0.211 0.053 0.000 0.053 0.000 0.053 0.105 19 0.2169 28 R2 65 0.233 0.047 0.070 0.023 0.000 0.000 0.000 0.000 0.070 0.163 0.116 0.023 0.023 0.023 0.093 0.116 43 0.4909 29 R3 3 0.143 0.048 0.048 0.000 0.048 0.000 0.000 0.000 0.095 0.286 0.048 0.095 0.048 0.048 0.000 0.095 21 0.2397 30 R3 6 0.250 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.250 0.250 0.000 0.000 0.250 4 0.0457 31 R3 11 0.000 0.286 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.286 0.143 0.286 7 0.0799 32 R3 16 0.500 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.500 0.000 2 0.0228 33 R3 32 0.214 0.357 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.071 0.000 0.000 0.071 0.143 0.000 0.143 14 0.1598 34 R3 65 0.276 0.138 0.000 0.000 0.034 0.000 0.000 0.034 0.034 0.172 0.069 0.000 0.034 0.000 0.000 0.207 29 0.3311 35 R4 3 0.133 0.033 0.000 0.033 0.000 0.033 0.000 0.000 0.033 0.300 0.033 0.067 0.067 0.067 0.100 0.100 30 0.3425
Calculation IP-CALC-09-00265, Rev. 0, Att. A.2, Page 13 36 R4 6 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 1.000 1 0.0114 37 R4 11 0.200 0.300 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.200 0.100 0.000 0.100 0.000 0.000 0.100 10 0.1142 38 R4 16 0.000 0.000 0.167 0.167 0.000 0.000 0.000 0.000 0.000 0.333 0.167 0.000 0.000 0.000 0.167 0.000 6 0.0685 39 R4 32 0.227 0.045 0.091 0.136 0.000 0.045 0.000 0.045 0.045 0.227 0.045 0.000 0.000 0.000 0.000 0.091 22 0.2511 40 R4 65 0.400 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.150 0.300 0.025 0.000 0.000 0.000 0.000 0.125 40 0.4566 41 ALL 0.128 0.056 0.030 0.025 0.035 0.059 0.072 0.063 0.140 0.174 0.068 0.027 0.018 0.017 0.021 0.069 8760
Calculation IP-CALC-09-00265, Rev. 0, Att. A.2, Page 14
- * *
- METEOROLOGICAL BIN
SUMMARY
BIN PRIORITIES RI XX - RAIN INTENSITY I WITHIN THE INTERVAL ENDING AT XX INTERVAL ENDPOINTS ARE IN KILOMETERS FROM THE ACCIDENT SITE, THE 6 INTERVAL ENDPOINTS ARE 3 6 11 16 32 65 RAIN INTENSITIES ARE IN MILLIMETERS OF RAIN PER HOUR, THE 3 INTENSITY BREAKPOINTS ARE 2.0 4.0 6.0 S V - INITIAL WEATHER CONDITIONS WITH STABILITY CLASS S AND WIND SPEED INTERVAL V STABILITY CLASSES ARE B = A/B, D = C/D, E = E, AND F = F WIND SPEED INTERVALS ARE IN METERS PER SECOND (M/S), 1 (0-1), 2 (1-2), 3 (2-3), 4 (3-5), 5 (5-7), 6 (GT 7)
WIND DIRECTION METBIN 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 TOTAL PER CENT 1 B 3 9 1 1 10 9 14 18 19 10 0 1 0 0 1 0 16 109 1.2443 2 B 4 6 3 2 0 2 4 14 7 25 5 0 0 0 0 0 23 91 1.0388 3 D 1 25 16 12 7 2 3 1 5 7 14 13 14 25 22 31 21 218 2.4886 4 D 2 218 127 57 67 65 54 64 87 150 155 98 59 27 16 35 98 1377 15.7192 5 D 3 210 80 35 56 114 181 168 174 326 213 49 7 3 0 5 78 1699 19.3950 6 D 4 109 29 10 16 58 187 278 162 324 201 25 1 0 0 1 52 1453 16.5868 7 D 5 8 3 2 0 3 5 40 10 50 21 0 0 0 0 0 4 146 1.6667 8 D 6 0 0 0 0 1 0 0 1 2 1 0 0 0 0 0 0 5 0.0571 9 E 1 64 47 41 20 12 15 13 17 44 59 33 32 22 39 44 41 543 6.1986 10 E 2 169 84 58 23 15 6 8 9 42 171 146 46 22 9 12 78 898 10.2511 11 E 3 67 16 1 1 2 2 1 4 13 125 48 1 0 0 0 14 295 3.3676 12 E 4 17 3 2 0 0 1 0 1 14 12 2 0 0 0 0 5 57 0.6507 13 F 1 9 3 7 0 4 6 8 16 40 37 13 10 6 2 8 9 178 2.0320 14 F 2 4 2 2 1 2 0 0 1 13 162 41 8 1 1 0 2 240 2.7397 15 F 3 0 0 0 0 0 0 0 0 0 41 16 0 0 0 0 1 58 0.6621 16 F 4 1 0 0 0 0 1 0 0 0 3 2 0 0 0 0 0 7 0.0799 17 R1 3 31 5 4 4 2 9 10 11 62 75 16 10 12 13 10 16 290 3.3105 18 R1 6 7 2 1 0 0 0 0 0 5 5 4 6 6 4 2 5 47 0.5365 19 R1 11 9 5 3 0 0 4 1 2 8 24 7 7 7 2 6 10 95 1.0845 20 R1 16 14 3 0 1 1 2 1 4 8 12 4 4 2 6 3 8 73 0.8333 21 R1 32 30 7 9 3 1 8 1 3 14 49 20 10 7 6 4 30 202 2.3059 22 R1 65 42 25 10 7 6 10 1 10 39 69 37 10 9 12 7 46 340 3.8813 23 R2 3 7 2 0 1 2 0 1 3 15 18 4 3 1 3 0 5 65 0.7420 24 R2 6 0 0 0 0 0 0 0 0 1 0 0 0 0 1 2 1 5 0.0571 25 R2 11 3 1 0 0 0 0 0 1 1 2 0 0 0 0 1 5 14 0.1598 26 R2 16 3 1 0 0 0 0 0 0 0 1 0 0 0 0 1 1 7 0.0799 27 R2 32 5 4 0 0 0 0 0 0 1 4 1 0 1 0 1 2 19 0.2169 28 R2 65 10 2 3 1 0 0 0 0 3 7 5 1 1 1 4 5 43 0.4909 29 R3 3 3 1 1 0 1 0 0 0 2 6 1 2 1 1 0 2 21 0.2397 30 R3 6 1 0 0 0 0 0 0 0 0 0 0 1 1 0 0 1 4 0.0457 31 R3 11 0 2 0 0 0 0 0 0 0 0 0 0 0 2 1 2 7 0.0799 32 R3 16 1 0 0 0 0 0 0 0 0 0 0 0 0 0 1 0 2 0.0228 33 R3 32 3 5 0 0 0 0 0 0 0 1 0 0 1 2 0 2 14 0.1598 34 R3 65 8 4 0 0 1 0 0 1 1 5 2 0 1 0 0 6 29 0.3311 35 R4 3 4 1 0 1 0 1 0 0 1 9 1 2 2 2 3 3 30 0.3425 36 R4 6 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1 1 0.0114 37 R4 11 2 3 0 0 0 0 0 0 0 2 1 0 1 0 0 1 10 0.1142 38 R4 16 0 0 1 1 0 0 0 0 0 2 1 0 0 0 1 0 6 0.0685 39 R4 32 5 1 2 3 0 1 0 1 1 5 1 0 0 0 0 2 22 0.2511 40 R4 65 16 0 0 0 0 0 0 0 6 12 1 0 0 0 0 5 40 0.4566
- * *
- SUMMARIES * * *
- R 204 74 34 22 14 35 15 36 168 308 106 56 53 55 47 159 1386 15.8219 B 15 4 3 10 11 18 32 26 35 5 1 0 0 1 0 39 200 2.2831
Calculation IP-CALC-09-00265, Rev. 0, Att. A.2, Page 15 D 570 255 116 146 243 430 551 439 859 605 185 81 55 38 72 253 4898 55.9132 E 317 150 102 44 29 24 22 31 113 367 229 79 44 48 56 138 1793 20.4680 F 14 5 9 1 6 7 8 17 53 243 72 18 7 3 8 12 483 5.5137 1 98 66 60 27 18 24 22 38 91 110 59 56 53 63 83 71 939 10.7192 2 391 213 117 92 83 60 78 101 206 488 286 113 50 26 47 180 2531 28.8927 3 286 97 37 66 124 197 181 193 348 379 113 8 3 1 5 107 2145 24.4863 4 132 34 14 16 60 193 292 170 360 221 29 1 0 0 1 79 1602 18.2877 5 9 4 2 0 3 5 40 10 53 21 0 0 0 0 0 5 152 1.7352 6 0 0 0 0 1 0 0 1 2 1 0 0 0 0 0 0 5 0.0571
Calculation IP-CALC-09-00265, Rev. 0, Att. A.2, Page 16
- * * *
- BIN WINDROSE
SUMMARY
BIN DIRECTION TOTAL 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 1 0.083 0.009 0.009 0.092 0.083 0.128 0.165 0.174 0.092 0.000 0.009 0.000 0.000 0.009 0.000 0.147 1.000000 2 0.066 0.033 0.022 0.000 0.022 0.044 0.154 0.077 0.275 0.055 0.000 0.000 0.000 0.000 0.000 0.253 1.000000 3 0.115 0.073 0.055 0.032 0.009 0.014 0.005 0.023 0.032 0.064 0.060 0.064 0.115 0.101 0.142 0.096 1.000000 4 0.158 0.092 0.041 0.049 0.047 0.039 0.046 0.063 0.109 0.113 0.071 0.043 0.020 0.012 0.025 0.071 1.000000 5 0.124 0.047 0.021 0.033 0.067 0.107 0.099 0.102 0.192 0.125 0.029 0.004 0.002 0.000 0.003 0.046 1.000000 6 0.075 0.020 0.007 0.011 0.040 0.129 0.191 0.111 0.223 0.138 0.017 0.001 0.000 0.000 0.001 0.036 1.000000 7 0.055 0.021 0.014 0.000 0.021 0.034 0.274 0.068 0.342 0.144 0.000 0.000 0.000 0.000 0.000 0.027 1.000000 8 0.000 0.000 0.000 0.000 0.200 0.000 0.000 0.200 0.400 0.200 0.000 0.000 0.000 0.000 0.000 0.000 1.000000 9 0.118 0.087 0.076 0.037 0.022 0.028 0.024 0.031 0.081 0.109 0.061 0.059 0.041 0.072 0.081 0.076 1.000000 10 0.188 0.094 0.065 0.026 0.017 0.007 0.009 0.010 0.047 0.190 0.163 0.051 0.024 0.010 0.013 0.087 1.000000 11 0.227 0.054 0.003 0.003 0.007 0.007 0.003 0.014 0.044 0.424 0.163 0.003 0.000 0.000 0.000 0.047 1.000000 12 0.298 0.053 0.035 0.000 0.000 0.018 0.000 0.018 0.246 0.211 0.035 0.000 0.000 0.000 0.000 0.088 1.000000 13 0.051 0.017 0.039 0.000 0.022 0.034 0.045 0.090 0.225 0.208 0.073 0.056 0.034 0.011 0.045 0.051 1.000000 14 0.017 0.008 0.008 0.004 0.008 0.000 0.000 0.004 0.054 0.675 0.171 0.033 0.004 0.004 0.000 0.008 1.000000 15 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.707 0.276 0.000 0.000 0.000 0.000 0.017 1.000000 16 0.143 0.000 0.000 0.000 0.000 0.143 0.000 0.000 0.000 0.429 0.286 0.000 0.000 0.000 0.000 0.000 1.000000 17 0.147 0.053 0.025 0.016 0.010 0.025 0.011 0.026 0.121 0.222 0.076 0.040 0.038 0.040 0.034 0.115 1.000000 18 0.147 0.053 0.025 0.016 0.010 0.025 0.011 0.026 0.121 0.222 0.076 0.040 0.038 0.040 0.034 0.115 1.000000 19 0.147 0.053 0.025 0.016 0.010 0.025 0.011 0.026 0.121 0.222 0.076 0.040 0.038 0.040 0.034 0.115 1.000000 20 0.147 0.053 0.025 0.016 0.010 0.025 0.011 0.026 0.121 0.222 0.076 0.040 0.038 0.040 0.034 0.115 1.000000 21 0.147 0.053 0.025 0.016 0.010 0.025 0.011 0.026 0.121 0.222 0.076 0.040 0.038 0.040 0.034 0.115 1.000000 22 0.147 0.053 0.025 0.016 0.010 0.025 0.011 0.026 0.121 0.222 0.076 0.040 0.038 0.040 0.034 0.115 1.000000 23 0.147 0.053 0.025 0.016 0.010 0.025 0.011 0.026 0.121 0.222 0.076 0.040 0.038 0.040 0.034 0.115 1.000000 24 0.147 0.053 0.025 0.016 0.010 0.025 0.011 0.026 0.121 0.222 0.076 0.040 0.038 0.040 0.034 0.115 1.000000 25 0.147 0.053 0.025 0.016 0.010 0.025 0.011 0.026 0.121 0.222 0.076 0.040 0.038 0.040 0.034 0.115 1.000000 26 0.147 0.053 0.025 0.016 0.010 0.025 0.011 0.026 0.121 0.222 0.076 0.040 0.038 0.040 0.034 0.115 1.000000 27 0.147 0.053 0.025 0.016 0.010 0.025 0.011 0.026 0.121 0.222 0.076 0.040 0.038 0.040 0.034 0.115 1.000000 28 0.147 0.053 0.025 0.016 0.010 0.025 0.011 0.026 0.121 0.222 0.076 0.040 0.038 0.040 0.034 0.115 1.000000 29 0.147 0.053 0.025 0.016 0.010 0.025 0.011 0.026 0.121 0.222 0.076 0.040 0.038 0.040 0.034 0.115 1.000000 30 0.147 0.053 0.025 0.016 0.010 0.025 0.011 0.026 0.121 0.222 0.076 0.040 0.038 0.040 0.034 0.115 1.000000 31 0.147 0.053 0.025 0.016 0.010 0.025 0.011 0.026 0.121 0.222 0.076 0.040 0.038 0.040 0.034 0.115 1.000000 32 0.147 0.053 0.025 0.016 0.010 0.025 0.011 0.026 0.121 0.222 0.076 0.040 0.038 0.040 0.034 0.115 1.000000 33 0.147 0.053 0.025 0.016 0.010 0.025 0.011 0.026 0.121 0.222 0.076 0.040 0.038 0.040 0.034 0.115 1.000000 34 0.147 0.053 0.025 0.016 0.010 0.025 0.011 0.026 0.121 0.222 0.076 0.040 0.038 0.040 0.034 0.115 1.000000 35 0.147 0.053 0.025 0.016 0.010 0.025 0.011 0.026 0.121 0.222 0.076 0.040 0.038 0.040 0.034 0.115 1.000000 36 0.147 0.053 0.025 0.016 0.010 0.025 0.011 0.026 0.121 0.222 0.076 0.040 0.038 0.040 0.034 0.115 1.000000 37 0.147 0.053 0.025 0.016 0.010 0.025 0.011 0.026 0.121 0.222 0.076 0.040 0.038 0.040 0.034 0.115 1.000000 38 0.147 0.053 0.025 0.016 0.010 0.025 0.011 0.026 0.121 0.222 0.076 0.040 0.038 0.040 0.034 0.115 1.000000 39 0.147 0.053 0.025 0.016 0.010 0.025 0.011 0.026 0.121 0.222 0.076 0.040 0.038 0.040 0.034 0.115 1.000000 40 0.147 0.053 0.025 0.016 0.010 0.025 0.011 0.026 0.121 0.222 0.076 0.040 0.038 0.040 0.034 0.115 1.000000 41 0.128 0.056 0.030 0.025 0.035 0.059 0.072 0.063 0.140 0.174 0.068 0.027 0.018 0.017 0.021 0.069 1.000000
- BEGINNING OF CHANGE CASE 1 USER INPUT ********
- RELEASE DATA BLOCK *************
- SOURCE TERM NUMBER 2 OF 8 222 RDATNAM2001 'EARLY HIGH'
- RECORD NUMBER 222 REPLACES RECORD NUMBER 123 ********
223 RDOALARM001 1.27E+04
- RECORD NUMBER 223 REPLACES RECORD NUMBER 124 ********
224 RDNUMREL001 1
- RECORD NUMBER 224 REPLACES RECORD NUMBER 125 ********
225 RDMAXRIS001 1
Calculation IP-CALC-09-00265, Rev. 0, Att. A.2, Page 17
- RECORD NUMBER 225 REPLACES RECORD NUMBER 126 ********
226 RDREFTIM001 0.0
- RECORD NUMBER 226 REPLACES RECORD NUMBER 127 ********
227 RDPLHEAT001 1.03E+06
- RECORD NUMBER 227 REPLACES RECORD NUMBER 128 ********
228 RDPLHITE001 30.
- RECORD NUMBER 228 REPLACES RECORD NUMBER 129 ********
229 RDPLUDUR001 7.92E+04
- RECORD NUMBER 229 REPLACES RECORD NUMBER 130 ********
230 RDPDELAY001 1.20E+04
- RECORD NUMBER 230 REPLACES RECORD NUMBER 131 ********
- Xe/Kr I Cs Te Sr Ru La Ce Ba 231 RDRELFRC001 6.4E-01 1.6E-01 1.5E-01 1.5E-01 1.6E-02 6.5E-02 5.6E-04 3.0E-03 3.1E-02
- RECORD NUMBER 231 REPLACES RECORD NUMBER 206 ********
- TERMINATOR RECORD ENCOUNTERED -- END OF CHANGE CASE 1 USER INPUT ********
USER INPUT PROCESSING
SUMMARY
- CHANGE CASE 1 NUMBER OF RECORDS CHANGED = 10 NUMBER OF RECORDS ADDED = 0 RELEASED INVENTORY OF ALL PLUMES Co-58 1.97E+15 Co-60 1.51E+15 Kr-85 2.48E+16 Kr-85m 3.26E+17 Kr-87 1.71E+17 Kr-88 6.53E+17 Rb-86 1.23E+15 Sr-89 4.93E+16 Sr-90 4.91E+15 Sr-91 4.86E+16 Sr-92 2.86E+16 Y-90 3.47E+14 Y-91 2.26E+15 Y-92 2.19E+16 Y-93 2.16E+15 Zr-95 3.01E+15 Zr-97 2.64E+15 Nb-95 3.05E+15 Mo-99 3.83E+17 Tc-99m 3.45E+17 Ru-103 3.14E+17 Ru-105 1.29E+17 Ru-106 1.10E+17 Rh-105 1.98E+17 Sb-127 5.05E+16 Sb-129 9.14E+16 Te-127 5.08E+16 Te-127m 6.71E+15 Te-129 1.08E+17 Te-129m 2.24E+16 Te-131m 6.44E+16 Te-132 6.61E+17
Calculation IP-CALC-09-00265, Rev. 0, Att. A.2, Page 18 I-131 5.03E+17 I-132 6.96E+17 I-133 9.39E+17 I-134 8.25E+16 I-135 6.93E+17 Xe-133 3.94E+18 Xe-135 9.85E+17 Cs-134 1.07E+17 Cs-136 3.10E+16 Cs-137 6.22E+16 Ba-139 3.40E+16 Ba-140 1.72E+17 La-140 1.27E+16 La-141 1.66E+15 La-142 6.47E+14 Ce-141 1.59E+16 Ce-143 1.40E+16 Ce-144 1.26E+16 Pr-143 2.76E+15 Nd-147 1.18E+15 Np-239 1.88E+17 Pu-238 4.29E+13 Pu-239 3.66E+12 Pu-240 5.46E+12 Pu-241 1.22E+15 Am-241 2.82E+11 Cm-242 6.77E+13 Cm-244 7.22E+12
- BEGINNING OF CHANGE CASE 2 USER INPUT ********
- RELEASE DATA BLOCK *************
- SOURCE TERM NUMBER 3 OF 8 232 RDATNAM2001 'EARLY MEDIUM'
- RECORD NUMBER 232 REPLACES RECORD NUMBER 123 ********
233 RDOALARM001 9.18E+03
- RECORD NUMBER 233 REPLACES RECORD NUMBER 124 ********
234 RDNUMREL001 1
- RECORD NUMBER 234 REPLACES RECORD NUMBER 125 ********
235 RDMAXRIS001 1
- RECORD NUMBER 235 REPLACES RECORD NUMBER 126 ********
236 RDREFTIM001 0.0
- RECORD NUMBER 236 REPLACES RECORD NUMBER 127 ********
237 RDPLHEAT001 1.07E+06
- RECORD NUMBER 237 REPLACES RECORD NUMBER 128 ********
238 RDPLHITE001 30.
- RECORD NUMBER 238 REPLACES RECORD NUMBER 129 ********
239 RDPLUDUR001 8.21E+04
- RECORD NUMBER 239 REPLACES RECORD NUMBER 130 ********
240 RDPDELAY001 9.22E+03
- RECORD NUMBER 240 REPLACES RECORD NUMBER 131 ********
- Xe/Kr I Cs Te Sr Ru La Ce Ba 241 RDRELFRC001 9.9E-01 1.3E-02 1.2E-02 2.7E-02 8.5E-04 3.0E-02 5.2E-05 3.1E-04 2.0E-02
- RECORD NUMBER 241 REPLACES RECORD NUMBER 206 ********
- TERMINATOR RECORD ENCOUNTERED -- END OF CHANGE CASE 2 USER INPUT ********
Calculation IP-CALC-09-00265, Rev. 0, Att. A.2, Page 19 USER INPUT PROCESSING
SUMMARY
- CHANGE CASE 2 NUMBER OF RECORDS CHANGED = 10 NUMBER OF RECORDS ADDED = 0 RELEASED INVENTORY OF ALL PLUMES Co-58 9.11E+14 Co-60 6.96E+14 Kr-85 3.83E+16 Kr-85m 5.68E+17 Kr-87 4.02E+17 Kr-88 1.22E+18 Rb-86 9.85E+13 Sr-89 2.62E+15 Sr-90 2.61E+14 Sr-91 2.73E+15 Sr-92 1.85E+15 Y-90 2.33E+13 Y-91 2.08E+14 Y-92 1.14E+15 Y-93 2.12E+14 Zr-95 2.79E+14 Zr-97 2.53E+14 Nb-95 2.83E+14 Mo-99 1.78E+17 Tc-99m 1.60E+17 Ru-103 1.45E+17 Ru-105 6.72E+16 Ru-106 5.07E+16 Rh-105 9.19E+16 Sb-127 9.14E+15 Sb-129 1.86E+16 Te-127 9.18E+15 Te-127m 1.21E+15 Te-129 2.13E+16 Te-129m 4.03E+15 Te-131m 1.18E+16 Te-132 1.20E+17 I-131 4.10E+16 I-132 9.30E+16 I-133 7.83E+16 I-134 1.23E+16 I-135 6.10E+16 Xe-133 6.10E+18 Xe-135 1.37E+18 Cs-134 8.59E+15 Cs-136 2.48E+15 Cs-137 4.98E+15 Ba-139 3.23E+16 Ba-140 1.11E+17 La-140 5.09E+15 La-141 1.77E+14 La-142 8.50E+13 Ce-141 1.64E+15 Ce-143 1.47E+15
Calculation IP-CALC-09-00265, Rev. 0, Att. A.2, Page 20 Ce-144 1.30E+15 Pr-143 2.55E+14 Nd-147 1.09E+14 Np-239 1.96E+16 Pu-238 4.43E+12 Pu-239 3.78E+11 Pu-240 5.64E+11 Pu-241 1.26E+14 Am-241 2.62E+10 Cm-242 6.29E+12 Cm-244 6.71E+11
- BEGINNING OF CHANGE CASE 3 USER INPUT ********
- RELEASE DATA BLOCK *************
- SOURCE TERM NUMBER 4 OF 8 242 RDATNAM2001 'EARLY LOW'
- RECORD NUMBER 242 REPLACES RECORD NUMBER 123 ********
243 RDOALARM001 9.31E+03
- RECORD NUMBER 243 REPLACES RECORD NUMBER 124 ********
244 RDNUMREL001 1
- RECORD NUMBER 244 REPLACES RECORD NUMBER 125 ********
245 RDMAXRIS001 1
- RECORD NUMBER 245 REPLACES RECORD NUMBER 126 ********
246 RDREFTIM001 0.0
- RECORD NUMBER 246 REPLACES RECORD NUMBER 127 ********
247 RDPLHEAT001 1.11E+06
- RECORD NUMBER 247 REPLACES RECORD NUMBER 128 ********
248 RDPLHITE001 30.
- RECORD NUMBER 248 REPLACES RECORD NUMBER 129 ********
249 RDPLUDUR001 8.49E+04
- RECORD NUMBER 249 REPLACES RECORD NUMBER 130 ********
250 RDPDELAY001 9.90E+03
- RECORD NUMBER 250 REPLACES RECORD NUMBER 131 ********
- Xe/Kr I Cs Te Sr Ru La Ce Ba 251 RDRELFRC001 2.4E-01 2.0E-03 1.6E-03 2.9E-03 9.0E-05 3.0E-03 5.2E-06 3.1E-05 1.9E-03
- RECORD NUMBER 251 REPLACES RECORD NUMBER 206 ********
- TERMINATOR RECORD ENCOUNTERED -- END OF CHANGE CASE 3 USER INPUT ********
USER INPUT PROCESSING
SUMMARY
- CHANGE CASE 3 NUMBER OF RECORDS CHANGED = 10 NUMBER OF RECORDS ADDED = 0 RELEASED INVENTORY OF ALL PLUMES Co-58 9.11E+13 Co-60 6.96E+13 Kr-85 9.29E+15 Kr-85m 1.34E+17 Kr-87 8.79E+16 Kr-88 2.82E+17 Rb-86 1.31E+13
Calculation IP-CALC-09-00265, Rev. 0, Att. A.2, Page 21 Sr-89 2.78E+14 Sr-90 2.76E+13 Sr-91 2.85E+14 Sr-92 1.87E+14 Y-90 2.43E+12 Y-91 2.08E+13 Y-92 1.22E+14 Y-93 2.09E+13 Zr-95 2.79E+13 Zr-97 2.51E+13 Nb-95 2.83E+13 Mo-99 1.78E+16 Tc-99m 1.60E+16 Ru-103 1.45E+16 Ru-105 6.52E+15 Ru-106 5.07E+15 Rh-105 9.18E+15 Sb-127 9.80E+14 Sb-129 1.94E+15 Te-127 9.85E+14 Te-127m 1.30E+14 Te-129 2.24E+15 Te-129m 4.32E+14 Te-131m 1.26E+15 Te-132 1.28E+16 I-131 6.31E+15 I-132 1.14E+16 I-133 1.20E+16 I-134 1.63E+15 I-135 9.20E+15 Xe-133 1.48E+18 Xe-135 3.27E+17 Cs-134 1.15E+15 Cs-136 3.31E+14 Cs-137 6.64E+14 Ba-139 2.79E+15 Ba-140 1.05E+16 La-140 5.17E+14 La-141 1.71E+13 La-142 7.81E+12 Ce-141 1.64E+14 Ce-143 1.46E+14 Ce-144 1.30E+14 Pr-143 2.56E+13 Nd-147 1.09E+13 Np-239 1.96E+15 Pu-238 4.43E+11 Pu-239 3.78E+10 Pu-240 5.64E+10 Pu-241 1.26E+13 Am-241 2.62E+09 Cm-242 6.29E+11 Cm-244 6.71E+10
- BEGINNING OF CHANGE CASE 4 USER INPUT ********
- RELEASE DATA BLOCK *************
- SOURCE TERM NUMBER 5 OF 8
Calculation IP-CALC-09-00265, Rev. 0, Att. A.2, Page 22 252 RDATNAM2001 'LATE HIGH'
- RECORD NUMBER 252 REPLACES RECORD NUMBER 123 ********
253 RDOALARM001 5.58E+03
- RECORD NUMBER 253 REPLACES RECORD NUMBER 124 ********
254 RDNUMREL001 1
- RECORD NUMBER 254 REPLACES RECORD NUMBER 125 ********
255 RDMAXRIS001 1
- RECORD NUMBER 255 REPLACES RECORD NUMBER 126 ********
256 RDREFTIM001 0.5
- RECORD NUMBER 256 REPLACES RECORD NUMBER 127 ********
257 RDPLHEAT001 9.20E+05
- RECORD NUMBER 257 REPLACES RECORD NUMBER 128 ********
258 RDPLHITE001 30.
- RECORD NUMBER 258 REPLACES RECORD NUMBER 129 ********
259 RDPLUDUR001 8.64E+04
- RECORD NUMBER 259 REPLACES RECORD NUMBER 130 ********
260 RDPDELAY001 7.38E+04
- RECORD NUMBER 260 REPLACES RECORD NUMBER 131 ********
- Xe/Kr I Cs Te Sr Ru La Ce Ba 261 RDRELFRC001 9.9E-01 1.2E-01 2.3E-02 4.8E-03 2.1E-04 3.7E-03 1.3E-05 1.2E-04 9.1E-04
- RECORD NUMBER 261 REPLACES RECORD NUMBER 206 ********
- TERMINATOR RECORD ENCOUNTERED -- END OF CHANGE CASE 4 USER INPUT ********
USER INPUT PROCESSING
SUMMARY
- CHANGE CASE 4 NUMBER OF RECORDS CHANGED = 10 NUMBER OF RECORDS ADDED = 0 RELEASED INVENTORY OF ALL PLUMES Co-58 1.11E+14 Co-60 8.58E+13 Kr-85 3.83E+16 Kr-85m 5.52E+15 Kr-87 3.29E+10 Kr-88 8.17E+14 Rb-86 1.80E+14 Sr-89 6.37E+14 Sr-90 6.45E+13 Sr-91 7.59E+13 Sr-92 2.16E+11 Y-90 2.21E+13 Y-91 5.30E+13 Y-92 4.34E+12 Y-93 6.78E+12 Zr-95 6.89E+13 Zr-97 1.85E+13 Nb-95 7.08E+13 Mo-99 1.61E+16 Tc-99m 1.54E+16 Ru-103 1.75E+16 Ru-105 7.74E+13 Ru-106 6.24E+15 Rh-105 6.95E+15
Calculation IP-CALC-09-00265, Rev. 0, Att. A.2, Page 23 Sb-127 1.30E+15 Sb-129 2.71E+13 Te-127 1.39E+15 Te-127m 2.15E+14 Te-129 4.85E+14 Te-129m 7.01E+14 Te-131m 1.05E+15 Te-132 1.63E+16 I-131 3.40E+17 I-132 1.69E+16 I-133 2.67E+17 I-134 5.97E+06 I-135 2.44E+16 Xe-133 5.25E+18 Xe-135 2.23E+17 Cs-134 1.64E+16 Cs-136 4.45E+15 Cs-137 9.54E+15 Ba-139 4.25E+08 Ba-140 4.72E+15 La-140 2.13E+15 La-141 2.25E+11 La-142 3.03E+07 Ce-141 6.19E+14 Ce-143 3.03E+14 Ce-144 5.01E+14 Pr-143 8.69E+13 Nd-147 2.53E+13 Np-239 5.26E+15 Pu-238 1.72E+12 Pu-239 1.47E+11 Pu-240 2.18E+11 Pu-241 4.90E+13 Am-241 6.83E+09 Cm-242 1.56E+12 Cm-244 1.68E+11
- BEGINNING OF CHANGE CASE 5 USER INPUT ********
- RELEASE DATA BLOCK *************
- SOURCE TERM NUMBER 6 OF 8 262 RDATNAM2001 'LATE MEDIUM'
- RECORD NUMBER 262 REPLACES RECORD NUMBER 123 ********
263 RDOALARM001 7.17E+03
- RECORD NUMBER 263 REPLACES RECORD NUMBER 124 ********
264 RDNUMREL001 1
- RECORD NUMBER 264 REPLACES RECORD NUMBER 125 ********
265 RDMAXRIS001 1
- RECORD NUMBER 265 REPLACES RECORD NUMBER 126 ********
266 RDREFTIM001 0.5
- RECORD NUMBER 266 REPLACES RECORD NUMBER 127 ********
267 RDPLHEAT001 9.20E+05
- RECORD NUMBER 267 REPLACES RECORD NUMBER 128 ********
268 RDPLHITE001 30.
- RECORD NUMBER 268 REPLACES RECORD NUMBER 129 ********
269 RDPLUDUR001 8.64E+04
- RECORD NUMBER 269 REPLACES RECORD NUMBER 130 ********
Calculation IP-CALC-09-00265, Rev. 0, Att. A.2, Page 24 270 RDPDELAY001 7.70E+04
- RECORD NUMBER 270 REPLACES RECORD NUMBER 131 ********
- Xe/Kr I Cs Te Sr Ru La Ce Ba 271 RDRELFRC001 8.2E-01 1.5E-02 4.3E-03 1.5E-03 8.0E-05 1.4E-03 5.1E-06 4.7E-05 3.5E-04
- RECORD NUMBER 271 REPLACES RECORD NUMBER 206 ********
- TERMINATOR RECORD ENCOUNTERED -- END OF CHANGE CASE 5 USER INPUT ********
USER INPUT PROCESSING
SUMMARY
- CHANGE CASE 5 NUMBER OF RECORDS CHANGED = 10 NUMBER OF RECORDS ADDED = 0 RELEASED INVENTORY OF ALL PLUMES Co-58 4.20E+13 Co-60 3.25E+13 Kr-85 3.17E+16 Kr-85m 3.99E+15 Kr-87 1.68E+10 Kr-88 5.45E+14 Rb-86 3.36E+13 Sr-89 2.43E+14 Sr-90 2.46E+13 Sr-91 2.71E+13 Sr-92 6.55E+10 Y-90 8.59E+12 Y-91 2.08E+13 Y-92 1.40E+12 Y-93 2.50E+12 Zr-95 2.70E+13 Zr-97 7.02E+12 Nb-95 2.78E+13 Mo-99 6.02E+15 Tc-99m 5.79E+15 Ru-103 6.63E+15 Ru-105 2.55E+13 Ru-106 2.36E+15 Rh-105 2.59E+15 Sb-127 4.03E+14 Sb-129 7.35E+12 Te-127 4.33E+14 Te-127m 6.72E+13 Te-129 1.50E+14 Te-129m 2.19E+14 Te-131m 3.22E+14 Te-132 5.07E+15 I-131 4.24E+16 I-132 5.22E+15 I-133 3.23E+16 I-134 3.70E+05 I-135 2.78E+15 Xe-133 4.27E+18 Xe-135 1.17E+17 Cs-134 3.07E+15 Cs-136 8.31E+14
Calculation IP-CALC-09-00265, Rev. 0, Att. A.2, Page 25 Cs-137 1.78E+15 Ba-139 1.05E+08 Ba-140 1.81E+15 La-140 8.36E+14 La-141 7.54E+10 La-142 7.97E+06 Ce-141 2.42E+14 Ce-143 1.16E+14 Ce-144 1.96E+14 Pr-143 3.42E+13 Nd-147 9.90E+12 Np-239 2.04E+15 Pu-238 6.72E+11 Pu-239 5.76E+10 Pu-240 8.55E+10 Pu-241 1.92E+13 Am-241 2.68E+09 Cm-242 6.13E+11 Cm-244 6.58E+10
- BEGINNING OF CHANGE CASE 6 USER INPUT ********
- RELEASE DATA BLOCK *************
- SOURCE TERM NUMBER 7 OF 8 272 RDATNAM2001 'LATE LOW'
- RECORD NUMBER 272 REPLACES RECORD NUMBER 123 ********
273 RDOALARM001 2.19E+04
- RECORD NUMBER 273 REPLACES RECORD NUMBER 124 ********
274 RDNUMREL001 1
- RECORD NUMBER 274 REPLACES RECORD NUMBER 125 ********
275 RDMAXRIS001 1
- RECORD NUMBER 275 REPLACES RECORD NUMBER 126 ********
276 RDREFTIM001 0.5
- RECORD NUMBER 276 REPLACES RECORD NUMBER 127 ********
277 RDPLHEAT001 9.20E+05
- RECORD NUMBER 277 REPLACES RECORD NUMBER 128 ********
278 RDPLHITE001 30.
- RECORD NUMBER 278 REPLACES RECORD NUMBER 129 ********
279 RDPLUDUR001 8.64E+04
- RECORD NUMBER 279 REPLACES RECORD NUMBER 130 ********
280 RDPDELAY001 9.13E+04
- RECORD NUMBER 280 REPLACES RECORD NUMBER 131 ********
- Xe/Kr I Cs Te Sr Ru La Ce Ba 281 RDRELFRC001 7.0E-01 1.1E-03 7.9E-04 1.2E-03 8.7E-05 3.5E-06 2.6E-06 2.4E-05 7.4E-05
- RECORD NUMBER 281 REPLACES RECORD NUMBER 206 ********
- TERMINATOR RECORD ENCOUNTERED -- END OF CHANGE CASE 6 USER INPUT ********
USER INPUT PROCESSING
SUMMARY
- CHANGE CASE 6 NUMBER OF RECORDS CHANGED = 10 NUMBER OF RECORDS ADDED = 0
Calculation IP-CALC-09-00265, Rev. 0, Att. A.2, Page 26 RELEASED INVENTORY OF ALL PLUMES Co-58 1.05E+11 Co-60 8.12E+10 Kr-85 2.71E+16 Kr-85m 1.84E+15 Kr-87 1.64E+09 Kr-88 1.76E+14 Rb-86 6.14E+12 Sr-89 2.63E+14 Sr-90 2.67E+13 Sr-91 2.20E+13 Sr-92 2.58E+10 Y-90 9.44E+12 Y-91 1.10E+13 Y-92 7.15E+11 Y-93 9.71E+11 Zr-95 1.38E+13 Zr-97 3.04E+12 Nb-95 1.42E+13 Mo-99 1.44E+13 Tc-99m 1.39E+13 Ru-103 1.65E+13 Ru-105 3.43E+10 Ru-106 5.90E+12 Rh-105 5.98E+12 Sb-127 3.13E+14 Sb-129 3.11E+12 Te-127 3.38E+14 Te-127m 5.37E+13 Te-129 1.17E+14 Te-129m 1.75E+14 Te-131m 2.35E+14 Te-132 3.91E+15 I-131 3.09E+15 I-132 4.03E+15 I-133 2.08E+15 I-134 1.17E+03 I-135 1.34E+14 Xe-133 3.56E+18 Xe-135 6.83E+16 Cs-134 5.65E+14 Cs-136 1.51E+14 Cs-137 3.28E+14 Ba-139 3.00E+06 Ba-140 3.79E+14 La-140 1.95E+14 La-141 1.91E+10 La-142 6.81E+05 Ce-141 1.23E+14 Ce-143 5.46E+13 Ce-144 1.00E+14 Pr-143 1.78E+13 Nd-147 5.00E+12 Np-239 9.91E+14 Pu-238 3.43E+11 Pu-239 2.94E+10 Pu-240 4.37E+10 Pu-241 9.79E+12 Am-241 1.37E+09
Calculation IP-CALC-09-00265, Rev. 0, Att. A.2, Page 27 Cm-242 3.13E+11 Cm-244 3.35E+10
- BEGINNING OF CHANGE CASE 7 USER INPUT ********
- RELEASE DATA BLOCK *************
- SOURCE TERM NUMBER 8 OF 8 282 RDATNAM2001 'LATE LOWLOW'
- RECORD NUMBER 282 REPLACES RECORD NUMBER 123 ********
283 RDOALARM001 2.56E+04
- RECORD NUMBER 283 REPLACES RECORD NUMBER 124 ********
284 RDNUMREL001 1
- RECORD NUMBER 284 REPLACES RECORD NUMBER 125 ********
285 RDMAXRIS001 1
- RECORD NUMBER 285 REPLACES RECORD NUMBER 126 ********
286 RDREFTIM001 0.5
- RECORD NUMBER 286 REPLACES RECORD NUMBER 127 ********
287 RDPLHEAT001 9.20E+05
- RECORD NUMBER 287 REPLACES RECORD NUMBER 128 ********
288 RDPLHITE001 30.
- RECORD NUMBER 288 REPLACES RECORD NUMBER 129 ********
289 RDPLUDUR001 8.64E+04
- RECORD NUMBER 289 REPLACES RECORD NUMBER 130 ********
290 RDPDELAY001 1.13E+05
- RECORD NUMBER 290 REPLACES RECORD NUMBER 131 ********
- Xe/Kr I Cs Te Sr Ru La Ce Ba 291 RDRELFRC001 9.1E-01 8.1E-04 7.0E-04 7.6E-04 3.6E-05 2.1E-06 1.1E-06 1.2E-05 3.3E-05
- RECORD NUMBER 291 REPLACES RECORD NUMBER 206 ********
- TERMINATOR RECORD ENCOUNTERED -- END OF CHANGE CASE 7 USER INPUT ********
USER INPUT PROCESSING
SUMMARY
- CHANGE CASE 7 NUMBER OF RECORDS CHANGED = 10 NUMBER OF RECORDS ADDED = 0 RELEASED INVENTORY OF ALL PLUMES Co-58 6.27E+10 Co-60 4.87E+10 Kr-85 3.52E+16 Kr-85m 9.42E+14 Kr-87 8.00E+07 Kr-88 5.27E+13 Rb-86 5.39E+12 Sr-89 1.09E+14 Sr-90 1.11E+13 Sr-91 5.88E+12 Sr-92 2.28E+09 Y-90 4.36E+12 Y-91 4.66E+12 Y-92 9.41E+10 Y-93 2.72E+11 Zr-95 5.80E+12
Calculation IP-CALC-09-00265, Rev. 0, Att. A.2, Page 28 Zr-97 1.00E+12 Nb-95 5.99E+12 Mo-99 8.14E+12 Tc-99m 7.83E+12 Ru-103 9.87E+12 Ru-105 8.02E+09 Ru-106 3.54E+12 Rh-105 3.19E+12 Sb-127 1.89E+14 Sb-129 7.49E+11 Te-127 2.06E+14 Te-127m 3.40E+13 Te-129 7.24E+13 Te-129m 1.10E+14 Te-131m 1.29E+14 Te-132 2.35E+15 I-131 2.23E+15 I-132 2.42E+15 I-133 1.25E+15 I-134 7.35E+00 I-135 5.26E+13 Xe-133 4.48E+18 Xe-135 5.59E+16 Cs-134 5.00E+14 Cs-136 1.32E+14 Cs-137 2.90E+14 Ba-139 6.46E+04 Ba-140 1.67E+14 La-140 9.47E+13 La-141 2.79E+09 La-142 1.92E+04 Ce-141 6.13E+13 Ce-143 2.41E+13 Ce-144 5.01E+13 Pr-143 8.24E+12 Nd-147 2.08E+12 Np-239 4.60E+14 Pu-238 1.72E+11 Pu-239 1.47E+10 Pu-240 2.18E+10 Pu-241 4.89E+12 Am-241 5.92E+08 Cm-242 1.32E+11 Cm-244 1.42E+10 USER INPUT IS READ FROM UNIT 25 RECORD IDENTIFIER FIELDS 11 CHARACTERS LONG ARE EXPECTED.
