ML110060815

From kanterella
Jump to navigation Jump to search
Salem/Operations, S2.OP-AR.ZZ-0003(Q), Rev. 17, Overhead Annunciators Window C
ML110060815
Person / Time
Site: Salem  
Issue date: 01/21/2010
From:
Public Service Enterprise Group
To:
Office of Nuclear Reactor Regulation
References
LR-N10-0355 S2.OP-AR.ZZ-0003(Q), Rev 17
Download: ML110060815 (58)


Text

PSEG Internal Use Only Page 1 of 1 PSEG NUCLEAR L.L.C.

SALEM/OPERATIONS S2.OP-AR.ZZ-0003(Q) - REV. 17 OVERHEAD ANNUNCIATORS WINDOW C Biennial Review Performed: Yes ____ No T DCP Packages and Affected Document Numbers incorporated into this revision: None OTSC(s) were incorporated into this revision: None OPEX(s) were incorporated into this revision: None REVISION

SUMMARY

Pg. 45, OHA C-38, CFCU Leak Detection High, Step 3.5.D - Added step INITIATE SC.OP-DG.SW-0005, Service Water Spill Response in Containment.

(70103767)

IMPLEMENTATION REQUIREMENTS Effective Date:

01/21/10 None

S2.OP-AR.ZZ-0003(Q)

Salem 2 Page 1 of 57 Rev. 17 OVERHEAD ANNUNCIATORS WINDOW C TABLE OF CONTENTS SECTION PAGE Table of Contents..................................................................... 1 Window C Overview.................................................................. 3 Text............................................................................... 4 WINDOW SECTION C-1 GAS ANLY TRBL.................................................. 4 C-2 CNTMT SUMP PMP START.......................................... 5 C-3 21 CC HX IN TEMP HI.............................................. 6 C-4 21 CFCU AIRFLO TRBL............................................. 7 C-5 21 CFCU WTRFLO TRBL............................................ 8 C-6 CNTMT PRESS HI-HI............................................... 9 C-7 21 H2 RECOMB TRBL.............................................. 10 C-8 N A CNTMT ISOL ACT............................................ 11 C-9 104 PNL TRBL.................................................... 12 C-10 CNTMT SUMP OVRFLO........................................... 13 C-11 22 CC HX IN TEMP HI............................................. 14 C-12 22 CFCU AIRFLO TRBL............................................ 15 C-13 22 CFCU WTRFLO TRBL........................................... 16 C-14 CNTMT PRESS HI................................................. 17 C-15 22 H2 RECOMB TRBL.............................................. 18 C-16 N B CNTMT ISOL ACT............................................. 19 C-17 21-23 CVCS HUT LVL HI........................................... 20 C-18 RX SUMP OVRFLO................................................ 21 C-19 SFP TEMP HI..................................................... 23 C-20 23 CFCU AIRFLO TRBL............................................ 25 C-21 23 CFCU WTRFLO TRBL........................................... 26 C-22 CNTMT SPRY ACT................................................ 27

S2.OP-AR.ZZ-0003(Q)

Salem 2 Page 2 of 57 Rev. 17 TABLE OF CONTENTS (Continued)

WINDOW SECTION PAGE C-23 CNTMT H2 LVL HI................................................ 28 C-24 SPARE........................................................... 29 C-25 BA EVAP TRBL................................................... 30 C-26 21 RHR SUMP OVRFLO............................................ 31 C-27 SFP LVL HI....................................................... 32 C-28 24 CFCU AIRFLO TRBL............................................ 33 C-29 24 CFCU WTRFLO TRBL........................................... 34 C-30 CFCU LK DET HI-HI............................................... 35 C-31 SPARE........................................................... 37 C-32 SPARE........................................................... 38 C-33 RWST/PWST OVRFLO............................................. 39 C-34 22 RHR SUMP OVRFLO............................................ 40 C-35 SFP LVL LO...................................................... 41 C-36 25 CFCU AIRFLO TRBL............................................ 42 C-37 25 CFCU WTRFLO TRBL........................................... 43 C-38 CFCU LK DET HI................................................. 44 C-39 SPARE........................................................... 46 C-40 SPARE........................................................... 47 C-41 SPARE........................................................... 48 C-42 SPARE........................................................... 49 C-43 SPARE........................................................... 50 C-44 SPARE........................................................... 51 C-45 SPARE........................................................... 52 C-46 PERSONNEL ACCESS DOOR OPEN................................. 53 C-47 SPARE........................................................... 54 C-48 SPARE........................................................... 55 References......................................................................... 56

S2.OP-AR.ZZ-0003(Q)

Salem 2 Page 3 of 57 Rev. 17 C

WASTE DISPOSAL LEAK DETECT AUX COOLING CONTAINMENT 1

1 GAS ANLY TRBL M

2 CNTMT SUMP PMP START 3

21 CC HX IN TEMP HI 4

21 CFCU AIRFLO TRBL 5

21 CFCU WTRFLO TRBL 6

CNTMT PRESS HI - HI 7

21 H2 RECOMB TRBL 8

N A CNTMT ISOL ACT 8

9 9

104 PNL TRBL 10 CNTMT SUMP OVRFLO 11 22 CC HX IN TEMP HI 12 22 CFCU AIRFLO TRBL 13 22 CFCU WTRFLO TRBL 14 CNTMT PRESS HI 15 22 H2 RECOMB TRBL 16 N B CNTMT ISOL ACT 16 17 17 21 - 23 CVCS HUT LVL HI M

18 RX SUMP OVRFLO 19 SFP TEMP HI 20 23 CFCU AIRFLO TRBL 21 23 CFCU WTRFLO TRBL 22 CNTMT SPRY ACT 23 CNTMT H2 LVL HI 24 24 25 25 BA EVAP TRBL 26 21 RHR SUMP OVRFLO 27 SFP LVL HI 28 24 CFCU AIRFLO TRBL 29 24 CFCU WTRFLO TRBL 30 CFCU LK DET HI - HI M

31 32 32 33 33 RWST / PWST OVRFLO 34 22 RHR SUMP OVRFLO 35 SFP LVL LO 36 25 CFCU AIRFLO TRBL 37 25 CFCU WTRFLO TRBL 38 CFCU LK DET HI M

39 40 40 41 41 42 43 44 45 46 PERSONNEL ACCESS DOOR OPEN 47 48 48

S2.OP-AR.ZZ-0003(Q)

Salem 2 Page 4 of 57 Rev. 17 ALARM C-1 1

GAS ANLY TRBL M

DEVICES:

N/A SETPOINT:

N/A

1.0 CAUSE(S)

1.1 Cover Gas Low Flow 1.2 AC Power failure 1.3 Hydrogen Low 1.4 DC Power Failure 1.5 WGDT Low Flow 1.6 Recorder Trouble 1.7 Oxygen High/Low 2.0 AUTOMATIC ACTION:

None 3.0 OPERATOR ACTIONS:

3.1 SEND Operator to Waste Disposal Gas Analyzer PNL 110 to determine cause of alarm.

3.2 GO TO S2.OP-AR.WG-0001(Q), Waste Disposal Gas Analyzer PNL 110.

Page 1 of 1 C-1

References:

S2.OP-AR.ZZ-0003(Q)

Salem 2 Page 5 of 57 Rev. 17 ALARM C-2 2

CNTMT SUMP PMP START DEVICES:

N/A SETPOINT:

N/A

1.0 CAUSE(S)

21 or 22 Containment Sump Pumps started 2.0 AUTOMATIC ACTION:

None 3.0 OPERATOR ACTIONS:

3.1 IF any indication of an RCS leak or an interconnecting ECCS leak affecting RCS inventory, THEN GO TO S2.OP-AB.RC-0001(Q), Reactor Coolant System Leak.

