Plum Brook Reactor Facility FSSR, Attachment 12 Appendix B Rev. 0, Page 94 of 150 Survey Unit RB-3-30 RB -15' - RB -15' Ceiling Section #7
~.
s @0 1- -F 00 qT
-- Ism RB-3-30 AREA: RB -15' Elevation, Ceiling Section #7 Measurement Locations and results Location I X Co-ord (m)
Y Co-ord (m) dpm/1 00-cm2 Type Notes 3.3 0.6 SM-1 431 Systematic N/A 1.4 0.2 SM-2 667 Systematic N/A 4.8 0.2 SM-3 516 Systematic N/A 3.1 3.2 SM-4 458 Systematic N/A 6.3 0.2 SM-5 150 Systematic N/A 3.5 Edge SM-6
-248 Systematic N/A 6.1 0.15 SM-7
-124 Systematic N/A 3.3 0.4 SM-8
-52 Systematic N/A 3.3 Edge SM-9 203 Systematic N/A 3.0 Edge SM-10
-20 Systematic N/A 1.5 0.4 SM-11
-281 Systematic N/A
- Sample points SM-1 through SM-4 are measured from the nearest beam to the West and to the South of the sample point. The X-Y coordinates for SM-5 through SM-1 1 are measured from the lower left corner of the beam surface on which they lie.
Plum Brook Reactor Facility FSSR, Attachment 12 Appendix B Rev. 0, Page 95 of 150 Survey Unit RB-3-31 RB -15' - RB -15' Ceiling Section #8 E
SM SM4I RB-3-31 AREA: RB -15' Elevation, Ceiling Section #8 Measurement Locations and results Location I X Co-ord (m)
Y Co-ord (m) dpml100-cm2 Type Notes 2.1 Edge SM-1 340 Systematic N/A 0.1 2.1 SM-2
-52 Systematic N/A 1.8 2.1 SM-3 346 Systematic N/A 1.8 0.2 SM-4 353 Systematic N/A 5.3 0.2 SM-5 627 Systematic N/A 0.1 3.2 SM-6 0
Systematic N/A 3.6 3.2 SM-7 320 Systematic N/A 1.1 Edge SM-8 65 Systematic N/A 1.5 Edge SM-9
-39 Systematic N/A 4.9 Edge SM-10 7
Systematic N/A 3.2 0.1 SM-11
-157 Systematic N/A
- Sample points SM-1 through SM-7 are measured from the nearest beam to the West and to the South of the sample point. The X-Y coordinates for SM-8 through SM-1 1 are measured from the lower left corner of the beam surface on which they lie
Plum Brook Reactor Facility FSSR, Attachment 12 Appendix B Rev. 0, Page 96 of 150 Survey Unit RB-3-32 RB -15' - RB -15' Ceiling Section #9 bU
.ii~
Ez Fi~
0 1
TI I
1 RB-3-32 AREA: RB -15' Elevation, Ceiling Section #9 Measurement Locations and results Location /
X Co-ord (mi)
Y Co-ord (m) dpmll 00-cm 2 Type Notes 2.7 1.4 SM-1 438 Systematic N/A 5.6 1.4 SM-2 170 Systematic N/A 1.2 0.4 SM-3 176 Systematic N/A 4.1 0.4 SM-4 373 Systematic N/A 5.4 0.3 SM-5
-118 Systematic N/A 2.5 0.3 SM-6 7
Systematic N/A 4.0 0.2 SM-7
-150 Systematic N/A 1.0 0.2 SM-8
-157 Systematic N/A 5.4 Edge SM-9 137 Systematic N/A 2.5 Edge SM-10 0
Systematic N/A 2.5 Edge SM-11
-229 Systematic N/A
- Sample points SM-1 through SM-4 are measured from the nearest beam to the West and to the South of the sample point. The X-Y coordinates for SM-5 through SM-1 1 are measured from the lower left corner of the beam surface on which they lie.
Plum Brook Reactor Facility FSSR, Attachment 12 Appendix B Rev. 0, Page 97 of 150 Survey Unit RB-3-33 RB -15' - RB -15' Ceiling Section #10
!119
.l~TS-M:
-1
=11 0
El K
7 171 mll RB-3-33 AREA: RB -15' Elevation, Ceiling Section #10 Measurement Locations and results Location I X Co-ord (m)
Y Co-ord (m) dpm/100-cm2 Type Notes 1.2 Edge SM-1 52 Systematic N/A 4.7 Edge SM-2 144 Systematic N/A 1.8 Edge SM-3 7
Systematic N/A 2.8 Edge SM-4
-7 Systematic N/A 5.7 Edge SM-5
-52 Systematic N/A 1.1 0.1 SM-6 542 Systematic N/A 4.0 0.1 SM-7 497 Systematic N/A 2.5 0.5 SM-8 359 Systematic N/A 5.4 0.5 SM-9 471 Systematic N/A 1.1 1.6 SM-10 131 Systematic N/A 4.0 1.6 SM-11 320 Systematic N/A
- Sample points SM-1 through SM-5 are measured from the lower left corner of the beam surface on which they lie. The X-Y coordinates for SM-6 through SM-1 1 are measured from the nearest beam to the West and to the South of the sample point.
Plum Brook Reactor Facility FSSR, Attachment 12 Appendix B Rev. 0, Page 98 of 150 Survey Unit RB-3-34 RB -15' - RB -15' Ceiling Section #11 I,-
'H~F 7.III RB-3-34 AREA: RB -15' Elevation, Ceiling Section #11 Measurement Locations and results Location /
X Co-ord (m)
Y Co-ord (m) dpm/1 00-cm2 Type Notes 3.5 Edge SM-1
-7 Systematic N/A 0.4 Edge SM-2 294 Systematic N/A 2.5 Edge SM-3 59 Systematic N/A 5.2 Edge SM-4 46 Systematic N/A 0.9 0.4 SM-5 105 Systematic N/A 2.7 2.4 SM-6 353 Systematic N/A 5.8 2.4 SM-7 412 Systematic N/A 1.1 2.4 SM-8 451 Systematic N/A 4.3 2.4 SM-9 503 Systematic N/A 1.1 2.4 SM-10 412 Systematic N/A 4.2 2.4 SM-11 314 Systematic N/A
- Sample points SM-1 through SM-5 are measured from the lower left corner of the beam surface on which they lie nearest. The X-Y coordinates for SM-6 through SM-1 1 are measured from the beam to the West and to the South of the sample point.
Plum Brook Reactor Facility FSSR, Attachment 12 Appendix B Rev. 0, Page 99 of 150 Survey Unit RB-3-35 RB -15' - RB -15' Ceiling Section #12 I
uwý Fil Fi RB-3-35 AREA: RB -15' Elevation, Ceiling Section #12 Measurement Locations and results Location /
X Co-ord (m)
Y Co-ord (m) dpmll 00-cm2 Type Notes 0.5 2.5 SM-1 412 Systematic N/A 0.3 0.3 SM-2 497 Systematic N/A 0.4 1.0 SM-3 477 Systematic N/A 0.5 2.2 SM-4 78 Systematic N/A 4.2 Edge SM-5 359 Systematic N/A 1.1 Edge SM-6
-72 Systematic N/A 1.7 Edge SM-7 98 Systematic N/A 5.8 Edge SM-8 222 Systematic N/A 2.8 Edge SM-9 183 Systematic N/A 4.9 0.4 SM-10
-59 Systematic N/A 1.8 0.4 SM-11 170 Systematic N/A
- Sample points SM-i through SM-4 are measured from the nearest beam to the West and to the South of the sample point, or the point shown on the map. The X-Y coordinates for SM-5 through SM-1 1 are measured from the lower left corner of the beam surface on which they lie.
Plum Brook Reactor Facility FSSR, Attachment 12 Appendix B Rev. 0, Page 100 of 150 Survey Unit RB-3-36 RB -15' - RB -15' Ceiling Section #13 tI M-
- Iswl1, L I
.Iim
~ji~
RB-3-36 AREA: RB -15' Elevation, Ceiling Section #13 Measurement Locations and results Location I X Co-ord (m)
Y Co-ord (m) dpm/l00-cm 2 Type Notes 1.1 2.2 SM-1 614 Systematic N/A 0.9 2.2 SM-2 386 Systematic N/A 0.4 4.8 SM-3 222 Systematic N/A 1.4 4.8 SM-4 444 Systematic N/A 5.7 Edge SM-5 59 Systematic N/A 0.4 Edge SM-6
-111 Systematic N/A 3.0 Edge SM-7 144 Systematic N/A 0.4 Edge SM-8 46 Systematic N/A 5.6 edge SM-9 209 Systematic N/A 1.1 0.3 SM-10 85 Systematic N/A 4.1 0.3 SM-i1 190 Systematic N/A d
S ample points SM-I tnrougn SI-q are measurea from tne nearest Deam to tne West and to the South of the sample point. The X-Y coordinates for SM-5 through SM-1 1 are measured from the lower left corner of the beam surface on which they lie.
Plum Brook Reactor Facility FSSR, Attachment 12 Appendix B Rev. 0, Page 101 of 150 Survey Unit RB-3-37 RB -15' - RB -15' Ceiling Section #14 S M-I L~~j L~J SM-l I RB-3-37 AREA: RB -15' Elevation, Ceiling Section #14 Measurement Locations and results Location I X Co-ord (m)
Y Co-ord (m) dpmll 00-cm2 Type Notes 1.6 Edge SM-1
-163 Systematic N/A 1.5 0.2 SM-2 222 Systematic N/A 1.5 0.3 SM-3 144 Systematic N/A 5.6 Edge SM-4
-39 Systematic N/A 2.8 Edge SM-5 26 Systematic N/A 2.9 Edge SM-6
-78 Systematic N/A Edge Edge SM-7
-59 Systematic N/A 1.0 1.6 SM-8 327 Systematic N/A Edge 1.6 SM-9 52 Systematic N/A 0.3 1.6 SM-10 438 Systematic N/A 0.3 1.6 SM-11
-1248 Systematic N/A
- Sample points SM-1 through SM-7 are measured from the nearest beam to the West and to the South of the sample point. The X-Y coordinates for SM-8 through SM-1 1 are measured from the lower left corner of the beam surface on which they lie.
Th-M4 Plum Brook Reactor Facility FSSR, Attachment 12 Appendix B Rev. 0, Page 102 of 150 Survey Unit RB-3-38 RB -15' - RB -15' East Columns SM-I I
RB-3-38 AREA: RB -15' Elevation, East Columns Measurement Locations and results Location /
X Co-ord (m)
Y Co-ord (,m) dpmll00-cm2 Type Notes Edge 4.0 SM-1 182 Systematic N/A Edge 1.5 SM-2 15 Systematic N/A Edge 0.8 SM-3 117 Systematic N/A Edge 2.8 SM-4 139 Systematic N/A Edge 1.7 SM-5
-139 Systematic N/A Edge 1.0 SM-6
-146 Systematic N/A Center 1.0 SM-7
-36 Systematic N/A Center 3.8 SM-8 0
Systematic N/A Edge 2.1 SM-9
-139 Systematic N/A Edge 3.1 SM-10 328 Systematic N/A Edge 3.1 SM-11 117 Systematic N/A
- Sample measurements are from the lower left corner of the surface on which they lie.
Plum Brook Reactor Facility FSSR, Attachment 12 Appendix B Rev. 0, Page 103 of 150 Survey Unit RB-3-39 RB -15' - West Columns SM i
Z.111 M.
SM-U1HI1-T1 IM-I RB-3-39 AREA: RB -15' Elevation, West Columns Measurement Locations and results Location I X Co-ord (m)
Y Co-ord (m) dpm/100-cm2 Type Notes 0.2 1.9 SM-1
-73 Systematic N/A 0.2 3.9 SM-2
-51 Systematic N/A Edge 3.9 SM-3 350 Systematic N/A 0.2 1.0 SM-4
-80 Systematic N/A Center 3.1 SM-5 190 Systematic N/A Edge 0.2 SM-6 168 Systematic N/A Edge 1.9 SM-7 226 Systematic N/A 0.2 2.2 SM-8
-153 Systematic N/A Edge 2.2 SM-9
-95 Systematic N/A Center 3.9 SM-10
-190 Systematic N/A Edge 4.2 SM-11
-80 Systematic N/A
- Measurements are taken from the lower left corner of the surface on which they lie.
