Text
EA-11-142 UNITED STATES NUCLEAR REGULATORY COMMISSION REGION IV 612 EAST LAMAR BLVO, SUITE 400 ARLINGTON, TEXAS 76011.4125 November 17, 2011 Donna Jacobs, Vice President, Operations Entergy Operations, Inc.
Waterford Steam Electric Station, Unit 3 17265 River Road Killona, LA 70057-0751
SUBJECT:
WATERFORD STEAM ELECTRIC STATION, UNIT 3 - FINAL SIGNIFICANCE DETERMINATION OF WHITE FINDING; NRC INSPECTION REPORT 05000382/2011009
Dear Ms. Jacobs:
This letter provides you the final significance determination of the preliminary White finding discussed in NRC Inspection Report 05000382/2011009, dated August 24, 201 1. The finding involved the failure to use effective engineering controls to reduce radioactive contamination and subsequent exposure. Waterford Steam Electric Station personnel failed to keep highly radioactive water from leaking onto the work areas around the reactor coolant pumps. This failure resulted in high levels of radioactive contamination and unexpected and unintended radiation dose to plant workers.
At your request, a regulatory conference was held on October 3, 2011, to discuss your views on this issue. A copy of the Waterford Steam Electric Station's presentation that was provided at the meeting is enclosed (see Enclosure 1). In addition, on October 13, your staff provided a written response (see Enclosure 2) to additional questions raised by the NRC during the regulatory conference. During the meeting, you and your staff provided perspectives on this finding. In particular, you indicated that Waterford Steam Electric Station personnel appropriately followed all of the as low as reasonably achievable (ALARA) procedures and that the additional radiation dose was related to equipment deficiencies. Therefore, you concluded that there was no performance deficiency and no finding. You maintained that the use of engineering controls to reduce contamination from leaking reactor coolant was beyond the ability of Waterford personnel to plan for because the equipment failures were beyond the control of your staff and could not be anticipated or predicted. However, as described in further detail below, the NRC determined that your staff should have anticipated leaking reactor coolant from one or more reactor coolant pump seals and then planned for and installed effective engineering controls to mitigate the spread of highly contaminated water.
The NRC reviewed all the information presented at the regulatory conference, as well as the supplemental information that your staff provided after the conference. The NRC staff determined that based on operating experience. including known fuel defects and a planned crud burst with anticipated seal leakage, there was sufficient information available to anticipate the likely consequences and plan accordingly. From as early as 2005, Waterford Steam Electric Station personnel had knowledge that the reactor coolant pump seals were likely to leak. At
Donna Jacobs least one or more reactor coolant pump seals leaked during each shutdown/outage starting in 2005. Additionally, the NRC staff found that there was no supporting information provided by your staff that would mitigate the significance determination for the preliminary White finding.
In Refueling Outage 14, the leakage of radioactive water raised the dose rates in work areas around the reactor coolant pumps by 35 percent, according to the information provided by your staff. In planning for Refueling Outage 16, Waterford Steam Electric Station personnel had collected industry information and had planned for fuel failures because of fuel design changes.
This was acknowledged by your staff and documented in NRC Inspection Report 05000382/2011 OOg, Attachments 2, 3 and 4.
In spite of the known fuel defects and planned crud burst with anticipated reactor coolant seal leakage, Waterford Steam Electric Station personnel failed to install an effective leak collection system to collect and control the seal leakage. The resulting contamination of work areas caused unnecessary personnel dose well in excess of the original ALARA dose estimates.
Based on this, the NRC has concluded that the finding is appropriately characterized as White (i.e., a finding with a low-to-moderate importance to safety that may require additional NRC inspections). Using Inspection Manual Chapter 0609, Appendix C, "Occupational Radiation Safety Significance Determination Process," the finding was determined to be White because (1) this was an ALARA planning issue, (2) the site's 3-year average collective dose exceeded 135 person-rem and (3) one of the work activities accrued more than 25 person-rem or alternatively, the finding would still be White because there were more than four other occurrences in which the actual collective dose exceeded 5 person-rem, and the estimated/planned dose by more than 50 percent.
You have 30 calendar days from the date of this letter to appeal the staff's determination of significance for the identified White finding. Such appeals will be considered to have merit only if they meet the criteria given in the IMC 0609, Attachment 2. An appeal must be sent in writing to the Regional Administrator, Region IV, 612 East Lamar Boulevard, Suite 400, Arlington, TX 76011-4125.
The NRC has also determined that no violation of a regulatory requirement occurred. The Waterford Steam Electric Station, Unit 3, ALARA program was adequate and a violation of 10 CFR 20.1101 (b) did not exist. Additionally, the NRC did not identify an inadequacy associated with radiation protection procedures required by Technical Specification 6.8.1, Programs and Procedures,~ and Regulatory Guide 1.33, "Quality Assurance Program Requirements (Operation).~
You are requested to respond to this letter by providing the corrective actions that have been taken or planned to correct this finding and prevent recurrence. If you have additional information that you believe the NRC should consider, you may provide it in your response to this finding.
Because plant performance for this issue has been determined to be beyond the licensee response band, we will use the NRC's Action Matrix to determine the most appropriate NRC response for this event. We will notify you, by separate correspondence, of that determination.
Donna Jacobs In accordance with 10 CFR 2.390 of the NRC's "Rules of Practice," a copy of this letter, its enclosures, and your response, if you choose to provide one, will be made available electronically for public inspection in the NRC Public Document Room or from the NRC's document system (ADAMS), accessible from the NRC Web site at http://www.nrc.gov/reading-rm/adamS.html. To the extent possible, your response should not include any personal privacy, proprietary, or safeguards information so that it can be made available to the Public without redaction.
Docket: 50-382 License: NPF-38
Enclosures:
- 1. Waterford Steam Electric Station, Unit 3 Regulatory Conference Presentation
- 2. Waterford Steam Electric Station, Unit 3 Response to The NRC's Regulatory Conference Questions cc: Listserve (Waterford)
Sincerely,
{fLo ~ eRL Elmo E. Collins Regional Administrator
WATERFORD STEAM ELECTRIC STATION, UNIT 3, REGULATORY CONFERENCE PRESENTATION October 3, 2011
Re2:ulatory Conterence October 3, 2011 WATERFORD STEAM ELECTRIC STATION UNIT 3 NRC RADIATION SAFETY INSPECTION REPORT 05000382/2011009; PRELIMINARY WHITE FINDING 1
enlng KemarKS Waterford 3 Perspective o Reactor coolant pump vapor seal de staging o Waterford 3 has taken mitigating actions o Waterford 3 has made significant improvements in current plant performance 2
Opening Remarks Donna Jacobs - Waterford 3 Vice President Collective Radiation Exposure (CRE)
Refuel Outage Refuel 17 m""'M' "
. ' "~,
L*.*(
~.... :,:_
,_,:,,:.f*~
I, '-'. r
- r*, ~,
~
't.
, ",t t*
,- ". 'T.....:
3
VHH.Lg RemarKs Presentation Outline o Engineering - Bruce Proctor o Refuel Conditions - Daryl Marse o Radiation Protection - Jeff Brawley o Regulatory Perspective - Billy Steelman o Closing Remarks - Donna Jacobs 4
Waterford 3 Design o Combustion Engineering 2 Loop Design o Four Reactor Coolant Pumps o Reactor Coolant Pump Vapor Seal Design 5
~
8..
~
i II :i
~
.. ~
~
~
i...
=
I!
