From:

Vaidya, Bhalchandra Sent:

Thursday, January 05, 2012 9:02 AM To:

'Cornelius Coddington'; 'Rochester, Margaret'; 'Petrilla III, John J' Cc:

Salgado, Nancy; Lingam, Siva; Boyle, Patrick; Purtscher, Patrick; Sheng, Simon

Subject:

Request for Additional Information, ME7381, Relief Request 3RR-18 Re:

Successive Inspections of AF Weld (0-120 degrees)

Subject:

Proposed Relief Request No. 3RR18 for AF Weld (Shell Course to Vertical Flange Weld (0-120 degrees),

for Successive Inspections in the Third 10-Year Inservice Inspection Program, Dated October 03, 2011 (PLA-6753)

Based on its review of the Relief Request, the NRC staff has determined that additional information is required to complete its review. The Request for Additional Information (RAI) is provided below:

==============================================================

REQUEST FOR ADDITIONAL INFORMATION ON SUSQUEHANNA, UNIT 2 REQUEST FOR RELIEF 3RR18 DOCKET NO. 50-388 (ME7381)

RAI 1

Provide a complete description of the subject weld (inspection category and item no.), the materials of construction, and its location in the system.

=====================================================

The response to the above RAI is needed by January 15, 2012, in order to support the requested completion date for the Relief Request.

Please contact me ASAP, if PPL needs clarification of the questions in the above RAI.

Bhalchandra K. Vaidya Licensing Project Manager NRC/NRR/DORL/LPL1-1 (301)-415-3308 (O) bhalchandra.vaidya@nrc.gov