ES-401, Rev. 9E PWR Examination Outline Form ES-401-2 Facility:

Harris 2011-301 Date of Exam: July 2011 RO K/A Category Points SRO-Only Points Tier Group

T F

KKKKKKAAAAG A2

(

G*

ITotal 1234561234 Total L___

1.

1 3

3 3

3 3

3 18 3

3 6

Emergency &

Abnormal Plant 2

1 2

2 N/A 1

2 N/A 1

9 2

2 4

Evolutions

Tier Totals 4

5 5

4 5

4 27 5

5 10 1

32313233233 28 3

2 5

2.

Plant 2

01111111111 10 1

1 1

3 Systems TierTotals 33424344344 38 5

3 8

3. Generic Knowledge and Abilities 1

2 3

4 10 1

2 3

4 7

Categories 2

2 3

3 1

2 2

2 Note:1.

Ensure that at least two topics from every applicable K/A category are sampled within each tier of the RO and SRO-only outlines (i.e., except for one category in Tier 3 of the SRO-only outline, the Tier Totals in each K/A category shall not be less than two).

2.

The point total for each group and tier in the proposed outline must match that specified in the table. The final point total for each group and tier may deviate by +/-1 from that specified in the table based on NRC revisions. The final RO exam must total 75 points and the SRO-only exam must total 25 points.

3.

Systems/evolutions within each group are identified on the associated outline; systems or evolutions that do not apply at the facility should be deleted and justified; operationally important, site-specific systems that are not included on the outline should be added. Refer to ES-401, Attachment 2, for guidance regarding the elimination of inappropriate K/A statements.

4.

Select topics from as many systems and evolutions as possible; sample every system or evolution in the group before selecting a second topic for any system or evolution.

e.

Absent a plant-specific priority, only those K/As having an importance rating (IR) of 2.5 or higher shall be selected. Use the RO and SRO ratings for the RO and SRO-only portions, respectively.

6.

Select SRO topics for Tiers 1 and 2 from the shaded systems and K/A categories.

7*

The generic (G) K/As in Tiers 1 and 2 shall be selected from Section 2 of the K/A Catalog, but the topics must be relevant to the applicable evolution or system.

8.

On the following pages, enter the K/A numbers, a brief description of each topic, the topics importance ratings (IRs) for the applicable license level, and the point totals (#) for each system and category. Enter the group and tier totals for each category in the table above; if fuel handling equipment is sampled in other than Category A2 or G* on the SRO only exam, enter it on the left side of Column A2 for Tier 2, Group 2.

Use duplicate pages for RO and SRO-only exams.

9.

For Tier 3, select topics from Section 2 of the K/A catalog, and enter the K/A numbers, descriptions, IRs, and point totals (#) on Form ES-401 -3. Limit SRO selections to K/As that are linked to 10 CFR 55.43.

ES-401, Rev. 9 2

Form ES-401 -2 ES-401 PWR Examination Outline Form ES-401-2 Emergency and Abnormal Plant Evolutions

- Tier 1/Group 1 (RO / SRO)

EIAPE # / Name / Safety Function K

K K

A A

G K/A Topic(s) lR

.. g OO7EK1.05 Knowledge of the operational 33/38 000007 (BW/E02&E1 0; CE/E02) Reactor Trip X

implications of the following concepts as they

- Stabilization

- Recovery / 1 apply to the reactor trip:

Decay power as a function of time.

000008 Pressurizer Vapor Space Accident / 3

009EG2.4.20 Knowledge of the operational 38/43 000009 Small Break LOCA /3 X

implications of EOP warnings, cautions, and notes.

011 EK2.02 Knowledge of the interrelations 2.6/2.7 000011 Large Break LOCA / 3 X

between the and the following Large Break LOCA: Pumps

O1IEG2.4.9 Knowledge of low power/shutdown 3.8/4.2 00001 1 Large Break LOCA / 3 (SRO) x implications in accident (e.g., loss of coolant accident or loss of residual heat removal) mitigation strategies.

015AK3.03 Knowledge of the reasons for the 3.7/4.0 000015/17 RCP Malfunctions (4 X

following responses as they apply to the Reactor Coolant Pump Malfunctions (Loss of RC Flow): Sequence of events for manually tripping reactor and RCP as a result of an RCP malfunction

022AA2.03 Ability to determine and interpret the 3.1/3.6 000022 Loss of Rx Coolant Makeup /2 X

following as they apply to the Loss of Reactor Coolant Makeup: Failures of flow control valve or controller

025AA2.02 Ability to determine and interpret the 4.0/4.2 000025 Loss of RHR System / 4 (SRO)

X following as they apply to the Loss of Residual Heat Removal System: Leakage of reactor coolant from RHR into closed cooling water system or into reactor building atmosphere

025AA2.01 Ability to determine and interpret the 2.7/2.9 000025 Loss of RHR System / 4 X

following as they apply to the Loss of Residual Heat Removal System: Proper amperage of running LPI/decay heat removal/RHR pump(s)

026AA1.O6Abilitytooperateand/ormonitorthe 2.9/2.9 000026 Loss of Component Cooling Water / 8 X

following as they apply to the Loss of Component Cooling Water: Control of flow rates to components cooled by the CCWS 027AK1.01 Knowledge of the operational 000027 Pressurizer Pressure Control System X

implications of the following concepts as 3.1/3.4 Malfunction /

they apply to Pressurizer Pressure Control Malfunctions: Definition of saturation temperature

029EK2.06 Knowledge of the interrelations 2.9/3.1 000029 ATWS I I X

between the and the following an ATWS:

Breakers, relays, and disconnects

029EA2.02 Ability to determine or interpret the 4.2/4.4 000029 A1WS / 1 (SRO)

X following as they apply to a ATWS:

Reactor trip alarm

038EA1.36 Ability to operate and monitor the 4.3/4.5 000038 Steam Gen. Tube Rupture /3 X

following as they apply to a SGTR: Cooldown of RCS to specified temperature

WE12EK1.3 Knowledge of the operational 000040 (BW/E05; CE/E05; W/E1 2) Steam X

implications of the following concepts as they 34/37 Line Rupture - Excessive Heat Transfer / 4 apply to the (Uncontrolled Depressurization of all Steam Generators) Annunciators and conditions indicating signals, and remedial actions associated with the (Uncontrolled Depressurization of all Steam Generators).

