ML122750393

From kanterella
Jump to navigation Jump to search

NRC Comments on Draft Licensee-Developed Exam (Written) (Folder 2)
ML122750393
Person / Time
Site: FitzPatrick 
(DPR-059)
Issue date: 07/26/2012
From: Garchow S
Operations Branch I
To: Laing D
Entergy Nuclear Northeast
Jackson D
Shared Package
ML120270122 List:
References
TAC U01843
Download: ML122750393 (7)


Text

ES-401 [[::JAF-2012-09|JAF-2012-09]] Written Examination Review Worksheet Form ES-401-9 Instructions

[Refer to Section D of ES-401 and Appendix B for additional information regarding each of the following concepts.]

1. Enter the level of knowledge (LOK) of each question as either (F)undamental or (H)igher cognitive level.
2. Enter the level of difficulty (LOD) of each question using a 1 B 5 (easy B difficult) rating scale (questions in the 2 B 4 range are acceptable).
3. Check the appropriate box if a psychometric flaw is identified:

The stem lacks sufficient focus to elicit the correct answer (e.g., unclear intent, more information is needed, or too much needless information).

The stem or distractors contain cues (i.e., clues, specific determiners, phrasing, length, etc).

The answer choices are a collection of unrelated true/false statements.

The distractors are not credible; single implausible distractors should be repaired, more than one is unacceptable.

One or more distractors is (are) partially correct (e.g., if the applicant can make unstated assumptions that are not contradicted by stem).

4. Check the appropriate box if a job content error is identified:

The question is not linked to the job requirements (i.e., the question has a valid K/A but, as written, is not operational in content).

The question requires the recall of knowledge that is too specific for the closed reference test mode (i.e., it is not required to be known from memory).

The question contains data with an unrealistic level of accuracy or inconsistent units (e.g., panel meter in percent with question in gallons).

The question requires reverse logic or application compared to the job requirements.

5. Check questions that are sampled for conformance with the approved K/A and those that are designated SRO-only (K/A and license level mismatches are unacceptable).
6. Enter question source: (B)ank, (M)odified, or (N)ew. Check that (M)odified questions meet criteria of ES-401 Section D.2.f.
7. Based on the reviewer=s judgment, is the question as written (U)nsatisfactory (requiring repair or replacement), in need of (E)ditorial enhancement, or (S)atisfactory?
8. At a minimum, explain any AU@ ratings (e.g., how the Appendix B psychometric attributes are not being met).

Page 1 of 7 OBDI 202 - IOLE Process Q#

1.

LOK (F/H)

2.

LOD (1-5)

3. Psychometric Flaws
4. Job Content Flaws
5. Other
6.

B/M/N

7.

U/E/S

8.

Explanation Stem Focus Cues T/F Cred.

Dist.

Partial Job-Link Minutia

  1. /

units Back-ward Q=

K/A SRO Only 1

F 2

N S

C, CR, 41.10 2

H 4

N S

A, CR, 41.2 3

F 3

N S

C, CR, 41.7 4

H 2

N S

B, CR, 41.4 5

F 3

N S

C, CR, 41.7 6

F 2

N S

B, CR, 41.7 7

F 2

N S

D, CR, 41.4 8

H 3

N S

D, CR, 41.4 9

F 2

N S

D, CR, 41.10 10 H

3 N

S B, CR, 41.11

ES-401 [[::JAF-2012-09|JAF-2012-09]] 2

Form ES-401-9 Page 2 of 7 OBDI 202 - IOLE Process Q#

1.

LOK (F/H)

2.

LOD (1-5)

3. Psychometric Flaws
4. Job Content Flaws
5. Other
6.

B/M/N

7.

U/E/S

8.

Explanation Stem Focus Cues T/F Cred.

Dist.

Partial Job-Link Minutia

  1. /

units Back-ward Q=

K/A SRO Only 11 H

3 N

E S

D, OR, 41.10 - Change the stem to read Based on the conditions, why is drywell sprays not allowed? Also, eliminate the yes/no from the distractors.