~
~
Engineering Reactor Coolant Pump Vapor Seal Summary o September 2005 - Reactor coolant pump vapor seal de staging o March 2006 - Operating procedure changes o
January 2007 - Vendor evaluation started o September 2008 - Vendor evaluation and testing complete o October 2009 - Reactor coolant pump seal installed at ANO o
November 2009 - Refuel 16 installed trough modification o
April 2011 - Refuel 17 two reactor coolant pump seal packages replaced 7
EngIneerIng Refuel 16 Modification o Trough modification performed in Refuel 16 o Permanently installed engineered control o Trough modification established at accommodate unexpected source terms 8
Waterford 3 Refuel 16 Planned Activities o Pre-outage power reduction and clean up plan o Reactor coolant system dose equivalent iodine and reactor coolant system degassing plan o
Shutdown Cooling Purification o Cobalt cleanup plans o Operating Experience 9
\\..u\\ *.uation ProtectIon Pre-Outage ALARA Planning o Reactor coolant pump Radiation Work Permit planning o Radiation Work Permit expected conditions o Reactor coolant pump vapor de staging pre-planned contingencies 10
Refuel 16 Unplanned Conditions o Reactor trip (moisture separator reheater) o Fuel pin defects o Additional cleanup o Reactor coolant system acid reducing duration 11
Radiation ProtectIon Unexpected Conditions Response o Initiated Radiation Work Permit revisions o Analyzed impact of emergent conditions o Documented and briefed Radiation Work Permit revisions o Executed ALARA contingency actions 12
ALARA Improvements o Installed trough modification o Replaced two reactor coolant pump seal packages o Purchased additional tungsten shielding including tungsten vests o Increased the amount of shielding o Added new shielding applications 13
~uu~ation ProtectIon ALARA Improvement Statistics RF16 RF17 Outage Dose
~250 Rem
~98 Rem Personnel Contamination 128 21 Events 14
Regulatory Perspective o IMC 0308 Reactor Oversight Process (ROP) o IMC 0609 Appendix C Occupational Radiation Safety Significance Determination Process 15
Closing Remarks o Reactor coolant pump vapor seal leakage o Waterford 3 took reasonable actions o Waterford 3 has implemented ALARA improvements 16
WATERFORD STEAM ELECTRIC STATION, UNIT 3, RESPONSE TO THE NRC'S REGULATORY CONFERENCE QUESTIONS
The NRC requested additional information during the Radiation Protection preliminary white finding regulatory conference. The questions and responses are provided below:
- 1) Provide the pre-refuel 15 predicted fuel defects and the actual as found number.
Provide the pre-refuel 16 predicted fuel defects and the actual as found number.
Response
The Refuel 16 (RF1 6) ALARA plan was developed considering the increased number of fuel defects expected at the beginning of RF16 versus the number of actual fuel defects at the beginning of RF15 as discussed below. This plan would have reduced the activity in the RCS during RF16 to the levels experienced during RF15 considering the increased number of fuel defects expected and, absent the reactor trip, would have successfully addressed the unexpected increase in the number of actual fuel defects found in RF16.
Based on Chemistry isotopic concentrations, predicted vs. actual fuel failures for the Cycle 15 core were as follows:
Predicted: 5-10 leaking fuel rods Actual: 11 leaking rods Based on Chemistry isotopic concentrations, predicted vs. actual fuel failures for the Cycle 16 core were as follows:
Predicted (9/18/09): 40 leaking fuel rods Actual: 55 leaking fuel rods
- 2) From the chemistry planning perspective, how were the known fuel defects incorporated into the plan. How was the difference from refuel 15 and 16 addressed?
Response
The chemistry cleanup plan was developed using the Reactor Coolant System (RCS) isotopic activity and RCS isotopic ratios as the measures to determine cleanup requirements. These measures were used to directly address the differences between the RF15 and RF16 fuel defect conditions. Additionally, using these measures addressed uncertainties in the projected number of RF16 fuel cladding defects and the limited information related to cladding defect size.
Based on the cleanup plan, months prior to the start of Refuel 16 (RF16), sixty hours were added to the outage schedule for extra RCS clean-up compared to RF15. This cleanup time was included in the time from when the reactor is secured to the time of hydrogen peroxide addition. The additional schedule time was added to delay hydrogen peroxide addition time, based on information found in the EPRI Pressurized Water Reactor Primary Water Chemistry Guidelines. The EPRI guidelines states that iodine is harder to remove once oxidized and can convert to iodate which can be an airborne hazard once the RCS is opened to atmosphere.
Following the unplanned reactor trip this initial plan had to be adjusted to add even more RCS cleanup time prior to the hydrogen peroxide addition.
Page [ 01'30
See Attachment 1 for the details of the RCS clean-up plan that was developed prior to the outage; a summary of the plan is reflected below.
PLAN
SUMMARY
Minimize impact to outage by reducing RCS iodine and cobalt activities.
Remove Radioactive gases from the RCS, in particular Xe-133 Enter RF16 with a the following to ensure clean-up capabilities:
o Fresh 1.0 micron Chemistry and Volume Control (CVC) system filter o
Two fresh CVC mixed bed ion exchangers o
Contingency resin on site Plant down power preceding the shutdown for refueling to ~wash out" the fuel pins to reduce RCS Dose Equivalent Iodine (DEI) spike following the plant shutdown approximately 5 days prior to the RF16 shutdown.
o Come down to 80% reactor power.
o Wait for the Xenon peak (4 to 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br />) o Return to 100% power at 3% per hour RCS Fission Gas Plan o
Reduce Gaseous Waste Management (GWM) system leakage.
o Fix relief valve PSL-3091 and leakage from valve PSL-3061 to allow Pressurizer venting to the Volume Control Tank (VCT) vice Hold-Up Tank (HUT) A.
o Prior to outage, conduct controlled venting of the VCT to reduce RCS Xenon gas activity o
During outage, control vent the VCT to lower RCS Xe-133 to 0.16 uCi/ml, this equates to containment atmosphere of 0.03 Derived Air Concentration (DAC) noble gas if all Reactor Coolant Pump (RCP) vapor seals destage RCS clean-up to preset lodine-131 target activity to reduce impact of RCS isotopic activity on RCP seal leakage.
o Continue operation of 2 charging pumps up until plant shutdown.
o After plant trip. run 3 charging pumps during plant cool down to -350F and -1 100 psia.
o Clean-up RCS lodine-131 to 4.5 E-03 uCi/ml, this equated to 0.3 DAC in containment if all RCPs destage.
o Place Shutdown Cooling (SOC) system in service and add Hydrogen Peroxide (H202) for forced oxidation of RCS cobalt Page 2 or 30
- 3) From the radiation planning perspective, how were the known fuel defects incorporated into the plan? How was the difference from refuel 15 and 16 addressed?
Response
There were fuel cladding defects going into Refueling Outages 13, 14, and 15; however, the magnitude of the defects was comparatively lower than in RF16. In RF13, RF14, and RF15, the RCS isotopic activity was cleaned-up using on-going experience with past practices as a guide. Experience had shown that typical clean-up measures had been effective, with no markedly different actions needed to address the fuel cladding defects. That is, following each of those outages, RCS clean-up was effectively performed using the typical clean-up plans. However, during cycle 16, it was recognized that the amount of fuel cladding defects would require additional measures to manage the clean-up. This prompted the development of an RCS DEI and Bulk Water clean-up plan. Isotopic concentration has a direct correlation to dose rates and the plan was developed with this knowledge. Implementation of the plan was an integral aspect of controlling dose to ALARA, including the prevention of radioactive gas uptake.
The anticipated radiological impact due to the iodines and noble gasses from the anticipated fuel cladding defects was incorporated into the Refuel 16 ALARA Planning process. For example, Radiological Work Permits factored in the use of HEPA filtration and incorporated utilization of charcoal banks when applicable to mitigate the iodines. ALARA planning for Refuel 16 was predicated on chemistry results of the Reactor Coolant System (RCS) through the cycle that did not indicate a rise in Cobalt activity (hard gamma isotopes). ALARA planning considered a peak of 3 uci/ml of Cobalt 58 in the RCS after the H202 addition.
The RF16 plan established radiological precautions based on the assumption that the RCS DEI and Bulk Water clean-up plan would mitigate the additional iodines in the RCS along with noble gases discussed above. Refuel 15 was started with predicted 5-10 leaking fuel rods, which was less than the projected 40 leaking fuel rods in RF16. Since the RCS DEI and Bulk Water clean-up plan was comprehensive and actions from the plan were executed in the refuel schedule, the ALARA staff relied on the plan to mitigate the isotopic source term such that there would be no negative impact on the dose estimating process.
