o PBRF LABORATORY QUALITY ASSURANCE REPORT January to December 2009 111391
...-241
. 8530 32654
<Unknown>
62674 Hg--203 0. 0000 64147
<Unknown) 6 2 365 H9-203 0 _0000 55307
<Unknown >
119409 Cd-109 56080. 9961 11367
<Unknown >
SIXTH EDITION April 30, 2009 RODERICK C. CASE PBRF LABORATORY MANAGER WILLIAM STONER NASA PROJECT RADIATION SAFETY OFFICER NASA Plum Brook Reactor Facility 6100 Columbus Avenue Sandusky, Ohio 44870 O~----------------------------~
I~----------------------------~
I I
I I
I I
I I
~
~
~
~
~
o o
D o
PBRF LABORATORY QUALITY ASSURANCE REPORT January to December 2009 0. 95 129953 111391 0. 3 5 298 32654 0. 93 6 60 6 26 7 4 0. 9 3 1 2 0 64147 0. 9 3 155 3 6 2 3 6 5 0. 93 1 259 5 5 30 7 0. 95 34.706 6 119409 0. 2 8 129 1 73 6 7 I
SIXTH EDITION April 30, 2009 RODERICK C. CASE PBRFLABORATORYMANAGER WILLIAM STONER
... -241 5 8 "
. 8530
<Unknown )
8..... 2 03 0. 0000
( UnknOYD. >
89-2 03 0. 0000
<Unknown >
Cd-109 56080. 9961
<Unknown >
NASA PROJECT RADIATION SAFETY OFFICER NASA Plum Brook Reactor Facility 6100 Columbus Avenue Sandusky, Ohio 44870 O ~----------------------------~
I~------------------------------~
I I
I I
I I
I I
I I
I I
I I
I I
I TABLE OF CONTENTS SECTION PAGE 1.0 SUMMARy.......................................................................................................................... 1
2.0 INTRODUCTION
................................................................................................................ 2 3.0 DiSCUSSiON...................................................................................................................... 2 4.0 LABORATORY PROGRAM............................................................................................... 3 5.0 INTRA-LABORATORY & INTER-LABORATORY COMPARISON ANALYSIS.............4 6.0 QUALITY CONTROL CHECKS......................................................................................... 5
7.0 BACKGROUND
DETERMINATIONS................................................................................ 5 8.0 BLANK SAMPLE ANALySiS............................................................................................ 6 9.0 CROSS-CHECK PROGRAM............................................................................................. 6 10.0 LABORATORY/SAMPLE DEVIATION REPORTS...........................................................7 11.0 ATTACHMENTS.................................................................................................................7 I~----------------------------~
I~------------------------------~
I I
I I
I I
I I
I I
I I
I I
I I
I TABLE OF CONTENTS SECTION PAGE 1.0 SUMMARy.......................................................................................................................... 1
2.0 INTRODUCTION
................................................................................................................ 2 3.0 DiSCUSSiON...................................................................................................................... 2 4.0 LABORATORY PROGRAM............................................................................................... 3 5.0 INTRA-LABORATORY & INTER-LABORATORY COMPARISON ANALYSIS.............4 6.0 QUALITY CONTROL CHECKS......................................................................................... 5
7.0 BACKGROUND
DETERMINATIONS................................................................................ 5 8.0 BLANK SAMPLE ANALySiS............................................................................................ 6 9.0 CROSS-CHECK PROGRAM............................................................................................. 6 10.0 LABORATORY/SAMPLE DEVIATION REPORTS........................................................... 7 11.0 ATTACHMENTS................................................................................................................. 7 I~----------------------------~
I I
I I
I I
I I
I I
I I
I I
I I
I I
1.0
SUMMARY
1.1 Gamma Spectroscopy Systems 1.1.1 During the report period of January 1, 2009 and December 31, 2009, PBRF Laboratory personnel performed 6096 gamma spectroscopy sample analyses of 5593 samples.
PBRF performed a total of 2422 gamma spectroscopy quality assurance analyses. They include:
202 blank analyses on 202 samples 1146 Quality Control (QC) checks 534 Background checks 25 Cross-check Program sample analyses on 8 samples 26 inter-laboratory comparison (replicate) analyses on 21 samples 489 intra-laboratory comparison (replicate) analyses on 284 samples 1.1.2 Of all the QA samples that were analyzed on the PBRF Gamma Spectroscopy Systems, there were 7 discrepancies that required documentation of a Sample Deviation Report (SDR).
1.2 Liquid Scintillation Analyzer 1.2.1 PBRF laboratory personnel performed 303 tritium sample analyses during this report period.
PBRF performed a total of 1087 analyses of quality assurance (QA) samples. They include:
462 analyses on 3 reference standards 105 analyses on 105 blank samples 210 analyses on 105 background samples 210 analyses on 2 QC Check samples 78 Cross-check Program sample analyses on 6 samples 22 intra-laboratory comparison (replicate) on 22 samples 1.2.2 Of all the QA samples that were analyzed on the PBRF Liquid Scintillation Analyzer, there were no discrepancies that required documentation of a Sample Deviation Report.
1~__________________1__________________~
I I
I I
I I
I I
I I
I I
I I
I I
I I
1.0
SUMMARY
1.1 Gamma Spectroscopy Systems 1.1.1 During the report period of January 1, 2009 and December 31, 2009, PBRF Laboratory personnel performed 6096 gamma spectroscopy sample analyses of 5593 samples.
PBRF performed a total of 2422 gamma spectroscopy quality assurance analyses. They include:
202 blank analyses on 202 samples 1146 Quality Control (QC) checks 534 Background checks 25 Cross-check Program sample analyses on 8 samples 26 inter-laboratory comparison (replicate) analyses on 21 samples 489 intra-laboratory comparison (replicate) analyses on 284 samples 1.1.2 Of all the QA samples that were analyzed on the PBRF Gamma Spectroscopy Systems, there were 7 discrepancies that required documentation of a Sample Deviation Report (SDR).
1.2 Liquid Scintillation Analyzer 1.2.1 PBRF laboratory personnel performed 303 tritium sample analyses during this report period.
PBRF performed a total of 1087 analyses of quality assurance (QA) samples. They include:
462 analyses on 3 reference standards 105 analyses on 105 blank samples 210 analyses on 105 background samples 210 analyses on 2 QC Check samples 78 Cross-check Program sample analyses on 6 samples 22 intra-laboratory comparison (replicate) on 22 samples 1.2.2 Of all the QA samples that were analyzed on the PBRF Liquid Scintillation Analyzer, there were no discrepancies that required documentation of a Sample Deviation Report.
1~ __________________ 1 __________________ ~
I I
1.3 Seven Sample Deviation Reports were completed as a result of deficiencies found I
during this report period. One was associated with MAPEP Series 21 Co-60 failure.
The remainders were failures to attain agreement between intra-laboratory replicate analyses. These failures were investigated by the Laboratory Manager and corrective actions were documented. Refer to Section 10.0 of this report.
I
2.0 INTRODUCTION
2.1 This report has been prepared by the PBRF Radiological Laboratory Manager in I
accordance with PBRF procedure RP-060, PBRF Radiological Laboratory Quality Assurance/Quality Control Program. It provides a summary and interpretation of PBRF Laboratory QA Program for the period of January 1, 2009 to December 31, I
2009.
3.0 DISCUSSION I
3.1 A QA program is an essential part of any radiological monitoring program. It provides reasonable assurance that the results of radiation measurements are I
valid. To be effective, elements of QA must be evident in all phases of the monitoring program. These include, but are not limited to, sample collection, preservation and shipment, receipt of samples by the laboratory, preparation and I
analysis of samples and data review and reporting. An effective QA program will allow for the identification of deficiencies in all monitoring processes so that appropriate investigative and corrective actions can be implemented.
I 3.2 The United States Nuclear Regulatory Commission (USNRC) published Regulatory Guide 4.15, "Quality Assurance for Radiological Monitoring Programs (Normal I
Operations) - Effluent Streams and the Environment", which defines an acceptable QA program.
The guidance contained in Regulatory Guide 4.15 and NRC 10CFR50, Appendix B, "Quality Assurance Criteria for Nuclear Power Plants and I
Fuel Reprocessing Plants" has been adopted by the PBRF Facility. Procedures I
have been written and implemented to meet the objectives of these position documents.
3.3 Samples are typically analyzed only once because of workload constraints.
Therefore, laboratory personnel must be confident in the analytical results which are I
reported. One means of achieving con'fidence in the results is through the analysis of QA samples. This report provides the analytical results of various QA samples processed by the PBRF laboratory during this period.
I 3.4 Quality Control checks are performed on at least 5% of all samples analyzed on the PBRF Gamma Spectroscopy Systems and/or Liquid Scintillation Analyzer. For the I
purpose of comparing results, these samples may be analyzed in duplicate by an independent laboratory (inter-laboratory comparison) or by PBRF (intra-laboratory comparison) in their entirety or split to perform multiple analyses. The original I
analytical results are then compared with the replicate analysis results for agreement.
I 2
I~----------------------------~
I I
I 1.3 Seven Sample Deviation Reports were completed as a result of deficiencies found during this report period. One was associated with MAPEP Series 21 Co-60 failure.
The remainders were failures to attain agreement between intra-laboratory replicate analyses. These failures were investigated by the Laboratory Manager and corrective actions were documented. Refer to Section 10.0 of this report.
I
2.0 INTRODUCTION
I I
I I
I I
I I
I I
I I
I I
2.1 This report has been prepared by the PBRF Radiological Laboratory Manager in accordance with PBRF procedure RP-060, PBRF Radiological Laboratory Quality Assurance/Quality Control Program. It provides a summary and interpretation of PBRF Laboratory QA Program for the period of January 1, 2009 to December 31, 2009.
3.0 DISCUSSION 3.1 A QA program is an essential part of any radiological monitoring program. It provides reasonable assurance that the results of radiation measurements are valid. To be effective, elements of QA must be evident in all phases of the monitoring program. These include, but are not limited to, sample collection, preservation and shipment, receipt of samples by the laboratory, preparation and analysis of samples and data review and reporting. An effective QA program will allow for the identification of deficiencies in all monitoring processes so that appropriate investigative and corrective actions can be implemented.
3.2 The United States Nuclear Regulatory Commission (USNRC) published Regulatory Guide 4.15, "Quality Assurance for Radiological Monitoring Programs (Normal Operations) - Effluent Streams and the Environment", which defines an acceptable QA program.
The guidance contained in Regulatory Guide 4.15 and NRC 10CFR50, Appendix B, "Quality Assurance Criteria for Nuclear Power Plants and Fuel Reprocessing Plants" has been adopted by the PBRF Facility. Procedures have been written and implemented to meet the objectives of these position documents.
3.3 Samples are typically analyzed only once because of workload constraints.
Therefore, laboratory personnel must be confident in the analytical results which are reported. One means of achieving con'fidence in the results is through the analysis of QA samples. This report provides the analytical results of various QA samples processed by the PBRF laboratory during this period.
3.4 Quality Control checks are performed on at least 5% of all samples analyzed on the PBRF Gamma Spectroscopy Systems and/or Liquid Scintillation Analyzer. For the purpose of comparing results, these samples may be analyzed in duplicate by an independent laboratory (inter-laboratory comparison) or by PBRF (intra-laboratory comparison) in their entirety or split to perform multiple analyses. The original analytical results are then compared with the replicate analysis results for agreement.
2 I~----------------------------~
I I
I I
I I
I I
I I
I I
I I
I I
I I
3.5 The PBRF laboratory participates in the United States Department of Energy Mixed Analyte Performance Evaluation Program (MAPEP) and the Eckert & Zeigler Analytics cross check programs.
Blind spike samples are sent to the PBRF Laboratory for gamma spectroscopy and tritium analysis approximately twice a year. Results are submitted via the Internet and evaluated for agreement.
3.6 Blank samples are analytical control samples, usually distilled water or verified clean (non-radiological) sand or soil, used to demonstrate that reported analytical results are not the result of Laboratory and/or Sample Processing Facility contamination. They are used to evaluate the entire analytical procedure (sample preparation and analysis) and are prepared at the PBRF Facility for analysis in conjunction with batches or groups of regular samples.
3.7 This report is divided into the following sections:
Section 4.0 - Laboratory Program Section 5.0 - Intra-laboratory and Inter-laboratory Comparison Analysis Section 6.0 - Quality Control Checks Section 7.0 - Background Determinations Section 8.0 - Blank Sample Analysis Section 9.0 - Cross-check Program Section 10.0 - Laboratory/Sample Deviation Reports Section 11.0 - Attachments Brief discussions and summaries as well as applicable acceptance criteria are included for each section. Analytical results, which did not meet the specified acceptance criteria, are noted and discussed.
4.0 LABORATORY PROGRAM 4.1 The PBRF Radiological Laboratory is designed to support the analytical requirements of decommissioning work activities, environmental program, and Final Status Survey. The laboratory consists of three high resolution gamma spectroscopy units, one liquid scintillation counter, and three gas flow proportional alphalbeta counters. The laboratory is operated by qualified personnel with documented training on all of the laboratory equipment. Sample processing is performed in accordance with site procedures and chain of custody is maintained for all samples. There were no significant laboratory program changes during this period.
3 I~----------------------------~
I I
I I
I I
I I
I I
I I
I I
I I
I I
3.5 The PBRF laboratory participates in the United States Department of Energy Mixed Analyte Performance Evaluation Program (MAPEP) and the Eckert & Zeigler Analytics cross check programs.
Blind spike samples are sent to the PBRF Laboratory for gamma spectroscopy and tritium analysis approximately twice a year. Results are submitted via the Internet and evaluated for agreement.
3.6 Blank samples are analytical control samples, usually distilled water or verified clean (non-radiological) sand or soil, used to demonstrate that reported analytical results are not the result of Laboratory and/or Sample Processing Facility contamination. They are used to evaluate the entire analytical procedure (sample preparation and analysis) and are prepared at the PBRF Facility for analysis in conjunction with batches or groups of regular samples.
3.7 This report is divided into the following sections:
Section 4.0 - Laboratory Program Section 5.0 - Intra-laboratory and Inter-laboratory Comparison Analysis Section 6.0 - Quality Control Checks Section 7.0 - Background Determinations Section 8.0 - Blank Sample Analysis Section 9.0 - Cross-check Program Section 10.0 - Laboratory/Sample Deviation Reports Section 11.0 - Attachments Brief discussions and summaries as well as applicable acceptance criteria are included for each section. Analytical results, which did not meet the specified acceptance criteria, are noted and discussed.
4.0 LABORATORY PROGRAM 4.1 The PBRF Radiological Laboratory is designed to support the analytical requirements of decommissioning work activities, environmental program, and Final Status Survey. The laboratory consists of three high resolution gamma spectroscopy units, one liquid scintillation counter, and three gas flow proportional alphalbeta counters. The laboratory is operated by qualified personnel with documented training on all of the laboratory equipment. Sample processing is performed in accordance with site procedures and chain of custody is maintained for all samples. There were no significant laboratory program changes during this period.
3 I~----------------------------~
I I
I I
I I
I I
I I
I I
I I
I I
I I
5.0 INTRA-LABORATORY & INTER-LABORATORY COMPARISON ANALYSIS 5.1 For this report period, 489 gamma spectroscopy comparison analyses were performed on 284 intra-laboratory samples and 26 gamma spectroscopy comparison analyses were performed on 21 inter-laboratory samples.
This equates to approximately 8% of the total gamma spectroscopy sample analysis performed during the report period. Six intra-laboratory comparison results were not in agreement and a Sample Deviation Report was completed for each. All of the remaining comparison analyses performed in this period were in agreement.
5.2 For this report period, 22 intra-laboratory tritium comparative analyses were performed on 22 samples. This is approximately 7.3% of the total tritium sample analysis performed during the report period. All of the comparative analyses performed in this period were in agreement.
5.3 To determine agreement, the original result is divided by its associated one sigma uncertainty to obtain the resolution and the original result is then divided by the corresponding replicate result to obtain the ratio.
5.4 The measurement is in agreement if the value of the ratio falls within the limits shown in Table 3 for the corresponding resolution. The criteria are similar to those listed in USNRC Inspection Procedure 84750, "Radioactive Waste Treatment, and Effluent and Environmental Monitoring" with minor adjustments to account for activity concentrations with large uncertainties.
5.5 If both sample results are less than Minimum Detectable Activity (MDA), they are in agreement. When comparing a positive result to a <MDA result, the MDA value is assumed to be positive activity and used to calculate the ratio.
5.6 Those sample analyses that do not agree are annotated by a "NO" answer in the "Agreement" column. The corresponding Sample Deviation Report (SDR) number can be located in the "SDR Number" column.
TABLE 1: SAMPLE RESOLUTION AND RATIO AGREEMENT CRITERIA
<4 0.4-2.5 4-7 0.5 - 2.0 8-15 0.6 -1.66 16 - 50 0.75 -1.33 51 - 200 0.8 -1.25
>200 0.85 -1.18 5.7 Intra-laboratory results are shown in Attachment 1. Inter-laboratory results are shown in Attachment 2.
4 I~------------------------------
I I
I I
I I
I I
I I
I I
I I
I I
I I
5.0 INTRA-LABORATORY & INTER-LABORATORY COMPARISON ANALYSIS 5.1 For this report period, 489 gamma spectroscopy comparison analyses were performed on 284 intra-laboratory samples and 26 gamma spectroscopy comparison analyses were performed on 21 inter-laboratory samples.
This equates to approximately 8% of the total gamma spectroscopy sample analysis performed during the report period. Six intra-laboratory comparison results were not in agreement and a Sample Deviation Report was completed for each. All of the remaining comparison analyses performed in this period were in agreement.
5.2 For this report period, 22 intra-laboratory tritium comparative analyses were performed on 22 samples. This is approximately 7.3% of the total tritium sample analysis performed during the report period. All of the comparative analyses performed in this period were in agreement.
5.3 To determine agreement, the original result is divided by its associated one sigma uncertainty to obtain the resolution and the original result is then divided by the corresponding replicate result to obtain the ratio.
5.4 The measurement is in agreement if the value of the ratio falls within the limits shown in Table 3 for the corresponding resolution. The criteria are similar to those listed in USNRC Inspection Procedure 84750, "Radioactive Waste Treatment, and Effluent and Environmental Monitoring" with minor adjustments to account for activity concentrations with large uncertainties.
5.5 If both sample results are less than Minimum Detectable Activity (MDA), they are in agreement. When comparing a positive result to a <MDA result, the MDA value is assumed to be positive activity and used to calculate the ratio.
5.6 Those sample analyses that do not agree are annotated by a "NO" answer in the "Agreement" column. The corresponding Sample Deviation Report (SDR) number can be located in the "SDR Number" column.
TABLE 1: SAMPLE RESOLUTION AND RATIO AGREEMENT CRITERIA
<4 0.4-2.5 4-7 0.5 - 2.0 8-15 0.6 -1.66 16 - 50 0.75 -1.33 51 - 200 0.8 -1.25
>200 0.85 -1.18 5.7 Intra-laboratory results are shown in Attachment 1. Inter-laboratory results are shown in Attachment 2.
4 I~------------------------------
I I
I I
I I
I I
I I
I I
I I
I I
I I
6.0 QUALITY CONTROL CHECKS 6.1 A Quality Control Check is performed on the PBRF Gamma Spectroscopy Systems daily before analyzing samples and immediately after changes in electronic components that may affect system operability.
The results are compared to parameters specified in RP-021, Rev. 1, Operation and Calibration of the ORTEC Gamma Spectroscopy System. If results are not within the prescribed ranges additional Quality Control Checks are performed to determine if cause is due to statistical variation or if system adjustments are necessary. Additional checks are performed and verified prior to placing the system in operation. A total of 1146 Quality Control Checks were performed during this period. No Quality Control Check defiCiency resulted in removing a detector from operation.
6.2 A system normalization and calibration using flame-sealed unquenched Carbon 14, Tritium, and background reference standards traceable to the National Institute of Standards (NIST) is performed on the PBRF Liquid Scintillation Analyzer daily before analyzing samples and immediately after changes in electronic components that may affect system operability.
The results are compared to parameters specified in RP-020, Rev. 0, Packard TriCarb 2900 TR Liquid Scintillation Analyzer. Results that are not within the prescribed ranges are investigated prior to placing the system in operation. A total of 154 system normalization and calibrations were performed. No deficiencies were noted.
6.3 Two tritium QC Check samples are analyzed on the Liquid Scintillation Analyzer with each batch of samples. The QC check samples are prepared from a NIST traceable tritium source solution and scintillation cocktail. One QC Check is placed before the sample set and one is placed after the sample set. Tritium QC check samples were analyzed in 105 sample batches during this report period. The results are compared to parameters specified in RP-020, Rev. 0, Packard TriCarb 2900 TR Liquid Scintillation Analyzer. Results that are not within the prescribed ranges are flagged on the sample analysis report. No deficiencies were noted.
7.0 BACKGROUND
DETERMINATIONS 7.1 A background check is performed on the Gamma Spectroscopy Systems at least daily as required by procedure PBRF-RP-021, Rev. 2, Operation and Calibration of the ORTEC Gamma Spectroscopy System. Background determinations are used to ensure that the counting environment is free of contamination. Background results are plotted daily to observe trends and unusual results. A total of 534 background checks were performed on the PBRF Gamma Spectroscopy Systems during this report period. All background checks were performed satisfactorily. No deficiencies were noted.
7.2 A background reference sample is analyzed daily prior to sample counting to calculate the figure of merit (FOM) quench indicating parameter (QIP) of E2/B. This value is used to determine counting efficiency.
7.3 Two background samples are analyzed on the Liquid Scintillation Analyzer with each batch of samples. The background samples are prepared with de-ionized 5
I--------------------------------~
I I
6.0 QUALITY CONTROL CHECKS I
I I
I I
I I
I I
I I
I I
I I
I 6.1 A Quality Control Check is performed on the PBRF Gamma Spectroscopy Systems daily before analyzing samples and immediately after changes in electronic components that may affect system operability.
The results are compared to parameters specified in RP-021, Rev. 1, Operation and Calibration of the ORTEC Gamma Spectroscopy System. If results are not within the prescribed ranges additional Quality Control Checks are performed to determine if cause is due to statistical variation or if system adjustments are necessary. Additional checks are performed and verified prior to placing the system in operation. A total of 1146 Quality Control Checks were performed during this period. No Quality Control Check defiCiency resulted in removing a detector from operation.
6.2 A system normalization and calibration using flame-sealed unquenched Carbon-14, Tritium, and background reference standards traceable to the National Institute of Standards (NIST) is performed on the PBRF Liquid Scintillation Analyzer daily before analyzing samples and immediately after changes in electronic components that may affect system operability.
The results are compared to parameters specified in RP-020, Rev. 0, Packard TriCarb 2900 TR Liquid Scintillation Analyzer. Results that are not within the prescribed ranges are investigated prior to placing the system in operation. A total of 154 system normalization and calibrations were performed. No deficiencies were noted.
6.3 Two tritium QC Check samples are analyzed on the Liquid Scintillation Analyzer with each batch of samples. The QC check samples are prepared from a NIST traceable tritium source solution and scintillation cocktail. One QC Check is placed before the sample set and one is placed after the sample set. Tritium QC check samples were analyzed in 105 sample batches during this report period. The results are compared to parameters specified in RP-020, Rev. 0, Packard TriCarb 2900 TR Liquid Scintillation Analyzer. Results that are not within the prescribed ranges are flagged on the sample analysis report. No deficiencies were noted.
7.0 BACKGROUND
DETERMINATIONS 7.1 A background check is performed on the Gamma Spectroscopy Systems at least daily as required by procedure PBRF-RP-021, Rev. 2, Operation and Calibration of the ORTEC Gamma Spectroscopy System. Background determinations are used to ensure that the counting environment is free of contamination. Background results are plotted daily to observe trends and unusual results. A total of 534 background checks were performed on the PBRF Gamma Spectroscopy Systems during this report period. All background checks were performed satisfactorily. No deficiencies were noted.
7.2 A background reference sample is analyzed daily prior to sample counting to calculate the figure of merit (FOM) quench indicating parameter (QIP) of E2/B. This value is used to determine counting efficiency.
7.3 Two background samples are analyzed on the Liquid Scintillation Analyzer with each batch of samples. The background samples are prepared with de-ionized 5
I--------------------------------~
I
=
I I
I I
I I
I I
I I
I I
I I
water and scintillation cocktail. One background sample is placed before the sample set and one is placed after the sample set. Results are used to subtract a background count from the sample count and calculate an MDA. Background samples were analyzed in 105 sample batches during this report period. No deficiencies were noted.
8.0 BLANK SAMPLE ANALYSIS 8.1 Sample Processing Facility and Laboratory Technicians prepare blank samples during the processing of regular samples in accordance with RP-060 and RP-020.
The analysis of blank samples ensures that measurement error is not the result of contamination of sampling equipment or processing techniques. The acceptance criteria for blank sample results are no detectable PBRF related activity above the target Minimum Detectable Activity (MDA).
8.1.1 A total of 202 Gamma Spectroscopy Analyses were performed on 202 blank samples during this report period. No PBRF related gamma activity was detected in any blank sample above the analysis MDA.
8.1.2 A total of 105 tritium analyses were performed on 105 blank samples during this report period. No tritium activity was observed in any blank sample above the analysis MDA.
9.0 CROSS-CHECK PROGRAM 9.1 PBRF participates in the United States Department of Energy (DOE) Mixed Analyte Performance Evaluation Program (MAPEP). Various sample matrices are prepared for DOE by the Radiological and Environmental Sciences Laboratory (RESL) and sent to program participants for analysis. Participating laboratories report and receive results via the MAPEP website. PBRF receives a water, soil, and air filter sample. MAPEP Series 20 was issued in January 2009. All reported results were within the acceptance range (+/- 30%) for each sample matrix. Series 21 was issued in July 2009 and resulted in a Co-60 failure on the air filter (RdF) sample. Co-60 was reported outside the acceptance range (> 30%) of the reference value for the RdF sample. A replicate analysis performed on these results was in agreement with the reference values. The reported results for this geometry have consistently been biased high compared to the reference value.
This has been a recurring problem with this geometry and was reported to ORTEC service personnel. Investigation and additional testing is in progress to resolve this issue. The remaining results were within the acceptance range for each sample matrix. MAPEP Series 20 and 21 results are shown in Attachment 4.
9.2 Tritium cross-check samples obtained from Eckert & Ziegler Analytics were analyzed in March and September. Each sample was analyzed multiple times to reduce the counting uncertainty. The average of these analysis and uncertainties are then reported to Eckert & Ziegler Analytics. The cross-check sample results were within the acceptable range of the standard for both series. Cross-check results are shown in Attachment 4.
6 I------------------------------~
=
water and scintillation cocktail. One background sample is placed before the sample set and one is placed after the sample set. Results are used to subtract a background count from the sample count and calculate an MDA. Background samples were analyzed in 105 sample batches during this report period. No deficiencies were noted.
I 8.0 BLANK SAMPLE ANALYSIS I
I I
I I
I I
I I
I I
I I
I 8.1 Sample Processing Facility and Laboratory Technicians prepare blank samples during the processing of regular samples in accordance with RP-060 and RP-020.
The analysis of blank samples ensures that measurement error is not the result of contamination of sampling equipment or processing techniques. The acceptance criteria for blank sample results are no detectable PBRF related activity above the target Minimum Detectable Activity (MDA).
8.1.1 A total of 202 Gamma Spectroscopy Analyses were performed on 202 blank samples during this report period. No PBRF related gamma activity was detected in any blank sample above the analysis MDA.
8.1.2 A total of 105 tritium analyses were performed on 105 blank samples during this report period. No tritium activity was observed in any blank sample above the analysis MDA.
9.0 CROSS-CHECK PROGRAM 9.1 PBRF participates in the United States Department of Energy (DOE) Mixed Analyte Performance Evaluation Program (MAPEP). Various sample matrices are prepared for DOE by the Radiological and Environmental Sciences Laboratory (RESL) and sent to program participants for analysis. Participating laboratories report and receive results via the MAPEP website. PBRF receives a water, soil, and air filter sample. MAPEP Series 20 was issued in January 2009. All reported results were within the acceptance range (+/- 30%) for each sample matrix. Series 21 was issued in July 2009 and resulted in a Co-60 failure on the air filter (RdF) sample. Co-60 was reported outside the acceptance range (> 30%) of the reference value for the RdF sample. A replicate analysis performed on these results was in agreement with the reference values. The reported results for this geometry have consistently been biased high compared to the reference value.
This has been a recurring problem with this geometry and was reported to ORTEC service personnel. Investigation and additional testing is in progress to resolve this issue. The remaining results were within the acceptance range for each sample matrix. MAPEP Series 20 and 21 results are shown in Attachment 4.
9.2 Tritium cross-check samples obtained from Eckert & Ziegler Analytics were analyzed in March and September. Each sample was analyzed multiple times to reduce the counting uncertainty. The average of these analysis and uncertainties are then reported to Eckert & Ziegler Analytics. The cross-check sample results were within the acceptable range of the standard for both series. Cross-check results are shown in Attachment 4.
6 I------------------------------~
I I
10.0 LASORA TORY/SAMPLE DEVIATION REPORTS I
10.1 A Laboratory/Sample Deviation Report (SDR) provides a method to document sampling or sample analysis conditions that are adverse to quality.
The I
identification of the condition adverse to quality, the cause of the condition, and the corrective action taken are documented and reported to the appropriate levels of management.
I 10.2 Each SDR is completed in accordance with procedure RP-060, PBRF Radiological Laboratory Quality Assurance/Quality Control Program.
I 10.3 A total of 7 SDRs were completed during this report period. Each incident was investigated by the Laboratory Manager and corrective actions were addressed. All I
SDRs were closed except SDR-09-007, which is under investigation. A copy of each SDR is provided in Attachment 3. The SDRs consisted of the following:
I SDR-09-001 - Replicate not in agreement SDR-09-002 - Replicate not in agreement I
SDR-09-003 - Replicate not in agreement SDR-09-004 - Replicate not in agreement I
SDR-09-005 - Replicate not in agreement SDR-09-006 - Replicate not in agreement I
SDR-09-007 - MAPEP Air Filter exceeds reference value for Co-60 11.0 ATTACHMENTS I - Intra-Laboratory Comparison Results I -Inter-Laboratory Comparison Results - Sample Deviation Reports I - Cross-Check Reports I
I I
I 7
I~----------------------------~
I I
I I
I I
I I
I I
I I
I I
I I
I I
10.0 LASORA TORY/SAMPLE DEVIATION REPORTS 10.1 A Laboratory/Sample Deviation Report (SDR) provides a method to document sampling or sample analysis conditions that are adverse to quality.
The identification of the condition adverse to quality, the cause of the condition, and the corrective action taken are documented and reported to the appropriate levels of management.
10.2 Each SDR is completed in accordance with procedure RP-060, PBRF Radiological Laboratory Quality Assurance/Quality Control Program.
