PSEG NUCLEAR LLC - EP 9.1 Rev. 21 SECTION 9 EMERGENCY FACILITIES AND EQUIPMENT 1.0 PSEG Nuclear LLC - Emergency Facilities and Equipment Emergency facilities and equipment are maintained for the PSEG Nuclear LLC both on and offsite. Equipment specifically for monitoring and assessment of operational, radiological, geophysical events, and similar instrumentation is described in Section 10, Accident Assessment. The Emergency Operations Facility and Emergency News Center are offsite facilities that serve the PSEG Nuclear LLC.

Although onsite facilities are described separately in paragraph Sections 2.0 and 3.0, to reflect station specifics, they have common functions, and fulfill the same organizational and operational commitments.

1.1 Control Rooms Control Rooms continue their control functions during emergency response.

Additional classification and notification responsibilities are met from the control room until other emergency facilities are activated. The radiological protection emergency equipment and communications support that are available to each control room are shown in Tables 9-1 and 7-1. The specific features of major communications systems are described in Section 7, Emergency Communications.

1.2 Operations Support Centers Operations Support Centers (OSC) function as information relay stations, dispatching offices, assembly and assignment points, and also as accountability stations for teams assigned from the OSC. Radiological protection emergency equipment and communication systems that are available to the OSC are presented in Table 9-1 and Table 7-1, respectively. Specific features of the communications systems are described in Section 7, Emergency Communications.

1.3 Technical Support Centers The Technical Support Centers (TSCs) also have common functions and similar equipment and support. The TSC provides a well equipped location onsite to support plant management during an emergency. The TSC functions as an augmented communication/analysis center of technical data to supplement the Control Room staff's technical analysis and to support plant operations personnel.

PSEG NUCLEAR LLC - EP 9.2 Rev. 21 The TSC is used by members of the emergency response organization to relieve control room operators of (and remove from the control room) any plant specific duties not directly related to the direct handling of plant controls. Such duties include directing analysis and assessment of the emergency conditions and performing functions associated with the Emergency Operations Facility, when that is not activated.

The TSC is activated for Alert, Site Area Emergency, or General Emergency action levels. The TSC is used as the assembly point for utility personnel, onsite vendor support, NRC, or for the personnel who are directly involved in assessment of an accident and mitigation.

The TSC emergency response facility can be staffed and activated within 90 minutes of an Alert or higher emergency classification. This staffing and activation time could vary if severe weather conditions or acts of nature/terrorism were experienced at the same time as the ERO callout.

The Emergency Duty Officer (EDO) determines when the TSC is staffed based on requirements identified in the PSEG Nuclear LLC Emergency Organization Chart.

The EDO's discretion may be used to declare the TSC activated with less than the staffing required in the organization chart based on extenuating circumstances and plant conditions. Efforts to staff all required positions shall continue until the positions are filled or the emergency is terminated.

Radiological protection emergency equipment and communications support that are available to the TSC are presented in Table 9-1 and Table 7-1, respectively. The specific features of the communications systems are described in Section 7, Emergency Communications.

1.4 Emergency Vehicles An ambulance is available to transport injured or contaminated-injured personnel to Memorial Hospital of Salem County or another facility.

2.0 Onsite Emergency Facilities and Equipment - Salem Emergency facilities and equipment were developed to meet the intent of NUREG-0737, Supplement 1, except as indicated.

2.1 Control Room Area The Salem Control Rooms have been designed to meet the habitability requirements of the General Design Criteria 19 and Standard Review Plan Section 6.4. The radiological protection emergency equipment provided in the Control Rooms and Operations Support Center is shown in Table 9-1.

PSEG NUCLEAR LLC - EP 9.3 Rev. 21 2.2 Operations Support Center (OSC)

The Salem Operations Support Center (OSC) is located in the Operations conference room adjacent to the Control Room. In the event of an emergency, operations personnel not on duty and other support personnel report to the OSC to form repair and corrective action teams. Additionally, an OSC Coordinator is designated to coordinate the teams' efforts. The Salem TSC will serve as a backup OSC if required.

2.3 Technical Support Center (TSC)

The Salem Technical Support Center (TSC) is located on the third floor of the Clean Facilities (B) Building isolated from the containment building. The TSC meets all habitability requirements outlined in NUREG-0737, Supplement 1. This center supplies technical support to the operations personnel in the Control Room area.