See Attachment 1 for details of the RF 16 RCS clean-up plan that was developed prior to the outage. The information on the following page reflects the basic difference in the level of activities taken to clean-up the RCS between RF15 and RF16.
Page 3 of 30
Key RCS Clean-up Plan Attributes Pre-refuel 15 Water Management Plan that included the following:
a letdown ion exchanger strategy a
letdown IiIter strategy CE-002-006, Maintaining Reactor Coolant System Chemistry, formalized direction on primary forced oxidation of cobalt and primary cleanup Projected Co-58 cleanup curve Pre-refuel 16 RCS DEI and bulk water degassing plan contained the following:
o Iodine and crud cleanup philosophy a
RCS gas removal plan o
Pre-outage prep action time line a
Letdown resin loading o
Letdown ion exchanger strategy a
Cleanup plan for down power to 80% power for iodine washout a
Chemistry sampling and communications plan (beyond typical) o Projected RCS DEI cleanup curve o
Projected RCS Co-58 cleanup curve o
Timeline o
RCS cleanup flow chart CE-002-006, Maintaining Reactor Coolant System Chemistry, formalized direction on primary forced oxidation of cobalt and primary cleanup
- 4) What would have prevented shroud dam installation prior to 350 psi? Provide the sequence from RCS pressure of -600 psi down to where the shroud dams were actually installed.
Response
Waterford 3 has four Reactor Coolant Pumps (RCPs) and the operations shutdown procedure secures two RCPs early in the shutdown process once power operations have concluded and the pumps are no longer needed. For refuel 16. two RCPs were secured at -2250 psia. The remaining two RCPs are not secured untit after shutdown cooling is placed in service.
Shutdown cooling entry conditions are 392 psia and 350 F. Operations shutdown procedure uses two reactor coolant pumps for forced circulation untit after shutdown cooling is initiated and appropriate plant conditions have been obtained. The operations shutdown procedure requires RCPs remain in operation during the cooldown and depressurization until Chemistry reports Cobalt-58 activity in RCS has peaked. For refuel 16. the last two RCPs were secured at -350 psia.
Page 4 of30
Prior to installation of the Rep shroud dams, activities are completed to clearance tag the Rep for personnel safety. Additional impacts to installation of the shroud dams are the physical "heat stress" environment during this time due to ambient temperature from just shutting down the plant.
In Refuel 16, shroud dams and drain lines were installed in Rep 1A because this was the first Rep secured.
RCP 2A shroud dam installation did not immediately occur. Dose rates of 65-120 mRem/hr subsequently developed in the area from the leaking seals. The estimated dose to install the dam with this dose rate was approximately 600 mRem. Because of the dose rate, a decision was made based on ALARA to delay installation of the shroud dams until depressurization of the ReS and decontamination of the area had been completed. The shroud dams were installed following decontamination of the area and the area dose rates had lowered.
RCP 1 B was secured at -350 psia. When an attempt was made to start the shroud dam and drain line installation when the pump was secured, a dose rate of 200-300 mRem/hr precluded the installation. The estimated dose to install the dam with this dose rate was approximately 1500 mRem. The shroud dams were installed later following decontamination of the area and the area dose rates had lowered.
RCP 2B was secured at -350 psia. Also, there were already high dose rates in the shroud area due to isotopic deposits from RCS leakage that occurred during Cycle
- 16. Actual dose rates measured during the start of RF16 were 350-700 mRem/hr; the estimated dose to install the dam with this dose rate was approximately 2900 mRem. Because of the 350-700 mRem/hr dose rate, a decision was made based on ALARA to delay installation of the shroud dams. The shroud dams were installed later, following decontamination of the area and the area dose rates had lowered..
- 5) For the Reactor Coolant Pump shroud dam installation, what was the pre-planned expected dose field and total dose if we had done the installations. What was the actual as found conditions and basis for not installing the Reactor Coolant shroud dams?
Response
During refuel 16, Rep 1A and 2A were the first Reps secured. Rep 1 Band 28 were secured after shutdown cooling was initiated.
RCP 1A expected dose rates in the shroud from the as left surveys in RF15 were 6-8 mRem/hr (estimated dose for installation was 42 mRem), actual dose rates measured during the start of RF16 were 8 - 10 mRem/hr, estimated dose to install the dam in these dose was approximately 54 mRem. Waterford 3 did install the shroud dams on RCP 1A prior to the destaging of its vapor seal.
RCP 1 B expected dose rates in the shroud from the as left surveys in RF15 were 15
-18 mRem/hr (estimated dose for installation was 100 mRem), actual dose rates measured during the start of RF16 were 200-300 mRem/hr, estimated dose to install the dam with this dose rate was approximately 1500 mRem. Waterford 3 did not initially install the shroud dams on Rep 18 prior to its vapor seal leaking because the Page 5 01"30
pump was needed to operate to support plant conditions. By the time the pump was secured, its vapor seal had leaked and there was a dose rate of 200-300 mRem/hr (as indicated above). Because of the high dose rates, a decision was made based on ALARA to delay installation of the shroud dams. The shroud dams were installed later, following removal of the insulation and decontamination of the area to minimize recontamination of the area during plant startup. The consequence of the decision to delay installation of the shroud dams was evaluated, which concluded that the net outage dose would have been higher if the dams had been installed. Specifically, a review of the subsequent dose rate surveys shOWed no substantial changes in dose rates in the Rep shroud areas over the next several days. Thus, it is concluded that not having the dams in place did not cause the area dose rates to be higher. The delay resulted in lower dose to install the shroud dams because the dose rates had lowered following removal of the insulation and decontamination. The result was that there was lower dose received for this work.
Rep 2A expected dose rates in the shroud from the as left surveys in RF15 were 10 mRem/hr (estimated dose for installation was 60 mRem), actual dose rates measured on 10/25/09 after the seals had destaged were 65-1 20 mRem/hr, estimated dose to install the dam with this dose rate was approximately 600 mRem.
Waterford 3 did not initially install the shroud dams on Rep 2A prior to its vapor seal leaking. As noted above, dose rates of 65-120 mRem/hr subsequently developed in the area from the leaking seals. Because of the high dose rates, a decision was made based on ALARA to delay installation of the shroud dams. The shroud dams were installed later, following decontamination of the area to minimize recontamination of the area during plant startup.
Rep 2B expected dose rates in the shroud from the as left surveys in RF15 were 8 ~
15 mRernlhr (estimated dose for installation was 70 mRem), actual dose rates measured during the start of RF16 were 350~700 mRem/hr, estimated dose to install the dam with this dose rate is approximately 2900 mRem. Waterford 3 did not initially install the shroud dams on Rep 2B prior to its vapor seal leaking because the pump was needed to operate to support plant conditions. By the time the pump was secured, its vapor seal had leaked and there where dose rates of 350~700 mRem/hr in the area. Because of the high dose rates, a decision was made based on ALARA to delay installation of the shroud dams. The shroud dams were installed later, following decontamination of the area to minimize recontamination of the area during plant startup. The consequence of the decision to delay installation of the shroud dams was evaluated, which concluded that the net outage dose would have been higher if the dams had been installed. Specifically, a review of the subsequent dose rate surveys showed no substantial changes in dose rates in the RCP shroud areas over the next several days. Thus, it is concluded that not having the dams in place did not cause the area dose rates to be higher. The delay resulted in lower dose to install the shroud dams because the dose rates had lowered following removal of the insulation and decontamination. The result was that there was lower dose received for this work.
In summary, the pre outage RF16 planned dose to install dams in RCP 1A, 1B, 2A, and 2B shrouds was approximately 272 mRem. Based on the actual radiological conditions observed during the start of RF16 it would have cost approximately 4500 mRem.
Page 6 of 30
The decision to defer installation of the shroud dams and drain lines on Reps 1 B, 2A, and 2B was made because the Rep seals had leaked onto the insulation packages and dose rates were elevated. A review of the dose fields showed that once the RCP vapor stages started leaking the dose rates elevated and remained at the elevated level until decontaminated occurred. Since, the dose rates prior to and after the planned shroud dam installation remained similar; the delay in shroud dam installation did not adversely affect the accumulated doses.