10.3 A total of 7 SDRs were completed during this report period. Each incident was investigated by the Laboratory Manager and corrective actions were addressed. All SDRs were closed except SDR-09-007, which is under investigation. A copy of each SDR is provided in Attachment 3. The SDRs consisted of the following:
SDR-09-001 - Replicate not in agreement SDR-09-002 - Replicate not in agreement SDR-09-003 - Replicate not in agreement SDR-09-004 - Replicate not in agreement SDR-09-005 - Replicate not in agreement SDR-09-006 - Replicate not in agreement SDR-09-007 - MAPEP Air Filter exceeds reference value for Co-60 11.0 ATTACHMENTS - Intra-Laboratory Comparison Results -Inter-Laboratory Comparison Results - Sample Deviation Reports - Cross-Check Reports 7
I~----------------------------~
I I
I I
I I
I I
I I
I I
I I
I I
I I
I ATTACHMENT 1 Intra-Laboratory Comparison Results 8
I I
I I
I I
ATTACHMENT 1 I
Intra-Laboratory Comparison Results I
I I
I I
I I
I I
I I
I 8
INTRA-LABORATORY COMPARISON (REPLICATE) RESULTS
~--~
c:
SDR c:
Gamma Log Sample ID Replicate Original 0
Q)
Number Acquisition Sample Original Replicate
',p E
Number Number Analysis Nudide Units 2 Sigma
~
Ratio SDR-e Q)
(Original)
(Replicate)
Date Type Performed By Result Result Uncertainty tJ)
~
09 Q)
Jl IX:
'---~ ~--
PB09-oo020 PB09-00021 1m2009 Puck PBRF K-40 pCilg 1.26E+01 8.50E+00 3.00E+00 8.0 0.67 YES N/A
--~
PB09-00040 PB08-00041 111312009 Water PBRF K-40 pCilg 7.70E-01 7.ooE-01 2.ooE-01 8.0 0.91 YES N/A PB09-00040 PB08-00041 1/1312009 Water PBRF H3 pCi/ml
<MDA
<MDA NlA NlA NlA YES N/A I--
~-~
PB09-oo080 PB08-00081 1/1412009 Puck PBRF K-40 pCilg 1.17E+01 6.00E+00 5.96E+00 3.9 0.51 YES N/A
~-~
PB09-oo080 PB08-00081 1/1412009 Puck PBRF Cs-137 pCilg 3.10E+00 1.90E+00 1.87E+00 3.3 0.61 YES N/A PB09-oo1oo PB08-OO101 1/1512009 Puck PBRF K-40 pCilg
<MDA
<MDA N/A N/A N/A YES N/A
~-~
PB09-oo120 PB08-oo121 1/1912009 Puck PBRF K-40 pCilg 8.40E+00 7.50E+00 2.10E+00 8.0 0.89 YES NlA PB09-oo140 PB08-OO141 1/1912008 Puck PBRF K-40 pCi/g 9.80E+00 1.77E+01 2.33E+00 8.0 1.81 NO 001
~-
PB09-00140 PB08-oo141 1/1912008 Puck PBRF Cs-137 pCi/g 9.22E+01 1.57E+02 3.50E+00 53.0 1.70 NO 001
--~
PB09-00140 PB08-00141 112012009 Puck PBRF K-40 pCilg 9.80E+00 1.00E+01 2.33E+00 8.0 1.08 YES N/A
--~
--~
PB09-oo140 PB08-oo141 1/2012009 Puck PBRF Cs-137 pCilg 9.22E+01 8.51E+01 3.50E+00 53.0 0.92 YES N/A -
PB09-00160 PB09-00161 21212009 Water PBRF K-40 pCilg 1.10E+00 1.30E+00 2.50E-01 9.0 1.18 YES N/A PB09-00160 PB09-00161 21212009 Water PBRF H3 pCilml 7.20E+00 7.20E+00 1.42E+OO 10.0 1.00 YES N/A
--~-
--~
PB09-oo180 PB09-oo181 215/2009 Soil PBRF K-40 pCilg 1.46E+01 1.46E+01 2.40E+00 12.0 1.00 YES N/A PB09-00180 PB09-oo181 21512009 Soil PBRF CO-60 pCilg 1.80E-01 1.30E-01 6.00E-02 6.0 0.72 YES N/A
~~~
~
PB09-00180 PB09-00181 2/512009 Soil PBRF Cs-137 pCi/g 1.24E+00 1.30E+00 1.90E-01 13.0 1.05 YES N/A
~-~
PB09-oo2oo PB09-00201 21912009 Puck PBRF K-40 pCilg 8.10E+00 9.40E+00 1.90E+00 9.0 1.16 YES NlA I---~
~--
PB09-oo220 PB09-oo221 211012009 Puck PBRF K-40 pCilg 8.ooE+00 7.60E+00 1.70E+00 9.0 0.95 YES NlA PB09-00240 PB09-00241 3/912009 Water PBRF K-40 pCilg 8.ooE-01 1.10E+00 2.10E-01 8.0 1.38 YES NlA PB09-oo240 PB09-00241 31912009 Water PBRF Cs-137 pCilg 2.80E-02 1.4DE-02 1.44E-02 3.9 0.50 YES NlA 9
INTRA-LABORATORY COMPARISON (REPLICATE) RESULTS c:
SDR c:
Gamma Log Sample ID Replicate Original 0
Q)
Number Acquisition Sample Original Replicate
',p E
Number Number Analysis Nudide Units 2 Sigma
~
Ratio SDR-e Q)
(Original)
(Replicate)
Date Type Performed By Result Result Uncertainty tJ)
~
09-Q)
Jl IX:
r-PB09-oo020 PB09-00021 1m2009 Puck PBRF K-40 pCilg 1.26E+01 8.50E+00 3.00E+00 8.0 I 0.67 YES N/A PB09-00040 PB08-00041 111312009 Water PBRF K-40 pCilg 7.70E-01 7.ooE-01 2.ooE-01 8.0 0.91 YES I N/A PB09-00040 PB08-00041 1/1312009 Water PBRF H3 pCi/ml
<MDA
<MDA NlA NlA NlA YES N/A
~-
PB09-oo080 PB08-00081 1/1412009 I Puck PBRF K-40 pCilg 1.17E+01 6.00E+00 5.96E+00 3.9 0.51 YES N/A PB09-oo080 PB08-00081 1/1412009 Puck PBRF Cs-137 pCilg 3.10E+00 1.90E+00 1.87E+00 3.3 0.61 YES N/A PB09-oo1oo PB08-OO101 1/1512009 Puck PBRF K-40 pCilg
<MDA
<MDA N/A N/A N/A YES N/A PB09-oo120 PB08-oo121 1/1912009 Puck PBRF K-40 pCilg 8.40E+00 7.50E+00 2.10E+00 8.0 0.89 YES NlA f----
PB09-oo140 PB08-OO141 1/1912008 Puck PBRF K-40 pCi/g 9.80E+00 1.77E+01 2.33E+00 8.0 1.81 NO 001 PB09-00140 PB08-oo141 1/1912008 Puck PBRF Cs-137 pCi/g 9.22E+01 1.57E+02 3.50E+00 53.0 1.70 NO 001 PB09-00140 PB08-00141 112012009 Puck PBRF K-40 pCilg 9.80E+00 1.00E+01 2.33E+00 8.0 1.08 YES N/A PB09-oo140 PB08-oo141 1/2012009 Puck PBRF Cs-137 pCilg 9.22E+01 8.51E+01 3.50E+00 53.0 0.92 YES N/A -
PB09-00160 PB09-00161 21212009 Water PBRF K-40 pCilg 1.10E+00 1.30E+00 2.50E-01 9.0 1.18 YES N/A PB09-00160 PB09-00161 21212009 Water PBRF H3 pCilml 7.20E+00 7.20E+00 1.42E+OO 10.0 1.00 YES N/A PB09-oo180 PB09-oo181 215/2009 Soil PBRF K-40 pCilg 1.46E+01 1.46E+01 2.40E+00 12.0 1.00 YES N/A PB09-00180 PB09-oo181 21512009 Soil PBRF CO-60 pCilg 1.80E-01 1.30E-01 6.00E-02 6.0 0.72 YES N/A 1-----
PB09-00180 PB09-00181 2/512009 Soil PBRF Cs-137 pCi/g 1.24E+00 1.30E+00 1.90E-01 13.0 1.05 YES N/A PB09-oo2oo PB09-00201 21912009 Puck PBRF K-40 pCilg 8.10E+00 9.40E+00 1.90E+00 9.0 1.16 YES NlA PB09-oo220 PB09-oo221 211012009 Puck PBRF K-40 pCilg 8.ooE+00 7.60E+00 1.70E+00 9.0 0.95 YES NlA PB09-00240 PB09-00241 3/912009 Water PBRF K-40 pCilg 8.ooE-01 1,10E+00 2.10E-01 8.0 1,38 YES NlA PB09-oo240 PB09-00241 3/912009 Water PBRF Cs-137 pCilg 2.80E-02 1.4DE-02 1.44E-02 3.9 0.50 YES NlA 9
INTRA-LABORATORY COMPARISON (REPLICATE) RESULTS c:
E SDR Gamma Log Sample 10 Replicate Original
~
<J)
Number Acquisition Sample Original Repliec;ne E
Number Number Analysis Nuclide Units 2 Sigma l5 Ratio
~
SDR (Original)
(Replicate)
Date Type Performed By Result Result Uncertainty U) 09
<J)
Cl 0::
~~~
--~~
PB09-oo240 PB09-oo241 31912009 Water PBRF H3 pCilml 1.40E+00 1.4DE+00 1.00E+00 2.8 1.00 YES N/A PB09-oo260 PB09-oo261 3/1212009 Soil PBRF K-40 pCilg 1.02E+01 8.85E+00 1.70E+OO 12.0 0.86 YES N/A
~-~ -
PB09-00280 PB09-oo281 311612009 Soil PBRF K-40 pCilg 4.27E+00 3.92E+00 1.ooE+00 9.0 0.92 YES N/A I
PB09-oo280 PB09-00281 3/1612009 Soil PBRF Cs-137 pCi/g 8.70E-01 8.20E-01 1.26E+00 1.4 0.94 YES N/A PBOO-oo300 PBOO-00301 3/1812009 Soil PBRF K-40 pCilg 1.20E+01 1.46E+01 1.80E+00 13.0 1.22 YES N/A PB08-oo300 PB08-oo301 311812009 Soil PBRF Cs-137 pCilg 2.90E-01 2.70E-01 7.90E-02 7.0 0.93 YES N/A PBOO-OO320 PB08-OO321 312312009 Soil PBRF K-40 pCi/g 1.80E+01 2.05E+01 2.60E+00 14.0 1.14 YES N/A PB08-00320 PBOO-00321 312312009 Soil PBRF Cs-137 pCi/g 3.ooE-01 1.50E-01 1.ooE-01 6.0 0.50 YES N/A PB08-OO340 PB08-oo341 312612009 Water PBRF K-40 pCi/g 4.20E-01 7.80E-01 1.20E-01 7.0 1.86 YES N/A PB08-00340 PBOO-OO341 312612009 Water PBRF Cs-137 pCilg
<MDA
<MDA N/A N/A N/A YES N/A
--~
PB08-00340 PBOO-00341 312612009 Water PBRF H3 pCilml
<MDA
<MDA N/A N/A N/A YES N/A
~-~
PB08-OO360 PB08-oo361 312612009 Soil PBRF K-40 pCilg 4.30E+00 3.00E+OO 1.10E+00 8.0 0.70 YES N/A PB08-00360 PBOO-OO361 312612009 Soil PBRF Cs-137 pCi/g 6.10E+00 6.10E+00 3.80E-01 32.0 1.00 YES N/A
~-
PB09-00380 PB09-00381 41212009 Soil PBRF K-40 pCi/g 1.52E+01 1.29E+01
- 2. 15E+00 14.0 0.85 YES N/A PB09-00380 PB09-oo381 41212009 Soil PBRF Cs-137 pCi/g 1.80E-01 1.70E-01 7.ooE-02 5.0 0.94 YES N/A PB09-00400 PB09-00401 4/1512009 Puck PBRF K-40 pCi/g 9.90E+00 9.70E+00 2.60E+00 8.0 0.98 YES N/A
~---~-
PB09-oo400 PB09-00401 4/1512009 Puck PBRF Cs-137 pCilg 2.50E+00 2.50E+00 3.30E-01 15.0 1.00 YES N/A PB09-00420 PB09-00421 41912009 Soil PBRF K-40 pCilg 1.65E+01 1.54E+01 2.42E+00 14.0 0.93 YES N/A PB09-00420 PB09-00421 41912009 Soil PBRF Cs-137 pCilg 1.18E-01 6.00E-02 6.50E-02 3.6 0.51 YES N/A
-~ -
~-
PB09-00440 PB09-00441 4/1412009 Soil PBRF K-40 pCi/g 1.50E+01 1.60E+01 2.30E+OO 13.0 1.07 YES N/A 10 INTRA-LABORATORY COMPARISON (REPLICATE) RESULTS c:
E SDR Gamma Log Sample 10 Replicate Original
~
<J)
Number Acquisition Sample Original Repliec;ne E
Number Number Analysis Nuclide Units 2 Sigma l5 Ratio
~
SDR-(Original)
(Replicate)
Date Type Performed By Result Result Uncertainty U) 09-
<J)
Cl 0::
I----~
--~~
PB09-oo240 PB09-oo241 31912009 Water PBRF H3 pCilml 1.40E+00 1.4DE+00 1.00E+00 2.8 1.00 YES N/A PB09-oo260 PB09-oo261 3/1212009 Soil PBRF K-40 pCilg 1.02E+01 8.85E+00 1.70E+OO 12.0 0.86 YES N/A
~-~
PB09-00280 PB09-oo281 311612009 Soil PBRF K-40 pCilg 4.27E+00 3.92E+00 1.ooE+00 9.0 0.92 YES N/A
~-
PB09-oo280 PB09-00281 3/1612009 Soil PBRF Cs-137 pCi/g 8.70E-01 8.20E-01 1.26E+00 1.4 0.94 YES N/A PBOO-oo300 PBOO-00301 3/1812009 Soil PBRF K-40 pCilg 1.20E+01 1.46E+01 1.80E+00 13.0 1.22 YES N/A
--~
PB08-oo300 PB08-oo301 311812009 Soil PBRF Cs-137 pCilg 2.90E-01 2.70E-01 7.90E-02 7.0 0.93 YES N/A PBOO-OO320 PB08-OO321 312312009 Soil PBRF K-40 pCi/g 1.80E+01 2.05E+01 2.60E+00 14.0 1.14 YES N/A PB08-00320 PBOO-00321 312312009 Soil PBRF Cs-137 pCi/g 3.ooE-01 1.50E-01 1.ooE-01 6.0 0.50 YES N/A PB08-OO340 PB08-oo341 312612009 Water PBRF K-40 pCi/g 4.20E-01 7.80E-01 1.20E-01 7.0 1.86 YES N/A PB08-00340 PBOO-OO341 312612009 Water PBRF Cs-137 pCilg
<MDA
<MDA N/A N/A N/A YES N/A
--~
PB08-00340 PBOO-00341 312612009 Water PBRF H3 pCilml
<MDA
<MDA N/A N/A N/A YES N/A
~-~
PB08-OO360 PB08-oo361 312612009 Soil PBRF K-40 pCilg 4.30E+00 3.00E+OO 1.10E+00 8.0 0.70 YES N/A
~-
PB08-00360 PBOO-OO361 312612009 Soil PBRF Cs-137 pCi/g 6.10E+00 6.10E+00 3.80E-01 32.0 1.00 YES N/A
~-
PB09-00380 PB09-00381 41212009 Soil PBRF K-40 pCi/g 1.52E+01 1.29E+01
- 2. 15E+00 14.0 0.85 YES N/A PB09-00380 PB09-oo381 41212009 Soil PBRF Cs-137 pCi/g 1.80E-01 1.70E-01 7.ooE-02 5.0 0.94 YES N/A I PB09-00400 PB09-00401 4/1512009 Puck PBRF K-40 pCi/g 9.90E+00 9.70E+00 2.60E+00 8.0 0.98 YES N/A
~---~-
PB09-oo400 PB09-00401 4/1512009 Puck PBRF Cs-137 pCilg 2.50E+00 2.50E+00 3.30E-01 15.0 1.00 YES N/A PB09-00420 PB09-00421 41912009 Soil PBRF K-40 pCilg 1.65E+01 1.54E+01 2.42E+00 14.0 0.93 YES N/A PB09-00420 PB09-00421 41912009 Soil PBRF Cs-137 pCilg 1.18E-01 6.00E-02 6.50E-02 3.6 0.51 YES N/A
-~ --
~-
PB09-00440 PB09-00441 4/1412009 Soil PBRF K-40 I
pCi/g 1.50E+01 1.60E+01 2.30E+OO 13.0 1.07 YES N/A 10
I INTRA-LABORATORY COMPARISON (REPLICATE) RESULTS Replicate c:
SDR c:
Gamma Log Sample ID Original
.Q Q)
Number Number Number Acquisition Sample Analysis Nuclide Units Original Replicate 2 Sigma "5
Ratio E
SDR-Date Type Performed Result Result Q)
(Original)
(Replicate)
Uncertainty
~
09 By Q)
~
0:::
PB09-OO440 PB09-00441 411412009 Soil PBRF K-40 pCVg 1.80E-01 3.00E-01 7.40E-02 S.O 1.67 YES N/A PB09-00460 PB09-0050S 411612009 Puck PBRF K-40 pCi/g 8.70E+00 6.80E+00 1.70E+00 10.0 0.78 YES N/A PB09-00460 PB09-oo505 4/1612009 Puck PBRF Cs-137 pCi/g 4.ooE-01 5.10E-01 1.40E-01 6.0 1.28 YES N/A PB09-00480 PB09-oo507 412012009 Puck PBRF K-40 pCVg 1.22E+01 1.28E+01 2.80E+00 9.0 1.05 YES NlA PB09-00480 PB09-00507 412012009 Puck PBRF Cs-137 pCVg 2.30E+00 2.50E+00 3.20E-01 14.0 1.09 YES N/A PB09-ooS00 PB09-oo501 4/2112009 Soil PBRF K-40 pCVg 1.S2E+01 1.46E+01 2.20E+00 14.0 0.96 YES N/A PB09-OO500 PB09-00501 4/2112009 Soil PBRF Cs-137 pCVg 1.50E-01 7.50E-02 6.ooE-02 S.O 0.50 YES N/A PB09-oo520 PB09-00521 412212009 Water PBRF K-40 pCi/g
- 4. 1OE-02 4.ooE-01 1.ooE-02 8.0 9.76 NO 002
---~r---
PB09-00520 PB09-00521 4/2312009 Water PBRF K-40 pCVg 1.20E+00 7.40E-01 2.10E+00 1.1 0.62 YES N/A PB09-00540 PB09-oo541 412212009 Water PBRF K-40 pCVg 4.30E-01 3.ooE-01 9.50E-02 9.0 0.70 YES N/A r----
PB09-00541 PB09-oo541 412212009 Water PBRF K-40 pCVg 8.80E-01 6.70E-01 2.20E-01 8.0 0.76 YES NlA r---
PB09-00540 PB09-oo540 412212009 Water PBRF H-3 pCVg
<MDA
<MDA N/A N/A N/A YES NlA
r---
PB09-oo560 PB09-00561 412712009 Water PBRF H-3 pCVg
<MDA
<MDA N/A N/A N/A YES N/A PB09-00560 PB09-00561 412812009 Water PBRF K-40 pCVg 3.40E-01 5.70E-01 1.10E-01 6.0 1.68 YES N/A PB09-00580 PB09-oo581 412912009 Puck PBRF K-40 pCilg 8.30E+00 8.00E+00 2.27E+00 7.0 1.04 YES N/A PB09-oo580 PB09-OO581 412912009 Puck PBRF Cs-137 pCilg 4.50E-01 3.00E-01 1.50E-01 6.0 0.80 YES N/A PB09-00600 PB09-00601 4/2912009 Puck PBRF K-40 pCilg 9.80E+00 7.90E+00 2.53E+00 8.0 0.81 YES NlA -
PB09-00620 PB09-oo621 412912009 Puck PBRF K-40 pCi/g 8.00E+00 4.33E+00 2.70E+00 6.0 0.50 YES NlA PB09-00640 PB09-00641 413012009 Puck PBRF K-40 pCilg 8.00E+00 6.80E+00 2.30E+00 7.0 0.79 YES NlA 1- --
-~ ~------
PB09-oo660 PB09-oo661 S/4I2009 Water PBRF K-40 pCilg
<MDA
<MDA N/A N/A N/A YES NlA 11 INTRA-LABORATORY COMPARISON (REPLICATE) RESULTS Replicate c:
SDR c:
Gamma Log Sample ID Original
.Q Q)
Number Number Number Acquisition Sample Analysis Nuclide Units Original Replicate 2 Sigma "5
Ratio E
SDR-Date Type Performed Result Result Q)
(Original)
(Replicate)
Uncertainty
~
09-By Q)
~
0:::
PB09-OO440 PB09-00441 411412009 Soil PBRF K-40 pCVg 1.80E-01 3.00E-01 7.40E-02 5.0 1.67 YES N/A PB09-00460 PB09-0050S 411612009 Puck PBRF K-40 pCi/g 8.70E+00 6.80E+00 1.70E+00 10.0 0.78 YES N/A PB09-00460 PB09-00505 4/1612009 Puck PBRF Cs-137 pCi/g 4.ooE-01 5.10E-01 1.40E-01 6.0 1.28 YES N/A PB09-00480 PB09-oo507 412012009 Puck PBRF K-40 pCVg 1.22E+01 1.28E+01 2.80E+00 9.0 1.05 YES NlA PB09-00480 PB09-00507 412012009 Puck PBRF Cs-137 pCVg 2.30E+00 2.50E+00 3.20E-01 14.0 1.09 YES N/A PB09-00S00 PB09-00501 4/2112009 Soil PBRF K-40 pCVg 1.S2E+01 1.46E+01 2.20E+00 14.0 0.96 YES N/A PB09-OO500 PB09-00501 4/2112009 Soil PBRF Cs-137 pCVg 1.50E-01 7.50E-02 6.ooE-02 5.0 0.50 YES N/A PB09-oo520 PB09-00521 412212009 Water PBRF K-40 pCi/g
- 4. 1 OE-02 4.ooE-01 1.00E-02 8.0 9.76 NO 002
---~ r----
PB09-00520 PB09-00521 4/2312009 Water PBRF K-40 pCVg 1.20E+00 7.40E-01 2.10E+00 1.1 0.62 YES N/A PB09-00540 PB09-oo541 412212009 Water PBRF K-40 pCilg 4.30E-01 3.ooE-01 9.50E-02 9.0 0.70 YES N/A i-----
PB09-00541 PB09-oo541 412212009 Water PBRF K-40 pCVg 8.80E-01 6.70E-01 2.20E-01 8.0 0.76 YES NlA
~9-00540 r----
PB09-oo540 412212009 Water PBRF H-3 pCVg
<MDA
<MDA N/A N/A N/A YES NlA
I----
PB09-oo560 PB09-00561 412712009 Water PBRF H-3 pCVg
<MDA
<MDA N/A N/A N/A YES N/A PB09-00560 PB09-00561 412812009 Water PBRF K-40 pCVg 3.40E-01 5.70E-01 1.10E-01 6.0 1.68 YES N/A PB09-00580 PB09-oo581 412912009 Puck PBRF K-40 pCilg 8.30E+00 8.00E+00 2.27E+00 7.0 1.04 YES N/A PB09-oo580 PB09-OO581 412912009 Puck PBRF Cs-137 pCilg 4.50E-01 3.00E-01 1.50E-01 6.0 0.80 YES N/A PB09-00600 PB09-00601 4/2912009 Puck PBRF K-40 pCilg 9.80E+00 7.90E+OO 2.53E+00 8.0 0.81 YES NlA --
PB09-00620 PB09-00621 412912009 Puck PBRF K-40 pCi/g 8.00E+00 4.33E+00 2.70E+00 6.0 0.50 YES NlA PB09-00640 PB09-00641 413012009 I
Puck PBRF K-40 pCilg 8.00E+00 6.80E+00 2.30E+00 7.0 0.79 YES NlA 1-- ---
i Water
-~
PB09-oo660 PB09-oo661 5/412009 PBRF K-40 pCilg
<MDA
<MDA N/A N/A N/A YES NlA 11
INTRA-LABORATORY COMPARISON (REPLICATE) RESULTS Replicate c:
SDR c:
Gamma Log Sample 10 Original 0
Q)
Number Acquisition Sample Analysis Original Replicate E
Number Number Nuclide Units 2 Sigma
- J Ratio SDR-Date Type Performed Result Result
'0 Q)
(Original)
(Replicate)
Uncertainty
(/)
~
09 By Q)
~
cr:::
- 11#
PB09-OO660 PB09-00661 5/412009 Water PBRF H3 pCi/ml 1.40E+00 1.38E+00 8.60E-01 3.3 0.99 YES N/A PB09-00680 PB09-00681 51512009 Puck PBRF K-40 pCi/g 7.20E+00 1.05E+01 2.20E+00 7.0 1.46 YES N/A t----
PB09-007oo PB09-oo701 51612009 Puck PBRF K-40 pCi/g 7.40E+00 5.60E+00 1.50E+00 10.0 0.76 YES N/A PB09-oo7oo PB09-oo701 5/612009 Puck PBRF Cs-137 pCi/g 1.90E-01 8.00E-02 1.ooE-01 3.8 0.42 YES N/A PB09-00714 PB09-00721 51612009 Soil PBRF K-40 pCilg 1.68E+01 1.52E+01 3.90E+00 9.0 0.90 YES N/A PB09-00740 PB09-oo741 5/1312009 Soil PBRF K-40 pCi/g 2.84E+00 2.90E+00 8.80E-01 6.0 1.02 YES N/A PB09-00740 PB09-oo741 511312009 Soil PBRF Cs-137 pCilg 1.40E-01 1.50E-01 5.50E-02 5.0 1.07 YES N/A PB09-oo760 PB09-oo761 5/1512009 Water PBRF K-40 pCi/g 5.50E-01 4.90E-01 1.80E-01 6.0 0.89 YES N/A
--,-~-
PB09-OO760 PB09-00761 5/1512009 Water PBRF H3 pCilml
<MDA
<MDA N/A N/A N/A YES N/A PB09-OO780 PB09-00781 5/2612009 125 PBRF K-40 pCi/g 2.07E+01 2.42E+01 6.70E+00 6.0 1.17 YES N/A PB09-oo780 PB09-oo781 512612009 125 PBRF Cs-137 pCi/g 6.93E+00 6.69E+00 1.03E+00 13.0 0.97 YES N/A PB09-OOBOO PB09-00801 512612009 Soil PBRF K-40 pCi/g 8.20E+00 5.80E+00 2.05E+00 8.0 0.71 YES N/A PB09-00800 PB09-00B01 512612009 Soil PBRF Cs-137 pCi/g 1.90E+00 1.60E+00 2.60E+OO 1.5 0.84 YES N/A PB09-00820 PB09-00821 511/1956 Soil PBRF K-40 pCi/g 1.47E+01 1.39E+01 2.30E+00 13.0 0.95 YES N/A
~-
PB09-00840 PB09-00841 512812009 125 PBRF K-40 pCilg 2.D4E+01 2.06E+01 8.34E+OO 5.0 1.01 YES N/A f--
--t----
PB09-00840 PB09-00841 5/2812009 125 PBRF Cs-137 pCilg 1.2DE+01 1.17E+01 1.70E+OO 14.0 0.98 YES N/A
-~
PB09-0860 PB09-0861 6/112009 Soil PBRF K-40 pCi/g 3.20E+00 1.90E+OO 1.40E+00 5.0 0.59 YES N/A PB09-0860 PB09-0861 6/112009 Soil PBRF Cs-137 pCi/g 4.20E-01 5.40E-01 1.30E-01 6.0 1.29 YES N/A PB08-00BB0 PB08-00881 6/312009 Soil PBRF K-40 pCi/g 1.16E+01 1.07E+01 2.00E+OO 12.0 0.92 YES N/A PB08-00880 PB08-00881 61312009 Soil PBRF Cs-137 pCi/g 8.40E-02 9.80E-02 4.20E-02 4.0 1.17 YES NlA PB08-00900 PB08-00901 6/1012009 Soil PBRF K-40 pCi/g 1.SSE+01 1.83E+01 2.70E+00 11.0 1.18 YES NlA 12 INTRA-LABORATORY COMPARISON (REPLICATE) RESULTS Replicate c:
SDR c:
Gamma Log Sample 10 Original 0
Q)
Number Acquisition Sample Analysis Original Replicate E
Number Number Nuclide Units 2 Sigma
- J Ratio SDR-Date Type Performed Result Result
'0 Q)
(Original)
(Replicate)
Uncertainty
(/)
~
09-By Q)
~
cr:::
- 11#
PB09-OO660 PB09-00661 5/412009 Water PBRF H3 pCi/ml 1.40E+00 1.38E+00 8.60E-01 3.3 0.99 YES N/A PB09-00680 PB09-00681 51512009 Puck PBRF K-40 pCi/g 7.20E+00 1.05E+01 2.20E+00 7.0 1.46 YES N/A t-----
PB09-007oo PB09-oo701 51612009 Puck PBRF K-40 pCi/g 7.40E+00 5.60E+00 1.50E+00 10.0 0.76 YES N/A PB09-oo7oo PB09-oo701 5/612009 Puck PBRF Cs-137 pCi/g 1.90E-01 8.00E-02 1.ooE-01 3.8 0.42 YES N/A PB09-00714 PB09-00721 51612009 Soil PBRF K-40 pCilg 1.68E+01 1.52E+01 3.90E+00 9.0 0.90 YES N/A PB09-00740 PB09-oo741 5/1312009 Soil PBRF K-40 pCi/g 2.84E+00 2.90E+00 8.80E-01 6.0 1.02 YES N/A PB09-00740 PB09-oo741 511312009 Soil PBRF Cs-137 pCilg 1.40E-01 1.50E-01 5.50E-02 5.0 1.07 YES N/A PB09-oo760 PB09-oo761 5/1512009 Water PBRF K-40 pCi/g 5.50E-01 4.90E-01 1.80E-01 6.0 0.89 YES N/A
--,-~-
PB09-OO760 PB09-00761 5/1512009 Water PBRF H3 pCilml
<MDA
<MDA N/A N/A N/A YES N/A PB09-OO780 PB09-00781 5/2612009 125 PBRF K-40 pCi/g 2.07E+01 2.42E+01 6.70E+00 6.0 1.17 YES N/A PB09-oo780 PB09-oo781 512612009 125 PBRF Cs-137 pCi/g 6.93E+00 I 6.69E+00 1.03E+00 13.0 0.97 YES N/A PB09-OOBOO PB09-00801 512612009 Soil PBRF K-40 pCi/g 8.20E+00 5.80E+00 2.05E+00 8.0 0.71 YES N/A PB09-008oo PB09-ooB01 512612009 Soil PBRF Cs-137 pCi/g 1.90E+00 1.60E+00 2.60E+00 1.5 0.84 YES N/A PB09-00820 PB09-00821 511/1956 Soil PBRF K-40 pCi/g 1.47E+01 1.39E+01 2.30E+00 13.0 0.95 YES N/A
~-
PB09-00840 PB09-00841 512812009 125 PBRF K-40 pCilg 2.D4E+01 2.06E+01 8.34E+OO 5.0 1.01 YES N/A r--
--1-----
PB09-00840 PB09-oo841 5/2812009 125 PBRF Cs-137 pCilg 1.2DE+01 1.17E+01 1.70E+OO 14.0 0.98 YES N/A
-~
PB09-0860 PB09-0861 6/112009 Soil PBRF K-40 pCi/g 3.20E+00 1.90E+00 1.40E+00 5.0 0.59 YES N/A PB09-0860 PB09-0861 6/112009 Soil PBRF Cs-137 pCi/g 4.20E-01 5.40E-01 1.30E-01 6.0 1.29 YES N/A PB08-00BB0 PB08-00881 6/312009 Soil PBRF K-40 pCi/g 1.16E+01 1.07E+01 2.ooE+OO 12.0 0.92 YES N/A B~~
PB08-00881 61312009 Soil PBRF Cs-137 pCi/g 8.40E-02 9.80E-02 4.20E-02 4.0 1.17 YES NlA B08-oo900 PB08-00901 6/1012009 Soil PBRF K-40 pCi/g 1.SSE+01 1.83E+01 2.70E+00 11.0 1.18 YES NlA 12
INTRA-LABORATORY COMPARISON (REPLICATE) RESULTS Replicate c
SDR c:
Gamma Log Sample 10 Original B
Q)
Number Number Number Acquisition Sample Analysis Nuclide Units Original Replicate 2 Sigma
- I Ratio E
SDR-Date Type Performed Result Result (5
Q)
(Original)
(Replicate)
Uncertainty (J) l!!
