Official Transcript of Proceedings NUCLEAR REGULATORY COMMISSION

Title:

10 CFR 2.206 Petition RE Pilgrim Nuclear Power Plant Docket Number:

(n/a)

Location:

(telephone conference)

Date:

Monday, August 9, 2010 Work Order No.:

NRC-385 Pages 1-34 Edited by Rich Guzman, NRC Petition Manager NEAL R. GROSS AND CO., INC.

Court Reporters and Transcribers 1323 Rhode Island Avenue, N.W.

Washington, D.C. 20005 (202) 234-4433

NEAL R. GROSS COURT REPORTERS AND TRANSCRIBERS 1323 RHODE ISLAND AVE., N.W.

(202) 234-4433 WASHINGTON, D.C. 20005-3701 www.nealrgross.com 1

1

NEAL R. GROSS COURT REPORTERS AND TRANSCRIBERS 1323 RHODE ISLAND AVE., N.W.

(202) 234-4433 WASHINGTON, D.C. 20005-3701 www.nealrgross.com 1

UNITED STATES OF AMERICA 1

NUCLEAR REGULATORY COMMISSION 2

+ + + + +

3 10 CFR 2.206 PETITION REVIEW BOARD (PRB) 4 CONFERENCE CALL 5

RE 6

PILGRIM NUCLEAR POWER PLANT 7

+ + + + +

8 MONDAY 9

AUGUST 9, 2010 10

+ + + + +

11 The conference call was held, Theodore 12 Quay, Chairperson of the Petition Review Board, 13 presiding.

14 PETITIONER: MARY ELIZABETH LAMPERT 15 PETITION REVIEW BOARD MEMBERS:

16 THEODORE QUAY, Deputy Director 17 Office of Nuclear Reactor Regulation 18 RICHARD GUZMAN, Petition Manager for 2.206 petition 19 TANYA MENSAH, Petition Review Board Coordinator 20 21 22 23 24 NRC HEADQUARTERS STAFF:

25

NEAL R. GROSS COURT REPORTERS AND TRANSCRIBERS 1323 RHODE ISLAND AVE., N.W.

(202) 234-4433 WASHINGTON, D.C. 20005-3701 www.nealrgross.com 2

SHELDON

STUCHELL, Office of Nuclear Reactor 1

Regulations, Licensing Process Branch 2

MATTHEW MCCONNELL, Office of Nuclear Reactor 3

Regulations, Electrical Engineering Branch 4

DOUGLAS DODSON, NRC Region 1, Division of Reactor 5

Projects 6

LAURA GOLDEN, Senior Attorney, Office of General 7

Counsel.

8 9

10 11 12 13 14 15 16 17 18 19 20 21 22 23

NEAL R. GROSS COURT REPORTERS AND TRANSCRIBERS 1323 RHODE ISLAND AVE., N.W.

(202) 234-4433 WASHINGTON, D.C. 20005-3701 www.nealrgross.com 3

P R O C E E D I N G S 1

(2:01:57 p.m.)

2 MR. GUZMAN: I'm going to kickoff the 3

discussion for today. And I guess before we get into 4

introductions, I'll just say a couple of introductory 5

remarks.

6 My name is Rich Guzman, Project Manager in 7

the Office of Nuclear Reactor Regulation, or NRR. I'd 8

like to thank everybody for their coordination 9

efforts, and attending this meeting.

10 The purpose of today's conference call is 11 to allow the Petitioner, Mary Lampert, to address the 12 Petition Review Board regarding the 2.206 Petition 13 dated July 19th, 2010, which is titled "Pilgrim Watch 14 2.206 Petition Regarding Inadequacy of Entergy's 15 Management of Non-Environmentally Qualified 16 Inaccessible Cables and Wiring at Pilgrim Station." I 17 am the Petition Manager for the Petition.

18 MS.

LAMPERT: And,

also, you'll be 19 discussing the Supplement, I presume.

20 MR.

GUZMAN: We did receive the 21 Supplement, Mary Elizabeth. We have distributed it 22 amongst the group here. The Petition Review Board, or 23 PRB Chairman is Ted Quay. And before I briefly go 24 over the agenda, if we can go through introductions.

25

NEAL R. GROSS COURT REPORTERS AND TRANSCRIBERS 1323 RHODE ISLAND AVE., N.W.

(202) 234-4433 WASHINGTON, D.C. 20005-3701 www.nealrgross.com 4

So, I'd like to open this meeting, we'll start at our 1

end of the room of the bridge line. I ask that you 2

clearly state your name, your position, and your 3

office or organization for the record. So, I'll start 4

off. Again, it's Rich Guzman, Project Manager in the 5

Office of NRR.

6 MR. McCONNELL: I am Matthew McConnell.

7 I'm a Senior Electrical Engineer in NRR.

8 MR.

STUCHELL: I'm Sheldon

Stuchell, 9

Senior Project Manager in the Office of NRR.

10 MS. UTTAL: Susan Uttal, Senior Attorney, 11 OGC. I'm observing.

12 MS. GOLDEN: Laura Golden, Attorney, OGC.

13 CHAIR QUAY: Ted Quay, Office of Nuclear 14 Reactor Regulation.

15 MS. REGNER: Lisa Regner, Senior Project 16 Manager.

17 MS. POPOVA: I'm Alex Popova, and I'm from 18 NRR, just observing.

19 MR. GUZMAN: And that's introductions here 20 at NRC Headquarters. And, at the time, are there any 21 NRC participants from Headquarters on the Bridge Line?

22 MS. MENSAH: This is Tanya Mensah. I'm 23 the 2.206 Coordinator. And before I pass it on, I 24 just wanted to clarify that the meeting is being 25

NEAL R. GROSS COURT REPORTERS AND TRANSCRIBERS 1323 RHODE ISLAND AVE., N.W.