- 6) For the Reactor Coolant Pump work, provide an estimate of how much dose was due to dose equivalent iodine and how much was due to cobalt.
Response
The following reflects RCS isotopic concentrations when the Rep's were secured during RF1 6. (NO = Not Detectable) 1-131 1-132 1-133 1-134 1-135 Co-58 Co-50 Isotone uci/ml uci/ml uci/ml uci/ml uci/ml uci/ml uci/ml When Reps 1A and 6.44E-3.35E-7.26E-1.07E-4.65E-2.07E-2A were secured 01 01 01 01 01 1.24E-01 03 When Re ps 1 B and 3.69E-2.14E-28 were secured 02 NO NO NO NO 4.70E+OO 02 Cs-138 Rb-88 Nb-95 Kr-85m Kr-87 Kr-88 Xe-133 Isotope uci/ml uci/ml uci/ml uci/ml ucilml uci/ml uci/ml When Reps 1A and 1.84E-2.11E-8.25E-5.62E-2.88E-9.14E-2A were secured 02 01 03 02 02 02 1.77E+00 When Re ps 18 and 2B were secured NO NO NO NO NO NO 1.65E-01 Xe-133m Xe-135 Fe-59 Mn-54 Ni..65 Sb-125 Zr-95 Isotone uci/ml uci/ml uci/ml uci/ml uci/ml uci/ml ucilml When Re ps 1A and 4.26E-3.92E-9.58E-8.58E-1.00E-2A were secured 02 01 03 NO 03 NO 02 When Re ps 1 B and 6.15E-1.69E-28 were secured NO NO NO 03 NO 02 NO Page 7 01' 30 Zr-97 uci/ml U 6E-02 NO
- 7) Was it reasonable to know we were going to be in an acid reducing state for 96 hours0.00111 days <br />0.0267 hours <br />1.587302e-4 weeks <br />3.6528e-5 months <br /> instead of 60 hours6.944444e-4 days <br />0.0167 hours <br />9.920635e-5 weeks <br />2.283e-5 months <br />? Should we have anticipated the delay? What was the basis for the 36 hours4.166667e-4 days <br />0.01 hours <br />5.952381e-5 weeks <br />1.3698e-5 months <br />?
Response
The time that it took to clean up the ReS to reduce RCS DEI down to 4.5e-3 uCi/ml has a direct correlation to the amount of time in the acid reducing phase. The acid reducing phase begins when Operations borates the RCS to high concentrations shortly after the plant is shutdown. The acid reducing phase ends once the H202 is added to the RCS. Any discussion on what prompted delays in adding the H202 also explains the extended time in the acid reducing phase.
The extra RCS clean-up time of 30 hours3.472222e-4 days <br />0.00833 hours <br />4.960317e-5 weeks <br />1.1415e-5 months <br /> was added within 2 hours2.314815e-5 days <br />5.555556e-4 hours <br />3.306878e-6 weeks <br />7.61e-7 months <br /> of the plant trip leading into RF16. The plant tripped -30 hours earlier than the planned shutdown was to commence. A decision was made to take advantage of this period to clean the RCS, especially since it was known that the trip caused an unexpected, higher crud burst that would need additional time to clean-up. Note that actual duration was 36 hours4.166667e-4 days <br />0.01 hours <br />5.952381e-5 weeks <br />1.3698e-5 months <br /> due to continuing efforts to clean RCS DEI.
The original ReS clean-up time of 60 hours6.944444e-4 days <br />0.0167 hours <br />9.920635e-5 weeks <br />2.283e-5 months <br /> was based on two inputs: a prediction of the end of cycle RCS DEI values, known clean-up rates, and expected plant conditions. How this was calculated follows:
The end of cycle RCS DEI values were predicted based on the existing cycle 16 RCS DEI trend extrapolated to the end of cycle. The projected RCS DEI at shutdown, along with known clean-up rates and plant conditions, were then used to determine the time needed to get the RCS DEI down to the target level of 4.5e-3 uCi/ml. Achieving this value would limit containment atmosphere iodine to
< 0.3 DAC jf the RCPs destaged.
Post trip ReS DEI was based on taking the RCS end of cycle DEI value and multiplying it times a calculated constant. The constant is comprised of the ratio of historical RCS post trip DEI concentration peaks against historical end of cycle RCS DEI concentrations (see below for equation).
Post trip DEI prediction = (EOC DEI)*(Historica/ post trip DEli historical EOG DEI)
Once the ReS post trip DEI was estimated, known cleanup rales were used to estimate cleanup time to RCS DEI to 4.5e-3 uCi/ml. Achieving this value would limit containment atmosphere iodine to < 0.3 DAC if the RCPs destaged.
Was it reasonable to know before the outage that we were going to be in the acid reducing state for 96 hours0.00111 days <br />0.0267 hours <br />1.587302e-4 weeks <br />3.6528e-5 months <br />? Prior to RF16, Waterford 3 could not have known we were going to be cleaning up the RCS DEI for 96 hours0.00111 days <br />0.0267 hours <br />1.587302e-4 weeks <br />3.6528e-5 months <br />. The initial plan included 60 hours6.944444e-4 days <br />0.0167 hours <br />9.920635e-5 weeks <br />2.283e-5 months <br /> of clean-up. The plant trip prompted the addition of 30 hours3.472222e-4 days <br />0.00833 hours <br />4.960317e-5 weeks <br />1.1415e-5 months <br /> clean-up time. The nature of the trip, cycle history of elevated ReS DEI and fission gases and the elevated level of RCS DEI post trip required additional RCS fission product cleanup time. The additional time is direclly connected to the plant trip. The plant trip could not have been predicted therefore the extension of the cleanup time could not have been predicted.
Page 8 of 30
Should we have anticipated the delay? The plant trip was unexpected and could not have been foreseen. The decision to add additional cleanup time was made following the trip. Prior to the outage Wateriord did not know the exact number and size of the fuel defects. This information is only known after fuel has been removed from the reactor and inspected. The size and number of fuel defects are important factors in how much and when fission products will be released from leaking fuel pins. Since this information is only known after fuel inspections and the trip was unexpected, any delays in ReS fission product cleanup could not have been predicted.
What was the basis for the extra 36 hours4.166667e-4 days <br />0.01 hours <br />5.952381e-5 weeks <br />1.3698e-5 months <br />? Following the Reactor trip from 100%
power, 30 hours3.472222e-4 days <br />0.00833 hours <br />4.960317e-5 weeks <br />1.1415e-5 months <br /> were added in order to remove iodine from the RCS prior to securing the Reps. The plant tripped -30 hours earlier than the planned shutdown was to commence. A decision was made to take advantage of this period to clean the ReS, especially since the trip caused an unexpected, higher crud burst. The time added delayed the hydrogen peroxide addition, for reasons listed in question 2.
As the ReS was depressurized, the fuel conlinued to leak fission gases into the RCS bulk water; thus, the final six hours of cleanup following the previously added 30 hours3.472222e-4 days <br />0.00833 hours <br />4.960317e-5 weeks <br />1.1415e-5 months <br />.
- 8) When was the first Radiation Work Permit (RWP) 20090513 revision? What was factored in?
Response :
RWP 20090513, Rep 1A Motor and Driver Mount Removal and Replacement, including all Supporting Activity Task 1 for Rigging was revised on 11/10109. The revision for Task 1 factored in higher dose rales than projected due to high ReS activity.
Task 2 for Rep Motor Work was also revised on 11 /10/09. The revision for Task 2 factored in higher dose rates than projected due to high ReS activity.
Task 3 for Driver Mount Work was also revised on 11/10109. The revision for Task 3 factored in issues associated with working with the jacking mount tooling used to separate the driver mount from the pump. The driver mount experienced thermal binding with the pump casing.
Task 4 was for the associated Inspections; it was not revised during revision 1 because the actual dose received was within the RWP estimates. Also, there was a limited amount of work periormed under that task at time of the RWP revision.
Revisions to this RWP were periormed in accordance with fleet procedure, EN-RP-105, Radiological Work Permits. RWP revisions are required prior to exceeding 125% of the dose estimates. The original dose estimated in the RWP was 13.590 Rem, and the accumulated dose was 10.190 at time of the first revision. The first revision occurred at approximately 75% of the initial RWP dose estimate.
