FEMA - Submittal of Final Report for Radiological Emergency Preparedness Exercise for Three Mile Island Generating Station, Held on April 12, 2011
ML11216A053
Person / Time
Site: Crane  
Issue date: 07/28/2011
From: Tierney M
US Dept of Homeland Security, Federal Emergency Management Agency
To:
Document Control Desk, Office of Nuclear Reactor Regulation
References
Download: ML11216A053 (188)


Text

U.S. Department of Homeland Security Region III One Independence Mall, Sixth Floor 615 Chestnut Street Philadelphia, PA 19106-4404 ND SFMA IJUL 2 8 2011 NRC Headquarters' Document Control Desk U. S. Nuclear Regulatory Commission Washington, D.C. 20555-0001 To whom it may concern:

Enclosed is the final After Action Report/Improvement Plan for the Three Mile Island (TMI) Nuclear Generating Station Radiological Emergency Preparedness (REP) Exercise that was held on April 12, 2011.

There were no deficiencies identified during the exercise. Nine Areas Requiring Corrective Action (ARCAs) were identified; four were immediately re-demonstrated successfully and five others were re-demonstrated successfully on April 29, and May 9, 2011. One ARCA from a previous exercise was successfully re-demonstrated on May 2, 2011. Two new planning issues were identified and have been resolved.

Based on the review of the offsite radiological emergency response plans and procedures submitted, FEMA Region III has determined they are adequate and there is reasonable assurance they can be implemented, as demonstrated during the TMI REP Exercise.

If you have any questions, please contact Darrell Hammons at (215) 931-5546.

Sincerely, aryAnn Tierney Regional Administrator Enclosure www.fema.gov

Three Mile Island Nuclear Generating Station After Action Report/

Improvement Plan Exercise Date - April 12, 2011 Radiological Emergency Preparedness (REP) Program

~ FEMA Published July 27, 2011

a Unclassified Radiological Emergency Preparedness Program (REP)

Three Mile Island Nuclear Generating Station After Action Report/Improvement Plan 6

This page is intentionally blank.

0 S

Unclassified Radiological Emergency Preparedness Program (REP)

After Action Report/Improvement Plan Three Mile Island Nuclear Generating Station Three Mile Island Nuclear Generating Station After Action Report/Improvement Plan Published July 27, 2011 Contents Executive Summary 9

Section 1: Exercise Overview 14 1.1 Exercise Details 14 1.2 Exercise Planning Team Leadership 14 1.3 Participating Organizations 16 Section 2: Exercise Design Summary 21 2.1 Exercise Purpose and Design 21 2.2 Exercise Objectives, Capabilities and Activities 22 2.3 Scenario Summary 23 Section 3: Analysis of Capabilities 25 3.1 Exercise Evaluation and Results 25 3.2 Summary Results of Exercise Evaluation 25 3.3 Criteria Evaluation Summaries 39 3.3.1 Pennsylvania Jurisdictions 39 3.3.1.1 Pennsylvania Emergency Operations Center 39 3.3.1.2 Pennsylvania Joint Information Center 39 3.3.1.3 Pennsylvania Accident Assessment Center, State 39 Emergency Operations Center-Bureau of Radiation Protection 3.3.1.4 Pennsylvania State Traffic and Access Control 40 Points, State Police Barracks Harrisburg 3.3.2 Risk Jurisdictions 40 3.3.2.1 Cumberland County Emergency Operations Center 40 3.3.2.2 Cumberland County Emergency Worker Monitoring 40 and Decontamination Station, West Shore Fire Station #2, Lemoyne 3.3.2.3 Cumberland County Reception Center, Big Spring 41 High School 1

Unclassified Radiological Emergency Preparedness Program (REP)

After Action Report/Improvement Plan Three Mile Island Nuclear Generating Station 3.3.2.4 Cumberland County Monitoring and 41 Decontamination Center, Big Spring High School 3.3.2.5 Cumberland County, New Cumberland Borough 41 Emergency Operations Center 3.3.2.6 Cumberland County, New Cumberland Borough 41 Back-up Route Alerting 3.3.2.7 Dauphin County Emergency Operations Center 42 3.3.2.8 Dauphin County Emergency Worker Monitoring and 42 Decontamination Station, Harrisburg Area Community College 3.3.2.9 Dauphin County Mass Care Center, Lenkerville 42 Elementary School 3.3.2.10 Dauphin County Mass Care Center, Halifax Area 43 High School 3.3.2111 Dauphin County, Harrisburg City Emergency 43 Operations Center 3.3.2.12 Dauphin County, Highspire Borough Emergency 43 Operations Center 3.3.2.13 Dauphin County, Highspire Back-up Route Alerting 43 3.3.2.14 Dauphin County, Londonderry Township 44 Emergency Operations Center 3.3.2.15 Dauphin County, Paxtang Borough Emergency 45 Operations Center 3.3.2.16 Dauphin County, LowerPaxton Township 45 Emergency Operations Center 3.3.2.17 Dauphin County, South Hanover Township 46 Emergency Operations Center 3.3.2.18 Lancaster County Emergency Operations Center 46 3.3.2.19 Lancaster County Emergency Worker Monitoring 47 and Decontamination Station, Mount Joy Fire Department 3.3.2.20 Lancaster County Mass Care Center Conestoga 48 Valley High School 3.3.2.21 Lancaster County Mass Care Center, Conestoga 48 Valley Middle School 3.3.2.22 Lancaster County Reception Center, Park City Mall 48 3.3.2.23 Lancaster County Monitoring and Decontamination 49 Center, Manheim Township School Complex 3.3.2.24 Lancaster County Mass Care Center,Cocalico 49 Middle School 2

0

Unclassified Radiological Emergency Preparedness Program (REP)

After Action Report/Improvement Plan Three Mile Island Nuclear Generating Station 3.3.2.25 Lancaster County, Cocalico High School,Mass Care 49 Center 3.3.2.26 Lancaster County Mass Care Center, Manheim 49 Township Middle School 3.3.2.27 Lancaster County Mass Care Center, Warwick High 50 School 3.3.2.28 Lancaster County Mass Care Center, Warwick 50 Middle School 3.3.2.29 Lancaster County, Conoy Township Emergency 50 Operations Center 3.3.2.30.Lancaster County, Conoy Township Back-Up Route 51 Alerting 3.3.2.31 Lancaster County, East Donegal Township 52 Emergency Operation Center 3.3.2.32 Lancaster County, East Donegal Township Back-up 52 Route Alerting 3.3.2.33 Lancaster County, Elizabethtown Borough/West 52 Donegal Township/Mount.Joy Township Emergency Operations Center 3.3.2.34 Lancaster County, Elizabethtown Borough Traffic 52 and Access Control*

3.3.2.35 Lancaster County, Susquehanna Regional Police 53 Department Traffic and Access Control 3.3.2.36 Lebanon County Emergency Operations Center 53 3.3.2.37 Lebanon County Emergency Worker Monitoring and 53 Decontamination Station, Annville Union Hose Fire Department 3.3.2.38 Lebanon County Reception Center, Lebanon County 55 Career and Technological Center 3.3.2.39 Lebanon-County Monitoring and Decontamination 55 Center, Lebanon County Career and Technological Center 3.3.2.40 Lebanon County Mass Care Center, Northern 56 Lebanon High School 3.3.2.41 Lebanon County, South Londonderry Township 56 Emergency Operations Center 3.3.2.42 Lebanon County, South Londonderry Township, 56 Back-Up Route Alerting 3.3.2.43 Lebanon County, South Londonderry Township 58 Traffic and Access Control 3

Unclassified Radiological Emergency Preparedness Program (REP)

After Action Report/Improvement Plan Three Mile Island Nuclear Generating Station 3.3.2.44 York County Emergency Operation Center 58 3.3.2.45 York County Emergency Worker Monitoring and 59 Decontamination Station, Monaghan Fire Department 3.3.2.46 York County Reception Center, Southern. School 59 Complex 3.3.2.47 York County Monitoring and Decontamination 59 Center, Southern School Complex High School 3.3.2.48 York County Mass Care Center, Southern School 59 Complex 3.3.2.49 York County, Dover Township Emergency 60 Operations Center 3.3.2.50 York County, Lewisbury Borough/Newberry 60 Township Emergency Operations Center 3.3.2.51 York County, Newberry Township Back-up Route 62 Alerting 3.3.2.52 York County, Manchester Township Emergency 62 Operations Center 3.3.2.53 York County, Northeast Area Emergency Operations 62 Center (Mount Wolf, Manchester Borough, E Manchester Township) 3.3.2.54 Franklin County Mass Care Center, Faust Junior 63 High School 3.3.2.55 Dauphin County, Capital Area Intermediate Unit, 63 Administration Building 3.3.2.56 Dauphin County, Capital Area Intermediate Unit, 63 Capital Area School for the Arts 3.3.2.57 Dauphin County, Central Dauphin School District 63 3.3.2.58 Dauphin County, Central Dauphin School District, 64 Central Dauphin East High School 3.3.2.59 Dauphin County, Central Dauphin School District, 64 Swatara Middle School 3.3.2.60 Dauphin County, Central Dauphin School District, 64 Tri Community Elementary School 3.3.2.61 Dauphin County, Derry Township School District 64 3.3.2.62 Dauphin County, Derry Township School District, 65 Hershey Intermediate Elementary School 3.3.2.63 Dauphin County, Derry Township School District, 65 Hershey Middle School 3.3.2.64 Dauphin County, Harrisburg School District 65 4

0

Unclassified Radiological Emergency Preparedness Program (REP)

After Action Report/Improvement Plan Three Mile Island Nuclear Generating Station 3.3.2.65 Dauphin County, Harrisburg School District, 66 Harrisburg High School 3.3.2.66 Dauphin County, Harrisburg School District, Scott 66 School 3.3.2.67 Dauphin County, Harrisburg School District, 66 Shimmell School 3.3.2.68 Dauphin County, LowerDauphin School District 67 3.3.2.69 Dauphin County, Lower Dauphin School District, 68 Lower Dauphin High School 3.3.2.70 Dauphin County, Lower Dauphin School District, 68 Price Building 3.3.2.71 Dauphin County, Lower Dauphin School Distirct, 68 South Hanover Elementary School 3.3.2.72 Dauphin County, Middletown Area School District 68 3.3.2.73 Dauphin County, Middletown Area School District, 69 Middletown High School 3.3.2.74 Dauphin County', MiltonHershey School 69 3.3.2.75 Dauphin County, Steelton-Highspire School District 69 3.3.2.76 Dauphin County,'Steelton-Highspire School District, 69 Steelton-Highspire High School 3.3.2.77 Lancaster County, Donegal School District 70 3.3.2.78 Lancaster County, Donegal School District, Donegal 70 High School 3.3.2.79 Lancaster County, Donegal School District, Donegal 70 Springs Elementary School 3.3.2.80 Lancaster County, Elizabethtown Area School 71 District 3.3.2.81 Lancaster County, Elizabethtow Area School 71 District, East High Street Elemementary School 3.3.2.82 Lancaster County, Elizabethtown Area School 71 District, Fairview Elementary School 3.3.2.83 Lancaster County, Elezabethtown Aera School 71 District, Mill Road Elementary School 3.3.2.84 Lebanon County, Palmyra Area School District 72 3.3.2.85 Lebanon County, Palmyra Area School District, 72 Palmyra High School 3.3.2.86 York County, Central York School District 72 5

Unclassified Radiological Emergency Preparedness Program (REP)

After Action Report/lmprovcment Plan Three Mile Island Nuclear Generating Station 3.3.2.87 York County, Central York School District, Central 73 York Middle School 3.3.2.88 York County, Central York School District, Hayshire 73 Elementary School 3.3.2.89 York County, Central York School District, 73 Roundtown Elementary School 3.3.2.90 York County, Dover Area School Distriict 73 3.3.2.91 York County, Dover Area School District, Dover 75 Intermediate School 3.3.2.92 York County, Eastern York School District 75 3.3.2.93 York County, Eastern York School District, Kreutz 76 Creek Elementary School 3.3.2.94 York County, Northeastern School District 76 3.3.2.95 York County, Northeastern School District, 76 Northeastern Middle School 3.3.2.96 York County, Northeastern School District, Shallow 76 Brook Intermediate School, 3.3.2.97 York County, Northeastern School District, Spring 77 Forge Intermediate School 3.3.2.98 York County, Northeastern School District, York 77 Haven Elementary School 3.3.2.99 York County, West Shore School District 77 3.3.2.100 York County, West Shore School District, Allen 77 Middle School 3.3.2.101 York County, West Shore School District, Cedar 78 Cliff High School 3.3.2.102 York County, West Shore School District, Highland 78 Elementary School 3.3.2.103 York County, West Shore School District, New 78 Cumberland Middle School 3.3.2.104 York County, West Shore School District, Red Mill 78 Elementary School 3.3.2.105 Lebanon County, Eastern Lebanon High School 79 Complex 3.3.3 Support Jurisdictions 79 3.3.3.1 Cumberland County Mass Care Center, Big Spring 79 High School 3.3.3.2 Lancaster County Mass Care Center, Manheim 79 Township High School 6

41

Unclassified Radiological Emergency Preparedness Program (REP)

After Action Report/Improvement Plan Three Mile Island Nuclear Generating Station 3.3.3.3 Adams County Emergency Operations Center 79 3.3.3.4 Franklin County Emergency Operations Center 80 3.3.3.5 Franklin County Reception Center, Faust Junior 80 High School 3.3.3.6 Franklin County Monitoring.and Decontamination 80 Center, Faust Junior High School 3.3.3.7 Schuylkill County Emergency Operations Center 81 3.3.3.8 Schuylkill County Reception Center, Blue Mountain 81 High School 3.3.3.9 Schuylkill County Monitoring and Decontamination 81 Center, Blue Mountain High School 3.3.3.10 Schuylkill County Mass Care Center, Blue Mountain 82 High School 3.3.4 Private Organizations 82 3.3.4.1 Exelon Joint Information Center 83 Section 4: Conclusion 84 Appendix A: Exercise Timeline 85 Appendix B: Exercise Evaluators and Team Leaders 89 Appendix C: Acronyms and Abbreviations 94 Appendix D: Exercise Plan 98 Appendix E: Extent of Play 123 7

0 Unclassified Radiological Emergency Preparedness Program (REP)

Three Mile Island Nuclear Generating Station After Action Report/Improvement Plan This page is intentionally blank.

0 8

0

Unclassified Radiological Emergency Preparedness Program (REP)

After Action Report/Improvement Plan Three Mile Island Nuclear Generating Station EXECUTIVE

SUMMARY

==

Introduction:==

On December 7, 1979, the President directed the Federal Emergency Management Agency (FEMA) to assume the lead responsibility for all off-site nuclear planning and response. FEMA's activities were conducted pursuant to 44 Code of Federal Regulations (CFR) Parts 350, 351 and 352. These regulations are a key element in the Radiological Emergency Preparedness (REP)

Program that was established following the Three Mile Island Nuclear Station accident in March 1979.

44 CFR 350 establishes the policies and procedures for FEMA's initial and continued approval of State and local governments' radiological emergency planning and preparedness for commercial nuclear power plants. This approval is contingent, in part, on State and local government participation in joint exercises with licensees.

FEMA's responsibilities in radiological emergency planning for fixed nuclear facilities include the following:

Taking the lead in offsite emergency planning and in the review and evaluation of Radiological Emergency Response Plans (RERPs) and procedures developed by State and local governments; Determining whether such plans and procedures can be implemented on the basis of observation and evaluation of exercises of the plans and procedures conducted by State and local governments; Responding to requests by the U.S. Nuclear Regulatory Commission (NRC) pursuant to the Memorandum of Understanding between the NRC and FEMA dated June 17, 1993 (Federal Register, Vol. 58, No. 176, September 14, 1993; and Coordinating the activities of the following Federal agencies with responsibilities in the radiological emergency planning process:

- U.S. Department of Commerce,

- U.S. Nuclear Regulatory Commission, 9

Unclassified Radiological Emergency Preparedness Program (REP)

After Action Report/Improvement Plan Three Mile Island Nuclear Generating Station

- U.S. Environmental Protection Agency,

- U.S. Department of Energy,

- U.S. Department of Health and Human Services,

- U.S. Department of Transportation,

- U.S. Department of Agriculture,

- U.S. Department of the Interior, and

- U.S. Food and Drug Administration.

Representatives of these agencies serve on the FEMA Region III Radiological Assistance Committee (RAG), which is chaired by FEMA.

A REP exercise was conducted on April 12th and 13th, 2011 to assess the capabilities of State and local emergency preparedness organizations in implementing their RERPs and procedures to protect the public health and safety during a radiological emergency involving Three Mile Island Nuclear Generating Station (TMI). The purpose of this exercise report is to present the exercise results and findings on the performance of the off-site response organizations (OROs) during a simulated radiological emergency.

The findings presented in this report are based on the evaluations of the Federal evaluator team, with final determinations made by the FEMA Region III RAC Chairperson and approved by FEMA Headquarters.

These reports are provided to the NRC and participating States. State and local governments utilize the findings contained in these reports for the purposes of planning, training, and improving emergency response capabilities.

The criteria utilized in the FEMA evaluation process are contained in the following:

NUREG-0654/FEMA-REP-1, Rev. 1, "Criteria for Preparation and Evaluation of Radiological Emergency Response Plans and Preparedness in Support of Nuclear Power Plants," November 1980; FEMA Guidance Memoranda MS-1, "Medical Services," November 1986; FEMA-REP-14, "Radiological Emergency Preparedness Exercise Manual," September 1991; 10 a

Unclassified Radiological Emergency Preparedness Program (REP)

After Action Report/Improvement Plan Three Mile Island Nuclear Generating Station 66 FR 47546, "FEMA Radiological Emergency Preparedness: Alert and Notification,"

September 12, 2001; and 67 FR 20580, "FEMA Radiological Emergency Preparedness: Exercise Evaluation Methodology," April 25, 2002.

Section 1 of this report, entitled "Exercise Overview," presents the Exercise Planning Team and the Participating Organizations.

Section 2, titled "Exercise Design Summary," includes the "Purpose and Design," "Exercise Objectives, Capabilities, and Activities," and, the, "Scenario Summary."

Section 3 of this report, entitled "Analysis of Capabilities," presents detailed information on the demonstration of applicable exercise! evaluation areas at each jurisdiction or functional entity evaluated in a jurisdiction-based, issues-only format. This section also contains: (1) descriptions of all Deficiencies and Areas Requiring Corrective Action (ARCAs) assessed during this exercise, recommended corrective actions, and the State and local governments' schedule of corrective actions for each identified exercise issue and (2) descriptions of ARCAs assessed during previous exercises and resolved at this exercise, including the corrective action demonstrated, as well as ARCAs assessed during previous exercises and scheduled for demonstration at this exercise which remain unresolved.

Section 4, "Conclusion," is a description of the.Region's overall assessment of the capabilities of the participating organizations.

Appendix A - Improvement Plan. A description of Areas Requiring Corrective Action, the parties responsible for implementing a corrective action plan and time frame for completion.

Appendix B - Exercise Time Line. A table that depicts the times that events and notifications were noted at participating agencies and locations.

Appendix C - Exercise Evaluators and Team Leaders. A table listing the names, organizations, and evaluation responsibilities of the evaluators and management.

11

Unclassified Radiological Emergency Preparedness Program (REP)

After Action Report/Improvement Plan Three Mile Island Nuclear Generating Station Appendix D - Acronyms and Abbreviations. An alphabetized table defining the acronyms and abbreviations used in this report.

Appendix E - Exercise Plan. A narrative description of information developed to implement the exercise including the Extent of Play Agreemant with a detailed description of the exercise criteria and the participants' expected responses to the exercise scenario.

EPZ

Description:

The TMI Generating Station (40* 9' 12" N/76* 43' 25" W) is a nuclear power plant operated by Exelon Nuclear. The site consists of two pressurized water-type units. Unit One is an 819-megawatt (MW) reactor, and Unit Two is a 906-MW reactor. Unit 1 received its license in June 1974 and began commercial operation in September 1974. Unit 2 began commercial operation in February 1978; it was damaged in March 1979 and has been shut down and placed in a monitored storage mode.

The minimum exclusion distance specified for the TMI plant is 2,000 feet. Included within the 2,000-foot radius are a portion of Three Mile Island, a portion of Shelly Island, and a portion of the Susquehanna River. Exelon Nuclear and GPU Nuclear Corporation own all the land within the exclusion area.

The TMI plant is located in south-central Pennsylvania in Londonderry Township, Dauphin County. The site is part of an 814-acre tract consisting of several adjacent islands in the Susquehanna River. The power plant is located on Three Mile Island, which is one of the largest islands of the group. The site is at an elevation of 300 feet above mean sea level, relatively flat, and wooded on the periphery and the southern portion. Of the 470 acres that make up the island, the plant occupies approximately 200 acres in the northern portion.

Soils on the island are of the Duncannon-Chavies-Tioga Association, which is comprised of deposits of alluvial sand, silt, and clay. Underlying bedrock is red sandstone and shale.

The normal pool elevation of the Susquehanna River in this area is 277 feet above msl. Hills on both sides of the river in this vicinity rise to elevations of over 500 feet. The plant grade is 300 feet above msl.

12 0

Unclassified Radiological Emergency Preparedness Program (REP)

After Action Report/Improvement Plan Three Mile Island Nuclear Generating Station An access bridge for plant personnel connects State Route 441 with the north end of the island. A wooden bridge connects the southern portion of the island with State Route 441. Conrail lines are located on both sides of the river; the closest is a one-track line adjacent and parallel to Route 441 on the east shore.

The area within 10 miles of the TMI Nuclear Power Station is located in south-central Pennsylvania, and includes portions of Cumberland, Dauphin, Lancaster, Lebanon, and York counties. The site is surrounded mostly by farmland within a 10-mile radius. The nearest community is Goldsboro Borough, on the west shore of the Susquehanna River, 1 mile from the plant. The nearest major population center with more than 25,000 people is Harrisburg (population 53,624), which lies just over 10,miles to the north.

Twenty-three industrial firms are located withina 5-mile radius; they employ approximately 2,400 people. The Harrisburg International Airport is located 2 miles northwest of the TMI plant.

An NRC estimate of aircraft risk to TMI Units One and Two indicates an acceptably low risk for either unit, provided fewer than 2,400 operations per year are by aircraft in excess of 200,000 pounds. The NRC requires Exelon to continue periodic monitoring and reporting of airport usage and will reevaluate the adequacy of plant protection if aircraft traffic is reliably projected to exceed 2,400 operations per. year. The major railroads operating in the EPZ include Amtrak, Blue Mountain and Ridge, Chessie System, Conrail, and the Maryland and Pennsylvania Railroad.

The climate of'the five-county risk EPZ is mild and humid. Weather is variable because the prevailing westerly winds bring both high-and low-pressure systems through the area every few days. Average annual precipitation for the southern portion of the county is about 38 inches, and the average annual temperature is 52 degrees F.

On the basis of the 2010 census, the total population of the 10-mile EPZ is 226,160. There are 97 sirens used to provide coverage of the plume exposure pathway EPZ. The county in which it is located operates each siren system.

13

Unclassified Radiological Emergency Preparedness Program (REP)

After Action Report/improvement Plan Three Mile Island Nuclear Generating Station SECTION 1: EXERCISE OVERVIEW 1.1 Exercise Details Exercise Name Three Mile Island Nuclear Generating Station Type of Exercise Plume Exercise Date April 12, 2011 Program Department of Homeland Security/FEMA Radiological Emergency Preparedness Program Scenario Type Radiological Emergency 1.2 Exercise Planning Team Leadership Matthew Wiedemer Site Specialist FEMA Region III Technological Hazards Prorgam Specialist 615 Chestnut Street 1 Independence Mall, 6th Fl Philadelphia, Pennsylvania, 19106 215-931-5659 Matthew.Wiedemer@dhs.gov Laurin Fleming Exercise Planning Team Lead Pennsylvania Emergency Management Agency Emergency Management Specialist 14 4

Unclassified Radiological Emergency Preparedness Program (REP)

After Action Report/Improvement Plan Three Mile Island Nuclear Generating Station 2605 Interstate Drive Harrisburg, Pennsylvania, 17110 717-651-2119 laufleming@state.pa.us Darrell Hammons Planning Teams Member FEMA Region III Radiological Emergency Preparedness Branch Chief 1 Independence Mall, 6th Fl 615 Chestnut St.

Philadelphia, Pennsylvania, 19106 215-931-5546 Darrell.Hammons@dhs.gov John Price Planning Team Member FEMA Region III Senior Technological Hazards Program Specialist 1 Independence Mall, 6th fl 615 Chestnut St.

Philadelphia, Pennsylvania, 19106 215-931-5570 john.price@dhs.gov Henry Tamamini Exercise Planning Team Member Pennslyvania Emergency Management Agency Technological Hazards Planning Division Chief 2605 Interstate Dr Harrisburg, Pennsylvania, 17110 717-651-2723 htamanini@state.pa.us 15

Unclassified Radiological Emergency Preparedness Prograin (REP)

After Action Report/Improvement Plan Three Mile Island Nuclear Generating Station 1.3 Participating Organizations Agencies and organizations of the following jurisdictions participated in the Three Mile Island Nuclear Generating Station exercise:

State Jurisdictions PA Department of Environmental Protection Bureau of Radiation Protection Pennsylvania Bureau of Radiation Protection Pennsylvania Department of Corrections Pennsylvania Department of Environmental Protection Pennsylvania Department of General Services Pennsylvania Department of Health Pennsylvania Department of Public Works Pennsylvania Department of Transportation Pennsylvania Emergency Management Agency Pennsylvania National Guard Pennsylvania Office of Administration Pennsylvania Public Utilities Commission Pennsylvania State Police Risk Jurisdictions Allen Middle School Principal Allen Middle School Staff Annville Union Hose Fire Company Avon Volunteer Fire Department Capital Area Intermediate Unit # 15 Staff Captial Area School For The Arts Staff Cedar Cliff High School Principal and Staff Central Dauphin East High School Staff Central Dauphin East High School Superintendent Central York Middle School Assistant Principal Central York Middle School Principal Central York School District Staff Central York School District Superintendent Cumberland County Cumberland County Public Safety 16 a

Unclassified Radiological Emergency Preparedness Program (REP)

After Action Report/Improvement Plan Three Mile Island Nuclear Generating Station Cumberland County Special Hazards Operations Team Cumberland Decontamination Strike Team Dauphin County Emergency Management Agency Dauphin County HAZMAT Department of Public Safety Derry Township Police Derry Township Superintendent Donegal (Maytown) Fire Donegal Ambulance Donegal Communications Donegal High School Principal Donegal PIO Donegal Police Donegal Public Works Donegal School District Project Control Manager Donegal Springs Elementary School Principal Donegal Springs Elementary School Staff Donegal Supervisors Dover Area School District Administration and Staff Dover Intermediate School Principal Dover Intermediate School Staff Eastern York Administration and Staff Elizabethtown Emergency Management Agency Elizabethtown Fire Department Elizabethtown Police Department Elizabethtown Public Works Department Environmental Products and Services of Vermont Inc (contractor to Dauphin County)

Fairview Elementary School Principal Glen Rock Hose & Ladder Co.

Hampden Township Fire Company Hayshire Elementary School Assistant Principal Hayshire Elementary School Principal Highland Elementary School Principal 17

Unclassified Radiological Emergency Preparedness Program (REP)

After Action Report/Improvement Plan Three Mile Island Nuclear Generating Station Highland Elementary School Staff Kreutz Creek Elementary School Principal Lancaster County Dept of Education Lancaster County Emergency Management Agency Lancaster County Police Department Lancaster County Public Safety Lancaster County RACES Lancaster County Sheriff Lancaster Medial Services Lebanon County Hazardous Materials Team Lebanon County Hazmat Team Lebanon Valley Chapter Lower Dauphin High School Principal Lower Dauphin High School Staff Middletown Area School District Principal Mill Road Elementary School Principal Milton Hershey School EOC Staff Monaghan Township Volunteer Fire Company Mount Joy Fire Department Mount Joy Police New Cumberland Borough Fire Department New Cumberland Borough Police Department New Cumberland Middle School Principal and Staff New Cumberland MS Crisis Team New Cumberland MS Principal Newville Community EMS Newville Fire Company Northeastern School District Assistant Superintendent Northeastern Middle School Principal and Staff North West Regional Emergency Medical Services Palmyra High School Principal Price School Principal RACES Red Mill Elementary School Principal 18 0

Unclassified Radiological Emergency Preparedness Program (REP)

After Action Report/Improvement Plan Three Mile Island Nuclear Generating Station Red Mill Elementary School Staff Rheems Fire Department Roundtown Elementary Principal and Staff Scott Early Childhood Center Staff Shallow Brook Intermediate Principal and Staff Shimmell School Principal Shimmell School Staff South Hanover Elementary, School Principal Spring Forge Bus Driver Spring Forge Nurse Spring Forge Principal Steelton-Highspire School Principal Steelton-Highspire School Staff Swatara Middle School Principal Swatara Middle School Staff Tri Community School Principal Tri Community School Staff West shore Bureau of Fire West Shore Emergency Medical Services (MS)

West Shore School District Administration and Staff York County ARES/RACES York County HAZMAT York Haven Elementary School Principal York County Office of Emergency Management York County Commissioners York County 911 York County Penn State Cooperative Extension York Haven Elementary School Staff Support Jurisdictions Adams County American Red Cross County Department of Corrections County RACES Team Department of Transportation 19

Unclassified Radiological Emergency Preparedness Program (REP)

After Action Rcport/Improvement Plan Three Mile Island Nuclear Generating Station Fire Department Health Department Orwigsburg Fire Department Pennsylvania Department of Corrections Schuylkill County - Police Department Pottsville Fire Department Schulykill County Emergency management Agency Schuylkill County 911 Center Schuylkill County Emergency Management Agency Schuylkill County Geographic Information System Office Schuylkill County Incident Management Team Schuylkill County Local Emergency Planning Committee Schuylkill County Planning Department Schuylkill County Sheriff Department United States Department of Agriculture Private Organizations Exelon 20 4

Unclassified Radiological Emergency Preparedness Program (REP)

After Action Report/Improvement Plan Three Mile Island Nuclear Generating Station SECTION 2: EXERCISE DESIGN

SUMMARY

2.1 Exercise Purpose and Design On April 12, 2011, a full-scale plume exercise was conducted in the 10-mile plume exposure pathway, emergency planning zone (EPZ) around the Three Mile Island Generating Station (TMI) by the Federal Emergency Management Agency (FEMA), Region III. Out-of-sequence demonstrations were conducted on April 13, 2011. The purpose of the exercise and the out-of-sequence demonstrations was to assess the level of State and local preparedness in responding to a radiological emergency. The exercise and out-of-sequence demonstrations were held in accordance with FEMA's policies and guidance concerning.the exercise of State and local radiological emergency response plans (RERP) and procedures.

The most recent prior full-scale exercise at this site was conducted on April 14, 2009.

FEMA wishes to acknowledge the efforts of the many individuals in the Commonwealth of Pennsylvania, the risk counties of Cumberland, Dauphin, Lancaster, Lebanon, and York; the risk jurisdictions of New Cumberland Borough, Harrisburg. City, Highspire Borough, Londonderry Township, Lower Paxton Township, Paxtang Borough, South Hanover Township, East Donegal Township, Elizabethtown Borough/West Donegal Township/Mount Joy Township, South Londonderry Township, Dover Township, Lewisberry Borough/Newberry Township, Manchester Township, and Mt. Wolf/ East Manchester/ Manchester Borough; and the support counties of Adams, Franklin, and Schuylkill who were evaluated at this exercise.

Protecting the public health and safety is the full-time job of some of the exercise participants and an additional assigned responsibility for others. Still others have willingly sought this responsibility by volunteering to provide vital emergency services to their communities.

Cooperation and teamwork of all the participants were evident during this exercise.

This report contains the final evaluation of the biennial exercise and the evaluation of the following out-of-sequence activities:

- Reception Center/Monitoring and Decontamination and Mass Care: Conducted on April 13, 2011 in Adams, Cumberland, Dauphin, Franklin, Lancaster, Lebanon, Schuylkill, and York Counties.

21

Unclassified Radiological Emergency Preparedness Program (REP)

After Action Report/Improvement Plan Three Mile Island Nuclear Generating Station

  • Emergency Worker Monitoring and Decontamination: Conducted on April 13, 2011 in Cumberland, Lancaster, Lebanon, and York Counties.
  • Traffic/Access Control: Conducted on April 13, 2011 at the Harrisburg State Police Barracks.

" Schools: Conducted on April 12, 2011 in Dauphin, Lancaster, Lebanon, and York Counties.

2.2 Exercise Objectives, Capabilities and Activities The objective of the TMI 2011 Plume Exercise is to demonstrate the capabilities of State and local emergency management agencies to mobilize emergency management and emergency response personnel, to activate emergency operations centers and support facilities, and to protect the health, lives, and property of the, citizens residing within the 10-mile Emergency Planning Zone (EPZ).

To demonstrate the ability to communicate between multiple levels of government and provide timely, accurate, and sufficiently detailed information to: the public, the emergency management agencies use a variety of resources including radios, telephones, the Internet, the media, the Emergency Alert System (EAS), and the utility Alert and Notification System sirens (ANS). All of these communications resources were employed and evaluated. The EAS and ANS were simulated and media information was prepared but not actually released..

An essential capability of the Radiological Emergency Preparedness Program (REPP) is to evacuate, monitor and decontaminate if necessary, and provide temporary care and shelter to displaced residents from the EPZ. The ability of the support counties to mobilize personnel and resources to establish reception, monitoring and decontamination, and mass care centers was demonstrated.

The protection of school children is also a vital mission of the REPP. School districts and selected schools demonstrated the capability to communicate and coordinate the collection, evacuation, transportation and shelter of students attending schools within the EPZ. Provisions for students who live within the EPZ but attend school outside were also evaluated.

22 a

Unclassified Radiological Emergency Preparedness Program (REP)

After Action Report/Improvement Plan Three Mile Island Nuclear Generating Station 2.3 Scenario Summary NOTE: All information below is scenario simulated. The times for the events are approximate.

At 1600 on April 12, 2011, the exercise begins. TMI Unit 1 a Pressurized Water Reactor is operating at 100 percent power. The weather forecast is winds at 7 miles per hour (mph) from the West to the East. The temperature high today will be 60 degrees.

At 1605 a mobile crane crashes into the Condensate Storage Tank and there is visible damage to the tank. At 1620, an ALERT is declared by the Shift Manager in accordance with Emergency Action Level (EAL) HA5, "vehicle crash within the Protected Area resulting in visible damage to equipment contained in any Table H2 area": There is no radioactive release as a result of this event. TMI Unit 1 continues to operate at 100 percent power.

At 1645 a control rod will drop into the core and the reactor power drops to 55 percent. At 1715, the main turbine trips and this causes an automatic shutdown of the reactor. At 1730, there is a tube rupture in the "A" steam generator with a leak rate of reactor coolant into the steam generator of 700 gallons per minute. This causes the reactor pressure to lower to 1600 pounds per square inch and results in the initiation of the engineered safeguards actuation system (ESAS). At 1730, an abnormal release of radioactive material commences through the stuck open atmospheric dump valve on steam generator "A". The sourcefor this release is normal reactor coolant radioactivity that is significantly elevated by the rapid depressurization of the reactor coolant system when the steam generator tube rupture occurs. The fuel clad remains intact. This release continues through the end of the exercise. The wind speed is 4 mph, the wind direction is from the west to the east and the atmospheric stability class is B. A Site Area Emergency should be declared by 1745 based on Emergency Action Level FS 1, "Steam generator tube rupture that requires ESAS actuation and primary to secondary leak rate greater than 10 gallons per minute".

At 1800 a low pressure injection pump trips greatly reducing the ability to add water into the reactor system. At 1900, a large reactor coolant leak commences into the containment. By approximately 1915, a General Emergency should be declared based on Emergency Action Level FG 1, "greater than 25 degree superheat and steam generator tube rupture with ESAS actuation and primary to secondary leak rate of greater than 10 gallons per minute". The Licensee issues a Protective Action Recommendation as, "Evacuate 0-5 miles 3600 and shelter the remainder of the 10 mile EPZ and advise the general public to administer KI in accordance with the state plan." The Licensee and State dose projections indicate that the EPA protective 23

Unclassified Radiological Emergency Preparedness Program (REP)

After Action Report/Improvement Plan Three Mile Island Nuclear Generating Station action guides (PAG) are not exceeded offsite. The wind speed is 4 mph and the wind direction is from the west to the east. The wind direction continues to shift slowly and by 2100 the wind direction is from the west south west into the east north east.

At 2100 the TMI Evaluated Exercise will end if all objectives are met.

24 4

Unclassified Radiological Emergency Preparedness Program (REP)

After Action Rcport/Improvement Plan Three Mile Island Nuclear Generating Station SECTION 3: ANALYSIS OF CAPABILITIES 3.1 Exercise Evaluation and Results Contained in this section are the results and findings of the evaluations of all jurisdictions and locations that participated in the April 12 and 13, 2011, biennial Radiological Emergency Preparedness (REP) Exercise.

Each jurisdiction and functional entity were evaluated on the basis of its demonstration of the Exercise Evaluation Area Criteria contained in the REP Exercise Evaluation Methodology.

Detailed information on the Exercise Evaluation Area Criteria and the Extent-of-Play Agreement used in this exercise are found in Appendix E.

The Pennsylvania Bureau of Radiation Protection Field Monitoing Teams, Adams County Monitoring and Decontamination and Mass Care, and Lacaster County Emergency Operations Center participated in this exercise, but were exempted from evaluation because they had been previously evaluated in another exercise. Therefore, results of their participation will appear as an "N" on Table 3.1, "Summary of Exercise Evaluation."

3.2 Summary Results of Exercise Evaluation The State and local organizations, except where noted in this report, demonstrated knowledge of their emergency response plans and procedures and adequately implemented them. There were no Deficiencies and nine Areas Requiring Corrective Action (ARCAs) identified as a result of this exercise; four of the ARCAs were successfully re-demonstrated during the exercise. Five ARCAS were re-demonstrated on April 29, and May 9, 2011. One ARCA from a previous exercise was successfully re-demonstrated on May 2, 2011. Two new planning issues were identified, both of which have been resolved. (see Appendix 5 for resolution for all planning issues) 25

a Unclassified Radiological Emergency Preparedness Program (REP)

Three Mile Island Nuclear Generating Station After Action Report/Improvement Plan Table 3.1 - Summary of Exercise Evaluation (12 pages) t-'J DATE: 2011-04-12 SITE: Three Mile Island Nuclear Generating Station, PA U

M: Met, A: ARCA, D: Deficiency, P: Plan Issue, N: Not C)

Q Demonstrated 0 U w

0o Emergency Operations Management Mobilization lal M

M M M

Facilities IbI Direction and Control 1dcl M

M M

Communications Equipment Idl M M M M M Equip & Supplies to support operations lel M

M M M M M M M Protective Action Decision Making Emergency Worker Exposure Control 2al M

M Radiological Assessment and PARs 2bl M

Decisions for the Plume Phase -PADs 2b2 M

PADs for protection of special populations 2c 1 M

Rad Assessment and Decision making for the Ingestion Exposure Pathway 2d1 Rad Assessment and Decision making concerning Relocation, Reentry, and 2el Return Protective Action Implementation Implementation of emergency worker exposure control 3al M M M M

Implementation of KI decision 3bl M

M M Implementation of protective actions for special populations - EOCs 36 M

Implementation of protective actions for Schools 3c2 M

Implementation of traffic and access control 3d1 M

M M Impediments to evacuation are identified and resolved 3d2 M

M M Implementation of ingestion pathway decisions - availability/use of info 3el Materials for Ingestion Pathway PADs are available 3e2 Implementation of relocation, re-entry, and return decisions.