09 By Q)
Jl 0:::
PBOS-00900 PBOS-00901 611012009 Soil PBRF Cs-137 pCi/g 5.10E+01 5.22E+01 1.S0E+00 57.0 1.02 YES N/A PBOS-00920 PBOS-00921 611512009 Soil PBRF K-40 pCi/g 1.4SE+01 1.57E+01 2.22E+00 13.0 1.06 YES N/A PBOS-00939 PB08-oo940 611612009 Puck PBRF K-40 pCi/g 9.30E+00 9.30E+00 2.30E+00 S.O 1.00 YES N/A PB08-00939 PB08-00940 611612009 Puck PBRF Cs-137 pCi/g 6.30E+00 5.S0E+00 4.95E+00 2.5 0.92 YES N/A PB08-00960 PB08-00961 611612009 Soil PBRF K-40 pCi/g 1.45E+01 1.32E+01 2.10E+00 14.0 0.91 YES N/A PB08-00980 PB08-009S1 612312009 Soil PBRF K-40 pCi/g 1.55E+01 1.57E+01 2.32E+00 13.0 1.01 YES N/A PBOS-00980 PB08-00981 612312009 Soil PBRF Cs-137 pCi/g 1.40E+00 1.50E+00 1.S0E-01 16.0 1.07 YES N/A PBOS-00999 PBOS-0010oo 612512009 Soil PBRF K-40 pCi/g 1.46E+01 1.71 E+01 2.20E+00 13.0 1.17 YES N/A PBOS-001020 PBOS-001021 612612009 Soil PBRF K-40 pCi/g 1.76E+01 1.95E+01 1.77E+00 20.0 1.11 YES NlA PBOS-001040 PBOS-001041 613012009 Water PBRF K-40 pCi/g 6.00E-01 7.60E-01 2.ooE-01 6.0 1.27 YES N/A PBOS-001040 PB08-001041 613012009 Water PBRF Cs-137 pCi/g 6.ooE-02 3.00E-02 2.34E-02 5.0 0.50 YES N/A PB09-01060 PB09-01061 71212009 Water PBRF H3 pCi/ml
<MDA
<MDA N/A N/A N/A YES N/A PB09-01060 PB09-01061 71212009 Water PBRF K-40 pCi/g 4.80E-01 5.30E-01 1.70E-01 6.0 1.10 YES N/A PB09-01060 PB09-01061 71212009 Water PBRF Cs-137 pCi/g 3.30E-02 2.40E-02 1.50E-02 4.0 0.73 YES N/A PB09-01060 PB09-01061 71212009 Water PBRF C0-60 pCi/g 1.ooE-01 1.50E-02 1.90E-02 11.0 0.15 NO 003 PB09-01060 PB09-01061 71812009 Water PBRF Co-60 pCi/g
<MDA
<MDA N/A N/A N/A YES N/A PB09-010S0 PB09-010S1 7f712009 Soil PBRF K-40 pCi/g 1.63E+01 1.50E+01 2.10E+00 16.0 0.92 YES NlA PB09-01100 PB09-01101 7/9/2009 Soil PBRF K-40 pCi/g 1.67E+01 1.47E+01 2.40E+00 14.0 O.SS YES N/A 13 I
INTRA-LABORATORY COMPARISON (REPLICATE) RESULTS Replicate c
SDR c:
Gamma Log Sample 10 Original B
Q)
Number Number Number Acquisition Sample Analysis Nuclide Units Original Replicate 2 Sigma
- I Ratio E
SDR-Date Type Performed Result Result (5
Q)
(Original)
(Replicate)
Uncertainty (J) l!!
09-By Q)
Jl 0:::
PBOS-00900 OS-00901 611012009 Soil PBRF Cs-137 pCi/g 5.10E+01 5.22E+01 1.S0E+00 57.0 1.02 YES N/A PBOS-00920 PBOS-00921 611512009 Soil PBRF K-40 pCi/g ~
1.57E+01 2.22E+00 -
13.0 1.06 YES PBOS-00939 PB08-oo940 6116.... """
Puck PBRF K~~
9.30E+00 2.30E+00 S.O 1.00 YES N/A PB08-00939 PB08-00940 611612009 Puck PBRF Cs-137..
pCi/g
+00 5.S0E+00 4.95E+00 2.5 0.92 YES N/A PB08-00960 PB08-00961 611612009 0 PBRF K-40 pCi/g 1.45E+01 1.32E+01 2.10E+00 14.0 0.91 YES N/A PB08-00980 PB08-009S1 612312009 PBRF K-40 pCi/g 1.55E+01 1.57E+01 2.32E+00 13.0 1.01 YES N/A PBOS-00980 PB08-00981 612312009 Soil I
PBRF Cs-137 pCi/g 1.40E+00 1.50E+00 1.S0E-01 16.0 1.07 YES N/A PBOS-00999 PBOS-0010oo 612512009 Soil PBRF K-40 pCi/g 1.46E+01 1.71 E+01 2.20E+00 13.0 1.17 YES N/A PBOS-001020 PBOS-001021 612612009 Soil PBRF K-40 pCi/g 1.76E+01 1.95E+01 1.77E+00 2
.1 YES NlA PBOS-001040 PBOS-001041 613012009 Water PBRF K-40 pCi/g 7.60E-01 2.ooE-01
- 6.
YES N/A PBOS-001040 PB08-001041 613012009 Water PBRF Cs-137 pCi/g 6.ooE-02 3.00E-02 2.34E-02
- 5.
50 YES N/A PB09-01060 PB09-01061 71212009 Water F
H3 pCi/
<MDA N/A NI IA YES N/A PB09-01060 PB09-01061 71212009 Water PBRF K-40 pCi/g 4.80E-01 5.30E-01 1.70E-01 6.0 1.10 YES N/A PB09-01060 PB09-01061 71212009 Water PBRF Cs-137 pCi/g 3.30E-02 2.40E-02 1.50E-02 4.0 0.73 YES N/A 09-01060 PB09-01061 71212009 Water PBRF C0-60 pCi/g 1.ooE-01 1.50E-02 1.90E-02 11.0 0.15 NO 003 PB09-01060 PB09-01061 71812009 Water PBRF Co-60 pCi/g
<MDA
<MDA N/A N/A N/A YES N/A I
PB09-010S0 PB09-010S1 7f712009 Soil PBRF K-40 pCi/g 1.63E+0~ 1.50E+01 2.10E+00 16.0 0.92 YES NlA PB09-01100 PB09-01101 7/9/2009 Soil PBRF K-40 pCi/g 1.67E+0~ 1.47E+01 2.40E+00 14.0 O.
N/A 13
INTRA-LABORATORY COMPARISON (REPLICATE) RESULTS I
I Replicate c:
SDR c:
Gamma Log SamplelD Original 0
(1)
Number Acquisition Sample Analysis Original Replicate
- l E
Number Number Nuclide Units 2 Sigma
- J Ratio SDR-Date Type Performed Result Result (5
(1)
(Original)
(Replicate)
Uncertainty (f)
~
09 By (1) if a::
PB09-01100 PB09-01101 719/2009 Soil PBRF K-40 pCilg 1.30E-01 7.ooE-02 5.50E-02 5.0 0.54 YES N/A PB09-01120 PB09-01121 7/1312009 Soil PBRF K-40 pCi/g 1.66E+01 1.66E+01 2.10E+00 16.0 1.00 YES N/A PB09-01140 PB09-01141 7/1312009 Soil PBRF K-40 pCilg 3.ooE+00 3.20E+00 8.50E-01 7.0 1.07 YES N/A PB09-01160 PB09-01161 7/1612009 Puck PBRF K-40 pCilg 8.90E+00 6.80E+00 2.30E+00 8.0 0.76 YES NlA PB09-01160 PB09-01161 7/1612009 Puck PBRF K-40 pCilg 3.00E-01 3.30E-01 1.10E-01 5.0 1.10 YES N/A PB09-01180 PB09-01181 7/2012009 Soil PBRF K-40 pCilg 1.74E+01 1.76E+01 2.20E+00 16.0 1.01 YES N/A PB09-012oo PB09-01201 7/2412009 Soil PBRF K-40 pCilg 1.45E+01 1.19E+01 2.20E+00 13.0 0.82 YES N/A PB09-01200 PB09-01201 7/2412009 Soil PBRF Cs-137 pCilg 8.30E+00 8.70E+00 4.70E-01 35.0 1.05 YES N/A PB09-01200 PB09-01201 712412009 Soil PBRF Co-60 pCilg 2.00E-01 1.00E-01 6.00E-02 7.0 0.50 YES N/A PB09-01220 PB09-01221 7/2712009 Water PBRF K-40 pCilg 4.80E-01 6.80E-01 1.30E-01 7.0 1.42 YES N/A PB09-01220 PB09-01221 7/2712009 Water PBRF H3 pCilml
<MDA
<MDA N/A N/A N/A YES N/A PB09-01240 PB09-01241 7/2812009 125 PBRF K-40 pCi/g 2.53E+01 1.98E+01 5.70E+00 9.0 0.78 YES N/A PB09-01240 PB09-01241 7/2812009 125 PBRF Cs-137 pCilg 8.80E+00 9.50E+00 9.60E+00 1.8 1.08 YES N/A PB09-01260 PB09-01261 7/2812009 Soil PBRF K-40 pCi/g 1.73E+01 1.48E+01 3.20E+00 11.0 0.86 YES N/A PB09-01280 PB09-01281 7/2912009 125 PBRF K-40 pCilg 2.02E+01 2.08E+01 5.70E+00 7.0 1.03 YES N/A f-PB09-01280 PB09-01281 7/2912009 125 PBRF Cs-137 pCilg 6.30E+00 5.80E+00 8.80E-01 14.0 0.92 YES N/A PB09-01300 PB08-oo1301 7/2912009 Soil PBRF K-40 pCilg 1.39E+01 1.61E+01 3.00E+00 9.0 1.16 YES N/A PB09-01300 PB08-OO1301 712912009 Soil PBRF Cs-137 pCilg 2.86E+00 2.90E+00 3.62E-01 16.0 1.01 YES N/A PB08-001320 PB08-001321 7/3012009 Water PBRF K-40 pCilg 6.10E-01 4.00E-01 1.80E-01 7.0 0.66 YES N/A 14 INTRA-LABORATORY COMPARISON (REPLICATE) RESULTS Replicate c:
SDR c:
Gamma Log SamplelD Original 0
(1)
Number Acquisition Sample Analysis Original Replicate
- l E
Number Number Nuclide Units 2 Sigma
- J Ratio SDR-Date Type Performed Result Result (5
(1)
(Original)
(Replicate)
Uncertainty (f)
~
09-By (1) if a::
PB09-01100 PB09-01101 719/2009 Soil PBRF K-40 pCilg 1.30E-01 7.ooE-02 5.50E-02 5.0 0.54 YES N/A PB09-01120 PB09-01121 7/1312009 Soil PBRF K-40 pCi/g 1.66E+01 1.66E+01 2.10E+00 16.0 1.00 YES N/A PB09-01140 PB09-01141 7/1312009 Soil PBRF K-40 pCilg 3.ooE+00 3.20E+00 8.50E-01 7.0 1.07 YES N/A PB09-01160 PB09-01161 7/1612009 Puck PBRF K-40 pCilg 8.90E+00 6.80E+00 2.30E+00 8.0 0.76 YES NlA PB09-01160 PB09-01161 7/1612009 Puck PBRF K-40 pCilg 3.00E-01 3.30E-01 1.10E-01 5.0 1.10 YES N/A PB09-01180 PB09-01181 7/2012009 Soil PBRF K-40 pCilg 1.74E+01 1.76E+01 2.20E+00 16.0 1.01 YES N/A I-----
PB09-012oo PB09-01201 7/2412009 Soil PBRF K-40 pCilg 1.45E+01 1.19E+01 2.20E+00 13.0 0.82 YES N/A PB09-01200 PB09-01201 7/2412009 Soil PBRF Cs-137 pCilg 8.30E+00 8.70E+00 4.70E-01 35.0 1.05 YES N/A PB09-01200 PB09-01201 712412009 Soil PBRF Co-60 pCilg 2.00E-01 1.00E-01 6.00E-02 7.0 0.50 YES N/A PB09-01220 PB09-01221 7/2712009 Water PBRF K-40 pCilg 4.80E-01 6.80E-01 1.30E-01 7.0 1.42 YES N/A PB09-01220 PB09-01221 7/2712009 Water PBRF H3 pCilml
<MDA
<MDA N/A N/A N/A YES N/A PB09-01240 PB09-01241 7/2812009 125 PBRF K-40 pCi/g 2.53E+01 1.98E+01 5.70E+00 9.0 0.78 YES N/A PB09-01240 PB09-01241 7/2812009 125 PBRF Cs-137 pCilg 8.80E+00 9.50E+00 9.60E+00 1.8 1.08 YES N/A PB09-01260 PB09-01261 7/2812009 Soil PBRF K-40 pCi/g 1.73E+01 1.48E+01 3.20E+00 11.0 0.86 YES N/A PB09-01280 PB09-01281 7/2912009 125 PBRF K-40 pCilg 2.02E+01 2.08E+01 5.70E+00 7.0 1.03 YES N/A PB09-01280 PB09-01281 7/2912009 125 PBRF Cs-137 pCilg 6.30E+00 5.80E+00 8.80E-01 14.0 0.92 YES N/A PB09-01300 PB08-oo1301 7/2912009 Soil PBRF K-40 pCilg 1.39E+01 1.61E+01 3.00E+00 9.0 1.16 YES N/A I PB09-01300 PB08-OO1301 712912009 Soil PBRF Cs-137 pCilg 2.86E+00 2.90E+00 3.62E-01 16.0 1.01 YES N/A PB08-001320 PB08-001321 7/3012009 Water PBRF K-40 pCilg 6.10E-01 4.00E-01 1.80E-01 7.0 0.66 YES N/A 14
INTRA-LASORATORY COMPARISON (REPLICATE) RESULTS Replicate c
SDR c
Gamma Log SamplelD Original B
Q)
Number Number Number Acquisition Sample Analysis Nuclide Units Original Replicate 2 Sigma
- I Ratio E
SDR-Date Type Performed Result Result (5
Q)
(Original)
(Replicate)
Uncertainty III
~
09 By Q)
Jl c:::
PB08-001320 PB08-001321 7/3012009 Water PBRF H3 pCi/ml 1.5OE+00 1.40E+00 B.70E-01 3.7 O.BB YES N/A PB08-001340 PBOB-001341 7/3012009 Soil PBRF K-40 pCi/g 1.5OE+01 1.73E+01 2.20E+00 15.0 1.08 YES N/A PBOB-001340 PB08-OO1341 713012009 Soil PBRF Cs-137 pCi/g B.09E+01 B.19E+01 2.40E+00 67.0 1.01 YES N/A
--f PB08-001340 PB08-001341 7/3012009 Soil PBRF Co-50 pCi/g 1.10E+00 1.13E+00 1.30E-01 17.0 1.03 YES N/A PBOB-001360 PB08-oo1361 7/3012009 Soil PBRF K-40 pCi/g 1.59E+01 1.43E+01 2.25E+00 14.0 0.90 YES N/A PB08-OO1360 PB08-oo1361 7/3012009 Soil PBRF Cs-137 pCi/g 1.07E+01 1.07E+01 5.50E-01 39.0 1.00 YES N/A PB08-OO1360 PB08-001361 7/3012009 Soil PBRF Co-50 pCi/g 1.70E-01 2.60E-01 5.ooE-02 7.0 1.53 YES NlA f
PB08-OO1380 PB08-oo1381 7/3112009 Soil PBRF K-40 pCi/g 2.07E+01 1.68E+01 3.60E+00 12.0 0.81 YES N/A PB08-oo1400 PB08-oo1401 7/3112009 Soil PBRF K-40 pCilg 1.30E+01 1.47E+01 2.90E+00 9.0 1.13 YES N/A r---
PB08-OO1420 PB08-001421 713112009 Soil PBRF K-40 pCi/g 1.19E+01 1.21E+01 2.40E+00 10.0 1.02 YES N/A f------
PB09-01440 PB09-01441 8/312009 Soil PBRF K-40 pCi/g 2.00E+01 1.98E+01 3.70E+00 11.0 0.96 YES N/A PB09-01460 PB09-01461 8/412009 Soil PBRF K-40 pCi/g 1.31E+01 1.44E+01 3.ooE+00 9.0 1.10 YES NlA PB09-01460 PB09-01461 8/412009 Soil PBRF Cs-137 pCilg 1.BOE-01 2.20E-01 9.00E-02 4.0 1.22 YES NlA PB09-01480 PB09-01481 8/412009 Soil PBRF K-40 pCi/g 1.54E+01 1.46E+01 3.33E+00 9.0 0.95 YES N/A PB09-01500 PB09-01501 81512009 Soil PBRF K-40 pCilg 1.53E+01 1.B4E+01 3.22E+00 10.0 1.07 YES N/A PB09-01520 PB09-01521 B/512009 Soil PBRF K-40 pCilg 9.10E+00 B.5OE+OO 2.40E+00 B.O 0.95 YES N/A PB09-01520 PB09-01521 8/512009 Soil PBRF Cs-137 pCi/g 2.80E-01 2.95E-01 1.10E-01 5.0 1.05 YES N/A PB09-01540 PB09-01541 8/612009 Soil PBRF K-40 pCilg 1.B4E+01 1.66E+01 3.40E+00 10.0 1.01 YES N/A
~--
PB09-01560 PB09-01561 81612009 Soil PBRF K-40 pCi/g 1.81E+01 1.31E+01 3.40E+00 11.0 0.72 YES N/A 15 INTRA-LASORA TORY COMPARISON (REPLICATE) RESULTS Replicate c
SDR c
Gamma Log SamplelD Original B
Q)
Number Number Number Acquisition Sample Analysis Nuclide Units Original Replicate 2 Sigma
- I Ratio E
SDR-Date Type Performed Result Result (5
Q)
(Original)
(Replicate)
Uncertainty III
~
09-By Q)
Jl c:::
PB08-001320 PB08-001321 7/3012009 Water PBRF H3 pCi/ml 1.5OE+
1.40E+00 B.70E-01 3.7 O.BB YES N/A PB08-001340 PBOB-001341 7/3012009 Soil PBRF K-40 pCi/g 1.5OE+01 1.73E+01 2.20E+00 15.0 1.08 YES N/A PBOB-001340 PB08-OO1341 713012009 Soil PBRF Cs-137 pCi/g B.09E+01 B.19E+01 2.40E+00 67.0 1.01 YES N/A PB08-001340 PB08-001341 7/3012009 Soil PBRF Co-50 pCi/g 1.10E+00 1.13E+00 1.30E-01 17.0 1.03 YES N/A PBOB-001360 PB08-oo1361 7/3012009 Soil PBRF K-40 pCi/g 1.59E+01 1.43E+01 2.25E+00 14.0 0.90 YES N/A PB08-OO1360 PB08-oo1361 7/3012009 Soil PBRF Cs-137 pCi/g 1.07E+01 1.07E+01 5.50E-01 39.0 1.00 YES N/A PB08-OO1360 PB08-001361 7/3012009 Soil PBRF Co-50 pCi/g 1.70E-01 2.60E-01 5.ooE-02 7.0 1.53 YES NlA PB08-OO1380 PB08-oo1381 7/3112009 Soil PBRF K-40 pCi/g 2.07E+01 1.68E+01 3.60E+00 12.0 0.81 YES N/A PB08-oo1400 PB08-oo1401 7/3112009 Soil PBRF K-40 pCilg 1.30E+01 1.47E+01 2.90E+00 9.0 1.13 YES N/A PB08-OO1420 PB08-001421 713112009 Soil PBRF K-40 pCi/g 1.19E+01 1.21E+01 2.40E+00 10.0 1.02 YES N/A PB09-01440 PB09-01441 8/312009 Soil PBRF K-40 pCi/g 2.00E+01 1.98E+01 3.70E+00 11.0 0.96 YES N/A PB09-01460 PB09-01461 8/412009 Soil PBRF K-40 pCi/g 1.31E+01 1.44E+01 3.ooE+00 9.0 1.10 YES NlA PB09-01460 PB09-01461 8/412009 Soil PBRF Cs-137 pCilg 1.BOE-01 2.20E-01 9.00E-02 4.0 1.22 YES NlA PB09-01480 PB09-01481 8/412009 Soil PBRF K-40 pCi/g 1.54E+01 1.46E+01 3.33E+00 9.0 0.95 YES N/A 1----
PB09-01500 PB09-01501 81512009 Soil PBRF K-40 pCilg 1.53E+01 1.B4E+01 3.22E+00 10.0 1.07 YES N/A PB09-01520 PB09-01521 B/512009 Soil PBRF K-40 pCilg 9.10E+00 B.5OE+OO 2.40E+00 B.O 0.95 YES N/A PB09-01520 PB09-01521 8/512009 Soil PBRF Cs-137 pCi/g 2.80E-01 2.95E-01 1.10E-01 5.0 1.05 YES N/A PB09-01540 PB09-01541 8/612009 Soil PBRF K-40 pCilg 1.B4E+01 1.66E+01 3.40E+00 10.0 1.01 YES N/A PB09-01560 PB09-01561 81612009 Soil PBRF K-40 pCi/g 1.81E+01 1.31E+01 3.40E+00 11.0 0.72 YES N/A 15
INTRA-LABORATORY COMPARISON (REPLICATE) RESULTS Replicate c:
SDR c:
Gamma Log Sample 10 Original 0
CD Number Acquisition Sample Analysis Original Replicate
- p E
Number Number Nuclide Units 2 Sigma
- J Ratio SDR~
Date Type Performed Result Result
'0
~
(Original)
(Replicate)
Uncertainty 1/1 09~
By
!if PB09-01580 PB09-01581 8nl2009 Soil PBRF K-40 pCilg 1.69E+01 2.15E+01 3.60E+00 9.0 1.27 YES NfA PB09-01600 PB09-01601 Sn12oo9 Soil PBRF K-40 pCi/g 1.49E+01 1.65E+01 3.ooE+00 10.0 1.11 YES N/A PB~01620 PB09-01621 Snt2009 Soil PBRF K-40 pCi/g 1.27E+01 1.48E+01 2.90E+00 9.0 1.17 YES N/A
~...
PB09-01620 PB09-01621 Snt2009 Soil PBRF Cs-137 pCi/g 1.90E-01 1.70E-01 9.20E-02 4.0 0.S9 YES N/A PB~01639 PB~01640 S/1012009 Soil PBRF K-40 pCi/g 1.37E+01 1.22E+01 2.95E+00 9.0 0.S9 YES N/A
.~.... -
PB09-01659 PB09-01660 S/1012009 Soil PBRF K-40 pCi/g 1.51E+01 1.S2E+01 3.02E+00 10.0 1.21 YES N/A PB09-01680 PB~016S1 S/1012009 Water PBRF K40 pCi/g
<MDA
<MDA N/A N/A N/A YES N/A
.~.-
PB~016S0 PB~01681 S/1012009 Water PBRF H3 pCi/ml
<MDA
<MDA N/A N/A N/A YES N/A P~01700 PB09-01701 8/1112009 Soil PBRF K-40 pCilg 1.14E+01 1.21E+01 2.S0E+00 S.O 1.06 YES N/A PB09-01720 PB09-01721 S/1112009 Soil PBRF K40 pCi/g 9.99E+00 S.30E+OO 3.34E+00 6.0 0.S3 YES N/A
...~
PB~01nO PB09-01721 8/1112009 Soil PBRF Cs-137 pCilg 2.70E-01 2.70E-01 9.90E-02 5.0 1.00 YES N/A
.~.
PB09-01740 PB09-01741 S/12/2OO9 Soil PBRF K-40 pCi/g 1.53E+01 1.64E+01 3.44E+00 9.0 1.07 YES N/A
.~.
PB09-01740 PB~01741 8/1212009 Soil PBRF Cs-137 pCilg 4.10E-01 4.ooE-01 1.40E-01 6.0 0.98 YES N/A PB~01760 PB09-01761 8112/2009 Soil PBRF K-40 pCi/g 1.77E+01 1.54E+01 3.50E+00 10.0 0.87 YES N/A
.~.-
PB09-01760 PB09-01761 8/12/2009 Soil PBRF Cs-137 pCi/g 4.60E-01 4.80E-01 1.40E-01 7.0 1.04 YES N/A PB09-01780 PB~01781 S/1312009 Soil PBRF K-40 pCi/g 1.32E+01 1.34E+01 2.70E+00 10.0 1.02 YES N/A PB09-018oo PB09-01801 811312009 Soil PBRF K-40 pCi/g 1.49E+01 1.69E+01 2.98E+00 10.0 1.13 YES N/A PB09-01S20 PB09-01S21 8/1412009 Soil PBRF K-40 pCi/g 1.59E+01 1.17E+01 3.13E+00 10.0 0.74 YES N/A PB09-01840 PB~01841 811412009 Soil PBRF K40 pCi/g 1.99E+01 1.51E+01 3.70E+00 11.0 0.76 YES N/A 16 I
INTRA-LABORATORY COMPARISON (REPLICATE) RESULTS Replicate c:
SDR c:
Gamma Log Sample 10 Original 0
CD Number Acquisition Sample Analysis Original Replicate
- p E
Number Number Nuclide Units 2 Sigma
- J Ratio SDR~
Date Type Performed Result Result
'0
~
(Original)
(Replicate)
Uncertainty 1/1 09~
By
!if PB09-01580 PB09-01581 8nl2009 Soil PBRF K-40 pCilg 1.69E+01 2.15E+01 3.60E+00 9.0 1.27 YES NfA r***..
PB09-01600 PB09-01601 Sn12oo9 Soil PBRF K-40 pCi/g 1.49E+01 1.65E+01 3.ooE+00 10.0 1.11 YES N/A PB~01620 PB09-01621 Snt2009 Soil PBRF K-40 pCi/g 1.27E+01 1.48E+01 2.90E+00 9.0 1.17 YES N/A
~.
PB09-01620 PB09-01621 Snt2009 Soil PBRF Cs-137 pCi/g 1.90E-01 1.70E-01 9.20E-02 4.0 0.S9 YES N/A f----.... -..
PB~01639 PB~01640 S/1012009 Soil PBRF K-40 pCi/g 1.37E+01 1.22E+01 2.95E+00 9.0 0.S9 YES N/A PB09-01659 PB09-01660 S/1012009 Soil PBRF K-40 pCi/g 1.51E+01 1.S2E+01 3.02E+00 10.0 1.21 YES N/A PB09-01680 PB~016S1 S/1012009 Water PBRF K40 pCi/g
<MDA
<MDA N/A N/A N/A YES N/A PB~016S0 PB~01681 S/1012009 Water PBRF H3 pCi/ml
<MDA
<MDA N/A N/A N/A YES N/A P~01700 PB09-01701 8/1112009 Soil PBRF K-40 pCilg 1.14E+01 1.21E+01 2.S0E+00 S.O 1.06 YES N/A PB09-01720 PB09-01721 S/1112009 Soil PBRF K40 pCi/g 9.99E+00 S.30E+OO 3.34E+00 6.0 0.S3 YES N/A
.. ~
PB~01nO PB09-01721 8/1112009 Soil PBRF Cs-137 pCilg 2.70E-01 2.70E-01 9.90E-02 5.0 1.00 YES N/A PB09-01740 PB09-01741 S/12/2OO9 Soil PBRF K-40 pCi/g 1.53E+01 1.64E+01 3.44E+00 9.0 1.07 YES N/A PB09-01740 PB~01741 8/1212009 Soil PBRF Cs-137 pCilg 4.10E-01 4.ooE-01 1.40E-01 6.0 0.98 YES N/A PB~01760 PB09-01761 8112/2009 Soil PBRF K-40 pCi/g 1.77E+01 1.54E+01 3.50E+00 10.0 0.87 YES N/A PB09-01760 PB09-01761 8/12/2009 Soil PBRF Cs-137 pCi/g 4.60E-01 4.80E-01 1.40E-01 7.0 1.04 YES N/A PB09-01780 PB~01781 S/1312009 Soil PBRF K-40 pCi/g 1.32E+01 1.34E+01 2.70E+00 10.0 1.02 YES N/A PB09-018oo PB09-01801 811312009 Soil PBRF K-40 pCi/g 1.49E+01 1.69E+01 2.98E+00 10.0 1.13 YES N/A PB09-01S20 PB09-01S21 8/1412009 Soil PBRF K-40 pCi/g 1.59E+01 1.17E+01 3.13E+00 10.0 0.74 YES N/A 1----..
PB09-01840 PB~01841 811412009 Soil PBRF K40 pCi/g 1.99E+01 1.51E+01 3.70E+00 11.0 0.76 YES N/A 16
INTRA*LASORATORY COMPARISON (REPLICATE) RESULTS Replicate c:
SDR c:
Gamma Log SamplelD Original 0
Q)
Number Acquisition Sample Analysis Original Replicate
- .;:::2 E
Number Number Nuclide Units 2 Sigma
- I RatiO SDR-Date Type Performed Result Result 15 Q)
(Original)
(Replicate)
Uncertainty U)
I!:!