Plum Brook Reactor Facility FSSR, Attachment 12 Appendix B Rev. 0, Page 104 of 150 Survey Unit RB-4-1 Canal F - Floor I
RB-4-1 AREA: Canal F Floor Measurement Locations and results Location /
X Co-ord (im) Y Co-ord (m) dpm/1 00-cm 2 Type Notes 2.1 1.1 SM-1 1087 Systematic N/A 0.9 3.1 SM-2 680 Systematic N/A 3.2 3.1 SM-3 380 Systematic N/A 2.1 5.0 SM-4 413 Systematic N/A 4.3 5.0 SM-5 647 Systematic N/A Center 0.7 SM-6 420 Systematic N/A 0.9 7.0 SM-7 687 Systematic N/A 3.2 7.0 SM-8 520 Systematic N/A 2.1 8.9 SM-9 493 Systematic N/A 0.9 10.9 SM-10 1047 Systematic N/A 3.2 10.9 SM-11 767 Systematic N/A Sample measurements are taken from the southwest corner of the survey unit, except SM-6, which is measured from the southwest comer of the doorway surface on which it lies.
Plum Brook Reactor Facility FSSR, Attachment 12 Appendix B Rev. 0, Page 105 of 150 Survey Unit RB-4-2 Canal F - West and North Walls RB-4-2 AREA: Canal F - West and North Walls Measurement Locations and results Location /
X Co-ord (m)
Y Co-ord (m) dpm/100-cm 2 Type Notes 1.8 0.4 SM-1 657 Systematic N/A 4.9 0.4 SM-2 685 Systematic N/A 8.1 0.4 SM-3 378 Systematic N/A 0.2 3.2 SM-4 797 Systematic N/A 3.4 3.2 SM-5 119 Systematic N/A 6.5 3.2 SM-6 643 Systematic N/A 9.7 3.2 SM-7 434 Systematic N/A 1.8 5.9 SM-8 336 Systematic N/A 4.9 5.9 SM-9 573 Systematic N/A 8.1 5.9 SM-10 580 Systematic N/A 0.6 5.9 SM-1 1 748 Systematic N/A Sample measurements are taken from the lower left corner of the wall surface on which they rest.
Plum Brook Reactor Facility FSSR, Attachment 12 Appendix B Rev. 0, Page 106 of 150 Survey Unit RB-4-3 Canal F - East Wall and F-J Doorway Sides zo
-I\\j SM SM-0 RB-4-3 AREA: Canal F - East Wall and F-J Doorway Sides Measurement Locations and results Location /
X Co-ord (m)
Y Co-ord (m) dpm/1 00-cm 2 Type Notes Edge 2.5 SM-1 259 Systematic N/A Edge 5.3 SM-2 273 Systematic N/A 0.3 0.4 SM-3 776 Systematic N/A 2.6 0.4 SM-4 650 Systematic N/A 3.0 0.4 SM-5 755 Systematic N/A 0.9 3.2 SM-6 420 Systematic N/A 1.4 3.2 SM-7 413 Systematic N/A Center 3.2 SM-8 559 Systematic N/A 0.3 6.0 SM-9 650 Systematic N/A 2.6 6.0 SM-10 902 Systematic N/A 3.0 6.0 SM-11 699 Systematic N/A Sample measurements are taKen Trom the lower lert corner or me surrace on wnicn tney rest.
Plum Brook Reactor Facility FSSR, Attachment 12 Appendix B Rev. 0, Page 107 of 150 Survey Unit RB-4-4 Canal F - Catwalk Underside and Steel Loerleft omer 01r I -
4 -
4
~Lower left corner]
RB-4-4 AREA: Canal F - Catwalk Underside and Steel Measurement Locations and results Location I X Co-ord (im) Y Co-ord (m) dpm/1 00-cm2 Type Notes 1.3 1.2 SM-1 1410 Systematic N/A 2.4 0.4 SM-2 293 Systematic N/A 3.2 0.6 SM-3 693 Systematic N/A 3.2 0.15 SM-4 1180 Systematic N/A 1.4 1.4 SM-5 833 Systematic N/A 0.2 Edge SM-6 87 Systematic N/A 2.3 Edge SM-7 133 Systematic N/A 1.2 Edge SM-8 73 Systematic N/A 3.4 Edge SM-9 200 Systematic N/A Edge Edge SM-1 0
-287 Systematic N/A 0.4 Edge SM-1 1
-133 Systematic N/A Sample measurements are taken from the lower left corner of the survey unit.
Plum Brook Reactor Facility FSSR, Attachment 12 Appendix B Rev. 0, Page 108 of 150 Survey Unit RB-4-5 Canal G - Floor and G-H Doorway SMIl RB-4-5 AREA: Canal G - Floor and G-H Doorway Measurement Locations and results Location I X Co-ord (m)
Y Co-ord (m) dpml 00-cm2 Type Notes 0.0 2.0 SM-1 980 Systematic N/A 2.5 2.0 SM-2 633 Systematic N/A 4.9 2.0 SM-3 740 Systematic N/A 7.3 2.0 SM-4 580 Systematic N/A 9.7 2.0 SM-5 680 Systematic N/A 1.2 4.1 SM-6 920 Systematic N/A 3.7 4.1 SM-7 993 Systematic N/A 6.1 4.1 SM-8 600 Systematic N/A 8.5 4.1 SM-9 633 Systematic N/A 10.9 4.1 SM-10 633 Systematic N/A Edge 1.0 SM-1 1 767 Systematic N/A Sample measurements are taken from the Southwest corner of the survey unit, except SM-1 1, which is measured from the south end of the doorway.
Plum Brook Reactor Facility FSSR, Attachment 12 Appendix B Rev. 0, Page 109 of 150 Survey Unit RB-4-6 Canal G - North Wall RB-4-6 AREA: Canal G - North Wall Measurement Locations and results Location /
X Co-ord (m)
Y Co-ord (m) dpm/1 00-cm2 Type Notes 1.2 1.1 SM-1 484 Systematic N/A 4.1 1.1 SM-2 484 Systematic N/A 7.1 1.1 SM-3 503 Systematic N/A 10.1 1.1 SM-4 516 Systematic N/A 2.6 3.6 SM-5 484 Systematic N/A 5.6 3.6 SM-6 379 Systematic N/A 8.6 3.6 SM-7 451 Systematic N/A 1.2 6.2 SM-8 765 Systematic N/A 4.1 6.2 SM-9 451 Systematic N/A 7.1 6.2 SM-10 418 Systematic N/A 10.1 6.2 SM-11 431 Systematic N/A Sample measurements are taken from the lower left corner of the survey unit.
Plum Brook Reactor Facility FSSR, Attachment 12 Appendix B Rev. 0, Page 110 of 150 Survey Unit RB-4-7 Canal G - East and West Walls and Lower 4m of South Wall 1~ii IBM-%
ism4 M-fl RB-4-7 AREA: Canal G - East and West Walls and Lower 4m of South Wall Measurement Locations and results Location /
X Co-ord (im) Y Co-ord (im) dpmll 00-cm 2 Type Notes Edge 5.1 SM-1 111 Systematic N/A 0.1 2.4 SM-2 490 Systematic N/A 1.3 1.8 SM-3 451 Systematic N/A 1.3 7.2 SM-4 209 Systematic N/A 2.9 0.1 SM-5 529 Systematic N/A 6.0 0.1 SM-6 765 Systematic N/A 9.1 0.1 SM-7 948 Systematic N/A 1.4 2.7 SM-8 216 Systematic N/A 4.5 2.7 SM-9 333 Systematic N/A 7.6 2.7 SM-10 745 Systematic N/A 10.7 2.7 SM-11 386 Systematic N/A Sample measurements are taken from the lower left corner of the wall surface on which they lie.
Plum Brook Reactor Facility FSSR, Attachment 12 Appendix B Rev. 0, Page 111 of 150 Survey Unit RB-4-8 Canal G - South Wall above 2m and G and H Ceiling t=
r3 r--
0
~
00 0
00*-
0
==
-=
DOD 41H
ý ~
RB-4-8 AREA: Canal G - South Wall above 2m and G and H Ceiling Measurement Locations and results Location I X Co-ord (mi)
Y Co-ord (mi) dpm/100-cm 2 Type Notes 1.0 4.1 SM-1 839 Systematic N/A 3.7 4.1 SM-2 678 Systematic N/A 6.5 4.1 SM-3 755 Systematic N/A 9.2 4.1 SM-4 671 Systematic N/A 2.3 6.5 SM-5 713 Systematic N/A 5.1 6.5 SM-6 1077 Systematic N/A 7.8 6.5 SM-7 587 Systematic N/A 10.6 6.5 SM-8 566 Systematic N/A 2.3 Edge SM-9
-28 Systematic N/A 5.1 Edge SM-10 287 Systematic N/A 0.2 2.1 SM-11 552 Systematic N/A Sample measurements are taken from the lower left or southwest corner of the surface on which they lie.
Plum Brook Reactor Facility FSSR, Attachment 12 Appendix B Rev. 0, Page 112 of 150 Survey Unit RB-4-9 Canal H - Floor RB-4-9 AREA: Canal H - Floor Measurement Locations and results Location /
X Co-ord (m)
Y Co-ord (m) dpml1 00-cm2 Type Notes 0.1 1.1 SM-1 887 Systematic N/A 2.2 1.1 SM-2 613 Systematic N/A 4.3 1.1 SM-3 700 Systematic N/A 6.4 1.1 SM-4 560 Systematic N/A 1.2 3.0 SM-5 767 Systematic N/A 3.3 3.0 SM-6 1327 Systematic N/A 5.4 3.0 SM-7 827 Systematic N/A 0.1 4.8 SM-8 420 Systematic N/A 2.2 4.8 SM-9 633 Systematic N/A 4.3 4.8 SM-10 633 Systematic N/A 6.4 4.8 SM-11 767 Systematic N/A Sample measurements are taken from the point shown on the map.
Plum Brook Reactor Facility FSSR, Attachment 12 Appendix B Rev. 0, Page 113 of 150 Survey Unit RB-4-10 Canal H - West and North Walls and G-H Doorway Sides o
i SM-Il I
I RB-4-10 AREA: Canal H - West and North Walls and G-H Doorway Sides Measurement Locations and results Location /
X Co-ord (m)
Y Co-ord (m) dpm/100-cm 2 Type Notes Edge 2.1 SM-1
-182 Systematic N/A Edge 4.9 SM-2
-7 Systematic N/A Edge 1.9 SM-3 629 Systematic N/A 0.3 1.9 SM-4 252 Systematic N/A 3.5 1.9 SM-5 552 Systematic N/A 0.7 4.6 SM-6 399 Systematic N/A 1.9 4.6 SM-7 545 Systematic N/A 5.1 4.6 SM-8 853 Systematic N/A Edge 7.4 SM-9 112 Systematic N/A 0.3 7.4 SM-10 1090 Systematic N/A 3.5 7.4 SM-1 1 476 Systematic N/A Sample measurements are taken from the lower left corner of the surface on which they lie.
Plum Brook Reactor Facility FSSR, Attachment 12 Appendix B Rev. 0, Page 114 of 150 Survey Unit RB-4-11 Canal H - South and East Walls 717 I
13
~ti~
0
~MA1 ISM-RB-4-11 AREA: Canal H - South and East Walls Measurement Locations and results Location I X Co-ord (m)
Y Co-ord (m) dpmll 00-cm 2 Type Notes 0.4 0.1 SM-1 734 Systematic N/A 3.5 0.1 SM-2 315 Systematic N/A 6.6 0.1 SM-3 615 Systematic N/A 1.9 2.8 SM-4 762 Systematic N/A 5.0 2.8 SM-5 462 Systematic N/A 0.4 5.5 SM-6 601 Systematic N/A 3.5 5.5 SM-7 350 Systematic N/A 6.6 5.5 SM-8 636 Systematic N/A 3.0 2.6 SM-9 483 Systematic N/A 1.4 5.3 SM-10 608 Systematic N/A 4.5 5.3 SM-11 678 Systematic N/A Sample measurements are taken from the lower left corner of the surface on which they lie.
Plum Brook Reactor Facility FSSR, Attachment 12 Appendix B Rev. 0, Page 115 of 150 Survey Unit RB-4-12 RB -25' - Trench Floor outside of the PPP Room RB-4-12 AREA: RB -25' Elevation, Trench Floor outside of the PPP Room Measurement Locations and results Location /
X Co-ord (m)
Y Co-ord (m) dpmll 00-cm 2 Type Notes 6.4 0.05 SM-1 916 Systematic N/A 4.2 0.05 SM-2 490 Systematic N/A 1.9 0.05 SM-3 650 Systematic N/A 1.0 2.3 SM-4 517 Systematic N/A 1.0 6.2 SM-5 1020 Systematic N/A 3.3 6.2 SM-6 713 Systematic N/A 2.1 8.1 SM-7 2100 Systematic N/A 0.1 0.5 SM-8 664 Systematic N/A 0.1 0.5 SM-9 776 Systematic N/A 0.1 0.8 SM-10 636 Systematic N/A 0.1 0.8 SM-11 517 Systematic N/A Sample Measurements are taken from the locations shown on the map for the trench bottom, and the lower left corner of the surface on which they lie for the pit sides.
