Riverkeeper (Riv) Pre-Filed Evidentiary Hearing Exhibit RIV000027, Entergy Operations, Inc., Condition Report List, IPEC00092551 (Condition Report List 2)
ML11356A033
Person / Time
Site: Indian Point  Entergy icon.png
Issue date: 12/22/2011
From: Caputo C
- No Known Affiliation
To:
Atomic Safety and Licensing Board Panel
SECY RAS
Shared Package
ML11356A026 List:
References
RAS 21601, 50-247-LR, 50-286-LR, ASLBP 07-858-03-LR-BD01
Download: ML11356A033 (28)


Text

RIV000027 Submitted: December 22, 2011 Condition Report search for the word "Wall Thinning" associated with Contention 11, FAC The attached document is a summary report using words Wall Thinning of all condition reports; no culling for relevance has been done. This is not the approach taken for every other word search where the condition reports were reviewed and the actual CR was sent for your consideration. The reason for this is that there are 171 condition reports, and a brief scanning of the CRs indicating they seem to be relevant.

If you need a print out any condition report, please let me know and we will send it to you.

Charlie Caputo 914 734 6656 IPEC00092551

Page 37 of 63

"'U Entergy Operations, Inc. Condition Report List September29, 200810:12 AM m

()

0 0 CR-IP3-2003-01771 Significance: C REVIEW & CORRECT Reportability:

0

<D Operability: EQUIPMENT OPERABLE CR Status: Closed on July 03, 2003 I'V CJl Classification Code: NON-SIGNIFICANT CJl I'V

Description:

During a FAC examination (WO IP3-02-23328, 03-PT -11 ), wall thinning was noted on piping upstream and downstream of MS-FCV-1158.

The remaining wall thickness is sufficient to last through R13, per calculation IP3-CALC-MULT-02515.

No piping repair/replacement is required. No work will be required on this component during R12 Responsible Dept: WPO Eng Programs Mgmt CA&A

Contact:

R Perra Originated: 04/02/2003 by Hartjen,Harry G, WPO Eng Programs Staff Affected Systems: Affected Equipment:

CR-IP3-2003-01 831 Significance: C REVIEW & CORRECT Reportability:

Operability: EQUIPMENT OPERABLE CR Status: Closed on July 28, 2003 Classification Code: NON-SIGNIFICANT

Description:

During a FAC examination (WO 13-010467401, 03-PT-08), wall thinning was noted on piping upstream and downstream of MS-FCV-1154.

The remaining wall thickness is sufficient to last through R13, per calculation IP3-CALC-MUL T-03085.

No piping repair/replacement is required. No work will be required on this component during R12.

Responsible Dept: WPO Eng Programs Mgmt CA&A

Contact:

Originated: 04/03/2003 by Hartjen,Harry G, WPO Eng Programs Staff Affected Systems: 0109 Affected Equipment: MS-FCV-1154 CR-IP3-2003-01 887 Significance: C - REVIEW & CORRECT Reportability:

Operability: EQUIPMENT INOPERABLE CR Status: Closed on April 29, 2003 Classification Code: NON-SIGNIFICANT

Description:

During a FAC examination (WO IP3-02-23261, 03-PT-10), wall thinning was noted on piping upstream of an orifice block on a HP Turbine steam drain.

The remaining wall thickness is not sufficient to last through R13, and needs to be replaced during R12.

The piping to be replaced is approximately 5 feet of 1" carbon steel, schedule 80 pipe. This replacement is located upstream of the orifice block located on the line from the 32" HP Turbine exhaust. Orifice block is located under the HP Turbine 18' North of the 33 condenser and 5' West of the East edge of the elevation 30' Mezz. Platform; orifice elevation 41'-6".

Scaffold is in place and insulation has been removed.

Page 38of63

"'U Entergy Operations, Inc. Condition Report List m September 29,2008 10:12 AM

()

0 Responsible Dept: WPO Eng Programs Mgmt 0

0 CA&A

Contact:

R Perra Originated: 04/04/2003 by Hartjen,Harry G, WPO Eng Programs Staff

<D I'V Affected Systems: 0108 Affected Equipment:

CJl CJl V>

CR-IP3-2003-01927 Significance: C - REVIEW & CORRECT Reportability:

Operability: EQUIPMENT OPERABLE CR Status: Closed on July 02, 2003 Classification Code: NON-SIGNIFICANT

Description:

During a FAC examination (WO IP3-02-24847, EX-02.9-02P), wall thinning was noted on an elbow on the line from the Moisture Separator 1B to the extraction steam header.

The remaining wall thickness is sufficient to last through R13, per review of calculation IP3-CALC-EX-03444.

No piping repair/replacement is required. No work will be required on this component during R12.

Responsible Dept: WPO Eng Programs Mgmt CA&A

Contact:

Originated: 04/05/2003 by Hartjen,Harry G, WPO Eng Programs Staff Affected Systems: 0109 Affected Equipment:

CR-IP3-2003-02038 Significance: C - REVIEW & CORRECT Reportability:

Operability: EQUIPMENT OPERABLE CR Status: Closed on July 01, 2003 Classification Code: NON-SIGNIFICANT

Description:

During a FAC examination (WO IP3-02-23374, 03-PT-13), wall thinning was noted on piping up and downstream of MS-FCV-1159 ..

The remaining wall thickness is sufficient to last through R 13, per review of calculation IP3-CALC-MS-02515 No piping repair/replacement is required. No work will be required on this component during R12.

Responsible Dept: WPO Eng Programs Mgmt CA&A

Contact:

Originated: 04/07/2003 by Hartjen,Harry G, WPO Eng Programs Staff Affected Systems: 0108 Affected Equipment: MS-FCV-1159 CR-IP3-2003-02242 Significance: C - REVIEW & CORRECT Reportability:

Operability: EQUIPMENT OPERABLE CR Status: Closed on July 02, 2003 Classification Code: NON-SIGNIFICANT

Description:

During a FAC examination (WO 13-010467402, 03-PT-09), wall thinning was noted on piping up and downstream of MS-FCV-1157.

Page 39 of 63

"'U Entergy Operations, Inc. Condition Report List m September 29,2008 10:12 AM

()

0 The remaining wall thickness is sufficient to last through R13, per review of calculation IP3-CALC-MS-03085 0

0

<D No piping repair/replacement is required. No work will be required on this component during R12.

I'V CJl Responsible Dept: WPO Eng Programs Mgmt CJl

.j:::o..

CA&A

Contact:

Originated: 04/11/2003 by Hartjen,Harry G, WPO Eng Programs Staff Affected Systems: Affected Equipment:

CR-IP3-2003-02243 Significance: C- REVIEW & CORRECT Reportability:

Operability: EQUIPMENT OPERABLE CR Status: Closed on June 27, 2003 Classification Code: NON-SIGNIFICANT

Description:

During a FAC examination (WO IP3-02-23339, 03-PT-12), wall thinning was noted on piping up and downstream of MS-FCV-1155.

The remaining wall thickness is sufficient to last through R13, per review of calculation IP3-CALC-MS-03085 No piping repair/replacement is required. No work will be required on this component during R12.

Responsible Dept: WPO Eng Programs Mgmt CA&A

Contact:

Originated: 04/11/2003 by Hartjen,Harry G, WPO Eng Programs Staff Affected Systems: Affected Equipment:

CR-IP3-2003-02250 Significance: C REVIEW & CORRECT Reportability:

Operability: EQUIPMENT OPERABLE CR Status: Closed on April14, 2003 Classification Code: NON-SIGNIFICANT

Description:

During removal of TM l.R-0 1-3-093 under WO# 13-01 0188700, the orifice flanges associated with the Moisture Preseparator 1B Extraction Steam header were found to be misaligned in excess of the allowable cold spring. In addition, the first upstream 90 degree elbow has erosion-corrosion induced wall thinning.

Responsible Dept: Eng P&C Prog & Comp Mgmt CA&A

Contact:

Originated: 04/11/2003 by Bristoi,Charles W, MAINT-Mech Staff Affected Systems: Affected Equipment:

CR-IP3-2003-02319 Significance: C - REVIEW & CORRECT Reportability:

Operability: ADMIN- NA CR Status: Closed on August 15, 2003 Classification Code: NON-SIGNIFICANT

Description:

During a FAC examination, (WO IP3-03-10074, EX-02.2-02T) wall thinning was found on a 10" X 18" tee in the line from the 2A preseparator to the extraction steam header. FAC component EX-02.1-06T on drawing EC-H-50082 is located under the HP Turbine 30' el.

Page 40 of63

"'U Entergy Operations, Inc. Condition Report List September 29, 2008 10:12 AM m

()

0 Responsible Dept: WPO Eng Programs Mgmt 0

0 CA&A

Contact:

R Perra Originated: 04/13/2003 by Hartjen,Harry G, WPO Eng Programs Staff

<D I'V Affected Systems: 0109 Affected Equipment:

CJl CJl CJl CR-JP3-2003-02332 Significance: C- REVIEW & CORRECT Reportability:

Operability: EQUIPMENT OPERABLE CR Status: Closed on July 07, 2003 Classification Code: NON-SIGNIFICANT

Description:

During a FAC examination (WO IP3-02-24686, FW-03.1 C-1 OE), wall thinning was noted on feedwater piping upstream of the Steam Generator 34 inlet nozzle.

