ES-301 Administrative Topics Outline Form ES-301-1 Facility: _________Perry______________________ Date of Examination: ___06/14/1010_

Examination Level: RO  ; SRO Operating Test Number: ___2010-01 Administrative Topic Type Describe activity to be performed (see Note) Code*

D, S Perform a Valve and System Lineup on RCIC Conduct of Operations D, R Determine Requirements to Reactivate a License Conduct of Operations M, R Determine Drywell Floor and Equipment Drain Leakage Equipment Control D, R Evaluate an RWP and Survey Map Radiation Control Emergency Procedures/Plan NOTE: All items (5 total) are required for SROs. RO applicants require only 4 items unless they are retaking only the administrative topics, when all 5 are required.

  • Type Codes & Criteria: (C)ontrol room, (S)imulator, or Class(R)oom (D)irect from bank ( 3 for ROs; 4 for SROs & RO retakes)

(N)ew or (M)odified from bank ( 1)

(P)revious 2 exams ( 1; randomly selected)

ES-301 Administrative Topics Outline Form ES-301-1 Facility: _________Perry______________________ Date of Examination: ___06/14/1010_

Examination Level: RO SRO  ; Operating Test Number: ___2010-01 Administrative Topic Type Describe activity to be performed (see Note) Code*

D, S Perform a Valve and System Lineup on RCIC Conduct of Operations D, R Determine Requirements to Reactivate a License Conduct of Operations M, R Determine Drywell Floor and Equipment Drain Leakage Equipment Control D, R Evaluate an RWP and Survey Map Radiation Control D, R Classify an Event and Determine a PAR Emergency Procedures/Plan NOTE: All items (5 total) are required for SROs. RO applicants require only 4 items unless they are retaking only the administrative topics, when all 5 are required.

  • Type Codes & Criteria: (C)ontrol room, (S)imulator, or Class(R)oom (D)irect from bank ( 3 for ROs; 4 for SROs & RO retakes)

(N)ew or (M)odified from bank ( 1)

(P)revious 2 exams ( 1; randomly selected)

NUREG-1021, Revision 9 Supplement 1 FENOC Facsimile Rev.0

ES-301 Control Room/In-Plant Systems Outline- Rev 1 Form ES-301-2 Facility: _____Perry________________________ Date of Examination: ___06/14/2010_

Exam Level: RO  ; SRO-I SRO-U Operating Test No.: ____2010-01____

Control Room Systems@ (8 for RO); (7 for SRO-I); (2 or 3 for SRO-U, including 1 ESF)

System / JPM Title Type Code* Safety Function

a. Bypass and Reset Scram/ARI Signals During an ATWS C, M 1
b. Bypass HPCS and MFP Level 8 Trip for RPV Flooding C, D 2
c. Start Vacuum Pumps following a Loss of Condenser Vacuum A, S, L, M 3
d. Establish Shutdown Cooling, Head Spray then Trip Pump Due to A, S, L, M 4 Loss of Suction Pressure
e. Initiate Containment Spray A, S, N 5
f. Restore Off-Site Power D, L, C 6
g. Control Rod Bypassed in RACCS C, D 7
h. Bypass Instrument Air Isolation and Start an Air Compressor A, M, S 8 In-Plant Systems@ (3 for RO); (3 for SRO-I); (3 or 2 for SRO-U)
i. Perform Alternate Boron Injection D, E, P, R 1
j. Isolate an Instrument Air Receiver A, M, E 8
k. LPCI B Shutdown at Division 2 Remote Shutdown Panel D, E, L 7

@ All RO and SRO-I control room (and in-plant) systems must be different and serve different safety functions; all 5 SRO-U systems must serve different safety functions; in-plant systems and functions may overlap those tested in the control room.

