ASME Sec. XI Code Category Unit I Risk Ranking Tables Note: Underlined welds are selected per RIISI. Bold & Italicized print indicates weld has been examined previously.

Risk Characterization F

Failure Potential LC Sketch Syte Co-nse------c -----

uence---------iSiesmin Welds in Segment iWeld~

o ni~

e Segment I Cateory I Rank ID RankI Rank No(s).

Red = New Green = weld Blue = Weld Magenta =

2003 weld since replaced (like.

always Administrati Addenda last for-like) existed but ve change Inclustion Interval was not or RIISI counted in assessment original RIISI change assessment Page 101

ASME Sec. XI Code Category Unit 2 Risk Ranking Tables Note: Underlined welds are selected per RIISI. Bold & Italicized print indicates weld has been examined previously.

System Risk Characterization Consequence Failure Potential Lines in Weld Sketch Segment Category I Rank ID Rank DMs I Rank Segment Count No(s).

1RCS RCS-027 2

High 2-RCS06 High TASCS, TT Medium

  • -16-14 WIB-432 1

1.4-2 1RCS RCS-045 2

High 2-RCS13 High TASCS, TT Medium

  • -16-14 WIB-433, WIB-433A, WIB-433B, WIB-8 1.4-5 433C, WIB-434, WIB-435, WIB-436, Elbow Between WIB-436 and WIB-437 (does not count as a weld), WIB-437 1RCS RCS-049 2

High 2-RCS14B High TASCS Medium S6-15-4 WIB-341, WIB-342, WIB-343, WIB-4 1.4-26 344 1RCS RCS-079 2

High 2-SI05B High TASCS Medium S6-109-14 WIB-245, WIB-246, WIB-247, WlB-6 1.4-10 248, WIB-249, WIB-250 1RCS RCS-006 2

High 2-RCS01 High TT Medium S6-1991-1-1/2 WIB-507 1

1.4-1 1RCS RCS-013 2

High 2-RCS02 High UT Medium S6-1992-1-112 WIB-560 1

1.4-2 1RCS RCS-017 2

High 2-RCS03 High TT Medium S6-50-3 WIB-183 1

1.4-3 1RCS RCS-018 2

High 2-RCS03 High TT Medium S6-1993-1-1/2 WIB-654 1

1.4-3 1RCS RCS-022 2

High 2-RCS04 High UT Medium S6-246-3 WIB-310 1

1.4-4 1RCS RCS-023 2

High 2-RCS04 High UT Medium S6-1994-1-1/2 WIB-732 1

1.4-4 1RCS RCS-046 2

High 2-RCS13 High TT Medium

  • -16-14 WIB-438 (OL), W/B-439(SE)(OL) 2 1.4-5 1RCS RCS-057 2

High 2-RCS17A High TT Medium S6-1171-3 WIB-411 1

1.4-34 1 RCS RCS-059 2

High 2-RCS17B High TU Medium S6-1172-3 WIB-404 1

1.4-35 1RCS RCS-061 2

High 2-RCS17C High TT Medium S6-1195-3 WIB-422 1

1.4-36 1RCS RCS-063 2

High 2-RCS18A High TT Medium S6-729-6 WIB-378 1

1.4-19 1RCS RCS-065 2

High 2-RCS18B High TT Medium S6-728-6 WIB-431 1

1.4-20 1RCS RCS-067 2

High 2-RCS18C High UT Medium S6-727-6 WIB-367 1

1.4-21 2CVCS CVCS-008A 2

High 2-CVCS04A High TASCS, TT Medium S6-51-2 WIB-790 1

1.4-37 2CVCS CVCS-005 2

High 2-CVCS02A High TASCS, U Medium S6-50-3 WIB-189, WIB-188, WIB-187, WIB-4 1.4-31 186___6 Page 102

ASME Sec. Xl Code Category Unit 2 Risk Ranking Tables Note: Underlined welds are selected per RIISI. Bold & Italicized print indicates weld has been examined previously.

System Risk Characterization Consequence Failure Potential Lines in Weld 1 Sketch System Segment Category I Rank ID Rank DMs R

SegmentRWelds in Segment Count I No(s).

2CVCS CVCS-001 2

High 2-CVCS01A High TT Medium S6-246-3 WIB-315 1

1.4-31 2CVCS CVCS-003 2

High 2-CVCS01A High TT Medium S6-246-3 WIB-311 1

1.4-31 2CVCS CVCS-008B 2

High 2-CVCS04A High T1 Medium S6-51-2 WIB-789 1

1.4-37 3SIS SIS-053 2

High 2-CVCS13A High TT Medium S6-1991-1-1/2 WIB-511, WIB-510, WIB-509, WIB-4 1.4-60 508 3SIS SIS-054 2

High 2-CVCS13B High TT Medium S6-1992-1-1/2 WIB-564-04, WIB-563-04, WIB-562, 4

1.4-62 WIB-561 3SIS SIS-055 2

High 2-CVCS13C High TT Medium S6-1993-1-1/2 WIB-660, WIB-659, WIB-658, WIB-6 1.4-64 657, WIB-656, WIB-655 3SIS SIS-056 2

High 2-CVCS13D High TT Medium S6-1994-1-1/2 WIB-737-04, WIB-736-04, WIB-735, 4

1.4-66 WIB-733 4RHRS RHRS-015 2

High 2-RHRO6 High TASCS Medium S1-118-8 WIC-67, WIC-68 2

2.2-26A 4RHRS RHRS-018 2

High 2-RHRO6 High TASCS Medium S1-1669-8 WIC-178 1

2.2-14 4RHRS RHRS-020 2

High 2-RHRO6 High TASCS Medium S1-985-12 WIC-126, WIC-127, WIC-128 3

2.2-3 4RHRS RHRS-022 2

High 2-RHR06 High TASCS Medium S1-2212-8 WIC-174, WIC-175 2

2.2-14 4RHRS RHRS-024 2

High 2-RHRO6 High TASCS Medium S1-2458-8 WIC-122 1

2.2-3 4RHRS RHRS-027 2

High 2-RHRO6 High TASCS Medium S1-119-8 RB-119-27, RB-119-28 2

2.2-27A 1RCS RCS-002 4

Medium 2-RCS01 High None Low

  • -9-27-1/2 WIB-RC-1-12, WIB-RC-1-13, WIB-RCO 5

f 1-14, WIB-RC-1-15, WIB-RC 16(SE)*

1RCS RCS-003 4

Medium 2-RCS01 High None Low S6-253-10 WIB-37 1

1.4-1 1RCS RCS-004 4

Medium 2-RCS01 High None Low S6-1140-2 WIB-971 1

1.4-1 1RCS RCS-005 4

Medium 2-RCS01 High None Low S6-13-4 WIB-55 1

1.4-1 1RCS RCS-007 4

Medium 2-RCS01A High None Low S6-1140-2 WIB-975A, WIB-975B, WIB-975C, 8

1.4-55 WIB-975D, WIB-975E, WIB-975F,

_WIB-975G, WIB-975H 1RCS RCS-009 4

Medium 2-RCS02 High None Low

  • -10-27-1/2 WIB-RC-2-12, WlB-RC-2-13, WIB-RC.

5 1.4-2 2-14, WIB-RC-2-15, WIB-RC Page 103

ASME Sec. XI Code Category Unit 2 Risk Ranking Tables Note: Underlined welds are selected per RIISI. Bold & Italicized print indicates weld has been examined previously.

Risk Characterization Consequence Failure Potential Lines in Welds in Segment Weld Sketch System Seqment I Category I Rank ID Rank DMs Rank Segment WeldsinSegment Count No(s).

1RCS RCS-010 4

Medium 2-RCS02 High None Low S6-254-10 WIB-163 1

1.4-2 1RCS RCS-011 4

Medium 2-RCS02 High None Low S6-1146-2 WIB-991, WIB-992B, WIB-992C 3

1.4-2 1.4-56 1RCS RCS-012 4

Medium 2-RCS02 High None Low S6-14-4 WIB-104 1

1.4-2 1RCS RCS-014 4

Medium 2-RCS03 High None Low

  • -11-27-1/2 WIB-RC-3-12, WlB-RC-3-13, WIB-RC 5

1.4-3 3-14, WlB-RC-3-15, WIB-RC 16(SE)*

1RCS RCS-015 4

Medium 2-RCS03 High None Low S6-255-10 WIB-192 1

1.4-3 1RCS RCS-016 4

Medium 2-RCS03 High None Low S6-1152-2 WIB-1012, WIB-1013A, WIB-1013B 3

1.4-3 1.4-57 1RCS RCS-019 4

Medium 2-RCS04 High None Low

  • -12-27-1/2 WIB-RC-4-12, WIB-RC-4-13, WIB-RC-5 1.4-4 4-14, WIB-RC-4-15, WIB-RC 16(SE)*

1 RCS RCS-020 4

Medium 2-RCS04 High None Low S6-256-10 WIB-289 1

1.4-4 1RCS RCS-021 4

Medium 2-RCS04 High None Low S6-1159-2 WIB-1026, WIB-1026A, WIB-1026C 3

1.4-4 1.4-58 1RCS RCS-024 4

Medium 2-RCS05 High None Low

  • -1-29 WlB-RC-1-1(SE)*, WIB-RC-1-2, WIB-6 1.4-1 RC-1-3, WIB-RC-1-4, WIB-RC-1-5, WIB-RC-1-5(SE)*

1 RCS RCS-025 4

Medium 2-RCS05 High None Low S6-235-6 WIB-1 1

1.4-1 1RCS RCS-026 4

Medium 2-RCS06 High None Low

  • -2-29 WIB-RC-2-1(SE)*, WlB-RC-2-2, WIB-5 1.4-2 RC-2-3, WIB-RC-2-4, WIB-RC-2-5, WIB-RC-2-5(SE)*

1 RCS RCS-028 4

Medium 2-RCS06 High None Low S6-236-6 WIB-105 1

1.4-2 1RCS RCS-029

.4 Medium 2-RCS07 High None Low

  • -3-29 WlB-RC-3-1(SE)*, WIB-RC-3-2, WIB-6 1.4-3 RC-3-3, WIB-RC-3-4, WIB-RC-3-5, WIB-RC-3-5(SE)*

1 RCS RCS-030 4

Medium 2-RCS07 High None Low S6-237-6 WIB-232 1

1.4-3 1RCS RCS-031 4

Medium 2-RCS08 High None Low

  • -4-29 WlB-RC-4-1(SE)*, WIB-RC-4-2, WIB-6 1.4-4 RC-4-3, WIB-RC-4-4, WIB-RC-4-5, WIB-RC-4-5(SE)*

1RCS RCS-032 4

Medium 2-RCS08 High None Low S6-109-14 WIB-243 1

1.4-4 Page 104

ASME Sec. XI Code Categfor Unit 2 Risk Ranking Tables Note: Underlined welds are selected per RIISI. Bold & Italicized print indicates weld has been examined previously.

Risk Characterization Consequence Failure Potential Lines in Weld Sketch Systemaceiato oseune emn Welds in SegmentCon kec SSegment I Category 1 Rank ID Rank DMs Rank Segment Count Nos[.

1RCS RCS-033 4

Medium 2-RCS09 High None Low

  • -5-31 W/B-RC-1-6(SE)*, WIB-RC-1-6, WIB-7 1.4-1 RC-1-7, WIB-RC-1-8, WIB-RC-1-9, WIB-RC-1-10, WIB-RC-1-11 1RCS RCS-034 4

Medium 2-RCS09 High None Low S6-1141-3 WIB-17, WIB-18A 2

1.4-1 1.4-27 1RCS RCS-035 4

Medium 2-RCS09 High None Low S6-958-2 WIB-500 1

1.4-1 1RCS RCS-036 4

Medium 2-RCS10 High None Low

  • -6-31 W/B-RC-2-6(SE)*, WIB-RC-2-6, WIB-7 1.4-2 RC-2-7, WIB-RC-2-8, WIB-RC-2-9, WIB-RC-2-10, WIB-RC-2-11 1RCS RCS-037 4

Medium 2-RCS10 High None Low S6-1147-3 WIB-123, WIB-124, WIB-124A 3

1.4-2 1.4-28 1RCS RCS-038 4

Medium 2-RCS10 High None Low S6-24-3 WIB-142 1

1.4-2 1RCS RCS-039 4

Medium 2-RCS11 High None Low

  • -7-31 W/B-RC-3-6(SE)*, WIB-RC-3-6, WIB-7 1.4-3 RC-3-7, WIB-RC-3-8, WIB-RC-3-9, WIB-RC-3-10, WIB-RC-3-11 1RCS RCS-040 4

Medium 2-RCS1 1 High None Low S6-1153-3 WIB-204, WIB-205A 2

1.4-29 1

_1.4-3 1RCS RCS-041 4

Medium 2-RCS1 1 High None Low S6-960-2 WIB-649 1

1.4-3 1RCS RCS-042 4

Medium 2-RCS12 High None Low

  • -8-31 W/B-RC-4-6(SE)*, WIB-RC-4-6, WIB-7 1.4-4 RC-4-7, WIB-RC-4-8, WIB-RC-4-9, WIB-RC-4-10, WIB-RC-4-11 1RCS RCS-043 4

Medium 2-RCS12 High None Low S6-1158-3 WIB-268, WIB-269A 2

1.4-30 1

_1.4-4 1RCS RCS-044 4

Medium 2-RCS12 High None Low S6-961-2 WIB-722 1

1.4-4 1RCS RCS-047 4

Medium 2-RCS14A High None Low S6-13-4 WIB-56, WIB-57, WIB-58, WIB-59, 14 1.4-23 WIB-59A, WIB-59B, WIB-60, WIB-61, WIB-62, WIB-63, WIB-64, WIB-65C, WlB-65D, WIB-65B Page 105

ASME Sec. XI Code CategoryUnit 2 Risk Ranking Tables Note: Underlined welds are selected per RIISL Bold & Italicized print indicates weld has been examined previously.

Risk Characterization Consequence Failure Potential Lines in WedWeld 1 Sketch System Segment I Category I Rank ID Rank DMs I Rank Segment Welds in Segment Count No(s).

1RCS RCS-048 4

Medium 2-RCS14B High None Low S6-13-4 WIB-66A, WIB-66B, WIB-67, WIB-68, 39 1.4-23 WIB-69, WIB-70, WIB-71, WIB-72, 1.4-24 WIB-73, WIB-74, WIB-75, WIB-76, 1.4-26 S6-15-4 WIB-77, WIB-78, WIB-78A, WIB-79 WIB-318, WIB-319, WIB-320, WIB-321, WIB-322, WIB-323, WIB-324, WIB-325, WIB-326, WIB-327, WIB-328, WIB-329, WIB-330, WIB-331, WIB-332, WIB-333, WIB-334, WIB-335, WIB-336, WIB-337, WIB-338, WIB-339, WIB-340 1RCS RCS-050 4

Medium 2-RCS14B High None Low S6-15-4 WIB-345 (OL), WIB-345(SE)*(OL) 2 1.4-26 1RCS RCS-051 4

Medium 2-RCS14B High None Low S6-14-4 WIB-92B, WIB-92A, WIB-91, WIB-90, 14 1.4-24 WIB-89, WIB-88, WIB-87, WIB-86, 1.4-25 WIB-85, WIB-84, WIB-83, WIB-82, WIB-81, WIB-80 1RCS RCS-052 4

Medium 2-RCS15A High None Low S6-14-4 WIB-103, WIB-102, WIB-101, WIB-13 1.4-25 100, WIB-99, WIB-98A, WIB-98, WIB-97, WIB-96, WIB-95, WIB-94, WIB-93B. WIB-93A 1RCS RCS-053 4

Medium 2-RCS16 High None Low S6-730-6 WIB-380(SE)*(OL), WIB-380 (OL),

21 1.4-22 WIB-381, WIB-382, WIB-383, WIB-1.4-35 384, WIB-385, WIB-386, WIB-387, S6-4081-4 WIB-388, WIB-389, WIB-390, WIB-S6-1172-3 391 WIB-392, WIB-393, WIB-394, WIB-395 WIB-396, WIB-397, WIB-398, WIB-1_

399 1RCS RCS-054 4

Medium 2-RCS16 High None Low S6-1171-3 WIB-405, WIB1406, WIB-407, WIB-4 1.4-34 408 1RCS RCS-055 4

Medium 2-RCS16 High None Low S6-1195-3 WIB-412, WIB-413, WIB-414, WIB-6 1.4-36 415, WIB-416, WIB-417 1RCS RCS-056 4

Medium 2-RCS17A High None Low S6-1171-3 WIB-409, WIB-409A, WIB-410, WIB-4 1.4-34 1_1___1_1_1_

410A 1RCS RCS-058 4

Medium 2-RCS17B High None Low S6-1172-3 WIB-400, WIB-401, WIB-402, WIB-4 1.4-35 1

1_

1403 Page 106

ASME Sec. Xl Code Category Unit 2 Risk Ranking Tables Note: Underlined welds are selected per RIISI. Bold & Italicized print indicates weld has been examined previously.

Risk Characterization Consequence Failure Potential Lines in Weld Sketch System II S2etWelds in Segment Conts Segment Category Rank ID Rank DMs Rank Segment WeIdsFnSegment Count No(s).

1RCS RCS-060 4

Medium 2-RCS17C High None Low S6-1195-3 WIB-418, WIB-419, WIB-420, WIB-4 1.4-36 421 1RCS RCS-062 4

Medium 2-RCS18A High None Low S6-729-6 WIB-369(SE)*(OL), WIB-369 (OL),

9 1.4-19 WIB-370, WIB-371, WIB-372, WIB-373, WIB-374, WIB-375, WIB-377 1RCS RCS-064 4

Medium 2-RCS18B High None Low S6-728-6 WIB-423(SE)*(OL), WIB-423 (OL),

9 1.4-20 WIB-424, WIB-425, WIB-426, WIB-427, WIB-428, WIB-429, WIB-430 1RCS RCS-066 4

Medium 2-RCS18C High None Low S6-727-6 WIB-359(SE)*(OL), WIB-359 (OL),

9 1.4-21 WIB-360, WIB-361, WIB-362, WIB-363, WIB-364, WIB-365, WIB-366 1RCS RCS-068 4

Medium 2-RCS19A High None Low S6-958-2 WIB-501, WIB-502, WIB-503, WIB-4 1.4-44 504 1RCS RCS-070 4

Medium 2-RCS20A High None Low S6-24-3 WIB-143, WIB-143A, WIB-143B, WIB-19 1.4-33 144, WIB-146, WIB-147, WIB-148, WIB-150, WIB-151, WIB-1 52, WIB-152A, WIB-153, WIB-154, WIB-155, WIB-156, WIB-158, WIB-1 59, WIB-160, WIB-160A 1RCS RCS-071 4

Medium 2-RCS20A High None Low S6-24-3(1)

WIB-145 6

1.4-33 S6-959-2 WIB-1006, WIB-1007, WIB-1007A, 1.4-45 WIB-1008, WIB-1009 1RCS RCS-073 4

Medium 2-RCS21A High None Low S6-960-2 WIB-650, WIB-651 2

1.4-46 1RCS RCS-075 4

Medium 2-RCS22A High None Low S6-961-2 WIB-723, WIB-724, WIB-725, WIB-4 1.4-47 1_

94A 1RCS RCS-078 4

Medium 2-SI05B High None Low S6-109-14 WIB-244 1

1.4-10 IRCS RCS-080 4

Medium 2-SI05B High None Low S6-109-14 WIB-251, WIB-251A, WIB-252, WIB-5 1.4-10 253, WIB-254 2CVCS CVCS-002 4

Medium 2-CVCS01A High None Low S6-246-3 WIB-314, WIB-313, WIB-312 3

1.4-31 2CVCS CVCS-006 4

Medium 2-CVCS02A High None Low S6-50-3 WIB-1 85, WIB-184 2

1.4-31 2CVCS CVCS-015 4

Medium 2-CVCS06A High None Low S6-45-4 RB-45-1, WIC-45A, RB-45-2, RB-45-3 8

2.2-38 04, RB-45-4, RB-45-5, RB-45-7, RB-45-8 2CVCS CVCS-016 4

Medium 2-CVCS06A High None Low S6-45-4(1)

RB-45-6 2

2.2-38 S6-1466-2 08-WIC-1466A 2.2-63 2CVCS CVCS-017 4

Medium 2-CVCS06B High None Low S6-46-4 WIC-46A, RB-46-1-99, RB-46-1A-99, 10 2.2-41 RB-46-2, RB-46-3, RB-46-4, RB-46-5,

_RB-46-6, RB-46-8, RB-46-9 Page 107

ASME Sec. Xl Code Category Unit 2 Risk Ranking Tables Note: Underlined welds are selected per RIISI. Bold & Italicized print indicates weld has been examined previously.

System Risk Characterization Consequence Failure Potential Lines in Welds in Segment Weld ][ Sketch Segment Category I Rank ID Rank IDMs Rank Segment Count No(s).

2CVCS CVCS-018 4

Medium 2-CVCS06B High None Low

$6-46-4(1)

RB-46-7 2

2.2-41 S6-1468-2 08-RB-1468-1 2.2-64 2CVCS CVCS-064 4

Medium 2-RCS23A High None Low S6-54-2 WIB-853, WIB-852, WIB-851, WIB-13 1.4-40 850, WIB-849, WIB-848, WIB-847, WIB-846, WIB-845, WIB-844, WIB-

$6-54-1-1/2 843 WIB-842, WIB-841 2CVCS CVCS-067 4

Medium 2-RCS24A High None Low S6-55-2 WIB-865, W1B-864, WIB-863A, WIB-25 1.4-41 S6-5398-1-1/2 858U WIB-858T, WIB-858S, WIB-858R, WIB-858Q, WIB-858P, WIB-858N, WIB-858M, WIB-858L, WIB-858K, WIB-858J, WIB-8581, WlB-858H, WIB-858G, WIB-858F, WIB-858E, WIB-8580, WIB-858C, WIB-858B, WIB-858A WIB-857-WIR-856_

2CVCS CVCS-070 4

Medium 2-RCS25A High None Low S6-56-2 08-WIB-878, 08-WIB-877, WIB-876, 28 1.4-42 WIB-875, WIB-870X, WIB-870W, S6-56-1-1/2 WIB-870V, WIB-870U WIB-870T, WIB-870S, WIB-870R, WIB-870Q, WIB-870P, WIB-870N, WIB-870M, WlB-870L, WIB-870K, WIB-870J, WIB-870H, WIB-870G, WIB-870F, WIB-870E, WIB-870D, WIB-870C, WIB-870B, WIB-870A, WIB-869. WIB-868 2CVCS CVCS-073 4

Medium 2-RCS26A High None Low S6-57-2 WIB-893, WIB-892, WIB-891, WIB-21 1.4-43 S6-57-1-1/2 883R WIB-883Q, WIB-883P, WIB-883N, WIB-883M, WIB-883L, WIB-883K, WIB-883J, WIB-883H, WIB-883G, WIB-883F, WIB-883E, WIB-883D, WIB-883C, WIB-883B, WIB-883A, WIB-882. WIB-881 3SIS SIS-001 4

Medium 2-ACC01A High None Low S6-253-10 WIB-40, WIB-39, WIB-38 3

1.4-6 3SIS SIS-002 4

Medium 2-ACC01B High None Low S6-254-10 WIB-166, WIB-165, WIB-164 3

1.4-7 3SIS SIS-003 4

Medium 2-ACCO0C High None Low S6-255-10 WIB-196, WIB-195, WIB-194, WIB-4 1.4-8 193 3SIS SIS-004 4

Medium 2-ACC01D High None Low S6-256-10 WIB-293, WIB-292, WIB-291, WIB-4 1.4-9 1

1_290 Page 108

ASME Sec. XI Code Categlo nit 2 Risk Ranking Tables Note: Underlined welds are selected per RIISI. Bold & Italicized print indicates weld has been examined previously.

Risk Characterization Consequence Failure Potential Lines in WtWeld Sketch Syst Segment Category I Rank ID Rank DMs Rank Segment Welds in Segment Count No(s).

3SIS SIS-027 4

Medium 2-CVCS05A High None Low S2-1988-8 RB-1988-1, RB-1988-2, RB-1988-3, 9

2.2-28 RB-1988-4, RB-1988-5, RB-1988-6, RB-1988-7, WIC-1054, WIC-1055 3SIS SIS-028 4

Medium 2-CVCS05A High None Low S2-1987-8 WIC-1052, RB-1987-1, RB-1987-2, RB 6

2.2-28 1987-3, RB-1987-4, WIC-1053 3SIS SIS-032 4

Medium 2-CVCS1O High None Low S6-1975-4 RB-1975-4, RB-1975-5, RB-1975-6 39 2.2-15 S6-2032-6 RB-2032-1, WIC-1033, WIC-1034, RB-2.2-47 2032-3, RB-2032-4, RB-2032-5, WIC-2.2-48 S6-2033-4 319A 2.2-49 WIC-2033A, RB-2033-1, RB-2033-2, 2.2-51 RB-2033-3, RB-2033-4, RB-2033-5, 2.2-53 S6-1978-4 RB-2033-6, RB-2033-7, RB-2033-8, S6-282-3 RB-2033-9 WIC-1978A, RB-1978-1, RB-1978-2, S6-1016-3 RB-1 978-3 WIC-282A, RB-282-1, RB-282-2, RB-282-3, RB-282-4, RB-282-5 WIC-1016A, RB-1016-1, RB-1016-2, RB-1016-3, RB-1016-4, RB-1016-5, RB-1016-6, RB-1016-7, RB-1016-8 3SIS SIS-033 4

Medium 2-CVCS10 High None Low

$6-2032-6(1)

RB-2032-2 4

2.2-15 S6-1974-4 WIC-1974A, RB-1974-5, RB-1974-6 2.2-46 3SIS SIS-034 4

Medium 2-CVCS10 High None Low S6-1979-4 RB-1979-1, WIC-1979A, RB-1979-2, 8

2.2-50 RB-1979-3, RB-1979-4, RB-1979-5 2.2-52 S6-283-3 RB-283-2, RB-283-1 3SIS SIS-063 4

Medium 2-RHRO6 High None Low S6-508-8 WIC-72 1

2.2-30 3SIS SIS-064 4

Medium 2-RHRO6 High None Low S6-509-8 RB-509-1 1

2.2-33 3SIS SIS-073 4

Medium 2-RHR11A High None Low S6-235-6 WIB-5, WIB-4, WIB-3, WIB-2 4

1.4-11 3SIS SIS-074 4

Medium 2-RHR11B High None Low S6-236-6 WIB-109, WIB-108, WIB-107, WIB-4 1.4-12 106 3SIS SIS-088 4

Medium 2-SI05A High None Low S6-237-6 WIB-236, WIB-235, WIB-234, WIB-4 1.4-13 233 3SIS SIS-089 4

Medium 2-SI05B High None Low S6-238-6 WIB-264, WIB-263, WIB-262, WIB-4 1.4-14 261 Page 109

ASME Sec. Xl Code Category Unit 2 Risk Ranking Tables Note: Underlined welds are selected per RIISI. Bold & Italicized print indicates weld has been examined previously.

S Risk Characterization Consequence

[

Failure Potential Lines in W

iWeld Sketch System Welds in Segment t

Segment Category I Rank ID Rank DMs Rank e

n Segment Count No1s.

4RHRS RHRS-007 4

Medium 2-RHR04B High None Low S1-112-8 WIC-34, WIC-35, WIC-36, WIC-37, 17 2.2-8 WIC-38, WIC-39, WIC-40, WIC-41, WIC-42, WIC-43, WIC-44, WIC-45, WIC-46, WIC-47, WIC-48, WIC-49, WIC-210 4RHRS RHRS-008 4

Medium 2-RHR04B High None Low S1-3551-14 WIC-50, WIC-51 9

2.2-2 S1-118-8 WIC-52, RB-118-1, WIC-52A, WIC-2.2-26B I_

I_

52B. WIC-52C, WIC-52D, WIC-52E 4RHRS RHRS-010 4

Medium 2-RHR04B High None Low S1-1971-8 WIC-106, WIC-107, WIC-108, WIC-8 2.2-2 109, WIC-11, WIC-110, WlC-112, WIC-113 4RHRS RHRS-012 4

Medium 2-RHR05B High None Low S1-113-8(1)

WIC-1014 17 2.2-9 S1-113-8 RB-113-1, RB-113-2, RB-113-3, RB-113-4, RB-113-5, RB-113-6, RB-113-7, RB-1l13-8, RB-1i13-9, RB-1 13-10, RB-1 13-11, RB-1 13-12, RB-1 13-13, RB-113-14, RB-113-15, RB-113-16 4RHRS RHRS-013 4

Medium 2-RHR05B High None Low

$1-119-8 RB-119-1, RB-119-2, 05-RB-119-3 3

2.2-27B 4RHRS RHRS-014 4

Medium 2-RHRO6 High None Low

$1-118-8 WIC-52F, WIC-52G, WIC-52H, WIC-19 2.2-26A 52J, WIC-52K, WIC-57A, RB-118-2, 2.2-26B WIC-57B, WIC-57C, WIC-57D, WIC-57E, WIC-57F, WIC-57G, WIC-57H, WIC-57J, WIC-57K, WIC-57L, WIC-57M, WIC-57N 4RHRS RHRS-016 4

Medium 2-RHRO6 High None Low S1-118-8 WIC-69, WIC-70, WIC-71 3

2.2-26A 4RHRS RHRS-017 4

Medium 2-RHRO6 High None Low S1-1661-8 WIC-180D, WIC-180C, WIC-180B, 4

2.2-10 WIC-180 4RHRS RHRS-019 4

Medium 2-RHRO6 High None Low S1-1669-8 WIC-177, WIC-176, WIC-173, WIC-10 2.2-14 172, WIC-171, WIC-169B, WIC-169A, 2.2-3 S1-985-12 WIC-168 WIC-1 67, WIC-166 4RHRS RHRS-021 4

Medium 2-RHRO6 High None Low S1-985-12 WIC-129, WIC-130, WIC-1 31, WIC-5 2.2-3 1_

1 132, RB-985-1 4RHRS RHRS-023 4

Medium 2-RHRO6 High None Low S1-279-8 WIC-59A, RB-279-1, RB-279-2, RB-9 2.2-29 279-3, WIC-117, WIC-118, WIC-119, WIC-120, WIC-121 4RHRS RHRS-025 4

Medium 2-RHRO6 High None Low S1-2458-8 WIC-123, WIC-125 2

2.2-3 Page 110

ASME Sec. Xl Code Category Unit 2 Risk Ranking Tables Note: Underlined welds are selected per RIISI. Bold & Italicized print indicates weld has been examined previously.

System Risk Characterization I

Consequence Failure Potential Lines in Welds in Segment Weld Sketch Segment Category [ Rank ID Rank DMs Rank Segment Count No(s).