The remaining wall thickness is sufficient to last through R13, per calculation IP3-CALC-FW-03807, Rev. 0.

No piping repair/replacement is required. No work will be required on this component during R12.

Responsible Dept: WPO Eng Programs Mgmt CA&A

Contact:

Originated: 04/14/2003 by Hartjen,Harry G, WPO Eng Programs Staff Affected Systems: Affected Equipment:

CR-IP3-2003-02430 Significance: C- REVIEW & CORRECT Reportability:

Operability: EQUIPMENT OPERABLE CR Status: Closed on April 28, 2003 Classification Code: NON-SIGNIFICANT

Description:

During a FAC examination (WO IP3-02-23568, 03-PT-15}, wall thinning was noted on piping immediately upstream of MS-HCV-416-3.

The remaining wall thickness is sufficient to last through R13, per calculation IP3-CALC*-MS-03817.

No piping repair/replacement is required. No work will be required on this component during R12.

Responsible Dept: WPO Eng Programs Mgmt CA&A

Contact:

Originated: 04/16/2003 by Hartjen,Harry G, WPO Eng Programs Staff Affected Systems: 0114 Affected Equipment: MS-HCV-416-3 CR-IP3-2003-02431 Significance: C -REVIEW & CORRECT Reportability:

Operability: EQUIPMENT OPERABLE CR Status: Closed on April 28, 2003 Classification Code: NON-SIGNIFICANT

Description:

During a FAC examination (WO IP3-02-23702, 03-PT-16), wall thinning was noted on piping up and downstream of MS-AOV-1004 and piping upstream of MS-HCV-416-4.

Page 41 of 63

"'U Entergy Operations, Inc. Condition Report List September 29, 2008 10:12 AM m

()

0 The remaining wall thickness is sufficient to last through R13, per calculation IP3-CALC-MS-03817 0

0 No piping repair/replacement is required . No work will be required on this component during R12.

<D I'V CJl Responsible Dept: WPO Eng Programs Mgmt CJl (J) CA&A

Contact:

Originated: 04/16/2003 by Hartjen,Harry G, WPO Eng Programs Staff Affected Systems: 0108,0114 Affected Equipment: MS-AOV-1004, MS-HCV-416-4 CR-IP2-2004-00512 Significance: C- REVIEW & CORRECT Reportability: NOT REPORT ABLE Operability: EQUIPMENT OPERABLE CR Status: Closed on February 18, 2004 Classification Code: NON-SIGNIFICANT

Description:

Wall measurement around the Unit 1 Integrated Liquid Waste Handling (ILWH) System release flow meter (CT-971) are below the minimum allowable. For a 3" schedule 40 pipe, the nominal wall thickness is 0.216". For the area immediately downstream of the orifice 2" away, wall thickness was measured to be 0.098". Other results are as follows:

I was able to get the UT information for you this evening. I took several readings upstream and downstream. I took readings at 0, 90, 180, & 270 at a distance of 2" and 6" from the weld. I also took several readings on the "pump" side of the wall on both painted and non-painted carbon steel pipe. Here are the results in inches:

Location 0 90N 180 270S 6" upstr .173 .156 .155 .168 2" upstr .160 .155 .151 .216 2" dnstr .110 .122 .098 .098 6" dnstr .149 .146 .134 .145 Pump Side .184 - .200 Painted

.200 Not Painted The localized wall thinning is probably attributed to the orifice operation over time. A rough estimate of the remaining wall appears to be adequate. However, Civil Structural Engineering should perform a structural evaluation of the piping system.

This inspection was associated with CR-IP2-2004-001 07 and CR-IP2-2003-05895 investigation. The documented condition impact accuracy of the flow instrumentation.

Responsible Dept: Design Eng Mgmt CA&A

Contact:

Originated: 02/03/2004 by Chan,Tat, System Eng Primary System Staff Affected Systems: ILWH Affected Equipment: CT971-FXE CR-IP2-2004-02954 Significance: C- REVIEW & CORRECT Reportability:

Operability: CR Status: Closed on July 26, 2004 Classification Code: NON-SIGNIFICANT

PagtJ42of63

"'U Entergy Operations, Inc. Condition Report List m September 29,2008 10:12 AM

()

0

Description:

0 0 During Flow Accelerated Corrosion (FAG) examination (WO IP2-03-26606) FAG point 214-25P, wall thinning was noted.

<D I'V No piping repair/replacement is required. No work is required on this component prior to 2R16.

CJl CJl

-.....! This component was previously examined during 2R15.

The remaining wall thickness is sufficient to last through 2R16 per Altran FAG Program Structural Evaluation report.15P-214-25P.

Responsible Dept: P&C Eng Codes Mgmt CA&A

Contact:

Originated: 06/24/2004 by Hartjen,Harry G, P&C Eng Programs Staff Affected Systems: MS Affected Equipment: FAC-214-25P CR-IP2-2004-05358 Significance: C- REVIEW & CORRECT Reportability:

Operability: CR Status: Closed on December 17,2004 Classification Code: NON-SIGNIFICANT

Description:

During UT inspection of component MS-1 B26 (90 ELBOW) in the main steam line wall thinning was detected below the administrative screening criteria of 70% of nominal wall thickness. The nominal thickness and the screening criteria of the component is 0.432 inch and 0.302 inch respectively and the minimum measured wall thickness found was 0.283 inch. Minimum wall calculation IP-CALC-*04-01069 Rev.O evaluated the adverse condition and dispositioned the component as acceptable for continued service requiring a wall thickness of 0.255 inch for two more years of service; this meets all design conditions for this non-safety line. Work tracking item WT-1 P2-2004-00000-CA-00257 was generated to revise the calculation to determine the remaining service life and subsequently the re-inspection interval of the component.

Responsible Dept: P&C Eng Codes Mgmt CA&A

Contact:

Originated: 10/29/2004 by Hartjen,Harry G, P&C Eng Programs Staff Affected Systems: MS Affected Equipment: FAC-MS-1 B26 CR-IP2-2004-05673 Significance: C- REVIEW & CORRECT Reportability:

Operability: CR Status: Closed on December 06, 2004 Classification Code: NON-SIGNIFICANT

Description:

During UT inspection of components LPFW22C-1 N ( IP2-02-52403) and LPFW22C-2N (IP2-02-52414) extraction steam lines to the 22C FW Heater (located inside the condenser), wall thinning was detected.

Minimum wall calculation IP-CALC-04-01620 Rev. 0 evaluated the wall thinning and dispositioned the component as acceptable for continued service through 2R 17.

The nominal thickness and the screening criteria of these components are 0.375 inch and 0.263 inch respectively. The minimum wall thickness for LPFW22C-1 N was 0.125" and LPFW22C-2N was 0.133". Minimum required thickness for these components is 0.075". A work tracking item was generated (WT-IP2-2004-00000-CA-00267) to revise the calculation to determine the remaining service life and recommend repair or replacement during 2R17.

Responsible Dept: P&C Eng Codes Mgmt CA&A

Contact:

Joe Reynolds Originated: 11/04/2004 by Hartjen,Harry G, P&C Eng Codes Staff Affected Systems: MS Affected Equipment: FAC-LPFW22C-1N, FAC-LPFW22C-2N

Page 43of63

"'U Entergy Operations, Inc. Condition Report List m September 29, 2008 10:12 AM

()

0 0 CR-IP2-2004-05840 Significance: C- REVIEW & CORRECT Reportability:

0

<D Operability: CR Status: Closed on November 24, 2004 I'V CJl CJl Classification Code: NON-SIGNIFICANT CX>

Description:

FAG Examination IP2-03-26635 22 Boiler Feed pump Turbine Exhaust Casing.

During the FAG UT examination of the 22 BFP Turbine exhaust casing, wall thinning was detected.

Regarding the minimum wall thickness required for the casing , Siemens Engineering has stated in a November 1, 2004 e-mail "The plate thickness is supposed to be 5/8" .625" half of the plate thickness is 5/16"=.3125". Our Engineering says you can go to half plate thickness before corrective action has to be taken."

The lowest reading on the turbine casing is 0.277", which is below the criteria of 0.3125" where corrective action has to be taken.

Need resolution if the as found wall thickness is acceptable for continued service or rElpair is needed.

Need resolution before mode 4 Responsible Dept: P&C Eng Codes Mgmt CA&A

Contact:

Originated: 11/08/2004 by Hartjen,Harry G, P&C Eng Codes Staff Affected Systems: MS Affected Equipment: 22BFPT CR-IP2-2004-05953 Significance: D- ADMIN CLOSURE Reportability:

Operability: CR Status: Closed on November 12, 2004 Classification Code: NON-SIGNIFICANT

Description:

During UT inspection of component MST-24 (IP2-03-26634) wall thinning was detected below the administrative screening criteria of 70% of nominal wall thickness. This was not unexpected as this component was inspected during 2R15.