(202) 234-4433 WASHINGTON, D.C. 20005-3701 www.nealrgross.com 5

recorded by the NRC Operations Center, and it will be 1

transcribed, and the transcript will become a

2 supplement to the Petition. And the transcript will 3

also be made publicly available.

4 MS. LAMPERT: How long will it take to get 5

on ADAMS?

6 MS. MENSAH: As soon as Rich Guzman is 7

provided with the transcript by the court reporter.

8 He sends it out for comment so everyone can clarify 9

any - if there are any errors, or anything, as far as 10 typos for names. Generally, he can put it in ADAMS 11 immediately, it just depends on how fast everyone can 12 review it. You'll receive a copy of the transcript, 13 as well, but it will be public.

14 MR. GUZMAN: Mary, I expect it to be 15 within the week, but I'll certainly notify you once we 16 get it through the transcription service. Is there 17 anyone else, Tanya? I guess that -- well, actually, 18 from the Region, you can go through.

19 MR. DODSON: Hi, Doug Dodson, Project 20 Engineer, Region I.

21 MR. GUZMAN: All right. Are there any 22 representatives for the licensee on the phone?

23 MR. LYNCH: This is Joe Lynch, Licensing 24 Manager, Entergy/Pilgrim.

25

NEAL R. GROSS COURT REPORTERS AND TRANSCRIBERS 1323 RHODE ISLAND AVE., N.W.

(202) 234-4433 WASHINGTON, D.C. 20005-3701 www.nealrgross.com 6

MS. CHOE: And this is Jeannie Choe from 1

Entergy Legal.

2 MR. GUZMAN: Okay. Ms. Lampert, if you 3

could just introduce

yourself, and also your 4

colleagues or associates that plan on supporting the 5

presentation today.

6 MS. LAMPERT: Mary Lampert, Pilgrim Watch 7

Director, and why doesn't everybody who's on introduce 8

themselves? I think that would be easier.

9 MR. BLANCH: Yes. My name is Paul Blanch.

10 I'm an energy consultant, I'm an electrical engineer.

11 MS. LAMPERT: Serving as an expert witness 12 for us.

13 MR. GUNTER: This is Paul Gunter, Beyond 14 Nuclear in Tacoma Park, Maryland. I'm just listening 15 in, and I will be on mute.

16 MS. CHIN: This is Rebecca Chin. I Co-17 Chair the Duxbury Nuclear Advisory Committee, and we 18 join the Petitioner in this case. And I will mostly 19 be observing and listening.

20 MR. GUZMAN: Okay. Is there anyone else 21 for the public on the bridge line?

22 Okay. I'll go ahead and provide a brief 23 overview of the agenda. Again, the meeting is 24 scheduled from 2:00 to 3:00 p.m. Eastern Time. And as 25

NEAL R. GROSS COURT REPORTERS AND TRANSCRIBERS 1323 RHODE ISLAND AVE., N.W.

(202) 234-4433 WASHINGTON, D.C. 20005-3701 www.nealrgross.com 7

Ms. Mensah mentioned, it is recorded by the NRC 1

Operations Center, and will be transcribed by a court 2

reporter.

3 Following my introduction, I'll turn it 4

over to the PRB Chairman for his introduction. And 5

then followed by Ms. Lampert's presentation, which is 6

scheduled to be about 30-35 minutes, and finally hand 7

it back over to the PRB Chairman, who will conclude 8

the meeting with closing remarks.

9 I'd like to emphasize that we each need to 10 speak clearly and loudly to make sure that the court 11 reporter can accurately transcribe this meeting. And 12 if you do have something that you would like to say, 13 please first state your name for the record. And, Mr.

14 Gunter, you mentioned you were going to mute. For 15 those dialing into the meeting, if you could remember 16 to mute your phones to minimize any background noise.

17 If you do not have a mute button, this can be done by 18 pressing the keys *6, and then to unmute press *6 keys 19 again. Thanks.

20 So, at this time, I'll turn it over to the 21 PRB Chairman, Ted Quay.

22 CHAIR QUAY: Good afternoon. Welcome to 23 this meeting regarding the 2.206 petition submitted by 24 Mary Lampert. I'd like to share, first, some 25

NEAL R. GROSS COURT REPORTERS AND TRANSCRIBERS 1323 RHODE ISLAND AVE., N.W.

(202) 234-4433 WASHINGTON, D.C. 20005-3701 www.nealrgross.com 8

background information on our process.

1 Section 2.206 of Title 10 of the Code of 2

Federal Regulations describes the petition process, 3

the primary mechanism for the public to request 4

enforcement action by the NRC in a public process.

5 This process permits anyone to petition NRC to take 6

enforcement-type action related to NRC licensees, or 7

licensed activities.

8 Depending on the results of its 9

evaluation, NRC could modify, suspend, or revoke an 10 NRC-issued license, or take any other appropriate 11 enforcement action to resolve a problem. The NRC 12 staff's guidance for the disposition of 2.206 petition 13 requests is in Management Directive 8.11, which is 14 publicly available.

15 The purpose of today's meeting is to give 16 the Petitioner an opportunity to provide any 17 additional explanation or support for the petition 18 before the Petition Review Board's initial 19 consideration and recommendation. This meeting is not 20 a hearing, nor is it an opportunity for the Petitioner 21 to question or examine the Petition Review Board on 22 the merits, or the issues presented in the petition 23 request. No decision regarding the merits of this 24 petition will be made at this meeting.

25

NEAL R. GROSS COURT REPORTERS AND TRANSCRIBERS 1323 RHODE ISLAND AVE., N.W.

(202) 234-4433 WASHINGTON, D.C. 20005-3701 www.nealrgross.com 9

Following this

meeting, the Petition 1

Review Board will conduct its internal deliberations.