Plum Brook Reactor Facility FSSR, Attachment 12 Appendix B Rev. 0, Page 116 of 150 Survey Unit RB-4-13 RB -25' - Trench Walls outside of the PPP Room F El H H H Bku L-I 0
0 00 0
ý--l I 1
%0 TSM-
"MM RB-4-13 AREA: RB -25' Elevation, Trench Walls outside of the PPP Room Measurement Locations and results Location /
X Co-ord (m)
Y Co-ord (m) dpm/100-cm 2 Type Notes 1.1 0.05 SM-1 273 Systematic N/A 1.2 0.5 SM-2 608 Systematic N/A 5.0 0.5 SM-3 706 Systematic N/A 8.7 0.5 SM-4 217 Systematic N/A 1.1 0.9 SM-5 1150 Systematic N/A 3.8 0.9 SM-6 762 Systematic N/A 2.8 0.8 SM-7 734 Systematic N/A 1.0 0.7 SM-8 790 Systematic N/A 0.9 0.7 SM-9 510 Systematic N/A 1.6 0.7 SM-10 399 Systematic N/A 0.6 0.3 SM-11 399 Systematic N/A 1.1 0.3 SM-12 119 Systematic N/A Sample measurements are taken from the lower left corner of the surface on which they lie.
Plum Brook Reactor Facility FSSR, Attachment 12 Appendix B Rev. 0, Page 117 of 150 Survey Unit RB-4-14 RB -25' - Floor Section #1 - East Floor
_q Sample Measurements are taken from this point.
Y RB-4-14 AREA: RB -25' Elevation, Floor Section #1 - East Floor Measurement Locations and results Location /
X Co-ord (m)
Y Co-ord (im) dpm/100-cm2 Type Notes
-1.9 1.5 SM-1 898 Systematic N/A 0.9 1.5 SM-2 599 Systematic N/A
-6.1 4.0 SM-3 854 Systematic N/A
-3.3 4.0 SM-4 1088 Systematic N/A
-0.5 4.0 SM-5 876 Systematic N/A
-7.5 6.4 SM-6 555 Systematic N/A
-4.7 6.4 SM-7 1051 Systematic N/A
-8.9 8.8 SM-8 774 Systematic N/A
-6.1 8.8 SM-9 1190 Systematic N/A
-7.5 11.2 SM-10 832 Systematic N/A
-10.3 16.1 SM-I1 599 Systematic N/A Sample measurements are taken from the location shown on the map.
Plum Brook Reactor Facility FSSR, Attachment 12 Appendix B Rev. 0, Page 118 of 150 Survey Unit RB-4-15 RB -25' - Floor Section #2 - SE and South Floor RB-4-15 AREA: RB -25' Elevation, Floor Section #2 - SE and South Floor Measurement Locations and results Location /
X Co-ord (m)
Y Co-ord (m) dpm/100-cm 2
Type Notes 0.4 1.2 SM-1 1029 Systematic N/A 3.2 1.2 SM-2 920 Systematic N/A 1.8 3.6 SM-3 876 Systematic N/A 3.2 6.0 SM-4 934 Systematic N/A 2.5 1.6 SM-5 613 Systematic N/A 5.3 1.6 SM-6 701 Systematic N/A 8.1 1.6 SM-7 927 Systematic N/A 10.9 1.6 SM-8 803 Systematic N/A 6.7 4.0 SM-9 562 Systematic N/A 9.5 4.0 SM-1 219 Systematic N/A 8.1 6.4 SM-11 949 Systematic N/A Sample measurements are taken from the points shown on the map.
Plum Brook Reactor Facility FSSR, Attachment 12 Appendix B Rev. 0, Page 119 of 150 Survey Unit RB-4-16 RB -25' - Floor Section #3 - Center Floor and Pad SM i
SM1 SM.
Measure samplesISM-frmthis point.
II-II I
RB-4-16 AREA: RB -25' Elevation, Floor Section #3 - Center Floor and Pad Measurement Locations and results Location /
X Co-ord (m)
Y Co-ord (m) dpm/ 00-cm 2 Type Notes 1.5
-2.1 SM-1 620 Systematic N/A 4.3
-2.1 SM-2 1204 Systematic N/A 1.5 0.1 SM-3 482 Systematic N/A 4.3 0.1 SM-4 628 Systematic N/A 0.1 2.5 SM-5 774 Systematic N/A 2.9 2.5 SM-6 839 Systematic N/A 5.7 2.5 SM-7 869 Systematic N/A 8.4 2.5 SM-8 759 Systematic N/A 1.5 4.9 SM-9 701 Systematic N/A 4.3 4.9 SM-10 759 Systematic N/A 7.0 4.9 SM-11 606 Systematic N/A Sample Measurements are taken from the point shown on the map.
Plum Brook Reactor Facility FSSR, Attachment 12 Appendix B Rev. 0, Page 120 of 150 Survey Unit RB-4-17 RB -25' - Floor Section #4 - North Floor and Stairway DD DODo D
IflIhI[HU Th11fC1 WIW-0 199
=
0 L
RB-4-17 AREA: RB -25' Elevation, Floor Section #4 - North Floor and Stairway Measurement Locations and results Location /
X Co-ord (m)
Y Co-ord (m) dpmll 00-cm2 Type Notes 1.8 0.1 SM-1 102 Systematic N/A 0.5 0.1 SM-2 124 Systematic N/A 0.5 center SM-3
-161 Systematic N/A 0.5 edge SM-4 102 Systematic N/A 0.2 0.1 SM-5 496 Systematic N/A 0.2 0.2 SM-6 985 Systematic N/A 0.4 0.6 SM-7 745 Systematic N/A 1.3 0.8 SM-8 891 Systematic N/A 4.8 0.8 SM-9 336 Systematic N/A 8.3 0.8 SM-10 1022 Systematic N/A 3.1 3.8 SM-11 825 Systematic N/A Measurements for SM-1 through SM-7 are taken from the lower left corner of the surface on which they lie, measurements for SM-8 through SM-1 1 are taken from the southwest corner of the survey unit.
Plum Brook Reactor Facility FSSR, Attachment 12 Appendix B Rev. 0, Page 121 of 150 Survey Unit RB-4-18 RB -25' - PPP Room Trench and Pipe Chase I
RB-4-18 AREA: RB -25' Elevation, PPP Room Trench and Pipe Chase Measurement Locations and results Location /
X Co-ord (m)
Y Co-ord (m) dpm/100-cm 2 Type Notes Edge 1.9 SM-1 1160 Systematic N/A Edge 6.6 SM-2 3920 Systematic N/A 0.3 1.4 SM-3 908 Systematic N/A 0.1 1.4 SM-4 789 Systematic N/A 1.5 1.4 SM-5 1200 Systematic N/A 0.6 3.7 SM-6 845 Systematic N/A 1.7 3.7 SM-7 817 Systematic N/A 0.2 3.7 SM-8 930 Systematic N/A 0.3 Edge SM-9 521 Systematic N/A 0.5 6.0 SM-10 606 Systematic N/A 1.6 6.0 SM-11 507 Systematic N/A Sample measurements for SM-1 and SM-2 are taken from the point shown on the map.
Measurements for SM-3 through SM-11 are taken from the lower left corner of the surface on which they lie.
Plum Brook Reactor Facility FSSR, Attachment 12 Appendix B Rev. 0, Page 122 of 150 Survey Unit RB-4-19 RB -25' - PPP Room Trench Walls o 0 LIZLI 00 00o SM l SM
°MS-S ISM41' VISMIA ISM-S S-NE SMEI RB-4-19 AREA: RB -25' Elevation, PPP Room Trench Walls Measurement Locations and results Location I X Co-ord (r)
Y Co-ord (m) dpm/1 00-cm2 Type Notes 0.1 bottom edge SM-1 1944 Systematic N/A 3.1 SM-2 3387 Systematic N/A 6.1 SM-3 2563 Systematic N/A 0.6 SM-4 1915 Systematic N/A 0.6 SM-5 975 Systematic N/A 0.8 SM-6 1873 Systematic N/A Edge SM-7 563 Systematic N/A 0.8 SM-8 2993 Systematic N/A 0.15 SM-9 3211 Systematic N/A 2.9 SM-10 3408 Systematic N/A 5.9
§M SM-11 5458 Systematic N/A Sample measurements are taken from the lower left corner of the surface on which they lie.
Plum Brook Reactor Facility FSSR, Attachment 12 Appendix B Rev. 0, Page 123 of 150 Survey Unit RB-4-20 RB -25' - PPP Room Floor and Pump Services Trench
~Measure SM-1I from this point.[
Mer I
.S SME-J liij i
Noe 0 0 o O
-Li -Li
- Li
-L SMgý -
0 0.
0. 0 RB-4-20 AREA: RB -25' Elevation, PPP Room Floor and Pump Services Trench Measurement Locations and results Location I X Co-ord (m)
Y Co-ord (m) dpm/100-cm 2 Type Notes 1.7 edge SM-1 797 Systematic N/A 1.0 0.7 SM-2 580 Systematic N/A 3.2 0.7 SM-3 783 Systematic N/A 2.8 0.7 SM-4 629 Systematic N/A 0.15 0.7 SM-5 776 Systematic N/A 3.0 0.7 SM-6 1250 Systematic N/A 0.8 0.7 SM-7 524 Systematic N/A 4.4 0.7 SM-8 1310 Systematic N/A 0.6 1.0 SM-9 1300 Systematic N/A 4.2 1.0 SM-10 1200 Systematic N/A 0.1 Bottom edge SM-11 1420 Systematic N/A Sample measurements for SM-2 through SM-8 are taken from the lower left corner of the surface on which they lie. Measurements for SM-1 and SM-9 through SM-11 are taken from the point shown on the map.
Plum Brook Reactor Facility FSSR, Attachment 12 Appendix B Rev. 0, Page 124 of 150 Survey Unit RB-4-21 RB -25' - Wall Section #1 RB-4-21 AREA: RB -25' Elevation, Wall Section #1 Measurement Locations and results Location /
X Co-ord (m)
Y Co-ord (m) dpm/l 00-cm 2 Type Notes 0.3 1.8 SM-1 469 Systematic N/A 1.7 1.8 SM-2 622 Systematic N/A 4.3 1.8 SM-3 552 Systematic N/A 6.9 1.8 SM-4 497 Systematic N/A 0.4 4.0 SM-5 538 Systematic N/A 3.0 4.0 SM-6 301 Systematic N/A 5.6 4.0 SM-7 336 Systematic N/A 0.3 6.3 SM-8 587 Systematic N/A 1.7 6.3 SM-9 287 Systematic N/A 4.3 6.3 SM-10 483 Systematic N/A 6.9 6.3 SM-1 1 531 Systematic N/A
- All sample measurements are taken from the lower left corner of the surface on which they rest.
Plum Brook Reactor Facility FSSR, Attachment 12 Appendix B Rev. 0, Page 125 of 150 Survey Unit RB-4-22 RB -25' - Wall Section #2 SM.MSM 0
RB-4-22 AREA: RB -25' Elevation, Wall Section #2 Measurement Locations and results Location /
X Co-ord (m)
Y Co-ord (m) dpm/100-cm2 Type Notes 0
0.7 SM-1 406 Systematic N/A 1.9 0.7 SM-2 517 Systematic N/A 0.4 3.3 SM-3 720 Systematic N/A 0
5.9 SM-4 483 Systematic N/A 1.9 0.2 SM-5 622 Systematic N/A 4.9 1.5 SM-6 217 Systematic N/A 1.3 1.5 SM-7 706 Systematic N/A 4.3 1.5 SM-8 720 Systematic N/A 1.2 1.5 SM-9 503 Systematic N/A 4.2 1.5 SM-10 231 Systematic N/A 7.2 1.5 SM-11 126 Systematic N/A
- All sample measurements are taken from the lower left corner of the surface on which they rest.