4RHRS RHRS-026 4

Medium 2-RHRO6 High None Low S1-119-8 05-RB-119-4, 05-RB-119-5, RB-119-6, 23 2.2-27A RB-119-7, RB-119-8, RB-119-9, RB-2.2-27B 119-10, RB-119-11, RB-119-12, RB-119-13, RB-1i19-14, RB-1 19-15, RB-119-16, RB-1 19-17, RB-1 19-18, RB-119-19, RB-1 19-20, RB-1 19-21, RB-119-22, RB-1i19-23, RB-1 19-24, RB-119-25, RB-119-26 4RHRS RHRS-028 4

Medium 2-RHRO6 High None Low S1-119-8 RB-119-29, RB-119-30, RB-119-31, 5

2.2-27A RB-1 19-32, RB-1 19-33 4RHRS RHRS-029 4

Medium 2-RHRO6 High None Low Sl-735-8 WIC-265, WIC-266, WIC-267, RB-735-10 2.2-11 1, WIC-269, WIC-270, WIC-271, WIC-272, WIC-273, WIC-274 4RHRS RHRS-030 4

Medium 2-RHRO6 High None Low S1-280-8 RB-280-1, RB-280-2, RB-280-3, RB-7 2.2-11 280-4, RB-280-5, RB-280-6, RB-280-7 4RHRS RHRS-033 4

Medium 2-RHR08 High None Low S1-985-12 WIC-134, WIC-136, WIC-1 37, WIC-24 2.2-4 138, WIC-139, RB-985-2, RB-985-3, 2.2-5 RB-985-4, WIC-143, WIC-1 44, WIC-145, WIC-146, RB-985-5, RB-985-6, RB-985-7, WIC-149A, WIC-149B, RB-985-8, RB-985-9, RB-985-10, WIC-153, WIC-154, WIC-156, WIC-157 6RWST RWST-001 4

Medium 2-RWST01A High None Low S2-221-18 RB-221-1, RB-221-2 2

RWST-2-1 6RWST RWST-002 4

Medium 2-RWST01B High None Low S2-261-12 RB-261-1, RB-261-2 2

RWST-2-2 6RWST RWST-003 4

Medium 2-RWST02A-FHC High None Low S2-221-18 RB-221-3, RB-221-4, RB-221-5, RB-9 RWST-2-1 221-6, RB-221-7, RB-221-8, RB-221-9, RB-221-10, RB-221-11 6RWST RWST-004 4

Medium 2-RWST02A-High None Low S2-221-18 RB-221-15 1

RWST-2-1 MDAFW 6RWST RWST-005 4

Medium 2-RWST02A-High None Low S2-222-4 RB-222-1, RB-222-2, RB-222-3, RB-7 RWST-2-1 MDAFW 222-4, RB-222-5, RB-222-6, RB-222-7 6RWST RWST-01 1 4

Medium 2-RWST02A-SFP High None Low S2-222-4 RB-222-8, RB-222-9, RB-222-10, RB-7 RWST-2-1 222-11, RB-222-12, RB-222-13, RB-222-14 6RWST RWST-012 4

Medium 2-RWST02A-TDAFW High None Low S2-221-18 RB-221-12, RB-221-13, RB-221-14 3

RWST-2-1 Page 111

ASME Sec. XI Code Category Unit 2 Risk Ranking Tables Note: Underlined welds are selected per RIISI. Bold & Italicized print indicates weld has been examined previously.

y tem Risk Characterization Consequence Failure Potential Lines in Welds in Weld Sketch S y s te m kW l s i S e m n0 s

Segment Category Rank ID Rank DMs Rank Segment S

Count No(s).

6RWST RWST-013 4

Medium 2-RWST02B-100ELV High None Low S2-261-12 RB-261-3, RB-261-4, RB-261-5, RB-14 RWST-2-2 261-6, RB-261-7, RB-261-8, RB-261-9, RB-261-10, RB-261-11, RB-261-12, RB-261-13, RB-261-14, RB-261-15, RB-261-16 7CCW CCW-001 4

Medium 2-CCW01 High None Low K17-1357-6 WIC-1357D, RB-1357-2, WIC-1357C, 6

2.2-36 RB-1357-1, WIC-1357B, WIC-1357A 7CCW CCW-002 4

Medium 2-CCW02 High None Low K17-1357-6 RB-1357-6, WIC-1357F, RB-1357-5, 6

2.2-36 WIC-1357E, RB-1357-4, RB-1357-3 2CVCS CVCS-007 5a Medium 2-CVCS02B Medium TASCS, "

Medium S6-50-3 WIB-191, WIB-190 2

1.4-31 2CVCS CVCS-004 5a Medium 2-CVCSOIB Medium Medium S6-246-3 WIB-317, WIB-316 2

1.4-31 3SIS SIS-009 5a Medium 2-ACC02B Medium IGSCC Medium S6-254-10 WIB-168, WIB-167 2

1.4-7 3SIS SIS-013 5a Medium 2-ACC02C Medium IGSCC Medium S6-255-10 WIB-198, WIB-197 2

1.4-8 3SIS SIS-018 5a Medium 2-ACC02D Medium IGSCC Medium S6-256-10 WIB-295, WIB-294 2

1.4-9 3SIS SIS-024 5a Medium 2-ACC03A Medium IGSCC Medium S6-253-10 WIB-42, WIB-41 2

1.4-6 3SIS SIS-068 5a Medium 2-RHR10A Medium IGSCC Medium S6-235-6 WIB-7, WIB-6 2

1.4-11 3SIS SIS-072 5a Medium 2-RHR10B Medium IGSCC Medium S6-236-6 WIB-111, WIB-110, WIB-109hA 3

1.4-12 3SIS SIS-059 5a Medium 2-RHR04A Medium TASCS Medium S1-512-14 WIC-21, WIC-20 2

2.2-25 Page 112

ASME Sec. Xl Code Catego nit 2 Risk Ranking Tables Note: Underlined welds are selected per RIISI. Bold & Italicized print indicates weld has been examined previously.

System Risk Characterization jj Consequence Failure Potential Lines in Weld Sketch Segment Category [ Rank ID I

Rank DMs Rank Segment Welds inment ent Count No(s).

3SIS SIS-061 5a Medium 2-RHR05A Medium TASCS Medium S1-513-14 RB-513-12, RB-513-13 2

2.2-6 1RCS RCS-001 6a Low 2-CVCS03 Medium None Low S6-24-3 WIB-160B, WIB-161, WIB-162 3

1.4-33 2CVCS CVCS-01 3 6a Low 2-CVCS05B Medium None Low S2-1456-8 RB-1456-1, WIC-1009, RB-1456-3, 22 2.2-7 WIC-1010, RB-1456-4 S2-43-6 RB-43-1, RB-43-2, RB-43-3, RB-43-4, RB-43-5, RB-43-6, RB-43-7, RB-43-8, RB-43-9, RB-43-1 0, RB-43-1 1, RB 12, RB-43-13, RB-43-14, RB-43-17, RB-43-15, RB-43-16 2CVCS CVCS-014 6a Low 2-CVCS05B Medium None Low

$2-1456-8(1)

RB-1456-2 20 2.2-35 S2-42-6 WIC-1056, WIC-1057, WIC-1058, 2.2-7 WIC-1059, WIC-1060, WIC-1061, FW-1, FW-2, WIC-1062, WIC-1 063, WIC-1064, RB-42-1, WIC-1065, WIC-1066, WIC-1067, WIC-1068, WIC-1069-04, WIC-1 070-04, RB-42-2 Page 113

ASME Sec. XI Code Category Unit 2 Risk Ranking Tables Note: Underlined welds are selected per RIISI. Bold & Italicized print indicates weld has been examined previously.

Syst Risk Characterization Consequence Failure Potential Lines in Welds in Segment Weld Sketch Segment Category Rank ID Rank DMs Rank Seg ment Count No(s).

2CVCS CVCS-019 6a Low 2-CVCS07 Medium None Low S6-1468-2 08-RB-1468-2, 08-RB-1468-3, 08 16 2.2-64 6, 97-5, 97-4, 97-3, 97-2, 97-1, RB-1468-8, 08-RB-1468-9, RB-1468-10, RB-1468-11, RB-1468-12, RB-1468-13, RB-1468-14, RB-1468-15 2CVCS CVCS-020 6a Low 2-CVCS07 Medium None Low S6-1468-2(1) 08-WIC-1468A 33 2.2-63 S6-1466-2 08-RB-1466-1, 08-RB-1466-2, 97-5, 2.2-64 08-97-6, 97-4, 97-3, 97-2, 97-1, RB 2.2-65 1466-8, 08-RB-1466-9, RB-1466-10, RB-1466-11, RB-1466-12, RB-1466-S6-1464-2 12A, RB-1466-12B, RB-1466-13, RB-1466-14, RB-1466-15 RB-1464-1, RB-1464-2, RB-1464-3, RB-1464-4, RB-1464-6, RB-1464-7, RB-1464-8, RB-1464-9, RB-1464-10, RB-1464-11, RB-1464-12, RB-1464-

  • 3, RB-1464-14 RB-1464-15 2CVCS CVCS-021 6a Low 2-CVCS07 Medium None Low S6-1466-2(1) 08-RB-1466-3 1

2.2-63 2CVCS CVCS-022 6a Low 2-CVCS07 Medium None Low

$6-1464-2(1)

RB-1464-5 1

2.2-65 2CVCS CVCS-023 6a Low 2-CVCS07 Medium None Low S6-1464-2(2)

WIC-1464A 1

2.2-65 2CVCS CVCS-024 6a Low 2-CVCS08 Medium None Low S6-46-4 RB-46-1 0, RB-46-1 1, RB-46-12, RB-18 2.2-15 46-13, RB-46-14, WIC-46B 2.2-40 S6-1454-6 WIC-334, WIC-333, WIC-332, WIC-2.2-41 331, WIC-121, RB-1454-1, WIC-328, S6-3678-3 WIC-327, WIC-326 06-RB-3678-1, 06-RB-3678-2, RB-3678-3 2CVCS CVCS-025 6a Low 2-CVCS08 Medium None Low S6-1475-3 RB-1475-1, RB-1475-2A, RB-1475-2B 3

2.2-42 2CVCS CVCS-026 6a Low 2-CVCS08 Medium None Low S6-1973-6 WIC-325, WIC-324, WIC-323, WIC-7 2.2-15 322, WIC-322A, WIC-321, WIC-320 2CVCS CVCS-027 6a Low 2-CVCS08 Medium None Low S6-1973-6(1)

WIC-319 9

2.2-15 S6-45-4 RB-45-9, RB-45-1 0, RB-45-1 1, RB 2.2-38 12, RB-45-13, RB-45-14, WIC-45B, I RB-45-15 2CVCS CVCS-028 6a Low 2-CVCS08 Medium None Low S6-1474-3 RB-1474-1, RB-1474-2 2

2.2-39 Page 114

ASME Sec. XI Code Category Unit 2 Risk Ranking Tables Note: Underlined welds are selected per RIISI. Bold & Italicized print indicates weld has been examined previously.

System Risk Characterization Consequence Failure Potential Lines in Welds in Segment Weld Sketch Segment Category I Rank ID Rank DMs Rank Segment Count No(s).

2CVCS CVCS-029 6a Low 2-CVCS09 Medium None Low S6-3678-3 RB-3678-4, 06-RB-3678-5, 06-RB-69 2.2-40 3678-6, WIC-3678A, RB-3678-7, RB-2.2-44 S6-48-3 3678-8, 08-RB-3678-8A, 08-RB-3678-9A, 08-RB-3678-9B, 08-RB-3678-9C, 08-RB-3678-9D, 08-RB-3678-1 OA 08-RB-48-1A, 08-RB-48-11B, RB-48-2, RB-48-3, RB-48-4, RB-48-5, WIC-48A, WIC-48B, RB-48-6, RB-48-7, RB-48-8, RB-48-9, WIC-48C, RB 10, RB-48-11, RB-48-12, RB-48-13, RB-48-14, RB-48-15, RB-48-16, RB-48-17, RB-48-18, RB-48-19, RB 20, WIC-48D, RB-48-21, RB-48-22, RB-48-23, WIC-48E, RB-48-24, RB-48-25, RB-48-26, RB-48-27, RB 28, RB-48-29, RB-48-30, RB-48-31, RB-48-32, RB-48-33, WIC-48F, RB-48 34, RB-48-35, RB-48-36, RB-48-37, RB-48-38, RB-48-39, RB-48-40, RB-48-41, RB-48-42, RB-48-43, RB 44, RB-48-45, RB-48-46, RB-48-47, RB-48-48, RB-48-49, RB-48-50 2CVCS CVCS-030 6a Low 2-CVCS09 Medium None Low S6-1475-3 RB-1475-3A, RB-1475-3B, WIC-9 2.2-42 1475A, RB-1475-4, RB-1475-4A, RB-1475-4B, RB-1475-5, RB-1475-6, RB-1475-7 2CVCS CVCS-031 6a Low 2-CVCS09 Medium None Low S6-47-3 Welds deleted (new piping ran, see 0

2.2-43 line 47 below) 2CVCS CVCS-032 6a Low 2-CVCS09 Medium None Low S6-1312-3 RB-1312-1, RB-1312-2, RB-1312-3, 4

2.2-45 RB-1 312-4 2CVCS CVCS-033 6a Low 2-CVCS09 Medium None Low S6-1474-3 RB-1474-3, RB-1474-4, RB-1474-5, 23 2.2-39 RB-1474-6, WIC-1474, RB-1474-7, RB 2.2-55 S6-53-3 1474-8, RB-1474-9 RB-53-1, RB-53-2, RB-53-3, RB-53-4, 08-RB-53-4A, 08-RB-53-4B, RB-53-5, RB-53-6, 08-RB-53-6A, 08-RB-53-6B, 08-RB-53-6C, 08-RB-53-6D, 08-RB-53 11, RB-53-12, RB-53-13 Page 115

ASME Sec. XI Code Category nit 2 Risk Ranking Tables Note: Underlined welds are selected per RIISI. Bold & Italicized print indicates weld has been examined previously.

Risk Characterization Consequence Failure Potential Lines in Weld Sketch

[System

_ld

_Segme__

_t_

Segment Category [ Rank ID Rank DMs Rank Segment Welds in Segment Count No(s).

2CVCS CVCS-034 6a Low 2-CVCS09 Medium None Low S6-52-3 RB-52-1, WIC-52A, RB-52-2, RB-52-3, 36 2.2-54 RB-52-4, RB-52-5, RB-52-6, WIC-52B, 2.2-59 RB-52-7, RB-52-8, RB-52-9, RB 2.2-66 S6-2044-3 10, RB-52-1 1, RB-52-12, RB-52-13 RB-2044-1, RB-2044-2, RB-2044-3, S6-3673-2 RB-2044-4, WIC-2044A, RB-2044-5, RB-2044-6 WIC-3673A, RB-3673-1, WIC-3673B, RB-3673-3, RB-3673-4, RB-3673-5, RB-3673-6, RB-3673-1 0, RB-3673-1 1, RB-3673-12, RB-3673-13, RB-3673-14, RB-3673-15, RB-3673-16 2CVCS CVCS-035 6a Low 2-CVCS09 Medium None Low S6-1477-2 RB-1477-1, RB-1477-2, RB-1477-3, 45 2.2-60 RB-1477-4, RB-1477-5, RB-1477-6, 2.2-61 RB-1477-7, RB-1477-11, RB-1477-12, 2.2-68 RB-1477-13, RB-1477-14, RB-1477-

$6-2046-3 16, WIC-1477A, WIC-1477B S6-746-3 RB-2046-1, RB-2046-2, RB-2046-3, RB-2046-4 RB-746-1, RB-746-2, RB-746-3, RB-746-4, RB-746-5, WIC-746A, RB-746-6, RB-746-7, RB-746-8, RB-746-9, RB-746-10, RB-746-1 1, RB-746-12, RB-746-13, RB-746-14, RB-746-15, RB-746-16, WIC-746B, RB-746-17, RB-746-18, RB-746-19, RB-746-20, RB-746-21, RB-746-22, RB-746-23, WIC-74r, RR-749-94 2CVCS CVCS-036 6a Low 2-CVCS09 Medium None Low

$6-3673-2(1)

RB-3673-2 1

2.2-66 2CVCS CVCS-037 6a Low 2-CVCS09 Medium None Low S6-3673-2(2)

RB-3673-7, RB-3673-8, RB-3673-9 3

2.2-66 2CVCS CVCS-038 6a Low 2-CVCS09 Medium None Low S6-1477-2(1)

RB-1477-8, RB-1477-9, RB-1477-10 3

2.2-68 2CVCS CVCS-039 6a Low 2-CVCS09 Medium None Low S6-1477-2(2)

RB-1477-15 1

2.2-68 Page 116

ASME Sec. Xl Code Categ init 2 Risk Ranking Tables Note: Underlined welds are selected per RIISI. Bold & Italicized print indicates weld has been examined previously.

System

- Risk Characterization Consequence Failure Potential Lines in Welds in Segment Weld Sketch Segment [ Category I Rank ID Rank DMs Rank Segment WeldsinSegment Count No1s.

2CVCS CVCS-040 6a Low 2-CVCS09 Medium None Low S6-2047-3 RB-2047-7, RB-2047-6, RB-2047-5, 22 2.2-56 RB-2047-4, RB-2047-3, RB-2047-2, 2.2-67 S6-3674-2 RB-2047-1, WIC-2047A WIC-3674A, RB-3674-1, RB-3674-2, RB-3674-4, RB-3674-5, RB-3674-6, RB-3674-7, RB-3674-1 1, RB-3674-12, RB-3674-13, RB-3674-14, RB-3674-15, RB-3674-16, RB-3674-17 2CVCS CVCS-041 6a Low 2-CVCS09 Medium None Low S6-1478-2 RB-1478-1, RB-1478-2, RB-1478-3, 22 2.2-58 RB-1478-4, RB-1478-5, RB-1478-6, 2.2-69 RB-1 478-7, RB-1 478-11, RB-1 478-12, WIC-1478A, RB-1478-13, RB-1478-

$6-2048-3 15, WIC-1478B, RB-1478-16 WIC-2048A, RB-2048-1, RB-2048-2, RB-2048-3, RB-2048-4, RB-2048-5, RB-2048-6, RB-2048-7 2CVCS CVCS-042 6a Low 2-CVCS09 Medium None Low S6-1455-3 RB-1455-1, RB-1455-2, RB-1455-3 3

2.2-57 2CVCS CVCS-043 6a Low 2-CVCS09 Medium None Low S6-3674-2(1)

RB-3674-3 1

2.2-67 2CVCS CVCS-044 6a Low 2-CVCS09 Medium None Low S6-3674-2(2)

RB-3674-8, RB-3674-9, RB-3674-10 3

2.2-67 2CVCS CVCS-045 6a Low 2-CVCS09 Medium None Low S6-1478-2(1)

RB-1478-8, RB-1478-9, RB-1478-10 3

2.2-69 2CVCS CVCS-046 6a Low 2-CVCS09 Medium None Low S6-1478-2(2)

RB-1478-14 1

2.2-69 2CVCS CVCS-047 6a Low 2-CVCS09 Medium None Low S6-1683-3 WIC-1683A, RB-1683-5, RB-1683-4, 6

2.2-62 RB-1683-1, RB-1683-2, RB-1683-3 Page 117

ASME Sec. XI Code Categ iUnit 2 Risk Ranking Tables Note: Underlined welds are selected per RIISI. Bold & Italicized print indicates weld has been examined previously.

System Risk Characterization Consequence Failure Potential Lines in Welds in Segment Weld Sketch Segment Category Rank ID Rank DMs Rank Segment Count No(s).

2CVCS CVCS-048 6a Low 2-CVCS09 Medium None Low S6-54-2 RB-54-1, WIC-54A, RB-54-2, RB-54-3, 97 2.2-70 RB-54-4, RB-54-5, RB-54-6, RB-54-7, 2.2-74 RB-54-8, RB-54-9, RB-54-10, RB 2.2-75 11, WIC-54B, RB-54-12, RB-54-13, 2.2-76 RB-54-15, RB-54-16, RB-54-17, RB-54-18, RB-54-19, WIC-54C, RB-54-20, RB-54-21, RB-54-23, RB-54-24, RB-54-25, RB-54-26, RB-54-27, RB 28, RB-54-29, RB-54-30, RB-54-31, RB-54-32, RB-54-33, WIC-54D, RB-54 34, WIC-54E, WIC-54F, RB-54-35, RB-54-37, RB-54-38, RB-54-39, RB-54-40, RB-54-41, RB-54-42, RB 43, RB-54-44, RB-54-45, RB-54-46, RB-54-47, RB-54-48, RB-54-49, RB-54-50, RB-54-51, RB-54-52, RB 53, RB-54-54, RB-54-55, RB-54-56, RB-54-57, RB-54-58, RB-54-59, RB-54-60, RB-54-61, RB-54-62, RB 63, RB-54-64, RB-54-65, RB-54-66, RB-54-67, RB-54-68, RB-54-69, RB-54-70, RB-54-71, RB-54-72, RB 74, RB-54-75, RB-54-76, RB-54-77, RB-54-78, RB-54-79, RB-54-80, WIC-54H, WIC-54J, RB-54-81, RB-54-82, RB-54-83, RB-54-84, RB-54-85, RB-54-86, RB-54-87, RB-54-88, RB 2CVCS CVCS-049 6a Low 2-CVCS09 Medium None Low S6-54-2(1)

RB-54-14 1

2.2-70 2CVCS CVCS-050 6a Low 2-CVCS09 Medium None Low S6-54-2(2)

RB-54-22 1

2.2-70 2CVCS CVCS-051 6a Low 2-CVCS09 Medium None Low S6-54-2(3)

RB-54-36 1

2.2-74 2CVCS CVCS-052 6a Low 2-CVCS09 Medium None Low S6-54-2(4)

WIC-54G 1

2.2-74 2CVCS CVCS-053 6a Low 2-CVCS09 Medium None Low S6-54-2(5)

RB-54-73 1

2.2-75 Page 118

ASME Sec. Xl Code Category Unit 2 Risk Ranking Tables Note: Underlined welds are selected per RIISI. Bold & Italicized print indicates weld has been examined previously.

System Risk Characterization Consequence Failure Potential Lines in Welds in Segment Weld Sketch

[jSegment Category I Rank ID Rank I Ms Rank Segment Count No 2CVCS CVCS-054 6a Low 2-CVCS09 Medium None Low S6-55-2 RB-55-1, RB-55-2, RB-55-3, RB-55-4, 67 2.2-71 RB-55-5, RB-55-6, WIC-55A, RB-55-7, 2.2-77 RB-55-8, RB-55-9, RB-55-10, RB 2.2-78 12, RB-55-13, RB-55-14, WIC-55B, RB-55-15, RB-55-16, WIC-55C, RB-55 17, RB-55-19, RB-55-20, RB-55-21, RB-55-22, RB-55-23, RB-55-24, RB-55-25, RB-55-26, RB-55-27, RB 28, RB-55-29, WIC-55D, RB-55-30, RB-55-31, RB-55-32, RB-55-33, WIC-55E, RB-55-35, RB-55-36, RB-55-37, RB-55-38, RB-55-39, WIC-55F, RB 40, RB-55-41, WIC-55G, RB-55-42, RB-55-43, RB-55-44, RB-55-45, RB-55-46, RB-55-47, RB-55-48, RB 49, RB-55-50, RB-55-51, RB-55-52, RB-55-53, RB-55-54, RB-55-55, RB-55-56, RB-55-57, RB-55-58, RB 59, RB-55-60, RB-55-61, RB-55-62, RB-55-63 2CVCS CVCS-055 6a Low 2-CVCS09 Medium None Low S6-55-2(1)

RB-55-11 1

2.2-78 2CVCS CVCS-056 6a Low 2-CVCS09 Medium None Low S6-55-2(2)

RB-55-18 1

2.2-78 2CVCS CVCS-057 6a Low 2-CVCS09 Medium None Low S6-55-2(3)

RB-55-34 1

2.2-77 2CVCS CVCS-058 6a Low 2-CVCS09 Medium None Low S6-56-2 RB-56-1, RB-56-2, RB-56-3, RB-56-4, 37 2.2-72 RB-56-5, RB-56-6, WiC-56A, RB 2.2-79 7, RB-56-8, RB-56-9, WIC-56B, RB-56 2.2-80 11, RB-56-12, RB-56-13, RB-56-14, RB-56-15, RB-56-16, WIC-56C, RB-56 17, RB-56-19, RB-56-20, RB-56-21, RB-56-22, 04-RB-56-23, 04-RB-56-24, 04-WIC-56D, 04-RB-56-25, RB-56-26, RB-56-27, RB-56-28, RB-56-29, RB-56-30, RB-56-31, RB-56-32, RB 33, RB-56-34, 08-RB-56-35 2CVCS CVCS-059 6a Low 2-CVCS09 Medium None Low I6-56-2(1)

RB-56-10 1

2.2-79 2CVCS CVCS-060 6a Low 2-CVCS09 Medium None Low S6-56-2(2)

RB-56-18 1

2.2-79 Page 11 T

ASME Sec. Xl Code Category Unit 2 Risk Ranking Tables Note: Underlined welds are selected per RIISI. Bold & Italicized print indicates weld has been examined previously.

Risk Characterization Consequence Failure Potential Lines in We'ld Sketch System T

Welds in Segment ount Segment Category [ Rank ID Rank DMs Rank Segment R ount_______

2CVCS CVCS-061 6a Low 2-CVCS09 Medium None Low S6-57-2 WIC-57A, RB-57-1, RB-57-2, RB-57-3, 71 2.2-73 RB-57-4, RB-57-5, RB-57-6, RB-57-7, 2.2-81 RB-57-8, RB-57-9, RB-57-10, WIC-2.2-82 57B, RB-57-1 1, RB-57-12, RB-57-13, WIC-57C, RB-57-14, RB-57-16, RB-57-17, RB-57-18, RB-57-19, RB 20, WIC-57D, RB-57-21, RB-57-22, RB-57-24, RB-57-25, RB-57-26, RB-57-27, RB-57-28, RB-57-29, RB 30, RB-57-31, RB-57-32, RB-57-33, RB-57-34, RB-57-35, RB-57-36, RB-57-37, RB-57-38, RB-57-39, RB 40, RB-57-41, RB-57-42, RB-57-43, RB-57-44, RB-57-45, RB-57-46, RB-57-47, RB-57-48, RB-57-49, RB 50, WIC-57E, WIC-57F, RB-57-51, RB 57-52, 04-WIC-57G, 04-WIC-57H, 04-RB-57-53, RB-57-54, RB-57-55, RB-57-56, RB-57-57, RB-57-58, RB 59, RB-57-60, RB-57-61, RB-57-62, RB-57-63, RB-57-64, RB-57-65 2CVCS CVCS-062 6a Low 2-CVCS09 Medium None Low S6-57-2(1)

RB-57-15 1

2.2-81 2CVCS CVCS-063 6a Low 2-CVCS09 Medium None Low S6-57-2(2)

RB-57-23 1

2.2-73 2CVCS CVCS-066 6a Low 2-RCS23B Medium None Low S6-54-2 WIB-855, WIB-854 2

1.4-40 2CVCS CVCS-069 6a Low 2-RCS24B Medium None Low S6-55-2 WIB-867, WIB-866 2

1.4-41 2CVCS CVCS-072 6a Low 2-RCS25B Medium None Low S6-56-2 08-WIB-880, 08-WIB-879 2

1.4-42 2CVCS CVCS-075 6a Low 2-RCS26B Medium None Low S6-57-2 WIB-895, WIB-894 2

1.4-43 3SIS SIS-005 6a Low 2-ACC02A Medium None Low S6-3855-2 WIB-934, WIB-933, WIB-931, WIB-4 1.4-15 930 3SIS SIS-006 6a Low 2-ACC02A Medium None Low S6-3855-2(1)

WIB-932 1

1.4-15 3SIS SIS-007 6a Low 2-ACC02B Medium None Low S6-3845-6 WIB-182, WIB-935, WIB-181, WIB-11 1.4-16 180, WIB-179, WIB-178, WIB-177, WIB-176, WIB-175, WIB-174, WIB-173 Page 120

ASME Sec. XI Code CategorUnit 2 Risk Ranking Tables Note: Underlined welds are selected per RIISI. Bold & Italicized print indicates weld has been examined previously.

Risk Characterization Consequence Failure Potential Lines in Weld Sketch System Sement]a[teo Rank ID Rank Segme Weldsin Segment Count No(s).

3SIS SIS-008 6a Low 2-ACC02B Medium None Low S6-254-10 WIB-172, WIB-171, WIB-170, WIB-5 1.4-7 170A. WIB-169 3SIS SIS-010 6a Low 2-ACC02B Medium None Low S6-3856-2 WIB-940, WIB-939, WIB-937, WIB-4 1.4-16 936 3SIS SIS-011 6a Low 2-ACC02B Medium None Low

$6-3856-2(1)

WIB-938 1

1.4-16 3SIS SIS-012 6a Low 2-ACC02C Medium None Low S6-3846-6 WIB-203, WIB-202, WIB-941, WIB-9 1.4-17 201B, WIB-201C, WIB-201A, WIB-201, WIB-200, WIB-199 3SIS SIS-014 6a Low 2-ACC02C Medium None Low S6-3857-2 WIB-950, WIB-949, WIB-947, WIB-12 1.4-17 946, WIB-945, WIB-944, WIB-943, WIB-942D, WIB-942C, WIB-942B, WIB-942A, WIB-942 3SIS SIS-015 6a Low 2-ACC02C Medium None Low S6-3857-2(1)

WIB-948 1

1.4-17 3SIS SIS-016 6a Low 2-ACC02D Medium None Low S6-3847-6 WIB-309, WIB-308, WIB-307, WIB-12 1.4-18 306, WIB-305, WIB-304, WIB-303, WIB-302A, WIB-302B, WIB-302, WIB-301, WIB-300 3SIS SIS-017 6a Low 2-ACC02D Medium None Low S6-256-10 WIB-299, WIB-298, WIB-297, WIB-4 1.4-9 296 3SIS SIS-019 6a Low 2-ACC02D Medium None Low S6-3858-2 WIB-951, WIB-952, WIB-952A, WIB-15 1.4-50 952B, WIB-952C, WlB-952D, WIB-953, WIB-953A, WIB-953B, WIB-953C, WIB-953D, WIB-953E, WIB-954. WIB-956, WIB-957 3SIS SIS-020 6a Low 2-ACC02D Medium None Low S6-3858-2(1)

WIB-955 1

1.4-50 3SIS SIS-021 6a Low 2-ACC03A Medium None Low S6-508-8 WIC-73, WIC-74, WIC-75, WIC-77, 27 2.2-30 RB-508-1, WIC-79, WIC-80, WIC-81, 2.2-31 WIC-82, WIC-83, WIC-84, WIC-85, 2.2-32 RB-508-2, RB-508-3, RB-508-4, WIC-2.2-34 S6-3845-6 88, RB-508-5, RB-508-6, RB-508-7, WIC-90, WIC-91 WIC-92, RB-3845-1, WIC-94, WIC-95, I_

WIC-96, WIC-97 3SIS SIS-022 6a Low 2-ACC03A Medium None Low S6-508-8(1)

WIC-98 18 1.4-15 S6-3844-6 WIC-99, RB-3844-1, WIC-100A, RB-2.2-32 3844-2, WIC-1 02, WIC-1 03, WIC-1 04, 2.2-34 WIC-105, WIB-54, WIB-929, WIB-53, WIB-52, WIB-51, WIB-50, WIB-49, I

I_

_WIB-48, WIB-47 Page 121

ASME Sec. Xl Code Category Unit 2 Risk Ranking Tables Note: Underlined welds are selected per RIISI. Bold & Italicized print indicates weld has been examined previously.

system Risk Characterization Consequence Failure Potential Lines in Welds in Sement Weld Sketch Segment CategoryI Rank ID Rank DMs Rank Segment Count No(s).