The analytical and assessment capabilities assigned to the Salem TSC include:

Safety Parameter Display System (SPDS)

Computerized Dose Assessment Plant Engineering Support Documentation available within the TSC supports emergency classification, procedures, and assessments. Document groups include:

Emergency Plans and Procedures Operating Procedures (Emergency and Normal)

Departmental Support Documents Technical Specifications Engineering Support Material Updated Final Safety Analysis Report Technical Drawings The Salem TSC is in proximity to the Technical Document Room (TDR), and has the capability to retrieve plant-specific documents or drawing groups as well as applicable codes, standards, and regulations utilizing the Document Control Records Management System (DCRMS). TDR has DCRMS work stations and printer available for use. The TSC Ventilation System services the TDR. The TSC is convenient to other support facilities within the B Building. Detailed information on the TSC can be obtained by reviewing the "Salem TSC Configuration Baseline Documentation"

[DE-CB.BBD-0012 (Z)].

PSEG NUCLEAR LLC - EP 9.4 Rev. 21 2.4 Control Point (CP)

During normal operations, this area serves Salem as the access control point for personnel entering or leaving the Radiological Controlled Area. The radiological protection emergency equipment provided at this location is shown in Table 9-1.

Communications equipment is described in Section 7, Emergency Communications.

3.0 Onsite Emergency Facilities and Equipment - Hope Creek Emergency facilities and equipment were developed to meet the intent of NUREG-0737, Supplement 1, except as indicated.

3.1 Control Room Area The HCGS Control Room (CR) areas have been designed to meet the applicable habitability requirements. Typical radiological protection emergency equipment in the Control Room area and Operations Support Center (OSC) is shown in Table 9-1.

3.2 Operations Support Center (OSC)

The Hope Creek Operations Support Center (OSC) is located in the Outage Control Center adjacent to the Control Room. In the event of an emergency, operations personnel not on duty and other support personnel report to the OSC to form repair and corrective action teams. Additionally, an OSC Coordinator is designated to coordinate the teams' efforts. The office space above the Hope Creek TSC will serve as a back up OSC, if required.

3.3 Technical Support Center (TSC)

The Hope Creek TSC is located on Elevation 132' in the reactor building, but isolated and shielded from the rest of the reactor building. The TSC meets all habitability requirements outlined in NUREG-0737, Supplement 1.

The analytical and assessment capabilities assigned to the TSC include:

Radiological Monitoring System (RMS)

Control Room Integrated Display System (CRIDS)

Safety Parameter Display System (SPDS)

Computerized Dose Assessment Plant Engineering Support

PSEG NUCLEAR LLC - EP 9.5 Rev. 21 Documentation available within the TSC assists in a variety of analyses and assessments. Document groups include:

Emergency Plan Implementing Procedures.

Normal Operating Procedures.

(Emergency) Abnormal Operating Procedures.

Plant Technical Specifications.

Updated Final Safety Analysis Report.

Selected Vendor Manuals.

Technical Drawings.

Additional documentation is immediately available in the Technical Document Room.

The TSC is located within the protected area convenient to the Control Room, Operations Support Center and Control Point and is a dedicated emergency response Facility. Access is controlled through single entry access. Other entries and exits are maintained locked.

Habitability is controlled to meet the same habitability standards as required in the Control Room. The heating, ventilating, and air conditioning (HVAC) systems include the use of high efficiency particulate absorber (HEPA) and charcoal filtration, which prolongs habitability should in-plant conditions degrade.

Sufficient monitoring and protective equipment is kept in a secured area, the Radiation Protection Locker, of the TSC and available to the TSC staff.

3.4 Control Point (CP)

During normal operation, this area is located at the 137' elevation and serves as the regular Access Control Point for personnel entering or leaving the Radiological Controlled Area. Radiological protection emergency equipment is provided at the Control Point and is listed in Table 9-1.

4.0 Offsite Emergency Facilities and Equipment 4.1 Emergency Operations Facility - General Description The Emergency Operations Facility (EOF) is controlled and operated by PSEG Nuclear LLC. It serves as the near site support center to form management of the aggregate response to a radiological emergency as defined by NUREG-0654, Revision 1, and Appendix 1. PSEG NUCLEAR commits to operating the EOF so as to fulfill the functional requirements of paragraph 4.1 of NUREG0737, Supplement 1. It should be noted that based on the backup EOF exemption granted for the Salem Generation Station Plan, and the fact that the location of Salem and Hope Creek Generating Stations is treated as a single site; the exemption is applicable to all EOF requirements for Salem and Hope Creek Generating Stations.