Plum Brook Reactor Facility FSSR, Attachment 12 Appendix B Rev. 0, Page 126 of 150 Survey Unit RB-4-23 RB -25' - Wall Section #3 SWld RB-4-23 AREA: RB -25' Elevation, Wall Section #3 Measurement Locations and results Location /
X Co-ord (m)
Y Co-ord (im) dpm/100-cm 2 Type Notes 0.7 1.6 SM-1 434 Systematic N/A 3.5 1.6 SM-2 308 Systematic N/A 1.3 1.6 SM-3 853 Systematic N/A 4.2 1.6 SM-4 601 Systematic N/A 0.2 1.6 SM-5 7
Systematic N/A 0.1 1.6 SM-6 434 Systematic N/A 2.1 4.1 SM-7 98 Systematic N/A 5.0 4.1 SM-8 888 Systematic N/A 2.8 4.1 SM-9 490 Systematic N/A 5.6 4.1 SM-10 538 Systematic N/A 1.7 4.1 SM-11 476 Systematic N/A
- All sample measurements are taken from the lower left corner of the surface on which they rest.
Plum Brook Reactor Facility FSSR, Attachment 12 Appendix B Rev. 0, Page 127 of 150 Survey Unit RB-4-24 RB -25' - Wall Section #4 RB-4-24 RB -25' Elevation, Wall Section #4 Measurement Locations and results Location /
X Co-ord (m)
Y Co-ord (m) dpm/100-cm 2 Type Notes 0.2 0.6 SM-1 500 Systematic N/A 3.6 0.6 SM-2 869 Systematic N/A 7.0 0.6 SM-3 1082 Systematic N/A 10.5 0.6 SM-4 434 Systematic N/A 1.9 3.6 SM-5 680 Systematic N/A 5.3 3.6 SM-6 967 Systematic N/A 8.8 3.6 SM-7 492 Systematic N/A 12.2 3.6 SM-8 631 Systematic N/A 0.2 6.5 SM-9 689 Systematic N/A 3.6 6.5 SM-10 246 Systematic N/A 7.0 6.5 SM-11 541 Systematic N/A 10.5 6.5 SM-12 410 Systematic N/A
- All sample measurements are taken from the lower left corner of the surface on which they rest.
Plum Brook Reactor Facility FSSR, Attachment 12 Appendix B Rev. 0, Page 128 of 150 Survey Unit RB-4-25 RB -25' - Wall Section #5 0
0 0
1~i~i 110 F-I F-I RB-4-25 AREA: RB -25' Elevation, Wall Section #5 Measurement Locations and results Location /
X Co-ord (m)
Y Co-ord (m) dpml100-cm2 Type Notes 0.6 0.9 SM-1 434 Systematic N/A 4.0 0.9 SM-2 769 Systematic N/A 7.4 0.9 SM-3 867 Systematic N/A 10.9 0.9 SM-4 420 Systematic N/A 2.3 3.8 SM-5 448 Systematic N/A 5.7 3.8 SM-6 245 Systematic N/A 9.1 3.8 SM-7 615 Systematic N/A 0.6 6.8 SM-8 888 Systematic N/A 4.0 6.8 SM-9 573 Systematic N/A 7.4 6.8 SM-10 273 Systematic N/A 10.9 6.8 SM-11 594 Systematic N/A
- All sample measurements are taken from the lower left corner of the surface on which they rest.
Plum Brook Reactor Facility FSSR, Attachment 12 Appendix B Rev. 0, Page 129 of 150 Survey Unit RB-4-26 RB -25' - Wall Section #6 0
I =Ii LII RB-4-26 AREA: RB -25' Elevation, Wall Section #6 Measurement Locations and results Location I X Co-ord (m)
Y Co-ord (m) dpm/100-cm 2 Type Notes 11.8
-0.3 SM-1 473 Systematic N/A 14.5
-0.3 SM-2 820 Systematic N/A 0.1 2.0 SM-3 426 Systematic N/A 2.5 2.0 SM-4 369 Systematic N/A 2.4 2.0 SM-5 344 Systematic N/A 5.0 2.0 SM-6 295 Systematic N/A 7.7 2.0 SM-7 393 Systematic N/A 10.4 2.0 SM-8 407 Systematic N/A 1.2 4.3 SM-9 197 Systematic N/A 0.1 6.6 SM-10 516 Systematic N/A 2.5 6.6 SM-Il 598 Systematic N/A
- All sample measurements are taken from the lower left corner of the surface on which they rest.
Plum Brook Reactor Facility FSSR, Attachment 12 Appendix B Rev. 0, Page 130 of 150 Survey Unit RB-4-27 RB -25' - Wall Section #7 0
0 0
0 0
0 0
0 0I~
00 RB-4-27 AREA: RB -25' Elevation, Wall Section #7 Measurement Locations and results Location /
X Co-ord (m)
Y Co-ord (m) dpm/I 00-cm2 Type Notes 0.9 1.6 SM-1 113 Systematic N/A 3.5 1.6 SM-2 98 Systematic N/A 6.1 1.6 SM-3 119 Systematic N/A 8.8 1.6 SM-4 140 Systematic N/A 2.2 3.9 SM-5 207 Systematic N/A 4.8 3.9 SM-6
-217 Systematic N/A 7.4 3.9 SM-7
-77 Systematic N/A 0.9 6.2 SM-8
-167 Systematic N/A 3.5 6.2 SM-9
-133 Systematic N/A 6.1 6.2 SM-10
-28 Systematic N/A 8.8 6.2 SM-1 1
-224 Systematic N/A
- All sample measurements are taken from the lower left corner of the surface on which they rest.
Plum Brook Reactor Facility FSSR, Attachment 12 Appendix B Rev. 0, Page 131 of 150 Survey Unit RB-4-28 RB -25' - Wall Section #8 0
- 0 0 RB-4-28 AREA: RB -25' Elevation, Wall Section #8 Measurement Locations and results Location /
X Co-ord (im) Y Co-ord (im) dpmll00-cm Type Notes 0.6 0.9 SM-1
-173 Systematic N/A 4.0 0.9 SM-2
-33 Systematic N/A 7.4 0.9 SM-3
-253 Systematic N/A 10.7 0.9 SM-4
-47 Systematic N/A 2.3 3.8 SM-5 133 Systematic N/A 5.7 3.8 SM-6
-180 Systematic N/A 9.1 3.8 SM-7 167 Systematic N/A 0.6 6.7 SM-8
-87 Systematic N/A 4.0 6.7 SM-9 140 Systematic N/A 7.4 6.7 SM-1
-80 Systematic N/A 10.7 6.7 SM-1 1
-220 Systematic N/A
- All sample measurements are taken from the lower left corner of the surface on which they rest.
Plum Brook Reactor Facility FSSR, Attachment 12 Appendix B Rev. 0, Page 132 of 150 Survey Unit RB-4-29 RB -25' - Columns
~LI I
UD
=U SM I
II SMR SM-RB-4-29 AREA: RB -25' Elevation, Columns Measurement Locations and results Location /
X Co-ord (m)
Y Co-ord (im) dpm/100-cm2 Type Notes Edge 2.0 SM-1
-119 Systematic N/A Edge 4.3 SM-2 266 Systematic N/A Edge 6.7 SM-3
-294 Systematic N/A Edge 1.5 SM-4
-91 Systematic N/A 0.1 1.0 SM-5
-98 Systematic N/A 0.1 3.4 SM-6 42 Systematic N/A Edge 6.2 SM-7
-175 Systematic N/A 0.1 5.7 SM-8
-238 Systematic N/A Edge 1.0 SM-9 63 Systematic N/A Center 3.3 SM-10
-67 Systematic N/A Edge 5.7 SM-11 287 Systematic N/A
- All sample measurements are taken from the lower left corner of the surface on which they rest.
Plum Brook Reactor Facility FSSR, Attachment 12 Appendix B Rev. 0, Page 133 of 150 Survey Unit RB-4-30 RB -25'-Pump Room Mezzanine
3 EJ r
=
0 0
RB-4-30 AREA: RB -25' Elevation, Pump Room Mezzanine Measurement Locations and results Location /
X Co-ord (m)
Y Co-ord (m) dpm/100-cm2 Type Notes 0.7 1.4 SM-1 573 Systematic N/A 3.4 1.4 SM-2 587 Systematic N/A 6.0 1.4 SM-3 678 Systematic N/A 8.6 1.4 SM-4 1042 Systematic N/A 2.0 3.6 SM-5 615 Systematic N/A 4.7 3.6 SM-6 490 Systematic N/A 7.3 3.6 SM-7 462 Systematic N/A 0.7 5.9 SM-8 510 Systematic N/A 3.4 5.9 SM-9 490 Systematic N/A 6.0 5.9 SM-10 657 Systematic N/A 2.0 8.2 SM-1 1 769 Systematic N/A
- Sample measurements are taken from the southwest corner of the survey unit.
Plum Brook Reactor Facility FSSR, Attachment 12 Appendix B Rev. 0, Page 134 of 150 Survey Unit RB-4-31 RB -25' - Pump Room South and West Walls RB-4-31 AREA: RB -25' Elevation, Pump Room South and West Walls Measurement Locations and results Location /
X Co-ord (m)
Y Co-ord (m) dpm/1 00-cm 2 Type Notes 0.9 0.9 SM-1 640 Systematic N/A 4.2 0.9 SM-2 1079 Systematic N/A 7.5 0.9 SM-3 683 Systematic N/A 1.5 0.9 SM-4 669 Systematic N/A 4.8 0.9 SM-5 878 Systematic N/A 0.5 0.9 SM-6 345 Systematic N/A 2.5 3.8 SM-7 1094 Systematic N/A 5.8 3.8 SM-8 511 Systematic N/A 0.15 3.8 SM-9 619 Systematic N/A 3.2 3.8 SM-10 676 Systematic N/A 6.5 3.8 SM-11 561 Systematic N/A
- Sample measurements are taken from the lower left corner of the surface on which they lie.
Plum Brook Reactor Facility FSSR, Attachment 12 Appendix B Rev. 0, Page 135 of 150 Survey Unit RB-4-32 RB -25' - Pump Room North, Northeast and East Walls ii
- kii
- kii RB-4-32 RB -25' Elevation, Pump Room North, Northeast and East Walls Measurement Locations and results Location /
X Co-ord (m)
Y Co-ord (m) dpm/100-cm 2 Type Notes 0.8 1.5 SM-1 691 Systematic N/A 3.3 1.5 SM-2 374 Systematic N/A 5.7 1.5 SM-3 223 Systematic N/A 1.1 1.5 SM-4 259 Systematic N/A 3.6 1.5 SM-5 719 Systematic N/A 0.1 3.6 SM-6
-36 Systematic N/A Edge 3.6 SM-7 482 Systematic N/A 2.0 3.6 SM-8 173 Systematic N/A 4.5 3.6 SM-9 417 Systematic N/A 0.1 3.6 SM-10 453 Systematic N/A 2.3 3.6 SM-11 453 Systematic N/A Sample measurements are taken Trom tne lower left corner of tne surrace on wnicn they lie.
Plum Brook Reactor Facility FSSR, Attachment 12 Appendix B Rev. 0, Page 136 of 150 Survey Unit RB-4-33 RB -25'- Pump Room Ceiling
=
IiF_
I
'm'1 j
RB-4-33 AREA: RB -25' Elevation, Pump Room Ceiling Measurement Locations and results Location i X Co-ord (m)
Y Co-ord (m) dpmll 00-cm Type Notes 1.9 Edge SM-1 1036 Systematic N/A 4.9 Edge SM-2 604 Systematic N/A 7.9 Edge SM-3 662 Systematic N/A 1.3 Edge SM-4 554 Systematic N/A 1.4 0.5 SM-5 561 Systematic N/A 4.3 0.5 SM-6 755 Systematic N/A 7.3 0.5 SM-7 878 Systematic N/A 2.8 3.1 SM-8 417 Systematic N/A 5.8 3.1 SM-9 683 Systematic N/A 1.4 5.7 SM-10 489 Systematic N/A 4.3 5.7 SM-11 1144 Systematic N/A
- Sample measurements for SM-1 through SM-4 are taken from the lower left corner of the surface on which they lie. Measurements for SM-5 through SM-1 1 are taken from the southwest comer of the ceiling.
Plum Brook Reactor Facility FSSR, Attachment 12 Appendix B Rev. 0, Page 137 of 150 Survey Unit RB-4-34 RB -25' - Ceiling Section #1 RB-4-34 AREA: RB -25' Elevation, Ceiling Section #1 Measurement Locations and results Location /
X Co-ord (m)
Y Co-ord (m) dpmll00-cm 2 Type Notes 0.9 0.7 SM-1 344 Systematic N/A 1.5 0.7 SM-2 441 Systematic N/A 0.2 0.7 SM-3 552 Systematic N/A 0.7 0.7 SM-4 533 Systematic N/A 1.4 Edge SM-5 49 Systematic N/A 4.2 Edge SM-6 210 Systematic N/A 2.5 Edge SM-7
-240 Systematic N/A 0.7 0.3 SM-8
-49 Systematic N/A 0.7 0.1 SM-9
-105 Systematic N/A 0.7 0.2 SM-1 0 373 Systematic N/A 0.7 0.3 SM-1 1 227 Systematic N/A
- Sample measurements are taken from the southwest corner or the lower left comer of the surface on which they lie.