054AA1.01 Ability to operate and I or monitor the 4.5/4.4 000054 (CE/E06) Loss of Main Feedwater / 4 X

following as they apply to the Loss of Main Feedwater (MFW): AFW controls, including the use of alternate AFW sources 000055 Station Blackout / 6

056AG2.2.25 Knowledge of the bases in 3.2/4.2 000056 Loss of Off-site Power / 6 (SRO)

X Technical Specifications for limiting conditions for operations and safety limits.

000057 Loss of Vital AC Inst. Bus / 6

058AA2.01 Ability to determine and interpret the 3.7/4.1 000058 Loss of DC Power! 6 (SRO)

X following as they apply to the Loss of DC Power:

That a loss of dc power has occurred; verification that substitute power sources have come on line

062K3.04 Knowledge of the reasons for the 3.5/3.7 000062 Loss of Nuclear Svc Water! 4 X

following responses as they apply to the Loss of Nuclear Service Water: Effect on the nuclear service water discharge flow header of a loss of CCW

065AG2.2.44 Ability to interpret control room 4.2/4.4 000065 Loss of Instrument Air I 8 X

indications to verify the status and operation of a system, and understand how operator actions and directives affect plant and system conditions.

077AG2.2.37 Ability to determine operability 3.6/4.6 000077 Generator Voltage and Electric Grid X

and/or availability of safety related equipment Disturbances / 6

WEO4EA2.1 Ability to determine and interpret W/E04 LOCA Outside Containment / 3 X

the following as they apply to the (LOCA Outside 344.3 Containment) Facility conditions and selection of appropriate procedures during abnormal and emergency operations.

WEO4EG2.1.23 Ability to perform specific system W/E04 LOCA Outside Containment /3 (SRO)

X and integrated plant procedures during all modes of plant operation.

WE1 1 EK3.4 Knowledge of the reasons for the W/E1 1 Loss of Emergency Coolant Recirc. /4 X

following responses as they apply to the (Loss 3.6/3.8 of Emergency Coolant Recirculation) RO or SRO function within the control room team as appropriate to the assigned position, in such a way that procedures are adhered to and the limitations in the facilities license and amendments are not violated.

WEO5EK2.1 Knowledge of the interrelations BW/E04; W/E05 Inadequate Heat Transfer -

X between the (Loss of Secondary Heat Sink) and 37/39 Loss of Secondary Heat Sink / 4 the following: Components, and functions of control and safety systems, including instrumentation, signals, interlocks, failure modes, and automatic and manual features.

K/A Category Totals:

[3 3

3 3 3J3 Group Point Total:

18 SRO K/A Category Totals:

[ = =

= TI 3 Group Point Total:

6

ES-401, Rev. 9 3

Form ES-401-2 ES-401 PWR Examination Outline Form ES-401-2 Emergency and Abnormal ant Evolutions-Tier 1/Group 2 (RO / SRO)

E/APE # / Name / Safety Function K

K K

A A

G K/A Topic(s)

IR

--i-000001 Continuous Rod Withdrawal / 1 X

OO1AK2.01 Knowledge of the 2.9/3.2

interrelations between the Continuous Rod Withdrawal and the following: Rod bank step counters 000003 Dropped Control Rod I 1

000005 Inoperable/Stuck Control Rod / 1

000024 Emergency Boration I 1

000028 Pressurizer Level Malfunction / 2 X

028AK2.03 Knowledge of the 2.6/2.9

interrelations between the Pressurizer Level Control Malfunctions and the following: Controllers and Positioners 000028 Pressurizer Level Malfunction / 2 (SRO) x 028AA2.04 Ability to determine and 2.6/3.1

interpret the following as they apply to the Pressurizer Level Control Malfunctions: Ammeters and running indicators for CVCS charging pumps 000032LossofSourceRangeNl/7

000033 Loss of Intermediate Range NI / 7 000036 (BW/A08) Fuel Handling Accident / 8

000037 Steam Generator Tube Leak / 3 X

037AA1.02 Ability to operate and I or 3.1/2.9

monitor the following as they apply to the Steam Generator Tube Leak: Condensate exhaust system 000051 Loss of Condenser Vacuum / 4 X

051AK3.01 Knowledge of the reasons for

2.8/3.1 the following responses as they apply to the Loss of Condenser Vacuum: Loss of steam dump capability upon loss of condenser vacuum 000051 Loss of Condenser Vacuum / 4 (SRO)

X 051AG2.4.8 Knowledge of how abnormal 3.8/4.5 operating procedures are used in conjunction with EOPs.

000059 Accidental Liquid RadWaste Rel. /

059AK3.01 Knowledge of the reasons for

the following responses as they apply to the Accidental Liquid Radwaste Release:

Termination of a release of radioactive liquid 000060 Accidental Gaseous Radwaste Rel. / 9

000061 ARM System Alarms / 7

000067 Plant Fire On-site / 8

068AA2.03 Ability to determine and 40/42 000068 (BW/A06) Control Room Evac. / 8 X

interpret the following as they apply to the Control Room Evacuation: T-hot, T cold, and in-core temperatures 000069 (W/E14) Loss of CTMT Integrity! 5

074EA2.07 Ability to determine or 4.1/4.7

000074 (W/E06&E07) mad. Core Cooling / 4 X

interpret the following as they apply to a Inadequate Core Cooling: The difference between a LOCA and inadequate core cooling, from trends and indicators 000076 High Reactor Coolant Activity / 9

W/EO1 & E02 Rediagnosis & SI Termination / 3

W/E13 Steam Generator Over-pressure/4

W/E15 Containment Flooding! 5 (SRO)

X WE15EG2.4.18 Knowledge of the specific 3.3/4.0 bases for EOPs W!E16 High Containment Radiation /9

8W/AOl Plant Runback! 1

BW/A02&A03 Loss of NNI-XJY /7

BW/A04 Turbine Trip! 4

BW/A05 Emergency Diesel Actuation / 6

BW/A07 Flooding / 8

BW/E03 Inadequate Subcooling Margin /4

WEO3EG2.1.32 Ability to explain and 3.8/4.0 BW/E08; WIEO3 LOCA Cooldown

- Depress. / 4 X

apply system limits and precautions.