3SIS SIS-023 6a Low 2-ACC03A Medium None Low S6-253-10 WIB-46, WIB-45, WIB-44, WIB-43A, 5

1.4-6 WIB-43 3SIS SIS-025 6a Low 2-ACC03B Medium None Low S6-509-8 RB-509-2, RB-509-3, RB-509-4, RB-16 2.2-33 509-5, RB-509-6, RB-509-7, RB-509-8, RB-509-9, RB-509-1 0, RB-509-1 1, S6-3847-6 RB-509-12, RB-509-13 RB-3847-1, RB-3847-2, RB-3847-3, RB-3847-4 3SIS SfS-026 6a Low 2-ACC03B Medium None Low S6-3846-6 RB-3846-1 1

2.2-33 3SIS SIS-029 6a Low 2-CVCS05B Medium None Low S2-734-8 WIC-1000, RB-734-1, WIC-O101, WIC 6

2.2-2 1002, WIC-1 003, WIC-1 004 3SIS SIS-030 6a Low 2-CVCS05B Medium None Low

$2-734-8(1)

RB-734-2 13 2.2-2 S2-4296-6 RB-4296-1, RB-4296-2, RB-4296-3, S2-7077-18 RB-4296-4, WIC-1005, WIC-1006, RB 4296-5, RB-4296-6, WIC-1007, WIC-1008 RB-7077-1i RB-7077-2 3SIS SIS-031 6a Low 2-CVCS08 Medium None Low S6-1975-4 RB-1975-1, RB-1975-2, WIC-1975A, 8

2.2-46 S6-1974-4 RB-1 975-3 2.2-47 RB-1974-1, RB-1974-2, RB-1974-3, RB-1 974-4 3SIS SIS-035 6a Low 2-CVCS1 i Medium None Low S6-1016-3 RB-1016-9, RB-1016-10, WIB-357, 6

1.4-32 WIB-356, WIB-355, WIB-354 2.2-53 3SIS SIS-036 6a Low 2-CVCS1 1 Medium None Low S6-1995-3 WIB-98Q, WIB-98P, WIB-98K, WIB-11 1.4-32 98J, WIB-350, WIB-349, WIB-348, WlB-98H, WIB-98G, WIB-98C, WIB-98B 3SIS SIS-037 6a Low 2-CVCS1 1 Medium None Low

$6-1995-3(1)

WIB-98L, WIB-98M 2

1.4-32 3SIS SIS-038 6a Low 2-CVCS11 Medium None Low S6-1995-3(2)

WIB-98D, WIB-98E 2

1.4-32 3SIS SIS-057 6a Low 2-RHRO2 Medium None Low S1-223-12 WIC-254, WIC-253A, WIC-253; RB-5 2.2-6 Sl-7169-18 7169-1, RB-7169-2 3SIS SIS-058A 6a Low 2-RHR04A Medium None Low Sl-512-14 RB-512-3, RB-512-4, WIC-24, WIC-5 2.2-25 23, WIC-22 3SIS SlS-060A 6a Low 2-RHR05A Medium None Low Sl-513-14 RB-513-7, RB-513-8, RB-513-9, RB-5 2.2-6 513-10, RB-513-11 3SIS SIS-065 6a Low 2-RHR10A Medium None Low S6-3863-2 WIB-918, WIB-917, WIB-915, WIB-4 1.4-11 914 3SIS SIS-066 6a Low 2-RHR10A Medium None Low S6-3863-2(1)

WIB-916 1

1.4-11 Page 122

ASME Sec. XI Code Category Unit 2 Risk Ranking Tables Note: Underlined welds are selected per RIISI. Bold & Italicized print indicates weld has been examined previously.

Risk Characterization Consequence Failure Potential Lines in Weld Sketch System Segment C

Rank ID Rank DMs Rank Segment Welds in Segment Count No s.

3SIS SIS-067 6a Low 2-RHR10A Medium None Low S6-235-6 WIB-11, WIB-10, WIB-9, WIB-8 4

1.4-11 3SIS SIS-069 6a Low 2-RHR1OB Medium None Low S6-3864-2 WIB-928, WIB-927, WIB-923, WIB-6 1.4-12 922, WIB-921, WIB-920 3SIS SIS-070 6a Low 2-RHR1OB Medium None Low

$6-3864-2(1)

WIB-926 1

1.4-12 3SIS SIS-071 6a Low 2-RHR1OB Medium None Low S6-236-6 WIB-116, WIB-115, WIB-114, WIB-5 1.4-12 113, WIB-112 3SIS SIS-075 6a Low 2-SI02 Medium None Low S2-1986-8 WIC-1021, RB-1986-1, RB-1986-2, 17 2.2-12 WIC-1022, RB-1986-3, WIC-1023, 2.2-13 S2-1983-6 WIC-1024, RB-1986-4 RB-1983-1, RB-1983-2, RB-1983-3, RB-1983-4, RB-1983-5, RB-1983-6, RB-1983-7, RB-1983-8, RB-1983-9 3SIS SIS-076 6a Low 2-S102 Medium None Low S2-1986-8(1)

RB-1986-5 8

2.2-13 S2-1982-6 RB-1982-1, WLC-1041, RB-1982-2, RB 2.2-16 1982-3, WIC-1042, RB-1982-4, RB-1982-5 3SIS SIS-077 6a Low 2-SI03A Medium None Low S2-1982-6 WIC-1043, WIC-1044, RB-1982-6, RB-7 2.2-16 1982-7, RB-1982-8, WIC-1045, RB-1982-9 3SIS SIS-078 6a Low 2-SI03A Medium None Low S2-5848-6 WIC-1046, WIC-1047, RB-5848-1, RB-9 2.2-16 5848-2, RB-5848-3, WIC-1048, RB-5848-4, WIC-1049, RB-5848-5 3SIS SIS-079 6a Low 2-SI03B Medium None Low S2-1983-6 RB-1983-10, RB-1983-11, RB-1983-7 2.2-12 13, RB-1983-14, RB-1983-15, RB-1983-16, RB-1983-17 3SIS SIS-080 6a Low 2-SI03B Medium None Low S2-1984-8 WIC-1015, WIC-1016, WIC-1017, RB-15 2.2-12 1984-1, WIC-1018, WIC-1019, RB-1984-2, RB-1 984-3, RB-1 984-4, WIC-1020, RB-1984-5, RB-1984-6, RB-

$2-1983-6(1) 1984-7, RB-1984-8 RB-1 983-12 4RHRS RHRS-001 6a Low 2-RHR02 Medium None Low S1-927-14 RB-927-1, WIC-5, WIC-6, WIC-7 13 2.2-1 SI-110-14 WIC-8, WIC-9, WIC-10, WIC-11, WICG 2.2-25 SI-7173-18 12, WIC-12A, WIC-13; RB-7173-1, RB 7173-2 4RHRS RHRS-002 6a Low 2-RHRO2 Medium None Low

$1-111-14 RB-111-1, RB-111-2, RB-111-3, RB-7 2.2-6 111-4, RB-111-6, RB-111-7, RB-111-8 4RHRS RHRS-003 6a Low 2-RHRO2 Medium None Low S$-111-14(i)

RB-111-5 1

2.2-6 Page 123

ASME Sec. Xl Code Category Unit 2 Risk Ranking Tables Note: Underlined welds are selected per RIISI. Bold & Italicized print indicates weld has been examined previously.

Risk Characterization Consequence Failure Potential Lines in Weld Sketch I Syte DII Wed in egen Count INo(s).

IS Segment Category I Rank ID Rank DMs Rank Segment IFSg tots 4RHRS RHRS-004 6a Low 2-RHR03A Medium None Low S1-927-14 WIC-1, WIC-2, WIC-3, WIC-4 4

2.2-1 4RHRS RHRS-005 6a Low 2-RHR03B Medium None Low S6-1665-14 WIB-255, WIB-256, WIB-257, WIB-7 1.4-10 258, WIB-259, WIB-259A, WIB-260 4RHRS RHRS-006 6a Low 2-RHR04A Medium None Low S1-110-14 WIC-14, WIC-15, WIC-16, WIC-17, 12 2.2-25 WIC-18, RB-1 10-1, WIC-1 9, WIC-28, WIC-30, WIC-31, WIC-32, WIC-33 4RHRS RHRS-011 6a Low 2-RHR05A Medium None Low S1-111-14 RB-111-9, RB-111-10, RB-111-11, RB-12 2.2-6 111-12, RB-111-13, RB-111-14, RB-111-15, RB-111-16, RB-111-17, RB-111-18, RB-111-19, RB-111-20 4RHRS RHRS-031 6a Low 2-RHR07 Medium None Low S1-1663-8 WIC-209, WIC-208, WIC-207, WIC-17 2.2-8 206, WIC-205, WIC-204, WIC-203, 2.2-9 WIC-202, WIC-201, WIC-200, WIC-199, WIC-198, WIC-197, WIC-196, WIC-1011, WIC-1012, WIC-1013 4RHRS RHRS-032 6a Low 2-RHRO7 Medium None Low S1-1661-8 WIC-195, WIC-194, WIC-193, WIC-13 2.2-10 192, WIC-191, WIC-190, WLC-189, WIC-188, WIC-187, WIC-186, WIC-185, WIC-184, WIC-180E 4RHRS RHRS-034 6a Low 2-RHRO9 Medium None Low S6-120-12 WIC-158, RB-120-1 6

2.2-5 S6-2576-8 RB-2576-1, RB-2576-2, RB-2576-3, RB-2576-4 4RHRS RHRS-035 6a Low 2-RHRO9 Medium None Low S6-2575-8 WIC-1 59, WIC-160 2

2.2-5 4RHRS RHRS-036 6a Low 2-RHR1OA Medium None Low S6-2575-8 WIB-16, WIB-913, WIB-15, WIB-14, 6

1.4-11 1

1_

_WIB-13, WIB-12 4RHRS RHRS-037 6a Low 2-RHR10B Medium None Low S6-2576-8 WIB-122, WIB-919, WlB-121, WIB-7 1.4-12 1_____

120, WIB-119, WIB-118, WIB-117 Page 124

ASME Sec. XA Code CateJgor Unit 2 Risk Ranking Tables Note: Underlined welds are selected per RIISI. Bold & Italicized print indicates weld has been examined previously.

System Risk Characterization Consequence Failure Potential Lines in Welds in Segment Weld Sketch Segment Category I Rank ID Rank DMs Rank Segment SCount Nos).

5CSS CSS-001 6a Low 2-CS01 Medium None Low S2-264-8 RB-264-1, RB-264-2, RB-264-3, RB-19 264-4, RB-264-5, RB-264-6, WIC-264A, RB-264-7, RB-264-8, RB-264-9, RB-264-10, RB-264-1 1, RB-264-12, RB-264-13, RB-264-14, WIC-264C, RB-264-15, RB-264-16, RB-264-17 5CSS CSS-002 6a Low 2-CS02 Medium None Low S2-265-8 RB-265-1, RB-265-2, RB-265-3, RB-21 265-4, RB-265-5, RB-265-6, RB-265-7, RB-265-8, RB-265-9, RB-265-10, RB-265-11, RB-265-12, RB-265-13, RB-265-14, RB-265-15, RB-265-16, RB-265-17, RB-265-18, RB-265-19, RB-265-20. RB-265-21 5CSS CSS-003 6a Low 2-CS03A Medium None Low S2-264-8 RB-264-18, RB-264-19 2

5CSS CSS-004 6a Low 2-CS03B Medium None Low S2-264-8 RB-264-20, RB-264-21, RB-264-22, 12 RB-2519-1, RB-2519-2, RB-264-25, WIC-264B, RB-264-26, RB-264-27, RB-264-28, RB-264-29, RB-264-30 5CSS CSS-005 6a Low 2-CS04A Medium None Low S2-265-8 RB-265-22, RB-265-23 2

5CSS CSS-006 6a Low 2-CS04B Medium None Low S2-2520-8 RB-2520-1, RB-2520-2, RB-2520-3, 16 S2-265-8 RB-2520-4 RB-265-24, RB-265-25, RB-265-30, RB-265-31, RB-265-32, RB-265-33, RB-265-34, RB-265-35, RB-265-36, RB-265-37, RB-265-38, RB-265-39 6RWST RWST-006 6a Low 2-RWST02A-PEN Medium None Low S2-221-18 RB-221-16, RB-221-17, RB-221-18, 10 RB-221-19, RB-221-20, RB-221-21, RB-221-22, RB-221-23, RB-221-24, RB-221-25 6RWST RWST-007 6a Low 2-RWST02A-PEN Medium None Low S1-223-12 RB-223-1, RB-223-2, RB-223-3, RB-4 223-4 6RWST RWST-008 6a Low 2-RWST02A-PEN Medium None Low S2-1986-8 RB-1986-la, RB-1986-2a, RB-1986-3a 3

6RWST RWST-009 6a Low 2-RWST02A-PEN Medium None Low S2-224-8 RB-224-1, RB-224-2, RB-224-3, RB-9 224-4, RB-224-5, RB-224-6, RB-224-I I

7, RB-224-8, RB-224-9 Page 125

ASME Sec. XI Code Category Unit 2 Risk Ranking Tables Note: Underlined welds are selected per RIISI. Bold & Italicized print indicates weld has been examined previously.

Risk Characterization Consequence Failure Potential Lines in WWeld Sketch Seystemn Welds in Segment IFCu Segment Category I Rank ID Rank DMs Rank Segment Count No s.

6RWST RWST-010 6a Low 2-RWST02A-PEN Medium None Low S2-1988-8 RB-1988-1A, RB-1988-2A, RB-1988-17 3A, RB-1988-4A, RB-1988-5A, RB-1988-6A, RB-1988-7A, RB-1988-8, RB-1988-9, RB-1 988-10, RB-1 988-11, RB-1988-12, RB-1988-13, RB-1988-14, RB-1988-15, RB-1988-16, RB-1988-17 6RWST RWST-014 6a Low 2-RWST02B-PEN Medium None Low S2-261-12 RB-261-17, RB-261-18, RB-261-19, 9

RB-261-20, RB-261-21, RB-261-22, RB-261-23, RB-261-24, RB-261-25 6RWST RWST-O15 6a Low 2-RWST02B-PEN Medium None Low S2-262-10 RB-262-1, RB-262-2, RB-262-3, RB-5 262-4, RB-262-5 6RWST RWST-016 6a Low 2-RWST02B-PEN Medium None Low S2-263-10 RB-263-1, RB-263-2, RB-263-3 3

6RWST RWST-017 6a Low 2-RWST03A Medium None Low S2-262-10 RB-262-6, RB-262-7, RB-262-8, RB-6 262-9, RB-262-10, RB-262-11 6RWST RWST-018 6a Low 2-RWST03B Medium None Low S2-263-10 RB-263-4, RB-263-5, RB-263-6, RB-6 263-7, RB-263-8, RB-263-9 8FWS FWS-006 6b (5)

Low 2-FW02A Low

TASCS, Medium K16-554-16 WICG-01-1F, WICG-01-1E, WICG 7

2.2-21 (Medium)

(FAC)

(High)

I D, WICG-01-1 iC, WICG-01-1 B, I_

I_

WICG-08-1C, WICG-08-1 A 8FWS FWS-009 6b (5)

Low 2-FW02B Low

TASCS, Medium K16-555-16 WICG-01-2E, WICG-01-2D, WICG 7

2.2-22 (Medium)

(FAC)

(High) 2C, WICG-01-2B, RB-555-13, WICG-08-2B, WICG-08-2A 8FWS FWS-011 6b (5)

Low 2-FW02C Low

TASCS, Medium K16-557-16 WICG-01-3F, WICG-01-3E, WICG 7

2.2-23 (Medium)

(FAC)

(High) 3D, WICG-01-3C, WICG-01-3B, I

I_

WICG-08-3C, WICG-08-3A 8FWS FWS-013 6b (5)

Low 2-FW02D Low

TASCS, Medium K16-556-16 WICG-01-4F, WICG-01-4E, WICG 7

2.2-24 (Medium)

(FAC)

(High) 4D, WICG-01-4C, WICG-01-4B, I_

I_

I__I__IWICG-08-4B, WICG-08-4A I

Page 126

0 0

ASME Sec. XI Code Category Unit 2 Risk Ranking Tables Note: Underlined welds are selected per RIISI. Bold & Italicized print indicates weld has been examined previously.

System Risk Characterization Consequence Failure Potential Lines in Weld Sketch Systeme Welds in Segment Segment Category I Rank ID Rank DMs Rank Segment Count No(s).

2CVCS CVCS-009 6b Low 2-CVCS04B Low TT Medium S6-51-2 WIB-840, WIB-839, WIB-835, WIB-46 1.4-37 834, WIB-833, WIB-832, WIB-831, 1.4-38 WIB-830, WIB-829, WIB-828, WIB-1.4-39 827, WIB-826, WIB-825, WIB-824, WIB-823, WIB-822, WIB-821, WIB-820, WIB-818, WIB-817, WIB-816, WIB-815, WIB-814, WIB-813, WIB-812, WIB-811, WIB-810, WIB-809, WIB-808, WIB-807, WIB-806, WIB-805, WIB-804, WIB-803, WIB-802, WIB-801, WIB-800, WIB-799, WIB-798, WIB-797, WIB-796, WIB-795, WIB-794, WIB-793, WIB-792, WIB-1_

17q1 I

Page 127

10 ASME Sec. Xl Code Category Unit 2 Risk Ranking Tables Note: Underlined welds are selected per RIISI. Bold & Italicized print indicates weld has been examined previously.

System Risk Characterization Consequence Failure Potential Lines in Welds in Segment Weld i Sketch Segment Category [ Rank ID Rank DMs Rank SegmentW Count No(s).

2CVCS CVCS-010 6b Low 2-CVCS04B Low TT Medium S6-4532-2 WIB-838B, WIB-838A, WIB-837, WIB-4 1.4-39 836 2CVCS CVCS-01 1 6b Low 2-CVCS04B Low UT Medium

$6-4532-2(1) 06-WIB-338 1

1.4-39 2CVCS CVCS-012 6b Low 2-CVCS04B Low TT Medium S6-51-2(1)

WIB-819 1

1.4-38 3SIS SIS-040 6b Low 2-CVCS12A Low IGSCC Medium S6-1991-1-1/2 WIB-512 1

1.4-60 3SIS SIS-044 6b Low 2-CVCS12B Low IGSCC Medium S6-1992-1-1/2 WIB-565-04 1

1.4-62 3SIS SIS-047 6b Low 2-CVCS12C Low IGSCC Medium S6-1993-1-1/2 WIB-661 1

1 4-64 3SIS SIS-051 6b Low 2-CVCS12D Low IGSCC Medium S6-1994-1-1/2 WIB-738-04 1

1.4-66 3SIS SIS-082 6b Low 2-S104A Low IGSCC Medium S6-237-6 WIB-237 1

1.4-13 3SIS SIS-085 6b Low 2-SI04B Low IGSCC Medium S6-238-6 WIB-266, WIB-265 2

1.4-14 8FWS FWS-001 7a (5)

Low 2-FW01A Low None (FAC)

Low (High) K16-554-16 RB-554-1, RB-554-2, RB-554-3, 5

2.2-21 (Medium)

WICG 112-1, RB-554-4 8FWS FWS-002 7a (5)

Low 2-FW01 B Low None (FAC)

Low (High) K16-555-16 RB-555-1, RB-555-2, RB-555-3, RB-5 2.2-22 (Medium) 555-4, RB-555-5 8FWS FWS-003 7a (5)

Low 2-FW01C Low None (FAC)

Low (High) K16-557-16 RB-557-1, RB-557-2, RB-557-3, RB-7 2.2-23 (Medium) 557-4, RB-557-5, RB-557-6, RB-557-7 8FWS FWS-004 7a (5)

Low 2-FWO1 D Low None (FAC)

Low (High) K16-556-16 RB-556-1, RB-556-2, RB-556-3, RB-8 2.2-24 (Medium) 556-4, RB-556-5, RB-556-6, RB-556-7, RB-556-8 8FWS FWS-005 7a (5)

Low 2-FW02A Low None (FAC)

Low (High) K16-554-16 WICG 111-1, WICG 110-1, WICG 109 4

2.2-21 (Medium) 1, WICG-08-1 B 8FWS FWS-008 7a (5)

Low 2-FW02B Low None (FAC)

Low (High) K16-555-16 RB-555-6, RB-555-7, RB-555-8, WICG 4

2.2-22 (Medium) 08-2C 8FWS FWS-010 7a (5)

Low 2-FW02C Low None (FAC)

Low (High) K16-557-16 RB-557-8, RB-557-9, RB-557-10, 4

2.2-23 (Medium)

WICG-08-3B 8FWS FWS-012 7a (5)

Low 2-FW02D Low None (FAC)

Low (High) K16-556-16 RB-556-9, RB-556-10, RB-556-11, 4

2.2-24 (Medium)

WICG-08-4C 9MSS MSS-001 7a Low 2-MS01A Low None Low K15-228-28 WICGI-IR, WICG2-1R, WICG4-1, 13 2.2-17 RB-228-1A, RB-228-1B, WICG5-1, WICG6-1, RB-228-2, RB-228-3, WICG7-1, WICG8-1, RB-228-4, WICG9-1 Page 128

ASME Sec. XI CodeCategory Unit 2 Risk Ranking Tables Note: Underlined welds are selected per RIISI. Bold & Italicized print indicates weld has been examined previously.

Risk Characterization Consequence Failure Potential Lines in Wl i

Weld Sketch System Segment Category Rank ID Rank DMs Rank Segment Count No(s).

9MSS MSS-002 7a Low 2-MS01 B Low None Low KI 5-227-28 RB-227-1 R, RB-227-2R, RB-227-3, 13 2.2-18 RB-227-4A, RB-227-4B, RB-227-5, RB 227-6, RB-227-7, RB-227-8, RB-227-9, RB-227-1 0, RB-227-1 1, RB-227-12 9MSS MSS-003 7a Low 2-MS01C Low None Low K15-226-28 RB-226-1 R, RB-226-2R, RB-226-3, 13 2.2-19 RB-226-4A, RB-226-14B, RB-226-5, RB 226-6, RB-226-7, RB-226-8, RB-226-9, RB-226-1 0, RB-226-1 1, RB-226-12 9MSS MSS-004 7a Low 2-MS01D Low None Low K15-225-28 RB-225-1R, RB-225-2R, RB-225-3, 13 2.2-20 RB-225-4A, RB-225-4B, RB-225-5, RB 225-6, RB-225-7, RB-225-8, RB-225-9, RB-225-1 0, RB-225-1 1, RB-225-12 9MSS MSS-005 7a Low 2-MS02A Low None Low K15-228-28 RB-228-5, WICG10-1, WICG19-1, 7

2.2-17 WICG20-1, WICG21-1, RB-228-6, WICG22-1 9MSS MSS-006 7a Low 2-MS02A Low None Low K15-228-8 WICG11-1, RB-228-7 2

2.2-17 9MSS MSS-007 7a Low 2-MS02A Low None Low K15-228-8(1)

WICG12-1 1

2.2-17 Page 129

ASME Sec. XI Code Category Unit 2 Risk Ranking Tables Note: Underlined welds are selected per RIISI. Bold & Italicized print indicates weld has been examined previously.

System Risk Characterization Consequence Failure Potential Lines in Welds in Segment Weld Sketch Segment ] Category I Rank ID Rank DMs Rank Segment Count No(s).

9MSS MSS-008 7a Low 2-MS02A Low None Low K1 5-228-8(2)

WICG13-1 1

2.2-17 9MSS MSS-009 7a Low 2-MS02A Low None Low K15-228-8(3)

WICG15-1, WICG14-1 2

2.2-17 9MSS MSS-010 7a Low 2-MS02A Low None Low K15-228-8(4)

WICG17-1, WICG16-1 2

2.2-17 9MSS MSS-011 7a Low 2-MS02A Low None Low K15-228-8(5)

WICG18-1 1

2.2-17 9MSS MSS-012 7a Low 2-MS02B Low None Low K15-227-28 RB-227-13, RB-227-14, RB-227-15, 7

2.2-18 RB-227-16, RB-227-17, RB-227-18, RB-227-19 9MSS MSS-013 7a Low 2-MS02B Low None Low K15-227-8 RB-227-20, RB-227-21 2

2.2-18 9MSS MSS-014 7a Low 2-MS02B Low None Low K15-227-8(1)

RB-227-22 1

2.2-18 9MSS MSS-015 7a Low 2-MS02B Low None Low K15-227-8(2)

RB-227-23 1

2.2-18 9MSS MSS-016 7a Low 2-MS02B Low None Low K15-227-8(3)

RB-227-24, RB-227-25 2

2.2-18 9MSS MSS-017 7a Low 2-MS02B Low None Low K1 5-227-8(4)

RB-227-27, RB-227-28 2

2.2-18 9MSS MSS-018 7a Low 2-MS02B Low None Low K15-227-8(5)

RB-227-26 1

2.2-18 9MSS MSS-019 7a Low 2-MS02C Low None Low K15-226-28 RB-226-13, RB-226-14, RB-226-15, 7

2.2-19 RB-226-16, RB-226-17, RB-226-18, RB-226-19 9MSS MSS-020 7a Low 2-MS02C Low None Low K1 5-1065-24 WIC-526, A, B, C 4

2.2-19 9MSS MSS-021 7a Low 2-MS02C Low None Low K15-1065-8 RB-1065-1, RB-1065-2 2

2.2-19 9MSS MSS-022 7a Low 2-MS02C Low None Low K15-1065-8(1)

RB-1065-3 1

2.2-19 9MSS MSS-023 7a Low 2-MS02C Low None Low K15-1065-8(2)

RB-1065-4 1

2.2-19 9MSS MSS-024 7a Low 2-MS02C Low None Low K15-1065-8(3)

RB-1065-5 1

2.2-19 9MSS MSS-025 7a Low 2-MS02C Low None Low K15-1065-8(4)

RB-1065-6 1

2.2-19 9MSS MSS-026 7a Low 2-MS02C Low None Low K15-1065-8(5)

RB-1065-7 1

2.2-19 Page 130

ASME Sec. XI Code Category Unit 2 Risk Ranking Tables Note: Underlined welds are selected per RIISI. Bold & Italicized print indicates weld has been examined previously.

Risk Characterization Consequence Failure Potential Lines in Weld Sketch System

[

DMs Rank Sem

[

Welds in Segment Count No s.

Segment Category 7 Ran ID Rn

~

ak SgetCut N~)

9MSS MSS-027 7a Low 2-MS02D Low None Low K15-225-28 RB-225-13, RB-225-14, RB-225-15, 7

2.2-20 RB-225-16, RB-225-17, RB-225-18, RB-225-19 9MSS MSS-028 7a Low 2-MS02D Low None Low K15-1066-24 RB-1066-1, RB-1066-2, RB-1066-3, 6

2.2-20 RB-1066-4, RB-1066-5, RB-1066-6 9MSS MSS-029 7a Low 2-MS02D Low None Low K15-1066-8 RB-1066-7, RB-1066-8 2

2.2-20 9MSS MSS-030 7a Low 2-MS02D Low None Low K15-1066-8(1)

RB-1066-9 1

2.2-20 9MSS MSS-031 7a Low 2-MS02D Low None Low K15-1066-8(2)

RB-1066-10 1

2.2-20 9MSS MSS-032 7a Low 2-MS02D Low None Low K1 5-1066-8(3)

RB-1066-11 1

2.2-20 9MSS MSS-033 7a Low 2-MS02D Low None Low K1 5-1066-8(4)

RB-1 066-12 1

2.2-20 9MSS MSS-034 7a Low 2-MS02D Low None Low KI 5-1066-8(5)

RB-1066-13 1

2.2-20 1RCS RCS-008 7a Low 2-RCS01B Low None Low S6-1140-2 WIB-975J, WIB-975K 2

1.4-55 1RCS RCS-069 7a Low 2-RCS19B Low None Low S6-958-2 WIB-505, WIB-506 2

1.4-44 1 RCS RCS-072 7a Low 2-RCS20B Low None Low S6-959-2 WIB-1 010, WIB-1 011 2

1.4-45 1RCS RCS-074 7a Low 2-RCS21B Low None Low S6-960-2 WIB-652, WIB-653 2

1.4-46 1RCS RCS-076 7a Low 2-RCS22B Low None Low S6-961-2 WIB-94B, WIB-728, WIB-730, WIB-4 1.4-47 94C 1 RCS RCS-077 7a Low 2-RCS22B Low None Low S6-961-2(1)

WIB-729 1

1.4-47 3SIS SIS-058B 7a Low 2-RHR04A-1 Low None Low

$1-512-14 WIC-27, WIC-26, WIC-1050 3

2.2-25 Page 131

ASME Sec. XI Code Category Unit 2 Risk Ranking Tables Note: Underlined welds are selected per RIISI. Bold & Italicized print indicates weld has been examined previously.

Risk Characterization Consequence Failure Potential Lines in Weld Sketch

___Segment Category Rank ID Rank DMs Rank Segment Count No(s).

3SIS SIS-060B 7a Low 2-RHR05A-1 Low None Low S1-513-14 RB-513-2, RB-513-3, RB-513-4 3

2.2-6 3SIS SIS-062 7a Low 2-RHR05A-1 Low None Low S1-513-14 RB-513-1 1

2.2-6 3SIS SIS-039 7a Low 2-CVCS12A Low None Low S6-1995-3(2)

WIB-98F 45 1.4-32 S6-1991-1-1/2 WIB-98-10, WIB-98-9, WIB-98-8, WIB-1.4-59 98-7.5, WIB-98-7, WIB-98-6, WIB 1.4-60 5, WIB-98-4, WIB-98-3, WIB-98-2, WIB-98-1, WIB-544, WIB-543, WIB-542, WIB-541, WIB-540, WIB-539B, WIB-539A, WIB-539, WIB-538, WIB-537, WIB-536, WIB-535, WIB-534, WIB-533, WIB-532, WIB-531, WIB-519, WIB-530, WIB-529, WIB-528, WIB-527, WIB-526, WIB-525, WIB-524, WIB-523, WIB-522, WIB-521, WIB-518, WIB-517, WIB-516, WIB-515, WIB-514, WIB-513 3SIS SIS-041 7a Low 2-CVCS12A Low None Low S6-1991-1-1/2(1)

WIB-520 1

1.4-60 3SIS SIS-042 7a Low 2-CVCS12B Low None Low S6-1995-3 WIB-98R 1

1.4-32 Page 132

ASME Sec. XI Code CategoryUnit 2 Risk Ranking Tables Note: Underlined welds are selected per RIISI. Bold & Italicized print indicates weld has been examined previously.

Syst Risk Characterization Consequence Failure Potential Lines in Welds in Segment e

Sketch Segment I Category I Rank ID Rank DMs Rank Segment Count No(s).

3SIS SIS-043 7a Low 2-CVCS12B Low None Low S6-1992-1-1/2 WIB-98-14, WIB-98-13, WIB-98-12, 63 1.4-61 WIB-628, WIB-627, WIB-626, WIB-1.4-62 625, WIB-624, WIB-623, WIB-622, WIB-621, WIB-620, WIB-619, WIB-618, WIB-617, WIB-616, WIB-615, WIB-614, WIB-98-10, WIB-98-9, WIB-98-8, WIB-98-7, WIB-98-6, WlB-98-5, WIB-98-4, WIB-98-3, WIB-98-2, WIB-98-1, WIB-603, WIB-602, WIB-601, WIB-600, WIB-599, WIB-596, WIB-595, WIB-594, WIB-593, WIB-592, WIB-591, WIB-590, WIB-589, WIB-588, WIB-587, WIB-586, WIB-585, WIB-584, WIB-583, WIB-582, WIB-581, WIB-580, WIB-579, WIB-578, WIB-577, WIB-576, WIB-574, WIB-573, WIB-572, WIB-571, WIB-570, WIB-569, WIB-568, WIB-567, WIB-3SIS SIS-045 7a Low 2-CVCS12B Low None Low

$6-1992-1-1/2(1)

WIB-575 1

1.4-62 3SIS SIS-046 7a Low 2-CVCS12C Low None Low S6-1995-3(1)

WIB-98N 45 1.4-32 86-1993-1-1/2 WIB-98-11, WIB-98-10, WIB-98-9, 1.4-63 WlB-98-8.5, WIB-98-8, WIB-98-7, WIB 1.4-64 98-6, WIB-98-5, WIB-98-4, WIB-98-3, WIB-98-2, WIB-98-1, WIB-690, WIB-688, WIB-687, WIB-686, WIB-685B, WIB-685A, WIB-685, WIB-684, WIB-683, WIB-682, WIB-681, WIB-680, WIB-679, WIB-678, WIB-677A, WIB-677B, WIB-677, WIB-676, WIB-675, WIB-674, WIB-673, WIB-672, WIB-671A, WIB-670, WIB-669, WIB-668, WIB-667, WIB-666, WIB-665, WIB-664, WIB-663, WIB-662 381S SIS-048 7a Low 2-CVCS12C Low None Low 86-1993-1-1/2(1)

WIB-689 1

1.4-63 3SIS S1S-049 7a Low 2-CVCS12C Low None Low

$6-1993-1-1/2(2)

WIB-671 1

1.4-64 Page 133

ASME Sec. XI Code Category Unit 2 Risk Ranking Tables Note: Underlined welds are selected per RIISI. Bold & Italicized print indicates weld has been examined previously.

Risk Characterization Consequence Failure Potential Lines in Weld Sketch Segment Category Rank ID Rank DMs Rank SeWlientn gm Count No(s).