3.2 DETERMINE a leakrate IAW S2.OP-SO.RC-0004(Q),

Identifying and Measuring Leakage.

A.

IF leakrate is $ 1 gpm, THEN REFER to Technical Specifications.

B.

IF leakrate is trending up, THEN:

1.

SEND an Operator into Containment to determine source of leak.

2.

INITIATE a NOTF IAW LS-AA-120, Issue Identification and Screening Process 3.3 MONITOR the WHUT levels.

Page 1 of 1 C-2

References:

Dwg. 220972

S2.OP-AR.ZZ-0003(Q)

Salem 2 Page 6 of 57 Rev. 17 ALARM C-3 3

21 CC HX IN TEMP HI DEVICES:

2TIC627A SETPOINT:

$ 170°F

1.0 CAUSE(S)

Inlet temperature is $ 170°F 2.0 AUTOMATIC ACTION:

None 3.0 OPERATOR ACTIONS:

3.1 IF alarm is due to loss of Service Water pressure, THEN GO TO S2.OP-AB.SW-0001(Q), Loss of Service Water Header Pressure.

3.2 IF alarm is due to loss of Component Cooling Water, THEN GO TO S2.OP-AB.CC-0001(Q), Component Cooling Abnormality.

3.3 SEND an operator to perform the following:

INVESTIGATE the cause of the alarm.

ALIGN CCHXs as directed IAW S2.OP-SO.CC-0002(Q),

21 & 22 Component Cooling Heat Exchanger Operation.

3.5 REFER to Technical Specifications 3.7.3 and 3.7.4.

Page 1 of 1 C-3

References:

Dwg. 205331, 211522

S2.OP-AR.ZZ-0003(Q)

Salem 2 Page 7 of 57 Rev. 17 ALARM C-4 4

21 CFCU AIRFLO TRBL DEVICES:

N/A SETPOINT:

N/A

1.0 CAUSE(S)

1.1 Roughing Filter Dampers not fully OPEN 1.2 HEPA Filter Inlet Damper not fully CLOSED 1.3 HEPA Filter Outlet Damper not fully CLOSED 2.0 AUTOMATIC ACTION:

None 3.0 OPERATOR ACTIONS:

3.1 IF 21 Containment Fan Coil Unit is operating in low speed, THEN no further Operator action is required.

3.2 VERIFY positions of 21 Containment Fan Coil Filter Dampers on Control Console bezels.

3.3 IF damper malfunction is indicated, THEN:

A.

STOP 21 Containment Fan Coil Unit.

B.

INITIATE a NOTF IAW LS-AA-120, Issue Identification and Screening Process.

3.4 REFER to Technical Specification 3.6.2.3.

Page 1 of 1 C-4

References:

Dwg. 205338, 203568

S2.OP-AR.ZZ-0003(Q)

Salem 2 Page 8 of 57 Rev. 17 ALARM C-5 5

21 CFCU WTRFLO TRBL DEVICES:

N/A SETPOINT:

N/A

1.0 CAUSE(S)

Any SW Valve misaligned with the CFCU running:

21SW58, 21 FAN COIL UNIT INLET WATER VALVE not fully OPEN 21SW72, 21 FAN COIL UNIT OUTLET WATER VALVE not fully OPEN 21SW223, 21 FAN COIL UNIT OUTLET WATER FLOW CONTROL VALVE is CLOSED 2.0 AUTOMATIC ACTION:

None 3.0 OPERATOR ACTIONS:

3.1 CONFIRM alarm by observing flow indication on 21 CFCU bezel.

3.2 OPEN the following valves:

A.

21SW58, 21 FAN COIL UNIT INLET WATER VALVE B.

21SW72, 21 FAN COIL UNIT OUTLET WATER VALVE 3.3 IF a valve malfunction is suspected, THEN:

A.

STOP 21 Containment Fan Coil Unit.

B.

INITIATE a NOTF IAW LS-AA-120, Issue Identification and Screening Process C.

REFER to Technical Specification 3.6.2.3 Page 1 of 1 C-5

References:

Dwg. 205342, 203570

S2.OP-AR.ZZ-0003(Q)

Salem 2 Page 9 of 57 Rev. 17 ALARM C-6 6

CNTMT PRESS HI-HI DEVICES:

2PC948A, 2PC948B, 2PC948C, 2PC948G SETPOINT:

$ 15 psig

1.0 CAUSE(S)

Containment pressure channel $ 15 psig.

2.0 AUTOMATIC ACTION:

None 3.0 OPERATOR ACTIONS:

3.1 CONFIRM alarm by verifying indication.

3.2 IF alarm is due to testing, THEN no further action is required.

3.3 IF instrument failure is suspected, THEN:

A.

REMOVE affected channel from service IAW S2.OP-SO.RPS-0005(Q),

Placing Containment Pressure Channel In Tripped Condition.

B.

INITIATE a NOTF IAW LS-AA-120, Issue Identification and Screening Process 3.4 REFER to Technical Specification 3.3.2.1.

Page 1 of 1 C-6

References:

Dwg. 221057

S2.OP-AR.ZZ-0003(Q)

Salem 2 Page 10 of 57 Rev. 17 ALARM C-7 7

21 H2 RECOMB TRBL DEVICES:

N/A SETPOINT:

  1. 350V input voltage

1.0 CAUSE(S)

Input voltage is # 350V 2.0 AUTOMATIC ACTION:

None 3.0 OPERATOR ACTIONS:

3.1 IF alarm is due to testing, THEN no further Operator action is required.

3.2 ENSURE CLOSED breaker 2AX1AX15X at 2A 460V Vital Bus.

3.3 REFER to Technical Specification 3.6.4.2.

3.4 INITIATE a NOTF IAW LS-AA-120, Issue Identification and Screening Process Page 1 of 1 C-7

References:

Dwg. 203653

S2.OP-AR.ZZ-0003(Q)

Salem 2 Page 11 of 57 Rev. 17 ALARM C-8 8

N A CNTMT ISOL ACT DEVICES:

N/A SETPOINT:

N/A

1.0 CAUSE(S)

1.1 Containment Isolation Phase A manual actuation 1.2 Safety Injection signal 2.0 AUTOMATIC ACTION:

Phase A valves displayed on Panel 2RP4 CLOSE.

3.0 OPERATOR ACTIONS:

3.1 IF alarm is due to an SI, THEN GO TO 2-EOP-TRIP-1, Reactor Trip or Safety Injection.

3.2 CONFIRM alarm by observing Panel 2RP4 or actual valve position indication on Control Room Console.

3.3 IF alarm is due to a failure, THEN:

A.

EVALUATE components affected.

B.

INITIATE a NOTF IAW LS-AA-120, Issue Identification and Screening Process.

C.

When notified of corrective action completion by Maintenance, RESET the alarm.

3.4 REFER to Technical Specification 3.3.2.1.

Page 1 of 1 C-8

References:

Dwg. 221057, 232015

S2.OP-AR.ZZ-0003(Q)

Salem 2 Page 12 of 57 Rev. 17 ALARM C-9 9

104 PNL TRBL DEVICES:

N/A SETPOINT:

N/A

1.0 CAUSE(S)

An alarm on Panel 104, Waste Disposal-Boron Recycle Panel 2.0 AUTOMATIC ACTION:

None 3.0 OPERATOR ACTIONS:

3.1 SEND an Operator to Panel 104, Waste Disposal-Boron Recycle Panel to perform the following:

A.