WEO9EKI.2 Knowledge of the operational

3.3/3.7 BW!E09; CE/Al 3; W/E09&El 0 Natural Circ. /4 X

implications of the following concepts as they apply to the (Natural Circulation Operations) Normal, abnormal and emergency operating procedures associated with (Natural Circulation Operations BW/E13&E14 EOP Rules and Enclosures

WEO8EA2.1 Ability to determine and CE/All; W/E08 RCS Overcooling

- PTS / 4 (SRO)

X interpret the following as they apply to 3.4/4.2 the (Pressurized Thermal Shock) Facility conditions and selection of appropriate procedures during abnormal and emergency operations.

CE/A16 Excess RCS Leakage / 2

CE/E09 Functional Recovery

( K/A Category Point Totals:

1 2

2j121lLGroup_Point Total:

9 K/A Category Point Totals: (SRO)

=

]2j2 Group Point Total:

4

ES-401, Rev. 9 4

Form ES-401-2

[401 PWR Examination Outline Form ES-401-2

Plant Systems

- her 2/Grouo jjRO / SRO)

System # / Name K

K K

K K

K A

A A

A G

K/A Topic(s)

IR 1234561234 003G2.2.42 Ability to recognize system 003 Reactor Coolant Pump X

parameters that are entry-level 3.9/46 conditions for Technical Specifications.

003K6.14 Knowledge of the effect of a 003 Reactor Coolant Pump X

loss or malfunction on the 2.6/2.9 following will have on the RCPS:

Starting requirements 004A2.22 Ability to (a) predict the 004 Chemical and Volume Control X

impacts of the following 3.2/3.1 malfunctions or operations on the CVCS; and (b) based on those predictions, use procedures to correct, control, or mitigate the consequences of those malfunctions or operations:

Mismatch of letdown and changing flows 005 Residual Heat Removal X

005K2.03 Knowledge of bus power 2.7/2.8 supplies to the following: RCS pressure boundary motor-operated valves 005 K3.07 Knowledge of the effect that 005 Residual Heat Removal X

a loss or malfunction of the RHRS will 3.2/3.6 have on the following: Refueling operations 006A1.07 Ability to predict andlor 006 Emergency Core Cooling X

monitor changes in parameters (to 3.3/3.6 prevent exceeding design limits) associated with operating the ECCS controls including: Pressure, high and low 006A2.10 Ability to (a) predict the 006 Emergency Core Cooling (SRO)

X impacts of the following malfunctions or operations on the ECCS; and (b) based on those predictions, use procedures to correct, control, or mitigate the consequences of those malfunctions or operations: Low boron concentration in SIS 006 Emergency Core Cooling X

006A4.04 Ability to manually operate 3.7/3.6 andlor monitor in the control room:

RHRS

007A1 01 Ability to predict andlor monit 007 Pressurizer Relief/Quench Tank X

changes in parameters (to prevent 2.9/3.1 exceeding design limits) associated wit operating the PRTS controls including:

Maintaining quench tank water level within limits 008 Component Cooling Water X

008K2.02 Knowledge of bus power 3.0/3.2 supplies to the following: CCW pump, including emergency backup

008K3.01 Knowledge of the effect that

008 Component Cooling Water X

a loss or malfunction of the CCWS will have on the following Loads cooled by CCWS

010K6.04 Knowledge of the effect of a

010 Pressurizer Pressure Control X

loss or malfunction of the following 2.9/3.2 will have on the PZR PCS: PRT

012A3.06 Ability to monitor automatic

012 Reactor Protection X

operation of the RPS, including: Trip logic

013K1.l8Knowledgeofthephysical

013 Engineered Safety Features X

connections and/or cause effect 3.7/4,1 Actuation relationships between the ESFAS and the following systems: Premature reset of ESF actuation

022A2.O3Ability to (a) predict the

022 Containment Cooling (SRO)

X impacts of the following malfunctions 2.6/3.0 or operations on the CCS; and (b) based on those predictions, use procedures to correct, control, or mitigate the consequences of those malfunctions or operations Fan motor thermal overload/high-speed operation

022A4.05 Ability to manually operate

022 Containment Cooling X

and/or monitor in the control room:

3.8/3.8 Containment readings of temperature, pressure, and humidity system 025 Ice Condenser N/A 026A4.01 Ability to manually operate

026 Containment Spray X

andlor monitor in the control room:

CSS controls 039K5.08 Knowledge of the operational

039 Main and Reheat Steam X

implications of the following concepts 3.6/3.6 as the apply to the MRSS: Effect of steam removal on reactivity

039A2.02 Ability to (a) predict the

039 Main and Reheat Steam (SRO)

X impacts of the following mal-functions 2.4/2.7 or operations on the MRSS; and (b) based on predictions, use procedures to

correct, control, or mitigate the consequences of those malfunctions or operations: Decrease in turbine load as it relates to steam escaping from relief valves

059A2.01 Ability to (a) predict the

059 Main Feedwater X

impacts of the following malfunctions 3.4/3.6 or operations on the MFW; and (b) based on those predictions, use procedures to correct, control, or mitigate the consequences of those malfunctions or operations: Feedwater actuation of AFW system 059 Main Feedwater X

059A3.04 Ability to monitor automatic 2.5/2.6 operation of the MFW, including:

Turbine driven feed pump

061K5.01 Knowledge of the operational

061 Auxiliary/Emergency Feedwater X

implications of the following concepts 3.6/3.9 as the apply to the AFW: Relationship between AFW flow and RCS heat transfer

061A2.04 Ability to (a) predict the

061 Auxiliary/Emergency Feedwater X

impacts of the following malfunctions 3.4/3.8 or operations on the AFW; and (b) based on those predictions, use procedures to correct, control, or mitigate the consequences of those malfunctions or operations: pump failure or improper operation

062K3.03 Knowledge of the effect that a 062 AC Electrical Distribution X

loss or malfunction of the ac distribution system will have on the following: DC system

063A1.01 Ability to predict andlor

063 DC Electrical Distribution X

monitor changes in parameters 2.5/3.3 associated with operating the DC electrical system controls including:

Battery capacity as it is affected by discharge rate

063K1.02 Knowledge of the physical

063 DC Electrical Distribution X

connections andlor cause-effect 2.7/3.2 relationships between the DC electrical system and the following systems: AC electrical system 064G2.4.34 Knowledge of RO tasks 064 Emergency Diesel Generator X

performed outside the main control 4.2/4.1 room during an emergency and the resultant operational effects.