THE FIRST 100 COLUMNS OF EACH INPUT RECORD ARE PROCESSED.
THE MAXIMUM NUMBER OF IDENTIFIER RECORDS THAT MAY BE SAVED AS THE BASE CASE IS 1000.
RECORD NUMBER RECORD
- GENERAL DESCRIPTIVE TITLE DESCRIBING THIS "EARLY" INPUT FILE 1 MIEANAM1001 'EARLY.IN, IPEC INPUT FROM THE EVACUATION TIME ESTIMATES' 2 DCF_FILE001 'DOSDATA.INP' (DCF file of MACCS 1.5.11.1)
Calculation IP-CALC-09-00265, Rev. 0, Att. A.2, Page 29
- ORGNAM ORGFLG 3 MIORGDEF001 'A-SKIN' .TRUE.
4 MIORGDEF002 'A-RED MARR' .TRUE.
5 MIORGDEF003 'A-LUNGS' .TRUE.
6 MIORGDEF004 'A-THYROIDH' .TRUE.
7 MIORGDEF005 'A-STOMACH' .TRUE.
8 MIORGDEF006 'A-LOWER LI' .FALSE. (does not contribute to early fatalities) 9 MIORGDEF007 'L-EDEWBODY' .TRUE.
10 MIORGDEF008 'L-RED MARR' .TRUE.
11 MIORGDEF009 'L-BONE SUR' .TRUE.
12 MIORGDEF010 'L-BREAST' .TRUE.
13 MIORGDEF011 'L-LUNGS' .TRUE.
14 MIORGDEF012 'L-THYROID' .TRUE.
15 MIORGDEF013 'L-LOWER LI' .TRUE.
16 MIORGDEF014 'L-BLAD WAL' .TRUE.
17 MIORGDEF015 'L-LIVER' .FALSE.
18 MIORGDEF016 'L-THYROIDH' .TRUE.
- FLAG TO INDICATE THAT THIS IS THE LAST PROGRAM IN THE SERIES TO BE RUN 19 MIENDAT2001 .FALSE. (SET THIS VALUE TO .TRUE. TO SKIP CHRONC)
- DISPERSION MODEL OPTION CODE: 1
- STRAIGHT LINE
- 2
- WIND-SHIFT WITH ROTATION
- 3
- WIND-SHIFT WITHOUT ROTATION 20 MIIPLUME001 2
- NUMBER OF FINE GRID SUBDIVISIONS USED BY THE MODEL 21 MINUMFIN001 7 (3, 5 OR 7 ALLOWED)
- LEVEL OF DEBUG OUTPUT REQUIRED, NORMAL RUNS SHOULD SPECIFY ZERO 22 MIIPRINT001 0
- LOGICAL FLAG SIGNIFYING THAT THE BREAKDOWN OF RISK BY WEATHER CATEGORY
- BIN ARE TO BE PRESENTED TO SHOW THEIR RELATIVE CONTRIBUTION TO THE MEAN
- RISBIN 23 MIRISCAT001 .FALSE.
- FLAG INDICATING IF WIND-ROSES FROM ATMOS ARE TO BE OVERRIDDEN 24 MIOVRRID001 .FALSE. (USE THE WIND ROSE CALCULATED FOR EACH WEATHER BIN)
- POPULATION DISTRIBUTION DATA BLOCK, LOADED BY INPOPU, STORED IN /POPDAT/
25 PDPOPFLG001 FILE
- PDPOPFLG001 UNIFORM
- PDIBEGIN001 1 (SPATIAL INTERVAL AT WHICH POPULATION BEGINS)
- PDPOPDEN001 50. (POPULATION DENSITY (PEOPLE PER SQUARE KILOMETER))
- SHIELDING AND EXPOSURE FACTORS, LOADED BY INDFAC, STORED IN /EADFAC/
- THREE VALUES OF EACH PROTECTION FACTOR ARE SUPPLIED,
Calculation IP-CALC-09-00265, Rev. 0, Att. A.2, Page 30
- ONE FOR EACH TYPE OF ACTIVTY:
- ACTIVITY TYPE:
- 1 - EVACUEES WHILE MOVING
- 2 - NORMAL ACTIVITY IN SHELTERING AND EVACUATION ZONE
- 3 - SHELTERED ACTIVITY
- CLOUD SHIELDING FACTOR
- SITE GG PB SEQ SUR ZION
- SHELTERING 0.7 0.5 0.65 0.6 0.5
- EVACUEES NORMAL SHELTER 26 SECSFACT001 1. 0.75 0.6
- SURRY SHELTERING VALUE
- PROTECTION FACTOR FOR INHALATION 27 SEPROTIN001 1. 0.41 0.33
- VALUES FOR NORMAL ACTIVITY AND
- SHELTERING SELECTED BY NRC STAFF
- BREATHING RATE (CUBIC METERS PER SECOND) 28 SEBRRATE001 2.66E-4 2.66E-4 2.66E-4
- SKIN PROTECTION FACTOR 29 SESKPFAC001 1.0 0.41 0.33
- VALUES FOR NORMAL ACTIVITY AND
- SHELTERING SELECTED BY NRC STAFF
- GROUND SHIELDING FACTOR
- SITE GG PB SEQ SUR ZION
- SHELTERING 0.25 0.1 0.2 0.2 0.1 30 SEGSHFAC001 0.5 0.4 0.2
- VALUE FOR NORMAL ACTIVITY SELECTED BY
- NRC STAFF
- RESUSPENSION INHALATION MODEL CONCENTRATION COEFFICIENT (/METER)
- RESCON = 1.E-4 IS APPROPRIATE FOR MECHANICAL RESUSPENSION BY VEHICLES.
- RESHAF = 2.11 DAYS CAUSES 1.E-4 TO DECAY IN ONE WEEK TO 1.E-5, THE VALUE
- OF RESCON USED IN THE FIRST TERM OF THE LONG-TERM RESUSPENSION EQUATION
- USED IN CHRONC.
31 SERESCON001 1.E-4 (RESUSPENSION IS TURNED ON)
- RESUSPENSION CONCENTRATION COEFFICIENT HALF-LIFE (SEC) 32 SERESHAF001 1.82E5 (2.11 DAYS)
- EVACUATION ZONE DATA BLOCK, LOADED BY EVNETW, STORED IN /NETWOR/, /EOPTIO/
- SPECIFIC DESCRIPTION OF THE EMERGENCY RESPONSE SCENARIO BEING USED 33 EZEANAM2001 'NO EVACUATION, RELOCATION MODELS APPLY EVERYWHE'
- THE TYPE OF WEIGHTING TO BE APPLIED TO THE EMERGENCY RESPONSE SCENARIOS
- YOU MUST SUPPLY A VALUE OF 'TIME' OR 'PEOPLE'
Calculation IP-CALC-09-00265, Rev. 0, Att. A.2, Page 31 34 EZWTNAME001 'PEOPLE'
- WEIGHTING FRACTION APPLICABLE TO THIS SCENARIO 35 EZWTFRAC001 1.00
- LAST RING IN THE MOVEMENT ZONE 36 EZLASMOV001 0 (A ZERO TURNS OFF THE EVACUATION MODEL)
- SHELTER AND RELOCATION ZONE DATA BLOCK, LOADED BY INPEMR,
- STORED IN /INPSRZ/, /RELOCA/
- DURATION OF THE EMERGENCY PHASE (SECONDS FROM PLUME ARRIVAL) 37 SRENDEMP001 604800. (ONE WEEK)
- CRITICAL ORGAN FOR RELOCATION DECISIONS 38 SRCRIORG001 'L-EDEWBODY'
- HOT SPOT RELOCATION TIME (SECONDS FROM PLUME ARRIVAL) 39 SRTIMHOT001 43200. (ONE-HALF DAY)
- NORMAL RELOCATION TIME (SECONDS FROM PLUME ARRIVAL) 40 SRTIMNRM001 86400. (ONE DAY)
- HOT SPOT RELOCATION DOSE CRITERION THRESHOLD (SIEVERTS) 41 SRDOSHOT001 0.5 (50 REM DOSE TO WHOLE BODY IN 1 WEEK TRIGGERS RELOCATION)
- NORMAL RELOCATION DOSE CRITERION THRESHOLD (SIEVERTS) 42 SRDOSNRM001 0.25 (25 REM DOSE TO WHOLE BODY IN 1 WEEK TRIGGERS RELOCATION)
- EARLY FATALITY MODEL PARAMETERS, LOADED BY INEFAT, STORED IN /EFATAL/
- NUMBER OF EARLY FATALITY EFFECTS 43 EFNUMEFA001 2
- ORGNAM EFFACA EFFACB EFFTHR 44 EFATAGRP001 'A-RED MARR' 3.8 5.0 1.5 45 EFATAGRP002 'A-LUNGS' 10.0 7.0 5.0
- EARLY INJURY MODEL PARAMETERS, LOADED BY INEINJ, STORED IN /EINJUR/
- NUMBER OF EARLY INJURY EFFECTS 46 EINUMEIN001 7
- EINAME ORGNAM EISUSC EITHRE EIFACA EIFACB 47 EINJUGRP001 'PRODROMAL VOMIT' 'A-STOMACH' 1. .5 2. 3.
Calculation IP-CALC-09-00265, Rev. 0, Att. A.2, Page 32 48 EINJUGRP002 'DIARRHEA' 'A-STOMACH' 1. 1. 3. 2.5 49 EINJUGRP003 'PNEUMONITIS' 'A-LUNGS' 1. 5. 10. 7.
50 EINJUGRP004 'SKIN ERYTHEMA' 'A-SKIN' 1. 3. 6. 5.
51 EINJUGRP005 'TRANSEPIDERMAL' 'A-SKIN' 1. 10. 20. 5.
52 EINJUGRP006 'THYROIDITIS' 'A-THYROIDH' 1. 40. 240. 2.
53 EINJUGRP007 'HYPOTHYROIDISM' 'A-THYROIDH' 1. 2. 60. 1.3
- ACUTE EXPOSURE CANCER PARAMETERS, LOADED BY INACAN STORED IN /ACANCR/.
- NUMBER OF ACUTE EXPOSURE CANCER EFFECTS 54 LCNUMACA001 7
- THRESHOLD DOSE FOR APPLYING THE DOSE DEPENDENT REDUCTION FACTOR 55 LCDDTHRE001 0.2 (LOWEST DOSE FOR WHICH DDREFA WILL BE APPLIED)
- DOSE THRESHOLD FOR LINEAR DOSE RESPONSE (Sv) 56 LCACTHRE001 0.0 (LINEAR-QUADRATIC MODEL IS NOT BEING USED)
- ACNAME ORGNAM ACSUSC DOSEFA DOSEFB CFRISK CIRISK DDREFA 57 LCANCERS001 'LEUKEMIA' 'L-RED MARR' 1.0 1.0 0.0 9.70E-3 0.0 2.0 58 LCANCERS002 'BONE' 'L-BONE SUR' 1.0 1.0 0.0 9.00E-4 0.0 2.0 59 LCANCERS003 'BREAST' 'L-BREAST' 1.0 1.0 0.0 5.40E-3 1.7E-2 1.0 60 LCANCERS004 'LUNG' 'L-LUNGS' 1.0 1.0 0.0 1.55E-2 0.0 2.0 61 LCANCERS005 'THYROID' 'L-THYROIDH' 1.0 1.0 0.0 7.20E-4 7.2E-3 1.0 62 LCANCERS006 'GI' 'L-LOWER LI' 1.0 1.0 0.0 3.36E-2 0.0 2.0 63 LCANCERS007 'OTHER' 'L-EDEWBODY' 1.0 1.0 0.0 2.76E-2 0.0 2.0
- RESULT 1 OPTIONS BLOCK, LOADED BY INOUT1, STORED IN /INOUT1/
- TOTAL NUMBER OF A GIVEN EFFECT (LATENT CANCER, EARLY DEATH, EARLY INJURY)
- NUMBER OF DESIRED RESULTS OF THIS TYPE 64 TYPE1NUMBER 4 65 TYPE1OUT001 'ERL FAT/TOTAL' 1 15 NOCCDF (0 TO 50 MILES) 66 TYPE1OUT009 'CAN FAT/TOTAL' 1 15 NOCCDF 67 TYPE1OUT019 'CAN FAT/TOTAL' 1 11 NOCCDF (0 TO 10 MILES) 68 TYPE1OUT020 'ERL FAT/TOTAL' 1 11 (0 TO 10 MILES)
- RESULT 2 OPTIONS BLOCK, LOADED BY INOUT2, STORED IN /INOUT2/
- FURTHEST DISTANCE AT WHICH A GIVEN RISK OF EARLY DEATH IS EXCEEDED.
- NUMBER OF DESIRED RESULTS OF THIS TYPE 69 TYPE2NUMBER 0
- FATALITY RISK THRESHOLD
- TYPE2OUT001 0.
- RESULT 3 OPTIONS BLOCK, LOADED BY INOUT3, STORED IN /INOUT3/
- NUMBER OF PEOPLE WHOSE DOSE TO A GIVEN ORGAN EXCEEDS A GIVEN THRESHOLD.
- NUMBER OF DESIRED RESULTS OF THIS TYPE
Calculation IP-CALC-09-00265, Rev. 0, Att. A.2, Page 33 70 TYPE3NUMBER 0
- ORGAN NAME DOSE THRESHOLD (Sv)
- TYPE3OUT001 'A-RED MARR' 1.5
- TYPE3OUT002 'A-LUNGS' 5.0
- TYPE3OUT003 'L-EDEWBODY' 0.05
- RESULT 4 OPTIONS BLOCK, LOADED BY INOUT4, STORED IN /INOUT4/
- 360 DEGREE AVERAGE RISK OF A GIVEN EFFECT AT A GIVEN DISTANCE.
- POSSIBLE TYPES OF EFFECTS ARE:
- 'ERL FAT/TOTAL'
- 'ERL INJ/INJURY NAME'
- 'CAN FAT/CANCER NAME'
- 'CAN FAT/TOTAL'
- NUMBER OF DESIRED RESULTS OF THIS TYPE 71 TYPE4NUMBER 3
- RADIAL INDEX TYPE OF EFFECT 72 TYPE4OUT001 1 'ERL FAT/TOTAL' 73 TYPE4OUT002 2 'ERL FAT/TOTAL' 74 TYPE4OUT003 3 'ERL FAT/TOTAL'
- RESULT 5 OPTIONS BLOCK, LOADED BY INOUT5, STORED IN /INOUT5/
- TOTAL POPULATION DOSE TO A GIVEN ORGAN BETWEEN TWO DISTANCES.
- NUMBER OF DESIRED RESULTS OF THIS TYPE 75 TYPE5NUMBER 1
- ORGAN I1DIS5 I2DIS5 76 TYPE5OUT001 'L-EDEWBODY' 1 15 NOCCDF (0-50 MILES)
- RESULT 6 OPTIONS BLOCK, LOADED BY INOUT6, STORED IN /INOUT6/
- CENTERLINE DOSE TO AN ORGAN VS DIST BY PATHWAY, PATHWAY NAMES ARE AS FOLLOWS:
- PATHWAY NAME:
- 'CLD' - CLOUDSHINE
- 'GRD' - GROUNDSHINE
- 'INH ACU' - "ACUTE DOSE EQUIVALENT" FROM DIRECT INHALATION OF THE CLOUD
- 'INH LIF' - "LIFETIME DOSE COMMITMENT" FROM DIRECT INHALATION OF THE CLOUD
- 'RES ACU' - "ACUTE DOSE EQUIVALENT" FROM RESUSPENSION INHALATION
- 'RES LIF' - "LIFETIME DOSE COMMITMENT" FROM RESUSPENSION INHALATION
- 'TOT ACU' - "ACUTE DOSE EQUIVALENT" FROM ALL PATHWAYS
- 'TOT LIF' - "LIFETIME DOSE COMMITMENT" FROM ALL PATHWAYS
- NUMBER OF DESIRED RESULTS OF THIS TYPE 77 TYPE6NUMBER 0
- ORGNAM PATHNM I1DIS6 I2DIS6
Calculation IP-CALC-09-00265, Rev. 0, Att. A.2, Page 34
- TYPE6OUT001 'A-RED MARR' 'TOT ACU' 1 19 (0-50 MILES)
- TYPE6OUT002 'A-LUNGS' 'TOT ACU' 1 19 (0-50 MILES)
- TYPE6OUT003 'L-EDEWBODY' 'TOT LIF' 1 26 (0-1000 MILES)
- RESULT 7 OPTIONS BLOCK, LOADED BY INOUT7, STORED IN /INOUT7/
- CENTERLINE RISK OF A GIVEN EFFECT VS DISTANCE
- NUMBER OF DESIRED RESULTS OF THIS TYPE 78 TYPE7NUMBER 0
- NAME I1DIS7 I2DIS7
- TYPE7OUT001 'ERL FAT/TOTAL' 1 19 (0-50 MILES)
- TYPE7OUT002 'CAN FAT/TOTAL' 1 26 (0-1000 MILES)
- RESULT 8 OPTIONS BLOCK, LOADED BY INOUT8, STORED IN /INOUT8/
- POPULATION WEIGHTED FATALITY RISK BETWEEN 2 DISTANCES
- NUMBER OF DESIRED RESULTS OF THIS TYPE 79 TYPE8NUMBER 2
- NAME I1DIS8 I2DIS8 80 TYPE8OUT001 'ERL FAT/TOTAL' 1 3 NOCCDF 81 TYPE8OUT002 'CAN FAT/TOTAL' 1 11 NOCCDF (0-10 MILES)
- RESULT A OPTIONS BLOCK, LOADED BY INOUTA, STORED IN /INOUTA/
- peak dose to a given organ
- NUMA 82 TYPEANUMBER 0
- ORGNAM I1DISA I2DISA
- TYPEAOUT001 'L-EDEWBODY' 1 15
- TERMINATOR RECORD ENCOUNTERED -- END OF BASE CASE USER INPUT ********
USER INPUT PROCESSING
SUMMARY
- BASE CASE NUMBER OF RECORDS READ = 341 NUMBER OF BLANK OR COMMENT RECORDS READ = 258 NUMBER OF TERMINATOR RECORDS = 1 NUMBER OF RECORDS PROCESSED = 82 NUMBER OF PROCESSED RECORDS DUPLICATED = 0 NUMBER OF PROCESSED RECORDS SORTED = 82 The list of defined organs is as follows (A- is ACUTE and L- is LIFETIME):
A-SKIN A-RED MARR
Calculation IP-CALC-09-00265, Rev. 0, Att. A.2, Page 35 A-LUNGS A-THYROIDH A-STOMACH L-EDEWBODY L-RED MARR L-BONE SUR L-BREAST L-LUNGS L-THYROID L-LOWER LI L-BLAD WAL L-THYROIDH Am using a DOSFAC/DOSFAC2/IDCF2 dose factor file READING FROM A DOSE CONVERSION FILE WITH THE FOLLOWING HEADER:
MACCS File DOSDATA.INP: Changed by D. CHANIN25-JUN-92, 09:53:47 Seven new organs added with MACCS Version 1.5.11.1 NO EVACUATION REQUESTED USING THE FOLLOWING SITE DATA FILE:
MACCS2 Site Data File for Indian Point Energy Center SITE FILE 15 SPATIAL INTERVALS 16 WIND DIRECTIONS 7 CROP CATEGORIES 4 WATER PATHWAY ISOTOPES 1 WATERSHEDS 21 ECONOMIC REGIONS SPATIAL DISTANCES KILOMETERS 0.3219 1.6093 3.2187 4.8280 6.4374 8.0467 9.6561 11.2654 12.8748 14.4841 16.0935 32.1869 48.2804 64.3739 80.4674 POPULATION
- 6. 0. 271. 2059. 2501. 909. 931. 1223.
1389. 1503. 1696. 22955. 30654. 39620. 51057.0
- 16. 7. 170. 1943. 2912. 2051. 1177. 1388.
1577. 1798. 1913. 28140. 39917. 56226. 67213.0
- 17. 193. 883. 2131. 2964. 3843. 3910. 3059.
2464. 1998. 1915. 29419. 53692. 62559. 41261.0
- 17. 364. 1275. 2132. 2977. 3453. 4507. 5282.
6140. 6960. 7279. 74856. 119073. 152175. 176338.0
- 17. 390. 1218. 2138. 2934. 3792. 4424. 5513.
5587. 7201. 8076. 118335. 156720. 200581. 208394.0
- 17. 409. 1256. 2136. 2970. 3592. 3698. 3857.
5734. 6783. 7409. 121515. 144267. 54180. 34361.0
- 17. 410. 1274. 2138. 2872. 3808. 4537. 5279.
6284. 7194. 8060. 111946. 87735. 236426. 379990.0
- 17. 360. 1268. 1645. 882. 495. 15. 1442.
948. 1911. 3214. 98326. 481703. 1380249. 1218170.0
- 17. 400. 701. 246. 124. 620. 1538. 3253.
4129. 4455. 5138. 135211. 1164596. 3732339. 3164306.0
- 17. 377. 562. 500. 1700. 2882. 3544. 4187.
4873. 5517. 6159. 202605. 395389. 922649. 1034467.0
- 17. 217. 187. 1566. 2274. 2916. 3574. 4188.
4361. 5358. 6138. 183372. 276902. 197362. 246076.0
- 9. 0. 620. 1623. 2197. 2924. 3550. 4014.
4196. 4255. 4335. 64428. 209197. 109102. 85849.0
Calculation IP-CALC-09-00265, Rev. 0, Att. A.2, Page 36
- 3. 0. 855. 1602. 2267. 2815. 2368. 1787.
1423. 1775. 2030. 32026. 50974. 61380. 57384.0
- 2. 0. 938. 1624. 2245. 1341. 1135. 1419.
1505. 1756. 2071. 32528. 54577. 57977. 29719.0
- 2. 45. 974. 1589. 1933. 972. 1140. 1351.
1541. 1781. 2093. 32572. 54557. 24046. 22317.0
- 3. 50. 809. 1051. 1587. 740. 1204. 1407.
1620. 1787. 2028. 31660. 32569. 27599. 34374.0 LAND FRACTION 0.37 0.00 0.23 0.96 0.99 0.94 0.78 0.87 0.85 0.81 0.82 0.83 0.94 0.94 0.93 0.92 0.02 0.13 0.91 0.97 0.98 1.00 1.00 0.98 0.99 0.94 0.95 0.99 0.99 0.98 1.00 0.47 0.69 1.00 0.99 1.00 0.98 0.96 0.95 1.00 0.94 0.91 0.94 0.95 0.96 1.00 0.89 0.99 1.00 0.99 0.90 0.96 0.95 0.96 0.96 0.97 0.91 0.92 0.95 0.98 1.00 0.95 0.95 1.00 0.98 0.99 0.94 0.99 0.87 0.99 0.99 0.92 0.97 0.97 0.78 1.00 1.00 0.98 1.00 0.99 0.93 0.79 0.69 0.89 0.93 0.91 0.97 0.95 0.27 0.12 1.00 1.00 0.99 1.00 0.96 0.99 0.96 0.95 0.98 0.99 0.99 0.93 0.53 0.48 0.98 1.00 0.88 0.99 0.77 0.29 0.13 0.00 0.26 0.16 0.30 0.43 0.77 0.70 0.79 0.82 1.00 0.97 0.55 0.12 0.05 0.21 0.43 0.77 0.85 0.81 0.83 0.84 0.87 0.81 0.59 1.00 0.92 0.44 0.31 0.75 0.99 0.99 0.99 1.00 1.00 1.00 0.99 0.99 0.93 0.92 1.00 0.53 0.18 0.96 1.00 1.00 1.00 0.99 0.89 0.97 0.99 0.98 0.93 0.90 0.94 0.52 0.00 0.64 1.00 0.97 1.00 0.99 0.95 0.91 0.92 0.94 0.94 0.93 0.97 0.94 0.19 0.00 0.88 0.99 1.00 1.00 1.00 0.98 0.86 0.95 0.97 0.97 0.98 0.97 0.97 0.13 0.00 0.96 1.00 1.00 0.99 0.94 0.99 0.91 0.94 0.99 0.98 0.99 0.97 0.95 0.14 0.14 1.00 0.98 0.99 0.98 0.94 0.94 0.93 0.95 1.00 0.98 0.99 0.99 0.96 0.20 0.16 0.83 0.57 0.65 0.75 0.99 0.98 0.98 0.95 0.97 0.96 0.96 0.99 0.96 REGION INDEX 202120202014141414131406060606 202120202014141414141414060606 202020202020201414141414060303 202020202020202020202020010104 202020202020202020202020010104 202020202020202020202020010117 202020202020202020202020011217 202020202020212020202020201212 202020202116161616161616021511 202020161616161616161602020510 202016161616161616161616080707 202116161616161616161613080909 202116161616131313131313130909 202116161613131313131313131318 201616161613131313131313131818 201616162013131313131313191919 WATERSHED INDEX 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
Calculation IP-CALC-09-00265, Rev. 0, Att. A.2, Page 37 CROP SEASON AND SHARE 1 PASTURE 90. 270. 0.0162 2 STORED FORAGE 150. 240. 0.0480 3 GRAINS 150. 240. 0.0079 4 GRN LEAFY VEGETABLES 150. 240. 0.0005 5 OTHER FOOD CROPS 150. 240. 0.0036 6 LEGUMES AND SEEDS 150. 240. 0.0002 7 ROOTS AND TUBERS 150. 240. 0.0018 WATERSHED DEFINITION -- INITIAL AND ANNUAL WASHOFF AND INGESTION FACTORS 1 Sr-89 5.00E-06 2 Sr-90 5.00E-06 3 Cs-134 5.00E-06 4 Cs-137 5.00E-06 REGIONAL ECONOMIC DATA 01 FAIRFIELD 0.032 .008 5831.0 66592.0 287881.0 02 BERGEN 0.009 .000 14568.0 124496.0 262186.0 03 LITCHFIELD 0.159 .371 795.0 22373.0 186016.0 04 NEWHAVEN 0.067 .029 5439.0 36942.0 192427.0 05 ESSEX 0.002 .000 11903.0 120139.0 197400.0 06 DUTCHESS 0.219 .207 698.0 16206.0 169417.0 07 MORRIS 0.057 .006 6005.0 67365.0 277661.0 08 PASSAIC 0.013 .000 9836.0 81944.0 161864.0 09 SUSSEX 0.226 .311 483.0 18496.0 165741.0 10 UNION 0.003 .000 91646.0 243939.0 209708.0 11 KINGS 0.000 .000 0.0 0.0 123701.0 12 NASSAU 0.006 .000 18237.0 88422.0 239932.0 13 ORANGE 0.207 .288 1516.0 13148.0 148873.0 14 PUTNAM 0.045 .000 892.0 24525.0 180274.0 15 QUEENS 0.000 .000 0.0 0.0 226728.0 16 ROCKLAND 0.011 .047 6365.0 65755.0 203359.0 17 SUFFOLK 0.058 .000 14567.0 54566.0 192471.0 18 SULLIVAN 0.103 .233 1466.0 7911.0 139374.0 19 ULSTER 0.116 .043 1019.0 9908.0 138739.0 20 WESTCHESTR 0.036 .009 2206.0 39116.0 263389.0 21 WATER 0.000 .000 0.0 0.0 0.0 POPULATION
>>The Record Identifier TYPEBNUMBER was not found:
>>Type B results not being generated USER INPUT IS READ FROM UNIT 26 RECORD IDENTIFIER FIELDS 11 CHARACTERS LONG ARE EXPECTED.
THE FIRST 100 COLUMNS OF EACH INPUT RECORD ARE PROCESSED.
THE MAXIMUM NUMBER OF IDENTIFIER RECORDS THAT MAY BE SAVED AS THE BASE CASE IS 1000.
RECORD NUMBER RECORD
- GENERAL DESCRIPTIVE TITLE DESCRIBING THIS "CHRONC" INPUT FILE 1 CHCHNAME001 'CHRONC.IN - IPEC, "New" COMIDA2-Based Food Model'
- EMERGENCY RESPONSE COST DATA BLOCK
- DAILY COST FOR A PERSON WHO IS EVACUATED (DOLLARS/PERSON-DAY) 2 CHEVACST001 46.7 (INCLUDES FOOD AND HOUSING COSTS BUT NOT LOST INCOME)
Calculation IP-CALC-09-00265, Rev. 0, Att. A.2, Page 38
- DAILY COST FOR A PERSON WHO IS RELOCATED (DOLLARS/PERSON-DAY) 3 CHRELCST001 46.7 (INCLUDES FOOD AND HOUSING COSTS BUT NOT LOST INCOME)
- LONG TERM PROTECTIVE ACTION DATA BLOCK
- Duration of the intermediate phase period--at version 1.11c TMIPND is no
- longer processed. The new input variable DUR_INTPHAS is the period's
- duration, not the time after plume arrival at which the period ends.
4 DUR_INTPHAS 0.0 (in seconds) (no intermediate phase)
- LONG-TERM PHASE DOSE PROJECTION PERIOD, THE DURATION OF THE EXPOSURE
- PERIOD OVER WHICH THE LONG-TERM DOSE CRITERION IS EVALUATED (SECONDS) 5 CHTMPACT001 1.58E8 (5 YEARS)
- DOSE CRITERION FOR INTERMEDIATE PHASE RELOCATION (Sv) 6 CHDSCRTI001 1.0E5 (NO INTERMEDIATE PHASE RELOCATION)
- DOSE CRITERION FOR LONG-TERM PHASE RELOCATION (Sv) 7 CHDSCRLT001 0.04
- CRITICAL ORGAN NAME FOR LONG-TERM ACTIONS 8 CHCRTOCR001 'L-EDEWBODY'
- Long Term Exposure Period Previously permanently set to:
- one million years = 3.15 E13 seconds
- MACCS2 allowable range is 3.15E7 to 1.E10 9 CHEXPTIM001 9.45E8
- DECONTAMINATION PLAN DATA BLOCK
- NUMBER OF LEVELS OF DECONTAMINATION 10 CHLVLDEC001 2
- DECONTAMINATION TIMES CORRESPONDING TO THE LVLDEC LEVELS OF DECONTAMINATION
- (SECONDS) 11 CHTIMDEC001 5.184E6 1.0368E7 (60, 120 DAYS)
- DOSE REDUCTION FACTORS CORRESPONDING TO THE LVLDEC LEVELS OF DECONTAMINATION 12 CHDSRFCT001 3. 15.
- COST OF FARM DECONTAMINATION PER FARMLAND UNIT AREA (DOLLARS/HECTARE)
- FOR THE VARIOUS LEVELS OF DECONTAMINATION 13 CHCDFRM0001 972. 2160.
- COST OF NONFARM DECONTAMINATION PER RESIDENT PERSON (DOLLARS/PERSON)
- FOR THE VARIOUS LEVELS OF DECONTAMINATION
Calculation IP-CALC-09-00265, Rev. 0, Att. A.2, Page 39 14 CHCDNFRM001 5184. 13824.
- FRACTION OF FARMLAND DECONTAMINATION COST DUE TO LABOR
- FOR THE VARIOUS DECONTAMINATION LEVELS 15 CHFRFDL0001 .3 .35
- FRACTION OF NON-FARM DECONTAMINATION COST DUE TO LABOR
- FOR THE VARIOUS DECONTAMINATION LEVELS 16 CHFRNFDL001 .7 .5
- FRACTION OF TIME WORKERS IN FARM AREAS SPEND IN CONTAMINATED AREAS
- FOR THE VARIOUS DECONTAMINATION LEVELS 17 CHTFWKF0001 .10 .33
- FRACTION OF TIME WORKERS IN NON-FARM AREAS SPEND IN CONTAMINATED AREAS
- FOR THE VARIOUS DECONTAMINATION LEVELS 18 CHTFWKNF001 .33 .33
- AVERAGE COST OF DECONTAMINATION LABOR (DOLLARS/MAN-YEAR) 19 CHDLBCST001 60480.