Plum Brook Reactor Facility FSSR, Attachment 12 Appendix B Rev. 0, Page 138 of 150 Survey Unit RB-4-35 RB -25' - Ceiling Section #2 Lý LýLr RB-4-35 AREA: RB -25' Elevation, Ceiling Section #2 Measurement Locations and results Location /
X Co-ord (m)
Y Co-ord (m) dpmll00-cm 2 Type Notes 0.5 2.5 SM-1 336 Systematic N/A 1.7 2.5 SM-2 329 Systematic N/A 0.6 2.5 SM-3 566 Systematic N/A 1.0 5.3 SM-4 441 Systematic N/A 0.1 5.3 SM-5 315 Systematic N/A 1.3 5.3 SM-6 657 Systematic N/A 2.2 5.3 SM-7 706 Systematic N/A 1.6 0.2 SM-8 14 Systematic N/A 4.5 Edge SM-9
-77 Systematic N/A 4.5 Edge SM-10 175 Systematic N/A 1.7 0.3 SM-11 315 Systematic N/A
- Sample measurements are taken from the lower left corner or the southwest corner of the surface on which they lie.
Plum Brook Reactor Facility FSSR, Attachment 12 Appendix B Rev. 0, Page 139 of 150 Survey Unit RB-4-36 RB -25' - Ceiling Section #3
- W5 L
-J
-I I
I" "1 RB-4-36 AREA: RB -25' Elevation, Ceiling Section #3 Measurement Locations and results Location /
X Co-ord (im) Y Co-ord (m) dpm/1 00-cm 2 Type Notes 0.9 2.0 SM-1 441 Systematic N/A 1.5 4.7 SM-2 622 Systematic N/A 0.5 4.7 SM-3 448 Systematic N/A Edge 2.2 SM-4 21 Systematic N/A 4.2 0.1 SM-5 35 Systematic N/A 4.6 Edge SM-6 14 Systematic N/A 0.6 Centered SM-7 126 Systematic N/A 3.7 Centered SM-8 7
Systematic N/A 6.9 Centered SM-9 182 Systematic N/A 2.3 0.3 SM-10
-259 Systematic N/A 5.4 0.3 SM-11 161 Systematic N/A
- Sample measurements are taken from the lower left corner or the southwest corner of the surface on which they lie.
Plum Brook Reactor Facility FSSR, Attachment 12 Appendix B Rev. 0, Page 140 of 150 Survey Unit RB-4-37 RB -25' - Ceiling Section #4
%a
- W9
'U93 H
t4 U
RB-4-37 AREA: RB -25' Elevation, Ceiling Section #4 Measurement Locations and results Location /
X Co-ord (m)
Y Co-ord (m) dpm/100-cm 2 Type Notes 3.9 Edge SM-1
-14 Systematic N/A 3.9 0.4 SM-2
-175 Systematic N/A 0.1 Edge SM-3
-28 Systematic N/A 0.4 0.3 SM-4
-133 Systematic N/A 3.5 0.3 SM-5 35 Systematic N/A 6.7 0.3 SM-6 0
Systematic N/A 1.4 1.6 SM-7 615 Systematic N/A 1.6 1.6 SM-8 357 Systematic N/A 2.0 1.1 SM-9 448 Systematic N/A 0.1 4.2 SM-10 357 Systematic N/A 0.4 3.8 SM-11 469 Systematic N/A
- Sample measurements are taken from the lower left corner or the southwest corner of the surface on which they lie.
Plum Brook Reactor Facility FSSR, Attachment 12 Appendix B Rev. 0, Page 141 of 150 Survey Unit RB-4-38 RB -25' - Ceiling Section #5 m=l RB-4-38 AREA: RB -25' Elevation, Ceiling Section #5 Measurement Locations and results Location /
X Co-ord (m)
Y Co-ord (m) dpm/1 00-cm 2 Type Notes 0.8 0.1 SM-1 615 Systematic N/A 1.8 1.1 SM-2 210 Systematic N/A 0.4 3.8 SM-3 559 Systematic N/A 2.4 Edge SM-4 93 Systematic N/A 9.3 0.4 SM-5 63 Systematic N/A 5.6 Edge SM-6 245 Systematic N/A 1.4 0.4 SM-7
-70 Systematic N/A 2.2 Edge SM-8 245 Systematic N/A 3.3 0.2 SM-9 21 Systematic N/A 2.8 Edge SM-10 238 Systematic N/A 5.8 0.3 SM-11
-49 Systematic N/A
- Sample measurements are taken from the lower left or the southwest corner of the surface on which they lie, except SM-1, which is measured from the point shown on the map.
Plum Brook Reactor Facility FSSR, Attachment 12 Appendix B Rev. 0, Page 142 of 150 Survey Unit RB-4-39 RB -25' - Ceiling Section #6 RB-4-39 AREA: RB -25' Elevation, Ceiling Section #6 Measurement Locations and results Location I X Co-ord (m)
Y Co-ord (m) dpmll 00-cm2 Type Notes 2.6 1.5 SM-1 545 Systematic N/A 5.6 1.5 SM-2 448 Systematic N/A 8.6 1.5 SM-3 671 Systematic N/A 1.2 1.0 SM-4 573 Systematic N/A 4.2 1.0 SM-5 510 Systematic N/A 2.7 Edge SM-6 42 Systematic N/A 5.7 Edge SM-7 84 Systematic N/A 8.7 Edge SM-8 21 Systematic N/A 1.0 Edge SM-9 35 Systematic N/A 3.9 Edge SM-1 0
-70 Systematic N/A 6.9 Edge SM-11 161 Systematic N/A
- Sample measurements are taken from the lower left or southwest corner of the surface on which they lie.
Plum Brook Reactor Facility FSSR, Attachment 12 Appendix B Rev. 0, Page 143 of 150 Survey Unit RB-4-40 RB -25' - Ceiling Section #7 7*ffgý II rswil is -_W5 I
-1 I""
r RB-4-40 AREA: RB -25' Elevation, Ceiling Section #7 Measurement Locations and results Location /
X Co-ord (m)
Y Co-ord (m) dpm/l 00-cm 2 Type Notes 1.4 1.4 SM-1 643 Systematic N/A 1.3 1.4 SM-2 266 Systematic N/A 0.3 3.6 SM-3 643 Systematic N/A Edge 3.6 SM-4 413 Systematic N/A 2.6 3.6 SM-5 706 Systematic N/A 1.4 5.8 SM-6 853 Systematic N/A 0.2 8.0 SM-7 657 Systematic N/A 0.4 Edge SM-8
-28 Systematic N/A 1.4 0.5 SM-9 203 Systematic N/A 4.8 Edge SM-10
-42 Systematic N/A 5.8 0.5 SM-11 70 Systematic N/A
- Sample measurements are taken from the lower left or southwest corner of the surface on which they lie.
Plum Brook Reactor Facility FSSR, Attachment 12 Appendix B Rev. 0, Page 144 of 150 Survey Unit RB-4-41 RB -25' - Ceiling Section #8
¶
'15-01 wiiL RB-4-41 AREA: RB -25' Elevation, Ceiling Section #8 Measurement Locations and results Location /
X Co-ord (m)
Y Co-ord (m) dpmll 00-cm2 Type Notes 2.2 0.3 SM-1 105 Systematic N/A 4.6 0.3 SM-2 133 Systematic N/A 2.0 Edge SM-3
-531 Systematic N/A 0.3 Edge SM-4 748 Systematic N/A 1.8 0.2 SM-5
-28 Systematic N/A 3.7 0.4 SM-6
-147 Systematic N/A 6.1 0.2 SM-7
-210 Systematic N/A 1.4 0.1 SM-8 140 Systematic N/A 0.3 1.4 SM-9 350 Systematic N/A 0.2 2.2 SM-1 0 503 Systematic N/A 0.3 5.6 SM-1 1 280 Systematic N/A
- Sample measurements are taken from the lower left corner of the surface on which they lie.
Plum Brook Reactor Facility FSSR, Attachment 12 Appendix B Rev. 0, Page 145 of 150 Survey Unit RB-4-42 RB -25' Elevation, Cold Sump
X Co-ord (m)
Y Co-ord (m) dpmn/1 00-cm2 Type Notes 0.1 west of 0.2 south of SM-1 N/A Systematic Not acquired see release 12 o'clock 12 o'clock record body 0.8 0.4 SM-2 541 Systematic N/A 1.8 0.4 SM-3 516 Systematic N/A 2.9 0.4 SM-4 410 Systematic N/A 0.2 1.3 SM-5 377 Systematic N/A 1.3 1.3 SM-6 205 Systematic N/A 2.3 1.3 SM-7 123 Systematic N/A 3.4 1.3 SM-8 262 Systematic N/A 0.8 2.3 SM-9 238 Systematic N/A 1.8 2.3 SM-10 508 Systematic N/A 2.9 2.3 SM-11 66 Systematic N/A Lower left corner or sump is due norm kI-Z o cIocK), for SlVI iocauons 2 mnru I I te A coor inate is measured clockwise from 12 o'clock and the Y co-ordinate is measured up from the sump bottom.
Plum Brook Reactor Facility FSSR, Attachment 12 Appendix B Rev. 0, Page 146 of 150 Survey Unit RB-4-43 RB -25'- PPP Sump RB-4-43 AREA: RB -25' Elevation, PPP Sump Measurement Locations and results Location /
X Co-ord (m)
Y Co-ord (m) dpm/1 00-cm 2 Type Notes 0.6 west of 12 o'clock 1.2 south of 12 o'clock SM-1 2434 Systematic N/A 0.8 east of 12 o'clock 1.2 south of 12 o'clock SM-2 1727 Systematic N/A 0.7 0.9 SM-3 2538 Systematic N/A 2.1 0.9 SM-4 1664 Systematic N/A 3.5 0.9 SM-5 1706 Systematic N/A 4.9 0.9 SM-6 1573 Systematic N/A 6.3 0.9 SM-7 1699 Systematic N/A 1.4 2.2 SM-8 1084 Systematic N/A 2.8 2.2 SM-9 1587 Systematic N/A 4.2 2.2 SM-10 1944 Systematic N/A 5.6 2.2 SM-11 1273 Systematic N/A
- Lower left comer of sump is due north (12 o'clock), for SM locations 3 thru 11 the X coordinate is measured clockwise from 12 o'clock and the Y co-ordinate is measured up from the sump bottom.
Plum Brook Reactor Facility FSSR, Attachment 12 Appendix B Rev. 0, Page 147 of 150 Survey Unit RB-5-1 RB Exterior Walls Eage 1 of 2
Plum Brook Reactor Facility FSSR, Attachment 12 Appendix B Rev. 0, Page 148 of 150 Survey Unit RB-5-1 RB Exterior Walls Page 2 of 2 RB-5-1 AREA: Reactor Building - Exterior Walls Measurement Locations and results Location /
X Co-ord (m)
Y Co-ord (m) dpml/ 00-cm 2 Type Notes 6.6 2.3 SM-1 340 Systematic N/A 1.8 1.0 SM-2
-231 Systematic N/A 12.6 6.6 SM-3 150 Systematic N/A 16.9 2.0 SM-4
-54 Systematic N/A 9.8 7.2 SM-5 95 Systematic N/A 7.0 Edge SM-6
-102 Systematic N/A 45.1 6.2 SM-7 565 Systematic N/A 7.7 3.6 SM-8
-136 Systematic N/A 19.9 0.9 SM-9 184 Systematic N/A 3.4 5.7 SM-10 265 Systematic N/A 2.6 7.3 SM-11 129 Systematic N/A
- Sample measurements are from the lower left corner of the wall surface on which they rest.
Plum Brook Reactor Facility FSSR, Attachment 12 Appendix B Rev. 0, Page 149 of 150 Survey Unit RB-5-2 RB Roof - North Section F
1.