073K5.02 Knowledge of the operational

073 Process Radiation Monitoring X

implications as they apply to concepts 2.5/3.0 as they apply to the PRM system:

Relationship between radiation intensity and exposure limits

076K4.06 Knowledge of SWS design

076 Service Water X

feature(s) andlor interlock(s) which 2.8/3.2 provide for the following: Service water train separation

076G2.4.47 Ability to diagnose and

076 Service Water (SRO)

X recognize trends in an accurate and 4.2/4.2 timely manner utilizing the appropriate control room reference material.

078G2.1.19 Ability to use plant

078 Instrument Air X

computers to evaluate system or 3.1/3.1 component status.

1 03K1.08 Knowledge of the physical

103 Containment X

connections andlor cause-effect 3638 relationships between the containment system and the following systems: SIS, including action of safety injection reset

103G2.2.36 Ability to analyze the effect

103 Containment (SRO)

X of maintenance activities, such as 3142 degraded power sources, on the status of limiting conditions for operations.

K/A Category Point Totals:

IT IjL 2

3 Group Point Total:

K/A Category Point Totals: (SRO)

=

=

I

=

=

2 Group Point Total:

5

ES-401, Rev. 9 5

Form ES4OI-2 ES-401 PWR Examination Outline Form ES-401-2 Plant Systems Tier 2/Group 2 (RO / SRO)

System # / Name K

K K

K K

K A

A A

A G

K/A Topic(s)

IR 1

23456 1

234 001 G2.2. 12 Knowledge of surveillance 001 Control Rod Drive (SRO)

X procedures.

3.7/4.1 002 Reactor Coolant X

002G2.2.40 Ability to apply Technical 3.4/3.7 Specifications for a system.

011 Pressurizer Level Control 014 Rod Position Indication X

014A4.01 Ability to manually operate 3.3/3.1 and/or monitor in the control room: Rod selection control 01 5A2.03 Ability to (a) predict the 015 Nuclear Instrumentation X

impacts of the following malfunctions or (SRO) operations on the NIS; and (b based on those predictions, use procedures to correct, control, or mitigate the consequences of those malfunctions or operations: Xenon oscillations 016 Non-nuclear Instrumentation 01 7K6.01 Knowledge of the effect of a 017 In-core Temperature Monitor X

loss or malfunction of the following ITM 2.7/3.0 system components: Sensors and detectors 027K2.O1 Knowledge of bus power 027 Containment Iodine Removal X

supplies to the following: Fans 3.1/3.4 028 Hydrogen Recombiner and Purge Control

029A3.01 Ability to monitor automatic 029 Containment Purge X

operation of the Containment Purge 3.8/4.0 System including: CPS isolation 033 Spent Fuel Pool Cooling

034K1.04 Knowledge of the physical 034 Fuel Handling Equipment X

connections and/or cause-effect 2.6/3.5 (SRO) relationships between the Fuel Handling System and the following systems: NIS 034K4.03 Knowledge of design 034 Fuel Handling Equipment X

feature(s) and/or interlock(s) 2.6/3.3 which provide for the following:

Overload protection 035 Steam Generator 041 Steam Dump/Turbine Bypass Control

045 Main Turbine Generator 055 Condenser Air Removal 056 Condensate O68LiguidRadwaste

071A1.06 Ability to predict and!or 071 Waste Gas Disposal X

monitor changes in parameters(to 2.5/2.8 prevent exceeding design limits) associated with Waste Gas Disposal System operating the controls including: Ventilation system 072K3.02 Knowledge of the effect that a 072 Area Radiation Monitoring X

loss or malfunction of the ARM system 3.1/3.5 will have on the following: Fuel handling operations 075A2.03 Ability to (a) predict the 075 Circulating Water X

impacts of the following malfunctions 2.5/2.7 or operations on the circulating water system; and (b) based on those predictions, use procedures to correct, control, or mitigate the consequences of those malfunctions or operations:

Safety features and relationship between condenser vacuum, turbine trip, and steam dump 079 Station Air 086K5.04 Knowledge of the operational 086 Fire Protection X

implication of the following concepts as 2.9/3.5 they apply to the Fire Protection System: Hazards to personnel as a result of fire type and methods of protection K/A Category Point Totals:

C 1

1 1

1 1

1 1

1 1

1] Group Point Total:

10 K/A Category Point Totals: (SRO) 1

[

1 Group Point Total:

J]

Facility:

Harris Date of Exam:

2011 RO SRO-Only Category K/A #

Topic JR Q#

JR Q#

Ability to coordinate personnel activities outside 2.1.8 the control room.

3.4 4.1 Knowledge of industrial safety procedures (such as rotating equipment, electrical, high 3.4 3.6 Conduct of 2.1.26 temperature, high pressure, caustic, chlorine, Operations oxygen and hydrogen).

2 1 35 Knowledge of the fuel-handling responsibilities of SROs. (SRO)

Subtotal 2

1 Knowledge of the process for controlling 2.2.14 equipment configuration or status. (SRO) 43 2.2.20 Knowledge of the process for managing 2.6 3.8 troubleshooting activities.

2.

Knowledge of conditions and limitations in the 2.2.38 Equipment Control facility license. (SRO) 2.2.42 Ability to recognize system parameters that are 3.9 4.6 entry-level conditions for Technical Specifications.

Subtotal 2

2 2 3 4 Knowledge of radiation exposure limits under 3.2 3.7 normal or emergency conditions Ability to use radiation monitoring systems, such as fixed radiation monitors and alarms, portable 2.9 2.3.5 survey instruments, personnel monitoring equipment, etc. (SRO)

Ability to comply with radiation work permit 2.3.7 requirements during normal or abnormal 3.6 conditions. (SRO) 3.

Knowledge of radiological safety procedures Radiation Control pertaining to licensed operator duties, such as 2.3.13 response to radiation monitor alarms, containment 3.4 3.8 entry requirements, fuel handling responsibilities, access to locked high-radiation areas, aligning filters, etc.

Knowledge of radiation or contamination hazards 2 3 14 that may arise during normal, abnormal, or 3.4 3.8 emergency conditions or activities.

Subtotal 3

2 2.4.12 Knowledge of general operating crew 40 4.3 responsibilities during emergency operations.

2.4.22 Knowledge of the bases for prioritizing safety 36 4.4 functions during abnormallemergency operations.

2.4.27 4.