PSEG NUCLEAR LLC - EP 9.6 Rev. 21 The EOF provides facilities and equipment to support staff performance of four major functions:

1.

Management of overall emergency response activities.

2.

Coordination of radiological and environmental assessment.

3.

Development of recommendations for protective actions for the public.

4.

Coordination of emergency response operations with Federal, state, and local agencies in accordance with the Emergency Plan.

The communications systems available at the EOF are presented in Table 7-1.

Specific features of those systems are described in Section 7, Emergency Communications.

The EOF emergency response facility can be staffed and activated or ready to activate, within 90 minutes of an Alert or higher emergency classification. This staffing and activation time could vary if severe weather conditions or acts of nature/terrorism were experienced at the same time as the ERO callout.

Activation of the Emergency Operations Facility is at the option of PSEG Nuclear LLC at the Alert emergency classification. The option is exercised depending upon management's evaluation of the potential consequences of the situation based upon the nature of initiating conditions, trends subsequently perceived, and results of actions taken to mitigate potential consequences. EOF activation is mandatory in the event of declaration of a Site Area Emergency or General Emergency.

An individual who is designated as the Emergency Response Manager (ERM) manages the activated EOF. The ERM directs PSEG Nuclear LLC's offsite response activities and coordinates actions with and provides appropriate support to the Technical Support Center (Emergency Duty Officer). The EOF is staffed by PSEG Nuclear LLC and other (Federal, state, and support personnel, as required) emergency personnel designated by the PSEG Nuclear LLC Emergency Plan.

The ERM determines when the EOF is fully staffed based on manning requirements as identified in the PSEG Nuclear LLC Emergency Organization Chart. The ERM's discretion may be used to declare the EOF activated with less than the staffing required in the organization chart based on extenuating circumstances and plant conditions. Efforts to staff all required positions shall continue until the positions are filled or the emergency is terminated.

Equipment is provided in the EOF for acquisition, recording, display and evaluation of containment and operational conditions, radiological releases, and meteorological data. The data is analyzed and evaluated to determine the nature and scope of any protective measures, which may be recommended to state and local officials for protection of the public health and safety, if the magnitude and potential effects of a radioactive release dictate. The equipment includes a display of information collected by the Radiological Monitoring System (RMS). All equipment, displays, and instrumentation to be used to perform essential EOF functions are located in the EOF.

PSEG NUCLEAR LLC - EP 9.7 Rev. 21 Facilities are provided in the EOF for NRC, FEMA, New Jersey, Delaware and local emergency response agency personnel responsible for implementing emergency response actions for protection of the general public. This arrangement enhances coordination of activities and exchange of information among participating agencies and the PSEG Nuclear LLC emergency response organization. The agencies also operate from other offsite control centers located at their respective agency facilities.

To ensure EOF activation readiness, PSEG Nuclear LLC provides normal industrial security for the EOF complex including lock and key control, a personnel identification system, exterior lighting, and a perimeter (building) security system providing offsite alarm notification and response by local police department. If the EOF is activated, access to the building and facility is restricted to authorized personnel by the industrial security system.

4.2 Location, Structure, and Habitability The Emergency Operations Facility is located in PSEG Nuclear LLC Environmental &

Energy Resource Center (EERC) on Chestnut Street in Salem, New Jersey. This site is located 7.5 miles from the Technical Support Center. The site location is judged to provide operational and logistical benefits with regard to its relationship to the areas transportation system. Salem is at the intersection of the two state highways (Routes 45 and 49). Three county highways, Routes 557, 540, and 581, connect to Routes 45 and 49. A freight only railroad and an airfield serve the city of Salem capable of accommodating small commercial aircraft. In addition, the offsite EERC has a helicopter-landing pad. There is also a landing pad located just outside of the Protected Area. This makes possible rapid movement of personnel between the station and the EOF.

This transportation network makes the EOF readily accessible by road and air to designated personnel of all agencies and activities assigned an emergency response role by the emergency plan.

The physical structure of the facility has been well engineered for the design life of the plant. The building is a 65,000 square foot structure on reinforced concrete footings and floor slab, with supporting steel columns, beams, and joists. The built up roofing material is supported on a steel deck.