After discussing the with the exam author, this question will be left as originally drafted.

12 F

2 N

S B, CR, 41.7 13 F

3 N

S A, CR, 41.5 14 F

3 M

S B, OR, 41.10 15 F

3 N

E S

A, CR, 41.5 - Change the stem to read, The reason EOP-4 (Primary Containment Control) directs HPCI to be tripped if torus level cannot be maintained greater than 10.75 feet is to prevent:

Change was be made as suggested.

16 H

4 N

S B, CR, 41.7 17 H

3 N

S C, CR, 41.10 18 F

2 N

S D, CR, 41.11 19 F

3 N

S A, CR, 41.8 20 F

4 N

S B, CR, 41.10 21 H

3 N

E A, CR, 41.10 - Change distractor A to read, due to the imminent loss of the main condenser.

Revised the question as suggested.

22 F

3 N

S D, CR, 41.5 23 H

3 N

S C, CR, 41.6 24 H

3 N

E S

A, CR, 41.9 - The way the stem reads, it sounds like a Div II isolation occurred. This would make one half of the MSIVs to close. Will discuss with author.

Will clarify the stem.

Stem was clarified 25 F

2 N

S A, CR, 41.3 26 H

2 N

S B, CR, 41.7 27 F

4 N

S D, CR, 41.7 28 H

4 N

S C, CR, 41.7

ES-401 [[::JAF-2012-09|JAF-2012-09]] 3

Form ES-401-9 Page 3 of 7 OBDI 202 - IOLE Process Q#

1.

LOK (F/H)

2.

LOD (1-5)

3. Psychometric Flaws
4. Job Content Flaws
5. Other
6.

B/M/N

7.

U/E/S

8.

Explanation Stem Focus Cues T/F Cred.

Dist.

Partial Job-Link Minutia

  1. /

units Back-ward Q=

K/A SRO Only 29 F

3 N

S C, CR, 41.8 30 H

2 N

S B, CR, 41.5 31 F

2 N

S A, CR, 41.7 32 F

3 N

S C, CR, 41.7 33 F

2 N

S D, CR, 41.6 34 H

3 N

S B, CR, 41.7 35 H

3 N

S B, CR, 41.6 36 H

3 N

S C, CR, 41.7 37 F

2 N

S B, CR, 41.6 38 H

3 N

S B, CR, 41.2 39 F

3 N

S A, CR, 41.6 40 F

2 N

S D, CR, 41.6 41 H

4 N

S D, CR, 41.7 42 F

3 N

S A, CR, 41.10 43 F

3 N

S D, CR, 41.9 44 H

3 U

N U

S D, CR, 41.3 - Distractors A and B are not credible.

Will revise the distractors.

The distractors were revised.

45 F

3 N

S C, CR, 41.4 46 F

3 N

S C, CR, 41.7 47 H

2 U

N U

S B, CR, 41.7 - Distractors A and C are not credible.

This question will be revised.

The question was revised.

48 H

3 N

S C, OR, 41.10 49 F

4 N

S B, CR, 41.4 50 H

2 N

S D, CR, 41.4

ES-401 [[::JAF-2012-09|JAF-2012-09]] 4

Form ES-401-9 Page 4 of 7 OBDI 202 - IOLE Process Q#

1.

LOK (F/H)

2.

LOD (1-5)

3. Psychometric Flaws
4. Job Content Flaws
5. Other
6.

B/M/N

7.

U/E/S

8.

Explanation Stem Focus Cues T/F Cred.

Dist.

Partial Job-Link Minutia

  1. /

units Back-ward Q=

K/A SRO Only 51 H

2 N

S C, CR, 41.7 52 F

2 E

N E

S D, CR, 41.4 - Delete the conditions in the stem with the exception of the fill in the blank sentence at the end as the initial conditions are irrelevant to the question.

This question will be revised as recommended.

The question was revised.

53 H

3 U

N U

S B, CR, 41.4 - This question is a KA mismatch because it does not address the effect the malfunction will have on CCW.