RB-5-2 AREA: Reactor Building Roof - North Section Measurement Locations and results Location I X Co-ord (m)
Y Co-ord (m) dpmll00-cm 2 Type Notes 11
-66 SM-1 378 Systematic N/A 40
-66 SM-2 1547 Systematic N/A 155
-66 SM-3 2149 Systematic N/A 25
-41 SM-4 649 Systematic N/A 140
-41 SM-5 2345 Systematic N/A 11
-16 SM-6 176 Systematic N/A 40
-16 SM-7 1284 Systematic N/A 68
-16 SM-8 757 Systematic N/A 97
-16 SM-9 1872 Systematic N/A 126
-16 SM-10 439 Systematic N/A 155
-16 SM-1 1 1946 Systematic N/A
- Sample measurements are from the Northwest corner of the survey unit.
Plum Brook Reactor Facility FSSR, Attachment 12 Appendix B Rev. 0, Page 150 of 150 Survey Unit RB-5-3 RB Roof - South Section RB-5-3 AREA: Reactor Building Roof - South Section Measurement Locations and results Location I X Co-ord (im)
Y Co-ord (m) dpmll 00-cm 2 Type Notes 15 19 SM-1 601 Systematic N/A 44 19 SM-2 750 Systematic N/A 72 19 SM-3 872 Systematic N/A 100 19 SM-4 372 Systematic N/A 129 19 SM-5 210 Systematic N/A 1
43 SM-6 685 Systematic N/A 30 43 SM-7 791 Systematic N/A 115 43 SM-8 284 Systematic N/A
-13 68 SM-9 1115 Systematic N/A 15 68 SM-1 0 601 Systematic N/A 129 68 SM-11 514 Systematic N/A
- Sample measurements are from the Southwest corner of the survey unit.
Final Status Survey Report 2 Reactor Building Revision 0 Appendix C QC Measurements
Plum Brook Reactor Facility FSSR, Attachment 12 Appendix C, Rev. 0, Page 2 of 4 Measurement Net Activity (1)(2)
QC Replicate (2)
RPD (%)
Survey Unit ID (dpm/l 00-cm 2)
(dpm/100-cm 2)
(3)
RB-4-42 SM-11 66 210 104.3 RB-1-20 SM-5 67 343 134.6 RB-3-38 SM-3 117
-35 370.7 RB-4-28 SM-5 133 58 78.5 RB-3-38 SM-4 139 0
200.0 RB-3-1 SM-9 146 21 149.7 RB-4-28 SM-7 167 230 31.7 RB-5-1 SM-9 184 41 127.1 RB-3-7 SM-6 252 347 31.7 RB-1-40 SM-1 263 777 98.8 RB-1-40 SM-4 263 236 10.8 RB-3-16 SM-10 263 107 84.3 RB-1-20 SM-2 315 357 12.5 RB-1-40 SM-6 336 338 0.6 RB-3-23 SM-9 353 613 53.8 RB-3-29 SM-12 425 527 21.4 RB-4-34 SM-2 441 346 24.1 RB-1-9 SM-8 444 777 54.5 RB-3-34 SM-8 451 446 1.1 RB-3-6 SM-6 462 733 45.4 RB-1-24 SM-5 477 419 12.9 RB-3-33 SM-7 497 853 52.7 RB-4-21 SM-4 497 540 8.3 RB-1-22 SM-1 503 203 85.0 RB-3-34 SM-9 503 655 26.3 RB-4-22 SM-9 503 373 29.7 RB-4-42 SM-10 508 273 60.2 RB-3-4 SM-11 510 693 30.4 RB-1-7 SM-2 516 642 21.8 RB-3-27 SM-2 529 127 122.6 RB-3-33 SM-6 542 259 70.7 RB-1-20 SM-7 544 351 43.1 RB-1-8 SM-1 549 405 30.2 RB-4-34 SM-3 552 477 14.6 RB-2-2 SM-2 555 927 50.2 RB-4-15 SM-9 562 697 21.4 RB-1-36 SM-5 582 662 12.9 RB-1-24 SM-7 604 622 2.9 RB-3-18 SM-5 606 20 187.2 RB-3-18 SM-4 613 113 137.7
Plum Brook Reactor Facility FSSR, Attachment 12 Appendix C, Rev. 0, Page 3 of 4 Measurement Net Activity (1)(2)
QC Replicate (2) RPD (%)
Survey Unit ID (dpm/100-cm 2)
(dpm/100-cm 2)
(3)
RB-3-19 SM-1 613 527 15.1 RB-4-15 SM-5 613 474 25.6 RB-1-36 SM-1 614 574 6.7 RB-4-21 SM-2 622 576 7.7 RB-2-1 SM-9 628 967 42.5 RB-4-10 SM-3 629 380 49.4 RB-1-20 SM-11 631 587 7.2 RB-3-29 SM-11 634 787 21.5 RB-1-9 SM-4 647 622 3.9 RB-4-33 SM-3 662 643 2.9 RB-1-20 SM-10 678 392 53.5 RB-4-5 SM-5 680 529 25.0 RB-4-22 SM-7 706 620 13.0 RB-4-40 SM-5 706 633 10.9 RB-4-11 SM-1 734 633 14.8 RB-4-5 SM-3 740 484 41.8 RB-1-22 SM-6 752 480 44.2 RB-4-33 SM-6 755 308 84.1 RB-1-24 SM-3 758 439 53.3 RB-3-29 SM-7 765 633 18.9 RB-3-19 SM-9 768 647 17.1 RB-3-23 SM-5 797 933 15.7 RB-1-9 SM-5 824 432 62.4 RB-1-7 SM-7 830 311 91.0 RB-4-8 SM-1 839 207 120.8 RB-3-5 SM-2 846 860 1.6 RB-4-40 SM-6 853 587 36.9 RB-4-24 SM-2 869 447 64.1 RB-1-22 SM-3 913 770 17.0 RB-4-15 SM-7 927 730 23.8 RB-4-15 SM-11 949 1007 5.9 RB-4-5 SM-1 980 850 14.2 RB-1-36 SM-10 987 291 108.9 RB-3-5 SM-10 993 613 47.3 RB-4-5 SM-7 993 706 33.8 RB-1-8 SM-9 1,039 439 81.2 RB-1-7 SM-3 1,092 358 101.2 RB-4-20 SM-11 1,420
-438 378.4 RB-5-2 SM-3 2,149 597 113.0 RB-5-2 SM-5 2,345 523 127.1 RB-4-43 SM-1 2,434 2,013 18.9
Plum Brook Reactor Facility FSSR, Attachment 12 Appendix C, Rev. 0, Page 4 of 4 Measurement Net Activity (1)(2)
QC Replicate (2) RPD (%)
Survey Unit ID (dpm/100-cm 2)
(dpm/100-cm 2)
(3)
RB-4-18 SM-2 3,920 3,460 12.5 RB-4-18 IM-9 8,470 9,140 7.6 RB-4-42 IM-1 9,000 10,292 13.4 RB-3-4 IM-1 19,100 18,420 3.6 RB-4-18 IM-12 22,500 24,300 7.7 RB-4-18 IM-11 22,800 24,000 5.1 RB-4-3 IM-3 30,800 29,000 6.0 RB-4-3 IM-2 37,500 42,600 12.7 RB-3-13 IM-2 45,000 47,100 4.6 Appendix C Notes:
- 1. The table entries are sorted by Net Activity in increasing order.
- 2. Repeat replicate QC measurements performed where RPD criterion not met are not included.
- 3. Relative Percent Difference (RPD) is calculated as:
RPD =
(Original - Re plicate)
(Original + Re plicate)" 2
Plum Brook Reactor Facility Final Status Survey Report 2 Reactor Building Revision 0 Appendix D Evaluation of Revised DCGLs
Plum Brook Reactor Facility FSSR, Attachment 12 Appendix D, Rev. 0, Page 2 of 11 TABLE of CONTENTS 1.0 Introdu ction............................................................................................................................
3 2.0 R evised D C G L s..............................................................................................................
4 3.0 Survey Design Calculations with Revised DCGLs...........................................................
4 4.0 Instrum ent Sensitivities and Action Levels.......................................................................
6 5.0 Comparison of Investigative Measurements with Revised DCGLs...................................
9 6.0 Evaluation of FSS Results to Ensure the Dose Criterion is met.......................................
10 Addendum 1 - VSP Design Screens Addendum 2 - Calculation of Revised Equivalent Screening Level DCGL for ALARA Evaluation LIST of TABLES Table 1, DCGLs for the RB Structures - Comparison of Revised and Original Values.................
4 Table 2, RB Survey Design Recalculation Summary.......................................................................
5 Table 3, Revised DCGLEMC Values for RB Class 1 Survey Units...................................................
6 Table 4, LMI 44-116 Detector Scan Sensitivity and Investigation Levels for Original and Revised DCGLs - Class 1 Areas...........................................................................................
.......... 7 Table 5, LMI 44-9 Detector Scan Sensitivity and Investigation Levels for Original and Revised D CG Ls-Class 1 Areas..............................................................................................
......... 7 Table 6, LMI 44-116 Action Levels and Scan Capabilities for Class 2 and 3 Survey Units........... 8 Table 7, Comparison of RB Investigative Static Measurements to Revised DCGLs.......................
9 Table 8, Revised EM C and EM C Calculations.............................................................................
10 LIST of FIGURES Figure 1, VSP Screen for Design 43, Survey Unit RB-4-1.......................................................
Al -1 Figure 2, VSP Screen for Design 59, Survey Unit RB-2-1............................................................
Al-2 Figure 3, VSP Design Screen for Design 60A, Survey Unit RB-4-12.......................................
A1-3 Figure 4, VSP Design Screen for Design 61A, Survey Unit RB-3-14...........................................
Al-4 Figure 5, VSP Design Screen for Design 66, Survey Unit RB-1-1................................................
Al-5 Figure 6, VSP Design Screen for Design 69B, Survey Unit RB-5-3.............................................
Al-6 Figure 7, VSP Design Screen for Design 70A, Survey Unit RB-3-1.........................................
A1-7
Plum Brook Reactor Facility FSSR, Attachment 12 Appendix D, Rev. 0, Page 3 of 11 1.0 Introduction As part of an NRC inspection at the PBRF Decommissioning Project in July 2011, radiological surveys and records review were performed by the NRC independent verification contractor, ORISE. The ORISE review included a review of gross beta activity DCGL values used by the PBRF to evaluate FSS measurements for compliance with the 25 mrem/y release criterion. The gross beta activity DCGL values and the radionuclide mixtures used to calculate them are published in a PBRF Technical Basis Document, PBRF-TBD-07-001 [PBRF 2007].
The ORISE report, issued in October 2011, identified an error in the gross activity DCGL used for the -15 ft. elevation (Area 20) of the Reactor Building, 35,296 dpm/100-cm 2. The ORISE report determined that this value did not correctly account for the use of beta surface activity measurements as surrogates in areas such as the Reactor Building -15 ft. elevation where the radionuclide mixture reported in TBD-07-001 included alpha emitting U-234 [ORISE 2011].
In subsequent discussions with the NRC, it was agreed that NASA would re-evaluate the method used to calculate DCGLs, with particular attention given to areas where uranium was included in the radionuclide mixture. This evaluation would also include a review of the basis for determining that uranium was present in the radionuclide mixtures. The results of this re-evaluation, including revised radionuclide mixtures and revised gross activity DCGLs for the PBRF structures, are published in a new technical basis document, [PBRF 2012a]. In what follows, effects of the revised gross activity DCGLs on the FSS of the Reactor Building (RB) are evaluated. The following topics are addressed:
- The effect of revised DCGLs on the survey design calculation of the number of measurements, "N".
- Instrument sensitivities and scan survey action levels relative to the revised DCGLs.
" Evaluation of FSS systematic measurement results against the revised DCGLs to ensure that the RB survey units satisfy the 25 mrem/y criterion.
- Investigative static measurements are reviewed to determine if Elevated Measurement Comparison (EMC) and Elevated Measurement Test (EMT) results are changed as a result of reduced DCGLs.
The next section, Section 2.0, contains a summary of the revised gross activity DCGLs. In Section 3.0, an evaluation to determine if the number of systematic measurements, N, is changed as a result of the revised DCGLs is described. Section 4.0 summarizes an evaluation of instrument sensitivities and scan survey action levels to ensure that FSS Plan requirements for action levels relative to DCGLs are satisfied. In Section 5.0, the FSS systematic total surface beta measurement results are evaluated to demonstrate that the RB survey units meet the 25 mrem/y criterion, considering the revised DCGLs. Static investigative measurement results are compared to the revised DCGLs in Section 6.0. Addendum 1 provides the Visual Sample Plan output screens for design calculations using the revised DCGLs and Addendum 2 presents the EXCEL template used in the revised ALARA evaluation.