09 By Q)
- il 0:::
PB09-01860 PB09-01861 8/1712009 Soil PBRF K-40 pCi/g 1.56E+01 1.53E+01 2.98E+00 10.0 0.98 YES N/A PB09-01880 PB09-01881 8/1812009 Soil PBRF K-40 pCi/g 1.89E+01 1.68E+01 3.40E+00 11.0 0.89 YES N/A PB09-01900 PB09-01901 811812009 Soil PBRF K-40 pCi/g 2.10E+01 1.79E+01 3.50E+00 12.0 0.85 YES N/A PB09-01900 PB09-01901 8/1812009 Soil PBRF Cs-137 pCi/g 6.40E+00 6.10E+00 5.30E+00 2.4 0.95 YES N/A PB09-01920 PB09-01921 8/1912009 Soil PBRF K-40 pCi/g 1.57E+01 1.54E+01 3.30E+00 10.0 0.98 YES N/A PB09-01920 PB09-01921 811912009 Soil PBRF Cs-137 pCi/g 4.60E+00 4.80E+00 4.70E-01 20.0 1.04 YES N/A PB09-01940 PB09-01941 8/1912009 Soil PBRF K-40 pCi/g 1.87E+01 2.09E+01 3.60E+00 10.0 1.12 YES N/A PB09-01959 PB09-01960 8/1912009 Water PBRF K-40 pCi/g 6.4DE+00 6.4DE+00 7.ooE-01 18.0 1.00 YES N/A
.._......f-.
PB09-01959 PB09-01960 8/1912009 Water PBRF Cs-137 pCi/g 9.80E-01 1.ooE+00 7.70E-02 25.0 1.02 YES N/A PB09-01980 PB09-01981 812012009 Soil PBRF K-40 pCi/g 1.59E+01 1.17E+01 3.30E+00 10.0 0.74 YES N/A PB09-02oo0 PB09-02oo1 812112009 Soil PBRF K-40 pCi/g 2.54E+01 2.59E+01 3.80E+OO 13.0 1.02 YES N/A PB09-02020 PB09-02021 812412009 Soil PBRF K-40 pCi/g 1.78E+01 1.44E+01 3.23E+00 11.0 0.81 YES N/A PB09-02020 PB09-02021 812412009 Soil PBRF Cs-137 pCi/g 1.56E+01 1.63E+01 8.60E-01 36.0 1.04 YES N/A PB09-02040 PB09-02041 8/2512009 Soil PBRF K-40 pCilg 1.60E+01 1.41E+01 3.20E+00 10.0 0.88 YES N/A I
PB09-02040 PB09-02041 8/2512009 Soil PBRF Cs-137 pCi/g 3.70E-01 4.90E-01 1.22E-01 6.0 1.32 YES N/A PB09-02060 PB09-02061 812612009 Soil PBRF K-40 pCi/g 1.55E+01 1.4BE+01
- 3. 1OE+oo 10.0 0.95 YES N1A '
PB09-02080 PB09-02081 8/2512009 Soil PBRF K-40 pCi/g 1.56E+01 2.00E+01 3.40E+00 9.0 1.28 YES N1A PB09-02080 PB09-02081 812512009 Soil PBRF Cs-137 pCilg 3.50E-01 2.90E-01 1.30E-01 5.0 0.83 YES N1A 17 INTRA*LASORA TORY COMPARISON (REPLICATE) RESULTS Replicate c:
SDR c:
Gamma Log SamplelD Original 0
Q)
Number Acquisition Sample Analysis Original Replicate
- .;:::2 E
Number Number Nuclide Units 2 Sigma
- I RatiO SDR-Date Type Performed Result Result 15 Q)
(Original)
(Replicate)
Uncertainty U)
I!:!
09-By Q)
- il 0:::
PB09-01860 PB09-01861 8/1712009 Soil PBRF K-40 pCi/g 1.56E+01 1.53E+01 2.98E+00 10.0 0.98 YES N/A PB09-01880 PB09-01881 8/1812009 Soil PBRF K-40 pCi/g 1.89E+01 1.68E+01 3.40E+00 11.0 0.89 YES N/A
~----
PB09-01900 PB09-01901 811812009 Soil PBRF K-40 pCi/g 2.10E+01 1.79E+01 3.50E+00 12.0 0.85 YES N/A
1---
PB09-01900 PB09-01901 8/1812009 Soil PBRF Cs-137 pCi/g 6.40E+00 6.10E+00 5.30E+00 2.4 0.95 YES N/A PB09-01920 PB09-01921 8/1912009 Soil PBRF K-40 pCi/g 1.57E+01 1.54E+01 3.30E+00 10.0 0.98 YES N/A PB09-01920 PB09-01921 811912009 Soil PBRF Cs-137 pCi/g 4.60E+00 4.80E+00 4.70E-01 20.0 1.04 YES N/A PB09-01940 PB09-01941 8/1912009 Soil PBRF K-40 pCi/g 1.87E+0~ 2.09E+01 3.60E+00 10.0 1.12 YES N/A PB09-01959 PB09-01960 8/1912009 Water PBRF K-40 pCi/g 6.4DE+00 6.4DE+00 7.ooE-01 18.0 1.00 YES N/A PB09-01959 PB09-01960 8/1912009 Water PBRF Cs-137 pCi/g 9.80E-01 1.ooE+00 7.70E-02 25.0 1.02 YES N/A PB09-01980 PB09-01981 812012009 Soil PBRF K-40 pCi/g 1.59E+01 1.17E+01 3.30E+00 10.0 0.74 Y~ N/A 1----" -------
1----
PB09-02oo0 PB09-02oo1 812112009 Soil PBRF K-40 pCi/g E+01 2.59E+01 3.80E+OO 13.0 1.02 YES N/A PB09-02020 PB09-02021 812412009 Soil PBRF K-40 pCi/g 1.78E+01 1.44E+01 3.23E+00 11.0 0.81 YES N/A PB09-02020 PB09-02021 812412009 Soil PBRF Cs-137 pCi/g 1.56E+01 1.63E+01 8.60E-01 36.0 1.04 YES N/A PB09-02040 PB09-02041 8/2512009 Soil PBRF K-40 pCilg 1.60E+01 1.41E+01 3.20E+00 10.0 0.88 YES N/A PB09-02040 PB09-02041 8/2512009 Soil PBRF Cs-137 pCi/g 3.70E-01 4.90E-01 1.22E-01 6.0 1.32 YES N/A PB09-02060 PB09-02061 812612009 Soil PBRF K-40 pCi/g 1.55E+01 1.4BE+01
- 3. 1 OE+oo 10.0 0.95 YES N1A --
PB09-02080 PB09-02081 8/2512009 Soil PBRF K-40 pCi/g 1.56E+01 2.00E+01 3.40E+00 9.0 1.28 YES N1A PB09-02080 PB09-02081 812512009 Soil PBRF Cs-137 pCilg 3.50E-01 2.90E-01 1.30E-01 5.0 0.83 YES N1A 17
INTRA-LABORATORY COMPARISON (REPLICATE) RESULTS Replicate c:
C SDR Gamma Log Sample 10 Original
.Q Q)
Number Number Number Acquisition Sample Analysis Nuclide Units Original Replicate 2 Sigma "5
Ratio E
SDR-Date Type Performed Result Result (5
~
(Original)
(Replicate)
Uncertainty III 09 By Q)
If e:::
PB09-02100 PB09-02101 812512009 Soil PBRF K-40 pCi/g 1.79E+01 1.33E+01 3.40E+00 11.0 0.74 YES N/A 1----- ----
PB09-02100 PB09-02101 812512009 Soil PBRF Cs-137 pCi/g 3.80E-01 2.60E-01 1.24E-01 6.0 0.68 YES N/A
-~
PB09-02120 PB09-02121 812612009 Soil PBRF K-40 pCilg 1.76E+01 1.41E+01 3.20E+00 11.0 0.80 YES N/A
f-----
PB09-02140 PB09-02141 812712009 Soil PBRF K-40 pCilg 1.51E+01 1.89E+01 3.ooE+OO 10.0 1.25 YES N/A -
PB09-02160 PB09-02161 8/2612009 Soil PBRF K-40 pCi/g 1.43E+01 1.57E+01 2.90E+OO 10.0 1.10 YES N/A 1----- ----
--+
~ ---
-~
PB09-02160 PB09-02161 8/2612009 Soil PBRF Cs-137 pCilg 2.50E-01 3.60E-01 9.90E-02 5.0 1.44 YES N/A -
PB09-02180 PB09-02181 812712009 Soil PBRF K-40 pCi/g 1.69E+01 1.58E+01 3.50E+00 10.0 0.93 YES N/A PB09-02180 PB09-02181 8/2712009 Soil PBRF Cs-137 pCi/g 2.50E-01 2.90E-01 1.30E-01 3.8 1.16 YES N/A 1--------- -----
--~
PB09-022oo PB09-02201 812612009 Soil PBRF K-40 pCi/g 1.76E+01 1.41E+01 3.20E+OO 11.0 0.80 YES N/A f-------
PB09-02220 PB09-02221 8/2712009 Soil PBRF K-40 pCi/g 1.61E+01 1.69E+01 3.20E+00 10.0 1.05 YES N/A r
PB09-02220 PB09-02221 812712009 Soil PBRF Cs-137 pCi/g 2.90E-01 1.10E-01 1.13E-01 5.0 0.38 NO 004 PB09-02220 PB09-02221 812712009 Soil PBRF Cs-137 pCi/g 2.70E-01 3.00E-01 8.60E-02 6.0 1.11 YES N/A PB09-02240 PB09-02241 812712009 Soil PBRF K-40 pCi/g 1.54E+01 1.64E+01 3.00E+OO 10.0 1.06 YES N/A PB09-02240 PB09-02241 8/2712009 Soil PBRF Cs-137 pCi/g 3.15E-01 1.10E-01 1.11 E-01 6.0 0.35 NO 005 PB09-02240 PB09-02241 812712009 Soil PBRF Cs-137 pCi/g 2.70E-01 2.60E-01 8.ooE-02 7.0 0.96 YES N/A 18 INTRA-LABORATORY COMPARISON (REPLICATE) RESULTS Replicate c:
C SDR Gamma Log Sample 10 Original
.Q Q)
Number Number Number Acquisition Sample Analysis Nuclide Units Original Replicate 2 Sigma "5
Ratio E
SDR-Date Type Performed Result Result (5
~
(Original)
(Replicate)
Uncertainty III 09-By Q)
If e:::
PB09-02100 PB09-02101 812512009 Soil PBRF K-40 pCi/g 1.79E+01 1.33E+01 3.40E+00 11.0 0.74 YES N/A 1------ -----
PB09-02100 PB09-02101 812512009 Soil PBRF Cs-137 pCi/g 3.80E-01 2.60E-01 1.24E-01 6.0 0.68 YES N/A
-~
PB09-02120 PB09-02121 812612009 Soil PBRF K-40 pCilg 1.76E+01 1.41E+01 3.20E+00 11.0 0.80 YES N/A
f------
PB09-02140 PB09-02141 812712009 Soil PBRF K-40 pCilg 1.51E+01 1.89E+01 3.ooE+OO 10.0 1.25 YES N/A --
PB09-02160 PB09-02161 8/2612009 Soil PBRF K-40 pCi/g 1.43E+01 1.57E+01 2.90E+OO 10.0 1.10 YES N/A 1------ -----
--+-
~ ----
-~
PB09-02160 PB09-02161 8/2612009 Soil PBRF Cs-137 pCilg 2.50E-01 3.60E-01 9.90E-02 5.0 1.44 YES N/A --
PB09-02180 PB09-02181 812712009 Soil PBRF K-40 pCi/g 1.69E+01 1.58E+01 3.50E+00 10.0 0.93 YES N/A PB09-02180 PB09-02181 8/2712009 Soil PBRF Cs-137 pCi/g 2.50E-01 2.90E-01 1.30E-01 3.8 1.16 YES N/A 1---------- -------
--~
PB09-022oo PB09-02201 812612009 Soil PBRF K-40 pCi/g 1.76E+01 1.41E+01 3.20E+OO 11.0 0.80 YES N/A f--------
PB09-02220 PB09-02221 8/2712009 Soil PBRF K-40 pCi/g 1.61E+01 1.69E+01 3.20E+00 10.0 1.05 YES N/A r-PB09-02220 PB09-02221 812712009 Soil PBRF Cs-137 pCi/g 2.90E-01 1.10E-01 1.13E-01 5.0 0.38 NO 004 PB09-02220 PB09-02221 812712009 Soil PBRF Cs-137 pCi/g 2.70E-01 3.00E-01 8.60E-02 6.0 1.11 YES N/A PB09-02240 PB09-02241 812712009 Soil PBRF K-40 pCi/g 1.54E+01 1.64E+01 3.00E+OO 10.0 1.06 YES N/A PB09-02240 PB09-02241 8/2712009 Soil PBRF Cs-137 pCi/g 3.15E-01 1.10E-01 1.11 E-01 6.0 0.35 NO 005 PB09-02240 PB09-02241 812712009 Soil PBRF Cs-137 pCi/g 2.70E-01 2.60E-01 8.ooE-02 7.0 0.96 YES N/A 18
INTRA-LABORATORY COMPARISON (REPLICATE) RESULTS Gamma Log Number (Original)
Sample 10 Number (Replicate)
Acquisition Oate Sample Type Replicate Analysis Performed By Nuclide Units Original Result Replicate Result Original 2 Sigma Uncertainty c:
0
~
- l a III Q) 0:::
Ratio c:
Q)
E Q)
~
!i SOR Number SOR 09
- 11#
PB09-o225O PB09-o2261 812712009 Soil PBRF K-40 pCilg 1.80E+01 1.94E+01 3.50E+00 10.0 1.08 YES N/A PB09-02280 PB09-02281 812712009 Soil PBRF K-40 pCilg 1.4BE+01 1.63E+01
- 3. 1OE+Oo 10.0 1.10 YES N/A PB09-o2280 PB09-02281 812712009 Soil PBRF Cs-137 pCi/g 2.98E+00 3.ooE+00 3.6oE-D1 17.0 1.01 YES N/A N/A PB09-02300 PB09-02301 8128/2009 Soil PBRF K-40 pCi/g 1.08E+01 1.33E+01 2.5OE+00 8.0 1.23 YES PB09-02300 PB09-02301 812812009 Soil PBRF PBRF Cs-137 pCilg 2.80E-01 3.2DE-01 1.75E+01 1.10E-01 5.0 1.14 YES N/A PB09-02320 PB09-02321 812812009 Soil K-40 pCi/g 1.B4E+01 3.33E+00 11.0 0.95 YES N/A PB09-02320 PB09-02321 812812009 Soil PBRF Cs-137 pCilg 3.5OE-01 2.40E-01 1.20E-01 6.0 0.67 YES N/A PB09-o2340 PB09-o2341 PB09-02341 r-----
PB09-02361 813112009 Soil PBRF K-40 pCilg 1.49E+01 1.62E+01 3.14E+00 9.0 1.09 YES N/A PB09-02340 8/3112009 813112009 Soil Soil PBRF Cs-137 pCi/g 3.ooE-01 3.3OE-01 1.10E-01 5.0 1.10 YES N/A PB09-o2360 PBRF K-40 pCilg 1.69E+01 1.43E+01 2.20E+00 15.0 0.85 YES N/A PB09-o2360 PB09-o2361 8/3112009 Soil PBRF Cs-137 pCi/g 1.83E+01 1.90E+01 7.60E-01 48.0 1.04 YES N/A PB09-o2360 PB09-o2361 8/3112009 Soil PBRF Co-50 pCi/g 7.5OE-01 7.ooE-01 1.00E-01 15.0 10.0 0.92 YES N/A -----
PB09-o2380 PB09-02381 813112009 Soil PBRF K-40 pCi/g 1.5OE+01 1.5OE+01 3.30E+00 1.00 0.91 YES N/A PB09-02380 PB09-o2381 8/3112009 Soil PBRF Cs-137 pCilg 3.40E-01 3.10E-01 1.24E-01 5.0 YES N/A PB09-D2400 PB09-D2401 813112009 Soil PBRF K-40 pCilg 1.62E+01 1.74E+01 2.95E+00 11.0 1.07 YES N/A PB09-02420 PB09-02421 8/3112009 Soil PBRF K-40 pCi/g 1.40E+01 1.82E+01 3.00E+00 9.0 1.30 YES N/A PB09-D2420 PB09-02440 PB09-D2421 8/3112009 Soil PBRF Cs-137 pCi/g 3.40E-D1 3.40E-D1 1.2oE-01 6.0 1.00 YES YES N/A 1-----
N/A PB09-02441 91112009 Soil PBRF K-40 pCilg 1.72E+01 2.04E+01 3.30E+OO 10.0 1.19 PB09-o245O PB09-D2461 9/112009 Soil PBRF K-40 pCi/g 1.49E+01 1.58E+01 3.2oE+OO 9.0 1.06 YES N/A 19 INTRA-LABORATORY COMPARISON (REPLICATE) RESULTS Replicate c:
SOR c:
Gamma Log Sample 10 Original 0
Q)
Number Acquisition Sample Analysis Original Replicate
~
E Number Number Nuclide Units 2 Sigma
- l Ratio SOR-a Q)
(Original)
(Replicate)
Oate Type Performed Result Result Uncertainty III
~
09-By Q)
!i 0:::
- 11#
PB09-o225O PB09-o2261 712009 Soil PBRF K-40 pCilg 1.80E+01 1.94E+01 3.50E+00 10.0 1.08 YES N/A
~~~-
PB09-02280 PB09-02281 712009 Soil PBRF K-40 pCilg 1.48E+01 1.63E+01
- 3. 1 OE+Oo 10.0 1.10 YES N/A PB09-o2280 PB09-02281 812712009 Soil PBRF Cs-137 pCi/g 98E+00 3.ooE+00 3.6oE-D1 17.0 1.01 YES N/A
~----~~~-
PB09-02300 PB09-02301 8128/2009 Soil PBRF K-40 pCi/g 1.08E+01 1.33E+01 2.5OE+00 8.0 1.23 YES N/A PB09-02300 PB09-02301 812812009 Soil PBRF Cs-137 pCilg 2.80E-01 3.2DE-01 1.10E-01 5.0 1.14 YES N/A
--~
~----
PB09-02320 PB09-02321 812812009 Soil PBRF K-40 pCi/g 1.84E+0~ 1.75E+01 3.33E+00 11.0 0.95 YES N/A
-- r-~~
~----~
I PB09-02320 PB09-02321 812812009 Soil PBRF Cs-137 pCilg 3.5OE-01 2.40E-01 1.20E-01 6.0 0.67 YES N/A PB09-o2340 PB09-o2341 813112009 Soil PBRF K-40 pCilg 1.49E+01 1.62E+01 3.14E+00 9.0 1.09 YES N/A PB09-02340 PB09-02341 8/3112009 Soil PBRF Cs-137 pCi/g 3.ooE-01 3.3OE-01 1.10E-01 5.0 1.10 YES N/A
-~~~
~-
PB09-o2360 PB09-02361 813112009 Soil PBRF K-40 pCilg 1.69E+01 1.43E+01 2.20E+00 15.0 0.85 YES N/A
-~~
PB09-o2360 PB09-o2361 8/3112009 Soil PBRF Cs-137 pCi/g 1.83E+01 1.90E+01 7.60E-01 48.0 1.04 Y
N/A
~-~
PB09-o2360 PB09-o2361 8/3112009 Soil PBRF Co-50 pCi/g 7.5OE-01 7.ooE-01 1.00E-01 15.0 0.92 YES N/A PB09-o2380 PB09-02381 813112009 Soil PBRF K-40 pCi/g 1.5OE+01 1.5OE+01 3.30E+00 10.0 1.00 YES N/A
~-~
PB09-02380 PB09-o2381 8/3112009 Soil PBRF Cs-137 pCilg 3.40E-01 3.10E-01 1.24E-01 5.0 0.91 YES N/A PB09-D2400 PB09-D2401 813112009 Soil PBRF K-40 pCilg 1.62E+01 1.74E+01 2.95E+00 11.0 1.07 YES N/A PB09-02420 PB09-02421 8/3112009 Soil PBRF K-40 pCi/g 1.40E+01 1.82E+01 3.00E+00 9.0 1.30 YES N/A
~~-
PB09-D2420 PB09-D2421 8/3112009 Soil PBRF Cs-137 pCi/g 3.40E-D1 3.40E-D1 1.2oE-01 6.0 1.00 YES N/A c--~~
~---~
- --~-
PB09-02440 PB09-02441 91112009 Soil PBRF K-40 pCilg 1.72E+01 2.04E+01 3.30E+OO 10.0 1.19 YES N/A PB09-o245O PB09-D2461 9/112009 Soil PBRF K-40 pCi/g 1.49E+01 1.58E+01 3.2oE+OO 9.0 1.06 YES N/A 19
INTRA-LABORATORY COMPARISON (REPLICATE) RESULTS Replicate c:
SOR c:
Gamma Log Sample 10 Original 0
CD Number Acquisition Sample Analysis Original Replicate
- l E
Number Number Nuclide Units 2 Sigma
- I Ratio SOR-Date Type Performed Result Result (5
CD (Original)
(Replicate)
Uncertainty II)
CD 09 By CD
~
a::
PB09-02460 PB09-02461 9/1/2009 Soil PBRF Cs-137 pCi/g 2.70E-01 2.80E-01 1.10E-01 5.0 1.04 YES N/A PB09-02480 PB09-02481 9/112009 Soil PBRF K-40 pCilg 1.84E+01 1.69E+01 3.40E+OO 11.0 0.92 YES N/A PB09-02480 PB09-02481 9/112009 Soil PBRF Cs-137 pCi/g 4.30E-01 3.20E-01 1.35E-01 6.0 0.74 YES N/A PB09-02500 PB09-02501 91212009 Soil PBRF K-40 pCi/g 1.69E+01 1.91E+01 3.23E+OO 10.0 1.13 YES N/A PB09-02500 PB09-02501 91212009 Soil PBRF Cs-137 pCi/g 1.90E-01 1.10E-01 8.80E-02 4.0 0.58 YES N/A 1------------------
PB09-02520 PB09-02521 9/212009 Soil PBRF K-40 pCi/g 1.87E+01 1.81E+01 3.50E+00 11.0 0.97 YES N/A PB09-02520 PB09-02521 91212009 Soil PBRF Cs-137 pCi/g 1.90E-01 2.80E-01 9.00E-02 4.0 1.47 YES N/A PB09-02540 PB09-02541 9/212009 Soil PBRF K-40 pCi/g 2.09E+01 1.89E+01 3.70E+OO 11.0 0.90 YES N/A PB09-02560 PB09-02561 91312009 Soil PBRF K-40 pCi/g 1.79E+01 1.90E+01 3.20E+OO 11.0 1.06 YES N/A
1-----
PB09-02580 PB09-02581 9/312009 Soil PBRF K-40 pCi/g 2.00E+01 1.72E+01 3.70E+OO 11.0 0.86 YES N/A PB09-02580 PB09-02581 91312009 Soil PBRF Cs-137 pCi/g 2.20E-01 4.00E-01 9.70E-02 5.0 1.82 YES N/A PB09-02600 PB09-02601 9/312009 Soil PBRF K-40 pCi/g 1.49E+01 2.00E+01 3.2DE+OO 9.0 1.34 YES N/A PB09-02600 PB09-02601 9/312009 Soil PBRF Cs-137 pCi/g 3.1OE-01 3.30E-01 1.20E-01 5.0 1.06 YES N/A PB09-02620 PB09-02621 9/812009 Soil PBRF K-40 pCi/g 1.73E+01 1.50E+01 3.20E+OO 11.0 0.87 YES N/A PB09-02620 PB09-02621 9/812009 Soil PBRF Cs-137 pCi/g 3.70E-01 3.20E-01 1.20E-01 6.0 0.86 YES N/A PB09-02640 PB09-02641 9/812009 Soil PBRF K-40 pCi/g 1.72E+01 1.84E+01 3.00E+OO 11.0 1.07 YES N/A PB09-02640 PB09-02641 9/812009 Soil PBRF Cs-137 pCi/g 2.60E-01 1.50E-01 1.10E-01 5.0 0.58 YES NlA PB09-02660 PB09-02661 9/912009 Soil PBRF K-40 pCi/g 1.86E+01 2.45E+01 3.90E+00 10.0 1.32 YES N/A
~
20 INTRA-LABORATORY COMPARISON (REPLICATE) RESULTS Replicate c:
SOR c:
Gamma Log Sample 10 Original 0
CD Number Acquisition Sample Analysis Original Replicate
- l E
Number Number Nuclide Units 2 Sigma
- I Ratio SOR-Date Type Performed Result Result (5
CD (Original)
(Replicate)
Uncertainty II)
CD 09-By CD
~
a::
PB09-02460 PB09-02461 9/1/2009 Soil PBRF Cs-137 pCi/g 2.70E-01 2.80E-01 1.10E-01 5.0 1.04 YES N/A PB09-02480 PB09-02481 9/112009 Soil PBRF K-40 pCilg 1.84E+01 1.69E+01 3.40E+OO 11.0 0.92 YES N/A PB09-02480 PB09-02481 9/112009 Soil PBRF Cs-137 pCi/g 4.30E-01 3.20E-01 1.35E-01 6.0 0.74 YES N/A
~----
PB09-02500 PB09-02501 91212009 Soil PBRF K-40 pCi/g 1.69E+01 1.91E+01 3.23E+OO 10.0 1.13 YES N/A PB09-02500 PB09-02501 91212009 Soil PBRF Cs-137 pCi/g I 1.90E-01 1.10E-01 8.80E-02 4.0 0.58 YES N/AJI
~------------
PB09-02520 PB09-02521 9/212009 Soil PBRF K-40 pCi/g 1.87E+01 1.81E+01 3.50E+00 11.0 0.97 YES N/A 02520 PB09-02521 91212 Soil PBRF Cs-137 pCi/g 1.90E-01 2.80E-01 9.00E-02 4.0 1.47 YES N/A
.--. 1---
PB09-02540 PB09-02541 9/212009 Soil PBRF K-40 pCi/g 2.09E+01 1.89E+01 3.70E+OO 11.0 0.90 YES N/A PB09-02560 PB09-02561 91312009 Soil PBRF K-40 pCi/g 1.79E+01 1.90E+01 3.20E+OO 11.0 1.06 ~
N/A
~ 1------
PB09-02580 PB09-02581 9/312009 Soil PBRF K-40 pCi/g 2.00E+01 1.72E+01 3.70E+OO 11.0 0.86 S
N/A I
PB09-02580 PB09-02581 91312009 Soil PBRF Cs-137 pCi/g 2.20E-01 4.00E-01 9.70E-02 5.0 1.82 YES N/A PB09-02600 PB09-02601 9/312009 Soil PBRF K-40 pCi/g 1.49E+01 2.00E+01 3.2DE+OO 9.0 1.34 YES N/A f-------
.-~
PB09-02600 I
PB09-02601 9/312009 Soil PBRF Cs-137 pCi/g
- 3. 1 OE-01 3.30E-01 1.20E-01 5.0 1.06 YES N/A I
PB09-02620 PB09-02621 9/812009 Soil PBRF K-40 pCi/g 1.73E+01 1.50E+01 3.20E+OO 11.0 0.87 YES N/A 1------------
PB09-02620 PB09-02621 I
9/812009 Soil PBRF Cs-137 pCi/g 3.70E-01 3.20E-01 1.20E-01 6.0 0.86 _ YES N/A 1.72E~;
PB09-02640 PB09-02641 9/812009 Soil PBRF K-40 pCi I 1.84E+01 3.00E+OO 11.0 7
YES N/A PB09-02640 PB09-02641 9/812009 Soil PBRF Cs-137 pCi/g 2.60E-01 1.50E-01 1.10E-01 5.0 0.58 YES NlA 1.~~JYES PB09-02660 PB09-02661 9/912009 Soil PBRF K-40 pCi/g 1.86E+01 2.45E+01 3.90E+00 10.0 N/A 20
INTRA-LABORATORY COMPARISON (REPLICATE) RESULTS Replicate c::
SDR c::
Gamma Log Sample ID Original
.Q CJ)
Number Acquisition Sample Analysis Original Replicate E
Number Number Nuclide Units 2 Sigma
- l Ratio SDR Date Type Performed Result Result (5
~
(Original)
(Replicate)
Uncertainty (f) 09 By CJ)
- if 0:::
PB09-02660 PB09-02661 9/9/2009 Soil PBRF Cs-137 pCi/g 5.70E-01 7.50E-01 1.70E-01 7.0 1.32 YES N/A PB09-02680 PB09-02681 9/9/2009 Soil PBRF K-40 pCi/g 1.34E+01 1.29E+01 3.10E+00 9.0 0.96 YES N/A PB09-02680 PB09-02681 9/9/2009 Soil PBRF Cs-137 pCi/g 7.ooE-01 6.ooE-01 1.80E-01 8.0 0.86 YES N/A PB09-02700 PB09-02701 9/9/2009 Soil PBRF K-40 pCilg 1.35E+01 1.53E+01 2.90E+00 9.0 1.13 YES N/A
-~
PB09-02700 PB09-02701 9/9/2009 Soil PBRF Cs-137 pCi/g 2.80E-01 2.90E-01 1.30E-01 4.0 1.04 YES N/A PB09-02720 PB09-02721 9/10/2009 Soil PBRF K-40 pCi/g 1.76E+01 2.03E+01 3.50E+00 10.0 1.15 YES N/A PB09-02720 PB09-02721 9/10/2009 Soil PBRF Cs-137 pCilg 3.50E-01 3.20E-01 1.60E-01 4.0 0.91 YES N/A
~----
PB09-02740 PB09-02741 9110/2009 Soil PBRF K-40 pCilg 1.59E+01 1.35E+01 3.30E+00 10.0 0.85 YES N/A PB09-02740 PB09-02741 9/10/2009 Soil PBRF Cs-137 pCilg 6.20E-01 5.90E-01 1.70E-01 7.0 0.95 YES N/A PB09-02760 PB09-02761 9110/2009 Soif PBRF K-40 pCi/g 1.62E+01 1.30E+01 3.30E+00 10.0 0.80 YES N/A PB09-02760 PB09-02761 9/10/2009 Soif PBRF Cs-137 pCi/g 4.20E-01 3.50E-01 1.30E-01 6.0 0.83 YES N/A PB09-02780 PB09-02781 9/11/2009 Soil PBRF K-40 pCi/g 1.73E+01 1.99E+01 3.20E+00 11.0 1.15 YES N/A PB09-02800 PB09-02801 9111/2009 Soil PBRF K-40 pCi/g 1.48E+01 1.51E+01 2.90E+00 10.0 1.02 YES N/A PB09-02800 PB09-02801 9111/2009 Soil PBRF Cs-137 pCi/g 3.20E-01 4.40E-01 1.11E+00 0.6 1.38 YES N/A PB09-02820 PB09-02821 9/11/2009 Soil PBRF K-40 pCi/g 1.79E+01 1.68E+01 3.50E+00 10.0 0.94 YES N/A PB09-02820 PB09-02821 9/11/2009 Soil PBRF Cs-137 pCi/g 4.50E-01 2.80E-01 1.40E-01 6.0 0.62 YES N/A PB09-02840 PB09-02841 9111/2009 Soil PBRF K-40 pCi/g 1.49E+01 1.47E+01 3.10E+00 10.0 0.99 YES N/A 21 I
INTRA-LABORATORY COMPARISON (REPLICATE) RESULTS Replicate c::
SDR c::
Gamma Log Sample ID Original
.Q CJ)
Number Acquisition Sample Analysis Original Replicate E
Number Number Nuclide Units 2 Sigma
- l Ratio SDR-Date Type Performed Result Result (5
~
(Original)
(Replicate)
Uncertainty (f) 09-By CJ)
- if 0:::
PB09-02660 PB09-02661 9/9/2009 Soil PBRF Cs-137 pCi/g 5.70E-01 7.50E-01 1.70E-01 7.0 1.32 YES N/A PB09-02680 PB09-02681 9/9/2009 Soil PBRF K-40 pCi/g 1.34E+01 1.29E+01 3.10E+00 9.0 0.96 YES N/A PB09-02680 PB09-02681 9/9/2009 Soil PBRF Cs-137 pCi/g 7.ooE-01 6.ooE-01 1.80E-01 8.0 0.86 YES N/A PB09-02700 PB09-02701 9/9/2009 Soil PBRF K-40 pCilg 1.35E+01 1.53E+01 2.90E+00 9.0 1.13 YES N/A I--------
-~
PB09-02700 PB09-02701 9/9/2009 Soil PBRF Cs-137 pCi/g 2.80E-01 2.90E-01 1.30E-01 4.0 1.04 YES N/A PB09-02720 PB09-02721 9/10/2009 Soil PBRF K-40 pCi/g 1.76E+01 2.03E+01 3.50E+00 10.0 1.15 YES N/A PB09-02720 PB09-02721 9/10/2009 Soil PBRF Cs-137 pCilg 3.50E-01 3.20E-01 1.60E-01 4.0 0.91 YES N/A PB09-02740 PB09-02741 9110/2009 Soil PBRF K-40 pCilg 1.59E+01 1.35E+01 3.30E+00 10.0 0.85 YES N/A PB09-02740 PB09-02741 9/10/2009 Soil PBRF Cs-137 pCilg 6.20E-01 5.90E-01 1.70E-01 7.0 0.95 YES N/A c----
PB09-02760 PB09-02761 9110/2009 Soif PBRF K-40 pCi/g 1.62E+01 1.30E+01 3.30E+00 10.0 0.80 YES N/A PB09-02760 PB09-02761 9/10/2009 Soif PBRF Cs-137 pCi/g 4.20E-01 3.50E-01 1.30E-01 6.0 0.83 YES N/A PB09-02780 PB09-02781 9/11/2009 Soil PBRF K-40 pCi/g 1.73E+01 1.99E+01 3.20E+00 11.0 1.15 YES N/A PB09-02800 PB09-02801 9111/2009 Soil PBRF K-40 pCi/g 1.48E+01 1.51E+01 2.90E+00 10.0 1.02 YES N/A PB09-02800 PB09-02801 9111/2009 Soil PBRF Cs-137 pCi/g 3.20E-01 4.40E-01 1.11E+00 0.6 1.38 YES N/A f---
PB09-02820 PB09-02821 9/11/2009 Soil PBRF K-40 pCi/g 1.79E+01 1.68E+01 3.50E+00 10.0 0.94 YES N/A
--- 1------
PB09-02820 PB09-02821 9/11/2009 Soil PBRF Cs-137 pCi/g 4.50E-01 2.80E-01 1.40E-01 6.0 0.62 YES N/A PB09-02840 PB09-02841 9111/2009 Soil PBRF K-40 pCi/g 1.49E+01 1.47E+01 3.10E+00 10.0 0.99 YES N/A
~
21
I INTRA-LABORATORY COMPARISON (REPLICATE) RESULTS Gamma Log Number (Original)
PB09-02840 PB09-02860 PB09-02860 PB09-02880 PB09-02880 PB09-02900 PB09-02900 PB09-02920 PB09-02920 PB09-02940 PB09-02940 PB09-02960 PB09-02980 PB09-02980 PB09-03OO0 PB09-03000 PB09-03020 PB09-03020 PB09-03040 Sample ID Number (Replicate)
PB09-02841 PB09-02861 PB09-02861 PB09-02881 PB09-02881 PB09-02901 PB09-02901 PB09-02921 PB09-02921 PB09-02941 PB09-02941 PB09-02961 PB09-02981 PB09-02981 PB09-03001 PB09-03OO1 PB09-03021 PB09-03021 PB09-03041 Acquisition Date 9/1112009 911512009 9/1512009 9/1512009 9/1512009 9/1512009 911512009 9/1512009 9/1512009 9/1612009 9/1612009 9/1612009 9/1612009 911612009 9/1612009 9/1612009 9/1712009 9/1712009 911712009 Sample Type Soil Soil Soil Soil Soil Soil Soil Soil Soil Soil Soil Soil Soil Soil Soil Soil Soil Soil Soil Replicate Analysis Performed By PBRF PBRF PBRF PBRF PBRF PBRF PBRF PBRF PBRF PBRF PBRF PBRF PBRF 1---
PBRF PBRF PBRF PBRF PBRF PBRF Nuclide Cs-137 K-40 Cs-137 K-40 Cs-137 K-40 Cs-137 K-40 Cs-137 K-40 Cs-137 K-40 K-40 Cs-137 K-40 Cs-137 K-40 Cs-137 K-40 Units pCi/g pCi/g pCilg pCilg pCi/g pCilg pCi/g pCilg pCi/g pCi/g pCi/g
---~
pCilg pCilg pCi/g pCilg pCi/g pCi/g pCi/g pCilg Original Result 4.90E-01 1.38E+01 3.50E-01 1.68E+01 3.40E-01 1.38E+01 4.00E-01 1.97E+01 6.70E-01 1.61E+01 4.80E-01
- 2. 1OE+01 1.53E+01 4.10E-01 1.00E+01 5.10E-01 f---------
1.93E+01 1.ooE+00 1.65E+01 Replicate Result 4.00E-01 1.61E+01 4.80E-01 1.37E+01 4.00E-01 1.34E+01 3.70E-01 1.90E+01 6.30E-01 1.48E+01 6.90E-01 2.20E+01 1.00E+01 3.10E-01 2.05E+01 3.70E-01 1.63E+01 6.60E-01 1.36E+01 Original 2 Sigma Uncertainty 1.40E-01 3.10E+00 1.23E-01 3.20E+00 1.10E-01 3.00E+00 1.30E-01 3.40E+00 1.60E-01 2.30E+00 1.10E-01 3.60E+00 3.30E+00 1.30E-01 3.50E+00 1.60E-01 3.70E+00 2.10E-01 3.62E+00
£::
0:;::;
- J a t/)
CD 0::
7.0 9.0 6.0 11.0 6.0 9.0 6.0 12.0 8.0 14.0 9.0 12.0 9.0 6.0
--~
9.0 6.0 10.0 10.0 9.0 Ratio 0.82 1.17 1.37 0.82 C---
1.18 0.97 1-0.93 0.96 0.94 0.92 1.44 1.05 f---------
1.08 0.76 1.23 0.73 0.84 0.00 0.82
.oJ
£::
CD E CD CD...