DETERMINE cause of the alarm.

B.

INITIATE corrective action IAW S2.OP-AR.ZZ-0016(Q), Panel 104 Alarms.

Page 1 of 1 C-9

References:

Dwg. 226513

S2.OP-AR.ZZ-0003(Q)

Salem 2 Page 13 of 57 Rev. 17 ALARM C-10 10 CNTMT SUMP OVRFLO DEVICES:

2LD2067 SETPOINT:

$ 75 feet 1 inch

1.0 CAUSE(S)

Containment Sump level $ 75 feet 1 inch 2.0 AUTOMATIC ACTION:

None 3.0 OPERATOR ACTIONS:

3.1 IF Containment Sump Overflow is due to "N A Isolation" THEN RETURN to procedure in effect.

3.2 ENSURE OPEN the following valves:

A.

2WL16, CONT SUMP DISCH TO WHUT B.

2WL17, CONT SUMP DISCH TO WHUT 3.3 IF Containment Sump Pump(s) failed to start, THEN VERIFY CLOSED:

Breaker 2GY1AX6J, 21 Containment Sump Pump Breaker 2EY3AX6J, 22 Containment Sump Pump 3.4 ENSURE Containment Sump Pumps have started.

3.5 IF any indication of an RCS leak or an interconnecting ECCS leak affecting RCS inventory, THEN GO TO S2.OP-AB.RC-0001(Q), Reactor Coolant System Leak.

3.6 DETERMINE a leakrate IAW S2.OP-ST.RC-0008(Q), RCS Water Inventory Balance.

A.

IF leakrate is trending up, THEN SEND an Operator into Containment to determine source of leak.

B.

IF leakrate is $ 1 gpm, THEN REFER to Technical Specifications.

Page 1 of 1 C-10

References:

Dwg. 205326, 220972, 211514

S2.OP-AR.ZZ-0003(Q)

Salem 2 Page 14 of 57 Rev. 17 ALARM C-11 11 22 CC HX IN TEMP HI DEVICES:

2TIC627B SETPOINT:

$ 170°F

1.0 CAUSE(S)

Inlet temperature is $ 170°F 2.0 AUTOMATIC ACTION:

None 3.0 OPERATOR ACTIONS:

3.1 IF alarm is due to loss of Service Water pressure, THEN GO TO S2.OP-AB.SW-0001(Q), Loss of Service Water Header Pressure.

3.2 IF alarm is due to loss of Component Cooling Water, THEN GO TO S2.OP-AB.CC-0001(Q), Component Cooling Abnormality.

3.3 SEND an operator to perform the following:

INVESTIGATE the cause of the alarm.

ALIGN CCHXs as directed IAW S2.OP-SO.CC-0002(Q),

21 & 22 Component Cooling Heat Exchanger Operation.

3.5 REFER to Technical Specifications 3.7.3 and 3.7.4.

Page 1 of 1 C-11

References:

Dwg. 205331, 211523

S2.OP-AR.ZZ-0003(Q)

Salem 2 Page 15 of 57 Rev. 17 ALARM C-12 12 22 CFCU AIRFLO TRBL DEVICES:

N/A SETPOINT:

N/A

1.0 CAUSE(S)

1.1 Roughing Filter Dampers not fully OPEN 1.2 HEPA Filter Inlet Damper not fully CLOSED 1.3 HEPA Filter Outlet Damper not fully CLOSED 2.0 AUTOMATIC ACTION:

None 3.0 OPERATOR ACTIONS:

3.1 IF 22 Containment Fan Coil Unit is operating in low speed, THEN no further Operator action is required.

3.2 ENSURE the positions of 22 Containment Fan Coil Filter Dampers on the Control Console bezels.

3.3 IF damper malfunction is indicated, THEN:

A.

STOP 22 Containment Fan Coil Unit.

B.

INITIATE a NOTF IAW LS-AA-120, Issue Identification and Screening Process 3.4 REFER to Technical Specification 3.6.2.3.

Page 1 of 1 C-12

References:

Dwg. 205338, 203572

S2.OP-AR.ZZ-0003(Q)

Salem 2 Page 16 of 57 Rev. 17 ALARM C-13 13 22 CFCU WTRFLO TRBL DEVICES:

N/A SETPOINT:

N/A

1.0 CAUSE(S)

Any SW Valve misaligned with the CFCU running:

22SW58, 22 FAN COIL UNIT INLET WATER VALVE not fully OPEN 22SW72, 22 FAN COIL UNIT OUTLET WATER VALVE not fully OPEN 22SW223, 22 FAN COIL UNIT OUTLET WATER FLOW CONTROL VALVE, is CLOSED 2.0 AUTOMATIC ACTION:

None 3.0 OPERATOR ACTIONS:

3.1 CONFIRM alarm by observing flow indication on 22 CFCU bezel.

3.2 ENSURE OPEN the following valves:

A.

22SW58, 22 FAN COIL UNIT INLET WATER VALVE B.

22SW72, 22 FAN COIL UNIT OUTLET WATER VALVE 3.3 IF a valve malfunction is suspected, THEN:

A.

STOP 22 Containment Fan Coil Unit.

B.

INITIATE a NOTF IAW LS-AA-120, Issue Identification and Screening Process 3.4 REFER to Technical Specification 3.6.2.3.

Page 1 of 1 C-13

References:

Dwg. 205342, 203574

S2.OP-AR.ZZ-0003(Q)

Salem 2 Page 17 of 57 Rev. 17 ALARM C-14 14 CNTMT PRESS HI DEVICES:

2PC948D, 2PC948E, 2PC948F SETPOINT:

$ 4 psig

1.0 CAUSE(S)

Containment pressure channel $ 4 psig 2.0 AUTOMATIC ACTION:

None 3.0 OPERATOR ACTIONS:

3.1 CONFIRM alarm by verifying indication.

3.2 IF alarm is due to testing, THEN no further action is required.

3.3 IF instrument failure is suspected, THEN:

A.

REMOVE affected channel from service IAW S2.OP-SO.RPS-0005(Q),

Placing Containment Pressure Channel In Tripped Condition.

B.

INITIATE a NOTF IAW LS-AA-120, Issue Identification and Screening Process 3.4 REFER to Technical Specification 3.3.2.1.

Page 1 of 1 C-14

References:

Dwg. 221057

S2.OP-AR.ZZ-0003(Q)

Salem 2 Page 18 of 57 Rev. 17 ALARM C-15 15 22 H2 RECOMB TRBL DEVICES:

N/A SETPOINT:

  1. 350V input voltage

1.0 CAUSE(S)

Input voltage is # 350V 2.0 AUTOMATIC ACTION:

None 3.0 OPERATOR ACTIONS:

3.1 IF alarm is due to testing, THEN no further action is required.

3.2 ENSURE CLOSED breaker 2BX1AX15X on 2B 460V Vital Bus for No. 22 Hydrogen Recombiner 3.3 REFER to Technical Specification 3.6.4.2.