- INTERDICTION COST DATA BLOCK
- DEPRECIATION (DETERIORATION) RATE DURING INTERDICTION PERIOD (PER YEAR) 20 CHDPRATE001 .20 (VALUE OBTAINED FROM WASH-1400, APPENDIX 6)
- INVESTMENT INCOME RETURN (DISCOUNT RATE) DURING INTERDICTION PERIOD (PER YEAR)
- THIS VALUE SHOULD BE DERIVED AS A REAL RETURN RATE ADJUSTED FOR INFLATION 21 CHDSRATE001 .12 (VALUE OBTAINED FROM WASH-1400, APPENDIX 6)
- POPULATION RELOCATION COST (DOLLARS/PERSON):
- ALTERNATIVE HOUSING, MOVING COSTS, AND LOST INCOME FOR PEOPLE IN
- AREAS WHICH REQUIRE DECONTAMINATION, INTERDICTION, OR CONDEMNATION 22 CHPOPCST001 8640.
- GROUNDSHINE WEATHERING DEFINITION DATA BLOCK
- NUMBER OF TERMS IN THE GROUNDSHINE WEATHERING RELATIONSHIP (EITHER 1 OR 2) 23 CHNGWTRM001 2
- GROUNDSHINE WEATHERING COEFFICIENTS 24 CHGWCOEF001 0.5 0.5 (JON HELTON)
- HALF LIVES CORRESPONDING TO THE GROUNDSHINE WEATHERING COEFFICIENTS (S) 25 CHTGWHLF001 1.6E7 2.8E9 (JON HELTON)
- RESUSPENSION WEATHERING DEFINITION DATA BLOCK
Calculation IP-CALC-09-00265, Rev. 0, Att. A.2, Page 40
- NUMBER OF TERMS IN THE RESUSPENSION WEATHERING RELATIONSHIP 26 CHNRWTRM001 3
- RESUSPENSION CONCENTRATION COEFFICIENTS (/ METER)
- RELATIONSHIP BETWEEN GROUND CONCENTRATION AND INSTANTANEOUS AIR CONC.
27 CHRWCOEF001 1.0E-5 1.0E-7 1.0E-9 (VALUES HERE SELECTED BY JON HELTON)
- HALF-LIVES CORRESPONDING TO THE RESUSPENSION CONCENTRATION COEFFICIENTS (S) 28 CHTRWHLF001 1.6E7 1.6E8 1.6E9 (6 MONTHS, 5 YEARS, 50 YEARS)
- SITE REGION DESCRIPTION DATA BLOCK
- FRACTION OF AREA THAT IS LAND IN THE REGION 29 CHFRACLD001 0.95 (ROUGH GUESS VALUE, SITE FILE OVERRIDES THIS VALUE)
- FRACTION OF LAND DEVOTED TO FARMING IN THE REGION 30 CHFRCFRM001 0.382 (VIRGINIA STATE VALUE, SITE FILE OVERRIDES THIS VALUE)
- AVERAGE VALUE OF ANNUAL FARM PRODUCTION IN THE REGION (DOLLARS/HECTARE)
- (CASH RECEIPTS FROM FARMING PLUS VALUE OF HOME CONSUMPTION)/(LAND IN FARMS) 31 CHFRMPRD001 371.0 (VIRGINIA STATE VALUE, SITE FILE OVERRIDES THIS VALUE)
- FRACTION OF FARM PRODUCTION RESULTING FROM DAIRY PRODUCTION IN THE REGION
- (VALUE OF MILK PRODUCED)/(CASH RECEIPTS FROM FARMING PLUS HOME CONSUMPTION) 32 CHDPFRCT001 0.198 (VIRGINIA STATE VALUE, SITE FILE OVERRIDES THIS VALUE)
- VALUE OF FARM WEALTH (DOLLARS/HECTARE)
- (AVERAGE VALUE PER HECTARE OF FARM LAND AND BUILDINGS TO 100 MILES) 33 CHVALWF0001 50071.
- FRACTION OF FARM WEALTH IN IMPROVEMENTS FOR THE REGION 34 CHFRFIM0001 0.25
- NON-FARM WEALTH, PROPERTY AND IMPROVEMENTS FOR THE REGION (DOLLARS/PERSON)
- THE VALUE OF ALL RESIDENTIAL, BUSINESS, AND PUBLIC ASSETS WHICH WOULD BE
- LOST IN THE EVENT OF PERMANENT INTERDICTION (CONDEMNATION) OF THE AREA 35 CHVALWNF001 208838.
- FRACTION OF NON-FARM WEALTH IN IMPROVEMENTS FOR THE REGION 36 CHFRNFIM001 0.8 37 CHFDPATH001 'NEW'
- name of the COMIDA2 binary output file 38 BIN_FILE001 'SAMP_A.BIN' (revised data file of 8/12/95)
- Dose limits triggering first year crop disposal of the separate
Calculation IP-CALC-09-00265, Rev. 0, Att. A.2, Page 41
- milk and non-milk components of the diet, corresponding in purpose,
- more or less, to the MACCS 1.5 input variables PSCMLK and PSCOTH
- For NUREG-1150 calculations, the maximum allowable ground concentrations for
- production of milk and non-milk crops contaminated by an accident occurring
- in the growing season were derived based on an assumed maximum allowable
- the prior results, it is being assumed, for simplicity, that milk and
- non-milk crops contribute equally to the first year dose. Thus, the 5 rem
- effective dose limit used in NUREG-1150 is equally split between milk and
- thyroid limit is split into 7.5 and 7.5 rem for the milk and non-milk
- portions of the diet.
- effective thyroid (doses in sieverts) 39 DOSEMILK001 0.025 0.075 40 DOSEOTHR001 0.025 0.075
- Annual dose limits for the subsequent year's (i.e., after the first year)
- interdiction of BOTH the milk and non-milk (combined) components of the diet
- Note: the long-term food critera, GCMAXR, used for NUREG-1150 wre based on
- an ingestion dose integrated from zero to infinity. It is not possible to
- translate those parameter values into corresponding annual dose limits, as is
- required by the COMIDA2-based food model. The "total" dose limits used in
- NUREG-1150 for "root uptake", 0.5 rem effective and 1.5 rem thyroid, are used
- here as annual dose limits for interdiction of food production in years the
- years subsequent to the accident.
- effective thyroid (doses in sieverts) 41 DOSELONG001 0.005 0.015
- NUMBER OF NUCLIDES IN THE WATER INGESTION PATHWAY MODEL 42 CHNUMWPI001 4
- TABLE OF NUCLIDE DEFINITIONS IN THE WATER INGESTION PATHWAY MODEL
- IF A SITE DATA FILE IS DEFINED, THE DATA DEFINING THE WATERSHED INGESTION
- FACTOR IS SUPERSEDED BY THE CORRESPONDING DATA IN THE SITE DATA FILE
- INITIAL ANNUAL INGESTION FACTOR
- WATER WASHOFF WASHOFF ((Bq INGESTED)/
- NUCLIDE FRACTION RATE (Bq IN WATER))
- NAMWPI WSHFRI WSHRTA WINGF 43 CHWTRISO001 Sr-89 0.01 0.004 5.0E-6 44 CHWTRISO002 Sr-90 0.01 0.004 5.0E-6 45 CHWTRISO003 Cs-134 0.005 0.001 5.0E-6 46 CHWTRISO004 Cs-137 0.005 0.001 5.0E-6
- SPECIAL OPTIONS DATA BLOCK
- DETAILED PRINT OPTION CONTROL SWITCHES, LOOK AT THE CODE BEFORE TURNING ON!!
- KSWDSC 47 CHKSWTCH001 0
Calculation IP-CALC-09-00265, Rev. 0, Att. A.2, Page 42
- DEFINE THE TYPE 9 RESULTS
- LONG-TERM POPULATION DOSE IN A GIVEN REGION BROKEN DOWN BY THE 12 PATHWAYS
- NUMBER OF RESULTS OF THIS TYPE THAT ARE BEING REQUESTED
- FOR EACH RESULT YOU REQUEST, THE CODE WILL PRODUCE A SET OF 12 48 TYPE9NUMBER 1 (UP TO 10 ALLOWED)
- ORGNAM INNER OUTER 49 TYPE9OUT001 'L-EDEWBODY' 1 15 (0-50 MILES)
- ECONOMIC COST RESULTS IN A REGION BROKEN DOWN BY 12 TYPES OF COSTS
- NUMBER OF RESULTS OF THIS TYPE THAT ARE BEING REQUESTED
- FOR EACH RESULT YOU REQUEST, THE CODE WILL PRODUCE A SET OF 12 50 TYP10NUMBER 1 (UP TO 10 ALLOWED)
- INNER OUTER 51 TYP10OUT001 1 15 (0-50 MILES)
- DEFINE A FLAG THAT CONTROLS THE PRODUCTION OF THE ACTION DISTANCE RESULTS
- SPECIFYING A VALUE OF .TRUE. TURNS ON ALL 8 OF THE ACTION DISTANCE RESULTS,
- A VALUE OF .FALSE. WILL ELIMINATE THE ACTION DISTANCE RESULTS FROM THE OUTPUT.
52 TYP11FLAG11 .FALSE.
- IMPACTED AREA/POPULATION RESULTS IN A REGION BROKEN DOWN BY 6 TYPES OF IMPACTS
- NUMBER OF RESULTS OF THIS TYPE THAT ARE BEING REQUESTED
- FOR EACH RESULT YOU REQUEST, THE CODE WILL PRODUCE A SET OF 8 53 TYP12NUMBER 0 (UP TO 10 ALLOWED)
- INNER OUTER
- TYP12OUT001 1 15 (0-50 MILES)
- Maximal annual food ingestion dose to an individual, requested by IXOT13
- This result is calculated after accounting for temporary or
- permanent interdiction. It is only available for the "new" food model.
- NUMBER OF RESULTS OF THIS TYPE THAT ARE BEING REQUESTED 54 TYP13NUMBER 0 (UP TO 10 ALLOWED)
- IRAD13 is the radial spatial interval at which results are requested
- ORGN13 is the name of the organ for which results are requested
- (allowable values for ORGN13 are 'EFFECTIVE' or 'THYROID')
- IRAD13 ORGN13
- TYP13OUT001 2 EFFECTIVE
Calculation IP-CALC-09-00265, Rev. 0, Att. A.2, Page 43
- TYP13OUT002 4 EFFECTIVE
- TYP13OUT003 6 EFFECTIVE
- TYP13OUT004 8 EFFECTIVE
- TYP13OUT005 10 EFFECTIVE
- TYP13OUT006 12 EFFECTIVE
- TYP13OUT007 15 EFFECTIVE
- TYP13OUT008 2 THYROID
- TYP13OUT009 4 THYROID
- TYP13OUT010 6 THYROID
- TYP13OUT011 8 THYROID
- TYP13OUT012 10 THYROID
- TYP13OUT013 12 THYROID
- TYP13OUT014 15 THYROID
- TERMINATOR RECORD ENCOUNTERED -- END OF BASE CASE USER INPUT ********
USER INPUT PROCESSING
SUMMARY
- BASE CASE NUMBER OF RECORDS READ = 318 NUMBER OF BLANK OR COMMENT RECORDS READ = 263 NUMBER OF TERMINATOR RECORDS = 1 NUMBER OF RECORDS PROCESSED = 54 NUMBER OF PROCESSED RECORDS DUPLICATED = 0 NUMBER OF PROCESSED RECORDS SORTED = 54 COMIDA2 binary file header =
COMIDA2 01/14/2004 13:06:02 Version 1.11.1, 01/12/2004 COMIDA2 descriptive title =
MACCS File DOSDATA.INP: Changed by D. CHANIN25-JUN-92, 09:53:47 Seven new organs added with MACCS Version 1.5.11.1 A SITE DATA FILE IS BEING USED FOR BOTH "EARLY" AND "CHRONC" 7 CANCER EFFECTS ARE DEFINED IN THE MODEL.
INDEX CANCER EFFECT ORGAN ALPHA BETA CFRISK CIRISK 1 LEUKEMIA L-RED MARR 1.000E+00 0.000E+00 9.700E-03 0.000E+00 2 BONE L-BONE SUR 1.000E+00 0.000E+00 9.000E-04 0.000E+00 3 BREAST L-BREAST 1.000E+00 0.000E+00 5.400E-03 1.700E-02 4 LUNG L-LUNGS 1.000E+00 0.000E+00 1.550E-02 0.000E+00 5 THYROID L-THYROIDH 1.000E+00 0.000E+00 7.200E-04 7.200E-03 6 GI L-LOWER LI 1.000E+00 0.000E+00 3.360E-02 0.000E+00 7 OTHER L-EDEWBODY 1.000E+00 0.000E+00 2.760E-02 0.000E+00 TIME OF HOTSPOT RELOCATION IS 4.3200E+04.
TIME OF NORMAL RETURN IS 8.640E+04 AND THE EMERGENCY PHASE ENDS AT 6.048E+05.
GROUNDSHINE SHIELDING FACTOR = 0.400 RESUSPENSION PROTECTION FACTOR = 0.410 BREATHING RATE (CUBIC M/S) = 2.660E-04
Calculation IP-CALC-09-00265, Rev. 0, Att. A.2, Page 44 DISPERSION MODEL FLAG IS 2 WINDROSE PROBABILITIES BY WIND DIRECTION AND MET BIN NUMBER BIN 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 1 0.0826 0.0092 0.0092 0.0917 0.0826 0.1284 0.1651 0.1743 0.0917 0.0000 0.0092 0.0000 0.0000 0.0092 0.0000 0.1468 2 0.0659 0.0330 0.0220 0.0000 0.0220 0.0440 0.1538 0.0769 0.2747 0.0549 0.0000 0.0000 0.0000 0.0000 0.0000 0.2527 3 0.1147 0.0734 0.0550 0.0321 0.0092 0.0138 0.0046 0.0229 0.0321 0.0642 0.0596 0.0642 0.1147 0.1009 0.1422 0.0963 4 0.1583 0.0922 0.0414 0.0487 0.0472 0.0392 0.0465 0.0632 0.1089 0.1126 0.0712 0.0428 0.0196 0.0116 0.0254 0.0712 5 0.1236 0.0471 0.0206 0.0330 0.0671 0.1065 0.0989 0.1024 0.1919 0.1254 0.0288 0.0041 0.0018 0.0000 0.0029 0.0459 6 0.0750 0.0200 0.0069 0.0110 0.0399 0.1287 0.1913 0.1115 0.2230 0.1383 0.0172 0.0007 0.0000 0.0000 0.0007 0.0358 7 0.0548 0.0205 0.0137 0.0000 0.0205 0.0342 0.2740 0.0685 0.3425 0.1438 0.0000 0.0000 0.0000 0.0000 0.0000 0.0274 8 0.0000 0.0000 0.0000 0.0000 0.2000 0.0000 0.0000 0.2000 0.4000 0.2000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 9 0.1179 0.0866 0.0755 0.0368 0.0221 0.0276 0.0239 0.0313 0.0810 0.1087 0.0608 0.0589 0.0405 0.0718 0.0810 0.0755 10 0.1882 0.0935 0.0646 0.0256 0.0167 0.0067 0.0089 0.0100 0.0468 0.1904 0.1626 0.0512 0.0245 0.0100 0.0134 0.0869 11 0.2271 0.0542 0.0034 0.0034 0.0068 0.0068 0.0034 0.0136 0.0441 0.4237 0.1627 0.0034 0.0000 0.0000 0.0000 0.0475 12 0.2982 0.0526 0.0351 0.0000 0.0000 0.0175 0.0000 0.0175 0.2456 0.2105 0.0351 0.0000 0.0000 0.0000 0.0000 0.0877 13 0.0506 0.0169 0.0393 0.0000 0.0225 0.0337 0.0449 0.0899 0.2247 0.2079 0.0730 0.0562 0.0337 0.0112 0.0449 0.0506 14 0.0167 0.0083 0.0083 0.0042 0.0083 0.0000 0.0000 0.0042 0.0542 0.6750 0.1708 0.0333 0.0042 0.0042 0.0000 0.0083 15 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.7069 0.2759 0.0000 0.0000 0.0000 0.0000 0.0172 16 0.1429 0.0000 0.0000 0.0000 0.0000 0.1429 0.0000 0.0000 0.0000 0.4286 0.2857 0.0000 0.0000 0.0000 0.0000 0.0000 17 0.1472 0.0534 0.0245 0.0159 0.0101 0.0253 0.0108 0.0260 0.1212 0.2222 0.0765 0.0404 0.0382 0.0397 0.0339 0.1147 18 0.1472 0.0534 0.0245 0.0159 0.0101 0.0253 0.0108 0.0260 0.1212 0.2222 0.0765 0.0404 0.0382 0.0397 0.0339 0.1147 19 0.1472 0.0534 0.0245 0.0159 0.0101 0.0253 0.0108 0.0260 0.1212 0.2222 0.0765 0.0404 0.0382 0.0397 0.0339 0.1147 20 0.1472 0.0534 0.0245 0.0159 0.0101 0.0253 0.0108 0.0260 0.1212 0.2222 0.0765 0.0404 0.0382 0.0397 0.0339 0.1147 21 0.1472 0.0534 0.0245 0.0159 0.0101 0.0253 0.0108 0.0260 0.1212 0.2222 0.0765 0.0404 0.0382 0.0397 0.0339 0.1147 22 0.1472 0.0534 0.0245 0.0159 0.0101 0.0253 0.0108 0.0260 0.1212 0.2222 0.0765 0.0404 0.0382 0.0397 0.0339 0.1147 23 0.1472 0.0534 0.0245 0.0159 0.0101 0.0253 0.0108 0.0260 0.1212 0.2222 0.0765 0.0404 0.0382 0.0397 0.0339 0.1147 24 0.1472 0.0534 0.0245 0.0159 0.0101 0.0253 0.0108 0.0260 0.1212 0.2222 0.0765 0.0404 0.0382 0.0397 0.0339 0.1147 25 0.1472 0.0534 0.0245 0.0159 0.0101 0.0253 0.0108 0.0260 0.1212 0.2222 0.0765 0.0404 0.0382 0.0397 0.0339 0.1147 26 0.1472 0.0534 0.0245 0.0159 0.0101 0.0253 0.0108 0.0260 0.1212 0.2222 0.0765 0.0404 0.0382 0.0397 0.0339 0.1147 27 0.1472 0.0534 0.0245 0.0159 0.0101 0.0253 0.0108 0.0260 0.1212 0.2222 0.0765 0.0404 0.0382 0.0397 0.0339 0.1147 28 0.1472 0.0534 0.0245 0.0159 0.0101 0.0253 0.0108 0.0260 0.1212 0.2222 0.0765 0.0404 0.0382 0.0397 0.0339 0.1147 29 0.1472 0.0534 0.0245 0.0159 0.0101 0.0253 0.0108 0.0260 0.1212 0.2222 0.0765 0.0404 0.0382 0.0397 0.0339 0.1147 30 0.1472 0.0534 0.0245 0.0159 0.0101 0.0253 0.0108 0.0260 0.1212 0.2222 0.0765 0.0404 0.0382 0.0397 0.0339 0.1147 31 0.1472 0.0534 0.0245 0.0159 0.0101 0.0253 0.0108 0.0260 0.1212 0.2222 0.0765 0.0404 0.0382 0.0397 0.0339 0.1147 32 0.1472 0.0534 0.0245 0.0159 0.0101 0.0253 0.0108 0.0260 0.1212 0.2222 0.0765 0.0404 0.0382 0.0397 0.0339 0.1147 33 0.1472 0.0534 0.0245 0.0159 0.0101 0.0253 0.0108 0.0260 0.1212 0.2222 0.0765 0.0404 0.0382 0.0397 0.0339 0.1147 34 0.1472 0.0534 0.0245 0.0159 0.0101 0.0253 0.0108 0.0260 0.1212 0.2222 0.0765 0.0404 0.0382 0.0397 0.0339 0.1147 35 0.1472 0.0534 0.0245 0.0159 0.0101 0.0253 0.0108 0.0260 0.1212 0.2222 0.0765 0.0404 0.0382 0.0397 0.0339 0.1147 36 0.1472 0.0534 0.0245 0.0159 0.0101 0.0253 0.0108 0.0260 0.1212 0.2222 0.0765 0.0404 0.0382 0.0397 0.0339 0.1147 37 0.1472 0.0534 0.0245 0.0159 0.0101 0.0253 0.0108 0.0260 0.1212 0.2222 0.0765 0.0404 0.0382 0.0397 0.0339 0.1147 38 0.1472 0.0534 0.0245 0.0159 0.0101 0.0253 0.0108 0.0260 0.1212 0.2222 0.0765 0.0404 0.0382 0.0397 0.0339 0.1147 39 0.1472 0.0534 0.0245 0.0159 0.0101 0.0253 0.0108 0.0260 0.1212 0.2222 0.0765 0.0404 0.0382 0.0397 0.0339 0.1147 40 0.1472 0.0534 0.0245 0.0159 0.0101 0.0253 0.0108 0.0260 0.1212 0.2222 0.0765 0.0404 0.0382 0.0397 0.0339 0.1147 41 0.1279 0.0557 0.0301 0.0255 0.0346 0.0587 0.0717 0.0627 0.1402 0.1744 0.0677 0.0267 0.0182 0.0166 0.0209 0.0686 Processing a Site Data File with Header: MACCS2 Site Data File for Indian Point Energy Center SITE FILE
Calculation IP-CALC-09-00265, Rev. 0, Att. A.2, Page 45 THIS PROGRAM CURRENTLY ALLOWS THE GENERATION OF UP TO 394 RESULTS YOU HAVE REQUESTED 10 RESULTS FROM "EARLY" COMPOSED OF:
4 RESULTS OF TYPE 1 0 RESULTS OF TYPE 2 0 RESULTS OF TYPE 3 3 RESULTS OF TYPE 4 1 RESULTS OF TYPE 5 0 RESULTS OF TYPE 6 0 RESULTS OF TYPE 7 2 RESULTS OF TYPE 8 0 RESULTS OF TYPE A 0 RESULTS OF TYPE B YOU HAVE REQUESTED 30 RESULTS FROM "CHRONC" COMPOSED OF:
17 RESULTS OF TYPE 9 13 RESULTS OF TYPE 10 0 RESULTS OF TYPE 11 0 RESULTS OF TYPE 12 0 RESULTS OF TYPE 13 TRIAL DAY HOUR BIN PRBMET 1 152 16 1 3.11E-03
Calculation IP-CALC-09-00265, Rev. 0, Att. A.2, Page 46 WARNING!! WARNING!! WARNING!! WARNING!!
THE TOTAL RELEASE DURATION EXCEEDS 20 HOURS.
THIS MAY CAUSE ERRONEOUS RESULTS TO BE PRODUCED.
WARNING!! WARNING!! WARNING!! WARNING!!
Calculation IP-CALC-09-00265, Rev. 0, Att. A.2, Page 47 WARNING!! WARNING!! WARNING!! WARNING!!
A 10 HOUR RELEASE DURATION IS BEING USED BY ATMOS FOR CALCULATING THE EXPANSION FACTOR OF PLUME # 1 INSTEAD OF THE USER-SUPPLIED 24.00 HOURS WARNING!! WARNING!! WARNING!! WARNING!!
For Julian Day 152, selecting COMIDA2 results # 4 of 9 2 156 2 16 2.00E-04 For Julian Day 156, selecting COMIDA2 results # 4 of 9 3 156 14 2 2.60E-03 For Julian Day 156, selecting COMIDA2 results # 4 of 9 4 158 4 28 1.23E-03 For Julian Day 158, selecting COMIDA2 results # 4 of 9 5 158 14 23 1.86E-03 For Julian Day 158, selecting COMIDA2 results # 4 of 9 6 163 16 27 5.42E-04 For Julian Day 163, selecting COMIDA2 results # 4 of 9 7 163 17 25 4.00E-04 For Julian Day 163, selecting COMIDA2 results # 4 of 9 8 163 18 24 1.43E-04 For Julian Day 163, selecting COMIDA2 results # 4 of 9 9 163 22 18 1.34E-03 For Julian Day 163, selecting COMIDA2 results # 4 of 9 10 164 11 21 5.76E-03 For Julian Day 164, selecting COMIDA2 results # 4 of 9 11 165 13 28 1.23E-03 For Julian Day 165, selecting COMIDA2 results # 4 of 9 12 165 17 26 2.00E-04 For Julian Day 165, selecting COMIDA2 results # 4 of 9 13 165 20 24 1.43E-04 For Julian Day 165, selecting COMIDA2 results # 4 of 9 14 166 5 3 6.22E-03 For Julian Day 166, selecting COMIDA2 results # 4 of 9 15 166 12 4 3.93E-02 For Julian Day 166, selecting COMIDA2 results # 4 of 9 16 169 4 9 1.55E-02 For Julian Day 169, selecting COMIDA2 results # 5 of 9 17 170 10 30 1.14E-04 For Julian Day 170, selecting COMIDA2 results # 5 of 9 18 179 8 40 1.14E-03 For Julian Day 179, selecting COMIDA2 results # 5 of 9 19 179 12 38 1.71E-04 For Julian Day 179, selecting COMIDA2 results # 5 of 9 20 179 13 37 2.85E-04 For Julian Day 179, selecting COMIDA2 results # 5 of 9 21 179 14 35 8.56E-04 For Julian Day 179, selecting COMIDA2 results # 5 of 9 22 180 1 15 1.66E-03 For Julian Day 180, selecting COMIDA2 results # 5 of 9 23 180 21 10 2.56E-02 For Julian Day 180, selecting COMIDA2 results # 5 of 9 24 184 4 14 6.85E-03 For Julian Day 184, selecting COMIDA2 results # 5 of 9 25 193 9 6 4.15E-02 For Julian Day 193, selecting COMIDA2 results # 6 of 9 26 196 13 27 5.42E-04 For Julian Day 196, selecting COMIDA2 results # 6 of 9
Calculation IP-CALC-09-00265, Rev. 0, Att. A.2, Page 48 27 196 14 26 2.00E-04 For Julian Day 196, selecting COMIDA2 results # 6 of 9 28 197 3 24 1.43E-04 For Julian Day 197, selecting COMIDA2 results # 6 of 9 29 197 6 30 1.14E-04 For Julian Day 197, selecting COMIDA2 results # 6 of 9 30 197 7 29 5.99E-04 For Julian Day 197, selecting COMIDA2 results # 6 of 9 31 197 14 25 4.00E-04 For Julian Day 197, selecting COMIDA2 results # 6 of 9 32 199 24 34 8.28E-04 For Julian Day 199, selecting COMIDA2 results # 6 of 9 33 200 2 33 4.00E-04 For Julian Day 200, selecting COMIDA2 results # 6 of 9 34 200 6 31 2.00E-04 For Julian Day 200, selecting COMIDA2 results # 6 of 9 35 200 7 30 1.14E-04 For Julian Day 200, selecting COMIDA2 results # 6 of 9 36 203 12 28 1.23E-03 For Julian Day 203, selecting COMIDA2 results # 6 of 9 37 206 2 15 1.66E-03 For Julian Day 206, selecting COMIDA2 results # 6 of 9 38 206 7 11 8.42E-03 For Julian Day 206, selecting COMIDA2 results # 6 of 9 39 208 3 22 9.70E-03 For Julian Day 208, selecting COMIDA2 results # 6 of 9 40 212 5 20 2.08E-03 For Julian Day 212, selecting COMIDA2 results # 6 of 9 41 212 6 19 2.71E-03 For Julian Day 212, selecting COMIDA2 results # 6 of 9 42 212 13 17 8.28E-03 For Julian Day 212, selecting COMIDA2 results # 6 of 9 43 213 1 3 6.22E-03 For Julian Day 213, selecting COMIDA2 results # 6 of 9 44 216 17 39 6.28E-04 For Julian Day 216, selecting COMIDA2 results # 6 of 9 45 216 19 35 8.56E-04 For Julian Day 216, selecting COMIDA2 results # 6 of 9 46 218 15 5 4.85E-02 For Julian Day 218, selecting COMIDA2 results # 6 of 9 47 219 21 27 5.42E-04 For Julian Day 219, selecting COMIDA2 results # 6 of 9 48 219 22 26 2.00E-04 For Julian Day 219, selecting COMIDA2 results # 6 of 9 49 219 23 25 4.00E-04 For Julian Day 219, selecting COMIDA2 results # 6 of 9 50 228 16 40 1.14E-03 For Julian Day 228, selecting COMIDA2 results # 7 of 9 TRIAL DAY HOUR BIN PRBMET 51 228 22 39 6.28E-04 For Julian Day 228, selecting COMIDA2 results # 7 of 9 52 228 23 39 6.28E-04 For Julian Day 228, selecting COMIDA2 results # 7 of 9 53 229 1 38 1.71E-04 For Julian Day 229, selecting COMIDA2 results # 7 of 9 54 229 2 38 1.71E-04 For Julian Day 229, selecting COMIDA2 results # 7 of 9
Calculation IP-CALC-09-00265, Rev. 0, Att. A.2, Page 49 55 229 3 37 2.85E-04 For Julian Day 229, selecting COMIDA2 results # 7 of 9 56 245 12 24 1.43E-04 For Julian Day 245, selecting COMIDA2 results # 7 of 9 57 246 6 21 5.76E-03 For Julian Day 246, selecting COMIDA2 results # 7 of 9 58 250 2 11 8.42E-03 For Julian Day 250, selecting COMIDA2 results # 7 of 9 59 251 14 1 3.11E-03 For Julian Day 251, selecting COMIDA2 results # 7 of 9 60 256 23 33 4.00E-04 For Julian Day 256, selecting COMIDA2 results # 7 of 9 61 257 1 31 2.00E-04 For Julian Day 257, selecting COMIDA2 results # 8 of 9 62 258 17 40 1.14E-03 For Julian Day 258, selecting COMIDA2 results # 8 of 9 63 258 22 38 1.71E-04 For Julian Day 258, selecting COMIDA2 results # 8 of 9 64 258 23 37 2.85E-04 For Julian Day 258, selecting COMIDA2 results # 8 of 9 65 258 24 36 1.14E-04 For Julian Day 258, selecting COMIDA2 results # 8 of 9 66 259 2 29 5.99E-04 For Julian Day 259, selecting COMIDA2 results # 8 of 9 67 260 24 10 2.56E-02 For Julian Day 260, selecting COMIDA2 results # 8 of 9 68 263 9 40 1.14E-03 For Julian Day 263, selecting COMIDA2 results # 8 of 9 69 263 13 39 6.28E-04 For Julian Day 263, selecting COMIDA2 results # 8 of 9 70 263 18 35 8.56E-04 For Julian Day 263, selecting COMIDA2 results # 8 of 9 71 264 23 13 5.08E-03 For Julian Day 264, selecting COMIDA2 results # 8 of 9 72 271 19 9 1.55E-02 For Julian Day 271, selecting COMIDA2 results # 8 of 9 73 272 11 2 2.60E-03 For Julian Day 272, selecting COMIDA2 results # 8 of 9 74 273 15 4 3.93E-02 For Julian Day 273, selecting COMIDA2 results # 8 of 9 75 276 24 14 6.85E-03 For Julian Day 276, selecting COMIDA2 results # 8 of 9 76 282 12 1 3.11E-03 For Julian Day 282, selecting COMIDA2 results # 8 of 9 77 284 13 5 4.85E-02 For Julian Day 284, selecting COMIDA2 results # 8 of 9 78 288 6 13 5.08E-03 For Julian Day 288, selecting COMIDA2 results # 9 of 9 79 295 23 12 1.63E-03 For Julian Day 295, selecting COMIDA2 results # 9 of 9 80 299 2 15 1.66E-03 For Julian Day 299, selecting COMIDA2 results # 9 of 9 81 301 3 14 6.85E-03 For Julian Day 301, selecting COMIDA2 results # 9 of 9 82 302 10 7 4.17E-03 For Julian Day 302, selecting COMIDA2 results # 9 of 9 83 311 8 4 3.93E-02 For Julian Day 311, selecting COMIDA2 results # 9 of 9 84 314 10 22 9.70E-03
Calculation IP-CALC-09-00265, Rev. 0, Att. A.2, Page 50 For Julian Day 314, selecting COMIDA2 results # 9 of 9 85 314 18 20 2.08E-03 For Julian Day 314, selecting COMIDA2 results # 9 of 9 86 314 20 18 1.34E-03 For Julian Day 314, selecting COMIDA2 results # 9 of 9 87 315 9 23 1.86E-03 For Julian Day 315, selecting COMIDA2 results # 9 of 9 88 319 8 19 2.71E-03 For Julian Day 319, selecting COMIDA2 results # 9 of 9 89 319 16 25 4.00E-04 For Julian Day 319, selecting COMIDA2 results # 9 of 9 90 331 16 11 8.42E-03 For Julian Day 331, selecting COMIDA2 results # 9 of 9 91 334 22 19 2.71E-03 For Julian Day 334, selecting COMIDA2 results # 1 of 9 92 339 18 10 2.56E-02 For Julian Day 339, selecting COMIDA2 results # 1 of 9 93 347 10 8 1.43E-04 For Julian Day 347, selecting COMIDA2 results # 1 of 9 94 349 6 23 1.86E-03 For Julian Day 349, selecting COMIDA2 results # 1 of 9 95 352 8 27 5.42E-04 For Julian Day 352, selecting COMIDA2 results # 1 of 9 96 363 1 5 4.85E-02 For Julian Day 363, selecting COMIDA2 results # 1 of 9 97 364 6 6 4.15E-02 For Julian Day 364, selecting COMIDA2 results # 1 of 9 98 365 11 17 8.28E-03 For Julian Day 365, selecting COMIDA2 results # 1 of 9 99 4 13 34 8.28E-04 For Julian Day 4, selecting COMIDA2 results # 1 of 9 100 9 8 22 9.70E-03 For Julian Day 9, selecting COMIDA2 results # 1 of 9 TRIAL DAY HOUR BIN PRBMET 101 10 3 34 8.28E-04 For Julian Day 10, selecting COMIDA2 results # 1 of 9 102 10 8 33 4.00E-04 For Julian Day 10, selecting COMIDA2 results # 1 of 9 103 10 11 32 1.14E-04 For Julian Day 10, selecting COMIDA2 results # 1 of 9 104 10 13 31 2.00E-04 For Julian Day 10, selecting COMIDA2 results # 1 of 9 105 11 1 12 1.63E-03 For Julian Day 11, selecting COMIDA2 results # 1 of 9 106 13 16 7 4.17E-03 For Julian Day 13, selecting COMIDA2 results # 1 of 9 107 14 15 7 4.17E-03 For Julian Day 14, selecting COMIDA2 results # 1 of 9 108 16 23 8 1.43E-04 For Julian Day 16, selecting COMIDA2 results # 1 of 9 109 22 12 6 4.15E-02 For Julian Day 22, selecting COMIDA2 results # 1 of 9 110 25 11 8 1.43E-04 For Julian Day 25, selecting COMIDA2 results # 1 of 9 111 30 20 18 1.34E-03 For Julian Day 30, selecting COMIDA2 results # 1 of 9 112 38 2 12 1.63E-03
Calculation IP-CALC-09-00265, Rev. 0, Att. A.2, Page 51 For Julian Day 38, selecting COMIDA2 results # 2 of 9 113 40 2 11 8.42E-03 For Julian Day 40, selecting COMIDA2 results # 2 of 9 114 41 2 15 1.66E-03 For Julian Day 41, selecting COMIDA2 results # 2 of 9 115 44 5 16 2.00E-04 For Julian Day 44, selecting COMIDA2 results # 2 of 9 116 45 11 16 2.00E-04 For Julian Day 45, selecting COMIDA2 results # 2 of 9 117 49 8 21 5.76E-03 For Julian Day 49, selecting COMIDA2 results # 2 of 9 118 49 9 20 2.08E-03 For Julian Day 49, selecting COMIDA2 results # 2 of 9 119 49 17 17 8.28E-03 For Julian Day 49, selecting COMIDA2 results # 2 of 9 120 55 4 13 5.08E-03 For Julian Day 55, selecting COMIDA2 results # 2 of 9 121 56 2 28 1.23E-03 For Julian Day 56, selecting COMIDA2 results # 2 of 9 122 56 9 26 2.00E-04 For Julian Day 56, selecting COMIDA2 results # 2 of 9 123 58 2 9 1.55E-02 For Julian Day 58, selecting COMIDA2 results # 2 of 9 124 58 24 31 2.00E-04 For Julian Day 58, selecting COMIDA2 results # 2 of 9 125 59 1 30 1.14E-04 For Julian Day 59, selecting COMIDA2 results # 2 of 9 126 71 15 29 5.99E-04 For Julian Day 71, selecting COMIDA2 results # 2 of 9 127 78 4 8 1.43E-04 For Julian Day 78, selecting COMIDA2 results # 2 of 9 128 78 9 6 4.15E-02 For Julian Day 78, selecting COMIDA2 results # 2 of 9 129 86 3 13 5.08E-03 For Julian Day 86, selecting COMIDA2 results # 2 of 9 130 88 2 29 5.99E-04 For Julian Day 88, selecting COMIDA2 results # 2 of 9 131 95 6 19 2.71E-03 For Julian Day 95, selecting COMIDA2 results # 3 of 9 132 95 7 17 8.28E-03 For Julian Day 95, selecting COMIDA2 results # 3 of 9 133 95 10 12 1.63E-03 For Julian Day 95, selecting COMIDA2 results # 3 of 9 134 97 2 9 1.55E-02 For Julian Day 97, selecting COMIDA2 results # 3 of 9 135 97 3 10 2.56E-02 For Julian Day 97, selecting COMIDA2 results # 3 of 9 136 97 20 7 4.17E-03 For Julian Day 97, selecting COMIDA2 results # 3 of 9 137 99 5 3 6.22E-03 For Julian Day 99, selecting COMIDA2 results # 3 of 9 138 100 1 21 5.76E-03 For Julian Day 100, selecting COMIDA2 results # 3 of 9 139 105 16 2 2.60E-03 For Julian Day 105, selecting COMIDA2 results # 3 of 9 140 112 17 23 1.86E-03 For Julian Day 112, selecting COMIDA2 results # 3 of 9 141 120 6 16 2.00E-04 For Julian Day 120, selecting COMIDA2 results # 3 of 9
Calculation IP-CALC-09-00265, Rev. 0, Att. A.2, Page 52 142 124 3 14 6.85E-03 For Julian Day 124, selecting COMIDA2 results # 3 of 9 143 125 13 2 2.60E-03 For Julian Day 125, selecting COMIDA2 results # 3 of 9 144 127 11 4 3.93E-02 For Julian Day 127, selecting COMIDA2 results # 3 of 9 145 129 7 34 8.28E-04 For Julian Day 129, selecting COMIDA2 results # 3 of 9 146 129 12 33 4.00E-04 For Julian Day 129, selecting COMIDA2 results # 3 of 9 147 129 13 32 1.14E-04 For Julian Day 129, selecting COMIDA2 results # 3 of 9 148 131 17 20 2.08E-03 For Julian Day 131, selecting COMIDA2 results # 3 of 9 149 132 15 5 4.85E-02 For Julian Day 132, selecting COMIDA2 results # 3 of 9 150 134 21 35 8.56E-04 For Julian Day 134, selecting COMIDA2 results # 3 of 9 TRIAL DAY HOUR BIN PRBMET 151 137 14 1 3.11E-03 For Julian Day 137, selecting COMIDA2 results # 4 of 9 152 138 23 22 9.70E-03 For Julian Day 138, selecting COMIDA2 results # 4 of 9 153 141 9 18 1.34E-03 For Julian Day 141, selecting COMIDA2 results # 4 of 9 154 145 1 37 2.85E-04 For Julian Day 145, selecting COMIDA2 results # 4 of 9 155 151 1 3 6.22E-03 For Julian Day 151, selecting COMIDA2 results # 4 of 9
Calculation IP-CALC-09-00265, Rev. 0, Att. A.2, Page 53 WARNING!! WARNING!! WARNING!! WARNING!!