C)
YES YES YES YES YES YES YES YES YES YES YES YES YES YES YES YES YES YES YES SDR Number SDR 09 N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A NIA N/A N/A N/A N/A 22 INTRA-LABORATORY COMPARISON (REPLICATE) RESULTS Replicate
£::
.oJ SDR
£::
Gamma Log Sample ID Original 0
CD Number Acquisition Sample Analysis Original Replicate E
Number Number Nuclide Units 2 Sigma
- J Ratio SDR-a CD Date Type Performed Result Result CD (Original)
(Replicate)
Uncertainty t/)
09-By CD C) 0::
PB09-02840 PB09-02841 9/1112009 Soil PBRF Cs-137 I pCi/g 4.90E-01 4.00E-01 1.40E-01 7.0 0.82 YES N/A PB09-02860 PB09-02861 911512009 Soil PBRF K-40 pCi/g 1.38E+01 1.61E+01 3.10E+00 9.0 1.17 YES N/A PB09-02860 PB09-02861 9/1512009 Soil PBRF Cs-137 pCilg 3.50E-01 4.80E-01 1.23E-01 6.0 1.37 YES N/A PB09-02880 PB09-02881 9/1512009 Soil PBRF K-40 pCilg 1.68E+01 1.37E+01 3.20E+00 11.0 0.82 YES N/A L---- ___
PB09-02880 PB09-02881 9/1512009 Soil PBRF Cs-137 pCi/g 3.40E-01 4.00E-01 1.10E-01 6.0 1.18 YES N/A PB09-02900 PB09-02901 9/1512009 Soil PBRF K-40 pCilg 1.38E+01 1.34E+01 3.00E+00 9.0 0.97 YES N/A PB09-02900 PB09-02901 911512009 Soil PBRF Cs-137 pCi/g 4.00E-01 3.70E-01 1.30E-01 6.0 0.93 YES N/A PB09-02920 PB09-02921 9/1512009 Soil PBRF K-40 pCilg 1.97E+01 1.90E+01 3.40E+00 12.0 0.96 YES N/A
- I----
PB09-02920 PB09-02921 9/1512009 Soil PBRF Cs-137 pCi/g 6.70E-01 6.30E-01 1.60E-01 8.0 0.94 YES N/A
~--
PB09-02940 PB09-02941 9/1612009 Soil PBRF K-40 pCi/g 1.61E+01 1.48E+01 2.30E+00 14.0 0.92 YES N/A PB09-02940 PB09-02941 9/1612009 Soil PBRF Cs-137 pCi/g 4.80E-01 6.90E-01 1.10E-01 9.0 1.44 YES N/A PB09-02960 PB09-02961 9/1612009 Soil PBRF K-40 pCilg
- 2. 1 OE+01 2.20E+01 3.60E+00 12.0 1.05 YES N/A PB09-02980 PB09-02981 9/1612009 Soil PBRF K-40 pCilg 1.53E+01 1.00E+01 3.30E+00 9.0 1.08 YES N/A
~--
PB09-02980 PB09-02981 911612009 Soil PBRF Cs-137 pCi/g 4.10E-01 3.10E-01 1.30E-01 6.0 0.76 YES N/A I---
PB09-03OO0 PB09-03001 9/1612009 Soil PBRF K-40 pCilg 1.00E+01 2.05E+01 3.50E+00 9.0 1.23 YES NIA PB09-03000 PB09-03OO1 9/1612009 Soil PBRF Cs-137 pCi/g 5.10E-01 3.70E-01 1.60E-01 6.0 0.73 YES N/A PB09-03020 PB09-03021 9/1712009 Soil PBRF K-40 pCi/g 1.93E+01 1.63E+01 3.70E+00 10.0 0.84 YES N/A PB09-03020 PB09-03021 9/1712009 Soil PBRF Cs-137 pCi/g 1.ooE+00 6.60E-01 2.10E-01 10.0 0.00 YES N/A PB09-03040 PB09-03041 911712009 Soil PBRF K-40 ilg 1.65E+01 1.36E+01 I 3.62E+00 9.0 0.82 YES N/A 22
INTRA-LABORATORY COMPARISON (REPLICATE) RESULTS Replicate r::::
SDR r::::
Gamma Log Sample ID Original
- 8 Q)
Number Number Number Acquisition Sample Analysis Nuclide Units Original Replicate 2 Sigma
- l Ratio E
SDR-Date Type Performed Result Result (5
Q)
(Replicate)
Uncertainty II)
Q) 09 (Original)
By (J)
- f 0::
PB09-03040 PB09-03041 9/1712009 Soil PBRF Cs-137 pCi/g 3.80E-01 2.99E-01 1.40E-01 5.0 0.79 YES N/A PB09-03060 PB09-03061 9/1812009 Soil PBRF K-40 pCi/g 1.81E+01 1.55E+01 3.50E+00 10.0 0.86 YES N/A PB09-03060 PB09-03061 9/1812009 Soil PBRF Cs-137 pCi/g 4.40E-01 4.50E-01 1.40E-01 6.0 1.02 YES N/A PB09-03080 PB09-03081 9/1812009 Soil PBRF K-40 pCi/g 2.19E+01 2.63E+01 3.70E+00 12.0 1.20 YES N/A 1--------
PB09-031 00 PB09-03101 9/1812009 Soil PBRF K-40 pCi/g 1.37E+01 1.50E+01 3.11E+00 9.0 1.09 YES N/A PB09-03100 PB09-03101 9/1812009 Soil PBRF Cs-137 pCi/g 3.90E-01 3.40E-01 1.60E-01 5.0 0.87 YES N/A PB09-03120 PB09-03121 9/1812009 Soil PBRF K-40 pCi/g 1.54E+01 1.63E+01 2.30E+00 13.0 1.06 YES N/A PB09-03120 PB09-03121 9/1812009 Soil PBRF Cs-137 pCi/g 2.90E-01 4.ooE-01 9.00E-02 6.0 1.38 YES N/A
~--
PB09-03140 PB09-03141 912112009 Soil PBRF K-40 pCilg 1.10E+01 1.40E+01 2.60E+00 8.0 1.27 YES N/A PB09-03160 PB09-03161 912112009 Soil PBRF K-40 pCi/g 1.84E+01 1.51E+01 2.60E+00 14.0 0.82 YES N/A PB09-03160 PB09-03161 9/2112009 Soil PBRF Cs-137 pCilg 5.10E-01 4.30E-01 1.10E-01 9.0 0.84 YES N/A PB09-03180 PB09-03181 912112009 Soil PBRF K-40 pCilg 1.58E+01 1.80E+01 3.43E+00 9.0 1.14 YES N/A PBQ9-03180 PB09-03181 912112009 Soil PBRF Cs-137 pCi/g 3.40E-01 5.40E-01 1.30E-01 5.0 1.59 YES N/A PB09-03200 PB09-03201 912112009 Soil PBRF K-40 pCilg 1.71E+01 1.48E+01 3.30E+00 10.0 0.87 YES N/A PB09-03200 PB09-03201 912112009 Soil PBRF Cs-137 pCilg 1.60E+00 1.70E+00 2.60E-01 12.0 1.06 YES N/A PB09-03220 PB09-03221 9/2212009 Soil PBRF K-40 pCi/g 1.67E+01 1.54E+01 3.30E+00 10.0 0.92 YES N/A PB09-03220 PB09-03221 912212009 Soil PBRF Cs-137 pCi/g 3.40E-01 3.50E-01 1.20E-01 6.0 1.03 YES N/A PB09-03240 PB09-03241 912212009 Soil PBRF K-40 pCilg 1.34E+01 1.51E+01 3.10E+00 9.0 1.13 YES N/A 23 INTRA-LABORATORY COMPARISON (REPLICATE) RESULTS Replicate r::::
SDR r::::
Gamma Log Sample ID Original
- 8 Q)
Number Number Number Acquisition Sample Analysis Nuclide Units Original Replicate 2 Sigma
- l Ratio E
SDR-Date Type Performed Result Result (5
Q)
(Replicate)
Uncertainty II)
Q) 09-(Original)
By (J)
- f 0::
PB09-03040 PB09-03041 9/1712009 Soil PBRF Cs-137 pCi/g 3.80E-01 2.99E-01 1.40E-01 5.0 0.79 YES N/A PB09-03060 PB09-03061 9/1812009 Soil PBRF K-40 pCi/g 1.81E+01 1.55E+01 3.50E+00 10.0 0.86 YES N/A PB09-03060 PB09-03061 9/1812009 Soil PBRF Cs-137 pCi/g 4.40E-01 4.50E-01 1.40E-01 6.0 1.02 YES N/A
-- f---------------
PB09-03080 PB09-03081 9/1812009 Soil PBRF K-40 pCi/g 2.19E+01 2.63E+01 3.70E+00 12.0 1.20 YES N/A PB09-031 00 PB09-03101 9/1812009 Soil PBRF K-40 pCi/g 1.37E+01 1.50E+01 3.11E+00 9.0 1.09 YES N/A PB09-03100 PB09-03101 9/1812009 Soil PBRF Cs-137 pCi/g 3.90E-01 3.40E-01 1.60E-01 5.0 0.87 YES N/A PB09-03120 PB09-03121 9/1812009 Soil PBRF K-40 pCi/g 1.54E+01
! 1.63E+01 2.30E+00 13.0 1.06 YES N/A f---------
--~--
PB09-03120 PB09-03121 9/1812009 Soil PBRF Cs-137 pCi/g 2.90E-01 4.ooE-01 9.00E-02 6.0 1.38 YES N/A f----- -------- ---
1----
PB09-03140 PB09-03141 912112009 Soil PBRF K-40 pCilg 1.10E+01 1.40E+01 2.60E+00 8.0 1.27 YES N/A
--f-----
PB09-03160 PB09-03161 912112009 Soil PBRF K-40 pCi/g 1.84E+01 1.51E+01 2.60E+00 14.0 0.82 YES N/A PB09-03160 PB09-03161 9/2112009 Soil PBRF Cs-137 pCilg 5.10E-01 4.30E-01 1.10E-01 9.0 0.84 YES N/A PB09-03180 PB09-03181 912112009 Soil PBRF K-40 pCilg 1.58E+01 1.80E+01 3.43E+00 9.0 1.14 YES N/A PBQ9-03180 PB09-03181 912112009 Soil PBRF Cs-137 pCi/g 3.40E-01 5.40E-01 1.30E-01 5.0 1.59 YES N/A PB09-03200 PB09-03201 912112009 Soil PBRF K-40 pCilg 1.71E+01 1.48E+01 3.30E+00 10.0 0.87 YES N/A PB09-03200 PB09-03201 912112009 Soil PBRF Cs-137 pCilg 1.60E+00 1.70E+00 2.60E-01 12.0 1.06 YES N/A PB09-03220 PB09-03221 9/2212009 Soil PBRF K-40 pCi/g 1.67E+01 1.54E+01 3.30E+00 10.0 0.92 YES N/A PB09-03220 PB09-03221 912212009 Soil PBRF Cs-137 pCi/g 3.40E-01 3.50E-01 1.20E-01 6.0 1.03 YES N/A f---------
PB09-03240 PB09-03241 912212009 Soil PBRF K-40 pCilg 1.34E+01 1.51E+01 3.10E+00 9.0 1.13 YES N/A 23
INTRA-LABORATORY COMPARISON (REPLICATE) RESULTS Replicate r:::::
'E SDR Gamma Log Sample ID Original 0
Ql Number Acquisition Sample Analysis Original Replicate
- .;::l E
Number Number Nuclide Units 2 Sigma
- I Ratio SDR-Date Type Performed Result Result
~
~
(Original)
(Replicate)
By Uncertainty Ql Jf 09 a::
PB09-03240 PB09-03241 9/2212009 Soil PBRF Cs-137 pCi/g 3.10E-01 4.50E-01 1.20E-01 5.0 1.45 YES N/A PB09-03260 PB09-03261 912212009 Soil PBRF K-40 pCi/g 1.59E+01 1.74E+01 2.20E+00 14.0 1.09 YES NIA PB09-03260 PB09-03261 912212009 Soil PBRF Cs-137 pCi/g 3.70E-01 2.60E-01 9.50E-02 8.0 0.70 YES N/A PB09-03280 PB09-03281 912312009 Soil PBRF K-40 pCi/g 1.73E+01 1.63E+01 3.34E+00 10.0 0.94 YES NIA PB09-03280 PB09-03281 9/2312009 Soil PBRF Cs-137 pCilg 4.20E-01 3.80E-01 1.60E-01 5.0 0.90 YES N/A
--~-
PB09-033oo PB09-03301 9/2312009 Soil PBRF K-40 pCilg 1.45E+01 1.79E+01 3.15E+00 9.0 1.23 YES NIA PB09-03300 PB09-03301 912312009 Soil PBRF Cs-137 pCi/g 4.60E-01 4.40E-01 1.50E-01 6.0 0.96 YES NIA PB09-03320 PB09-03321 912312009 Soil PBRF K-40 pCi/g 1.59E+01 1.43E+01 3.40E+00 9.0 0.90 YES N/A PB09-03320 PB09-03321 9/2312009 Soil PBRF Cs-137 pCilg 4.10E-01 2.70E-01 1.40E-01 6.0 0.66 YES NIA PB09-03340 PB09-03341 912312009 Soil PBRF K-40 pCi/g 2.13E+01 1.98E+01 4.ooE+00 11.0 0.93 YES N/A PB09-03360 PB09-03361 912412009 Soil PBRF K-40 pCi/g 1.72E+01 1.66E+01 3.60E+00 10.0 0.97 YES NIA PB09-03360 PB09-03361 912412009 Soil PBRF Cs-137 pCi/g 4.20E-01 4.20E-01 1.20E-01 7.0 1.00 YES N/A PB09-03380 PB09-03381 912412009 Soil PBRF K-40 pCi/g 1.50E+01 1.65E+01 2.30E+00 13.0 1.10 YES NIA
---~ ---
PB09-03380 PB09-03381 912412009 Soil PBRF Cs-137 pCi/g 3.30E-01 3.10E-01 9.ooE-02 7.0 0.94 YES NIA PB09-03400 PB09-03401 912412009 Soil PBRF K-40 pCilg 1.67E+01 1.66E+01 3.40E+00 10.0 0.99 YES N/A PB09-034oo PB09-03401 912412009 Soil PBRF Cs-137 pCilg 4.60E-01 4.30E-01 1.40E-01 7.0 0.93 YES NIA PB09-03420 PB09-03241 912412009 Soil PBRF K-40 pCi/g 1.91E+01 1.60E+01 3.20E+00 12.0 0.84 YES NIA f---
PB09-03440 PB09-03441 912512009 Soil PBRF K-40 pCi/g 2.04E+01 1.90E+01 3.80E+00 11.0 0.93 YES NIA 24 INTRA-LABORATORY COMPARISON (REPLICATE) RESULTS Replicate r:::::
'E SDR Gamma Log Sample ID Original 0
Ql Number Acquisition Sample Analysis Original Replicate
- .;::l E
Number Number Nuclide Units 2 Sigma
- I Ratio SDR-Date Type Performed Result Result
~
~
(Original)
(Replicate)
By Uncertainty Ql Jf 09-a::
PB09-03240 PB09-03241 9/2212009 Soil PBRF Cs-137 pCi/g 3.10E-01 4.50E-01 1.20E-01 5.0 1.45 YES N/A PB09-03260 PB09-03261 912212009 Soil PBRF K-40 pCi/g 1.59E+01 1.74E+01 2.20E+00 14.0 1.09 YES NIA PB09-03260 PB09-03261 912212009 Soil PBRF Cs-137 pC 3.70E-01 I 2.60E-01 9.50E-02 8.0 0.70 YES N/A PB09-03280 PB09-03281 912312009 Soil PBRF K-40 pCi/g 1.73E+01 1.63E+01 3.34E+00 10.0 0.94 YES NIA PB09-03280 PB09-03281 9/2312009 Soil PBRF Cs-137 pCilg 4.20E-01 3.80E-01 1.60E-01 5.0 0.90 YES N/A
--f----
PB09-033oo PB09-03301 9/2312009 Soil PBRF K-40 pCilg 1.45E+01 1.79E+01 3.15E+00 9.0 1.23 YES NIA PB09-03300 PB09-03301 912312009 Soil PBRF Cs-137 pCi/g 4.60E-01 4.40E-01 1.50E-01 6.0 0.96 YES NIA PB09-03320 PB09-03321 912312009 Soil PBRF K-40 pCi/g 1.59E+01 1.43E+01 3.40E+00 9.0 0.90 YES N/A PB09-03320 PB09-03321 9/2312009 Soil PBRF Cs-137 pCilg 4.10E-01 2.70E-01 1.40E-01 6.0 0.66 YES NIA c-----
PB09-03340 PB09-03341 912312009 Soil PBRF K-40 pCi/g 2.13E+01 1.98E+01 4.ooE+00 11.0 0.93 YES N/A PB09-03360 PB09-03361 912412009 Soil PBRF K-40 pCi/g 1.72E+01 1.66E+01 3.60E+00 10.0 0.97 YES NIA PB09-03360 PB09-03361 912412009 Soil PBRF Cs-137 pCi/g 4.20E-01 4.20E-01 1.20E-01 7.0 1.00 YES N/A PB09-03380 PB09-03381 912412009 Soil PBRF K-40 pCi/g 1.50E+01 1.65E+01 2.30E+00 13.0 1.10 YES NIA
~ ----
PB09-03380 PB09-03381 912412009 Soil PBRF Cs-137 pCi/g 3.30E-01 3.10E-01 9.ooE-02 7.0 0.94 YES NIA --
PB09-03400 PB09-03401 912412009 Soil PBRF K-40 pCilg 1.67E+01 1.66E+01 3.40E+00 10.0 0.99 YES N/A PB09-034oo PB09-03401 912412009 Soil PBRF Cs-137 pCilg 4.60E-01 4.30E-01 1.40E-01 7.0 0.93 YES NIA PB09-03420 PB09-03241 912412009 Soil PBRF K-40 pCi/g 1.91E+01 1.60E+01 3.20E+00 12.0 0.84 YES NIA
~-
PB09-03440 PB09-03441 912512009 Soil PBRF K-40 pCi/g 2.04E+01 1.90E+01 3.80E+00 11.0 0.93 YES NIA 24
I INTRA-LABORATORY COMPARISON (REPLICATE) RESULTS Replicate c
SDR c
Gamma Log SamplelD Original 0
fl)
Number Acquisition Sample Analysis Original Replicate E
Number Number Nuclide Units 2 Sigma
- J Ratio SDR-Date Type Performed Result Result (5
fl)
(Original)
(Replicate)
Uncertainty
(/)
f!:!
09 By fl)
!if a::
PB09-03440 PB09-03441 912512009 Soil PBRF Cs-137 pCilg 4.50E-01 5.90E-01 1.40E-01 6.0 1.31 YES N/A
--- ~--------
PB09-03460 PB09-03461 9/2512009 Soil PBRF K-40 pCi/g 1.42E+01 1.79E+01
- 3. 1OE+oo 9.0 1.26 YES N/A PB09-03460 PB09-03461 9/2512009 Soil PBRF Cs-137 pCi/g 4.60E-01 6.20E-01 1.40E-01 7.0 1.35 YES N/A PB09-03480 PB09-03481 9/2812009 Soil PBRF K-40 pCilg 2.17E+01 1.84E+01 3.90E+00 11.0 0.85 YES N/A r----------
PB09-035oo PB09-03501 9/2912009 Water PBRF K-40 pCilg 5.80E-01 7.90E-01 1.50E-01 8.0 1.36 YES N/A PB09-035oo PB09-03501 9/2912009 Water PBRF H3 pCilml
<MDA
<MDA NlA N/A N/A YES N/A f-------
PB09-03520 PB09-03521 9/2812009 Soil PBRF K-40 pCilg 1.53E+01 1.69E+01 3.50E+00 9.0 1.10 YES N/A r--------
PB09-03520 PB09-03521 912812009 Soil PBRF Cs-137 pCi/g 4.80E-01 4.60E-01 1.60E-01 6.0 0.96 YES NlA PB09-03540 PB09-03541 912812009 Soil PBRF K-40 pCilg 1.61E+01 1.64E+01 3.50E+00 9.0 1.02 YES N/A PB09-03540 PB09-03541 912812009 Soil PBRF Cs-137 pCilg 7.3OE-01 8.00E-01 1.90E-01 8.0 1.10 YES N/A PB09-03560 PB09-03561 9/2912009 Soil PBRF K-40 pCilg 1.90E+01 1.73E+01 2.50E+00 15.0 0.91 YES N/A PB09-03560 PB09-03561 912912009 Soil PBRF Cs-137 pCilg 1.80E-01 7.ooE-02 7.44E-02 5.0 0.39 NO 006 PB09-03560 PB09-03561 9/2912009 Soil PBRF Cs-137 pCi/g
<MDA
<MDA N/A N/A N/A YES N/A PB09-03580 PB09-03581 912912009 Soil PBRF K-40 pCilg 2.25E+01 1.79E+01 3.80E+00 12.0 0.80 YES N/A PB09-03600 PB09-03601 912912009 Soil PBRF K-40 pCilg 1.64E+01 1.98E+01 3.50E+00 9.0 1.21 YES N/A PB09-036oo PB09-03601 9/2912009 Soil PBRF Cs-137 pCilg 5.00E-01 7.60E-01 1.60E-01 6.0 1.52 YES N/A PB09-03620 PB09-03621 9/3012009 Water PBRF K-40 pCilg 6.90E-01 6.3OE-01 1.40E-01 10.0 0.91 YES NlA PB09-03620 PB09-03621 9/3012009 Water PBRF H3 pCilml
<MDA
<MDA N/A N/A N/A YES N/A 25 INTRA-LABORATORY COMPARISON (REPLICATE) RESULTS Replicate c
SDR c
Gamma Log SamplelD Original 0
fl)
Number Acquisition Sample Analysis Original Replicate E
Number Number Nuclide Units 2 Sigma
- J Ratio SDR-Date Type Performed Result Result (5
fl)
(Original)
(Replicate)
Uncertainty
(/)
f!:!