The EOF conforms to all applicable building codes and has been designed to withstand winds and floods with 100 year recurrence frequency. The State of New Jersey Department of Environmental Protection identifies the 10 year and 100 year high water levels at the EOF site as 7.1 feet and 8.9 feet above mean sea level, respectively. The floor elevation of the EOF is 9.0 feet. The elevation of the road to the EOF is slightly over 4 feet. Thus, record high water levels would flood the access road and preclude access to the EOF by vehicle and could hamper activities of mobile monitoring teams in some areas. The EOF would continue to be accessible by helicopter. Internal EOF operations would continue without adverse impact.

PSEG NUCLEAR LLC - EP 9.8 Rev. 21 The SGS Final Safety Analysis Report, Environmental Report, Operating License Stage, Appendix B Report, Site environmental studies, identifies high winds with a 100 year recurrence frequency as having a maximum velocity of 100 miles per hour. It is not anticipated that such winds will significantly affect self contained internal EOF operations. This is due to the strength of building construction and the availability of backup power.

However, activities of mobile monitoring teams would have to be suspended. Under such conditions, radiation exposures would be correspondingly low. Remote monitoring would continue to be available to the extent transmission lines survive.

Similarly, data transmission could be adversely impacted by damage to microwave and radio antennae and transmission lines, particularly if winds were accompanied by electrical storms, which are often associated with squall lines, tornadoes and hurricanes. Under such circumstances, atmospheric conditions could be expected to intermittently affect data transmission and communications.

Protective clothing is maintained at the EOF, in accordance with the emergency plan.

In addition, mutual support agreements with other utilities in the region include providing emergency equipment, including radiation survey devices and protective clothing. Potassium iodide for the staff is also stored in the EOF emergency equipment locker.

Additional supplies are available from Radiation Management Corporation, Philadelphia, Pennsylvania or other approved vendors. A description of the methodology to determine airborne I-131 concentrations is presented in Section 10 of the Emergency Plan. Detection limits for I-131 are less than 1E-7 uci/cc if not masked by noble gases. Masking is not expected to be a factor due to use of silver zeolite filter cartridges and adequate purge times in sample collections.

Full face respirators with charcoal filters are maintained in the EOF. However, airborne contamination is not expected to present a major problem at the EOF due to its location and the upgraded ventilation system.

4.3 Size The EOF meets or exceeds the space requirements of paragraph 8.4.1c of NUREG-0737, Supplement 1. Approximately 5240 square feet of floor space in the Nuclear Training Center is designated for use as the Emergency Operations Facility.

This provides more than 75 square feet of workspace per person for a staff of up to 70 persons and 650 square feet for conference rooms.

Additional space is available in the building to accommodate another 100 persons in the unlikely event of a situation in which a greatly augmented staff would be required.

Normal EOF occupancy by all concerned parties and agencies is not expected to exceed 80 persons.

PSEG NUCLEAR LLC - EP 9.9 Rev. 21 The functional layout of the EOF depicts designated workspaces:

1.

Space for EOF data system equipment for data transmission and reception (Data Center, Communications Center).

2.

Space to repair, maintain and service equipment displays and instrumentation (in Nuclear Training Center workshops and labs).

3.

Space to accommodate communications equipment and its use by EOF personnel to perform their assigned functions.

4.

Space for ready access to functional displays of EOF data (Data Center, provisions for installation of remote terminal in the Dose Assessment Area).

5.

Space for storage of plant records and historical data or space for the means to readily acquire and display the records.

6.

Space for emergency response activities.

7.

Office space for state, local and FEMA personnel.

8.

Separate office space to accommodate a minimum of ten NRC personnel during emergency activation of the EOF (NRC offices).

Personnel are assigned to work areas in functional groups. Groups, which perform related tasks and therefore would have the most need for face to face interaction, are, in most cases, located adjacent to one another. Each workstation is assigned sufficient display space, equipped and staffed as appropriate to its function.

4.4 Radiological Monitoring The EOF complies with the radiation protection provisions of paragraph 8.4.1B of NUREG-0737, Supplement 1 by providing radiological monitoring equipment in the facility. This equipment provides the capability to monitor airborne radioactivity (gross beta, gamma, iodine, and particulates) to ensure that EOF personnel are not subjected to adverse radiological conditions. Available equipment and a table in a Emergency Plan Implementing Procedure permits the detection of radioiodines at a concentration as low as 1.00E-07 uCi/cc using a field counting methodology (A portable continuous air sampler collects iodine in a silver zeolite cartridge. The cartridge is then counted using a count rate meter. The corrected counts per minute value are then compared to a graph to find the iodine concentration).

The continuous air monitor sampler may be moved to various points in the facility, is equipped with a strip chart recorder, an alarm light, and an alarm bell. The alarm setting is variable and will be set slightly above background to give an early warning of adverse conditions, which may affect EOF habitability. In addition, the alarm light provides visual warning of radiation levels. The air sampler is maintained and calibrated on a regular schedule by station personnel.

More detailed counting analysis is available at the station (emergency situation permitting) or any other licensed facility (i.e. Peach Bottom, Limerick, etc.).

PSEG NUCLEAR LLC - EP 9.10 Rev. 21 Survey meters are available, which have sensitivity ranges up to 50 R/hr. Additional EOF radiation monitoring equipment includes high and low range self reading dosimeters (or equivalent electronic dosimeters), TLDs, and air samplers. Radiation monitoring equipment is stored in the radiological protection emergency equipment closet (Table 9-1). The radiological assessment staff performs habitability of the EOF, in accordance with procedure.

The Radiological Support Managers have a variety of radiological, health physics, and nuclear power plant experience.

4.5 Instrumentation, Data System Equipment, and Power Supplies The EOF complies with the provisions of paragraph 8.4 1G NUREG-0737, Supplement 1 by providing an EOF data system consisting of a Radiological Monitoring System, an operational parameter data information system, which provides plant variables to a computer system that displays data and is capable of being printed out.

The EOF data system performs its functions independently of personnel actions in the Control Room and the TSC and will not degrade or interfere with Control Room and plant functions.

Backup power is provided to ensure data system availability. Backup power is supplied by a diesel generator in conjunction with an automatic transfer switch, which activates the generator upon loss of power. The generator provides electrical output sufficient to supply all facility lighting, the telephone system and all EOF data and communications systems described in this document. Electrical equipment load in the EOF does not affect any safety related power source. The data system has been designed to preclude loss of any stored data vital to EOF functions due to power supply failure or circuit transient.

4.6 Technical Data and Data System The comprehensive EOF technical data system is capable of reliable collection, storage, analysis, display, and communication of information on containment conditions, radiological releases, and meteorology sufficient to determine site and regional status, determine changes in status, forecast status and take appropriate actions. Variables from the following categories that are essential to EOF functions are available in the EOF.

Appropriate variables from Table 1 of Regulatory Guide 1.97 (Rev. 2) and; the meteorological variables in Regulatory Guide 1.97 (Rev. 2) for site vicinity and regional data available via communication from the National Weather Service.

PSEG NUCLEAR LLC - EP 9.11 Rev. 21 5.0 Emergency News Center/Joint Information Center (ENC/JIC)

Emergency News Center/Joint Information Center (ENC/JIC) facilities are at the Salem County 911 Center. The ENC/JIC provides space for media briefings; media work area, and telephone access. Separate work areas are maintained for PSEG Nuclear LLC, NRC, State and County personnel. The facility is convenient to major highways. Designed for public use, the building has sufficient facilities to support use by 100 or more media personnel.

If support for more then 100 media personnel is needed, PSEG Nuclear will coordinate the use of alternate media briefing locations with State and County officials.

The communications equipment is described in Section 7 and summarized in Table 7-1. For media use, commercial telephone lines have been assigned from a physically distant exchange, which would reduce the load on local telephone services during an emergency.

Under appropriate circumstances, space for a limited number of press representatives may be made available at the EOF.

6.0 Additional Offsite Capabilities 6.1 Offsite Environmental Radiological Monitoring Section 10, Accident Assessment presents a discussion of other assessment capabilities and instrumentation. The Stations are located on a man-made island, which, within four miles, is surrounded by tidal marshlands or river. The thermo luminescent dosimeter (TLD) points of the routine offsite environmental radiological monitoring program include TLDs in neighboring towns and cities and at schools and public assembly points, and at distances sufficiently close to the station to provide meaningful data in the event of an accident. No TLDs were deployed on marshlands where no serviceable roads existed. The Operational Radiological Monitoring program for the Station conforms to the NRC Radiological Assessment Branch Technical Position as described in Section 10 of the Emergency Plan.

6.2 Meteorological Monitoring A meteorological program in accordance with the recommendation of NRC Regulatory Guide 1.23 "Onsite Meteorological Program" and Section 2.3.3 of NUREG 75/087 (Rev. 3) has been established. Monitoring and assessment capabilities are discussed in Section 10.

The dose calculation methodology of Section 10 of the Emergency Plan, concerning the transport and diffusion of gaseous effluents, is consistent with the characteristics of the Class A model outlines in NUREG-0654 (November 1980).

PSEG NUCLEAR LLC - EP 9.12 Rev. 21 7.0 Field Assessment and Monitoring The EOF, once activated, is the location for collection and assessment of all offsite radiological monitoring information from the survey teams. Periodically the information on doses calculated in accordance with Section 10 of the Plan is multiplied by the projected sector population data from Emergency Plan Attachment 6 to provide an estimated integrated dose to the affected population.

8.0 Administration and Maintenance of Emergency Facilities and Equipment The emergency equipment listed in Table 9-1 is inventoried and operationally checked quarterly, and after each use to allow for replacement in the event of normal servicing and calibration. The instrument calibration frequency has been established in accordance with the appropriate technical guidance.

Table 9-1 is a generic listing of typical equipment maintained both on and offsite.

Detailed listings are part of emergency preparedness inventory procedures.

TABLE 9-1 EMERGENCY EQUIPMENT

SUMMARY

(TYPICAL)

Page 1 of 2 EQUIPMENT CR/OSC CP/Salem Field Team Kit TSC/Hope Creek Field Team Kit EOF/Field Team Kit RO2A Survey Instrument

  • L L

L E

RM14/EL14ON

  • L L

L E

Teletector

  • L L

L E

E520 Survey Instrument

  • L L

L E

RO2 Survey Instrument

  • L L

L E

High Range Dosimeters or Electronic Dosimeters

  • L L

L E

Low Range Dosimeters or Electronic Dosimeters

  • L L

L E

Dosimeter Charger (not needed for Electronic Dosimeters)

A L

L N/A Air Sampler (A/S)

L L

L E

DC Powered A/S A

A A

N/A Marinelli Beaker with A/S Head A

L N/A N/A Charcoal Cartridges for A/S L

L L

E Silver Zeolite Cartridges for A/S (Sealed)

L L

L E

Particulate Filter Papers for A/S L

L L

E Envelops for Particulate A/S L

L L

E Flashlights with Batteries L

L A

E Spare Batteries (replacement set for each instrument)

L L

L E

Sample Containers or Small Bags L

L L

E Smears L

L L

E Rad Info Signs L

A L

A Barricade Rope or Ribbon and Stanchions L

A L

N/A Tape L

L L

E NOTES/LOCATION DESCRIPTIONS A = Accessible in general area of the Emergency Response Facility L = Located at Salem and Hope Creek Emergency Response Facilities E = Located in the EOF or EOF Field Team Kits N/A = Not applicable in that specific Emergency Response Facility

  • = or equivalent PSEG NUCLEAR LLC - EP 9.13 Rev. 21

PSEG NUCLEAR LLC - EP 9.14 Rev. 21 TABLE 9-1 EMERGENCY EQUIPMENT

SUMMARY

(TYPICAL)

Page 2 of 2 EQUIPMENT CR/OSC CP/Salem Field Team Kit TSC/Hope Creek Field Team Kit EOF/Field Team Kit Large Plastic Bags L

L L

E Step-off Pads SOP)

L A

L A

Paper or Cloth Coveralls L

L L

E Shoe Covers A

L L

E Rubber Gloves A

L L

E Hoods and Caps A

L L

E Respirators and Charcoal/Participate Cartridges A

A A

A Emergency Plan Procedures (as applicable)

L L

L E

SCBAs L

A N/A N/A Check Sources (button)

  • L L

L E

KI Tablets L

L L

E Absorbent Material N/A L

L E

Calculator/Computer N/A L

L E

Dosimeters of Legal Record L

A L

E Logs, Paper Supplies, Pens, Clip Boards, etc.

L L

L E

Plastic Sheeting N/A A

A A

First Aid Kit L

L L

E NOTES/LOCATION DESCRIPTIONS A = Accessible in general area of the Emergency Response Facility L = Located at Salem and Hope Creek Emergency Response Facilities E = Located in the EOF or EOF Field Team Kits N/A = Not applicable in that specific Emergency Response Facility

  • = or equivalent
1.

The Control Room/Operations Support Center (CR/OSC) area comprises adjacent hallways, lockers, and storage areas.

2.

Control Point (CP) comprises adjacent and accessible area including lockers, equipment issue areas, and dress out areas.

3.

Technical Support Centers (TSC) are dedicated facilities.

4.

Emergency Operations Facility (EOF) includes the adjacent meeting rooms and Room 50.

5.

The EOF Field Team Kits describes materials reserved for Field Monitoring.