3.4 INITIATE a NOTF IAW LS-AA-120, Issue Identification and Screening Process.

Page 1 of 1 C-15

References:

Dwg. 203654

S2.OP-AR.ZZ-0003(Q)

Salem 2 Page 19 of 57 Rev. 17 ALARM C-16 16 N B CNTMT ISOL ACT DEVICES:

2PC948A, 2PC948B, 2PC948C, 2PC948G SETPOINT:

$ 15 psig

1.0 CAUSE(S)

1.1 Two out of four Containment pressure channels are $ 15 psig 1.2 Manual Actuation 2.0 AUTOMATIC ACTION:

2.1 N B valves on Panel 2RP4 CLOSE.

2.2 Containment Spray Valves on Panel 2RP4 OPEN 2.3 Containment Spray Pumps START (if SEC permissive exists) 3.0 OPERATOR ACTIONS:

3.1 CONFIRM alarm by verifying coincidence on Panel 2RP4 OR valve indications on Control Console.

3.2 IF Containment pressure is $ 15 psig, THEN:

A.

TRIP the Reactor.

B.

GO TO 2-EOP-TRIP-1, Reactor Trip or Safety Injection.

3.3 IF Containment pressure is # 15 psig, THEN:

A.

Attempt to RESET AND OPEN the Phase B Containment Isolation Valves.

B.

IF unable to reset Phase B Containment Isolation, THEN GO TO S2.OP-AB.RCP-0001(Q), RCP Abnormality, for loss of CCW flow to all RCP Motors.

Page 1 of 1 C-16

References:

Dwg. 221057, 232016

S2.OP-AR.ZZ-0003(Q)

Salem 2 Page 20 of 57 Rev. 17 ALARM C-17 17 21-23 CVCS HUT LVL HI M

DEVICES:

2LT167, 2LT168, 2LT170 SETPOINT:

$ 90%

1.0 CAUSE(S)

Any CVCS HUT level $ 90%

2.0 AUTOMATIC ACTION:

None 3.0 OPERATOR ACTIONS:

3.1 DETERMINE which CVCS HUT is causing the alarm from the Annunciator CRT:

CRT Point Description 173 21 CVCS HOLDUP TANK LEVEL HIGH 180 22 CVCS HOLDUP TANK LEVEL HIGH 188 23 CVCS HOLDUP TANK LEVEL HIGH 3.2 SEND an operator to PLACE an unaffected tank in service IAW S2.OP-SO.CVC-0004(Q), CVCS Holdup Tank System Operations.

Page 1 of 1 C-17

References:

Dwg. 205329

S2.OP-AR.ZZ-0003(Q)

Salem 2 Page 21 of 57 Rev. 17 ALARM C-18 18 RX SUMP OVRFLO DEVICES:

2LD7752 SETPOINT:

$ 54 feet

1.0 CAUSE(S)

Reactor Sump level $ 54 feet 2.0 AUTOMATIC ACTION:

None 3.0 OPERATOR ACTIONS:

3.1 IF in Modes 1-5, THEN:

A.

IF Reactor Sump Pump has not started, THEN VERIFY CLOSED breaker 2EY3AX6G for 2 Reactor Sump Pump B.

ENSURE Reactor Sump Pump has started.

C.

IF any indication of an RCS leak or an interconnecting ECCS leak affecting RCS inventory, THEN GO TO S2.OP-AB.RC-0001(Q), Reactor Coolant System Leak.

D.

DETERMINE a leakrate IAW S2.OP-ST.RC-0008(Q),

RCS Water Inventory Balance.

E.

INITIATE a NOTF IAW LS-AA-120, Issue Identification and Screening Process, as required.

(Continued)

Page 1 of 2 C-18

S2.OP-AR.ZZ-0003(Q)

Salem 2 Page 22 of 57 Rev. 17 3.2 IF in Mode 6, THEN:

A.

IF Reactor Cavity level is decreasing, THEN GO TO S2.OP-AB.FUEL-0002(Q),

Loss of Refueling Cavity or Spent Fuel Pool Level.

B.

IF Reactor Cavity level is stable, THEN:

1.

VERIFY CLOSED breaker 2EY3AX6G for 2 Reactor Sump Pump.

2.

SEND an operator to determine the source of the leakage.

3.

INITIATE a NOTF IAW LS-AA-120, Issue Identification and Screening Process, as required.

Page 2 of 2 C-18

References:

Dwg. 205326, 220972, 240698

S2.OP-AR.ZZ-0003(Q)

Salem 2 Page 23 of 57 Rev. 17 ALARM C-19 19 SFP TEMP HI DEVICES:

2TIC651 SETPOINT:

125°F OR a temporary alarm setpoint may be in effect to support refueling outages (specifically reactor core off-loads).

NOTE This alarm is expected during refueling outages during core off-load. The alarm setpoint may have to be raised to meet the commitment to maintain a loss of SFP cooling alarm.

1.0 CAUSE(S)

1.1 Spent Fuel Pit temperature $125°F.

1.2 Spent Fuel Pit temperature is greater than the temporary alarm setpoint during refueling.

2.0 AUTOMATIC ACTION:

None 3.0 OPERATOR ACTIONS:

3.1 SEND operator to validate cause of alarm.

3.2 REMOVE the Spent Fuel Demineralizer from service IAW S2.OP-SO.SF-0002(Q),

Spent Fuel Cooling System Operation prior to reaching a Spent Fuel Pit temperature (TIC651) of 130°F.

(continued on next page)

Page 1 of 2 C-19

S2.OP-AR.ZZ-0003(Q)

Salem 2 Page 24 of 57 Rev. 17 3.0 OPERATOR ACTIONS (continued) 3.3 IF the Spent Fuel Pit temperature is >125°F AND reactor core off-load is either in progress or completely off-loaded, THEN:

A.

INITIATE a continuous watch to monitor SFP temperature until the alarm setpoint is adjusted, as applicable, and the alarm is clear.

1.

INITIATE Temporary readings IAW SH.OP-DL.ZZ-0027 AND RECORD Spent Fuel Pit temperature (TIC651) every half hour until alarm setpoint has been changed, AND the Spent Fuel Demineralizer has been removed from service.

2.

IF the Alarm is adjusted, AND the Spent Fuel Demineralizer is out of service, THEN RECORD the Spent Fuel Pit temperature (TIC651) every four hours until the alarm setpoint has been returned to normal (125°F).

B.

INITIATE a NOTF to Maintenance to adjust the alarm setpoint as provided by Outage Engineering (Refer to S-C-SF-MDC-1800).

3.4 IF SFP cooling cannot be maintained below the alarm setpoint

(<125°F or < the temporary alarm setpoint in effect during Refueling Outages),

OR any unexpected loss of SFP cooling, THEN GO TO S2.OP-AB.SF-0001(Q), Loss of Spent Fuel Pool Cooling.

Page 2 of 2 C-19

References:

Dwg. 205333, 231100. S-C-SF-MDC-1800

S2.OP-AR.ZZ-0003(Q)

Salem 2 Page 25 of 57 Rev. 17 ALARM C-20 20 23 CFCU AIRFLO TRBL DEVICES:

N/A SETPOINT:

N/A

1.0 CAUSE(S)

1.1 Roughing Filter Dampers not fully open 1.2 HEPA Filter Inlet Damper not fully closed 1.3 HEPA Filter Outlet Damper not fully closed 2.0 AUTOMATIC ACTION:

None 3.0 OPERATOR ACTIONS:

3.1 IF 23 Containment Fan Coil Unit is operating in low speed, THEN no further action is required.

3.2 VERIFY positions of 23 Containment Fan Coil Filter Dampers on Control Console bezels.

3.3 IF damper malfunction is indicated, THEN:

A.

STOP 23 Containment Fan Coil Unit.

B.

INITIATE a NOTF IAW LS-AA-120, Issue Identification and Screening Process 3.4 REFER to Technical Specification 3.6.2.3.