31f1 Field Measurement and Analysis Adequate Equipment for Plume Phase Field Measurements 4al Field Teams obtain sufficient information 4a2 Field Teams Manage Sample Collection Appropriately 4a3 Post plume phase field measurements and sampling 4b1 Laboratory operations 4cl Emergency Notification and Public Info Activation of the prompt alert and notification system 5al M M M

Activation of the prompt alert and notification system - Fast Breaker 5a2 Activation of prompt alert and notification system-Excptn Areas/Bkup RA 5a3 Emergency information and instructions for the public and the media 5bl MIM M

Support Operations/Facilities Mon/decon of evacuees and emergency workers, and registration of evacuees 6al M M M M Mon/decon of emergency worker equipment 6b 1 M

Temporary care of evacuees 6cI M

Transportation and treatment of contaminated injured individuals 6dl 61 0

26

Unclassified Radiological Emergency Preparedness Program (REP)

Three Mile Island Nuclear Generating Station After Action Report/Improvement Plan Table 3.1 - Summary of Exercise Evaluation (Continued. page 2/12) 0 U

0 DATE: 2011-04-12 SITE: Three Mile Island Nuclear Generating Station, PA w

M: Met, A: ARCA, D: Deficiency, P: Plan Issue, N: Not U U 0 U

D em onstrated A

z z

o o

o o

o o

Ulu a

~

CS CSC z

z Emergency Operations Management Mobilization lal M

M M M M

Facilities Ibi Direction and Control 1cl M

M M M M

Communications Equipment ldl M MM M

M-M M M Equip & Supplies to support operations lel M M M M M M M M M M Protective Action Decision'Making Emergency Worker Exposure Control 2al M

Radiological Assessment and PARs 2bl1 Decisions for the Plume Phase -PADs 2b2 PADs for protection of special populations.

2cl.

M M

M M M

Rad Assessment and Decision making for the Ingestion Exposure Pathway 2dl Rad Assessment and Decision making concerning Relocation, Reentry, and 2el Return Protective Action Implementation Implementation of emergency worker exposure control 3al M M M M M M M M Implementation ofKI decision 3bl M MIM MIM M M Implementation of protective actions for special populations - EOCs 30 M

M M M

-M Implementation of protective actions for Schools 3c2 M

M Implementation of traffic and access control 3d1 M

M M M M

Impediments to evacuation are identified and resolved 3d2 M

M M M M

Implementation of ingestion pathway decisions - availability/use of info 3e 1 Materials for Ingestion Pathway PADs are available 3e2 Implementation of relocation, re-entry, and return decisions.

3fl Field Measurement and Analysis Adequate Equipment for Plume Phase Field Measurements 4al Field Teams obtain sufficient information 4a2 Field Teams Manage Sample Collection Appropriately 4a3 Post plume phase field measurements and sampling 4b1 Laboratory operations 4cl Emergency Notification and Public Info Activation of the prompt alert and notification system 5al M

M M

M Activation of the prompt alert and notification system - Fast Breaker 5a2 Activation of prompt alert and notification system-Excptn Areas/Bkup RA 5a3 M M M M Emergency information and instructions for the public and the media 5bl M

Support Operations/Facilities Mon/decon of evacuees and emergency workers, and registration of evacuees 6al M M M Mon/decon of emergency worker equipment 6b1 M

Temporary care of evacuees 6cl M M Transportation and treatment of contaminated injured individuals 6dl 27

a Unclassified Radiological Emergency Preparedness Program (REP)

Three Mile Island Nuclear Generating Station After Action Report/Improvement Plan Table 3.1 - Summary of Exercise Evaluation (Continued. page 3/12)

U

.L DATE: 2011-04-12 0

SITE: Three Mile Island Nuclear Generating Station, PA U

U ~

C U

CLU U M: Met, A: ARCA, D: Deficiency, P: Plan Issue, N: Not O

0° 0 U U U r U Demonstrated QO 0 0 QOO Emergency Operations Management Mobilization lal M M M N Facilities IbI M

M M1 M

Direction and Control ll M M M MI Communications Equipment ldl MIMIM N M

Equip & Supplies to support operations lel M M M N M M M Protective Action Decision Making Emergency Worker Exposure Control 2al N

Radiological Assessment and PARs 2bl Decisions for the Plume Phase -PADs 2b2 PADs for protection of special populations 2cl M M M N Rad Assessment and Decision making for the Ingestion Exposure Pathway 2d]

Rad Assessment and Decision making concerning Relocation;Reentry, and 2el Return Protective Action Implementation Implementation of emergency worker exposure control 3al M M M M M M

Implementation of KI decision 3b]

M M M N Implementation of protective actions for special populations - EOCs 3cl M M M N Implementation of protective actions for Schools 3c2 N

Implementation of traffic and access control 3dl M M M N M

Impediments to evacuation are identified and resolved 3d2 M M M N Implementation of ingestion pathway decisions - availability/use of info 3el Materials for Ingestion Pathway PADs are available 3e2 Implementation of relocation, re-entry, and return decisions.

3fl Field Measurement and Analysis Adequate Equipment for Plume Phase Field Measurements 4al Field Teams obtain sufficient information 4a2 Field Teams Manage Sample Collection Appropriately 4a3 Post plume phase field measurements and sampling 4b 1 Laboratory operations 4c 1 Emergency Notification and Public Info Activation of the prompt alert and notification system 5al M M M N Activation of the prompt alert and notification system - Fast Breaker 5a2 Activation of prompt alert and notification system-Excptn Areas/Bkup RA 5a3 N

Emergency information and instructions for the public and the media 5b 1 N

Support Operations/Facilities Mon/decon of evacuees and emergency workers, and registration of evacuees 6al M M M M M Mon/decon of emergency worker equipment 6b1 M

Temporary care of evacuees 6cl1 M

1 M M M

Transportation and treatment of contaminated injured individuals 6dl a

a 28 6

Unclassified Radiological Emergency Preparedness Program (REP)

Three Mile Island Nuclear Generating Station After Action Report/Improvement Plan Table 3.1 - Summary of Exercise Evaluation (Continued. page 4/12)

DATE: 2011-04-12 SITE: Three Mile Island Nuclear Generating Station, PA M: Met, A: ARCA, D: Deficiency, P: Plan Issue, N: Not Demonstrated U-U-

H 0U'a Ud H

U-C-)

U-0c-)

'a 0

Ua 0U~

0 0U-U-

0 76 0

U U

7-0 L~lkviavI xxp~t~~ital)thLI Mobilization lal M M M Facilities IbI M M M M M Direction and Control ic1 M

M Communications Equipment Idl M M M Equip & Supplies to support operations lel M M M Protective Action Decision Making Emergency Worker Exposure Control 2al Radiological Assessment and PARs 2bl Decisions for the Plume Phase -PADs 2b2 PADs for protection of special populations 2cl M

M Rad Assessment and Decision making for the Ingestion Exposure Pathway 2d1 Rad Assessment and Decision making concerning Relocation, Reentry, and 2e1 Return Protective Action Implementation Implementation of emergency worker exposure control 3al M M M M M Implementation of KI decision 3bl M M M Implementation of protective actions for special populations - EOCs 3cl M

M Implementation of protective actions for Schools 3c2 Implementation of traffic and access control 3d1 M

M Impediments to evacuation are identified and resolved 3d2 M

M Implementation of ingestion pathway decisions - availability/use of info 3el Materials for Ingestion Pathway PADs are available 3e2 Implementation of relocation, re-entry, and return decisions.

31f1 Field Measurement and Analysis Adequate Equipment for Plume Phase Field Measurements 4al Field Teams obtain sufficient information 4a2 Field Teams Manage Sample Collection Appropriately 4a3 Post plume phase field measurements and sampling 4b 1 Laboratory operations 4c 1 Emergency Notification and Public lnfo Activation of the prompt alert and notification system 5al M M M Activation of the prompt alert and notification system - Fast Breaker 5a2 Activation of prompt alert and notification system-Excptn Areas/Bkup RA 5a3 M M M Emergency information and instructions for the public and the media 5bl Support Operations/Facilities 29

Unclassified Radiological Emergency Preparedness Program (REP)

After Action Report/Improvement Plan Three Mile Island Nuclear Generating Station Mon/decon of evacuees and emergency workers, and registration of evacuees 6al M M M M M Mon/decon of emergency worker equipment 6b1 Temporary care of evacuees 6cl M N M M M Transportation and treatment of contaminated injured individuals 6dl 30 a

Unclassified Radiological Emergency Preparedness Program (REP)

Three Mile Island Nuclear Generating Station After Action Report/Improvement Plan Table 3.1 - Summary of Exercise Evaluation (Continued. page 5/12)

DATE: 2011-04-12 U

SITE: Three Mile Island Nuclear Generating Station, PA En U U w

M: Met, A: ARCA, D: Deficiency, P: Plan Issue, N: Not a

Demonstrated o o o

o o o o o o o M

It4

0)
0) 0 0.)

01 0) 01 0 Emergency Operations Management Mobilization lal M

M Facilities IbN Direction and Control Ic M

M Communications Equipment Idl M MIM M

M M M Equip & Supplies to support operations lel M M M M M M M M M M Protective Action Decision Making Emergency Worker Exposure Control 2al M

Radiological Assessment and PARs 2bl Decisions for the Plume Phase -PADs 2b2 PADs for protection of special populations 2cl M

N Rad Assessment and Decision making for the Ingestion Exposure Pathway 2dl Rad Assessment and Decision making concerning Relocation, Reentry, and 2el Return Protective Action Implementation Implementation of emergency worker exposure control 3al M M M M M

M M M Implementation of KI decision 3bl M M M X M M Implementation of protective actions for special populations - EOCs 3cd I

M M

Implementation of protective actions for Schools 3c2 M

Implementation of traffic and access control 3dl M M M M

M M

Impediments to evacuation are identified and resolved 3d2 M M M M

M Implementation of ingestion pathway decisions - availability/use of info 3e 1 Materials for Ingestion Pathway PADs are available 3e2 Implementation of relocation, re-entry, and return decisions.

3fl Field Measurement and Analysis Adequate Equipment for Plume Phase Field Measurements 4al Field Teams obtain sufficient information 4a2 Field Teams Manage Sample Collection Appropriately 4a3 Post plume phase field measurements and sampling 4b 1 Laboratory operations 4c 1 Emergency Notification and Public Info Activation of the prompt alert and notification system 5al M

M Activation of the prompt alert and notification system - Fast Breaker 5a2 Activation of prompt alert and notification system-Excptn Areas/Bkup RA 5a3 M

M M Emergency information and instructions for the public and the media 5bl M

Support Operations/Facilities Mon/decon of evacuees and emergency workers, and registration of evacuees 6al M

M M Mon/decon of emergency worker equipment 6b1 M

Temporary care of evacuees 6c1 M

Transportation and treatment of contaminated injured individuals 6dl 31

a Unclassified Radiological Emergency Preparedness Program (REP)

Three Mile Island Nuclear Generating Station After Action Report/Improvement Plan Table 3.1 - Summary of Exercise Evaluation (Continued. page 6/12)

U DATE: 2011-04-12 r

)

SITE: Three Mile Island Nuclear Generating Station, PA 0 U U

U C#)IO ý M: Met, A: ARCA, D: Deficiency, P: Plan Issue, N: Not w

U z

Demonstrated w w 4

)'

z Emergency Operations Management Mobilization lal M

M M M M Facilities Ib1 Direction and Control Icl M

M M MM Communications Equipment ldl M

M M M M M M Equip & Supplies to support operations lel M M M M M M M M M M Protective Action Decision Making Emergency Worker Exposure Control 2al M

Radiological Assessment and PARs 2b 1 Decisions for the Plume Phase -PADs 2b2 PADs for protection of special populations 2cl M

M M M M Rad Assessment and Decision making for the Ingestion Exposure Pathway 2dl Rad Assessment and Decision making concerning Relocation, Reentry, and 2el Return Protective Action Implementation Implementation of emergency worker exposure control 3al M M M

M M M M M Implementation ofKI decision 3bl M

M M M M M M Implementation of protective actions for special populations - EOCs 3cl M

M M M Implementation of protective actions for Schools 3c2 M

Implementation of traffic and access control 3dl M

M M M M M Impediments to evacuation are identified and resolved 3d2 M

M M M

M Implementation of ingestion pathway decisions - availability/use of info 3e I Materials for Ingestion Pathway PADs are available 3e2 Implementation of relocation, re-entry, and return decisions.

31f1 Field Measurement and Analysis Adequate Equipment for Plume Phase Field Measurements 4al Field Teams obtain sufficient information 4a2 Field Teams Manage Sample Collection Appropriately 4a3 Post plume phase field measurements and sampling 4b 1 Laboratory operations 4c 1 Emergency Notification and Public Info Activation of the prompt alert and notification system 5al M

M M M M Activation of the prompt alert and notification system - Fast Breaker 5a2 Activation of prompt alert and notification system-Excptn Areas/Bkup RA 5a3 M

M M

Emergency information and instructions for the public and the media 5bl M

Support Operations/Facilities Mon/decon of evacuees and emergency workers, and registration of evacuees 6al M

M M Mon/decon of emergency worker equipment 6b 1 M

Temporary care of evacuees 6c1 M

Transportation and treatment of contaminated injured individuals 6d1 0

32

Unclassified Radiological Emergency Preparedness Program (REP)

Three Mile Island Nuclear Generating Station After Action Report/Improvement Plan Table 3.1 - Summary of Exercise Evaluation (Continued. page 7/12) rC1111 DATE: 2011-04-12 Z*

SITE: Three Mile Island Nuclear Generating Station, PA 4

M: Met, A: ARCA, D: Deficiency, P: Plan Issue, N: Not w

U 0 0 0

0 0

0 0

0 0

Demonstrated

< 4 1 4 1 1 4 A c Emergency Operations Management Mobilization lal M M M

Facilities IbI M

Direction and Control IclMM M M M

Communications Equipment Idl M MM M

M Equip & Supplies to support operations lel M M M M M M M M M Protective Action Decision Making Emergency Worker Exposure Control 2al Radiological Assessment and PARs.

2bl Decisions for the Plume Phase -PADs 2b2 PADs for protection of special populations 2cl Rad Assessment and Decision making for the Ingestion Exposure Pathway 2dl Rad Assessment and Decision making concerning Relocation, Reentry, and 2el Return Protective Action Implementation Implementation of emergency. worker exposure control 3al Implementation of KI decision.

3bl Implementation of protective actions for special populations - EOCs 30 Implementation of protective actions for Schools 3c2 M

Implementation of traffic and access control 3d1 M

M Impediments to evacuation are identified and resolved 3d2 Implementation of ingestion pathway decisions - availability/use of info 3e1 Materials for Ingestion Pathway PADs are available 3e2 Implementation of relocation, re-entry, and return decisions.

3f1 Field Measurement and Analysis Adequate Equipment for Plume Phase Field Measurements 4al Field Teams obtain sufficient information 4a2 Field Teams Manage Sample Collection Appropriately 4a3 Post plume phase field measurements and sampling 4b I Laboratory operations 4c I Emergency Notification and Public Info Activation of the prompt alert and notification system 5a1 Activation of the prompt alert and notification system - Fast Breaker 5a2 Activation of prompt alert and notification system-Excptn Areas/Bkup RA 5a3 Emergency information and instructions for the public and the media 5bl M M M

Support Operations/Facilities Mon/decon of evacuees and emergency workers, and registration of evacuees 6al M M M M Mon/decon of emergency worker equipment 6b 1 Temporary care of evacuees 6c1 M

M Transportation and treatment of contaminated injured individuals 6d

+

33

a Unclassified Radiological Emergency Preparedness Program (REP)

Three Mile Island Nuclear Generating Station After Action Report/Improvement Plan Table 3.1 - Summary of Exercise Evaluation (Continued. page 8/12)

DATE:2011-04-12 E U SITE: Three Mile Island Nuclear Generating Station, PA M: Met, A: ARCA, D: Deficiency, P: Plan Issue, N: Not F on Demonstrated U U U U U C C ) x =

0 0

0 0

0 0

0 0

0 0

al 0 0 0

0 M 0 M M 0 Emergency Operations Management Mobilization lal Facilities 1b1 Direction and Control Ic1 Communications Equipment ldl Equip & Supplies to support operations lel Protective Action Decision Making Emergency Worker Exposure Control 2al Radiological Assessment and PARs 2b I Decisions for the Plume Phase -PADs 2b2 PADs for protection of special populations 2c 0 Rad Assessment and Decision making for the Ingestion Exposure Pathway 2dl Rad Assessment and Decision making concerning Relocation, Reentry, and 2e I Return Protective Action Implementation Implementation of emergency worker exposure control 3al Implementation of KI decision 3b I Implementation of protective actions for special populations - EOCs 3cl Implementation ofprotective actions for Schools 3c2 M M M M M M M M M M Implementation of traffic and access control 3dl Impediments to evacuation are identified and resolved 3d2 Implementation of ingestion pathway decisions - availability/use of info 3e 1 Materials for Ingestion Pathway PADs are available 3e2 Implementation of relocation, re-entry, and return decisions.

3fl Field Measurement and Analysis Adequate Equipment for Plume Phase Field Measurements 4al Field Teams obtain sufficient information 4a2 Field Teams Manage Sample Collection Appropriately 4a3 Post plume phase field measurements and sampling 4b1 Laboratory operations 4cl Emergency Notification and Public Info Activation of the prompt alert and notification system 5al Activation of the prompt alert and notification system - Fast Breaker 5a2 Activation of prompt alert and notification system-Excptn Areas/Bkup RA 5a3 Emergency information and instructions for the public and the media 5bl Support Operations/Facilities Mon/decon of evacuees and emergency workers, and registration of evacuees 6al Mon/decon of emergency worker equipment 6b1 Temporary care of evacuees 6c1 Transportation and treatment of contaminated injured individuals 6d]

0 0

34 a

Unclassified Radiological Emergency Preparedness Program (REP)

Three Mile Island Nuclear Generating Station After Action Report/Improvement Plan Table 3.1 - Summary of Exercise Evaluation (Continued. page 9/12)

DATE: 2011-04-12 x

L SITE: Three Mile Island Nuclear Generating Station, PA M: Met, A: ARCA, D: Deficiency, P: Plan Issue, N: Not z J 5 5

0 0

0 0

0 0

0 0

0 0

Demonstrated U U U U U U U U U U Emergency Operations Management Mobilization I al Facilities IbI Direction and Control Ic1 Communications Equipment Idl Equip & Supplies to support operations 1el Protective Action Decision Making Emergency Worker Exposure Control 2al Radiological Assessment and PARs 2bl Decisions for the Plume Phase -PADs 2b2 PADs for protection of special populations 2cl Rad Assessment and Decision making for the Ingestion Exposure Pathway 2dl Rad Assessment and Decision making concerning Relocation, Reentry, and 2el Return Protective Action Implementation Implementation of emergency worker exposure control 3al Implementation of KI decision 3b1 Implementation of protective actions for special populations - EOCs 3c1 Implementation of protective actions for Schools 3c2 M M M M M M M M M M Implementation of traffic and access control 3dl Impediments to evacuation are identified and resolved 3d2 Implementation of ingestion pathway decisions - availability/use of info 3el Materials for Ingestion Pathway PADs are available 3e2 Implementation of relocation, re-entry, and return decisions.

3fl Field Measurement and Analysis Adequate Equipment for Plume Phase Field Measurements 4al Field Teams obtain sufficient information 4a2 Field Teams Manage Sample Collection Appropriately 4a3 Post plume phase field measurements and sampling 4b1 Laboratory operations 4c1 Emergency Notification and Public Info Activation of the prompt alert and notification system 5a1 Activation of the prompt alert and notification system - Fast Breaker 5a2 Activation of prompt alert and notification system-Excptn Areas/Bkup RA 5a3 Emergency information and instructions for the public and the media 5bl Support Operations/Facilities Mon/decon of evacuees and emergency workers, and registration of evacuees 6al Mon/decon of emergency worker equipment 6b I Temporary care of evacuees 6c1 Transportation and treatment of contaminated iniured individuals 6dl 35

4 Unclassified Radiological Emergency Preparedness Program (REP)

Three Mile Island Nuclear Generating Station After Action Report/Improvement Plan Table 311 - Summary of Exercise Evaluation (Continued. page 10/12)

DATE: 2011-04-12 r

d U)

SITE: Three Mile Island Nuclear Generating Station, PA M: Met, A: ARCA, D: Deficiency, P: Plan Issue, N: Not CIO 0

0 0 0

0 0 0 0 0 0 Demonstrated U U U U U U U U U Emergency Operations Management Mobilization lal Facilities 1bi1 Direction and Control 1 l Communications Equipment Id1 Equip & Supplies to support operations lel Protective Action Decision Making Emergency Worker Exposure Control 2al Radiological Assessment and PARs 2b 1 Decisions for the Plume Phase -PADs 2b2 PADs for protection of special populations 2c 1 Rad Assessment and Decision making for the Ingestion Exposure Pathway 2dl Rad Assessment and Decision making concerning Relocation, Reentry, and 2el Return Protective Action Implementation Implementation of emergency worker exposure control 3al Implementation of KI decision 3bl Implementation of protective actions for special populations - EOCs 3c1 Implementation of protective actions for Schools 3c2 M M M M M M M M M M Implementation of traffic and access control 3d]

Impediments to evacuation are identified and resolved 3d2 Implementation of ingestion pathway decisions - availability/use of info 3el Materials for Ingestion Pathway PADs are available 3e2 Implementation of relocation, re-entry, and return decisions.

3fl Field Measurement and Analysis Adequate Equipment for Plume Phase Field Measurements 4al Field Teams obtain sufficient information 4a2 Field Teams Manage Sample Collection Appropriately 4a3 Post plume phase field measurements and sampling 4bl Laboratory operations 4c 1 Emergency Notification and Public Info Activation of the prompt alert and notification system 5al Activation of the prompt alert and notification system - Fast Breaker 5a2 Activation of prompt alert and notification system-Excptn Areas/Bkup RA 5a3 Emergency information and instructions for the public and the media 5b 1 Support Operations/Facilities Mon/decon of evacuees and emergency workers, and registration of evacuees 6al Mon/decon of emergency worker equipment 6b 1 Temporary care of evacuees 6c 1 Transportation and treatment of contaminated injured individuals 6d 1 0

36 a

Unclassified Radiological Emergency Preparedness Program (REP)

Three Mile Island Nuclear Generating Station After Action Report/Improvement Plan Table 3.1 - Summary of Exercise Evaluation (Continued. page 11/12)

DATE: 2011-04-12 SITE: Three Mile Island Nuclear Generating Station, PA U z z

ri rdý C)~ M d

C2 a)2 Cý C) r0 M: Met, A: ARCA, D: Deficiency, P: Plan Issue, N: Not U U U U C. C 44 Z Z Demonstrated U U U U U U U U U Emergency Operations Management Mobilization 1 al Facilities IbI Direction and Control ici Communications Equipment 1dl Equip & Supplies to support operations lel Protective Action Decision Making Emergency Worker Exposure Control 2al Radiological Assessment and.PARs 2bl Decisions for the Plume Phase -PADs 2b2 PADs for protection of special populations 2cl Rad Assessment and Decision making for the Ingestion Exposure Pathway 2dl Rad Assessment and Decision making concerning Relocation, Reentry, and 2el Return Protective Action Implementation Implementation of emergency worker exposure control 3al Implementation of KI decision 3b1 Implementation of protective actions for special populations - EOCs 3c1 Implementation of protective actions for Schools 3c2 M M M M M M M M M M Implementation of traffic and access control 3dl Impediments to evacuation are identified and resolved 3d2 Implementation of ingestion pathway decisions - availability/use of info 3el' Materials for Ingestion Pathway PADs are available 3e2 Implementation of relocation, re-entry, and return decisions.

3fH Field Measurement and Analysis Adequate Equipment for Plume Phase Field Measurements 4al Field Teams obtain sufficient information 4a2 Field Teams Manage Sample Collection Appropriately 4a3 Post plume phase field measurements and sampling 4bl Laboratory operations 4c0 Emergency Notification and Public Info Activation of the prompt alert and notification system 5al Activation of the prompt alert and notification system - Fast Breaker 5a2 Activation of prompt alert and notification system-Excptn Areas/Bkup RA 5a3 Emergency information and instructions for the public and the media 5bl Support Operations/Facilities Mon/decon of evacuees and emergency workers, and registration of evacuees 6al Mon/decon of emergency worker equipment 6b 1 Temporary care of evacuees 6c 1 Transportation and treatment of contaminated iniured individuals 6dI 37

a Unclassified Radiological Emergency Preparedness Program (REP)

Three Mile Island Nuclear Generating Station After Action Report/Improvement Plan Table 3.1 - Summary of Exercise Evaluation (Continued. page 12/12)

DATE: 2011-04-12 W U SITE: Three Mile Island Nuclear Generating Station, PA U

z Q/

CC) C)~

rAr M: Met, A: ARCA, D: Deficiency, P: Plan Issue, N: Not w

  • Demonstrated U U U U U U U U U Emergency Operations Management Mobilization 1 al Facilities IbI Direction and Control ici Communications Equipment Id1 Equip & Supplies to support operations lel Protective Action Decision Making Emergency Worker Exposure Control 2al Radiological Assessment and PARs 2bl Decisions for the Plume Phase -PADs 2b2 PADs for protection of special populations 2c 1 Rad Assessment and Decision making for the Ingestion Exposure Pathway 2dl Rad Assessment and Decision making concerning Relocation, Reentry, and 2el Return Protective Action Implementation Implementation of emergency worker exposure control 3al Implementation of KI decision 3bl Implementation of protective actions for special populations - EOCs 3c1 Implementation of protective actions for Schools 3c2 M M M M M M M M M Implementation of traffic and access control 3d1 Impediments to evacuation are identified and resolved 3d2 Implementation of ingestion pathway decisions - availability/use of info 3e1 Materials for Ingestion Pathway PADs are available 3e2 Implementation of relocation, re-entry, and return decisions.

3f1 Field Measurement and Analysis Adequate Equipment for Plume Phase Field Measurements 4al Field Teams obtain sufficient information 4a2 Field Teams Manage Sample Collection Appropriately 4a3 Post plume phase field measurements and sampling 4bl Laboratory operations 4c 1 Emergency Notification and Public Info Activation of the prompt alert and notification system 5al Activation of the prompt alert and notification system - Fast Breaker 5a2 Activation of prompt alert and notification system-Excptn Areas/Bkup RA 5a3 Emergency information and instructions for the public and the media 5bl Support Operations/Facilities Mon/decon of evacuees and emergency workers, and registration of evacuees 6al M

Mon/decon of emergency worker equipment 6b 1 Temporary care of evacuees 6c1 M

Transportation and treatment of contaminated injured individuals 6d 1 a

38 0

Unclassified Radiological Emergency Preparedness Program (REP)

After Action Report/Improvement Plan Three Mile Island Nuclear Generating Station 3.3 Criteria Evaluation Summaries 3.3.1 Pennsylvania Jurisdictions 3.3.1.1 Pennsylvania Emergency Operations Center

a.

MET: 1.a. 1, 1.c. 1, 1.d. 1, 1.e. 1, 2.b.2, 3.b. 1, 3.d. 1, 3.d.2, 5.a. 1.

b.

AREAS REQUIRING CORRECTIVE ACTION: None

c.

DEFICIENCY: None

d. PLAN ISSUES: None
e.

NOT DEMONSTRATED: None

f.

PRIOR ISSUES:- RESOLVED: None

g. PRIOR ISSUES - UNRESOLVED: None 3.3.1.2 Pennsylvania Joint Information Center
a.

MET: 1.d.1,5.a.1,5.b.1.

b.

AREAS REQUIRING CORRECTIVE ACTION: None

c.

DEFICIENCY: None

d. PLAN ISSUES: None
e.

NOT DEMONSTRATED: None

f.

PRIOR ISSUES - RESOLVED: None

g. PRIOR ISSUES - UNRESOLVED: None 3.3.1.3 Pennsylvania Accident Assessment Center, State Emergency Operations Center-Bureau of Radiation Protection
a.

MET: 1.a. 1, 1.c. 1, 1.d. 1,.e. 1, 2.a. 1, 2.b. 1.

b.

AREAS REQUIRING CORRECTIVE ACTION: None

c.

DEFICIENCY: None

d. PLAN ISSUES: None
e. NOT DEMONSTRATED: None
f.

PRIOR ISSUES - RESOLVED: None

g. PRIOR ISSUES - UNRESOLVED: None 39

Unclassified Radiological Emergency Preparedness Program (REP)

After Action Report/Improvement Plan Three Mile Island Nuclear Generating Station 3.3.1.4 Pennsylvania State Traffic and Access Control Points, State Police Barracks Harrisburg

a.

MET: 1.d. 1, 1.e. 1, 3.a. 1, 3.b. 1, 3.d. 1; 3.d.2.

b. AREAS REQUIRING CORRECTIVE ACTION: None
c.

DEFICIENCY: None

d. PLAN ISSUES: None
e.

NOT DEMONSTRATED: None

f.

PRIOR ISSUES - RESOLVED: None

g. PRIOR ISSUES - UNRESOLVED: None 3.3.2 Risk Jurisdictions 3.3.2.1 Cumberland County Emergency Operations Center
a.

MET: 1.a. 1, 1.c. 1, 1.d. 1, 1.e. 1, 2.a. 1, 2.c. 1, 3.a. 1, 3.b. 1, 3.c. 1, 3.c.2, 3.d. 1, 3.d.2, 5.a. 1, 5.b.1.

b. AREAS REQUIRING CORRECTIVE ACTION: None
c.

DEFICIENCY: None

d. PLAN ISSUES: None
e.

NOT DEMONSTRATED: None

f.

PRIOR ISSUES - RESOLVED: None

g. PRIOR ISSUES - UNRESOLVED: None 3.3.2.2 Cumberland County Emergency Worker Monitoring and Decontamination Station, West Shore Fire Station #2, Lemoyne
a.

MET: 1.e.1,3.a.1,6.a.1,6.b.1.

b. AREAS REQUIRING CORRECTIVE ACTION: None
c.

DEFICIENCY: None

d. PLAN ISSUES: None
e.

NOT DEMONSTRATED: None

f.

PRIOR ISSUES - RESOLVED: None

g. PRIOR ISSUES - UNRESOLVED: None 40

Unclassified Radiological Emergency Preparedness Program (REP)

After Action Report/Improvement Plan Three Mile Island Nuclear Generating Station 3.3.2.3 Cumberland County Reception Center, Big Spring High School

a.

MET: 1.e.1, 6.a.1.

b.

AREAS REQUIRING CORRECTIVE ACTION: None

c.

DEFICIENCY: None

d. PLAN ISSUES: None
e.

NOT DEMONSTRATED: None

f.

PRIOR ISSUES - RESOLVED: None

g. PRIOR ISSUES - UNRESOLVED: None 3.3.2.4 Cumberland County Monitoring and Decontamination Center, Big Spring High School
a.

MET: 1.e.1, 3.a.1, 6.a.1.

b. AREAS REQUIRING CORRECTIVE ACTION: None
c.

DEFICIENCY: None

d. PLAN ISSUES: None
e.

NOT DEMONSTRATED: None

f.

PRIOR ISSUES - RESOLVED: None

g. PRIOR ISSUES - UNRESOLVED: None 3.3.2.5 Cumberland County, New Cumberland Borough Emergency Operations Center
a.

MET: 1.a.1, 1.c.1, 1.d.1, 1.e.1, 2.c.1, 3.a.I, 3.b.1, 3.c.1, 3.c.2, 3.d.1, 3.d.2, 5.a.1, 5.a.3.

b. AREAS REQUIRING CORRECTIVE ACTION: None
c.

DEFICIENCY: None

d. PLAN ISSUES: None
e.

NOT DEMONSTRATED: None

f.

PRIOR ISSUES - RESOLVED: None

g.

PRIOR ISSUES - UNRESOLVED: None 3.3.2.6 Cumberland County, New Cumberland Borough Back-up Route Alerting

a.

MET: 1.d.1, 1.e.1, 3.a.1, 3.b.1, 5.a.3.

b.

AREAS REQUIRING CORRECTIVE ACTION: None

c.

DEFICIENCY: None

d. PLAN ISSUES: None
e.

NOT DEMONSTRATED: None

f.

PRIOR ISSUES - RESOLVED: None 41

Unclassified Radiological Emergency Preparedness Program (REP)

After Action Report/Improvement Plan Three Mile Island Nuclear Generating Station

g.

PRIOR ISSUES - UNRESOLVED: None 3.3.2.7 Dauphin County Emergency Operations Center

a.

MET: 1.a. 1, 1.c. 1, 1.d. 1, 1.e. 1, 2.a. 1, 2.c. 1, 3.a. 1, 3.b. 1, 3.c. 1, 3.c.2, 3.d. 1, 3.d.2, 5.a. 1, 5.b.1.

b.

AREAS REQUIRING CORRECTIVE ACTION: None

c.

DEFICIENCY: None

d. PLAN ISSUES: None
e. NOT DEMONSTRATED: None
f. PRIOR ISSUES - RESOLVED: None
g. PRIOR ISSUES - UNRESOLVED: None 3.3.2.8 Dauphin County Emergency Worker Monitoring and Decontamination Station, Harrisburg Area Community College
a.

MET: 1.e.1, 3.a.1, 6.a.1, 6.b.1.

b. AREAS REQUIRING CORRECTIVE ACTION: None
c.

DEFICIENCY: None

d. PLAN ISSUES: None
e.

NOT DEMONSTRATED: None

f.

PRIOR ISSUES - RESOLVED: None

g. PRIOR ISSUES - UNRESOLVED: None 3.3.2.9 Dauphin County Mass Care Center, Lenkerville Elementary School
a.

MET: 1.e.1,6.a.1,6.c.1.

b. AREAS REQUIRING CORRECTIVE ACTION: None
c.

DEFICIENCY: None

d. PLAN ISSUES: None
e.

NOT DEMONSTRATED: None

f.

PRIOR ISSUES - RESOLVED: None

g. PRIOR ISSUES - UNRESOLVED: None 42

Unclassified Radiological Emergency Preparedness Program (REP)

After Action ReportlImprovement Plan Three Mile Island Nuclear Generating Station 3.3.2.10 Dauphin County Mass Care Center, Halifax Area High School

a.

MET: 1.e.1, 6.a.1, 6.c.1.

b.

AREAS REQUIRING CORRECTIVE ACTION: None

c.

DEFICIENCY: None

d.

PLAN ISSUES: None

e. NOT DEMONSTRATED: None
f.

PRIOR ISSUES - RESOLVED: None

g. PRIOR ISSUES - UNRESOLVED: None 3.3.2.11 Dauphin County, Harrisburg City Emergency Operations Center
a.

MET: 1.a. 1, 1.c. 1, 1.d. 1, 1.e. 1, 2.c. 1, 3.a. 1, 3.b. I, 3.c. 1, 3.d. 1, 3.d.2, 5.a. 1.

b.

AREAS REQUIRING CORRECTIVE ACTION: None

c.

DEFICIENCY: None

d. PLAN ISSUES: None
e.

NOT DEMONSTRATED: None

f.

PRIOR ISSUES - RESOLVED: None

g. PRIOR ISSUES - UNRESOLVED: None 3.3.2.12 Dauphin County, Highspire Borough Emergency Operations Center
a.

MET: L.a.1, 1.c.1, 1.d.1, L.e.1, 2.c.1, 3.a.1, 3.b.1, 3.c.1, 3.d.1, 3.d.2, 5.a.3.

b. AREAS REQUIRING CORRECTIVE ACTION: None
c.

DEFICIENCY: None

d. PLAN ISSUES: None,
e.

NOT DEMONSTRATED: None

f.

PRIOR ISSUES - RESOLVED: None

g. PRIOR ISSUES - UNRESOLVED: None 3.3.2.13 Dauphin County, Highspire Back-up Route Alerting
a.

MET: 1.d.1, 1.e.1, 3.a.1, 3.b.1, 5.a.3.

b. AREAS REQUIRING CORRECTIVE ACTION: None
c.

DEFICIENCY: None

d. PLAN ISSUES: None
e.

NOT DEMONSTRATED: None

f.

PRIOR ISSUES - RESOLVED: None

g.

PRIOR ISSUES - UNRESOLVED: None 43

Unclassified Radiological Emergency Preparedness Program (REP)

After Action Report/Improvement Plan Three Mile Island Nuclear Generating Station 3.3.2.14 Dauphin County, Londonderry Township Emergency Operations Center

a.

MET: 1.a. l, 1.c. 1, 1.d. l, 1.e. 1, 2.c. 1, 3.a. 1, 3.b. l, 3.c. l, 3.d. l, 3.d.2, 5.a. 1.

b.

AREAS REQUIRING CORRECTIVE ACTION: None

c.

DEFICIENCY: None

d. PLAN ISSUES: 3.a.I.

ISSUE NO.: 64-11-3al-P-01 CRITERION: OROs issue appropriate dosimetry and procedures, and manage radiological exposure to emergency workers IAW plans and procedures. Emergency workers periodically and at the end of each mission read and record dosimeter reading. (NUREG-0654, K.3)

CONDITION: Direct-reading dosimeters and Dosimetry - KI Report Forms were not provided to Emergency Operations Center (EOC). staff for monitoring radiation exposure within the Londonderry Township EOC.

POSSIBLE CAUSE: There is no specific reference in the Londonderry Township Supplement to the Dauphin County Radiological Emergency Response Procedures/Radiological Officer's checklist to create an Area Monitoring kit, along with the specific equipment necessary.

REFERENCE:

NUREG-0654, K..3.and K.3.b; Commonwealth of Pennsylvania, Annex A, Appendix 4, page A-4-3.

EFFECT: Any radiation dose received by the occupants of the Londonderry Township EOC would not be identified until the permanent record dosimeters were processed.

CORRECTIVE ACTION DEMONSTRATED: Londonderry Township revised their Supplement to the Dauphin County Radiological Emergency Response Procedures/Radiological Officer's checklist to require tracking exposure by the use of area DRDs and the Dosimetry - KI Report Form. The Township also revised the EMD's Checklist to reflect his/her oversight of the process.

44

Unclassified Radiological Emergency Preparedness Program (REP)

After Action Report/Improvement Plan Three Mile Island Nuclear Generating Station

e.

NOT DEMONSTRATED: None

f.