  • Type Codes Criteria for RO / SRO-I / SRO-U (A)lternate path 4-6 / 4-6 / 2-3 (C)ontrol room (D)irect from bank 9/8/4 (E)mergency or abnormal in-plant 1/1/1 (EN)gineered safety feature - / - / 1 (control room system)

(L)ow-Power / Shutdown 1/1/1 (N)ew or (M)odified from bank including 1(A) 2/2/1 (P)revious 2 exams 3 / 3 / 2 (randomly selected)

(R)CA 1/1/1 (S)imulator NUREG-1021, Revision 9 Supplement 1 FENOC Facsimile Rev.0

ES-301 Control Room/In-Plant Systems Outline- Rev 1 FormES-301-2 Facility: _____Perry________________________ Date of Examination: ___06/14/2010_

Exam Level: RO SRO-I  ; SRO-U Operating Test No.: ____2010-01____

Control Room Systems@ (8 for RO); (7 for SRO-I); (2 or 3 for SRO-U, including 1 ESF)

System / JPM Title Type Code* Safety Function

a. Bypass and Reset Scram/ARI Signals During an ATWS C, M 1
b. Bypass HPCS and MFP Level 8 Trip for RPV Flooding C, D 2
c. Start Vacuum Pumps following a Loss of Condenser Vacuum A, S, L, M 3
d. Establish Shutdown Cooling, Head Spray then Trip Pump Due to A, S, L, M 4 Loss of Suction Pressure
e. Initiate Containment Spray A, S, N 5
f. Restore Off-Site Power D, L, C 6
g. Bypass Instrument Air Isolation and Start an Air Compressor A, M, S 8
h. n/a In-Plant Systems@ (3 for RO); (3 for SRO-I); (3 or 2 for SRO-U)
i. Perform Alternate Boron Injection D, E, P, R 1
j. Isolate an Instrument Air Receiver A, M, E 8
k. LPCI B Shutdown at Division 2 Remote Shutdown Panel D, E, L 7

@ All RO and SRO-I control room (and in-plant) systems must be different and serve different safety functions; all 5 SRO-U systems must serve different safety functions; in-plant systems and functions may overlap those tested in the control room.

  • Type Codes Criteria for RO / SRO-I / SRO-U (A)lternate path 4-6 / 4-6 / 2-3 (C)ontrol room (D)irect from bank 9/8/4 (E)mergency or abnormal in-plant 1/1/1 (EN)gineered safety feature - / - / 1 (control room system)

(L)ow-Power / Shutdown 1/1/1 (N)ew or (M)odified from bank including 1(A) 2/2/1 (P)revious 2 exams 3 / 3 / 2 (randomly selected)

(R)CA 1/1/1 (S)imulator NUREG-1021, Revision 9 Supplement 1 FENOC Facsimile Rev.0

ES-301 Control Room/In-Plant Systems Outline- Rev 1 Form ES-301-2 Facility: _____Perry________________________ Date of Examination: ___06/14/2010_

Exam Level: RO SRO-I SRO-U  ; Operating Test No.: ____2010-01____

Control Room Systems@ (8 for RO); (7 for SRO-I); (2 or 3 for SRO-U, including 1 ESF)

System / JPM Title Type Code* Safety Function

a. Establish Shutdown Cooling, Head Spray then Trip Pump Due to A, S, L, M 4 Loss of Suction Pressure
b. Initiate Containment Spray A, S, N, EN 5
c. Restore Off-Site Power D, L, C 6 d.

e f.

g.

h.

In-Plant Systems@ (3 for RO); (3 for SRO-I); (3 or 2 for SRO-U)

i. Perform Alternate Boron Injection D, E, P, R 1
j. Isolate an Instrument Air Receiver A, M, E 8 k.

@ All RO and SRO-I control room (and in-plant) systems must be different and serve different safety functions; all 5 SRO-U systems must serve different safety functions; in-plant systems and functions may overlap those tested in the control room.

  • Type Codes Criteria for RO / SRO-I / SRO-U (A)lternate path 4-6 / 4-6 / 2-3 (C)ontrol room (D)irect from bank 9/8/4 (E)mergency or abnormal in-plant 1/1/1 (EN)gineered safety feature - / - / 1 (control room system)

(L)ow-Power / Shutdown 1/1/1 (N)ew or (M)odified from bank including 1(A) 2/2/1 (P)revious 2 exams 3 / 3 / 2 (randomly selected)

(R)CA 1/1/1 (S)imulator NUREG-1021, Revision 9 Supplement 1 FENOC Facsimile Rev.0