3SIS SIS-050 7a Low 2-CVCS12D Low None Low S6-1995-3 WIB-98A 32 1.4-32 S6-1994-1-1/2 WIB-98-14, WIB-98-13, WIB-98-12, 1.4-65 WIB-98-1 1, WIB-98-1 0, WIB-98-9, 1.4-66 WIB-98-8, WIB-98-7, WIB-98-6, WIB-98-5, WIB-98-4, WIB-98-3, WIB-98-2, WIB-98-1, WIB-754, WiB-753, WIB-752, WIB-751, WIB-750, WIB-749, WIB-748, WIB-747, WIB-746, WIB-745, WIB-744, WIB-743, WIB-741, WIB-740A, WIB-740B, WIB-740, WIB-1_

739 3SIS SIS-052 7a Low 2-CVCS12D Low None Low

$6-1994-1-1/2(1)

WIB-742 1

1.4-66 3SIS SIS-081 7a Low 2-SI04A Low None Low S6-1976-2 WIB-903, WIB-902, WIB-900, WIB-13 1.4-13 899, WIB-898, WIB-897, WIB-896 1.4-48 S6-237-6 WIB-242, WIB-241A, WIB-241, WIB-240, WIB-239, WIB-238 3SIS SIS-083 7a Low 2-SI04A Low None Low S6-1976-2(1)

WIB-901 1

1.4-48 3SIS SIS-084 7a Low 2-SI04B Low None Low S6-1990-2 WIB-912, WIB-911, WIB-909, WIB-9 1.4-14 908, WIB-906, WIB-905, WIB-904 1.4-49 S6-238-6 WIB-267, WIB-266A 3SIS SIS-086 7a Low 2-S104B Low None Low S6-1990-2(1)

WIB-910 1

1.4-49 3SIS SIS-087 7a Low 2-S104B Low None Low S6-1990-2(2)

WIB-907 1

1.4-49 5CSS CSS-007 7a Low 2-CS05 Low None Low S3-325-8 RB-325-1, RB-325-2, RB-325-3, RB-6 325-4, RB-325-5, RB-325-6 5CSS CSS-008 7a Low 2-CS06 Low None Low S3-325-8 RB-326-1, RB-326-2, RB-326-3, RB-6 326-4, RB-326-5, RB-326-6 S6-47-3 RB-47-3, RB-47-4, RB-47-5, RB-47-6, 36 460585 RB-47-7, RB-47-8, RB-47-9, RB 10, RB-47-11, RB-47-12, RB-47-13, RB-47-14, RB-47-15, RB-47-16, RB-47-17, RB-47-18, RB-47-19, RB 20, RB-47-21, RB-47-22, RB-47-23, RB-47-24, RB-47-25, RB-47-26, RB-47-27, RB-47-28, RB-47-29, RB147-30, RB147-31, RB-47-32, RB-47-33, RB-47-34, RB-47-35, RB-47-36, RB-I I_

1 1

147-37. RB47-38 Page 134

ASME Sec. XI Code Category Unit 2 Risk Ranking Tables Note: Underlined welds are selected per RIISI. Bold & Italicized print indicates weld has been examined previously.

Risk Characterization Consequence Failure Potential Lines in idne nWeld Sketch Systemlsi SgetC7et Sec Seyment Category Rank ID Rank DMs Rank Segment Count No(s).

S6-7066-2 RB-7066-1, RB-7066-2, RB-7066-3, 32 460585 RB-7066-4, RB-7066-5, RB-7066-6, RB-7066-7, RB-7066-8, RB-7066-9, RB-7066-1 0, RB-7066-1 1, RB-7066-12, RB-7066-13, RB-7066-14, RB-7066-15, RB-7066-16, RB-7066-17, RB-7066-18, RB-7066-19, RB-7066-20, RB-7066-21, RB-7066-22, RB-7066-23, RB-7066-24, RB-7066-25, RB-7066-26, RB-7066-27, RB-7066-28, RB-7066-29, RB-7066-30, RB-7066-31, RB-7066-32 S6-7067-2 RB-7067-1, RB-7067-2, RB-7067-3, 13 460585 RB-7067-4, RB-7067-5, RB-7067-6, RB-7067-7, RB-7067-8, RB-7067-9, RB-7067-1 0, RB-7067-1 1, RB-7067-12, RB-7067-13 S6-7075-2 RB-7075-1, RB-7075-2, RB-7075-3, 6

460585 RB-7075-4, RB-7075-5, RB-7075-6 K16-569-3 RB-569-1, RB-569-2, RB-569-3, RB-28 516924 569-4, RB-569-5, RB-569-6, RB-569-449318 7, RB-569-8, RB-569-9, RB-569-10, RB-569-1 1, RB-569-12, RB-569-13, RB-569-14, RB-569-15, RB-569-16, RB-569-17, RB-569-18, RB-569-19, RB-569-20, RB-569-21, RB-569-22, RB-569-23, RB-569-24, RB-569-25, RB-569-26, RB-569-27, RB-569-28 K16-570-3 RB-570-1, RB-570-2, RB-570-3, RB-33 516924 570-4, RB-570-5, RB-570-6, RB-570-7, RB-570-8, RB-570-9, RB-570-10, RB-570-1 1, RB-570-12, RB-570-13, RB-570-14, RB-570-15, RB-570-16, RB-570-17, RB-570-18, RB-570-19, RB-570-20, RB-570-21, RB-570-22, RB-570-23, RB-570-24, RB-570-25, RB-570-26, RB-570-27, RB-570-28, RB-570-29, RB-570-30, RB-570-31, I RB-570-32. RB-570-33 Page 135

ASME Sec. XI Code Category Unit 2 Risk Ranking Tables Note: Underlined welds are selected per RIISI. Bold & Italicized print indicates weld has been examined previously.

Syst Risk Characterization Consequence Failure Potential Lines in Welds in Segment Weld Sketch Segment Catego I Rank ID Rank DMs Rank Segment Count No(s).

K16-571-3 RB-571-1, RB-571-2, RB-571-3, RB-26 449299 571-4, RB-571-5, RB-571-6, RB-571-7, RB-571-8, RB-571-9, RB-571-10, RB-571-11, RB-571-12, RB-571-13, RB-571-14, RB-571-15, RB-571-16, RB-571-17, RB-571-18, RB-571-19, RB-571-20, RB-571-21, RB-571-22, RB-571-23, RB-571-24, RB-571-25, RB-571-26 K1 6-572-3 RB-572-1, RB-572-2, RB-572-3, RB-28 449299 572-4, RB-572-5, RB-572-6, RB-572-7, RB-572-8, RB-572-9, RB-572-10, RB-572-1 1, RB-572-12, RB-572-13, RB-572-14, RB-572-15, RB-572-16, RB-572-17, RB-572-18, RB-572-19, RB-572-20, RB-572-21, RB-572-22, RB-572-23, RB-572-24, RB-572-25, RB-572-26, RB-572-27, RB-572-28 K16-575-3 RB-575-01, RB-575-02, RB-575-03, 9

449318 RB-575-04, RB-575-05, RB-575-06, RB-575-07, RB-575-08, RB-575-09 K16-576-3 RB-576-01, RB-576-02, RB-576-03, 9

449318 RB-576-04, RB-576-05, RB-576-06, RB-576-07, RB-576-08, RB-576-09 K1 6-577-3 RB-577-1, RB-577-2, RB-577-3, RB-6 449299 577-4, RB-577-5, RB-577-6 K1 6-578-3 RB-578-1, RB-578-2, RB-578-3, RB-6 449299 578-4, RB-578-5, RB-578-6 Red = New Green = weld Blue = Weld Magenta =

weld since replaced (like-always existed Administra last Interval for-like) but was not tive counted in change or original RIISI RIISI assessment assessme nt change 2003 Addenda Inclustion Total:

2798 Page 136

ASME Sec. X 9 Category C-A S

PRGAM PAN ITEM PARTS EXAMINED COMP/LINE WELD/COMP NO.

ISI DWG.

NDE PER.

LINE-RELIEF BLOCK TOTL-%

REQ.

NOTES CI 10 Shell Circumferential Welds C1.20 Head Circumferential Welds C1.30 Tubesheet-to-Shell Weld CI. 10 Shell Circumferential Welds C1.20 Head Circumferential Welds C1.30 Tubesheet-to-Shell Weld Repi Steam Generator None I-1 Rep[ Steam Generator Girth FW-13.01.01 1-1 Repl Steam Generator Girth FW-1 1.07.01 1-1 Repl Steam Generator None 2-1 Repl Steam Generator Girth FW-13.01.01 2-1 Repl Steam Generator Girth FW-I 1.07.01 2-1 UI: 2.1-1 N/A N/A UI: 2.1-1 UT 3

UI: 2,1-1 UT 2

Replacement SG's installed I RI 5 have no welds at structural discontinuities Replacement SG's installed I R 5 Replacement SG's installed IRI5, Scheduled per IWC-2412 Concurrent w/ Class I CH/TS U2:2.1-1 N/A N/A U2: 2.1-1 UT 3

U2: 2.1-1 UT 2

Replacement SG's installed 2R14 have no welds at structural discontinuities Replacement SG's installed 2R14 have no welds at structural discontinuities Replacement SG's installed 2R14, Scheduled per IWC-2412 Concurrent w/ Class I CH/TS Page 137

ASME Sec. Xl 98Catogory C-A IS PRGA PAN ITEM PARTS EXAMINED COMP/LINE WELD/COMP NO.

ISI DWG.

NDE PER.

LINE-RELIEF TOTL-%

REQ.

BLOCK NOTES C1 10 Shell Circumferential Welds C.20 Head Circumferential Welds CI 10 Shell Circumferential Welds C1.20 Head Circumferential Welds Seal Injection Filter I-1 Seal Injection Filter 1-I Seal Injection Filter 2-1 Seal Injection Filter 2-1 None None UI: 2.1-3 UI: 2.1-3 Complete Limitation Exoected Complete Limitation Exoected Complete Limitation Exoected Complete Limitation Exoected None None U2: 2.1-3 U2: 2.1-3 C 1. 10-1.30 Shell, Head and Tubesheet Welds See Note Excess Letdown &

Regenerative HXs N/A - See Note Excess Letdown and Regenerative Heat Exchangers (Unit I & 2) Exempt by IWC-1220.

Page 138

ASME Sec. XI Code Category C-A IS PRGAM PLAN Dial Canv 3r nevlRv ITEM PARTS EXAMINED COMP/LINE WELD/COMP NO.

ISI DWG.

NDE PER.

Cl 10 Shell Circumferential Welds C1.20 Head Circumferential Welds RHR Heat Exchanger Girth Weld GA (# 1) 1-1 (Shell-to-Flange)

RHR Heat Exchanger Girth Weld GD (#4) 1-2 (Head-to-Shell)

UI: 2.1-6 PT UI: 2.1-6 PT 2

3 LINE-RELIEF BLOCK TOTL-%

REQ.

Limitation Expected Limitation Expected NOTES C1.10 Shell Circumferential Welds C1.20 Head Circumferential Welds RHR Heat Exchanger Girth Weld Item 21 2-1 (Shell-to-Flange)

RHR Heat Exchanger Girth Weld Item 22 2-1 (Head-to-Shell)

U2:2.1-6 PT U2:2.1-6 PT 2

3 Limitation Expected Limitation Expected Page 139

ASME Sec. XI C 9

, Category C-B S

PRGAM PAN ITEM PARTS EXAMINED COMP/LINE WELD/COMP NO.

ISIDWG.

NDE PER.

LINE-RELIEF BLOCK TOTL-%

REQ.

NOTES C2.10 Nozzles in Vessles <1/2" wall thickness None: Items not applicable or exempt by IWC-1220 C2.21 Nozzles in Vessels >1/2" wall:

Nozzle-to-Shell Weld Nozzles in Vessels >1/2" wall:

Nozzle-to-Shell Weld Nozzles in Vessels >1/2" wall:

Nozzle-to-Shell Weld - None Nozzles in Vessels >1/2" wall:

Nozzle-to-Shell Weld - None C2.22 Nozzle Inside Radius Section RSG 1-3 to KI 6-557-161V RSG 1-3 to K16-557-161V RSG 1-4 to K15-225-28V RSG 1-4 to KI 5-225-28V RSG 1-3 to K16-557-161V RSG 1-4 to KI5-225-28V Feedwater Nozzle-to-Shell Weld UI: 2.1-1 UT 2

Ul:2.1-1 MT 2

Replacement Steam Generators installed I Rl15.

Feedwater Nozzle-to-Shell Weld (Main Steam Nozzle)

(Main Steam Nozzle)

Feedwater Nozzle Inside Radius (Main Steam Nozzle)

(Inside Radius)

Ul: 2.1-1 UI: 2.1-1 Ul:2.1-1 UT 2

RSG's steam outlet nozzles integrally formed with head. There is no steam outlet nozzle weld.

RSG's steam outlet nozzles integrally formed with head. There is no steam outlet nozzle weld.

RSG steam outlet design incorporates flow restrictor, does not have inner radius section.

  • Reliefreouest to be submitted if necessarv.

Replacement Steam Generators installed 2R14.

Nozzle Inside Radius Section -

None U: 2.1-1 See Note C2.21 Nozzles in Vessels >1/2" wall:

Nozzle-to-Shell Weld Nozzles in Vessels >1/2" wall:

Nozzle-to-Shell Weld Nozzles in Vessels >1/2" wall:

Nozzle-to-Shell Weld - None Nozzles in Vessels >1/2" wall:

Nozzle-to-Shell Weld - None C2.22 Nozzle Inside Radius Section RSG 2-1 to 2KI6-554-161V RSG 2-1 to 2K16-554-I61V RSG 2-1 to 2KI5-228-28V RSG 2-1 to 2K15-228-28V RSG 2-1 to 2KI6-554-161V RSG 2-1 to 2KI 5-228-28V Feedwater Nozzle-to-Shell Weld U2: 2.1-1 UT 2

U2:2.1-1 MT 2

Feedwater Nozzle-to-Shell Weld (Main Steam Nozzle)

(Main Steam Nozzle)

Feedwater Nozzle Inside Radius (Main Steam Nozzle)

(Inside Radius)

U2: 2.1-1 U2: 2.1-1 RSG's steam outlet nozzles integrally formed with head. There is no steam outlet nozzle weld.

RSG's steam outlet nozzles integrally formed with head. There is no steam outlet nozzle weld.

RSG steam outlet design incorporates flow restrictor, does not have inner radius section.

  • Reliefreauest to be submitted if necessary.

U2:2.1-1 UT 2

Nozzle Inside Radius Section -

None U2: 2.1-1 See Note Page 140

ASME Sec. XA Category C-B IS PROGRAMPLA ITEM PARTS EXAMINED COMP/LINE WELD/COMP NO.

ISI DWG.

NDE PER.

LINE-RELIEF TOTL-%

REQ.

BLOCK NOTES C2.21 Nozzles in Vessels >1/2" wall:

Nozzle-to-Shell Weld C2.22 Nozzle Inside Radius Section C2.21 Nozzles in Vessels >1/2" wall:

Nozzle-to-Shell Weld C2.22 Nozzle Inside Radius Section UI Seal Inj Filter U1 Seal Inj Filter U2 Seal Inj Filter U2 Seal Inj Filter Nozzle-to-Shell Welds Nozzles Inside Radius Section Nozzle-to-Shell Welds Nozzles Inside Radius Section UI: 2.1-3 None UI: 2.1-3 None U2:2.1-3 None U2:2.1-3 None Complete Limitation Exoected Complete Limitation Expected Complete Limitation Exoected Complete Limitation Exoected Inlet and Outlet. Not normally isolated from "high pressure safety injection system" Inlet and Outlet. Not normally isolated from "high pressure safety injection system" Inlet and Outlet. Not normally isolated from "high pressure safety injection system" Inlet and Outlet. Not normally isolated from "high pressure safety injection system" C2.21 Nozzles in Vessels >1/2" wall:

See Note Nozzle-to-Shell Weld Excess Letdown &

Regenerative HX)s Excess Letdown &

Regenerative HX's N/A - See Note N/A - See Note Excess Letdown and Regenerative Heat Exchangers (Unit I & 2) Exempt IWC-1220.

Excess Letdown and Regenerative Heat Exchangers (Unit I & 2) Exempt IWC-1220.

C2.22 See Note Nozzle Inside Radius Section Page 141

ASME Sec. XI Code Category C-B S

PRGAM PAN ITEM PARTS EXAMINED COMP/LINE WELD/COMP NO.

ISI DWG.

NDE PER.

LINE-RELIEF BLOCK TOTL-%

REQ.

NOTES C2.21 Nozzles in Vessels >1/2" wall:

Nozzle-to-Shell Weld Nozzles in Vessels >1/2" wall:

Nozzle-to-Shell Weld C2.22 Nozzle Inside Radius Section Nozzle Inside Radius Section C2.21 Nozzles in Vessels >1/2" wall:

Nozzle-to-Shell Weld Nozzles in Vessels >1/2" wall:

Nozzle-to-Shell Weld C2.22 Nozzle Inside Radius Section Nozzle Inside Radius Section RHR HX 1-1 to SI-112-8 RHR HX 1-2 to SI-119-8 RHR HX 1-1 to SI-112-8 RHR HX 1-2 to SI-119-8 RHR HX 2-1 to 2Sl-112-8 RHR HX 2-1 to 2S1-3551-14 RHR HX 2-1 to 2S1-112-8 RHR IX 2-1 to 2SI-3551-14 Inlet Nozzle-to-Shell Weld #5 (NI)

Outlet Nozzle-to-Shell Weld #6 (N2)

Inlet Nozzle #5 (N 1)

Inside Radius Outlet Nozzle #6 (N2)

Inside Radius Inlet Nozzle-to-Shell Weld Item 24 Outlet Nozzle-to-Shell Weld Item 23 Inlet Nozzle Inside Radius @ Item 24 Outlet Nozzle Inside Radius @ Item 23 UI: 2.1-6 PT 2

UI: 2.1-6 PT 3

U 1: 2.1-6 None UI: 2.1-6 None U2:2.1-6 PT 2

U2:2.1-6 PT 3

U2:2.1-6 None U2:2.1-6 None Limitation Expected Limitation Expected Complete Limitation Exoected Complete Limitation Exoected Limitation Expected Limitation Expected Complete Limitation Exoected Complete Limitation Exoected Page 142

ASME Sec. XI Code Category C-C IS PRGAM.

PAN ITEM PARTS EXAMINED COMP/LINE WELD/COMP NO.

ISI DWG.

NDE PER. LINE-TOTL RELIEF REQ.

NOTES C3.10 Note See Pressure Vessels Welded Attachments Excess Letdown &

Regenerative HX's N/A - See Note Excess Letdown and Regenerative Heat Exchangers (Unit I & 2) Exempt by IWC-1220.

C3.10 Pressure Vessels Welded Attachments Steam Generators (Unit 1)

None Ul: 2.1-1 Belly Band Locating Struts position band, do not support SG. No exam required.

Pressure Vessels Welded Attachments Seal Injection Filter 1-1 Support Leg Attachment UI: 2.1-3 VT-3*

I Submittal Not normally isol from "h.p. safety injection".

Pending Examination Also Required if Deformation of SUtoort Member Seen At Anv Time Pressure Vessels Welded Attachments RHR Heat Exchanger 1-1 Support Leg LA Attachment UI: 2.1-6 PT Examination Also Required if Deformation of Support Member Seen At Any Time C3.10 Pressure Vessels Welded Attachments Steam Generators (Unit 2)

None U2: 2.1-1 Belly Band Locating Struts do not support SG.

No exam required.

Pressure Vessels Welded Attachments Seal Injection Filter 2-1 Support Leg Attachment U2:2.1-3 VT-3*

I Submittal Not normally isol from "h.p. safety injection".

Pending Examination Also Required if Deformation of Sunnort Member Seen At Anv Time Pressure Vessels Welded Attachments RHR Heat Exchanger 2-1 Support Leg Attachment no. 19 (front)

U2:2.1-6 PT I

Examination Also Required if Deformation of Support Member Seen At Any Time Page 143

ASME Sec. Xl Code Category C-C IS PROGRAM PLAN DiaboCno r

nevlRv ITEM PARTS EXAMINED COMP/LINE WELD/COMP NO.

ISI DWG.

NDE PER. LINE-TOTL RELIEF REQ.

NOTES C3.20--

Piping Unit 1 Welded Attachments:

Loop 4 Hot Leg to RHR Pps.

Welded Attachment Loop 4 Hot Leg to RHR Pps.

Welded Attachment RHR Ppl -1 Suction. Welded Attachment RHR Ppl -1 Suction. Welded Attachment RHR Ppl -2 Suction. Welded Attachment RHR Ppl -2 Suction. Welded Attachment RHR Ht Exchr 1-1 Outlet.

Welded Attachment RHR Ht Exchr 1-1 Outlet.

Welded Attachment RHR Ht Exchr 1-1 Outlet.

Welded Attachment RHR Supply to Spray Hdrs 1 & 3.

Welded Attachment RHR Supply to Spray Hdrs 1 & 3.

Welded Attachment RHR Supply to Spray Hdrs 1 & 3.

Welded Attachment RHR to Charging Pps. Suction.

Welded Attachment NOTE: Only lines with welded attachments are listed:

Line S 1-927-14111 Line S 1-927-1411I Line S 1-110-14111 Line SI-110-14I11 Line SI-111-141H Line SI-111-14411 Line S1-3551-141II Line S1-118-811i Line S I-118-8111 Line S 1-279-81IP Line S 1-279-8111P Line SI-279-8111P Line S 1-734-8111P 12-7SL Attach.

57S-20V Attach.

Paramount 57S-21V'Attach.

55S-90A Attach.

57S-22V Attach 55S-91A Attach.

288-11 R Attach.

4-4SL Attach.

288-61R Attach.

55S-81A Attach.

55S-128V Attach.

57S-70V Attach.73-25R Attach.

UI: 2.2-1 PT U 1: 2.2-2 PT UI: 2.2-2 PT UI: 2.2-2 PT UI: 2.2-2 PT U 1: 2.2-2 PT UI: 2.2-3 PT U1: 2.2-3 PT 10% of Piping Welded Attachments Req'd Regardless of Attachment Thickness Examination Also Required if Deformation of Support Member Seen At Any Time Examination Also Required if Deformation of Support Member Seen At Any Time

  • Examination Required if Deformation of Support Member Seen At Any Time
  • Examination Required if Deformation of Support Member Seen At Any Time
  • Examination Required if Deformation of Support Member Seen At Any Time
  • Examination Required if Deformation of Support Member Seen At Any Time
  • Examination Required if Deformation of Support Member Seen At Any Time
  • Examination Required if Deformation of Support Member Seen At Any Time
  • Examination Required if Deformation of Support Member Seen At Any Time
  • Examination Required if Deformation of Support Member Seen At Any Time
  • Examination Required if Deformation of Support Member Seen At Any Time
  • Examination Required if Deformation of Support Member Seen At Any Time
  • Examination Required if Deformation of Support Member Seen At Any Time U 1: 2.2-3 PT Ut: 2.2-3 Uh: 2.2-3 PT PT U 1: 2.2-3 PT UhL 2.2-3 PT Page 144

ASME Sec. A Category C-C IS POGA PLANA ITEM PARTS EXAMINED COMP/LINE WELD/COMP NO.

ISI DWG.

NDE PER. LINE-TOTL RELIEF REQ.

NOTES C3.20 SIS to RCS Hot Leg Loop 1.

Cont'd Welded Attachment RHR Injection to Hot Leg 1&2.

Welded Attachment RHR Injection to Hot Leg 1&2.

Welded Attachment RHR Injection to Hot Leg 1&2.

Welded Attachment RHR Injection to Hot Leg I &2.

Welded Attachment RHR Injection to Hot Leg 1&2.

Welded Attachment RHR Injection to Hot Leg l&2.

Welded Attachment RHR Injection to Hot Leg 1&2.

Welded Attachment RHR Injection to Hot Leg 1&2.

Welded Attachment RHR Pp 1-1 Disch. Welded Attachment RHR Pp 1-1 Disch. Welded Attachment RHR Heat Exchr Bypass Crosstie.

Welded Attachment RHR Heat Exchr Bypass Crosstie.

Welded Attachment RHR Heat Exchr Bypass Crosstie.

Welded Attachment Line S6-2575-8 Line S 1-985 -12111P Line S 1-985-12111P Line SI-985-12111P Line S 1-985-121lIP Line S I-985-12111P Line SI-985-12111P Line SI-985-12IIIP Line S 1-985-12111P Line SI-112-8111 Line SI-112-8111 Line S I-1663-8111 Line SI-1663-8111 Line S 1-1663-8111 40-26V Attach.

10-35SL Attach.

10-39SL Attach.40-46A Attach. X219 10-18SL Attach.

10-19SL Attach.

40-SOR Attach.40-47R Attach.

57S-24V Attach.

4-8R Attach.

72-6R (Location 1)

Attach.

4-7SL Attach.

72-1A Attach.

4-51 SL Attach.

UI: 2.2-4 UI: 2.2-4 Ut: 2.2-4 UI: 2.2-5 UI: 2.2-5 Ut: 2.2-5 UI: 2.2-5 UI: 2.2-5 UI: 2.2-7 U I: 2.2-9A UI: 2.2-9A UI: 2.2-9A UI: 2.2-9A U 1: 2.2-9B PT PT PT PT PT PT PT PT PT PT PT PT PT PT

  • Examination Required if Deformation of Support Member Seen At Any Time
  • Examination Required if Deformation of Support Member Seen At Any Time
  • Examination Required if Deformation of Support Member Seen At Any Time Examination Also Required if Deformation of Support Member Seen At Any Time
  • Examination Required if Deformation of Support Member Seen At Any Time
  • Examination Required if Deformation of Support Member Seen At Any Time
  • Examination Required if Deformation of Support Member Seen At Any Time
  • Examination Required if Deformation of Support Member Seen At Any Time
  • Examination Required if Deformation of Support Member Seen At Any Time
  • Examination Required if Deformation of Support Member Seen At Any Time
  • Examination Required if Deformation of Support Member Seen At Any Time
  • Examination Required if Deformation of Support Member Seen At Any Time
  • Examination Required if Deformation of Support Member Seen At Any Time
  • Examination Required if Deformation of Support Member Seen At Any Time Page 145

ASME See. Xl Code Category C-C ISI PRGAM PLAN ITEM PARTS EXAMINED COMP/LINE WELD/COMP NO.

ISI DWG.

NDE PER. LINE-TOTL RELIEF REQ.

NOTES C3.20 RHR Pp 1-2 Disch. Welded Cont'd Attachment RHR Pp 1-2 Disch. Welded Attachment RHR Heat Exchrs. Bypass Header. Welded Attachment RHR Heat Exchrs. Bypass Header. Welded Attachment RHR I Ieat Exchrs. Bypass Header. Welded Attachment RHR Heat Exchrs. Bypass Header. Welded Attachment RHR Heat Exchrs. Bypass Header. Welded Attachment Cent'l Chg Pps Disch Header.

Welded Attachment Cent'l Chg Pps Disch Header.

Welded Attachment Cont. Sump to RHR Pp. t-1 Suet.

Welded Attachment Cont. Sump to RHR Pp. 1-1 Suct.

Welded Attachment Cont. Sump to RHR Pp.1-2 Suet.

Welded Attachment Cont. Sump to RHR Pp. 1-2 Suet.

Welded Attachment Residual Ht. Exchr. 1-1 Outlet.

Welded Attachment.

Line S1 -113-8111 Line SI-113-8111 Line S I - 1661-8I11 Line SI-1661-81II Line S I - 1661-8111 Line S 1 - 1661-81II Line S 1 - 1661-811I Line SI-1454-6 Line S1-1454-6 Line SI-512-14111P Line S 1-5 12-14111P Line SI -513-14111P Line SI -513-14111P Line SI-118-81II 72-5V Attach.

72-6R (Location 2)

Attach.

72-4V Attach.72-38R Attach.

72-3V Attach.74-32R Attach.74-29A Attach.73-36R Attach. Lugs 54S-16R Attach.

54S-3A Attach.72-12R (Location A)

Attach.

54S-4A Attach.72-12R (Location B)

Attach.

288-59A Attach.

U 1: 2.2-9B PT UI: 2.2-9B PT U 1: 2.2-9B PT U 1: 2.2-9B PT UI: 2.2-9B PT UI: 2.2-9B PT U 1: 2.2-9B PT UI: 2.2-10 PT UI: 2.2-10 PT U1:2.2-11 PT UI: 2.2-11 PT U1: 2.2-12 PT UI: 2.2-12 PT U1: 2.2-13 PT

  • Examination Required if Deformation of Support Member Seen At Any Time
  • Examination Required if Deformation of Support Member Seen At Any Time
  • Examination Required if Deformation of Support Member Seen At Any Time
  • Examination Required if Deformation of Support Member Seen At Any Time
  • Examination Required if Deformation of Support Member Seen At Any Time
  • Examination Required if Deformation of Support Member Seen At Any Time
  • Examination Required if Deformation of Support Member Seen At Any Time
  • Examination Required if Deformation of Support Member Seen At Any Time
  • Examination Required if Deformation of Support Member Seen At Any Time
  • Examination Required if Deformation of Support Member Seen At Any Time
  • Examination Required if Deformation of Support Member Seen At Any Time
  • Examination Required if Deformation of Support Member Seen At Any Time
  • Examination Required if Deformation of Support Member Seen At Any Time
  • Examination Required if Deformation of Support Member Seen At Any Time Page 146

ASME Sec. XI Code Category C-C ISI PRGAM PLAN ITEM PARTS EXAMINED COMP/LINE WELD/COMP NO.

ISI DWG.

NDE PER. LINE-TOTL RELIEF REQ.

NOTES C3,20 Residual Ht. Exchr. 1-2 Outlet.

Cont'd Welded Attachment.

RHR Pp. Inj. Cold Leg Pp.1-2.

Welded Attachment Cent. Charg. Pump 1-1 Suct.

Welded Attachment Cent. Charg. Pump 1-1 Suct.

Welded Attachment RHR Supply to Spray Hdrs 2 & 4.

Welded Attachment RHR to SIS Pp. 1-2 & Cont.

Spray. Welded Attachment RHR to SIS Pp. 1-2 & Cont.

Spray. Welded Attachment RHR to Safety Injection Pump Welded Attachment RHR to Safety Injection Pump Welded Attachment RHR to Safety Injection Pump Welded Attachment Safety Inij. Pp.1-I Suction.

Welded Attachment Safety Inj. Pp. 1-2 Suction.

Welded Attachment Safety Inj. Pumps Suction Header.

Welded Attachment Charging Injection Inlet. Welded Attachment Line SI-119-8111 Line S I-119-8111 Line S2-42-6 Line S2-42-6 Line S 1-280-8111P Line S1-735-8111P Line S 1-735-8111P Line S2-1984-8 Line S2-1984-8 Line S2-1984-8 Line S2-1982-6 Line S2-1983-6 Line S2-1986-8 Line S6-2032-6 288-58A Attach.

56S-18V Attach.73-20R Attach.73-24R Attach.

58S-159R Attach.

56S-26R Attach.

55S-86A Attach.

56S-29A Attach.

56S-27R Attach.98-39A Attach.98-14R Attach.98-29R Attach.

98-3A Attach.

54S-11V Attach.

U1: 2.2-14 PT UI: 2.2-14 PT UI: 2.2-15 PT Ul: 2.2-15 PT UI: 2.2-16 PT U1: 2.2-16 PT UI: 2.2-16 PT UI: 2.2-17 PT U1: 2.2-17 PT UI: 2.2-17 PT UI: 2.2-18 PT UI: 2.2-18 PT U1: 2.2-18 PT UI: 2.2-19 PT

  • Examination Required if Deformation of Support Member Seen At Any Time
  • Examination Required if Deformation of Support Member Seen At Any Time
  • Examination Required if Deformation of Support Member Seen At Any Time
  • Examination Required if Deformation of Support Member Seen At Any Time
  • Examination Required if Deformation of Support Member Seen At Any Time
  • Examination Required if Deformation of Support Member Seen At Any Time
  • Examination Required if Deformation of Support Member Seen At Any Time
  • Examination Required if Deformation of Support Member Seen At Any Time
  • Examination Required if Deformation of Support Member Seen At Any Time
  • Examination Required if Deformation of Support Member Seen At Any Time
  • Examination Required if Deformation of Support Member Seen At Any Time
  • Examination Required if Deformation of Support Member Seen At Any Time
  • Examination Required if Deformation of Support Member Seen At Any Time
  • Examination Required if Deformation of Support Member Seen At Any Time Page 147

ASME Sec. XI Code Category C-C IS PRGAM PLAN ITEM PARTS EXAMINED COMP/LINE WELD/COMP NO.