THE TOTAL RELEASE DURATION EXCEEDS 20 HOURS.
THIS MAY CAUSE ERRONEOUS RESULTS TO BE PRODUCED.
WARNING!! WARNING!! WARNING!! WARNING!!
Calculation IP-CALC-09-00265, Rev. 0, Att. A.2, Page 54 WARNING!! WARNING!! WARNING!! WARNING!!
A 10 HOUR RELEASE DURATION IS BEING USED BY ATMOS FOR CALCULATING THE EXPANSION FACTOR OF PLUME # 1 INSTEAD OF THE USER-SUPPLIED 22.00 HOURS WARNING!! WARNING!! WARNING!! WARNING!!
For Julian Day 152, selecting COMIDA2 results # 4 of 9 For Julian Day 156, selecting COMIDA2 results # 4 of 9 For Julian Day 156, selecting COMIDA2 results # 4 of 9 For Julian Day 158, selecting COMIDA2 results # 4 of 9 For Julian Day 158, selecting COMIDA2 results # 4 of 9 For Julian Day 163, selecting COMIDA2 results # 4 of 9 For Julian Day 163, selecting COMIDA2 results # 4 of 9 For Julian Day 163, selecting COMIDA2 results # 4 of 9 For Julian Day 163, selecting COMIDA2 results # 4 of 9 For Julian Day 164, selecting COMIDA2 results # 4 of 9 For Julian Day 165, selecting COMIDA2 results # 4 of 9 For Julian Day 165, selecting COMIDA2 results # 4 of 9 For Julian Day 165, selecting COMIDA2 results # 4 of 9 For Julian Day 166, selecting COMIDA2 results # 4 of 9 For Julian Day 166, selecting COMIDA2 results # 4 of 9 For Julian Day 169, selecting COMIDA2 results # 5 of 9 For Julian Day 170, selecting COMIDA2 results # 5 of 9 For Julian Day 179, selecting COMIDA2 results # 5 of 9 For Julian Day 179, selecting COMIDA2 results # 5 of 9 For Julian Day 179, selecting COMIDA2 results # 5 of 9 For Julian Day 179, selecting COMIDA2 results # 5 of 9 For Julian Day 180, selecting COMIDA2 results # 5 of 9 For Julian Day 180, selecting COMIDA2 results # 5 of 9 For Julian Day 184, selecting COMIDA2 results # 5 of 9 For Julian Day 193, selecting COMIDA2 results # 6 of 9 For Julian Day 196, selecting COMIDA2 results # 6 of 9 For Julian Day 196, selecting COMIDA2 results # 6 of 9 For Julian Day 197, selecting COMIDA2 results # 6 of 9 For Julian Day 197, selecting COMIDA2 results # 6 of 9 For Julian Day 197, selecting COMIDA2 results # 6 of 9 For Julian Day 197, selecting COMIDA2 results # 6 of 9 For Julian Day 199, selecting COMIDA2 results # 6 of 9 For Julian Day 200, selecting COMIDA2 results # 6 of 9 For Julian Day 200, selecting COMIDA2 results # 6 of 9 For Julian Day 200, selecting COMIDA2 results # 6 of 9 For Julian Day 203, selecting COMIDA2 results # 6 of 9 For Julian Day 206, selecting COMIDA2 results # 6 of 9 For Julian Day 206, selecting COMIDA2 results # 6 of 9 For Julian Day 208, selecting COMIDA2 results # 6 of 9 For Julian Day 212, selecting COMIDA2 results # 6 of 9 For Julian Day 212, selecting COMIDA2 results # 6 of 9 For Julian Day 212, selecting COMIDA2 results # 6 of 9 For Julian Day 213, selecting COMIDA2 results # 6 of 9 For Julian Day 216, selecting COMIDA2 results # 6 of 9 For Julian Day 216, selecting COMIDA2 results # 6 of 9 For Julian Day 218, selecting COMIDA2 results # 6 of 9 For Julian Day 219, selecting COMIDA2 results # 6 of 9 For Julian Day 219, selecting COMIDA2 results # 6 of 9 For Julian Day 219, selecting COMIDA2 results # 6 of 9 For Julian Day 228, selecting COMIDA2 results # 7 of 9 For Julian Day 228, selecting COMIDA2 results # 7 of 9
Calculation IP-CALC-09-00265, Rev. 0, Att. A.2, Page 55 For Julian Day 228, selecting COMIDA2 results # 7 of 9 For Julian Day 229, selecting COMIDA2 results # 7 of 9 For Julian Day 229, selecting COMIDA2 results # 7 of 9 For Julian Day 229, selecting COMIDA2 results # 7 of 9 For Julian Day 245, selecting COMIDA2 results # 7 of 9 For Julian Day 246, selecting COMIDA2 results # 7 of 9 For Julian Day 250, selecting COMIDA2 results # 7 of 9 For Julian Day 251, selecting COMIDA2 results # 7 of 9 For Julian Day 256, selecting COMIDA2 results # 7 of 9 For Julian Day 257, selecting COMIDA2 results # 8 of 9 For Julian Day 258, selecting COMIDA2 results # 8 of 9 For Julian Day 258, selecting COMIDA2 results # 8 of 9 For Julian Day 258, selecting COMIDA2 results # 8 of 9 For Julian Day 258, selecting COMIDA2 results # 8 of 9 For Julian Day 259, selecting COMIDA2 results # 8 of 9 For Julian Day 260, selecting COMIDA2 results # 8 of 9 For Julian Day 263, selecting COMIDA2 results # 8 of 9 For Julian Day 263, selecting COMIDA2 results # 8 of 9 For Julian Day 263, selecting COMIDA2 results # 8 of 9 For Julian Day 264, selecting COMIDA2 results # 8 of 9 For Julian Day 271, selecting COMIDA2 results # 8 of 9 For Julian Day 272, selecting COMIDA2 results # 8 of 9 For Julian Day 273, selecting COMIDA2 results # 8 of 9 For Julian Day 276, selecting COMIDA2 results # 8 of 9 For Julian Day 282, selecting COMIDA2 results # 8 of 9 For Julian Day 284, selecting COMIDA2 results # 8 of 9 For Julian Day 288, selecting COMIDA2 results # 9 of 9 For Julian Day 295, selecting COMIDA2 results # 9 of 9 For Julian Day 299, selecting COMIDA2 results # 9 of 9 For Julian Day 301, selecting COMIDA2 results # 9 of 9 For Julian Day 302, selecting COMIDA2 results # 9 of 9 For Julian Day 311, selecting COMIDA2 results # 9 of 9 For Julian Day 314, selecting COMIDA2 results # 9 of 9 For Julian Day 314, selecting COMIDA2 results # 9 of 9 For Julian Day 314, selecting COMIDA2 results # 9 of 9 For Julian Day 315, selecting COMIDA2 results # 9 of 9 For Julian Day 319, selecting COMIDA2 results # 9 of 9 For Julian Day 319, selecting COMIDA2 results # 9 of 9 For Julian Day 331, selecting COMIDA2 results # 9 of 9 For Julian Day 334, selecting COMIDA2 results # 1 of 9 For Julian Day 339, selecting COMIDA2 results # 1 of 9 For Julian Day 347, selecting COMIDA2 results # 1 of 9 For Julian Day 349, selecting COMIDA2 results # 1 of 9 For Julian Day 352, selecting COMIDA2 results # 1 of 9 For Julian Day 363, selecting COMIDA2 results # 1 of 9 For Julian Day 364, selecting COMIDA2 results # 1 of 9 For Julian Day 365, selecting COMIDA2 results # 1 of 9 For Julian Day 4, selecting COMIDA2 results # 1 of 9 For Julian Day 9, selecting COMIDA2 results # 1 of 9 For Julian Day 10, selecting COMIDA2 results # 1 of 9 For Julian Day 10, selecting COMIDA2 results # 1 of 9 For Julian Day 10, selecting COMIDA2 results # 1 of 9 For Julian Day 10, selecting COMIDA2 results # 1 of 9 For Julian Day 11, selecting COMIDA2 results # 1 of 9 For Julian Day 13, selecting COMIDA2 results # 1 of 9 For Julian Day 14, selecting COMIDA2 results # 1 of 9 For Julian Day 16, selecting COMIDA2 results # 1 of 9 For Julian Day 22, selecting COMIDA2 results # 1 of 9 For Julian Day 25, selecting COMIDA2 results # 1 of 9
Calculation IP-CALC-09-00265, Rev. 0, Att. A.2, Page 56 For Julian Day 30, selecting COMIDA2 results # 1 of 9 For Julian Day 38, selecting COMIDA2 results # 2 of 9 For Julian Day 40, selecting COMIDA2 results # 2 of 9 For Julian Day 41, selecting COMIDA2 results # 2 of 9 For Julian Day 44, selecting COMIDA2 results # 2 of 9 For Julian Day 45, selecting COMIDA2 results # 2 of 9 For Julian Day 49, selecting COMIDA2 results # 2 of 9 For Julian Day 49, selecting COMIDA2 results # 2 of 9 For Julian Day 49, selecting COMIDA2 results # 2 of 9 For Julian Day 55, selecting COMIDA2 results # 2 of 9 For Julian Day 56, selecting COMIDA2 results # 2 of 9 For Julian Day 56, selecting COMIDA2 results # 2 of 9 For Julian Day 58, selecting COMIDA2 results # 2 of 9 For Julian Day 58, selecting COMIDA2 results # 2 of 9 For Julian Day 59, selecting COMIDA2 results # 2 of 9 For Julian Day 71, selecting COMIDA2 results # 2 of 9 For Julian Day 78, selecting COMIDA2 results # 2 of 9 For Julian Day 78, selecting COMIDA2 results # 2 of 9 For Julian Day 86, selecting COMIDA2 results # 2 of 9 For Julian Day 88, selecting COMIDA2 results # 2 of 9 For Julian Day 95, selecting COMIDA2 results # 3 of 9 For Julian Day 95, selecting COMIDA2 results # 3 of 9 For Julian Day 95, selecting COMIDA2 results # 3 of 9 For Julian Day 97, selecting COMIDA2 results # 3 of 9 For Julian Day 97, selecting COMIDA2 results # 3 of 9 For Julian Day 97, selecting COMIDA2 results # 3 of 9 For Julian Day 99, selecting COMIDA2 results # 3 of 9 For Julian Day 100, selecting COMIDA2 results # 3 of 9 For Julian Day 105, selecting COMIDA2 results # 3 of 9 For Julian Day 112, selecting COMIDA2 results # 3 of 9 For Julian Day 120, selecting COMIDA2 results # 3 of 9 For Julian Day 124, selecting COMIDA2 results # 3 of 9 For Julian Day 125, selecting COMIDA2 results # 3 of 9 For Julian Day 127, selecting COMIDA2 results # 3 of 9 For Julian Day 129, selecting COMIDA2 results # 3 of 9 For Julian Day 129, selecting COMIDA2 results # 3 of 9 For Julian Day 129, selecting COMIDA2 results # 3 of 9 For Julian Day 131, selecting COMIDA2 results # 3 of 9 For Julian Day 132, selecting COMIDA2 results # 3 of 9 For Julian Day 134, selecting COMIDA2 results # 3 of 9 For Julian Day 137, selecting COMIDA2 results # 4 of 9 For Julian Day 138, selecting COMIDA2 results # 4 of 9 For Julian Day 141, selecting COMIDA2 results # 4 of 9 For Julian Day 145, selecting COMIDA2 results # 4 of 9 For Julian Day 151, selecting COMIDA2 results # 4 of 9
Calculation IP-CALC-09-00265, Rev. 0, Att. A.2, Page 57 WARNING!! WARNING!! WARNING!! WARNING!!
THE TOTAL RELEASE DURATION EXCEEDS 20 HOURS.
THIS MAY CAUSE ERRONEOUS RESULTS TO BE PRODUCED.
WARNING!! WARNING!! WARNING!! WARNING!!
Calculation IP-CALC-09-00265, Rev. 0, Att. A.2, Page 58 WARNING!! WARNING!! WARNING!! WARNING!!
A 10 HOUR RELEASE DURATION IS BEING USED BY ATMOS FOR CALCULATING THE EXPANSION FACTOR OF PLUME # 1 INSTEAD OF THE USER-SUPPLIED 22.81 HOURS WARNING!! WARNING!! WARNING!! WARNING!!
For Julian Day 152, selecting COMIDA2 results # 4 of 9 For Julian Day 156, selecting COMIDA2 results # 4 of 9 For Julian Day 156, selecting COMIDA2 results # 4 of 9 For Julian Day 158, selecting COMIDA2 results # 4 of 9 For Julian Day 158, selecting COMIDA2 results # 4 of 9 For Julian Day 163, selecting COMIDA2 results # 4 of 9 For Julian Day 163, selecting COMIDA2 results # 4 of 9 For Julian Day 163, selecting COMIDA2 results # 4 of 9 For Julian Day 163, selecting COMIDA2 results # 4 of 9 For Julian Day 164, selecting COMIDA2 results # 4 of 9 For Julian Day 165, selecting COMIDA2 results # 4 of 9 For Julian Day 165, selecting COMIDA2 results # 4 of 9 For Julian Day 165, selecting COMIDA2 results # 4 of 9 For Julian Day 166, selecting COMIDA2 results # 4 of 9 For Julian Day 166, selecting COMIDA2 results # 4 of 9 For Julian Day 169, selecting COMIDA2 results # 5 of 9 For Julian Day 170, selecting COMIDA2 results # 5 of 9 For Julian Day 179, selecting COMIDA2 results # 5 of 9 For Julian Day 179, selecting COMIDA2 results # 5 of 9 For Julian Day 179, selecting COMIDA2 results # 5 of 9 For Julian Day 179, selecting COMIDA2 results # 5 of 9 For Julian Day 180, selecting COMIDA2 results # 5 of 9 For Julian Day 180, selecting COMIDA2 results # 5 of 9 For Julian Day 184, selecting COMIDA2 results # 5 of 9 For Julian Day 193, selecting COMIDA2 results # 6 of 9 For Julian Day 196, selecting COMIDA2 results # 6 of 9 For Julian Day 196, selecting COMIDA2 results # 6 of 9 For Julian Day 197, selecting COMIDA2 results # 6 of 9 For Julian Day 197, selecting COMIDA2 results # 6 of 9 For Julian Day 197, selecting COMIDA2 results # 6 of 9 For Julian Day 197, selecting COMIDA2 results # 6 of 9 For Julian Day 199, selecting COMIDA2 results # 6 of 9 For Julian Day 200, selecting COMIDA2 results # 6 of 9 For Julian Day 200, selecting COMIDA2 results # 6 of 9 For Julian Day 200, selecting COMIDA2 results # 6 of 9 For Julian Day 203, selecting COMIDA2 results # 6 of 9 For Julian Day 206, selecting COMIDA2 results # 6 of 9 For Julian Day 206, selecting COMIDA2 results # 6 of 9 For Julian Day 208, selecting COMIDA2 results # 6 of 9 For Julian Day 212, selecting COMIDA2 results # 6 of 9 For Julian Day 212, selecting COMIDA2 results # 6 of 9 For Julian Day 212, selecting COMIDA2 results # 6 of 9 For Julian Day 213, selecting COMIDA2 results # 6 of 9 For Julian Day 216, selecting COMIDA2 results # 6 of 9 For Julian Day 216, selecting COMIDA2 results # 6 of 9 For Julian Day 218, selecting COMIDA2 results # 6 of 9 For Julian Day 219, selecting COMIDA2 results # 6 of 9 For Julian Day 219, selecting COMIDA2 results # 6 of 9 For Julian Day 219, selecting COMIDA2 results # 6 of 9 For Julian Day 228, selecting COMIDA2 results # 7 of 9 For Julian Day 228, selecting COMIDA2 results # 7 of 9
Calculation IP-CALC-09-00265, Rev. 0, Att. A.2, Page 59 For Julian Day 228, selecting COMIDA2 results # 7 of 9 For Julian Day 229, selecting COMIDA2 results # 7 of 9 For Julian Day 229, selecting COMIDA2 results # 7 of 9 For Julian Day 229, selecting COMIDA2 results # 7 of 9 For Julian Day 245, selecting COMIDA2 results # 7 of 9 For Julian Day 246, selecting COMIDA2 results # 7 of 9 For Julian Day 250, selecting COMIDA2 results # 7 of 9 For Julian Day 251, selecting COMIDA2 results # 7 of 9 For Julian Day 256, selecting COMIDA2 results # 7 of 9 For Julian Day 257, selecting COMIDA2 results # 8 of 9 For Julian Day 258, selecting COMIDA2 results # 8 of 9 For Julian Day 258, selecting COMIDA2 results # 8 of 9 For Julian Day 258, selecting COMIDA2 results # 8 of 9 For Julian Day 258, selecting COMIDA2 results # 8 of 9 For Julian Day 259, selecting COMIDA2 results # 8 of 9 For Julian Day 260, selecting COMIDA2 results # 8 of 9 For Julian Day 263, selecting COMIDA2 results # 8 of 9 For Julian Day 263, selecting COMIDA2 results # 8 of 9 For Julian Day 263, selecting COMIDA2 results # 8 of 9 For Julian Day 264, selecting COMIDA2 results # 8 of 9 For Julian Day 271, selecting COMIDA2 results # 8 of 9 For Julian Day 272, selecting COMIDA2 results # 8 of 9 For Julian Day 273, selecting COMIDA2 results # 8 of 9 For Julian Day 276, selecting COMIDA2 results # 8 of 9 For Julian Day 282, selecting COMIDA2 results # 8 of 9 For Julian Day 284, selecting COMIDA2 results # 8 of 9 For Julian Day 288, selecting COMIDA2 results # 9 of 9 For Julian Day 295, selecting COMIDA2 results # 9 of 9 For Julian Day 299, selecting COMIDA2 results # 9 of 9 For Julian Day 301, selecting COMIDA2 results # 9 of 9 For Julian Day 302, selecting COMIDA2 results # 9 of 9 For Julian Day 311, selecting COMIDA2 results # 9 of 9 For Julian Day 314, selecting COMIDA2 results # 9 of 9 For Julian Day 314, selecting COMIDA2 results # 9 of 9 For Julian Day 314, selecting COMIDA2 results # 9 of 9 For Julian Day 315, selecting COMIDA2 results # 9 of 9 For Julian Day 319, selecting COMIDA2 results # 9 of 9 For Julian Day 319, selecting COMIDA2 results # 9 of 9 For Julian Day 331, selecting COMIDA2 results # 9 of 9 For Julian Day 334, selecting COMIDA2 results # 1 of 9 For Julian Day 339, selecting COMIDA2 results # 1 of 9 For Julian Day 347, selecting COMIDA2 results # 1 of 9 For Julian Day 349, selecting COMIDA2 results # 1 of 9 For Julian Day 352, selecting COMIDA2 results # 1 of 9 For Julian Day 363, selecting COMIDA2 results # 1 of 9 For Julian Day 364, selecting COMIDA2 results # 1 of 9 For Julian Day 365, selecting COMIDA2 results # 1 of 9 For Julian Day 4, selecting COMIDA2 results # 1 of 9 For Julian Day 9, selecting COMIDA2 results # 1 of 9 For Julian Day 10, selecting COMIDA2 results # 1 of 9 For Julian Day 10, selecting COMIDA2 results # 1 of 9 For Julian Day 10, selecting COMIDA2 results # 1 of 9 For Julian Day 10, selecting COMIDA2 results # 1 of 9 For Julian Day 11, selecting COMIDA2 results # 1 of 9 For Julian Day 13, selecting COMIDA2 results # 1 of 9 For Julian Day 14, selecting COMIDA2 results # 1 of 9 For Julian Day 16, selecting COMIDA2 results # 1 of 9 For Julian Day 22, selecting COMIDA2 results # 1 of 9 For Julian Day 25, selecting COMIDA2 results # 1 of 9
Calculation IP-CALC-09-00265, Rev. 0, Att. A.2, Page 60 For Julian Day 30, selecting COMIDA2 results # 1 of 9 For Julian Day 38, selecting COMIDA2 results # 2 of 9 For Julian Day 40, selecting COMIDA2 results # 2 of 9 For Julian Day 41, selecting COMIDA2 results # 2 of 9 For Julian Day 44, selecting COMIDA2 results # 2 of 9 For Julian Day 45, selecting COMIDA2 results # 2 of 9 For Julian Day 49, selecting COMIDA2 results # 2 of 9 For Julian Day 49, selecting COMIDA2 results # 2 of 9 For Julian Day 49, selecting COMIDA2 results # 2 of 9 For Julian Day 55, selecting COMIDA2 results # 2 of 9 For Julian Day 56, selecting COMIDA2 results # 2 of 9 For Julian Day 56, selecting COMIDA2 results # 2 of 9 For Julian Day 58, selecting COMIDA2 results # 2 of 9 For Julian Day 58, selecting COMIDA2 results # 2 of 9 For Julian Day 59, selecting COMIDA2 results # 2 of 9 For Julian Day 71, selecting COMIDA2 results # 2 of 9 For Julian Day 78, selecting COMIDA2 results # 2 of 9 For Julian Day 78, selecting COMIDA2 results # 2 of 9 For Julian Day 86, selecting COMIDA2 results # 2 of 9 For Julian Day 88, selecting COMIDA2 results # 2 of 9 For Julian Day 95, selecting COMIDA2 results # 3 of 9 For Julian Day 95, selecting COMIDA2 results # 3 of 9 For Julian Day 95, selecting COMIDA2 results # 3 of 9 For Julian Day 97, selecting COMIDA2 results # 3 of 9 For Julian Day 97, selecting COMIDA2 results # 3 of 9 For Julian Day 97, selecting COMIDA2 results # 3 of 9 For Julian Day 99, selecting COMIDA2 results # 3 of 9 For Julian Day 100, selecting COMIDA2 results # 3 of 9 For Julian Day 105, selecting COMIDA2 results # 3 of 9 For Julian Day 112, selecting COMIDA2 results # 3 of 9 For Julian Day 120, selecting COMIDA2 results # 3 of 9 For Julian Day 124, selecting COMIDA2 results # 3 of 9 For Julian Day 125, selecting COMIDA2 results # 3 of 9 For Julian Day 127, selecting COMIDA2 results # 3 of 9 For Julian Day 129, selecting COMIDA2 results # 3 of 9 For Julian Day 129, selecting COMIDA2 results # 3 of 9 For Julian Day 129, selecting COMIDA2 results # 3 of 9 For Julian Day 131, selecting COMIDA2 results # 3 of 9 For Julian Day 132, selecting COMIDA2 results # 3 of 9 For Julian Day 134, selecting COMIDA2 results # 3 of 9 For Julian Day 137, selecting COMIDA2 results # 4 of 9 For Julian Day 138, selecting COMIDA2 results # 4 of 9 For Julian Day 141, selecting COMIDA2 results # 4 of 9 For Julian Day 145, selecting COMIDA2 results # 4 of 9 For Julian Day 151, selecting COMIDA2 results # 4 of 9
Calculation IP-CALC-09-00265, Rev. 0, Att. A.2, Page 61 WARNING!! WARNING!! WARNING!! WARNING!!
THE TOTAL RELEASE DURATION EXCEEDS 20 HOURS.
THIS MAY CAUSE ERRONEOUS RESULTS TO BE PRODUCED.
WARNING!! WARNING!! WARNING!! WARNING!!
Calculation IP-CALC-09-00265, Rev. 0, Att. A.2, Page 62 WARNING!! WARNING!! WARNING!! WARNING!!
A 10 HOUR RELEASE DURATION IS BEING USED BY ATMOS FOR CALCULATING THE EXPANSION FACTOR OF PLUME # 1 INSTEAD OF THE USER-SUPPLIED 23.58 HOURS WARNING!! WARNING!! WARNING!! WARNING!!
For Julian Day 152, selecting COMIDA2 results # 4 of 9 For Julian Day 156, selecting COMIDA2 results # 4 of 9 For Julian Day 156, selecting COMIDA2 results # 4 of 9 For Julian Day 158, selecting COMIDA2 results # 4 of 9 For Julian Day 158, selecting COMIDA2 results # 4 of 9 For Julian Day 163, selecting COMIDA2 results # 4 of 9 For Julian Day 163, selecting COMIDA2 results # 4 of 9 For Julian Day 163, selecting COMIDA2 results # 4 of 9 For Julian Day 163, selecting COMIDA2 results # 4 of 9 For Julian Day 164, selecting COMIDA2 results # 4 of 9 For Julian Day 165, selecting COMIDA2 results # 4 of 9 For Julian Day 165, selecting COMIDA2 results # 4 of 9 For Julian Day 165, selecting COMIDA2 results # 4 of 9 For Julian Day 166, selecting COMIDA2 results # 4 of 9 For Julian Day 166, selecting COMIDA2 results # 4 of 9 For Julian Day 169, selecting COMIDA2 results # 5 of 9 For Julian Day 170, selecting COMIDA2 results # 5 of 9 For Julian Day 179, selecting COMIDA2 results # 5 of 9 For Julian Day 179, selecting COMIDA2 results # 5 of 9 For Julian Day 179, selecting COMIDA2 results # 5 of 9 For Julian Day 179, selecting COMIDA2 results # 5 of 9 For Julian Day 180, selecting COMIDA2 results # 5 of 9 For Julian Day 180, selecting COMIDA2 results # 5 of 9 For Julian Day 184, selecting COMIDA2 results # 5 of 9 For Julian Day 193, selecting COMIDA2 results # 6 of 9 For Julian Day 196, selecting COMIDA2 results # 6 of 9 For Julian Day 196, selecting COMIDA2 results # 6 of 9 For Julian Day 197, selecting COMIDA2 results # 6 of 9 For Julian Day 197, selecting COMIDA2 results # 6 of 9 For Julian Day 197, selecting COMIDA2 results # 6 of 9 For Julian Day 197, selecting COMIDA2 results # 6 of 9 For Julian Day 199, selecting COMIDA2 results # 6 of 9 For Julian Day 200, selecting COMIDA2 results # 6 of 9 For Julian Day 200, selecting COMIDA2 results # 6 of 9 For Julian Day 200, selecting COMIDA2 results # 6 of 9 For Julian Day 203, selecting COMIDA2 results # 6 of 9 For Julian Day 206, selecting COMIDA2 results # 6 of 9 For Julian Day 206, selecting COMIDA2 results # 6 of 9 For Julian Day 208, selecting COMIDA2 results # 6 of 9 For Julian Day 212, selecting COMIDA2 results # 6 of 9 For Julian Day 212, selecting COMIDA2 results # 6 of 9 For Julian Day 212, selecting COMIDA2 results # 6 of 9 For Julian Day 213, selecting COMIDA2 results # 6 of 9 For Julian Day 216, selecting COMIDA2 results # 6 of 9 For Julian Day 216, selecting COMIDA2 results # 6 of 9 For Julian Day 218, selecting COMIDA2 results # 6 of 9 For Julian Day 219, selecting COMIDA2 results # 6 of 9 For Julian Day 219, selecting COMIDA2 results # 6 of 9 For Julian Day 219, selecting COMIDA2 results # 6 of 9 For Julian Day 228, selecting COMIDA2 results # 7 of 9 For Julian Day 228, selecting COMIDA2 results # 7 of 9
Calculation IP-CALC-09-00265, Rev. 0, Att. A.2, Page 63 For Julian Day 228, selecting COMIDA2 results # 7 of 9 For Julian Day 229, selecting COMIDA2 results # 7 of 9 For Julian Day 229, selecting COMIDA2 results # 7 of 9 For Julian Day 229, selecting COMIDA2 results # 7 of 9 For Julian Day 245, selecting COMIDA2 results # 7 of 9 For Julian Day 246, selecting COMIDA2 results # 7 of 9 For Julian Day 250, selecting COMIDA2 results # 7 of 9 For Julian Day 251, selecting COMIDA2 results # 7 of 9 For Julian Day 256, selecting COMIDA2 results # 7 of 9 For Julian Day 257, selecting COMIDA2 results # 8 of 9 For Julian Day 258, selecting COMIDA2 results # 8 of 9 For Julian Day 258, selecting COMIDA2 results # 8 of 9 For Julian Day 258, selecting COMIDA2 results # 8 of 9 For Julian Day 258, selecting COMIDA2 results # 8 of 9 For Julian Day 259, selecting COMIDA2 results # 8 of 9 For Julian Day 260, selecting COMIDA2 results # 8 of 9 For Julian Day 263, selecting COMIDA2 results # 8 of 9 For Julian Day 263, selecting COMIDA2 results # 8 of 9 For Julian Day 263, selecting COMIDA2 results # 8 of 9 For Julian Day 264, selecting COMIDA2 results # 8 of 9 For Julian Day 271, selecting COMIDA2 results # 8 of 9 For Julian Day 272, selecting COMIDA2 results # 8 of 9 For Julian Day 273, selecting COMIDA2 results # 8 of 9 For Julian Day 276, selecting COMIDA2 results # 8 of 9 For Julian Day 282, selecting COMIDA2 results # 8 of 9 For Julian Day 284, selecting COMIDA2 results # 8 of 9 For Julian Day 288, selecting COMIDA2 results # 9 of 9 For Julian Day 295, selecting COMIDA2 results # 9 of 9 For Julian Day 299, selecting COMIDA2 results # 9 of 9 For Julian Day 301, selecting COMIDA2 results # 9 of 9 For Julian Day 302, selecting COMIDA2 results # 9 of 9 For Julian Day 311, selecting COMIDA2 results # 9 of 9 For Julian Day 314, selecting COMIDA2 results # 9 of 9 For Julian Day 314, selecting COMIDA2 results # 9 of 9 For Julian Day 314, selecting COMIDA2 results # 9 of 9 For Julian Day 315, selecting COMIDA2 results # 9 of 9 For Julian Day 319, selecting COMIDA2 results # 9 of 9 For Julian Day 319, selecting COMIDA2 results # 9 of 9 For Julian Day 331, selecting COMIDA2 results # 9 of 9 For Julian Day 334, selecting COMIDA2 results # 1 of 9 For Julian Day 339, selecting COMIDA2 results # 1 of 9 For Julian Day 347, selecting COMIDA2 results # 1 of 9 For Julian Day 349, selecting COMIDA2 results # 1 of 9 For Julian Day 352, selecting COMIDA2 results # 1 of 9 For Julian Day 363, selecting COMIDA2 results # 1 of 9 For Julian Day 364, selecting COMIDA2 results # 1 of 9 For Julian Day 365, selecting COMIDA2 results # 1 of 9 For Julian Day 4, selecting COMIDA2 results # 1 of 9 For Julian Day 9, selecting COMIDA2 results # 1 of 9 For Julian Day 10, selecting COMIDA2 results # 1 of 9 For Julian Day 10, selecting COMIDA2 results # 1 of 9 For Julian Day 10, selecting COMIDA2 results # 1 of 9 For Julian Day 10, selecting COMIDA2 results # 1 of 9 For Julian Day 11, selecting COMIDA2 results # 1 of 9 For Julian Day 13, selecting COMIDA2 results # 1 of 9 For Julian Day 14, selecting COMIDA2 results # 1 of 9 For Julian Day 16, selecting COMIDA2 results # 1 of 9 For Julian Day 22, selecting COMIDA2 results # 1 of 9 For Julian Day 25, selecting COMIDA2 results # 1 of 9
Calculation IP-CALC-09-00265, Rev. 0, Att. A.2, Page 64 For Julian Day 30, selecting COMIDA2 results # 1 of 9 For Julian Day 38, selecting COMIDA2 results # 2 of 9 For Julian Day 40, selecting COMIDA2 results # 2 of 9 For Julian Day 41, selecting COMIDA2 results # 2 of 9 For Julian Day 44, selecting COMIDA2 results # 2 of 9 For Julian Day 45, selecting COMIDA2 results # 2 of 9 For Julian Day 49, selecting COMIDA2 results # 2 of 9 For Julian Day 49, selecting COMIDA2 results # 2 of 9 For Julian Day 49, selecting COMIDA2 results # 2 of 9 For Julian Day 55, selecting COMIDA2 results # 2 of 9 For Julian Day 56, selecting COMIDA2 results # 2 of 9 For Julian Day 56, selecting COMIDA2 results # 2 of 9 For Julian Day 58, selecting COMIDA2 results # 2 of 9 For Julian Day 58, selecting COMIDA2 results # 2 of 9 For Julian Day 59, selecting COMIDA2 results # 2 of 9 For Julian Day 71, selecting COMIDA2 results # 2 of 9 For Julian Day 78, selecting COMIDA2 results # 2 of 9 For Julian Day 78, selecting COMIDA2 results # 2 of 9 For Julian Day 86, selecting COMIDA2 results # 2 of 9 For Julian Day 88, selecting COMIDA2 results # 2 of 9 For Julian Day 95, selecting COMIDA2 results # 3 of 9 For Julian Day 95, selecting COMIDA2 results # 3 of 9 For Julian Day 95, selecting COMIDA2 results # 3 of 9 For Julian Day 97, selecting COMIDA2 results # 3 of 9 For Julian Day 97, selecting COMIDA2 results # 3 of 9 For Julian Day 97, selecting COMIDA2 results # 3 of 9 For Julian Day 99, selecting COMIDA2 results # 3 of 9 For Julian Day 100, selecting COMIDA2 results # 3 of 9 For Julian Day 105, selecting COMIDA2 results # 3 of 9 For Julian Day 112, selecting COMIDA2 results # 3 of 9 For Julian Day 120, selecting COMIDA2 results # 3 of 9 For Julian Day 124, selecting COMIDA2 results # 3 of 9 For Julian Day 125, selecting COMIDA2 results # 3 of 9 For Julian Day 127, selecting COMIDA2 results # 3 of 9 For Julian Day 129, selecting COMIDA2 results # 3 of 9 For Julian Day 129, selecting COMIDA2 results # 3 of 9 For Julian Day 129, selecting COMIDA2 results # 3 of 9 For Julian Day 131, selecting COMIDA2 results # 3 of 9 For Julian Day 132, selecting COMIDA2 results # 3 of 9 For Julian Day 134, selecting COMIDA2 results # 3 of 9 For Julian Day 137, selecting COMIDA2 results # 4 of 9 For Julian Day 138, selecting COMIDA2 results # 4 of 9 For Julian Day 141, selecting COMIDA2 results # 4 of 9 For Julian Day 145, selecting COMIDA2 results # 4 of 9 For Julian Day 151, selecting COMIDA2 results # 4 of 9
Calculation IP-CALC-09-00265, Rev. 0, Att. A.2, Page 65 WARNING!! WARNING!! WARNING!! WARNING!!
THE TOTAL RELEASE DURATION EXCEEDS 20 HOURS.
THIS MAY CAUSE ERRONEOUS RESULTS TO BE PRODUCED.
WARNING!! WARNING!! WARNING!! WARNING!!
Calculation IP-CALC-09-00265, Rev. 0, Att. A.2, Page 66 WARNING!! WARNING!! WARNING!! WARNING!!
A 10 HOUR RELEASE DURATION IS BEING USED BY ATMOS FOR CALCULATING THE EXPANSION FACTOR OF PLUME # 1 INSTEAD OF THE USER-SUPPLIED 24.00 HOURS WARNING!! WARNING!! WARNING!! WARNING!!