Knowledge of afire in the planr procedures. (SRO) 3.9 Emergency 2.4.17 Knowledge of EOP terms and definitions. (SRO) 4.3 Procedures / Plan Ability to prioritize and interpret the significance of 2.4.45 each annunciator or alarm.

4.1 4.3 Subtotal 3

2 Tier 3 Point Total 10 7

o1ztW1 ES-301 Administrative Topics Outline Form ES-301-l Facility: Harris Nuclear Plant Date of Examination: July 11 2011 Examination Level:

RD SRO Operating Test Number:

05000400/2011301 Administrative Topic Type Describe activity to be performed (see Note)

Code*

Determine Rod Height Misalignment Using Thermocouples (JPM CR-I 39) Common Conduct of Operations P, R K/A G2.1.7 2011 NRC_RO Al-I Determine the Target Rod Height and the Boron Concentration Change Required for a Rapid Power Conduct of Operations M, R Reduction lAW AOP-038 K/A G2.1.25 2011 NRC RO Al-2 Review the Completed OST for Auxiliary Feedwater Equipment Control Pump lB-SB N, R (JPM ADM-103)

K/A G2.2.12 2011 NRC RO A2 Using Survey Maps, Simplified Drawings, Plant Maps and Valve Lists, determine stay times while performing Radiation Control M, R a clearance activity.

(JPM ADM-l00) Common K/A G2.3.4 2011 NRC ROA3 NOT SELECTED FOR RD Emergency Procedures/Plan N/A 2011 NRC RO A4 NOTE:

All items (5 total) are required for SROs. RD applicants require only 4 items unless they are retaking only the administrative topics, when all 5 are required.

  • Type Codes & Criteria:

(C)ontrol room, (S)imulator, or Class(R)oom (D)irect from bank ( 3 for ROs; 4 for SROs & RO retakes)

(0)

(N)ew or (M)odified from bank ( 1)

(3)

(P)revious 2 exams ( 1; randomly selected)

(1)

2011 NRC RO Admin JPM Summary 2011 NRC RO Al-I

- Determine Rod Misalignment Using Thermocouples Previous

- 2009A NRC Exam JPM *randomly selected from bank K/A G2. 1.7 Ability to evaluate plant performance and make operationaljudgments based on operating characteristics, reactor behavior, and instrument interpretation.

(CFR: 41.5 / 43.5 / 45.12/45.13) RO 4.4 SRO 4.7 The plant is at 90% power with a load decrease in progress when a control rod is observed indicating 12 steps higher than group demand. The candidate must perform Attachment 2 of AOP-001, Malfunction of Rod Control and Indication System, to calculate the temperature difference between the affected thermocouple and its symmetric thermocouples.

NOTE: Two thermocouple temperatures were changed with the resulting calculation now indicating a difference of greater than 10°F, indicating that the rod is misaligned. The 2009a JPM thermocouple temperatures resulted in a calculation of <10°F. During the 2009a exam the <10°F difference resulted was a rod position indication problem. For the 2011 exam the temperature difference of >10°F will have a concluding result of a rod misalignment.

2011 NRC RO A1-2

- Determine the Target Rod Height and the Boron Concentration Change Required for a Rapid Power Reduction lAW AOP-038 MODIFIED K/A G2. 1.25 Ability to interpret reference materials, such as graphs, curves, tables, etc.

(CFR: 41.10 / 43.5 / 45.12) RO 3.9 SRO 4.2 With plant conditions requiring a rapid power reduction to 65% power the candidate will be required to determine the target rod height, the time in core life and the amount of boric acid required for the power reduction.

This JPM was modified by changing the initial power level conditions and final power level.

2011 NRC RO A2

- Review the Completed OST for Auxiliary Feedwater Pump 1 B-SB

- NEW (JPM ADM-103)

K/A G2.2. 12 Knowledge of surveillance procedures.

(CFR: 41.10/45.13) RO 3.7 SRO 4.1 The candidate will be supplied a completed copy of OST-1 076, Auxiliary Feedwater Pump lB-SB Operability Test Quarterly Interval Modes 1-4 and be assigned the task of performing a peer check of the procedure prior to approval from the CRS.

2

2011 NRC RO Admin JPM Summary (continued) 2011 NRC RO A3 (Common)

- Using Survey Maps, Simplified Drawings, Plant Maps and valve lists, determine stay times while performing a clearance activity. MODIFIED K/A G2. 3.4 - Knowledge of radiation exposure limits under normal or emergency conditions.

(CFR: 41.12/43.4/45.10) RO 3.2 SRO 3.7 The candidate will be supplied a survey map of a location in the RAB and a clearance mission to complete in this radioactive area. The location also contains one or more hot spots. They must determine the individual stay times for two Auxiliary Operators (AO) without exceeding the annual administrative dose limits. They will be provided Survey Maps, Simplified plant drawings to locate valves, Plant Maps of the area and a plant valve list to determine the location of the valves they will be hanging a clearance on. The given information will supply the accumulated annual whole body doses for the two AOs, one of which recently worked for another utility. They must perform their calculations based on Progress Energy Administrative Dose Limits.

This JPM was modified by changing the location of the clearance and values of radiation areas.

2011 NRC RO A4 Not selected 3

ES-301 Administrative Topics Outline Form ES-301-1 Facility: Harris Nuclear Plant Date of Examination: July II 2011 Examination Level:

RO SRO I Operating Test Number:

05000400/2011301 Administrative Topic Type Describe activity to be performed (see Note)

Code*

Determine Rod Height Misalignment Using Conduct of Operations Thermocouples (JPM CR-I 39) Common P, R K/A G2.1.7 2011 NRC SRO Al-I Determine Subcooling with the Subcooling Margin Monitor Unavailable Conduct of Operations (JPM ADM-031)

M,R K/AG2.1.23 2011 NRC SROA1-2 Review (for approval) a completed surveillance D, R procedure for PORV block valves.

Equipment Control (JPM ADM-035 SRO)

K/A G2.2.12 2011 NRC SROA2 Using Survey Maps, Simplified Drawings, Plant Maps M, R and Valve Lists, determine stay times while performing Radiation Control a clearance activity.

(JPM ADM-100) Common K/A G2.3.4 2011 NRC SROA3 N R Given a Set of Plant Conditions Classify An Event.

K/A G2.4.41 Emergency Procedures/Plan 2011 NRC SROA4 NOTE:

All items (5 total) are required for SROs. RO applicants require only 4 items unless they are retaking only the administrative topics, when all 5 are required.