PRIOR ISSUES - RESOLVED: None

g. PRIOR ISSUES - UNRESOLVED: None 3.3.2.15 Dauphin County, Paxtang Borough Emergency Operations Center
a.

MET: 1.a.1, 1.c.1, 1.d.1, 1.e.1, 2.c.1, 3.a.1, 3.b.1, 3.c.1, 3.d.1, 3.d.2, 5.a.1.

b. AREAS REQUIRING CORRECTIVE ACTION: None
c.

DEFICIENCY: None

d. PLAN ISSUES: None
e.

NOT DEMONSTRATED: None

f.

PRIOR ISSUES - RESOLVED: None

g. PRIOR ISSUES - UNRESOLVED: None 3.3.2.16 Dauphin County, LowerPaxton Township Emergency Operations Center
a.

MET: 1.a.1, 1.c.1, 1.d.1, 1.e.1, 2.c.1, 3.a. 1, 3.b.1, 3.c.1, 3.d.1, 3.d.2, 5.a.1.

b. AREAS REQUIRING CORRECTIVE ACTION: 3.c.1.

ISSUE NO.: 64-11-3cl-A-01 CRITERION: PADs are implemented for special population groups within areas subject to protective actions. (NUREG-0654, E.7., J.9., 10.c.d.e.g)

CONDITION: Lower Paxton Township (LPT) did not request buses for transportation-dependent individuals during the Alert.

POSSIBLE CAUSE: LPT did not follow the information contained in their plan. The plan identifies that 144 transportation-dependent individuals need three buses to evacuate and this equipment is an unmet need. The Transportation Officer's standard operating procedure (SOP) calls for a request for buses to be made from the LPT to the Dauphin County Emergency Operations Center (EOC) during the Alert. The unmet need was not communicated to Dauphin County.

REFERENCE:

NUREG-0654, J. 1O.d; NUREG-0654, J. 10.g; LPT supplement to the Dauphin County Radiological Emergency Response Procedures and the SOP for the LPT Transportation Officer.

45

Unclassified Radiological Emergency Preparedness Program (REP),

After Action Report/Improvement Plan Three Mile Island Nuclear Generating Station EFFECT: Approximately 144 transportation-dependent individuals might not have been evacuated in a timely manner.

CORRECTIVE ACTION DEMONSTRATED: At approximately 1956 hours0.0226 days <br />0.543 hours <br />0.00323 weeks <br />7.44258e-4 months <br /> during the Site Area Emergency, the LPT Emergency Management Coordinator (EMC) requested three buses from Dauphin County Emergency Management Agency (DEMA). DEMA called back at approximately 2012 hours0.0233 days <br />0.559 hours <br />0.00333 weeks <br />7.65566e-4 months <br />, and indicated the buses would be provided. The buses arrived at the LPT EOC at approximately 2037 hours0.0236 days <br />0.566 hours <br />0.00337 weeks <br />7.750785e-4 months <br />.

The bus drivers were given an emergency worker briefing and told to standby.

c.

DEFICIENCY: None

d.

PLAN ISSUES: None

e.

NOT DEMONSTRATED: None

f.

PRIOR ISSUES - RESOLVED: None

g.

PRIOR ISSUES - UNRESOLVED: None 3.3.2.17 Dauphin County, South Hanover Township Emergency Operations Center

a.

M ET: 1.a.1, l.c.1, 1.d.1, 1.e.1, 2.c.1, 3.a.1, 3.b.1, 3.c.1, 3.d.1, 3.d.2, 5.a.1.

b.

AREAS REQUIRING CORRECTIVE ACTION: None

c.

DEFICIENCY: None

d.

PLAN ISSUES: None

e.

NOT DEMONSTRATED: None

f.

PRIOR ISSUES - RESOLVED: None

g.

PRIOR ISSUES - UNRESOLVED: None 3.3.2.18 Lancaster County Emergency Operations Center

a.

MET: 1.c.1,3.a.l.

b. AREAS REQUIRING CORRECTIVE ACTION: 1.c.1.

ISSUE NO.: 64-11-1cl-A-02 CRITERION: Key personnel with functional roles for the ORO provide direction and control to that part of the overall response effort for which they are responsible.

CONDITION: The Lancaster County did not timely alert the Conoy Township Route 46

Unclassified Radiological Emergency Preparedness Program (REP)

After Action Report/Improvement Plan Three Mile Island Nuclear Generating Station Alerting (RA) teams.

POSSIBLE CAUSE: The Lancaster County Radiological Emergency Response Procedures requires the RA teams be placed on standby status at an Alert ECL (the procedure specifically lists the fire departments affected during an incident at TMI).

The Lancaster County procedures read as if this should be accomplished as an automatic action and does not indicate that Lancaster. County should wait until requested by.Conoy Township. If Lancaster. County procedures were implemented as written, there would not have been the delay in the fire fighters reporting to the Conoy EOC (Bainbridge Fire Department). If the delay in placing RA teams was eliminated, the task and radiological briefings would have been completed prior to the siren failure at Site Area Emergency. If teams were fully briefed and ready to leave the EOC at Site Area Emergency, they may have been able to complete their route within the designated 45 minutes.

REFERENCE:

NUREG-0654, F. 1.e;Lancaster County RERP, and Master Checklist.

EFFECT: TheConoy Township did not complete'the Route Alerting within 45 minutes.

CORRECTIVE ACTION DEMONSTRATED: Lancaster County adequately demonstrated the ability to place RA teams on standby status at an Alert ECL.

c.

DEFICIENCY: None

d. PLAN ISSUES: None
e.

NOT DEMONSTRATED: 1.a.1, 1.d.1, 1.e.l, 2.a.1, 2.c.1, 3.b.1, 3.c.1, 3.c.2, 3.d.l, 3.d.2, 5.a.1, 5.a.3, 5.b.1.

f.

PRIOR ISSUES - RESOLVED: None

g. PRIOR ISSUES - UNRESOLVED: None 3.3.2.19 Lancaster County Emergency Worker Monitoring and Decontamination Station, Mount Joy Fire Department
a. MET: 1.e.1, 3.a.1, 6.a.1, 6.b.1.
b. AREAS REQUIRING CORRECTIVE ACTION: None
c.

DEFICIENCY: None 47

Unclassified Radiological Emergency Preparedness Program (REP)

After'Action Report/Improvement Plan Three Mile Island Nuclear Generating Station

d. PLAN ISSUES: None
e.

NOT DEMONSTRATED: None

f.

PRIOR ISSUES - RESOLVED: None

g. PRIOR ISSUES - UNRESOLVED: None 3.3.2.20 Lancaster County Mass Care Center Conestoga Valley High School
a.

MET: 1.b.1, 6.a.1, 6.c.1.

b. AREAS REQUIRING CORRECTIVE ACTION: None
c.

DEFICIENCY: None

d. PLAN ISSUES: None
e.

NOT DEMONSTRATED: None

f.

PRIOR ISSUES - RESOLVED: None

g. PRIOR ISSUES - UNRESOLVED: None 3.3.2.21 Lancaster County Mass Care Center, Conestoga Valley Middle School
a.

MET: 1.b.1,6.a.1,6.c.1.

b. AREAS REQUIRING CORRECTIVE ACTION: None
c.

DEFICIENCY: None

d. PLAN ISSUES: None
e.

NOT DEMONSTRATED: None

f.

PRIOR ISSUES - RESOLVED: None

g. PRIOR ISSUES - UNRESOLVED: None 3.3.2.22 Lancaster County Reception Center, Park City Mall
a.

MET: 1.d. 1, 1.e. 1, 3.d.1.

b.

AREAS REQUIRING CORRECTIVE ACTION: None

c.

DEFICIENCY: None

d. PLAN ISSUES: None
e.

NOT DEMONSTRATED: None

f.

PRIOR ISSUES - RESOLVED: None

g. PRIOR ISSUES - UNRESOLVED: None 48

Unclassified Radiological Emergency Preparedness Program (REP)

After Action Report/Improvement Plan Three Mile Island Nuclear Generating Station 3.3.2.23 Lancaster County Monitoring and Decontamination Center, Manheim Township School Complex

a.

MET: 1.e.1, 3.a.1, 6.a.1.

b.

AREAS REQUIRING CORRECTIVE ACTION: None

c.

DEFICIENCY: None

d.

PLAN ISSUES: None

e.

NOT DEMONSTRATED: None

f.

PRIOR ISSUES - RESOLVED: None

g. PRIOR ISSUES - UNRESOLVED: Norie 3.3.2.24 Lancaster County Mass Care Center,Cocalico Middle School
a.

MET: 1.b.1, 6.a.1, 6.c.1.

b.

AREAS REQUIRING CORRECTIVE ACTION: None

c.

DEFICIENCY: None

d. PLAN ISSUES: None
e.

NOT DEMONSTRATED: None

f.

PRIOR ISSUES - RESOLVED: None

g. PRIOR ISSUES - UNRESOLVED: None 3.3.2.25 Lancaster County, Cocalico High School,Mass Care Center
a.

MET: 1.b.1, 6.a.1, 6.c.1.

b. AREAS REQUIRING CORRECTIVE ACTION: None
c.

DEFICIENCY: None

d. PLAN ISSUES: None
e.

NOT DEMONSTRATED: None

f.

PRIOR ISSUES - RESOLVED: None

g. PRIOR ISSUES - UNRESOLVED: None 3.3.2.26 Lancaster County Mass Care Center, Manheim Township Middle School
a.

MET: 1.b.1, 6.a.1, 6.c.1.

b. AREAS REQUIRING CORRECTIVE ACTION: None
c.

DEFICIENCY: None

d. PLAN ISSUES: None
e.

NOT DEMONSTRATED: None

f.

PRIOR ISSUES - RESOLVED: None 49

Unclassified Radiological Emergency Preparedness Program' (REP)

After Action Report/Improvement Plan Three Mile Island Nuclear Generating Station

g. PRIOR ISSUES - UNRESOLVED: None 3.3.2.27 Lancaster County Mass Care Center, Warwick High School
a.

MET: 1.b.1, 6.a.1, 6.c.1.

b. AREAS REQUIRING CORRECTIVE ACTION: None
c.

DEFICIENCY: None

d. PLAN ISSUES: None
e. NOT DEMONSTRATED: None
f.

PRIOR ISSUES - RESOLVED: None

g. PRIOR ISSUES - UNRESOLVED: None 3.3.2.28 Lancaster County Mass Care Center, Warwick Middle School
a.

MET: 1.b.1, 6.a.1, 6.c.1.

b.

AREAS REQUIRING CORRECTIVE ACTION: None

c.

DEFICIENCY: None

d.

PLAN ISSUES: None

e.

NOT DEMONSTRATED: None

f.

PRIOR ISSUES - RESOLVED: None

g.

PRIOR ISSUES - UNRESOLVED: None 3.3.2.29 Lancaster County, Conoy Township Emergency Operations Center

a.

MET: 3.a.1.

b. AREAS REQUIRING CORRECTIVE ACTION: None
c.

DEFICIENCY: None

d. PLAN ISSUES: None
e.

NOT DEMONSTRATED: None

f.

PRIOR ISSUES - RESOLVED: 3.a.1.

ISSUE NO.: 64-09-3al-A-03 ISSUE: The backup route alerting team members were receiving a radiological brief and being issued dosimetry when the notification of a failed siren was received at the Conoy Emergency Operations Center, delaying the start of their runs for 15 minutes.

CORRECTIVE ACTION DEMONSTRATED: On May 2, 2011, re-demonstration of the Conoy Township Backup Route Alerting was conducted at Bainbridge Fire 50 4

Unclassified Radiological Emergency Preparedness Program (REP)

After Action Report/improvement Plan Three Mile Island Nuclear Generating Station Department, Conoy Township, Lancaster County. A series of injects simulating an incident at Three Mile Island Nuclear Generating Station were communicated from Lancaster County Department of Public Safety beginning at Alert (1830 hours0.0212 days <br />0.508 hours <br />0.00303 weeks <br />6.96315e-4 months <br />),

escalated to Site Area Emergency at 1845 with an announcement of a siren sounding and activation of the Emergency Alert System. Upon receipt of the Alert notification, the Conoy Township Deputy Emergency Management Coordinator (EMC) mustered his Emergency Operations Center staff, briefed them on the incident at hand, and informed the Radiological Officer (RO); to.p'repare the Backup Route Alerting Teams for a potential mission. The Radiological Officer explained the appropriate procedure for issuing of dosimetry, Potassium Iodide (KI), proper wear of dosimetry, protective gear, and answered a series of questions relating to radiological protective measures. The RO conducted a thorough and accurate briefing to Two-(2) man Route Alerting Teams.

At approximately 1856 hours0.0215 days <br />0.516 hours <br />0.00307 weeks <br />7.06208e-4 months <br />, the Deputy EMC was contacted and informed that siren number 410 had failed and took immediate measures to brief the two Route Alerting Teams on their specific routes (Route B), issued maps, and provided specific instructions on the conduct of Route Alerting, notification of hearing impaired, and announcements to the General Public. The members of the Bainbridge Fire Department Route Alerting Team completed the route within 43-minutes of notifications and demonstrated appropriate Route Alerting and drill protocols throughout the exercise.

All activities were based on the plans and procedures and completed as they would have been in an actual emergency except as noted in the extent of play agreement.

g.

PRIOR ISSUES - UNRESOLVED: None 3.3.2.30 Lancaster County, Conoy Township Back-Up Route Alerting

a.

MET: 3.a.1, 5.a.3.

b.

AREAS REQUIRING CORRECTIVE ACTION: None

c.

DEFICIENCY: None

d. PLAN ISSUES: None
e. NOT DEMONSTRATED: None
f.

PRIOR ISSUES - RESOLVED: None 51

Unclassified Radiological Emergency Preparedness Program (REP)

After Action Report/Improvement Plan Three Mile Island Nuclear Generating Station

g.

PRIOR ISSUES - UNRESOLVED: None 3.3.2.31 Lancaster County, East Donegal Township Emergency Operation Center

a.

M ET: 1.a.1, 1.c.1, 1.d.1, 1.e.1, 2.c.1, 3.a.1, 3.b.1, 3.c.1, 3.d.1, 3.d.2, 5.a.1, 5.a.3.

b.

AREAS REQUIRING CORRECTIVE ACTION: None

c.

DEFICIENCY: None

d.

PLAN ISSUES: None

e.

NOT DEMONSTRATED: None

f.

PRIOR ISSUES - RESOLVED: None

g.

PRIOR ISSUES - UNRESOLVED: None 3.3.2.32 Lancaster County, East Donegal Township Back-up Route Alerting

a.

MET: 1.a. 1, 1.d. 1, 1.e. 1, 3.a. 1, 3.b. 1, 5.a. 1, 5.a.3.

b.

AREAS REQUIRING CORRECTIVE ACTION: None

c.

DEFICIENCY: None

d.

PLAN ISSUES: None

e.

NOT DEMONSTRATED: None

f.

PRIOR ISSUES - RESOLVED: None

g.

PRIOR ISSUES - UNRESOLVED: None 3.3.2.33 Lancaster County, Elizabethtown Borough/West Donegal Township/Mount Joy Township Emergency Operations Center

a.

MET: 1.a. 1, 1.c. 1, 1.d. 1, 1.e. 1, 2.c. 1, 3.a. 1, 3.b. 1, 3.c. 1, 3.d. 1, 3.d.2, 5.a. 1.

b.

AREAS REQUIRING CORRECTIVE ACTION: None

c.

DEFICIENCY: None

d.

PLAN ISSUES: None

e.

NOT DEMONSTRATED: None

f.

PRIOR ISSUES - RESOLVED: None'

g.

PRIOR ISSUES - UNRESOLVED: None 3.3.2.34 Lancaster County, Elizabethtown Borough Traffic and Access Control

a.

MET: 1.d. 1, 1.e. 1, 3.a. 1, 3.b. 1, 3.d. 1, 3.d.2.

b. AREAS REQUIRING CORRECTIVE ACTION: None
c.

DEFICIENCY: None

d.

PLAN ISSUES: None 52 is

Unclassified Radiological Emergency Preparedness Program (REP)

After Action ReportlImprovement Plan Three Mile Island Nuclear Generating Station

e.

NOT DEMONSTRATED: None

f.

PRIOR ISSUES - RESOLVED: None

g. PRIOR ISSUES - UNRESOLVED: None 3.3.2.35 Lancaster County, Susquehanna Regional Police Department Traffic and Access Control a,

MET: 1.d.1, 1.e.1, 3.a.1, 3.b.1, 3.d.1, 3.d.2.

b.

AREAS REQUIRING CORRECTIVE ACTION: None c,

DEFICIENCY: None

d. PLAN ISSUES: None e,

NOT DEMONSTRATED: None

f.

PRIOR ISSUES - RESOLVED: None

g. PRIOR ISSUES - UNRESOLVED: None 3.3.2.36 Lebanon County Emergency Operations Center
a.

MET: 1.a.1, 1.c.1, 1.d.1, Le.1, 2.a.1, 2.c.1, 3.a.1, 3.b.1, 3.c.1, 3.c.2, 3.d.1, 3.d.2, 5.a.1, 5.a.3, 5.b. 1.

b. AREAS REQUIRING CORRECTIVE ACTION: None
c.

DEFICIENCY: None

d. PLAN ISSUES: None
e.

NOT DEMONSTRATED: None

f.

PRIOR ISSUES - RESOLVED: None

g. PRIOR ISSUES - UNRESOLVED: None 3.3.2.37 Lebanon County Emergency Worker Monitoring and Decontamination Station, Annville Union Hose Fire Department
a.

MET: 1.e.1,3.a.1,6.a.1,6.b.1.

b. AREAS REQUIRING CORRECTIVE ACTION: 1.e.1.

ISSUE NO.: 64-11-1el-A-03 CRITERION: Equipment, maps, displays, dosimetry, potassium iodide (KI), and other supplies are sufficient to support emergency operations.

CONDITION: There was no evidence that the Bicron Surveyor 2000 and Ludlum Model 2241-2 contamination survey instruments had a source check "range of 53

Unclassified Radiological Emergency Preparedness Program (REP)

After Action Report/Improvement Plan Three Mile Island Nuclear Generating Station readings" acceptance criteria to ensure instrument operability (either affixed to the instrument or available by other means).

POSSIBLE CAUSE: A 1 microcurie Cesium 137 source was available to check handheld survey instruments' operability; however no acceptance criteria was available to determine if the instrument responded properly to the radioactive check source. The licensee controller indicated that instruments were being calibrated by a new provider. If the calibration provider is responsible for determining the source check range, they may not be aware of this responsibility. If it is not the calibration facility's responsibility then the County should determine these ranges after receipt back from calibration and identify the ranges on each instrument along with the source to be used.

REFERENCE:

NUREG-0654, H. 10; Lebanon County Emergency Operations Plan, Annex E, Appendix 13, Radiological Exposure Control (ESF 10), December 2008; ANSI N323A, 1997, American National Standard Radiation Protection Instrumentation Test and Calibration, Portable Survey Instruments, Section 4.8, Source Response Check EFFECT: If the instrument does not appropriately respond to predetermined value when using a specific source, the user cannot be ensured that the instrument measures contamination properly. If the instrument under responds, an emergency worker or their equipment may be incorrectly released as clean (free from contamination).

CORRECTIVE ACTION DEMONSTRATED: Lebanon County successfully re-demonstrated this ARCA by providing the required information on the hand-held radiological instruments. The stickers and hand-held radiological instruments were photographed and sent to FEMA.

c.

DEFICIENCY: None

d. PLAN ISSUES: None
e. NOT DEMONSTRATED: None
f.

PRIOR ISSUES - RESOLVED: None

g. PRIOR ISSUES - UNRESOLVED: None 54 a

Unclassified Radiological Emergency Preparedness Program (REP)

After Action Report/Improvement Plan Three Mile Island Nuclear Generating Station 3.3.2.38 Lebanon County Reception Center, Lebanon County Career and Technological Center

a.

MET: 1.d.1, 1.e. 1, 3.d.1.

b.

AREAS REQUIRING CORRECTIVE ACTION: None

c.

DEFICIENCY: None

d. PLAN ISSUES: None
e. NOT DEMONSTRATED: None
f.

PRIOR ISSUES - RESOLVED: None

g. PRIOR ISSUES - UNRESOLVED: None 3.3.2.39 Lebanon County Monitoring and Decontamination Center, Lebanon County Career and Technological Center
a.

MET: L.e.1, 3.a.1, 6.a.1.

b. AREAS REQUIRING CORRECTIVE ACTION: 1.e.1.

ISSUE NO.: 64-1 1-1el-A-04 CRITERION: Equipment, maps, displays, dosimetry, potassium iodide (KI), and other supplies are sufficient to support emergency operations.

CONDITION: The hand-held radiological instruments issued to radiation monitoring personnel at the Lebanon County Monitoring and Decontamination Center were not provided with stickers or other information showing the acceptable range of instrument response during pre-use source checks.

POSSIBLE CAUSE: The director of the Lebanon County Monitoring and Decontamination Center stated that stickers had been applied to instruments in the past to provide this information but the stickers were removed by the calibration laboratory and were not replaced when the units were calibrated.

REFERENCE:

NUREG-0654,Section II.H Emergency Facilities and Equipment EFFECT: Radiation monitors performing pre-use operational checks of the instruments were not able to verify that the instruments were responding within an acceptable range of values.

55

Unclassified Radiological Emergency Preparedness Program (REP).

After Action Report/Improvement Plan Three Mile Island Nuclear Generating Station CORRECTIVE ACTION DEMONSTRATED: Lebanon County successfully re-demonstrated this ARCA by providing the required information on the hand-held radiological instruments. The stickers and hand-held radiological instruments were photographed and sent to FEMA.

c.

DEFICIENCY: None

d. PLAN ISSUES: None
e.

NOT DEMONSTRATED: None

f.

PRIOR ISSUES - RESOLVED: None

g. PRIOR ISSUES - UNRESOLVED: None 3.3.2.40 Lebanon County Mass Care Center, Northern Lebanon High School
a.

MET:, 1.e.1, 6.a.1, 6.c.1.

b. AREAS REQUIRING CORRECTIVE ACTION: None
c.

DEFICIENCY: None

d. PLAN ISSUES: None
e.

NOT DEMONSTRATED: None

f.

PRIOR ISSUES - RESOLVED: None

g.

PRIOR ISSUES - UNRESOLVED: None 3.3.2.41 Lebanon County, South Londonderry Township Emergency Operations Center

a.

MET: L.a. 1, 1.c. 1, 1.d. 1, L.e. 1, 3.a. 1, 3.c. 1, 3.d. 1, 3.d.2, 5.a. 1, 5.a.3.

b.

AREAS REQUIRING CORRECTIVE ACTION: None

c.

DEFICIENCY: None

d. PLAN ISSUES: None
e. NOT DEMONSTRATED: 2.c.1, 3.b.1.
f.

PRIOR ISSUES - RESOLVED: None

g. PRIOR ISSUES - UNRESOLVED: None 3.3.2.42 Lebanon County, South Londonderry Township, Back-Up Route Alerting
a.

MET: 1.d.1, 1.e.1, 3.a.1, 3.b.1, 5.a.3.

b. AREAS REQUIRING CORRECTIVE ACTION: 5.a.3.

ISSUE NO.: 64-11-5a3-A-05 56 6

Unclassified Radiological Emergency Preparedness Program (REP)

After Action Report/Improvement Plan Three Mile Island Nuclear Generating Station CRITERION: Activities associated with FEMA approved exception areas are completed within 45 minutes following the initial decision by authorized offsite emergency officials to notify the public of an emergency situation. Backup A&N of the public is completed within 45 minutes following the detection by the ORO of a failure of the primary A&N system. (NUREG-0654, E.6., Appendix 3.B.2.c)

CONDITION: The criterion requires Backup Route Alerting to be. completed in 45 minutes; however, the evaluated Route Alert Team completed the route in 49 minutes.

POSSIBLE CAUSE: The Radiological Briefing, issuance of dosimetry and KI, and completion of the "Dosimetry/KI Form", for all emergency workers caused a delay of 10 - 12 minutes in dispatching the Route Alert Team. The evaluated route alert team, which also drove the longest alert route, was not processed first.

REFERENCE:

NUREG 0654, E.6, J.10.c. S. Londonderry Twp RERP, Appendix 33.B.2.c EFFECT: Residents in the coverage area of the failed siren were not notified in a timely manner.

CORRECTIVE ACTION DEMONSTRATED: During a re-demonstration drill on May 9, 2001 the South Londonderry Township Backup Route Alert successfully redemonstrated this criterion.

During a re-demonstration exercise the South Londonderry Township Emergency Operations Center was notified via controller inject of an Alert at Three Mile Island Nuclear Generating Station. The S. Londonderry Township Emergency Management Coordinator (EMC) notified the Route Alerting Teams at Lawn Fire Department to prepare for possible Route Alerting. The Radiological Officer at Lawn Fire Department organized the Route Alerting Teams and conducted a thorough radiological briefing to include issuance of dosimetry and Potassium Iodide (KI) utilizing the appropriate Dosimetry/KI issue form. The exercise escalated to a Site Area Emergency (SAE) at 1928 hours0.0223 days <br />0.536 hours <br />0.00319 weeks <br />7.33604e-4 months <br /> along with a notification of sounding of the 57

Unclassified Radiological Emergency Preparedness Program (REP)

After Action Report/Improvement Plan Three Mile Island Nuclear Generating Station sirens at 1943 hours0.0225 days <br />0.54 hours <br />0.00321 weeks <br />7.393115e-4 months <br />. Upon identification of a failed siren #201, the Lawn Fire Department Route Alerting Team identified and began the appropriate route, and completed Back-up Route Alerting in 25 minutes. The Route Alerting Team made appropriate announcements throughout their route and reported one dosimeter reading via radio to the Radiological Officer.

All activities were based on the plans and procedures and completed as they would have been in an actual emergency except as noted in the extent of play agreement.

c.

DEFICIENCY: None

d. PLAN ISSUES: None
e.

NOT DEMONSTRATED: None

f. PRIOR ISSUES - RESOLVED: None
g. PRIOR ISSUES - UNRESOLVED: None 3.3.2.43 Lebanon County, South Londonderry Township Traffic and Access Control
a.

MET: 1.d. 1, 1.e. 1, 3.a. 1, 3.b. 1, 3.d. 1, 3.d.2.

b. AREAS REQUIRING CORRECTIVE ACTION: None
c.

DEFICIENCY: None

d. PLAN ISSUES: None
e.

NOT DEMONSTRATED: None

f. PRIOR ISSUES - RESOLVED: None
g. PRIOR ISSUES - UNRESOLVED: None 3.3.2.44 York County Emergency Operation Center
a.

M ET: 1.a. 1, l.c. 1, 1.d. 1, 1.e. 1, 2.a. 1, 2.c. 1, 3.a. 1, 3.b. 1, 3.c. 1, 3.c.2, 3.d. 1, 3.d.2, 5.a. 1, 5.a.3, 5.b.1.

b. AREAS REQUIRING CORRECTIVE ACTION: None
c.

DEFICIENCY: None

d. PLAN ISSUES: None
e.

NOT DEMONSTRATED: None

f.

PRIOR ISSUES - RESOLVED: None

g. PRIOR ISSUES - UNRESOLVED: None 58 4

Unclassified Radiological Emergency Preparedness Program (REP)

After Action Report/Improvement Plan Three Mile Island Nuclear.Generating Station 3.3.2.45 York County Emergency Worker Monitoring and Decontamination Station, Monaghan Fire Department

a.

MET: 1.e.1,3.a.1,6.a.1,6.b.1.

b.

AREAS REQUIRING CORRECTIVE ACTION: None

c.

DEFICIENCY: None

d. PLAN ISSUES: None
e.

NOT DEMONSTRATED: None

f.

PRIOR ISSUES - RESOLVED: None

g. PRIOR ISSUES - UNRESOLVED: None 3.3.2.46 York County Reception Center, Southern School Complex
a.

MET: 1.d.1, 1.e. 1, 3.d.1.

b.

AREAS REQUIRING CORRECTIVE ACTION: None

c.

DEFICIENCY: None

d. PLAN ISSUES: None
e.

NOT DEMONSTRATED: None

f.

PRIOR ISSUES - RESOLVED: None

g. PRIOR ISSUES - UNRESOLVED: None 3.3.2.47 York County Monitoring and Decontamination Center, Southern School Complex High School
a.

MET: 1.e.1,3.a.1,3.b.1,6.a.1.

b.

AREAS REQUIRING CORRECTIVE ACTION: None

c.

DEFICIENCY: None

d. PLAN ISSUES: None
e.

NOT DEMONSTRATED: None

f.

PRIOR ISSUES - RESOLVED: None

g. PRIOR ISSUES - UNRESOLVED: None 3.3.2.48 York County Mass Care Center, Southern School Complex
a.

MET: 1.e.1,6.a.1,6.c.1.

b. AREAS REQUIRING CORRECTIVE ACTION: None
c.

DEFICIENCY: None

d. PLAN ISSUES: None
e.

NOT DEMONSTRATED: None 59

Unclassified Radiological Emergency Preparedness Program (REP)

After Action Report/Improvement Plan Three Mile Island Nuclear Generating Station

f.

PRIOR ISSUES - RESOLVED: None

g.

PRIOR ISSUES - UNRESOLVED: None 3.3.2.49 York County, Dover Township Emergency Operations Center

a.

M ET: 1.a.1, 1.c.l, i.d.1, 1.e.1, 2.c.1,.3.a.1, 3.b.1, 3.c.1, 3.d.1, 3.d.2, 5.a.1.

b.

AREAS REQUIRING CORRECTIVE ACTION: None

c.

DEFICIENCY: None

d.

PLAN ISSUES: None

e.

NOT DEMONSTRATED: None

f.

PRIOR ISSUES - RESOLVED: None

g. PRIOR ISSUES - UNRESOLVED: None 3.3.2.50 York County, Lewisbury Borough/Newberry Township Emergency Operations Center
a.

MET: 1.a.1, 1.c.1, 1.d.1, I.e.1, 2.c.1, 3.a.1, 3.b.1, 3.d.1, 3.d.2, 5.a.1, 5.a.3.

b. AREAS REQUIRING CORRECTIVE ACTION: 3.a.1, 5.a.3.

ISSUE NO.: 64-11-3al-A-06 CRITERION: OROs issue appropriate dosimetry and procedures, and manage radiological exposure to emergency workers JAW plans and procedures. Emergency workers periodically and at the end of each mission read and record dosimeter reading. (NUREG-0654, K.3)

CONDITION: The radiation briefing provided for the back-up route alerting team was not understood and included extraneous information.

POSSIBLE CAUSE: A team assigned for the back-up route alerting mission provided with a radiation briefing contained on a DVD that included information that was not appropriate to the Newberry site, such as: use of electronic dosimeters and trigger dosimeter chargers. Interviews with team members showed that they did not understand the 5 rem limit for emergency workers.

REFERENCE:

NUREG-0654, K.3 EFFECT: Emergency workers performing the route alerting could have received an 60 I

Unclassified Radiological Emergency Preparedness Program (REP)

After Action Report/Improvement Plan Three Mile Island Nuclear Generating Station excessive radiation dose.

CORRECTIVE ACTION DEMONSTRATED: The team returned to the EOC, was provided with a revised radiation briefing and interviews with team members showed an adequate understanding of the dose limit for radiation workers.

ISSUE NO.: 64-11-5a3-A-07 CRITERION: Activities associated with FEMA approved exception areas are completed within 45 minutes following the initial decision by authorized offsite emergency officials to notify the public of an emergency situation. Backup A&N of the public is completed within 45 'minutes following the detection by the ORO of a failure of the primary A&N system. (NUREG-0654, E.6., Appendix 3.B.2.c)

CONDITION: Backup Route Alerting for siren #533 was not completed within the required 45 minutes.

POSSIBLE CAUSE: A team assigned for the mission was called to an actual emergency. The back-up team was late arriving at the EOC and the radiation briefing was too long - leaving too little time to perform the mission in the allotted time.

REFERENCE:

NUREG-0654, E.6, Appendix 3.B.2.c EFFECT: Personnel living in the area of siren #533 would not have been notified of a nuclear emergency in a timely manner.

CORRECTIVE ACTION DEMONSTRATED: The team returned to the EOC, was provided with a revised radiation briefing and re-covered the route in approximately 30 minutes.

c.

DEFICIENCY: None

d. PLAN ISSUES: None 61

Unclassified Radiological Emergency Preparedness Program (REP)

After Action Report/Improvement Plan Three Mile Island Nuclear Generating Station

e.

NOT DEMONSTRATED: None

f. PRIOR ISSUES - RESOLVED: None
g.

PRIOR ISSUES - UNRESOLVED: None 3.3.2.51 York County, Newberry Township Back-up Route Alerting

a.

MET: 1.d.1, 1.e.1, 3.a.1, 3.b.1, 5.a.3.

b. AREAS REQUIRING CORRECTIVE ACTION: None
c.

DEFICIENCY: None

d. PLAN ISSUES: None
e.

NOT DEMONSTRATED: None 6

f. PRIOR ISSUES - RESOLVED: None
g. PRIOR ISSUES - UNRESOLVED: None 3.3.2.52 York County, Manchester Township Emergency Operations Center
a.

M ET: 1.a.1, 1.c.1, 1.d.1, 1.e.1, 2.c.1, 3.a.1, 3.b.1, 3.c.1, 3.d.1, 3.d.2, 5.a.1.

b.

AREAS REQUIRING CORRECTIVE ACTION: None

c.

DEFICIENCY: None

d. PLAN ISSUES: None
e.

NOT DEMONSTRATED: None

f.

PRIOR ISSUES - RESOLVED: None

g.

PRIOR ISSUES - UNRESOLVED: None 3.3.2.53 York County, Northeast Area Emergency Operations Center (Mount Wolf, Manchester Borough, E Manchester Township)

a.

M ET: 1.a. 1, 1.c. 1, 1.d. 1, 1.e. 1, 2.c. 1, 3.a. 1, 3.b. 1, 3.c. 1, 3.d. 1, 3.d.2, 5.a. 1.

b. AREAS REQUIRING CORRECTIVE ACTION: None
c.

DEFICIENCY: None

d. PLAN ISSUES: None
e.

NOT DEMONSTRATED: None

f.

PRIOR ISSUES - RESOLVED: None

g. PRIOR ISSUES - UNRESOLVED: None 62 4

Unclassified Radiological Emergency Preparedness Program (REP)

After Action Report/Improvement Plan Three Mile Island Nuclear Generating Station 3.3.2.54 Franklin County Mass Care Center, Faust Junior High School

a.

MET: 1.e.1, 6.a.1, 6.c.1.

b.

AREAS REQUIRING CORRECTIVE ACTION: None

c.

DEFICIENCY: None

d. PLAN ISSUES: None
e.

NOT DEMONSTRATED: None

f.

PRIOR ISSUES - RESOLVED: None

g.

PRIOR ISSUES - UNRESOLVED: None 3.3.2.55 Dauphin County, Capital Area Intermediate Unit, Administration Building

a.

MET: 3.c.2.

b.

AREAS REQUIRING CORRECTIVE ACTION: None

c.

DEFICIENCY: None

d.

PLAN ISSUES: None

e.

NOT DEMONSTRATED: None:

f.

PRIOR ISSUES - RESOLVED: None

g.

PRIOR ISSUES - UNRESOLVED: None 3.3.2.56 Dauphin County, Capital Area Intermediate Unit, Capital Area School for the Arts

a.

MET: 3.c.2.

b.

AREAS REQUIRING CORRECTIVE ACTION: None

c.

DEFICIENCY: None

d.

PLAN ISSUES: None

e.

NOT DEMONSTRATED: None

f.

PRIOR ISSUES - RESOLVED: None

g.

PRIOR ISSUES - UNRESOLVED: None 3.3.2.57 Dauphin County, Central Dauphin School District

a.

MET: 3.c.2.

b. AREAS REQUIRING CORRECTIVE ACTION: None
c.

DEFICIENCY: None

d.

PLAN ISSUES: None

e.

NOT DEMONSTRATED: None

f.

PRIOR ISSUES - RESOLVED: None

g.

PRIOR ISSUES - UNRESOLVED: None 63

Unclassified Radiological Emergency Preparedness Program (REP)

After Action Report/Improvement Plan Three Mile Island Nuclear Generating Station 3.3.2.58 Dauphin County, Central Dauphin School District, Central Dauphin East High School

a.

MET: 3.c.2.

b.

AREAS REQUIRING CORRECTIVE ACTION: None

c.

DEFICIENCY: None

d.

PLAN ISSUES: None

e.

NOT DEMONSTRATED: None

f.

PRIOR ISSUES - RESOLVED: None

g. PRIOR ISSUES - UNRESOLVED: None 3.3.2.59 Dauphin County, Central Dauphin School District, Swatara Middle School
a.

MET: 3.c.2.

b.

AREAS REQUIRING CORRECTIVE ACTION: None

c.

DEFICIENCY: None

d.

PLAN ISSUES: None

e.

NOT DEMONSTRATED: None

f.

PRIOR ISSUES - RESOLVED: None

g.

PRIOR ISSUES - UNRESOLVED: None 3.3.2.60 Dauphin County, Central Dauphin School District, Tri Community Elementary School

a.

MET: 3.c.2.

b.

AREAS REQUIRING CORRECTIVE ACTION: None

c.

DEFICIENCY: None

d.

PLAN ISSUES: None

e.

NOT DEMONSTRATED: None

f.

PRIOR ISSUES - RESOLVED: None

g.

PRIOR ISSUES - UNRESOLVED: None 3.3.2.61 Dauphin County, Derry Township School District

a.

MET: 3.c.2.

b.

AREAS REQUIRING CORRECTIVE ACTION: None

c.

DEFICIENCY: None

d.

PLAN ISSUES: None

e.

NOT DEMONSTRATED: None 64 4

Unclassified Radiological Emergency Preparedness Program (REP)

After Action Report/Improvement Plan Three Mile Island Nuclear Generating Station

f.

PRIOR ISSUES - RESOLVED: None

g.

PRIOR ISSUES - UNRESOLVED: None 3.3.2.62 Dauphin County, Derry Township School District, Hershey Intermediate Elementary School

a.

MET: 3.c.2.

b.

AREAS REQUIRING CORRECTIVE ACTION: None

c.

DEFICIENCY: None

d. PLAN ISSUES: None
e.

NOT DEMONSTRATED: None

f.

PRIOR ISSUES - RESOLVED: None

g. PRIOR ISSUES - UNRESOLVED: None 3.3.2.63 Dauphin County, Derry Township School District, Hershey Middle School
a.

MET: 3.c.2.

b. AREAS REQUIRING CORRECTIVE ACTION: None
c.

DEFICIENCY: None

d. PLAN ISSUES: None
e.

NOT DEMONSTRATED: None

f.

PRIOR ISSUES - RESOLVED: None

g. PRIOR ISSUES - UNRESOLVED: None 3.3.2.64 Dauphin County, Harrisburg School District
a.

MET: 3.c.2.

b. AREAS REQUIRING CORRECTIVE ACTION: None
c.

DEFICIENCY: None

d. PLAN ISSUES: None
e.

NOT DEMONSTRATED: None

f.