For Julian Day 152, selecting COMIDA2 results # 4 of 9 For Julian Day 156, selecting COMIDA2 results # 4 of 9 For Julian Day 156, selecting COMIDA2 results # 4 of 9 For Julian Day 158, selecting COMIDA2 results # 4 of 9 For Julian Day 158, selecting COMIDA2 results # 4 of 9 For Julian Day 163, selecting COMIDA2 results # 4 of 9 For Julian Day 163, selecting COMIDA2 results # 4 of 9 For Julian Day 163, selecting COMIDA2 results # 4 of 9 For Julian Day 163, selecting COMIDA2 results # 4 of 9 For Julian Day 164, selecting COMIDA2 results # 4 of 9 For Julian Day 165, selecting COMIDA2 results # 4 of 9 For Julian Day 165, selecting COMIDA2 results # 4 of 9 For Julian Day 165, selecting COMIDA2 results # 4 of 9 For Julian Day 166, selecting COMIDA2 results # 4 of 9 For Julian Day 166, selecting COMIDA2 results # 4 of 9 For Julian Day 169, selecting COMIDA2 results # 5 of 9 For Julian Day 170, selecting COMIDA2 results # 5 of 9 For Julian Day 179, selecting COMIDA2 results # 5 of 9 For Julian Day 179, selecting COMIDA2 results # 5 of 9 For Julian Day 179, selecting COMIDA2 results # 5 of 9 For Julian Day 179, selecting COMIDA2 results # 5 of 9 For Julian Day 180, selecting COMIDA2 results # 5 of 9 For Julian Day 180, selecting COMIDA2 results # 5 of 9 For Julian Day 184, selecting COMIDA2 results # 5 of 9 For Julian Day 193, selecting COMIDA2 results # 6 of 9 For Julian Day 196, selecting COMIDA2 results # 6 of 9 For Julian Day 196, selecting COMIDA2 results # 6 of 9 For Julian Day 197, selecting COMIDA2 results # 6 of 9 For Julian Day 197, selecting COMIDA2 results # 6 of 9 For Julian Day 197, selecting COMIDA2 results # 6 of 9 For Julian Day 197, selecting COMIDA2 results # 6 of 9 For Julian Day 199, selecting COMIDA2 results # 6 of 9 For Julian Day 200, selecting COMIDA2 results # 6 of 9 For Julian Day 200, selecting COMIDA2 results # 6 of 9 For Julian Day 200, selecting COMIDA2 results # 6 of 9 For Julian Day 203, selecting COMIDA2 results # 6 of 9 For Julian Day 206, selecting COMIDA2 results # 6 of 9 For Julian Day 206, selecting COMIDA2 results # 6 of 9 For Julian Day 208, selecting COMIDA2 results # 6 of 9 For Julian Day 212, selecting COMIDA2 results # 6 of 9 For Julian Day 212, selecting COMIDA2 results # 6 of 9 For Julian Day 212, selecting COMIDA2 results # 6 of 9 For Julian Day 213, selecting COMIDA2 results # 6 of 9 For Julian Day 216, selecting COMIDA2 results # 6 of 9 For Julian Day 216, selecting COMIDA2 results # 6 of 9 For Julian Day 218, selecting COMIDA2 results # 6 of 9 For Julian Day 219, selecting COMIDA2 results # 6 of 9 For Julian Day 219, selecting COMIDA2 results # 6 of 9 For Julian Day 219, selecting COMIDA2 results # 6 of 9 For Julian Day 228, selecting COMIDA2 results # 7 of 9 For Julian Day 228, selecting COMIDA2 results # 7 of 9
Calculation IP-CALC-09-00265, Rev. 0, Att. A.2, Page 67 For Julian Day 228, selecting COMIDA2 results # 7 of 9 For Julian Day 229, selecting COMIDA2 results # 7 of 9 For Julian Day 229, selecting COMIDA2 results # 7 of 9 For Julian Day 229, selecting COMIDA2 results # 7 of 9 For Julian Day 245, selecting COMIDA2 results # 7 of 9 For Julian Day 246, selecting COMIDA2 results # 7 of 9 For Julian Day 250, selecting COMIDA2 results # 7 of 9 For Julian Day 251, selecting COMIDA2 results # 7 of 9 For Julian Day 256, selecting COMIDA2 results # 7 of 9 For Julian Day 257, selecting COMIDA2 results # 8 of 9 For Julian Day 258, selecting COMIDA2 results # 8 of 9 For Julian Day 258, selecting COMIDA2 results # 8 of 9 For Julian Day 258, selecting COMIDA2 results # 8 of 9 For Julian Day 258, selecting COMIDA2 results # 8 of 9 For Julian Day 259, selecting COMIDA2 results # 8 of 9 For Julian Day 260, selecting COMIDA2 results # 8 of 9 For Julian Day 263, selecting COMIDA2 results # 8 of 9 For Julian Day 263, selecting COMIDA2 results # 8 of 9 For Julian Day 263, selecting COMIDA2 results # 8 of 9 For Julian Day 264, selecting COMIDA2 results # 8 of 9 For Julian Day 271, selecting COMIDA2 results # 8 of 9 For Julian Day 272, selecting COMIDA2 results # 8 of 9 For Julian Day 273, selecting COMIDA2 results # 8 of 9 For Julian Day 276, selecting COMIDA2 results # 8 of 9 For Julian Day 282, selecting COMIDA2 results # 8 of 9 For Julian Day 284, selecting COMIDA2 results # 8 of 9 For Julian Day 288, selecting COMIDA2 results # 9 of 9 For Julian Day 295, selecting COMIDA2 results # 9 of 9 For Julian Day 299, selecting COMIDA2 results # 9 of 9 For Julian Day 301, selecting COMIDA2 results # 9 of 9 For Julian Day 302, selecting COMIDA2 results # 9 of 9 For Julian Day 311, selecting COMIDA2 results # 9 of 9 For Julian Day 314, selecting COMIDA2 results # 9 of 9 For Julian Day 314, selecting COMIDA2 results # 9 of 9 For Julian Day 314, selecting COMIDA2 results # 9 of 9 For Julian Day 315, selecting COMIDA2 results # 9 of 9 For Julian Day 319, selecting COMIDA2 results # 9 of 9 For Julian Day 319, selecting COMIDA2 results # 9 of 9 For Julian Day 331, selecting COMIDA2 results # 9 of 9 For Julian Day 334, selecting COMIDA2 results # 1 of 9 For Julian Day 339, selecting COMIDA2 results # 1 of 9 For Julian Day 347, selecting COMIDA2 results # 1 of 9 For Julian Day 349, selecting COMIDA2 results # 1 of 9 For Julian Day 352, selecting COMIDA2 results # 1 of 9 For Julian Day 363, selecting COMIDA2 results # 1 of 9 For Julian Day 364, selecting COMIDA2 results # 1 of 9 For Julian Day 365, selecting COMIDA2 results # 1 of 9 For Julian Day 4, selecting COMIDA2 results # 1 of 9 For Julian Day 9, selecting COMIDA2 results # 1 of 9 For Julian Day 10, selecting COMIDA2 results # 1 of 9 For Julian Day 10, selecting COMIDA2 results # 1 of 9 For Julian Day 10, selecting COMIDA2 results # 1 of 9 For Julian Day 10, selecting COMIDA2 results # 1 of 9 For Julian Day 11, selecting COMIDA2 results # 1 of 9 For Julian Day 13, selecting COMIDA2 results # 1 of 9 For Julian Day 14, selecting COMIDA2 results # 1 of 9 For Julian Day 16, selecting COMIDA2 results # 1 of 9 For Julian Day 22, selecting COMIDA2 results # 1 of 9 For Julian Day 25, selecting COMIDA2 results # 1 of 9
Calculation IP-CALC-09-00265, Rev. 0, Att. A.2, Page 68 For Julian Day 30, selecting COMIDA2 results # 1 of 9 For Julian Day 38, selecting COMIDA2 results # 2 of 9 For Julian Day 40, selecting COMIDA2 results # 2 of 9 For Julian Day 41, selecting COMIDA2 results # 2 of 9 For Julian Day 44, selecting COMIDA2 results # 2 of 9 For Julian Day 45, selecting COMIDA2 results # 2 of 9 For Julian Day 49, selecting COMIDA2 results # 2 of 9 For Julian Day 49, selecting COMIDA2 results # 2 of 9 For Julian Day 49, selecting COMIDA2 results # 2 of 9 For Julian Day 55, selecting COMIDA2 results # 2 of 9 For Julian Day 56, selecting COMIDA2 results # 2 of 9 For Julian Day 56, selecting COMIDA2 results # 2 of 9 For Julian Day 58, selecting COMIDA2 results # 2 of 9 For Julian Day 58, selecting COMIDA2 results # 2 of 9 For Julian Day 59, selecting COMIDA2 results # 2 of 9 For Julian Day 71, selecting COMIDA2 results # 2 of 9 For Julian Day 78, selecting COMIDA2 results # 2 of 9 For Julian Day 78, selecting COMIDA2 results # 2 of 9 For Julian Day 86, selecting COMIDA2 results # 2 of 9 For Julian Day 88, selecting COMIDA2 results # 2 of 9 For Julian Day 95, selecting COMIDA2 results # 3 of 9 For Julian Day 95, selecting COMIDA2 results # 3 of 9 For Julian Day 95, selecting COMIDA2 results # 3 of 9 For Julian Day 97, selecting COMIDA2 results # 3 of 9 For Julian Day 97, selecting COMIDA2 results # 3 of 9 For Julian Day 97, selecting COMIDA2 results # 3 of 9 For Julian Day 99, selecting COMIDA2 results # 3 of 9 For Julian Day 100, selecting COMIDA2 results # 3 of 9 For Julian Day 105, selecting COMIDA2 results # 3 of 9 For Julian Day 112, selecting COMIDA2 results # 3 of 9 For Julian Day 120, selecting COMIDA2 results # 3 of 9 For Julian Day 124, selecting COMIDA2 results # 3 of 9 For Julian Day 125, selecting COMIDA2 results # 3 of 9 For Julian Day 127, selecting COMIDA2 results # 3 of 9 For Julian Day 129, selecting COMIDA2 results # 3 of 9 For Julian Day 129, selecting COMIDA2 results # 3 of 9 For Julian Day 129, selecting COMIDA2 results # 3 of 9 For Julian Day 131, selecting COMIDA2 results # 3 of 9 For Julian Day 132, selecting COMIDA2 results # 3 of 9 For Julian Day 134, selecting COMIDA2 results # 3 of 9 For Julian Day 137, selecting COMIDA2 results # 4 of 9 For Julian Day 138, selecting COMIDA2 results # 4 of 9 For Julian Day 141, selecting COMIDA2 results # 4 of 9 For Julian Day 145, selecting COMIDA2 results # 4 of 9 For Julian Day 151, selecting COMIDA2 results # 4 of 9
Calculation IP-CALC-09-00265, Rev. 0, Att. A.2, Page 69 WARNING!! WARNING!! WARNING!! WARNING!!
THE TOTAL RELEASE DURATION EXCEEDS 20 HOURS.
THIS MAY CAUSE ERRONEOUS RESULTS TO BE PRODUCED.
WARNING!! WARNING!! WARNING!! WARNING!!
Calculation IP-CALC-09-00265, Rev. 0, Att. A.2, Page 70 WARNING!! WARNING!! WARNING!! WARNING!!
A 10 HOUR RELEASE DURATION IS BEING USED BY ATMOS FOR CALCULATING THE EXPANSION FACTOR OF PLUME # 1 INSTEAD OF THE USER-SUPPLIED 24.00 HOURS WARNING!! WARNING!! WARNING!! WARNING!!
For Julian Day 152, selecting COMIDA2 results # 4 of 9 For Julian Day 156, selecting COMIDA2 results # 4 of 9 For Julian Day 156, selecting COMIDA2 results # 4 of 9 For Julian Day 158, selecting COMIDA2 results # 4 of 9 For Julian Day 158, selecting COMIDA2 results # 4 of 9 For Julian Day 163, selecting COMIDA2 results # 4 of 9 For Julian Day 163, selecting COMIDA2 results # 4 of 9 For Julian Day 163, selecting COMIDA2 results # 4 of 9 For Julian Day 163, selecting COMIDA2 results # 4 of 9 For Julian Day 164, selecting COMIDA2 results # 4 of 9 For Julian Day 165, selecting COMIDA2 results # 4 of 9 For Julian Day 165, selecting COMIDA2 results # 4 of 9 For Julian Day 165, selecting COMIDA2 results # 4 of 9 For Julian Day 166, selecting COMIDA2 results # 4 of 9 For Julian Day 166, selecting COMIDA2 results # 4 of 9 For Julian Day 169, selecting COMIDA2 results # 5 of 9 For Julian Day 170, selecting COMIDA2 results # 5 of 9 For Julian Day 179, selecting COMIDA2 results # 5 of 9 For Julian Day 179, selecting COMIDA2 results # 5 of 9 For Julian Day 179, selecting COMIDA2 results # 5 of 9 For Julian Day 179, selecting COMIDA2 results # 5 of 9 For Julian Day 180, selecting COMIDA2 results # 5 of 9 For Julian Day 180, selecting COMIDA2 results # 5 of 9 For Julian Day 184, selecting COMIDA2 results # 5 of 9 For Julian Day 193, selecting COMIDA2 results # 6 of 9 For Julian Day 196, selecting COMIDA2 results # 6 of 9 For Julian Day 196, selecting COMIDA2 results # 6 of 9 For Julian Day 197, selecting COMIDA2 results # 6 of 9 For Julian Day 197, selecting COMIDA2 results # 6 of 9 For Julian Day 197, selecting COMIDA2 results # 6 of 9 For Julian Day 197, selecting COMIDA2 results # 6 of 9 For Julian Day 199, selecting COMIDA2 results # 6 of 9 For Julian Day 200, selecting COMIDA2 results # 6 of 9 For Julian Day 200, selecting COMIDA2 results # 6 of 9 For Julian Day 200, selecting COMIDA2 results # 6 of 9 For Julian Day 203, selecting COMIDA2 results # 6 of 9 For Julian Day 206, selecting COMIDA2 results # 6 of 9 For Julian Day 206, selecting COMIDA2 results # 6 of 9 For Julian Day 208, selecting COMIDA2 results # 6 of 9 For Julian Day 212, selecting COMIDA2 results # 6 of 9 For Julian Day 212, selecting COMIDA2 results # 6 of 9 For Julian Day 212, selecting COMIDA2 results # 6 of 9 For Julian Day 213, selecting COMIDA2 results # 6 of 9 For Julian Day 216, selecting COMIDA2 results # 6 of 9 For Julian Day 216, selecting COMIDA2 results # 6 of 9 For Julian Day 218, selecting COMIDA2 results # 6 of 9 For Julian Day 219, selecting COMIDA2 results # 6 of 9 For Julian Day 219, selecting COMIDA2 results # 6 of 9 For Julian Day 219, selecting COMIDA2 results # 6 of 9 For Julian Day 228, selecting COMIDA2 results # 7 of 9 For Julian Day 228, selecting COMIDA2 results # 7 of 9
Calculation IP-CALC-09-00265, Rev. 0, Att. A.2, Page 71 For Julian Day 228, selecting COMIDA2 results # 7 of 9 For Julian Day 229, selecting COMIDA2 results # 7 of 9 For Julian Day 229, selecting COMIDA2 results # 7 of 9 For Julian Day 229, selecting COMIDA2 results # 7 of 9 For Julian Day 245, selecting COMIDA2 results # 7 of 9 For Julian Day 246, selecting COMIDA2 results # 7 of 9 For Julian Day 250, selecting COMIDA2 results # 7 of 9 For Julian Day 251, selecting COMIDA2 results # 7 of 9 For Julian Day 256, selecting COMIDA2 results # 7 of 9 For Julian Day 257, selecting COMIDA2 results # 8 of 9 For Julian Day 258, selecting COMIDA2 results # 8 of 9 For Julian Day 258, selecting COMIDA2 results # 8 of 9 For Julian Day 258, selecting COMIDA2 results # 8 of 9 For Julian Day 258, selecting COMIDA2 results # 8 of 9 For Julian Day 259, selecting COMIDA2 results # 8 of 9 For Julian Day 260, selecting COMIDA2 results # 8 of 9 For Julian Day 263, selecting COMIDA2 results # 8 of 9 For Julian Day 263, selecting COMIDA2 results # 8 of 9 For Julian Day 263, selecting COMIDA2 results # 8 of 9 For Julian Day 264, selecting COMIDA2 results # 8 of 9 For Julian Day 271, selecting COMIDA2 results # 8 of 9 For Julian Day 272, selecting COMIDA2 results # 8 of 9 For Julian Day 273, selecting COMIDA2 results # 8 of 9 For Julian Day 276, selecting COMIDA2 results # 8 of 9 For Julian Day 282, selecting COMIDA2 results # 8 of 9 For Julian Day 284, selecting COMIDA2 results # 8 of 9 For Julian Day 288, selecting COMIDA2 results # 9 of 9 For Julian Day 295, selecting COMIDA2 results # 9 of 9 For Julian Day 299, selecting COMIDA2 results # 9 of 9 For Julian Day 301, selecting COMIDA2 results # 9 of 9 For Julian Day 302, selecting COMIDA2 results # 9 of 9 For Julian Day 311, selecting COMIDA2 results # 9 of 9 For Julian Day 314, selecting COMIDA2 results # 9 of 9 For Julian Day 314, selecting COMIDA2 results # 9 of 9 For Julian Day 314, selecting COMIDA2 results # 9 of 9 For Julian Day 315, selecting COMIDA2 results # 9 of 9 For Julian Day 319, selecting COMIDA2 results # 9 of 9 For Julian Day 319, selecting COMIDA2 results # 9 of 9 For Julian Day 331, selecting COMIDA2 results # 9 of 9 For Julian Day 334, selecting COMIDA2 results # 1 of 9 For Julian Day 339, selecting COMIDA2 results # 1 of 9 For Julian Day 347, selecting COMIDA2 results # 1 of 9 For Julian Day 349, selecting COMIDA2 results # 1 of 9 For Julian Day 352, selecting COMIDA2 results # 1 of 9 For Julian Day 363, selecting COMIDA2 results # 1 of 9 For Julian Day 364, selecting COMIDA2 results # 1 of 9 For Julian Day 365, selecting COMIDA2 results # 1 of 9 For Julian Day 4, selecting COMIDA2 results # 1 of 9 For Julian Day 9, selecting COMIDA2 results # 1 of 9 For Julian Day 10, selecting COMIDA2 results # 1 of 9 For Julian Day 10, selecting COMIDA2 results # 1 of 9 For Julian Day 10, selecting COMIDA2 results # 1 of 9 For Julian Day 10, selecting COMIDA2 results # 1 of 9 For Julian Day 11, selecting COMIDA2 results # 1 of 9 For Julian Day 13, selecting COMIDA2 results # 1 of 9 For Julian Day 14, selecting COMIDA2 results # 1 of 9 For Julian Day 16, selecting COMIDA2 results # 1 of 9 For Julian Day 22, selecting COMIDA2 results # 1 of 9 For Julian Day 25, selecting COMIDA2 results # 1 of 9
Calculation IP-CALC-09-00265, Rev. 0, Att. A.2, Page 72 For Julian Day 30, selecting COMIDA2 results # 1 of 9 For Julian Day 38, selecting COMIDA2 results # 2 of 9 For Julian Day 40, selecting COMIDA2 results # 2 of 9 For Julian Day 41, selecting COMIDA2 results # 2 of 9 For Julian Day 44, selecting COMIDA2 results # 2 of 9 For Julian Day 45, selecting COMIDA2 results # 2 of 9 For Julian Day 49, selecting COMIDA2 results # 2 of 9 For Julian Day 49, selecting COMIDA2 results # 2 of 9 For Julian Day 49, selecting COMIDA2 results # 2 of 9 For Julian Day 55, selecting COMIDA2 results # 2 of 9 For Julian Day 56, selecting COMIDA2 results # 2 of 9 For Julian Day 56, selecting COMIDA2 results # 2 of 9 For Julian Day 58, selecting COMIDA2 results # 2 of 9 For Julian Day 58, selecting COMIDA2 results # 2 of 9 For Julian Day 59, selecting COMIDA2 results # 2 of 9 For Julian Day 71, selecting COMIDA2 results # 2 of 9 For Julian Day 78, selecting COMIDA2 results # 2 of 9 For Julian Day 78, selecting COMIDA2 results # 2 of 9 For Julian Day 86, selecting COMIDA2 results # 2 of 9 For Julian Day 88, selecting COMIDA2 results # 2 of 9 For Julian Day 95, selecting COMIDA2 results # 3 of 9 For Julian Day 95, selecting COMIDA2 results # 3 of 9 For Julian Day 95, selecting COMIDA2 results # 3 of 9 For Julian Day 97, selecting COMIDA2 results # 3 of 9 For Julian Day 97, selecting COMIDA2 results # 3 of 9 For Julian Day 97, selecting COMIDA2 results # 3 of 9 For Julian Day 99, selecting COMIDA2 results # 3 of 9 For Julian Day 100, selecting COMIDA2 results # 3 of 9 For Julian Day 105, selecting COMIDA2 results # 3 of 9 For Julian Day 112, selecting COMIDA2 results # 3 of 9 For Julian Day 120, selecting COMIDA2 results # 3 of 9 For Julian Day 124, selecting COMIDA2 results # 3 of 9 For Julian Day 125, selecting COMIDA2 results # 3 of 9 For Julian Day 127, selecting COMIDA2 results # 3 of 9 For Julian Day 129, selecting COMIDA2 results # 3 of 9 For Julian Day 129, selecting COMIDA2 results # 3 of 9 For Julian Day 129, selecting COMIDA2 results # 3 of 9 For Julian Day 131, selecting COMIDA2 results # 3 of 9 For Julian Day 132, selecting COMIDA2 results # 3 of 9 For Julian Day 134, selecting COMIDA2 results # 3 of 9 For Julian Day 137, selecting COMIDA2 results # 4 of 9 For Julian Day 138, selecting COMIDA2 results # 4 of 9 For Julian Day 141, selecting COMIDA2 results # 4 of 9 For Julian Day 145, selecting COMIDA2 results # 4 of 9 For Julian Day 151, selecting COMIDA2 results # 4 of 9
Calculation IP-CALC-09-00265, Rev. 0, Att. A.2, Page 73 WARNING!! WARNING!! WARNING!! WARNING!!
THE TOTAL RELEASE DURATION EXCEEDS 20 HOURS.
THIS MAY CAUSE ERRONEOUS RESULTS TO BE PRODUCED.
WARNING!! WARNING!! WARNING!! WARNING!!
Calculation IP-CALC-09-00265, Rev. 0, Att. A.2, Page 74 WARNING!! WARNING!! WARNING!! WARNING!!
A 10 HOUR RELEASE DURATION IS BEING USED BY ATMOS FOR CALCULATING THE EXPANSION FACTOR OF PLUME # 1 INSTEAD OF THE USER-SUPPLIED 24.00 HOURS WARNING!! WARNING!! WARNING!! WARNING!!
For Julian Day 152, selecting COMIDA2 results # 4 of 9 For Julian Day 156, selecting COMIDA2 results # 4 of 9 For Julian Day 156, selecting COMIDA2 results # 4 of 9 For Julian Day 158, selecting COMIDA2 results # 4 of 9 For Julian Day 158, selecting COMIDA2 results # 4 of 9 For Julian Day 163, selecting COMIDA2 results # 4 of 9 For Julian Day 163, selecting COMIDA2 results # 4 of 9 For Julian Day 163, selecting COMIDA2 results # 4 of 9 For Julian Day 163, selecting COMIDA2 results # 4 of 9 For Julian Day 164, selecting COMIDA2 results # 4 of 9 For Julian Day 165, selecting COMIDA2 results # 4 of 9 For Julian Day 165, selecting COMIDA2 results # 4 of 9 For Julian Day 165, selecting COMIDA2 results # 4 of 9 For Julian Day 166, selecting COMIDA2 results # 4 of 9 For Julian Day 166, selecting COMIDA2 results # 4 of 9 For Julian Day 169, selecting COMIDA2 results # 5 of 9 For Julian Day 170, selecting COMIDA2 results # 5 of 9 For Julian Day 179, selecting COMIDA2 results # 5 of 9 For Julian Day 179, selecting COMIDA2 results # 5 of 9 For Julian Day 179, selecting COMIDA2 results # 5 of 9 For Julian Day 179, selecting COMIDA2 results # 5 of 9 For Julian Day 180, selecting COMIDA2 results # 5 of 9 For Julian Day 180, selecting COMIDA2 results # 5 of 9 For Julian Day 184, selecting COMIDA2 results # 5 of 9 For Julian Day 193, selecting COMIDA2 results # 6 of 9 For Julian Day 196, selecting COMIDA2 results # 6 of 9 For Julian Day 196, selecting COMIDA2 results # 6 of 9 For Julian Day 197, selecting COMIDA2 results # 6 of 9 For Julian Day 197, selecting COMIDA2 results # 6 of 9 For Julian Day 197, selecting COMIDA2 results # 6 of 9 For Julian Day 197, selecting COMIDA2 results # 6 of 9 For Julian Day 199, selecting COMIDA2 results # 6 of 9 For Julian Day 200, selecting COMIDA2 results # 6 of 9 For Julian Day 200, selecting COMIDA2 results # 6 of 9 For Julian Day 200, selecting COMIDA2 results # 6 of 9 For Julian Day 203, selecting COMIDA2 results # 6 of 9 For Julian Day 206, selecting COMIDA2 results # 6 of 9 For Julian Day 206, selecting COMIDA2 results # 6 of 9 For Julian Day 208, selecting COMIDA2 results # 6 of 9 For Julian Day 212, selecting COMIDA2 results # 6 of 9 For Julian Day 212, selecting COMIDA2 results # 6 of 9 For Julian Day 212, selecting COMIDA2 results # 6 of 9 For Julian Day 213, selecting COMIDA2 results # 6 of 9 For Julian Day 216, selecting COMIDA2 results # 6 of 9 For Julian Day 216, selecting COMIDA2 results # 6 of 9 For Julian Day 218, selecting COMIDA2 results # 6 of 9 For Julian Day 219, selecting COMIDA2 results # 6 of 9 For Julian Day 219, selecting COMIDA2 results # 6 of 9 For Julian Day 219, selecting COMIDA2 results # 6 of 9 For Julian Day 228, selecting COMIDA2 results # 7 of 9 For Julian Day 228, selecting COMIDA2 results # 7 of 9
Calculation IP-CALC-09-00265, Rev. 0, Att. A.2, Page 75 For Julian Day 228, selecting COMIDA2 results # 7 of 9 For Julian Day 229, selecting COMIDA2 results # 7 of 9 For Julian Day 229, selecting COMIDA2 results # 7 of 9 For Julian Day 229, selecting COMIDA2 results # 7 of 9 For Julian Day 245, selecting COMIDA2 results # 7 of 9 For Julian Day 246, selecting COMIDA2 results # 7 of 9 For Julian Day 250, selecting COMIDA2 results # 7 of 9 For Julian Day 251, selecting COMIDA2 results # 7 of 9 For Julian Day 256, selecting COMIDA2 results # 7 of 9 For Julian Day 257, selecting COMIDA2 results # 8 of 9 For Julian Day 258, selecting COMIDA2 results # 8 of 9 For Julian Day 258, selecting COMIDA2 results # 8 of 9 For Julian Day 258, selecting COMIDA2 results # 8 of 9 For Julian Day 258, selecting COMIDA2 results # 8 of 9 For Julian Day 259, selecting COMIDA2 results # 8 of 9 For Julian Day 260, selecting COMIDA2 results # 8 of 9 For Julian Day 263, selecting COMIDA2 results # 8 of 9 For Julian Day 263, selecting COMIDA2 results # 8 of 9 For Julian Day 263, selecting COMIDA2 results # 8 of 9 For Julian Day 264, selecting COMIDA2 results # 8 of 9 For Julian Day 271, selecting COMIDA2 results # 8 of 9 For Julian Day 272, selecting COMIDA2 results # 8 of 9 For Julian Day 273, selecting COMIDA2 results # 8 of 9 For Julian Day 276, selecting COMIDA2 results # 8 of 9 For Julian Day 282, selecting COMIDA2 results # 8 of 9 For Julian Day 284, selecting COMIDA2 results # 8 of 9 For Julian Day 288, selecting COMIDA2 results # 9 of 9 For Julian Day 295, selecting COMIDA2 results # 9 of 9 For Julian Day 299, selecting COMIDA2 results # 9 of 9 For Julian Day 301, selecting COMIDA2 results # 9 of 9 For Julian Day 302, selecting COMIDA2 results # 9 of 9 For Julian Day 311, selecting COMIDA2 results # 9 of 9 For Julian Day 314, selecting COMIDA2 results # 9 of 9 For Julian Day 314, selecting COMIDA2 results # 9 of 9 For Julian Day 314, selecting COMIDA2 results # 9 of 9 For Julian Day 315, selecting COMIDA2 results # 9 of 9 For Julian Day 319, selecting COMIDA2 results # 9 of 9 For Julian Day 319, selecting COMIDA2 results # 9 of 9 For Julian Day 331, selecting COMIDA2 results # 9 of 9 For Julian Day 334, selecting COMIDA2 results # 1 of 9 For Julian Day 339, selecting COMIDA2 results # 1 of 9 For Julian Day 347, selecting COMIDA2 results # 1 of 9 For Julian Day 349, selecting COMIDA2 results # 1 of 9 For Julian Day 352, selecting COMIDA2 results # 1 of 9 For Julian Day 363, selecting COMIDA2 results # 1 of 9 For Julian Day 364, selecting COMIDA2 results # 1 of 9 For Julian Day 365, selecting COMIDA2 results # 1 of 9 For Julian Day 4, selecting COMIDA2 results # 1 of 9 For Julian Day 9, selecting COMIDA2 results # 1 of 9 For Julian Day 10, selecting COMIDA2 results # 1 of 9 For Julian Day 10, selecting COMIDA2 results # 1 of 9 For Julian Day 10, selecting COMIDA2 results # 1 of 9 For Julian Day 10, selecting COMIDA2 results # 1 of 9 For Julian Day 11, selecting COMIDA2 results # 1 of 9 For Julian Day 13, selecting COMIDA2 results # 1 of 9 For Julian Day 14, selecting COMIDA2 results # 1 of 9 For Julian Day 16, selecting COMIDA2 results # 1 of 9 For Julian Day 22, selecting COMIDA2 results # 1 of 9 For Julian Day 25, selecting COMIDA2 results # 1 of 9
Calculation IP-CALC-09-00265, Rev. 0, Att. A.2, Page 76 For Julian Day 30, selecting COMIDA2 results # 1 of 9 For Julian Day 38, selecting COMIDA2 results # 2 of 9 For Julian Day 40, selecting COMIDA2 results # 2 of 9 For Julian Day 41, selecting COMIDA2 results # 2 of 9 For Julian Day 44, selecting COMIDA2 results # 2 of 9 For Julian Day 45, selecting COMIDA2 results # 2 of 9 For Julian Day 49, selecting COMIDA2 results # 2 of 9 For Julian Day 49, selecting COMIDA2 results # 2 of 9 For Julian Day 49, selecting COMIDA2 results # 2 of 9 For Julian Day 55, selecting COMIDA2 results # 2 of 9 For Julian Day 56, selecting COMIDA2 results # 2 of 9 For Julian Day 56, selecting COMIDA2 results # 2 of 9 For Julian Day 58, selecting COMIDA2 results # 2 of 9 For Julian Day 58, selecting COMIDA2 results # 2 of 9 For Julian Day 59, selecting COMIDA2 results # 2 of 9 For Julian Day 71, selecting COMIDA2 results # 2 of 9 For Julian Day 78, selecting COMIDA2 results # 2 of 9 For Julian Day 78, selecting COMIDA2 results # 2 of 9 For Julian Day 86, selecting COMIDA2 results # 2 of 9 For Julian Day 88, selecting COMIDA2 results # 2 of 9 For Julian Day 95, selecting COMIDA2 results # 3 of 9 For Julian Day 95, selecting COMIDA2 results # 3 of 9 For Julian Day 95, selecting COMIDA2 results # 3 of 9 For Julian Day 97, selecting COMIDA2 results # 3 of 9 For Julian Day 97, selecting COMIDA2 results # 3 of 9 For Julian Day 97, selecting COMIDA2 results # 3 of 9 For Julian Day 99, selecting COMIDA2 results # 3 of 9 For Julian Day 100, selecting COMIDA2 results # 3 of 9 For Julian Day 105, selecting COMIDA2 results # 3 of 9 For Julian Day 112, selecting COMIDA2 results # 3 of 9 For Julian Day 120, selecting COMIDA2 results # 3 of 9 For Julian Day 124, selecting COMIDA2 results # 3 of 9 For Julian Day 125, selecting COMIDA2 results # 3 of 9 For Julian Day 127, selecting COMIDA2 results # 3 of 9 For Julian Day 129, selecting COMIDA2 results # 3 of 9 For Julian Day 129, selecting COMIDA2 results # 3 of 9 For Julian Day 129, selecting COMIDA2 results # 3 of 9 For Julian Day 131, selecting COMIDA2 results # 3 of 9 For Julian Day 132, selecting COMIDA2 results # 3 of 9 For Julian Day 134, selecting COMIDA2 results # 3 of 9 For Julian Day 137, selecting COMIDA2 results # 4 of 9 For Julian Day 138, selecting COMIDA2 results # 4 of 9 For Julian Day 141, selecting COMIDA2 results # 4 of 9 For Julian Day 145, selecting COMIDA2 results # 4 of 9 For Julian Day 151, selecting COMIDA2 results # 4 of 9
Calculation IP-CALC-09-00265, Rev. 0, Att. A.2, Page 77 WARNING!! WARNING!! WARNING!! WARNING!!
THE TOTAL RELEASE DURATION EXCEEDS 20 HOURS.
THIS MAY CAUSE ERRONEOUS RESULTS TO BE PRODUCED.
WARNING!! WARNING!! WARNING!! WARNING!!
Calculation IP-CALC-09-00265, Rev. 0, Att. A.2, Page 78 WARNING!! WARNING!! WARNING!! WARNING!!
A 10 HOUR RELEASE DURATION IS BEING USED BY ATMOS FOR CALCULATING THE EXPANSION FACTOR OF PLUME # 1 INSTEAD OF THE USER-SUPPLIED 24.00 HOURS WARNING!! WARNING!! WARNING!! WARNING!!