2 The outcome of this internal meeting will be 3

discussed with the Petitioner. The Petition Review 4

Board typically consists of a Chairman, usually a 5

Manager at the Senior Executive Service Level at the 6

NRC, and has a Petition Manager, and a Petition Review 7

Board Coordinator. Other members of the Board are 8

determined by the NRC staff based on the content of 9

the information in the petition request.

10 At this time, I would like to introduce 11 the Board. I am Ted Quay, the Petition Review Board 12 Chairman. Rich Guzman is the Petition Manager for the 13 petition under discussion today. Tanya Mensah is the 14 Office Petition Review Board Coordinator. Our 15 technical staff includes Sheldon Stuchell from the 16 Office of Nuclear Reactor Regulations, Licensing 17 Process Branch; Matt McConnell from the Office of 18 Nuclear Reactor Regulations, Electrical Engineering 19 Branch; Douglas Dodson from NRC Region I, Division of 20 Reactor Projects. We also obtain advice from our 21 Office of General Counsel, represented by Laura 22 Golden.

23 As described in our process, the NRC staff 24 may ask clarifying questions in order to better 25

NEAL R. GROSS COURT REPORTERS AND TRANSCRIBERS 1323 RHODE ISLAND AVE., N.W.

(202) 234-4433 WASHINGTON, D.C. 20005-3701 www.nealrgross.com 10 understand the Petitioner's presentation, and to reach 1

a reasoned decision whether to accept or reject the 2

Petitioner's request for review under the 2.206 3

process.

4 I would like to summarize the scope of the 5

petition under consideration, and the NRC activities 6

to-date. On July 19th, 2010, Ms. Lampert submitted to 7

the NRC a petition under 2.206 regarding Entergy's 8

management of non-environmentally qualified 9

inaccessible cables and wirings in the Pilgrim 10 Station. In this request, Ms. Lampert requested the 11 NRC to issue a demand for information and order for 12 Entergy to demonstrate that all inaccessible cables at 13 Pilgrim Nuclear Power

Station, referred to 14 subsequently as Pilgrim, are capable of performing 15 their intended function, be it safety or non-safety 16 related, certify that all cables inaccessible or 17 accessible have been identified as to their location, 18 age, repair history to both the NRC and public at 19 Pilgrim. And (B), monitored by the licensee prior to 20 continued operation to demonstrate that the cables can 21 perform their designed functions. And (C), includes a 22 monitoring program that incorporates various DOE and 23 EPRI guidelines, and NRC generic communications.

24 Also, asked that commits to verifying the licensee 25

NEAL R. GROSS COURT REPORTERS AND TRANSCRIBERS 1323 RHODE ISLAND AVE., N.W.

(202) 234-4433 WASHINGTON, D.C. 20005-3701 www.nealrgross.com 11 renewal period that Entergy's implementation through 1

the routine baseline inspections and commits to a 2

timely upgrade of regulatory guidance to provide 3

guidance for maintaining the cable qualification and 4

verification that the cables can perform their design 5

functions.

6 As the basis for this request, Ms. Lampert 7

states that Pilgrim, like all other nuclear power 8

plants, have thousands of submerged/underground 9

internal electric wiring and cables throughout the 10 plant that support safety and non-safety systems.

11 These systems are dependent upon electrical power to 12 perform its function to prevent major accidents.

13 The Petitioner is also concerned that the 14 loss of electrical power will increase the likelihood 15 of major radioactive releases to the environment.

16 Also, the Petitioner states that Pilgrim has a long 17 history of cables being submerged and/or wedded with 18 no verification of long-term operability of these 19 cables.

20 In addition, the Petitioner states that 21 Entergy and the NRC have ignored regulations that 22 provide reasonable assurance that these wires/cables 23 will function when required during reactor 24 emergencies.

25

NEAL R. GROSS COURT REPORTERS AND TRANSCRIBERS 1323 RHODE ISLAND AVE., N.W.

(202) 234-4433 WASHINGTON, D.C. 20005-3701 www.nealrgross.com 12 As a reminder for the phone participants, 1

please identify yourself if you make any remarks, as 2

this will help us in the preparation of the meeting 3

transcript that will be made publicly available.

4 Thank you.

5 At this point, I'm going to turn it over 6

to Ms. Lampert.

7 MS.

LAMPERT: Yes.

Good afternoon.

8 Number

one, at this
time, does NRC see any 9

shortcomings in the petition that would provide a 10 basis for its rejection? And, if so, could you please 11 enumerate shortcomings you see at this point. That's 12 a procedural question.

13 CHAIR QUAY: We're not going to do that, 14 because we're here to gather information from you 15 today.

16 MS. LAMPERT: Okay. Next point is, you 17 did a good job outlining the scope, and what we are 18 saying is that Pilgrim is currently in violation of 19 regulations today. And that the Aging Management 20 Program for the license renewal period does not 21 provide reasonable assurance. And, as importantly, 22 neither NRC or Entergy know the extent of violations, 23 because the necessary information that we requested is 24 not there. In particular, we understand that non-EQ 25

NEAL R. GROSS COURT REPORTERS AND TRANSCRIBERS 1323 RHODE ISLAND AVE., N.W.

(202) 234-4433 WASHINGTON, D.C. 20005-3701 www.nealrgross.com 13 inaccessible cables, and when we said cables and 1

wiring, we were including, and I want to make that 2

clear, cable splices and connectors in the package, so 3

it's the cable, cable splice, and connectors that is 4

the focus of this petition. That they are potentially 5

exposed to submergence or moisture; therefore, it's 6

very important for NRC and the public to know the 7

location of every single component under scope to 8

determine the probability of moisture.

9 This is particularly important at Pilgrim 10 because they have not performed an updated hydro geo 11 study using -- investigating the subsurface since the 12 pre-operational Dames & Moore study in 1967. This is 13 a concern of the Massachusetts Department of Public 14 Health, a concern in a contention brought forward for 15 license renewal on buried components, and a large 16 concern here.

17 There has been a change in climate 18 affecting tidal surges, and it's very important, as 19 the Brookhaven report pointed out at 4-18, that there 20 be real specific information on water table depth, and 21 how the water table is affected by tides, by the Bay, 22 by storms, by rain, by snow. Pilgrim is adjacent to 23 Cape Cod Bay, and moisture is a clear and present 24 issue.

25

NEAL R. GROSS COURT REPORTERS AND TRANSCRIBERS 1323 RHODE ISLAND AVE., N.W.

(202) 234-4433 WASHINGTON, D.C. 20005-3701 www.nealrgross.com 14 Also, we would like to know and the age 1

provided of all of these components, because the 2

Brookhaven report pointed out that they are 3

experiencing problems short of their 40-year license, 4

as early as 11 to 20 years, and so we want to know are 5

these original cables, how much has been replaced or 6

added, what the material is of these components, are 7

they qualified for submerged operation. Brookhaven 8

said they should be specifically procured as submarine 9

cables, and we would like to know a detailed 10 assessment of what the monitoring and testing 11 inspection history has been, and exactly what is 12 projected for the future.

13 For example, in the inspection report 14 which was provided in the supplement, we saw that 15 there are three samples of manholes, period. We would 16 like to know in that, for example, what percent that 17 is of the number of manholes that would be applicable.

18 Are there 30, are there 40, are there five? How many 19 are there? So, to understand how representative that 20 sample was.

21 We were told -- we read in that report 22 that one of the manholes was periodically found 23 submerged or partially submerged, and the other two 24 were always found submerged. And, more important, 25

NEAL R. GROSS COURT REPORTERS AND TRANSCRIBERS 1323 RHODE ISLAND AVE., N.W.

(202) 234-4433 WASHINGTON, D.C. 20005-3701 www.nealrgross.com 15 they identified that this was an ongoing problem, and 1

that Entergy has not been following the protocol. So, 2

I could go on, but I'd like to turn this over at this 3

point to Paul Blanch, who has recently retired from 4

the Millstone, a Nuclear Engineer specializing in 5

electrical engineering. So, Paul, why don't you 6

carry, and then I'll chime in, as others might also 7

want to do.

8 MR. BLANCH: Thank you, Mary. This is 9

Paul Blanch, again. Ted, it's been a few years since 10 we've had any conversations, I think, and Sheldon, we 11 talked last week about the submerging topic.

12 What I'd first like to do is, I wasn't 13 totally pleased about one of the responses the NRC 14 staff provided. And my concern is, did we meet the 15 legal threshold, or did we omit anything from the 16 requirements on the 2.206 petition. Now, I've read 17 Management Directive 8.11, I've read 2.206, and I just 18 wanted to make sure that there's not a shortcoming 19 within the verbiage of the petition and the 20 supplements that will say well, you forgot to do this.

21 I want to make sure that from your perspective, 22 there's not a legal shortcoming in the submission 23 that's just going to throw it out because every I is 24 not dotted, and T crossed. And I think that's a 25

NEAL R. GROSS COURT REPORTERS AND TRANSCRIBERS 1323 RHODE ISLAND AVE., N.W.

(202) 234-4433 WASHINGTON, D.C. 20005-3701 www.nealrgross.com 16 reasonable request at this time.

1 MS. MENSAH: This is Tanya Mensah. I'm 2

the 2.206 Coordinator. I think your question is fair, 3

and you're actually ahead of us. There are two 4

opportunities that are offered for the Petitioner to 5

address the PRB. The first is before the Petition 6

Review Board even meets internally to address that 7

question.

So, at this point we're gathering 8

information from the Petitioner. We have the actual 9

petition, the supplement, and when we meet internally, 10 we're going to be looking at the criteria to determine 11 that, as well as if it meets the criteria for review, 12 or the criteria for rejection. So, at this point, I 13 don't think we can answer that question, because Ms.

14 Lampert indicated that she wanted to address the 15 Petition Review Board before we met internally to 16 address that.

17 MR. BLANCH: Okay. I was just wondering 18 whether there were any clear shortcomings, and from my 19 review in dealing with this Agency for many years, it 20 seems to be complete.

21 But, anyway, I would like to just start o 22 page 1 of the July 19th petition. I assume everyone's 23 got a copy. And it starts out in Paragraph 1, 24 "Inaccessible Cables." And I want to make sure that 25

NEAL R. GROSS COURT REPORTERS AND TRANSCRIBERS 1323 RHODE ISLAND AVE., N.W.

(202) 234-4433 WASHINGTON, D.C. 20005-3701 www.nealrgross.com 17 inaccessible cables is understood to mean the same 1

thing. It's those cables that are not readily 2

viewable by a normal person on his normal rounds.

3 This does not only mean buried cables, but it could be 4

cables within conduit, within buildings, and so and so 5

forth. So, it goes beyond just those cables that are 6

buried underground. It's inaccessible cable, and 7

these are cables that are, again, primarily covered 8

under 10 CFR Part 54, and 10 CFR 50.65, which is the 9

Maintenance Rule. And I want to make sure it's very 10 clear, because the Gall report is not very clear that 11 it covers high voltage, medium, low voltage, power 12 cables, control cables, and instrumentation cables, 13 and indicating cables for those systems that are 14 covered either under Part 54 or the Maintenance Rule.

15 And the second -- the first line of the 16 second paragraph, that "The NRC certifies," I'm not 17 sure certifies is the right word here, but I think the 18 intent here was to demonstrate that the plant is in 19 compliance with the Federal Regulations stated in 10 20 CFR.

21 Third line up from the bottom, there's 22 reference to "Regulatory Guidance." The intent there, 23 Mary, correct me if I'm wrong, it says, "Timely 24 upgrade to Regulatory Guidance." It's really meant to 25

NEAL R. GROSS COURT REPORTERS AND TRANSCRIBERS 1323 RHODE ISLAND AVE., N.W.

(202) 234-4433 WASHINGTON, D.C. 20005-3701 www.nealrgross.com 18 mean upgrades to demonstrate compliance with 1

Regulatory Requirements. We're talking requirements 2

here, not guidance.

3 MS. LAMPERT: Yes, that's correct.

4 MR. BLANCH: Guidance is not enforceable, 5

only regulations are enforceable.

6 Switching over to page 3, the bottom of 7

page 3 under "Degradation of conduits and submerged 8

cables," I want to makes sure where it says "moist or 9

submerged environment," that the Staff takes into 10 consideration that it's not only moist and/or 11 submerged, that it could contain very, very high 12 concentration of salts, which is different from a lot 13 of plants that are located inland, Pilgrim, Seabrook, 14 Millstone, we all know that they're in a very 15 chemically corrosive environment, which makes them 16 different from somewhere like Palo Verde, or Wolfe 17 Creek.

18 Footnote Five at the end of page 3, where 19 it says, "General Design Criteria 4 within Appendix A 20 and 10 CFR 50." Now, Appendix B has to be included in 21 there, and it's intended to be included. Now, it says 22 in here, "General Design Criterion 4," and I know the 23 NRC has switched around the criterion, and I know it 24 normally refers to Criterion 4, but the NRC has this 25

NEAL R. GROSS COURT REPORTERS AND TRANSCRIBERS 1323 RHODE ISLAND AVE., N.W.

(202) 234-4433 WASHINGTON, D.C. 20005-3701 www.nealrgross.com 19 interpretation that some plants prior to July 17th of 1

1971. But whatever General Design Criteria it is, is 2

the one that's intended here. It's General Design 3

Criteria now as stated in Appendix A to 10 CFR 50.

4 The applicability of 50.49 is in question.

5 I

believe that is covered by Environmental 6

Qualification, but I

don't think that we're 7

questioning, Mary, correct me if I'm wrong, 50.49, 8

which is the Environmental Qualification Rule. We're 9

talking about non-environmentally qualified cables.

10 I'm just going through this. Again, as 11 Mary said

before, we said
wires, cables, but 12 connections, splices, and any other sealant material 13 that is used in connection of cables that are 14 inaccessible.

15 I'm on page 5 now. At the top of page 5, 16 the first full paragraph, it starts out, "The age and 17 degradation of wires is commonly the result of 18 deterioration of wiring insulation." There are 19 different aging mechanisms here, and one of the aging 20 mechanisms is just environmental exposure of the 21 insulation to the environment, whether it be just 22 normal environment, or moist, or wet, or salt. But 23 there's also another aspect of this that has to be 24 considered, that there's another aging mechanism, and 25

NEAL R. GROSS COURT REPORTERS AND TRANSCRIBERS 1323 RHODE ISLAND AVE., N.W.

(202) 234-4433 WASHINGTON, D.C. 20005-3701 www.nealrgross.com 20 I Sheldon and I discussed this in a conference call 1

last week, and that is when cables are energized and 2

carrying large amounts of current, there's a heating 3

factor that actually accelerates aging, sometimes 4

referred to as Ohmic Heating, O-H-M-I-C, or I Square R 5

Losses. Heating due to the current passing through 6

the wire, which is a different mechanism.

7 Let me see. I'm going through this.

8 Okay. The NRC typically responds -- I'm on page 6 now 9

under Item 14. And this is what I find totally 10 unsatisfactory, as far as a resolution to a regulatory 11 problem. If we look at number 14 it says, "The NRC 12 made its Information Notice 2002, 12 submerged 13 electrical cables they identified at Oyster Creek, 14 Pilgrim, Brunswick, Davis-Besse." Sheldon and I 15 discussed this at a conference call last week. I have 16 problem with the issuance of Regulatory Guides, 17 Information Notices, and any other transmissions of 18 NRC documents that don't require compliance, or 19 demonstrate incompliance with regulations.

20 We've living with regulations, and I just 21 found out today that the NRC issued an Information 22 Notice, and I think it was Information Notice 2010-12 23 that had to do with a containment. And it's an 24 Information Notice, like they put out on electrical 25

NEAL R. GROSS COURT REPORTERS AND TRANSCRIBERS 1323 RHODE ISLAND AVE., N.W.

(202) 234-4433 WASHINGTON, D.C. 20005-3701 www.nealrgross.com 21 cables, "This Information Notice is for information 1

purposes only, requires no response, and requires no 2

action." An Information or a Regulatory Guide to 3

solve a regulatory problem is unsatisfactory. These 4

plants need to be in compliance with the regulations, 5

with all the regulations that are applicable. And if 6

they're not in compliance, they specifically need an 7

exemption under 50.12 to that particular requirement.

8 Information Notices, Regulatory Guides, Bulletins 9

unless they require compliance, or specify compliance 10 with a particular regulation may not, necessarily, do 11 the trick.

12 So, the key here -- the key of all these 13 issues is the NRC has a job to do, and its job is to 14 assure that these plants are compliant with 15 regulations. And for the NRC to state that the risk 16 of these cables, or any other system is low because 17 its probability of being needed is, essentially, not 18 regulatory-based, we don't have risk-based regulations 19 at this time. Maybe in the future, we will. But when 20 the NRC cites in a non-cited violation like at 21

Vermont, where their non-compliance for the 22 regulation, they cannot -- they don't have, as far as 23 I'm concerned that I'm aware of, any regulatory basis 24 without an exemption to allow that plant to continue 25

NEAL R. GROSS COURT REPORTERS AND TRANSCRIBERS 1323 RHODE ISLAND AVE., N.W.

(202) 234-4433 WASHINGTON, D.C. 20005-3701 www.nealrgross.com 22 to operate without compliance with the regulations.

1 MS. LAMPERT: And there's also a fine that 2

should be kicked in. When they're not -- when they're 3

found not in compliance with the regulations, then 4

there's a clause for a fine, so many dollars a day 5

until they get into compliance. And that certainly is 6

an incentive for the licensee to provide the safety 7

that the public deserves, and that the regulations aim 8

to assure. Go on, Paul.

9 MR. BLANCH: Yes. And, again, I'm still 10 on page 6 of the original petition, and I look at the 11 next paragraph where it starts

out, "The NRC 12 inspection reports for the last 10 years identified 13 cable performance." Now here's the NRC, itself, 14 identifying violation of regulations, and they're 15 doing nothing. They give them a slap on the wrist, 16 and say you're a bad boy. We're going to give you a 17 green non-cited violation like they did at Vermont.

18 They've done it at Pilgrim, they've done it at every 19 plant. There is no incentive for a licensee to take 20 any action to fix any problem if all it receives is a 21 green non-cited violate.

22 The NRC has to do its job and enforce 23 those regulations, or change the regulations.

24 Actually, you said -

25

NEAL R. GROSS COURT REPORTERS AND TRANSCRIBERS 1323 RHODE ISLAND AVE., N.W.

(202) 234-4433 WASHINGTON, D.C. 20005-3701 www.nealrgross.com 23 MS.

LAMPERT: Yes.

I said in our 1

supplement there was a prime example that they were 2

given a green, and some gobbledygook on -- to justify 3

the green.

4 MR. BLANCH: Yes. I'm switching over now 5

to page 7. And under number 17, it's non-EEQ 6

inaccessible medium voltage cable." Now, here's an 7

example. This is probably the grossest example I've 8

seen of NRC accepting NEI proposed systems.

9 It says at the bottom of 17, or the first 10 paragraph of 17, "Significant voltage exposure is 11 defined as being subject to a system voltage for more 12 than 25 percent of the time." This is the most 13 ludicrous statement that has been accepted by the NRC 14 as I've ever seen in my life. We have emergency 15 motors, valves, pumps, generators that are all 16 operating less than 25 percent of the time. So, what 17 this paragraph is saying is, we are only going to test 18 those cables that are energized more than 25 percent 19 of the time. What this paragraph is saying is, I 20 don't have to ever test any of the emergency cables 21 that are only used in an emergency. This is 22 incredible that I see that in a license renewal 23 application, and then it gets accepted by the NRC that 24 it's okay. It's like saying I don't have to test my 25

NEAL R. GROSS COURT REPORTERS AND TRANSCRIBERS 1323 RHODE ISLAND AVE., N.W.

(202) 234-4433 WASHINGTON, D.C. 20005-3701 www.nealrgross.com 24 brake lines, or visually inspect them because they're 1

only used 1 percent of the time; therefore, they're 2

exempt. So, when the NRC can accept a program where 3

you don't have to test cables because they're used 4

less than 25 percent of the time is not -- the NRC is 5

not performing its proper regulatory function.

6 Also, in the LRA for Pilgrim, there are no 7

programs for low-voltage cables. This is anything 8

under, I'm not sure how low-voltage is defined, but 9

it's either under 2,000 or 1,000 volts, so this 10 excludes all those safety-related cables that are less 11 than either 1,000 or 2,000. And this is most of the 12 motor-operated valves, and it may be some of the 13 pumps, and control systems. That needs to be 14 resolved.

15 On the top of page 8, it says, "A 16 representative sample of accessible insulated cables."

17 That is, to me, a meaningless statement. How do we 18 assure that it's a representative sample? Again, the 19 LRA is referring to Section -- to an EPRI document, TR 20 109619, not totally familiar with that. I'm not 21 totally assured that it will detect degraded cables.

22 It's the NRC's responsibility to assure that these 23 cables can be detected.

24 I mean, I can go on, and on. I think the 25

NEAL R. GROSS COURT REPORTERS AND TRANSCRIBERS 1323 RHODE ISLAND AVE., N.W.

(202) 234-4433 WASHINGTON, D.C. 20005-3701 www.nealrgross.com 25 petition was put together very well. The Sandia 1

Report 960344 is a reasonable program. On page 10, 2

again, I just -- it stated that Pilgrim has no program 3

whatsoever for low-voltage cables, however they're 4

defined. A lot of this -- let's see.

5 Again, I've got a comment, it just 6

reinforces a comment I made before. Again, accessible 7

has got to mean everything that is not visible. Okay.

8 Well, again, Mary says there's no reason to believe 9

that accessible cables were representative of 10 inaccessible cables. That is an absolute true 11 statement, because accessible cables will not be 12 submerged in water, so evaluating accessible cables, 13 which are not involved, submerged in water or 14 moisture, is not representative.

15

Again, Paragraph 21, "Pilgrim should 16 operate in compliance with Federal Regulations, or not 17 at all." That is a stronger statement there. We have 18 regulations that were approved by Congress, they're 19 approved through a Rulemaking process, and the plants 20 have to operate within regulations.

21 Paragraph 22

says, "Therefore, we 22 respectfully request that the NRC certifies,"

23 certifies is not really something I think that the NRC 24 does, but that it identifies and issues some type of 25

NEAL R. GROSS COURT REPORTERS AND TRANSCRIBERS 1323 RHODE ISLAND AVE., N.W.

(202) 234-4433 WASHINGTON, D.C. 20005-3701 www.nealrgross.com 26 SER that says these cables are capable of performing 1

their function during an accident.

2 MS. LAMPERT: Yes. Well, let me just add 3

right there, this is Mary on the telephone, that as 4

far as monitoring, inspecting, testing, let's remember 5

we're focusing on two parties, focusing on the 6

licensee doing that, and being required to, and 7

demonstrating they have, and that the NRC also 8

monitors, inspects, tests, so there is oversight, and 9

we cannot have a situation where the NRC, essentially, 10 takes the word of, or reads some report, and that's 11 the end of the game. Go ahead, Paul.

12 MR. BLANCH: Okay. I'd like to -- again, 13 I'm just going over -- I mean, I've got some editorial 14 comments, but if we go to the August 6, page 3, it 15 talks about the inspection report. And down at the 16 bottom it reads, "The NRC staff evaluated the findings 17 described in the foregoing with a green to indicate 18 low safety, despite describing a finding that it was 19 limiting the likelihood of those events." Likelihood, 20 probability has little play within the regulations.

21 Again, we don't have risk-based regulation 22 yet, and by the NRC knowing there is a violation of 23 the regulation, and not willing to bring the plant 24 into compliance with that regulation, and saying it's 25

NEAL R. GROSS COURT REPORTERS AND TRANSCRIBERS 1323 RHODE ISLAND AVE., N.W.

(202) 234-4433 WASHINGTON, D.C. 20005-3701 www.nealrgross.com 27 not significant, is not responsible regulation, as far 1

as I'm concerned.

2 And then on page 4, Paragraph 3, where 3

it's titled "Enforcement," the NRC gave four reasons 4

for not administering enforcement action. They said 5

that, "Traditional enforcement did not apply as the 6

issue did not have actual or potential safety 7

consequences." That I don't believe, unless I'm 8

wrong, my reading of the regulations, but it is not in 9

there as far as the potential consequences, but I've 10 been wrong before.

11 And then it goes on at the end of 12 Paragraph 3, "This finding did not involve enforcement 13 action because no regulatory requirement violation was 14 identified." You know, it's circular logic. And, 15 perhaps, they said it violates Appendix B, a violation 16 of General Design Criteria, but now they're saying no 17 regulatory violation. And, again, I want to make sure 18 it includes low-voltage cable, all the way down to 19 instrument, and indicating light cable. Again, it's 20 more repetitive.

21 Oh, the other thing I have. Because a 22 cable is operating in an environment that it is not 23 designed or specified for, and let's say I have a 24 cable that's in the conduit, and that conduit or 25

NEAL R. GROSS COURT REPORTERS AND TRANSCRIBERS 1323 RHODE ISLAND AVE., N.W.

(202) 234-4433 WASHINGTON, D.C. 20005-3701 www.nealrgross.com 28 manhole is full of water. And if that cable has not 1

been specified to operate in that environment, when I 2

say specified, I

mean per the procurement 3

specification, and the Quality Assurance, then it is 4

my opinion, based on the technical specification, 5

based on the definition of operability that the 6

components that are powered, or energized by that 7

cable that is operating in an environment that it was 8

not designed for cannot be considered operable until 9

proper testing is done to ascertain that that cable 10 is, in fact, operable because of its design documents.

11 And simple testing, a 10-minute test once a month, 12 once a quarter is not sufficient, and that is for the 13 reason I stated before, that one of the major aging 14 factors is due to the heating of the current caused by 15 the energization of the connected components.

16 I'm not sure where I am on time. Again, 17 I've got to note that the salt environment must be 18 considered. During the construction of Millstone III, 19 and Millstone II, I actually witnessed the pulling of 20 cables. I have seen splices in cables, in conduits, 21 and those must be identified, whether they're 22 documented or not. We don't -- I'm not sure Pilgrim 23 is aware if there are splices in cables that are 24 buried and submerged within conduits.

25

NEAL R. GROSS COURT REPORTERS AND TRANSCRIBERS 1323 RHODE ISLAND AVE., N.W.

(202) 234-4433 WASHINGTON, D.C. 20005-3701 www.nealrgross.com 29 Let's see. Again -

1 MS.

LAMPERT: That was one of the 2

questions -- this is Mary. That was one of the 3

questions that we asked to be answered, the repair 4

history. So, that should be answered, and that 5

question flows.

6 MR. BLANCH: Yes.

7 COURT REPORTER: Excuse me. This is the 8

court reporter. There's some sort of feedback coming 9

through, or sound coming from someone's phone.

10 MS. LAMPERT: It's static on the line.

11 COURT REPORTER: Okay. The static is 12 gone. Okay. You can continue.

13 MR. BLANCH: Well, I would just like --

14 again, on page 14 of the supplement. This is Paul 15 Blanch, again. Where it says under Paragraph 5.2 of 16 Mary's supplement, "Unless the installed cables have 17 been procured specifically for continuous submergence 18 or submarine operation," basically, they have not --

19 are not capable, or not have been demonstrated to be 20 operable; and, therefore, the components that they're 21 supplying power should be considered inoperable. And 22 it is, in my mind, a clear violation. We don't need 23 Regulatory Guides, we don't need Generic Letters, we 24 don't need Information Notices, we need the NRC to do 25

NEAL R. GROSS COURT REPORTERS AND TRANSCRIBERS 1323 RHODE ISLAND AVE., N.W.

(202) 234-4433 WASHINGTON, D.C. 20005-3701 www.nealrgross.com 30 its job; and that is to enforce the existing 1

regulations. We're not asking for a rule change.

2 We're asking for enforcement, and we're asking not 3

only for the identification that will explain the 4

degree of enforcement or non-compliance, but if after 5

that's identified then we're just going to see what 6

happens, as far as enforcement action. But the first 7

step is to identify the degree of non-compliance with 8

the regulations.