  • Type Codes & Criteria:

(C)ontrol room, (S)imulator, or Class(R)oom (D)irect from bank ( 3 for ROs; 4 for SROs & RO retakes)

(1)

(N)ew or (M)odified from bank ( 1)

(3)

(P)revious 2 exams ( 1; randomly selected)

(1)

I

2011 NRC SROAdminJPM Summary 2011 NRC SRO Al-I

- Determine Rod Misalignment Using Thermocouples Previous

- 2009A NRC Exam JPM *randomly selected from bank K/A G2. 1.7 Ability to evaluate plant performance and make operationaljudgments based on operating characteristics, reactor behavior and instrument interpretation.

(CFR: 41.5 / 43.5 / 45.12 / 45.13) RO 4.4 SRO 4.7 The plant is at 90% power with a load decrease in progress when a control rod is observed indicating 12 steps higher than group demand. The candidate must perform Attachment 2 of AOP-001, Malfunction of Rod Control and Indication System, to calculate the temperature difference between the affected thermocouple and its symmetric thermocouples.

NOTE: Two thermocouple temperatures were changed with the resulting calculation now indicating a difference of greater than 10°F, indicating that the rod is misaligned. The 2009a JPM thermocouple temperatures resulted in a calculation of <10°F. With <10°F difference the result was a rod position indication problem. With the temperature difference of >10°F the result is a rod misalignment.

In the current JPM the SRO will need to determine Tech Spec requirements for a rod misalignment.

2011 NRC SRO A1-2

- Determine Subcooling with the Subcooling Margin Monitor Unavailable (JPM ADM-031) Bank

- MODIFIED K/A G2. 1.23-Ability to perform specific system and integrated plant procedures during all modes ofplant operation.

(CFR: 41.10 / 43.5 / 45.2/45.6) RO 4.3 SRO 4.4 The applicant will be informed that a Small Break LOCA has occurred with SI actuated.

They will be provided with copies of the EOP Users Guide and multiple plant parameters.

They will be required to determine the RCS Subcooling margin lAW the EOP Users Guide directions.

This JPM was modified by changing the initial conditions to where the Containment pressure will be > 3 psig requiring the candidate to use adverse Containment values.

In addition to this change the ERFIS computer will not be available. These two changes will require using different indicators and the results will be completely different values.

2011 NRC SRO A2

- Review (for approval) a completed surveillance procedure for PORV block valves. (JPM ADM-035 SRO) Direct K/A G2. 2.12-Knowledge of surveillance procedures.

(CFR:41.10/45.13)R03.7 SRO4.1 The applicant will be provided with a handout of a completed copy of a PORV Block Valve full stroke quarterly surveillance. The procedure contains three (3) errors that the candidate must identify.

2

2011 NRC SRO Admin JPM Summary (continued) 2011 NRC SRO A3 (Common)

- Using Survey Maps, Simplified Drawings, Plant Maps and valve lists, determine stay times while performing a clearance activity.

(2009B NRC Admin JPM)

- MODIFIED K/A G2. 3.4

- Knowledge of radiation exposure limits under normal or emergency conditions.

(CFR: 41.12/43.4/45.10) RD 3.2 SRO 3.7 The applicant will be supplied a survey map of a location in the RAB and a clearance mission to complete in this radioactive area. The location also contains one or more hot spots. They must determine the individual stay times for two Auxiliary Operators (AO) without exceeding the annual administrative dose limits. They will be provided Survey Maps, Simplified plant drawings to locate valves, Plant Maps of the area and a plant valve list to determine the location of the valves they will be hanging a clearance on. The given information will supply the accumulated annual whole body doses for the two AOs, one of which recently worked for another utility. They must perform their calculations based on Progress Energy Administrative Dose Limits.

This JPM was modified by changing the location of the clearance and radiation area intensities.

2011 NRC SRO A4

- Classify an Event (NEW)

K/A G2.4.41 Knowledge of the emergency action level thresholds and classifications (CFR: 41.10/43.5/45.1 1) RD 2.9 SRO 4.6 Given a set of initial conditions and the EAL Flow Path, the candidate must classify the appropriate Emergency Action Level for the event in progress.

3

Dp{

Control Roomlln-Plant Systems Outline Facility:

Harris Nuclear Plant Date of Examination:

07/11/2011 Exam Level: RD SRO-l SRO-U (bold)

Operating Test No.: 05000400/2011301 Control Room Systems@ (8 for RO); (7 for S RD-I); (2 or 3 for SRO-U, including I ESF - bold)

System I JPM Title Type Code*

Safety Function a.

Continuous Rod Withdrawl of a Control Bank - Pull to A, M, L, S I

POAH I Take Corrective Actions lAW AOP-OO1 (AOP-OO1) (JPM-CR-048)

K/A APE 001 AA2.03 b.

Loss of Seal Injection To The RCPs - take corrective actions lAW AOP-018 A, N, EN, S 2

(AOP-0I8) (NEW JPM-CR-245)

K/A APE 015/017 AA2.10 c.

SGTR Without Pressurizer Pressure Control A, D, S 3

(EOP-EPP-022) (JPM-CR-1 50)

K/A G2.1.20 d.

Loss of RCS Inventory While on RHR MODE 5 A, D, EN, S 4P (AOP-020) (JPM-CR-60)

K/A 005 A4.01 e.

Using ESW System As A Backup Source Of Water To AFW P, S 4S (PATH-i and OP-i 37) (JPM-CR-107)

K/A 054 AAI.01 f.

Reduce Containment Spray Flow M, EN, 5 5

(EOP-EPP-Oi 2) (J PM-CR-233) RO ONLY K/A 026 A4.01 g.

Start a Emergency Diesel Generator for Testing A, D, EN, S 6

(OP-155) (JPM-CR-007)

K/A 064 A4.06 h.

Respond to a Rupture in the Instrument Air Header at A, D, S 8

50% power (AOP-01 7) (JPM-CR-234)

K/A APE 065 AA2.06 ES-301 Form ES-301-2 1

In-Plant Systems@ (3 for RO); (3 for SRO-l); (3 or 2 for SRO-U

- BOLD) i.

Reset the Turbine Driven AFW Pump Mechanical D, E, R 4S Overspeed (pump tripped on start)

(OP-I 37) (JPM-IP-OOI)

K/A 061 K4.07 j.