Page 1 of 1 C-20

References:

Dwg. 205338, 203576

S2.OP-AR.ZZ-0003(Q)

Salem 2 Page 26 of 57 Rev. 17 ALARM C-21 21 23 CFCU WTRFLO TRBL DEVICES:

N/A SETPOINT:

N/A

1.0 CAUSE(S)

Any SW Valve misalignment with the CFCU running:

23SW58, 23 FAN COIL UNIT INLET WATER VALVE not fully OPEN 23SW72, 23 FAN COIL UNIT OUTLET WATER VALVE not fully OPEN 23SW223, 23 FAN COIL UNIT OUTLET WATER FLOW CONTROL VALVE, is CLOSED 2.0 AUTOMATIC ACTION:

None 3.0 OPERATOR ACTIONS:

3.1 CONFIRM alarm by observing flow indication on 23 CFCU bezel.

3.2 ENSURE OPEN the following valves:

A.

23SW58, 23 FAN COIL UNIT INLET WATER VALVE B.

23SW72, 23 FAN COIL UNIT OUTLET WATER VALVE 3.3 IF a valve malfunction is suspected, THEN:

A.

STOP 23 Containment Fan Coil Unit.

B.

INITIATE a NOTF IAW LS-AA-120, Issue Identification and Screening Process 3.4 REFER to Technical Specification 3.6.2.3.

Page 1 of 1 C-21

References:

Dwg. 205342, 203578

S2.OP-AR.ZZ-0003(Q)

Salem 2 Page 27 of 57 Rev. 17 ALARM C-22 22 CNTMT SPRY ACT DEVICES:

2PC948A, 2PC948B, 2PC948C, 2PC948G SETPOINT:

$ 15 psig

1.0 CAUSE(S)

1.1 Two out of four Containment pressure channels are $ 15 psig 1.2 Manual actuation 2.0 AUTOMATIC ACTION:

2.1 Containment Spray Valves OPEN 2.2 Containment Spray Pumps START (if SEC permissives exists) 2.3 Containment Isolation Phase B 2.4 Containment Ventilation Isolation (manual signal only) 2.5 Main Steamline Isolation (automatic signal only) 3.0 OPERATOR ACTIONS:

3.1 IF alarm due to testing, THEN no further Operator action required.

3.2 CONFIRM alarm by verifying coincidence on Panel 2RP4 AND Main Control Console indications.

3.3 GO TO 2-EOP-TRIP-1, Reactor Trip or Safety Injection.

Page 1 of 1 C-22

References:

Dwg. 221057

S2.OP-AR.ZZ-0003(Q)

Salem 2 Page 28 of 57 Rev. 17 ALARM C-23 23 CNTMT H2 LVL HI DEVICES:

SETPOINT:

$ 2% hydrogen

1.0 CAUSE(S)

Hydrogen concentration in Containment atmosphere is $ 2%

2.0 AUTOMATIC ACTION:

None 3.0 OPERATOR ACTIONS:

3.1 IF alarm is due to testing, THEN no further Operator action is required.

3.2 CONFIRM alarm by observing Control Room charts and H2 monitors (2RP5).

3.3 IF alarm is valid, THEN:

A.

NOTIFY Chemistry for a confirming sample.

B.

PLACE Recombiner in service IAW S2.OP-SO.CAN-0001(Q),

Hydrogen Recombiner Operation.

C.

REFER to Event Classification Guide.

3.4 REFER to Technical Specifications 3.6.4.1.

Page 1 of 1 C-23

References:

Dwg. 252310

S2.OP-AR.ZZ-0003(Q)

Salem 2 Page 29 of 57 Rev. 17 ALARM C-24 24 SPARE DEVICES:

SETPOINT:

Page 1 of 1 C-24

References:

Dwg.

S2.OP-AR.ZZ-0003(Q)

Salem 2 Page 30 of 57 Rev. 17 ALARM C-25 25 BA EVAP TRBL DEVICES:

N/A SETPOINT:

N/A

1.0 CAUSE(S)

An alarm at Panel 301, Gas Stripper & Boron Concentrate Panel 2.0 AUTOMATIC ACTION:

None 3.0 OPERATOR ACTIONS:

3.1 SEND an Operator to Panel 301-2, Gas Stripper & Boron Concentrate Panel, to perform the following:

A.

DETERMINE cause of the alarm.

B.

INITIATE corrective action.

Page 1 of 1 C-25

References:

Dwg. 222875

S2.OP-AR.ZZ-0003(Q)

Salem 2 Page 31 of 57 Rev. 17 ALARM C-26 26 21 RHR SUMP OVRFLO DEVICES:

2LD7753, 2LD7754 SETPOINT:

$ 42 feet

1.0 CAUSE(S)

21 RHR Sump level $ 42 feet 2.0 AUTOMATIC ACTION:

None 3.0 OPERATOR ACTIONS:

3.1 IF RHR Sump Pumps have not started, THEN VERIFY CLOSED breakers:

2CY2AX5A, #21 RHR Sump Pump 2BY2AX5A, #22 RHR Sump Pump 3.2 SEND an Operator to the RHR Pump room and 84 ft elevation to determine source of leak.

3.3 ESTABLISH conditions required to isolate leak.

3.4 IF RHR System must be isolated, THEN GO TO one of the following procedures, as applicable:

S2.OP-AB.RHR-0001(Q), Loss of RHR S2.OP-AB.RHR-0002(Q), Loss of RHR At Reduced Inventory 3.5 REFER to Technical Specifications 3.4.1.3, 3.4.1.4, 3.5.2, 3.5.3, 3.9.8.1, and 3.9.8.2.

Page 1 of 1 C-26

References:

Dwg. 205326, 231035

S2.OP-AR.ZZ-0003(Q)

Salem 2 Page 32 of 57 Rev. 17 ALARM C-27 27 SFP LVL HI DEVICES:

2LC650 SETPOINT:

$ 129 feet 2 inches

1.0 CAUSE(S)

Pool level $ 129 feet 2 inches 2.0 AUTOMATIC ACTION:

None 3.0 OPERATOR ACTIONS:

3.1 IF alarm due to testing, THEN no further action required.

3.2 SEND Operator to confirm that a high level exists in the Spent Fuel Pool.

3.3 ENSURE CLOSED the following makeup valves:

A.

2SF44, PRIMARY WATER MAKEUP VALVE B.

2SF58, DEMIN WATER MAKEUP C.

2SF71, SPENT FUEL PIT FILL FROM HUT 3.4 IF alarm due to Cross-Connect Operations, THEN MONITOR level closely to prevent overfill of Spent Fuel Pool.

3.5 REDUCE level in Spent Fuel Pool to clear alarm IAW S2.OP-SO.SF-0001(Q),

Fill and Transfer of the Spent Fuel Pool.

3.6 IF a failed instrument is indicated, THEN INITIATE a NOTF IAW LS-AA-120, Issue Identification and Screening Process Page 1 of 1 C-27

References:

Dwg. 205333, 231100

S2.OP-AR.ZZ-0003(Q)

Salem 2 Page 33 of 57 Rev. 17 ALARM C-28 28 24 CFCU AIRFLO TRBL DEVICES:

N/A SETPOINT:

N/A

1.0 CAUSE(S)

1.1 Roughing Filter Dampers not fully OPEN 1.2 HEPA Filter Inlet Damper not fully CLOSED 1.3 HEPA Filter Outlet Damper not fully CLOSED 2.0 AUTOMATIC ACTION:

None 3.0 OPERATOR ACTIONS:

3.1 IF 24 Containment Fan Coil Unit is operating in low speed, THEN no further Operator action is required.

3.2 VERIFY positions of 24 Containment Fan Coil Filter Dampers on Control Console bezels.

3.3 IF damper malfunction is indicated, THEN:

A.