Plum Brook Reactor Facility FSSR, Attachment 12 Appendix D, Rev. 0, Page 4 of 11 2.0 Revised DCGLs The revised gross beta activity DCGLs for RB structural areas are compared to the original DCGLs in Table 1. It is seen that there are only five DCGL values used in the 13 RB designs. In the discussions which follow, Designs 43, 59, 60A, 61A, 66, 69B and 70A will be examined to determine if the revised DCGLs affect the design calculations.
Table 1, DCGLs for the RB Structures - Comparison of Revised and Original Values TBD-07-001 Survey Table 5-3 DCGLR B % change Design Location DCGLGB (dpm/1 00-cm 2) 43 Canals F, G, H RB-4-1 thru RB-4-11 31,711 30,734
-3.1 Area 11 Mezzanine 29,060 28,040
-3.5 RB-2-1 & RB-2-2 2,62800 60A
-25 ft. FL. & Trenches 14,600 14,382
-1.5 RB-4-12 thru RB-4-20 60B
-25 ft. Walls & Ceiling RB-4-21 thru RB-4-41 14,600 14,382
-1.5 61A
-15 ft. Floor, RB-3-3 thru RB-3-14 & RB 3-23 35,296 40,500 14.7 61B
-15 ft. Walls & Ceiling 35,296 40,500 14.7 RB-3-15 thru RB-3-22 & RB3-24 thru ERB-3-39 61C
-15 ft. E. Stairway resurvey, RB-3-13 35,296 40,500 14.7 0 ft. upper walls & ceil.
65 RB-I-17 thru RB-1-21, RB-1-28 thru RB-1-30 &
29,060 28,040
-3.5 RB-1-37 thru RB-1-42 0 ft. Fl. & L.W.
66 RB-I-1 thru RB-1-16, 29,060 28,040
-3.5 RB-1-22 thru RB-1-27, RB-1-31 thru RB-1-42 69A Exterior Walls, RB-5-1 (Default) 27,166 23,146
-14.8 69B Roof, RB-5-2, RB-5-3 (Default) 27,166 23,146
-14.8 70A Cold Sump -15 ft. RB-3-1 35,296 40,500 14.7 70C
-25 ft. Cold Sump & PPP Rm. Sump RB-4-42, 14,600 14,382
-1.5 RB-4-43 3.0 Survey Design Calculations with Revised DCGLs To determine if the revised DCGLs would result in significant additional FSS measurements, the number of measurements was recalculated for the seven RB survey designs which have distinct design parameters. The revised DCGLs were input into VSP. The principal design parameters and the VSP input parameter values are shown in Table 2. The table lists the original design parameters for Designs 43, 59, 60A, 61A, 66, 69B and 70A. The table rows immediately below the original design parameters show the design parameters associated with the revised DCGLs. Comparing the original and revised design parameter values, it is seen that the LBGR/DCGL ratio is preserved as is the value of a, except where a was assumed to be a fixed percentage of the DCGL (20%). The LBGR did change somewhat, because of the change in DCGL values, but the FSS Plan guidance to maintain the relative shift (A/a) between one and three was accomplished in all but Design 61A
Plum Brook Reactor Facility FSSR, Attachment 12 Appendix D, Rev. 0, Page 5 of 11 where the value of A/a changed from 3.0 to 3.4. Figures 1 through 7 in Addendum 1 are images of the VSP design output screens for the re-calculation of N. They show the values of a, the Type I error probability, P, the Type II error probability (these are unchanged), A, the DCGL and a, the estimated standard deviation.
Table 2 shows that the calculated number of measurements for all the designs is unchanged. This attests to the conservative assumptions used in the original design calculations.
Table 2, RB Survey Design Recalculation Summary Design Area DCGLw LBGR LBGR A (1) a A/a N
No.
(1)
(I)
DCGLw Canals F, G, H (2) 27,271 24,166 0.89 3,105 1,035 3.0 11 Canals F, G, H, I Revised (2) 26,431 23,422 0.89 3,009 1,035 2.9 11 Area 11 Mezzanine (3) 26,154 25,077 0.96 359 359 3.0 15 59 Area 11 Mezzanine, Revised (3) 25,236 24,197 0.96 359 359 2.9 15
-25 ft. Floor &
60A Trenches (2) 12,556 6,278 0.5 6,278 2,260 2.8 11
-25 fTrenches, Revised (2) 12,369 6,184 0.5 6,184 2,260 2.7 11 61A
-15 Floor (2) 30,355 26,758 0.88 3,597 1,199 3.0 11
-15 Floor, Revised (2 )
34,830 30,703 0.88 4,127 1,199 3.4 11 0 ft. Floor & Lower 66 Walls (3) 26,154 13,077 0.5 13,077 5,230 2.5 11 0 ft. Floor & Lower Walls, Revised (3) 25,236 12,618 0.5 12,618 5,230 2.4 11 Exterior Roof (3) 24,449 12,225 0.5 12,224 4,890 2.5 11 69B Exterior Roof, 20,831 10,416 0.5 10,415 4,166 2.5 11 Revised '3) (4) 11 4,
166 2.5 11 Cold Sump, -15 ft. (3) 70A
ý Cold Sump, -15 ft.,
Revised (3)(4)
Table 2 Notes:
- 1. Units are dpm/100-cm 2.
- 2. The DCGLw values are obtained by adjusting the DCGLs published in TBD-07 -001 and TBD-11-002 (revised DCGLs) to account for dose contributions from insignificant radionuclides (2.5 mrem) and embedded piping (1.0 mrem).
- 3. The DCGLw values are obtained by adjusting the DCGLs published in TBD-07-001 and TBD-1 1-002 (revised DCGLs) to account for dose contributions from insignificant radionuclides (2.5 mrem). No adjustment is made for embedded piping.
- 4. The standard deviations for the revised 69B and 70A designs are changed to maintain the original assumption that a = 20% of the DCGL.
Plum Brook Reactor Facility FSSR, Attachment 12 Appendix D, Rev. 0, Page 6 of 11 4.0 Instrument Sensitivities and Action Levels Sensitivities of instruments used in the FSS of the RB are reviewed to ensure that they were sufficient to meet FSS Plan requirements in view of the revised DCGLs. As described in Section 4.1 of the main body of this report, the FSS Plan requirement for Class 1 survey units is that when an observed scan count rate is greater than a value equivalent to the DCGLEMC, an investigation is required. For Class 2 and 3 survey units, an investigation is required whenever a scan count rate is observed that is greater than a value equivalent to the DCGLw. Alternatively, if the scan MDC is greater than the DCGLw, an observed scan count rate greater than the scan MDC requires an investigation.
In the original survey designs and instructions for Class 1 survey units, scan investigation levels were set below the DCGL. This provided a conservative margin below the requirement that the investigation level be set at the DCGLEMC. The investigation levels used in the FSS of the RB are compared to DCGLEMC values associated with the revised DCGLs to determine if the FSS Plan requirement is satisfied in retrospect. Table 3 lists the revised DCGLEMC values for the designs where the revised DCGLws are decreased from the original values.
Table 3, Revised DCGLEMC Values for RB Class 1 Survey Units Revised Revised Area of Area RCGLsed Design Reactor Building Area DCGLw Largest AEMC Factor D
No.(dpm/100-cm
- 2)
SU (M2)
()
(2)
(dpm/100-cm2)
(3) 43 Canals F, G & H 26,431 97.8 8.9 2.2 58,148
-25 ft. Floor, Trenches, 12,369 94.2 8.6 2.2 27,212 60A/60B Walls & Ceiling 139.6271 66 0 ft. Floor & Lower 25,236 97 8.8 2.2 Walls 55,519 Table 3 Notes:
- 1. Calculated as AEMC = 100/N where 100 in 2 is a conservative-representative value of the Class 1 RB survey unit areas.
- 2. The Area Factor for AEMC = 9.1 is 2.2. It is obtained by interpolation from FSS Plan Table 3-5, Building Reuse Area Factors (Structures).
- 3. The revised DCGLEMC is obtained as revised DCGL x 2.2.
Next, the investigation levels established in survey designs for the instrument models used in the RB FSS of Class 1 survey units are compared to the Revised DCGLEMCS for those survey designs where the revised DCGLs are decreased from the original TBD-07-001 values. Table 4 shows the LMI model 44-116 detector information. The LMI 44-9 detector information is shown in Table 5. The tables show that in all cases instrument scan sensitivities are sufficient to meet the investigation level requirement for Class 1 areas; the detectors are capable of detecting contamination levels at or below the DCGLEMC for the revised DCGLs.
Plum Brook Reactor Facility FSSR, Attachment 12 Appendix D, Rev. 0, Page 7 of 11 Table 4, LMI 44-116 Detector Scan Sensitivity and Investigation Levels for Original and Revised DCGLs - Class 1 Areas SR Scan Scan count Scan count Scan count rate Investigation Investigation Design Reactor Buli A
Scan MDC Investigation rate = DCGL rate = revised
= revised Level <
Level <
No.
Level (1 (2)
DCGL (2)
DCGLEMC (2)
Revised Revised (dpm/1 00-cm 2)
(gcpm)
(ncpm)
DCGL DCGLEMc 43 Canals F, G & H 2587 (3) 3188 (3) 3188 (3) 3089 6797 No Yes 60A/60B
-25 ft. Floor, Trenches, 2892 (4) 1400 (5) 1468 (4) 1446 3181 No Yes Walls & Ceiling 66 0 ft. Floor & Lower Walls 2892 (6) 3057 (7) 3057 (6) 2950 6489 No Yes Table 4 Notes:
- 1. The scan investigation level for the 44-116 is in units of gcpm.
- 2. Action levels corresponding to DCGLs are in ncpm. Typical 44-116 background count rates are 200 to 250 cpm.
- 3. From Design 43, Table 5 and SR-3 16 Instructions. These values are for detector-to-surface distance < 1/2/ in. & scan speed of 15.2 cm/sec.
- 4. From Design 60A, Table 5. These values are for detector-to-surface distance < 1/22 in. & scan speed of 15.2 cm/sec.
- 5. From SR-306, survey instructions.
- 6. From Design 66, Table 4. These values are for detector-to-surface distance < V2 in. & scan speed of 15.2 cm/sec.
- 7. From SR-327, survey instructions.
Table 5, LMI 44-9 Detector Scan Sensitivity and Investigation Levels for Original and Revised DCGLs - Class 1 Areas SR Scan Scan count Scan count Scan count rate Investigation Investigation Design Reactor Building A Scan MDC Investigation rate = DCGL rate = revised
= revised Level <
Level <
No.
Level (1)
DCGL (
DCGLEMC (
Revised Revised (dpm/100-cm2 )
(ncpm)
DCGL DCGLEMC 43 Canals F, G & H 11268 (2) 409 (2) 409 (2) 450 991 Yes Yes 60A/60B
-25 ft. Floor, Trenches, 10025 (3) 200 (4) 212 (3) 211 464 Yes Yes Walls & Ceiling 66 0 ft. Floor & Lower Walls 11268 (5) 392 (6) 392 (5) 430 946 Yes Yes Table 5 Notes:
- 1. Action levels corresponding to DCGLs are in ncpm. Typical 44-9 background count rates are 50 to 100 cpm.
- 2. From Design 43, Table 5 and SR-316 Instructions. These values are for detector-to-surface distance on contact & scan speed of 4.4 cm/sec.
- 3. From Design 60A, Table 5. These values are for detector-to-surface distance on contact & scan speed of 4.4 cm/sec.
- 4. From SR-306, survey instructions.
- 5. From Design 66, Table 4. These values are for detector-to-surface distance on contact & scan speed of 4.4 cm/sec.
- 6. From SR-327, survey instructions.
Plum Brook Reactor Facility FSSR, Attachment 12 Appendix D, Rev. 0, Page 8 of 11 To evaluate the effect of revised-reduced DCGLs on the Class 2 and Class 3 survey units in the FSS of the RB, the scan survey data was reviewed to determine the measurement capabilities of the detectors actually used in the surveys. Table 6 summarizes the results. It shows that in the actual surveys of the Class 2 survey units and the single Class 3 survey unit, scan sensitivities were well below the DCGL (the revised DCGLw for these survey units is 25,236 dpm/100-cm 2, with adjustment for deselected radionuclides). In these surveys, conservative action levels were used which corresponded to observed scan conditions; rough and fractured surfaces with detector-to-surface effective distance greater than the distance assumed under optimal conditions. Also, in calculating the total surface activity equivalent to the action level,; the detector background count rate is subtracted; in contrast with normal practice in the FSS.