This component is acceptable for continued service past 2R17.

The minimum required thickness for two more years of service is 0.067" per calculation IP-CALC-04-00763, Rev. 0. The minimum thickness found on the inspection is 0.081 ".

Work tracking item WT-IP2-2004-00000-CA-00270 was generated to revise the calculation to determine the remaining service life andre-inspection interval for this component.

Responsible Dept: P&C Eng Codes Mgmt CA&A

Contact:

Originated: 11/10/2004 by Hartjen,Harry G, P&C Eng Codes Staff Affected Systems: MS Affected Equipment: FAC-MST-24

44 of 63

"'U Entergy Operations, Inc. Condition Report List m September29, 200810:12 AM

()

0 0 CR-IP2-2004-06776 Significance: D- ADMIN CLOSURE Reportability: NOT REPORT ABLE 0

<D Operability: OPERABLE JUDGEMENT CR Status: Closed on December 28, 2004 I'V CJl Classification Code: NON-SIGNIPICANT CJl

<D

Description:

The preliminary UT reports for the 9 welds upstream of valve SWN-62-6 on the 1-2-3 header of the 23 EDG has inidcations below the minimum wall calculated.

The 5th, 6th, and 7th welds upstream of valve SWN-62-6 have areas below the min wall value of .071 inches but the flaw lengths meet the code case 513 allowable flaw lengths for operability. This is in accordance with calculation IP-CALC-04-1760. All of the welds on the line show some levels of wall thinning and will need to be addressed but the line is operable at this time.

Responsible Dept: System Eng Secondary System Mgmt CA&A

Contact:

Originated: 12/21/2004 by Drake,Richard S, Design Eng Civii/Str Staff Affected Systems: SW Affected Equipment:

CR-IP3-2005-00117 Significance: C REVIEW & CORRECT Reportability:

Operability: EQUIPMENT OPERABLE CR Status: Closed on February 15, 2005 Classification Code: NON-SIGNIFICANT

Description:

During 3R13P FAC UT inspection of High Pressure Turbine Drain (HPTD) piping, FAC inspection point FAC-05-TD-03, (WO IP3-03-24803, UT report 05UT002), wall th1nnmg was detected on a ?" socket weld elbow and ?" downstream pipe (- 6" long, immediately upstream of an orifice block on the piping downstream of valve MS-FCV-1158).

These components are acceptable for continued service past 3R13.

The minimum required thickness for two more years of service is 0.059" per calculation IP-CALC-04-01795. The minimum thickness found on this inspection was 0.059" on the elbow.

Based on the calculation, although there is sufficient remaining service life for these components past 3R13, there is not enough remaining service life to reach 3R14. Therefore these components must be replaced during 3R13.

EOC:

This was are-inspection of these two components. This line was previously inspected during 3R11 and only these components required re-inspection during 3R13P. HPTD oioina is included in the FAC Program and several FAC inspections of HPTD piping were performed in past outages and more are to be performed during 3R13.

Responsible Dept: P&C Eng Codes Mgmt CA&A

Contact:

Originated: 01/13/2005 by Hartjen,Harry G, P&C Eng Codes Staff Affected Systems: Affected Equipment:

CR-IP3-2005-00276 Significance: C - REVIEW & CORRECT Reportability: NOT REPORT ABLE Operability: NOT REQUIRED CR Status: Closed on February 22, 2005 Classification Code: NON-SIGNIFICANT

Description:

Page 45 of63

"'U Entergy Operations, Inc. Condition Report List m September 29, 2008 10:12 AM

()

0 During UT inspection of component 05-HD-03 (IP3-03-24820) wall thinning was detected below the administrative screening criteria of 70% of nominal wall thickness (0.175").

0 0

<D The minimum required thickness for two more years of service is 0.108" per calculation IP-CALC-04-01787, Rev. 0. The minimum thickness found by this inspection is 0.169" I'V CJl Responsible Dept: P&C Eng Codes Mgmt (J) 0 CA&A

Contact:

Originated: 01/25/2005 by Allen,Robert E, P&C Programs Staff Affected Systems: HD Affected Equipment: FAC-05-HD-03 CR-IP2-2005-00551 Significance: C - REVIEW & CORRECT Reportability: NOT REPORTABLE Operability: EQUIPMENT INOPERABLE CR Status: Closed on July 15, 2005 Classification Code: NON-SIGNIFICANT

Description:

NDE was performed to characterize the through wall piping leak on 3" Line# 818, U/S of MS-643, and revealed the presence of two cracks. These cracks are from the support attachment welds onto the pipe; 1" long- from the bottom of the South attachment weld, and 1/4" long- from the bottom of the North attachment weld. The South crack was seen leaking under pressure. No pipe wall thinning was revealed by the NDE performed.

Responsible Dept: Design Eng Mgmt CA&A

Contact:

Originated: 02/08/2005 by Allen,Robert E, P&C Eng Programs Staff Affected Systems: MS Affected Equipment: 3" LINE# 818 CR-IP3-2005-00613 Significance: D- ADMIN CLOSURE Reportability:

Operability: NOT REQUIRED CR Status: Closed on February 22, 2005 Classification Code: NON-SIGNIFICANT

Description:

During 3R13P FAC UT inspection of the 10" X 14" expander downstream of valve 5HD-LCV-1127B, (Heater Drain Tank Bypass to Condenser 33 LCV), wall thinning was detected below the administrative screening criteria of 70% of the nominal wall thickness (0.175"). The FAC exam was FAC-05-HD-02, WO IP3-03-24819, UT report 05UT014.

This component is acceptable for continued service.

The minimum required thickness for two more years of continuous service per calculation IP-CALC-04-01787 is 0.1 08". The minimum thickness found by this inspection was 0.168".

EOC:

This component is included in the FAC Program and tracked in the IP3 Flow Accelerated Corrosion Small-Bore and Augmented Monitoring Program IP3-RPT-MUL T-03162. Similar locations were inspected during past outages and 3R13P, including downstream of valves 5HD-LCV-1127D (IP3-02-23587), (IP3-03-24817), and 5HD-LCV-1127C (IP3-03-24820).

These components are also monitored by the FAC Program. Comparable components have been inspected and are monitored in the Unit 2 FAC Program.

Responsible Dept: P&C Eng Codes Mgmt CA&A

Contact:

Originated: 02/15/2005 by Hartjen,Harry G, P&C Eng Codes Staff Affected Systems: HD Affected Equipment:

Page 46of63

"'U Entergy Operations, Inc. Condition Report List m September 29, 2008 10:12 AM

()

0 0 CR-IP3-2005-01122 Significance: C - REVIEW & CORRECT Reportability:

0

<D Operability: CR Status: Closed on March 28, 2005 I'V CJl (J) Classification Code: NON-SIGNIFICANT

Description:

  • ----------------------*-----------------------------------------------------------------------------------------------------~

During initial errosion/corrosion inspections of MSR 31A,32A,32B,33A,33B various issues were discovered as follows:

1. All 5 noted MSRs are missing horizontal perforated plates which limits steam flow at the U-Bend end cap,
2. MSRs 31A, 32A, 33A have wall thinning, and several holes at the outer shell of the U-bend,
3. All 5 MSRs have several areas of surface wear which may require weld repairs. These inspected areas have been documented in a preliminary report by Design Engineering.

2.

Responsible Dept: Eng Project Mgmt CA&A

Contact:

Originated: 03/15/2005 by lraola,Antonio J, Eng Power Uprate Staff Affected Systems: RS Affected Equipment:

CR-IP3-2005-01149 Significance: C REVIEW & CORRECT Reportability: NOT REPORTABLE Operability: NOT REQUIRED CR Status: Closed on March 22, 2005 Classification Code: NON-SIGNIFICANT

Description:

During High Pressure Turbine Drain (HPTD) FAC inspection IP3-05-13301, FAC location FAC-05-TD-06, wall thinning was detected on a 2 inch diameter pipe at the condenser wall, downstream of MS-FCV-1158.

The minimum measured wall thickness found was 0.085" which is not a sufficient thickness to last until 3R14, based on a review of calculation IP-CALC-04-01795.

EOC:

This is a reinspection of this component and wall thinning was expected.. This component was inspected previously during 3R12 as 03-PT-11, IP3-02-23328. HPTD piping is included in the FAC program and several FAC inspections of HPTD piping were performed in past outages and during 3R13.

Responsible Dept: Design Eng Mgmt CA&A

Contact:

Originated: 03/16/2005 by Hartjen,Harry G, P&C Eng Codes Staff Affected Systems: MS Affected Equipment: MS-FCV-1158 CR-IP3-2005-01201 Significance: C - REVIEW & CORRECT Reportability:

Operability: NOT REQUIRED CR Status: Closed on May 26, 2005 Classification Code: NON-SIGNIFICANT

Description:

During FAC inspection IP3-03-24865, FAC-05-GS-01, Low Pressure Turbine Gland Sealing Steam Supply Drain Line, wall thinning was detected below the administrative screening criteria of 70% of nominal wall thickness.