STOP 24 Containment Fan Coil Unit.

B.

INITIATE a NOTF IAW LS-AA-120, Issue Identification and Screening Process 3.4 REFER to Technical Specification 3.6.2.3.

Page 1 of 1 C-28

References:

Dwg. 205338, 203580

S2.OP-AR.ZZ-0003(Q)

Salem 2 Page 34 of 57 Rev. 17 ALARM C-29 29 24 CFCU WTRFLO TRBL DEVICES:

N/A SETPOINT:

N/A

1.0 CAUSE(S)

Any SW Valve misalignment with the CFCU running:

24SW58, 24 FAN COIL UNIT INLET WATER VALVE not fully OPEN 24SW72, 24 FAN COIL UNIT OUTLET WATER VALVE not fully OPEN 24SW223, 24 FAN COIL UNIT OUTLET WATER FLOW CONTROL VALVE, is CLOSED 2.0 AUTOMATIC ACTION:

None 3.0 OPERATOR ACTIONS:

3.1 CONFIRM alarm by observing flow indication on 24 CFCU bezel.

3.2 OPEN the following valves:

A.

24SW58, 24 FAN COIL UNIT INLET WATER VALVE B.

24SW72, 24 FAN COIL UNIT OUTLET WATER VALVE 3.3 IF a valve malfunction is suspected, THEN:

A.

STOP 24 Containment Fan Coil Unit.

B.

INITIATE a NOTF IAW LS-AA-120, Issue Identification and Screening Process 3.4 REFER to Technical Specification 3.6.2.3.

Page 1 of 1 C-29

References:

Dwg. 205342, 203582

S2.OP-AR.ZZ-0003(Q)

Salem 2 Page 35 of 57 Rev. 17 ALARM C-30 30 CFCU LK DET HI-HI M

DEVICES:

2LT730, 2LT731, 2LT732, 2LT733, 2LT734 SETPOINT:

$ 15.2 feet of water

1.0 CAUSE(S)

Leak detector level $ 15.2 feet of water 2.0 AUTOMATIC ACTION:

None 3.0 OPERATOR ACTIONS:

3.1 DETERMINE which CFCU is causing the alarm from the Annunciator CRT:

CRT Point Description 497 CONTAINMENT FAN COIL UNIT 21 LEAK DETECTOR HIGH-HIGH 498 CONTAINMENT FAN COIL UNIT 22 LEAK DETECTOR HIGH-HIGH 499 CONTAINMENT FAN COIL UNIT 23 LEAK DETECTOR HIGH-HIGH 500 CONTAINMENT FAN COIL UNIT 24 LEAK DETECTOR HIGH-HIGH 501 CONTAINMENT FAN COIL UNIT 25 LEAK DETECTOR HIGH-HIGH (Continued)

Page 1 of 2 C-30

S2.OP-AR.ZZ-0003(Q)

Salem 2 Page 36 of 57 Rev. 17 3.2 ENSURE OPEN 21-25WD50, CFCU CONDENSATE SHUTOFF, at 2RP1.

3.3 IF there is indication of leakage other than Service Water, THEN INITIATE a leakrate IAW S2.OP-SO.RC-0004(Q),

Identifying and Measuring Leakage.

3.4 IF there is indication of a Service Water leak, THEN:

A.

STOP the affected CFCU.

CAUTION Isolating a CFCU from the control room with the SW58 and SW72 valves also isolates SW overpressure protection for the CFCU. These valves should only be used when there is a SW leak requiring immediate isolation.

B.

ISOLATE the affected CFCU IAW S2.OP-SO.SW-0005(Q),

Service Water System Operation.

C.

INITIATE a NOTF IAW LS-AA-120, Issue Identification and Screening Process.

3.5 REFER to Technical Specification 3.6.1.1 and 3.6.2.3.

Page 2 of 2 C-30 Reference Dwg. 205327, 220061, 240690

S2.OP-AR.ZZ-0003(Q)

Salem 2 Page 37 of 57 Rev. 17 ALARM C-31 31 DEVICES:

SETPOINT:

SPARE Page 1 of 1 C-31

References:

Dwg.

S2.OP-AR.ZZ-0003(Q)

Salem 2 Page 38 of 57 Rev. 17 ALARM C-32 32 DEVICES:

SETPOINT:

SPARE Page 1 of 1 C-32

References:

Dwg.

S2.OP-AR.ZZ-0003(Q)

Salem 2 Page 39 of 57 Rev. 17 ALARM C-33 33 RWST/PWST OVRFLO DEVICES:

1LD8040 SETPOINT:

N/A

1.0 CAUSE(S)

1.1 Overflow from Unit 1 RWST or PWST 1.2 Overflow from Unit 2 RWST or PWST 2.0 AUTOMATIC ACTIONS:

None 3.0 OPERATOR ACTIONS:

3.1 DETERMINE which tank causing alarm.

A.

STOP MAKEUP to affected tank.

B.

SEND an operator to drain the dike area around 13 CVCS HUT as follows:.

1.

Throttle OPEN 1WD7, 13 CVCS HUT DIKE DRAIN VALVE.

2.

MONITOR Auxiliary Building Sump Tank level.

3.

WHEN draining is completed, THEN CLOSE 1WD7, 13 CVCS HUT DIKE DRAIN VALVE.

3.2 WHEN dike is drained and affected tank level restored, THEN:

A.

ESTABLISH communications with the control room.

B.

Throttle OPEN 1WD54, RWST & PWST TO WHT DRN VALVE, to drain level detector 1LD8040 AND clear alarm.

Page 1 of 1 C-33

References:

Dwg. 205234

S2.OP-AR.ZZ-0003(Q)

Salem 2 Page 40 of 57 Rev. 17 ALARM C-34 34 22 RHR SUMP OVRFLO DEVICES:

2LD7755, 2LD7756 SETPOINT:

$ 42 feet

1.0 CAUSE(S)

22 RHR Sump level $ 42 feet 2.0 AUTOMATIC ACTION:

None 3.0 OPERATOR ACTIONS:

3.1 IF RHR Sump Pumps have not started, THEN VERIFY CLOSED breakers:

2CY2AX6A, #23 RHR Sump Pump 2BY2AX6A, #24 RHR Sump Pump 3.2 SEND Operator to RHR Pump room and 84 ft elevation to determine source of leak.

3.3 ESTABLISH conditions required to isolate leak.

3.4 IF RHR System must be isolated, THEN GO TO one of the following procedures, as applicable:

S2.OP-AB.RHR-0001(Q), Loss of RHR S2.OP-AB.RHR-0002(Q), Loss of RHR At Reduced Inventory 3.5 REFER to Technical Specifications 3.4.1.3, 3.4.1.4, 3.5.2, 3.5.3, 3.9.8.1, and 3.9.8.2.

Page 1 of 1 C-34

References:

Dwg. 205326, 231036

S2.OP-AR.ZZ-0003(Q)

Salem 2 Page 41 of 57 Rev. 17 ALARM C-35 35 SFP LVL LO DEVICES:

2LC650 SETPOINT:

  1. 128 feet 2 inches

1.0 CAUSE(S)

Spent Fuel Pit level is # 128 feet 2 inches 2.0 AUTOMATIC ACTION:

None 3.0 OPERATOR ACTIONS:

3.1 IF alarm is due to testing, THEN no further Operator action is required.

3.2 IF in Modes 1-5, THEN:

A.

