ULNRC-05883, Request to Correct Typographical Error Identified in Technical Specification 3.1.9 Required Action A.3

From kanterella
(Redirected from ML12194A683)
Jump to navigation Jump to search

Request to Correct Typographical Error Identified in Technical Specification 3.1.9 Required Action A.3
ML12194A683
Person / Time
Site: Callaway Ameren icon.png
Issue date: 07/12/2012
From: Maglio S
Ameren Missouri, Union Electric Co
To:
Document Control Desk, Office of Nuclear Reactor Regulation
References
ULNRC-05883
Download: ML12194A683 (5)


Text

~'t WAmeren Callaway Plant MISSOURI July 12, 2012 ULNRC-05883 U.S. Nuclear Regulatory Commission Attn: Document Control Desk Washington, DC 20555-0001 Ladies and Gentlemen:

DOCKET NUMBER 50-483 CALLAWAY PLANT UNIT 1 UNION ELECTRIC CO.

FACILITY OPERATING LICENSE NPF-30 REQUEST TO CORRECT TYPOGRAPHICAL ERROR IDENTIFIED IN TECHNICAL SPECIFICATION 3.1.9 REQUIRED ACTION A.3 The purpose of this letter is to request action for correction of a typographical error identified in Technical Specification (TS) 3.1.9, "RCS Boron Limitations< 500°F," ofthe Callaway Technical Specifications. The error is that the"?:" symbol is incorrectly displayed as "S" in front ofthe value for the reactor coolant system (RCS) cold leg temperature limit specified in Required Action A.3. As explained below, the error occurred in connection with the issuance of Amendment 202 to the Callaway Operating License TS 3 .1. 9 was added to the Technical Specifications via License Amendment 174 which was issued and implemented in 2006. As intended, the "?:" symbol was present in Required Action A.3 at that time.

No subsequent TS changes were made such that they would have directly affected TS 3.1.9 until the processing and issuance of Amendment 202. In that regard, it was recently determined that the "?:"

symbol was inadvertently changed from a symbol character to a text character with the issuance of Amendment 202 in July 2011. Amendment 202 extensively revised the Technical Specifications by relocating specific surveillance frequencies to a licensee controlled program such that a significant amount of text was inserted into and removed from many TS sections. Due to the text changes, the amendment required issuing additional revised TS pages due to re-pagination.

In the software used for the Callaway Technical Specifications, Character Tags are used to change the look of text and to ensure that the documents are formatted consistently. ForTS pages that are incorporated into the amendment because of re-pagination, the existing revision bar Character Tags are removed and a new revision bar is added to the footer to show that the change to the page is due to page re-numbering. It appears that during Amendment 202, the symbol Character Tag for Required Action A.3 was inadvertently removed with the removal of the revision Character Tags on this page.

                                                                                                                                                                                                                                                • PO Box 620 Fulton, MD 65251 AmerenMissouri.com

ULNRC-05883 July 12, 2012 Page 2 Due to the volume of pages required to be issued for Amendment 202, this error was not identified in the review that was conducted prior to transmitting the clean typed pages to the NRC for issuance of the amendment.

In order to correct the problem of the missing"~" in Required Action A.3, Ameren Missouri is hereby providing (in the enclosure to this letter) a corrected, clean copy ofpage 3.1-22 (with Amendment No.

202 indicated on the page) for use in re-issuance of the corrected page. This will enable the NRC to re-issue a corrected TS page 3.1-22 for License Amendment 202, reflecting the corrected symbol in front of the value for the RCS cold leg temperature specified in Required Action A.3.

It should be noted that a review of the Amendment 202 issued pages and of the current Technical Specifications did not identify any additional issues with symbol Character Tags in the TS documents.

This letter contains no new commitments. Please contact Tom Elwood, Supervising Engineer, Regulatory Affairs and Licensing at 314-225-1905 for any questions you may have regarding this submittal.

Sincerely,

.<J~t{A M2 Scott A. Maglio Regulatory Affai Manager Enclosure

ULNRC-05883 July 12, 2012 Page 3 cc: Mr. Elmo E. Collins Regional Administrator U.S. Nuclear Regulatory Commission Region IV 1600 East Lamar Boulevard Arlington, TX 76011-4511 Senior Resident Inspector Callaway Resident Office U.S. Nuclear Regulatory Commission 8201 NRC Road Steedman, MO 65077 Mr. Andrew Hon Senior Project Manager, Callaway Plant Office ofNuclear Reactor Regulation U.S. Nuclear Regulatory Commission Mail Stop 0-8G 14 Washington, DC 20555-2738

ULNRC-05883 July 12, 2012 Page4 Index and send hardcopy to QA File A160.0761 Hardcopy:

Certrec Corporation 4150 International Plaza Suite 820 Fort Worth, TX 76109 (Certrec receives ALL attachments as long as they are non-safeguards and may be publicly disclosed.)

Electronic distribution for the following can be made via Responses and Reports ULNRC Distribution:

A. C. Heflin F. M. Diya C. 0. Reasoner III L. H. Graessle S.M. Maglio T. B. Elwood R. Holmes-Bobo NSRB Secretary Mr. Bill Muilenburg (WCNOC)

Mr. Tim Hope (Luminant Power)

Mr. Ron Barnes (APS)

Mr. Tom Baldwin (PG&E)

Mr. Mike Murray (STPNOC)

Ms. Linda Conklin (SCE)

Mr. John O'Neill (Pillsbury Winthrop Shaw Pittman LLP)

RCS Boron Limitations< 500°F 3.1.9 3.1 REACTIVITY CONTROL SYSTEMS 3.1.9 RCS Boron Limitations < 500 oF LCO 3.1.9 The boron concentration of the Reactor Coolant System (RCS) shall be greater than the all rods out (ARO) critical boron concentration.

APPLICABILITY: MODE 2 with keff < 1.0 with any RCS cold leg temperature < 500°F and with Rod Control System capable of rod withdrawal, MODE 3 with any RCS cold leg temperature < 500°F and with Rod Control System capable of rod withdrawal, MODES 4 and 5 with Rod Control System capable of rod withdrawal.

ACTIONS COMPLETION CONDITION REQUIRED ACTION TIME A RCS boron concentration A.1 Initiate boration to Immediately not within limit. restore RCS boron concentration to within limit.

OR A.2 Initiate action to place Immediately the Rod Control System in a condition incapable of rod withdrawal.

OR A.3 ------------ NOTE -----------

Not applicable in MODES 4 and 5.

Initiate action to increase Immediately all RCS cold leg temperatures to ~ 500°F.

CALLAWAY PLANT 3.1-22 Amendment No. 202 Corrected