09-By fl)
!if a::
PB09-03440 PB09-03441 912512009 Soil PBRF Cs-137 pCilg 4.50E-01 5.90E-01 1.40E-01 6.0 1.31 YES N/A
~--------
PB09-03460 PB09-03461 9/2512009 Soil PBRF K-40 pCi/g 1.42E+01 1.79E+01
- 3. 1 OE+oo 9.0 1.26 YES N/A PB09-03460 PB09-03461 9/2512009 Soil PBRF Cs-137 pCi/g 4.60E-01 6.20E-01 1.40E-01 7.0 1.35 YES N/A PB09-03480 PB09-03481 9/2812009 Soil PBRF K-40 pCilg 2.17E+01 1.84E+01 3.90E+00 11.0 0.85 YES N/A r-----------
PB09-035oo PB09-03501 9/2912009 Water PBRF K-40 pCilg 5.80E-01 7.90E-01 1.50E-01 8.0 1.36 YES N/A PB09-035oo PB09-03501 9/2912009 Water PBRF H3 pCilml
<MDA
<MDA NlA N/A N/A YES N/A f--------
PB09-03520 PB09-03521 9/2812009 Soil PBRF K-40 pCilg 1.53E+01 1.69E+01 3.50E+00 9.0 1.10 YES N/A r---------
PB09-03520 PB09-03521 912812009 Soil PBRF Cs-137 pCi/g 4.80E-01 4.60E-01 1.60E-01 6.0 0.96 YES NlA PB09-03540 PB09-03541 912812009 Soil PBRF K-40 pCilg 1.61E+01 1.64E+01 3.50E+00 9.0 1.02 YES N/A PB09-03540 PB09-03541 912812009 Soil PBRF Cs-137 pCilg 7.3OE-01 8.00E-01 1.90E-01 8.0 I 1.10 YES N/A PB09-03560 PB09-03561 9/2912009 Soil PBRF K-40 pCilg 1.90E+01 1.73E+01 2.50E+00 15.0 0.91 YES N/A PB09-03560 PB09-03561 912912009 Soil PBRF Cs-137 pCilg 1.80E-01 7.ooE-02 7.44E-02 5.0 0.39 NO 006 PB09-03560 PB09-03561 9/2912009 Soil PBRF Cs-137 pCi/g
<MDA
<MDA N/A N/A N/A YES N/A PB09-03580 PB09-03581 912912009 Soil PBRF K-40 pCilg 2.25E+01 1.79E+01 3.80E+00 12.0 0.80 YES N/A PB09-03600 PB09-03601 912912009 Soil PBRF K-40 pCilg 1.64E+01 1.98E+01 3.50E+00 9.0 1.21 YES N/A PB09-036oo PB09-03601 9/2912009 Soil PBRF Cs-137 pCilg 5.00E-01 7.60E-01 1.60E-01 6.0 1.52 YES N/A PB09-03620 PB09-03621 9/3012009 Water PBRF K-40 pCilg 6.90E-01 6.3OE-01 1.40E-01 10.0 0.91 YES NlA PB09-03620 PB09-03621 9/3012009 Water PBRF H3 pCilml
<MDA
<MDA N/A N/A N/A YES N/A 25
INTRA-LASORA TORY COMPARISON (REPLICATE) RESULTS Replicate c
SDR c
Gamma Log Sample ID Original g
Q)
Number Number Number Acquisition Sample Analysis Nuclide Units Original Replicate 2 Sigma
- J Ratio E
SDR-Date Type Performed Result Result
~
Q)
I (Original)
(Replicate)
Uncertainty
~
09 By Q)
Jf 0:::
PB09-03640 PB09-03641 9/3012009 Soil PBRF K-40 pCilg 1.67E+01 1.48E+01 3.20E+00 10.0 0.89 YES N/A PB09-03640 PB09-03641 913012009 Soil PBRF Cs-137 pCilg 5.50E-01 5.70E-01 1.50E-01 7.0 1.04 YES N/A PB09-03660 PB09-03661 913012009 Soil PBRF K-40 pCilg 1.75E+01 1.72E+01 3.50E+00 10.0 0.98 YES N/A PB09-03660 PB09-03661 9/3012009 Soil PBRF Cs-137 pCi/g 6.20E-01 5.90E-01 1.70E-01 7.0 0.95 YES N/A PB09-03680 PB09-03681 913012009 Soil PBRF K-40 pCilg 1.60E+01 1.69E+01 3.20E+00 10.0 1.06 YES N/A PB09-03680 PB09-03681 913012009 Soil PBRF Cs-137 pCilg 6.30E-01 5.3OE-01 1.60E-01 8.0 0.84 YES N/A PB09-037oo PB09-03701 10/112009 Water PBRF K-40 pCilg 4.50E-01 6.60E-01 1.20E-01 8.0 1.47 YES N/A PB09-03700 PB09-03701 10/112009 Water PBRF H3 pCilml
<MDA
<MDA N/A N/A N/A YES N/A PB09-03720 PB09-03n1 10/112009 Soil PBRF K-40 pCi/g 1.37E+01 1.51E+01 3.20E+00 9.0 1.10 YES N/A PB09-03720 PB09-03721 10/112009 Soil PBRF Cs-137 pCilg 2.3OE-01 3.40E-01 1.ooE-01 5.0 1.48 YES N/A PB09-03740 PB09-03741 10/112009 Soil PBRF K-40 pCilg 4.60E+00 4.80E+00 1.20E+00 8.0 1.04 YES N/A PB09-03760 PB09-03761 10/512009 Water PBRF K-40 pCi/g
<MDA
<MDA N/A N/A N/A YES N/A PB09-03780 PB09-03781 101612009 Soil PBRF K-40 pCi/g 1.87E+01 1.34E+01 3.80E+00 10.0 o.n YES N/A PB09-03800 PB09-03801 10nl2009 Soil PBRF K-40 pCi/g 1.39E+01 1.65E+01 2.88E+00 10.0 1.19 YES N/A PB09-03800 PB09-03801 10nl2009 Soil PBRF Cs-137 pCilg 3.60E-01 3.20E-01 1.20E-01 6.0 0.89 YES N/A PB09-03820 PB09-03821 10nl2009 Soil PBRF K-40 pCi/g 1.55E+01 1.37E+01 3.10E+00 10.0 0.88 YES N/A PB09-03820 PB09-03821 10nl2009 Soil PBRF Cs-137 pCi/g 3.90E-01 3.30E-01 1.24E-01 6.0 0.85 YES N/A 26 INTRA-LASORA TORY COMPARISON (REPLICATE) RESULTS Replicate c
SDR c
Gamma Log Sample ID Original g
Q)
Number Number Number Acquisition Sample Analysis Nuclide Units Original Replicate 2 Sigma
- J Ratio E
SDR-Date Type Performed Result Result
~
Q)
(Original)
(Replicate)
Uncertainty
~
09-By Q)
Jf 0:::
PB09-03640 PB09-03641 9/3012009 Soil PBRF K-40 pCilg 1.67E+01 1.48E+01 3.20E+00 10.0 0.89 YES N/A PB09-03640 PB09-03641 913012009 Soil PBRF Cs-137 pCilg 5.50E-01 5.70E-01 1.50E-01 7.0 1.04 YES N/A PB09-03660 PB09-03661 913012009 Soil PBRF K-40 pCilg 1.75E+01 1.72E+01 3.50E+00 10.0 0.98 YES N/A PB09-03660 PB09-03661 9/3012009 Soil PBRF Cs-137 pCi/g 6.20E-01 5.90E-01 1.70E-01 7.0 0.95 YES N/A PB09-03680 PB09-03681 913012009 Soil PBRF K-40 pCilg 1.60E+01 1.69E+01 3.20E+00 10.0 1.06 YES N/A PB09-03680 PB09-03681 913012009 Soil PBRF Cs-137 pCilg 6.30E-01 5.3OE-01 1.60E-01 8.0 0.84 YES N/A PB09-037oo PB09-03701 10/112009 Water PBRF K-40 pCilg 4.50E-01 6.60E-01 1.20E-01 8.0 1.47 YES N/A
~ES PB09-03700 PB09-03701 10/112009 Water PBRF H3 pCilml
<MDA
<MDA N/A N/A N/A N/A PB09-03720 PB09-03n1 10/112009 Soil PBRF K-40 pCi/g 1.37E+01 1.51E+01 3.20E+00 9.0 1.10 YES N/A
-~--.-
PB09-03720 PB09-03721 10/112009 Soil PBRF Cs-137 pCilg 2.3OE-01 3.40E-01 1.ooE-01 5.0 1.48 YES N/A PB09-03740 PB09-03741 10/112009 Soil PBRF K-40 pCilg 4.60E+00 4.80E+00 1.20E+00 8.0 1.04 YES N/A PB09-03760 PB09-03761 10/512009 Water PBRF K-40 pCi/g
- 8. 1 OE-01 5.00E-01 2.ooE-01 8.0 0.62 YES N/A --
PB09-03760 PB09-03761 10/512009 Water PBRF H3 pCilml
<MDA
<MDA N/A N/A N/A YES N/A PB09-03780 PB09-03781 101612009 Soil PBRF K-40 pCi/g 1.87E+01 1.34E+01 3.80E+00 10.0 o.n YES N/A PB09-03800 PB09-03801 10nl2009 Soil PBRF K-40 pCi/g 1.39E+01 1.65E+01 2.88E+00 10.0 1.19 YES N/A PB09-03800 PB09-03801 10nl2009 Soil PBRF Cs-137 pCilg 3.60E-01 3.20E-01 1.20E-01 6.0 0.89 YES N/A PB09-03820 PB09-03821 10nl2009 Soil PBRF K-40 pCi/g 1.55E+01 1.37E+01 3.10E+00 10.0 0.88 YES N/A PB09-03820 PB09-03821 10nl2009 Soil PBRF Cs-137 pCi/g 3.90E-01 3.30E-01 1.24E-01 6.0 0.85 YES N/A 26
INTRA-LABORATORY COMPARISON (REPLICATE) RESULTS Replicate c:
SDR c:
Gamma Log Sample ID Original
~
Ql Number Number Number Acquisition Sample Analysis Nuclide Units Original Replicate 2 Sigma
- l Ratio E
SDR-Date Type Performed Result Result "0
Ql (Original)
(Replicate)
Uncertainty II)
~
09 By Ql Cl c:::
<{
- If.
PB09-03840 PB09-03841 10lB12oo9 Water PBRF K-40 pCi/g 3.50E-01 6.50E-01 1.35E-01 5.0 1.B6 YES N/A PB09-03840 PB09-03841 10lB12009 Water PBRF H3 pCi/ml
<MDA
<MDA NlA N/A NlA YES N/A -
PB09-03860 PB09-03B61 10lB12009 Soil PBRF K-40 pCi/g 1.66E+01 1.B8E+01 3.50E+00 9.0 1.13 YES N/A PB09-03860 PB09-03861 10/812009 Soil PBRF Cs-137 pCi/g 2.70E-01 2.50E-01 1.10E-01 5.0 0.93 YES N/A PB09-03BBO PB09-03BB1 10/812009 Soil PBRF K-40 pCi/g 1.37E+01 1.47E+01 2.95E+00 9.0 1.07 YES N/A -
PB09-03880 PB09-03881 10/812009 Soil PBRF Cs-137 pCi/g 2.00E-01 1.40E-01 9.ooE-02 4.0 0.70 YES N/A PB09-03900 PB09-03901 10/1212009 Soil PBRF K-40 pCi/g 1.51E+01 1.35E+01 3.13E+00 10.0 0.89 YES N/A PB09-03920 PB09-03921 10/12/2009 Soil PBRF K-40 pCi/g 1.50E+01 1.48E+01 2.30E+00 13.0 0.99 YES N/A PB09-03940 PB09-03941 10/1212009 Soil PBRF K-40 pCi/g 1.56E+01 1.09E+01 3.10E+00 10.0 0.70 YES N/A PB09-03940 PB09-03941 1011212009 Soil PBRF Cs-137 pCi/g 2.50E+00 2.80E+00 3.20E+00 1.6 1.12 YES NlA PB09-03960 PB09-03961 1011312009 Soil PBRF K-40 pCi/g 1.4BE+01 1.58E+01 3.20E+00 9.0 1.0B YES N/A PB08-03980 PB08-03981 1011412009 Soil PBRF K-40 pCi/g 1.25E+01 1.66E+01 2.90E+00 9.0 1.33 YES N/A PB08-03980 PB08-03981 10/14/2009 Soil PBRF Cs-137 pCilg 3.40E-01 3.40E*01 1.20E-01 6.0 1.00 YES N/A PBOB-04oo0 PB08-04001 1011412009 Soil PBRF K-40 pCilg 1.32E+01 8.10E+00 2.70E+00 10.0 0.61 YES N/A PBOB-040oo PB08-04001 10/1412009 Soil PBRF Cs-137 pCilg 2.40E*01 2.90E-01 9.30E-02 5.0 1.21 YES N/A
-~
PB08-04020 PB08-04021 10/1512009 Soil PBRF K-40 pCilg 1.67E+01 1.44E+01 2.20E+00 15.0 0.B6 YES NlA f----
PBOB-04040 PB08-04041 10/1512009 Soil PBRF K-40 pCi/g 1.43E+01 1.B7E+01 2.20E+00 13.0 1.31 YES N/A PB08-04040 PB08-04041 10/15/2009 Soil PBRF Cs-137 pCi/g 1.20E-01 2.20E-01 5.20E-02 5.0 1.83 YES N/A 27 INTRA-LABORATORY COMPARISON (REPLICATE) RESULTS Replicate c:
SDR c:
Gamma Log Sample ID Original
~
Ql Number Number Number Acquisition Sample Analysis Nuclide Units Original Replicate 2 Sigma
- l Ratio E
SDR-Date Type Performed Result Result "0
Ql (Original)
(Replicate)
Uncertainty II)
~
09-By Ql Cl c:::
<{
- If.
PB09-03840 PB09-03841 10lB12oo9 Water PBRF K-40 pCi/g 3.50E-01 6.50E-01 1.35E-01 5.0 1.B6 YES N/A PB09-03840 PB09-03841 10lB12009 Water PBRF H3 pCi/ml
<MDA
<MDA NlA N/A NlA YES N/A --
PB09-03860 PB09-03B61 10lB12009 Soil PBRF K-40 pCi/g 1.66E+01 1.B8E+01 3.50E+00 9.0 1.13 YES N/A PB09-03860 PB09-03861 10/812009 Soil PBRF Cs-137 pCi/g 2.70E-01 I 2.50E-01 1.10E-01 5.0 0.93 YES N/A PB09-03BBO PB09-03BB1 10/812009 Soil PBRF K-40 pCi/g 1.37E+01 1.47E+01 2.95E+00 9.0 1.07 YES N/A --
PB09-03880 PB09-03881 10/812009 Soil PBRF Cs-137 pCi/g 2.00E-01 1.40E-01 9.ooE-02 4.0 0.70 YES N/A PB09-03900 PB09-03901 10/1212009 Soil PBRF K-40 pCi/g 1.51E+01 1.35E+01 3.13E+00 10.0 0.89 YES N/A PB09-03920 PB09-03921 10/12/2009 Soil PBRF K-40 pCi/g 1.50E+01 1.48E+01 2.30E+00 13.0 0.99 YES N/A PB09-03940 PB09-03941 10/1212009 Soil PBRF K-40 pCi/g 1.56E+01 1.09E+01 3.10E+00 10.0 0.70 YES N/A PB09-03940 PB09-03941 1011212009 Soil PBRF Cs-137 pCi/g 2.50E+00 2.80E+00 3.20E+00 1.6 1.12 YES NlA PB09-03960 PB09-03961 1011312009 Soil PBRF K-40 pCi/g 1.4BE+01 1.58E+01 3.20E+00 9.0 1.0B YES N/A PB08-03980 PB08-03981 1011412009 Soil PBRF K-40 pCi/g 1.25E+01 1.66E+01 2.90E+00 9.0 1.33 YES N/A PB08-03980 PB08-03981 10/14/2009 Soil PBRF Cs-137 pCilg 3.40E-01 3.40E*01 1.20E-01 6.0 1.00 YES N/A PBOB-04oo0 PB08-04001 1011412009 Soil PBRF K-40 pCilg 1.32E+01 8.10E+00 2.70E+00 10.0 0.61 YES N/A PBOB-040oo PB08-04001 10/1412009 Soil PBRF Cs-137 pCilg 2.40E*01 2.90E-01 9.30E-02 5.0 1.21 YES N/A
-~
PB08-04020 PB08-04021 10/1512009 Soil PBRF K-40 pCilg 1.67E+01 1.44E+01 2.20E+00 15.0 0.B6 YES NlA PBOB-04040 PB08-04041 10/1512009 Soil PBRF K-40 pCi/g 1.43E+01 1.B7E+01 2.20E+00 13.0 1.31 YES N/A PB08-04040 PB08-04041 10/15/2009 Soil PBRF Cs-137 pCi/g 1.20E-01 2.20E-01 5.20E-02 5.0 1.83 YES N/A
~--
27
INTRA-LABORATORY COMPARISON (REPLICATE) RESULTS Replicate c::
SDR c::
Gamma Log Sample ID Original 0
(1)
Number Acquisition Sample Analysis Original Replicate E
Number Number Nuclide Units 2 Sigma
- J Ratio SDR-Date Type Performed Result Result (5
(1)
(Original)
(Replicate)
Uncertainty I/)
~
09 By (1)
- t a::
PB08-04060 PB08-04061 10/1512009 Soil PBRF K-40 pCi/g 1.46E+01 1.77E+01 3.10E+00 9.0 1.21 YES N/A
'----~~ ~
~ ~-~~ ~
PB08-04080 PB08-040B1 10/1912009 Soil PBRF K-40 pCi/g 1.62E+01 1.B2E+01 3.30E+00 10.0 1.12 YES N/A PB08-04100 PBOB-04101 10/19/2009 Soil PBRF K-40 pCi/g 1.43E+01 1.BOE+01 2.BOE+00 10.0 1.26 YES N/A
~~-
PB08-04120 PB08-04121 10120/2009 Soil PBRF K-40 pCi/g 1.36E+01 1.50E+01 2.90E+00 9.0 1.10 YES N/A
~~- r-~
PBOB-04120 PBOB-04121 1012012009 Soil PBRF Cs-137 pCi/g 2.BOE-01 2.10E-01 1.10E-01 5.0 0.75 YES N/A PB08-04140 PB08-04141 1012012009 Soil PBRF K-40 pCi/g 1.B7E+01 1.71E+01 3.60E+00 10.0 0.91 YES N/A
~~-
~-~
~ ~~ r~
PBOB-04160 PBOB-04161 1012012009 Water PBRF K-40 pCi/g 4.ooE-01 7.50E-01 1.30E-01 6.0 1.BB YES N/A
~-~
~~~-
~~~-
-~
~~~~ ~-~~-
PB08-04160 PB08-04161 1012012009 Water PBRF H3 pCilml
<MDA
<MDA N/A N/A N/A YES N/A PBOB-041BO PBOB-04181 10120/2009 Soil PBRF K-40 pCi/g 1.63E+01 1.43E+01 3.30E+00 10.0 O.BB YES N/A
!--~-
PBOB-04200 PBOB-04201 1012112009 Soil PBRF K-40 pCi/g 1.60E+01 1.39E+01 3.40E+00 9.0 0.87 YES N/A
~-~
PB08-04200 PB08-04201 1012112009 Soil PBRF Cs-137 pCi/g 4.20E-01 3.BOE-01 1.40E-01 6.0 0.90 YES N/A
~-~
PBOB-04220 PBOB-04221 1012112009 Soil PBRF K-40 pCi/g 1.76E+01 1.5BE+01 3.30E+00 11.0 0.90 YES N/A
~-~ ~~~~
PB08-04240 PB08-04241 10121/2009 Water PBRF K-40 pCi/g 6.10E-01 6.30E-01 2.60E-01 5.0 1.03 YES N/A
-~~
PBOB-04240 PBOB-04241 1012112009 Water PBRF H3 pCi/ml
<MDA
<MDA N/A N/A N/A YES N/A
~~~-
~~~~~~~-
PB08-04260 PB08-04261 1012212009 Soil PBRF K-40 pCi/g 1.38E+01 1.45E+01 2.90E+00 10.0 1.05 YES N/A PBOB-042BO PB08-042B1 1012212009 Soil PBRF K-40 pCi/g 1.53E+01 1.72E+01 3.20E+00 10.0 1.12 YES N/A PBOB-04300 PBOB-04301 1012212009 Soil PBRF K-40 pCi/g 1.90E+01 2.10E+01 3.70E+00 10.0 1.11 YES N/A PB08-04320 PB08-04321 1012612009 Soil PBRF K-40 pCi/g 1.2BE+01 1.41E+01 3.ooE+00 9.0 1.10 YES N/A
~~-
~~-~~-
28 INTRA-LABORATORY COMPARISON (REPLICATE) RESULTS Replicate c::
SDR c::
Gamma Log Sample ID Original 0
(1)
Number Acquisition Sample Analysis Original Replicate E
Number Number Nuclide Units 2 Sigma
- J Ratio SDR-Date Type Performed Result Result (5
(1)
(Original)
(Replicate)
Uncertainty I/)
~
09-By (1)
- t a::
PB08-04060 PB08-04061 10/1512009 Soil PBRF K-40 pCi/g 1.46E+01 1.77E+01 3.10E+00 9.0 1.21 YES N/A I---~~~
~~-~~~
PB08-04080 PB08-040B1 10/1912009 Soil PBRF K-40 pCi/g 1.62E+01 1.B2E+01 3.30E+00 10.0 1.12 S
N/A PB08-04100 PBOB-04101 10/19/2009 _
Soil PBRF K-40 pCi/g 1.43E+01 1.BOE+01 2.BOE+00 10.0 1.26 YES N/A
~~-
PB08-04120 PB08-04121 10120/2009 Soil PBRF K-40 pCi/g 1.36E+01 1.50E+01 2.90E+00 9.0 1.10 YES N/A
~~-~~
PBOB-04120 PBOB-04121 1012012009 Soil PBRF Cs-137 pCi/g 2.BOE-01 2.10E-01 1.10E-01 5.0 0.75 YES N/A
-~~~
PB08-04140 PB08-04141 1012012009 Soil PBRF K-40 pCi/g 1.B7E+01 1.71E+01 3.60E+00 10.0 0.91 YES N/A
~~-
~-~
~ ~~ L~~ ~
PBOB-04160 PBOB-04161 1012012009 I
Water PBRF K-40 pCi/g 4.ooE-01 7.50E-01 1.30E-01 6.0
- 1.
YES N/A
~-~
~~~-
~~~-
-~
~~~~ ~-~~-
PB08-04160 PB08-04161 1012012009 Water PBRF H3 pCilml
<MDA
<MDA N/A N/A N/A YES N/A PBOB-041BO PBOB-04181 I
10120/2009 Soil PBRF K-40 pCi/g 1.63E+01 1.43E+01 3.30E+00 10.0 O.BB YES N/A
~~-
PBOB-04200 PBOB-04201 1012112009 Soil PBRF K-40 pCi/g 1.60E+01 1.39E+01 3.40E+00 9.0 0.87 YES N/A _
~-~
PB08-04200 PB08-04201 1012112009 Soil PBRF Cs-137 pCi/g 4.20E-01 3.BOE-01 1.40E-01 6.0 0.90 YES N/A
~-~
PBOB-04220 PBOB-04221 1012112009 Soil PBRF K-40 pCi/g 1.76E+01 1.5BE+01 3.30E+00 11.0 0.90 YES N/A
~-~
-~
PB08-04240 PB08-04241 10121/2009 Water PBRF K-40 pCi/g 6.10E-01 6.30E-01 2.60E-01 5.0 1.03 YES N/A
f----~~
PBOB-04240 PBOB-04241 1012112009 Water PBRF H3 pCi/ml
<MDA
<MDA N/A N/A N/A YES N/A
~~-
~~~~~~~-
PB08-04260 PB08-04261 1012212009 Soil PBRF K-40 pCi/g 1.38E+01 1.45E+01 2.90E+00 10.0 1.05 YES N/A PBOB-042BO PB08-042B1 1012212009 Soil PBRF K-40 pCi/g 1.53E+01 1.72E+01 3.20E+00 10.0 1.12 YES N/A PBOB-04300 PBOB-04301 1012212009 Soil PBRF K-40 pCi/g 1.90E+01 2.10E+01 3.70E+00 10.0 1.11 YES N/A PB08-04320 PB08-04321 1012612009 Soil PBRF K-40 pCi/g 1.2BE+01 1.41E+01 3.ooE+00 9.0 1.10 YES N/A
~~-
~~-~
28
INTRA-LABORATORY COMPARISON (REPLICATE) RESULTS Replicate c
SDR c
Gamma Log SamplelD Original 0
Q)
Number Acquisition Sample Analysis Original Replicate
+=l E
Number Number Nuclide Units 2 Sigma
- J Ratio SDR-Date Type Performed Result Result (5
Q)
(Original)
(Replicate)
Uncertainty
- g I!:!
09 By 0::::
- if PB08-04320 PB08-04321 1012612009 Soil PBRF Cs-137 pCilg 4.20E-01 4.10E-01 1.40E-01 6.0 0.98 YES N/A PB08-04340 PB08-04341 1012612009 Soil PBRF K-40 pCilg 1.B6E+01 1.77E+01 3.40E+00 11.0 0.95 YES N/A -
PBOB-04360 PBOB-04361 1012612009 Soil PBRF K-40 pCilg 1.3BE+01 1.60E+01 3.20E+00 9.0 1.16 YES NlA PB08-04360 PB08-04361 1012612009 Soil PBRF Cs-137 pCi/g 7.00E-01 6.40E-01 1.BOE-01 B.O 0.91 YES N/A PB08-043BO PB08-043B1 1012712009 Soil PBRF K-40 pCilg 1.29E+01 1.43E+01 3.20E+00 B.O 1.11 YES N/A PBOB-04380 PBOB-04381 1012712009 Soil PBRF Cs-137 pCi/g 4.71E+01 4.75E+01 1.96E+00 4B.0 1.01 YES N/A PB08-04400 PB08-04401 1012712009 Water PBRF K-40 pCilg
<MDA
<MDA N/A N/A N/A YES N/A PBOB-044OO PBOB-04401 1012712009 Water PBRF H3 pCilml
<MDA
<MDA N/A N/A N/A YES N/A PBOB-04420 PBOB-04421 1012912009 Water PBRF K-40 pCi/g 7.ooE-01 9.ooE-01 1.80E-01 B.O 1.29 YES NlA PB08-04440 PBOB-04441 1012912009 Soil PBRF K-40 pCi/g 1.31E+01 1.24E+01 3.10E+00 B.O 0.95 YES NlA
~------
PBOB-04440 PBOB-04441 1012912009 Soil PBRF Cs-137 pCi/g 2.BOE-01 2.40E-01 1.10E-01 5.0 0.86 YES N/A PB08-04460 PBOB-04461 1012912009 Soil PBRF K-40 pCi/g 1.57E+01 1.74E+01 3.50E+00 9.0 1.11 YES NlA PB08-04460 PB08-04461 10129/2009 Soil PBRF Cs-137 pCilg 1.90E-01 1.50E-01 9.70E-02 3.9 0.79 YES N/A PBOB-044BO PB08-04481 10129/2009 Soil PBRF K-40 pCi/g 1.63E+01 1.6BE+01 3.40E+00 10.0 1.03 YES N/A PB08-04500 PBOB-04501 1012912009 Soil PBRF K-40 pCi/g 1.77E+01 1.B4E+01 3.60E+00 10.0 1.04 YES NlA PB09-04520 PB09-04521 111212009 Soil PBRF K-40 pCilg 1.75E+01 1.62E+01 2.44E+00 14.0 0.93 YES N/A f--
PB09-04540 PB09-04541 111212009 Soil PBRF K-40 pCi/g 2.02E+01 1.62E+01 3.50E+00 12.0 O.BO YES N/A PB09-04560 PB09-04561 111212009 Soil PBRF K-40 pCi/g 1.B2E+01 1.85E+01 3.60E+00 10.0 1.02 YES N/A 29 INTRA-LABORATORY COMPARISON (REPLICATE) RESULTS Replicate c
SDR c
Gamma Log SamplelD Original 0
Q)
Number Acquisition Sample Analysis Original Replicate
+=l E
Number Number Nuclide Units 2 Sigma
- J Ratio SDR-Date Type Performed Result Result (5
Q)
(Original)
(Replicate)
Uncertainty
- g I!:!
09-By 0::::
. YES N/A PB08-04340 PB08-04341 1012612009 Soil PBRF K-40 pCilg 1.B6E+01 1.77E+01 3.40E+00 11.0 0.95 YES N/A --
PBOB-04360 PBOB-04361 1012612009 Soil PBRF K-40 pCilg 1.3BE+01 1.60E+01 3.20E+00 9.0 1.16 YES NlA PB08-04360 PB08-04361 1012612009 Soil PBRF Cs-137 pCi/g 7.00E-01 6.40E-01 1.BOE-01 B.O 0.91 YES N/A
-~
PB08-043BO PB08-043B1 1012712009 Soil PBRF K-40 pCilg 1.29E+01 1.43E+01 3.20E+00 B.O 1.11 YES N/A PBOB-04380 PBOB-04381 1012712009 Soil PBRF Cs-137 pCi/g 4.71E+01
<MDA
<MDA N/A N/A N/A YES N/A PBOB-044OO PBOB-04401 1012712009 Water PBRF H3 pCilml
<MDA
<MDA N/A N/A N/A YES N/A PBOB-04420 PBOB-04421 1012912009 Water PBRF K-40 pCi/g 7.ooE-01 9.ooE-01 1.80E-01 B.O 1.29 YES NlA PB08-04440 PBOB-04441 1012912009 Soil PBRF K-40 pCi/g 1.31E+01 1.24E+01 3.10E+00 B.O 0.95 YES NlA PBOB-04440 PBOB-04441 1012912009 Soil PBRF Cs-137 pCi/g 2.BOE-01 2.40E-01 1.10E-01 5.0 0.86 YES N/A PB08-04460 PBOB-04461 1012912009 Soil PBRF K-40 pCi/g 1.57E+01 1.74E+01 3.50E+00 9.0 1.11 YES NlA PB08-04460 PB08-04461 10129/2009 Soil PBRF Cs-137 pCilg 1.90E-01 1.50E-01 9.70E-02 3.9 0.79 YES N/A PBOB-044BO PB08-04481 10129/2009 Soil PBRF K-40 pCi/g 1.63E+01 1.6BE+01 3.40E+00 10.0 1.03 YES N/A PB08-04500 PBOB-04501 1012912009 Soil PBRF K-40 pCi/g 1.77E+01 1.B4E+01 3.60E+00 10.0 1.04 YES NlA PB09-04520 PB09-04521 111212009 Soil PBRF K-40 pCilg 1.75E+01 1.62E+01 2.44E+00 14.0 0.93 YES N/A PB09-04540 PB09-04541 111212009 Soil PBRF K-40 pCi/g 2.02E+01 1.62E+01 3.50E+00 12.0 O.BO YES N/A PB09-04560 PB09-04561 111212009 Soil PBRF K-40 pCi/g 1.B2E+01 1.85E+01 3.60E+00 10.0 1.02 YES N/A 29
INTRA*LABORATORY COMPARISON (REPLICATE) RESULTS Replicate c:
SDR c:
Gamma Log Sample 10 Original 0
(I)
Number Number Number Acquisition Sample Analysis Nuclide Units Original Replicate 2 Sigma 5
Ratio E
SDR-Date Type Performed Result Result "0
(I)
(Original)
(Replicate)
Uncertainty
(/)
~
09 By (I)
~
0:::
PB09-04580 PB09-04581 11/312009 Soil PBRF K-40 pCi/g 1.21E+01 1.26E+01 1.60E+00 15.0 1.04 YES N/A i---....
1---..
PB09-04600 PB09-04601 111312009 Soil PBRF K-40 pCi/g 1.53E+01 1.99E+01 3.10E+00 10.0 1.30 YES N/A PB09-04620 PB09-04621 111312009 Soil PBRF K-40 pCi/g 1.26E+01 1.46E+01 2.80E+00 9.0 1.16 YES N/A PB09-04620 PB09-04621 11/312009 Soil PBRF Cs-137 pCilg 2.20E-01 1.30E-01 9.40E-02 5.0 0.59 YES NlA PB09-04640 PB09-04641 111312009 Soil PBRF K-40 pCi/g 1.53E+01 1.68E+01 3.00E+OO 10.0 1.10 YES N/A PB09-04660 PB09-04661 11/412009 Soil PBRF K-40 pCi/g 1.82E+01 2.51E+01 3.62E+OO 10.0 1.38 YES N/A PB09-04680 PB09-04681 11/512009 Soil PBRF K-40 pCi/g 1.47E+01 1.34E+01 2.90E+00 10.0 0.91 YES N/A PB09-047oo PB09-04701 11/512009 Water PBRF K-40 pCilg 5.ooE-01 8.ooE-01 1.20E-01 8.0 1.60 YES N/A PB09-04700 PB09-04701 11/512009 Water PBRF H3 pCi/ml
<MDA
<MDA N/A N/A N/A YES N/A PB09-04720 PB09-04721 111912009 Soil PBRF K-40 pCilg 1.45E+01 1.31E+01
- 3. 1 OE+OO 9.0 0.90 YES N/A
~........-
PB09-04740 PB09-04741 111912009 Soil PBRF K-40 pCi/g 1.46E+01 1.50E+01
- 3. 1OE+oo 9.0 1.03 YES N/A PB09-04760 PB09-04761 1111012009 Soil PBRF K-40 pCi/g 1.67E+01 1.21E+01 2.50E+00 13.0 0.72 YES N/A
~..