This component is acceptable for continued service past 3R14.

Page 47 of 63

"'U Entergy Operations, Inc. Condition Report List m September 29, 2008 10:12 AM

()

0 The minimum required thickness for two more years of service is 0.1 07" per calculation IP-CALC-05-00051, Rev. 0. The minimum thickness found on this FAC inspection was 0.189" 0 on the second 90 degree elbow upstream of the condenser.

0

<D I'V Responsible Dept: P&C Eng Codes Mgmt CJl (J) CA&A

Contact:

Originated: 03/17/2005 by Hartjen,Harry G, P&C Eng Codes Staff I'V Affected Systems: MS Affected Equipment:

CR-IP3-2005-01446 Significance: C - REVIEW & CORRECT Reportability: NOT REPORT ABLE Operability: NOT REQUIRED CR Status: Closed on April 03, 2005 Classification Code: NON-SIGNIFICANT

Description:

During FAC inspection IP3-03-24 791, FAC location FAC-05-VCD-08, wall thinning was detected on a 3 inch elbow downstream of valve VCD-PCV-7008 and upstream of valve VCD-18.

The minimum wall thickness found during this exam was 0.052 inches which is below the minimum required thickness of 0.123 inches per calculation IP-CALC-05-00017, Rev. 0. The remaining wall thickness is not sufficient to last until 3R14 and this elbow must be replaced during 3R13.

Responsible Dept: P&C Eng Codes Mgmt CA&A

Contact:

Originated: 03/23/2005 by Hartjen,Harry G, P&C Eng Codes Staff Affected Systems: RS Affected Equipment: VCD-PCV-7008 CR-IP3-2005-01490 Significance: C - REVIEW & CORRECT Reportability: NOT REPORT ABLE Operability: NOT REQUIRED CR Status: Closed on April 03, 2005 Classification Code: NON-SIGNIFICANT

Description:

During condensate system FAC inspection, IP3-04-13369, FAC location CD-05.4-03T, wall thinning was detected on a 24" branch of a 30" tee on the 35 heater header to the BFP suctions.

Ths minimum measured wall thickness found was 0.654" which is not a sufficient thickness to last until 3R14, based on a review of calculation IP-CALC-05-00052, Rev. 0.

Calculation IP-CALC-05-00052 requires a minimum thickness of 0.660" for 2 more years of operation.

EOC:

This is a reinspection of this component and thinning was expected. This component was inspected during 3R12 IP3-03-10463 Responsible Dept: P&C Eng Programs Mgmt CA&A

Contact:

Originated: 03/24/2005 by Hartjen,Harry G, P&C Eng Codes Staff Affected Systems: MFW Affected Equipment: MBFP SUCTION PIPE

Page 48of63

"'U Entergy Operations, Inc. Condition Report List m September 29, 2008 10:12 AM

()

0 0 CR-IP3-2005-01685 Significance: C REVIEW & CORRECT Reportability: NOT REPORTABLE 0

<D Operability: EQUIPMENT OPERABLE CR Status: Closed on May 26, 2005 I'V CJl (J) Classification Code: NON-SIGNIFICANT V>

Description:

During FAC inspection IP3-03-24849, FAC MST-04, Main Steam Trap 52, wall thinning was detected below the administrative screening criteria of 70% of nominal wall thickness.

The component is acceptable for continued service.past 3R14.

The minimum required thickness for two more years of service is 0.068" per calculation IP-CALC-05-00099, Rev. 0. The minimum thickness fouund on this FAC inspection was 0 . 118".

Responsible Dept: P&C Eng Codes Mgmt CA&A

Contact:

Originated: 03/29/2005 by Hartjen,Harry G, P&C Eng Codes Staff Affected Systems: MS Affected Equipment:

CR-IP3-2005-01691 Significance: C - REVIEW & CORRECT Reportability: NOT REPORTABLE Operability: NOT REQUIRED CR Status: Closed on May 26, 2005 Classification Code: NON-SIGNIFICANT

Description:

During FAC inspection IP3-03-24812, FAC-05-EX-01, Northeast Crossunder 31 B Drip Pot Drain, wall thinning was detected below the administrative screening criteria of 70% of nominal wall thickness.

The component is acceptable for continued service.past 3R14.

The minimum required thickness for two more years of service is 0.059" per calculation IP-CALC-04-01786, Rev. 0. The minimum thickness fouund on this FAC inspection was 0.097".

Responsible Dept: P&C Eng Codes Mgmt CA&A

Contact:

Originated: 03/29/2005 by Hartjen,Harry G, P&C Eng Codes Staff Affected Systems: EX Affected Equipment:

CR-IP3-2005-01699 Significance: C - REVIEW & CORRECT Reportability: NOT REPORTABLE Operability: NOT REQUIRED CR Status: Closed on May 26, 2005 Classification Code: NON-SIGNIFICANT

Description:

Page 49of63

"'U Entergy Operations, Inc. Condition Report List m September 29, 2008 10:12 AM

()

0 During FAC inspection IP3-05-14125, EX-05.2B-06N, LP Turbine extraction steam to 32B feedwater heater, wall thinning was detected below the administrative screening criteria of 0

0 70% of nominal wall thickness.

<D I'V The component is acceptable for continued service past 3R14.

CJl (J)

.j:::o..

The minimum required thickness for two more years of operation is 0.109" per calculation IP-CALC-04-01786, Rev. 0. The minimum measured thickness found was 0.236".

Responsible Dept: P&C Eng Codes Mgmt CA&A

Contact:

Originated: 03/29/2005 by Hartjen,Harry G, P&C Eng Codes Staff Affected Systems: EX Affected Equipment:

CR-IP3-2005-01727 Significance: C - REVIEW & CORRECT Reportability: NOT REPORT ABLE Operability: EQUIPMENT OPERABLE CR Status: Closed on May 26, 2005 Classification Code: NON-SIGNIFICANT

Description:

During FAC inspection of Main Steam Trap discharge piping, IP3-03-24839, FAC-05-MST-01, wall thinning was detected on a 1 inch diameter pipe downstream of valve MS-101-14.

This component is acceptable for continued service past 3R14.

The minimum measured wall thickness found was 0.077" The minimum required thickness for two more years of operation is 0.068" per calculation IP-CALC-05-00099, Rev. 0.

EOC:

Main Steam Trap piping is included in the FAC program and several FAC inspections of Main Steam Trap piping were performed in past outages and 3R13. Any liiiiiiiiii!:J found is monitored and tracked in the FAC Program.

Responsible Dept: P&C Eng Codes Mgmt CA&A

Contact:

Originated: 03/30/2005 by Hartjen,Harry G, P&C Eng Codes Staff Affected Systems: HPSD, MS Affected Equipment: MS-101-14 CR-IP3-2005-01745 Significance: C- REVIEW & CORRECT Reportability: NOT REPORT ABLE Operability: NOT REQUIRED CR Status: Closed on May 26, 2005 Classification Code: NON-SIGNIFICANT

Description:

During FAC inspection IP3-03-24804, FAC-05-TD-04, 2" piping downstream of MS-FCV-1154, wall thinning was detected below the administrative screening criteria of 70% of nominal wall thickness.

This component is acceptable for continued service past 3R14.

The minimum required thickness for 2 more years of service is 0.099" per calculation IP-CALC-04-01795, Rev. 0. The minimum thickness found on this FAC inspection was 0.148".

(70% of nominal thickness is 0.153")

Responsible Dept: P&C Eng Codes Mgmt

Page 50of63

"'U Entergy Operations, Inc. Condition Report List September 29, 2008 10:12 AM m

()

0 CA&A

Contact:

Originated: 03/30/2005 by Hartjen,Harry G, P&C Eng Codes Staff 0

0 Affected Systems: MS Affected Equipment:

<D I'V CJl (J) CR-IP3-2005-03506 Significance: C- REVIEW & CORRECT Reportability:

CJl Operability: CR Status: Closed on July 14, 2005 Classification Code: NON-SIGNIFICANT

Description:

Alert PM has information unrelated to job within package. Work Order IP3-04-19225 is for the 1Y LUBRICATION OF FAN-312-AB lAW 0-LUB-401-GEN (PTO & SCAFFOLD. WORK WITH FAN PM). Under the Ops Impact Summary section, the following was found; "SUPPORT & PERFORM RADIOGRAPHIC WALL THICKNESS EXAMINATION OF PIPING WELD IN SERVICE WATER SYSTEM; RESTORE WALL THICKNESS VIA WELDING IF EXAMINATION RESULTS REVEAL WALL THINNING BEYOND ACCEPTANCE CRITERIA." It is obvious that this has nothing to do with the fan that is being lubricated under this work order, however it is another example of an Alert PM which is auto generated which goes unchecked until it gets to Work Control for protection review. This is another setup for failure.