CONFIRM the alarm.

B.

DETERMINE source of the leak.

C.

INITIATE makeup to Spent Fuel Pit IAW S2.OP-SO.SF-0001(Q),

Fill and Transfer of the Spent Fuel Pool.

3.3 IF in Mode 6, THEN:

A.

SEND Operator to confirm the alarm.

B.

IF Spent Fuel Pool level is decreasing, THEN GO TO S2.OP-AB.FUEL-0002(Q),

Loss of Refueling Cavity or Spent Fuel Pool Level.

Page 1 of 1 C-35

References:

Dwg. 205333, 231100

S2.OP-AR.ZZ-0003(Q)

Salem 2 Page 42 of 57 Rev. 17 ALARM C-36 36 25 CFCU AIRFLO TRBL DEVICES:

N/A SETPOINT:

N/A

1.0 CAUSE(S)

1.1 Roughing Filter Dampers not fully OPEN 1.2 HEPA Filter Inlet Damper not fully CLOSED 1.3 HEPA Filter Outlet Damper not fully CLOSED 2.0 AUTOMATIC ACTION:

None 3.0 OPERATOR ACTIONS:

3.1 IF 25 Containment Fan Coil Unit is operating in low speed, THEN no further Operator action is required.

3.2 ENSURE positions of 25 Containment Fan Coil Filter Dampers on Control Console bezels.

3.3 IF damper malfunction is indicated, THEN:

A.

STOP 25 Containment Fan Coil Unit.

B.

INITIATE a NOTF IAW LS-AA-120, Issue Identification and Screening Process 3.4 REFER to Technical Specification 3.6.2.3.

Page 1 of 1 C-36

References:

Dwg. 205338, 203584

S2.OP-AR.ZZ-0003(Q)

Salem 2 Page 43 of 57 Rev. 17 ALARM C-37 37 25 CFCU WTRFLO TRBL DEVICES:

N/A SETPOINT:

N/A

1.0 CAUSE(S)

Any SW Valve misaligned with the CFCU running:

25SW58, 25 FAN COIL UNIT INLET WATER VALVE not fully OPEN 25SW72, 25 FAN COIL UNIT OUTLET WATER VALVE not fully OPEN 25SW223, 25 FAN COIL UNIT OUTLET WATER FLOW CONTROL VALVE, is CLOSED 2.0 AUTOMATIC ACTION:

None 3.0 OPERATOR ACTIONS:

3.1 CONFIRM alarm by observing flow indication on 25 CFCU bezel.

3.2 ENSURE OPEN the following valves:

A.

25SW58, 25 FAN COIL UNIT INLET WATER VALVE B.

25SW72, 25 FAN COIL UNIT OUTLET WATER VALVE 3.3 IF a valve malfunction is suspected, THEN:

A.

STOP 25 Containment Fan Coil Unit.

B.

INITIATE a NOTF IAW LS-AA-120, Issue Identification and Screening Process 3.4 REFER to Technical Specification 3.6.2.3.

Page 1 of 1 C-37

References:

Dwg. 205342, 203586

S2.OP-AR.ZZ-0003(Q)

Salem 2 Page 44 of 57 Rev. 17 ALARM C-38 38 CFCU LK DET HI M

DEVICES:

2LT730, 2LT731, 2LT732, 2LT733, 2LT734 SETPOINT:

$ 0.8 feet of water

1.0 CAUSE(S)

Any Containment Fan Coil Unit leak detector level $ 0.8 feet of water 2.0 AUTOMATIC ACTION:

None 3.0 OPERATOR ACTIONS:

3.1 DETERMINE which CFCU is causing the alarm from the Annunciator CRT:

CRT Point Description 492 CONTAINMENT FAN COIL UNIT 21 LEAK DETECTOR HIGH 493 CONTAINMENT FAN COIL UNIT 22 LEAK DETECTOR HIGH 494 CONTAINMENT FAN COIL UNIT 23 LEAK DETECTOR HIGH 495 CONTAINMENT FAN COIL UNIT 24 LEAK DETECTOR HIGH 496 CONTAINMENT FAN COIL UNIT 25 LEAK DETECTOR HIGH (Continued)

Page 1 of 2 C-38

S2.OP-AR.ZZ-0003(Q)

Salem 2 Page 45 of 57 Rev. 17 3.2 ENSURE OPEN 21-25WD50, CFCU CONDENSATE SHUTOFF, at 2RP1.

3.3 IF the alarm is due to suspected clogging of the drain line, THEN:

A.

SELECT the CFCU for LEAK DETECTION indication (LI730) at 2CC1.

B.

CLOSE the associated WD50 valve at 2RP1.

C.

WAIT until the LEAK DETECTION indication (LI730) at 2CC1 is at a maximum value to facilitate flushing any sediment from the drain line.

D.

OPEN the associated WD50 valve at 2RP1.

E.

IF the alarm condition does NOT clear, THEN INITIATE an NOTF IAW LS-AA-120, Issue Identification and Screening Process.

3.4 IF there is indication of leakage other than Service Water, THEN INITIATE leakrate IAW S2.OP-SO.RC-0004(Q),

Identifying and Measuring Leakage.

3.5 IF there is indication of Service Water leakage, THEN:

A.

STOP the affected CFCU.

CAUTION Isolating a CFCU from the control room with the SW58 and SW72 valves also isolates SW overpressure protection for the CFCU. These valves should only be used when there is a SW leak requiring immediate isolation.

B.

ISOLATE the affected CFCU IAW S2.OP-SO.SW-0005(Q),

Service Water System Operation.

C.

INITIATE a NOTF IAW LS-AA-120, Issue Identification and Screening Process.

D.

INITIATE SC.OP-DG.SW-0005, Service Water Spill Response in Containment.

3.6 REFER to Technical Specification 3.6.1.1 and 3.6.2.3.

Page 2 of 2 C-38 References Dwg. 205327, 220061, 240690

S2.OP-AR.ZZ-0003(Q)

Salem 2 Page 46 of 57 Rev. 17 ALARM C-39 39 DEVICES:

SETPOINT:

SPARE Page 1 of 1 C-39

References:

Dwg.

S2.OP-AR.ZZ-0003(Q)

Salem 2 Page 47 of 57 Rev. 17 ALARM C-40 40 DEVICES:

SETPOINT:

SPARE Page 1 of 1 C-40

References:

Dwg.

S2.OP-AR.ZZ-0003(Q)

Salem 2 Page 48 of 57 Rev. 17 ALARM C-41 41 DEVICES:

SETPOINT:

SPARE Page 1 of 1 C-41

References:

S2.OP-AR.ZZ-0003(Q)

Salem 2 Page 49 of 57 Rev. 17 ALARM C-42 42 DEVICES:

SETPOINT:

SPARE Page 1 of 1 C-42

References:

Dwg.

S2.OP-AR.ZZ-0003(Q)

Salem 2 Page 50 of 57 Rev. 17 ALARM C-43 43 DEVICES:

SETPOINT:

SPARE Page 1 of 1 C-43

References:

Dwg.

S2.OP-AR.ZZ-0003(Q)

Salem 2 Page 51 of 57 Rev. 17 ALARM C-44 44 DEVICES:

SETPOINT:

SPARE Page 1 of 1 C-44

References:

Dwg.