Align the Train A Battery Charger to the Alternate E, N 6

Power Supply K/A APE 058 AAI.01 k.

ATWS Locally Trip the Reactor D, E 7

(FRP-S.1) (JPM-IP-1 16)

K/A 029 EAI.11 All RO and SRO-l control room (and in-plant) systems must be different and serve different safety functions; all 5 SRO-U systems must serve different safety functions; in-plant systems and functions may overlap those tested in the control room.

  • Type Codes Criteria for RO / SRO-l I SRO-U (A)lternate path 4-6 / 4-6 / 2-3 (6, 6, 3)

(C)ontrol room (D)irect from bank 9/

8 I 4

(6, 6, 2)

(E)mergency or abnormal in-plant 1 /

1 /

1 (3, 3, 2)

(EN)gineeredsafetyfeature

- I

/ 1 (4,3,1)

(L)ow-PowerlShutdown 1 / 1 I 1 (1,1,1)

(N)ew or (M)odified from bank including 1(A) 2 I 2 I 1

(4, 3, 3)

(P)revious 2 exams 3 I 3 /

2 (1, 1, 0)

(R)CA 1I1I1 (1,1,1)

(S)imulator 2

2011 NRC Control Room/In-Plant JPM Summary JPM a Continuous Rod Withdrawl of a Control Bank (Pull to POAH I Take Corrective Actions lAW AOP-0O1 (JPM-CR-048) SRO Upgrade K/A APE 001 AA2. 03-Ability to determine and interpret the following as they apply to the Continuous Rod Withdrawal: Proper actions to be taken if automatic safety functions have not taken place (CFR: 43.5/45.13) RO 4.5 SRO 4.8 The previous crew was performing a Reactor Startup and was taking critical data at 1x10 8

amps when the RO became ill and needed to be relieved. The candidate will be the relief RO and be directed to continue with the Reactor Startup by increasing Reactor power to the Point Of Adding Heat (1-3% power). The candidate will withdraw control rods in manual lAW OP-i 04, Rod Control System and GP-004, Reactor Startup (Mode 3 to Mode 2) to raise Reactor power while ensuring that a steady state stable Start Up Rate does not exceed 1 DPM. While the control rods are being withdrawn a malfunction will cause the control rods to continue to withdraw when the rods no longer have a demand signal to withdraw. After the candidate releases the rod control out lever the rods will continue to withdraw at 48 steps per minute. The candidate will be expected to analyze the malfunction and determine that entry into AOP-O01, Malfunction of Rod Control and Indication System is met. They will then perform immediate actions of AOP-OOi and manually trip the Reactor. The JPM is complete after the candidate verifies that the Reactor is tripped lAW PATH-I step 1.

JPM b Loss of Seal Injection To The RCPs (ASI pump running, align and start standby CSIP)

(NEW JPM-CR-245) SRO Upgrade K/A APE 015/017AA2. 10 Ability to determine and interpret the following as they apply to the Reactor Coolant Pump Malfunctions (Loss of RC Flow): When to secure RCPs on loss of cooling or seal injection (CFR43.5/45.13) RO 3.7/SRO 3.7 The candidate will assume the Operator at the Controls (OAC) responsibilities with the plant operating at 100% power and the B Charging Safety Injection Pump (CSIP) under clearance for seal repairs. Preparations to place the standby CSIP in service are under way but have not been completed. After taking the watch the A CSIP will trip requiring the candidate to identify that AOP-0I 8, Reactor Coolant Pump Abnormal Conditions, entry conditions are met. The candidate will then perform the immediate action of Check any CSIP running answer NO and perform the RNO action of isolating letdown. After completing the immediate action the candidate will obtain a copy of AOP-0i 8 and begin the actions of the AOP. Without any CSIP running a loss of seal flow to the RCPs is occurring.

A new CVCS positive displacement pump named the Alternate Seal Injection pump (ASI pump) will auto start 2 minute and 45 seconds after 2 out of 3 flow switches detect RCP seal flows <4.0 gpm. AOP-01 8 directs to the operator to trip the Reactor if the ASI pump is operating. Since the ASI pump suction tank boron concentration is required to be 3800

4200 ppm any time the ASI pump is in operation a large amount of negative reactivity will be added to the RCS. The candidate is expected to carry out the RNO actions of the procedure and perform a manual Reactor trip. They will then perform the immediate actions of PATH-i. When the immediate actions are completed they will be directed to continue with AOP-018 actions to isolate the Seal Return flowpat. The JPM is complete when RCP seal water return valves are isolated.

3

2011 NRC Control Roomlln-Plant JPM Summary JPM c SGTR Without Pressurizer Pressure Control (JPM-CR-1 50)

K/A G2. 1.20 - Ability to interpret and execute procedure steps.

(CFR: 41.10/43.5/45.12) RO 4.6/SRO 4.6 The candidate will be informed that EOP-EPP-022 has just been entered after a transition from PATH-2. The plant conditions are: a SGTR occurred on the A SG, offsite power has been lost, and neither the PZR PORVs or PZR Auxiliary spray is functional. The SG tube rupture will be increasing A SG level as the candidate proceeds through EPP-022. Initially A SG level will be < 78% requiring the candidate to proceed to step 2 of the procedure.

Continuing through the procedure the candidate will get to step 5 to check PZR level> 10%

answer NO and return to step 1. By this time the A SG level will now be > 78% requiring the candidate to use the RNO step to go to step 6 and terminate SI. The JPM is complete after the candidate has shut the BIT outlet valves 1SI-3 and I Sl-4 and verified Cold Leg and Hot Leg Injection valves are shut.

JPM d Loss of RCS Inventory While on RHR MODE 5 (JPM-CR-60)

K/A 005 A4.01 Ability to manually operate and/or monitor in the control room: Controls and indication for RHR pumps (CFR: 41.7/45.5 to 45.8) RO 3.6/SRO 3.4 The candidate will be assigned the role of OAC and be directed to maintain current plant conditions of: the plant in Mode 5 with Containment integrity established, on RHR and a bubble in the PZR, RCS temperature stable at 140°F and all RCPs operating. Soon after assuming the watch a RCS leak will develop requiring the candidate to enter AOP-020, Loss of RCS Inventory or RHR While Shutdown. The candidate will obtain a copy of AOP-020 and perform steps to attempt leak isolation. When unable to isolate the leak the procedure directions are to isolate RHR and secure both RHR pumps (this will isolate the leak). The JPM is complete after RHR is isolated and both A and B RHR pump is secured.