Responsible Dept: PS&O Planning Mgmt CA&A

Contact:

Originated: 07/07/2005 by Odendahi,Brian J, PS&O Work Control Staff Affected Systems: Affected Equipment:

CR-IP2-2006-02549 Significance: C -REVIEW & CORRECT Reportability:

Operability: CR Stat.us: Closed on May 25, 2006 Classification Code: NON-SIGNIFICANT

Description:

During FAC inspection IP2-05-17617. MST-48, Main Steam Trap discharge, wall thinning was detected below that necessary for 2 more years of service and will Jire replacement during 2R17.

The component requiring replacement is the 1"diameter pipe (approximately 2" long) immediately upstream of MS-101-57, MST-48 Outlet check valve.

The minimum required thickness for two more years of service is 0.072" per calculation IP-CALC-06-00100. The minimum thickness found on this component was 0.063". Calculated remaining service life past 2R 17 is 1.6 years.

Responsible Dept: P&C Eng Codes Mgmt CA&A

Contact:

Originated: 05/03/2006 by Hartjen,Harry G, P&C Eng Codes Staff Affected Systems: MS Affected Equipment: MST-48 CR-IP2-2006-02382 Significance: C REVIEW & CORRECT Reportability:

Operability: NOT REQUIRED CR Status: Closed on April30, 2006 Classification Code: NON-SIGNIFICANT

Description:

As part of the implementation of ER-04-2-047 (work order IP2-05-15502) craft removed

Page 51 of 63

"'U Entergy Operations, Inc. Condition Report List m September 29, 2008 10:12 AM

()

0 Both 22" 2EX inlet pipes from the 22CLPH feedwater heater (LINE EX/LPFW 22C-1 N 0 And LINE EX/LPFW 22C-2N inside 21 COND). Inside both 22CLPH inlet nozzles there were indications of pipe wall thinning. "Tiger Striping" was observed in both inlet nozzles, 0

<D FAC-LPFW22C-1 N and FAC-LPFW22C-2N.

I'V CJl Responsible Dept: System Eng Secondary System Mgmt (J)

(J)

CA&A

Contact:

Joe Reynolds Originated: 04/29/2006 by Norris,David, MAINT-Support Staff Affected Systems: MS Affected Equipment: 22CLPH, FAC-LPFW22C-1 N CR-IP2-2006-02632 Significance: C- REVIEW & CORRECT Reportability:

Operability: CR Status: Closed on May 10, 2006 Classification Code: NON-SIGNIFICANT

Description:

Great catch by iTi eddy current inspection team. During eddy current inspection of the 21A condenser tube bundle they identified some titanium tubes with unusually accelerated wall thining at one particular location. They entered the condenser to look at the steamside of the tubes and find reason for wall thinning. They found an MSR drain/blowdown line on the south east corner of the condenser with part of the pipe wall blown out allowing steam impingment on the condenser tubes.

Responsible Dept: System Eng Secondary System Mgmt CA&A

Contact:

Originated: 05/04/2006 by Mosher,George, System Eng Secondary System Staff Affected Systems: Affected Equipment:

CR-IP3-2006-02122 Significance: C - REVIEW & CORRECT Reportability:

Operability: NOT REQUIRED CR Status: Closed on September 28, 2006 Classification Code: NON-SIGNIFICANT

Description:

During FAC inspection of the 32A MSR Vent Chamber Drain line to the condenser, IP3-06-15699, a localized thinned wall area in an elbow extradose was detHcted that was below the thickness required by calculation.

The minimum measured wall thickness found was 0.055", UT Report 06UT167. The minimum thickness required by calculation is 0.141" A calculation is needed on this localized worn area to determine if the remaining service life of this elbow can be extended until 3R 14.

This wall thinning is similar to the wall thinning found on 33A MSR VCD line to the condenser, (CR-IP3-2006-01893; 06/21/2006).

Responsible Dept: P&C Eng Codes Mgmt CA&A

Contact:

Originated: 07111/2006 by Hartjen,Harry G, P&C Eng Codes Staff Affected Systems: HD Affected Equipment:

CR-IP2-2006-02685 Significance: C REVIEW & CORRECT Reportability:

Operability: CR Status: Closed on July 12, 2006 Classification Code: NON-SIGNIFICANT

Description:

Page 52of63

"'U Entergy Operations, Inc. Condition Report List m September 29, 2008 10:12 AM

()

0 During FAG inspection of Extraction Steam piping to the 22A Feedwater Heater, IP-02-52336, LPFW22A-1 N, wall thinning was detected below that is necessary for 2 more years of 0

0 operation.

<D I'V CJl The minimum measured wall thickness found was 0.084", UT report 06UT121. The minimum required thicknesss for 2 more years of operationis 0.112" per calculation (J) IP-CALC-06-00100, Rev. 0.

As this thinned area is localized, a calculation is needed on this area to determine if the remaining service life of this pipe can be extended past 2R18 or a repair will be required during 2R17.

EOC:

Extraction Steam piping to the 22 Feedwater Heaters is included in the FAG program and all this piping has been inspected. Extraction steam piping to the 22C Feedawter Heater is being replaced in 2R17 and piping to the 22A and 22B Feedwater Heaters is being inspected in 2R17. Any pipe thinning found is monitored and tracked in the FAG Program.

Responsible Dept: P&C Eng Codes Mgmt CA&A

Contact:

Originated: 05/05/2006 by Hartjen,Harry G, P&C Eng Codes Staff Affected Systems: Affected Equipment:

CR-IP2-2006-02621 Significance: C - REVIEW & CORRECT Reportability:

Operability: CR Status: Closed on July 18, 2006 Classification Code: NON-SIGNIFICANT

Description:

During FAG inspection of Extraction Steam piping to the 22B Feedwater Heater, IP2-05-15671, LPFW22B-1N, wall thinning was detected below that was necessary for 2 more years of operation on one localized area of this 22" diameter pipe.

The minimum measured wall thickness found was 0.099" UT Report 06UT1 04. The minimum required thickness for two more years of operation is 0.112" per calculation IP-CALC-06-00100, Rev. 0.

As this thinned area is localized, another calculation will be performed on the actual thinned section of the pipe, potentially extending the remaining service life of this component past 2R18.

EOC:

Extraction Steam piping to the 22 Feedwater Heaters is included in the FAG program and all of this piping has been inspected. Extraction Steam piping to the 22C Feedwater Heater is being replaced in 2R17 and piping to the 22A and 22B Feedwater heaters is being inspected in 2R17. Any pipe thinning found is monitored and tracked in the FAG Program.

Responsible Dept: P&C Eng Codes Mgmt CA&A

Contact:

Originated: 05/04/2006 by Hartjen,Harry G, P&C Eng Codes Statf Affected Systems: Affected Equipment: FAC-LPFW22B-1 N CR-IP2-2006-02277 Significance: C -REVIEW & CORRECT Reportability:

Operability: CR Status: Closed on September 22, 2006 Classification Code: NON-SIGNIFICANT

Description:

Page 53of63

"'U Entergy Operations, Inc. Condition Report List m September 29,2008 10:12 AM

()

0 During FAC inspection of Extraction Steam Trap discharge piping, IP2-05-15900, EST-8, wall thinning was detected on a 3/4 inch diameter pipe downstream of valve 4EX-31-3.

0 0

<D This component is acceptable for continued service past 2R18.

I'V CJl (J) The minimum measured wall thickness found was 0.072" UT Report 06UT059. The minimum required thickness for two more years of operation is 0.034" per calculation CX> IP-CALC-06-00100, Rev. 0.

EOC:

Extraction Steam Trap piping is included in the FAC program and several FAC inspections of Extraction Steam Trap piping were performed in past outages and during 2R17. Any pipe thinning found is monitored and tracked in the FAC Program.

Responsible Dept: P&C Eng Codes Mgmt CA&A

Contact:

Originated: 04/27/2006 by Hartjen,Harry G, P&C Eng Codes Staff Affected Systems: Affected Equipment:

CR-IP2-2006-02689 Significance: C - REVIEW & CORRECT Reportability:

Operability: CR Status: Closed on September 22, 2006 Classification Code: NON-SIGNIFICANT

Description:

During FAC inspection of the Extraction Steam piping to the low pressure Feedwater Heater 228 IP2-05-15672, LPFW228-2N, wall thinning was detected on this 22 inch diameter pipe.

Wall thinning of 70 percent of the nominal wall thickness is documented in a CR.

This component is acceptable for continued srevice past 2R18.

The minimum measured wall thickness found was 0.132" The minimum required thickness for 2 more years of service is 0.112" per calculation IP-CALC-06-00100, Rev. 0.

EOC:

The Extraction Steam piping to the 22 Feedwater Heaters is included in the FAC Program, and all of this piping has been inspected. Extraction Steam piping to the 22C Feedwater Heater is being replaced in 2R17 and piping to the 22A and 228 Feedwater Heaters is being inspected in 2R17. Any pipe wall thinning is being tracked in the FAC Program.