PRIOR ISSUES - RESOLVED: None

g.

PRIOR ISSUES - UNRESOLVED: None 65

Unclassified Radiological Emergency Preparedness Program (REP)

After Action Report/Improvement Plan Three Mile Island Nuclear Generating Station 3.3.2.65 Dauphin County, Harrisburg School District, Harrisburg High School

a.

MET: 3.c.2.

b.

AREAS REQUIRING CORRECTIVE ACTION: None

c.

DEFICIENCY: None

d.

PLAN ISSUES: None

e.

NOT DEMONSTRATED: None

f.

PRIOR ISSUES - RESOLVED: None

g. PRIOR ISSUES - UNRESOLVED: None 3.3.2.66 Dauphin County, Harrisburg School District, Scott School
a.

MET: 3.c.2.

b. AREAS REQUIRING CORRECTIVE ACTION: None
c.

DEFICIENCY: None

d. PLAN ISSUES: None
e.

NOT DEMONSTRATED: None

f.

PRIOR ISSUES - RESOLVED: None

g. PRIOR ISSUES - UNRESOLVED: None 3.3.2.67 Dauphin County, Harrisburg School District, Shimmell School
a.

MET: 3.c.2.

b.

AREAS REQUIRING CORRECTIVE ACTION: None

c.

DEFICIENCY: None

d. PLAN ISSUES: 3.c.2.

ISSUE NO.: 64-11-3c2-P-02 CRITERION: OROs/school officials decide upon and implement protective actions for schools (NUREG-0654, J.10.c.d.g.)

CONDITION: The Harrisburg City School District Radiological Protection Plan does not reflect the procedures in the Shimmel School Plan.

The Shimmel School is outside the 10-mile emergency planning zone (EPZ), and has about 35 students living inside the EPZ. The school has two student populations with special requirements. Due to the sensitive nature of the two groups the principal developed four emergency classification responses. The school plan identifies an 66

Unclassified Radiological Emergency Preparedness Program (REP)

After Action Report/Improvement Plan Three Mile Island Nuclear Generating Station incident at the Three Mile Island Nuclear Generating Station as a Code Red. A Code Red calls for evacuating the entire student population to the Rowlen Middle School gym, located about 2-3 blocks from the Shimmel School. The parents would be notified to pick up their students from there. The School District plan states that only the students living in the EPZ will be dismissed and picked up by their parents and the rest of the students will be dismissed as usual.

POSSIBLE CAUSE: The Harrisburg City School District Plan has not been updated to reflect the procedures in the Shimmel School Plan.

REFERENCE:

NUREG-0654, J. 1O.c, d, g; Harrisburg City School District ALL HAZARDS School Safety Plan, Section 7 - Radiological Emergency Response Plan, Appendix 7-5.6.

EFFECT: Personnel at the Harrisburg City School District offices would not be able to give parents the correct information on where to pick up their children that attend the Shimmel School.,

CORRECTIVE ACTION DEMONSTRATED: The Pennslyvania Emergency Management Agency has provided an official letter of notification to FEMA of the Shimmell School's closure, therefore the planning issue assessed at this location is administratively closed.

e.

NOT DEMONSTRATED: None

f.

PRIOR ISSUES - RESOLVED: None

g. PRIOR ISSUES - UNRESOLVED: None 3.3.2.68 Dauphin County, Lower Dauphin School District
a.

MET: 3.c.2.

b. AREAS REQUIRING CORRECTIVE ACTION: None
c.

DEFICIENCY: None

d. PLAN ISSUES: None
e.

NOT DEMONSTRATED: None

f. PRIOR ISSUES - RESOLVED: None
g. PRIOR ISSUES - UNRESOLVED: None 67

Unclassified Radiological Emergency Preparedness Program (REP)

After Action Report/Improvement Plan Three Mile Island Nuclear Generating Station 3.3.2.69 Dauphin County, Lower Dauphin School District, Lower Dauphin High School

a.

MET: 3.c.2.

b. AREAS REQUIRING CORRECTIVE ACTION: None
c.

DEFICIENCY: None

d. PLAN ISSUES: None
e.

NOT DEMONSTRATED: None

f.

PRIOR ISSUES - RESOLVED: None

g.

PRIOR ISSUES - UNRESOLVED: None 3.3.2.70 Dauphin County, Lower Dauphin School District, Price Building

a.

MET: 3.c.2.

b. AREAS REQUIRING CORRECTIVE ACTION: None
c.

DEFICIENCY: None

d. PLAN ISSUES: None
e.

NOT DEMONSTRATED: None

f.

PRIOR ISSUES - RESOLVED: None

g.

PRIOR ISSUES - UNRESOLVED: None 3.3.2.71 Dauphin County, Lower Dauphin School Distirct, South Hanover Elementary School

a.

MET: 3.c.2.

b. AREAS REQUIRING CORRECTIVE ACTION: None
c.

DEFICIENCY: None

d. PLAN ISSUES: None
e.

NOT DEMONSTRATED: None

f.

PRIOR ISSUES - RESOLVED: None

g. PRIOR ISSUES - UNRESOLVED: None 3.3.2.72 Dauphin County, Middletown Area School District
a.

MET: 3.c.2.

b.

AREAS REQUIRING CORRECTIVE ACTION: None

c.

DEFICIENCY: None

d.

PLAN ISSUES: None

e.

NOT DEMONSTRATED: None

f.

PRIOR ISSUES - RESOLVED: None 68 0

Unclassified Radiological Emergency Preparedness Program (REP)

After Action Report/Improvement Plan Three Mile Island Nuclear Generating Station

g.

PRIOR ISSUES - UNRESOLVED: None 3.3.2.73 Dauphin County, Middletown Area School District, Middletown High School

a.

MET: 3.c.2.

b.

AREAS REQUIRING CORRECTIVE ACTION: None

c.

DEFICIENCY: None

d. PLAN ISSUES: None
e. NOT DEMONSTRATED: None
f.

PRIOR ISSUES - RESOLVED: None

g. PRIOR ISSUES - UNRESOLVED: None 3.3.2.74 Dauphin County, Milton Hershey. School
a.

MET: 3.c.2.

b.

AREAS REQUIRING CORRECTIVE ACTION: None

c.

DEFICIENCY: None

d. PLAN ISSUES: None
e.

NOT DEMONSTRATED: None

f.

PRIOR ISSUES - RESOLVED: None

g. PRIOR ISSUES - UNRESOLVED: None 3.3.2.75 Dauphin County, Steelton-Highspire School District
a.

MET: 3.c.2.

b.

AREAS REQUIRING CORRECTIVE ACTION: None

c.

DEFICIENCY: None

d. PLAN ISSUES: None
e.

NOT DEMONSTRATED: None

f.

PRIOR ISSUES - RESOLVED: None

g. PRIOR ISSUES - UNRESOLVED: None 3.3.2.76 Dauphin County, Steelton-Highspire School District, Steelton-Highspire High School
a.

MET: 3.c.2.

b. AREAS REQUIRING CORRECTIVE ACTION: None
c.

DEFICIENCY: None

d. PLAN ISSUES: None 69

Unclassified Radiological Emergency Preparedness Program (REP)

After Action Report/Improvement Plan Three Mile Island Nuclear Generating Station

e.

NOT DEMONSTRATED: None

f.

PRIOR ISSUES - RESOLVED: None

g. PRIOR ISSUES - UNRESOLVED: None 3.3.2.77 Lancaster County, Donegal School District
a.

MET: 3.c.2.

b. AREAS REQUIRING CORRECTIVE ACTION: None
c.

DEFICIENCY: None

d. PLAN ISSUES: None
e.

NOT DEMONSTRATED: None

f.

PRIOR ISSUES - RESOLVED: None

g. PRIOR ISSUES - UNRESOLVED: None 3.3.2.78 Lancaster County, Donegal School District, Donegal High School
a.

MET: 3.c.2.

b. AREAS REQUIRING CORRECTIVE ACTION: None
c.

DEFICIENCY: None

d. PLAN ISSUES: None
e.

NOT DEMONSTRATED: None

f. PRIOR ISSUES - RESOLVED: None
g. PRIOR ISSUES - UNRESOLVED: None 3.3.2.79 Lancaster County, Donegal School District, Donegal Springs Elementary School
a.

MET: 3.c.2.

b. AREAS REQUIRING CORRECTIVE ACTION: None
c.

DEFICIENCY: None

d. PLAN ISSUES: None
e.

NOT DEMONSTRATED: None

f.

PRIOR ISSUES - RESOLVED: None

g. PRIOR ISSUES - UNRESOLVED: None 70 0

Unclassified Radiological Emergency Preparedness Program (REP)

After Action Report/Improvcment Plan Three Mile Island Nuclear Generating Station 3.3.2.80 Lancaster County, Elizabethtown Area School District

a.

MET: 3.c.2.

b. AREAS REQUIRING CORRECTIVE ACTION: None
c.

DEFICIENCY: None

d. PLAN ISSUES: None
e.

NOT DEMONSTRATED: None

f.

PRIOR ISSUES - RESOLVED: None

g.

PRIOR ISSUES - UNRESOLVED: None 3.3.2.81 Lancaster County, Elizabethtow Area School District, East High Street Elemementary School

a.

MET: 3.c.2.

b. AREAS REQUIRING CORRECTIVE ACTION: None
c.

DEFICIENCY: None

d. PLAN ISSUES: None
e.

NOT DEMONSTRATED: None

f.

PRIOR ISSUES - RESOLVED: None

g.

PRIOR ISSUES - UNRESOLVED: None 3.3.2.82 Lancaster County, Elizabethtown Area School District, Fairview Elementary School

a.

MET: 3.c.2.

b. AREAS REQUIRING CORRECTIVE ACTION: None
c.

DEFICIENCY: None

d. PLAN ISSUES: None
e.

NOT DEMONSTRATED: None

f.

PRIOR ISSUES - RESOLVED: None

g.

PRIOR ISSUES - UNRESOLVED: None 3.3.2.83 Lancaster County, Elezabethtown Aera School District, Mill Road Elementary School

a.

MET: 3.c.2.

b. AREAS REQUIRING CORRECTIVE ACTION: None
c.

DEFICIENCY: None

d. PLAN ISSUES: None 71

Unclassified Radiological Emergency Preparedness Program (REP)

After Action Report/Improvement Plan Three Mile Island Nuclear Generating Station

e.

NOT DEMONSTRATED: None

f.

PRIOR ISSUES - RESOLVED: None

g. PRIOR ISSUES - UNRESOLVED: None 3.3.2.84 Lebanon County, Palmyra Area School District
a.

MET: 3.c.2.

b. AREAS REQUIRING CORRECTIVE ACTION: None
c.

DEFICIENCY: None

d. PLAN ISSUES: None
e.

NOT DEMONSTRATED: None

f.

PRIOR ISSUES - RESOLVED: None

g. PRIOR ISSUES - UNRESOLVED: None 3.3.2.85 Lebanon County, Palmyra Area School District, Palmyra High School
a.

MET: 3.c.2.

b. AREAS REQUIRING CORRECTIVE ACTION: None
c.

DEFICIENCY: None

d. PLAN ISSUES: None
e.

NOT DEMONSTRATED: None

f.

PRIOR ISSUES - RESOLVED: None

g. PRIOR ISSUES - UNRESOLVED: None 3.3.2.86 York County, Central York School District
a.

MET: 3.c.2.

b. AREAS REQUIRING CORRECTIVE ACTION: None
c.

DEFICIENCY: None

d. PLAN ISSUES: None
e.

NOT DEMONSTRATED: None

f.

PRIOR ISSUES - RESOLVED: None

g. PRIOR ISSUES - UNRESOLVED: None 72

Unclassified Radiological Emergency Preparedness Program (REP)

After Action Report/Improvement Plan Three Mile Island Nuclear Generating Station 3.3.2.87 York County, Central York School District, Central York Middle School

a.

MET: 3.c.2.

b. AREAS REQUIRING CORRECTIVE ACTION: None
c.

DEFICIENCY: None

d. PLAN ISSUES: None
e.

NOT DEMONSTRATED: None f,

PRIOR ISSUES - RESOLVED: None

g. PRIOR ISSUES - UNRESOLVED: None 3.3.2.88 York County, Central York School District, Hayshire Elementary School
a.

MET: 3.c.2.

b. AREAS REQUIRING CORRECTIVE ACTION: None
c.

DEFICIENCY: None

d. PLAN ISSUES: None
e.

NOT DEMONSTRATED: None

f.

PRIOR ISSUES - RESOLVED: None

g. PRIOR ISSUES - UNRESOLVED: None 3.3.2.89 York County, Central York School District, Roundtown Elementary School
a.

MET: 3.c.2.

b. AREAS REQUIRING CORRECTIVE ACTION: None
c.

DEFICIENCY: None

d. PLAN ISSUES: None
e.

NOT DEMONSTRATED: None

f.

PRIOR ISSUES - RESOLVED: None

g. PRIOR ISSUES - UNRESOLVED: None 3.3.2.90 York County, Dover Area School Distriict
a.

MET: 3.c.2.

b. AREAS REQUIRING CORRECTIVE ACTION: 3.c.2.

ISSUE NO.: 64-11-3c2-A-08 CRITERION: OROs/school officials decide upon and implement protective actions for schools (NUREG-0654, J.10.c.d.g.)

73

Unclassified Radiological Emergency Preparedness Program (REP)

After Action Report/Improvement Plan Three Mile Island Nuclear Generating Station CONDITION: The Dover Area School District Assistant Superintendent, acting on behalf of the Superintendent, did not order the dismissal of all non-EPZ students and the transfer of EPZ students to North Salem Elementary School when an evacuation was ordered by the Governor, as required by the Dover Area School District Three Mile Island Evacuation Plan (03/07/11),Section VI.D, Concept of Operations, General Emergency.

POSSIBLE CAUSE: The Dover Area School District Three Mile Island Evacuation Plan (03/07/11),Section VI, Concept of Operations, states that the Superintendent will order the dismissal of all non-EPZ students and the transfer of EPZ students to North Salem Elementary School, but checklists in the plan do not include steps to initiate an early dismissal.

REFERENCE:

Dover Area School District Three Mile Island Evacuation Plan (03/07/11),Section VI.D (03/07/11); NUREG-0654, J. 10.g, page 9.

EFFECT: There may have been some confusion at the individual schools as to if an early dismissal and transfer of students was going to happen.

CORRECTIVE ACTION DEMONSTRATED: On April 29, 2011, Dover Area School District demonstrated the necessary actions to fulfill this criterion during a re-demonstration of the Three Mile Island Nuclear Generating Station out-of-sequence schools exercise.

During this re-demonstration, the Dover School District Safety Officer, acting on behalf of the Dover School District Superintendent demonstrated the early dismissal of all non-EPZ students and transfer of EPZ students to North Salem Elementary School when an evacuation was ordered by the Governor. This re-demonstration was conducted via phone calls generated from the York County Department of Emergency Services to the Dover Area School District Administrative Office. The exercise began at Site Area Emergency at approximately 0915 hours0.0106 days <br />0.254 hours <br />0.00151 weeks <br />3.481575e-4 months <br />, followed by General Emergency at 0934 and an ordered evacuation at 0945 hours0.0109 days <br />0.263 hours <br />0.00156 weeks <br />3.595725e-4 months <br />. An updated call down list was utilized to notify the Dover School District schools of the early dismissal decision including the High School, Intermediate School, and notification 74

Unclassified Radiological Emergency Preparedness Program (REP)

After Action Report/Improvement Plan Three Mile Island Nuclear Generating Station to North Salem Elementary School of the transfer of EPZ students. An updated evacuation plan dated 4/13/2011 was also provided with highlighted changes. The exercise demonstration was completed at 1120 hours0.013 days <br />0.311 hours <br />0.00185 weeks <br />4.2616e-4 months <br />.

All activities were based on the plans and procedures and completed as they would have been in an actual emergency except as noted in the extent of play agreement.

c.

DEFICIENCY: None

d.

PLAN ISSUES: None

e.

NOT DEMONSTRATED: None

f.

PRIOR ISSUES - RESOLVED: None

g.

PRIOR ISSUES - UNRESOLVED: None 3.3.2.91 York County, Dover Area School District, Dover Intermediate School

a.

MET: 3.c.2,.

b. AREAS REQUIRING CORRECTIVE ACTION: None
c.

DEFICIENCY: None

d.

PLAN ISSUES: None

e.

NOT DEMONSTRATED: None

f.

PRIOR ISSUES - RESOLVED: None

g. PRIOR ISSUES - UNRESOLVED: None 3.3.2.92 York County, Eastern York School District
a.

MET: 3.c.2.

b. AREAS REQUIRING CORRECTIVE ACTION: None
c.

DEFICIENCY: None

d. PLAN ISSUES: None
e.

NOT DEMONSTRATED: None

f.

PRIOR ISSUES - RESOLVED: None

g.

PRIOR ISSUES - UNRESOLVED: None 75

Unclassified Radiological Emergeincy Preparedness Program (REP)

After Action Report/Improvement Plan Three Mile Island Nuclear Generating Station 3.3.2.93 York County, Eastern York School District, Kreutz Creek Elementary School

a.

MET: 3.c.2.

b.

AREAS REQUIRING CORRECTIVE ACTION: None

c.

DEFICIENCY: None

d. PLAN ISSUES: None
e.

NOT DEMONSTRATED: None

f.

PRIOR ISSUES - RESOLVED: None

g. PRIOR ISSUES - UNRESOLVED: None 3.3.2.94 York County, Northeastern School District
a.

MET: 3.c.2.

b. AREAS REQUIRING CORRECTIVE ACTION: None
c.

DEFICIENCY: None

d. PLAN ISSUES: None
e.

NOT DEMONSTRATED: None

f.

PRIOR ISSUES - RESOLVED: None

g. PRIOR ISSUES - UNRESOLVED: None 3.3.2.95 York County, Northeastern School District, Northeastern Middle School
a.

MET: 3.c.2.

b.

AREAS REQUIRING CORRECTIVE ACTION: None

c.

DEFICIENCY: None

d. PLAN ISSUES: None
e. NOT DEMONSTRATED: None
f.

PRIOR ISSUES - RESOLVED: None

g. PRIOR ISSUES - UNRESOLVED: None 3.3.2.96 York County, Northeastern School District, Shallow Brook Intermediate School,
a.

MET: 3.c.2.

b.

AREAS REQUIRING CORRECTIVE ACTION: None

c.

DEFICIENCY: None

d. PLAN ISSUES: None
e. NOT DEMONSTRATED: None
f.

PRIOR ISSUES - RESOLVED: None

g. PRIOR ISSUES - UNRESOLVED: None 76 0

Unclassified Radiological Emergency Preparedness Program (REP)

After Action Report/Improvement Plan Three Mile Island Nuclear Generating Station 3.3.2.97 York County, Northeastern School District, Spring Forge Intermediate School

a.

MET: 3.c.2.

b.

AREAS REQUIRING CORRECTIVE ACTION: None

c.

DEFICIENCY: None

d. PLAN ISSUES: None
e. NOT DEMONSTRATED: None
f.

PRIOR ISSUES - RESOLVED: None

g. PRIOR ISSUES - UNRESOLVED: None 3.3.2.98 York County, Northeastern School District, York Haven Elementary School
a.

MET: 3.c.2.

b.

AREAS REQUIRING CORRECTIVE ACTION: None

c.

DEFICIENCY: None

d. PLAN ISSUES: None
e.

NOT DEMONSTRATED: None

f.

PRIOR ISSUES - RESOLVED: None

g.

PRIOR ISSUES - UNRESOLVED: None 3.3.2.99 York County, West Shore School District,

a.

MET: 3.c.2.

b.

AREAS REQUIRING CORRECTIVE ACTION: None

c.

DEFICIENCY: None

d. PLAN ISSUES: None
e. NOT DEMONSTRATED: None
f.

PRIOR ISSUES - RESOLVED: None

g. PRIOR ISSUES - UNRESOLVED: None 3.3.2.100 York County, West Shore School District, Allen Middle School
a.

MET: 3.c.2.

b. AREAS REQUIRING CORRECTIVE ACTION: None
c.

DEFICIENCY: None

d. PLAN ISSUES: None
e.

NOT DEMONSTRATED: None

f.

PRIOR ISSUES - RESOLVED: None

g. PRIOR ISSUES - UNRESOLVED: None 77

Unclassified Radiological Emergency Preparedness Program (REP)

After Action Report/Improvement Plan Three Mile Island Nuclear Generating Station 3.3.2.101 York County, West Shore School District, Cedar Cliff High School

a.

MET: 3.c.2.

b.

AREAS REQUIRING CORRECTIVE ACTION: None

c.

DEFICIENCY: None

d.

PLAN ISSUES: None

e.

NOT DEMONSTRATED: None

f.

PRIOR ISSUES - RESOLVED: None

g.

PRIOR ISSUES - UNRESOLVED: None 3.3.2.102 York County, West Shore School District, Highland Elementary School

a.

MET: 3.c.2.

b. AREAS REQUIRING CORRECTIVE ACTION: None
c.

DEFICIENCY: None

d. PLAN ISSUES: None
e.

NOT DEMONSTRATED: None

f.

PRIOR ISSUES - RESOLVED: None

g. PRIOR ISSUES - UNRESOLVED: None 3.3.2.103 York County, West Shore School District, New Cumberland Middle School
a.

MET: 3.c.2.

b. AREAS REQUIRING CORRECTIVE ACTION: None
c.

DEFICIENCY: None

d. PLAN ISSUES: None
e.

NOT DEMONSTRATED: None

f.

PRIOR ISSUES - RESOLVED: None

g. PRIOR ISSUES - UNRESOLVED: None 3.3.2.104 York County, West Shore School District, Red Mill Elementary School
a.

MET: 3.c.2.

b. AREAS REQUIRING CORRECTIVE ACTION: None
c.

DEFICIENCY: None

d. PLAN ISSUES: None
e.

NOT DEMONSTRATED: None

f.

PRIOR ISSUES - RESOLVED: None

g. PRIOR ISSUES - UNRESOLVED: None 78 0

Unclassified Radiological Emergency Preparedness Program (REP)

After Action Report/Improvement Plan Three Mile Island Nuclear Generating Station 3.3.2.105 Lebanon County, Eastern Lebanon High School Complex

a.

MET: 6.a.1, 6.c.1.

b.

AREAS REQUIRING CORRECTIVE ACTION: None

c.

DEFICIENCY: None

d.

PLAN ISSUES: None

e. NOT DEMONSTRATED: None
f.

PRIOR ISSUES - RESOLVED: None

g. PRIOR ISSUES - UNRESOLVED: None 3.3.3 Support Jurisdictions 3.3.3.1 Cumberland County Mass Care Center, Big Spring High School
a.

MET: 1.e.1, 6.a.1, 6.c.1.

b.

AREAS REQUIRING CORRECTIVE ACTION: None

c.

DEFICIENCY: None

d. PLAN ISSUES: None
e.

NOT DEMONSTRATED: None

f.

PRIOR ISSUES - RESOLVED: None g.1 PRIOR ISSUES -,UNRESOLVED: None 3.3.3.2 Lancaster County Mass Care Center, Manheim Township High School

a.

MET: 1.b.1, 6.a.1.

b. AREAS REQUIRING CORRECTIVE ACTION: None
c.

DEFICIENCY: None

d. PLAN ISSUES: None
e.

NOT DEMONSTRATED: 6.c. 1.

f.

PRIOR ISSUES - RESOLVED: None

g. PRIOR ISSUES - UNRESOLVED: None 3.3.3.3 Adams County Emergency Operations Center
a.

MET: 1.a.1, 1.c.1, 1.d.1, 1.e.1, 5.b.1.

b. AREAS REQUIRING CORRECTIVE ACTION: None
c.

DEFICIENCY: None

d.

PLAN ISSUES: None

e.

NOT DEMONSTRATED: None 79

Unclassified Radiological Emergency Preparedness Program (REP)

After Action Report/Improvement Plan Three Mile Island Nuclear Generating Station

f.

PRIOR ISSUES - RESOLVED: None

g. PRIOR ISSUES - UNRESOLVED: None 3.3.3.4 Franklin County Emergency Operations Center
a.

MET: 1.a. 1, 1.b. 1, 1.c. 1, 1.d. 1, 1.e. 1, 5.b. 1.

b.

AREAS REQUIRING CORRECTIVE ACTION: None

c.

DEFICIENCY: None

d.

PLAN ISSUES: None

e.

NOT DEMONSTRATED: None

f.

PRIOR ISSUES - RESOLVED: None

g.

PRIOR ISSUES - UNRESOLVED: None 3.3.3.5 Franklin County Reception Center, Faust Junior High School

a.

MET: 1.d.1, 1.e. 1, 3.d.1.

b. AREAS REQUIRING CORRECTIVE ACTION: None
c.

DEFICIENCY: None

d. PLAN ISSUES: None
e.

NOT DEMONSTRATED: None

f.

PRIOR ISSUES - RESOLVED: None

g. PRIOR ISSUES - UNRESOLVED: None 3.3.3.6 Franklin County Monitoring and Decontamination Center, Faust Junior High School
a.

MET: 1.e.1, 6.a.1.

b. AREAS REQUIRING CORRECTIVE ACTION: None
c.

DEFICIENCY: None

d. PLAN ISSUES: None
e.

NOT DEMONSTRATED: None

f.

PRIOR ISSUES - RESOLVED: None

g. PRIOR ISSUES - UNRESOLVED: None 80 40

Unclassified Radiological Emergency Preparedness Program (REP)

After Action Report/Improvement Plan Three Mile Island Nuclear Generating Station 3.3.3.7 Schuylkill County Emergency Operations Center

a.

MET: 1.a. 1, 1.c. 1, 1.d. 1, 1.e. 1, 5.b. 1.

b.

AREAS REQUIRING CORRECTIVE ACTION: None

c.

DEFICIENCY: None

d.

PLAN ISSUES: None

e.

NOT DEMONSTRATED: None

f.

PRIOR ISSUES - RESOLVED: None

g.

PRIOR ISSUES - UNRESOLVED: None 3.3.3.8 Schuylkill County Reception Center, Blue Mountain High School

a.

MET: 1.d.1,l.e.1,3.d.1.

b.

AREAS REQUIRING CORRECTIVE ACTION: None

c.

DEFICIENCY: None

d.

PLAN ISSUES: None

e.

NOT DEMONSTRATED: None

f.

PRIOR ISSUES - RESOLVED: None

g.

PRIOR ISSUES - UNRESOLVED: None 3.3.3.9 Schuylkill County Monitoring and Decontamination Center, Blue Mountain High School

a.

MET: 1.e.1, 6.a.1.

b.

AREAS REQUIRING CORRECTIVE ACTION: 6.a. 1.

ISSUE NO.: 64-11-6al-A-09 CRITERION: Reception center/emergency worker facility has appropriate space, adequate resources, and trained personnel to provide monitoring, decontamination, and registration of evacuees and/or emergency workers. (NUREG-0654, J. 10.h.,

K.5.b)

CONDITION: The space set up for hand frisking and initial decontamination of a person that alarmed the portal monitor twice was near the portal monitor, approximately 5 to 6 feet away.

POSSIBLE CAUSE: The set up team for the area did not take into account the distance necessary to ensure the portal monitor would not be affected by nearby 81

Unclassified Radiological Emergency Preparedness Program (REP)

After Action Report/Improvement Plan Three Mile Island Nuclear Generating Station contaminated individuals.

REFERENCE:

NUREG- 0654, K.5.b; Schulykill County Emergency Management Agency Nuclear/Radiological Incident Plan to the County Emergency Operations Plan, Annex A for Nuclear Power Plant Incidents March 1994, A.4, Section L.A.3, page 1 of 45.

EFFECT: The portal monitor could give false indications of contamination when non contaminated individuals pass through.

CORRECTIVE ACTION DEMONSTRATED: The PEMA observer and controller were made aware of the situation and informed the monitoring team that a relocation of the hand frisking operation was necessary. The monitoring of contaminated individuals was re-located closer to the decontamination shower facility and this provided the necessary space to line up additional contaminated individuals without interfering with the portal monitor operation.

c.

DEFICIENCY: None

d. PLAN ISSUES: None
e.

NOT DEMONSTRATED: None

f.

PRIOR ISSUES - RESOLVED: None

g. PRIOR ISSUES - UNRESOLVED: None 3.3.3.10 Schuylkill County Mass Care Center, Blue Mountain High School
a.

MET: 1.e.1,6.a.1,6.c.1.

b. AREAS REQUIRING CORRECTIVE ACTION: None
c.

DEFICIENCY: None

d. PLAN ISSUES: None
e.

NOT DEMONSTRATED: None

f.

PRIOR ISSUES - RESOLVED: None

g. PRIOR ISSUES - UNRESOLVED: None 82 0

Unclassified Radiological Emergency Preparedness Program (REP)

After Action Report/Improvement Plan Three Mile Island Nuclear Generating Station 3.3.4 Private Organizations 3.3.4.1 Exelon Joint Information Center

a.

MET: 1.a.1, 5.b.1.

b.

AREAS REQUIRING CORRECTIVE ACTION: None

c.

DEFICIENCY: None

d.

PLAN ISSUES: None

e.

NOT DEMONSTRATED: None

f.

PRIOR ISSUES - RESOLVED: None

g.

PRIOR ISSUES - UNRESOLVED: None 83

Unclassified Radiological Emergency Preparedness Program (REP)

After Action Reportllmprovement Plan Three Mile Island Nuclear Generating Station SECTION 4: CONCLUSION Based on the review of the offsite radiological emergency response plans and procedures submitted, FEMA Region III has determined they are adequate and there is a reasonable assurance they can be implemented, as demonstrated during the 2011 Three Mile Island Plume Exercise.

84

Unclassified Radiological Emergcncy Preparedness Program (REP)

Three Mile Island Nuclear Generating Station After Action Report/Improvement Plan APPENDIX A: EXERCISE TIMELINE The tables on the following pages present the times at which key events and activities occured during the TMI exercise on April 12, 2011. Also included are times notifications were made to the participating jurisdictions and functional entities.

Table 1 - Exercise Timeline DATE: 2011-04-12, SITE: Three Mile Island Nuclear Generating Station, PA U0 0

Emergency Classification Level or W

Event 0

U 0

0

ý Unusual Event Alert 1712 1724 1733 1726 1724 1735 1724 Site Area Emergency 1840 1848 1857 1854 1854 1903 1848 General Emergency 2007 2016 2018 2023 2024 2016 Simulated Rad. Release Started 1834 1733 1733 1712 1724 1735 1722 Simulated Rad. Release 1840 1848 1900 1848 Terminated Facility Declared Operational 1833 1848 1700 1724 1754 1745 Declaration of State of Emergency 1844 1857 1844 1858 1853 1900 Exercise Terminated 2200 2200 2200 2201 2200 2202 Early Precautionary Actions:

2010 1905 1934 1939 1935 1 st Protective Action Decision:

1944 1912 1920 1910 1 st Siren Activation 1920 1920 1920 1st EAS or EBS Message 1923 1923 1923 2nd Protective Action Decision:

2054 2056 2054 2nd Siren Activation 2104 2104 2104 2nd EAS or EBS Message 2107 2107 2107 3rd Protective Action Decision:

3rd Siren Activation 3rd EAS or EBS Message 4th Protective Action Decision:

4th Siren Activation 4th EAS or EBS Message 5th Protective Action Decision:

5th Siren Activation 5th EAS or EBS Message 6th Protective Action Decision:

6th Siren Activation 6th EAS or EBS Message KI Administration Decision:

2041 2041 2041 2045 2054 2049 85

a Unclassified Radiological Emergency Preparedness Program (REP)

Three Mile Island Nuclear Generating Station After Action Report/Improvement Plan Table 1 - Exercise Timeline DATE: 2011-04-12, SITE: Three Mile Island Nuclear Generating Station, PA U

U 00 0

0 U

U U

Emergency Classification Level or a

Event 0

0 0

0 0

0 UU U

U U

d Unusual Event Alert 1712 1725 1727 1725 1730 1730 1729 Site Area Emergency 1840 1900 1858 1901 1858 1900 1910 General Emergency 2007 2034 2028 2027 2025 2026 2027 Simulated Rad. Release Started 1834 1725 1727 1725 1730 1730 1729 Simulated Rad. Release 1840 1900 1858 1901 1858 1900 1910 Terminated Facility Declared Operational 1805 1745 1757 1815 1803 1747 Declaration of State of Emergency 1910 1852 2005 2009 1920 1910 Exercise Terminated 2155 2204 2054 2145 2206 2105 Early Precautionary Actions:

1923 1st Protective Action Decision:

1920 1919 1923 1914 1915 1st Siren Activation 1st EAS or EBS Message 2nd Protective Action Decision:

2058 2058 2058 2058 2058 2100 2nd Siren Activation 2nd EAS or EBS Message 3rd Protective Action Decision:

3rd Siren Activation 3rd EAS or EBS Message 4th Protective Action Decision:

4th Siren Activation 4th EAS or EBS Message 5th Protective Action Decision:

5th Siren Activation 5th EAS or EBS Message 6th Protective Action Decision:

6th Siren Activation 6th EAS or EBS Message KI Administration Decision:

2058 2057 2054 2053 2054 2100 0

86

Unclassified Radiological Emergency Preparedness Program (REP)

Three Mile Island Nuclear Generating Station After Action Report/Improvement Plan Table 1 - Exercise Timeline DATE: 2011-04-12, SITE: Three Mile Island Nuclear Generating Station, PA w

0 U0 Emergency Classification Level or U

U Event 0

0 0

E U

U-Unusual Event Alert 1712 1725 1725 1917 1738 1741 1741 Site Area Emergency 1840 1847 1848 2035 1903 1907 1907 General Emergency 2007 2012 2030 1929 2031 2032 2034 Simulated Rad. Release Started 1834 1720 1848 1722 1712 1712 Simulated Rad. Release 1840 1840 1858 1840 1840 Terminated Facility Declared Operational 1745 1740 1756 1744 1753 1818 Declaration of State of Emergency 1846 1841 1825 1808 1905 1948 Exercise Terminated 2200 2200 2135 2200 2148 2200 Early Precautionary Actions:

1930 1931 1915 1910 I st Protective Action Decision:

1905 1848 1920 1910 2032 1915 I st Siren Activation 1920 1920 1920 Ist EAS or EBS Message 1923 1923 1923 2nd Protective Action Decision:

2054 2058 2110 2054 2107 2107.

2nd Siren Activation 2104 2104 2104 2nd EAS or EBS Message 2107 2107 2107 3rd Protective Action Decision:

3rd Siren Activation 3rd EAS or EBS Message 4th Protective Action Decision:

4th Siren Activation 4th EAS or EBS Message 5th Protective Action Decision:

5th Siren Activation 5th EAS or EBS Message 6th Protective Action Decision:

6th Siren Activation 6th EAS or EBS Message KI Administration Decision:

2118 2044 2044 2107 2109 2105 87

4 Unclassified Radiological Emergency Preparedness Program (REP)

Three Mile Island Nuclear Generating Station After Action Report/Improvement Plan Table 1 - Exercise Timeline DATE: 2011-04-12, SITE: Three Mile Island Nuclear Generating Station, PA U

U rA Emergency Classification Level or U

Event W4 U

U 0

0 Unusual Event Alert 1712 1745 1744 1741 1740 1746 Site Area Emergency 1840 19I2 1908 1902 1904 1902 General Emergency 2007 2035 2033 2032 2032 2031 Simulated Rad. Release Started 1834 1712 1712 1712 1740 1 740 Simulated Rad. Release 1840 1840 1840 1726 1726 1726 Terminated Facility Declared Operational 1810 1800 1754 1745 1812 Declaration of State of Emergency 2008 1855 1844 1844 1850 Exercise Terminated 2124 2130 2200 2151 2200 Early Precautionary Actions:

1915 1910 1932 Ist Protective Action Decision:

1915 1920 1920 1920 1920 1 st Siren Activation 1st EAS or EBS Message 2nd Protective Action Decision:

2107 2056 2104 2104 2054 2nd Siren Activation 2nd EAS or EBS Message 3rd Protective Action Decision:

3rd Siren Activation 3rd EAS or EBS Message 4th Protective Action Decision:

4th Siren Activation 4th EAS or EBS Message 5th Protective Action Decision:

5th Siren Activation 5th EAS or EBS Message 6th Protective Action Decision:

6th Siren Activation 6th EAS or EBS Message KI Administration Decision:

2100 2056 2039 2038 2054 4

0 88 a

Unclassified Radiological Emergency Preparedness Program (REP)

After Action Report/Improvement Plan Three Mile Island Nuclear Generating Station APPENDIX B: EXERCISE EVALUATORS AND TEAM LEADERS The following is the list of Evaluators and Team Leaders for the TMI 2011 Plume Exercise evaluated on April 12 and 13, 2011. The following consitutes the managing staff for the Exercise Evaluation:

Darrell Hammons, DHS, Radiological Assistance Committee Chairman Matthew Wiedemer, DHS, Exercise Evaluation Program Manager and Site Specialist John Price, DHS, Team Leader, Pennsylvania Emergency Operations Center Richard Kinard, DHS, Team Leader, Dauphin County Emergency Operations Center Martin Vyenielo, DHS, Team Leader, Techinical.Evaluations Bob Neff, DHS, Team Leader, Lancaster County Emergency Operations Center Bart Freeman, DHS, Team Leader, Lebanon County Emergency Operations Center Michael Shuler, DHS, Team Leader, Cumberland County Emergency Operations Center Tina Thomas, DHS, Team Leader, Adams County Emergency Operations Center Dan Lerch, DHS, Team Leader, Franklin County Emergency Operations Center John Price, DHS, Team Leader, Schuylkill County Emergency Operations Center James McClahahan, ICF, Team Leader, Schools Joe Suders. DHS, Team Leader, York County Emergency Operations Center 89

4 Unclassified Radiological Emergency Preparedness Program (REP)

Three Mile Island Nuclear Generating Station After Action Report/Improvement Plan DATE: 2011-04-12, SITE: Three Mile Island Nuclear Generating Station, PA LOCATION EVALUATOR AGENCY Pennsylvania Emergency Operations Center Richard Barkley Nuclear William Palmer Regulatory Chris Thompson Commission, Region I ICF FAA Pennsylvania Joint Information Center David White ICF Pennsylvania Accident Assessment Center, State Emergency Reggie Rodgers ICF Operations Center-Bureau of Radiation Protection

  • Martin Vyenielo FEMA RIII Pennsylvania State Traffic and Access Control Points, State Police Richard Smith ICF Barracks Harrisburg Cumberland County Emergency Operations Center Harry Nash FEMA REP Rosemary Samsel iHQ
  • Michael Shuler ICF Miriam Weston FEMA RIII FEMA R11 Cumberland County Emergency Worker Monitoring and Lawrence Visniesky ICF Decontamination Station, West Shore Fire Station #2, Lemoyne Cumberland County Reception Center, Big Spring High School Tracey Green ICF Cumberland County Monitoring and Decontamination Center, Big Tracey Green ICF Spring High School Cumberland County, New Cumberland Borough Emergency Michael Burriss ICF Operations Center William O'Brien ICF Cumberland County, New Cumberland Borough Back-up Route William O'Brien ICF Alerting Dauphin County Emergency Operations Center Bridget Ahlgrim FEMA HQ James Hickey ICF
  • Richard Kinard FEMA RIJI John Rice FEMA R 1 Dauphin County Emergency Worker Monitoring and Decontamination Reggie Rodgers ICF Station, Harrisburg Area Community College Dauphin County Mass Care Center, Lenkerville Elementary School Carl Wentzell ICF Dauphin County Mass Care Center, Halifax Area High School John Wills ICF Dauphin County, Harrisburg City Emergency Operations Center Frank Cordaro ICF Dauphin County, Highspire Borough Emergency Operations Center Mark Dalton ICF Robert Jeffries ICF Dauphin County, Highspire Back-up Route Alerting Robert Jeffries ICF Dauphin County, Londonderry Township Emergency Operations Steve Denson ICF Center Dauphin County, Paxtang Borough Emergency Operations Center DeeEll Fifield ICF Dauphin County, LowerPaxton Township Emergency Operations Clark Duffy ICF Center Dauphin County, South Hanover Township Emergency Operations Robert Vork ICF Center Lancaster County Emergency Operations Center
  • Robert Neff FEMA RI1I Lancaster County Emergency Worker Monitoring and Alan Bevan ICF Decontamination Station, Mount Joy Fire Department Lancaster County Mass Care Center Conestoga Valley High School
  • Joseph Suders FEMA RIII Lancaster County Mass Care Center, Conestoga Valley Middle School *Joseph Suders FEMA Rill Lancaster County Reception Center, Park City Mall Michael Bums ICF 4

a 90 a

Unclassified Radiological Emergency Preparedness Program (REP)

Three Mile Island Nuclear Generating Station After Action Report/Improvement Plan Lancaster County Monitoring and Decontamination Center, Manheim Samuel Nelson ICF Township School Complex Lancaster County Mass Care Center,Cocalico Middle School Joseph Suders FEMA RIJI Lancaster County, Cocalico High School,Mass Care Center Joseph Suders FEMA RIII Lancaster County Mass Care Center, Manheim Township Middle Samuel Nelson ICF School Lancaster County Mass Care Center, Warwick High School

  • Robert Neff FEMA RIll Lancaster County Mass Care Center, Warwick Middle School
  • Robert Neff FEMA RIII Lancaster County, Conoy Township Emergency Operations Center Marcy Campbell ICF Lancaster County, Conoy Township Back-Up Route Alerting Marcy Campbell ICF Lancaster County, East Donegal Township Emergency Operation Thomas Gahan ICF Center Michael Petullo ICF Lancaster County, East Donegal Township Back-up Route Alerting Michael Petullo ICF Lancaster County, Elizabethtown Borough/West Donegal Robert Duggleby ICF Township/Mount Joy Township. Emergency Operations Center Danny Loomis ICF Lancaster County, Elizabethtown Borough Traffic and Access Control Stephen Watts ICF Lancaster County, Susquehanna Regional Police Department Traffic Meg Swearingen ICF and Access Control Lebanon County Emergency Operations Center

-. Jon Christiansen ICF Lashawn Halsey FEMA HQ Daniel Lerch FEMA RIIl Lebanon County Emergency Worker Monitoring and Decontamination Marcy Campbell ICF Station, Annville Union Hose Fire Department David Petta ICF Lebanon County Reception Center, Lebanon. County Career and Earl Shollenberger ICF Technological Center Lebanon County Monitoring and Decontamination Center, Lebanon Earl Shollenberger ICF County Career and Technological Center Lebanon County Mass Care Center, Northern Lebanon High School Richard McPeak ICF Lebanon County, South Londonderry Township Emergency James Greer ICF Operations Center Bart Ray ICF Lebanon County, South Londonderry Township, Back-Up Route Bart Ray ICF Alerting Lebanon County, South Londonderry Township Traffic and Access David Stuenkel ICF Control York County Emergency Operation Center Eric Carter ICF Tina Lai Thomas FEMA RIIl Kent Tosch ICF York County Emergency Worker Monitoring and Decontamination Ronald Biernacki ICF Station, Monaghan Fire Department York County Reception Center, Southern School Complex Bruce Swiren ICF York County Monitoring and Decontamination Center, Southern Bruce Swiren ICF School Complex High School York County Mass Care Center, Southern School Complex Bruce Swiren ICF York County, Dover Township Emergency Operations Center David Kayen ICF York County, Lewisbury Borough/Newberry Township Emergency Roger Jobe ICF Operations Center H. Wes Ryals ICF York County, Newberry Township Back-up Route Alerting H. Wes Ryals ICF York County, Manchester Township Emergency Operations Center Larry Broockerd FEMA HQ York County, Northeast Area Emergency Operations Center (Mount John Flynn ICF Wolf, Manchester Borough, E Manchester Township)

Franklin County Mass Care Center, Faust Junior High School Kenneth Wierman FEMA HQ 91

Unclassified Radiological Emergency Preparedness Program(REP)

Three Mile Island Nuclear Generating Station After Action Rcport/Improvement Plan Dauphin County, Capital Area Intermediate Unit, Administration Earl Shollenberger ICF Building Dauphin County, Capital Area Intermediate Unit, Capital Area School Earl Shollenberger ICF for the Arts Dauphin County, Central Dauphin School District William O'Brien ICF Dauphin County, Central Dauphin School District, Central Dauphin William O'Brien ICF East High School Dauphin County, Central Dauphin School District, Swatara Middle Robert Jeffries ICF School Dauphin County, Central Dauphin School District, Tri Community David Petta ICF Elementary School Dauphin County, Derry Township School District Richard Smith ICF Dauphin County, Derry Township School District, Hershey Richard Smith ICF Intermediate Elementary School Dauphin County, Derry Township SchoolDistrict, Hershey Middle Carl Wentzell ICF School Dauphin County, Harrisburg School District Samuel Nelson ICF Dauphin County, Harrisburg School District, Harrisburg High School Samuel Nelson ICF Dauphin County, Harrisburg School District, Scott School Ronald Biemacki ICF Dauphin County, Harrisburg School District, Shimmell School Rosemary Samsel ICF Dauphin County, Lower Dauphin School District Kenneth Wierman FEMA HQ Dauphin County, Lower Dauphin School District, Lower Dauphin Kenneth Wierman FEMA HQ High School Dauphin County, Lower Dauphin School District, Price Building John Wills ICF Dauphin County, Lower Dauphin School Distirct, South Hanover Richard McPeak ICF Elementary School Dauphin County, Middletown Area School District James Hickey ICF Dauphin County, Middletown Area School District, Middletown High James Hickey ICF School Dauphin County, Milton Hershey School Paul Nied ICF Dauphin County, Steelton-Highspire School District Alan Bevan ICF Dauphin County, Steelton-Highspire School District, Steelton-Alan Bevan ICF Highspire High School Lancaster County, Donegal School District Michael Petullo ICF Lancaster County, Donegal School District, Donegal High School Michael Petullo ICF Lancaster County, Donegal School District, Donegal Springs Tracey Green ICF Elementary School Lancaster County, Elizabethtown Area School District Stephen Watts ICF Lancaster County, Elizabethtow Area School District, East High Street Kent Tosch ICF Elemementary School Lancaster County, Elizabethtown Area School District, Fairview Robert Black ICF Elementary School Lancaster County, Elezabethtown Aera School District, Mill Road Stephen Watts ICF Elementary School Lebanon County, Palmyra Area School District Bart Ray ICF Lebanon County, Palmyra Area School District, Palmyra High School Bart Ray ICF York County, Central York School District H. Wes Ryals ICF York County, Central York School District, Central York Middle H. Wes Ryals ICF School York County, Central York School District, Hayshire Elementary John Zeidler ICF School 0

0 92

Unclassified Radiological Emergency Preparedness Program (REP)

Three Mile Island Nuclear Generating Station After Action Report/Improvement Plan York County, Central York School District, Roundtown Elementary Bruce Swiren ICF School York County, Dover Area School Distriict David Stuenkel ICF York County, Dover Area School District, Dover Intermediate School David Stuenkel ICF York County, Eastern York School District David White ICF York County, Eastern York School District, Kreutz Creek Elementary David White ICF School York County, Northeastern School District Lawrence Visniesky ICF York County, Northeastern School District, Northeastern Middle Lawrence Visniesky ICF School York County, Northeastern School District, Shallow Brook William Palmer ICF Intermediate School, York County, Northeastern School District, Spring Forge Intermediate John Flynn ICF School York County, Northeastern School District, York Haven Elementary Meg Swearingen ICF School York County, West Shore School District Lynn Steffensen ICF York County, West Shore School District, Allen Middle School Eric Carter ICF York County, West Shore School District, Cedar Cliff High School

  • Roger Kowieski NTHMC York County, West Shore School District, Highland Elementary Michael Bums ICF School York County, West Shore School District, New Cumberland Middle James McClanahan ICF School York County, West Shore School District, Red Mill Elementary, Lynn Steffensen ICF School Lebanon County, Eastern Lebanon High School Complex
  • Joseph Suders FEMA RIl Cumberland County Mass Care Center, Big Spring High School Tracey Green ICF Lancaster County Mass Care Center, Manheim Township High School *Robert Neff FEMA Rill Adams County Emergency Operations Center Barbara Thomas FEMA RI Franklin County Emergency Operations Center Taneeka Hollins FEMA HQ Franklin County Reception Center, Faust Junior High School Kenneth Wierman FEMA HQ Franklin County Monitoring and Decontamination Center, Faust Kenneth Wierman FEMA HQ Junior High School Schuylkill County Emergency Operations Center Robert Black ICF Schuylkill County Reception Center, Blue Mountain High School John Zeidler ICF Schuylkill County Monitoring and Decontamination Center, Blue John Zeidler ICF Mountain High School Schuylkill County Mass Care Center, Blue Mountain High School John Zeidler ICF Exelon Joint Information Center Paul Nied ICF
  • Team Leader 93

4 Unclassified Radiological Emergency Preparedness Program (REP)

Three Mile Island Nuclear Generating Station After Action Report/Improvement Plan APPENDIX C: ACRONYMS AND ABBREVIATIONS AAC Accident Assessment Center ACP Access Control Points AMS Allen Middle School ANS Automated Notification System ARC American Red Cross ARCA Area Requiring Corrective Action ARDS Automatic Ring Down System ARES Amateur Radio Emergency Service AS Assistant Superintendent CAD Computer Aided Dispatch CART County Animal Response Team CDMS Central Dauphin Middle School CDSD Central Dauphin School District CMT Crisis Management Team CSC Customer Service Center DCEMA Dauphin County Emergency Management Agency DCEOC Dauphin County Emergency Operations Center DEMD Deputy Emergency Management Director DRD Direct Reading Dosimetrv EAL Emergency Action Level EAS Emergency Alert System ECC Emergency Communications Center ECL Emergency Classification Level EDACS Emergency Direct Access Communications System ELCMS East Lebanon County Middle School ELCSC Eastern Lebanon County School Complex EM Emergency Manager EMA.

Emergency Management Agency EMC Emergency Management Coordinator EMD Emergency Management Director EMS Emergency Medical Service EMSO Emergency Medical Services Officer EOC Emergency Operations Center EOF Emergency Operations Facility 4

4 94 4

Unclassified Radiological Emergency Preparedness Program (REP)

Three Mile Island Nuclear Generating Station After Action Report/Improvement Plan EOP Emergency Operations Plan EPA Environmental Protection Agency EPZ Emergency Planning Zone ERDS Emergency Response Data System ESF Emergency Support Function EW Emergency Workers EWEC Emergency Worker Exposure Control FD Fire Department FDMJ Fire Department Mount Joy FEMA Federal Emergency Management Agency FSO Fire Services Officer GE GENERAL EMERGENCY GIS Geographic Information System HACC Harrisburg Area Community College HF High Frequency HMC Hershey Medical Center HMT Hazardous Materials Team HPD Highspire Police Department IMAT Incident Management Assistance Team JIC Joint Information Center LC Lebanon County LCEMA Lebanon County Emergency Management Agency LCEOC Lancaster County Emergency Oerations Center LCEOP Lebanon County Emergency Operations Plan LDHS Lower Dauphin High School LDMS Lower Dauphin Middle School LDSD Lower Dauphin School District LPT Lower Paxton Township LT Londonderry Township LTEOC Londonderry Township Emergency Operations Center MAHS Middletown Area High School MHS Milton Hershey School MOC Media Operations Center MS Middle School MSC Medical Services Coordinator MTCCC Mannheim Township Congregate Care Center MTERP Manchester Township Emergency Response Plan MTMS Mannheim Township Middle School NARS Nuclear Accident Reporting System NCMS New Cumberland Middle School 95

a Unclassified Radiological Emergency Preparedness Program (REP)

Three Mile Island Nuclear Generating Station After Action Report/Improvement Plan NGS Nuclear Generating Station NIMS National Incident Management System NPP Nuclear Power Plants NRC Nuclear Regulatory Commission NWS National Weather Service ORO Offsite Response Organization PA Public Address.

PAD Protective Action Decisions PAR Protective Action Recommendation PASD Palmyra Area School District PD Police Department PEMA Pennsylvania Emergency Management Agency PGSD Pine Grove School District PHS Palmyra High School PHVFD Pleasant Hall Volunteer Fire Department P1O Public Information Officer PRD Permanent Record Dosimeter PSC Police Services Coordinator PSP Pennsylvania State Police RAC Radiological Assistance Committee RACES Radio Amateur Civil Emergency Services RAT Route Alerting Team RCRS Road Condition Reporting System REP Radiological Emergency Preparedness RERP Radiological Emergency Response Plan RIRP Radiological Incident Response Plan RO Radiological Officer RSAN Roam Security Alert Network SAE SITE AREA EMERGENCY SBIS Shallow Brook Intermediate School SCRA Schuylkill County Repeater Association SD School District SEOC State Emergency Operation Center SEVAN State Emergency Voice Activated Network SLO State Liaison Officer SLT South Londonderry Township SOP Standard Operating Procedure SPERT Special Police Emergency Response Team SSO Senior State Official TC Transportation Coordinator a

a 96 a

Unclassified Radiological Emergency Preparedness Program (REP)

Three MileIsland Nuclear Generating Station After Action Report/Improvement Plan TCP Traffic Control Points TEDE Total Effective Dose Equivalent TMI Three Mile Island TMINGS Three Mile Island Nuclear Generating Station TMINPS Three Mile Island Nuclear Power Station TNS Telephone Notification System WSSD West Shore School District YCEOC York County Emergency Operations Center 97

a Unclassified Radiological Emergency Preparedness Program (REP)

Three Mile Island Nuclear Generating Station After Action Report/improvement Plan

..APPENDIXD:EXERCISE-PLAN The enclosed Exercise Plan wiascreated as an overall tool for facilitation and implementation of

.the TMI 2011 Plume~Exercise and to integratethe concepts and policies of the Homeland Security Exercise EvaluationiProgram'with tieiRadiological Eme' gency. Preparedness Program Exercise Methodology. The Exercise Planiva0originally drafted and published by the Pennsylvania Emergency Agency (PEMA. as a independent document arid is annexed here.

0 a

98 a

Unclassified Radiological Emergency Preparedness Program (REP)

After Action Report/Improvement Plan Three Mile Island Nuclear Generating Station E

e an I-,

cise0~

Exr is Dae 4/21 FE3~bihn Dae 63

  • 5 Y

a Unclassified Radiological Emergency Preparedness Program (REP)

After Action Report/Improvement Plan Three Mile Island Nuclear Generating Station Radiological Emergency Preparedness (REP)/

Homeland Security;Exercise:andEvaluation Program (HSEEP)

ExPlan 2011 THREE MILEISLAND PLUME, EXERCISE PREFACE The 2011 Three Mile Island Plume Exercise Evaluated Full Scale Exercise (FSE) is sponsored by the Federal Emergency Management Agency (FEMA) and the Pennsylvania Emergency Management Agency (PEMA). 'This Exercise Plan (ExPlan) was produced with input, advice, and assistance from the Exercise Planning Team (EPT), which followed the guidance set forth in the Federal Emergency Management Agency, Homeland Security Exercise and Evaluation Program (HSEEP).

The ExPlan gives officials, observers, media personnel, and players from participating organizations the information necessary to observe or participate in a nuclear power plant accident response exercise focusing on participants' emergency response plans, policies, and procedures as they pertain to this type of event. The information in this document is current as of the date of publication and is subject to change as dictated by the Exercise Planning Team.

The 2011 Three Mile Island Plume Exercise is an unclassified exercise. The control of information is based more on public sensitivity regarding the nature of the exercise than on the actual exercise content. Some exercise material is intended for the exclusive use of exercise planners, Controllers, and Evaluators, but Players may view other materials deemed necessary for their performance. The ExPlan may be viewed by all exercise participants, but the Controller and Evaluator (C/E) Handbook is a restricted document intended for Controllers and Evaluators only.

All exercise participants should use appropriate guidelines to ensure the proper control of information within their areas of expertise and to protect this material in accordance with current jurisdictional directives. Public release of exercise materials to third parties is at the discretion of DHS and the EPT.

100 6

Unclassified Radiological Emergency Preparedness Program (REP)

After Action Report/Improvement Plan Three Mile Island Nuclear Generating Station HANDLINGINSTRUCTiONS

1. The title of this document is the 2011 Three Mile Istand Plume Exercise Plan (ExPlan).
2. The information gathered in this ExPlan is For Official Use Only (FOUO) and should be handled as sensitive information not to be disclosed. This documert should be safeguarded, handled, transmitted, and stored in accordance with appropriate security directives. Reproduction of this document, in whole or in part, without prior approval from the Exercise Planning Director is prohibited.
3. At a minimum, the attached materials will be disseminated only on a need-to-know basis and when unattended, will be stored in a locked container or area offering sufficient protection against theft.,

compromise, inadvertent access, and unauthorized disclosure.

4. For more information, please consult the following points of contact (POCs):

Federal POC(s):

Matt Wiedemer Emergency Management Program Specialist Federal Emergency Management Agency 615 Chestnut Street Philadelphia, Pa 19106-4404 215-931-5659 mathew.wiedemer@dhs.gov State POC(s):

Jesse Wells Emergency Management Specialist Pennsylvania Emergency Management Agency 2605 Interstate Drive Harrisburg, Pa. 17110 717-651-2190 jewells@state.pa.us ORO POC(s):

Laurin Fleming Emergency Management Specialist Pennsylvania Emergency Management Agency 2605 Interstate Drive Harrisburg, Pa. 17110 717-651-2119 laufleming@state.pa.us 101

Unclassified Radiological Emergency Preparedness Program (REP)

After Action Report/Improvement Plan Three Mile Island Nuclear Generating Station TABLE OF CONTENTS Exercise Plan.................................................................................................

99 Preface............................................................................................................

100 Handling Instructions.....................

101 Chapter 1: General Information.....................................................................

104 Introd uctio n...........................................................................................

104 C o nfide ntia lity........................................................................................ 104 P u rp o se.................................................................................................

10 4 T arget C apabilities..........................................................................

...... 105 Exercise O bjectives..................................

............................................... 106 Chapter 2: Exercise Logistics.....................................................

I................... 107 Exercise Summary...............................................

107 G en eral................................................................................................................................

10 7 Assumptions..........................................

107- '

C onstructs and C onstraints.................................................................................................

108 Controller and Evaluator Handbook...................................................................................

109 M aster Scenario E vents L ist...............................................................................................

110 Exercise Implementation.......................................................................... 110 E x ercise P lay.......................................................................................................................

110 E x ercise R u les.....................................................................................................................

1 10 G en era l................................................................................................................................

Ill E x ercise S etu p.....................................................................................................................

111 Accident Reporting and Real Emergencies.................................................. 111 S ite A ccess.............................................................................................

1 12 S ecu rity...............................................................................................................................

1 12 O bserver C oordination........................................................................................................

113 Parking and D irections........................................................................................................

113 R estroom F acilities.............................................................................................................

113 Exercise Identification............................................................................. 113 C om m unications Plan..............................................................................

113 Exercise Start, Suspension, and Termination Instructions..................................................

113 P layer C om m unication........................................................................................................

114 P layer B riefing....................................................................................................................

114 P u b lic A ffairs......................................................................................................................

1 14 Chapter 3: Player Guidelines.........................................................................

115 Exercise S taff.........................................................................................

115 E x ercise D irector................................................................................................................

1 15 T ru sted A gents....................................................................................................................

115 C o n tro llers...........................................................................................................................

1 15 E v alu ato rs...........................................................................................................................

1 16 102

Unclassified Radiological Emergency Preparedness Program (REP)

After Action Report/Improvement Plan Three Mile Island Nuclear Generating Station Player Instructions......................................................

116 Before the Exercise 116 During the Exercise...............

................................. 117 Following the Exercise 117 Simulation Guidelines 118 Chapter 4: Evaluation' and Post-Exercise ActiVities................ 119 Exercise Documentatin...

119 Exercise Evaluation G uides................................................................................................

119 D e b riefin g...............................................................................

............. 1 19 Controller and Evaluator Hotwash.........................

.............................. 119 Participants and Public/Media Briefings...................................................... 119 After Action Report............

120 After Action 'Conference and Improvement Plan

120, A fter A ction C onference.....................................................................................................

120 Im provem ent Plan................................................................

........................................... 120 Appendix A: Exercise Schedule....................................................................

121 103

Unclassified Radiological Emergency Preparedness Program (REP)

After Action Report/Improvement Plan Three Mile Island Nuclear Generating Station CHAPTER 1: GENERAL INFORMATION Introduction The 2011 Three Mile Island Plume Exercise is a full-scale exercise (FSE) designed to establish a learning environment for players to exercise emergency response plans, policies, and procedures as they pertain to Nuclear Power Plant accidents. An FSE is a complex event that requires detailed planning. To conduct an effective exercise, subject matter experts (SMEs) and local representatives from numerous agencies have taken part in the planning process and will take part in exercise conduct and evaluation.

This Exercise Plan (ExPlan) was produced at the direction of the Federal Emergency Management Agency and the Pennsylvania Emergency Management Agency with the input, advice, and assistance of the Exercise Planning Team. The 2011 Three Mile Island Plume Exercise is evidence of the growing partnership between State and local jurisdictions for response to the threats our Nation and communities face.

Confidentiality The 2011 Three Mile Island Plume Exercise is an unclassified exercise. The control of information is based more on public sensitivity regarding the nature of the exercise than on the actual exercise content. Some exercise material is intended for the exclusive use of exercise planners, controllers, and evaluators, but players may view other materials deemed necessary to their performance. This ExPlan may be viewed by all, exercise participants, but the Controller and Evaluator (C/E) Handbooks are restricted documents intended for controllers and evaluators only.

All exercise participants should use appropriate guidelines to ensure the proper control of information within their areas of expertise and protect this material in accordance with current Federal Emergency Management Agency and the Pennsylvania Emergency Management Agency directives.

Public release of exercise materials to third parties is at the discretion of the Federal Emergency Management Agency (FEMA) and the Exercise Planning Team.

Purpose The purpose of this exercise is to evaluate player actions against current response plans and capabilities for a nuclear power plant-related incident, and to comply with the requirements of 44 CFR 350 and the guidelines of NUREG 0654/FEMA-REP-1. Exercise planners utilized the elements described in the 67 FR 20580 (April 25, 2002) and Interim Radiological Emergency Preparedness (REP) Program Manual (August 2002) to develop this exercise.

104 4

Unclassified Radiological Emergency Preparedness Program (REP)

After Action Report/Improvement Plan Three Mile Island Nuclear Generating Station The objective of the Federal Emergency Management Agency and the Pennsylvania Emergency Management Agency is to demonsrate reasonablb:k ssurrance that the public can be protected during a nuclear power plant emergency.

Target Capabilities The establishment of the National Preparedness Priorities.have steered the focus of homeland security toward a capabilities-based planning approach. Capabilities-based planning focuses on planning under uncertainty, since the next danger or disaster can never be forecast with complete accuracy. Therefore, capabilities-based planning takes an all-hazards approach to planning and preparation which builds capabilities that can be applied to a wide variety of incidents. States and Urban Areas use capabilities-based planning to identify a baseline assessment of their homeland security efforts by comparing their current capabilities against the Target Capabilities List (TCL) and the critical tasks of the UniversalTask List (UTL). This approach identifies gaps in current capabilities and focuses efforts On identifying and developing priority capabilities and tasks for the jurisdiction. These priority capabilities are articulated in the jurisdiction's homeland security strategy and Multi-Year Training and Exercise Plan (TEP), of Which this exercise is a component of.

The capabilities listed below have been selected by the Exercise Planning Team (EPT) from the priority capabilities identified in Pennsylvania Multi-Year TEP and the FEMA Interim Radiological Emergency Preparedness Program Manual (August 2002), Exercise Evaluation Criteria. These capabilities provide the foundation for development of the exercise objectives and scenario, as the purpose of this exercise is to measure and validate performance of these capabilities and theirassociatedcritical tasks.

" Communications Emergency Operations Center Management

" Responder Safety and Health

" Public Safety and Security Response

" WMD/HazMat Response and Decontamination Citizen Evacuation and Shelter-In-Place Emergency Public Information and Warning Mass Care (Sheltering, Feeding, andRelated Services) 105

d Unclassified Radiological Emergency Preparedness Program (REP)

Three Mile Island Nuclear Generating Station After Action Report/Improvement Plan Exercise Objectives The Emergency Preparedness Evaluation Areas - the elements and sub-elements - for this exercise are those that are required to be demonstrated in every exercise, as required by 67 FR 20580 (April 25, 2002) and the Interim REP Program Manual (August 2002). Appendix B Extent of Play shows the emergency preparedness elements that are required to be demonstrated in the 2011 Three Mile Island Plume Exercise, along with the level of demonstration that will be displayed in the exercise (i.e., fully demonstrated, limited demonstration, simulated, out-of-sequence interviews, not demonstrated).

The objective of this exercise is to demonstrate reasonable assurance that the health and safety of the public can be protected, through successful demonstration of tasks identified in Appendix B.

Outstanding Issues There is one Area Requiring Corrective Action (ARCAs) as a result of the FEMA-evaluated plume-phase exercise at Three Mile Island in April 2009:

COUNTY ARCA FACILITY EVALUATED NUMBER Lancaster 64-09-3.a.1A-03 Conoy Township backup route alerting team members were receiving a radiological brief and being issued dosimetry when the notification of a failed siren was received at the Conoy Emergency Operations Center, delaying the start of their runs for 15 minutes.

4 4

106 4

Unclassified Radiological Emergency Preparedness Program (REP)

After Action Report/Improvement Plan Three Mile Island Nuclear Generating Station CHAPTER 2: EXERCISE LOGISTICS Exercise Summary General The 2011 Three Mile Island Plume Exercise is designed to establish a learning environment for players to exercise their plans and procedures for responding to an incident at a nuclear power plant. The 2011 Three Mile Island Plume Exercise will be conducted on April 12, 2011. Out of sequence evaluations will be conducted as follows:

Schools - April 12th.

Pennsylvania State Police - April 12th Emergency Worker Monitoring & Decontamination - April 13th Reception Centers - April 13th Mass Care Shelters - April 13th Exercise play on April 12th is scheduled to end at 2200 hours0.0255 days <br />0.611 hours <br />0.00364 weeks <br />8.371e-4 months <br /> or before. The exercise may conclude when the Lead Controller in consultation with FEMA and the Utility determine that the exercise objectives have been met at each venue.

Assumptions Assumptions constitute the implied factual foundation for the exercise and, hence, are assumed to be present before the start of the exercise. The following general assumptions apply to the 2011 Three Mile Island Plume Exercise:

" The exercise will be graded against the REPP criteria. Elements outside the scope of the REP criteria will not be graded.

  • This exercise will be conducted in a no-fault learning environment wherein systems and processes, not individuals, will be evaluated.

" Exercise simulation will be realistic and plausible, containing sufficient detail from which to respond.

" Exercise players will react to the information and situations as they are presented, in the same manner as if this had been a real event.

107

Unclassified Radi6logical Emergency Preparedness Program (REP)

After Action Report/lmpro*cment Plan Three Mile Island Nuclear Generating Station Constructs and Constraints Constructs are exercise devices designed to enhance or improve exercise realism. Alternatively, constraints are exercise limitations that may detract from exercise realism. Constraints may be the inadvertent result of a faulty construct or may pertain to financial and staffing issues.

Although there are a number of constructs and constraints (also known as exercise artificialities) for any exercise, the EPT recognizes and accepts the following as necessary:

  • Players will utilize normal, everyday communications methods, channels, and equipment.
  • Out-of-Sequence play is allowed.
  • Certain simulations are allowed.

The participating agencies may need to balance exercise play with real-world emergencies. It is understood that real-world emergencies will take priority.

Exercise Participants The following are the categories of participants involved in this exercise; note that the term "participant" refers to all categories listed below, not just those playing in the exercise:

" Players. Players are agency personnel who have an active role in responding to the simulated emergency and perform their regular roles and responsibilities during the exercise. Players initiate actions that will respond to and mitigate the simulated emergency.

  • Controllers. Controllers set up and operate the exercise site; plan and manage exercise play; act in the roles of response individuals and agencies not playing in the exercise.

Controllers direct the pace of exercise play and routinely include members from the exercise planning team. They provide key data to players and may prompt or initiate certain player actions to ensure exercise continuity.

" Simulators. Simulators are control staff personnel who role-play as nonparticipating organizations or individuals. They most often operate out of the Simulation Cell (SimCell), but may occasionally have face-to-face contact with players. Simulators function semi-independently under the supervision of the Lead Controller, enacting roles (e.g., as media reporters or next of kin) in accordance with instructions provided in the Master Scenario Events List (MSEL). All simulators are ultimately accountable to the Lead Controller. For this exercise, the SimCell will be restricted to the Rumor Control Function.

108 a

Unclassified Radiological Emergency Preparedness Program (REP)

After Action Report/Improvement Plan Three Mile Island Nuclear Generating Station

" Evaluators. Evaluators are chosen to evaluate and provide feedback on a designated functional area of the exercise. They are chosen based on their expertise in the functional area(s) they have been assigned to review during the exercise and their familiarity with local emergency response procedures. Evaluators assess'and document players' performance against established emergency' plans and exercise evaluation' Criteria, in accordance with HSEEP standards and within the bounds of REP Program guidance and regulations. They are typically chosen from aniongst planning committee members or the agencies/organizations that are participating in the exercise. FEMA evaluators are members of the Region III REP Program staff, representatives of the Radiological Assistance Committee, and contractors. FEMA Evaluators':will not serve as Controllers.

" Actors. Actors are exercise participants who act or simulate Specific roles during exercise play. They are typically volunteers who have been recruited to play the role of victims or other bystanders.

" Observers. Observers visit or view selected segments of the exercise. Observers do not play in the exercise, and do not perform any control or evaluation functions. Observers will view the exercise from a designaied 'observation area and will be asked to remain within the observation area during the exercise. PEMA observers will be present at selected locations as assigned by the Lead Controller. PEMA observers will receive an observer briefing prior to the day of the exercise. Any, V.I.P.s or other visitors will be handled by each agency or location (Municipal EOC, County EOC, etc.) according to that agencies policies and procedures.

  • Media Personnel. Some media personnel may be present as observers pending approval by the Exercise Director in coordination with*'the PEMA Press Office. Media interaction may also be simulated by Actors 'at the Joint Information Center during the simulated press briefing to enhance realism and meet related exercise objectives.
  • Support Staff Exercise support staff includes individuals who are assigned administrative and logistical support tasks during the exercise (i.e. registration, catering, etc.

Exercise Tools Controller and Evaluator Handbooks The 2011 Three Mile Island Plume Exercise Controller and Evaluator Handbooks are designed to help exercise Controllers and Evaluators conduct and evaluate an effective exercise. These Handbooks also enable Controllers and Evaluators to understand their roles and responsibilities in exercise execution and evaluation. Should a Player, Observer, or media representative find an unattended Handbook, it should be provided to the nearest Controller or Evaluator.

109

Unclassified Radiological Emergency Preparedness Program (REP)

After Action Rcport/Improvement Plan Three Mile Island Nuclear Generating Station Master Scenario Events List The MSEL outlines benchmarks, as well as injects that drive exercise play. It also details realistic input to the exercise players as well as information expected to emanate from simulated organizations (i~e., those nonparticipating organizations, agencies, and individuals who would usually respond to the situation). An inject will include several itemsof information, such as inject time, intended recipient, responsible controller, inject type, a short description of the event, and the expected player action.

For the 2011 Three Mile Island Plume Exercise the MSEL will be used primarily for out of sequence exercise play. During the plume phase the exercise will be driven by the simulator at the utility. Notifications will go out from the utility in the same manner as they would in a real event with all communications being preceded and terminated by the phrase "This is a Drill".

Additionally, Bureau of Radiation Protection (BRP) field teams will be utilizing "exercise measuring instruments" that receive input from the Virtual Plume software. The Virtual Plume software will be programmed to reflect expected conditions at any given time during the exercise.

Exercise Implementation Exercise Play Exercise play will begin at approximately 1630 hours0.0189 days <br />0.453 hours <br />0.0027 weeks <br />6.20215e-4 months <br /> with a situation update going to each participating venue. Play will proceed according to the events outlined in the MSEL, in accordance with established plans and procedures. The exercise will conclude upon the completion of operations and attainment of the exercise objectives, as determined by the Lead Controller after consultation with FEMA and the Utility.

Exercise Rules The following are the general rules that govern exercise play:

  • Real-world emergency actions take priority over exercise actions.
  • Exercise participants will comply with real-world response procedures, unless otherwise directed by control staff.

" All communications (written, radio, telephone, etc.) made during the exercise will begin and end with the phrase, "This is a drill."

Exercise participants placing telephone calls or initiating radio communication with the SimCell must identify the organization, agency, office, and/or individual with whom they wish to speak.

110 4

Unclassified Radiological Emergency Preparedness Program (REP)

After Action Report/Improvement Plan Three Mile Island Nuclear Generating Station Safety Requirements General Exercise participant safety takes priority.over exercise events. Although the organizations involved in the 2011 Three Mile Island Plume Exercise. come from various response agencies, they share the basic responsibility for ensuring a. safe environment for all personnel involved in the exercise. In addition, aspects of an emergency response are dangerous. Professional health and safety ethics should guide all participants to operate in their assigned roles in the safest manner possible. The following general requirements apply to the exercise:

An exercise Safety Controller will be identified and be responsible for participant safety.

  • All exercise controllers, evaluators, and staff will serve~as safety observers while the exercise activities are underway. Any safety' 6onrcems must be immediately reported to the Safety Controller..
  • Participants will be responsible for their own and each other's safety during the exercise.

It is the responsibility of all persons associated with the exercise to stop play if, in their opinion, a real safety problem exists. Once the problem is corrected, exercise play can be restarted.

  • All organizations will comply with their respective environmental, health, and safety plans and procedures, as well as the appropriate Federal, State, and local environmental health and safety regulations.

Exercise Setup Exercise setup involves the pre-staging and dispersalof exercise materials; including registiation materials, documentation, signage, and other equipment as appropriate.

Accident Reporting and Real Emergencies

  • Anyone observing a participant who is seriously ill or injured will provide aid within their training, call the County 911 Center for additional aid or enlist the aid of another person to call, and advise the nearest controller. Anyone calling County 911 will use the phrase "this is not a drill" prior to explaining the injury or illness.
  • The controller who is made aware of a real emergency will contact the County 911 center (if this call has not already been made) and request the appropriate aid. The controller will use the phrase "this is not a drill" prior to explaining the injury or illness.

111

Undassifled Radiological Emergency Preparedness Program (REP)

After Action Report/Improvement Plan Three Mile Island Nuclear Generating Station The controller will'then contact the Lead Controller and Exercise Director with the following information:

o Venue/function o

Location within the venue/function o

Condition of injured parties o

Requirements for medical aid, fire suppression, rescue, or security resources.

If the nature of the emergency requires a suspension of the exercise at the venue/function, all exercise activities at that facility will immediately cease. Exercise play may resume at that venue/function once the emergency situation has been addressed.

Exercise play at other venue/functions should not cease if one venue/function has declared a "Real-World Emergency" unless they are reliant on the affected venue.

If a real emergency occurs that affects the entire exercise, the exercise may be suspended or terminated at the discretion of the Exercise Director and Lead Controller. The notification will be made from the State Emergency Operations Center. The Lead Controller will notify the SimCell by phone.

Site Access Security Exercise play for the 2011 Three Mile Island Plume Exercise will be. conducted at numerous sites with varying degrees of security requirements. The Three Mile Island will control entry to the Utility and the Emergency Operations Facility. Security at State, County, and Municipal Emergency Operations Centers will be conducted according to their individual security procedures. Individual Site Controllers will be in charge of entry into their respective exercise sites. To prevent confusion and interruption of the exercise, access to the exercise sites and the SimCell will be limited to exercise participants and approved Observers only. Players should advise their venue's controller or evaluator if an unauthorized person is present. Each organization should follow its internal security procedures, augmented as necessary to comply 4

with exercise requirements.

PEMA Observers and Liaison Officers PEMA will assign Observers and Liaison Officers to each County and Municipal Emergency Operations Center that is being evaluated in the 2011 Three Mile Island Plume Exercise. The Lead Controller will provide a list of Observers and Liaison Officers to the appropriate Off-Site Response Organizations prior to the day of the exercise. All Observers and Liaison Officers will receive a pre-exercise briefing.

PEMA Observers are not intended to be players and should excuse themselves from any active participation in the exercise. If an Observer is engaged in any way by one of the exercise players he/she should refer the player to the PEMA Liaison Officer.

112 4

Unclassified Radiological Emergency Preparedness Program (REP)

After Action, Report/Improvement Plan Three Mile Island Nuclear Generating Station PEMA Liaison Officers are players and are assigned specific responsibilities for the exercise.

Liaison Officers are instructed to call into the State Emergency Operations Center (SEOC) upon arrival at the exercise venue. They are required to confirm their arrival and provide to the SEOC Watch Officer phone numbers at which they can be reached during the exercise. Liaison Officers are allowed to interact in the exercise as a PEMA representativeand are sometimes required to provide injects to facilitate exercise play.

Parking and Directions Directions to each. venue area are available from the Lead Controller. Parking will be controlled according to existing policy at each individual location.

Restroom Facilities Restroom facilities will be available at each venue.

Exercise Identification Exercise participants will display their existing organizational identification badges.

Communications Plan Exercise Start, Suspension, and Termination Instructions The exercise. on April 12, 2011 is scheduled to run for 6.5 hours5.787037e-5 days <br />0.00139 hours <br />8.267196e-6 weeks <br />1.9025e-6 months <br /> or until the Lead Controller after consultation with FEMA and the Utility determine that the exercise objectives have been met.

The exercise is scheduled to end by 2200 hours0.0255 days <br />0.611 hours <br />0.00364 weeks <br />8.371e-4 months <br />. The Lead Controller will announce the exercise suspension or termination through the State Emergency Operations Center.