Page 9 oflO
Attach men! 1 Page 10 01' 30
RCS CLEAN UI' "LAN FOR REFUEL 16 RFt6 DEI Cleanup \\Vindow Optimization Plan I'urpose-Provide basis, limits, and instructions for ReS cleanup, to minimize effects of dc-staging Reactor Coolant pumps, and subsequent release of reactor coolant into containment. Cleanup limits are 4.5E-3 uCi/ml for ReS DEI and 1.6E-1 uCi/ml for ReS Xc-133.
111al11 Conditions-Following reactor shut down, three charging pumps will be placed in service to raise available letdown flow to - 120 grm. Operations wi ll commence a slow cool down to between 350 and 365F. This will maintain the planl in Mode 3 and allow three charging pUIllP operation. A slow cool down will maintain a high (100 gpm) letdown now rate by minimizing shrinkage or the Pressurizer volullle. ReS Pressure will be reduced to between 1000 and 1200 PSIA to maintain control ofletdown now and provide margin to the dc-staging pressure of the RCP Seals (-600 PSIA).
Key Assumptions-End of cycle and peak RCS DEI and RCS Xe-133 values are predictcd based on previous cycle histories. RCS DEI is projected to peak at.06 uCi/ml to 0.3 uCi/ml. This is based on assumption that power reduction will lower post shutdown spike activities similar to those observed in RFI5.
Plan Goals:
o MinimIze impact to outage by reducing ReS iodine and cobalt activities.
o Remove Radioacti ve gases from the RCS, in particular Xe-133 o
Maintain a reducing environment during the majority of RF 16 acid reducing conditions, i.e. prior to peroxide addition o
Establish pre-planned communications and decision logic tree for Outage Control Center Personnel (Sec Figure I, attached) o Enter RF 16 with a the following:
Fresh 1.0 micron cve rilter Two fresh eve mixed bed ion exchangers Fresh Spent Fuel Pool Ion Exchanger.
Page II or30
rLAN
SUMMARY
Plant down power preceding the shutdown for refueling.
o Come down to 80% power.
o Wait for the Xenon peak (4 to 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br />) o Return to 100% power at 3% per hour o
- 5 days prior to RF 16 shutdown o
Purpose to "wash out" the fuel pins to reduce the DEI spike following shutdown for RF 16.
ReS cleanup to preset lodine-13l target activity to reduce impact of Rep seal leakage.
o Continue operation 01'2 charging pumps up until plant shutdown.
o At1cr plant trip run 3 charging pumps during plant cooldown 10 - 350F and
- 1100 psia.
o Cleanup lodine-131 to 4.5 E-03 uCi/mi (0.3 DAC).
o Go on 1 traill ofSDC and add H202 (second cleanup).
- Res Gas Plan o
Reduce Gaseous Waste management (GWM) leakage.
a Vent PZR steam space to VeT, burps of veT beginning -4 weeks prior to shutdown o
Continue burping VCT to reduce RCS Xenon gas activity.
o Calculated target value 0.16 uCi/ml (0.03 DAC noble gas)
Other work was also evaluated to start early and the following list of activities will be pulled up into this window:
- 1. WO 52023395 MT A deluge
- 2. Tagout FP-004
- 4. SIO00027 VENT SITS TO 235. 300 rSIG IF CONTAINMENT ATMOSPHERlC CONDITIONS ALLOW
- 5. liang 1 R 16-1 /MT -002-A-MT B -> Work Orders: 00186925-01, 00153330-01 (NEED TO CHANGE Tagout boundaries
- 6. SECURE SCW PER OP*03*022
- 7. Hang CD*026, and CD*027
- 8. wo 52022793 MT Deluge Testing
- 9. WO 186137 UAT DclugeTesting 10.01'*903*033 FW MVAAA 173 A, 00086217*10, 00181035*04, 00182700*07, 00185389*06
- 11. 0]'*903*033 FW MV AAA 173 8 00197308*0 I, 00197308*02, 00182554*07, 18 1034*06 Page 1201"30
12.01'-903-033. FW MVAAAI66A, 00186196-01,
- 13. 01'-903-033, FW MVAAAI66B, 00181868-08,181040-06 14.01'-903-033, MS MVAAAI16A, 00200679-04, 15.01'-903-033, MS MVAAAI16B 00200679-03
- 16. WOOOI86295-01, 01'-903-126 SECT 7.1 (ATT IO.I)COMM SYSAND ALARM TESTING 17.51644159-02, OI'S TO REMOVE & RESTORE CEAC CIINL "2" FROM SER VICE FOR MA IN
- 18. Tagoul SSD-004 and 5SD-005 temp power (should be online)
- 20. Tagoul MT-OOOI A (Boundaries need to be changed)
- 21. Tagolll FI-IS-003
- 22. Hang I R 16-I/CED -003- -EPNL0002 UF -> Work Orders: 00185725-01
- 23. Hang IRI6-I /CED -004- -EPNL0004 UF -> Work Orders: 00185739-01
- 24. Hang I R 16-lnK V -001--1 B OUTAGE -> Work Orders: 00154028-01, 00154028-02,00154028-05,00182 142-01,00182143-01 (NEED TO CHANGE Tagout boundaries)
- 25. Hang MS-004 WO 153498 (NEED TO CHANGE Tagollt boundaries)
- 26. Hang ES-OO 1, (need to change boundaries)
- 27. I-land MS-022, (need to change boundaries)
- 28. liang lRIG-l /eD -013- -ERELI37 1 B-> Work Orders: 5 1662303-01 It may be possible to start work on the Polar Crane Pre-Service Inspection ifambicnt temperatures are towered enough using containment purge. A trigger point of 92 F wet bulb temperatures has been sello slarl this work. Iflhis trigger is reached, work will begin on the polar crane pre-service inspection.
Page 13 of30
I)rccautions and Limitations:
Fuel leaks have resulted in elevated ReS iodine, cesium and xenon activities. Based on industry OE, this will result in delays getting into containment for outage start and possible large number of personnel contaminations and containment evacuations during RF 16 if not properly cleaned up.
EPR1, PWR Chemistry Guidelines, section 2.4.2.2, indicates that iodine must be removed from the primary coolant prior to peroxide addition. Based on Operating Experience from ANO and Calvert Cliffs, we can anticipate the potential of the Chromatograph Effect. The Chromatograph EfTect follows the RCS going from reducing to oxidizing, wh ich coverts Iodide to Iodate and starts to migrale through the ion exchanger and eventually ehltes from the vessel. This lesson learned was factored into lhe ion exchanger strategy.
Based on end of cycle RCS DEI-1 3! projection along with post shutdown DEI-13 1 spike, RCS DEI-131 is expected to spike above technical specification limit of 1.0 uCiiml.
Plant Management, Licensing. and Emergency Planning were notifi ed and CR-W F3-2009-2866 was generated. Currently EP is working on revision to the EAL Procedure being tracked by CR-WFJ-2009-2959 CA2, which would elmnge the Unusual Event entry criteria to 60 uCi/ml.
Plan is designed to lower baseline Reactor Coolant noble gas activity to reduce the likelihood of containment noble gas concentration exceeding 0.3 OAC following leakage from the Reactor Coolant pump seals. A spike in RCS noble gas activity will mOSI likely occur following the plant shutdown and dcpressurization of thc RCS to atmospheric pressurc. Venting may begin earlier to minimize any effect on pOlential plant shutdown.
Once Volume Control Tank venting is started, venting should continue every three to four days 10 prevent re-equilibrium of Reactor Coolant gas activities back to pre venting levels. Venting interval may reqUIre check and adjusts as we proceed.
Pre Outage Conditions:
- CVC Filter 1.0 micron
- eve IX A Purification
- eve IX B Isolated
- eve IX e Delithating
- FP[ X Purification Current IX Pcrform:tI1l.'c:
eve IX A DF is 3379 CVC IX B DF is Isolated eve IX e DF is 11 21 Scheduled for replacement 10/8/09 In Service 8/28/09 Scheduled for replacemcnt 9118/09 Used Nightly In Service 8129109 FP[ X DF is 2, low OF is due to low activity on influent.