Responsible Dept: P&C Eng Codes Mgmt CA&A

Contact:

Originated: 05/05/2006 by Hartjen,Harry G, P&C Eng Codes Staff Affected Systems: Affected Equipment:

CR-JP3-2007-01550 Significance: C REVIEW & CORRECT Reportability:

Operability: NOT REQUIRED CR Status: Closed on April 04, 2007 Classification Code: NON-SIGNIFICANT

Description:

During FAC inspection IP3-07-16920, component EX-02.14-08E was inspected and wall thinning was found Minimum wall thickness found was 0.192" which is below the minimum required thickness for 2 more years of operation. The worn elbow is located upstream of valve 5EX-1, and shown on drawing EC-H-50001 Responsible Dept: P&C Eng Codes Mgmt

Page 54 of 63

"'U Entergy Operations, Inc. Condition Report List m September 29, 2008 10:12 AM

()

0 CA&A

Contact:

Originated: 03/24/2007 by Hartjen,Harry G, P&C Eng Codes Staff 0 Affected Systems: EX 0 Affected Equipment: 5EX-1

<D I'V CJl (J) CR-IP2-2006-02861 Significance: C- REVIEW & CORRECT Reportability:

<D Operability: CR Status: Closed on September 22, 2006 Classification Code: NON-SIGNIFICANT

Description:

During FAC inspection of the Extraction Stearn piping to the low pressure Feedwater Heater 21A, IP2-02-52328, LPFW21A-3N, wall thinning was detected on this 26 inch diameter pipe.

This component is acceptable for continued service past 2R18.

A CR is generated when wall thinning is found that results in a thickness less than 70% of the nominal pipe thickness. (70% of the nominal wall thickness of this pipe is 0 .262")

Minimum measured thickness for this exam is 0.230", UT report 06UT118.

Minimum required thickness for 2 more years of operation is 0.112" per calculation IP-CALC-06-001 00.

EOC:

Extraction steam piping to the 21 Feedwater Heaters is included in the FAC Program, and other 21 Feedwater Heater extraction lines are being inspected in 2R17. Any pipe wall thinning found is tracked in the FAC Program.

Responsible Dept: P&C Eng Codes Mgmt CA&A

Contact:

Originated: 05/09/2006 by Hartjen,Harry G, P&C Eng Codes Staff Affected Systems: Affected Equipment:

CR-IP2-2006-02625 Significance: C - REVIEW & CORRECT Reportability:

Operability: CR Status: Closed on September 22, 2006 Classification Code: NON-SIGNIFICANT

Description:

During FAC inspection of the Extraction Steam piping to the low pressure Feedwater Heater 22A, IP2-02-52351, LPFW22A-2N, wall thinning was detected on this 22 inch diameter pipe. Wall thinning of 70 percent of the nominal wall thickness is documented in a CR.

This component is acceptable for continued service past 2R18.

The minimum measured wall thickness found was 0.179" UT Report 06UT113. The minimum required thickness for two more years of operation is 0.112" per calculation IP-CALC-06-00100, Rev. 0.

EOC:

Extraction steam piping to the 22 Feedwater Heaters is included in the FAC Program, and all this piping has been inspected. Extraction steam piping to the 22C Feedwater Heater is being replaced in 2R17 and piping to the 22A and 22B Feedwater Heaters is being inspected in 2R17. Any pipe wall thinning found is tracked in the FAC Program.

Responsible Dept: P&C Eng Codes Mgmt

Page 55of63

"'U Entergy Operations, Inc. Condition Report List m September 29,2008 10:12 AM

()

0 CA&A

Contact:

Originated: 05/04/2006 by Hartjen,Harry G, P&C Eng Codes Staff 0

0 Affected Systems: Affected Equipment: LPFW22A-2N

<D I'V CJl

-.....! CR-IP2-2006-02859 Significance: C - REVIEW & CORRECT Reportability:

0 Operability: CR Status: Closed on September 22, 2006 Classification Code: NON-SIGNIFICANT

Description:

During FAG inspection of the Extraction Stearn piping to the low pressure Feedwater Heater 21 A, IP2-02-52316, LPFW21 A-1 N, wall thinning was detected on this 26 inch diameter pipe.

This component is acceptable for continued service past 2R18.

A CR is generated when wall thinning is found that results in a thickness less than 70cYo of the nominal pipe thickness. (70% of the nominal wall thickness of this is 0.262")

Minimum measured thickness for this exam is 0.230", UT report 06UT119.

Minimum required thickness for 2 more years of operation is 0.112" per calculation IP-CALC-06-001 00.

EOC:

Extraction steam piping to the 21 Feedwater Heaters is included in the FAG Program, and other 21 Feedwater Heater extraction lines are being inspected in 2R17. Any PiPe wall thinning found is tracked in the FAG Program.

Responsible Dept: P&C Eng Codes Mgmt CA&A

Contact:

Originated: 05/09/2006 by Hartjen,Harry G, P&C Eng Codes Staff Affected Systems: Affected Equipment:

CR-IP2-2006-02863 Significance: C- REVIEW & CORRECT Reportability:

Operability: NOT REQUIRED CR Status: Closed on September 22, 2006 Classification Code: NON-SIGNIFICANT

Description:

During FAG inspection of the Extraction Steam piping to the low pressure Feedwater Heater 21A, IP2-02-52332, LPFW21A-4N, wall thinning was detected on this 26 inch diameter pipe.

This component is acceptable for continued service past 2R18.

A CR is generated when wall thinning is found that results in a thickness less than 70% of the nominal pipe thickness. (70% of the nominal wall thickness of this pipe is 0.262")

Minimum measured thickness for this exam is 0.236", UT report 06UT120.

Minimum required thickness for 2 more years of operation is 0.112" per calculation IP**CALC-06-001 00.

EOC:

Extraction steam piping to the 21 Feedwater Heaters is included in the FAG Program, and other 21 Feedwater Heater extraction lines are being inspected in 2R17. Any pipe wall thinning found is tracked in the FAG Program.

Responsible Dept: P&C Eng Codes Mgmt

Page 56of63

"'U Entergy Operations, Inc. Condition Report List m September 29, 2008 10:12 AM

()

0 CA&A

Contact:

Originated: 05/09/2006 by Hartjen,Harry G, P&C Eng Codes Staff 0

0 Affected Systems: Affected Equipment:

<D I'V CJl CR-IP3-2006-01893 Significance: C - REVIEW & CORRECT Reportability: NOT REPORT ABLE Operability: ADMIN - NA CR Status: Closed on October 04, 2006 Classification Code: NON-SIGNIFICANT

Description:

During FAC inspection of the 33A MSR Vent Chamber Drain line to the condenser, IP3-06-15700, a localized wall thinned area in an elbow extradose was detected below the thickness required by code calculation.

The minimum measured wall thickness found was 0.112", UT report 06UT158. The minimum thickness required by code calculation is 0.141 ".

A calculation is needed on this localized worn area to determine if the remaining service life of this elbow can be extended until 3R14.

In addition, wall thinning was found on the upstream pipe below 70% of the nominal pipe thickness (0.216"). The minimum measured wall thickness found was 0.135", UT report 06UT157. The minimum thickness required by code calculation is 0.123". A calculation is needed to determine if the remaining service life of this pipe is sufficient for continued operation until 3R14.

Responsible Dept: P&C Eng Codes Mgmt CA&A

Contact:

Originated: 06/21/2006 by Hartjen,Harry G, P&C Eng Codes Staff Affected Systems: HD Affected Equipment:

CR-IP3-2006-03903 Significance: C - REVIEW & CORRECT Reportability:

Operability: NOT REQUIRED CR Status: Closed on December 27, 2006 Classification Code: NON-SIGNIFICANT

Description:

90 day follow up UT exam performed on the leak previously identified on the first weld D/S of valve SWN-34-2 has revealed that wall thinning being monitored in a second area of the weld is now less than the wall thickness allowed by IP-CALC-06-00113.

Responsible Dept: P&C Eng Programs Mgmt CA&A

Contact:

Joe Reynolds Originated: 12/12/2006 by Allen II,Robert E, P&C Eng Codes Staff Affected Systems: SWS Affected Equipment: 18" LINE# 407, SWN-34-2 CR-IP3-2007-01182 Significance: D- ADMIN CLOSURE Reportability:

Operability: CR Status: Closed on March 14, 2007 Classification Code: NON-SIGNIFICANT

Description:

During FAC inspection IP3-06-23447, component RHD-02.14B-02E, wall thinning was found on a reheater drain system 6" diameter elbow.

Page 57 of 63

"'U Entergy Operations, Inc. Condition Report List m September 29,2008 10:12 AM

()

0 0 Minimum wall thickness found was 0.146". The minimum required thickness for continued operation is 0.233". The worn area is concentrated on the elbow extradose for its entirEl 0

<D length. Nominal wall thickness for this pipe is 0.432".