113

4 Unclassified Radiological Emergency Preparedness Program (REP)

After Action Report/Improvement Plan Three Mile Island Nuclear Generating Station Player Communication Players will use routine, in-place agency communication systems. Additional communication assets may be made available as the exercise progresses. All exercise communication over primary dispatch channels will cease immediately if a real world emergency is announced.

Communications concerning a real world emergency will be preceded by the phrase "This is not drill". In no instance will exercise communication interfere with real-world emergency communications. Exercise communication over these channels will recommence when authorized by the Exercise Director after he is advised by County 911 that it is safe to do so.

Each venue will coordinate its own internal communication networks and channels.

The primary means of communication among the SimCell, Controllers, and the venues will be telephone. A list of key telephone and fax numbers, and radio call signs will be available as a Communication Directory before the start of the exercise.

Player Briefing Controllers may be required to read specific scenario details to the participants to begin exercise play. They may also have technical handouts or other materials to give to players in order to better orient them to the exercise environment.

Public Affairs Joint Information Centers will be established at both the Utility Emergency Operations Facility and the State Emergency Operations Center. Actors will play the role of reporters and (simulated not publicly broadcast) "public briefings" will be given as they would for a real incident. The briefings will be available for viewing at the County EOCs.

Any participation by the actual media will be coordinated through the Exercise Director in conjunction with the PEMA Public Information Office.

114 4

Unclassified Radiological Emergency Preparedness Program (REP)

After Action Report/Improvement Plan Three Mile Island Nuclear Generating Station HAPTR 3: PLAYER UIDELINS Exercise Staff Exercise Director The Exercise Director has the overall responsibility for planning, coordinating, and overseeing all exercise functions. The Exercise Director for the 2011 Three Mile Island Plume Exercise is the RadiologicalEmergency Preparedness Regional Assistance Committee Chair. The Exercise Director has delegated the following responsibilities to other team: members:

The FEMA Region III Site Specialist for the Three Mile Island has authority to make determinations concerning evaluation issues and re-demonstrations, and, The PEMA HSEEP Coordinator has responsibility to organize and lead the Exercise Planning Team.

Trusted Agents Trusted agents are exercise planners and participants who are responsible for developing the Scenario and the Master Scenario Events List (MSEL). These documents are restricted and are not available to the rest of the Exercise Planning Team, Players, or other Participants. The trusted agents for the 2011 Three Mile Island Plume Exercise include the Exercise Director, Lead Controller, Bureau of Radiation Protection-(BRP) Representative, FEMA Emergency Management Program Specialist, and the Radiological Emergency Preparedness Regional Assistance Committee (RAC) Chair.

Lead Controller The Lead Controller also functions as a Trusted Agent. As such he is involved in developing the Master Scenario Events List and is privy to the scenario used at the Utility to generate exercise play. The Lead Controller is responsible for scheduling controllers at the "Out of Sequence" components of the exercise and the 2011 Three Mile Island Plume Exercise. The Lead Controller monitors exercise progress and coordinates decisions regarding deviations or significant changes to the scenario caused by unexpected developments during play. The Lead Controller monitors actions by individual Controllers and ensures they implement all designated and modified actions at the appropriate time. The Lead Controller will be the PEMA REP Training Program Manager is stationed in the State EOC during the Plume Exercise.

115

Unclassified Radiological Emergency Preparedness Program (REP)

After Action Report/Improvement Plan Three Mile Island Nuclear Generating Station Controllers At least one controller will be onsite with every facility and field team participating in the exercise, and at each out-of-sequence interview. The Controller at each location will coordinate any changes that impact the scenario or affect other areas of play through the Lead Controller The individual controllers issue exercise materials to players as required and monitor the exercise timeline. Controllers also provide injects to the players as described in the MSEL. The Trusted Agent from the Utility will act as the Controller at the Utility Site during the Plume exercise and the BRP Trusted Agent will act as Controller for the BRP Field Teams.

Lead Evaluator The Lead Evaluator is responsible for the overall evaluation of the 2011 Three Mile Island Plume Exercise. The Lead Evaluator monitors exercise progress and stays in contact with the Lead Controller regarding changes to the exercise during play. The Lead Evaluator monitors actions of individual Evaluators and ensures they are tracking progress of the players in accordance with the Overview of Play. The Lead Evaluator debriefs the evaluators after the exercise and oversees the entire evaluation and After Action process. The Lead Evaluator will be the FEMA Region III REP Site Specialist.

Evaluators Evaluators work under the direction of the Lead Evaluator, and as a team with Controllers.

Evaluators are Subject Matter Experts who record events that take place during the exercise and assess/submit documentation for review and inclusion in the After Action Report (AAR).

Evaluators should refrain from any direct interaction with the players during exercise play except with the facilitation of a Controller for clarification of issues or during scheduled interviews.

Player Instructions Before the Exercise

  • Review the appropriate emergency plans, procedures, and exercise support documents.
  • Arrive at the exercise location as instructed. Wear appropriate uniform/identification badge.
  • If you gain knowledge of the scenario before the exercise, notify a controller so that appropriate actions can be taken to ensure a valid evaluation.
  • Read your Player Information Handout, which includes information on exercise safety.
  • Please sign in.
  • Bureau of Radiation Protection Field Monitoring Teams will be briefed by the BRP Coordinator.

116 0

Unclassified Radiological Emergency Preparedness Program (REP)

After Action Report/Improvement Plan ThreeMile Island Nuclear Generating Station During the Exercise

  • Respond to the exercise events and information as if the emergency were real, unless otherwise directed by an exercise controller.
  • Controllers will only give you information-they are specifically directed to disseminate.

You are expected to obtain other necessary information through existing emergency information channels.

  • Do not engage in personal conversations with controllers, evaluators, observers, or media personnel while the exercise is in progress. If you are asked an exercise-related question, give a short, concise answer. If you are busy and cannot immediately respond, indicate so, but report back with an answer at the earliest time possible.

" If you do not understand the scope of the exercise or if you are uncertain about an organization's or agency's participation in an exercise, ask a controller.

" Parts of the scenario may seem implausible. Recognize that the exercise has objectives to satisfy and may require the incorporation of unrealistic aspects. Note that every effort has been made by the trusted agents, to balancerealism with safety and the creation of an effective learning and evaluation environment.

All exercise communication will begin and end with the phrase "This is a drill". This is a precaution taken so anyone overhearing the conversation will notmistake the exercise play for a real-world emergency.

  • When communicating with the SimCell, identify the organization, agency, office, and/or individual with which you want to speak.
  • Verbalize out loud when taking an action. This will ensure that evaluators are made aware of critical actions as they occur.

Maintain a log of your activities. Many times, this log may include documentaition of activities missed by a controller or evaluator.

Following the Exercise

  • At the end of the exercise at your facility, participate in a debriefing with the controllers and evaluators.
  • Provide all rosters, sign in sheets, logs, messages, notes or materials generated from the exercise to your controller or evaluator for review and inclusion in the AAR.
  • Bureau of Radiation Protection Field Monitoring Teams will be debriefed immediately following the exercise by the BRP Coordinator.

117

Unclassified Radiological Emergency Preparedness Program (REP)

After Action Report/Improvement Plan Three Mile Island Nuclear Generating Station Simulation Guidelines Because the 2011 Three Mile Island Plume Exercise is of limited duration and scope, the physical description of what would fully occur at the incident sites and surrounding areas will be relayed to the Players by Simulators or Controllers.

If a real emergency occurs during the exercise, the exercise at your respective venue may be suspended or terminated at the discretion,of the controller(s) at each venue. If a real emergency occurs, provide assistance up to the level of your training, call 911 and use the phrase "This is not a drill" and ask for the appropriate assistance, and notify the nearest Controller and Evaluator.

118 4

Unclassified Radiological Emergency Preparedness Program (REP)

After Action Report/Improvement Plan Three Mile Island Nuclear Generating Station CHAPTER 4: EVALUATION AND POST-EXERCISE ACTIVITIES Exercise Documentation The goal of the 2011 Three Mile Island Plume Exercise is to comprehensively exercise and evaluate the OROs' plans andcapabilities as they pertain toa potential nuclear power plant incident. After the exercise, data collected by 'Controllers, Evaluators, and Players will be used to identify strengths and areas for improvement in the context of the exercise design objectives.

Exercise Evaluation Guides DHS has developed Exercise Evaluation Guides (EEGs) that identify expected activities for evaluation, provide consistency across exercises, and link individual tasks to disciplines and expected outcomes.

The EEGs selected by the Exercise Planning Team are contained in the evaluator materials packet along with the Evaluator Handbook. These EEGs have been selected because the activities they describe can be expected to be observed during the exercise and will guide evaluation to match the exercise design objectives. Supplemental REP evaluation material designed for the exercise may also be used.

DEBRIEFING Immediately following the completion of exercise play, Controllers will facilitate a debriefing with Players from their assigned location. The debriefing is an opportunity for Players to voice their opinions on the exercise and their own performance. At this time, Evaluators can also seek clarification on certain actions and what prompted Players to take them. The debriefing should not last more than 30 minutes. Evaluators should take notes during the debriefing and include these observations in their analysis.

Exercise Evaluation Hotwash Controllers, Evaluators, and selected exercise participants will attenda facilitated Controller and Evaluator Hotwash on April 14, 2011 at 1500 hours0.0174 days <br />0.417 hours <br />0.00248 weeks <br />5.7075e-4 months <br /> at the Hilton Garden Inn at 3943 Tecport Drive, Harrisburg, Pa. 17111. During the Hotwash these individuals will discuss their observations of the exercise in an open environment to clarify actions taken during the exercise.

Participants and Public/Media Briefings The Participants Briefing will be conducted on April 15, 2011 at 1000 hours0.0116 days <br />0.278 hours <br />0.00165 weeks <br />3.805e-4 months <br /> followed immediately by the Public/Media Briefing at 1100 hours0.0127 days <br />0.306 hours <br />0.00182 weeks <br />4.1855e-4 months <br />. Both briefings will be held at the Hilton Garden Inn at 3943 Tecport Drive, Harrisburg, Pa. 17111.

119

Unclassified Radiological Emergency Preparedness Program (REP)

After Action Report/Improvement Plan Three Mile Island Nuclear Generating Station After Action Report The AAR is the culmination of the exercise. It is a written report outlining the strengths and areas for im.prvement identified during tbe exercise. The AAR will include, the timeline, executive sumnlmary, scenario description, missiorr outcomes, and capability analysis. The AAR will be drafted by a core group of individuals from the exercise planning team.

After Action Conference and Improvement Plan The improvement process represents the comprehensive, continuing preparedness effort of which the 2011 Three Mile Island Plume Exercise is a part. The lessons learned and recommendations from the AAR will be incorporated into the Improvement Plan (IP).

After Action Conference The After Action Conference (AAC), scheduled for May 20, 2011 at 1000 hours0.0116 days <br />0.278 hours <br />0.00165 weeks <br />3.805e-4 months <br />, is a forum for jurisdiction officials to hear the results of the evaluation analysis, validate the findings and recommendations in the draft AAR, and begin development of the IP. The After Action Conference will be conducted via a conference call.

Improvement Plan The IP identifies how recommendations will be addressed, including what actions will be taken, who is responsible, and the timeline for completion. It is created by key stakeholders from the 2011 Three Mile Island Plume Exercise participating agency officials during the AAC scheduled for May 20, 2011.

120 a

Unclassified Radiological Emergency Preparedness Program (REP)

Three Mile Island Nuclear Generating Station After Action Report/Improvement Plan APPENDIX A: EXERCISE SCHEDULE Table A.1 [TMI] Schedule 4/12/2011 0900- 1100 Schools and Montour County 1600 - 2230 Plume Exercise 4/13/2011 1000- 1200 State Police 1900-2100 ReceptionCenters, Mass Care, EW Mon/becoh 4/14/2011 1500

___.___________Hotwash 4/15/2011 1000 Participants Briefiig 1100 Public/Media Briefing 121

a Unclassified Radiological Emergency Preparedness Program (REP)

Three Mile Island Nuclear Generating Station After Action Report/Improvement Plan This page is intentionally left blank.

41 0

122 0

Unclassified Radiological Emergency Preparedness Program (REP)

Three Mile Island Nuclear Generating Station After Action Report/Improvement Plan APPENDIX E: EXTENT OF PLAY THREE MILE ISLAND NUCLEAR GENERATING STATION 2011 RADIOLOGICAL EMERGENCY PREPAREDNESS EXERCISE 123

a Unclassified Radiological Emergency Preparedness Program (REP)

Three Mile Island Nuclear Generating Station After Action Report/Improvement Plan a

Page Intentionally Left Blank 124 a

Unclassified Radiological Emergency Preparedness Program (REP)

After Action Report/Improvement Plan Three Mile Island Nuclear Generating Station Table of Contents Page Method of Operation 126

1. Three Mile Island Nuclear Generating Station 126
2. Bureau of Radiation Protection 126
3. PEMA Headquarters/State EOC 126
4. PEMA Area Offices 127
5. Counties Participating 127
6. PEMA Liaison Officers 127
7. Controllers 127
8. PEMA Observers 128
9. DHS (FEMA/REP) Evaluators 128
10. Demonstration Windows 128
11. Stand-down 129
12. General Concepts..

130

13. Re-demonstrations 130 Extent of Play Agreement 131 Evaluation Area 1 131 Evaluation Area 2 137 Evaluation Area 3 143 Evaluation Area 4 155 Evaluation Area 5 159 Evaluation Area 6 166 American Red Cross Chapter Listing 175 Attachment A - Demonstration Tables 176 School Districts 176 County Emergency Operation Centers 178 Municipal Emergency Operations Centers 179 Route Alerting 180 Traffic/Access Control Points 180 Reception Centers 181 Monitoring/Decontamination Centers 182 Mass Care & Monitoring / Decontamination Centers 183 Emergency Worker Monitoring / Decontamination Stations 184 Post Plume Exercise 184 Attachment B - Listing of Prior Issues 184 125

Unclassified Radiological Emergency Preparedness Program (REP)

After Action Report/Improvement Plan Three Mile Island Nuclear Generating Station METHOD OF OPERATION

1.

Three Mile Island Nuclear Generating Station (TMI)

The facility normally uses off-watch section personnel to participate in the exercise. The plant's simulated events, radiation readings, and emergency classifications will trigger offsite exercise actions. A pre-approved exercise scenario will be used. TMI will notify the State EOC and risk counties of emergency classifications.

2.

Bureau of Radiation Protection (BRP)

Personnel from the Pennsylvania Bureau of Radiation Protection (BRP) will be present and participate in the following aspects of the exercise:

Plume Exercise - State EOC Plume Exercise - Exelon EOF Field Sampling Teams & Command Vehicle - (Not Evaluated)

BRP personnel will be evaluated as participants with the exception of the Field Sampling Team and Command Vehicle.

3.

PEMA Operations at State EOC!PEMA Headquarters This "Method of Operation" Document includes activities for the Full-Scale Plume Exercise (April 12, 2011), and the "Out of Sequence" Activities (April 12 & April 13, 2011).

A. Plume Exercise - April 12, 2011 PEMA Bureau of Operations and Training staff, augmented by designated PEMA personnel from the Fire Commissioner's Office, the Bureau of Administration, Technical Services, Plans, plus Emergency Preparedness Liaison Officers (EPLOs) with accompanying response team members from designated state departments/agencies, including representatives from the USDA State Emergency Board will comprise initial operations at the State Emergency Operations Center (EOC). The State EOC will be evaluated during this exercise.

B. Plume Exercise - "Out of Sequence" Activities - April 12, 2011.

PEMA Bureau of Operations and Training staff, augmented by designated PEMA personnel will disseminate exercise related messages to the participating Counties for dissemination to the participating School Districts during the morning of April 12, 2011. The State Emergency Operations Center (EOC) and County EOCs will NOT be evaluated during the "Out of Sequence" component. PEMA personnel will serve as "observers" at the identified School Districts.

126 0

Unclassified Radiological Emergency Preparedness Program (REP)

After Action Report/Improvement Plan Three Mile Island Nuclear Generating Station C. "Out of Sequence" Activities - April 13, 2011.

PEMA personnel will serve as "Observers" at the various field exercise locations during the evening "Out-of-Sequence", component April 13, 2011. An exercise coordinator will remain in the State EOC. The State Emergency Operations Center (EOC) and Counties, will NOT be evaluated during the evening "Out of Sequence" component.

4.

PEMA Area Office Operations The PEMA Area Offices (Hamburg -Eastern Area and Harrisburg - Central Area) will not be activated nor evaluated during this exercise. Selected staff of the Area Offices will serve as Liaison Officers to Risk and Support Counties as assigned. Liaison Officers are exercise participants.

5.

Counties Designated to Participate, A. Plume Phase Exercise (April 12, 2011):.

The five risk counties (Cumberland, Dauphin, Lancaster, Lebanon, and York), in coordination with PEMA, will demonstrate the capability to mobilize appropriate staff, activate their respective Emergency Operations Centers and implement emergency response operations to include sheltering and/or evacuation. County government will provide direction and, coordination to risk municipalities. The three support counties (Adams, Franklin, and Schuylkill) will participate in their assigned support roles. Actual sheltering or evacuation of the general public will be simulated.

6.

PEMA Liaison Officers Liaison officers will be present at the participating risk/support county EOCs, the TMI Emergency Operations Facility (EOF) and the TMI Joint Information Center (JIC) to provide assistance, guidance, and support. These liaison officers will participate as players in the plume phase exercise on April 12, 2010.

7.

Controllers A lead controller will be present in the state EOC for the plume exercise and the out of sequence school exercise. Controllers will be supplied by the utility and will be present at the emergency worker monitoring/decontaminating stations and the mass care monitoring/

decontamination centers (April 13, 2010). Controllers are not players. Controllers will provide pre-approved injects and information to the players, as appropriate, regarding radiological readings during the monitoring of personnel.

127

Unclassified Radiological Emergency Preparedness Program (REP)

After Action Report/Improvement Plan Three Mile Island Nuclear Generating Station Live radioactive sources will not be used. Exception: individuals tasked with the setup of portal monitoring equipment will use a standard 1 micro curie Cesium 137 check source for the purpose of conducting an operational test. Additionally, appropriate test sources will be available and used to verify the operation of the monitoring /survey instruments per manufacturer's recommendations.

8.

PEMA Observers PEMA staff, qualified county emergency management personnel, and/or nuclear power plant personnel will be assigned, if required, to key locations for the purpose of observing, noting response actions and conditions, and recording observations for future use.

Observers will not take an active part in the proceedings, but will interact with staff members to the extent necessary to fulfill their observer responsibilities. Coaching of players by observers is not permitted except to provide training to participants awaiting a re-demonstration. (Refer to paragraph 13)

9.

Department of Homeland Security (DHS) Evaluators A. Plume Exercise:

Out of Sequence Period (April 12, 2011): Federal evaluators will be present at the identified "out-of-sequence" demonstration sites per Attachment A,Section I.A. 1 These include the identified Public School Districts.

Plume Phase Exercise (April 12, 2011): Federal evaluators will be present at the SEOC and identified risk and support county EOC's to evaluate player response to the actual and simulated events in the exercise scenario. Additionally, one-third of the risk municipalities will be federally evaluated. As required, a "floating-evaluator" will be made available for the purpose of evaluating any ORO locations not scheduled to have a federal evaluator, but having a prior issue (Attachment A,Section I.A.2 and I.A.3).

Out of Sequence Period (April 13, 2011): Federal evaluators will be present at identified Reception Centers, Emergency Worker Monitoring and Decontamination Stations, Mass Care Shelters, and Monitoring and Decontamination Centers, as identified in Attachment A,Section I.B. 1, I.B.2 and I.B.3.

10.

Demonstration Windows In order to provide for more effective demonstrations, as well as to permit the release of volunteers from exercise play at a reasonable hour, periods of time (Demonstration Windows) have been designated during which specified actions will be accomplished /

demonstrated.

128 0

Unclassified Radiological Emergency Preparedness Program (REP)

After Action Report/Improvement Plan Three Mile Island Nuclear Generating Station The "demonstration windows" for this exercise are:

A. Plume Phase Exercise The out-of-sequence MS-I hospital demonstration was federally evaluated at Hanover General Hospital, York County, on June 5th, 2009.

The out-of-sequence exercise window for school demonstrations will be from 9:00 -

11:00 a.m. on April 12, 2011.

The out-of-sequence demonstration of reception centers, mass care centers, monitoring/decontamination centers, and emergency worker stations will be conducted from 7:00 - 9:30 p.m. on April 13, 2011 Locations are specified within Attachment A, Section B.

The out-of-sequence interview of Pennsylvania State Police traffic control/access control points will be from 10:00 a.m. - 12:00 noon on April 13, 2011.

County and municipal EOC operations will be conducted on the evening of April 12, 2011. (Please refer to the Extent of Play Attachment A I.A.2 and I.A.3)

All demonstrations will commence promptly and, barring any complications, not continue beyond the time of the designated demonstration window (Demonstration Tables, Attachment A).

B. Post Plume Exercise No post-plume phase exercise is scheduled during this evaluation.

11.

Stand-down All jurisdictions will request approval on a jurisdiction by jurisdiction basis prior to stand-down.

a. Upon completion of all requirements and confirming with the federal evaluator that all evaluation areas have been demonstrated and/or completed, the risk municipality EOCs may request approval from their county EOC to "stand-down".
b. Support counties may likewise request approval from the State EOC to terminate the exercise upon completion of all evaluated objectives.
c. The risk county EOCs will remain operational until the exercise is officially terminated by the State or by approval of the federal evaluator. The State EOC will issue an Exercise Termination Message.

129

Unclassified Radiological Emergency Preparedness Program (REP)

After Action Report/Improvement Plan Three Mile Island Nuclear Generating Station

12.

General Concepts An emergency plan is drafted to address the generally expected conditions of an emergency. Not everything in the emergency plan may be applicable for a given scenario.

The main purpose of an emergency plan is to assemble sufficient expertise and officials so as to properly react to the events as they occur. The responders should not be so tied to a plan that they cannot take actions that are more protective of the public. Furthermore, if, by following the plan there is a failure to protect the public health and safety, it should be noted so that the plan can be modified and the appropriate negative assessment corrected.

13.

Re-demonstrations Any activity that is not satisfactorily demonstrated may be re-demonstrated by the participants during the exercise, provided it does not negatively interfere with the exercise.

Refresher training may be provided bythe players, observers, and/or controllers.

Evaluators are not permitted to provide refresher training. Re-demonstrations will be negotiated between the players, obserVers, controllers, and evaluators. PEMA may advise the RAC Chair prior to initiating any re-demonstrations. It is permissible to extend the demonstration window, within reason, to accommodate the re-demonstration. Activities corrected from a re-demonstration will be so noted.

130 0

Unclassified Radiological Emergency Preparedness Program (REP)

After Action Report/Improvement Plan Three Mile Island Nuclear Generating Station THREE MILE ISLAND NUCLEAR GENERATING STATION 2011 RADIOLOGICAL EMERGENCY PREPAREDNESS EXERCISE EXTENT OF PLAY AGREEMENT EVALUATION AREA 1 Emergency Operations Management Sub-element L.a - Mobilization INTENT This sub-element derives from NUREG-0654, which provides that Offsite Response Organizations (ORO) should have the capability to alert, notify, and mobilize emergency personnel and to activate and staff emergency facilities.

Criterion 1.a.1: OROs use effective procedures to alert, notify, and mobilize emergency personnel and activate facilities in a timely manner. (NUREG-0654, A.4; D.3, 4; E.1, 2; H.4)

EXTENT OF PLAY Responsible OROs should demonstrate the capability to receive notification of an emergency situation from the licensee, verify the notification, and contact, alert, and mobilize key emergency personnel in a timely manner. Responsible OROs should demonstrate the activation of facilities for immediate use by mobilized personnel when they arrive to begin emergency operations. Activation of facilities should be completed in accordance with the plan and/or procedures. Pre-positioning of emergency personnel is appropriate, in accordance with the extent of play agreement, at those facilities located beyond a normal commuting distance from the individual's duty location or residence. Further, pre-positioning of staff for out-of-sequence demonstrations is appropriate in accordance with the extent of play agreement.

All activities must be based on the ORO's plans and procedures and completed as they would be in an actual emergency, unless noted above or otherwise indicated in the extent of play agreement.

131

Unclassified Radiological Emergency Preparedness Program (REP)

After Action Report/Improvement Plan Three Mile Island Nuclear Generating Station PEMA Negotiated Extent of Play:

Pre-positioning of state emergency personnel (Liaison Officers) at the Emergency Operations Facility (EOF), the Joint Information Center (JIC) and risk and support counties is appropriate due to the commuting distance from the individual's duty location or residence. Risk counties/municipalities and support counties will conduct call-outs to demonstrate the mobilization of key personnel. The utility JIC will be evaluated for this exercise.

" Actual calls (orpager notifications) will be made to the municipal EOCpersonnel for the plume phase exercise, April 12, 2011, per plans andprocedures.

  • In all instances, the demonstration of a shift change is NOT required. Twenty-four hour staffing will be demonstrated by means of a roster or staffing chart.
  • All out-of-sequence players and equipment will be pre-positioned (school district personnel, Pennsylvania State Police A CP, reception centers, Emergency Worker Monitoring and Decontamination Stations and Monitoring and Decontamination Centers).

" Individuals working in state facilities and county EOCs may be pre-positionedfor the plume phase.

Sub-element 1.b - Facilities INTENT This sub-element derives from NUREG-0654, which provides that Offsite Response Organizations (ORO) have facilities to support the emergency response.

Criterion l.b.l: Facilities are sufficient to support the emergency response.

(NUREG-0654, H.3)

EXTENT OF PLAY Facilities will only be specifically evaluated for this criterion if they are new or have substantial changes in structure or mission. Responsible OROs should demonstrate the availability of facilities that support the accomplishment of emergency operations. Some of the areas to be considered are: adequate space, furnishings, lighting, restrooms, ventilation, backup power and/or alternate facility (if required to support operations.)

Facilities must be set up based on the ORO's plans and procedures and demonstrated as they would be used in an actual emergency, unless noted above or otherwise indicated in the extent of play agreement.

132

Unclassified Radiological Emergency Preparedness Program (REP)

Three Mile Island Nuclear Generating Station After Action Report/Improvement Plan PEMA Negotiated Extent of Play: None. Note that Schuylkill County recently completed EOC renovations.

Sub-element i.c - Direction and Control INTENT This sub-element derives from NUREG-0654, which provides that Offsite Response..

Organizations (ORO) have the capability to control their overall response to an emergency.

Criterion 1.c.l: Key personnel with leadership roles for the ORO provide direction and control to that part of the overall response effort for which they are responsible.

(NUREG-0654, A.l.d; A.2.a, b)

EXTENT OF PLAY Leadership personnel should demonstrate the ability to carry out essential functions of the response effort, for example: keeping the staff informed through periodic briefings and/or other means, coordinating with other appropriate OROs, and ensuring completion of requirements and requests.

All activities associated with direction and control must be performed based on the ORO's plans and procedures and completed as they would be in an actual emergency, unless otherwise noted above or indicated in the extent of play agreement.

PEMA Negotiated Extent of Play: None Sub-element 1.d - Communications Equipment INTENT This sub-element derives from NUREG-0654, which provides that Offsite Response Organizations (ORO) should establish reliable primary and backup communication systems to ensure communications with key emergency personnel at locations such as the following:,

appropriate contiguous governments within the emergency planning zone (EPZ), Federal emergency response organizations, the licensee and its facilities, emergency operations centers (EOC), and field teams.

133

Unclassified Radiological Emergency Preparedness Program (REP)

After Action Report/Improvement Plan Three Mile Island Nuclear Generating Station Criterion 1.d.l: At least two communication systems are available, at least one operates properly, and communication links are established and maintained with appropriate locations. Communications capabilities are managed in support of emergency operations. (NUREG-0654, F.1, 2)

EXTENT OF PLAY OROs will demonstrate that a primary and at least one backup system awe fully functional at the beginning of an exercise. If a communications system or systems are not functional, but exercise performance is not affected, no exercise issue will be assessed. Communications equipment and procedures for facilities and field units should be used as needed for the transmission and receipt of exercise messages. All facilities and field teams should have the capability to access at least one communication system that is independent of the commercial telephone system. Responsible OROs should demonstrate the capability to manage the communication systems and ensure that all message traffic is handled without delays that might disrupt the conduct of emergency operations.

OROs should ensure that a coordinated communication link for fixedand mobile medical support facilities exists. The specific communications capabilities of OROs should be commensurate with that specified in the response plan and/or procedures. Exercise scenarios could require the failure of a communications system and the use of an alternate system, as negotiated in the extent of play agreement.

All activities associated with the management of communications capabilities must be demonstrated based on the ORO's plans and procedures and completed as they would be in an actual emergency, unless otherwise noted above or in the extent of play agreement.

PEMA Negotiated Extent of Play:

The plant will communicate to the risk counties and State EOC utilizing the Dedicated Automatic Ring Down Telephone System (ARD) (Primary) and the commercial telephone system (Secondary). Risk and Support Counties will intercommunicate with the State EOC via the commercial telephone system (Primary), SEVAN (Secondary) and other systems. In the event that the plant is unable to contact the state EOC via the Dedicated Automatic Ring Down Telephone, the Power Plant will contact the State EOC via the commercial telephone system. If the plant cannot contact the State EOC, the Power Plant will contact the Dauphin County EOC and Dauphin County EOC fulfill the role ofprimary contact until such time as communications with the State EOC can be made.

Risk counties will communicate with their risk municipalities via public safety radio frequencies (EAM Radio), commercial telephone, fax, or Amateur Radio Communications (ARES/RA CES) or other available means.

134 0

Unclassified Radiological Emergency Preparedness Program (REP)

After Action Report/Improvement Plan Three Mile Island Nuclear Generating Station Sub-element i.e - Equipment and Supplies to Support Operations INTENT This sub-element derives from NUREG-0654, which provides that Offsite Response Organizations (ORO) have emergency equipment and supplies adequate to support the emergency response.

Criterion 1.e.1: Equipment, maps, displays, dosimetry, potassium iodide (KI), and other supplies are sufficient to support emergency operations. (NUREG-0654, H.7, 10; J.10.a, b, e, J.11; K.3.a)

EXTENT OF PLAY Equipment within the facility (facilities) should be s*ufficient and consistent with the role assigned to that facility in the ORO's 'plans: and/or procedures, in support of emergency operations. Use of maps and displays is encouraged.

All instruments, including air sampling flow meters (field teams only), should be inspected, inventoried, and operationally checked before each use, Instruments should be calibrated in accordance with the manufacturer's recommendations. Unmodified CDV-700 series instruments and other instruments, without a manufacturer's recommendation should be calibrated annually.

Modified CDV-700 instruments should be calibrated in accordance with the recommendation of the modification manufacturer. A label indicating such calibration should be on each instrument, or the calibration frequency may be verified by other means. Additionally, instruments being used to measure activity should have a range of reading sticker affixed to the side of the instrument. The above considerations should be included in 4.a. 1 for field team equipment; 4.c. 1 for radiological laboratory equipment (does not apply to analytical equipment; reception center and emergency worker facilities' equipment under 6.a. 1; and ambulance and medical facilities' equipment under 6.d. 1.

Sufficient quantities of appropriate direct-reading and permanent record dosimeters and dosimeter chargers should be available for issuance to all categories of emergency workers that could be deployed from that facility. Appropriate direct-reading dosimetry should allow individual(s) to read the administrative reporting limits and maximum exposure limits contained in the ORO's plans and procedures.

135

Unclassified Radiological Emergency Preparedness Program (REP)

After Action Report/Improvemcnt Plan Three Mile Island Nuclear Generating Station Dosimetry (Direct Reading Dosimeters) should be inspected for electrical leakage at least annually and replaced; if necessary. CDV-138s, due to their documented history of electrical leakage problems, should be inspected for electrical leakage at least quarterly and replaced if necessary. This leakage testing will be verified during the exercise, through documentation submitted in the Annual Letter of Certification, and/or through a staff assistance visit.

Responsible OROs should demonstrate the capability to maintain inventories of KI sufficient for use by emergency workers, as indicated on rosters; institutionalized individuals, as indicated in capacity lists for facilities; and, where stipulated by the plan and/or procedures, members of the general public (including transients) within the plume pathway EPZ.

Quantities of dosimetry and KI available and storage locations(s) will be confirmed by physical inspection at storage location(s) or through documentation of current inventory submitted during the exercise, provided in the Annual Letter of Certification submission, and/or verified during a Staff Assistance Visit. Available supplies of KI should be within the expiration date indicated on KI bottles or blister packs. As an alternative, the ORO may produce a letter from a certified private or State laboratory indicating that the KI supply remains potent, in accordance with U.S.

Pharmacopoeia standards.

At locations where traffic and access control personnel are deployed, appropriate equipment (for example, vehicles, barriers, traffic cones and signs, etc.) should be available or their availability described.

All actiVities must be based on the ORO's plans and procedures and completed, as they would be in an actual emergency, unless noted above or otherwise indicated in the extent of play agreement.

PEMA Negotiated Extent of Play:

Radiological Survey Instruments are calibrated per manufactures recommendations. Support counties do. not have DRDs, or KI, but those responsible for reception centers and / or monitoring and decontamination centers will have PRDs. Neither CDV-700 nor CDV-138 instruments are in use in the area.

Evaluation of KI quantities will be verified using inventory sheets. KI will not be removed from storage locations and boxes /packages will not be opened, however, lot numbers and expiration dates should be visible for inspection. KI questions will be addressed through interviews.

Annual Direct Reading Dosimeter leakage testing verification will be available to the evaluator.

136 6

Unclassified Radiological Emergency'Preparedness Program (REP)

After Action Report/Improvernent Plan Three Mile Island Nuclear Generating Station Reception Centers shall be evaluated on their ability to use maps or other documentation to direct evacuating persons to the correct Monitoring/Decontamination Centers and/or Mass Care Centers (as Applicable).

EVALUATION AREA 2 Protective Action Decision-Making Sub-element 2.a - Emergency Worker Exposure Control INTENT This sub-element derives from NUREG-0654, which provides that Offsite Response Organizations (ORO) have the capability to assess and control the radiation exposure received by emergency workers and have a decision chain in place, as specified in the ORO's plans and procedures, to authorize emergency worker.expossure limits to be exceeded for specific missions.

Radiation exposure limits for emergency workers are the'recommended accumulated dose limits or exposure rates emergency Workers may belpermitted to incur during an emergency. These limits include any pre-established administrative reporting limits (that take into consideration Total Effective Dose Equivalent or organ-specific limits) identified in the ORO's plans and procedures.

Criterion 2.a.l: OROs use a decision-making process, considering relevant factors and appropriate coordination, to ensure that an exposure control system, including the use of KI, is in place for emergency workers including provisions to authorize radiation exposure in excess of administrative limits or protective action guides.

(NUREG-0654, K.4, J.1O. e, f)

EXTENT OF PLAY OROs authorized to send emergency workers into the plume exposure pathway EPZ should demonstrate a capability to meet the criterion based on their emergency plans and procedures.

Responsible OROs should demonstrate the capability to make decisions concerning the authorization of exposure levels in excess of pre-authorized levels and to the number of emergency workers receiving radiation dose abovepre-authorized levels. As appropriate, OROs should demonstrate the capability to make decisions on the distribution and administration of KI as a protective measure, based on the ORO's plan and/or procedures or projected thyroid dose compared with the established Protective Action Guides (PAGs) for KI administration.

137

Unclassified Radiological Emergency Preparedness Program (REP)

After Action Report/Improvement Plan Three Mile Island Nuclear Generating Station All activities must be based on the ORO's plans and procedures and completed, as they would be in an actual emergency, unless noted above or otherwise indicated in the extent of play agreement.

PEMA Negotiated Extent of Play:

Radiological briefings (verbal and/or video) will be provided to address exposure limits, procedures to replace those personnel approaching exposure limits, and how permission to exceed limits is obtainedfrom the municipality and county. Emergency workers will also be briefed on when to take KI and on whose authority. Distribution of actual KI to emergency workers will be simulated.

The completion of a maximum of 6 "Dosimetry-K! Report Form" will be demonstrated per applicable action location.

Sub-element 2.b. - Radiological Assessment and Protective Action Recommendations and Decisions for the Plume Phase of the Emergency INTENT This sub-element derives from NUREG-0654, which provides that Offsite Response Organizations (ORO) have the capability to use all available data to independently project integrated dose and compare the estimated dose savings with the protective action guides. OROs have the capability to choose, among a range of protective actions, those most appropriate in a given emergency situation. OROs base these choices on PAGs from the ORO's plans and procedures or EPA 400-R-92-001 and other criteria, such as, plant conditions, licensee protective action recommendations, coordination of protective action decisions with other political jurisdictions (for example, other affected OROs), availability of appropriate in-place shelter, weather conditions, and situations that create higher than normal risk from evacuation.

Criterion 2.b.l: Appropriate protective action recommendations are based on available information on plant conditions, field monitoring data, and licensee and ORO dose projections, as well as knowledge of onsite and offsite environmental conditions. (NUREG-0654, 1.8, 10 and Supplement 3) 138

Unclassified Radiological Emergency Preparedness Program (REP)

After Action Report/Improvement Plan Three Mile Island Nuclear Generating Station EXTENT OF PLAY During the initial stage of the emergency response, following notification of plant conditions that may warrant offsite protective actions, the ORO should demonstrate the capability to use appropriate means, described in the plan and/or procedures, to develop protective action recommendations (PARs) for decision-makers based on available information and recommendations from the licensee and field monitoring data, if available.

When the licensee provides release and meteorological data, the ORO also considers these data.

The ORO should demonstrate a reliable capability to independently validate dose projections. The types of calculations to be demonstrated depend on the data available and the need for assessments to support the PARs appropriate to the scenario. In all cases, calculation of projected dose should be demonstrated. Projected doses should be related to quantities and units of the PAGs to which they will be compared. PARs should be promptly transmitted to decision-makers in a prearranged format.

Differences greater than a factor of 10 between projected doses by the licensee and the ORO should be discussed with the licensee with respect to the input data and assumptions used, the use of different models, or other possible reasons. Resolution of these differences should be incorporated into the PAR if timely and appropriate. The ORO should demonstrate the capability to use any additional data to refine projected doses and exposure rates and revise the associated PARS.

All activities must be based on the ORO's plans and procedures and completed as they would be in an actual emergency, unless noted above or otherwise indicated in the extent of play agreement.

PEMA Negotiated Extent of Play: None.

Criterion 2.b.2: A decision-making process involving consideration of appropriate factors and necessary coordination is used to make protective action decisions (PAD) for the general public (including the recommendation for the use of KI, if ORO policy).

(NUREG-0654, J.9, 10.f, m) 139

Unclassified Radiological Emergency Preparedness Program (REP)

After Action Report/Improvemcnt Plan Three Mile Island Nuclear Generating Station EXTENT OF PLAY Offsite Response Organizations (ORO) should have the capability to make both initial and subsequent PADs. They should demonstrate the capability to make initial PADs in a timely manner appropriate to the situation, based on notification from the licensee, assessment of plant status and releases, and PARs from the utility and ORO staff.