Page 1401'30
System Cas Behavior:
U ~~~'-':"tc~~-'::!t:-~~c':t~~
1 Sal 8S.~1 15 Sal T,~
RCS gas conccntrations come to equilibrium in 3 to 4 days. Volume Control Tank venting al frequencies greater than 4 days will not take advantage of gas equilibrium in the Reactor Coolant System. Previous vcnt removed 30% of RCS Xc-133 activity.
1)lan Objectives:
Venting the RCS to reduce RCS Gas Inventory lodinc removal by running elevated letdown prior to the outage Optimizing the use of the CVCIX to have efficient removal of Iodine and Cobalt isotopes.
Manipulating plant power and shutdown rate (based on input from Reactor Engineering), five days prior to the outage, to reduce isotopic production and to allow time for cleanup prior 10 containment entry.
I-lard gamma, principally Co-58, from crud burst will be c1caned up using pre-established Chemistry procedures.
Iodine & Crud Cleanup:
CVC filter is scheduled lor rcplacement on 10/8/09 with a 1.0 micron filter for use during RF 16 shutdown. This wil l allow un-intcrrupted filtration during crud burst portion of RFI6.
Having two cve ion exchangers available at shutdown (8& C) will achieve an optimal environment for Iodine and Cobalt rcmoval as needed once Increased Shutdown Cooling now is achievcd.
Running 80 gallons per minute of chargi ng has cui pre-outage ReS DEI in half.
Removal ofCVClX A (Lithiated Purification Bcd) to be removed from service prior to shutdown, reserved as contingency or available for startup.
Page 15 of30
RCS Cas Rcmov:lllll:lII:
Plan calls for venting to drive RCS gas activity down prior to activity coming back to equilibrium. Plan also removes Pressurizer steam space activity via the Volume Control Tank. Plan is optimized to provide the lowest Reactor Coolant System gas activity immediately prior to RF [6, thus no venti ng is required in August. Inilial activities on the initial VCT burp will be used to detenninc a RCS gas inventory which will be used to alter the venting plan if necessary.
The time line page which follows In this report outl ine the actions necessary to result in as low as reasonably achievable RCS bulk water noble gas concentrations. A target limit of 1.6E-1 uCi/m[ Xe-133 RCS bulk water limil has been established 10 result in less than O.3DAC noble gas once dispersed in CTMT Atmosphere from the estimated leakage from RCP destaging.
Gas Decay Tanks A & C should remain in service while hydrogen over pressure is on the Volume Control Tank.
Gas Decay Tank B should be placed in service when nitrogen is place on Volume Control Tank as necessary to maintain non-explosive mixtures of Hydrogen and Oxygen gas.
Page 16 of30
Pre-Outage Preparation Action Time Line Table:
DATE ACTION STATUS OWNER TRACKING 5115/09 Perfoml RCS Particle Complete Jeff Bourgeois LO-OLW-Size Study Results recommend maintaining 0.45 micron filtration until 2009-139-92 month before outage then replace with 1.0 micron.
5/23/09 Reload CVC IX C with Complete ors Plant Schedule Ociithating Resin 6116/09 Start 2no Charging Complete Jeff Bourgeois N/A Pump RCS DEI was cut from 3.2E*02 uCi/ml to 1.6E*02 u(i/ml within 30 hours3.472222e-4 days <br />0.00833 hours <br />4.960317e-5 weeks <br />1.1415e-5 months <br />.
7/8/09 Place CVC IX A & B Complete Jeff Bourgeois N/A in Series However, CVC lX B had 10 be removed from service on 711 1109, due to an OPS procedure issue to facilitate efficient Ociithaling with CYCIX C.12:oin o forward.
7115/09 Rinse CVClX C and Complete Jeff Bourgeois N/A placc in service for CYClX C is operating as expeCled with OF of 855 when in Delithiation usc.
8/24/09 Ensure OPS procedures Complete David JOI)'
LO-OLW-will support cleanup Ensurclverify Operations Procedures will allow for Chemical 2008-139 plan Volume Control [on Exchangers B and C to be place in CAIOO service in parallel approximately 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> prior to the start o PS procedure ofRF16 with either I, 2, or 3 charging pumps running. Also can not support ensure/verify that when Shut down cooling purification is parallel aligned that both CYCIX B & C can stay in parallel operation.
Plan revised.
8/4/09 -
Submit EAL change to In Progress, NRC is challenging the station, and Ihis Bob Murillo CR-2009-2959 10/15/09 NRC and revise EAL change may not happen.
CA02 limit from 1 to 60 uCi/ml RCS DEI Page 17 0f30
8/28/09 Sluice & Reload FPI X Complete 8/28/09 Jeff Bourgeois Plant Schedule WR-167095 (lOcu ft C-J8 1-1i & 25 cu ft NR-35LC)
Resin is in Gramercy and available within 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> 8/27/09 Sluice & Reload eve Complete 8/26/09 Jeff Bourgeois Plant Schedule IXA WR-167093 (35 cu ft NR-20LC)
Resin is staged on RAB +2 1.
8/28/09 Rinse eve IX A and Complete JclT Plant Schedule place in service as OPS performs as requested by Chemistry Bourgeois Purilication IX 8/29109 Ptace FPI X in service Complete Jeff Plant Schedule OPS performs as requested by Chemistry Bourgeois 911 8109 Sluice & Reload eve Scheduled 9118/09 (On track)
JelT Plant Schedule IXB
\\VA 202560 (35 cu ft NR-6LC)
Bourgeois 10/8109 Replace CVC Filter Scheduled 1018109 (On-track)
Daryl Marse Plant Schedule with 1.0 micron WO 197893 Filter is in stock 101 2109 Off load Spent Resin RP is handling the off load of the SRT fo llowing the sluice CuBie Miller LO-OLW-Tank of CVCIX B and the start of RF 16 2008-139 CA IOI 10114109 Shutdown ramp rates/de Complete Leia Milstcr 80% Down rate unit per RXE input Evaluate Down power to 80% 5 days prior to RF I6.
power approved 5 days prior to RFI 6 10/20109 Start A RRS, Airborne Scheduled Ron Stanley Plant Schedule Radiation Removal System Page 18 of30
SFP and eve I~ esin Loading:
FPIX (Relldy for RFI6 in service 8/29/09) 15 cu ft of Macro reticular (C-38 1-1-1) &
20 cu ft ofNR*35LC (2: I Marco Cation to Gel Anion)
This loading gives a good balance Cation to Anion removal which will control Iodine, Cesium, and Cobalt in the SFP and RX cavity during the outage. The Sluice and Reload latc August should ensure capacity through Ihc Refuel.
CVCIX A (Ready for RFI6 in service 8/28/09) 35 cu ft of NR-20LC (I: I Gel Cation to Gel Anion) Lithiated Resin This Loading will improve Iodine, Cesium,,md Cobalt removal going into RF 16, and will not remove Lithium from tbe RCS, therefore not afTect pH. It can be taken out of service just before RFI6 and saved for start up for cycle 17.
CVC IX B (Sluice & Reload Scheduled 9118/09) 35 ell ft of N R-6LC (I: I Gel Cation to Gel Anion)
Tbis Loading will be efTective at Anion Removal more targeted at Iodine and Cesium, with reasonable balance for Cobalt and Hard Gamma Emitters. CYCIX 13 will be the main Ion Exchanger lIsed for Iodine Cleanup the first part of the Refuel.
CVC IX C (Ready for RF16 in service 7/ 16/09) 15 cu ft of Macro reticular (C-381-H) &
20 cu ft ofN R-35LC (2: I Marco Cation to Gel Anion)
This Loading will be effective at Calion Removal more targeted at Cobalt and I-lard Gamma Emitters, with reasonable balance for Anions such as Cesium and Iodine.
CVClX C wi[1 serve as a rcady ion exchanger post peroxide add, and the main ion exchanger for cobalt clc<lllup.
