1 NRR-PMDAPEm Resource From:

Thompson, Jon Sent:

Thursday, August 23, 2012 10:48 AM To:

Ashe, Ken Cc:

Sheng, Simon

Subject:

Request for Additional Information for License Amendment Request dated March 5, 2012 (TAC Nos. ME8213 and ME8214), RAI Questions 45 and 46

SUBJECT:

MCGUIRE NUCLEAR STATION, UNITS 1 AND 2, REQUEST FOR ADDITIONAL INFORMATION, QUESTIONS 45 AND 46 REGARDING LICENSE AMENDMENT RELATED TO MEASUREMENT UNCERTAINTY RECAPTURE POWER UPRATE (TAC NOS. ME8213 AND ME8214)

By letter dated March 5, 2012, Duke Energy Carolinas, LLC (the licensee), submitted a proposed license amendment to change the McGuire Nuclear Station, Units 1 and 2 (McGuire 1 and 2), Technical Specifications (TSs). The proposed change revises the TSs to implement a measurement uncertainty recapture power uprate for McGuire 1 and 2.

The U.S. Nuclear Regulatory Commission (NRC) staff has reviewed the licensees submittal and determined that additional information is needed in order to complete our review. The enclosed document describes this request for additional information (RAI). Please note that the numbering of the questions in this RAI does not begin at the number one. Six prior RAIs regarding this proposed license amendment were issued to you by letters dated April 27, 2012 (Agencywide Documents Access and Management System (ADAMS) Accession No. ML12117A175), May 22, 2012 (ADAMS Accession No. ML12138A267), June 6, 2012, (ADAMS Accession No. ML12158A481), June 15, 2012 (ADAMS Accession No. ML12168A002), August 1, 2012 (ADAMS Accession No. ML12215A330), and August 6, 2012 (ADAMS Accession No. ML12219A271) with RAI questions numbered 1-4, 5-19, 20-31, 32-40, 41-42, and 43-44, respectively.

A telephone conference will be set up to discuss these RAI questions, if needed. If you have any questions, please call me at 301-415-1119.

Sincerely, Jon Thompson, Project Manager Plant Licensing Branch II-1 Division of Operating Reactor Licensing Office of Nuclear Reactor Regulation Docket Nos. 50-369 and 50-370

Enclosure:

RAI REQUEST FOR ADDITIONAL INFORMATION BY THE OFFICE OF NUCLEAR REACTOR REGULATION REGARDING LICENSE AMENDMENT REQUEST RELATED TO THE IMPLEMENTATION OF A MEASUREMENT UNCERTAINTY RECAPTURE POWER UPRATE

2 MCGUIRE NUCLEAR STATION, UNITS 1 AND 2 By letter dated March 5, 2012 (Agencywide Documents Access and Management System (ADAMS),

Accession No. ML12082A210), as supplemented, Duke Energy Carolinas, LLC (Duke Energy, the licensee),

submitted a license amendment request (LAR) to change the McGuire Nuclear Station, Units 1 and 2 (McGuire 1 and 2), Technical Specifications (TSs). The proposed change revises the TSs to implement a measurement uncertainty recapture (MUR) power uprate for McGuire 1 and 2.

The NRC staff has reviewed the licensees response and determined that following additional information are needed to complete the safety evaluation:

45. Please provide the current operating EFPYs for McGuire 1 and 2 to assist in determining the margin available in the current Pressure-Temperature limits for 34 EFPY.
46. Please confirm that the ISI records for McGuire 1 and 2 show no Reactor Vessel (RV) surface flaws. If any RV surface flaws were detected, please characterize them.

Hearing Identifier:

NRR_PMDA Email Number:

458 Mail Envelope Properties (Jon.Thompson@nrc.gov20120823104800)

Subject:

Request for Additional Information for License Amendment Request dated March 5, 2012 (TAC Nos. ME8213 and ME8214), RAI Questions 45 and 46 Sent Date:

8/23/2012 10:48:07 AM Received Date:

8/23/2012 10:48:00 AM From:

Thompson, Jon Created By:

Jon.Thompson@nrc.gov Recipients:

"Sheng, Simon" <Simon.Sheng@nrc.gov>

Tracking Status: None "Ashe, Ken" <Ken.Ashe@duke-energy.com>

Tracking Status: None Post Office:

Files Size Date & Time MESSAGE 3236 8/23/2012 10:48:00 AM Options Priority:

Standard Return Notification:

No Reply Requested:

No Sensitivity:

Normal Expiration Date:

Recipients Received: