Text

October 26, 2010 Mr. Robert J. Agasie Reactor Director Nuclear Reactor Laboratory Room 130 Mechanical Engineering Building 1513 University Avenue Madison, WI 53706-1572

SUBJECT:

UNIVERSITY OF WISCONSIN - REQUEST FOR ADDITIONAL INFORMATION REGARDING THE LICENSE RENEWAL FOR THE UNIVERSITY OF WISCONSIN NUCLEAR REACTOR (TAC NO. ME1585)

Dear Mr. Agasie:

We are continuing our review of your application for renewal of Facility Operating License No.

R-74, Docket No. 50-156 for the University of Wisconsin. The application was submitted on May 9, 2000, as supplemented by letters dated October 17, 2008; June 16, 2010 (two letters);

July 8, 2010, and August 11, 2010.

During our review of the proposed technical specifications, a question has arisen for which we require additional information and clarification. Please provide a response to the enclosed request for additional information within 30 days of the date on this letter.

In accordance with Title 10 of the Code of Federal Regulations, Section 50.30(b), your response must be executed in a signed original under oath or affirmation. Following receipt of the requested information we will continue our evaluation of your application. If you have any questions regarding this review, please contact me at 301-415-0893.

Sincerely,

/RA/

Geoffrey Wertz, Project Manager Research and Test Reactors Projects Branch Division of Policy and Rulemaking Office of Nuclear Reactor Regulation Docket No. 50-156 License No. R-95

Enclosure:

As stated Cc w/encl: See next page

ML102990282 *Concurrence via e-mail NRR-088 OFFICE PRLB: PM*

PRLB: LA PRLB: PM PRLB: PM*

NAME GWertz GLappert JQuichocho GWertz DATE 10/26/2010 10/26/2010 10/26/2010 10/26/2010

University of Wisconsin Docket No. 50-156 cc:

Mayor of Madison City Hall 210 Martin Luther King, Jr. Boulevard, Room 403 Madison, Wisconsin 53703 Chairman, Public Service Commission of Wisconsin 610 North Whitney Way P.O. Box 7854 Madison, WI 53707-7854 Manager Radiation Protection Section Division of Public Health Dept of Health and Family Services P.O. Box 2659 Madison, WI 53701-2659 Test, Research, and Training Reactor Newsletter University of Florida 202 Nuclear Sciences Center Gainesville, FL 32611 Victor Goretsky Assistant Director & Radiation Safety Officer Department Environmental Health & Safety 530 Environmental Protection And Safety Bldg 30 N Murray St Madison, WI 53715 Eric C Woolstenhulme Idaho National Laboratory P.O. Box 1625, Idaho Falls, ID 83415-3740

Enclosure OFFICE OF NUCLEAR REACTOR REGULATION REQUEST FOR ADDITIONAL INFORMATION UNIVERSITY OF WISCONSIN FACILITY OPERTING LICENSE NO. R-74 DOCKET NO. 50-156 The U. S. Nuclear Regulatory Commission (NRC) staff is continuing the review of your application for renewal of Facility Operating License No. R-74, dated May 9, 2000, as supplemented by letters dated October 17, 2008; June 16, 2010 (two letters); July 8, 2010, and August 11, 2010. During our review of the proposed technical specifications, a question has arisen for which we need additional information and clarification. Please address and provide the requested information to the following:

Proposed TS 3.2.1, Operable Control Rods, allows operation with a minimum of three control elements with scram capability. However, the evaluation in the Safety Analysis Report for the conversion of the reactor from high enriched uranium to low enriched uranium fuel shows that pin power and peaking factors (and the resulting thermal-hydraulic calculations) were determined with the control blades banked. Please provide an analysis that shows that reactor operation is acceptable with control elements allowed by proposed TS 3.2.1.