ISI DWG.

NDE PER. LINE-TOTL RELIEF REQ.

NOTES C3.20 Crosstie Chg. Pp. & SI Pp.

Cont'd Suction. Welded Attachment RHR to Safety Injection Pp. 1-1.

Welded Attachment RHR to SI Pp Suct Void Header.

Welded Attachment Steam Gen Steam Outlet 1-I.

Welded Attachment Steam Gen Steam Outlet 1-1.

Welded Attachment Steam Gen Steam Outlet 1-1.

Welded Attachment Steam Gen Steam Outlet 1-1.

Welded Attachment Steam Gen Steam Outlet 1-2.

Welded Attachment Steam Gen Steam Outlet 1-2.

Welded Attachment Steam Gen Steam Outlet 1-2.

Welded Attachment Steam Gen Steam Outlet 1-2.

Welded Attachment Steam Gen Steam Outlet 1-3.

Welded Attachment Steam Gen Steam Outlet 1-3.

Welded Attachment Main Steam Lead 3 Relief VIv.

Hdr. Welded Attachment Line S2-4296-6 Line S2-5848-6 Line S2-7077-18 Line K15-228-28V Line KI 5-228-28V Line K 15-228-28V Line KI5-228-28V Line K15-227-28V Line K 15-227-28V Line K15-227-28V Line K 15-227-28V Line K15-226-28V Line K15-226-28V Line KI 5-1065-24V 74-42A Attach.

98-129R Attach.

288-158A Attach.

1020-1V Attach. Lugs 1032-3R Attach.

1032-16R Attach.

102 1-11R Attach.

1022-1V Attach. Lugs 1023-11 R Attach.

1032-15R Attach.

1032-4R Attach.

1026-IV Attach. Lugs 1033-3SL Attach.

1027-8V (& 1033-15SL)

Attach.

Ut: 2.2-20 PT UI: 2.2-20 PT U 1: 2.2-20 PT UI: 2.2-21 MT I

UI: 2.2-21 MT Ut: 2.2-21 MT Ut: 2.2-21 MT UI: 2.2-22 MT 2

  • Examination Required if Deformation of Support Member Seen At Any Time
  • Examination Required if Deformation of Support Member Seen At Any Time
  • Examination Required if Deformation of Support Member Seen At Any Time Examination Also Required if Deformation of Support Member Seen At Any Time
  • Examination Required if Deformation of Support Member Seen At Any Time
  • Examination Required if Deformation of Support Member Seen At Any Time
  • Examination Required if Deformation of Support Member Seen At Any Time Examination Also Required if Deformation of Support Member Seen At Any Time
  • Examination Required if Deformation of Support Member Seen At Any Time
  • Examination Required if Deformation of Support Member Seen At Any Time
  • Examination Required if Deformation of Support Member Seen At Any Time Examination Also Required if Deformation of Support Member Seen At Any Time
  • Examination Required if Deformation of Support Member Seen At Any Time
  • Examination Required if Deformation of Support Member Seen At Any Time UI: 2.2-22 MT Ut: 2.2-22 MT UI: 2.2-22 MT U 1: 2.2-23 MT 3

Ut: 2.2-23 MT U 1: 2.2-23 MT Page 148

ASME Sec. XlO Category C-C II P ROGAMLANA ITEM PARTS EXAMINED COMP/LINE WELD/COMP NO.

ISI DWG.

NDE PER. LINE-TOTL RELIEF REQ.

NOTES C3.20 Main Steam Lead 3 Relief Vlv.

Cont'd Hdr. Welded Attachment Main Steam Lead 3 Relief Vlv.

Hdr. Welded Attachment Steam Gen Steam Outlet 1-4.

Welded Attachment Steam Gen Steam Outlet 1-4.

Welded Attachment Steam Gen Steam Outlet 1-4.

Welded Attachment Steam Gen Steam Outlet 1-4.

Welded Attachment Main Steam Lead 4 Relief Vlv.

Hdr. Welded Attachment Main Steam Lead 4 Relief Vlv.

Hdr. Welded Attachment Main Steam Lead 4 Relief Vlv.

Hdr. Welded Attachment Stm Gen Feedwater Supply I-1.

Welded Attachment Stm Gen Feedwater Supply 1-1.

Welded Attachment Stm Gen Feedwater Supply 1-1.

Welded Attachment Stm Gen Feedwater Supply 1-1.

Welded Attachment Stm Gen Feedwater Supply 1-2.

Welded Attachment Line KI5-1065-24V Line K15-1065-24V Line K15-225-28V Line K15-225-28V Line K15-225-28V Line Kt 5-225-28V Line K 15-1066-24V Line K15-1066-24V Line K 15-1066-24V Line K16-554-16V Line K16-554-16V Line K16-554-16V Line K16-554-16V Line K16-555-16V 1030-14R Attach.

1033-27R Attach.

1028-1V Attach. Lugs 1029-IV Attach.

1031 -16R Attach.

1033-4SL Attach.

1029-8V (& 1033-16SL)

Attach.

103 1-11R Attach.

1033-28SL Attach.

1037-7V Attach.

Paramount 1048-15R Attach.

1048-14R Attach.

1048-IR Attach.

1039-9V Attach.

Paramount U 1: 2.2-23 MT U 1: 2.2-23 MT U 1: 2.2-24 MT 3

U 1: 2.2-24 MT Ut: 2.2-24 MT UI: 2.2-24 MT Ut: 2.2-24 MT Ut: 2.2-24 MT UI: 2.2-24 MT Ut: 2.2-25 MT I

UI: 2.2-25 MT Ut: 2.2-25 MT U 1: 2.2-25 MT Ut: 2.2-26 MT 3

  • Examination Required if Deformation of Support Member Seen At Any Time
  • Examination Required if Deformation of Support Member Seen At Any Time Examination Also Required if Deformation of Support Member Seen At Any Time
  • Examination Required if Deformation of Support Member Seen At Any Time
  • Examination Required if Deformation of Support Member Seen At Any Time
  • Examination Required if Deformation of Support Member Seen At Any Time
  • Examination Required if Deformation of Support Member Seen At Any Time
  • Examination Required if Deformation of Support Member Seen At Any Time
  • Examination Required if Deformation of Support Member Seen At Any Time Examination Also Required if Deformation of Support Member Seen At Any Time
  • Examination Required if Deformation of Support Member Seen At Any Time
  • Examination Required if Deformation of Support Member Seen At Any Time
  • Examination Required if Deformation of Support Member Seen At Any Time Examination Also Required if Deformation of Support Member Seen At Any Time Page 149

ASME Sec. XI Code Category C-C ISI PRGAM PLAN ITEM PARTS EXAMINED COMP/LINE WELD/COMP NO.

151 DWG.

NDE PER. LINE-TOTL RELIEF NOTES REQ.

C3.20 Stm Gen Feedwater Supply 1-2.

Cont'd Welded Attachment Stm Gen Feedwater Supply 1-2.

Welded Attachment Stm Gen Feedwater Supply 1-2.

Welded Attachment Stm Gen Feedwater Supply 1-3.

Welded Attachment Stm Gen Feedwater Supply 1-3.

Welded Attachment Stm Gen Feedwater Supply 1-4.

Welded Attachment Stm Gen Feedwater Supply 1-4.

Welded Attachment Stm Gen Feedwater Supply 1-4.

Welded Attachment Chg. Pps. Suet. From RWST Viv.

A. Welded Attachment Chg. Pps. Suct. From RWST Viv.

A. Welded Attachment Chg. Pps. Suct. From RWST Viv.

B. Welded Attachment Chg. Pps. Suet. From RWST Viv.

B. Welded Attachment RHR Pp 1-1 Inj Cold Leg l&2.

Welded Attachment RHR Pp 1-1 Inj Cold Leg l&2.

Welded Attachment Line K16-555-16V Line K16-555-16V Line K16-555-16V Line K16-557-16V Line K16-557-16V Line K16-556-16V Line K16-556-16V Line K16-556-16V Line S2-1987-8 Line S2-1987-8 Line S2-1988-8 Line S2-1988-8 Line S6-508-8111 Line S6-508-8111 1048-12R Attach.

1048-11 OR Attach.

1048-2R Attach.

1042-9V Attach.

Paramount 1049-1 SL Attach.

1044-7V Attach.

Paramount 1049-4SL Attach.

1044-1V Attach.

74-6A Attach.

74-7R Attach.

4-96R Attach.

56S-25A Attach.

58N-49R Attach.

X307A-B 58N-52A Attach.

X426A-C U I: 2.2-26 MT UI: 2.2-26 MT Ut: 2.2-26 MT Ut: 2.2-27 MT 3

U: 2.2-27 MT Ut: 2.2-28 MT 2

Ut: 2.2-28 MT Ut: 2.2-28 MT Ut: 2.2-29 PT Ut: 2.2-29 PT U 1: 2.2-29 PT Ut: 2.2-29 PT UI: 2.2-31 PT 3

Ul: 2.2-31 PT 3

  • Examination Required if Deformation of Support Member Seen At Any Time
  • Examination Required if Deformation of Support Member Seen At Any Time
  • Examination Required if Deformation of Support Member Seen At Any Time Examination Also Required if Deformation of Support Member Seen At Any Time
  • Examination Required if Deformation of Support Member Seen At Any Time Examination Also Required if Deformation of Support Member Seen At Any Time
  • Examination Required if Deformation of Support Member Seen At Any Time
  • Examination Required if Deformation of Support Member Seen At Any Time
  • Examination Required if Deformation of Support Member Seen At Any Time
  • Examination Required if Deformation of Support Member Seen At Any Time
  • Examination Required if Deformation of Support Member Seen At Any Time
  • Examination Required if Deformation of Support Member Seen At Any Time Examination Also Required if Deformation of Support Member Seen At Any Time Examination Also Required if Deformation of Support Member Seen At Any Time Page 150
  • 0 ASME Sec. Xl Code Category C-C ISI PR GAM LA NA ITEM PARTS EXAMINED COMP/LINE WELD/COMP NO.

ISI DWG.

NDE PER. LINE-TOTL RELIEF REQ.

NOTES C3.20 RHR Pp 1-1 Inj Cold Leg l&2.

Cont'd Welded Attachment RHR Pp 1-1 Inj Cold Leg 1&2.

Welded Attachment RHR Pp 1-2 Inj Cold Leg l&2.

Welded Attachment RHR Pp 1-2 lnj Cold Leg l&2.

Welded Attachment RHR Pp 1-2 lnj Cold Leg l&2.

Welded Attachment RHR Pp I-I Inj Cold Leg 1:

Welded Attachment RHR Pp 1-1 Inj Cold Leg 2.

Welded Attachment RHR Pp 1-I Inj Cold Leg 2.

Welded Attachment RHR Pp 1-2 Inj. Cold Leg.

Welded Attachment Cent Chg Pp 1-1 Discharge.

Welded Attachment Cent Chg Pp 1-1 Discharge.

Welded Attachment Charging Pp 1-1 Bypass to Seal Inj. Welded Attachment Cent Chg Pps Disch Hdr. Welded Attachment Cent Chg Pps Disch Hdr. Welded Attachment Line S6-508-8III Line $6-508-811I Line S6-509-8I1 Line S6-509-8111 Line S6-509-8111 Line S6-3844-6t11 Line S6-3845-6SPL Line S6-3845-6SPL Line S6-3847-6SPL Line S6-45-4 Line S6-45-4 Line S6-1474-3 Line S6-3678-3 Line S6-3678-3 11 -35SL Attach.

I 1-37SL Attach.

57N-5R Attach.

Paramount 58N-55A Attach.

58N-54V Attach.42-37A Attach.

X394A-E 42-92R Attach.42-60R Attach.

58N-58V Attach.73-35R Attach. Lugs73-85A Attach.73-40R Attach.

54S-17R Attach. Lugs73-47A Attach.

U 1: 2.2-32 UI: 2.2-32 Ut: 2.2-33 UI: 2.2-33 UI: 2.2-33 UI: 2.2-34 Ut: 2.2-35 UI: 2.2-35 Ut: 2.2-36 UI: 2.2-38 Ut: 2.2-38 UI: 2.2-39 UI: 2.2-40 UI: 2.2-40 PT PT PT PT PT PT PT PT PT PT PT PT PT PT 2

  • Examination Required if Deformation of Support Member Seen At Any Time
  • Examination Required if Deformation of Support Member Seen At Any Time Examination Also Required if Deformation of Support Member Seen At Any Time
  • Examination Required if Deformation of Support Member Seen At Any Time
  • Examination Required if Deformation of Support Member Seen At Any Time Examination Also Required if Deformation of Support Member Seen At Any Time
  • Examination Required if Deformation of Support Member Seen At Any Time
  • Examination Required if Deformation of Support Member Seen At Any Time
  • Examination Required if Deformation of Support Member Seen At Any Time Examination Also Required if Deformation of Support Member Seen At Any Time
  • Examination Required if Deformation of Support Member Seen At Any Time
  • Examination Required if Deformation of Support Member Seen At Any Time Examination Also Required if Deformation of Support Member Seen At Any Time
  • Examination Required if Deformation of Support Member Seen At Any Time I

Page 151

ASME Sec. Xl Code Category C-C S

PRGAM PAN Diablo Cayn r

Intra e.1 ITEM PARTS EXAMINED COMP/LINE WELD/COMP NO.

ISI DWG.

NDE PER. LINE-TOTL RELIEF NOTES S%

REQ.

C3.20 Cent Chg Pp 1-2 Disch. Welded Cont'd Attachment Charg Pp 1-2 BP Sup to Seal Inj.

Welded Attachment Recip Chg Pp 1-3 Disch.

Welded Attachment Recip Chg Pp 1-3 Disch.

Welded Attachment Regen HX Inlet Chg Line to V-8108 Regen HX Inlet Chg Line to V-8108 Regen HX Inlet Chg Line to V-8108 Regen HX Inlet Chg Line to V-8108 Regen HX Inlet Chg Line to V-8108 Regen HX Inlet Chg Line to V-8108 Regen HX Inlet Chg Line to V-8108 Charging Pps Disch Emerg 2.

Welded Attachment Charging Injection Out Welded Attachment Charging Injection Out Header Welded Attachment Line S6-46-4 S6-1475-3 Line S6-47-3 Line S6-47-3 Line S6-48-3 Line S6-48-3 Line S6-48-3 Line S6-48-3 Line S6-48-3 Line S6-48-3 Line S6-48-3 Line S6-1975-4 Line S6-2033-4 Line S6-1016-3 73-87A Attach.73-37R Attach. Lugs73-48A Attach. Gusset 73-50R Attach. Lugs 55S-125R Attach.

55S-123R Attach.

55S-I 18A Attach.

99-187V Attach.99-33A Attach.

99-8 1R Attach.74-27A Attach.

54S-13R Attach.

288-4A Attach.

57S-123V Attach. Lugs UI: 2.2-41 U 1: 2.2-42 UI: 2.243 U1: 2.243 UI: 2.2-44 UI: 2.2-44 Ut: 2.2-44 Ul: 2.2-44 U 1: 2.2-44 Ul: 2.2-44 Ul: 2.2-44 Ut: 2.247 Ut: 2.248 Ul: 2.2-53 PT PT PT PT PT PT PT PT PT PT PT PT PT PT

  • Examination Required if Deformation of Support Member Seen At Any Time Examination Also Required if Deformation of Support Member Seen At Any Time Examination Also Required if Deformation of Support Member Seen At Any Time Examination Also Required if Deformation of Support Member Seen At Any Time
  • Examination Required if Deformation of Support Member Seen At Any Time
  • Examination Required if Deformation of Support Member Seen At Any Time
  • Examination Required if Deformation of Support Member Seen At Any Time
  • Examination Required if Deformation of Support Member Seen At Any Time
  • Examination Required if DHformation of Support Member Seen At Any Time
  • Examination Required if Deformation of Support Member Seen At Any Time
  • Examination Required if Deformation of Support Member Seen At Any Time
  • Examination Required if Deformation of Support Member Seen At Any Time
  • Examination Required if Deformation of Support Member Seen At Any Time Examination Also Required if Deformation of Support Member Seen At Any Time 1

Page 152

ASME Sec. Xli Category C-C ITEM PARTS EXAMINED COMP/LINE WELD/COMP NO.

ISI DWG.

NDE PER. LINE-TOTL RELIEF REQ.

NOTES C3.20 Charging Pps Disch Header Cont'd Welded Attachment Charging Pps Disch Header Welded Attachment Charging Pps Seal Supply Welded Attachment Charging Pps Seal Supply Welded Attachment CVCS Seal lnj Filter 1-2 Inlet Welded Attachment CVCS Seal lnj Filter 1-2 Outlet Welded Attachment CVCS Seal Inj Filter I-I Inlet Welded Attachment CVCS Seal Inj Filter 1-1 Outlet Welded Attachment RX Coolant Pps Seal Water In Welded Attachment RX Coolant Pps Seal Water In Welded Attachment Charg Pp 1-2 Bypass Miniflow Welded Attachment Cent Chg Pps Byp Miniflow Hdr.

Welded Attachment RC Pump I-I Seal Water Inlet Welded Attachment RC Pump I-I Seal Water Inlet Welded Attachment Line S6-52-3 Line S6-52-3 Line S6-53-3 Line S6-53-3 Line S6-2047-3 Line S6-2048-3 Line S6-2044-3 Line S6-2046-3 Line S6-746-3 Line S6-746-3 Line S6-1468-2 Line S6-1464-2 Line S6-54-2 Line S6-54-2 99-74A Attach.

99-9R Attach.73-45A Attach.74-30A Attach.

512-8R Attach.

512-7R Attach.

512-6R Attach.

512-6R Attach.99-25R Attach.

57S-1 12A Attach.

73-23 Attach.

73-24 Attach.

2155-74 Attach.

55N-9R Attach.

UI: 2.2-54 PT UI: 2.2-54 PT UI: 2.2-55 PT Ul: 2.2-55 PT UI: 2.2-56 PT UI: 2.2-58 PT U 1: 2.2-59 PT U1: 2.2-60 PT U1: 2.2-61 PT UI: 2.2-61 PT Ut: 2.2-64 PT UI: 2.2-65 PT U1: 2.2-74 PT UI: 2.2-74 PT

  • Examination Required if Deformation of Support Member Seen At Any Time
  • Examination Required if Deformation of Support Member Seen At Any Time
  • Examination Required if Deformation of Support Member Seen At Any Time
  • Examination Required if Deformation of Support Member Seen At Any Time
  • Examination Required if Deformation of Support Member Seen At Any Time
  • Examination Required if Deformation of Support Member Seen At Any Time
  • Examination Required if Deformation of Support Member Seen At Any Time
  • Examination Required if Deformation of Support Member Seen At Any Time
  • Examination Required if Deformation of Support Member Seen At Any Time
  • Examination Required if Deformation of Support Member Seen At Any Time
  • Examination Required if Deformation of Support Member Seen At Any Time
  • Examination Required if Deformation of Support Member Seen At Any Time
  • Examination Required if Deformation of Support Member Seen At Any Time
  • Examination Required if Deformation of Support Member Seen At Any Time Page 153

ASME Sec. XI Code Category C-C IS POGA PLANA ITEM PARTS EXAMINED COMP/LINE WELD/COMP NO.

IS% DWG.

NDE PER. LINE-TOTL RELIEF NOTES REQ.

C3.20 RC Pump 1-I Seal Water Inlet Cont'd Welded Attachment RC Pump 1-1 Seal Water Inlet Welded Attachment RC Pump I-I Seal Water Inlet Welded Attachment RC Pump I-I Seal Water Inlet Welded Attachment RC Pump 1-1 Seal Water Inlet Welded Attachment RC Pump 1-2 Seal Water Inlet Welded Attachment RC Pump 1-2 Seal Water Inlet Welded Attachment RC Pump 1-2 Seal Water Inlet Welded Attachment RC Pump 1-4 Seal Water Inlet Welded Attachment Refuel Water Stor Tank Disch Hdr. Welded Attachment Refuel Water Stor Tank Disch Hdr. Welded Attachment Refuel Water Stor Tank Disch Hdr. Welded Attachment RHR to Refuel Water Storage Tank Welded Attachment RHR to Refuel Water Storage Tank Welded Attachment Line S6-54-2 Line S6-54-2 Line S6-54-2 Line S6-54-2 Line S6-54-2 Line S6-55-2 Line S6-55-2 Line S6-55-2 Line S6-57-2 Line S2-221-18 Line S2-221-18 Line S2-221-18 Line S2-224-8 Line S2-224-8 2151-53 Attach.

X2814A-B 2151-58 Attach.

X2818A-B 2151-147 Attach.

2151-97 Attach.22-212SL Attach.

2155-57 Attach.

2151-54 Attach.

39-9R Attach.

2155-70 Attach.

56S-34V Attach.

57S-29A Attach.

85S-3A Attach.

57S-26V Attach.

57S-27V Attach.

U 1: 2.2-75 U 1: 2.2-75 UI: 2.2-75 UI: 2.2-76 U 1: 2.2-76 UI: 2.2-77 UI: 2.2-78 U 1: 2.2-78 UI: 2.2-82 U 1: 2.2-83 U 1: 2.2-83 UI: 2.2-83 UI: 2.2-84 U 1: 2.2-84 3

3 Examination Also Required if Deformation of Support Member Seen At Any Time Examination Also Required if Deformation of Support Member Seen At Any Time

  • Examination Required if Deformation of Support Member Seen At Any Time
  • Examination Required if Deformation of Support Member Seen At Any Time
  • Examination Required if Deformation of Support Member Seen At Any Time
  • Examination Required if Deformation of Support Member Seen At Any Time
  • Examination Required if Deformation of Support Member Seen At Any Time
  • Examination Required if Deformation of Support Member Seen At Any Time
  • Examination Required if Deformation of Support Member Seen At Any Time
  • Examination Required if Deformation of Support Member Seen At Any Time
  • Examination Required if Deformation of Support Member Seen At Any Time
  • Examination Required if Deformation of Support Member Seen At Any Time
  • Examination Required if Deformation of Support Member Seen At Any Time
  • Examination Required if Deformation of Support Member Seen At Any Time Page 154

ASME Sec. Xl Code Category C-C IS PROGRA PAN ITEM PARTS EXAMINED COMP/LINE WELD/COMP NO.

ISI DWG.

NDE PER. LINE-TOTL RELIEF REQ.

NOTES C3.20 Containment Spray Water Supply Cont'd Welded Attachment Containment Spray Water Supply Welded Attachment Containment Spray Water Supply Welded Attachment Containment Spray Water Supply Welded Attachment Containment Spray Pp 1-1 Suct.

Welded Attachment Containment Spray Pp 1-1 Suct.

Welded Attachment Containment Spray Pp 1-2 Suct.

Welded Attachment Containment Spray Pp 1-2 Disch.

Welded Attachment Containment Spray Pp 1-2 Disch.

Welded Attachment Containment Spray Pp 1-2 Disch.

Welded Attachment Containment Spray Pp 1-1 Disch.

Welded Attachment Containment Spray Pp 1-1 Disch.

Welded Attachment Containment Spray Pp 1-1 Disch.

Welded Attachment Containment Spray Pp I-I Disch.

Welded Attachment Line S2-261-12 Line S2-261-12 Line S2-261-12 Line S2-261-12 Line S2-262-10 Line S2-262-10 Line S2-263-10 Line S2-265-8 Line S2-265-8 Line S2-265-8 Line S2-264-8 Line S2-264-8 Line S2-264-8 Line S2-264-8 99-70V Attach.

57S-195R Attach.

85S-20R Attach.

85S-42A Attach.

97-4R (Location A)

Attach.

97-2A Attach.

97-4R (Location B)

Attach.

97-7R Attach.

98-112R Attach.

58S-28R Attach.97-23A Attach.98-111 R Attach.

58S-23R Attach.

58S-19V Attach.

U 1: 2.2-86 PT U 1: 2.2-86 PT U 1: 2.2-86 PT UI: 2.2-86 PT Ut: 2.2-87 PT Ut: 2.2-87 PT U1: 2.2-88 PT U1: 2.2-89 PT U1: 2.2-89 PT Ut: 2.2-89 PT UI: 2.2-91 PT UI: 2.2-91 PT Ut: 2.2-91 PT U1: 2.2-91 PT

  • Examination Required if Deformation of Support Member Seen At Any Time
  • Examination Required if Deformation of Support Member Seen At Any Time
  • Examination Required if Deformation of Support Member Seen At Any Time
  • Examination Required if Deformation of Support Member Seen At Any Time
  • Examination Required if Deformation of Support Member Seen At Any Time
  • Examination Required if Deformation of Support Member Seen At Any Time
  • Examination Required if Deformation of Support Member Seen At Any Time
  • Examination Required if Deformation of Support Member Seen At Any Time
  • Examination Required if Deformation of Support Member Seen At Any Time
  • Examination Required if Deformation of Support Member Seen At Any Time
  • Examination Required if Deformation of Support Member Seen At Any Time
  • Examination Required if Deformation of Support Member Seen At Any Time
  • Examination Required if Deformation of Support Member Seen At Any Time
  • Examination Required if Deformation of Support Member Seen At Any Time Page 155

ASME Sec. XI 9 oeCategory ISI PRORAM LA ITEM PARTS EXAMINED COMP/LINE WELD/COMP NO.

ISI DWG.

NDE PER. LINE-TOTL RELIEF REQ.

NOTES C3.20 Contain Spray Ring Hdrs 1 & 3 Cont'd Supply Welded Attachment RHR Pps Sup to Spray Hdrs 2 &

4. Welded Attachment Contain Fan Cooler 5 CCW Sup.

Welded Attachment Contain Fan Cooler 5 CCW Sup.

Welded Attachment Contain Fan Cooler 5 CCW Sup.

Welded Attachment Contain Fan Cooler 5 CCW Sup.

Welded Attachment Contain Fan Cooler 4 CCW Sup.

Welded Attachment Contain Fan Cooler 4 CCW Sup.

Welded Attachment Contain Fan Cooler 3 CCW Sup.

Welded Attachment Contain Fan Cooler 3 CCW Sup.

Welded Attachment Contain Fan Cooler 3 CCW Sup.

Welded Attachment Contain Fan Cooler 3 CCW Sup.

Welded Attachment Contain Fan Cooler 3 CCW Sup.

Welded Attachment Contain Fan Cooler 3 CCW Sup.

Welded Attachment Line S3-325-8 Line S2-2520-8 Line K2-314-12 Line K2-314-12 Line K2-314-12 Line K2-314-12 Line K2-315-12 Line K2-315-12 Line K2-316-12 Line K2-316-12 Line K2-316-12 Line K2-316-12 Line K2-316-12 Line K2-316-12 176-128V Attach.

58S-126A Attach.

13-58SL Attach 5-28R Attach 58N-26R Attach 58N-5A Attach 58N-24A Attach 58S-2V Attach 11-115SL Attach 11-1 16R Attach 11-1 17SL Attach 11-29R Attach 13-43R Attach 42-20A Attach U 1: 2.2-92 PT U 1: 2.2-93 PT UI: 2.2-94 446491 U 1: 2.2-94 446491 U 1: 2.2-94 446491 Ul: 2.2-94 446491 U 1: 2.2-95 446503 UI: 2.2-95 446503 U 1: 2.2-96 446503 U 1: 2.2-96 446503 Ul: 2.2-96 446503 UI: 2.2-96 446503 U 1: 2.2-96 446503 U 1: 2.2-96 446503 Page 156 MT MT MT MT MT MT MT MT MT MT MT MT 2

3 2

  • Examination Required if Deformation of Support Member Seen At Any Time
  • Examination Required if Deformation of Support Member Seen At Any Time Examination Also Required if Deformation of Support Member Seen At Any Time Examination Also Required if Deformation of Support Member Seen At Any Time
  • Examination Required if Deformation of Support Member Seen At Any Time Examination Also Required if Deformation of Support Member Seen At Any Time
  • Examination Required if Deformation of Support Member Seen At Any Time Examination Also Required if Deformation of Support Member Seen At Any Time
  • Examination Required if Deformation of Support Member Seen At Any Time
  • Examination Required if Deformation of Support Member Seen At Any Time
  • Examination Required if Deformation of Support Member Seen At Any Time
  • Examination Required if Deformation of Support Member Seen At Any Time
  • Examination Required if Deformation of Support Member Seen At Any Time
  • Examination Required if Deformation of Support Member Seen At Any Time

ASME Sec. XlPe Category C-C II P ROGAMLA NA ITEM PARTS EXAMINED COMP/LINE WELD/COMP NO.

ISI DWG.

NDE PER. LINE-TOTL RELIEF REQ.

NOTES C3.20 Contain Fan Cooler 3 CCW Sup.

Cont'd Welded Attachment Contain Fan Cooler 3 CCW Sup.

Welded Attachment Contain Fan Cooler 2 CCW Sup.

Welded Attachment Contain Fan Cooler 2 CCW Sup.

Welded Attachment Contain Fan Cooler 2 CCW Sup.

Welded Attachment Contain Fan Cooler 2 CCW Sup.

Welded Attachment Contain Fan Cooler 2 CCW Sup.

Welded Attachment Contain Fan Cooler I CCW Sup.

Welded Attachment Contain Fan Cooler I CCW Sup.

Welded Attachment Contain Fan Cooler I CCW Sup.

Welded Attachment Contain Fan Cooler 5 CCW Retn.

Welded Attachment Contain Fan Cooler 5 CCW Retn.

Welded Attachment Contain Fan Cooler 5 CCW Retn.

Welded Attachment Contain Fan Cooler 5 CCW Retn.

Welded Attachment Line K2-316-12 Line K2-316-12 Line K2-317-12 Line K2-317-12 Line K2-317-12 Line K2-317-12 Line K2-317-12 Line K2-318-12 Line K2-318-12 Line K2-318-12 Line K2-319-12 Line K2-319-12 Line K2-319-12 Line K2-319-12 58N-21R Attach 58S-4V Attach I I-1SL Attach 1 -64R Attach 13-16R Attach 42-19A Attach 58S-1 IV Attach 42-12R Attach 42-18A Attach 58S-12V Attach 58N-26R Attach 58N-2R Attach 58N-7A Attach 58S-14V Attach U 1: 2.2-96 446503 Ut: 2.2-96 446503 U 1: 2.2-97 446493 Ut: 2.2-97 446493 U 1: 2.2-97 446493 U 1: 2.2-97 446493 Ut: 2.2-97 446493 Ut: 2.2-98 446493 U 1: 2.2-98 446493 Ut: 2.2-98 446493 U 1: 2.2-99 446491 U 1: 2.2-99 446491 Ut: 2.2-99 446491 U 1: 2.2-99 446491 Page 157 MT MT MT MT MT MT MT MT MT MT MT MT MT MT

  • Examination Required if Deformation of Support Member Seen At Any Time
  • Examination Required if Deformation of Support Member Seen At Any Time
  • Examination Required if Deformation of Support Member Seen At Any Time
  • Examination Required if Deformation of Support Member Seen At Any Time
  • Examination Required if Deformation of Support Member Seen At Any Time
  • Examination Required if Deformation of Support Member Seen At Any Time
  • Examination Required if Deformation of Support Member Seen At Any Time
  • Examination Required if Deformation of Support Member Seen At Any Time
  • Examination Required if Deformation of Support Member Seen At Any Time
  • Examination Required if Deformation of Support Member Seen At Any Time
  • Examination Required if Deformation of Support Member Seen At Any Time
  • Examination Required if Deformation of Support Member Seen At Any Time
  • Examination Required if Deformation of Support Member Seen At Any Time
  • Examination Required if Deformation of Support Member Seen At Any Time

ASME Sec. XI Code Category C-C IS PROGRA PAN ITEM PARTS EXAMINED COMP/LINE WELD/COMP NO.

ISI DWG.

NDE PER. LINE-TOTL RELIEF REQ.