PB09-04760 PB09-04761 11/1012009 Soil PBRF Cs-137 pCilg 2.70E-01 2.00E-01 8.00E-02 7.0 0.74 YES NlA r..*..
PB09-04780 PB09-04781 11/10/2009 Soil PBRF K-40 pCi/g 1.60E+01 1.60E+01 3.30E+00 10.0 1.00 YES N/A PB09-04780 PB09-04781 11/1012009 Soil PBRF Cs-137 pCilg 1.65E+00 1.60E+OO 2.70E+00 1.2 0.97 YES N/A PB09-048oo PB09-04801 11/1012009 Soil PBRF K-40 pCilg 1.54E+01 1.60E+01 3.30E+00 9.0 1.04 YES N/A
....r....
PB09-04820 PB09-04821 11/1112009 Soil PBRF K-40 pCi/g 1.38E+01 1.34E+01
- 3. 12E+OO 9.0 0.97 YES N/A PB09-04840 PB09-04841 11/1112009 Soil PBRF K-40 pCilg 1.56E+01 1.69E+01 3.44E+OO 9.0 1.08 YES N/A
~~...
30 I
INTRA*LABORA TORY COMPARISON (REPLICATE) RESULTS Replicate c:
SDR c:
Gamma Log Sample 10 Original 0
(I)
Number Number Number Acquisition Sample Analysis Nuclide Units Original Replicate 2 Sigma 5
Ratio E
SDR-Date Type Performed Result Result "0
(I)
(Original)
(Replicate)
Uncertainty
(/)
~
09-By (I)
~
0:::
I PB09-04580 PB09-04581 11/312009 Soil PBRF K-40 pCi/g 1.21E+01 1.26E+01 1.60E+00 15.0 1.04 YES N/A c--....
PB09-04600 PB09-04601 111312009 Soil PBRF K-40 pCi/g 1.53E+01 1.99E+01 3.10E+00 10.0 1.30 YES N/A 1---
PB09-04620 PB09-04621 111312009 Soil PBRF K-40 pCi/g 1.26E+01 1.46E+01 2.80E+00 9.0 1.16 YES N/A
~
PB09-04620 PB09-04621 11/312009 Soil PBRF Cs-137 pCilg 2.20E-01 1.30E-01 9.40E-02 5.0 0.59 NlA _
PB09-04640 PB09-04641 111312009 Soil PBRF K-40 pCi/
1.53E+01 1.68E+01 3.00E+OO 10.0 1.10 YES N/A PB09-04660 PB09-04661 11/412009 Soil PBRF K-40 pCi/g 1.82E+01 2.51E+01 3.62E+OO 10.0 1.38 YES N/A PB09-04680 PB09-04681 11/512009 Soil PBRF K-40 pCi/g 1.47E+01 1.34E+01 2.90E+00 10.0 0.91 Y
N/A PB09-047oo PB09-04701 11/512009 Water PBRF K-40 pCilg 5.ooE-01 8.ooE-01 1.20E-01 8.0 1.60 YES N/A PB09-04700 PB09-04701 11/512009 Water PBRF H3 pCi/ml
<MDA
<MDA N/A N/A N/A YES N/A PB09-04720 PB09-04721 111912009 Soil PBRF K-40 pCilg 1.45E+01 1.31E+01
- 3. 1 OE+OO 9.0 0.90 YES N/A 1---...
PB09-04740 PB09-04741 111912009 Soil PBRF K-40 pCi/g 1.46E+01 1.50E+01
- 3. 1 OE+oo 9.0 1.03 YES N/A PB09-04760 PB09-04761 1111012009 Soil PBRF K-40 pCi/g 1.67E+01 1.21E+01 2.50E+00 13.0 0.72 YES N/A PB09-04760 PB09-04761 11/1012009 Soil PBRF Cs-137 pCilg I 2.70E-01 2.00E-01 8.00E-02 7.0 0.74 YES NlA PB09-04780 PB09-04781 11/10/2009 Soil PBRF K-40 pCi/g 1.60E+01 1.60E+01 3.30E+00 10.0 1.00 YES N/A PB09-04780 PB09-04781 11/1012009 Soil PBRF Cs-137 r;Cilg 1.65E+00 1.60E+OO 2.70E+00 1.2 0.97 YES N/A
~
PB09-048oo PB09-04801 11/1012009 Soil PBRF K-40 pCilg
- 1.54E+01 1.60E+01 3.30E+00 9.0 1.04 S
N/A _
PB09-04820 PB09-04821 11/1112009 Soil PBRF K-40 pCi/g 1.38E+01 1.34E+01
- 3. 12E+OO 9.0 0.97_ YES N/A PB09-04840 PB09-04841 11/1112009 Soil PBRF K-40 pCilg 1.56E+01 1.69E+01 3.44E+OO 9.0 1.08 YES N/A 30
INTRA-LASORA TORY COMPARISON (REPLICATE) RESULTS Gamma Log Number (Original)
Sample ID Number (Replicate)
Acquisition Date Sample Type Replicate Analysis Performed By Nuclide Units Original Result Replicate Result Original 2 Sigma Uncertainty c:
0
- I
- J (5
f/)
(I) 0:::
Ratio
....c:
(I)
E (I) l!!
~
- If.
PB09-04860 PB09-04861 11/1212009 Puck PBRF K40 pCi/g 1.11E+01 6.70E+00 2.84E+00 8.0 0.60 YES N/A PB09-04860 PB09-04861 11/1212009 Puck PBRF Cs-137 K40 pCi/g 9.10E+00 9.20E+00 6.90E+00 2.6 1.01 YES N/A PB08-04880 PB08-04881 11/1612009 Puck PBRF pCi/g 9.20E+00 7.70E+00 2.30E+00 8.0 0.84 YES N/A PB08-04900 PB08-04901 11/17/2009 Puck PBRF K-40 pCi/g 9.30E+00 5.60E+00 2.45E+00 8.0 0.60 YES N/A PB08-049oo PB08-04901 11117/2009 Puck PBRF Cs-137 pCi/g 5.34E+00 5.36E+00 4.90E+00 2.2 1.00 YES N/A PB08-04920 PB08-04921 11/18/2009 11/1812009 Puck PBRF K-40 pCi/g 6.ooE+00 1.08E+01 2.ooE+00 6.0 1.80 YES N/A PB08-04920 PB08-04921 Puck PBRF Cs-137 pCi/g 4.30E-01 6.60E-01 1.70E-01 5.0 1.53 YES N/A PB08-04940 PB08-04941 11/1812009 Puck PBRF K-40 pCi/g 5.98E+00 9.86E+00 1.87E+00 6.0 1.65 1.00 YES N/A PB08-04940 PB08-04941 11/1812009 Puck PBRF Cs-137 pCi/g 9.60E+00 9.60E+00 6.50E+00 3.0 YES N/A PB08-04960 PB08-04961 1112312009 Soil PBRF K40 pCilg 1.35E+01 1.64E+01 3.23E+00 8.0 1.21 YES N/A PB08-04960 PB08-04961 1112312009 Soil PBRF PBRF Cs-137 pCi/g 4.40E-01 4.80E-01 1.50E-01 6.0 1.09 YES N/A PB08-04980 PB08-04981 1112312009 125 K40 pCilg 1.02E+01 1.ooE+01 2.27E+00 9.0 0.98 YES N/A -
N/A PB08-04980 PB08-04981 11123/2009 125 PBRF PBRF Cs-137 pCi/g 2.90E-01 3.60E-01 9.90E-02 6.0 1.24 YES f-PB08-05000 PB08-05OO1 1112412009 Soil K-40 pCilg 1.17E+01 1.21E+01 2.70E+00 9.0 1.03 YES N/A PB08-05020 PBOS-05021 1112412009 Soil PBRF K-40 pCi/g 1.55E+01 1.30E+01 3.10E+00 10.0 0.84 YES NlA PB08-05020 PBOS-05021 1112412009 Soil PBRF Cs-137 pCi/g 3.30E-01 3.90E-01 1.10E-01 6.0 1.1S YES N/A PBOS-05040 PB08-05041 1112412009 Soil PBRF K-40 pCi/g 1.06E+01 7.S0E+00 2.70E+00 S.O 0.74 YES N/A PBOS-05060 PB08-05061 1112512009 Soil PBRF K-40 pCilg 1.42E+01 1.3SE+01 3.10E+00 9.0 0.97 YES N/A 31 INTRA-LASORA TORY COMPARISON (REPLICATE) RESULTS Replicate c:
SDR c:
Gamma Log Sample ID Original 0
(I)
Number Acquisition Sample Analysis Original Replicate
- I E
Number Number Nuclide Units 2 Sigma
- J Ratio SDR-Date Type Performed Result Result (5
(I)
(Original)
(Replicate)
Uncertainty f/)
l!!
09-By (I)
~
0:::
- If.
PB09-04860 PB09-04861 11/1212009 Puck PBRF K40 pCi/g 1.11E+01 6.70E+00 2.84E+00 8.0 0.60 YES N/A PB09-04860 PB09-04861 11/1212009 Puck PBRF Cs-137 pCi/g 9.10E+00 9.20E+00 6.90E+00 2.6 1.01 YES N/A PB08-04880 PB08-04881 11/1612009 Puck PBRF K40 pCi/g 9.20E+00 7.70E+00 2.30E+00 8.0 0.84 YES N/A PB08-04900 PB08-04901 11/17/2009 Puck PBRF K-40 pCi/g 9.30E+00 5.60E+00 2.45E+00 8.0 0.60 YES N/A PB08-049oo PB08-04901 11117/2009 Puck PBRF Cs-137 pCi/g 5.34E+00 5.36E+00 4.90E+00 2.2 1.00 YES N/A PB08-04920 PB08-04921 11/18/2009 Puck PBRF K-40 pCi/g 6.ooE+00 1.08E+01 2.ooE+00 6.0 1.80 YES N/A PB08-04920 PB08-04921 11/1812009 Puck PBRF Cs-137 pCi/g 4.30E-01 6.60E-01 1.70E-01 5.0 1.53 YES N/A PB08-04940 PB08-04941 11/1812009 Puck PBRF K-40 pCi/g 5.98E+00 9.86E+00 1.87E+00 6.0 1.65 YES N/A PB08-04940 PB08-04941 11/1812009 Puck PBRF Cs-137 pCi/g 9.60E+00 9.60E+00 6.50E+00 3.0 1.00 YES N/A PB08-04960 PB08-04961 1112312009 Soil PBRF K40 pCilg 1.35E+01 1.64E+01 3.23E+00 8.0 1.21 YES N/A PB08-04960 PB08-04961 1112312009 Soil PBRF Cs-137 pCi/g 4.40E-01 4.80E-01 1.50E-01 6.0 1.09 YES N/A PB08-04980 PB08-04981 1112312009 125 PBRF K40 pCilg 1.02E+01 1.ooE+01 2.27E+00 9.0 0.98 YES N/A --
PB08-04980 PB08-04981 11123/2009 125 PBRF Cs-137 pCi/g 2.90E-01 3.60E-01 9.90E-02 6.0 1.24 YES N/A PB08-05000 PB08-05OO1 1112412009 Soil PBRF K-40 pCilg 1.17E+01 1.21E+01 2.70E+00 9.0 1.03 YES N/A PB08-05020 PBOS-05021 1112412009 Soil PBRF K-40 pCi/g 1.55E+01 1.30E+01 3.10E+00 10.0 0.84 YES NlA PB08-05020 PBOS-05021 1112412009 Soil PBRF Cs-137 pCi/g 3.30E-01 3.90E-01 1.10E-01 6.0 1.1S YES N/A PBOS-05040 PB08-05041 1112412009 Soil PBRF K-40 pCi/g 1.06E+01 7.S0E+00 2.70E+00 S.O 0.74 YES N/A PBOS-05060 PB08-05061 1112512009 Soil PBRF K-40 pCilg 1.42E+01 1.3SE+01 3.10E+00 9.0 0.97 YES N/A --
31
INTRA-LABORATORY COMPARISON (REPLICATE) RESULTS Replicate c
C SDR Gamma Log SamplelD Original 0
CJ)
Number Acquisition Sample Analysis Original Replicate E
Number Number Nuclide Units 2 Sigma
- J Ratio SDR-Date Type Performed Result Result (5
~
(Original)
(Replicate)
Uncertainty I/)
09 By CJ)
- t 0:::
PB08-05080 PB08-05081 1113012009 Soil PBRF K-40 pCi/g 1.45E+01 1.22E+01 2.95E+00 10.0 0.84 YES N/A PB08-05100 PB08-05101 1113012009 Soil PBRF K-40 pCi/g 1.51E+01 1.73E+01 3.23E+00 9.0 1.15 YES N/A
-r-~~--~
~-~
PB08-05120 PB08-05121 11/3012009 Soil PBRF K-40 pCi/g 1.58E+01 1.67E+01 3.50E+00 9.0 1.06 YES N/A
~---
~
PB08-05120 PB08-05121 1113012009 Soil PBRF Cs-137 pCi/g 4.20E-01 5.30E-01 1.40E-01 6.0 1.26 YES N/A
~--
PB08-05140 PB08-05141 11/3012009 Soil PBRF K-40 pCi/g 1.47E+01 1.39E+01 3.20E+00 9.0 0.95 YES N/A PB08-05140 PB08-05141 11/3012009 Soil PBRF Cs-137 pCi/g 2.10E-01 2.10E-01 9.50E-02 4.0 1.00 YES N/A PB09-05160 PB09-05161 12/112009 Soil PBRF K-40 pCi/g 1.40E+01 1.38E+01 3.22E+00 9.0 0.99 YES N/A PB09-05160 PB09-05161 12/112009 Soil PBRF Cs-137 pCi/g 2.10E-01 2.40E-01 1.ooE-01 4.0 1.14 YES N/A
-~
PB09-05180 PB09-05181 121112009 Soil PBRF K-40 pCi/g 7.80E+00 7.10E+00 2.3OE+00 7.0 0.91 YES N/A r-~~~
PB09-052oo PB09-05201 12f2f2009 Soil PBRF K-40 pCi/g 1.56E+01 1.35E+01 3.20E+00 10.0 0.87 YES N/A PB09-052OO PB09-05201 12f2f2oo9 Soil PBRF Cs-137 pCi/g 7.20E-01 5.20E-01 1.70E-01 8.0 0.72 YES N/A PB09-05220 PB09-05221 121212009 Soil PBRF K-40 pCilg 1.68E+01 1.54E+01 3.20E+00 11.0 0.92 YES N/A PB09-05220 PB09-05221 12f2f2009 Soil PBRF Cs-137 pCi/g 2.3OE-01 3.30E-01 9.50E-02 5.0 1.43 YES N/A PB09-05240 PB09-05241 121212009 Soil PBRF K-40 pCilg 1.50E+01 1.35E+01 2.80E+00 11.0 0.90 YES N/A
-~
PB09-05260 PB09-05261 12/312009 Soil PBRF K-40 pCi/g 1.58E+01 1.53E+01 3.20E+00 10.0 0.97 YES N/A
--~
PB09-05280 PB09-05281 121812009 Soil PBRF K-40 pCi/g 1.31E+01 1.66E+01 2.70E+00 10.0 1.27 YES N/A PB09-05280 PB09-05281 12/812009 Soil PBRF Cs-137 pCi/g 1.80E-01 2.60E-O1 8.10E-02 4.0 1.44 YES N/A PB09-05300 PB09-05301 1219f2009 Water PBRF K-40 pCi/g 6.00E-01 4.90E-01 2.10E-01 6.0 0.82 YES N/A
~-
~
32 I
INTRA-LABORATORY COMPARISON (REPLICATE) RESULTS Replicate c
C SDR Gamma Log SamplelD Original 0
CJ)
Number Acquisition Sample Analysis Original Replicate E
Number Number Nuclide Units 2 Sigma
- J Ratio SDR-Date Type Performed Result Result (5
~
(Original)
(Replicate)
Uncertainty I/)
09-By CJ)
- t 0:::
PB08-05080 PB08-05081 1113012009 Soil PBRF K-40 pCilg 1.45E+01 1.22E+01 2.95E+00 10.0 0.84 I YES N/A PB08-05100 PB08-05101 1113012009 Soil PBRF K-40 pCilg 1.51E+01 1.73E+01 3.23E+00 9.0 1.15 YES N/A
-~~--~
~-~
I PB08-05120 PB08-05121 11/3012009 Soil PBRF K-40 pCilg 1.58E+01 1.67E+01 3.50E+00 9.0 1.06 YES N/A
~---
~~
PB08-05120 PB08-05121 1113012009 Soil PBRF Cs-137 pC~ 4.20E-01 5.30E-01 1.40E-01 6.0 1.26 YES N/A f-------~
~--~~
~~-f----~
~--
PB08-05140 PB08-05141 11/3012009 Soil PBRF K-40 pCi/g 1.47E+01 1.39E+01 3.20E+00 9.0 0.95 YES N/A PB08-05140 PB08-05141 11/3012009 Soil PBRF Cs-137 pCilg 2.10E-01 2.10E-01 9.50E-02 4.0 1.00 YES N/A PB09-05160 PB09-05161 12/112009 Soil PBRF K-40 pCilg 1.40E+01 1.38E+01 3.22E+00 9.0 0.99 YES N/A PB09-05160 PB09-05161 12/112009 Soil PBRF Cs-137 pCi/g 2.10E-01 2.40E-01 1.ooE-01 4.0 1.14 YES N/A PB09-05180
-~
PB09-05181 121112009 Soil PBRF K-40 pCi/g 7.80E+00 7.10E+00 2.3OE+00 7.0 0.91 YES N/A I--~~~
PB09-052oo PB09-05201 12f2f2009 Soil PBRF K-40 pCi/g 1.56E+01 1.35E+01 3.20E+00 10.0 0.87 YES N/A PB09-052OO PB09-05201 12f2f2oo9 Soil PBRF Cs-137 pCi/g 7.20E-01 5.20E-01 1.70E-01 8.0 0.72 YES N/A PB09-05220 PB09-05221 121212009 Soil PBRF K-40 pCilg 1.68E+01 1.54E+01 3.20E+00 11.0 0.92 YES N/A
~
~
~
PB09-05220 PB09-05221 12f2f2009 Soil PBRF Cs-137 pCi/g 2.3OE-01 3.30E-01 9.50E-02 5.0 1.43 YES N/A PB09-05240 PB09-05241 121212009 Soil PBRF K-40 pCilg 1.50E+01 1.35E+01 2.80E+00 11.0 0.90 YES N/A
-~
PB09-05260 PB09-05261 12/312009 Soil PBRF K-40 pCi/g 1.58E+01 1.53E+01 3.20E+00 10.0 0.97 YES N/A
--~
PB09-05280 PB09-05281 121812009 Soil PBRF K-40 pCilg 1.31E+01 1.66E+01 2.70E+00 10.0 1.27 YES N/A PB09-05280 PB09-05281 12/812009 Soil PBRF Cs-137 pCi/g 1.80E-01
- 2. 60 E-O 1 8.10E-02 4.0 1.44 YES N/A PB09-05300 PB09-05301 1219f2009 Water PBRF K-40 pCi/g 6.00E-01 4.90E-01 2.10E-01 6.0 0.82 YES N/A
~-
~
32
INTRA-LABORATORY COMPARISON (REPLICATE) RESULTS Replicate c:
SDR c:
Gamma Log Sample ID Original
.Q (J.)
Number Acquisition Sample Analysis Original Replicate E
Number Number Nuclide Units 2 Sigma (5
Ratio (J.)
SDR (Original)
(Replicate)
Date Type Performed Result Result Uncertainty (I) tI!
09 By (J.)
- f cr
tI##
PB09-05300 PB09-05301 121912009 Water PBRF H3 pCi/ml
<MDA
<MDA N/A N/A N/A YES N/A PB09-05320 PB09-05321 121912009 Soil PBRF K-40 pCilg 1.37E+01 1.27E+01 2.80E+00 10.0 0.93 YES N/A PB09-05320 PB09-05321 121912009 Soil PBRF Cs-137 pCi/g 1.50E-01 2.80E-01 7.30E-02 4.0 1.87 YES N/A PB09-05340 PB09-05341 121912009 Soil PBRF K-40 pCi/g 1.54E+01 1.73E+01 3.10E+00 10.0 1.12 YES NlA
-~~~
PB09-05340 PB09-05341 121912009 Soil PBRF Cs-137 pCi/g 3.00E-01 3.80E-01 1.10E-01 5.0 1.27 YES N/A
~~~~~
~-
PB09-05360 PB09-05361 1211012009 Soil PBRF K-40 pCilg 1.48E+01 1.64E+01 3.10E+00 10.0 1.11 YES N/A
~-~
~~~ f-~~~~-
PB09-05360 PB09-05361 12/10/2009 Soil PBRF Cs-137 pCi/g 4.30E-01 2.60E-01 1.30E-01 7.0 0.60 YES N/A
~~-~~-
PB09-05380 PB09-05381 1211412009 Water PBRF K-40 pCilg 1.10E+00 8.80E-01 3.50E-01 6.0 0.80 YES N/A
~~~~-,
~-~-
PB09-05380 PB09-05381 12/14/2009 Water PBRF H3 pCi/g
<MDA
<MDA N/A N/A N/A YES N/A PB09-05400 PB09-05401 12115/2009 Soil PBRF K-40 pCilg 1.76E+01 1.69E+01 3.20E+00 11.0 0.96 YES N/A
~-
PB09-05400 PB09-05401 1211512009 Soil PBRF Cs-137 pCi/g 2.40E+00 2.2DE+OO 3.20E+00 1.5 0.92 YES N/A c--~~~~-
PB08-05420 PB08-05421 12/15/2009 Soil PBRF K-40 pCi/g 1.60E+01 1.3SE+01 3.20E+00 10.0 0.S6 YES N/A
-~~~~-~~
~~- ------
~-
PB08-05420 PB08-05421 12/1512009 Soil PBRF Cs-137 pCilg 1.S0E-01 2.ooE-01 S.60E-02 4.0 1.11 YES N/A
~~-
-~~~
~~~~
PB08-05440 PBOS-05441 12115/2009 Water PBRF K-40 pCi/g 7.70E-01 4.90E-01 2.10E-01 7.0 0.64 YES N/A
!---~
PB08-05460 PB08-05461 12/16/2009 Soil PBRF K-40 pCilg 1.57E+01 1.41E+01 3.ooE+OO 10.0 0.90 YES N/A PB08-05460 PB08-05461 12116/2009 Soil PBRF Cs-137 pCi/g 4.00E-01 2.50E-01 1.23E-01 7.0 0.63 YES N/A
-~~~~
PBOS-05480 PBOS-05481 1211612009 Water PBRF K-40 pCilg 5.9OE-01 S.10E-01 2.50E-01 5.0 1.37 YES N/A f-~~~~-~~
PBOS-054S0 PBOS-05481 1211612009 Water PBRF H3 pCilg
<MDA
<MDA N/A N/A N/A YES N/A
~~~~-
~~-~
-~~-
33 INTRA-LABORATORY COMPARISON (REPLICATE) RESULTS Replicate c:
SDR c:
Gamma Log Sample ID Original
.Q (J.)
Number Acquisition Sample Analysis Original Replicate E
Number Number Nuclide Units 2 Sigma (5
Ratio (J.)
SDR-(Original)
(Replicate)
Date Type Performed Result Result Uncertainty (I) tI!
09-By (J.)
- f cr
tI##
PB09-05300 PB09-05301 121912009 Water PBRF H3 pCi/ml
<MDA
<MDA N/A N/A N/A YES N/A PB09-05320 PB09-05321 121912009 Soil PBRF K-40 pCilg 1.37E+01 1.27E+01 2.80E+00 10.0 0.93 YES N/A PB09-05320 PB09-05321 121912009 Soil PBRF Cs-137 pCi/g 1.50E-01 2.80E-01 7.30E-02 4.0 1.87 I YES N/A PB09-05340 PB09-05341 121912009 Soil PBRF K-40 pCi/g 1.54E+01 1.73E+01 3.10E+00 10.0 1.12 YES NlA
-~~~
I------~~
PB09-05340 PB09-05341 121912009 Soil PBRF Cs-137 pCi/g 3.00E-01 3.80E-01 1.10E-01 5.0 1.27 YES N/A
... ~
~-
PB09-05360 PB09-05361 1211012009 Soil PBRF K-40 1.48E+01 1.64E+01 3.10E+00 10.0 1.11 YES N/A
~-~
~~~
~Cs-~;;-
pCi/g E-01 PB09-05360 PB09-05361 12/10/2009 Soil PBRF 2.60E-01 1.30E-01 7.0 0.60 YES N/A
~~~~~-
PB09-05380 PB09-05381 1211412009 Water PBRF K-40 pCilg 1.10E+00 8.80E-01 3.50E-01 6.0 0
YES N/A I-~~
~~~~~ ~
~
~
~
~-~-
PB09-05380 PB09-05381 12/14/2009 Water PBRF H3 pCi/g
<MDA
<MDA N/A N/A N/A YES N/A PB09-05400 PB09-05401 12115/2009 Soil PBRF K-40 ilg 1.76E+01 1.69E+01 3.20E+00 11.0 0.96 YES N/A
~-
PB09-05400 PB09-05401 1211512009 Soil PBRF Cs-137 pCi/g 2.40E+00 2.2DE+OO 3.20E+00 1.5 0.92 YES N/A
-~~~~-
PB08-05420 PB08-05421 12/15/2009 Soil PBRF K-40 pCi/g 1.60E+01 1.3SE+01 3.20E+00 10.0 0.S6 YES N/A r~~~~~~~
~~- -------
PB08-05420 PB08-05421 12/1512009 Soil PBRF Cs-137 pCilg 1.S0E-01 2.ooE-01 S.60E-02 4.0 1.11 YES N/A PB08-05440 PBOS-05441 12115/2009 Water PBRF K-40 pCi/g 7.70E-01 4.90E-01 2.10E-01 7.0 0.64 YES N/A PB08-05460 PB08-05461 12/16/2009 Soil PBRF K-40 pCiI 1.57E+01 1.41E+01 3.ooE+OO 10.0 0.90 YES N/A PB08-05460 PB08-05461 12116/2009 Soil PBRF Cs-137 pCi/g 4.00E-01 2.50E-01 1.23E-01 7.0 0.63 YES N/A
,---~~~~
PBOS-05480 PBOS-05481 1211612009 Water PBRF K-40 pCilg 5.9OE-01 S.10E-01 2.50E-01 5.0 1.37 YES N/A
~~~~
~
~~~~~
PBOS-054S0 PBOS-05481 1211612009 Water PBRF H3 pCilg
<MDA
<MDA N/A N/A N/A YES N/A
~~~~-
~~~~~-
33
INTRA-LABORATORY COMPARISON (REPLICATE) RESULTS Replicate c
SDR c
Gamma Log Sample ID Original 0
Q)
Number Acquisition Sample Analysis Original Replicate
- l E
Number Number Nuclide Units 2 Sigma
- J Ratio SDR-Date Type Performed Result Result "15
~
(Original)
(Replicate)
Uncertainty fI) 09 By Q)
~
a::
- If.
PB08-05500 PB08-05501 1212112009 Soil PBRF K-40 pCi/g 1.57E+01 1.46E+01 3.50E+00 9.0 0.93 YES N/A PB08-05520 PB08-05521 1212212009 Soil PBRF K-40 pCi/g 1.51E+01 1.37E+01 3.ooE+00 10.0 0.91 YES N/A i--~~ ~
~--~~
~-
PB08-05540 PB08-05541 1212212009 Soil PBRF K-40 pCi/g 1.40E+01 1.60E+01 3.20E+00 9.0 1.14 YES N/A
~~~~~-~
--~-
PBOO-05560 PB08-05561 1212312009 Soil PBRF K-40 pCi/g 1.02E+01 1.45E+01 2.85E+00 7.0 1.42 YES N/A
~-~
~-
PBOO-05580 PB08-05581 1212312009 Soil PBRF K-40 pCi/g 1.44E+01 1.19E+01 3.12E+00 9.0 0.83 YES N/A f--------~~-~
~-~
PB08-055oo PBOO-05501 1212112009 Soil PBRF K-40 pCi/g 1.57E+01 1.46E+01 3.50E+00 9.0 0.93 YES N/A
~-
~-~
~--
PBOO-05520 PB08-05521 1212212009 Soil PBRF K-40 pCi/g 1.51E+01 1.37E+01 3.ooE+00 10.0 0.91 YES N/A
~-~
PB08-05540 PBOO-05541 1212212009 Soil PBRF K-40 pCi/g 1.40E+01 1.60E+01 3.20E+00 9.0 1.14 YES N/A
-~~~
PBOO-05560 PB08-05561 1212312009 Soil PBRF K-40 pCi/g 1.02E+01 1.45E+01 2.85E+00 7.0 1.42 YES N/A PBOO-05580 PB08-05581 1212312009 Soil PBRF K-40 pCi/g 1.44E+01 1.19E+01 3.12E+00 9.0 0.83 YES N/A
~-
34 INTRA-LABORATORY COMPARISON (REPLICATE) RESULTS Replicate c
SDR c
Gamma Log Sample ID Original 0
Q)
Number Acquisition Sample Analysis Original Replicate
- l E
Number Number Nuclide Units 2 Sigma
- J Ratio SDR-Date Type Performed Result Result "15
~
(Original)
(Replicate)
Uncertainty fI) 09-By Q)
~
a::
- If.