I'V CJl

-.....! The worn elbow is located immediately downstream of the 10" x 6" tee upstream of 36C FWH (RHO B Train).

I'V Responsible Dept: MAINT-Support Mgmt CA&A

Contact:

Joe Reynolds Originated: 03/14/2007 by Hartjen,Harry G, P&C Eng Codes Staff Affected Systems: HD Affected Equipment: HD CR-IP3-2007-01261 Significance: C REVIEW & CORRECT Reportability:

Operability: NOT REQUIRED CR Status: Closed on March 29, 2007 Classification Code: NON-SIGNIFICANT

Description:

Condition: Significant pipe wall thinning detected while performing FAC exam on CHECWORKS component HD-05.1 C-02R (expander downstream of valve 4HD-LCV-1117) under WO IP3-05-24892.

Discussion: Significant wall thinning is defined as a thickness less than 60% of pipe nominal wall thickness. Nominal pipe thickness for this component is 0.280 inches. Minimum measured thickness is 0.127 inches. This equates to 45.35% nominal wall remaining. This component has been evaluated as acceptable for continued service through the next refuel cycle.

Responsible Dept: P&C Eng Codes Mgmt CA&A

Contact:

Originated: 03/16/2007 by Gerber,David S, P&C Eng Codes Staff Affected Systems: l-ID Affected Equipment: HD CR-IP3-2007-00981 Significance: D- ADMIN CLOSURE Reportability: NOT REPORT ABLE Operability: NOT REQUIRED CR Status: Closed on March 09, 2007 Classification Code: NON-SIGNIFICANT

Description:

During FAC inspection IP3-06-23430, component RHD-02.15A-02E, wall thinning was found on a reheater drain system 6" elbow.

Minimum wall thickness found was 0.10'1". The minimum required thickness for continued operation is 0.233". Nominal wall thickness for this component is 0.432". The wear is concentrated in the elbow extradose. The pipe downstream of the elbow shows some wear in the first 6", but then returns to nominal wall thickness downstream.

The location of this elbow is immediately downstream of a pipe leak found on 7/23/06, CR-IP3-2006-02270. which is to be replaced during 3R14 via WO IP3-06-18240.

Responsible Dept: MAINT-Support Mgmt CA&A

Contact:

Joe Reynolds Originated: 03/09/2007 by Hartjen,Harry G, P&C Eng Codes Staff Affected Systems: Affected Equipment:

Page 58of63

"'U Entergy Operations, Inc. Condition Report List m September29, 200810:12 AM

()

0 0 CR-IP3-2007-01144 Significance: D- ADMIN CLOSURE Reportability:

0

<D Operability: CR Status: Closed on March 13, 2007 I'V CJl

-.....! Classification Code: NON-SIGNIFICANT V>

Description:

During FAC inspection IP3-05-24907, component RHD-02.6A-06L, wall thinning was found on a reheater drain system 6" diameter pipe.

Minimum wall thickness found was 0.226". The minimum required thickness for continued operation is 0.233". The worn area is concentrated on one side of the pipe for its entire length. Nominal wall thickness for this pipe is 0.432".

The worn pipe is located downstream of RHD-LCV-11048 and immediately upstream of the lateral connected to the 10" header. FAC Component RHD-02.6A-05P. The worn pipe is approximately 12" long.

Responsible Dept: P&C Eng Codes Mgmt CA&A

Contact:

Joe Reynolds Originated: 03/13/2007 by Hartjen,Harry G, P&C Eng Codes Staff Affected Systems: HD Affected Equipment: HD CR-IP3-2007-01083 Significance: C - REVIEW & CORRECT Reportability:

Operability: CR Status: Closed on March 16, 2007 Classification Code: NON-SIGNlriCANT

Description:

During FAC inspection IP3-05-24906, component RHD-02.14B-12T, wall thinning was found on a reheater drain system 6" diameter pipe.

Minimum wall thickness found was 0.171 ". The minimum required thickness for continued operation is 0.233". Nominal wall thickness for this pipe is 0.4~~2".

The worn pipe is a pup piece located upstream of the reheater drain line (B Train) inlet nozzle to the 36C Feedwater Heater and immediately downstream of tee RHD-02.14B-12T. The pipe is approximately 6" long.

Responsible Dept: P&C Eng Codes Mgmt CA&A

Contact:

Originated: 03/12/2007 by Hartjen,Harry G, P&C Eng Codes Staff Affected Systems: MFW Affected Equipment: FWH-36C HTX CR-IP3-2007-01307 Significance: D - ADMIN CLOSURE Reportability:

Operability: NOT REQUIRED CR Status: Closed on March 18, 2007 Classification Code: NON-SIGNIFICANT

Description:

During FAC inspection IP3-05-24917, component RHD-02.16A-01 N , wall thinning was found on a reheater drain system 6" diameter pipe.

Minimum wall thickness found was 0.192". The minimum required thickness for continued operation is 0.233". Nominal wall thickness for this pipe is 0.432".

Page 59of63

"'U Entergy Operations, Inc. Condition Report List m September 29, 2008 10:12 AM

()

0 This pipe is a pup piece located upstream of the reheater drain line (A Train) inlet nozzle to the 36C Feedwater Heater and immediately downstream of tee RHD-02.15A-11T. Drawing 0 EC-H-50015. The pipe is approximately 6" long.

0

<D I'V Responsible Dept: P&C Eng Codes Mgmt CJl

-.....! CA&A

Contact:

Joe Reynolds Originated: 03/17/2007 by Hartjen,Harry G, P&C Eng Codes Staff

.j:::o..

Affected Systems: HD Affected Equipment: HD CR-IP3-2007-01449 Significance: C- REVIEW & CORRECT Reportability:

Operability: NOT REQUIRED CR Status: Closed on April 04, 2007 Classification Code: NON-SIGNIFICANT

Description:

During FAC inspection IP3-05-24843, component EX-02.14-07P was inspected and wall thinning was found on the upstream elbow, EX-02.14-06E during the pipe to upstream elbow weld scan. Upon further examination of the weld scan area, additional thinned areas were found on the extradose of the elbow. As the elbow is heavily corroded on the outside surface, this 'best effort' UT exam showed wall thickness of less than 0.170", however a properly prepped surface is required for accurate thickness measurements.. Minimum required thickness for this component is 0.256". The elbow was replaced in 1987 with FAC resistant chrome-moly material and is not expected to wear to this extent due to FAC.

The carbon steel pipe EX-02.14-07P showed little wear and is acceptable for continued service.

Responsible Dept: P&C Eng Codes Mgmt CA&A

Contact:

Originated: 03/21/2007 by Hartjen,Harry G, P&C Eng Codes Staff Affected Systems: EX Affected Equipment: EX, EX-02.14-06E CR-IP3-2007-01516 Significance: D - ADMIN CLOSURE Reportability:

Operability: NOT REQUIRED CR Status: Closed on March 23, 2007 Classification Code: NON-SIGNIFICANT

Description:

During FAC inspection IP3-06-23456 component FAC-07-VCD-09, wall thinning was found on a vent chamber drain system 3" diameter elbow and its downstream pipe.

Minimum wall thickness found was 0.110" The minimum required thickness for continued operation is 0.123". Nominal wall thickness is 0.216".

This elbow and downstream pipe are in the vent chamber drain piping of MSR 31 A. Location is the first elbow downstream of the vent chamber on MSR 31 A. The downstream of the elbow is approximately 12"1ong. Reference piping drawing 9321-f-29033.

Responsible Dept: MAINT-Support Mgmt CA&A

Contact:

Joe Reynolds Originated: 03/23/2007 by Hartjen,Harry G, P&C Eng Codes Staff Affected Systems: HD, TB Affected Equipment: FAC-07-VCD-09, HD, TB

Page 60of63

"'U Entergy Operations, Inc. Condition Report List September 29, 2008 10:12 AM m

()

0 0 CR-IP3-2007-01525 Significance: D- ADMIN CLOSURE Reportability: NOT REPORT ABLE 0

<D Operability: ADMIN- NA CR Status: Closed on March 24, 2007 I'V CJl Classification Code: NON-SIGNIFICANT CJl

Description:

CR-IP3-2007-01516 documents the fact that during FAC inspection IP3-06-23456 on component FAC-07-VCD-09, wall thinning was found on a Vent Chamber Drain System 3" diameter elbow and its downstream pipe and reports an immediate action of, "Generated Work Order IP3-07-17176 and Scope Add Form to replace this elbow and pipe durina 3R14."

In the course of planning Work Order IP3-07-17176, found that Engineering Design Drawing No. 9321-F-29003-4 requires a 2" 45-degree elbow to be welded to the vent chamber discharge nozzle of Moisture Separator Reheater MSR-31 A and with dimensions as shown at coordinates H-2 of that drawing.