NOTES C3.20 Contain Fan Cooler 4 CCW Retn.

Cont'd Welded Attachment Contain Fan Cooler 4 CCW Retn.

Welded Attachment Contain Fan Cooler 4 CCW Retn.

Welded Attachment Contain Fan Cooler 3 CCW Retn.

Welded Attachment Contain Fan Cooler 3 CCW Retn.

Welded Attachment Contain Fan Cooler 3 CCW Retn.

Welded Attachment Contain Fan Cooler 3 CCW Retn.

Welded Attachment Contain Fan Cooler 3 CCW Retn.

Welded Attachment Contain Fan Cooler 3 CCW Retn.

Welded Attachment Contain Fan Cooler 2 CCW Retn.

Welded Attachment Contain Fan Cooler 2 CCW Retn.

Welded Attachment Contain Fan Cooler 2 CCW Retn.

Welded Attachment Contain Fan Cooler 2 CCW Retn.

Welded Attachment Contain Fan Cooler I CCW Retn.

Welded Attachment Line K2-320-12 Line K2-320-12 Line K2-320-12 Line K2-321-12 Line K2-321-12 Line K2-321-12 Line K2-321-12 Line K2-321-12 Line K2-321-12 Line K2-322-12 Line K2-322-12 Line K2-322-12 Line K2-322-12 Line K2-323-12 13-40SL Attach 58N-23A Attach 58S-5V Attach 11-118SL Attach 11-120SL Attach 13-46R Attach 42-20A Attach 58N-2 1 R Attach 58S-8V Attach 13-18R Attach 288-3 ISL Attach 42-19A Attach 58S-15V Attach 11-34SL Attach Ut: 2.2-100 446503 Ut: 2.2-100 446503 Ut: 2.2-100 446503 U1: 2.2-101 446493 UI: 2.2-101 446493 UI: 2.2-101 446493 UI: 2.2-101 446493 Ut: 2.2-101 446493 UI: 2.2-101 446493 Ut: 2.2-102 446493 Ut: 2.2-102 446493 UI: 2.2-102 446493 Ut: 2.2-102 446493 Ut: 2.2-103 446493 MT MT MT MT MT MT MT MT MT MT MT MT MT MT

  • Examination Required if Deformation of Support Member Seen At Any Time
  • Examination Required if Deformation of Support Member Seen At Any Time
  • Examination Required if Deformation of Support Member Seen At Any Time
  • Examination Required if Deformation of Support Member Seen At Any Time
  • Examination Required if Deformation of Support Member Seen At Any Time
  • Examination Required if Deformation of Support Member Seen At Any Time
  • Examination Required if Deformation of Support Member Seen At Any Time
  • Examination Required if Deformation of Support Member Seen At Any Time
  • Examination Required if Deformation of Support Member Seen At Any Time
  • Examination Required if Deformation of Support Member Seen At Any Time
  • Examination Required if Deformation of Support Member Seen At Any Time
  • Examination Required if Deformation of Support Member Seen At Any Time
  • Examination Required if Deformation of Support Member Seen At Any Time
  • Examination Required if Deformation of Support Member Seen At Any Time I

Page 158

ASME Sec. XI Code Category C-C S

PRGAM PAN Dial Ca n3dI nevlR

.I ITEM PARTS EXAMINED COMP/LINE WELD/COMP NO.

ISI DWG.

NDE PER. LINE-TOTL RELIEF REQ.

NOTES C3.20 Contain Fan Cooler I CCW Retn.

Cont'd Welded Attachment Contain Fan Cooler 1 CCW Retn.

Welded Attachment Stm Gen 1-1 Aux Feedwater Sup.

Welded Attachment Stm Gen 1-1 Aux Feedwater Sup.

Welded Attachment Stm Gen 1-1 Aux Feedwater Sup.

Welded Attachment Stm Gen 1-1 Aux Feedwater Sup.

Welded Attachment Stm Gen I-1 Aux Feedwater Sup.

Welded Attachment Stm Gen 1-1 Aux Feedwater Sup.

Welded Attachment Stm Gen 1-1 Aux Feedwater Sup.

Welded Attachment Aux FW Pp 1-2 Stm Gen 1-1 Disch. Welded Attachment Aux FW Pp 1-2 Stm Gen 1-1 Disch. Welded Attachment Stm Gen 1-2 Aux Feedwater Sup.

Welded Attachment Stm Gen 1-2 Aux Feedwater Sup.

Welded Attachment Stm Gen 1-2 Aux Feedwater Sup.

Welded Attachment Line K2-323-12 Line K2-323-12 Line K16-569-31V Line K16-569-31V Line K 16-569-31V Line K16-569-31V Line.K16-569-31V Line K16-569-31V Line K16-569-31V Line K16-575-31V Line K16-575-31V Line K16-570-3WV Line K16-570-31V Line K16-570-31V 42-18A Attach 58S-16V Attach 11 -26R Attach.

1 1-27SL Attach.

3-9V Attach.

3-5V Attach.

3-36R Attach.

3-46R Attach.

1-20A Attach.

3-1OV Attach 1-20A Attach.

3-1 IV Attach.

1-20A Attach.

3-13V Attach.

Uh: 2.2-103 446493 U1: 2.2-103 446493 UI: 2.2-104 445878 UI: 2.2-104 445878 UI: 2.2-104 445878 Ut: 2.2-104 445878 Uh: 2.2-104 445878 UI: 2.2-104 445878 Uh: 2.2-104 445878 UI: 2.2-104 445878 UI: 2.2-104 445878 UI: 2.2-105 445878 Ul: 2.2-105 445878 Ul: 2.2-105 445878 MT MT MT MT MT MT MT MT MT MT MT MT MT MT

  • Examination Required if Deformation of Support Member Seen At Any Time
  • Examination Required if Deformation of Support Member Seen At Any Time
  • Examination Required if Deformation of Support Member Seen At Any Time
  • Examination Required if Deformation of Support Member Seen At Any Time
  • Examination Required if Deformation of Support Member Seen At Any Time
  • Examination Required if Deformation of Support Member Seen At Any Time
  • Examination Required if Deformation of Support Member Seen At Any Time
  • Examination Required if Deformation of Support Member Seen At Any Time
  • Examination Required if Deformation of Support Member Seen At Any Time
  • Examination Required if Deformation of Support Member Seen At Any Time
  • Examination Required if Deformation of Support Member Seen At Any Time
  • Examination Required if Deformation of Support Member Seen At Any Time
  • Examination Required if Deformation of Support Member Seen At Any Time
  • Examination Required if Deformation of Support Member Seen At Any Time Page 159

ASME Sec. Xl Code Category C-C ISI PRGAMLANA ITEM PARTS EXAMINED COMP/LINE WELD/COMP NO.

ISI DWG.

NDE PER. LINE-TOTL RELIEF REQ.

NOTES C3.20 Aux FW Pp 1-2 Stm Gen 1-2 Cont'd Disch. Welded Attachment Stm Gen 1-3 Aux Feedwater Sup.

Welded Attachment Stm Gen 1-3 Aux Feedwater Sup.

Welded Attachment Stm Gen 1-3 Aux Feedwater Sup.

Welded Attachment Stm Gen 1-3 Aux Feedwater Sup.

Welded Attachment Aux FW Pp 1-3 Stm Gen 1-3 Disch. Welded Attachment Stm Gen 1-4 Aux Feedwater Sup.

Welded Attachment Stm Gen 1-4 Aux Feedwater Sup.

Welded Attachment Stn Gen 1-4 Aux Feedwater Sup.

Welded Attachment Stm Gen 1-4 Aux Feedwater Sup.

Welded Attachment Aux FW Pp 1-3 Stm Gen 1-4 Disch. Welded Attachment Line K16-576-31V Line K16-571-31V Line K16-571-31V Line K16-571-31V Line K16-571-31V Line K16-578-31V Line K16-572-31V Line K16-572-31V Line K16-572-31V Line K16-572-31V Line K16-577-31V 1-20A Attach.

58S-37A Attach.

58S-79R Attach.

58S-80V Attach.15-25R Attach.

58S-37A Attach.

57S-I 17A Attach.

57S-1 18V Attach.

58S-37A Attach.

58S-81V Attach.

58S-37A Attach.

Ut: 2.2-105 445878 UI: 2.2-106 447119 UI: 2.2-106 447119 UI: 2.2-106 447119 UI: 2.2-106 447119 UI: 2.2-106 447119 Ut: 2.2-107 447119 UI: 2.2-107 447119 UI: 2.2-107 447119 UI: 2.2-107 447119 UI: 2.2-107 447119 MT MT MT MT MT MT MT MT MT MT MT

  • Examination Required if Deformation of Support Member Seen At Any Time
  • Examination Required if Deformation of Support Member Seen At Any Time
  • Examination Required if Deformation of Support Member Seen At Any Time
  • Examination Required if Deformation of Support Member Seen At Any Time
  • Examination Required if Deformation of Support Member Seen At Any Time
  • Examination Required if Deformation of Support Member Seen At Any Time
  • Examination Required if Deformation of Support Member Seen At Any Time
  • Examination Required if Deformation of Support Member Seen At Any Time
  • Examination Required if Deformation of Support Member Seen At Any Time
  • Examination Required if Deformation of Support Member Seen At Any Time
  • Examination Required if Deformation of Support Member Seen At Any Time Unit I Attachments Total: 233 Attachments Selected: 24 Percent Examined: 10.3%

(10% Required)

End Unit 1 Piping NOTE: Previously examined attachments are reselected for scheduled examination in conformance with IWC-2420(a).

Page 160

ASME Sec. XI 9 Category C-C S

PRGAM PAN ITEM PARTS EXAMINED COMP/LINE WELD/COMP NO.

ISI DWG.

NDE PER. LINE-TOTL RELIEF REQ.

NOTES C3.20 Piping Unit 2 Welded Attachments:

Loop 4 Hot Leg to RHR Pps.

Welded Attachment Loop 4 Hot Leg to RHR Pps.

Welded Attachment Loop 4 Hot Leg to RHR Pps.

Welded Attachment RHR Heat Exchr 2-1 Outlet.

Welded Attachment Crosstie Chg Pp & SI Pp Suct.

Welded Attachment RHR to SI Pp Suct Void Header.

Welded Attachment RHR Ht Exchrs Outlet X-Tie.

Welded Attachment RHR Inject to Hot Leg

& 2 Welded Attachment RHR Inject to Hot Leg 1& 2 Welded Attachment RHR Inject to Hot Leg I& 2 Welded Attachment PR-IR Inject to Hot Leg I& 2 Welded Attachment RHR Inject to Hot Leg

& 2 Welded Attachment RHR Inject to Hot Leg

& 2 Welded Attachment NOTE: Only lines with welded attachments are listed:

Line 2S 1-927-14111 Line 2S 1-927-14111 Line 2S 1-927-14t11 Line 2S1-3551-14111 Line 2S2-4296-6 Line 2S2-7077-18 Line 2S 1-2458-8111 Line 2S 1-985-12111P Line 2S1-985-12111P Line 2SI-985-121IIP Line 2S1-985-12111P Line 2S1-985-12111P Line 2S1 -985-12111P 48-41 V Attachment 6-1V Attachment 72-77SL Attachment 414-563R Attachment 24-42A Attachment 414-838A Attachment 413-89SL Attachment 412-92SL Attachment 72-25SL Attachment 90-50R Attachment 90-48R Attachment 90-46A Attachment 90-45R Attachment U2: 2.2-1 PT U2: 2.2-1 PT U2: 2.2-1 PT U2:2.2-2 PT U2: 2.2-2 PT U2:2.2-2 PT U2: 2.2-3 PT U2:2.2-4 PT U2:2.2-5 PT U2: 2.2-5 PT U2: 2.2-5 PT U2: 2.2-5 PT U2: 2.2-5 PT 10% of Piping Welded Attachments Req'd Regardless of Attachment Thickness

  • Examination Required if Deformation of Support Member Seen At Any Time
  • Examination Required if Deformation of Support Member Seen At Any Time
  • Examination Required if Deformation of Support Member Seen At Any Time
  • Examination Required if Deformation of Support Member Seen At Any Time
  • Examination Required if Deformation of Support Member Seen At Any Time
  • Examination Required if Deformation of Support Member Seen At Any Time
  • Examination Required if Deformation of Support Member Seen At Any Time
  • Examination Required if Deformation of Support Member Seen At Any Time
  • Examination Required if Deformation of Support Member Seen At Any Time
  • Examination Required if Deformation of Support Member Seen At Any Time
  • Examination Required if Deformation of Support Member Seen At Any Time
  • Examination Required if Deformation of Support Member Seen At Any Time
  • Examination Required if Deformation of Support Member Seen At Any Time Page 161

ASME Sec. X1 Code Category C-C ISI PRGAM PLAN ITEM PARTS EXAMINED COMP/LINE WELD/COMP NO.

1S DWG.

NDE PER. LINE-TOTL RELIEF NOTES REQ.

C3.20 SIS to RCS Loop I Hot Leg Cont'd SIS to RCS Loop I Hot Leg SIS to RCS Loop 2 Hot Leg RHR Pump 2-2 Suction Welded Attachment Cont Sump to RHR Pps Suct.

Welded Attachment Cont Sump to RHR Pps Suct.

Welded Attachment Cont Sump to RHR Pps Suct.

Welded Attachment RHR Pump 2-1 Discharge Welded Attachment RHR Pump 2-1 Discharge Welded Attachment RHR Pump 2-1 Discharge Welded Attachment RHR Ht Exchrs Bypass X-Tie Welded Attachment RHR Ht Exchrs Bypass X-Tie Welded Attachment RHR Pump 2-2 Discharge Welded Attachment RHR Pump 2-2 Discharge Welded Attachment Line 2S6-2575-8 Line 2S6-2575-8 Line 2S6-2576-8 Line 2S 1-111-14111 Line 2S 1-513-14IIP Line 2S1-513-1411P Line 2S 1-513-14111P Line 2S1-112-8111 Line 2S 1-1 12-8111 Line 2S 1 -112-8111 Line 2S1-1663-8111 Line 2S 1 -1663-8111 Line 2S 1-113-8111 Line 2S 1-113-8111 70-55SL Attachment 90-26V Attachment 90-28V Attachment 47-143A Attachment 413-76R Attachment 413 -191R Attachment 46-4A Attachment 77-8SL Attachment 22-9V Attachment 22-6R Attachment 77-7SL Attachment 22-IA Attachment 413-216R Attachment 22-5 V Attachment U2: 2.2-5 U2: 2.2-5 U2: 2.2-5 U2: 2.2-6 U2: 2.2-6 U2: 2.2-6 U2: 2.2-6 U2: 2.2-8 U2: 2.2-8 U2: 2.2-8 U2: 2.2-8 U2: 2.2-9 U2:2.2-9 U2: 2.2-9 PT PT PT PT PT PT PT PT PT PT PT PT PT PT I

  • Examination Required if Deformation of Support Member Seen At Any Time
  • Examination Required if Deformation of Support Member Seen At Any Time
  • Examination Required if Deformation of Support Member Seen At Any Time Examination Also Required if Deformation of Support Member Seen At Any Time
  • Examination Required if Deformation of Support Member Seen At Any Time
  • Examination Required if Deformation of Support Member Seen At Any Time
  • Examination Required if Deformation of Support Member Seen At Any Time
  • Examination Required if Deformation of Support Member Seen At Any Time
  • Examination Required if Deformation of Support Member Seen At Any Time
  • Examination Required if Deformation of Support Member Seen At Any Time
  • Examination Required if Deformation of Support Member Seen At Any Time
  • Examination Required if Deformation of Support Member Seen At Any Time
  • Examination Required if Deformation of Support Member Seen At Any Time

-* Examination Required if Deformation of Support Member Seen At Any Time Page 162

  • 0 ASME Sec. XI Code Category C-C ISI PRGAMLA NA ITEM PARTS EXAMINED COMP/LINE WELD/COMP NO.

ISI DWG.

NDE PER LINE-TOTL RELIEF NOTES REQ.

C3.20 RHR Ht Exchrs Bypass Hdr Cont'd Welded Attachment RHR Ht Exchrs Bypass Hdr Welded Attachment RHR Ht Exchrs Bypass Hdr Welded Attachment RHR Ht Exchrs Bypass Hdr Welded Attachment RHR to SIS Pp 2-2 & Cont Spray.

Welded Attachment RHR to SIS Pp 2-2 & Cont Spray.

Welded Attachment RHR Sup to Spray Hdrs 2 & 4 welded Attachment Safety Inject Pp 2-2 Suction Welded Attachment Safety Inject Pp 2-2 Suction Welded Attachment RHR to Safety Injection Pp Welded Attachment RHR to Safety Injection Pp Welded Attachment Safety Injection Pps Suct Hdr Welded Attachment RHR Ht Exchrs Outlet X-Tie Welded Attachment Cent Charg Pps Disch Hdr Welded Attachment Line 2S 1-1661-8111 Line 2S 1 -1661-8111 Line 2S 1-1661-8111 Line 2S1-1661-8III Line 2S 1-735-811IP Line 2S1-735-8IlIP Line 2S 1-280-811P Line 2S2-1983-6 Line 2S2-1983-6 Line 2S2-1984-6 Line 2S2-1984-6 Line 2S2-1986-8 Line 2S2-1669-8111 Line 2S6-1454-6 48-21R Attachment 24-32R Attachment 22-38R Attachment 24-29A Attachment 47-111 A Attachment 50-128R Attachment 48-26R Attachment 948-5OR Attachment 948-68R Attachment 948-11 R Attachment 48-29A Attachment 948-15A Attachment 413-91SL Attachment 23-36R Attachment U2: 2.2-10 U2: 2.2-10 U2:2.2-10 U2: 2.2-10 U2: 2.2-11 U2: 2.2-11 U2: 2.2-11 U2: 2.2-12 U2: 2.2-12 U2: 2.2-12 U2: 2.2-12 U2: 2.2-13 U2: 2.2-14 U2: 2.2-15

  • Examination Required if Deformation of Support Member Seen At Any Time
  • Examination Required if Deformation of Support Member Seen At Any Time
  • Examination Required if Deformation of Support Member Seen At Any Time
  • Examination Required if Deformation of Support Member Seen At Any Time
  • Examination Required if Deformation of Support Member Seen At Any Time
  • Examination Required if Deformation of Support Member Seen At Any Time
  • Examination Required if Deformation of Support Member Seen At Any Time
  • Examination Required if Deformation of Support Member Seen At Any Time
  • Examination Required if Deformation of Support Member Seen At Any Time
  • Examination Required if Deformation of Support Member Seen At Any Time
  • Examination Required if Deformation of Support Member Seen At Any Time
  • Examination Required if Deformation of Support Member Seen At Any Time
  • Examination Required if Deformation of Support Member Seen At Any Time Examination Also Required if Deformation of Support Member Seen At Any Time Page 163

ASME Sec. XI Code Category C-C S

PRGAM PAN ITEM PARTS EXAMINED COMP/LINE WELD/COMP NO.

ISI DWG.

NDE PER. LINE-TOTL RELIEF REQ.

NOTES C3.20 Cent Charg Pps Disch Hdr Cont'd Welded Attachment Charging Injection Inlet. Welded Attachment Safety Injection Pp 2-1 Suct Welded Attachment Steam Gen Steam Outlet 2-1 Welded Attachment Steam Gcn Steam Outlet 2-1 Welded Attachment Steam Gen Steam Outlet 2-1 Welded Attachment Steam Gen Steam Outlet 2-2 Welded Attachment Steam Gen Steam Outlet 2-2 Welded Attachment Steam Gen Steam Outlet 2-2 Welded Attachment Steam Gen Steam Outlet 2-2 Welded Attachment Steam Gen Steam Outlet 2-3 Welded Attachment Steam Gen Steam Outlet 2-3 Welded Attachment Steam Gen Steam Outlet 2-3 Welded Attachment Main Steam Lead 2-3.Relief lv Hdr. Welded Attachment Line 2S6-1454-6 Line 2S6-2032-6 Line 2S2-1982-6 Line 2K15-228-28V Line 2K15-228-28V Line 2K15-228-28V Line 2K15-227-28V Line 2K15-227-28V Line 2K15-227-28V Line 2K15-227-28V Line 2K15-226-28V Line 2K15-226-28V Line 2K15-226-28V Line 2K15-1065-24V 46-16R Attachment 46-1 tV Attachment 948-67R Attachment 2024-15R Attachment 2020-1V Attachment 413-338R Attachment 2025-15R Attachment 2022-IV Attachment 413-344SL Attachmnt 413-399R Attachment 2026-tV Attachment 413-252R Attachment 2030-15R Attachment 413-305R Attachment U2: 2.2-15 U2: 2.2-15 U2:2.2-16 U2: 2.2-17 U2: 2.2-17 U2: 2.2-17 U2: 2.2-18 U2: 2.2-18 U2: 2.2-18, U2: 2.2-18 U2: 2.2-19 U2: 2.2-19 U2: 2.2-19 U2: 2.2-19 PT PT PT MT MT MT MT MT MT MT MT MT MT, MT

  • Examination Required if Deformation of Support Member Seen At Any Time
  • Examination Required if Deformation of Support Member Seen At Any Time
  • Examination Required if Deformation of Support Member Seen At Any Time Examination Also Required if Deformation of Support Member Seen At Any Time Examination Also Required if Deformation of Support Member Seen At Any Time
  • Examination Required if DefQrmation of Support Member Seen At Any Time Examination Also Required if Deformation of Support Member Seen At Any Time Examination Also Required if Deformation of Support Member Seen At Any Time
  • Examination Required if Deformation of Support Member Seen At Any Time
  • Examination Required if Deformation of Support Member Seen At Any Time Examination Also Required if Deformation of Support Member Seen At Any Time
  • Examination Required if Deformation of Support Member Seen At Any Time Examination Also Required if Deformation of Support Member Seen At Any Time
  • -Examination Required if Deformation of Support Member Seen At Any Time 3

3 Page 164

ASME Sec. XlA Category C-C ISI P ROGAMLAN ITEM PARTS EXAMINED COMP/LINE WELD/COMP NO.

ISI DWG.

NDE PER. LINE-TOTL RELIEF NOTES REQ.

C3.20 Steam Gen Steam Outlet 2-4 Cont'd Welded Attachment Steam Gen Steam Outlet 2-4 Welded Attachment Main Steam Lead 2-4 Relief Vlv Hdr. Welded Attachment Main Steam Lead 2-4 Relief Vlv Hdr. Welded Attachment Main Steam Lead 2-4 Relief Vlv Hdr. Welded Attachment Stm Gen 2-1 Feedwater Sup Welded Attachment Stm Gen 2-1 Feedwater Sup Welded Attachment Stm Gen 2-1 Feedwater Sup Welded Attachment Stm Gen 2-1 Feedwater Sup Welded Attachment Stm Gen 2-2 Feedwater Sup Welded Attachment Stm Gen 2-2 Feedwater Sup Welded Attachment Stm Gen 2-2 Feedwater Sup Welded Attachment Stm Gen 2-3 Feedwater Sup Welded Attachment Stm Gen 2-3 Feedwater Sup Welded Attachment Line 2K 15-225-28V Line 2K1 5-225-28V Line 2K 15-1066-24V Line 2K 15-1066-24V Line 2K 15-1066-24V Line 2K16-554-161V Line 2K16-554-161V Line 2K 16-554-161V Line 2K 16-554-16IV Line 2KI6-555-16IV Line 2KI6-555-16IV Line 2K16-555-16IV Line 2K16-557-16IV Line 2KI6-557-16IV 2028-IV Attachment 413-535R Attachment 413-537SL Attachmnt 413-306R Attachment 2033-16SL & 2029-8V Attachment 2037-7V Attachment 2048-1 5R Attachment 413-267R Attachment 413-278R Attachment 2039-9V Attachment 413-276R Attachment 413-277R Attachment 2042-9V Attachment 2042-IV Attachment U2: 2.2-20 U2: 2.2-20 U2: 2.2-20 U2: 2.2-20 U2: 2.2-20 U2: 2.2-21 U2: 2.2-21 U2: 2.2-21 U2: 2.2-21 U2: 2.2-22 U2: 2.2-22 U2: 2.2-22 U2: 2.2-23 U2: 2.2-23 MT MT MT MT MT MT MT MT MT MT MT MT MT MT 3

3 Examination Also Required if Deformation of Support Member Seen At Any Time

  • Examination Required if Deformation of Support Member Seen At Any Time
  • Examination Required if Deformation of Support Member Seen At Any Time
  • Examination Required if Deformation of Support Member Seen At Any Time
  • Examination Required if Deformation of Support Member Seen At Any Time Examination Also Required if Deformation of Support Member Seen At Any Time
  • Examination Required if Deformation of Support Member Seen At Any Time
  • Examination Required if Deformation of Support Member Seen At Any Time
  • Examination Required if Deformation of Support Member Seen At Any Time Examination Also Required if Deformation of Support Member Seen At Any Time
  • Examination Required if Deformation of Support Member Seen At Any Time
  • Examination Required if Deformation of Support Member Seen At Any Time Examination Also Required if Deformation of Support Member Seen At Any Time
  • Examination Required if Deformation of Support Member Seen At Any Time 3

2 Page 165

  • 0 ASME Sec. XI Code Category C-C ITEM PARTS EXAMINED COMP/LINE WELD/COMP NO.

ISI DWG.

NDE PER. LINE-TOTL RELIEF NOTES REQ.

C3.20 Stm Gen 2-3 Feedwater Sup Cont'd Welded Attachment Stm Gen 2-4 Feedwater Sup Welded Attachment Stm Gen 2-4 Feedwater Sup Welded Attachment Stm Gen 2-4 Feedwater Sup Welded Attachment Stm Gen 2-4 Feedwater Sup Welded Attachment Stm Gen 2-4 Feedwater Sup Welded Attachment RI1R Pump 2-1 Suction Welded Attachment RHR Pump 2-1 Suction Welded Attachment Cont Sump to RHR Pps Suct.

Welded Attachment Cont Sump to RHR Pps Suct.

Welded Attachment RHR Ht Exchr 2-1 Outlet Welded Attachment RHR Ht Exchr 2-1 Outlet Welded Attachment RHR Ht Exchr 2-2 Outlet Welded Attachment RHR Ht Exchr 2-2 Outlet Welded Attachment Line 2K16-557-161V Line 2KI6-556-161V Line 2K 16-556-161V Line 2K16-556-16IV Line 2K16-556-161V Line 2K16-556-161V Line 2S1-1 10-14111 Line 2S1-1 10-14111 Line 2S1-512-14111P Line 2S1-512-14111P Line 2S1-1 18-8111 Line 2S1-1 18-8111 Line 2S1-119-8111 Line 2S1-1 19-8111 2049-1SL Attachment 2044-7V Attachment 2044-IV Attachment 2049-4SL Attachment 2049-5SL Attachment 413-569R Attachment 22-11 R Attachment 47-141A Attachment 22-12R Attachment 46-3A Attachment 414-567R Attachment 414-575A Attachment 413-562R Attachment 414-573A Attachment U2: 2.2-23 U2: 2.2-24 U2:2.2-24 U2: 2.2-24 U2:2.2-24 U2: 2.2-24 U2:2.2-25 U2:2.2-25 U2: 2.2-25 U2:2.2-25 U2: 2.2-26B U2: 2.2-26B U2: 2.2-27A U2: 2.2-27A MT MT MT MT MT MT PT PT PT PT PT PT PT PT 3

  • Examination Required if Deformation of Support Member Seen At Any Time Examination Also Required if Deformation of Support Member Seen At Any Time
  • Examination Required if Deformation of Support Member Seen At Any Time
  • Examination Required if Deformation of Support Member Seen At Any Time
  • Examination Required if Deformation of Support Member Seen At Any Time
  • Examination Required if Deformation of Support Member Seen At Any Time
  • Examination Required if Deformation of Support Member Seen At Any Time
  • Examination Required if Deformation of Support Member Seen At Any Time
  • Examination Required if Deformation of Support Member Seen At Any Time
  • Examination Required if Deformation of Support Member Seen At Any Time
  • Examination Required if Deformation of Support Member Seen At Any Time
  • Examination Required if Deformation of Support Member Seen At Any Time
  • Examination Required if Deformation of Support Member Seen At Any Time
  • Examination Required if Deformation of Support Member Seen At Any Time Page 166

ASME Sec. Xl Code Category C-C ISI PRGAM PLAN ITEM PARTS EXAMINED COMP/LINE WELD/COMP NO.

11 DWG.

NDE PER. LINE-TOTL RELIEF NOTES REQ.

C3.20 Charg Pps Suct From RWST Cont'd Welded Attachment RHR Sup to Spray Hdrs I & 3 Welded Attachment RHR Sup to Spray Hdrs 1 & 3 Welded Attachment PdRHR Pp 2-1 Inj Cold Leg 1&2 Welded Attachment RHR Pp 2-1 lnj Cold Leg l&2 Welded Attachment RHR Pp 2-1 lnj Cold Leg l&2 Welded Attachment RHR Pp 2-1 Inj Cold Leg l&2 Welded Attachment RHR Pp 2-2 lnj Cold Leg 3 & 4 Welded Attachment RHR Pp 2-2 lnj Cold Leg 3 & 4 Welded Attachment RHR Pp 2-2 Inj Cold Leg 3 & 4 Welded Attachment RHR Pp 2-2 Inject Cold Leg 4 Welded Attachment RHR Pp 2-1 Inject Cold Leg 1 Welded Attachment RHR Pp 2-1 Inject Cold Leg 2 Welded Attachment Cent Charging Pp 2-1 Suction Welded Attachment Line 2S2-1987-8 Line 2S 1-279-811IP Line 2S 1-279-8111P Line 2S 1-508-8111 Line 2S 1-508-81I1 Line 2S 1 -508-8111 Line 2S 1-508-8111 Line 2S1-509-8111 Line 2S 1-509-8111 Line 2S 1-509-8111 Line 2S6-3847-6SPL Line 2S6-3844-6SPL Line 2S6-3845-6SPL Line 2S2-42-6 24-6A Attachment 47-108A Attachment 49-70V Attachment 8-52A Attachment 8-49R Attachment 71-16SL Attachment 71-46SL Attachment 8-55A Attachment 7-5R Attachment 8-54V Attachment 8-58V Attachment 92-37A Attachment 92-60R Attachment 23-20R Attachment U2: 2.2-28 U2: 2.2-29 U2: 2.2-29 U2: 2.2-31 U2: 2.2-31 U2: 2.2-32 U2: 2.2-32 U2: 2.2-33 U2: 2.2-33 U2: 2.2-33 U2: 2.2-33 U2: 2.2-34 U2: 2.2-34 U2: 2.2-35 PT PT PT PT PT PT PT PT PT PT PT PT PT PT 2

  • Examination Required if Deformation of Support Member Seen At Any Time
  • Examination Required if Deformation of Support Member Seen At Any Time
  • Examination Required if Deformation of Support Member Seen At Any Time
  • Examination Required if Deformation of Support Member Seen At Any Time Examination Also Required if Deformation of Support Member Seen At Any Time
  • Examination Required if Deformation of Support Member Seen At Any Time
  • Examination Required if Deformation of Support Member Seen At Any Time Examination Also Required if Deformation of Support Member Seen At Any Time
  • Examination Required if Deformation of Support Member Seen At Any Time
  • Examination Required if Deformation of Support Member Seen At Any Time
  • Examination Required if Deformation of Support Member Seen At Any Time
  • Examination Required if Deformation of Support Member Seen At Any Time
  • Examination Required if Deformation of Support Member Seen At Any Time
  • Examination Required if Deformation of Support Member Seen At Any Time I

Page 167

ASME Sec. Xl ode Category C-C 0

ISI PRGAM.

PAN ITEM PARTS EXAMINED COMP/LINE WELD/COMP NO.

ISI DWG.

NDE PER. LINE-TOTL RELIEF REQ.

NOTES C3.20 Cent Charging Pp 2-1 Suction Cont'd Welded Attachment Cent Charg Pp 2-1 Discharge Welded Attachment Chg Pp 2-1 BP Supply to Seal Inj.

Welded Attachment Chg Pp 2-1 BP Supply to Seal Inj.