The dose assessment personnel may provide additional PARs based on the subsequent dose projections, field monitoring data, or information on plant conditions. The decision-makers should demonstrate the capability to change protective actions as appropriate based on these projections.

If the ORO has determined that KI will be used as a protective measure for the general public under off-site plans, then the ORO should demonstrate the capability to make decisions on the distribution and administration of KI as a protective measure for the general public to supplement shelter and evacuation. This decision should be based on the ORO's plan and/or procedures or projected thyroid dose compared with the established PAG for KI administration. The KI decision-making process should involve close coordination with appropriate assessment and decision-making staff.

If more than one ORO is involved in decision-making, OROS should communicate and coordinate PADs with affected OROs. OROs should demonstrate the capability to communicate the contents of decisions to the affected jurisdictions.

All decision-making activities by ORO personnel must be performed based on the ORO's plans and procedures and completed as they would be in an actual emergency, unless noted above or otherwise indicated in the extent-of play agreement.

PEMA Negotiated Extent of Play: None Sub-element 2.c - Protective Action Decisions Consideration for the Protection of Special Populations 140

Unclassified Radiological Emergency Preparedness Program (REP)

After Action Report/Improvement Plan Three Mile Island Nuclear Generating Station INTENT This sub-element derives from NUREG-0654, which provides that Offsite Response Organizations (ORO) should have the capability to determine prote.ctive action recommendations, including evacuation, sheltering and use of potassium iodide (KI), if applicable, for special population groups (for example, hospitals, nursing homes, correctional facilities, schools, licensed day care centers, mobility impaired individuals, and transportation dependent individuals). Focus is on those special population groups that are (or potentially will be) affected by a radiological release from a nuclear power plant.

Criterion 2.c.1: Protective action decisions-are made, as appropriate, for special population groups. (NUREG-0654, J.9, J.10.d, e)

EXTENT OF PLAY Usually, it is appropriate to implement eyacuation in areas where doses are projected to exceed the lower end of the range of PAGs, except for situations where there is a high-risk environment or where high-risk groups (e.g., the immobile or infirm) are involved. In these cases, examples of factors that should be considered are weather conditions, shelter availability, availability of transportation assets, risk of evacuation vs. risk from the, avoided dose, and precautionary school evacuations. In situations where. an institutionalized population cannot be evacuated, the administration of KI should be considered by the OROs.

Applicable OROs should demonstrate the, capability to alert and notify all public school systems/districts of emergency conditions, that are expected to or may necessitate protective actions for students. Contacts with public school systems/districts must be actual.

In accordance with plans and/or procedures, OROs and/or officials of public school systems/districts should demonstrate the capability to make prompt decisions on protective actions for students. Officials should demonstrate that the decision making process for protective.

actions considers (that is, either accepts automatically or gives heavy weight to) protective action recommendations made by ORO personnel, the ECL at which these recommendations are received, preplanned strategies for protective actions for that ECL, and the location of students at the time (for example, whether the students are still at home, en route to the school, or at the school).

141

Unclassified Radiological Emergency Preparedness Program (REP)

After Action ReportlImprovement Plan Three Mile Island Nuclear Generating Station All decision-making activities associated with protective actions, including consideration of available resources, for special population groups must be based on the ORO'splans and procedures and completed; as they would be in an actual emergency, unless noted above or otherwise indicated in the extent of play agreement.

PEMA Negotiated Extent of Play: None Sub-element 2.d. - Radiological Assessment and Decision-Making for the Ingestion Exposure Pathway INTENT This sub-element is derived from NUREG-0654, which provides that Offsite Response Organizations (ORO) have the means to assess the radiological consequences for the ingestion exposure pathway, relate them to the appropriate PAGs, and make timely, appropriate protective action' decisions to mitigate exposure from the ingestion pathway.

During an accident at a nuclear power plant, a release of radioactive material may contaminate water supplies and agricultural products in the surrounding areas. Any such contamination would likely occur during the plume phase of the accident and, depending on the nature of the release, could impact the ingestion pathway for weeks or years.

PEMA Negotiated Extent of Play:

This sub-element will not be demonstrated or evaluated during this exercise.

Sub-element 2.e. - Radiological Assessment and Decision-Making Concerning Relocation, Re-entry, and Return Relocation: OROs should demonstrate the capability to estimate integrated dose in contaminated areas and to compare these estimates with PAGs, apply decision criteria for relocation of those individuals in the general public who have not been evacuated but where projected doses are in excess of relocation PAGs, and control access to evacuated and restricted areas. Decisions are made for relocating members of the evacuated public who lived in areas that now have residual radiation levels in excess of the PAGs.

Determination of areas to be restricted should be based on factors such as the mix of radio nuclides in deposited materials, calculated exposure rates vs. the PAGs, and field samples of vegetation and soil analyses.

142 0

Unclassified Radiological Emergency Preparedness Program (REP)

After Action Report/Improvement Plan Three Mile Island Nuclear Generating Station Re-entry: Decisions should be made regarding the location of control points and policies regarding access and exposure control for emergency workers and members of the general public who need to temporarily enter the evacuated area to perform specific tasks or missions.

Examples of control procedures are: the assignment of, or checking for, direct-reading and non-direct-reading dosimetry for emergency workers; questions regarding the individual's objectives and locations expected to be visited and associated time frames; availability of maps and plots of radiation exposure rates; advice on areas to avoid; and procedures for exit including: monitoring of individuals, vehicles, and equipment; decision' criteria regarding decontamination; and proper disposition of emergency worker dosimetry and maintenance of emergency worker radiation exposure records. Responsible OROs should demonstrate the capability to develop a strategy for authorized re-entry of individuals into the restricted zone, based on established decision criteria.

OROs should demonstrate the capability to modify those policies for security purposes (e.g.,

police patrols), for maintenance of essential services (e.g., fire protection and utilities), and for other critical functions. They should demonstrate the capability to use decision-making criteria in allowing access to the restricted zone by the public for various reasons, such as to maintain property (e.g., to care'for farm animals or secure machinery, for storage), or to retrieve important possessions. Coordinated policies"for access and exposure control should be developed among all agencies with roles to perform in the restricted zone. OROs should demonstrate the capability to establish policies for provision of dosimetry to all individuals allowed to re-enter the restricted zone. The extent that OROs need to develop policies on re-entry will be determined by scenario events.

Return: Decisions are to be based on environmental data and political boundaries or physical/geological features, which allow identification of the boundaries of areas to which members of the general public may return. Return is permitted to the boundary of the restricted area that is based on the relocation PAG.

Other factors that the ORO should consider are, for example: conditions that permit the cancellation of the Emergency Classification Level and the relaxation of associated restrictive measures; basing return recommendations (i.e., permitting populations that were previously evacuated to reoccupy their homes and businesses on an unrestricted basis) on measurements of radiation from ground deposition; and the capability to identify services and facilities that require restoration within a few days and to identify the procedures and resources for their restoration.

Examples of these services and facilities are: medical and social services, utilities, roads, schools, and intermediate term housing for relocated persons.

PEMA Negotiated Extent of Play:

This sub-element will not be demonstrated or evaluated during this exercise.

EVALUATION AREA 3 Protective Action Implementation 143

Unclassified Radiologica'l Emergency Preparedness Program (REP)

After Action Report/Improvement Plan Three Mile Island Nuclear Generating Station Sub-element 3.a - Implementation of Emergency Worker Exposure Control INTENT This sub-element derives from NUREG-0654, which provides that OROs should have the capability to provide for the following: distribution, use, collection, and processing of direct-reading dosimetry and permanent record dosimetry; the reading of direct-reading dosimetry by emergency workers at appropriate frequencies; maintaining a radiation dose record for each emergency worker; and establishing a decision chain or authorization procedure for emergency workers to incur radiation exposures in excess of protective action guides, always applying the ALARA (As Low As is Reasonably Achievable) principle as appropriate.

Criterion 3.a.l: The OROs issue appropriate dosimetry and procedures, and manage radiological exposure to emergency workers in accordance with the plans and procedures. Emergency workers periodically and at the end of each mission read their dosimeters and record the readings on the appropriate exposure record or chart. (NUREG-0654, K.3.a, b)

EXTENT OF PLA Y OROs should demonstrate the capability to provide appropriate direct-reading and permanent record dosimetry, dosimeter chargers, and instructions on the use of dosimetry to emergency workers. For evaluation purposes, appropriate direct-reading dosimetry is defined as dosimetry that allows individual(s) to read the administrative reporting limits (that are pre-established at a level low enough to consider subsequent calculation of Total Effective Dose Equivalent) and maximum exposure limits (for those emergency workers involved in life saving activities) contained in the ORO's plans and procedures.

Each emergency worker should have the basic knowledge of radiation exposure limits as specified in the ORO's plan and/or procedures. Procedures to monitor and record dosimeter readings and to manage radiological exposure control should be demonstrated.

During a plume phase exercise, emergency workers should demonstrate the procedures to be followed when administrative exposure limits and turn-back values are reached. The emergency worker should report accumulated exposures during the exercise as indicated in the plans and procedures. OROs should demonstrate the actions described in the plan and/or procedures by determining whether to replace the worker, to authorize the worker to incur additional exposures or to take other actions. If scenario events do not require emergency workers to seek authorizations for additional exposure, evaluators should interview at least two emergency workers, to determine their knowledge of whom to contact in the event authorization is needed and at what exposure levels.

144 40

Unclassified Radiological Emergency Preparedness Program (REP)

After Action Report/Improvement Plan Three Mile Island Nuclear Generating Station Emergency workers may use any available resources (for example, written procedures and/or co-workers) in providing responses.

Although it is desirable for all emergency workers to each have a direct-reading dosimeter, there may be situations where team members will be in close proximity to each other during the entire mission and adequate control of exposure can be affected for all.members of the team by one dosimeter wom by the team leader.,

Emergency workers who are assigned to low exposure rate areas, for example,, at reception centers, counting laboratories, emergency operations centers, and communications centers, may have individual directreading dosimeters or they may be monitored by dosimeters strategically placed in the work area. It should be noted that, even in these situations, each team member must still have their own permanent record dosimetry. Individuals without specific radiological response missions, such as farmers for animal care, essential utility service personnel, or other members of the public who must re-enter an evacuated area following or during the plume passage, should be limited to the lowest radiologicaiexposure commensurate With completing their missions.

All activities must be based on the ORO's plans and procedures and completed, as they would be in an actual emergency, unless noted above or otherwise indicated in the extent of play agreement.

PEMA Negotiated Extent of Play:

Radiological briefings (either verbal or video) will be provided to address exposure limits and procedures to replace those approachinglimits and how permission to exceed limits is obtained from the municipality and county. Emergency workers will also be briefed on when to take KI and on whose authority. Distribution of KI will be simulated The completion of a "Dosimetry-KI Report Form" will be demonstrated OROs should also demonstrate the use of all applicable dosimetry forms.

At any time, players may ask other players or supervisors to clarify radiological information.

In Pennsylvania, emergency workers outside of the EPZ do not have turn back values.

Emergency workers who are assigned to low exposure rate areas, e.g., at counting laboratories, emergency operations centers, and communications centers, may have individual permanent record dosimeters or they may be monitored by dosimeters strategically placed in the work area.

In Pennsylvania this will be accomplished through the use of an area kit. The area kit process is explained in state, county and municipal plans.

145

Unclassified Radiological Emergency Preparedness Program (REP)

After Action Report/Improvement Plan Three Mile Island Nuclear Generating Station Standard issue of dosimetry and potassium iodide for each category of emergency worker is as follows:

Category A: 1 PRD, 1 DRD, and 1 unit of KI Category B: 1 PRD and 1 unit of K!

Category C.. 1 PRD All locations that have dosimetry equipment indicated within their Radiological Emergency Response Plan (RERP), will make the dosimetry equipment (and K[) available.for inspection by the federal evaluator. In order to demonstrate an understanding of the use of the dosimetry equipment, KI and associated.forms; the location need only remove and distribute / issue a maximum of six (6) units of dosimetry from their inventory. Simulation PRDs with mock serial numbers may be used if actual PRD's are not demonstrated.

Some counties maintain the inventories of municipal dosimetry and KI at a central location. For evaluation these counties may distribute simulated or real units for the exercise. Some may predistribute the instrument packages to the municipalities in advance of the drill. If the county predistributes dosimetry and KI the plans would specify how and at what point they would be disbursed in a real event. County and Municipal personnel should be able to explain the county to municipal distribution process. Municipalities will be able to demonstrate the dispersal, documentation, and administration of the dosimetry and KI including the reading and zeroing of DRD 's.

Sub-element 3.b - Implementation of KI Decision INTENT This sub-element derives from NUREG-0654, which provides that Offsite Response Organizations (ORO) should have the capability to provide radio protective drugs for emergency workers, institutionalized individuals, and, if in the plan and/or procedures, to the general public for whom immediate evacuation may not be feasible, very difficult, or significantly delayed. While it is necessary for OROs to have the capability to provide KI to emergency workers and institutionalized individuals, the provision of KI to the general public is an ORO option and is reflected in ORO's plans and procedures. Provisions should include the availability of adequate quantities, storage, and means of the distribution of radio protective drugs.

Criterion 3.b.l: KI and appropriate instructions are available should a decision to recommend use of KI be made. Appropriate record keeping of the administration of KI for emergency workers and institutionalized individuals is maintained.

(NUREG-0654, J. 10. e) 146 a

Unclassified Radiological Emergency Preparedness Program (REP)

After Action Report/Improvement Plan Three Mile Island Nuclear Generating Station EXTENT OF PLAY Offsite Response Organizations (ORO) should demonstrate the capability to make KI available to emergency workers, institutionalized individuals, and, where provided for in the ORO pian and/or procedures, to members of the general public. OROs should demonstrate the capability to accomplish distribution of KI consistent with decisions made.

Organizations should have the capability to develop and maintain lists of emergency workers and institutionalized individuals who have ingested KI, including documentation of the date(s) and time(s) they were instructed to ingest KI. The ingestion of KI recommended by the designated ORO health official is:voluntary.

For evaluation purposes, the actual ingestion of KI is hot necessary. OROs should demonstrate the capability to formulate and disseminate appropriate instructions on the use of KI for those advised to take it. If a recommendation is made for the general, public to take KI, appropriate information should be provided to the public by the means of notification specified in the ORO's plan and/or procedures..

Emergency workers should demonstrate the basic knowledge of procedures for the use of KI whether or not the scenario drives the use of K1.

This can be accomplished through an interview by the evaluator..

All activities must be' based on the ORO's plans and procedures and completed as they would be in an actual emergency, unless noted above or otherwise indicated in the extent of play agreement.

PEMA Negotiated Extent of Play:

Within Pennsylvania, the Pennsylvania Department of Health is responsible for distribution of KI to the general public located within the EPZ. Pre-distribution is accomplished on an annual basis. KI is not distributed to the general public at the time of an emergency.

Evaluation of emergency worker KI quantities will be verified using inventory sheets. KI will not be removed from storage locations and boxes will not be opened. KI questions will be addressed through interviews.

Personnel assigned to operate Monitoring/Decontamination Centers and Stations are not issued DRDs or KI since the centers/stations are located outside the EPZ. Each may be issued a simulated PRD with mock serial numbers if actual PRD's are not demonstrated Sub-element 3.c - Implementation of Protective Actions for Special Populations 147

Unclassified Radiological Emergency Preparedness Program (REP)

After Action Report/Improvement Plan Three Mile Island Nuclear Generating Station INTENT This sub-element derives from NUREG-0654, which provides that Offsite Response Organizations (ORO) should have the capability to implement protective action decisions, including evacuation and/or sheltering, for all special populations. Focus is on those special populations that are (or potentially will be) affected by a radiological release from a nuclear power plant.

Criterion 3.c.I: Protective action decisions are implemented for special populations other than schools within areas subject to protective actions. (NUREG-0654, J.10.c.d.g)

EXTENT OF PLAY Applicable OROs should demonstrate the capability to alert and notify (for example, provide protective action recommendations and emergency information and instructions) special populations (hospitals, nursing homes, correctional facilities, mobility impaired individuals, transportation dependent,, etc.). OROs should demonstrate the capability to provide for the needs of special populations in accordance with the ORO's plans and procedures.

Contact with special populations and reception facilities may be actual or simulated, as agreed to in the Extent of Play. Some contacts with transportation providers should be actual, as negotiated in the extent of play. All actual and simulated contacts should be logged.

All implementing activities associated with protective actions for special populations must be based on the ORO's plans and procedures and completed, as they would be in an actual emergency, unless noted above or otherwise indicated in the extent of play agreement.

PEMA Negotiated Extent of Play:

The names, locations and contact information of identified individuals with identified special needs are maintained on a list at their respective municipal EOC (based upon residential jurisdiction). Copies of these lists will not be provided to the evaluators; however, evaluators will be allowed to inspect the lists during the exercise. Initial contact, by the county, with special populations (hospitals, nursing homes and county correctional facilities) will be actual. All subsequent calls will be simulated. Actual contacts (up to two per Risk County) will be made with transportation providers per their plan. All actual and simulated contacts should be logged 148

Unclassified Radiological Emcrgency Preparedness Program (REP)

After Action Report/Improvement Plan Three, Mile Island Nuclear Generating Station Criterion 3.c.2: OROs/School officials implement protective actions for schools.

(NUREG-0654, J.1O.c, d, g)

EXTENT OF PLAY Public school systems/districts shall demonstrate the ability to implement protective action decisions for students. The demonstration shall be made as follows: At least one school in each affected school system or district, as appropriate, needs to demonstrate the implementation of protective actions. ý-The implementation of canceling the school day, dismissing early, or sheltering should be simulated by describing to evaluators the procedures that would be followed.

If evacuation is the implemented protective action, all activities to coordinate and complete the evacuation of students to reception centers, congregate care centers, or host schools may actually be demonstrated or accomplished through an interview process. If accomplished through an interview process, appropriate school personnel including decision making officials (e.g.,

superintendent/principal, transpoitation directoi/bus dispatcher), and at least one bus driver (and the bus driver's escort, if applicable) shAould be avaiilable to demonstrate knowledge of their role(s) in the evacuation of school children. Communications capabilities between school officials and the buses, if required by the plan and/or procedures, should be verified.

Officials of the school system(s) should demonstrate the capability to develop and provide timely information to OROs for use in messages to parents, the general public, and the media on the status of protective actions for schools.

The provisions of this criterion also apply to any private schools, private kindergartens and day care centers that participate in REP exercises pursuant to the ORO's plans andprocedures as negotiated in the Extent of Play Agreement.

All activities must be based on the ORO's plans and procedures and completed, as they would be in an actual emergency, unless noted above or otherwise indicated in the extent of play agreement.

PEMA Negotiated Extent of Play:

School students will not be involved during the exercise. Actions and activities associated with the demonstration of Criterion 3. c. 2 will be limited to the school district administration key personnel and the county. Evacuation ofstudents will be conducted through an interview process with school district personnel or the building principal.

149

Unclassified Radiological Emergency Preparedness Program (REP)

After Action Rcport/Improvement Plan Three Mile Island Nuclear Generating Station The role of the bus driver may be conducted through an interview with school or transportation officials (or designee) if a bus driver is not available. Actual demonstration of the bus route is not required and will not be demonstrated Maps or route descriptions will be available for illustration purposes.

Risk county school plans do not require communications between the school and vehicles. Bus drivers are not considered emergency workers and therefore do not require dosimetry.

Private schools, private kindergartens, and day care centers do not participate in REP exercises.

However, OROs will be prepared to show evaluators lists of these facilities that they will contact in the event of an emergency in accordance with plans and procedures. Any simulated contacts should be logged Sub-element 3.d. - Implementation of Traffic and Access Control INTENT This sub-element derives from NUREG-0654, which provides that Offsite Response Organizations (ORO) have the capability to implement protective action plans, including relocation and restriction of access to evacuated/sheltered areas. This sub-element focuses on selecting, establishing, and staffing of traffic and access control points and removal of impediments to the flow of evacuation traffic.

Criterion 3.d.l: Appropriate traffic and access control is established. Accurate instructions are provided to traffic and access control personnel. (NUREG-0654, J.10.g, j)

EXTENT OF PLAY OROs should demonstrate the capability to select, establish, and staff appropriate traffic and access control points, consistent with protective action decisions (for example, evacuating, sheltering, andrelocation), in a timely manner.

OROs should demonstrate the capability to provide instructions to traffic and access control staff on actions to take when modifications in protective action strategies necessitate changes in evacuation patterns or in the area(s) where access is controlled.

Traffic and access control staff should demonstrate accurate knowledge of their roles and responsibilities. This capability may be demonstrated by actual deployment or by interview, in accordance with the extent of play.

150 4

Unclassified Radiological Emergency Preparedness Program (REP)

After Action Report/Improvement Plan Three Mile Island Nuclear Generating Station In instances where OROs lack the authority necessary to control access by certain types of traffic (rail, water, and air traffic), they should demonstrate the capability to contact the State or Federal agencies who have the authority to control access.

All activities must be based on the ORO's plans and procedures and completed as they would be in an actual emergency, unlessonoted above or otherwise indicated in the extent of play agreement.

PEMA Negotiated Extent of Play:

Municipal traffic and access control will be demonstrated by interview at the applicable EOC of jurisdiction. The traffic/access control personnel will not be deployed to the traffic/access control point(s). If the designated assignment is a location within the EPZ, a radiological briefing will be provided to the assigned individuals.

Criterion 3.d.2: Impediments to evacuation are identified and resolved. (NUREG-0654, J.10.k)

EXTENT OF PLAY OROs should demonstrate the capability, as required by the scenario, to identify and take appropriate actions concerning impediments to evacuation. Actual dispatch of resources to deal with impediments, such as wreckers, need not be demonstrated; however, all contacts, actual or simulated, should be logged.

All activities must be based on the ORO's plans and procedures and completed, as they would be in an actual emergency, unless noted above or otherwise indicated in the extent of play agreement.

PEMA Negotiated Extent of Play:

ORO's should demonstrate the capability, as required by the scenario, to identify and take appropriate actions concerning impediments to evacuation. Actual dispatch of resources to deal with impediments, such as tow trucks, need not be demonstrated, however, simulated contacts will be logged Sub-element 3.e - Implementation of Ingestion Pathway Decisions 151

Unclassified Radiological Emergency Preparedness Program (REP)

After Action Report/Improvement Plan.

Three Mile Island-Nuclear Generating Station INTENT This sub-element is derived from NUREG-0654, which provides that OROs should have the capability to implement protective actions, based on criteria recommended by current Food and Drug Administration guidance, for the ingestion pathway zone (IPZ), the area within an approximate 50-mile radius of the nuclear power plant. This sub-element focuses on those actions required for implementation of protective actions.

Criterion. 3.e.l: The ORO demonstrates the availability and appropriate use of adequate information regarding water, food supplies, milk, and agricultural production within the ingestion exposure pathway emergency planning zone for implementation of protective actions. NUREG-0654, J.9, 11)

EXTENT OF PLAY Applicable ORO's should demonstrate the capability to secure and utilize current information on the locations of dairy farms, meat and poultry producers, fisheries, fruit growers, vegetable growers, grain producers, food processing plants, and water supply intake points to implement protective actions within the ingestion pathway EPZ.

ORO's should use Federal resources as identified in the FRERP, and other resources (e.g.,

compacts, nuclear insurers, etc.), if available. Evaluation of this criterion will take into consideration the level of Federal and other resources participating in the exercise.

All activities must be based on the ORO's plans and procedures and completed, as they would be in an actual emergency, unless noted above or otherwise indicated in the extent of play agreement.

PEMA Negotiated Extent of Play:

This sub-element will not be demonstrated or evaluated during this exercise.

Criterion 3.e.2: Appropriate measures, strategies, and pre-printed instructional material are developed for implementing protective action decisions for contaminated water, food products, milk, and agricultural production. (NUREG-0654, J.9, 11) 152 4

Unclassified Radiological Emergency Preparedness Program (REP)

After Action Report/Improvement Plan Three Mile Island Nuclear Generating Station EXTENT OF PLAY Development of measures and strategies for implementation of IPZ protective actions should be demonstrated by formulation.of protective action information for the general public and food producers and processors. This includes either pre-distributed public information material in the IPZ or the capability for the rapid reproduction and distribution of appropriate reproduction-ready information and instructions to pre-determined individuals and businesses. ORO's should demonstrate the capability to control, restrict or prevent distribution of contaminated food by commercial sectors. Exercise play should include demonstration of communications and coordination between organizations to implementprotective actions.. Actual field play of implementation activities may be simulated. For example, communications and coordination with agencies responsible for enforcing food controls within the IPZ should be demonstrated, but actual communications with food producers and processors may be simulated.

All activities must be based on the ORO's plans and procedures and completed, as they would be in an actual emergency, unless noted above or otherwise indicated in the extent of play agreement.

PEMA Negotiated Extent of Play:

This sub-element will not be demonstrated or evaluated during this exercise.

Sub-element 3.f-Implementation of Relocation, Re-entry, and Return Decisions INTENT This sub-element is derived from NUREG-0654, which provides that Offsite Response Organizations (ORO) should demonstrate the capability to implement plans, procedures, and decisions for relocation, re-entry, and return. Implementation of these decisions is essential for the protection of the public from the direct long-term exposure to deposited radioactive materials from a severe accident at a commercial nuclear power plant.

Criterion 3.f.1: Decisions regarding controlled re-entry of emergency workers and relocation and return of the public are coordinated with appropriate organizations and implemented. (NUREG-0654, M.1, 3) 153

Unclassified Radiological Emergency Preparedness Program (REP)

After Action Report/Improvement Plan Three Mile Island Nuclear Generating Station EXTENT OF PLAY Relocation: OROs should demonstrate thel capability to coordinate and implement decisions concerning relocation of individuals, not previously evacuated, to an area where radiological contamination will not expose the general public to doses that exceed the relocation PAGs. OROs should also demonstrate the capability to provide for short-term or long-term relocation of evacuees who lived in areas that have residual radiation levels above the PAGs. Areas of consideration should include the capability to communicate with OROs regarding timing of actions, notification of the population of the procedures for relocation, and the notification of, and advice for, evacuated individuals who will be converted to relocation Status in situations where they will not be able to return to their homes due to high levels of contamination. OROs should also demonstrate the capability to communicate instructions to the public regarding relocation decisions. ORO's should also demonstrate the capability to provide for short-term or long-term relocation of evacuees who lived in areas thathave residual radiation levels above the (first -, second -, and fifty-year) PAG's.

Re-entry: OROs should demonstrate the capability to control re-entry and exit of individuals.who need to temporarily re-enter the restricted area, to protect them from unnecessary radiation exposure and for exit.of vehicles and other equipment to control the spread of contamination outside the restricted area. Monitoring and decontamination facilities will be established as appropriate.

Examples of control procedure subjects are: (1) the assignment of, or checking for, direct-reading and non-direct-reading dosimetry for emergency workers; (2) questions regarding the individuals' objectives and locations expected to be visited and associated timeframes; (3) maps and plots of radiation exposure rates; (4) advice on areas to avoid; and procedures for exit, including monitoring of individuals, vehicles, and equipment, decision criteria regarding contamination, proper disposition of emergency worker dosimetry, and maintenance of emergency worker radiation exposure records.

Return: OROs should demonstrate the capability to implement policies concerning return of members of the public to areas that were evacuated during the plume phase. OROs should demonstrate the capability to identify and prioritize services and facilities that require restoration within a few days, and to identify the procedures and resources for their restoration. Examples of these services and facilities are medical and social services, utilities, roads, schools, and intermediate term housing for relocated persons. Communications among OROs for relocation, re-entry, and return may be simulated; however all simulated or actual contacts should be documented. These discussions may be accomplished in a group setting. OROs should use Federal resources as identified in the FRERP, and other resources (e.g., compacts, nuclear insurers, etc.), if available. Evaluation of this criterion will take into consideration the level of Federal and other resources participating in the exercise. All activities must be based on the ORO's.plans and procedures and completed, as they would be in an actual emergency, unless

  • noted above or otherwise indicated in the extent of play agreement.

.154 a

Unclassified Radiological Emergency Preparedness Program (REP)

After Action Report/Improvement Plan Three Mile Island Nuclear Generating Station PEMA Negotiated Extent of Play:

This sub-element will not be demonstrated or evaluated during this exercise.

EVALUATION AREA 4 Field Measurement and Analysis Sub-element 4.a - Plume Phase Field Measurements and Analyses INTENT This sub-element derives from NUREG-0654, whichf provides that OROs should have the capability to deploy field teams with the equipment, methods, and expertise necessary to determine the location of airborne radiation and particulate deposition on the ground from an airborne plume. In addition, NUREG-0654 indicates that OROs should have the capability to use field teams within the plume emergency planning zone to measure airborne radioiodine in the presence of noble gases and to measure radiactivke particulatematerial in the airborne plume. In the event of an accident at a nuclear power plant, the possible release of radioactive material may pose a risk to the nearby population and environment. Although accident assessment methods are available to project the extent and magnitude of a release, these methods are subject to large uncertainties. During'an accident, it is important to collect field radiological data in order to help characterize anyradiological release. Adequate equipment and procedures are essential to Such field measurement eff0rts.

Criterion 4.a.1: The field teams are equipped to perform field measurements of direct radiation exposure,(cloud and ground shine) and to sample airborne radioiodine and particulates. (NUREG-0654, H.10; 1.7, 8, 9).

EXTENT OF PLAY Field teams should be-equipped with all instrumentation and supplies necessary to accomplish their mission. This should include instruments capable of measuring gamma exposure rates and detecting the presence of beta radiation. These instruments should be capable of measuring a range of activity and exposure, including radiological protection/exposure control of team members and detection of activity on the air sample collection media, consistent with the intended use of the instrument and the ORO's plans and procedures. An appropriate radioactive check source should be used to verify proper operational response for each low range radiation measurement instrument (less than 1 R/hr) and for high range instruments when available. If a source is not available for a high range instrument, a procedure should exist to operationally test the instrument before entering an area where only a high range instrument can make useful readings.

155

Unclassified Radiological Emergency Preparedness Program (REP)

After Action Report/Improvement Plan Three Mile Island Nuclear Generating Station All activities must be based on the ORO's plans and procedures and completed as they would be in an actual emergency, unless noted above or otherwise indicated in the extent of play agreement.

PEMA Negotiated Extent of Play:

This sub-element will not be evaluated during this exercise.

Criterion 4.a.2: Field teams are managed to obtain sufficient information to help characterize the release and to control radiation exposure. (NUREG-0654, H.12; 1.8., 11; J.10.a).

EXTENT OF PLAY Responsible Offsite Response Organizations (ORO) should demonstrate the capability to brief teams on predicted plume location and direction, travel speed, and exposure control procedures before deployment.

Field measurements are needed to help characterize the release and to support the adequacy of implemented protective actions or to be a factor in modifying protective actions. Teams should be directed to take measurements in such locations, at such times to provide information sufficient to characterize the plume and impacts.

If the responsibility to obtain peak measurements in the plume has been accepted by licensee field monitoring teams, with concurrence from OROs, there is no requirement for these measurements to be repeated by State and local monitoring teams. If the licensee teams do not obtain peak measurements in the plume, it is the ORO's decision as to whether peak measurements are necessary to sufficiently characterize the plume. The sharing and coordination of plume measurement information among all field teams (licensee, federal, and ORO) is essential.

Coordination concerning transfer of samples, including a chain-of-custody form, to a radiological laboratory should be demonstrated.

OROs should use Federal resources as identified in the Federal Radiological Emergency Response Plan (FRERP), and other resources (for example, compacts, utility, etc), if available. Evaluation of this criterion will take into consideration the level of Federal and other resources participating in the exercise.

All activities must be based on the ORO's plans and procedures and completed as they would be in an actual emergency, unless noted above or otherwise indicated in the extent of play agreement.

156 0

Unclassified Radiological Emergency Preparedness Program (REP)

After Action Report/Improvement Plan Three Mile Island Nuclear Generating Station PEMA Negotiated Extent of Play:

This sub-element will not be evaluated during this exercise.

Criterion 4.a.3: Ambient radiation measurements are made and recorded at appropriate locations, and radioiodine and particulate samples are collected. Teams will move to an appropriate low background location to determine whether any significant (as specified in the plan and/or procedures) amount of radioactivity has been collected on the sampling media. (NUREG-0654, I. 9).

EXTENT OF PLAY Field teams should demonstrate the capability to report measurements and field data pertaining to the measurement of airborne radioiodine and particulates and ambient radiation to the field team coordinator, dose assessment, or other appropriate authority. If samples have radioactivity significantly above background, the appropriate authority should consider the need for expedited laboratory analyses of these samples. OROs should share data in a timely manner with all appropriate OROs. All methodology, including contamination control, instrumentation, preparation of samples, and a chain-of-custody form for transfer to a laboratory, will be in accordance with the ORO plan and/or procedures.

OROs* should use Federal resources as identified in the FRERP, and other resources (for example, compacts, utility, nuclear insurers, etc), if available.,; Evaluation of this criterion will take into, consideration the level of Federal and other resources participating in the exercise.

All activities must be based on the ORO's plans and procedures and completed as they would be in an actual emergency, unless noted above or otherwise indicated in the extent of play agreement.

PEMA Negotiated Extent of Play:

This sub-element will not be evaluated during this exercise.

Sub-element 4.b - Post Plume Phase Field Measurements and Sampling INTENT This sub-element is derived from NUREG-0654, which provides that OROs should have the capability to assess the actual or potential magnitude and locations of radiological hazards in the IPZ and for relocation, re-entry and return measures.

This sub-element focuses on the collection of environmental samples for laboratory analyses that are essential for decisions on protection of the public from contaminated food and water and direct radiation from deposited materials.

157

Unclassified Radiological Emergency Preparedness Program (REP)

After Action Report/Improvement Plan Three Mile Island Nuclear Generating Station Criterion 4.b.l: The field teams demonstrate the capability to make appropriate measurements and to collect appropriate samples (e.g., food crops, milk, water, vegetation, and soil) to support adequate assessments and protective action decision-making. (NUREG-0654, 1.8; J.11)

EXTENT OF PLAY The ORO's field team should demonstrate the capability to take measurements and samples, at such times and locations as directed, to enable an adequate assessment of the ingestion pathway and to support re-entry, relocation, and return decisions. When resources are available, the use of aerial surveys and in-situ gamma measurement is appropriate. All methodology, including contamination control, instrumentation, preparation of samples, and a chain-of-custody form for transfer to a laboratory, will be in accordance with the ORO's plan and/or procedures; Ingestion pathway samples should be secured from agricultural products and water. Samples in support of relocation and return should be secured from soil, vegetation, and other surfaces in areas that received radioactive ground deposition.,

OROs should use Federal resources as identified in the FRERP, and other resources (e.g.,

compacts, utility, nuclear insurers, etc.), if available. Evaluation of this criterion will take into consideration the level of Federal and other resources participating in the exercise.

All activities must be based on the ORO's plans and procedures and completed, as they would be in an actual emergency, unless noted above or otherwise indicated in the extent of play agreement.

PEMA NEGOTIA TED EXTENT OF PLAY:

This sub-element will not be evaluated during this exercise.

Sub-element 4.c - Laboratory Operations INTENT This sub-element is derived from NUREG-0654, which provides that Offsite Response Organizations (ORO) should have the capability to perform laboratory analyses of radioactivity in air, liquid, and environmental samples to support protective action decision-making.

Criterion 4.c.I: The laboratory is capable of performing required radiological analyses to support protective action decisions. (NUREG-0654, C.3; J.11) 158 0

Unclassified Radiological Emergency Preparedness Program (REP)

After Action Report/Improvement Plan Three Mile Island Nuclear Generating Station EXTENT OF PLAY The laboratory staff should demonstrate the capability to follow appropriate procedures for receiving samples, including logging of information, preventing contamination of the laboratory, preventing buildup of background radiation due to stored samples, preventing cross contamination of samples, preserving samples that may spoil (e.g., milk),:and keeping track of sample identity. In addition, the laboratory staff should demonstrate the capability. to 'prepareý samples for conducting measurements.

The laboratory should be appropriately, equipped to provide; analyses of media, as requested, on a timely basis, of sufficient quality and sensitivity to support assessments and decisions as anticipated by the ORO's plans and procedures. The laboratory (laboratories) instrument calibrations should be traceable to standards provided by theNational Institute of Standards and Technology. Laboratory methods used to analyze typical radionuclides: released in. a reactor. incident should be as described in the plans and procedures. New or revised methods may be used to, analyze: atypical radionuclide releases (e.g.,

transuranics or as a result of a terrorist event) or if warranted by circumstances of the event. Analysis may require resources.beyond&those of:the ORO.,

The laboratory staff should be qualified in radioanalytical techniques and contamination control procedures.

OROs should use Federal resources as identified in the FRERP, and other resources (e.g.,

compacts, utility, nuclear insurers, etc.), if available. Evaluation of this criterion will take into consideration the level of Federal and other resources participating in the exercise.

All activities must be based on the ORO's plans and procedures and completed, as they would be in an actual emergency, unless noted above or otherwise indicated in the extent of play agreement.

PEMA NEGOTIA TED EXTENT OF PLA Y:

This sub-element will not be evaluated during this exercise.

EVALUATION AREA 5 Emergency Notification and Public Information 159

Unclassified Radiological Emergency Preparedness Program (REP)

After Action Report/Improvement Plin Three Mile Island Nuclear Generating Station Sub-element 5.a - Activation of the Prompt Alert and Notification System INTENT This sub-element derives from NUREG-0654, which provides that OROs should have the capability to provide prompt instructions to the public within the plume pathway EPZ. Specific provisions addressed in this sub-element are derived from the Nuclear Regulatory Commission (NRC) regulations (10 CFR Part 50, Appendix E.1V.D.), and FEMA-REP-10, "Guide for the Evaluation of Alert and Notification systems for Nuclear Power Plants."

Criterion 5.a.l: Activities associated with primary alerting and notification of the public are completed in a timely manner following the initial decision by authorized offsite emergency officials to notify the public of an emergency situation. The initial instructional message to the public must include as a minimum the elements required by current FEMA REP guidance. (10 CFR Part 50, Appendix E.IV.D and NUREG-0654, E.5, 6, 7)

EXTENT OF PLA Y Responsible Offsite Response Organizations (ORO) should demonstrate the capability to sequentially provide an alert signal followed by an initial instructional message to populated areas (permanent resident and transient) throughout the 10-mile plume pathway EPZ. Following the decision to activate the alert and notification system, in accordance with the ORO's plan and/or procedures, completion of system activation should be accomplished in a timely manner (will not be subject to specific time requirements) for primary alerting/notification. The initial message should include the elements required by current FEMA REP guidance.

Offsite Response Organizations (OROs) with route alerting as the primary method of alerting and notifying the public should demonstrate the capability to accomplish the primary route alerting, following the decision to activate the alert and notification system, in a timely manner (will not be subject to specific time requirements) in accordance with the ORO's plan and/or procedures, At least one route needs to be demonstrated and evaluated.

The selected route(s) should vary from exercise to exercise. However, the most difficult route should be demonstrated at least once every six years. All alert and notification activities along the route should be simulated (that is, the message that would actually be used is read for the evaluator, but not actually broadcast) as agreed upon in the extent of play. Actual testing of the mobile public address system will be conducted at some agreed upon location. The initial message should include the elements required by current FEMA REP guidance.