9 So, with that, I'll turn it over to anyone 10 else that has any questions. Thank you.

11 MS. LAMPERT: Paul, or Rebecca Chin, do 12 you have any comments?

13 MS. CHIN: I guess not at this time. I'm 14 taking notes, and perhaps later. Thank you.

15 MS. LAMPERT: Oh, Paul's on mute.

16 MR. GUNTER: This is Paul. I have no 17 comments at this time.

18 MR. BLANCH: That was Paul Gunter.

19 MS. LAMPERT: Right. Now, does the NRC 20 have any questions of the Petitioners?

21 MR. GUZMAN: Okay. I'm going to ask here, 22 does anybody in Headquarters have any questions for 23 the Petitioner? Seeing none.

24 MS. LAMPERT: Okay. With that being the 25

NEAL R. GROSS COURT REPORTERS AND TRANSCRIBERS 1323 RHODE ISLAND AVE., N.W.

(202) 234-4433 WASHINGTON, D.C. 20005-3701 www.nealrgross.com 31 case -

1 MR. GUZMAN: Mary?

2 MS. LAMPERT: For clarification, we want 3

to be sure that it is understood what is meant by 4

"inaccessible," and that cables and wiring include the 5

splices and the connectors. And for aging, we also 6

add, in particular, the salt in our environment, and 7

we also add the issue of heating, because of the 8

amount of electricity being carried for analyzing 9

degradation. And low-voltage, it's stated in the 10 petition, but we wanted to emphasize its importance.

11 Is there anything else you want to sum up, Paul?

12 MR. BLANCH: Yes. I just wanted to say 13 that EPRI is a great organization. I worked with 14 them, I worked for them. However, I want everyone to 15 realize that EPRI is fully funded by the utilities.

16 Obviously, their independence is somewhat 17 questionable. I put more credence in the Brookhaven 18 document that has a little independence, because it is 19 sponsored by both the Department of Energy, and the 20 Nuclear Regulatory Commission. And, also, in Sandia, 21 these studies are not, necessarily, funded by the 22 utilities. And as far as the priority, believability 23 of documents, you know, I put Brookhaven and Sandia on 24

top, EPRI
down, third-level, very
credible, 25

NEAL R. GROSS COURT REPORTERS AND TRANSCRIBERS 1323 RHODE ISLAND AVE., N.W.

(202) 234-4433 WASHINGTON, D.C. 20005-3701 www.nealrgross.com 32 independent organization.

And as far as NEI 1

documents, I won't even comment on the independence of 2

those documents, but their guidance is certainly 3

influenced by their motivation.

4 MR. GUZMAN: At this time, I'd like to ask 5

if the Region has any questions for the Petitioner?

6 MR. DODSON: No questions from the Region.

7 MR. GUZMAN: Okay. Does the licensee have 8

any questions?

9 MR. LYNCH: No questions.

10 MR. GUZMAN: Okay. Before I conclude the 11 meeting, members of the public may provide comments 12 regarding the petition, and ask questions about the 13 2.206 petition process. However, as stated at the 14 opening, the purpose of this meeting is not to provide 15 an opportunity for the Petitioner or public to 16 question or examine the PRB regarding the merits of 17 the petition requested. Does any member of the public 18 have any comments?

19 MS. LAMPERT: My only question would be, I 20 assume we do not have to put into writing the 21 clarifying statements or other statements made during 22 this teleconference, that they are automatically 23 included, or not?

24 MR. GUZMAN: This is Rich Guzman. That's 25

NEAL R. GROSS COURT REPORTERS AND TRANSCRIBERS 1323 RHODE ISLAND AVE., N.W.

(202) 234-4433 WASHINGTON, D.C. 20005-3701 www.nealrgross.com 33 correct. So, at the conclusion of this call, we'll 1

have a transcribed document that will be included as 2

part of your petition package. And that will -- I'll 3

provide you a copy of that, and will be publicly 4

available.

5 MS. LAMPERT: Okay. And here's just a 6

comment. I will not have any email capability for the 7

next probably 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br />, because, ironically, an 8

electric fence was being put into our property because 9

my grand-dog is, of course, now my dog, and they -- in 10 putting in the electric fence for the dog, they 11 managed to cut the wire for the cable. So, I think 12 that was an example of what can happen.

13 MR. BLANCH: Was it buried, Mary?

14 MS. LAMPERT: Yes, it was buried.

15 MR. BLANCH: Inaccessible -

16 mS. LAMPERT: Do I believe this or not?

17 MR. GUZMAN: I don't have any clarifying 18 questions to that -

19 mS. LAMPERT: Neither do I.

20 MR. GUZMAN: Okay. Ms. Lampert, thank you 21 for your taking the time to provide the NRC staff with 22 clarifying information on the petition you've 23 submitted.

24 MS. LAMPERT: Well, look, thanks for the 25

NEAL R. GROSS COURT REPORTERS AND TRANSCRIBERS 1323 RHODE ISLAND AVE., N.W.

(202) 234-4433 WASHINGTON, D.C. 20005-3701 www.nealrgross.com 34 opportunity, and I've enjoyed your emails and efforts 1

to get it all together. Thank you.

2 MR. GUZMAN: Before we close, does the 3

court reporter need any additional information for the 4

meeting transcript? Is the court reporter on line?

5 COURT REPORTER: Yes, I'm here. Just give 6

me a second.

7 MS. LAMPERT: You don't really need to put 8

the grand-dog story in.

9 (Laughter.)

10 COURT REPORTER: There was someone named 11 Alex. I didn't get his last name.

12 MS. POPOVA: Oh, Popova, P-O-P-O-V-A.

13 COURT REPORTER: That's P-O-P -

14 MR. GUZMAN: O-V-A.

15 (Off the record comments.)

16 MR. GUZMAN: Okay. Is that it?

17 COURT REPORTER: Yes, I believe so.

18 MR.

GUZMAN: Okay.

With

that, this 19 meeting is concluded, and we will be terminating the 20 phone connection. Thank you, everybody.

21 (Whereupon, the proceedings went off the 22 record at 2:51 p.m.)

23 24 25