Welded Attachment Cent Charging Pps Disch Hdr Welded Attachment Cent Charging Pps Disch Hdr Welded Attachment Charg Pp 2-2 BP Sup to Seal Inj.

Welded Attachment Recip Charging Pp 2-3 Disch Welded Attachment Recip Charging Pp 2-3 Disch Welded Attachment Regn Hx In Chg Ln to 2V-8106 Welded Attachment Regn Hx In Chg Ln to 2V-8106 Welded Attachment Regn Hx In Chg Ln to 2V-8106 Welded Attachment Rcgn Hx In Chg Ln to 2V-8106 Welded Attachment Regn Hx In Chg Ln to 2V-8106 Welded Attachment Line 2S2-42-6 Line 2S2-45-4 Line 2S6-1474-3 Line 2S6-1474-3 Line 2S6-3678-3 Line 2S6-3678-3 Line 2S6-1475-3 Line 2S6-47-3 Line 2S6-47-3 Line 2S6-48-3 Line 2S6-48-3 Line 2S6-48-3 Line 2S6-48-3 Line 2S6-48-3 414-401 R Attachment 23-35R Attachment Lugs23-34R Attachment Lugs23-40R Attachment 46-17R Attachment 23-47A Attachment 23-37R Attachment Lugs23-50R Attachment Lugs23-48A Attachment 949-190V Attachment 47-91A Attachment 949-19 IV Attachment 47-96A Attachment 949-194A Attachment U2: 2.2-35 U2: 2.2-38 U2: 2.2-39 U2: 2.2-39 U2:2.2-40 U2: 2.2-40 U2: 2.2-42 U2: 2.2-43 U2:2.2-43 U2: 2.2-44 U2: 2.2-44 U2: 2.2-44 U2: 2.2-44 U2: 2.2-44 PT PT PT PT PT PT PT PT PT PT PT PT PT PT

  • Examination Required if Deformation of Support Member Seen At Any Time Examination Also Required if Deformation of Support Member Seen At Any Time Examination Also Required if Deformation of Support Member Seen At Any Time
  • Examination Required if Deformation of Support Member Seen At Any Time
  • Examination Required if Deformation of Support Member Seen At Any Time
  • Examination Required if Deformation of Support Member Seen At Any Time Examination Also Required if Deformation of Support Member Seen At Any Time Examination Also Required if Deformation of Support Member Seen At Any Time
  • Examination Required if Deformation of Support Member Seen At Any Time
  • Examination Required if Deformation of Support Member Seen At Any Time
  • Examination Required if Deformation of Support Member Seen At Any Time
  • Examination Also Required if Deformation of Support Member Seen At Any Time
  • Examination Required if Deformation of Support Member Seen At Any Time
  • Examination Required if Deformation of Support Member Seen At Any Time I

Page 168

ASME Sec. X1 9 Category C-C S

PRGAM PAN Dial Cayn r

ntra Rv ITEM PARTS EXAMINED COMP/LINE WELD/COMP NO.

11 DWG.

NDE PER% LINE-TOTL RELIEF NOTES REQ.

C3.20 Regn Hx In Chg Ln to 2V-8106 Cont'd Welded Attachment Charging Pps Disch Emerg 2 Welded Attachment Charging Injection Out Welded Attachment Charging Injection Out Hdr Welded Attachment Charging Pps Discharge Hdr Welded Attachment Charging Pumps Seal Supply Welded Attachment Charging Pumps Seal Supply Welded Attachment CVCS Seal Inj Filter 2-2 Inlet Welded Attachment CVCS Seal lnj Filter 2-2 Outlet Welded Attachment CVCS Seal Inj Filter 2-4 Inlet Welded Attachment CVCS Seal Inj Filter 2-1 Outlet Welded Attachment React Coolant Pps Seal Wtr Inlet.

Welded Attachment Charg Pp 2-1 Bypass Miniflow Welded Attachment Charg Pp 2-2 Bypass Miniflow Welded Attachment Line 2S6-48-3 Line 2S6-1975-4 Line 2S6-2033-4 Line 2S6-1016-3 Line 2S6-52-3 Line 2S6-53-3 Line 2S6-53-3 Line 2S6-2047-3 Line 2S6-2048 Line 2S6-2044-3 Line 2S6-2046-3 Line 2S6-746-3 Line 2S6-1466-2 Line 2S6-1468-2 24-27A Attachment 46-13R Attachment 414-558A Attachment 413-84V Attachment 949-193A Attachment 23-45A Attachment 24-30A Attachment 413-94A Attachment 413-96A Attachment 413-95A Attachment

'413-97A Attachment 49-112A Attachment 923-48 Attachment 923-54 Attachment U2:2.2-44 PT U2: 2.2-47 PT U2: 2.2-48 PT U2: 2.2-53 PT U2: 2.2-54 PT U2: 2.2-55 PT U2: 2.2-55 PT U2: 2.2-56 PT U2: 2.2-58 PT U2: 2.2-59.

PT U2: 2.2-60 PT U2:2.2-61 PT

  • Examination Required if Deformation of Support Member Seen At Any Time
  • Examination Required if Deformation of Support Member Seen At Any Time
  • Examination Required if Deformation of Support Member Seen At Any Time
  • Examination Required if Deformation of Support Member Seen At Any Time
  • Examination Required if Deformation of Support Member Seen At Any Time
  • Examination Required if Deformation of Support Member Seen At Any Time
  • Examination Required if Deformation of Support Member Seen At Any Time
  • Examination Required if Deformation of Support Member Seen At Any Time
  • Examination Required if Deformation of Support Member Seen At Any Time
  • Examination Required if Deformation of Support Member Seen At Any Time
  • Examination Required if Deformation of Support Member Seen At Any Time
  • Examination Required if Deformation of Support Member Seen At Any Time
  • Examination Required if Deformation of Support Member Seen At Any Time
  • Examination Required if Deformation of Support Member Seen At Any Time U2: 2.2-63 PT U2: 2.2-64 PT Page 169

ASME Sec. Xl Code Category C-C ISI PRGAMLANA ITEM PARTS EXAMINED COMP/LINE WELD/COMP NO.

ISI DWG.

NDE PER. LINE-TOTL RELIEF NOTES REQ.

C3.20 Cent Chg Pp Byp Miniflow Hdr.

Cont'd Welded Attachment React Coolant Pp 2-1 Seal Wtr In.

Welded Attachment React Coolant Pp 2-1 Seal Wtr In.

Welded Attachment React Coolant Pp 2-1 Seal Wtr In.

Welded Attachment React Coolant Pp 2-1 Seal Wtr In.

Welded Attachment React Coolant Pp 2-1 Seal Wtr In.

Welded Attachment React Coolant Pp 2-2 Seal Wtr In.

Welded Attachment React Coolant Pp 2-2 Seal Wtr In.

Welded Attachment React Coolant Pp 2-2 Seal Wtr In.

Welded Attachment React Coolant Pp 2-2 Seal Wtr In.

Welded Attachment React Coolant Pp 2-4 Seal Wtr In.

Welded Attachment RWST Disch. Hdr. Welded Attachment RWST Disch. Hdr. Welded Attachment Line 2S6-1464-2 Line 2S6-54-2 Line 2S6-54-2 Line 2S6-54-2 Line 2S6-54-2 Line 2S6-54-2 Line 2S6-55-2 Line 2S6-55-2 Line 2S6-55-2 Line 2S6-55-2 Line 2S6-57-2 Line 2S2-221-18 Line 2S2-221-18 Line 2S2-221-18 923-55 Attachment 2216-1 Attachment 564-19 Attachment 78-505SL Attachment 564-35 Attachment 564-33 Attachment 2730-103 Attachment 564-11 Attachment 564-15 Attachment 78-99SL Attachment 2216-54 Attachment 35N-3A Attachment 49-29A Attachment 413-154SL Attachment U2: 2.2-65 U2: 2.2-70 U2: 2.2-74 U2: 2.2-74 U2: 2.2-75 U2: 2.2-75 U2: 2.2-71 U2: 2.2-77 U2: 2.2-77 U2: 2.2-78 U2: 2.2-73 U2: 2.2-83 516924 U2: 2.2-83 516924 PT PT PT PT PT PT PT PT PT PT PT PT PT

  • Examination Required if Deformation of Support Member Seen At Any Time
  • Examination Required if Deformation of Support Member Seen At Any Time
  • Examination Required if Deformation of Support Member Seen At Any Time
  • Examination Required if Deformation of Support Member Seen At Any Time
  • Examination Required if Deformation of Support Member Seen At Any Time
  • Examination Required if Deformation of Support Member Seen At Any Time
  • Examination Required if Deformation of Support Member Seen At Any Time
  • Examination Required if Deformation of Support Member Seen At Any Time
  • Examination Required if Deformation of Support Member Seen At Any Time
  • Examination Required if Deformation of Support Member Seen At Any Time
  • Examination Required if Deformation of Support Member Seen At Any Time
  • Examination Required if Deformation of Support Member Seen At Any Time
  • Examination Required if Deformation of Support Member Seen At Any Time
  • Examination Required if Deformation of Support Member Seen At Any Time RWST Disch. Hdr. Welded Attachment U2: 2.2-83 PT 516924 Page 170

ASME Sec. XI Code Category C-C Diablo Canon31d Ine-al Rv ITEM PARTS EXAMINED COMP/LINE WELD/COMP NO.

ISI DWG.

NDE PER. LINE-TOTL RELIEF REQ.

NOTES C3.20 RWST Disch. Hdr. Welded Cont'd Attachment Containment Spray Wtr Supply Welded Attachment Containment Spray Wtr Supply Welded Attachment Containment Spray Wtr Supply Welded Attachment Containment Spray Wtr Supply Welded Attachment Containment Spray Wtr Supply Welded Attachment Containment Spray Pp 2-1 Suet Welded Attachment Containment Spray Pp 2-2 Suet Welded Attachment Containment Spray Pp 2-1 Disch Welded Attachment Containment Spray Pp 2-1 Disch Welded Attachment Containment Spray Pp 2-1 Disch Welded Attachment Containment Spray Pp 2-2 Disch Welded Attachment Containment Spray Pp 2-2 Disch Welded Attachment Containment Spray Pp 2-2 Disch Welded Attachment Line 2S2-221-18 Line S2-261-12 Line S2-261-12 Line S2-261-12 Line S2-261-12 Line S2-261-12 Line S2-262-10 Line S2-263-10 Line S2-264-8 Line S2-264-8 Line S2-264-8 Line S2-265-8 Line S2-265-8 Line S2-265-8 48-34V Attachment 35N-42A Attachment 35N-20R Attachment 49-195R Attachment 949-17V Attachment 947-2A Attachment 413-526V Attachment 413-527V Attachment 50-23R Attachment 50-19V Attachment 50-33A Attachment 947-17A Attachment 50-28R Attachment 50-26V Attachment U2: 2.2-83 516924 U2: 2.2-85 449299 U2: 2.2-85 449299 U2: 2.2-85 449299 U2: 2.2-85 449299 U2: 2.2-85 449299 U2: 2.2-86 PT PT 2

PT PT PT PT PT

  • Examination Required if Deformation of Support Member Seen At Any Time
  • Examination Also Required if Deformation of Support Member Seen At Any Time
  • Examination Required if Deformation of Support Member Seen At Any Time
  • Examination Required if Deformation of Support Member Seen At Any Time
  • Examination Required if Deformation of Support Member Seen At Any Time
  • Examination Required if Deformation of Support Member Seen At Any Time
  • Examination Required if Deformation of Support Member Seen At Any Time
  • Examination Required if Deformation of Support Member Seen At Any Time
  • Examination Required if Deformation of Support Member Seen At Any Time
  • Examination Required if Deformation of Support Member Seen At Any Time
  • Examination Required if Deformation of Support Member Seen At Any Time
  • Examination Required if Deformation of Support Member Seen At Any Time
  • Examination Required if Deformation of Support Member Seen At Any Time
  • Examination Required if Deformation of Support Member Seen At Any Time U2: 2.2-87 PT U2: 2.2-90 PT U2: 2.2-90 PT U2: 2.2-90 PT U2: 2.2-88 PT U2: 2.2-88 PT U2: 2.2-88 PT Page 171
  • 0 ASME Sec. Xl Code Category C-C II PRGAM PLAN Diabo..on3dItrvlRv ITEM PARTS EXAMINED COMP/LINE WELD/COMP NO.

ISI DWG.

NDE PER. LINE-TOTL RELIEF REQ.

NOTES C3.20 Spray Ring Hdrs 1 & 3 Supply Cont'd Welded Attachment Spray Ring Hdrs 2 & 4 Supply Welded Attachment RHR Pps Wtr Spray Hdrs I & 3 Welded Attachment Contain Fan Cooler 5 CCW Sup.

Welded Attachment Contain Fan Cooler 5 CCW Sup.

Welded Attachment Contain Fan Cooler 5 CCW Sup.

Welded Attachment Contain Fan Cooler 5 CCW Sup.

Welded Attachment Contain Fan Cooler 4 CCW Sup.

Welded Attachment Contain Fan Cooler 4 CCW Sup.

Welded Attachment Contain Fan Cooler 4 CCW Sup.

Welded Attachment Contain Fan Cooler 3 CCW Sup.

Welded Attachment Contain Fan Cooler 3 CCW Sup.

Welded Attachment Contain Fan Cooler 3 CCW Sup.

Welded Attachment Contain Fan Cooler 3 CCW Sup.

Welded Attachment Line S2-325-8 Line S2-326-8 Line S2-2520-8 Line 2K2-314-12 Line 2K2-314-12 Line 2K2-314-12 Line 2K2-314-12 Line 2K2-315-12 Line 2K2-315-12 Line 2K2-315-12 Line 2K2-316-12 Line 2K2-316-12 Line 2K2-316712 Line 2K2-316-12 20-128V Attachment 20-136V Attachment 50-126A Attachment 8-25V Attachment 4 14-347SL Attachment 8-5A Attachment 8-26R Attachment 50-2V Attachment 414-15SL Attachment 8-24A Attachment 414-22SL Attachment 414-239SL Attachment 71-32R Attachment 414-262SL Attachment U2: 2.2-92 PT U2:-2.2-89 PT U2: 2.2-93 PT U2: 2.2-94 MT U2: 2.2-94 MT U2: 2.2-94 MT U2: 2.2-94 MT U2: 2.2-95 MT U2: 2.2-95 MT U2: 2.2-95 MT U2: 2.2-96 MT

  • Examination Required if Deformation of Support Member Seen At Any Time
  • Examination Required if Deformation of Support Member Seen At Any Time
  • Examination Required if Deformation of Support Member Seen At Any Time
  • Examination Required if Deformation of Support Member Seen At Any Time
  • Examination Required if Deformation of Support Member Seen At Any Time
  • Examination Required if Deformation of Support Member Seen At Any Time
  • Examination Required if Deformation of Support Member Seen At Any Time
  • Examination Required if Deformation of Support Member Seen At Any Time
  • Examination Required if Deformation of Support Member Seen At Any Time
  • Exanmination Required if Deformation of Support Member Seen At Any Time
  • Examination Required if Deformation of Support Member Seen At Any Time
  • Examination-Required if Deformation of Support Member Seen At Any Time
  • Examination Required if Deformation of Support Member Seen At Any Time
  • Examination Required if Deformation of Support Member Seen At Any Time U2: 2.2-96 U2: 2.2-96 MT MT U2: 2.2-96 MT Page 172

ASME Sec. Xl 9 Category C-C IS POGRAMA PAN DiaboCnon3dItrvlRv ITEM PARTS EXAMINED COMP/LINE WELD/COMP NO.

ISI DWG.

NDE PER. LINE-TOTL RELIEF REQ.

NOTES C3.20 Contain Fan Cooler 3 CCW Sup.

Cont'd Welded Attachment Contain Fan Cooler 3 CCW Sup.

Welded Attachment Contain Fan Cooler 2 CCW Sup.

Welded Attachment Contain Fan Cooler 2 CCW Sup.

Welded Attachment Contain Fan Cooler 2 CCW Sup.

Welded Attachment Contain Fan Cooler 2 CCW Sup.

Welded Attachment Contain Fan Cooler 2 CCW Sup.

Welded Attachment Contain Fan Cooler 2 CCW Sup.

Welded Attachment Contain Fan Cooler 1 CCW Sup.

Welded Attachment Contain Fan Cooler 1 CCW Sup.

Welded Attachment.

Contain Fan Cooler I CCW Sup.

Welded Attachment Contain Fan Cooler 1 CCW Sup.

Welded Attachment Contain Fan Cooler I CCW Sup.

Welded Attachment Contain Fan Cooler 1 CCW Sup.

Welded Attachment Line 2K2-316-12 Line 2K2-316-12 Line 2K2-317-12 Line 2K2-317-12 Line 2K2-317-12 Line 2K2-317-12 Line 2K2-317-12 Line 2K2-317-12 Line 2K2-318-12 Line 2K2-318-12 Line 2K2-318-12 Line 2K2-318-12 Line 2K2-318-12 Line 2K2-318-12 414-24SL Attachment 414-377A Attachment 414-52R Attachment 71-30SL Attachment 414-273SL Attachment 414-71R Attachment 73-15R Attachment 92-19A Attachment 50-12V Attachment 73-14SL Attachment 414-307R Attachment 414-198SL Attachment 414-376A Attachment 414-347R Attachment U2: 2.2-96 MT U2: 2.2-96 MT U2: 2.2-97 MT U2: 2.2-97 MT

-U2: 2.2-97 MT U2: 2.2-97 MT U2: 2.2-97 MT U2: 2.2-97 MT U2: 2.2-98 MT U2: 2.2-98 MT

  • Examination Required if Deformation of Support Member Seen At Any Time
  • Examination Required if Deformation of Support Member Seen At Any Time
  • Examination Required if Deformation of Support Member Seen At Any Time
  • Examination Required if Deformation of Support Member Seen At Any Time
  • Examination Required if Deformation of Support Member Seen At Any Time
  • Examination Required if Deformation of Support Member Seen At Any Time
  • Examination Required if Deformation of Support Member Seen At Any Time
  • Examination Required if Deformation of Support Member Seen At Any Time
  • Examination Required if Deformation of Support Member Seen At Any Time
  • Examination Required if Deformation of Support Member Seen At Any Time
  • Examination Required if Deformation of Support Member Seen At Any Time
  • Examination Required if Deformation of Support Member Seen At-Any Time
  • Examination Required if Deformation of Support Member Seen At Any Time
  • Examination Required if Deformation of Support Member Seen At Any Time U2: 2.2-98 MT U2: 2.2-98 MT U2:2.2-98 MT U2: 2.2-98 MT Page 173

ASME Sec. X1 Code Category C-C IS POGA PALANA ITEM PARTS EXAMINED COMP/LINE WELD/COMP NO.

ISI DWG.

NDE PER. LINE-TOTL RELIEF REQ.

NOTES C3.20 Contain Fan Cooler I CCW Sup.

Cont'd Welded Attachment Contain Fan Cooler I CCW Sup.

Welded Attachment Contain Fan Cooler I CCW Sup.

Welded Attachment Contain Fan Cooler I CCW Sup.

Welded Attachment Contain Fan Cooler 1 CCW Sup.

Welded Attachment Contain Fan Cooler 5 CCW Retn.

Welded Attachment Contain Fan Cooler 5 CCW Retn.

Welded Attachment Contain Fan Cooler 5 CCW Retn.

Welded Attachment Contain Fan Cooler 5 CCW Retn.

Welded Attachment Contain Fan Cooler 4 CCW Rem.

Welded Attachment Contain Fan Cooler 4 CCW Rem.

Welded Attachment Contain Fan Cooler 4 CCW Retn.

Welded Attachment Contain Fan Cooler 3 CCW Rem.

Welded Attachment Contain Fan Cooler 3 CCW Retn.

Welded Attachment Line 2K2-318-12 Line 2K2-318-12 Line 2K2-318-12 Line 2K2-318-12 Line 2K2-318-12 Line 2K2-319-12 Line 2K2-319-12 Line 2K2-319-12 Line 2K2-319-12 Line 21(2-320-12 Line 2K2-320-12 Line 2K2-320-12 Line 2K2-321-12 Line 2K2-321-12 414-205R Attachment 414-200SL Attachment 71-42SL Attachment 71-35SL Attachment 71-36SL Attachment 8-7A Attachment 8-2R Attachment 414-14R Attachment 8-26R Attachment 50-5V Attachment 414-237SL Attachment 8-23A Attachment 414-20SL Attachment 414-258SL Attachment U2: 2.2-98 MT U2: 2.2-98 MT U2: 2.2-98 MT U2: 2.2-98 MT U2: 2.2-98 MT U2: 2.2-99 MT U2: 2.2-99 MT U2: 2.2-99 MT U2: 2.2-99 MT U2: 2.2-100 MT U2: 2.2-100 MT U2: 2.2-100 MT U2: 2.2-101 MT U2: 2.2-101 MT

  • Examination Required if Deformation of Support Member Seen At Any Time
  • Examination Required if Deformation of Support Member Seen At Any Time
  • Examination Required if Deformation of Support Member Seen At Any Time
  • Examination Required if Deformation of Support Member Seen At Any Time
  • Examination Required if Deformation of Support Member Seen At Any Time
  • Examination Required if Deformation of Support Member Seen At Any Time
  • Examination Required if Deformation of Support Member Seen At Any Time
  • Examination Required if Deformation of Support Member Seen At Any Time
  • Examination Required if Deformation of Support Member Seen At Any Time
  • Examination Required if Deformation of Support Member Seen At Any Time
  • Examination Required if Deformation of Support Member Seen At Any Time
  • Examination Required if Deformation of Support Member Seen At Any Time
  • Examination Required if Deformation of Support Member Seen At Any Time
  • Examination Required if Deformation of Support Member Seen At Any Time Page 174

S o

ASME Sec. XI Code Category C-C II PRGAMA PAN ITEM PARTS EXAMINED COMP/LINE WELD/COMP NO.

ISI DWG.

NDE PER. LINE-TOTL RELIEF REQ.

NOTES C3,20 Contain Fan Cooler 3 CCW Retn.

Cont'd Welded Attachment Contain Fan Cooler 3 CCW Remn.

Welded Attachment Contain Fan Cooler 2 CCW Retn.

Welded Attachment Contain Fan Cooler 2 CCW Retn.

Welded Attachment Contain Fan Cooler 2 CCW Retn.

Welded Attachment Contain Fan Cooler 2 CCW Remn.

Welded Attachment Contain Fan Cooler 1 CCW Retn.

Welded Attachment Contain Fan Cooler 1 CCW Retn.

Welded Attachment Contain Fan Cooler 1 CCW Retn.

Welded Attachment Contain Fan Cooler I CCW Rein.

Welded Attachment Contain Fan Cooler I CCW Retn.

Welded Attachment Stm Gen 2-2 Aux Feedwater Sup.

Welded Attachment Stm Gen 2-3 Aux Feedwater Sup.

Welded Attachment Stm Gen 2-3 Aux Feedwater Sup.

Welded Attachment Line 2K2-321-12 Line 2K2-321-12 Line 2K2-322-12 Line 2K2-322-12 Line 2K2-322-12 Line 2K2-322-12 Line 2K2-323-12 Line 2K2-323-12 Line 2K2-323-12 Line 2K2-323-12 Line 2K2-323-12 Line 2KI6-570-31V Line 2K16-571-31V Line 2K16-571-31V 92-20A Attachment 414-18SL Attachment 71-29SL Attachment 71-31 SL Attachment 73-16R Attachment 414-399A Attachment 50-16V Attachment 414-306R Attachment 71-33SL Attachment 71-37SL Attachment 71-38SL Attachment 111-31R Attach. Lugs 413-296V Attach. Stan 414-16A Attach. Stan.

U2: 2.2-101 MT U2: 2.2-101 MT U2: 2.2-102 MT U2: 2.2-102 MT U2: 2.2-102 MT U2: 2.2-102 MT U2: 2.2-103 MT U2: 2.2-103 MT U2: 2.2-103 MT U2:2.2-103 MT U2:2.2-103 MT

  • Examination Required if Deformation of Support Member Seen At Any Time
  • Examination Required if Deformation of Support Member Seen At Any Time
  • Examination Required if Deformation of Support Member Seen At Any Time
  • Examination Required if Deformation of Support Member Seen At Any Time
  • Examination Required if Deformation of Support Member Seen At Any Time
  • Examination Required if Deformation of Support Member Seen At Any Time
  • Examination Required if Deformation of Support Member Seen At Any Time
  • Examination Required if Deformation of Support Member Seen At Any Time
  • Examination Required if Deformation of Support Member Seen At Any Time
  • Examination Required if Deformation of Support Member Seen At Any Time
  • Examination Required if Deformation of Support Member Seen At Any Time
  • Examination Required if Deformation of Support Member Seen At Any Time
  • Examination Required if Deformation of Support Member Seen At Any Time
  • Examination Required if Deformation of Support Member Seen At Any Time U2: 2.2-83 516924 U2: 2.2-84 449299 U2: 2.2-84 449299 Page 175 MT MT MT

ASME Sec. XI Code Category C-C II PROGAM PAN Dial avn3dItra Re.I ITEM PARTS EXAMINED COMP/LINE

,WELD/COMP NO.

ISI DWG.

NDE PER. LINE-TOTL RELIEF REQ.

NOTES C3.20 Cont'd Aux FW Pp 2-3 Stm Gen 2-3 Disch. Welded Attachment Stm Gen 2-4 Aux Feedwater Sup.

Welded Attachment Stm Gen 2-4 Aux Feedwater Sup.

Welded Attachment Stm Gen 2-4 Aux Feedwater Sup.

Welded Attachment Aux FW Pp 2-3 Stm Gen 2-4 Disch. Welded Attachment Unit 2 Attachments Total: 214 Line 2K16-578-3IV Line 2K16-572-31V Line 2K16-572-31V Line 2K16-572-31V Line 2K16-577-31V 414-19A Attach. Stan.

414-17A Attach. Stan.

49-117A Attach. Stan.50-35R Attach. Tabs50-37A Attach. Stan.

U2: 2.2-84 449299 U2: 2.2-85 449299 U2: 2.2-85 449299 U2: 2.2-85 449299 U2: 2.2-85 449299 MT MT MT MT

  • Examination Required if Deformation of Support Member Seen At Any Time
  • Examination Required if Deformation of Support Member Seen At Any Time
  • Examination Required if Deformation of Support Member Seen At Any Time
  • Examination Required if Deformation of Support Member Seen AtAny Time
  • Examination Also Required if Deformation of Support Member Seen At Any Time MT-3 Attachments Selected: 22 Percent Examined: 10.2%

(10% Required)

End Unit 2 Piping NOTE: Previously examined attachments are reselected for scheduled examination in conformance with 1WC-2420(a).

Page 176

ASME Sec. Xl Code Category C-C S

PRGAM PAN DiaboCno r

nevlRv ITEM PARTS EXAMINED COMP/LINE WELD/COMP NO.

ISI DWG.

NDE PER. LINE-TOTL RELIEF REQ.

NOTES C3.30 Pumps Integrally Welded Attachments None, or Not Required (IWC-2500-1 Footnote 1) for the following:

RHR Pumps, Safety Injection Pumps, Reciprocating Charging Pump, Unit 1 or Unit 2 C3.30 Centrifugal Charging Pump 1-1:

Cent Chg Pp 1-I Welded Attachments Attachment Weld Items 1,2 UI: 2.3-3 PT/MT I

Examination Also Required if Deformation of Support Member Seen At Any Time CCP's have 4 attachments each; 10% required Examination Also Required if Deformation of Support Member Seen At Any Time C3.30 Centrifugal Charging Pump 2-1:

CentChg Pp 2-1 Welded Attachments Attachment Weld Items 3,4 U2: 2.3-3 PT C3.40 None, Unit I or Unit 2 (No attachment welds to valves)

None None Page 177

ASME Sec. XI Code Category C-D PS PRGAM PLAN ITEM PARTS EXAMINED COMP/LINE WELD/COMP NO.

ISI DWG.

NDE PER.

LINE-RELIEF TOTL-%

REQ.

BLOCK NOTES C4.10 Pressure Vessels Bolts and Studs

(>2" diameter)

C4.20 Piping Bolts and Studs (>2" diameter)

None (Unit I or Unit 2)

None (Unit I or Unit 2)

None None C4.30 Pumps Bolts and Studs (>2" diameter)

None for the Pumps Noted:

None for the Pumps Noted:

N/A for RHR Pumps, Charging Pumps (Unit I oreUnit 2)

RHR Pumps, Charging Pumps, Unit I or Unit 2 C4.30 Safety Injection Pump 1-1:

Bolting >2" diameter C4.30 Safety Injection Pump 2-1:

Bolting >2" diameter Safety Injection Pump I-1 Safety Injection Pump 2-1 8 Studs >2" dia. (Items I thru 7 & 11) 8 Studs >2" dia. (Items I thru 7 & I1)

U :2.3-2 UT I

U2: 2.3-2 UT I

Page 178

ASME Sec. Xl Code Category C-F-1 and C-F-2 ITEM PARTS EXAMINED COMP/LINE WELD/COMP NO.

ISI DWG.

NDE PER.

LINE-RELIEF BLOCK NOTES TOTL-%

REQ.

Note: Tables B-F, B-J, C-F-I, and C-F-2 have been replaced by Rl-ISI Program located under Tab-3 of this Program Plan.

Pa~e 179

  • 0 ASME Sec. X1 Code Category C-G S

PRGAM PAN D

ial C

an 3rInevlR I

ITEM PARTS EXAMINED COMP/LINE WELD/COMP NO.

ISI DWG.

NDE PER.

LINE-TOTL-%

RELIEF BLOCK REQ.

NOTES C6. 10 Residual Heat Removal Pumps Casing Welds Safety Injection Pumps Casing Welds Centrifugal Charging Pump 1-1 and 1-2 Casing Welds Centrifugal Charging Pump 1-3 Casing Welds C6.10 Residual Heat Removal Pumps Casing Welds Safety Injection Pump Casing Welds Centrifugal Charging Pump 2-1 Casing Welds Centrifugal Charging Pump 2-2 Casing Welds Centrifugal Charging Pump 2-3 Casing Welds C6.20 Valve Body Welds: None Unit I or Unit 2 None None None None None None None None UI: 2.3-1 U 1: 2.3-2 UI: 2.3-3 U1: 2.3-4 CCP 1-1 casing changed from CS to SS 1RI6.

Centrifugal Pump installed IRI 5 None None None None None None None None None None None U2:2.3-1 U2: 2.3-2 U2: 2.3-3 U2: 2.3-3 U2: 2.3-4 CCP 2-2 casing changed from CS to SS 2R16.

Centrifugal Pump installed 2R14 N

None Page 180

ASME Sec. XI Code Category C-H Dablo Sc.no 3rXl tra Rv ITEM PARTS EXAMINED COMP/LINE WELD/COMP NO.

ISI DWG.

NDE PER. LINE-TOTL RELIEF NOTES REQ.

C7.10 Due to difference in format, pressure test tables follow Augmented Exams.

Page 181

ASME Sec. Xl Code Category D-A SPRGAM PLANA ITEM PARTS EXAMINED COMP/LINE WELD/COMP NO.

ISI DWG.

NDE PER.

LINE-TOTL-%

RELIEF BLOCK REQ.

NOTES NOTE: Class 3 Welded Attachments are included with the support structure (Category F-A) when examination is required.

VT-I Exam Also Required if Deformation of Support Member Seen At Any Time Page 182

ASME Sec. Xl Code Category D-B P

PRG AM PLA NA Dial eavo 3r nevlRv ITEM PARTS EXAMINED COMP/LINE WELD/COMP NO.

IS1 DWG.

NDE PER.

D2.10 Due to difference in format, pressure test tables follow Augmented Exams.

LINE-RELIEF BLOCK TOTL-%

REQ.

NOTES Page 183

ASME Sec. XI 9

  • Category F-A S

PRGAM PAN Dial Cavn3dItevlRv ITEM PARTS EXAMINED COMP/LINE WELD/COMP NO.

ISI DWG.

NDE PER.

LINE-TOTL-%

RELIEF BLOCK REO.