S2.OP-AR.ZZ-0003(Q)

Salem 2 Page 52 of 57 Rev. 17 ALARM C-45 45 DEVICES:

SETPOINT:

SPARE Page 1 of 1 C-45

References:

Dwg.

S2.OP-AR.ZZ-0003(Q)

Salem 2 Page 53 of 57 Rev. 17 ALARM C-46 46 PERSONNEL ACCESS DOOR OPEN DEVICES:

N/A SETPOINT:

N/A

1.0 CAUSE(S)

Any personnel airlock in use to or from Containment at the locations listed:

Elevation 100 Elevation 130 2.0 AUTOMATIC ACTION:

None 3.0 OPERATOR ACTIONS:

3.1 IF an authorized Containment entry is being made, THEN:

A.

RECORD Containment Airlocks and Loose Debris Inspection information IAW S2.OP-DL.ZZ-0001(Q), Control Room Logs.

B.

No further action required.

3.2 SEND Operator to ENSURE CLOSED airlock door(s).

3.3 IF unable to clear alarm, THEN:

A.

REFER to Technical Specification 3.6.1.3.

B.

INITIATE a NOTF IAW LS-AA-120, Issue Identification and Screening Process C.

PERFORM S2.OP-ST.CAN-0004(Q),

Containment Air Lock Local Leak Rate Test.

Page 1 of 1 C-46

References:

Dwg. 231096

S2.OP-AR.ZZ-0003(Q)

Salem 2 Page 54 of 57 Rev. 17 ALARM C-47 47 DEVICES:

SETPOINT:

SPARE Page 1 of 1 C-47

References:

Dwg.

S2.OP-AR.ZZ-0003(Q)

Salem 2 Page 55 of 57 Rev. 17 ALARM C-48 48 DEVICES:

SETPOINT:

SPARE Page 1 of 1 C-48

References:

Dwg.

S2.OP-AR.ZZ-0003(Q)

Salem 2 Page 56 of 57 Rev. 17 OVERHEAD ANNUNCIATORS WINDOW C REFERENCES 1.0 Plant Documents:

Technical Specifications Unit 2 Event Classification Guide

2.0 Commitments

C0551, LER 272/94-013-00

3.0 Procedures

None

4.0 PSBPs

None

5.0 Other

2EC-3228, Provide reflash capability to C-1 window ECA 80004565, OHA C-24 CBV ISOL SIGNAL PRESENT spared INPO SER 40-86, Spent Fuel Pool Leakage 2EC-1707A, Reset setpoint of LS-2067 MM S97-0095, Hydrogen Recombiner HI-KW Alarm Relay Removal S-C-SF-MDC-1800, Decay Heatup Rates and Curves 6.0 Cross-

References:

2-EOP-TRIP-1, Reactor Trip or Safety Injection S2.OP-AB.CC-0001(Q), Component Cooling Abnormality S2.OP-AB.FUEL-0002(Q), Loss of Refueling Cavity or Spent Fuel Pool Level S2.OP-AB.RC-0001(Q), Reactor Coolant System Leak.

S2.OP-AB.RCP-0001(Q), RCP Abnormality S2.OP-AB.RHR-0001(Q), Loss of RHR S2.OP-AB.RHR-0002(Q), Loss of RHR At Reduced Inventory S2.OP-AB.SF-0001(Q), Loss of Spent Fuel Pool Cooling S2.OP-AB.SW-0001(Q), Loss of Service Water Header Pressure S2.OP-AR.WG-0001(Q), Waste Disposal Gas Analyzer PNL 110 S2.OP-SO.RC-0004(Q), Identifying and Measuring Leakage S2.OP-SO.RPS-0005(Q), Placing Containment Pressure Channel In Tripped Condition S2.OP-SO.SF-0001(Q), Filling the Spent Fuel Pool S2.OP-ST.CAN-0004(Q), Containment Air Lock Local Leak Rate Test

S2.OP-AR.ZZ-0003(Q)

Salem 2 Page 57 of 57 Rev. 17

7.0 Drawings

203568, No. 1 & 2 Units-Containment Ventilation No.11 & 21 Fan-Coil Units 203570, No. 1 & 2 Units-Containment Ventilation No.11 & 21 Fan-Coil Units 203572, No. 1 & 2 Units-Containment Ventilation No.12 & 22 Fan-Coil Units 203574, No. 1 & 2 Units-Containment Ventilation No.12 & 22 Fan-Coil Units 203576, No. 1 & 2 Units-Containment Ventilation No.13 & 23 Fan-Coil Units 203578, No. 1 & 2 Units-Containment Ventilation No.13 & 23 Fan-Coil Units 203580, No. 1 & 2 Units-Containment Ventilation No.14 & 24 Fan-Coil Units 203582, No. 1 & 2 Units-Containment Ventilation No.14 & 24 Fan-Coil Units 203584, No. 1 & 2 Units-Containment Ventilation No.15 & 25 Fan-Coil Units 203586, No. 1 & 2 Units-Containment Ventilation No.15 & 25 Fan-Coil Units 203653, No. 1 & 2 Units-Containment Ventilation No.11 & 21 Hydrogen Recombiners 203654, No. 1 & 2 Units-Containment Ventilation No.12 & 22 Hydrogen Recombiners 203683, No. 1 & 2 Units-Waste Disposal System Gas Analyzer Panel 110 205234, No. 1 Unit Safety Injection 205326, No. 2 Unit Floor Drains Contaminated 205327, No. 2 Unit Equipment Vents & Drains-Contaminated 205329, No. 2 Unit-Chemical & Volume Control Boric Acid Recovery 205331, No. 2 Unit Component Cooling 205333, No. 2 Unit Spent Fuel Cooling 205338, No. 2 Unit Reactor Containment-Ventilation 205342, No. 2 Unit Service Water Nuclear Header 211514, No. 1 & 2 Units-RHR Sys. Containment Sump Level LT-939 211522, No. 1 & 2 Units-CC System Surge Tank, No.11&21 CC Hdr Press Alarms 211523, No. 1 & 2 Units-CC System Surge Tank, No.12&22 CC Hdr Press Alarms 217142, No. 1 & 2 Units-Safety Injection System Spray Additive Tk & RWST Level Alarms 220061, No. 1 & 2 Units Reactor Prot. & Process Cont. Systems Leak Detection 220972, No. 1 & 2 Units-Reactor Containment Reactor & Containment Sump Pumps 221057, No. 1 & 2 Units Reactor Protection System Safeguards Actuation Signals 222875, No. 1 & 2 Units-CVCS Gas Stripper & Boron Control Panel No.301 226513, No. 1 & 2 Units-Aux. Building 64 Waste Disposal-Boron Recycle Panel 104 227977, No. 1 & 2 Units-Control Room Area SSPS System Train A Interface Cab.32 231035, No. 1 & 2 Units-Auxiliary Building RHR No.11 & 12 Sump Pumps 231036, No. 1 & 2 Units-Auxiliary Building RHR No.13 & 14 Sump Pumps 231096, No. 1 & 2 Units-Cont Area Personnel Access Hatch indication & Alarms 231100, No. 1 & 2 Units-Spent Fuel Pit Cooling Spent Fuel Pit Level & Temperature 232015, No. 1 & 2 Units-Control Room Area SSPS System Train A Output Test 232016, No. 1 & 2 Units-Control Room Area SSPS Train A Output Test 240690, No. 2 Unit Equipment Vents & Drains Contaminated 240698, No. 2 Unit Sump and Flood Pumps-Contaminated 252310, No. 1 & 2 Units-Containment Ventilation Hydrogen Monitoring System