Contrary to that requirement, a 2" x 3" expander has been welded to the vent chamber discharge nozzle with dimensions other than as shown at coordinates H-2. It appears that this has resulted in an interference with the insulation on a proximate vertical riser pipe as well as exacerbating the Flow Accelerated Corrosion phenomenon at the 90-degree elbow.

Responsible Dept: System Eng E-FIN Mgmt CA&A

Contact:

Originated: 03/23/2007 by Asquino,Anthony J, PS&O Planning Staff Affected Systems: HD Affected Equipment:

CR-IP3-2007-03588 Significance: C REVIEW & CORRECT Reportability: NOT REPORT ABLE Operability: EQUIPMENT OPERABLE CR Status: Closed on October 26, 2007 Classification Code: NON-SIGNIFICANT

Description:

During FAC inspections of the Aux Feedwater System recirculation piping (51485626**01, 51485627-01, 51485628-01, 51485628-01 and 51485626-02) wall thinning was detected on 2" and 3" piping.

The minimum wall thickness found was 0 .148" for the 2" pipe and 0.24 7" for the 3" pipe. The minimum required thickness for continued operation is 0.141" for the 2" pipe and 0.181" for the 3" pipe per calculation IP-CALC-07-00199. These pipes are acceptable for continued service.

The piping was inspected by UT measurements through the existing paint, requiring a conservative correction factor to be subtracted from the as measured thickness. The calculation also used conservative assumptions in the analysis of this piping. UT measurements found the piping to be uniform thickness with no areas of localized thinninn Since the minimum measured thickness is greater than the required thickness, the piping is structurally sound and is operable.

Responsible Dept: P&C Eng Codes Mgmt CA&A

Contact:

Joe Reynolds Originated: 09/13/2007 by Hartjen,Harry G, P&C Eng Codes Staff Affected Systems: AFW Affected Equipment:

CR-IP2-2007-04405 Significance: C Reportability:

Operability: NOT REQUIRED CR Status: Closed on November 27, 2007 Classification Code: CORRECT/ ADDRESS

Description:

Page 61 of 63

"'U Entergy Operations, Inc. Condition Report List m September29, 2008 10:12 AM

()

0 During eddy current inspection of the #11 Fresh Water Cooling HX (11 FWCHX), it was found that 17 tubes had wall thinning greater than 70%, requiring that they be plugged. Coupled 0

0 with the 11 tubes that were already plugged the percentage of tubes requiring plugging has reached 20.3%, more than the 10% allowed.

<D No operability concern at this time, as the loads normally cooled with the FWCHXs are being supplied with city water.

I'V CJl Responsible Dept: P&C Eng Programs Mgmt (J)

CA&A

Contact:

Originated: 10/30/2007 by Moran,Timothy P, P&C Eng Component Staff Affected Systems: FWC Affected Equipment: 11 FWCHX, FWCHX CR-IP3-2007-04091 Significance: C Reportability:

Operability: EQUIPMENT OPERABLE CR Status: Closed on December 18, 2007 Classification Code: CORRECT/ADDRESS

Description:

Ultrasonic thickness readings (UT) taken on the corroded section of SGBD tank exhaust piping at the Sample Cooler piping branch connection has found pipe wall thicknesses< 87.5%

of nominal pipe thickness. The pipe wall thinning extends beyond the area of external corrosion seen on the pipe outside surface.

Responsible Dept: P&C Eng Codes Mgmt CA&A

Contact:

Joe Reynolds Originated: 11/01/2007 by Allen II,Robert E, P&C Eng Codes Staff Affected Systems: SGBD Affected Equipment: SGBD CR-IP3-2007-04263 Significance: C Reportability:

Operability: NOT REQUIRED CR Status: Closed on January 29, 2008 Classification Code: CORRECT/ADDRESS

Description:

During the 1 year inspection of the 31 SJAE primary elbows A I B I C I D, work order 51477594-01, wall thinning was found on the D elbow.

There is no immediate operability concern.

The minimum thickness found, 0.148" is greater than the minimum required thickness of 0.090" per calculation IP3-CALC-CAR-01996, Rev. 0.

The location on the elbow of the minimum thickness (0.148") in the current inspection, was 0.191" during its previous inspection in December, 2006.

Based on the wear of this elbow since the previous inspection, design engineering needs to review and update the calculation IP3-CALC-CAR-01996, to determine the minimum required thickness and the remaining service life of this elbow.

Responsible Dept: Design Eng Civii/Str Mgmt CA&A

Contact:

Joe Reynolds Originated: 11/14/2007 by Hartjen,Harry G, P&C Eng Codes Staff Affected Systems: CAR Affected Equipment: SJAEC31 HTX

Page 62 of 63

"'U Entergy Operations, Inc. Condition Report List m September 29, 2008 10:12 AM

()

0 0 CR-IP2-2008-02299 Significance: C Reportability: NOT REPORT ABLE 0

<D Operability: NOT REQUIRED CR Status: Closed on May 06, 2008 I'V CJl

-.....! Classification Code: CORRECT/ADDRESS

Description:

UT thickness examination of the two leaking welds U/S of valve SWT 40-1 has identified pipe wall thinning that exceeds 87.5% of nominal pipe wall thickness on both welds. The first weld U/S of valve SWT 40-1 has a minimum thickness of 0.032" and the second weld U/S of valve SWT 40-1 has a minimum thickness of 0.055". These leakinq welds were identified by CR-IP2-07-03279, which was closed to W/0 00119950 toUT these welds.

Responsible Dept: Design Eng Civii/Str Mgmt CA&A Contact; Joe Reynolds Originated: 04/19/2008 by Allen II,Robert E, P&C Eng Codes Staff Affected Systems: SW Affected Equipment: SWT-40-1 CR-IP2-2008-01116 Significance: D Reportability:

Operability: EQUIPMENT OPERABLE CR Status: Closed on March 17,2008 Classification Code: ACTIONS TAKEN

Description:

2R18P PRE-OUTAGE G.L. 89-13 PROGRAM NDE INSPECTION OF SW WELD F-2549 FOUND WALL THINNING BELOW THAT REQUIRED FOR TWO ADDITIONAL YEARS OF SERVICE, REQUIRING REPAIR IN 2R18. REFERENCE NDE REPORT #'s IP2-RT-08-004 AND IP2-UT-08-008. AREA OF CONCERN IS APPROXIMATELY 1" IN DIAMETER.

PIPING AT THIS LOCATION IS NON-lSI PER DRAWING ISI-209762. THIS IS LINE 10" #406 AND IS DOWNSTEAM OF TCV-1103, 1104, AND 1105. ALL WALL THICKNESS READINGS WERE ABOVE THOSE REQUIRED FOR OPERABILITY, BUT SOME WERE BELOW THAT REQUIRED FOR 2 ADDITIONAL YEARS OF SERVICE NECESSITATING REPAIR IN 2R18 NOT 2R19. REFERENCE CALCULATION IP-CALC-06-00067.

PIPING HAS SUFFICIENT REMAINING WALL THICKNESS IN THE AREA OF CONCERN SUCH THAT THROUGH-WALL LEAKAGE BEFORE THE 2R18 OUTAGE IS NOT ANTICIPATED.

WR 00122480 INITIATED FOR WELD REPAIR IN 2R18.

Responsible Dept: P&C Eng Codes Mgmt CA&A

Contact:

Joe Reynolds Originated: 03/07/2008 by Pennino,Dennis P, P&C Codes Staff Affected Systems: SW Affected Equipment: LINE406 CR-IP2-2008-01715 Significance: C Reportability:

Operability: CR Status: Closed on 11,2008 Classification Code: CORRECT/ADDRESS

Description:

During the Ut inspection of the vent chamber piping in 21 B, 22B and 23B MSR the minimum wall thickness found were 0.108 inch, 0.154 and 0.171 inch respectively. In accordance with ENN-DC-315 this condition report was generated to document the wall thinning found below the administrative screening criteria of 60 % of the nominal thickness found in 21 B MSR vent chamber piping. The preliminary calculation determined that the piping will last until 2R20 refueling outage. There is no operability concerns. The piping in the other MSR will last to

Page 63of63

"'U Entergy Operations, Inc. Condition Report List m September 29, 2008 10:12 AM

()

0 0

lit1ene~t sct1ecJ~IePM~ -::J 0 Responsible Dept: P&C Eng Codes Mgmt

<D I'V CA&A

Contact:

Joe Reynolds Originated: 04/03/2008 by Mew,lan, P&C Eng Codes Staff CJl

-.....! Affected Systems: MS Affected Equipment: 21BMSR, 22BMSR, 23BMSR CX>

Report Criteria:

FROM CRSDBA.V_CR_CURRENT ((PLANT_CODE = 'IP2' OR PLANT_CODE 'IP3') AND ((UPPER(CONDITION_DESC) LIKE UPPER('%WALL THINNING%')) OR (UPPER(

SUMMARY

_DESC) LIKE UPPER('%WALL THINNING%')) OR (UPPER(CLOSURE_DESC) LIKE UPPER('%WALL THINNING%'))))