NOTES F1.10A Fl IOC F1.20A FI.20B FI.20C F1.30A FI.30B FI.30C 5300A Class 1, One-Directional Supports - 25% Selected*

Class 1, Multi-Directional Supports - 25% Selected*

Class 1, Supports That Allow Thermal Movement, including Snubber Attachments - 25% Selected*

Class 2, One-Directional Supports - 15% Selected*

Class 2, Multi-Directional Supports - 15% Selected*

Class 2, Supports That Allow Thermal Movement, including Snubber Attachments-15% Selected*

Class 3, One-Directional Supports - 10% Selected*

Class 3, Multi-Directional Supports - 10% Selected*

Class 3, Supports That Allow Thermal Movement, including Snubber Attachments - 10% Selected*

Snubbers-All Snubbers 100% Examined per ASME/ANSI OM, ISTD using VT-3 method NOTE: Rupture restraints are not supports for the pressure boundary.

NOTE: Common Unit items are assigned to Unit 1; for multiple components, Loop 2 or the lowest numbered is generally selected.

I

  • Individual types % approximate.- Cumulative %

exceeds requirements.

  • All Pipe Supports Scheduled per IWF-2420(a) as practicable Page 184

ASME Sec.

Category F-A Dial Ca n3dInevlRv I

ITEM PARTS EXAMINED COMP/LINE WELD/COMP NO.

SI DWG.

NDE PER.

LINE-TOTL-%

RELIEF BLOCK REO.

NOTES Unit I NOTE: Unit 2 supports begin on Page 104 of this section Class 1 Reactor Vessel Unit 1 Support -

Reactor Vessel 1-1 Vessels Nozzle pad blocks to structure Pressurizer Unit 1 Support Pressurizer 1-1 Steam Generator 1-1 Steam Generator (Primary Side) Support 1-1 Steam Generator 1-2 Steam Generator (Primary Side) Support 1-2 Steam Generator 1-3 Steam Generator (Primary Side) Support 1-3 End Cl. 1 Steam Generator 1-4 Steam Generator Vessels (Primary Side) Support 1-4 4 Supports Support Skirt and Support Structure Not Selected Support Structure Not Selected Not Selected UI: 1.1-1 VT-3 2

Welded attachments are Category B-K.

Welded attachments are Category-13-K.

Ut: 1.2-1 Ut: 1.3-1 Ut: 1.3-1 Ut: 1.3-1 Ut: 1.3-1 VT-3 3

VT-3 2

Includes pin columns, lateral supports, braces Class 1 Reactor Coolant Pump Pumps I-I Support Reactor Coolant Pump 1-2 Support Reactor Coolant Pump 1-3 Support End Cl. 1 Reactor Coolant Pump Pumps 1-4 Support Reactor Coolant Pp 1-1 Reactor Coolant Pp 1-2 Reactor Coolant Pp 1-3 Reactor Coolant Pp 1-4 Not Selected Support Structure Not Selected Not Selected Ut: 1.5-1 Ut: 1.5-1,,

VT-3 Ut: 1.5-1 U1: 1.5-1 2

Includes columns, lateral supports, braces, foot afichorages.

Class 1 Reactor Coolant Out Loops Piping 1, 2, 3 and 4 (support)

Reactor Coolant Crossover Loops 1,2,3, and 4

  • 1-, *2-, *3-and No supports
  • 4-29SPL
  • 5-, *6-, *7-, and *8-Supports deleted per 31SPL SGRP DCN Ut: 1.4 1.4-4, UI: 1.4 1.4-4 Class 1 Pipe Supports Scheduled per IWF-2420(a), as Practicable Supports A and B attachment points removed per SGRP DCN Page 185

ASME Sec. X1 Code Category F-A S PROGAM PLAN

- ial s avn3dInevlRv I

ITEM PARTS EXAMINED COMP/LINE WELD/COMP NO.

ISI DWG.

NDE PER.

LINE-TOTL-%

RELIEF BLOCK REQ.

NOTES Reactor Coolant Pump Disch Loop 1, 2, 3 and 4 Pressurizer Surge Line Support Pressurizer Surge Line Support Pressurizer Surge Line Support Pressurizer Surge Line Supp'ort Pressurizer Surge Line Support Hot Leg Recirc Before V-8702 Support Hot Leg Recirc Before V-8702 Support Hot Leg Recirc Before V-8702 Support Hot Leg Recirc Before V-8702 Support Hot Leg Recirc Before V-8702 Support Hot Leg Recirc Before V-8702 Support Loop 4 Hot Leg Before V-8701 Support Loop 4 Hot Leg Before V-8701 Support Loop 4 Hot Leg Before V-8701 Support

  • 9.-,
  • 10..,
  • 11-and
  • 12..27.5SPL
  • 16..14SPL
  • 16..14SPL
  • 16-445PL
  • 16-14SPL
  • 16-14SPL S6.109-I4SPL S6-109-14SPL S6-109-14SPL S6-109-I4SPL S6-109-14SPL S6-109-14SPL S6-1665-14SPL S6-1665-14SPL S6-1665-14SPL No supports51-24V 10-13SL 10-86SL 51-23V 51-25SL 56N-6V 56N-8V 12-3SL 56N-7V 12-144SL 12-226SL 56N-4R 56N-5V 56N-3V UI: 1.4-1,-

1.4-4 UI: 1.4-5 VT-3 U]: 1.4-5 VT-3 UI: 1.4-5 U1: 1.4-5 VT-3 Ul: 1.4-5 U1: 1.4-6 U3: 1.4-6 UI: 1.4-6 Ul: 1.4-6 VT-3 Ul: 1.4-6 VT-3 U1: 1.4-6 U1: 1.4-7 VT-3 Ul: 1.4-7 VT-3 Ul: 1.4-7 3

2 2

3 I

-3 Page 186

00 ASME Sec. Xl Code Category F-A ITEM PARTS EXAMINED COMP/LINE WELD/COMP NO.

ISI DWG.

NDE PER.

LINE-RELIEF BLOCK NOTES TOTL-%

REQ.

Loop 4 Hot Leg Before S6-1665-14SPL 12-2SL Ul: 1.4-7 V-8701 Support Loop 4 Hot Leg Before S6-1665-14SPL 12-146SL UI: 1.4-7 V-8701 Support Accumulator Injection S6-253-10SPL+

10-5SL Ul: 1.4-8 VT-3 2

Loop 1 Support Accumulator Injection S6-253-10SPL+.

10-6SL UI: 1.4-8 Loop 1 Support Accumulator Injection S6-253-10SPL+

52-23V Ul: 1.4-8 Loop 1 Support Accumulator Injection S6-253-I0SPL+

10-84R Ul: 1.4-8 Loop 1 Support Accumulator Injection

$6-253-10SPL+

51-27R Ul: 1.4-8 Loop I Support Accumulator Injection S6-254-10SPL+

10-4SL UI: 1.4-9 VT-3 Loop 2 Support Accumulator Injection S6-254-10SPL+

52-24V UI: 1.4-9 Loop 2 Support Accumulator Injection S6-254-10SPL+

10-89SL Ul: 1.4-9 Loop 2 Support Accumulator Injection

$6-255-10SPL+

12-139SL UI: 1.4-10 VT-3 3

Loop 3 Support Accumulator Injection S6-255-10SPL+

57N-4V Ul: 1.4-10 Loop 3 Support Accumulator Injection

$6-256-10SPL+

57N-2V Ul: 1.4-11 Loop4 Support Accumulator Injection

$6-256-10SPL+

12-99R Ul: 1.4-11 Loop 4 Support Accumulator Injection

$6-256-10SPL+

12-98R Ul: 1.4-11 Loop 4 Support Page 187

ASME Sec. XI Cod Category F-A ITEM PARTS EXAMINED COMP/LINE WELD/COMP NO.

ISI DWG.

NDE PER.

LINE-RELIEF BLOCK NOTES TOTL-%

REQ.

Accumulator Injection S6-256-1OSPL+

12-11R Ut: 1.4-11 Loop 4 Support SIS to RCS Loop 1 Hot Leg S6-2575-8 10-34SL Ut: 1.4-12 Support SIS to RCS Loop 1 Hot Leg S6-2575-8 40-27R UI: 1.4-12 Support SIS to RCS Loop 2 Hot Leg S6-2576-8 10-31R U1: 1.4-12 VT-3 2

Support SIS to RCS Loop 2 Hot Leg S6-2576-8 10-26SL Ut: 1.4-12 Support SIS to RCS Loop 2 Hot Leg S6-2576-8 40-29R UI: 1.4-12 VT-3 3

Support Safety Inj Loop I Hot Leg

$6-235-6SPL+

10-24SL Ut: 1.4-13 VT-3 I

Support Safety lnj Loop 1 Hot Leg S6-235-6SPL+

10-25SL Ut: 1.4-13 Support Safety Inj Loop 1 Hot Leg

$6-235-6SPL+

10-85R Ut: 1.4-13 Support Safety Inj Loop 1 Hot Leg

$6-235-6SPL+

52-27V Ut: 1.4-13 Support Safety Inj Loop 1 Hot Leg

$6-235-6SPL+

10-23R U1:¶1.4-13 Support Safety Inj Loop 2 Hot Leg

$6-236-6SPL+

10-22R U t: 1.4-14 VT-3 2

Support Safety Inj Loop 2 Hot Leg

$6-236-6SPL+

10-21SL Ut: 1.4-14 Support Safety Inj Loop 2 Hot Leg

$6-236-6SPL+

10-30R Ut: 1.4-14 VT-3 3

Support Safety Inj Loop 2 Hot Leg

$6-236-6SPL+

10-87R Ut: 1.4-14 VT-3 3

Support Page 188

ASME Sec. Xi Category F-A ITEM PARTS EXAMINED COMP/LINE WELD/COMP NO.

ISI DWG.

NDE PER.

LINE-RELIEF BLOCK NOTES TOTL-%

REQ.

Safety Inj Loop 2 Hot Leg

$6-236-6SPL+

10-133R U1: 1.4-14 VT-3 3

Support Safety Inj Loop 3 Hot Leg

$6-237-6SPL+

12-137SL Ut: 1.4-15 VT-3 3

Support Safety Inj Loop 3 Hot Leg S6-237-6SPL+

57N-12R Ut: 1.4-15 Support Safety Inj Loop 3 Hot Leg S6-237-6SPL+

57N-17R UI: 1.4-15 Support Safety Inj Loop 3 Hot Leg

$6-237-6SPL+

12-17R UI: 1.4-15 Support Safety Inj Loop 3 Hot Leg

$6-237-6SPL+

12-143R Ut: 1.4-15

,Support Safety Inj Loop 3 Hot Leg

$6-237-6SPL+

12-142R Ul: 1.4-15 Support Safety Inj Loop 3 Hot Leg

$6-237-6SPL+

12-19R Ul: 1.4-15 Support Safety Inj Loop 3 Hot Leg

$6-237-6SPL+

57N-14V Ul: 1.4-15 Support Safety 1nj Loop 4 Hot Leg

$6-238-6SPL+

12-154R UI:A1.4-6 Support Safety Inj Loop 4 Hot Leg

$6-238-6SPL+

56N-17R Ut: 1.4-16 Support Safety lnj Loop 4 Hot Leg

$6-238-6SPL+

12-14R Ut: 1.4-16 Support Safety Inj Loop 4 Hot Leg S6-238-6SPL+

56N-16V

  • Ut: 1.4-16 Support RHR Pp' 1-I Inj Cold Leg 1

$6-3844-6SPL+

42-59R Ut: 1.4-17 Support RHRPp 1-1 Inj Cold Leg-1

$6-3844-6SPL+

11-23R Ut: 1.4-17 Support

.Page 189

ASME Sec. Xlie Category F-A ITEM PARTS EXAMINED COMP/LINE WELD/COMP NO.

ISI DWG.

NDE PER.

LINE-RELIEF BLOCK NOTES TOTL-%

REQ.

RHR Pp I-I lnj Cold Leg I S6-3844-6SPL+

42-40R UI: 1.4-17 Support RHR Pp 1-1 lnj Cold Leg I S6-3844-6SPL+

I 1-89R Ul: 1.4-17 Support RHR Pp I-I lnj Cold Leg I S6-3844-6SPL+

42-41V UI: 1.4-17 Support SI Pps Cold Leg Loop I Recirc S6-3855-2SPL+

No Supports U : 1.4-17 (support)

RHR Pp 1-1 Inj Cold Leg 2

$6-3845-6SPL+

11-82SL UI: 1.4-18 VT-3 2

Support RHR Pp 1-1 Inj Cold Leg 2 S6-3845-6SPL+

11-16SL U1: 1.4-18 Support RHR Pp I-I Inj Cold Leg 2 S6-3845-6SPL+

I I-79SL UV: 1.4-18 Support RHR Pp 1-1 Inj Cold Leg2 S6-3845-6SPL+

11-15SL U 1: 1.4-18 VT-3 I

Support RHR Pp I-I Inj Cold Leg 2 S6-3845-6SPL+

11-81SL UI: 1.4-18 Support RHR Pp I-I Inj Cold Leg 2

$6-3845-6SPL+

42-43V U 1: 1.4-18 VT-3 2

Support RHR Pp 1-1 Inj Cold Leg 2

$6-3845-6SPL+

42-44V U 1: 1.4-18 VT-3 3

Support RHR Pp 1-1 lnj Cold Leg 2

$6-3845-6SPL+

I I-80SL U I: 1.4-18 Support RHR Pp I-I Inj Cold Leg 2

$6-3845-6SPL+

42-42V UI: 1.4-18 Support RHR Pp 1-1 Inj Cold Leg 2

$6-3845-6SPL+

42-54V UI: 1.4-18 Support SI Pps Cold Leg Loop 2 Recirc

$6-3856-2SPL+

No Supports Ul: 1.4-18 (support)

Page 190

ASME Sec. X1 Code Category F-A ITEM PARTS EXAMINED COMP/LINE WELD/COMP NO.

ISI DWG.

NDE PER.

LINE-RELIEF BLOCK NOTES TOTL-%

REQ.

RI-R Pp 1-2 lnj Cold Leg 3 S6-3846-6SPL+

13-7SL UI: 1.4-19 Support RHR Pp 1-2 lnj Cold Leg 3 S6-3846-6SPL+

13-9SL U 1: 1.4-19 Support RHR Pp 1-2 Inj Cold Leg 3 S6-3846-6SPL+

58N-59V Ul: 1.4-19 Support RHR Pp 1-2 Inj Cold Leg 3 S6-3846-6SPL+

13-6R UI: 1.4-19 Support RHR Pp 1-2 Inj Cold Leg 3 S6-3846-6SPL+

13-5R UI: 1.4-19 Support RHR Pp 1-2 Inj Cold Leg 3 S6-3846-6SPL+

58N-31V U1: 1.4-19 Support RHR Pp 1-2 lnj Cold Leg 3 S6-3846-6SPL+

13-8R UI: 1.4-19 Support RHR Pp 1-2 Inj Cold Leg 3

$6-3846-6SPL+

58N-32V UI: 1.4-19 Support RHR Pp 1-2 Inj Cold Leg 4

$6-3847-6SPL+

58N-62R U I: 1.4-20 Support RHR Pp 1-2 Inj Cold Leg 4

$6-3847-6SPL+

58N-60R U 1: 1.4-20 Support RHR Pp 1-2 lnj Cold Leg 4

$6-3847-6SPL+

13-30R Ul: 1.4-20 Support RHR Pp 1-2 Inj Cold Leg 4

$6-3847-6SPL+

13-12R UI: 1.4-20 Support RHR Pp 1-2 Inj Cold Leg 4

$6-3847-6SPL+

58N-64V UI: 1.4-20 Support RHR Pp 1-2 Inj Cold Leg 4

$6-3847-6SPL+

13-27R U 1: 1.4-20 Support RHR Pp 1-2 Inj Cold Leg 4

$6-3847-6SPL+

13-14R U 1:I4-20 Support Page 191

ASME Sec. XI Code Category F-A ITEM PARTS EXAMINED COMP/LINE WELD/COMP NO.

1SI DWG.

NDE PER.

LINE-RELIEF BLOCK NOTES

-TOTL-%

REQ.

RHR Pp 1-2 Inj Cold Leg 4

$6-3847-6SPL+

58N-65V UI: 1.4-20 Support Pressurizer RV-8010A Inlet S6-729-6SPL 48-IR UI: 1.4-21 VT-3 I

Support Pressurizer RV-8010A Inlet S6-729-6SPL I1-44SL UI: 1.4-21 VT-3 2

Support Pressurizer RV-8010B Inlet

$6-728-6SPL 11-43SL UI: 1.4-22 VT-3 2

Support Pressurizer RV-8010B Inlet S6-728-6SPL 46-12R UI: 1.4-22 Support Pressurizer RV-80t0C Inlet S6-727-6SPL 11-42SL UI: 1.4-23 Support Pressurizer RV-8010C Inlet S6-727-6SPL 48-17R U 1: 1.4-23 Support Pressurizer Power RV Inlet S6-730-6SPL 48-26CS U1: 1.4-24 VT-3 Support Pressurizer Power RV Inlet

$6-730-6SPL 11-130SL U 1: 1.4-24 Support -

Pressurizer Power RV Inlet S6-730-6SPL 11-21SL U1: 1.4-24 Support Pressurizer RV PCV-455C Inlet S6-4081-4SPL 11-22SL Ul: 1.4-24 Support Pressurizer Power RV S6-1171-3SPL+

11-14SL UI: 1.4-24 PCV-474 Support Pressurizer Power RV S6-1171-3SPL+

11-96SL U1: 1.4-24 PCV-474 Support Pressurizer Power RV S6-1171-3SPL+

11-97SL UI: 1.4-24 PCV-474 Support Pressurizer Power RV

$6-1171-3SPL+

11-153SL U1: 1.4-24 PCV-474 Support Page 192

ASME Sec. X 9 ICategory F-A ial avo 3r nevlRvS ITEM PARTS EXAMINED COMP/LINE WELD/COMP NO.

ISI DWG.

NDE PER.

LINE-RELIEF BLOCK NOTES TOTL-%

REQ.

Pressurizer Power RV,

S6-1171-3SPL+

11-154SL Ul: 1.4-24 PCV-474 Support Pressurizer Power RV

$6-l 171-3SPL+

11-155SL UI: 1.4-24 VT-3 3

PCV-474 Support Pressurizer Power RV

$6-1171-3SPL+

11-90R Ut: 1.4-24 PCV-474 Support Pressurizer Power RV S6-1171-3SPL+

48-25V Ul: 1.4-24 PCV-474 Support Pressurizer Power RV S6-1172-3SPL+

48-27V U1: 1.4-24 VT-3 I

PCV-455C Support Pressurizer Power RV S6-1172-3SPL+

48-29A UI: 1.4-24 VT-3 2

PCV-455C Support Pressurizer Power RV S6-1172-3SPL+

11-i48R Ul: 1.4-24 VT-3 3

PCV-455C Support Pressurizer Power RV

$6-1172-3SPL+

11-149R UI: 1.4-24 VT-3 3

PCV-455C Support Pressurizer Power RV

$6-1172-3SPL+

11-131SL Ut: 1.4-24 PCV-455C Support Loop I Spray Line Support

$6-13-4SPL 1l1-105SL Ul: 1.4-25 VT-3 3

Loop 1 Spray-Line Support

$6-13-4SPL 42-73R Ul: 1.4-25 Loop I Spray Line Support

$6-13-4SPL 42-8R Ut: 1.4-25 Loop 1 Spray Line Support

$6-13-4SPL 42-61R UI: 1.4-25 Loop I Spray Line Support

$6-13-4SPL 42-23A U1: 1.4-25 Loop 1 Spray Line Support

$6-13-4SPL 42-9R U1: 1.4-25 Page 193

ASME Sec. XIt Category F-A ITEM PARTS EXAMINED COMP/LINE WELD/COMP NO.

ISI DWG.

NDE PER.

LINE-RELIEF BLOCK NOTES TOTL-%

REQ.

Loop I Spray Line Support S6-13-4SPL 42-72V UI: 1.4-25 Loop I Spray Line Support S6-13-4SPL 42-10R UI: 1.4-26 Loop I Spray Line Support

$6-13-4SPL 42-71A UI: 1.4-26 Loop I Spray Line Support

$6-13-4SPL 42-70R UI: 1.4-26 Loop 1 Spray Line Support S6-13-4SPL 52-33A U 1: 1.4-26 Loop I Spray Line Support

$6-13-4SPL 52-35R Ul: 1.4-26 Loop I Spray Line Support

$6-13-4SPL 52-34V.

UI: 1.4-27 Loop I Spray Line Support

$6-13-4SPL 52-32R UI: 1.4-27 Loop I Spray Line Support

$6-13-4SPL 52-39R UI: 1.4-27 L-Loop I Spray Line Support

$6-13-4SPL 52-14V UI: 1.4-27 Loop I Spray Line Support

$6-13-4SPL 52-13R U1: 1.4-27 Loop I Spray Line Support

$6-13-4SPL 52-12V UI: 1.4-27 Loop 1 Spray Line Support

$6-13-4SPL 11-110SL U1: 1.4-27 VT-3 3

Loop 2 Spray Line Support

$6-14-4SPL 52-19V UI: 1.4-28 VT-3 1

Loop 2 Spray Line Support

$6-14-4SPL 42-63R UI 1:.4-25 VT-3 1

Page 194

ASME Sec. XI Code Category F-A ITEM PARTS EXAMINED COMP/LINE WELD/COMP NO.

ISI DWG.

NDE PER.

LINE-RELIEF BLOCK NOTES TOTL-%

REQ.

Loop 2 Spray Line Support S6-14-4SPL 10-128SL U1: 1.4-28 Loop 2 Spray Line Support S6-14-4SPL 10-129SL U1: 1.4-28 Loop 2 Spray Line Support

$6-14-4SPL 10-131 SL UJ: 1.4-28 Loop 2 Spray Line Support

$6-14-4SPL 11-136SL

. U1: 1.4-28 Loop 2 Spray Line Support

$6-14-4SPL 11-135SL Ul: 1.4-28 Loop 2 Spray Line Support

$6-14-4SPL 52-18R UI: 1.4-28 VT-3 2

Loop 2 Spray Line Support

$6-14-4SPL 11-19R UI: 1.4-25 VT-3 2

Loop 2 Spray Line Support S6-14-4SPL 42-62R Ul: 1.4-25 VT-3 2

Loop 2 Spray Line Support

$6-14-4SPL 10-41R UI: 1.4-28 VT-3 2

Loop 2 Spray Line Support

$6-14-4SPL 11-17SL Ul: 1.4-25 VT-3 1

Loop 2 Spray Line Support

  • 6-14-4SPL 11-18SL Ul: 1.4-25 Loop 2 Spray Line Support

$6-14-4SPL 11-139SL Ul: 1.4-25 Loop 2 Spray Line Support

$6-14-4SPL 52-16R Ul: 1.4-28 Loop 2 Spray Line Support

$6-14-4SPL 52-17R Ul: 1.4-28 Loop 2 Spray Line Support

$6-14-4SPL 11-137R UI: 1.4-28 VT-3 3

Page 195

ASME Sec. X1 Cl ategory F-A Dial ean3dInevlRv I

ITEM PARTS EXAMINED COMP/LINE WELD/COMP NO.

ISI DWG.

NDE PER.

LINE-RELIEF BLOCK NOTES TOTL-%

REQ.

Loop 2 Spray Line Support

$6-14-4SPL 52-36V UI: 1.4-28 Loop 2 Spray Line Support

$6-14-4SPL 11-138SL Ul: 1.4-28 Pressurizer Spray Line Support S6-15-4SPL 42-5R Ul: 1.4-29 VT-3 I

Pressurizer Spray Line Support S6-15-4SPL 11-142SL Ul: 1.4-29

  • VT-3 2

Pressurizer Spray Line'Support S

$6-15-4SPL 11-143R UI: 1.4-29 VT-3 I

Pressurizer Spray Line Support

$6-15-4SPL 11-24SL UI: 1.4-29 Pressurizer Spray Line Support

$6-15-4SPL 42-3R UI: 1.4-29 VT-3 Pressurizer Spray Line Support S6-15-4SPL 42-75R UI: 1.4-29 Pressurizer Spray Line Support S6-15-4SPL 43-IR Ut: 1.4-29 VT-3 Pressurizer Spray Line Support "6-15-4SPL 42-4V Ul: 1.4-29 Pressurizer Spray Line Support S6-15-4SPL 42-MOR UI: 1.4-29 VT-3 Pressurizer Spray Line Support

$6-15-4SPL 42-64V U1: 1.4-29 Pressurizer Spray Line Support S6-15-4SPL 11-144R Ut: 1.4-29 VT-3 Pressurizer Spray Line Support

$6-15-4SPL 43-1OCS Ut: 1.4-29 VT-3 3

Pressurizer Spray Line Support

$6-15-4SPL 48-22CS Ut: 1.4-29 Page 196

ASME Sec. X9

,Category F-A S PROGRA PAN Dial Can 3rInevlR

.I ITEM PARTS EXAMINED Pressurizer Spray Line Support Loop I Stub [3" former RTD connection](support)

Loop 2 Stub [3" former RTD connection](support)

Loop 3 Stub [3" former RTD connection](support)

Loop 4 Stub [3" former RTD connection](support)

Charging Line Loop 4 Support Charging Line Loop 3 Support Boron lnj Cold Leg Hdr Support Boron lnj Cold Leg Hdr Support Boron Inj Cold Leg Hdr Support Boron Ilj Cold Leg Hdr Support Boron Inj Cold Leg Hdr Support Boron Inj Cold Leg Hdr Support Boron lnj Cold Leg Hdr Support Boron Inj Cold Leg Hdr (support)

COMP/LINE

$6-15-4SPL

$6-1141-3SPL

$6-1147-3SPL

$6-1153-3SPL S6-1158-3SPL

$6-246-3SPL

$6-50-3SPL S6-1995-3 S6-1995-3 S6-1995-3 S6-1995-3 S6-1995-3 S6-1995-3 S6-1995-3 S6-1016-3 WELD/COMP NO.

ISI DWG.

NDE PER.

LINE-TOTL-%

RELIEF BLOCK REQ.

NOTES 11-15OR No Supports No Supports No Supports No Supports 57N-8V 56N-132V 57N-34R 57N-33R 12-94SL 57N-35R 57N-76R 12-102R 57N-102V No Supports Ut: 1.4-29 Ut: 1.4-30 U]: 1.4-31 UI: 1.4-32 Ut1-1.4-33 Ut: 1.4-34 Ut: 1.4-35 Ul-1.4-36 Ut: 1.4-36 Ut: 1.4-36 Ut: 1.4-36 U]: 1.4-36 Ul: 1.4-36 Ut: 1.4-36 Ut: 1.4-36 VT-3 VT-3 VT-3 2

Page 197

ASME Sec. X 9 Category F-A ITEM PARTS EXAMINED COMP/LINE WELD/COMP NO.

ISI DWG.

NDE PER.

LINE-RELIEF BLOCK NOTES TOTL-%

REQ.

Letdown Line Loop 2 Support S6-24-3SPL 39-25R Ul: 1.4-37 Letdown Line Loop 2 Support S6-24-3SPL 52-3V U1: 1.4-37 VT-3 I

Letdown Line Loop 2 Support S6-24-3SPL 52-4R Ul: 1.4-37 Letdown Line Loop 2 Support S6-24-3SPL 52-31R Ul: 1.4-37 Letdown Line Loop 2 Support S6-24-3SPL 52-9V Ut: 1.4-38 Letdown Line Loop 2 Support

$6-24-3SPL 52-41R UI: 1.4-38 Pressurizer Power RV

$6-1195-3SPL+

11-94SL Ut: 1.4-39 VT-3 3

PCV-456 Support Pressurizer Power RV S6-1195-3SPL+

11-95SL U1: 1.4-39 VT-3 2

PCV-456 Support Pressurizer Power RV S6-1195-3SPL+

11-124SL Ut: 1.4-39 PCV-456 Support Pressurizer Power RV

$6-1195-3SPL+ 125SL Ut: 1.4-39 PCV-456 Support Pressurizer Power RV

$6-1195-3SPL+

11-126SL Ut: 1.4-39 PCV-456 Support Pressurizer Power RV S6-1195-3SPL+

11-127SL Ut: 1.4-39 PCV-456 Support Pressurizer Power RV

$6-1195-3SPL+

11-132SL Ut: 1.4-39 PCV-456 Support Pressurizer Power RV

$6-1195-3SPL+

48-43R UI: 1.4-39 PCV-456 Support Charging Line Aux Spray Support S6-51-2SPL+

181-29 U1: 1.4-40B VT-3 2

Page 198

ASME Sec. XI Code Category F-A Diabl savn3dItevlRv ITEM PARTS EXAMINED COMP/LINE WELD/COMP NO.

ISI DWG.

NDE PER.

LINE-TOTL-%

RELIEF BLOCK REQ.

NOTES Charging Line Aux Spray Support S6-51-2SPL+

Charging Line Aux Spray Support

$6-5 I-2SPL+

Charging Line Aux Spray Support S6-51-2SPL+

Charging Line Aux Spray Support S6-51-2SPL+

Charging Line Aux Spray Support S6-51-2SPL+

Charging Line Aux Spray Support S6-51-2SPL+

Charging Line Aux Spray Support

$6-51-2SPL+

Charging Line Aux Spray Support

$6-51-2SPL+

Charging Line Aux Spray Support S6-51-2SPL+

Charging Line Aux Spray Support

$6-51-2SPL+

Charging Line Aux Spray Support

$6-51-2SPL+

Charging Line Aux Spray Support

$6-51-2SPL+

Charging Line Aux Spray Support

$6-51-2SPL+

Charging Line Aux Spray Support

$6-51-2SPL+

Charging Line Aux Spray Support

$6-51-2SPL+

181-35 2152-13 2152-72 2180-15 43-3R 2152-14 181-30 2152-19 2180-42 (V) 22-398R 23-2A 22-70R 181-31 2185-19 22-399R UI: 1.4-40B UI: 1.4-40A UI: 1.4-40A UI: 1.4-41 UI: 1.4-41 U1: 1.4-40A U1: 1.4-40B UI: 1.4-40A U1: 1.4-41 UI: 1.4-41 UI: 1.4-40A U1: 1.4-40B U1: 1.4-40B UI: 1.4-41 Ul: 1.4-41 VT-3 VT-3 3

VT-3 2

Page 199

ASME Sec. X1 Code Category F-A IS PRGAM PLAN Dial Cavo 3re nevlRv ITEM PARTS EXAMINED ý ISI DWG.

COMP/LINE gCharging Line Aux Spray Support Charging Line Aux Spray Support Charging Line Aux Spray Support Charging Line Aux Spray Support Charging Line Aux Spray Support Charging Line Aux Spray Support Charging Line Aux Spray Support Charging Line Aux Spray Support Charging Line Aux Spray Support Charging Line Aux Spray Support Charging Line Aux Spray Support Charging Line Aux Spray Support Charging Line Aux Spray (support)

Reac Cool Pp 1-1 Seal Wtr In Support Reac Cool Pp 1-1 Seal Wtr In Support S6-51-2SPL+

S6-51-2SPL+

S6-51-2SPL+

$6-51-2SPL+

$6-51-2SPL+

$6-51-2SPL+

S6-51-2SPL+

S6-51-2SPL+

S6-51-2SPL+

$6-51-2SPL+

S6-51-2SPL+

S6-51-2SPL+

$6-4532-2SPL+

S6-54-2 S6-54-2 WELD/COMP NO.22-62R 23-IA 2180-16 181-28 2152-15 43-2R 2152-9 2152-17 2180-18 2152-12 2152-18 2152-63 22-351R 22-211SL 46-17 NDE PER.

LINE-TOTL-%

RELIEF BLOCK REQ.

NOTES Ul: 1.4-40A Ut: 1.4-40B Ul.: 1.4-41 UI: 1.4-40B Ul: 1.4-40A Ul: 1.441 Ul: 1.4-40A U1: 1.4-40A UI: 1.4-41 U1: 1.4-40A U1: 1.4-40A U1: 1.4-40A Ul: 1.4-40B UI: 1.4-42 Ul: 1.4-42 VT-3 2

VT-3' 3

VT-3 VT-3 VT-3 3

3 3

Page 200