Page 190[30
eve Ion Exchanger Strategy:
I. 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> prior to shutdown remove CVCIX A [rom service
- 2. 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> prior to shutdown place CVClX B in service
- 3. Cleanup to 4.5E-3 uCi/ml RCS DEI
- 4. Place onc train of Shut down Cooling in serviec
- 5. Bypass CVCIX B for Peroxide Add
- a. Add Peroxide to the RCS
- 6. Verify RCS is Oxidizing
- a.
Place CVClX C in service
- 7. Monitor and Determine Cobalt Peak
- a.
Secure Reactor Coolant Pumps
- b. Cool Down Pressurizer
- 8. Place Shut down Cooling Purification in Service
- 9. Place CVCIX B in service (Parallel with CVCIX C)
- 10. Monitor evcl X Emuent
- a.
If Iodine starts to rise on CVClX B Eftluent then Isolate CVClX B
- b. IfCVCIX B gets isolated, make decision on need for contingent sluice and reload Hard Spot: CVCIX B will be sluiced and reloaded on 9/ 18/09, it will require rinsing to be placed in service 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> prior to shutdown. Suggest using increased level in VCT during VCT burps as RCS inventory to periodically rinse CVCIX B prior to outage while boron is still relatively high.
Solution: Since Boron is low it is estimated the rinse will take about 10-12 hours of total rinse time to get 130ron in specification with the RCS. Operations Outage Liaison has agreed the Operations can support periodic rinses of CVCIX B in combination with the scheduled VCT burps on every other Sunday leading up to the outage, which will reduce the final rinse time prior to placing in service. This has been incorporated into the plant schedule.
Page 20 of 30
eve Ion Exchanger Basis:
CYCIX A can not be used during the shutdown as il would pul Lithium in the RCS and cause the system to go reducing after going oxidizing. By removing CYC1X A prior to the oUlage allows CYCIX A to rinse on startup and we can startup with a Purification Ion Exchanger for Cycle 17.
CVC1X 13 bcing placed in service 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> prior to shutdown will remove lithium, and is loaded with resin capacity and selectivity to be efficient at Iodine removal. Bypassing CVCIX B during the Peroxide add is a precaution and is recommended in the Failed Fuel Guidelines. The Primary Chemistry Guidelines do not require this, and this will be a di fference from ANO and Calvert Cli ITs.
Due to the Chromatograph effect seen at Calvert Cliffs, CYCIX C will be used mainly after thc Pcroxide addition.
AND did not see the "Chromatograph Effect", which is an increase on their IX Eflluent.
Waterford Chemistry will monitor the IX Efnuent ofCVCIX B once placed back in service. When SOC Purification is placed in service, CVCIX B wi ll be used again to support 240 GPM cteanup flow in parallel with CVCIX C.
If CVCIX B l~ fflu e nt rises above 4. 5E-3 on Iodine on two samples, it should be removed from service and implementation ofconlingcney for resin replacement considered.
Contingencies:
During RF 16. if CVC filte r exhausts based on dose or differential pressure, filter should be changed out with new filter. Size to be determined by Chemistry based on plant conditions at time of occurrence. CYC filter rcplacement is scheduled during RF 16; this package could be moved up in the outage as needed.
If CVC IX exhausts, ion exchanger should be sluiccd and reloaded with new resin. (LO-OLW-2008-139 CA 102, assigned to chemistry to ensure 15 ell ft of Macro reticular (C-381-11) & 20 Cll ft ofNR-35 LC (2:1 Marco Cation to Gel Anion) is on site during RFl6 as a contingency item. (LO-OLW-2008-139 CA I 04), assigned to RP to cnsure a contingency packagc for CVCIX Sluice and Reload is planned and ready.
Unexpected IJllint Shutdown:
Line up Pressurizer Steam Space to Volume Control Tank Burp Volume Control Tank based on Chemistry input Secure Pressurizer Steam Spacc to Volume Control Tank when vcr vcnting is adequate.
CVCIX are available for usc and should be placed in/out of service based on Chemistry recommendations and conditions or thc plant shutdown.
Page 2 1 01"30
w C
U 0:
Predicted Effects of Cycle 16 Downpower to 80% to RF-16 RCS DEI Cleanup Prior to De-Pressurization 1.00E+OO r=
=b 1-- - ---------.. 0.3 DEI Based on ----=+/-
fcs Clean Up Prediction based upon: -
1.00E-01 1.00E-02 0;
M
~
w....
~ -
";M -
~
Gustov Spike ------_+_
.06 and 0.3 uCi/ml DEI peaks
-/--=-
~ ~
+/-
____ --S:-..-''.... ---=t-----
~
~--+----
.06 DEI historical spike
-1
. -.-=--:--=-.--=-. _. -. _. -. -. -. -. _. _. _. -'-=:' _. _. _.
~
- r
-+-
One Train of SOC in*service Assumes down power to 80% returning to 100%
power preceding RF16 shutdown. Shutdown iodine levels based on historical refuel shutdown iodine spikes and impact of Cycle 14 down power preceding RF14 Iodine spike six hours after shutdown with 3 Charging Pumps @ 120 gpm Predicted <0.3 DAC in Containment from RCP Seals with target 1-1314.5 E-03 uCi/ml 1.00E-03 !
~---
- -j-.f-
~-
Predicted hydr~en peroxide addition
-+--
1.00E-04 0
6 12 18 24 Page ¥'.z o f 30 36 42 48 54 60 66 Hours Since Shutdown 72
~,
c * "
u iil o
~,
c *
- u U
0:
~ -..
0:
o *
~
I~
g
- w 8 r
I I
I I
T I ~
e",
0_
t I
I t
t '
I t
I I I
- 1) w g
o w o
Timeline:
Berore IlF I6:
Sept 14 Sept 15 Sept 18 Sept 19 Sept 19 Sept 21 Sept 21 Sept 22 Sept 23 Sept 27 Sept 27 Sept 28 Sept 30 Oct 4 Oct 4 Oct 5 Oct 6 Oct 7 Del II Oct II Del 12 Ocl14 Oct 16 Oct 16 Oct 18 Oct 18 Oct 19 Oct 19 Oct 20 Ocl 20 Sample vcr and RCS for gas activity Line up Pressurizer Steam Space to Volume Conlrol Tank per CE-003-327 Sluice and Rcload CVCIX B (WO-202560)
Secure Pressurizer Steam Space 10 Volume Control Tank per CE-003-327 Burp Volume Conlrol Tank Sample VCT and RCS for gas aClivity Line up Pressurizer Steam Space to Volume Conlrol Tank per CE-003-327 Secure Pressurizer Steam Space 10 Volume Control Tank per CE-003-327 Burp Vol ume Control Tank Burp Volume Control Tank Rinse CVCIX B (Use waler from vcr burp, do not place IX in service)
Sample VCT and RCS for gas activity Burp Volume Control Tank Burp Volume Control Tank Rinse CVCIX B (Use water from VCT burp. do nOI place IX in service)
Sample VCT and RCS for gas activity Line up Pressurizer Steam Space to Volume Control Tank per CE-003-327 Burp Volume Control Tank Burp Volumc Control Tank Rinse CVCIX B (Use water from vcr burp, do not place IX in service)
Sample vcr and RCS for gas activity Bu'l> Volume Control Tank Plant will down power to facilitate cleanup RCS DE I samples every 4 hours4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br /> to profi le Iodine behaviors during down power.
BUll> Volume Control Tank as much as possible following return to 100% power Rinse CVCIX B (Use water from vcr burp, do nol place IX in service)
Reduce VeT pressure to maintain RCS Hydrogen to 25-30 cclkg Samplc VCT and RCS for gas activity Secure CVCIX A Place CVC IX B in service (final ri nse if necessary)
All above activities were verified by PS&O to be in the pl:lllt schedule liS of 9/10/09.