This question will be revised to focus on RBCW (called CCWS in the KA catalogue).

The question was rewritten.

54 H

3 N

S A, CR, 41.4 55 F

2 N

S A, CR, 41.6 56 H

2 N

S C, CR, 41.6 57 F

3 N

S D, CR, 41.9 58 F

3 N

S C, CR, 41.6 59 H

3 N

S C, CR, 41.7 60 H

3 N

S D, CR, 41.7 61 H

3 N

S C, CR, 41.5 62 F

3 N

S A, CR, 41.4 63 H

3 N

S A, CR, 41.11 64 F

4 N

S D, CR, 41.11 65 F

3 N

S B, CR, 41.5 66 F

3 N

S D, CR, 41.10 67 F

2 N

S D, CR, 41.10 68 H

3 N

S C, CR, 41.10 69 F

2 N

S B, CR, 41.10 70 H

2 N

S B, CR, 41.10 71 F

2 N

S A, CR, 41.10

ES-401 [[::JAF-2012-09|JAF-2012-09]] 5

Form ES-401-9 Page 5 of 7 OBDI 202 - IOLE Process Q#

1.

LOK (F/H)

2.

LOD (1-5)

3. Psychometric Flaws
4. Job Content Flaws
5. Other
6.

B/M/N

7.

U/E/S

8.

Explanation Stem Focus Cues T/F Cred.

Dist.

Partial Job-Link Minutia

  1. /

units Back-ward Q=

K/A SRO Only 72 F

3 N

S B, CR, 41.12 73 F

3 N

S D, CR, 41.11 74 F

3 U

U S

B, CR, 43.10 - This is a KA mismatch because it is not generic on how to verify an alarm setpoint.

Will revise the question to match the KA.

The question was revised.

75 F

2 N

S B, CR, 41.10 76 There is no SRO exam.

77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94

ES-401 [[::JAF-2012-09|JAF-2012-09]] 6

Form ES-401-9 Page 6 of 7 OBDI 202 - IOLE Process Q#

1.

LOK (F/H)

2.

LOD (1-5)

3. Psychometric Flaws
4. Job Content Flaws
5. Other
6.

B/M/N

7.

U/E/S

8.

Explanation Stem Focus Cues T/F Cred.

Dist.

Partial Job-Link Minutia

  1. /

units Back-ward Q=

K/A SRO Only 95 96 97 98 99 100 RO TOTALS:

B= 2 (3%)

F= 43 (57%)

E= 4 Additional Notes:

M= 0 H= 32 (43%)

U= 4 N= 73 (97%)

SRO TOTALS:

B=

F=

E=

Additional Notes:

M=

H=

U=

N=

GENERAL COMMENT

S:

1. Bank questions are indicated by B; Modified are indicated by M; New questions are indicated by N
2.

Chief Examiner follow-up comments are indicated in blue.

3.

Average difficulty is _2.7_ on the RO exam and na___ on the SRO exam. These values fall within the expected range for this reviewer

4.

The 10CFR55.41/43 distribution is: RO / SRO 41.1 = 0 43.1 =

41.2 = 3 43.2 =

41.3 = 2 43.3 =

41.4 = 10 43.4 =

41.5 = 6 43.5 =

41.6 = 9 43.6 =

41.7 = 18 43.7 =

41.8 = 2 41.9 = 3 41.10 = 17 41.11 = 5

ES-401 [[::JAF-2012-09|JAF-2012-09]] 7

Form ES-401-9 Page 7 of 7 OBDI 202 - IOLE Process 41.12 = 2 41.13 = 0 41.14 = 0

5.

The answer distribution is:

A = 15 (20%)

/

B = 29 (39%)

/

C = 18 (24%)

/

D = 13 (17%)

/

6.

There are 3 questions with attachments provided.

7.

The distribution of correct answers for distractor B is high. Will have the author revise the distribution.

7.

This exam was reviewed by S. Garchow on July 23-24, 2012.