For Julian Day 152, selecting COMIDA2 results # 4 of 9 For Julian Day 156, selecting COMIDA2 results # 4 of 9 For Julian Day 156, selecting COMIDA2 results # 4 of 9 For Julian Day 158, selecting COMIDA2 results # 4 of 9 For Julian Day 158, selecting COMIDA2 results # 4 of 9 For Julian Day 163, selecting COMIDA2 results # 4 of 9 For Julian Day 163, selecting COMIDA2 results # 4 of 9 For Julian Day 163, selecting COMIDA2 results # 4 of 9 For Julian Day 163, selecting COMIDA2 results # 4 of 9 For Julian Day 164, selecting COMIDA2 results # 4 of 9 For Julian Day 165, selecting COMIDA2 results # 4 of 9 For Julian Day 165, selecting COMIDA2 results # 4 of 9 For Julian Day 165, selecting COMIDA2 results # 4 of 9 For Julian Day 166, selecting COMIDA2 results # 4 of 9 For Julian Day 166, selecting COMIDA2 results # 4 of 9 For Julian Day 169, selecting COMIDA2 results # 5 of 9 For Julian Day 170, selecting COMIDA2 results # 5 of 9 For Julian Day 179, selecting COMIDA2 results # 5 of 9 For Julian Day 179, selecting COMIDA2 results # 5 of 9 For Julian Day 179, selecting COMIDA2 results # 5 of 9 For Julian Day 179, selecting COMIDA2 results # 5 of 9 For Julian Day 180, selecting COMIDA2 results # 5 of 9 For Julian Day 180, selecting COMIDA2 results # 5 of 9 For Julian Day 184, selecting COMIDA2 results # 5 of 9 For Julian Day 193, selecting COMIDA2 results # 6 of 9 For Julian Day 196, selecting COMIDA2 results # 6 of 9 For Julian Day 196, selecting COMIDA2 results # 6 of 9 For Julian Day 197, selecting COMIDA2 results # 6 of 9 For Julian Day 197, selecting COMIDA2 results # 6 of 9 For Julian Day 197, selecting COMIDA2 results # 6 of 9 For Julian Day 197, selecting COMIDA2 results # 6 of 9 For Julian Day 199, selecting COMIDA2 results # 6 of 9 For Julian Day 200, selecting COMIDA2 results # 6 of 9 For Julian Day 200, selecting COMIDA2 results # 6 of 9 For Julian Day 200, selecting COMIDA2 results # 6 of 9 For Julian Day 203, selecting COMIDA2 results # 6 of 9 For Julian Day 206, selecting COMIDA2 results # 6 of 9 For Julian Day 206, selecting COMIDA2 results # 6 of 9 For Julian Day 208, selecting COMIDA2 results # 6 of 9 For Julian Day 212, selecting COMIDA2 results # 6 of 9 For Julian Day 212, selecting COMIDA2 results # 6 of 9 For Julian Day 212, selecting COMIDA2 results # 6 of 9 For Julian Day 213, selecting COMIDA2 results # 6 of 9 For Julian Day 216, selecting COMIDA2 results # 6 of 9 For Julian Day 216, selecting COMIDA2 results # 6 of 9 For Julian Day 218, selecting COMIDA2 results # 6 of 9 For Julian Day 219, selecting COMIDA2 results # 6 of 9 For Julian Day 219, selecting COMIDA2 results # 6 of 9 For Julian Day 219, selecting COMIDA2 results # 6 of 9 For Julian Day 228, selecting COMIDA2 results # 7 of 9 For Julian Day 228, selecting COMIDA2 results # 7 of 9
Calculation IP-CALC-09-00265, Rev. 0, Att. A.2, Page 79 For Julian Day 228, selecting COMIDA2 results # 7 of 9 For Julian Day 229, selecting COMIDA2 results # 7 of 9 For Julian Day 229, selecting COMIDA2 results # 7 of 9 For Julian Day 229, selecting COMIDA2 results # 7 of 9 For Julian Day 245, selecting COMIDA2 results # 7 of 9 For Julian Day 246, selecting COMIDA2 results # 7 of 9 For Julian Day 250, selecting COMIDA2 results # 7 of 9 For Julian Day 251, selecting COMIDA2 results # 7 of 9 For Julian Day 256, selecting COMIDA2 results # 7 of 9 For Julian Day 257, selecting COMIDA2 results # 8 of 9 For Julian Day 258, selecting COMIDA2 results # 8 of 9 For Julian Day 258, selecting COMIDA2 results # 8 of 9 For Julian Day 258, selecting COMIDA2 results # 8 of 9 For Julian Day 258, selecting COMIDA2 results # 8 of 9 For Julian Day 259, selecting COMIDA2 results # 8 of 9 For Julian Day 260, selecting COMIDA2 results # 8 of 9 For Julian Day 263, selecting COMIDA2 results # 8 of 9 For Julian Day 263, selecting COMIDA2 results # 8 of 9 For Julian Day 263, selecting COMIDA2 results # 8 of 9 For Julian Day 264, selecting COMIDA2 results # 8 of 9 For Julian Day 271, selecting COMIDA2 results # 8 of 9 For Julian Day 272, selecting COMIDA2 results # 8 of 9 For Julian Day 273, selecting COMIDA2 results # 8 of 9 For Julian Day 276, selecting COMIDA2 results # 8 of 9 For Julian Day 282, selecting COMIDA2 results # 8 of 9 For Julian Day 284, selecting COMIDA2 results # 8 of 9 For Julian Day 288, selecting COMIDA2 results # 9 of 9 For Julian Day 295, selecting COMIDA2 results # 9 of 9 For Julian Day 299, selecting COMIDA2 results # 9 of 9 For Julian Day 301, selecting COMIDA2 results # 9 of 9 For Julian Day 302, selecting COMIDA2 results # 9 of 9 For Julian Day 311, selecting COMIDA2 results # 9 of 9 For Julian Day 314, selecting COMIDA2 results # 9 of 9 For Julian Day 314, selecting COMIDA2 results # 9 of 9 For Julian Day 314, selecting COMIDA2 results # 9 of 9 For Julian Day 315, selecting COMIDA2 results # 9 of 9 For Julian Day 319, selecting COMIDA2 results # 9 of 9 For Julian Day 319, selecting COMIDA2 results # 9 of 9 For Julian Day 331, selecting COMIDA2 results # 9 of 9 For Julian Day 334, selecting COMIDA2 results # 1 of 9 For Julian Day 339, selecting COMIDA2 results # 1 of 9 For Julian Day 347, selecting COMIDA2 results # 1 of 9 For Julian Day 349, selecting COMIDA2 results # 1 of 9 For Julian Day 352, selecting COMIDA2 results # 1 of 9 For Julian Day 363, selecting COMIDA2 results # 1 of 9 For Julian Day 364, selecting COMIDA2 results # 1 of 9 For Julian Day 365, selecting COMIDA2 results # 1 of 9 For Julian Day 4, selecting COMIDA2 results # 1 of 9 For Julian Day 9, selecting COMIDA2 results # 1 of 9 For Julian Day 10, selecting COMIDA2 results # 1 of 9 For Julian Day 10, selecting COMIDA2 results # 1 of 9 For Julian Day 10, selecting COMIDA2 results # 1 of 9 For Julian Day 10, selecting COMIDA2 results # 1 of 9 For Julian Day 11, selecting COMIDA2 results # 1 of 9 For Julian Day 13, selecting COMIDA2 results # 1 of 9 For Julian Day 14, selecting COMIDA2 results # 1 of 9 For Julian Day 16, selecting COMIDA2 results # 1 of 9 For Julian Day 22, selecting COMIDA2 results # 1 of 9 For Julian Day 25, selecting COMIDA2 results # 1 of 9
Calculation IP-CALC-09-00265, Rev. 0, Att. A.2, Page 80 For Julian Day 30, selecting COMIDA2 results # 1 of 9 For Julian Day 38, selecting COMIDA2 results # 2 of 9 For Julian Day 40, selecting COMIDA2 results # 2 of 9 For Julian Day 41, selecting COMIDA2 results # 2 of 9 For Julian Day 44, selecting COMIDA2 results # 2 of 9 For Julian Day 45, selecting COMIDA2 results # 2 of 9 For Julian Day 49, selecting COMIDA2 results # 2 of 9 For Julian Day 49, selecting COMIDA2 results # 2 of 9 For Julian Day 49, selecting COMIDA2 results # 2 of 9 For Julian Day 55, selecting COMIDA2 results # 2 of 9 For Julian Day 56, selecting COMIDA2 results # 2 of 9 For Julian Day 56, selecting COMIDA2 results # 2 of 9 For Julian Day 58, selecting COMIDA2 results # 2 of 9 For Julian Day 58, selecting COMIDA2 results # 2 of 9 For Julian Day 59, selecting COMIDA2 results # 2 of 9 For Julian Day 71, selecting COMIDA2 results # 2 of 9 For Julian Day 78, selecting COMIDA2 results # 2 of 9 For Julian Day 78, selecting COMIDA2 results # 2 of 9 For Julian Day 86, selecting COMIDA2 results # 2 of 9 For Julian Day 88, selecting COMIDA2 results # 2 of 9 For Julian Day 95, selecting COMIDA2 results # 3 of 9 For Julian Day 95, selecting COMIDA2 results # 3 of 9 For Julian Day 95, selecting COMIDA2 results # 3 of 9 For Julian Day 97, selecting COMIDA2 results # 3 of 9 For Julian Day 97, selecting COMIDA2 results # 3 of 9 For Julian Day 97, selecting COMIDA2 results # 3 of 9 For Julian Day 99, selecting COMIDA2 results # 3 of 9 For Julian Day 100, selecting COMIDA2 results # 3 of 9 For Julian Day 105, selecting COMIDA2 results # 3 of 9 For Julian Day 112, selecting COMIDA2 results # 3 of 9 For Julian Day 120, selecting COMIDA2 results # 3 of 9 For Julian Day 124, selecting COMIDA2 results # 3 of 9 For Julian Day 125, selecting COMIDA2 results # 3 of 9 For Julian Day 127, selecting COMIDA2 results # 3 of 9 For Julian Day 129, selecting COMIDA2 results # 3 of 9 For Julian Day 129, selecting COMIDA2 results # 3 of 9 For Julian Day 129, selecting COMIDA2 results # 3 of 9 For Julian Day 131, selecting COMIDA2 results # 3 of 9 For Julian Day 132, selecting COMIDA2 results # 3 of 9 For Julian Day 134, selecting COMIDA2 results # 3 of 9 For Julian Day 137, selecting COMIDA2 results # 4 of 9 For Julian Day 138, selecting COMIDA2 results # 4 of 9 For Julian Day 141, selecting COMIDA2 results # 4 of 9 For Julian Day 145, selecting COMIDA2 results # 4 of 9 For Julian Day 151, selecting COMIDA2 results # 4 of 9
Calculation IP-CALC-09-00265, Rev. 0, Att. A.2, Page 81 DATE AND TIME OF RUN = MACCS2 12-NOV-09 13:50:14 VERSION 1.13.1: last revised 1/8/04, K. McFadden "ATMOS" DESCRIPTION = ATMOS INPUT FOR IPEC CALCULATIONS "EARLY" DESCRIPTION = EARLY.IN, IPEC INPUT FROM THE EVACUATION TIME ESTIMATES "CHRONC" DESCRIPTION = CHRONC.IN - IPEC, "New" COMIDA2-Based Food Model SOURCE TERM 1 OF 8:
NCF OVERALL RESULTS OBTAINED BY COMBINING 1 EMERGENCY RESPONSE COHORTS FROM "EARLY" WITH THE WEIGHTING FRACTIONS BELOW APPLIED TO THEM:
FRACTION OF THE PEOPLE COHORT 1 = NO EVACUATION, RELOCATION MODELS APPLY EVERYWHE 1.000 AND THEN MERGING THE 1 RESULTS ABOVE WITH THE SINGLE SET OF RESULTS FROM "CHRONC" DESCRIBED BELOW:
COHORT 2 = CHRONC.IN - IPEC, "New" COMIDA2-Based Food Model RESULTS WHICH ARE PRODUCED ONLY BY "EARLY" OR ONLY BY "CHRONC" ARE PRESENTED IN LATER SECTIONS.
12-NOV-09 13:50:14 PAGE 1 PROB QUANTILES PEAK PEAK PEAK NON-ZERO MEAN 50TH 90TH 95TH 99TH 99.5TH CONS PROB TRIAL HEALTH EFFECTS CASES CAN FAT/TOTAL 0-80.5 km 1.0000 3.60E+00 3.13E+00 7.08E+00 8.51E+00 1.15E+01 1.26E+01 1.57E+01 1.00E-03 98 CAN FAT/TOTAL 0-16.1 km 1.0000 1.42E+00 1.22E+00 2.49E+00 3.00E+00 3.20E+00 3.29E+00 4.58E+00 1.24E-06 147 POPULATION DOSE (Sv)
L-EDEWBODY TOT LIF 0-80.5 km 1.0000 8.04E+01 7.27E+01 1.44E+02 1.84E+02 2.53E+02 2.84E+02 3.49E+02 1.00E-03 98 POPULATION WEIGHTED RISK CAN FAT/TOTAL 0-16.1 km 1.0000 3.61E-06 3.31E-06 6.89E-06 7.74E-06 9.93E-06 1.01E-05 1.16E-05 1.24E-06 147
Calculation IP-CALC-09-00265, Rev. 0, Att. A.2, Page 82 DATE AND TIME OF RUN = MACCS2 12-NOV-09 13:50:14 VERSION 1.13.1: last revised 1/8/04, K. McFadden "ATMOS" DESCRIPTION = ATMOS INPUT FOR IPEC CALCULATIONS "EARLY" DESCRIPTION = EARLY.IN, IPEC INPUT FROM THE EVACUATION TIME ESTIMATES SOURCE TERM 1 OF 8:
NCF RESULTS FOR A SINGLE EMERGENCY RESPONSE COHORT WITHOUT ANY WEIGHTING FRACTIONS BEING APPLIED COHORT 1 = NO EVACUATION, RELOCATION MODELS APPLY EVERYWHE 12-NOV-09 13:50:14 PAGE 2 PROB QUANTILES PEAK PEAK PEAK NON-ZERO MEAN 50TH 90TH 95TH 99TH 99.5TH CONS PROB TRIAL HEALTH EFFECTS CASES ERL FAT/TOTAL 0-80.5 km 0.0000 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0 CAN FAT/TOTAL 0-80.5 km 1.0000 2.70E-01 2.49E-01 5.07E-01 6.26E-01 8.23E-01 9.01E-01 1.05E+00 1.00E-03 98 CAN FAT/TOTAL 0-16.1 km 1.0000 1.13E-01 1.06E-01 2.08E-01 2.33E-01 3.00E-01 3.04E-01 3.56E-01 1.24E-06 147 ERL FAT/TOTAL 0-16.1 km 0.0000 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0 AVERAGE INDIVIDUAL RISK ERL FAT/TOTAL 0-0.3 km 0.0000 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0 ERL FAT/TOTAL 0.3-1.6 km 0.0000 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0 ERL FAT/TOTAL 1.6-3.2 km 0.0000 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0 POPULATION DOSE (Sv)
L-EDEWBODY TOT LIF 0-80.5 km 1.0000 5.77E+00 5.32E+00 1.02E+01 1.16E+01 1.56E+01 1.78E+01 2.26E+01 1.00E-03 98 POPULATION WEIGHTED RISK ERL FAT/TOTAL 0-3.2 km 0.0000 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0 CAN FAT/TOTAL 0-16.1 km 1.0000 2.89E-07 2.65E-07 5.30E-07 5.96E-07 7.13E-07 7.27E-07 9.11E-07 1.24E-06 147
Calculation IP-CALC-09-00265, Rev. 0, Att. A.2, Page 83 DATE AND TIME OF RUN = MACCS2 12-NOV-09 13:50:14 VERSION 1.13.1: last revised 1/8/04, K. McFadden "ATMOS" DESCRIPTION = ATMOS INPUT FOR IPEC CALCULATIONS "EARLY" DESCRIPTION = EARLY.IN, IPEC INPUT FROM THE EVACUATION TIME ESTIMATES "CHRONC" DESCRIPTION = CHRONC.IN - IPEC, "New" COMIDA2-Based Food Model SOURCE TERM 1 OF 8:
NCF RESULTS FROM THE "CHRONC" MODULE ALONE COHORT 2 = CHRONC.IN - IPEC, "New" COMIDA2-Based Food Model 12-NOV-09 13:50:14 PAGE 3 PROB QUANTILES PEAK PEAK PEAK NON-ZERO MEAN 50TH 90TH 95TH 99TH 99.5TH CONS PROB TRIAL HEALTH EFFECTS CASES CAN FAT/TOTAL 0-80.5 km 1.0000 3.33E+00 3.07E+00 6.73E+00 8.36E+00 1.12E+01 1.21E+01 1.46E+01 1.00E-03 98 CAN FAT/TOTAL 0-16.1 km 1.0000 1.31E+00 1.15E+00 2.26E+00 2.56E+00 3.08E+00 3.16E+00 4.22E+00 1.24E-06 147 POPULATION DOSE (Sv)
L-EDEWBODY TOT LIF 0-80.5 km 1.0000 7.46E+01 7.05E+01 1.34E+02 1.72E+02 2.48E+02 2.81E+02 3.26E+02 1.00E-03 98 POPULATION WEIGHTED RISK CAN FAT/TOTAL 0-16.1 km 1.0000 3.32E-06 3.11E-06 6.04E-06 7.09E-06 8.15E-06 8.65E-06 1.07E-05 1.24E-06 147 L-EDEWBODY POP. DOSE (Sv) 0-80.5 km TOTAL LONG-TERM PATHWAYS DOSE 1.0000 7.46E+01 7.05E+01 1.34E+02 1.72E+02 2.48E+02 2.81E+02 3.26E+02 1.00E-03 98 LONG-TERM DIRECT EXPOSURE PATHWAYS 1.0000 7.37E+01 7.04E+01 1.34E+02 1.72E+02 2.48E+02 2.81E+02 3.26E+02 1.00E-03 98 TOTAL INGESTION PATHWAYS DOSE 1.0000 8.47E-01 3.31E-01 2.72E+00 3.18E+00 3.80E+00 4.10E+00 6.68E+00 4.53E-05 62 LONG-TERM GROUNDSHINE DOSE 1.0000 7.14E+01 6.82E+01 1.27E+02 1.62E+02 2.35E+02 2.64E+02 3.16E+02 1.00E-03 98 LONG-TERM RESUSPENSION DOSE 1.0000 2.30E+00 2.08E+00 4.58E+00 5.80E+00 7.79E+00 8.40E+00 1.02E+01 1.00E-03 98 WATER INGESTION DOSE 1.0000 4.04E-02 3.51E-02 7.41E-02 8.28E-02 1.01E-01 1.03E-01 1.23E-01 1.04E-05 146 POP.-DEPENDENT DECONTAMINATION DOSE 0.7008 1.24E-02 1.07E-02 2.58E-02 3.13E-02 4.11E-02 4.62E-02 6.95E-02 8.99E-04 85 FARM-DEPENDENT DECONTAMINATION DOSE 0.7008 1.29E-06 1.08E-06 3.02E-06 4.82E-06 5.72E-06 6.07E-06 7.21E-06 8.99E-04 85 INGESTION OF GRAINS 1.0000 2.47E-02 7.94E-03 8.11E-02 1.04E-01 1.19E-01 1.26E-01 1.90E-01 4.53E-05 62 INGESTION OF LEAF VEG 1.0000 4.54E-02 1.19E-02 1.27E-01 1.78E-01 4.14E-01 5.11E-01 8.26E-01 4.53E-05 62 INGESTION OF ROOT CROPS 1.0000 3.27E-02 1.10E-02 1.02E-01 1.14E-01 1.47E-01 1.64E-01 2.48E-01 4.53E-05 62 INGESTION OF FRUITS 1.0000 4.82E-02 1.42E-02 1.56E-01 2.07E-01 2.44E-01 2.62E-01 3.65E-01 4.53E-05 62 INGESTION OF LEGUMES 1.0000 2.80E-02 8.65E-03 9.39E-02 1.06E-01 1.24E-01 1.33E-01 2.12E-01 4.53E-05 62 INGESTION OF BEEF 1.0000 2.54E-01 8.75E-02 8.04E-01 1.02E+00 1.16E+00 1.23E+00 1.80E+00 4.87E-05 4 INGESTION OF MILK 1.0000 2.93E-01 8.65E-02 9.65E-01 1.07E+00 1.25E+00 1.34E+00 2.14E+00 4.87E-05 4 INGESTION OF POULTRY 1.0000 6.61E-02 1.89E-02 1.81E-01 2.57E-01 5.45E-01 6.14E-01 1.05E+00 4.53E-05 62 INGESTION OF OTHER MEAT CROPS 1.0000 1.50E-02 7.13E-03 3.52E-02 4.60E-02 9.99E-02 1.09E-01 1.98E-01 4.53E-05 62 ECONOMIC COST MEASURES ($) 0-80.5 km TOTAL ECONOMIC COSTS 0.9069 2.95E+05 3.04E+05 4.68E+05 9.73E+05 1.07E+06 1.11E+06 1.36E+06 5.55E-05 29 POP.-DEPENDENT COSTS 0.7008 2.79E+05 3.03E+05 4.40E+05 9.73E+05 NOT-FOUND NOT-FOUND 1.24E+06 4.62E-02 1 FARM-DEPENDENT COSTS 0.9069 1.52E+04 1.71E+03 4.39E+04 7.41E+04 1.33E+05 1.62E+05 1.64E+05 4.79E-03 77 POP.-DEPENDENT DECONTAMINATION COST 0.7008 5.97E+04 7.06E+04 9.15E+04 2.16E+05 NOT-FOUND NOT-FOUND 2.64E+05 4.62E-02 1 FARM-DEPENDENT DECONTAMINATION COST 0.7008 4.78E+01 6.38E+01 9.12E+01 1.62E+02 NOT-FOUND NOT-FOUND 2.11E+02 4.62E-02 1 POP.-DEPENDENT INTERDICTION COST 0.7008 2.20E+05 3.03E+05 4.33E+05 7.65E+05 NOT-FOUND NOT-FOUND 9.73E+05 4.62E-02 1 FARM-DEPENDENT INTERDICTION COST 0.8986 1.19E+04 1.23E+03 3.21E+04 5.33E+04 1.13E+05 1.27E+05 1.27E+05 4.79E-03 77 POP.-DEPENDENT CONDEMNATION COST 0.0000 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0 FARM-DEPENDENT CONDEMNATION COST 0.0000 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0 EMERGENCY PHASE COST 0.0000 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0 INTERMEDIATE PHASE COST 0.0000 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0
Calculation IP-CALC-09-00265, Rev. 0, Att. A.2, Page 84 12-NOV-09 13:50:14 PAGE 4 PROB QUANTILES PEAK PEAK PEAK NON-ZERO MEAN 50TH 90TH 95TH 99TH 99.5TH CONS PROB TRIAL ECONOMIC COST MEASURES ($) 0-80.5 km MILK DISPOSAL COST 0.8597 3.40E+01 1.66E+00 9.69E+01 1.62E+02 4.14E+02 5.12E+02 1.09E+04 4.53E-06 147 CROP DISPOSAL COST 0.8514 3.19E+03 2.65E+02 9.70E+03 1.50E+04 3.30E+04 3.61E+04 3.62E+04 4.79E-03 77
Calculation IP-CALC-09-00265, Rev. 0, Att. A.2, Page 85 XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX
Calculation IP-CALC-09-00265, Rev. 0, Att. A.2, Page 86 DATE AND TIME OF RUN = MACCS2 12-NOV-09 13:50:14 VERSION 1.13.1: last revised 1/8/04, K. McFadden "ATMOS" DESCRIPTION = ATMOS INPUT FOR IPEC CALCULATIONS "EARLY" DESCRIPTION = EARLY.IN, IPEC INPUT FROM THE EVACUATION TIME ESTIMATES "CHRONC" DESCRIPTION = CHRONC.IN - IPEC, "New" COMIDA2-Based Food Model SOURCE TERM 2 OF 8:
EARLY HIGH OVERALL RESULTS OBTAINED BY COMBINING 1 EMERGENCY RESPONSE COHORTS FROM "EARLY" WITH THE WEIGHTING FRACTIONS BELOW APPLIED TO THEM:
FRACTION OF THE PEOPLE COHORT 1 = NO EVACUATION, RELOCATION MODELS APPLY EVERYWHE 1.000 AND THEN MERGING THE 1 RESULTS ABOVE WITH THE SINGLE SET OF RESULTS FROM "CHRONC" DESCRIBED BELOW:
COHORT 2 = CHRONC.IN - IPEC, "New" COMIDA2-Based Food Model RESULTS WHICH ARE PRODUCED ONLY BY "EARLY" OR ONLY BY "CHRONC" ARE PRESENTED IN LATER SECTIONS.
12-NOV-09 13:50:14 PAGE 5 PROB QUANTILES PEAK PEAK PEAK NON-ZERO MEAN 50TH 90TH 95TH 99TH 99.5TH CONS PROB TRIAL HEALTH EFFECTS CASES CAN FAT/TOTAL 0-80.5 km 1.0000 3.06E+04 1.85E+04 6.89E+04 1.03E+05 1.57E+05 NOT-FOUND 1.60E+05 9.30E-03 77 CAN FAT/TOTAL 0-16.1 km 1.0000 4.66E+03 4.12E+03 7.69E+03 8.71E+03 1.08E+04 1.14E+04 1.49E+04 2.28E-04 120 POPULATION DOSE (Sv)
L-EDEWBODY TOT LIF 0-80.5 km 1.0000 5.08E+05 2.92E+05 1.19E+06 1.50E+06 2.08E+06 2.16E+06 2.55E+06 2.00E-04 43 POPULATION WEIGHTED RISK CAN FAT/TOTAL 0-16.1 km 1.0000 1.14E-02 1.06E-02 1.86E-02 2.16E-02 2.80E-02 3.06E-02 3.80E-02 2.28E-04 120
Calculation IP-CALC-09-00265, Rev. 0, Att. A.2, Page 87 DATE AND TIME OF RUN = MACCS2 12-NOV-09 13:50:14 VERSION 1.13.1: last revised 1/8/04, K. McFadden "ATMOS" DESCRIPTION = ATMOS INPUT FOR IPEC CALCULATIONS "EARLY" DESCRIPTION = EARLY.IN, IPEC INPUT FROM THE EVACUATION TIME ESTIMATES SOURCE TERM 2 OF 8:
EARLY HIGH RESULTS FOR A SINGLE EMERGENCY RESPONSE COHORT WITHOUT ANY WEIGHTING FRACTIONS BEING APPLIED COHORT 1 = NO EVACUATION, RELOCATION MODELS APPLY EVERYWHE 12-NOV-09 13:50:14 PAGE 6 PROB QUANTILES PEAK PEAK PEAK NON-ZERO MEAN 50TH 90TH 95TH 99TH 99.5TH CONS PROB TRIAL HEALTH EFFECTS CASES ERL FAT/TOTAL 0-80.5 km 0.9876 9.67E+01 4.41E+01 2.90E+02 3.20E+02 3.77E+02 4.04E+02 5.88E+02 1.33E-05 121 CAN FAT/TOTAL 0-80.5 km 1.0000 1.92E+04 1.17E+04 4.42E+04 6.22E+04 1.03E+05 NOT-FOUND 1.15E+05 9.30E-03 77 CAN FAT/TOTAL 0-16.1 km 1.0000 4.31E+03 3.73E+03 7.46E+03 8.51E+03 1.07E+04 1.13E+04 1.48E+04 2.28E-04 120 ERL FAT/TOTAL 0-16.1 km 0.9876 9.67E+01 4.41E+01 2.90E+02 3.20E+02 3.77E+02 4.04E+02 5.88E+02 1.33E-05 121 AVERAGE INDIVIDUAL RISK ERL FAT/TOTAL 0-0.3 km 0.9876 1.46E-01 1.21E-01 1.98E-01 2.01E-01 2.02E-01 2.03E-01 2.05E-01 6.28E-04 69 ERL FAT/TOTAL 0.3-1.6 km 0.8314 1.80E-02 5.13E-03 5.10E-02 5.32E-02 5.89E-02 6.15E-02 7.16E-02 6.28E-04 69 ERL FAT/TOTAL 1.6-3.2 km 0.3506 4.25E-04 0.00E+00 1.03E-03 1.59E-03 7.41E-03 8.18E-03 1.06E-02 1.23E-03 121 POPULATION DOSE (Sv)
L-EDEWBODY TOT LIF 0-80.5 km 1.0000 2.52E+05 1.42E+05 6.19E+05 8.32E+05 1.37E+06 NOT-FOUND 1.39E+06 9.30E-03 77 POPULATION WEIGHTED RISK ERL FAT/TOTAL 0-3.2 km 0.9876 5.79E-03 2.66E-03 1.74E-02 2.08E-02 2.38E-02 2.52E-02 3.48E-02 1.33E-05 121 CAN FAT/TOTAL 0-16.1 km 1.0000 1.10E-02 1.05E-02 1.81E-02 2.12E-02 2.66E-02 2.94E-02 3.80E-02 2.28E-04 120
Calculation IP-CALC-09-00265, Rev. 0, Att. A.2, Page 88 DATE AND TIME OF RUN = MACCS2 12-NOV-09 13:50:14 VERSION 1.13.1: last revised 1/8/04, K. McFadden "ATMOS" DESCRIPTION = ATMOS INPUT FOR IPEC CALCULATIONS "EARLY" DESCRIPTION = EARLY.IN, IPEC INPUT FROM THE EVACUATION TIME ESTIMATES "CHRONC" DESCRIPTION = CHRONC.IN - IPEC, "New" COMIDA2-Based Food Model SOURCE TERM 2 OF 8:
EARLY HIGH RESULTS FROM THE "CHRONC" MODULE ALONE COHORT 2 = CHRONC.IN - IPEC, "New" COMIDA2-Based Food Model 12-NOV-09 13:50:14 PAGE 7 PROB QUANTILES PEAK PEAK PEAK NON-ZERO MEAN 50TH 90TH 95TH 99TH 99.5TH CONS PROB TRIAL HEALTH EFFECTS CASES CAN FAT/TOTAL 0-80.5 km 1.0000 1.14E+04 6.21E+03 2.70E+04 3.09E+04 3.56E+04 3.78E+04 5.26E+04 2.00E-04 43 CAN FAT/TOTAL 0-16.1 km 1.0000 3.50E+02 3.25E+02 4.95E+02 5.49E+02 6.90E+02 7.06E+02 7.35E+02 2.57E-04 151 POPULATION DOSE (Sv)
L-EDEWBODY TOT LIF 0-80.5 km 1.0000 2.56E+05 1.29E+05 6.20E+05 7.69E+05 1.03E+06 1.06E+06 1.19E+06 2.00E-04 43 POPULATION WEIGHTED RISK CAN FAT/TOTAL 0-16.1 km 0.9714 3.86E-04 3.46E-04 6.58E-04 7.70E-04 1.02E-03 1.07E-03 1.28E-03 2.57E-04 151 L-EDEWBODY POP. DOSE (Sv) 0-80.5 km TOTAL LONG-TERM PATHWAYS DOSE 1.0000 2.56E+05 1.29E+05 6.20E+05 7.69E+05 1.03E+06 1.06E+06 1.19E+06 2.00E-04 43 LONG-TERM DIRECT EXPOSURE PATHWAYS 1.0000 2.07E+05 1.00E+05 5.05E+05 6.15E+05 7.43E+05 7.69E+05 9.07E+05 2.00E-04 43 TOTAL INGESTION PATHWAYS DOSE 1.0000 2.62E+03 2.42E+03 4.25E+03 5.04E+03 5.81E+03 6.18E+03 7.47E+03 4.57E-04 120 LONG-TERM GROUNDSHINE DOSE 1.0000 1.98E+05 1.00E+05 4.74E+05 5.97E+05 7.35E+05 7.58E+05 8.76E+05 2.00E-04 43 LONG-TERM RESUSPENSION DOSE 1.0000 8.99E+03 4.24E+03 2.17E+04 2.39E+04 2.99E+04 3.02E+04 3.16E+04 1.49E-04 36 WATER INGESTION DOSE 1.0000 2.47E+03 2.30E+03 3.92E+03 4.60E+03 5.65E+03 6.04E+03 7.45E+03 4.57E-04 120 POP.-DEPENDENT DECONTAMINATION DOSE 1.0000 4.60E+04 2.50E+04 1.11E+05 1.62E+05 2.32E+05 2.52E+05 3.43E+05 1.18E-03 100 FARM-DEPENDENT DECONTAMINATION DOSE 1.0000 2.80E+01 1.10E+01 7.62E+01 8.87E+01 1.11E+02 1.19E+02 1.55E+02 3.71E-04 100 INGESTION OF GRAINS 1.0000 3.48E+00 1.29E+00 8.62E+00 1.34E+01 2.10E+01 2.18E+01 3.06E+01 1.09E-05 55 INGESTION OF LEAF VEG 1.0000 2.08E+01 8.88E+00 5.37E+01 6.12E+01 7.65E+01 8.20E+01 1.21E+02 2.40E-05 69 INGESTION OF ROOT CROPS 1.0000 1.29E+01 4.93E+00 3.32E+01 3.88E+01 5.06E+01 5.16E+01 5.74E+01 8.56E-05 149 INGESTION OF FRUITS 1.0000 1.24E+01 5.11E+00 3.24E+01 4.12E+01 5.17E+01 5.29E+01 6.45E+01 1.09E-05 55 INGESTION OF LEGUMES 1.0000 2.39E+01 9.49E+00 6.26E+01 7.51E+01 1.01E+02 1.03E+02 1.15E+02 8.56E-05 149 INGESTION OF BEEF 1.0000 3.51E+01 1.12E+01 1.09E+02 1.56E+02 2.80E+02 4.20E+02 5.66E+02 8.28E-04 128 INGESTION OF MILK 1.0000 2.87E+01 1.13E+01 7.77E+01 1.23E+02 2.49E+02 5.03E+02 5.84E+02 8.28E-04 128 INGESTION OF POULTRY 1.0000 8.85E+00 3.01E+00 3.04E+01 3.82E+01 5.82E+01 6.64E+01 1.12E+02 2.40E-05 69 INGESTION OF OTHER MEAT CROPS 1.0000 3.52E+00 1.18E+00 9.92E+00 1.59E+01 3.01E+01 3.33E+01 4.70E+01 4.57E-04 90 ECONOMIC COST MEASURES ($) 0-80.5 km TOTAL ECONOMIC COSTS 1.0000 1.70E+11 9.63E+10 3.98E+11 4.97E+11 5.77E+11 6.14E+11 8.06E+11 1.18E-03 100 POP.-DEPENDENT COSTS 1.0000 1.69E+11 9.24E+10 3.98E+11 4.97E+11 5.77E+11 6.14E+11 8.06E+11 1.18E-03 100 FARM-DEPENDENT COSTS 1.0000 3.56E+08 1.82E+08 9.37E+08 1.02E+09 1.09E+09 1.12E+09 1.27E+09 1.71E-04 143 POP.-DEPENDENT DECONTAMINATION COST 1.0000 4.12E+10 1.72E+10 1.04E+11 1.11E+11 1.30E+11 1.40E+11 1.93E+11 2.00E-04 137 FARM-DEPENDENT DECONTAMINATION COST 1.0000 3.17E+07 1.37E+07 7.79E+07 8.94E+07 1.12E+08 1.20E+08 1.47E+08 7.13E-04 137 POP.-DEPENDENT INTERDICTION COST 1.0000 1.20E+11 6.31E+10 3.10E+11 3.35E+11 4.01E+11 4.33E+11 6.56E+11 1.18E-03 100 FARM-DEPENDENT INTERDICTION COST 1.0000 2.79E+08 1.05E+08 7.28E+08 7.67E+08 8.67E+08 9.14E+08 1.11E+09 1.71E-04 143 POP.-DEPENDENT CONDEMNATION COST 1.0000 8.31E+09 5.62E+09 1.33E+10 3.17E+10 5.62E+10 NOT-FOUND 6.27E+10 6.33E-03 6 FARM-DEPENDENT CONDEMNATION COST 1.0000 7.06E+06 4.49E+06 1.51E+07 2.23E+07 5.05E+07 5.11E+07 5.56E+07 1.84E-05 6 EMERGENCY PHASE COST 1.0000 9.95E+07 5.67E+07 1.98E+08 3.16E+08 4.12E+08 4.61E+08 1.52E+09 4.84E-05 146 INTERMEDIATE PHASE COST 0.0000 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0
Calculation IP-CALC-09-00265, Rev. 0, Att. A.2, Page 89 12-NOV-09 13:50:14 PAGE 8 PROB QUANTILES PEAK PEAK PEAK NON-ZERO MEAN 50TH 90TH 95TH 99TH 99.5TH CONS PROB TRIAL ECONOMIC COST MEASURES ($) 0-80.5 km MILK DISPOSAL COST 1.0000 9.65E+05 1.17E+05 2.82E+06 3.41E+06 5.00E+06 5.14E+06 6.29E+06 2.85E-05 76 CROP DISPOSAL COST 1.0000 3.77E+07 3.57E+07 5.88E+07 6.52E+07 7.49E+07 7.81E+07 8.95E+07 5.14E-04 76
Calculation IP-CALC-09-00265, Rev. 0, Att. A.2, Page 90 XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX
Calculation IP-CALC-09-00265, Rev. 0, Att. A.2, Page 91 DATE AND TIME OF RUN = MACCS2 12-NOV-09 13:50:14 VERSION 1.13.1: last revised 1/8/04, K. McFadden "ATMOS" DESCRIPTION = ATMOS INPUT FOR IPEC CALCULATIONS "EARLY" DESCRIPTION = EARLY.IN, IPEC INPUT FROM THE EVACUATION TIME ESTIMATES "CHRONC" DESCRIPTION = CHRONC.IN - IPEC, "New" COMIDA2-Based Food Model SOURCE TERM 3 OF 8:
EARLY MEDIUM OVERALL RESULTS OBTAINED BY COMBINING 1 EMERGENCY RESPONSE COHORTS FROM "EARLY" WITH THE WEIGHTING FRACTIONS BELOW APPLIED TO THEM:
FRACTION OF THE PEOPLE COHORT 1 = NO EVACUATION, RELOCATION MODELS APPLY EVERYWHE 1.000 AND THEN MERGING THE 1 RESULTS ABOVE WITH THE SINGLE SET OF RESULTS FROM "CHRONC" DESCRIBED BELOW:
COHORT 2 = CHRONC.IN - IPEC, "New" COMIDA2-Based Food Model RESULTS WHICH ARE PRODUCED ONLY BY "EARLY" OR ONLY BY "CHRONC" ARE PRESENTED IN LATER SECTIONS.