Page 24 of 30
Outage:
OCI 2 1 Oct 2 1 Oct 2 1 Oct 22 Oct 22 OCI 22 Oct 22 Oct 22 Ocl 22 Oct 22 Oct 22 OcI 22 Oct 22 OCI 23 0<123 Oct 23 Oct 23 OCI23 Multiple Volume Control Tank burps while maintaining hydrogen greater than 15 cc/kg in the Reactor Coolant System ors Maximizes Purification Flow (3 Charging Pumps when possible)
Chemistry Sample & Analyze in accordance with Sampling and Communication Plan Reach 4.5E-3 uCi/ml RCS DEI Place one train of Shutdown Cooling in service Bypass CVCIX B Switch in service Gas Decay Tank to B as necessary based on Ilydrogen/Oxygen Add Hydrogen Peroxide per CE-002-006 Chemistry verify RCS oxidizing Place CVCIX C in service Chemistry monitor for Cobalt Peak Secure Reactor Coolant Pumps OPS cool down Pressurizer Place SDC puri fi cation in service Place CVCIX B in service (in parallel with CVCLX C)
Utilize SDC Increased Purification Flow to 240 gpm with CVCIX B & C in Parallel Chemistry Monitor CVCIX Effluent for Iodine Exhaustion Chemistry sample every 4 hours4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br /> [or hard gamma cleanup monitoring and communicate results to OCC with updated cleanup curves.
All above activities were requested to be verified by I'S&O Refuel to be in the outage schedule on 9/10/09.
Page 25 0 1' 30
Chemistry Sampling & Communication Plan:
I'rimary Saml)linc Plall:
l'uqJOse:
Resources:
Days:
Nights:
RCSI)onsibilities:
Monitor ReS DEI, Res Xenon, ReS Boron, ReS llydrogcn, & veT Ilydrogcn to provide technical data for monitoring of Primary side cleanup for RF 16.
Chemistry Tcchs: ROllnie Lac.y (Lead) & Gene Plaisance (Support)
Chemistry Supervisor:.lei/Bourgeois Chemistry Techs: Chad Jackso/l (Lead) & A imey 7)"egre (Support)
Chemistry Supervisor: DalY! Marse Chemistry Techs:
Sampling & analysis of Primary systems in accordance with site procedures at frequencies designated by this plan, COMS, plant/outage schedule, and Chemistry Supervision request.
Chemistry SUI)v:
Reviewing Primary Data as it is generated, updating cleanup curves, communicate primary sample results to the acc as defi ned by this plan, site procedures and OCC communications protocol.
Sampling & Analysis Table:
NOTE: This table wi ll not include any routine analysis designated by plant mode & CE-OO I-004 Periodic Scheduling & Analysis Program ; requirements of CE-OO 1-004 still ~pply. The Resources necessary for the completion of the ordinary Primary sampling and analysis have been factored into the technician resources al located to the primary side of the plnnt.
Res Boron will be sampled "nd analyzed to support OI)S request, historically about 30 times within the first 36 hours4.166667e-4 days <br />0.01 hours <br />5.952381e-5 weeks <br />1.3698e-5 months <br /> of the shutdown.
4 hours4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br /> prior to shutdown:
Sample RCS for Gross (Gases) & Degas (Iodine) for ODMI Sample VCT for baseline Activity & lIydrogen Page 26 of30
At shutdown:
Sample & Communicate RCS for Gross (Gases & Iodine) for spike and recovery every 30 minutes until four data points are obtained in the downward direction for both Xe-133 & DEI.
Sample RCS for DEI 2-6 hours following thermal power change of 15% in one hour for TS, this sample should be a Degas sample, this sample ean substitute one of the 30 minute samples in the previous bullet.
Sample RCS per Chemistry Supervisor recommendations for RCS conditions to verify RCS achieves and maintains an acidic reducing environment. See CE-002-006 for monitored parameters.
RCS should be monitored for Hydrogen at least 4 times per shift, at approximately 0200, 0800, 1400, & 2200 until Peroxide Addition occurs. Communication of this data to the OCC will occur on next routine update following the analysis results being available.
VCT should be sampled for Activity & Hydrogen twice per shift at approximately 0200, 0800, 1400, & 2200 for the first 48 hours5.555556e-4 days <br />0.0133 hours <br />7.936508e-5 weeks <br />1.8264e-5 months <br /> of RF 16, and then Chemistry Supervision may extend sampling frequency based on trend data and plant needs.
Communication of this data to the OCC will occur on next routine update following the analysis results being available.
Once downward trend is established for Xenon & Iodine:
Extend Sampling & Communication to an hourly frequency for RCS Gross (Gases &
Iodine).
Once trend data and projected estimates conclude that Iodine target of 4.5E-3 uCi/ml DEI will be reached within 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br />, sample frequency for RCS Gross (Gases &
Iodine) should return to once per 30 minutes.
Once 4.5E-3uCi/ml DEI in RCS is reached, then transition to Cobalt Cleanup Monitoring:
Following Peroxide addition to the RCS, Sample and Analyze RCS for Cobalt Peak every 30 minutes until two data points indicate a lowering trend on Cobalt 58.
Results will be communicated to the ace Following Cobalt Peak detemlination extend sample and analysis frequency to once per two hours. Also monitor CVCIX Ernuent for Iodine break.
Once Cavity Flood up limit of 5.0E-2 uCi/ml Hard Gamma Emitters has been reached, follow CE-OO [-004 and Chemistry Supervision Guidance for additional sampl1ng.
Communicating Sample Results:
Results will be communicated to the OCC by the Pnmary Chemistry Supervisor Jeff Bourgeois (Days) & Daryl Marse (Nights). Once peak Iodine & Cobalt values are determined, projections will be recalculated and communicated via, phone to the RP/CHEM OCC lead at x3299. An updated graph for Iodine & Cobalt will also be sent via email. Other related parameters will be communicated by email on Table I; example is on the next page.
Page 27 of 30
Table I Chemistrv Results Communicated to acc Date Time ReS Gas RCS Xc-RCS RCS H2 VCT Act VCTH2 RCS RCS Act 133 Boron (cc/Kg)
(uCi/m[)
(%)
Acidic?
Reducing?
(uCi/ml)
(uCifml)
(ppm)
I (YESINO) I (YESINO)
Page 28 of 30
Figure 1 INVESTIGATE PURIFICATION FLOW RCS CLEANUP FLOWCHART 24 HOURS PRIOR TO SHUTDOWN REMOVE "A" AND PlACE "8" CVCS IX IN-SERVICE PLANT SHUTDOWN INITIATE SAMPLING SCHEDULE DEI PEAK ACHEIVED PLOT NEW RCS CLEANUP CURVE 8ASED ON PEAK DEI VALUE & TIME SINCE SHUTDOVVN REDUCE RCS 1-131 ACTIVITY TO 4.5 E~3 uCilml CONTINUE DEGASSING RCS DURING IODINE CLEANUP Xenon-131 targel1.6 E~1 uCilml NO Ensure flow is maximized 1-_..... (
IS RCS 1-131 ACTIVITY LOWERING AS PROJECTED?
PROVIDE Rx ENG ISOTOPICS FOR REVIEW YES L ______________________ _
1 Continued on Page 21 Page 29 01'30 NO CHECK OF OF IX "8" FOR IODINE "8" IX OF <2 YES EVALUATE REMOVAL OF 8 IX FROM SERVICE, PlACE C IX IN-SERVICE MONITOR CLEANUP &
IX-C OF FOR IODINE 1
Continued on Page 21
RCS CLEANUP FLOWCHART Continued from Page 1 CONTINUE SAMPUNG AND DEGASSING PlAN r----------------------
CONTINUE SAMPUNG AND DEGASSING PLAN
- MONITOR IX OF
- PROVIDE Rx ENG
- ISOTOPICS FOR REVIEW OF FAILED FUEL CONDITION NO HAS ReS '.131 LOWERED TO 4.5 E.(I3 uCl/ml?
r------------------
YES CONTINUE DEGASSING THE RCS THROUGH THE veT NO IS THE Xe-113 ACTIVITY <0.3 OAe?
YES Res CLEANUP &
DEGASSING COMPLETE Page 30 01"30 NO Continued from Page 1 IS NEW CLEANUP DURATION PROJECTION >24 HOURS YES CONSIDER SLUICE AND RELOAD OfIX-B