160 40

Unclassified Radiological Emergency Preparedness Program (REP)

After Action Report/Improvement Plan Three Mile Island Nuclear Generating Station For exercise purposes, timely is defined as "the responsible ORO personnel/representatives demonstrate actions to disseminate the appropriate information/instructions with a sense of urgency and without undue delay."

If message dissemination;is to be identified as not.having been accomplished in a timely manner, the evaluator(s) will document a specific delay or cause as to why a message was not considered timely.

Procedures to broadcast the message should be fully demonstrated as they would in an actual emergency up tothe point of transmission.. Broadcast of the message(s) or test messages is not required. The alert signal activation may be simulated. However, the procedures should be demonstrated up to the point of actual activation..

The capability of the primary notification system to broadcast an instructional message on a 24-hour basis should be verified during an'interview witlh appropriate personnel from the primary notification system.

All activities for this criterion must be based on the ORO's plans and procedures and completed as they would be in an actual emergency, except as noted above or otherwise indicated in the extent of play agreement.

PEMA Negotiated Extent of Play:

The Commonwealth of Pennsylvania has' implemented a Statewide EAS Control system in cooperation With the Pennsylvania Association of Broadcasters per the State Emergency Communications Committee and Pennsylvania Emergency Alert System State EAS Plan (April 1, 2004). The State EOC (PEMA) is the initiating point for the activation of the EAS. Risk counties' have the control equipment for activation of sirens.

Coordination will occur between the State EOC and the affected counties with respect to the Alert and Notification System (ANS) process. Sirens will be coordinated and the sounding simulated at the appropriate time with the simulated activation of EAS taking place approximately 3 minutes following the simulated activation of the sirens. Regular broadcasting will not be interrupted on the EAS Stations. All subsequent actions to broadcast stations will be simulated. Broadcast of the message(s) or test message(s) is NOT required and NOT requested Counties may elect to provide county specific EAS messages to their EAS stations.

Following the decision to activate the alert and notification system, in accordance with the ORO's plan and/or procedures, simulated ANS activation should be accomplished in a timely manner for primary alerting/notification. This action will NOT be subject to specific time requirements.

161

Unclassified Radiological Emergency Preparedness Program (REP)

After Action Report/Improvement Plan Three Mile Island Nuclear Generating Station All actions to broadcast stations will be simulated. Systems that use automatic sending technology may be demonstrated by explanation during an interview.

Each evaluated municipality per Risk County will demonstrate route alerting of the hearing impaired residents within theirjurisdiction by interview at the EOC.

Criterion 5.a.2: IRESERVEDi Criterion 5.a.3: Activities associated with FEMA approved exception areas (where applicable) are completed within 45 minutes following the initial decision by authorized offsite emergency officials to notify the public of an emergency situation.

Backup alert and notification of the public is completed within 45 minutes following the detection by the ORO of a failure of the primary alert and notification system.

(NUREG-0654, E. 6, Appendix 3.B.2.c)

EXTENT OF PLAY Offsite Response Organizations (ORO) with FEMA-approved exception areas (identified in the approved Alert and Notification System Design Report) 5-10 miles from the nuclear power plant should demonstrate the capability to accomplish primary alerting and notification of the exception area(s) within 45 minutes following the initial decision by authorized offsite emergency officials to notify the public of an emergency situation. The 45-minute clock will begin when the OROs make the decision to activate the alert and notification system for the first time for a specific emergency situation. The initial message should, at a minimum, include: a statement that an emergency exists at the plant and where to obtain additional information.

For exception area alerting, at least one route needs to be demonstrated and evaluated. The selected route(s) should vary from exercise to exercise. However, the most difficult route should be demonstrated at least once every six years.

All alert and notification activities along the route should be simulated (that is, the message that would actually be used is read for the evaluator, but not actually broadcast) as agreed upon in the extent of play. Actual testing of the mobile public address system will be conducted at some agreed-upon location.

162 0

Unclassified Radiological Emergency Preparedness Program (REP)

After Action Report/Improvement Plan Three Mile Island Nuclear Generating Station Backup alert and notification of the public should be completed within 45 minutes following the detection by the ORO of a failure of the primary alert and notification system. Backup route alerting only needs to be demonstrated and evaluated, in accordance with the ORO's plan and/or procedures and the extent of play agreement, if the exercise scenario calls for failure of any portion of the primary system(s), or if any portion of the primary system(s) actually fails to function. If demonstrated, only one route needs to be selected and demonstrated. All alert and notification activities along the route should be simulated (that is, the message that would actually be used is read for the evaluator, but not actually broadcast) as agreed upon in the extent of play. Actual testing of the mobile public address system will be conducted at some agreed-upon location.

All activities for this criterion must be based on the ORO's plans and procedures and completed as they would be in an actual emergency, except as noted above or otherwise indicated in the extent of play agreement.

PEMA Negotiated Extent of Play:

Back-up alert notification of the public due to a simulated siren failure will be demonstrated.

(Refer to Attachment A,Section I. 4.) The risk county siren operator will receive an inject from the county liaison indicating that a particular siren has failed. This siren failure will then be communicated to the appropriate municipalities so they can demonstrate their back-up route alert response. The back-up route alerting must be completed in no more than 45 minutes from inject to finish of back-up route alert. Pennsylvania does not have any "exception areas."

Sub-element 5.b - Emergency Information and Instructions for the Public and the Media INTENT This sub-element derives from NUREG-0654, which provides that Offsite Response Organizations (ORO) should have the capability to disseminate to the public appropriate emergency information and instructions, including any recommended protective actions. In addition, NUREG-0654 provides that OROs should ensure that the capability exists for providing information to the media. This includes the availability of a physical location for use by the media during an emergency. NUREG-0654 also provides that a system should be available for dealing with rumors. This system will hereafter be known as the public inquiry hotline.

163

Unclassified Radiological Emergency Preparedness Program (REP)

After Action Report/Improvement Plan Three Mile Island Nuclear Generating Station Criterion 5-b.1: OROs provide accurate emergency information and instructions to the public and the news media in a timely manner. (NUREG-0654, E. 5, 7; G.3.a, G.4.c)

EXTENT OF PLAY Subsequent emergency information and instructions should be provided to the public and the media in a timely manner (will not be subject to specific time requirements). For exercise purposes, timely is defined as "the responsible ORO personnel/representatives demonstrate actions to disseminate the appropriate information/instructions with a sense of urgency and without undue delay." If message dissemination is to be identified as not having been accomplished in a timely manner; the evaluator(s) will document a specific delay or cause as to why a message was not considered timely.

The ORO should ensure that emergency information and instructions are consistent with protective action decisions made by appropriate officials. The emergency information should contain all necessary and applicable instructions (for example, evacuation instructions, evacuation routes, reception center locations, what to take when evacuating, information concerning pets, shelter-in-place instructions, information concerning protective actions for schools and special populations, public inquiry telephone number, etc.) to assist the public in carrying out protective action decisions provided to them.

The ORO should also be prepared to disclose and explain the Emergency Classification Level (ECL) of the incident. At a minimum, this information must be included in media briefings and/or media releases. OROs shouild demonstrate the capability to use language that is clear and understandable to the public within both the plume and ingestion pathway EPZs. This includes demonstration of the capability to use familiar landmarks and boundaries to describe protective action areas.

The emergency information should be all-inclusive by including previously identified protective action areas that are still valid, as well as new areas. The OROs should demonstrate the capability to ensure that emergency information that is no longer valid is rescinded and not repeated by broadcast media. In addition, the OROs should demonstrate the capability to ensure that current emergency information is repeated at pre-established intervals in accordance with the plan and/or procedures.

OROs should demonstrate the capability to develop emergency information in a non-English language when required by the plan and/or procedures.

164

Unclassified Radiological Emergency Preparedness Program (REP)

After Action Report/improvement Plan Three Mile Island Nuclear Generating Station If ingestion pathway measures are exercised, OROs should demonstrate that a system exists for rapid dissemination of ingestion pathway information to pre-determined individuals and businesses in accordance with the ORO's plan and/or procedures.

OROs should demonstrate the capability to provide timely, accurate, concise, and coordinated information to the news media for subsequent dissemination to the public. This would include demonstration of the capability to conduct timely and pertinent media briefings and distribute media releases as the situation warrants. The OROs, should demonstrate the capability to respond appropriately to inquiries from the news media. All information presented in media briefings and media releases'should be consistent with protective action decisions and other emergency information provided to the public. CoPies of pertinent emergency information (e.g.,

EAS messages and media releases) and media information kits should be available for dissemination to the media.

OROS should demonstrate that an effective system is in place for dealing with calls to the public inquiry hotline. Hotline Staff should demonstrate the capability to provide or obtain accurate information for callers or refer them to an appropriate information source. Information from the*

hotline staff, including information that corrects falseý or inaccutrate information when trends are noted, should be included, as appropriate, in emergency information provided to the public, media briefings, and/or media releases.

All activities for.this criterion must-be based on the ORO's plans and procedures and completed, as they would be in an actual emergency, unless noted above or otherwise indicated in the extent of play agreement.

PEMA Negotiated Extent of Play:

Subsequent emergency information and instructions should be provided to the public and the media in a timely manner. This Will NOT be subject to specific time requirements. Any.

information/news statements required by the ORO plans will be simulated One media briefing will be demonstrated in each risk county.

Risk and support counties will receive and handle "Public Inquiry" messages via their individual "Public Inquiry" processes (In compliance with NIMS terminology, Rumor Control is now considered to be "Public Inquiry"). Counties will receive approximately ten (10) public inquiry calls from the state exercise cell assigned this responsibility. Counties will be expected to receive and log the calls, identify any trends, and take appropriate actions.

Lancaster County has previously demonstrated and has been exempted from demonstrating this requirement on this exercise.

165

Unclassified Radiological Emergency Preparedniess Program (REP)

After Action Report/Improvement Plan Three Mile Island Nuclear Generating Station EVALUATION AREA 6 Support Operation/Facilities Sub-element 6.a - Monitoring and Decontamination of Evacuees and Emergency Workers and Registration of Evacuees INTENT This sub-element derives from NUREG-0654, which provides that Offsite Response Organizations (ORO) have the capability to implement radiological monitoring and decontamination of evacuees and emergency workers, while minimizing contamination of the facility, and registration of evacuees at reception centers.

Criterion 6.a.l: The reception center/emergency worker facility has appropriate space, adequate resources, and trained personnel to provide monitoring, decontamination, and registration of evacuees and/or emergency workers. (NUREG-0654, J.10.h; J.12; K.5.a)

EXTENT OF PLAY Radiological monitoring, decontamination, and registration facilities for evacuees/ emergency workers should be set up and demonstrated as they would be in an actual emergency or as indicated in the extent of play agreement; This would include adequate space for evacuees' vehicles. Expected demonstration should include 1/3 of the monitoring teams/portal monitors required to monitor 20% of the population allocated to the facility within 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br />. Before using monitoring instrument(s), the monitor(s) should demonstrate the process of checking the instrument(s) for proper operation.

Staff responsible for the radiological monitoring of evacuees should demonstrate the capability to attain and sustain a monitoring productivity rate per hour needed to monitor the 20%

emergency planning zone (EPZ) population planning base within about 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br />. This monitoring productivity rate per hour is the number of evacuees that can be monitored per hour by the total complement of monitors using an appropriate monitoring procedure. A minimum of six individuals per monitoring station should be monitored, using equipment and procedures specified in the plan and/or procedures, to allow demonstration of monitoring, decontamination, and registration capabilities. The monitoring sequences for the first six simulated evacuees per monitoring team will be timed by the evaluators in order to determine whether the twelve-hour requirement can be met. Monitoring of emergency workers does not have to meet the twelve-hour requirement. However, appropriate monitoring procedures should be demonstrated for a minimum of two emergency workers.

166

Unclassified Radiological Emergency Preparedness Program (REP)

After Action Report/Improvement Plan Three Mile Island Nuclear Generating Station Decontamination of evacuees/emergency workers may be simulated and conducted by interview.

The availability of provisions for separately showering should be demonstrated or explained. The staff should demonstrate provisions for limiting the spread of contamination. Provisions could include floor coverings, signs and appropriate means (for example, partitions, roped-off areas) to separate clean from potentially contaminated areas. Provisions should also exist to separate contaminated and uncontaminated individuals, provide changes of clothing for individuals whose clothing is contaminated, and store contaminated clothing and personal belongings to prevent further contamination of evacuees or facilities. In addition, for any individual found to be contaminated, procedures should be discussed concerning the handling of potential contamination of vehicles and personal belongings.,.

Monitoring personnel should explain the use of action levels for determining the need for decontamination. They should also explain the procedures for referring evacuees who cannot be adequately decontaminated for assessment and follow up in accordance with the ORO's plans and procedures. Contamination of the individual will be determined by controller inject and not simulated with any low-level radiation source.

The capability to register individuals upon completion of the monitoring and decontamination activities should be demonstrated. The registration activities demonstrated should include the establishment of a registration record for each individual, consisting of the individual's name, address, results of monitoring, and time of decontamination, if any, or as otherwise designated in the plan. Audio recorders, camcorders, or written records are all acceptable means for registration.

All activities associated with this criterion must be based on the ORO's plans and procedures and completed, as they would be in an actual emergency, unless otherwise indicated in the extent of play agreement..

PEMA Negotiated Extent of Play:

Radiological monitoring demonstration sites should possess a roster of the monitoring personnel required to process 20% of the population allocated to the facility within a 12 hour1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br /> period.

Water from decontamination activities may go directly to a storm drain or other sewer or drain system or area normally designated for wastewater that has been used for bathing or washing of vehicles and or equipment.

167

Unclassified Radiological Emergency Preparedness Program (REP)

After Action Report/Improvement Plan Three Mile Island Nuclear Generating Station At each reception center, a minimum of three volunteer evacuees will be processed, briefed, issued the appropriate strip map or directions, and instructed to proceed to a mass care center designated for demonstration of monitoring, decontamination, and registration. A sample of the appropriate strip maps or directions will be made available for the demonstration. Where the reception center is co-located with the mass care facility, strip maps or written directions are not required.

One mass care center and one mass care monitoring/decontamination center will be demonstrated per county during the out-of-sequence window. The counties will provide space at designated mass care centers for operation of monitoring/decontamination centers. Schematics of these monitoring /decontamination centers will be available to show the organization and layout within the facility and space management for monitoring and decontamination.

Procedures will be demonstrated to show the separation of contaminated and non-contaminated (clean) individuals to minimize cross contamination.

At the Evacuee Monitoring/Decontamination Center, a minimum of six (6) volunteer evacuees will be monitored (or one volunteer evacuee may be monitored six times). Suitable radiological monitoring instruments will be issued to and demonstrated by the initial monitoring team(s). A monitoring team consists of one monitor and one recorder equipped with one survey instrument.

Those individuals found to be free of "contamination ", based upon scenario injects, will be directed to the mass care registration point for further processing. Note: Actual radiological sources will not be attached to or hidden upon the volunteer evacuees.

One of the simulated evacuees, based upon controller injects, will not be able to be decontaminated. Discussions concerning the processing of contaminated personnel will include capabilities and written procedures for showering females separate from males. Showering will be simulated, water will not be used Note: *Ifportal monitors are used, the Portal Monitor Extent of Play described below shall be used.

At the Emergency Worker Monitorinz/Decontamination Stations one emergency worker will be monitored Discussions concerning processing of contaminated personnel will include capabilities and written procedures for showering females separate from males. Showering will be simulated, water will not be used. Suitable radiological monitoring instruments will be issued to the initial monitoring team. Note: Ifportal monitors are used, the Portal Monitor Extent of Play described below shall be used.

Portal monitor Use: Risk and Support counties may, during this exercise, utilize portal monitors to monitor simulated evacuees and/or emergency workers. The monitoring/decontamination team requirements will be based on the portal monitor capabilities as applicable based on the procedure/guidelines, and the recommendations of the manufacturer. Note: PEMA guidance shall apply.

168 0

Unclassified Radiological Emergency Preparedness Program (REP)

After Action Report/nprovement Plan Three Mile Island Nuclear Generating Station Monitoring/decontamination centers and Emergency Worker monitoring and decontamination station personnel are not issued DRDs or KI since the centers and stations are outside the EPZ.

Category "C" dosimetry applies. Simulated permanent record dosimeters (PRDs) will be worn.

Radiation readings/contamination data for the evacuees. and vehicle will be provided by the controller as appropriate based upon information contained in the scenario package. Set-up of the facility will be performed the same as for an actual emergency with all route markings and contamination control measures in place including step-offpads. Long runs ofplastic covered with paper will not be demonstrated, but the materials shall be available and explained.

Positioning of afire apparatus, onsite may be simulated if otherwise required.

Sub-element 6.b - Monitoring and Decontamination of Emergency Worker Equipment INTENT This sub-element derives from NUREG-0654, which provides that Offsite Response Organizations (ORO) have the capability to implement radiologicalmonitoring and decontamination of emergency worker equipment, including vehicles.

Criterion 6.b.l: The facility/ORO has adequate procedures and resources for the accomplishment of monitoring and decontamination of emergency worker equipment, including vehicles. (NUREG-0654, K.5.b)

EXTENT OF PLA Y The monitoring staff should demonstrate the capability to monitor equipment, including vehicles, for contamination in accordance with the Offsite Response Organizations (ORO) plans and procedures. Specific attention should be given to equipment, including vehicles, that was in contact with individuals found to be contaminated. The monitoring staff should demonstrate the capability to make decisions on the need for decontamination of equipment, including vehicles, based on guidance levels and procedures stated in the plan and/or procedures.

The area to be used for monitoring and decontamination should be set up as it would be in an actual emergency, with all route markings, instrumentation, record keeping and contamination control measures in place. Monitoring procedures should be demonstrated for a minimum of one vehicle. It is generally not necessary to monitor the entire surface of vehicles.

However, the capability to monitor areas such as radiator grills, bumpers, wheel wells, tires, and door handles should be demonstrated. Interior surfaces of vehicles that were in contact with individuals found to be contaminated should also be checked.

169

Unclassified Radiological Emergency Preparedness Program (REP)

After Action Report/Improvement Plan Three Mile Island Nuclear Generating Station Decontamination capabilities, and provisions for vehicles and equipment that cannot be decontaminated, may be simulated and conducted by interview.

All activities associated with this criterion must be based on the ORO's plans and procedures and completed as they would be in an actual emergency, unless noted above or otherwise indicated in the extent of play agreement.

PEMA Negotiated Extent of Play:

Emergency worker station personnel will consist of a minimum of one monitor and one recorder and sufficient personnel to demonstrate monitoring of at least one vehicle. Schematics of these monitoring/decontamination stations will be available to show organization and space management. The evaluator will request that vehicle decontamination procedures be explained after the vehicle (with simulated contamination) has been monitored. One radiological survey meter, will be issued to each vehicle monitoring/decontamination team. One vehicle and/or piece of equipment will not be able to be decontaminated Simulated radiation contamination data will be included in the scenario package, and injected by a controller. Set-up of the facility will be performed as closely as possible to that for an actual emergency with all route markings in place.

Decontamination capabilities, and provisions for vehicles and equipment that cannot be decontaminated, will be simulated and conducted by interview. Water will NOT be used.

Sub-element 6.c - Temporary Care of Evacuees INTENT This sub-element derives from NUREG-0654, which provides that Offsite Response Organizations (ORO) demonstrate the capability to establish relocation centers in host areas. The American Red Cross (ARC) normally provides congregate care in support of OROs under existing letters of agreement.

Criterion 6.c.1: Managers of congregate care facilities demonstrate that the centers have resources to provide services and accommodations consistent with American Red Cross planning guidelines. (Found in MASS CARE - Preparedness Operations, ARC 3031) Managers demonstrate the procedures to assure that evacuees have been monitored for contamination and have been decontaminated as appropriate before entering congregate care facilities. (NUREG-0654, J.10.h, J.12) 170

Unclassified Radiological Emergency Preparedness Program (REP)

After Action Report/Improvement Plan Three Mile Island Nuclear Generating Station EXTENT OF PLAY Under this criterion, demonstration of congregate care centers may be conducted out of sequence with the exercise scenario. The evaluator should conduct a walk-through of the center to determine, through observation and inquiries, that the services 'and accommodations are consistent with ARC 3031. In this simulation, it is not necessary to set up operations as they would be in an actual emergency. Alternatively, capabilities may be demonstrated by setting up stations for various services and providing those services to simulated evacuees.

Given the substantial differences between demonstration and simulation of this objective, exercise demonstration expectations should be clearly specified in extent-of-play agreements.

Congregate care staff should also demonstrate~the capability to ensure that evacuees have been monitored for contamination, have been decontaminated as appropriate, and have been registered before entering the facility. This capability-may be determined through an interview process.

If operations at the center are demonstrated, material that would be difficult or expensive to transport (for example, cots, blankets, sundries, 'and large-scale food supplies) need not be, physically available at the facility (facilities). However," availability of such items should be verified by providing the evaluator a list of sources with locations and estimates of quantities.

All activities associated with this criteri6n'must be based on the ORO's plans and procedures and completed, as they would be in an actual emergency, unless noted above or otherwise indicated in the extent of play agreement.

PEMA Negotiated Extent of Play:

All counties demonstrating the operation of mass care centers during the out-of-sequence window will provide floor plans of the mass care'centers to show organization within the facility and space management during a real emergency." 'Mass care center locations are listed in the demonstration tables "Demonstration of Mass Care Centers (Attachment A, Section B. 3) ".

Those counties that have identified more than three mass care facilities would choose one facility to be evaluated along with the monitoring/decontamination segment demonstrating how the both functions would share space Within thefacility and how they would receive and control arriving evacuees. The other facilities scheduledfor evaluation during this evaluation cycle Would demonstrate out-of-sequence. This evaluation would involve county, Red Cross, facility representatives, PEMA, and FEMA. This'walk-through demonstration would allow the evaluator to view the facility, to observe maps, shelter layouts, plans, and other documentation relevant to mass care operations, and to provide an opportunity to interview Red Cross, county, or other persons who would take part in the activation, setup, and operation of the facility.

171

Unclassified Radiological Emergency Preparedness Program (REP)

After Action Report/Improvement Plan Three Mile Island Nuclear Generating Station In most cases the walk through is done at times when the facility is in operation and therefore not all areas (such as locker rooms/showers) may be accessible for evaluation. Each mass care facility must be evaluated by demonstration or walkthrough in every 6 year cycle (T*M or PBAP. ) This out of sequence demonstration window will on Wednesday April 13, 2011from 1:00p.m. to 4:00p.m.

The previously unevaluated Lancaster County mass care facilities that have not been evaluated during the out of sequence portion will be evaluated by walk-through within 30 days of the exercise.

The date(s) and time(s) of evaluation have not yet been determined.

For'those mass care centers demonstrating with monitoring and decontamination teams, the personnel, at a minimum, will consist of one manager and one assistant for each mass care center opened during the out-of-sequence window. The responsible American Red Cross chapter will show the source and quantities, byjob functional description, to be provided to mass care centers to support the 24-hour operational window. Schematics of these mass care centers will be available, during the demonstration window, to show organization within the facility and space allocation for the registration and sheltering the evacuating public. Necessary signs, directional arrows and forms will be available and used to demonstrate registration, at a minimum, of three evacuees requiring emergency housing. Evacuees will be shown the location where they would be housed in an actual situation. Bedding, cots, food, etc. normally associated with mass care will not be moved to the site, but the sources of those items should be explained to FEMA evaluators. This out-of-sequence demonstration window will be from 7:00 PM-9:30 PM on April 13, 2011.

172

Unclassified Radiological Emergency Preparedness Program (REP)

After Action Report/Improvement Plan Three Mile Island Nuclear Generating Station Sub-element 6.d - Transportation and Treatment of Contaminated Injured Individuals This sub-element is derived from NUREG-0654, which provides that Offsite Response Organizations (ORO's) should have the capability to transport contaminated injured individuals to medical facilities with the capability to provide.medical services..

Criterion 6.d.1: The facility/OROlhas the appropriate space, adequate resources, and trained personnel to provide transport, monitoring, decontamination, and medical services to contaminated injured individuals. (NUREG-0654, F.2; H.10; K.5, a, b; L.1, 4)

EXTENT OF PLAY Monitoring, decontamination, and contamination control efforts will not delay urgent medical carefor the victim.

Offsite Response Organizations (ORO) should demonstrate the capability to transport contaminated injured indi viduals to. medical facilities.., An ambulance should be used for the response to the victim. However, to. avoid taking an ambulance out of service for an extended time, any vehicle (e.g., car, truck, or van) may be utilized to transport the victim to the medical facility. Normal communications between the ambulance/dispatcher and the receiving medical facility should be demonstrated. If a substitute vehicle is used for transport to the medical facility, this communication must occur prior to releasing the ambulance from the drill. This communication would include reporting radiation-monitoring results, if available. Additionally, the ambulance crew should demonstrate, by interview, knowledge of where the ambulance and crew would be monitored and decontaminated, if required, or whom to contact for such information.

Monitoring of the victim may be performed prior to transport, done enroute, or deferred to the medical facility. Prior to using a monitoring instrument(s), the monitor(s) should demonstrate the process of checking the instrument(s) for proper operation. All monitoring activities should be completed, as they would be in an actual emergency. Appropriate contamination control measures should be demonstrated prior to and during transport and at the receiving medical facility.

The medical facility should demonstrate the capability to activate and set up a radiological emergency area for treatment. Equipment and supplies should be available for the treatment of contaminated injured individuals.

173

Unclassified Radiological Emergency Preparedness Program (REP)

After Action Report/Improvement Plan Three Mile Island Nuclear Generating Station The medical facility should demonstrate the capability to make decisions on the need for decontamination of the individual, to follow appropriate decontamination procedures, and to maintain records of all survey measurements and samples taken. All procedures for the collection and analysis of samples and the decontamination of the individual should be demonstrated or described to the evaluator.

All activities associated with this criterion must be based on the ORO's plans and procedures and completed, as they would be in an actual emergency, unless noted above or otherwise indicated in the extent of play agreement.

Note: This sub-element was federally evaluated at Hanover General Hospital (York' County), June 5'h, 2009.

174 a

Unclassified Radiological Emergency Preparedness Program (REP)

After Action Report/Improvement Plan Three Mile Island Nuclear Generating Station American Red Cross risk and support county chapters:

Lebanon County Chapter 1220 Mifflin Street Lebanon, PA 17046 Karen Clemens (717) 273-2671 ARC of the Susquehanna Valley 1804 N. Sixth Street-P.O. Box 5740 Harrisburg, PA 17110 Chris Weidenhammer (717) 234-3101 Cumberland County Chapter 79 E. Pomfret Street Carlisle, PA 17013 Thomas Reardon (717) 243-5211 Franklin County Chapter 25 Penncraft Avenue Chambersburg, PA 17201 Thomas Reardon (717) 264-6214 Schuylkill and Eastern Northumberland County Chapter 1402 Laurel Boulevard Pottsville, PA 17901 Janet Curtis (570) 622-9550 York County Chapter 724 South George Street York, PA 17403 Robert Straw (717) 845-2751 Adams County Chapter Office Number 717-334-1814 (Combined with York County) 175

a Unclassified Radiological Emergency Preparedness Program (REP)

Three Mile Island Nuclear Generating Station After Action Report/Improvement Plim a.

ATTACHMENT A Three'Mile Island Nuclear Generating Station 2011 Extent of Play Demonstration Tables PLUME PHASE EXERCISE -

A. Activities-April 12, 2011

1. Risk Public School Districts with schools located within the EPZ and those districts situated outside the EPZ, but with students living within the EPZ, will participate and be evaluated by the Department of Homeland Security. Each identified District Administration Office will be evaluated. When a school system is comprised of multiple buildings (High School, Middle School, Elementary School),

the affected buildings (those with students from the EPZ) will be evaluated on a rotational basis to coincide with the six-year exercise cycle.

Time: Out of Sequence - 9:00 - 11:00 AM COUNTY SCHOOL DISTRICT SCHOOL Dauphin Central Dauphin

1. CD East HS
2. Swatara Middle School
3. Tri Community Elem. School Derry Township
1. Hershey Intermediate Elem.
2. Hershey Middle School Harrisburg
1. Harrisburg HS
2. Scott School
3. Shimmell School
4. CAIU Capital AS for the Arts Lower Dauphin
1. Lower Dauphin HS
2. Price Building
3. South Hanover Elem.

Middletown Area

1. Middletown Area HS Milton Hershey
1. Milton Hershey School Steelton-Highspire 1.Steelton-Highspire HS Lancaster.

Donegal 1.Donegal HS 2.Donegal Springs ES Elizabethtown Area

1. Mill Road ES
2. East High Street Elem
3. Fairview ES Lebanon Palmyra Area 1.Palmyra HS 176 a

6 a

Unclassified Radiological Emergency Preparedness Program (REP)

Three Mile Island Nuclear Generating Station After Action Report/Improvement Plan York Central York

1. Central York MS
2. Hayshire Elem.

___3.

Roundtown ES Northeastern

1. Northeastern MS
2. Spring Forge Intermediate
3. Shallow Brook Intermediate
4. York Haven ES Dover Area
1. Dover Intermediate School Eastern
1. Kreutz Creek Elem.

West Shore

11. Cedar Cliff HS
2. New Cumberland MS
3. Allen MS
4. Highland Elem
5. Red Mill ES 177

4 Unclassified Radiological Emergency Preparedness Program (REP)

Three Mile Island Nuclear Generating Station After Action Report/Improvement Plan

2. County Emergency Operations Centers (EOCs)

Time: Per Scenario DEMONSTRATION FOR EOC MOBILIZATION FOR COUNTIES (Plume Phase Exercise)

COUNTY DATE Time Adams April 12,2011 Per Scenario Cumberland April 12,2011 Per Scenario Dauphin April 12,2011 Per Scenario Franklin*

April 12,2011 Per Scenario Lancaster Participate/Not Evaluated Per Scenario Lebanon April 12,2011 Per Scenario York April 12,2011 Per Scenario Schuylkill April 12,2011 Per Scenario

  • Note that Franklin County EOC is a new location 4

4 178 4

Unclassified Radiological Emergency Preparedness Program (REP)

Three Mile Island Nuclear Generating Station After Action Report/Improvement Plan

3. Municipal Emergency Operations Centers (EOC)

Time: Per Scenario Note: Bold is federally evaluated, No Bold is Participating DEMONSTRATION FOR EOC MOBILIZATION FOR MUNICIPALITIES. (Plume Phase Exercise)

RISK COUNTY MUNICIPALITY DATE Cumberland New Cumberland Borough April 12,2011 Lower Allen Township,

April 12,2011 Dauphin Conewago Township April 12,2011 Derry Township April 12,2011 Harrisburg City' April 12,2011 Highspire Borough April 12,2011 Hummelstown Borough:

April 12,2011 Londonderry Township April 12,2011 Lower Paxton Township April 12,2011 Lower Swatara Township April 12,2011

  • Middletown/Royalton Boroughs April 12,2011 Paxtang Borough April 12,2011 South Hanover Township April 12,2011 Steelton Borough April 12,2011 Swatara Township April 12,2011 Lancaster
    • Conoy Township April 12,2011 East Donegal Township April 12,2011
  • Elizabethtown Borough/West April 12,2011 Donegal Township/Mount Joy Township Lebanon South Londonderry Township April 12,2011 York Conewago Township April 12,2011 Dover Township April 12,2011 Fairview Township April 12,2011 Goldsboro Borough April 12,2011 Hellam Township April 12,2011
  • Lewisberry Borough/Newberry April 12,2011 Township Manchester Township April 12,2011
  • Northeast Area (Mt. Wolf/E.

April 12,2011 Manchester/ Manchester)

Springettsbury Township April 12,2011 Warrington Township April 12,2011 York Haven Borough April 12,2011

    • A FEMA evaluator will be available to rlffmonstrate an ARCA (See Attachment B).

a Unclassified Radiological Emergency Preparedness Program (REP)

Three Mile Island Nuclear Generating Station After Action Report/Improvement Plan

4.

One back-up one route alerting demonstration by one municipality in each risk county.

(During Scenario Exercise)

Cumberland New Cumberland Borough April 12,2011 Dauphin Highspire Borough April 12,2011 Lancaster East Donegal Township April 12,2011 Lebanon South Londonderry Township April 12,2011 York Newberry Township April 12,2011 a

5. Traffic and Access Control Points
a. The Pennsylvania State Police will brief at the PSP Harrisburg Barracks, 8000 Bretz Drive, Harrisburg, PA, 17112. Those attending the briefing will not actually deploy to the TCP/ACPs.
b. The PSP briefing will be performed out of sequence in a demonstration window of 10:00 a.m. to 12:00 noon on April 13, 2011.
c. Each municipal/regional police force with a TCP assigned in its plan will demonstrate all preparation duties including TCP responsibilities and radiological briefing. Dispatch of persons to the TCP site will not occur during the exercise.
d.

Municipal and county staffs will be prepared to brief the FEMA evaluator on actions to be taken should there be an impediment to evacuation on a designated route. This will be demonstrated between 7:00 pm - 9:30 pm on April 12, 2011.

a Municipal / Regional Police Forces Cumberland New Cumberland Borough Dauphin None Lancaster Elizabethtown Borough PD Susquehanna Regional PD Lebanon South Londonderry Township York None 180 a

Unclassified Radiological Emergency Preparedness Program (REP)

Three Mile Island Nuclear Generating Station After Action Report/Improvement Plan B. April 12,2011

1. Reception Centers (Out of Sequence)

DEMONSTRATION of Reception Centers COUNTY DATE Time Adams April 13,2011 7:00 p.m. - 9:30 p.m.

Cumberland April 13, 201.1 7:00 p.m. - 9:30 p.m.

Dauphin April 13, 2011 7:00 p.m. - 9:30 p.m.

Franklin April 13, 2011 7:00 p.m. - 9:30 p.m.

Lancaster April 13,2011 7:00 p.m. - 9:30 p.m.

Lebanon April 13, 2011 7:00 p.m. - 9:30 p.m.

Schuylkill April 13,2011 7:00 p.m. - 9:30 p.m.

York April 13, 2011 7:00 p.m. - 9:30 p.m.

COUNTY Reception Center Location Adams Not' Evaluated Cumberland

'Big Spring HS Dauphin None Franklin Faust Jr. High School Lancaster Park City Mall Lebanon Lebanon County Career and Tech Center Eastern Lebanon County HS and MS Schuylkill Blue Mountain HS York Southern School Complex 181

6 Unclassified Radiological Emergency Preparedness Program (REP)

Three Mile Island Nuclear Generating Station After Action Report/Improvement Plan

2. Monitoring/Decontamination Centers (Out of Sequence)

COUNTY DEMONSTRATION of Mon/Decon Centers DATE Time Adams April 13,2011 7:00 p.m. - 9:30 p.m.

Cumberland April 13,2011 7:00 p.m. - 9:30 p.m.

Dauphin April 13,2011 7:00 p.m. - 9:30 p.m.

Franklin April 13,2011 7:00 p.m. - 9:30 p.m.

Lancaster April 13, 2011 7:00 p.m. - 9:30 p.m.

Lebanon April 13, 2011 7:00 p.m. -9:30 p.m.

Schuylkill April 13,2011 7:00 p.m. - 9:30 p.m.

York April 13, 2011 7:00 p.m. - 9:30 p.m.

COUNTY Mon/Decon Center Locations Quantity Adams Not Evaluated 0

Cumberland Big Spring HS 1

Dauphin None

  • 0 Franklin
  • Faust Jr. High School 1

Lancaster Manheim Township Complex 1

Lebanon Lebanon County Career and Tech Center 1

Schuylkill Blue Mountain HS 1

York Southern School Complex 1

  • Note that Faust Jr. High School has not been previously evaluated. Due to schedule conflicts the interior of the school is unavailable except for evaluator walkthrough. The county will demonstrate their backup/overflow plan in the parking lot of the facility.

a 4

182 4

Unclassified Radiological Emergency Preparedness Program.(REP)

Three Mile Island Nuclear Generating Station After Action Report/Improvement Plan

3. Mass Care Centers (Out of Sequence)

COUNTY DEMONSTRATION of Mass Care Centers.

DATE Time Adams April 13,2011 7:00 p.m. - 9:30 p.m.

Cumberland April 13, 2011 7:00 p.m. - 9:30 p.m.

Dauphin April 13, 2011 7:00 p.m. - 9:30p.m.

Franklin April 13, 2011 7:00 p.m.- 9:30 p.m.

Lancaster April 13,2011 7:00 p.m. - 9:30 p.m.

Lancaster Walk April 13,2011 1:00 p.m. - 4:00 p.m.

Through:-

Lebanon April 13, 2011 7:00 p.m. - 9:30 p.m.

Schuylkill April 13, 2011 7:00 p.m. - 9:30 p.m.

York April 13, 2011 7:00 p.m. - 9:30 p.m.

Note: Bold is Evaluated in the evening, No Bold is evaluated by walk through in the afternoon.

COUNTY Mass Care Center Locations

_Quantity Adams Not Evaluated 0

Cumberland

.*Big Spring HS 1

Dauphin Halifax Area HS 2

Lenkerville Elem. School Franklin Faust Jr. High School 1

Lancaster

  • Manheim Township MS 1

Lancaster Walk Manheim Township HS 7

Through - Out Warwick HS of Sequence Warwick MS Cocalico HS Cocalico MS Conestoga Valley HS Conestoga Valley MS Lebanon Northern Lebanon HS 1

Schuylkill Blue Mountain HS 1

York Southern School Complex 1

  • Note that the county will be exercising an unevaluated animal care component during the exercise.

183

6 Unclassified Radiological Emergency Preparedness Program (REP)

Three Mile Island Nuclear Generating Station After Action Report/Improvement Plan

4. Emergency Worker Monitoring / Decontamination Stations (Out of Sequence)

Time: 7:00- 9:30 PM Cumberland

  • West Shore Bureau Fire Station #2 Lemoyne April 13, 2011 Dauphin Harrisburg Area Community College April 13, 2011 Lancaster FD Mount Joy April 13, 2011 Lebanon Annville Union Hose Fire Company April 13, 2011 Fredricksburg Fire Company York Monaghan Twp. Fire Co April 13, 2011
  • This location is utilizing an alternate layout. The normal layout will be visible for evaluator review but is unavailable for setup in this exercise.

4 II.

POST PLUME EXERCISE Not Applicable for this Exercise. The Post-Plume Exercise was last conducted in conjunction with the Limerick 2010 Post Plume Exercise ATTACHMENT B PREVIOUS ISSUES COUNTY ARCA FACILITY EVALUATED NUMBER Lancaster 64-09-3.a.1A-03 Conoy Township backup route alerting team members were receiving a radiological brief and being issued dosimetry when the notification of a failed siren was received at the Conoy Emergency Operations Center, delaying the start of their runs for 15 minutes.

4 184 4

Unclassified Radiological Emergency Preparedness Program (REP)

Three Mile Island Nuclear Generating Station After Action Report/Improvement Plan This page is intentionally blank.

185