12-NOV-09 13:50:14 PAGE 9 PROB QUANTILES PEAK PEAK PEAK NON-ZERO MEAN 50TH 90TH 95TH 99TH 99.5TH CONS PROB TRIAL HEALTH EFFECTS CASES CAN FAT/TOTAL 0-80.5 km 1.0000 1.17E+04 7.80E+03 2.69E+04 3.33E+04 5.05E+04 NOT-FOUND 5.65E+04 9.30E-03 77 CAN FAT/TOTAL 0-16.1 km 1.0000 1.87E+03 1.62E+03 3.08E+03 3.40E+03 4.26E+03 4.70E+03 5.41E+03 5.71E-05 75 POPULATION DOSE (Sv)
L-EDEWBODY TOT LIF 0-80.5 km 1.0000 2.00E+05 1.17E+05 4.81E+05 6.50E+05 9.49E+05 NOT-FOUND 9.63E+05 9.30E-03 77 POPULATION WEIGHTED RISK CAN FAT/TOTAL 0-16.1 km 1.0000 4.37E-03 3.82E-03 7.30E-03 8.29E-03 1.03E-02 1.06E-02 1.31E-02 5.71E-05 75
Calculation IP-CALC-09-00265, Rev. 0, Att. A.2, Page 92 DATE AND TIME OF RUN = MACCS2 12-NOV-09 13:50:14 VERSION 1.13.1: last revised 1/8/04, K. McFadden "ATMOS" DESCRIPTION = ATMOS INPUT FOR IPEC CALCULATIONS "EARLY" DESCRIPTION = EARLY.IN, IPEC INPUT FROM THE EVACUATION TIME ESTIMATES SOURCE TERM 3 OF 8:
EARLY MEDIUM RESULTS FOR A SINGLE EMERGENCY RESPONSE COHORT WITHOUT ANY WEIGHTING FRACTIONS BEING APPLIED COHORT 1 = NO EVACUATION, RELOCATION MODELS APPLY EVERYWHE 12-NOV-09 13:50:14 PAGE 10 PROB QUANTILES PEAK PEAK PEAK NON-ZERO MEAN 50TH 90TH 95TH 99TH 99.5TH CONS PROB TRIAL HEALTH EFFECTS CASES ERL FAT/TOTAL 0-80.5 km 0.8842 9.24E+00 4.70E+00 2.40E+01 2.89E+01 3.10E+01 3.15E+01 3.61E+01 1.33E-05 121 CAN FAT/TOTAL 0-80.5 km 1.0000 6.13E+03 4.68E+03 1.18E+04 1.59E+04 2.93E+04 3.07E+04 3.85E+04 1.38E-05 147 CAN FAT/TOTAL 0-16.1 km 1.0000 1.57E+03 1.31E+03 2.56E+03 3.01E+03 3.39E+03 3.57E+03 4.97E+03 5.71E-05 75 ERL FAT/TOTAL 0-16.1 km 0.8842 9.24E+00 4.70E+00 2.40E+01 2.89E+01 3.10E+01 3.15E+01 3.61E+01 1.33E-05 121 AVERAGE INDIVIDUAL RISK ERL FAT/TOTAL 0-0.3 km 0.8842 4.34E-02 2.93E-02 1.01E-01 1.04E-01 1.11E-01 1.14E-01 1.24E-01 6.28E-04 69 ERL FAT/TOTAL 0.3-1.6 km 0.1309 6.62E-05 0.00E+00 2.18E-04 5.17E-04 1.11E-03 1.34E-03 1.96E-03 1.23E-03 121 ERL FAT/TOTAL 1.6-3.2 km 0.0000 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0 POPULATION DOSE (Sv)
L-EDEWBODY TOT LIF 0-80.5 km 1.0000 7.74E+04 5.15E+04 1.66E+05 2.49E+05 3.21E+05 3.32E+05 4.48E+05 1.38E-05 147 POPULATION WEIGHTED RISK ERL FAT/TOTAL 0-3.2 km 0.8842 5.54E-04 2.85E-04 1.14E-03 1.26E-03 1.57E-03 1.74E-03 2.17E-03 1.33E-05 121 CAN FAT/TOTAL 0-16.1 km 1.0000 4.03E-03 3.55E-03 6.65E-03 7.51E-03 9.37E-03 1.01E-02 1.27E-02 5.71E-05 75
Calculation IP-CALC-09-00265, Rev. 0, Att. A.2, Page 93 DATE AND TIME OF RUN = MACCS2 12-NOV-09 13:50:14 VERSION 1.13.1: last revised 1/8/04, K. McFadden "ATMOS" DESCRIPTION = ATMOS INPUT FOR IPEC CALCULATIONS "EARLY" DESCRIPTION = EARLY.IN, IPEC INPUT FROM THE EVACUATION TIME ESTIMATES "CHRONC" DESCRIPTION = CHRONC.IN - IPEC, "New" COMIDA2-Based Food Model SOURCE TERM 3 OF 8:
EARLY MEDIUM RESULTS FROM THE "CHRONC" MODULE ALONE COHORT 2 = CHRONC.IN - IPEC, "New" COMIDA2-Based Food Model 12-NOV-09 13:50:14 PAGE 11 PROB QUANTILES PEAK PEAK PEAK NON-ZERO MEAN 50TH 90TH 95TH 99TH 99.5TH CONS PROB TRIAL HEALTH EFFECTS CASES CAN FAT/TOTAL 0-80.5 km 1.0000 5.57E+03 2.82E+03 1.38E+04 1.80E+04 2.71E+04 NOT-FOUND 2.75E+04 9.30E-03 149 CAN FAT/TOTAL 0-16.1 km 1.0000 2.95E+02 2.70E+02 4.65E+02 5.26E+02 6.30E+02 6.81E+02 7.40E+02 3.42E-04 72 POPULATION DOSE (Sv)
L-EDEWBODY TOT LIF 0-80.5 km 1.0000 1.22E+05 6.30E+04 3.07E+05 3.79E+05 5.95E+05 NOT-FOUND 6.05E+05 9.30E-03 149 POPULATION WEIGHTED RISK CAN FAT/TOTAL 0-16.1 km 1.0000 3.40E-04 3.10E-04 5.14E-04 5.44E-04 6.23E-04 6.60E-04 7.68E-04 4.04E-06 7 L-EDEWBODY POP. DOSE (Sv) 0-80.5 km TOTAL LONG-TERM PATHWAYS DOSE 1.0000 1.22E+05 6.30E+04 3.07E+05 3.79E+05 5.95E+05 NOT-FOUND 6.05E+05 9.30E-03 149 LONG-TERM DIRECT EXPOSURE PATHWAYS 1.0000 1.09E+05 4.84E+04 2.87E+05 3.43E+05 4.92E+05 NOT-FOUND 5.49E+05 9.30E-03 149 TOTAL INGESTION PATHWAYS DOSE 1.0000 3.31E+02 2.72E+02 5.85E+02 6.73E+02 7.64E+02 7.97E+02 1.13E+03 9.24E-05 69 LONG-TERM GROUNDSHINE DOSE 1.0000 9.70E+04 4.59E+04 2.56E+05 3.22E+05 4.78E+05 NOT-FOUND 4.87E+05 9.30E-03 149 LONG-TERM RESUSPENSION DOSE 1.0000 1.22E+04 5.17E+03 3.18E+04 3.89E+04 6.09E+04 NOT-FOUND 6.21E+04 9.30E-03 149 WATER INGESTION DOSE 1.0000 1.90E+02 1.68E+02 3.17E+02 3.52E+02 4.49E+02 4.99E+02 5.78E+02 4.57E-04 120 POP.-DEPENDENT DECONTAMINATION DOSE 1.0000 1.30E+04 9.14E+03 2.64E+04 3.86E+04 5.63E+04 6.04E+04 8.54E+04 1.18E-03 100 FARM-DEPENDENT DECONTAMINATION DOSE 1.0000 7.89E+00 3.18E+00 2.22E+01 2.95E+01 3.49E+01 3.74E+01 4.79E+01 3.85E-04 100 INGESTION OF GRAINS 1.0000 4.73E+00 1.08E+00 1.38E+01 1.86E+01 2.35E+01 2.54E+01 3.41E+01 5.66E-06 13 INGESTION OF LEAF VEG 1.0000 1.33E+01 4.82E+00 3.07E+01 5.80E+01 1.03E+02 1.09E+02 1.71E+02 3.35E-05 69 INGESTION OF ROOT CROPS 1.0000 7.02E+00 2.38E+00 2.20E+01 2.57E+01 3.14E+01 3.26E+01 4.58E+01 5.66E-06 13 INGESTION OF FRUITS 1.0000 1.01E+01 3.23E+00 3.20E+01 3.62E+01 4.81E+01 5.09E+01 6.68E+01 5.66E-06 13 INGESTION OF LEGUMES 1.0000 8.61E+00 3.58E+00 2.28E+01 2.72E+01 3.15E+01 3.24E+01 4.28E+01 5.66E-06 13 INGESTION OF BEEF 1.0000 5.34E+01 2.02E+01 1.31E+02 1.64E+02 2.32E+02 2.57E+02 3.51E+02 5.66E-06 13 INGESTION OF MILK 1.0000 2.67E+01 1.11E+01 7.21E+01 9.60E+01 1.46E+02 1.73E+02 3.12E+02 8.56E-05 112 INGESTION OF POULTRY 1.0000 1.30E+01 5.40E+00 3.44E+01 4.34E+01 6.40E+01 7.12E+01 1.06E+02 3.35E-05 69 INGESTION OF OTHER MEAT CROPS 1.0000 3.79E+00 1.70E+00 9.58E+00 1.23E+01 2.08E+01 2.48E+01 3.71E+01 4.57E-04 90 ECONOMIC COST MEASURES ($) 0-80.5 km TOTAL ECONOMIC COSTS 1.0000 5.55E+10 2.73E+10 2.01E+11 2.07E+11 2.23E+11 2.30E+11 2.99E+11 1.38E-05 147 POP.-DEPENDENT COSTS 1.0000 5.53E+10 2.71E+10 2.01E+11 2.07E+11 2.23E+11 2.30E+11 2.99E+11 1.38E-05 147 FARM-DEPENDENT COSTS 1.0000 1.61E+08 6.90E+07 4.58E+08 5.60E+08 7.62E+08 8.51E+08 1.05E+09 7.13E-04 137 POP.-DEPENDENT DECONTAMINATION COST 1.0000 1.30E+10 6.50E+09 3.47E+10 5.06E+10 6.05E+10 6.54E+10 8.84E+10 6.23E-05 146 FARM-DEPENDENT DECONTAMINATION COST 1.0000 1.21E+07 5.28E+06 3.09E+07 3.29E+07 3.79E+07 4.03E+07 5.39E+07 1.96E-05 146 POP.-DEPENDENT INTERDICTION COST 1.0000 4.16E+10 1.86E+10 1.03E+11 1.15E+11 1.47E+11 1.63E+11 2.10E+11 1.38E-05 147 FARM-DEPENDENT INTERDICTION COST 1.0000 1.30E+08 4.38E+07 3.84E+08 5.06E+08 7.32E+08 7.84E+08 9.52E+08 7.13E-04 137 POP.-DEPENDENT CONDEMNATION COST 0.9938 6.64E+08 5.64E+08 1.19E+09 1.43E+09 2.10E+09 2.36E+09 4.31E+09 6.79E-06 51 FARM-DEPENDENT CONDEMNATION COST 0.9876 2.52E+05 2.11E+05 5.21E+05 6.85E+05 1.04E+06 1.10E+06 1.78E+06 2.49E-05 51 EMERGENCY PHASE COST 1.0000 2.24E+07 1.24E+07 5.76E+07 7.28E+07 1.02E+08 1.27E+08 3.77E+08 1.20E-03 92 INTERMEDIATE PHASE COST 0.0000 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0
Calculation IP-CALC-09-00265, Rev. 0, Att. A.2, Page 94 12-NOV-09 13:50:14 PAGE 12 PROB QUANTILES PEAK PEAK PEAK NON-ZERO MEAN 50TH 90TH 95TH 99TH 99.5TH CONS PROB TRIAL ECONOMIC COST MEASURES ($) 0-80.5 km MILK DISPOSAL COST 1.0000 6.07E+05 4.01E+04 1.99E+06 2.68E+06 3.76E+06 4.22E+06 6.26E+06 2.85E-05 76 CROP DISPOSAL COST 1.0000 1.78E+07 1.28E+07 4.03E+07 5.09E+07 6.44E+07 7.06E+07 8.38E+07 4.00E-04 76
Calculation IP-CALC-09-00265, Rev. 0, Att. A.2, Page 95 XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX
Calculation IP-CALC-09-00265, Rev. 0, Att. A.2, Page 96 DATE AND TIME OF RUN = MACCS2 12-NOV-09 13:50:14 VERSION 1.13.1: last revised 1/8/04, K. McFadden "ATMOS" DESCRIPTION = ATMOS INPUT FOR IPEC CALCULATIONS "EARLY" DESCRIPTION = EARLY.IN, IPEC INPUT FROM THE EVACUATION TIME ESTIMATES "CHRONC" DESCRIPTION = CHRONC.IN - IPEC, "New" COMIDA2-Based Food Model SOURCE TERM 4 OF 8:
EARLY LOW OVERALL RESULTS OBTAINED BY COMBINING 1 EMERGENCY RESPONSE COHORTS FROM "EARLY" WITH THE WEIGHTING FRACTIONS BELOW APPLIED TO THEM:
FRACTION OF THE PEOPLE COHORT 1 = NO EVACUATION, RELOCATION MODELS APPLY EVERYWHE 1.000 AND THEN MERGING THE 1 RESULTS ABOVE WITH THE SINGLE SET OF RESULTS FROM "CHRONC" DESCRIBED BELOW:
COHORT 2 = CHRONC.IN - IPEC, "New" COMIDA2-Based Food Model RESULTS WHICH ARE PRODUCED ONLY BY "EARLY" OR ONLY BY "CHRONC" ARE PRESENTED IN LATER SECTIONS.
12-NOV-09 13:50:14 PAGE 13 PROB QUANTILES PEAK PEAK PEAK NON-ZERO MEAN 50TH 90TH 95TH 99TH 99.5TH CONS PROB TRIAL HEALTH EFFECTS CASES CAN FAT/TOTAL 0-80.5 km 1.0000 2.60E+03 1.42E+03 6.23E+03 9.76E+03 1.11E+04 1.16E+04 1.44E+04 2.00E-04 43 CAN FAT/TOTAL 0-16.1 km 1.0000 3.60E+02 3.26E+02 5.72E+02 6.56E+02 7.93E+02 8.48E+02 9.34E+02 1.86E-03 74 POPULATION DOSE (Sv)
L-EDEWBODY TOT LIF 0-80.5 km 1.0000 5.21E+04 2.95E+04 1.38E+05 2.00E+05 2.25E+05 2.37E+05 3.06E+05 2.00E-04 43 POPULATION WEIGHTED RISK CAN FAT/TOTAL 0-16.1 km 1.0000 8.52E-04 7.78E-04 1.26E-03 1.43E-03 1.95E-03 2.08E-03 2.23E-03 1.86E-03 74
Calculation IP-CALC-09-00265, Rev. 0, Att. A.2, Page 97 DATE AND TIME OF RUN = MACCS2 12-NOV-09 13:50:14 VERSION 1.13.1: last revised 1/8/04, K. McFadden "ATMOS" DESCRIPTION = ATMOS INPUT FOR IPEC CALCULATIONS "EARLY" DESCRIPTION = EARLY.IN, IPEC INPUT FROM THE EVACUATION TIME ESTIMATES SOURCE TERM 4 OF 8:
EARLY LOW RESULTS FOR A SINGLE EMERGENCY RESPONSE COHORT WITHOUT ANY WEIGHTING FRACTIONS BEING APPLIED COHORT 1 = NO EVACUATION, RELOCATION MODELS APPLY EVERYWHE 12-NOV-09 13:50:14 PAGE 14 PROB QUANTILES PEAK PEAK PEAK NON-ZERO MEAN 50TH 90TH 95TH 99TH 99.5TH CONS PROB TRIAL HEALTH EFFECTS CASES ERL FAT/TOTAL 0-80.5 km 0.0000 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0 CAN FAT/TOTAL 0-80.5 km 1.0000 6.72E+02 5.42E+02 1.27E+03 1.63E+03 2.11E+03 2.19E+03 3.05E+03 1.38E-05 147 CAN FAT/TOTAL 0-16.1 km 1.0000 2.39E+02 2.15E+02 3.82E+02 4.49E+02 5.73E+02 6.22E+02 7.04E+02 1.86E-03 74 ERL FAT/TOTAL 0-16.1 km 0.0000 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0 AVERAGE INDIVIDUAL RISK ERL FAT/TOTAL 0-0.3 km 0.0000 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0 ERL FAT/TOTAL 0.3-1.6 km 0.0000 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0 ERL FAT/TOTAL 1.6-3.2 km 0.0000 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0 POPULATION DOSE (Sv)
L-EDEWBODY TOT LIF 0-80.5 km 1.0000 9.88E+03 7.57E+03 2.16E+04 3.01E+04 3.31E+04 3.46E+04 4.94E+04 1.38E-05 147 POPULATION WEIGHTED RISK ERL FAT/TOTAL 0-3.2 km 0.0000 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0 CAN FAT/TOTAL 0-16.1 km 1.0000 6.12E-04 5.55E-04 1.04E-03 1.14E-03 1.43E-03 1.57E-03 1.80E-03 1.86E-03 74
Calculation IP-CALC-09-00265, Rev. 0, Att. A.2, Page 98 DATE AND TIME OF RUN = MACCS2 12-NOV-09 13:50:14 VERSION 1.13.1: last revised 1/8/04, K. McFadden "ATMOS" DESCRIPTION = ATMOS INPUT FOR IPEC CALCULATIONS "EARLY" DESCRIPTION = EARLY.IN, IPEC INPUT FROM THE EVACUATION TIME ESTIMATES "CHRONC" DESCRIPTION = CHRONC.IN - IPEC, "New" COMIDA2-Based Food Model SOURCE TERM 4 OF 8:
EARLY LOW RESULTS FROM THE "CHRONC" MODULE ALONE COHORT 2 = CHRONC.IN - IPEC, "New" COMIDA2-Based Food Model 12-NOV-09 13:50:14 PAGE 15 PROB QUANTILES PEAK PEAK PEAK NON-ZERO MEAN 50TH 90TH 95TH 99TH 99.5TH CONS PROB TRIAL HEALTH EFFECTS CASES CAN FAT/TOTAL 0-80.5 km 1.0000 1.93E+03 9.54E+02 4.79E+03 7.24E+03 1.03E+04 1.07E+04 1.24E+04 2.00E-04 43 CAN FAT/TOTAL 0-16.1 km 1.0000 1.21E+02 1.08E+02 1.70E+02 2.02E+02 2.23E+02 2.32E+02 2.96E+02 9.80E-05 84 POPULATION DOSE (Sv)
L-EDEWBODY TOT LIF 0-80.5 km 1.0000 4.22E+04 2.10E+04 1.03E+05 1.53E+05 2.14E+05 2.23E+05 2.71E+05 2.00E-04 43 POPULATION WEIGHTED RISK CAN FAT/TOTAL 0-16.1 km 1.0000 2.40E-04 2.21E-04 3.28E-04 3.49E-04 4.03E-04 4.28E-04 5.40E-04 5.26E-05 40 L-EDEWBODY POP. DOSE (Sv) 0-80.5 km TOTAL LONG-TERM PATHWAYS DOSE 1.0000 4.22E+04 2.10E+04 1.03E+05 1.53E+05 2.14E+05 2.23E+05 2.71E+05 2.00E-04 43 LONG-TERM DIRECT EXPOSURE PATHWAYS 1.0000 4.13E+04 2.00E+04 1.03E+05 1.53E+05 2.14E+05 2.23E+05 2.71E+05 2.00E-04 43 TOTAL INGESTION PATHWAYS DOSE 1.0000 1.21E+02 6.11E+01 3.18E+02 3.50E+02 4.38E+02 4.82E+02 1.10E+03 2.85E-05 76 LONG-TERM GROUNDSHINE DOSE 1.0000 3.72E+04 1.67E+04 9.59E+04 1.33E+05 2.06E+05 2.13E+05 2.44E+05 2.00E-04 43 LONG-TERM RESUSPENSION DOSE 1.0000 4.03E+03 1.82E+03 1.03E+04 1.53E+04 2.13E+04 2.22E+04 2.66E+04 2.00E-04 43 WATER INGESTION DOSE 1.0000 2.50E+01 2.29E+01 4.08E+01 4.91E+01 5.75E+01 6.11E+01 7.62E+01 4.57E-04 120 POP.-DEPENDENT DECONTAMINATION DOSE 1.0000 8.06E+02 7.32E+02 1.31E+03 1.53E+03 2.14E+03 2.39E+03 3.10E+03 1.18E-03 100 FARM-DEPENDENT DECONTAMINATION DOSE 1.0000 4.37E-01 2.56E-01 9.22E-01 1.37E+00 2.48E+00 2.88E+00 3.59E+00 5.71E-05 120 INGESTION OF GRAINS 1.0000 3.82E+00 7.27E-01 1.15E+01 1.34E+01 1.92E+01 2.18E+01 4.21E+01 2.85E-05 76 INGESTION OF LEAF VEG 1.0000 8.78E+00 1.54E+00 2.33E+01 5.04E+01 7.58E+01 8.61E+01 2.43E+02 2.85E-05 76 INGESTION OF ROOT CROPS 1.0000 5.14E+00 9.12E-01 1.71E+01 2.12E+01 2.59E+01 2.82E+01 5.48E+01 2.85E-05 76 INGESTION OF FRUITS 1.0000 7.56E+00 1.46E+00 2.55E+01 3.11E+01 3.81E+01 4.15E+01 8.07E+01 2.85E-05 76 INGESTION OF LEGUMES 1.0000 4.73E+00 1.26E+00 1.31E+01 1.67E+01 2.29E+01 2.49E+01 4.72E+01 2.85E-05 76 INGESTION OF BEEF 1.0000 3.51E+01 1.16E+01 1.05E+02 1.22E+02 1.70E+02 1.96E+02 2.72E+02 2.85E-05 76 INGESTION OF MILK 1.0000 1.88E+01 6.70E+00 5.22E+01 5.98E+01 7.84E+01 8.64E+01 1.44E+02 2.85E-05 76 INGESTION OF POULTRY 1.0000 9.53E+00 3.33E+00 2.69E+01 3.47E+01 5.43E+01 6.11E+01 1.76E+02 2.85E-05 76 INGESTION OF OTHER MEAT CROPS 1.0000 2.20E+00 8.84E-01 5.73E+00 7.21E+00 9.39E+00 1.11E+01 3.18E+01 2.85E-05 76 ECONOMIC COST MEASURES ($) 0-80.5 km TOTAL ECONOMIC COSTS 1.0000 3.58E+09 2.78E+09 6.00E+09 6.79E+09 1.20E+10 1.57E+10 3.34E+10 1.04E-04 21 POP.-DEPENDENT COSTS 1.0000 3.53E+09 2.72E+09 5.99E+09 6.78E+09 1.20E+10 1.57E+10 3.34E+10 1.04E-04 21 FARM-DEPENDENT COSTS 1.0000 4.48E+07 1.35E+07 1.29E+08 1.71E+08 2.87E+08 3.10E+08 4.00E+08 8.56E-05 149 POP.-DEPENDENT DECONTAMINATION COST 1.0000 8.10E+08 6.27E+08 1.34E+09 1.56E+09 3.09E+09 3.98E+09 7.20E+09 1.04E-04 21 FARM-DEPENDENT DECONTAMINATION COST 1.0000 1.33E+06 4.36E+05 4.01E+06 5.12E+06 7.24E+06 7.95E+06 1.09E+07 2.90E-05 21 POP.-DEPENDENT INTERDICTION COST 1.0000 2.68E+09 1.90E+09 5.14E+09 5.78E+09 1.07E+10 1.49E+10 2.60E+10 1.04E-04 21 FARM-DEPENDENT INTERDICTION COST 1.0000 3.75E+07 6.80E+06 1.17E+08 1.47E+08 2.77E+08 3.07E+08 3.70E+08 8.56E-05 149 POP.-DEPENDENT CONDEMNATION COST 0.9584 3.34E+07 1.27E+07 1.05E+08 1.10E+08 1.25E+08 NOT-FOUND 1.25E+08 9.49E-03 4 FARM-DEPENDENT CONDEMNATION COST 0.9459 1.11E+04 4.21E+03 3.28E+04 7.08E+04 7.56E+04 NOT-FOUND 7.73E+04 5.72E-03 8 EMERGENCY PHASE COST 1.0000 1.85E+06 1.47E+06 3.67E+06 4.92E+06 6.45E+06 7.20E+06 1.23E+07 2.28E-04 120 INTERMEDIATE PHASE COST 0.0000 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0
Calculation IP-CALC-09-00265, Rev. 0, Att. A.2, Page 99 12-NOV-09 13:50:14 PAGE 16 PROB QUANTILES PEAK PEAK PEAK NON-ZERO MEAN 50TH 90TH 95TH 99TH 99.5TH CONS PROB TRIAL ECONOMIC COST MEASURES ($) 0-80.5 km MILK DISPOSAL COST 1.0000 2.53E+05 1.54E+04 9.60E+05 1.22E+06 1.99E+06 2.23E+06 3.15E+06 1.43E-04 149 CROP DISPOSAL COST 1.0000 5.69E+06 3.61E+06 1.30E+07 1.74E+07 3.55E+07 4.57E+07 4.64E+07 4.79E-03 149
Calculation IP-CALC-09-00265, Rev. 0, Att. A.2, Page 100 XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX
Calculation IP-CALC-09-00265, Rev. 0, Att. A.2, Page 101 DATE AND TIME OF RUN = MACCS2 12-NOV-09 13:50:14 VERSION 1.13.1: last revised 1/8/04, K. McFadden "ATMOS" DESCRIPTION = ATMOS INPUT FOR IPEC CALCULATIONS "EARLY" DESCRIPTION = EARLY.IN, IPEC INPUT FROM THE EVACUATION TIME ESTIMATES "CHRONC" DESCRIPTION = CHRONC.IN - IPEC, "New" COMIDA2-Based Food Model SOURCE TERM 5 OF 8:
LATE HIGH OVERALL RESULTS OBTAINED BY COMBINING 1 EMERGENCY RESPONSE COHORTS FROM "EARLY" WITH THE WEIGHTING FRACTIONS BELOW APPLIED TO THEM:
FRACTION OF THE PEOPLE COHORT 1 = NO EVACUATION, RELOCATION MODELS APPLY EVERYWHE 1.000 AND THEN MERGING THE 1 RESULTS ABOVE WITH THE SINGLE SET OF RESULTS FROM "CHRONC" DESCRIBED BELOW:
COHORT 2 = CHRONC.IN - IPEC, "New" COMIDA2-Based Food Model RESULTS WHICH ARE PRODUCED ONLY BY "EARLY" OR ONLY BY "CHRONC" ARE PRESENTED IN LATER SECTIONS.
12-NOV-09 13:50:14 PAGE 17 PROB QUANTILES PEAK PEAK PEAK NON-ZERO MEAN 50TH 90TH 95TH 99TH 99.5TH CONS PROB TRIAL HEALTH EFFECTS CASES CAN FAT/TOTAL 0-80.5 km 1.0000 7.32E+03 4.09E+03 1.65E+04 2.10E+04 2.79E+04 3.11E+04 3.73E+04 1.20E-03 23 CAN FAT/TOTAL 0-16.1 km 1.0000 6.36E+02 5.89E+02 1.03E+03 1.07E+03 1.17E+03 1.22E+03 1.57E+03 5.71E-05 90 POPULATION DOSE (Sv)
L-EDEWBODY TOT LIF 0-80.5 km 1.0000 1.63E+05 9.05E+04 4.04E+05 5.13E+05 6.43E+05 7.08E+05 8.40E+05 1.20E-03 23 POPULATION WEIGHTED RISK CAN FAT/TOTAL 0-16.1 km 1.0000 1.45E-03 1.23E-03 2.37E-03 2.72E-03 3.12E-03 3.20E-03 3.73E-03 5.71E-05 90
Calculation IP-CALC-09-00265, Rev. 0, Att. A.2, Page 102 DATE AND TIME OF RUN = MACCS2 12-NOV-09 13:50:14 VERSION 1.13.1: last revised 1/8/04, K. McFadden "ATMOS" DESCRIPTION = ATMOS INPUT FOR IPEC CALCULATIONS "EARLY" DESCRIPTION = EARLY.IN, IPEC INPUT FROM THE EVACUATION TIME ESTIMATES SOURCE TERM 5 OF 8:
LATE HIGH RESULTS FOR A SINGLE EMERGENCY RESPONSE COHORT WITHOUT ANY WEIGHTING FRACTIONS BEING APPLIED COHORT 1 = NO EVACUATION, RELOCATION MODELS APPLY EVERYWHE 12-NOV-09 13:50:14 PAGE 18 PROB QUANTILES PEAK PEAK PEAK NON-ZERO MEAN 50TH 90TH 95TH 99TH 99.5TH CONS PROB TRIAL HEALTH EFFECTS CASES ERL FAT/TOTAL 0-80.5 km 0.2844 9.35E-02 0.00E+00 3.32E-01 5.00E-01 8.97E-01 1.12E+00 2.22E+00 2.59E-04 30 CAN FAT/TOTAL 0-80.5 km 1.0000 1.65E+03 1.20E+03 3.39E+03 4.41E+03 5.89E+03 6.44E+03 7.73E+03 1.00E-03 98 CAN FAT/TOTAL 0-16.1 km 1.0000 4.18E+02 3.72E+02 7.46E+02 8.46E+02 1.02E+03 1.04E+03 1.18E+03 5.71E-05 90 ERL FAT/TOTAL 0-16.1 km 0.2844 9.35E-02 0.00E+00 3.32E-01 5.00E-01 8.97E-01 1.12E+00 2.22E+00 2.59E-04 30 AVERAGE INDIVIDUAL RISK ERL FAT/TOTAL 0-0.3 km 0.2844 4.47E-04 0.00E+00 1.54E-03 2.10E-03 3.18E-03 3.81E-03 8.16E-03 5.99E-04 30 ERL FAT/TOTAL 0.3-1.6 km 0.0000 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0 ERL FAT/TOTAL 1.6-3.2 km 0.0000 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0 POPULATION DOSE (Sv)
L-EDEWBODY TOT LIF 0-80.5 km 1.0000 3.60E+04 2.83E+04 7.97E+04 1.04E+05 1.31E+05 1.45E+05 1.84E+05 1.00E-03 98 POPULATION WEIGHTED RISK ERL FAT/TOTAL 0-3.2 km 0.2844 5.61E-06 0.00E+00 2.16E-05 3.00E-05 4.78E-05 5.72E-05 1.33E-04 2.59E-04 30 CAN FAT/TOTAL 0-16.1 km 1.0000 1.07E-03 1.01E-03 1.85E-03 2.07E-03 2.30E-03 2.40E-03 3.03E-03 5.71E-05 90
Calculation IP-CALC-09-00265, Rev. 0, Att. A.2, Page 103 DATE AND TIME OF RUN = MACCS2 12-NOV-09 13:50:14 VERSION 1.13.1: last revised 1/8/04, K. McFadden "ATMOS" DESCRIPTION = ATMOS INPUT FOR IPEC CALCULATIONS "EARLY" DESCRIPTION = EARLY.IN, IPEC INPUT FROM THE EVACUATION TIME ESTIMATES "CHRONC" DESCRIPTION = CHRONC.IN - IPEC, "New" COMIDA2-Based Food Model SOURCE TERM 5 OF 8:
LATE HIGH RESULTS FROM THE "CHRONC" MODULE ALONE COHORT 2 = CHRONC.IN - IPEC, "New" COMIDA2-Based Food Model 12-NOV-09 13:50:14 PAGE 19 PROB QUANTILES PEAK PEAK PEAK NON-ZERO MEAN 50TH 90TH 95TH 99TH 99.5TH CONS PROB TRIAL HEALTH EFFECTS CASES CAN FAT/TOTAL 0-80.5 km 1.0000 5.67E+03 2.68E+03 1.42E+04 1.90E+04 2.36E+04 2.56E+04 3.20E+04 1.20E-03 23 CAN FAT/TOTAL 0-16.1 km 1.0000 2.18E+02 2.07E+02 3.11E+02 3.23E+02 3.53E+02 3.66E+02 6.18E+02 1.73E-06 54 POPULATION DOSE (Sv)
L-EDEWBODY TOT LIF 0-80.5 km 1.0000 1.27E+05 6.04E+04 3.35E+05 3.93E+05 5.37E+05 5.86E+05 7.16E+05 1.20E-03 23 POPULATION WEIGHTED RISK CAN FAT/TOTAL 0-16.1 km 1.0000 3.84E-04 3.41E-04 6.05E-04 6.96E-04 7.45E-04 7.66E-04 1.13E-03 1.73E-06 54 L-EDEWBODY POP. DOSE (Sv) 0-80.5 km TOTAL LONG-TERM PATHWAYS DOSE 1.0000 1.27E+05 6.04E+04 3.35E+05 3.93E+05 5.37E+05 5.86E+05 7.16E+05 1.20E-03 23 LONG-TERM DIRECT EXPOSURE PATHWAYS 1.0000 1.22E+05 5.66E+04 3.19E+05 3.74E+05 5.22E+05 5.72E+05 6.90E+05 1.20E-03 23 TOTAL INGESTION PATHWAYS DOSE 1.0000 3.94E+02 3.43E+02 6.98E+02 7.34E+02 8.20E+02 8.60E+02 1.06E+03 8.82E-05 126 LONG-TERM GROUNDSHINE DOSE 1.0000 1.19E+05 5.51E+04 3.16E+05 3.71E+05 5.20E+05 5.67E+05 6.75E+05 1.20E-03 23 LONG-TERM RESUSPENSION DOSE 1.0000 2.65E+03 1.20E+03 7.18E+03 8.37E+03 1.11E+04 1.22E+04 1.47E+04 1.20E-03 67 WATER INGESTION DOSE 1.0000 3.38E+02 3.00E+02 6.09E+02 7.05E+02 7.60E+02 7.84E+02 1.03E+03 1.04E-05 146 POP.-DEPENDENT DECONTAMINATION DOSE 1.0000 4.87E+03 3.47E+03 1.06E+04 1.37E+04 2.24E+04 2.59E+04 3.42E+04 1.00E-03 98 FARM-DEPENDENT DECONTAMINATION DOSE 1.0000 3.33E+00 1.48E+00 1.01E+01 1.10E+01 1.33E+01 1.45E+01 2.01E+01 3.28E-04 98 INGESTION OF GRAINS 1.0000 1.97E+00 6.13E-01 6.59E+00 8.29E+00 1.07E+01 1.13E+01 1.64E+01 3.35E-05 51 INGESTION OF LEAF VEG 1.0000 4.27E+00 1.59E+00 1.16E+01 1.56E+01 3.06E+01 3.28E+01 4.90E+01 8.56E-05 77 INGESTION OF ROOT CROPS 1.0000 2.89E+00 1.12E+00 9.37E+00 1.07E+01 1.27E+01 1.37E+01 2.18E+01 2.40E-05 51 INGESTION OF FRUITS 1.0000 5.29E+00 2.38E+00 1.39E+01 1.99E+01 2.30E+01 2.44E+01 3.37E+01 2.40E-05 51 INGESTION OF LEGUMES 1.0000 3.23E+00 1.47E+00 9.25E+00 1.05E+01 1.20E+01 1.27E+01 2.00E+01 2.40E-05 51 INGESTION OF BEEF 1.0000 1.77E+01 7.10E+00 5.34E+01 7.45E+01 1.02E+02 1.08E+02 1.62E+02 2.29E-05 126 INGESTION OF MILK 1.0000 1.13E+01 4.00E+00 3.55E+01 5.08E+01 7.54E+01 8.26E+01 1.35E+02 2.29E-05 126 INGESTION OF POULTRY 1.0000 6.16E+00 2.47E+00 1.41E+01 1.89E+01 4.41E+01 5.12E+01 6.13E+01 8.56E-05 77 INGESTION OF OTHER MEAT CROPS 1.0000 2.98E+00 1.13E+00 1.02E+01 1.34E+01 2.07E+01 2.15E+01 2.62E+01 1.45E-04 88 ECONOMIC COST MEASURES ($) 0-80.5 km TOTAL ECONOMIC COSTS 1.0000 4.61E+10 2.21E+10 1.30E+11 2.07E+11 2.41E+11 2.57E+11 2.99E+11 1.00E-03 98 POP.-DEPENDENT COSTS 1.0000 4.58E+10 2.20E+10 1.30E+11 2.07E+11 2.41E+11 2.57E+11 2.99E+11 1.00E-03 98 FARM-DEPENDENT COSTS 1.0000 2.45E+08 1.27E+08 7.15E+08 7.70E+08 9.14E+08 9.84E+08 1.06E+09 3.27E-05 150 POP.-DEPENDENT DECONTAMINATION COST 1.0000 1.06E+10 4.93E+09 2.97E+10 3.99E+10 5.84E+10 6.45E+10 8.84E+10 1.00E-03 98 FARM-DEPENDENT DECONTAMINATION COST 1.0000 9.48E+06 3.64E+06 2.69E+07 3.19E+07 3.98E+07 4.38E+07 5.39E+07 3.16E-04 98 POP.-DEPENDENT INTERDICTION COST 1.0000 3.39E+10 1.37E+10 1.00E+11 1.14E+11 1.54E+11 1.75E+11 2.10E+11 1.00E-03 98 FARM-DEPENDENT INTERDICTION COST 1.0000 2.02E+08 6.90E+07 6.32E+08 7.15E+08 7.68E+08 7.92E+08 9.90E+08 3.27E-05 150 POP.-DEPENDENT CONDEMNATION COST 1.0000 1.28E+09 1.08E+09 2.69E+09 3.27E+09 4.53E+09 5.04E+09 5.78E+09 1.20E-04 26 FARM-DEPENDENT CONDEMNATION COST 1.0000 4.24E+05 3.43E+05 9.08E+05 1.05E+06 1.26E+06 1.36E+06 3.22E+06 2.04E-05 146 EMERGENCY PHASE COST 1.0000 7.30E+06 7.02E+06 1.15E+07 1.28E+07 1.64E+07 1.82E+07 6.87E+07 1.84E-04 145 INTERMEDIATE PHASE COST 0.0000 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0
Calculation IP-CALC-09-00265, Rev. 0, Att. A.2, Page 104 12-NOV-09 13:50:14 PAGE 20 PROB QUANTILES PEAK PEAK PEAK NON-ZERO MEAN 50TH 90TH 95TH 99TH 99.5TH CONS PROB TRIAL ECONOMIC COST MEASURES ($) 0-80.5 km MILK DISPOSAL COST 1.0000 9.07E+05 1.14E+05 2.73E+06 3.38E+06 5.02E+06 5.16E+06 6.29E+06 3.40E-05 150 CROP DISPOSAL COST 1.0000 3.18E+07 3.01E+07 5.59E+07 6.10E+07 7.10E+07 7.23E+07 8.38E+07 2.16E-05 150
Calculation IP-CALC-09-00265, Rev. 0, Att. A.2, Page 105 XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX
Calculation IP-CALC-09-00265, Rev. 0, Att. A.2, Page 106 DATE AND TIME OF RUN = MACCS2 12-NOV-09 13:50:14 VERSION 1.13.1: last revised 1/8/04, K. McFadden "ATMOS" DESCRIPTION = ATMOS INPUT FOR IPEC CALCULATIONS "EARLY" DESCRIPTION = EARLY.IN, IPEC INPUT FROM THE EVACUATION TIME ESTIMATES "CHRONC" DESCRIPTION = CHRONC.IN - IPEC, "New" COMIDA2-Based Food Model SOURCE TERM 6 OF 8:
LATE MEDIUM OVERALL RESULTS OBTAINED BY COMBINING 1 EMERGENCY RESPONSE COHORTS FROM "EARLY" WITH THE WEIGHTING FRACTIONS BELOW APPLIED TO THEM:
FRACTION OF THE PEOPLE COHORT 1 = NO EVACUATION, RELOCATION MODELS APPLY EVERYWHE 1.000 AND THEN MERGING THE 1 RESULTS ABOVE WITH THE SINGLE SET OF RESULTS FROM "CHRONC" DESCRIBED BELOW:
COHORT 2 = CHRONC.IN - IPEC, "New" COMIDA2-Based Food Model RESULTS WHICH ARE PRODUCED ONLY BY "EARLY" OR ONLY BY "CHRONC" ARE PRESENTED IN LATER SECTIONS.