Table 6, LMI 44-116 Action Levels and Scan Capabilities for Class 2 and 3 Survey Units Survey Action Level Detector Detector Efficiency Total Surface Activity Unit used in Survey
Background
Efficiency Correction Equivalent to Action Level (AL, gcpm) (1) (bkg, cpm)
(Ei) (2)
Factor (EJ) (TSA, dpm/100-cm 2) (4)
(3)
RB-1-17 1400 162 0.359 0.3966 17,390 RB-1-18 1500 194 0.359 0.3966 18,345 RB-1-19 1000 163 0.359 0.3966 11,757 RB-1-20 1000 173 0.364 0.3966 11,457 RB-1-21 1000 220 0.302 0.3966 13,025 RB-1-28 1000 185 0.364 0.3966 11,291 RB-1-29 200 (5) 33 0.145 1.0 19,195 RB-1-30 1000 204 0.362 0.3966 11,089 RB-1-43 1000 182 0.359 0.3966 11,490 RB-2-1 1500 182 0.333 0.5427 14,586 RB-2-2 3000 (6) 807 0.401 1.0 10,938 RB-5-2 1300 256 0.346 0.668 8,761 RB-5-3 1000 244 0.349 0.688 6,290 RB-5-1 171 600 190 0.359 0.5427 4,209 Table 6 Notes:
- 1. Scan action levels applied by technicians to the survey.
- 2. These are the actual efficiencies reported for the detectors used in the survey. A generic surface efficiency, E, = 0.5 is also applied.
- 3. This is an additional efficiency correction factor used to account for the reduced efficiency due to the increased effective detector-to-surface distance (44-116 detector). An E, of 0.8349 corresponds to 0.5 in. distance; an E, of 0.688 corresponds to 1.0 in distance; an E, corresponds to 1.5 in distance and an E, of 0.3966 corresponds to 2.0 in.
AL - bkg
- 4. The Total surface beta activity equivalent to the action level is calculated as: TSA ='
E5 *0.5*EA
- 5. A 44-9 detector was used.
- 6. A 43-37 detector was used.
- 7. Class 3 survey unit.
Plum Brook Reactor Facility FSSR, Attachment 12 Appendix D, Rev. 0, Page 9 of 11 5.0 Comparison of Investigative Measurements with Revised DCGLs The Investigative static measurements are summarized in Table 13 of the Reactor Building FSS Report. In Table 7 below, the investigative static measurement results are compared to the revised DCGLs.
Table 7, Comparison of RB Investigative Static Measurements to Revised DCGLs Size of Static Survey Measurement Elevated Measurement Original Revised Orig.
Rev.
Unit ID Area (dpm/n100-DCGLw DCGLw (cm2) cm2)
DCGLw DCGLw RB-3-4 IM-1 100 19,100 30355 34830 No No RB-3-13 IM-1 100 33,700 30355 34830 Yes No RB-3-13 IM-2 100 45,000 30355 34830 Yes Yes RB-4-3 IM-1 100 15,060 27271 26431 No No RB-4-3 IM-2 100 37,500 27271 26431 Yes Yes RB-4-3 IM-3 100 14,600 27271 26431 No No RB-4-4 IM-1 1000 22,800 27271 26431 No No RB-4-4 IM-2 700 19,200 27271 26431 No No RB-4-12 IM-1 100 20,200 12556 12369 Yes Yes RB-4-12 IM-2 100 41,100 12556 12369 Yes Yes RB-4-12 IM-3 100 16,600 12556 12369 Yes Yes RB-4-13 IM-1 100 9,250 12556 12369 No No RB-4-13 IM-2 100 10,100 12556 12369 No No RB-4-18 IM-I 100 7,460 12556 12369 No No RB-4-18 IM-2 100 13,600 12556 12369 Yes Yes RB-4-18 IM-3 100 10,400 12556 12369 No No RB-4-18 IM-4 100 10,900 12556 12369 No No RB-4-18 IM-5 100 11,700 12556 12369 No No RB-4-18 IM-6 100 10,200 12556 12369 No No RB-4-18 IM-7 100 4,920 12556 12369 No No RB-4-18 IM-8 100 12,000 12556 12369 No No RB-4-18 IM-9 100 8,470 12556 12369 No No RB-4-18 IM-10 200 7,800 12556 12369 No No RB-4-18 IM-11 100 22,800 12556 12369 Yes Yes RB-4-18 IM-12 1550 22,500 12556 12369 Yes Yes RB-4-19 IM-1 100 23,523 12556 12369 Yes Yes RB-4-20 IM-1 100 11,500 12556 12369 No No RB-4-20 IM-2 100 14,400 12556 12369 Yes Yes RB-4-20 IM-3 100 12,800 12556 12369 Yes Yes RB-4-20 IM-4 100 5,850 12556 12369 No No RB-4-20 IM-5 100 7,990 12556 12369 No No
Plum Brook Reactor Facility FSSR, Attachment 12 Appendix D, Rev. 0, Page 10 of 11 Inspection of Table 7 reveals that as expected, in all cases where the revised DCGL is decreased and the investigative measurement exceeded the original DCGL, it exceeded the revised DCGL as well.
The EMC and EMT are re-calculated to ensure that the results are unchanged. The results of these calculations are shown in Table 8. Comparison of Table 8 results with Table 14 in the main report shows that in all cases where the DCGLw is reduced, the investigative measurements are still well below the DCGLEMC values. The table shows that the calculated EMT unity values are all increased (except for the RB-13 measurements), but only slightly. The highest unity value is only 25% of unity. The Table 8 results show that the impacts of the revised DCGLs on the EMC and EMT are very small and do not change any conclusions from the original tests; all are still satisfactory.
Table 8, Revised EMC and EMC Calculations Size of Measured Calculated Average EMT Survey Measurement Elevated Activity DCGLW DCGLEM Activity in Unity Unit ID Area (cm)
SU Value (dprn/1 00-cm 2)
RB-3-13 IM-1/EMA-I 100 33,700 34,830 ()
1.400E+06 4.835E+02 0.069 RB-3-13 IM-2/EMA-2 100 45,000 34,830 )
1.400E+06 4.835E+02 0.069 RB-4-3 IM-2/EMA-1 100 37,500 26,431 1.063E+06 5.778E+02 0.057 RB-4-12 IM-1/EMA-1 100 20,200 12,369 4.972E+05 8.181E+02 0.218 RB-4-12 IM-2/EMA-2 100 41,100 12,369 4.972E+05 8.181E+02 0.218 RB-4-12 IM-3/EMA-3 100 16,600 12,369 4.972E+05 8.181E+02 0.218 RB-4-18 IM-2/EMA-1 100 13,600 12,369 4.972E+05 1.109E+03 0.201 RB-4-18 IM-lI/EMA-100 22,800 12,369 4.972E+05 1.109E+03 0.201 2
RB-4-18 IM-12/EMA-1550 22,500 12,369 4.972E+05 1.109E+03 0.201 2
RB-4-19 IM-l/EMA-1 100 23,523 12,369 4.972E+05 2.572E+03 0.250 RB-4-20 IM-2/EMA-1 100 14,400 12,369 4.972E+05 9.608E+02 0.129 RB-4-20 IM-3/EMA-2 100 12,800 12,369 4.972E+05 9.608E+02 0.129 Table 8 Note:
- 1. The DCGLw for the RB-3-13 measurements represents an increase and thus will have no impact on the conclusions of the EMC and EMT. The results are included for completeness.
6.0 Evaluation of FSS Results to Ensure the Dose Criterion is met Results of the systematic fixed survey measurements from each survey unit are reviewed to ensure that they satisfy the 25 mrem/y criterion, considering the revised DCGLs. To this end, the results of fixed measurements and tests, reported in Table 12 of the main body of this report are examined.
Table 12 shows that the maximum individual measurement, 5,458 dpm/100-cm 2 (in survey unit RB-4-19) is well below the applicable revised DCGLw, 12,369 dpm/100-cm 2. The maximum of the survey unit averages, 2,572 dpm/100-cm 2 (also in survey unit RB-4-19) is also well below the applicable revised DCGLw, 12,369 dpm/100-cm 2.
The ALARA evaluation in Section 5.6 of the main report is also reviewed to examine the effect of revised DCGLs. Table 18 in the main report shows the screening level DCGL values and the PBRF
Plum Brook Reactor Facility FSSR, Attachment 12 Appendix D, Rev. 0, Page 11 of 11 radionuclide activity fractions used in the ALARA evaluation (RB -25 ft. PPP Room mixture).
Replacing the Table 18 activity fractions with the revised activity fractions developed in the TBD-11-002 for the radionuclide mixture results in a change in the screening level equivalent gross activity DCGL from 2,355 to 8,378 dpm/100-cm 2. The details of this calculation are shown in Addendum 2. This change is primarily due to the removal of U-234 and U-235 from the mixture.
The average of the RB systematic total surface beta activity measurements (451 +/- 480, with an upper 95 th % confidence limit of 476 dpmr/100-cm 2) is well below the revised equivalent screening level DCGL. The conclusion that the ALARA requirement is satisfied is unchanged by the revised DCGLs.
Plum Brook Reactor Facility FSSR, Attachment 12 Appendix D Addendum 1, Rev. 0, Page 1 of 7 Addendum 1 - VSP Design Screens Figure 1, VSP Screen for Design 43, Survey Unit RB-4-1
Plum Brook Reactor Facility FSSR, Attachment 12 Appendix D Addendum 1, Rev. 0, Page 2 of 7 Figure 2, VSP Screen for Design 59, Survey Unit RB-2-1
Plum Brook Reactor Facility FSSR, Attachment 12 Appendix D Addendum 1, Rev. 0, Page 3 of 7 Figure 3, VSP Design Screen for Design 60A, Survey Unit RB-4-12
Plum Brook Reactor Facility FSSR, Attachment 12 Appendix D Addendum 1, Rev. 0, Page 4 of 7 Figure 4, VSP Design Screen for Design 61A, Survey Unit RB-3-14
~3O
Plum Brook Reactor Facility FSSR, Attachment 12 Appendix D Addendum 1, Rev. 0, Page 5 of 7 Figure 5, VSP Design Screen for Design 66, Survey Unit RB-I-1
Plum Brook Reactor Facility FSSR, Attachment 12 Appendix D Addendum 1, Rev. 0, Page 6 of 7 Figure 6, VSP Design Screen for Design 69B, Survey Unit RB-5-3 16C
Plum Brook Reactor Facility FSSR, Attachment 12 Appendix D Addendum 1, Rev. 0, Page 7 of 7 Figure 7, VSP Design Screen for Design 70A, Survey Unit RB-3-1
Plum Brook Reactor Facility FSSR, Attachment 12 Appendix D Addendum 2, Rev. 0, Page 1 of 1 Addendum 2 - Calculation of Revised Equivalent Screening Level DCGL for ALARA Evaluation The EXCEL template used to calculate screening level equivalent gross activity DCGLs for the ALARA evaluation described in Section 5.6 of the main body of this report is shown below. The individual radionuclide screening level DCGLs shown in the range B4:14 are the NRC screening level DCGLs shown in Table 12 of the main body of this report. The template uses the surrogate and gross beta activity DCGL equations from Section 3.6 of the PBRF FSS Plan. These equations are implemented in the cell formulas in the range L8:M9. Example cell formulas are shown for cells L8 and M8. The template calculates screening level equivalent DCGLs for the original and revised radionuclide mixtures.
A B
C D
E F
G H
i K
L M
1-2 3
4_
5 Screening Level DCGLs (dpm/ 100-=m)
=Co-60 Sr-90 1-129 Cs-137 Eu-154 U-234 U-235 1.20E-+08 7,100 8,700 35,000 28,000 12,000 91 98 Screening Screening Activity Fractions Detectable Level Level Description Activity DCGL.i DCGLoB Fraction 7
H-3 Co-60 Sr-90 1-129 Cs-137 Eu-154 U-234 U-235 (dpm/l00-cm2)
-25 ft. PPP Rm.
0.0729 0.5389 0.2222 0
0.1205 0.0171 0.0242 0.0042 0.8987 385 2161 8
Mmb.
Revised -25 f 0.075 0.555 0.229 0
0.124 0.018 0.9251 27996 8378 9 PPP RmL Mix LU-Li_
12 Example Cell Formulas L3 Cell Formula Conmena L4 KS
=(C8+DS+FS+G8)/SUM(BS:l)
Detectable Activt Fraction 15 LB
=1/((4/$F$4)+(B8/F8)/$WB)+((E8/F8)/"4)+((H./F8)/$H$4)+((IS/F8)/$*$4))
Surrogate DCGL Calculation 16 M8
=KB/((F8/LB)+(C5/$C$4)+(D8/$D$4)+(G8/$G$4))
Gross Activity DCGL Calculation