Inspection / Activity Plan Page 1 of 2 03/04/2011 07:04:23 Report 22 03/01/2011 - 06/30/2012 Unit Number Planned Dates Start End Inspection Activity Title No. of Staff on Site Crystal River SGRP

- SGRP ACTIVITIES 2

3 IP Steam Generator Replacement Inspection 50001 03/01/2011 04/01/2011 TFPI

- 805 TFPI 6

3 IP Fire Protection-NFPA 805 Transition Period [Triennial]

7111105P 04/04/2011 04/08/2011 3

IP Fire Protection-NFPA 805 Transition Period [Triennial]

7111105P 04/18/2011 04/22/2011 PSB1-RP

- RAD ENVIRONMENTAL MONITORING PROGRAM 1

3 IP Radioactive Gaseous and Liquid Effluent Treatment 71124.06 06/13/2011 06/17/2011 EB3-HS

- HEAT SINK 1

3 IP Heat Sink Performance 7111107T 06/20/2011 06/24/2011 OL EXAM

- INIITIAL EXAM PREP 5

3 CRYSTAL RIVER/SEPTEMBER 2011 EXAM AT POWER FACILITIES V23355 08/22/2011 08/26/2011 OL EXAM

- INIITIAL EXAM - WEEK 1 5

3 CRYSTAL RIVER/SEPTEMBER 2011 EXAM AT POWER FACILITIES V23355 09/12/2011 09/16/2011 PSB1EP

- EMERGENCY PREPAREDNESS INSPECTION 1

3 IP Alert and Notification System Testing 7111402 09/12/2011 09/16/2011 3

IP Emergency Preparedness Organization Staffing and Augmentation System 7111403 09/12/2011 09/16/2011 3

IP Emergency Action Level and Emergency Plan Changes 7111404 09/12/2011 09/16/2011 3

IP Correction of Emergency Preparedness Weaknesses and Deficiencies 7111405 09/12/2011 09/16/2011 3

IP Performance Indicator Verification 71151 09/12/2011 09/16/2011 OL EXAM

- INITIAL EXAM - WEEK 2 4

3 CRYSTAL RIVER/SEPTEMBER 2011 EXAM AT POWER FACILITIES V23355 09/19/2011 09/23/2011 PSB1-RP

- RP OCCUPATIONAL WEEK 1 4

3 IP Radiological Hazard Assessment and Exposure Controls 71124.01 10/31/2011 11/04/2011 3

IP Occupational ALARA Planning and Controls 71124.02 10/31/2011 11/04/2011 3

IP In-Plant Airborne Radioactivity Control and Mitigation 71124.03 10/31/2011 11/04/2011 3

IP Occupational Dose Assessment 71124.04 10/31/2011 11/04/2011 3

IP Radiation Monitoring Instrumentation 71124.05 10/31/2011 11/04/2011 3

IP Performance Indicator Verification 71151 10/31/2011 11/04/2011 PSB1-RP

- RP OCCUPATIONAL WEEK 2 4

3 IP Radiological Hazard Assessment and Exposure Controls 71124.01 11/14/2011 11/18/2011 3

IP Occupational ALARA Planning and Controls 71124.02 11/14/2011 11/18/2011 3

IP In-Plant Airborne Radioactivity Control and Mitigation 71124.03 11/14/2011 11/18/2011 3

IP Occupational Dose Assessment 71124.04 11/14/2011 11/18/2011 3

IP Radiation Monitoring Instrumentation 71124.05 11/14/2011 11/18/2011 3

IP Performance Indicator Verification 71151 11/14/2011 11/18/2011 This report does not include INPO and OUTAGE activities.

This report shows only on-site and announced inspection procedures.

Inspection / Activity Plan Page 2 of 2 03/04/2011 07:04:23 Report 22 03/01/2011 - 06/30/2012 Unit Number Planned Dates Start End Inspection Activity Title No. of Staff on Site Crystal River PI&R

- PROBLEM IDENTIFICATION AND RESOLUTION 5

3 IP Identification and Resolution of Problems 71152B 01/17/2012 01/20/2012 3

IP Identification and Resolution of Problems 71152B 01/30/2012 02/03/2012 MOD

- MODIFICATION INSPECTION 3

3 IP Evaluations of Changes, Tests, or Experiments and Permanent Plant Modifications 7111117T 04/16/2012 04/20/2012 3

IP Evaluations of Changes, Tests, or Experiments and Permanent Plant Modifications 7111117T 04/30/2012 05/04/2012 ISFSI

- ISFSI PAD CONCRETE POUR 2

3 IP On-Site Fabrication Of Components And Construction On An ISFSI 60853 06/18/2012 06/22/2012 PSB1EP

- EMERGENCY PREPAREDNESS EXERCISE 3

3 IP Exercise Evaluation 7111401 06/25/2012 06/29/2012 3

IP Emergency Action Level and Emergency Plan Changes 7111404 06/25/2012 06/29/2012 3

IP Performance Indicator Verification 71151 06/25/2012 06/29/2012 This report does not include INPO and OUTAGE activities.

This report shows only on-site and announced inspection procedures.