JPM e Using ESW. System As A Backup Source of Water To AFW (JPM-CR-1 07)

PREVIOUS 2009a NRC Exam K/A 054 AA 1.01 Ability to operate and/ or monitor the following as they apply to the Loss of Main Feedwater AFW controls, including the use of alternate AFW sources (CFR 41.7/45.5/45.6) RO 4.5/SRO 4.4 Following a LOCA the operator is informed that a leak developed in the Condensate Storage Tank (CST). The CST level has decreased to < 10%. The candidate is directed to supply ESW from the A Header to both the A AFW Pump and the Turbine Driven AFW pumps.

This will require shutting down the B MDAFW Pump and A Train of Containment Fan Coolers in addition to the ESW valve alignment.

4

2011 NRC Control Room!ln-Plant JPM Summary JPM f Reduce Containment Spray Flow (JPM-CR-233) RO ONLY K/A 026 A4. 01 Ability to manually operate and/or monitor in the control room: CSS controls (CFR: 41.7/45.5 to 45.8) RO 4.5 SRO 4.3 The candidate will be assigned the OAC position with a large break LOCA in progress.

Containment pressure has exceeded 10 psig and the crew transitioned to EPP-01 2, Loss of Emergency Coolant Recirculation, and step 4 has been completed. The candidate will be instructed to proceed in EPP-012 starting with step 5. They will be expected to determine the number of Containment Spray pumps required to be in operation based on Containment Pressure, Containment fan coolers in operation and RWST level. They should determine that both Containment Spray Pumps can be secured, stop both pumps and shut the associated pump discharge valves. The candidate should also determine that RWST makeup is required based on current level.

JPM g Start EDG A SA From MCB for Testing (JPM-CR-007) Alternate Path and Engineered Safety Feature K/A 064 A4. 06 Ability to manually operate and/or monitor in the control room: Manual start; loading, and stopping of the ED/G (CFR: 41.7/45.5 to 45.8) RO 3.9 SRO 3.9 With the unit operating at 100% power the candidate will be directed to start the IA-SA EDG from the main control board in accordance with section 5.1 of OP-I 55. After verifying the EDG is ready to start and contacting and directing the local operator to perform steps prior to starting the EDG, the applicant starts the EDG and a short time after the start the AO reports that the EDG crank case relief is lifting and oil is spraying on the side of the diesel.

After the report is made the Simulator Operator will start a trigger that will trip the EDG in I minute. The applicant is expected to immediately shut down the diesel in accordance with P

& L 2 of OP-I 55.

If the applicant reports the crank case relief to the CRS the response will be to follow your procedures. The EDG will be inoperable after this failure and the SRO applicant can provide TS and LCO associated with the failure.

JPM h Respond to a Rupture in the Instrument Air Header at 50% power (JPM-CR-234)

Alternate Path SRO Upgrade K/A APE 065 AA2. 06 Ability to determine and interpret the following as they apply to the Loss of Instrument Air: When to trip reactor if instrument air pressure is decreasing (CFR: 43.5/45.13) RO 3.6 SRO 4.2 The candidate will be assigned the OAC position and be directed to maintain current plant conditions of steady state -50% power. The plant is on hold for chemistry concerns. Soon after taking the watch an Instrument Air leak will develop. The candidate will be expected to respond to the low pressure annunciators and enter AOP-0l 7. Air pressure will decrease requiring a manual Reactor Trip. The candidate will be expected to perform the immediate actions of PATH-I then be directed to continue with AOP-0I7. They will have to contact Auxiliary Operators to vent and depressurize the remaining air from the system. Continuing with the procedure requires the candidate to locate and place multiple MCB controls to manual and zero demand.

5

2011 NRC Control Roomlln-Plant JPM Summary JPM i Reset the Turbine Driven AFW Pump Mechanical Overspeed - pump tripped on start (JPM-IP-O01) SRO Upgrade K/A 061 K4. 07 Knowledge of AFW design feature(s) and/or interlock(s) which provide for the following:

Turbine trip, including overspeed (CFR: 41.7) RO 3.1 SRO 3.3 NOTE: This JPM is inside the RCA The candidate will be informed that the plant has tripped from 100% power. The Turbine Driven AFW pump started and has tripped on overspeed. The pump is needed for plant cooldown efforts. The cause of the overspeed trip has been identified anti corrected by Maintenance.

The CRS has directed the candidate to reset the Turbine Driven AFW mechanical overspeed trip linkage.

1 MS-70 and 1 MS-72 (steam supply valves to the TDAFW pump) are indicating shut from the MCB. The CRS also notifies the candidate that the Trip and Throftle Valve will be reopened from the Control Room.

JPM I Align a Train A battery Charger to the alternate Power Supply NEW SRO Upgrade K/A APE 058 AA 1.01 Ability to operate and / or monitor the following as they apply to the Loss of DC Power: Cross-tie of the affected dc bus with the alternate supply (CFR 41.7/45.5/45.6) RO 3.4 SRO 3.5 The candidate will be informed that the plant is in Mode 3 following a Reactor Trip from a Loss of Off-Site power and failure of both Emergency Diesel Generators to energize their respective Emergency Buses. The Crew will be implementing EPP-001, Loss of AC Power to 1A-SA and lB-SB Buses, they have verified that the Dedicated Shutdown Diesel Generator has started, loaded and is now supplying 1 D23 bus. The CRS will be directing the candidate to align the IA-SA battery Charger to the alternate Power Supply lAW EOP-001 step 22 using OP-i 56.01, AC Electrical Distribution, Section 8.15 with initial conditions met.

NOTE: This is a new component was installed during the RFO-i 7 refueling outage.

JPM k ATWS Locally Trip the Reactor (FRP-S. 1) (JPM-lP-i 16)

K/A 029 EAI. 11 Ability to operate and monitor the following as they apply to a ATWS: Manual opening of the CRDS breakers (CFR4I.7/45.5/45.6)R03.9 SRO4.1 The candidate will be informed that a Reactor trip signal has been received, but the Reactor did not trip. The control room is implementing FRP-S.1. They will be directed to respond as if they were the Turbine Building operator and had responded to a page from the Main Control Room.

6