12-NOV-09 13:50:14 PAGE 21 PROB QUANTILES PEAK PEAK PEAK NON-ZERO MEAN 50TH 90TH 95TH 99TH 99.5TH CONS PROB TRIAL HEALTH EFFECTS CASES CAN FAT/TOTAL 0-80.5 km 1.0000 3.14E+03 1.56E+03 7.97E+03 1.04E+04 1.41E+04 1.61E+04 2.02E+04 1.26E-03 16 CAN FAT/TOTAL 0-16.1 km 1.0000 2.91E+02 2.61E+02 5.05E+02 5.32E+02 6.00E+02 6.32E+02 7.43E+02 5.71E-05 143 POPULATION DOSE (Sv)
L-EDEWBODY TOT LIF 0-80.5 km 1.0000 6.85E+04 3.58E+04 1.75E+05 2.53E+05 3.48E+05 3.78E+05 4.47E+05 1.26E-03 16 POPULATION WEIGHTED RISK CAN FAT/TOTAL 0-16.1 km 1.0000 6.85E-04 6.11E-04 1.04E-03 1.09E-03 1.22E-03 1.28E-03 1.73E-03 5.71E-05 143
Calculation IP-CALC-09-00265, Rev. 0, Att. A.2, Page 107 DATE AND TIME OF RUN = MACCS2 12-NOV-09 13:50:14 VERSION 1.13.1: last revised 1/8/04, K. McFadden "ATMOS" DESCRIPTION = ATMOS INPUT FOR IPEC CALCULATIONS "EARLY" DESCRIPTION = EARLY.IN, IPEC INPUT FROM THE EVACUATION TIME ESTIMATES SOURCE TERM 6 OF 8:
LATE MEDIUM RESULTS FOR A SINGLE EMERGENCY RESPONSE COHORT WITHOUT ANY WEIGHTING FRACTIONS BEING APPLIED COHORT 1 = NO EVACUATION, RELOCATION MODELS APPLY EVERYWHE 12-NOV-09 13:50:14 PAGE 22 PROB QUANTILES PEAK PEAK PEAK NON-ZERO MEAN 50TH 90TH 95TH 99TH 99.5TH CONS PROB TRIAL HEALTH EFFECTS CASES ERL FAT/TOTAL 0-80.5 km 0.0000 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0 CAN FAT/TOTAL 0-80.5 km 1.0000 4.26E+02 3.61E+02 9.01E+02 1.07E+03 1.31E+03 1.43E+03 1.75E+03 1.00E-03 98 CAN FAT/TOTAL 0-16.1 km 1.0000 1.52E+02 1.30E+02 2.79E+02 3.09E+02 3.44E+02 3.60E+02 4.61E+02 1.14E-04 78 ERL FAT/TOTAL 0-16.1 km 0.0000 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0 AVERAGE INDIVIDUAL RISK ERL FAT/TOTAL 0-0.3 km 0.0000 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0 ERL FAT/TOTAL 0.3-1.6 km 0.0000 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0 ERL FAT/TOTAL 1.6-3.2 km 0.0000 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0 POPULATION DOSE (Sv)
L-EDEWBODY TOT LIF 0-80.5 km 1.0000 7.91E+03 7.09E+03 1.72E+04 2.11E+04 2.60E+04 2.84E+04 3.60E+04 1.00E-03 98 POPULATION WEIGHTED RISK ERL FAT/TOTAL 0-3.2 km 0.0000 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0 CAN FAT/TOTAL 0-16.1 km 1.0000 3.90E-04 3.46E-04 7.25E-04 7.78E-04 9.15E-04 9.81E-04 1.18E-03 1.14E-04 78
Calculation IP-CALC-09-00265, Rev. 0, Att. A.2, Page 108 DATE AND TIME OF RUN = MACCS2 12-NOV-09 13:50:14 VERSION 1.13.1: last revised 1/8/04, K. McFadden "ATMOS" DESCRIPTION = ATMOS INPUT FOR IPEC CALCULATIONS "EARLY" DESCRIPTION = EARLY.IN, IPEC INPUT FROM THE EVACUATION TIME ESTIMATES "CHRONC" DESCRIPTION = CHRONC.IN - IPEC, "New" COMIDA2-Based Food Model SOURCE TERM 6 OF 8:
LATE MEDIUM RESULTS FROM THE "CHRONC" MODULE ALONE COHORT 2 = CHRONC.IN - IPEC, "New" COMIDA2-Based Food Model 12-NOV-09 13:50:14 PAGE 23 PROB QUANTILES PEAK PEAK PEAK NON-ZERO MEAN 50TH 90TH 95TH 99TH 99.5TH CONS PROB TRIAL HEALTH EFFECTS CASES CAN FAT/TOTAL 0-80.5 km 1.0000 2.72E+03 1.28E+03 7.24E+03 9.47E+03 1.21E+04 1.32E+04 1.85E+04 3.71E-04 38 CAN FAT/TOTAL 0-16.1 km 1.0000 1.39E+02 1.18E+02 2.06E+02 2.18E+02 2.47E+02 2.61E+02 3.36E+02 9.80E-05 84 POPULATION DOSE (Sv)
L-EDEWBODY TOT LIF 0-80.5 km 1.0000 6.06E+04 2.93E+04 1.52E+05 2.16E+05 3.17E+05 3.35E+05 4.12E+05 3.71E-04 38 POPULATION WEIGHTED RISK CAN FAT/TOTAL 0-16.1 km 1.0000 2.96E-04 2.81E-04 4.49E-04 5.08E-04 5.58E-04 5.82E-04 6.94E-04 2.45E-04 84 L-EDEWBODY POP. DOSE (Sv) 0-80.5 km TOTAL LONG-TERM PATHWAYS DOSE 1.0000 6.06E+04 2.93E+04 1.52E+05 2.16E+05 3.17E+05 3.35E+05 4.12E+05 3.71E-04 38 LONG-TERM DIRECT EXPOSURE PATHWAYS 1.0000 5.97E+04 2.83E+04 1.51E+05 2.15E+05 3.16E+05 3.34E+05 4.12E+05 3.71E-04 38 TOTAL INGESTION PATHWAYS DOSE 1.0000 1.44E+02 1.14E+02 2.59E+02 3.03E+02 3.39E+02 3.55E+02 4.70E+02 8.56E-05 71 LONG-TERM GROUNDSHINE DOSE 1.0000 5.74E+04 2.56E+04 1.40E+05 2.02E+05 3.13E+05 3.29E+05 3.95E+05 3.71E-04 38 LONG-TERM RESUSPENSION DOSE 1.0000 2.33E+03 1.04E+03 6.49E+03 8.92E+03 1.15E+04 1.24E+04 1.64E+04 3.71E-04 38 WATER INGESTION DOSE 1.0000 6.40E+01 5.84E+01 1.04E+02 1.09E+02 1.22E+02 1.28E+02 1.95E+02 1.04E-05 146 POP.-DEPENDENT DECONTAMINATION DOSE 1.0000 7.19E+02 6.29E+02 1.20E+03 1.36E+03 1.81E+03 2.03E+03 2.41E+03 1.18E-03 100 FARM-DEPENDENT DECONTAMINATION DOSE 1.0000 4.64E-01 2.59E-01 9.81E-01 1.59E+00 2.65E+00 3.02E+00 4.06E+00 3.28E-05 145 INGESTION OF GRAINS 1.0000 2.86E+00 6.42E-01 1.00E+01 1.09E+01 1.32E+01 1.44E+01 2.16E+01 3.27E-05 150 INGESTION OF LEAF VEG 1.0000 5.47E+00 1.15E+00 1.53E+01 2.31E+01 5.04E+01 5.30E+01 6.13E+01 6.28E-04 67 INGESTION OF ROOT CROPS 1.0000 3.89E+00 8.76E-01 1.11E+01 1.23E+01 1.58E+01 1.76E+01 2.94E+01 3.27E-05 150 INGESTION OF FRUITS 1.0000 5.91E+00 1.60E+00 2.00E+01 2.15E+01 2.55E+01 2.75E+01 4.33E+01 3.27E-05 150 INGESTION OF LEGUMES 1.0000 3.57E+00 1.07E+00 1.06E+01 1.16E+01 1.44E+01 1.58E+01 2.52E+01 3.27E-05 150 INGESTION OF BEEF 1.0000 2.97E+01 1.25E+01 7.81E+01 9.48E+01 1.09E+02 1.13E+02 1.68E+02 5.66E-06 13 INGESTION OF MILK 1.0000 1.74E+01 7.47E+00 4.76E+01 6.04E+01 8.44E+01 9.46E+01 1.31E+02 4.57E-04 113 INGESTION OF POULTRY 1.0000 8.30E+00 2.87E+00 2.08E+01 2.88E+01 5.25E+01 5.66E+01 7.35E+01 6.28E-04 67 INGESTION OF OTHER MEAT CROPS 1.0000 2.78E+00 1.30E+00 7.58E+00 1.04E+01 1.35E+01 1.50E+01 2.06E+01 8.28E-04 97 ECONOMIC COST MEASURES ($) 0-80.5 km TOTAL ECONOMIC COSTS 1.0000 6.06E+09 4.48E+09 1.14E+10 1.74E+10 3.11E+10 3.19E+10 3.64E+10 1.00E-04 101 POP.-DEPENDENT COSTS 1.0000 5.96E+09 4.38E+09 1.12E+10 1.73E+10 3.11E+10 3.19E+10 3.64E+10 1.00E-04 101 FARM-DEPENDENT COSTS 1.0000 1.00E+08 3.51E+07 3.19E+08 3.88E+08 5.35E+08 5.73E+08 7.19E+08 6.28E-04 23 POP.-DEPENDENT DECONTAMINATION COST 1.0000 1.34E+09 1.01E+09 3.10E+09 4.44E+09 7.31E+09 7.52E+09 8.50E+09 2.49E-04 4 FARM-DEPENDENT DECONTAMINATION COST 1.0000 1.95E+06 6.85E+05 5.75E+06 7.91E+06 1.07E+07 1.13E+07 1.55E+07 6.97E-05 4 POP.-DEPENDENT INTERDICTION COST 1.0000 4.41E+09 3.19E+09 9.92E+09 1.47E+10 2.13E+10 2.21E+10 2.78E+10 1.00E-04 101 FARM-DEPENDENT INTERDICTION COST 1.0000 8.49E+07 2.07E+07 3.01E+08 3.55E+08 5.08E+08 5.43E+08 6.61E+08 6.28E-04 23 POP.-DEPENDENT CONDEMNATION COST 0.9917 2.06E+08 1.29E+08 4.79E+08 6.07E+08 1.03E+09 NOT-FOUND 1.05E+09 6.64E-03 77 FARM-DEPENDENT CONDEMNATION COST 0.9917 3.77E+04 9.02E+03 8.29E+04 9.17E+04 2.03E+05 2.36E+05 2.90E+05 1.95E-03 6 EMERGENCY PHASE COST 1.0000 1.60E+06 1.33E+06 3.05E+06 3.94E+06 5.25E+06 5.43E+06 8.05E+06 5.56E-06 146 INTERMEDIATE PHASE COST 0.0000 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0
Calculation IP-CALC-09-00265, Rev. 0, Att. A.2, Page 109 12-NOV-09 13:50:14 PAGE 24 PROB QUANTILES PEAK PEAK PEAK NON-ZERO MEAN 50TH 90TH 95TH 99TH 99.5TH CONS PROB TRIAL ECONOMIC COST MEASURES ($) 0-80.5 km MILK DISPOSAL COST 1.0000 5.55E+05 3.37E+04 1.87E+06 2.56E+06 3.59E+06 3.97E+06 5.60E+06 3.40E-05 150 CROP DISPOSAL COST 1.0000 1.27E+07 8.07E+06 3.04E+07 3.31E+07 4.05E+07 4.41E+07 5.71E+07 2.28E-04 23
Calculation IP-CALC-09-00265, Rev. 0, Att. A.2, Page 110 XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX
Calculation IP-CALC-09-00265, Rev. 0, Att. A.2, Page 111 DATE AND TIME OF RUN = MACCS2 12-NOV-09 13:50:14 VERSION 1.13.1: last revised 1/8/04, K. McFadden "ATMOS" DESCRIPTION = ATMOS INPUT FOR IPEC CALCULATIONS "EARLY" DESCRIPTION = EARLY.IN, IPEC INPUT FROM THE EVACUATION TIME ESTIMATES "CHRONC" DESCRIPTION = CHRONC.IN - IPEC, "New" COMIDA2-Based Food Model SOURCE TERM 7 OF 8:
LATE LOW OVERALL RESULTS OBTAINED BY COMBINING 1 EMERGENCY RESPONSE COHORTS FROM "EARLY" WITH THE WEIGHTING FRACTIONS BELOW APPLIED TO THEM:
FRACTION OF THE PEOPLE COHORT 1 = NO EVACUATION, RELOCATION MODELS APPLY EVERYWHE 1.000 AND THEN MERGING THE 1 RESULTS ABOVE WITH THE SINGLE SET OF RESULTS FROM "CHRONC" DESCRIBED BELOW:
COHORT 2 = CHRONC.IN - IPEC, "New" COMIDA2-Based Food Model RESULTS WHICH ARE PRODUCED ONLY BY "EARLY" OR ONLY BY "CHRONC" ARE PRESENTED IN LATER SECTIONS.
12-NOV-09 13:50:14 PAGE 25 PROB QUANTILES PEAK PEAK PEAK NON-ZERO MEAN 50TH 90TH 95TH 99TH 99.5TH CONS PROB TRIAL HEALTH EFFECTS CASES CAN FAT/TOTAL 0-80.5 km 1.0000 7.23E+02 5.15E+02 1.58E+03 2.13E+03 3.17E+03 3.46E+03 4.25E+03 1.00E-03 98 CAN FAT/TOTAL 0-16.1 km 1.0000 1.03E+02 9.80E+01 1.51E+02 1.81E+02 2.10E+02 2.17E+02 2.63E+02 5.26E-05 40 POPULATION DOSE (Sv)
L-EDEWBODY TOT LIF 0-80.5 km 1.0000 1.61E+04 1.13E+04 3.65E+04 4.86E+04 7.34E+04 7.94E+04 9.52E+04 1.00E-03 98 POPULATION WEIGHTED RISK CAN FAT/TOTAL 0-16.1 km 1.0000 2.52E-04 2.32E-04 3.82E-04 4.41E-04 5.20E-04 5.35E-04 6.41E-04 5.26E-05 40
Calculation IP-CALC-09-00265, Rev. 0, Att. A.2, Page 112 DATE AND TIME OF RUN = MACCS2 12-NOV-09 13:50:14 VERSION 1.13.1: last revised 1/8/04, K. McFadden "ATMOS" DESCRIPTION = ATMOS INPUT FOR IPEC CALCULATIONS "EARLY" DESCRIPTION = EARLY.IN, IPEC INPUT FROM THE EVACUATION TIME ESTIMATES SOURCE TERM 7 OF 8:
LATE LOW RESULTS FOR A SINGLE EMERGENCY RESPONSE COHORT WITHOUT ANY WEIGHTING FRACTIONS BEING APPLIED COHORT 1 = NO EVACUATION, RELOCATION MODELS APPLY EVERYWHE 12-NOV-09 13:50:14 PAGE 26 PROB QUANTILES PEAK PEAK PEAK NON-ZERO MEAN 50TH 90TH 95TH 99TH 99.5TH CONS PROB TRIAL HEALTH EFFECTS CASES ERL FAT/TOTAL 0-80.5 km 0.0000 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0 CAN FAT/TOTAL 0-80.5 km 1.0000 7.55E+01 7.04E+01 1.42E+02 1.80E+02 2.32E+02 2.50E+02 3.13E+02 1.00E-03 98 CAN FAT/TOTAL 0-16.1 km 1.0000 2.90E+01 2.73E+01 5.22E+01 6.08E+01 7.19E+01 7.34E+01 8.80E+01 8.36E-06 145 ERL FAT/TOTAL 0-16.1 km 0.0000 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0 AVERAGE INDIVIDUAL RISK ERL FAT/TOTAL 0-0.3 km 0.0000 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0 ERL FAT/TOTAL 0.3-1.6 km 0.0000 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0 ERL FAT/TOTAL 1.6-3.2 km 0.0000 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0 POPULATION DOSE (Sv)
L-EDEWBODY TOT LIF 0-80.5 km 1.0000 1.60E+03 1.22E+03 3.06E+03 3.60E+03 5.15E+03 5.61E+03 6.86E+03 1.00E-03 98 POPULATION WEIGHTED RISK ERL FAT/TOTAL 0-3.2 km 0.0000 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0 CAN FAT/TOTAL 0-16.1 km 1.0000 7.41E-05 6.98E-05 1.23E-04 1.43E-04 2.00E-04 2.03E-04 2.25E-04 8.36E-06 145
Calculation IP-CALC-09-00265, Rev. 0, Att. A.2, Page 113 DATE AND TIME OF RUN = MACCS2 12-NOV-09 13:50:14 VERSION 1.13.1: last revised 1/8/04, K. McFadden "ATMOS" DESCRIPTION = ATMOS INPUT FOR IPEC CALCULATIONS "EARLY" DESCRIPTION = EARLY.IN, IPEC INPUT FROM THE EVACUATION TIME ESTIMATES "CHRONC" DESCRIPTION = CHRONC.IN - IPEC, "New" COMIDA2-Based Food Model SOURCE TERM 7 OF 8:
LATE LOW RESULTS FROM THE "CHRONC" MODULE ALONE COHORT 2 = CHRONC.IN - IPEC, "New" COMIDA2-Based Food Model 12-NOV-09 13:50:14 PAGE 27 PROB QUANTILES PEAK PEAK PEAK NON-ZERO MEAN 50TH 90TH 95TH 99TH 99.5TH CONS PROB TRIAL HEALTH EFFECTS CASES CAN FAT/TOTAL 0-80.5 km 1.0000 6.47E+02 4.18E+02 1.42E+03 1.97E+03 3.13E+03 3.35E+03 3.94E+03 1.00E-03 98 CAN FAT/TOTAL 0-16.1 km 1.0000 7.40E+01 7.01E+01 1.06E+02 1.11E+02 1.25E+02 1.31E+02 2.13E+02 1.73E-06 54 POPULATION DOSE (Sv)
L-EDEWBODY TOT LIF 0-80.5 km 1.0000 1.45E+04 9.48E+03 3.36E+04 4.45E+04 6.14E+04 6.84E+04 8.83E+04 1.00E-03 98 POPULATION WEIGHTED RISK CAN FAT/TOTAL 0-16.1 km 1.0000 1.78E-04 1.59E-04 3.03E-04 3.15E-04 3.44E-04 3.58E-04 5.34E-04 1.73E-06 54 L-EDEWBODY POP. DOSE (Sv) 0-80.5 km TOTAL LONG-TERM PATHWAYS DOSE 1.0000 1.45E+04 9.48E+03 3.36E+04 4.45E+04 6.14E+04 6.84E+04 8.83E+04 1.00E-03 98 LONG-TERM DIRECT EXPOSURE PATHWAYS 1.0000 1.44E+04 9.35E+03 3.36E+04 4.45E+04 6.14E+04 6.84E+04 8.83E+04 1.00E-03 98 TOTAL INGESTION PATHWAYS DOSE 1.0000 8.45E+01 3.45E+01 2.49E+02 3.12E+02 4.01E+02 4.46E+02 5.02E+02 2.40E-03 23 LONG-TERM GROUNDSHINE DOSE 1.0000 1.37E+04 8.96E+03 3.21E+04 4.33E+04 6.07E+04 6.75E+04 8.44E+04 1.00E-03 98 LONG-TERM RESUSPENSION DOSE 1.0000 6.23E+02 3.86E+02 1.40E+03 1.94E+03 2.62E+03 2.97E+03 3.86E+03 1.00E-03 98 WATER INGESTION DOSE 1.0000 1.30E+01 1.11E+01 2.27E+01 2.63E+01 3.10E+01 3.17E+01 3.91E+01 1.04E-05 146 POP.-DEPENDENT DECONTAMINATION DOSE 1.0000 8.10E+01 7.49E+01 1.32E+02 1.55E+02 2.06E+02 2.15E+02 3.17E+02 1.24E-06 147 FARM-DEPENDENT DECONTAMINATION DOSE 1.0000 3.70E-02 2.73E-02 7.75E-02 1.03E-01 2.04E-01 2.16E-01 3.65E-01 1.59E-05 146 INGESTION OF GRAINS 1.0000 2.86E+00 3.95E-01 1.03E+01 1.24E+01 1.93E+01 2.09E+01 2.46E+01 6.28E-04 23 INGESTION OF LEAF VEG 1.0000 4.79E+00 6.81E-01 1.50E+01 2.23E+01 3.53E+01 4.07E+01 6.70E+01 2.29E-05 66 INGESTION OF ROOT CROPS 1.0000 3.86E+00 5.79E-01 1.29E+01 1.85E+01 2.85E+01 3.05E+01 3.26E+01 6.28E-04 23 INGESTION OF FRUITS 1.0000 5.61E+00 8.05E-01 2.05E+01 2.72E+01 3.50E+01 3.78E+01 4.76E+01 6.28E-04 23 INGESTION OF LEGUMES 1.0000 3.40E+00 6.12E-01 1.18E+01 1.62E+01 2.21E+01 2.35E+01 2.82E+01 6.28E-04 23 INGESTION OF BEEF 1.0000 2.59E+01 6.42E+00 8.47E+01 1.02E+02 1.14E+02 1.19E+02 1.88E+02 5.46E-06 13 INGESTION OF MILK 1.0000 1.65E+01 4.77E+00 5.39E+01 7.01E+01 8.47E+01 9.20E+01 1.30E+02 7.64E-06 12 INGESTION OF POULTRY 1.0000 7.14E+00 1.98E+00 2.41E+01 3.35E+01 5.13E+01 5.43E+01 8.72E+01 2.29E-05 66 INGESTION OF OTHER MEAT CROPS 1.0000 1.50E+00 4.70E-01 4.29E+00 5.85E+00 1.00E+01 1.05E+01 1.55E+01 2.29E-05 66 ECONOMIC COST MEASURES ($) 0-80.5 km TOTAL ECONOMIC COSTS 1.0000 6.58E+08 5.97E+08 1.06E+09 1.12E+09 1.28E+09 1.36E+09 2.07E+09 2.10E-05 40 POP.-DEPENDENT COSTS 1.0000 6.43E+08 5.78E+08 1.05E+09 1.12E+09 1.28E+09 1.36E+09 2.06E+09 2.10E-05 40 FARM-DEPENDENT COSTS 1.0000 1.54E+07 4.20E+06 5.37E+07 7.42E+07 1.07E+08 1.14E+08 1.65E+08 4.16E-05 4 POP.-DEPENDENT DECONTAMINATION COST 1.0000 1.58E+08 1.35E+08 3.06E+08 3.20E+08 3.55E+08 3.72E+08 5.26E+08 2.10E-05 40 FARM-DEPENDENT DECONTAMINATION COST 1.0000 1.90E+05 8.98E+04 4.15E+05 7.38E+05 1.12E+06 1.21E+06 1.42E+06 1.11E-03 123 POP.-DEPENDENT INTERDICTION COST 1.0000 4.76E+08 4.23E+08 9.72E+08 1.03E+09 1.12E+09 1.16E+09 1.52E+09 2.10E-05 40 FARM-DEPENDENT INTERDICTION COST 1.0000 1.33E+07 2.80E+06 5.04E+07 6.78E+07 1.04E+08 1.09E+08 1.51E+08 4.16E-05 4 POP.-DEPENDENT CONDEMNATION COST 0.8144 8.73E+06 3.75E+06 1.39E+07 1.72E+07 1.03E+08 1.06E+08 1.25E+08 6.75E-05 6 FARM-DEPENDENT CONDEMNATION COST 0.8629 5.29E+03 2.47E+03 8.13E+03 9.02E+03 7.20E+04 7.48E+04 7.73E+04 2.75E-03 6 EMERGENCY PHASE COST 0.9903 1.57E+05 1.07E+05 4.01E+05 5.24E+05 9.05E+05 1.02E+06 1.10E+06 1.83E-03 144 INTERMEDIATE PHASE COST 0.0000 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0
Calculation IP-CALC-09-00265, Rev. 0, Att. A.2, Page 114 12-NOV-09 13:50:14 PAGE 28 PROB QUANTILES PEAK PEAK PEAK NON-ZERO MEAN 50TH 90TH 95TH 99TH 99.5TH CONS PROB TRIAL ECONOMIC COST MEASURES ($) 0-80.5 km MILK DISPOSAL COST 1.0000 1.25E+05 8.03E+03 4.84E+05 6.43E+05 1.29E+06 1.55E+06 2.63E+06 2.57E-04 23 CROP DISPOSAL COST 1.0000 1.80E+06 1.03E+06 5.12E+06 6.06E+06 1.00E+07 1.03E+07 1.18E+07 8.03E-05 4
Calculation IP-CALC-09-00265, Rev. 0, Att. A.2, Page 115 XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX
Calculation IP-CALC-09-00265, Rev. 0, Att. A.2, Page 116 DATE AND TIME OF RUN = MACCS2 12-NOV-09 13:50:14 VERSION 1.13.1: last revised 1/8/04, K. McFadden "ATMOS" DESCRIPTION = ATMOS INPUT FOR IPEC CALCULATIONS "EARLY" DESCRIPTION = EARLY.IN, IPEC INPUT FROM THE EVACUATION TIME ESTIMATES "CHRONC" DESCRIPTION = CHRONC.IN - IPEC, "New" COMIDA2-Based Food Model SOURCE TERM 8 OF 8:
LATE LOWLOW OVERALL RESULTS OBTAINED BY COMBINING 1 EMERGENCY RESPONSE COHORTS FROM "EARLY" WITH THE WEIGHTING FRACTIONS BELOW APPLIED TO THEM:
FRACTION OF THE PEOPLE COHORT 1 = NO EVACUATION, RELOCATION MODELS APPLY EVERYWHE 1.000 AND THEN MERGING THE 1 RESULTS ABOVE WITH THE SINGLE SET OF RESULTS FROM "CHRONC" DESCRIBED BELOW:
COHORT 2 = CHRONC.IN - IPEC, "New" COMIDA2-Based Food Model RESULTS WHICH ARE PRODUCED ONLY BY "EARLY" OR ONLY BY "CHRONC" ARE PRESENTED IN LATER SECTIONS.
12-NOV-09 13:50:14 PAGE 29 PROB QUANTILES PEAK PEAK PEAK NON-ZERO MEAN 50TH 90TH 95TH 99TH 99.5TH CONS PROB TRIAL HEALTH EFFECTS CASES CAN FAT/TOTAL 0-80.5 km 1.0000 6.15E+02 4.08E+02 1.32E+03 1.79E+03 2.54E+03 2.87E+03 3.60E+03 1.00E-03 98 CAN FAT/TOTAL 0-16.1 km 1.0000 9.10E+01 8.52E+01 1.29E+02 1.46E+02 1.96E+02 2.03E+02 2.43E+02 1.73E-06 54 POPULATION DOSE (Sv)
L-EDEWBODY TOT LIF 0-80.5 km 1.0000 1.38E+04 1.00E+04 3.19E+04 4.19E+04 5.99E+04 6.67E+04 8.08E+04 1.00E-03 98 POPULATION WEIGHTED RISK CAN FAT/TOTAL 0-16.1 km 1.0000 2.24E-04 2.10E-04 3.45E-04 3.85E-04 4.99E-04 5.08E-04 6.15E-04 1.73E-06 54
Calculation IP-CALC-09-00265, Rev. 0, Att. A.2, Page 117 DATE AND TIME OF RUN = MACCS2 12-NOV-09 13:50:14 VERSION 1.13.1: last revised 1/8/04, K. McFadden "ATMOS" DESCRIPTION = ATMOS INPUT FOR IPEC CALCULATIONS "EARLY" DESCRIPTION = EARLY.IN, IPEC INPUT FROM THE EVACUATION TIME ESTIMATES SOURCE TERM 8 OF 8:
LATE LOWLOW RESULTS FOR A SINGLE EMERGENCY RESPONSE COHORT WITHOUT ANY WEIGHTING FRACTIONS BEING APPLIED COHORT 1 = NO EVACUATION, RELOCATION MODELS APPLY EVERYWHE 12-NOV-09 13:50:14 PAGE 30 PROB QUANTILES PEAK PEAK PEAK NON-ZERO MEAN 50TH 90TH 95TH 99TH 99.5TH CONS PROB TRIAL HEALTH EFFECTS CASES ERL FAT/TOTAL 0-80.5 km 0.0000 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0 CAN FAT/TOTAL 0-80.5 km 1.0000 4.98E+01 4.41E+01 9.83E+01 1.10E+02 1.41E+02 1.57E+02 2.06E+02 1.00E-03 98 CAN FAT/TOTAL 0-16.1 km 1.0000 1.89E+01 1.63E+01 3.31E+01 3.77E+01 5.01E+01 5.08E+01 5.97E+01 1.24E-06 147 ERL FAT/TOTAL 0-16.1 km 0.0000 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0 AVERAGE INDIVIDUAL RISK ERL FAT/TOTAL 0-0.3 km 0.0000 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0 ERL FAT/TOTAL 0.3-1.6 km 0.0000 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0 ERL FAT/TOTAL 1.6-3.2 km 0.0000 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0 POPULATION DOSE (Sv)
L-EDEWBODY TOT LIF 0-80.5 km 1.0000 1.10E+03 1.01E+03 2.09E+03 2.60E+03 3.47E+03 3.79E+03 4.64E+03 1.00E-03 98 POPULATION WEIGHTED RISK ERL FAT/TOTAL 0-3.2 km 0.0000 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0 CAN FAT/TOTAL 0-16.1 km 1.0000 4.83E-05 4.37E-05 9.11E-05 1.02E-04 1.08E-04 1.11E-04 1.53E-04 1.24E-06 147
Calculation IP-CALC-09-00265, Rev. 0, Att. A.2, Page 118 DATE AND TIME OF RUN = MACCS2 12-NOV-09 13:50:14 VERSION 1.13.1: last revised 1/8/04, K. McFadden "ATMOS" DESCRIPTION = ATMOS INPUT FOR IPEC CALCULATIONS "EARLY" DESCRIPTION = EARLY.IN, IPEC INPUT FROM THE EVACUATION TIME ESTIMATES "CHRONC" DESCRIPTION = CHRONC.IN - IPEC, "New" COMIDA2-Based Food Model SOURCE TERM 8 OF 8:
LATE LOWLOW RESULTS FROM THE "CHRONC" MODULE ALONE COHORT 2 = CHRONC.IN - IPEC, "New" COMIDA2-Based Food Model 12-NOV-09 13:50:14 PAGE 31 PROB QUANTILES PEAK PEAK PEAK NON-ZERO MEAN 50TH 90TH 95TH 99TH 99.5TH CONS PROB TRIAL HEALTH EFFECTS CASES CAN FAT/TOTAL 0-80.5 km 1.0000 5.65E+02 3.61E+02 1.26E+03 1.72E+03 2.51E+03 2.84E+03 3.39E+03 1.00E-03 98 CAN FAT/TOTAL 0-16.1 km 1.0000 7.22E+01 6.69E+01 1.06E+02 1.11E+02 1.25E+02 1.31E+02 2.24E+02 1.73E-06 54 POPULATION DOSE (Sv)
L-EDEWBODY TOT LIF 0-80.5 km 1.0000 1.27E+04 8.44E+03 3.02E+04 4.07E+04 5.98E+04 6.66E+04 7.61E+04 1.00E-03 98 POPULATION WEIGHTED RISK CAN FAT/TOTAL 0-16.1 km 1.0000 1.76E-04 1.57E-04 2.90E-04 3.10E-04 3.41E-04 3.55E-04 5.67E-04 1.73E-06 54 L-EDEWBODY POP. DOSE (Sv) 0-80.5 km TOTAL LONG-TERM PATHWAYS DOSE 1.0000 1.27E+04 8.44E+03 3.02E+04 4.07E+04 5.98E+04 6.66E+04 7.61E+04 1.00E-03 98 LONG-TERM DIRECT EXPOSURE PATHWAYS 1.0000 1.25E+04 8.36E+03 3.02E+04 4.07E+04 5.98E+04 6.66E+04 7.61E+04 1.00E-03 98 TOTAL INGESTION PATHWAYS DOSE 1.0000 8.15E+01 3.18E+01 2.27E+02 3.09E+02 4.73E+02 5.15E+02 5.82E+02 6.28E-04 23 LONG-TERM GROUNDSHINE DOSE 1.0000 1.22E+04 8.20E+03 2.99E+04 3.92E+04 5.87E+04 6.59E+04 7.40E+04 1.00E-03 98 LONG-TERM RESUSPENSION DOSE 1.0000 3.44E+02 2.29E+02 7.84E+02 1.00E+03 1.52E+03 1.82E+03 2.11E+03 1.00E-03 98 WATER INGESTION DOSE 1.0000 1.08E+01 9.53E+00 1.97E+01 2.21E+01 2.83E+01 3.01E+01 3.28E+01 1.04E-05 146 POP.-DEPENDENT DECONTAMINATION DOSE 1.0000 6.40E+01 5.91E+01 1.17E+02 1.38E+02 2.00E+02 2.04E+02 2.50E+02 1.24E-06 147 FARM-DEPENDENT DECONTAMINATION DOSE 1.0000 2.86E-02 2.21E-02 5.87E-02 7.40E-02 1.34E-01 1.87E-01 2.55E-01 1.59E-05 146 INGESTION OF GRAINS 1.0000 2.83E+00 4.00E-01 9.62E+00 1.25E+01 2.05E+01 2.19E+01 2.64E+01 6.28E-04 23 INGESTION OF LEAF VEG 1.0000 4.73E+00 6.38E-01 1.56E+01 2.22E+01 3.27E+01 3.66E+01 7.03E+01 2.85E-05 75 INGESTION OF ROOT CROPS 1.0000 3.77E+00 5.64E-01 1.24E+01 1.81E+01 2.85E+01 3.08E+01 3.47E+01 6.28E-04 23 INGESTION OF FRUITS 1.0000 5.54E+00 8.04E-01 1.79E+01 2.68E+01 3.95E+01 4.53E+01 5.10E+01 6.28E-04 23 INGESTION OF LEGUMES 1.0000 3.26E+00 5.23E-01 1.10E+01 1.51E+01 2.22E+01 2.39E+01 2.97E+01 6.28E-04 23 INGESTION OF BEEF 1.0000 2.54E+01 6.43E+00 8.06E+01 1.07E+02 1.53E+02 1.79E+02 2.08E+02 6.28E-04 23 INGESTION OF MILK 1.0000 1.64E+01 4.59E+00 5.25E+01 6.69E+01 1.01E+02 1.05E+02 1.46E+02 5.46E-06 13 INGESTION OF POULTRY 1.0000 7.35E+00 1.91E+00 2.55E+01 3.42E+01 5.09E+01 5.54E+01 9.64E+01 2.85E-05 75 INGESTION OF OTHER MEAT CROPS 1.0000 1.41E+00 4.56E-01 4.46E+00 5.79E+00 7.75E+00 8.38E+00 1.60E+01 2.85E-05 75 ECONOMIC COST MEASURES ($) 0-80.5 km TOTAL ECONOMIC COSTS 1.0000 5.62E+08 5.20E+08 1.02E+09 1.07E+09 1.18E+09 1.23E+09 1.75E+09 2.10E-05 40 POP.-DEPENDENT COSTS 1.0000 5.51E+08 4.91E+08 1.02E+09 1.06E+09 1.18E+09 1.23E+09 1.74E+09 2.10E-05 40 FARM-DEPENDENT COSTS 1.0000 1.15E+07 3.18E+06 3.59E+07 5.42E+07 9.60E+07 1.05E+08 1.49E+08 6.29E-05 5 POP.-DEPENDENT DECONTAMINATION COST 1.0000 1.36E+08 1.19E+08 2.61E+08 3.05E+08 3.32E+08 3.45E+08 4.37E+08 6.26E-05 26 FARM-DEPENDENT DECONTAMINATION COST 1.0000 1.61E+05 8.03E+04 3.69E+05 6.35E+05 1.04E+06 1.11E+06 1.25E+06 1.13E-03 26 POP.-DEPENDENT INTERDICTION COST 1.0000 4.09E+08 3.64E+08 7.64E+08 8.79E+08 1.04E+09 1.07E+09 1.31E+09 2.10E-05 85 FARM-DEPENDENT INTERDICTION COST 1.0000 1.00E+07 1.94E+06 3.48E+07 5.24E+07 8.07E+07 1.02E+08 1.37E+08 6.29E-05 5 POP.-DEPENDENT CONDEMNATION COST 0.8040 5.25E+06 3.43E+06 1.10E+07 1.20E+07 1.46E+07 1.59E+07 1.25E+08 1.64E-05 6 FARM-DEPENDENT CONDEMNATION COST 0.7189 1.98E+03 2.03E+03 2.74E+03 7.70E+03 NOT-FOUND NOT-FOUND 8.49E+03 4.80E-02 1 EMERGENCY PHASE COST 0.9902 7.16E+04 1.51E+04 1.95E+05 3.17E+05 3.95E+05 4.34E+05 4.97E+05 1.83E-03 20 INTERMEDIATE PHASE COST 0.0000 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0
Calculation IP-CALC-09-00265, Rev. 0, Att. A.2, Page 119 12-NOV-09 13:50:14 PAGE 32 PROB QUANTILES PEAK PEAK PEAK NON-ZERO MEAN 50TH 90TH 95TH 99TH 99.5TH CONS PROB TRIAL ECONOMIC COST MEASURES ($) 0-80.5 km MILK DISPOSAL COST 1.0000 9.39E+04 5.58E+03 3.52E+05 5.31E+05 1.13E+06 1.30E+06 2.26E+06 6.28E-04 137 CROP DISPOSAL COST 1.0000 1.25E+06 6.64E+05 3.17E+06 4.08E+06 5.88E+06 6.55E+06 1.18E+07 3.87E-05 62 Successful completion of MACCS2 was achieved!
This job required a total of 25.750 CPU seconds Input processing required 0.227 CPU seconds Simulation required 24.961 CPU seconds Output processing required 0.562 CPU seconds