PB08-05500 PB08-05501 12P112009 Soil PBRF K-40 pCi/g 1.57E+01 1.46E+01 3.50E+00 9.0 0.93 YES N/A PB08-05520 PB08-05521 1212212009 Soil PBRF K-40 pCi/g 1.51E+01 1.37E+01 3.ooE+00 10.0 0.91 YES N/A
-~~--~~
~-
PB08-05540 PB08-05541 1212212009 Soil PBRF K-40 pCi/g 1.40E+01 1.60E+01 3.20E+00 9.0 1.14 YES N/A r-~~-~
--~-
PBOO-05560 PB08-05561 1212312009 Soil PBRF K-40 pCi/g 1.02E+01 1.45E+01 2.85E+00 7.0 1.42 YES N/A
~-~
~-
PBOO-05580 PB08-05581 1212312009 Soil PBRF K-40 pCi/g 1.44E+01 1.19E+01 3.12E+00 9.0 0.83 YES N/A
'-----~~-~
~-~
PB08-055oo PBOO-05501 1212112009 Soil PBRF K-40 pCi/g 1.57E+01 1.46E+01 3.50E+00 9.0 0.93 YES N/A
~-
~-~
~--
PBOO-05520 PB08-05521 1212212009 Soil PBRF K-40 pCi/g 1.51E+01 1.37E+01 3.ooE+00 10.0 0.91 YES N/A
~-~
PB08-05540 PBOO-05541 1212212009 Soil PBRF K-40 pCi/g 1.40E+01 1.60E+01 3.20E+00 9.0 1.14 YES N/A C------~~
PBOO-05560 PB08-05561 1212312009 Soil PBRF K-40 pCi/g 1.02E+01 1.45E+01 2.85E+00 7.0 1.42 YES N/A PBOO-05580 PB08-05581 1212312009 Soil PBRF K-40 pCi/g 1.44E+01 1.19E+01 3.12E+00 9.0 0.83 YES N/A
---~~-
34
I I
I I
I I
I I
I I
I I
I I
I I
I I
I ATTACHMENT 2 Inter-Laboratory Comparison Results 35 I
I I
I I
I I
ATTACHMENT 2 I
Inter-Laboratory Comparison Results I
I I
I I
I I
I I
I I
35
INTER-LABORATORY COMPARISON (REPLICATE) RESULTS Gamma Log Number (Original)
Sample ID Number (Replicate)
Acquisition Date Sample Type Replicate Analysis Performed By Nuclide Units Original Result Replicate Result Original 2 Sigma Uncertainty c:: B
- J "0
(/)
Q) a:::
Ratio c::
Q)
E
~
- f SDR Number SDR 09 PB09-oo857 L39109-3 512912009 Soil TBE Cs-137 pCilg 4.B4E+00 4.90E+OO 1.50E-01 65.0 1.01 YES N/A PB09-00863 L391 09-4 5/2912009 Soil TBE Cs-137 pCi/g 5.35E+00 5.64E+00 1.73E-01 62.0 1.05 YES N/A PBOS-01243 L39336-1 712812009 Soil TBE Cs-137 pCi/g 1.34E+01 1.33E+01 1.15E+00 23.0 1.01 YES N/A PBOS-01279 L39336-2 7/2812009 Soil TBE Cs-137 pCilg 6.83E+00 5.52E+00 8.95E-01 15.0 1.24 YES N/A PBOS-01289 L39336-3 7/2812009 Soil TBE Cs-137 pCilg 9.OSE+01 9.17E+01 3.60E+OO 50.0 0.99 YES N/A PB09-00299 NPB-09-01-3 3/26/2009 Soil GRISE Cs-137 pCi/g 1.74E+00 1.71E+OO 1.80E-01 19.0 1.02 YES N/A PB09-00299 NPB-09-01-3 3126/2009 Soil GRISE Co-60 pCi/g
<MDA
<MDA N/A N/A N/A YES N/A PB09-03274 sssOO06 9/22/2009 Soil GRISE Cs-137 pCi/g
<MDA
<MDA N/A N/A N/A YES N/A PB09-03273 sssOO05 9/2212009 Soil GRISE Cs-137 pCi/g
<MDA
<MDA N/A N/A N/A YES N/A PB09-03275 sssOO07 9/22/2009 Soil GRISE Cs-137 pCi/g
<MDA
<MDA N/A N/A N/A YES N/A PB09-03276 sssoo02 9/22/2009 Soil GRISE Cs-137 pCi/g
<MDA
<MDA N/A N/A N/A YES N/A PB09-03277 sss0012 9/2212009 Soil GRISE Cs-137 pCi/g
<MDA
<MDA N/A N/A N/A YES N/A PB09-03278 sss0013 9/2212009 Soil GRISE Cs-137 Cs-137 pCi/g
<MDA
<MDA N/A N/A N/A YES N/A PB09-03279 sssOO08 9/22/2009 Soil GRISE pCi/g 3.80E-01 3.50E-01 1.30E-01 6.0 1.09 YES N/A PB09-03282 sssOO09 9122/2009 Soil GRISE Cs-137 pCi/g 8.00E-02 8.00E-02 2.00E-02 8.0 1.00 YES N/A PB09-03283 sss0010 9/2212009 Soil Soil GRISE Cs-137 pCi/g 6.00E-02 8.00E-02 2.00E-02 6.0 0.75 YES N/A PB09-03284 sss0011 9/2212009 GRISE Cs-137 pCi/g 7.00E-02 7.00E-02 4.00E-02 3.5 1.00 YES N/A Note:
TBE = Teledyne Brown Engineering GRISE = Gak Ridge Institute for Science and Engineering 36 INTER-LABORATORY COMPARISON (REPLICATE) RESULTS Replicate c::
SDR c::
Gamma Log Sample ID Original B
Q)
Number Number Number Acquisition Sample Analysis Nuclide Units Original Replicate 2 Sigma
- J Ratio E
SDR-Date Type Performed Result Result "0
~
(Original)
(Replicate)
Uncertainty
(/)
09-By Q)
- f a
- ::
PB09-oo857 L391 09-3 512912009 Soil TBE Cs-137 pCilg 4.B4E+00 4.90E+OO 1.50E-01 65.0 I 1.01 YES N/A PB09-00863 L391 09-4 5/2912009 Soil TBE Cs-137 pCi/g 5.35E+00 5.64E+00 1.73E-01 62.0 1.05 YES N/A PBOS-01243 L39336-1 712812009 Soil TBE Cs-137 pCi/g 1.34E+01 1.33E+01 1.15E+00 23.0 1.01 YES N/A PBOS-01279 L39336-2 7/2812009 Soil TBE Cs-137 pCilg 6.83E+00 5.52E+00 8.95E-01 15.0 1.24 YES N/A PBOS-01 L39336-3 7/2812009 Soil TBE Cs-137 pCilg E+01 9.17E+01 3.60E+OO 0.99 YES N/A PB09-00299 NPB-09-01-3 3/26/2009 Soil GRISE Cs-137 pCi/g 1.74E+00 1.71E+OO 1.80E-01 19.0
- 1.
YES N/A 9-00299 NPB-09-01-3 3126/2009 Soil GRISE Co-60 pCi/g
<MDA
<MDA N/A N/A YES PB09-03274 sssOO06 12009 Soil GRISE Cs-137 pCi/g
<MDA
<MDA N/A N/A N/A YES N/A PB09-03273 sssOO05 9/2212009 GRISE Cs-137 p
<MDA
<MDA N/A N/A N/A YES N/A PB09-03275 sssOO07 9/22 Soil GRISE Cs-137
<MDA
<MDA N/A N/A N/A YES N/A PB09-03276 sssoo02 9/22/2009 Soil GRISE Cs-137 pCi/g
<MDA
<MDA N/A N/A N/A YES N/A PB09-03277 sss0012 9/2212009 Soil GRISE Cs-137 pCi/g
<MDA
<MDA N/A N/A N/A YES N/A PB09-03278 sss0013 9/22120 Soil GRISE Cs-137 pCi/g
<MDA
<MDA N/A N/A N/A YES N/A PB09-03279 sssOO08 9/22/2 Soil GRISE Cs-137 pCi/g 3.80E-01 3.50E-01 1.30E-01 6.0 1.09 YES N/A PB09-03282 sssOO09 9122/2009 Soil GRISE Cs-137 pCi/g 8.00E-02 8.00E-02 2.00E-02 8.0 1.00 YES N/A PB09-03283 sss0010 9/2212009 Soil GRISE Cs-137 pCi/g 6.00E-02 8.00E-02 2.00E-02 6.0 0.75 Y~ N/A PB09-03284 sss0011 9/2212009 Soil GRISE Cs-137 pCi/g 7.00E-02 ~
4.00E-02 3.5 1.00~ N/A Note:
TBE = Teledyne Brown Engineering GRISE = Gak Ridge Institute for Science and Engineering 36
INTER-LABORATORY COMPARISON (REPLICATE) RESULTS Replicate c:
SDR c:
Gamma Log SamplelD Original
~
CD Number Number Number Acquisition Sample Analysis Nuclide Units Original Replicate 2 Sigma
- l Ratio E
SDR-Date Type Performed Result Result (5
CD (Original)
(Replicate)
Uncertainty CIl
~
09 By CD
!f a::
PB07-02217 L391 09-5 7/2512007 Soil TBE Co-60 pCi/g 4.94E-01 4.35E-01 6.30E-02 16.0 0.88 YES N/A PB07-02217 L391 09-5 7/2512007 Soil TBE Cs-137 pCilg 7.40E+01 7.24E+01 5.71E-01 259.0 0.98 YES N/A PB07-02813 L391 09-6 9/412007 Soil TBE Co-60 pCi/g 2.54E-01 2.05E-01 7.10E-02 7.0 0.81 YES N/A PB07-02813 L391 09-6 91412007 Soil TBE Cs-137 pCi/g 2.04E+01 2.01E+01 3.83E-01 107.0 0.99 YES N/A PB06-03628 L391 09-7 10124/2006 Soil TBE C0-60 pCi/g 1.63E-01 1.27E-01 4.40E-02 7.0 0.78 YES N/A PB06-03628 L391 09-7 1012412006 Soil TBE Cs-137 pCi/g 9.44E+00 8.52E+00 1.30E-01 145.0 0.90 YES N/A PB07-03657 L391 09-9 111612007 Soil TBE Cs-137 pCilg 1.20E+01 1.20E+01 3.03E-01 79.0 1.00 YES N/A PB07-03210 L391 09-10 101212007 Soil TBE Co-50 pCilg 3.04E-01 2.54E-01
- 7. 14E-02 9.0 0.84 YES N/A PB07-03210 L391 09-10 101212007 Soil TBE Cs-137 pCilg 1.74E+01 1.68E+01 4.14E-01 84.0 0.97 YES N/A Note:
TBE =Teledyne Brown Engineering Archived samples above were re-analyzed on 7123109 for hard-to-detect radionuclides 37 INTER-LABORATORY COMPARISON (REPLICATE) RESULTS Replicate c:
SDR c:
Gamma Log SamplelD Original
~
CD Number Number Number Acquisition Sample Analysis Nuclide Units Original Replicate 2 Sigma
- l Ratio E
SDR-Date Type Performed Result Result (5
CD (Original)
(Replicate)
Uncertainty CIl
~
09-By CD
!f a::
PB07-02217 L391 09-5 7/2512007 Soil TBE Co-60 pCi/g 4.94E-01 4.35E-01 6.30E-02 16.0 0.88 YES N/A PB07-02217 L391 09-5 7/2512007 Soil TBE Cs-137 pCilg 7.40E+01 7.24E+01 5.71E-01 259.0 0.98 YES N/A PB07-02813 L391 09-6 9/412007 Soil TBE Co-60 pCi/g 2.54E-01 2.05E-01 7.10E-02 7.0 0.81 YES N/A PB07-02813 L391 09-6 91412007 Soil TBE Cs-137 pCi/g 2.04E+01 2.01E+01 3.83E-01 107.0 0.99 YES N/A PB06-03628 L391 09-7 10124/2006 Soil TBE C0-60 pCi/g 1.63E-01 1.27E-01 4.40E-02 7.0 0.78 YES N/A PB06-03628 L391 09-7 1012412006 Soil TBE Cs-137 pCi/g 9.44E+00 8.52E+00 1.30E-01 145.0 0.90 YES N/A PB07-03657 L391 09-9 111612007 Soil TBE Cs-137 pCilg 1.20E+01 1.20E+01 3.03E-01 79.0 1.00 YES N/A f----
PB07-03210 L391 09-10 101212007 Soil TBE Co-50 pCilg 3.04E-01 2.54E-01
- 7. 14E-02 9.0 0.84 YES N/A PB07-03210 L391 09-10 101212007 Soil TBE Cs-137 pCilg 1.74E+01 1.68E+01 4.14E-01 84.0 0.97 YES N/A Note:
TBE = Teledyne Brown Engineering Archived samples above were re-analyzed on 7123109 for hard-to-detect radionuclides 37
I I
I I
I I
I I
I I
I I
I I
I I
I I
I Sample Deviation Reports 38 I
I I
I I
I I
I I
Sample Deviation Reports I
I I
I I
I I
I I
I 38
I I
EXHIBIT 2 I
I I
I I
I I
I I
I I
I I
I I
I
.<.ilic;';f<"'~.;:.;{********
.;y;"¢'<;.1i:~rSAMPLE DE~~~N.pPoRT
.....ur.
.....;"~.. J......
SAMPLE LOCATIONIDESCRIPTION IREPORT NUMBER PB09-00140 Replicate not in agreement SDR-09-001 INSTRUMENT (Check One)
Gross Alpha/Beta D Liq. Scint. D Gamma Spec. [8J Serial #
Detector #1 / #3
..-~.
SAMPLE TYPE (Check One) sonD Water/Liquid D Planchet D Concrete Debris D Other [8J Puck SAMPLE START DATEITIME ISAMPLE STOP DATEITIME 1/19/0B/12.59 N/A ANALYTICAL PROBLEM Replicate analysis of PB09-00140 not in agreement between Detector#1 & #3.
Original I Replicate Original Resolutio Agreement I Nuclide Units 2 Sigma Ratio Result i
Result Uncertainty n
K-40 pCi/g 9.BOE+00 I
1.77E+01 2.33E+00 B.O 0.55 NO C~-1:17 nCi/n Q ??F+01 1 fi7F+O?
- 1 fiOF+OO fi30 0.59 NO CORRECTIVE ACTIONS AND/OR COMMENTS Sample was recounted on Detector #2. Agreement was obtained between Detectors 1 & 2.
I Original Replicate Original I
. I I
i Nuclide Units 2 Sigma
. Resolubo. Ratio
- Agreement I Result Result n
I Uncertainty I
I K-40 pCi/g 9.BOE+00 1.06E+01 2.33E+00 B.O 0.92 YES I
Cs-137 pCi/g 9.22E+01 B.51E+01 3.50E+00 53.0 1.0B YES Calibration of puck geometry on Detector #3 was checked and found to be 70% higher than the certificate value. The detector was calibrated on 121BIOB with a new standard. The calibration of the remaining geometries for Detector #3 were checked and found to be satisfactory <<10% of certificate value). The variance between the three detectors on the daily QC Check (47mm Air Filter) is <1%. This detector was recalibrated for this geometry. ORTEC technical personnel have been consulted to determine the cause of this shift. All puck samples counted on Detector #3 since recalibration have been reanalyzed. All calibrations were checked on Detectors 1 &2 and found to be satisfactory. A review of the calibration certificate files was conducted and found that the previous (old) calibration file had incorrectly been selected in the SDF. The correct file was assigned and the old file was removed from the SDF. The laboratory technician was counseled to ensure the correct calibration files are used for analysis. No further action is required.
Submitted By: (Print/Sign) R. Case DATE Radiological Laboratory Manager (Print/Sign) R. Case DATE NASA Project RSO (PrintiSign) W. Stoner DATE I
~
~
I I
I I
I I
I I
I I
I I
I I
I I
I I
EXHIBIT 2
.<.ilic;';f<"'~.;:.;{********
.;y;"¢'<;.1i:~rSAMPLE DE~~~N.pPoRT
..... ur.
.....;"~.. J......
SAMPLE LOCATIONIDESCRIPTION I REPORT NUMBER PB09-00140 Replicate not in agreement SDR-09-001 INSTRUMENT (Check One)
Gross Alpha/Beta D Liq. Scint. D Gamma Spec. [8J Serial #
Detector #1 / #3
.. -~.
SAMPLE TYPE (Check One) sonD Water/Liquid D Planchet D Concrete Debris D Other [8J Puck SAMPLE START DATEITIME I SAMPLE STOP DATEITIME 1/19/0B/12.59 N/A ANALYTICAL PROBLEM Replicate analysis of PB09-00140 not in agreement between Detector#1 & #3.
Original I Replicate Original Resolutio Agreement I Nuclide Units 2 Sigma Ratio Result i
Result Uncertainty n
K-40 pCi/g 9.BOE+00 I
1.77E+01 2.33E+00 B.O 0.55 NO C~-1:17 nCi/n Q ??F+01 1 fi7F+O?
- 1 fiOF+OO fi30 0.59 NO CORRECTIVE ACTIONS AND/OR COMMENTS Sample was recounted on Detector #2. Agreement was obtained between Detectors 1 & 2.
I Original Replicate Original I
. I I
I i
Nuclide Units 2 Sigma
. Resolubo. Ratio
- Agreement Result Result n
I Uncertainty I
I K-40 pCi/g 9.BOE+00 1.06E+01 2.33E+00 B.O 0.92 YES I
Cs-137 pCi/g 9.22E+01 B.51E+01 3.50E+00 53.0 1.0B YES Calibration of puck geometry on Detector #3 was checked and found to be 70% higher than the certificate value. The detector was calibrated on 121BIOB with a new standard. The calibration of the remaining geometries for Detector #3 were checked and found to be satisfactory <<10% of certificate value). The variance between the three detectors on the daily QC Check (47mm Air Filter) is <1%. This detector was recalibrated for this geometry. ORTEC technical personnel have been consulted to determine the cause of this shift. All puck samples counted on Detector #3 since recalibration have been reanalyzed. All calibrations were checked on Detectors 1 &2 and found to be satisfactory. A review of the calibration certificate files was conducted and found that the previous (old) calibration file had incorrectly been selected in the SDF. The correct file was assigned and the old file was removed from the SDF. The laboratory technician was counseled to ensure the correct calibration files are used for analysis. No further action is required.
Submitted By: (Print/Sign) R. Case DATE Radiological Laboratory Manager (Print/Sign) R. Case DATE NASA Project RSO (PrintiSign) W. Stoner DATE I
~
~
I I
EXHIBIT 2 I
I I
I I
I I
I I
I I
I I
I I
I I
SAMPLE LOCATION/DESCRIPTION REPORT NUMBER PB09-00520 Replicate not in agreement SDR-09-002 INSTRUMENT (Check One)
Gross Alpha/Beta 0 Liq. Scinto 0 Gamma Spec. 1:8:1 Serial #
Detector #1 / #3 SAMPLE TYPE (Check One)
Soil D Water/Liquid 1:8:1 Planchet 0 Concrete Debris 0 Other 0 Puck SAMPLE START DATEITIME 4/22/09 1 0939 ANALYTICAL PROBLEM SAMPLE STOP DATEITIME N/A The K-40 result on Detector 3 was not in agreement with K-40 result on Detector 1 on a 2000 second count.
CORRECTIVE ACTIONS AND/OR COMMENTS The sample was reanalyzed for 5000 seconds on Detectors 1 and 3 and found to be in agreement. The sample was also analyzed on Detector 2 for comparison and found to be in agreement with Detectors 1 and 3. No further action is required.
Submitted By: (Print/Sign) R. Case DATE Radiological Laboratory Manager (Print/Sign) R. Case DATE NASA Project RSO (Print/Sign) W. Stoner DATE 40 I
I I
I I
I I
I I
I I
I I
I I
I I
I I
EXHIBIT 2 SAMPLE LOCATION/DESCRIPTION REPORT NUMBER PB09-00520 Replicate not in agreement SDR-09-002 INSTRUMENT (Check One)
Gross Alpha/Beta 0 Liq. Scinto 0 Gamma Spec. [8:1 Serial #
Detector #1 / #3 SAMPLE TYPE (Check One)
Soil D Water/Liquid [8:1 Planchet 0 Concrete Debris 0 Other 0 Puck SAMPLE START DATEITIME 4/22/09 1 0939 ANALYTICAL PROBLEM SAMPLE STOP DATEITIME N/A The K-40 result on Detector 3 was not in agreement with K-40 result on Detector 1 on a 2000 second count.
CORRECTIVE ACTIONS AND/OR COMMENTS The sample was reanalyzed for 5000 seconds on Detectors 1 and 3 and found to be in agreement. The sample was also analyzed on Detector 2 for comparison and found to be in agreement with Detectors 1 and 3. No further action is required.
Submitted By: (Print/Sign) R. Case DATE Radiological Laboratory Manager (Print/Sign) R. Case DATE NASA Project RSO (Print/Sign) W. Stoner DATE 40
I I
I I
I I
I I
I I
I I
I I
I I
I I
I EXHIBIT 2 SAMPLE LOCATION/DESCRIPTION REPORT NUMBER PB09-01060 Replicate not in agreement for Co-60 SDR-09-003 INSTRUMENT (Check One)
Gross Alpha/Beta D Liq. Scinto D Gamma Spec. [8]
Serial #
Detector #1 / #3 SAMPLE TYPE (Check One) sonD Water/Liquid [8]
PlanchetD
..-..~..-
..-..------------v Concrete Debris D Other D Puck SAMPLE START DATEITIME 7/6/0910:03 SAMPLE STOP DATEITIME N/A ANALYTICAL PROBLEM Co-60 was identified in PB09-0160 at.099 +/-.019 pCi/g on Detector #1 (MDA = 0.019). The replicate on Detector #3 did not identify Co-60 (MDA =.015 pCi/g). The result on Detector #1 did not replicate with the Co-60 MDA on Detector #3.
CORRECTIVE ACTIONS AND/OR COMMENTS Sample was recounted for long count (43,200 seconds) on both detectors.C0-60 was <MDA on both detectors
<<0.0038 pCi/g and <0.004 pCi/g). The sample was also counted on Detector #2 for verification and Co-60 was
<MDA (0.004 pCi/g). The Co-60 identified on the initial count was determined to be a false positive result. No further action is required.
Submitted By: (Print/Sign) R. Case DATE:
Radiological Laboratory Manager (Print/Sign) R. Case DATE:
NASA Project RSO (Print/Sign) W. Stoner DATE:
41
~----------------------------~
I I
I I
I I
I I
I I
I I
I I
I I
I I
EXHIBIT 2 SAMPLE LOCATION/DESCRIPTION REPORT NUMBER PB09-01060 Replicate not in agreement for Co-60 SDR-09-003 INSTRUMENT (Check One)
Gross Alpha/Beta D Liq. Scinto D Gamma Spec. [8]
Serial #
Detector #1 / #3 SAMPLE TYPE (Check One) sonD Water/Liquid [8]
PlanchetD SAMPLE START DATEITIME 7/6/0910:03 ANALYTICAL PROBLEM
.. --.. ~.. -
.. --.. ------------v Concrete Debris D Other D Puck SAMPLE STOP DATEITIME N/A Co-60 was identified in PB09-0160 at.099 +/-.019 pCi/g on Detector #1 (MDA = 0.019). The replicate on Detector #3 did not identify Co-60 (MDA =.015 pCi/g). The result on Detector #1 did not replicate with the Co-60 MDA on Detector #3.
CORRECTIVE ACTIONS AND/OR COMMENTS Sample was recounted for long count (43,200 seconds) on both detectors.C0-60 was <MDA on both detectors
<<0.0038 pCi/g and <0.004 pCi/g). The sample was also counted on Detector #2 for verification and Co-60 was
<MDA (0.004 pCi/g). The Co-60 identified on the initial count was determined to be a false positive result. No further action is required.
Submitted By: (Print/Sign) R. Case DATE:
Radiological Laboratory Manager (Print/Sign) R. Case DATE:
NASA Project RSO (Print/Sign) W. Stoner DATE:
I 41
~----------------------------~
I I
I I
I I
I I
I I
I I
I I
I I
I I
EXHIBIT 2
.'ii.t"<~.l'i;~':'\\r
.;F0;~*;li~~'***......
yo SAMPul~RBroRT
..jOT'.<<*
.~...~
\\.:<:
- ,';;;1\\;
SAMPLE LOCATION/DESCRIPTION REPORT NUMBER PB09-02220 Replicate not in agreementfor Cs-137 SDR-09-004 INSTRUMENT (Check One)
Gross Alpha/Beta 0 Liq. Scinto 0 Gamma Spec. [8J Serial #
Detector #1/ #2 L-..__.
SAMPLE TYPE (Check One)
Soil [8J Water/Liquid 0 Planchet 0 Concrete Debris 0 Other 0 Puck SAMPLE START DATEITIME SAMPLE STOP DATEITIME 8/27/09 1133 NIA ANALYTICAL PROBLEM Cs-137 was not identified in original sample (PB-09-02220) but was present in replicate sample (PB09-02221).
Replicate analysis with Cs-137 MDA was not in agreement.
Original i
Original I Replicate i Nuclide Units 2 Sigma Res.
Ratio Agreement Result I
Result Uncertainty K40 1.61E+01 1.69E+01 3.20E+00 10.0 0.95 YES pCi/g 2.64 pCi/g 2.90E-01 1.10E-01
- 1.13E-01 5.0 NO Cs-137 I
- MDA CORRECTIVE ACTIONS AND/OR COMMENTS Sample was recounted for 600 seconds on both detectors. Results were in agreement.
Nuclide Units Original Result Replicate Result Original 2 Sigma Uncertainty Res.
Ratio Agreement I Cs-137 pCi/g 2.70E-01 3.00E-01 B.60E-02 6.0 0.90 YES DATE:
Submitted By: (Print/Sign) R. Case/
DATE:
Radiological Laboratory Manager (Print/Sign) R. Casel DATE:
W. StonerI 42 I~------------------------------~
i I
I I
I I
I I
I I
I I
I I
I I
I I
I EXHIBIT 2 yo SAMPul~RBroRT.~... ~.'ii.t"<~.l'i;~':'\\r
- F0;~*;li~~'***......
.. jOT'.<<*
\\.:<:
- ,';;;1\\;
SAMPLE LOCATION/DESCRIPTION REPORT NUMBER PB09-02220 Replicate not in agreementfor Cs-137 SDR-09-004 INSTRUMENT (Check One)
Gross Alpha/Beta 0 Liq. Scinto 0 Gamma Spec. [8J Serial #
Detector #1/ #2 L-.. __
SAMPLE TYPE (Check One)
Soil [8J Water/Liquid 0 Planchet 0 Concrete Debris 0 Other 0 Puck SAMPLE START DATEITIME SAMPLE STOP DATEITIME 8/27/09 1133 NIA ANALYTICAL PROBLEM Cs-137 was not identified in original sample (PB-09-02220) but was present in replicate sample (PB09-02221).
Replicate analysis with Cs-137 MDA was not in agreement.
i Original I Replicate i Original Nuclide Units Result I
Result 2 Sigma Res.
Ratio Agreement Uncertainty K40 pCi/g 1.61E+01 1.69E+01 3.20E+00 10.0 0.95 YES I Cs-137 pCi/g 2.90E-01 1.10E-01
- 1.13E-01 5.0 2.64 NO
- MDA CORRECTIVE ACTIONS AND/OR COMMENTS Sample was recounted for 600 seconds on both detectors. Results were in agreement.
Original Replicate Original Nuclide Units 2 Sigma Res.
Ratio Agreement Result Result Uncertainty I Cs-137 pCi/g 2.70E-01 3.00E-01 B.60E-02 6.0 0.90 YES Submitted By: (Print/Sign) R. Case/
DATE:
Radiological Laboratory Manager (Print/Sign) R. Casel DATE:
i NASA Project RSO (Print/Sign)
W. Stoner I DATE:
42 I~------------------------------~
I I
I I
I I
I I
I I
I I
I I
I I
I I
I EXHIBIT 2 SAMPLE LOCATION/DESCRIPTION REPORT NUMBER PB09-02240 Replicate not in agreement for Cs137 SDR-09-005 INSTRUMENT (Check One)
Gross AlphalBeta 0 Liq. Scinto 0 Gamma Spec.!:8l Serial #
Detector #1 1#3 SAMPLE TYPE (Check One)
Soil!:8l WaterlLiquid 0 Planchet 0 Concrete Debris 0 Other 0 Puck SAMPLE START DATEITIME
- SAMPLE STOP DATEITIME 8/27/091328 NIA ANALYTICAL PROBLEM Cs-137 was identified in Original sample (PB-09-02240) but was not present in replicate sample (PB09-02241).
Replicate analysis with Cs-137 MDA was not in agreement.
Nuclide K-40 i Cs-137 Units pCilg pCi/g Original Result 1.54E+01 3.15E-01 Replicate Result 1.64E+01 1.10E-01*
Original 2 Sigma Uncertaint 3.00E+00 1.11E-01 Res.
10.0 6.0 Ratio 0.94 2.86 Agreement YES NO
- MDA CORRECTIVE ACTIONS ANDIOR COMMENTS Sample was recounted for 600 seconds on both detectors. Results were in agreement.
Original Nucll'de Unl'ts Original Replicate 2 Sigma R
Ratio Agreement Result Result Uncertaint es.
Cs-137 pCilg 2.70E-01 2.60E-01 B.00E-02 7.0 1.04 YES Submitted By: (Print/Sign) R. Casel DATE:
Radiological Laboratory Manager (Print/Sign) R. Casel DATE:
NASA Project RSO (Print/Sign) W. Stonerl DATE:
~
~----------------------------~
I I
I I
I EXHIBIT 2 SAMPLE LOCATION/DESCRIPTION REPORT NUMBER PB09-02240 Replicate not in agreement for Cs-137 SDR-09-005 INSTRUMENT (Check One)
Gross AlphalBeta 0 Liq. Scinto 0 Gamma Spec.!:8l Serial #
Detector #1 1#3 I
SAMPLE TYPE (Check One)
I I
I I
I I
I I
I I
I I
Soil!:8l WaterlLiquid 0 Planchet 0 SAMPLE START DATEITIME 8/27/091328 ANALYTICAL PROBLEM Concrete Debris 0 Other 0 Puck
- SAMPLE STOP DATEITIME NIA Cs-137 was identified in Original sample (PB-09-02240) but was not present in replicate sample (PB09-02241).
Replicate analysis with Cs-137 MDA was not in agreement.
Original Nuclide Units Original Replicate 2 Sigma Res.
Ratio Agreement Result Result Uncertaint K-40 pCilg 1.54E+01 1.64E+01 3.00E+00 10.0 0.94 YES i Cs-137 pCi/g 3.15E-01 1.10E-01*
1.11E-01 6.0 2.86 NO
- MDA CORRECTIVE ACTIONS ANDIOR COMMENTS Sample was recounted for 600 seconds on both detectors. Results were in agreement.
Original Nucll'de Unl'ts Original Replicate 2 Sigma R
Ratio Agreement Result Result Uncertaint es.
Cs-137 pCilg 2.70E-01 2.60E-01 B.00E-02 7.0 1.04 YES Submitted By: (Print/Sign) R. Casel DATE:
Radiological Laboratory Manager (Print/Sign) R. Casel DATE:
NASA Project RSO (Print/Sign) W. Stonerl DATE:
I
~
~----------------------------~
I I
I I
I I
I I
I I
I I
I I
I I
I I
1 EXHIBIT 2 REPORT NUMBER PB09-03560 Replicate not in agreement for Cs-137 I
SOR-09-006 INSTRUMENT (Check One)
Gross Alpha/Beta 0 LSC 0 Gamma Spec. [8J Serial #
Detector #2 / #3 SAMPLE TYPE (Check One)
Soil[8J Water/Liquid 0 Air Filter 0 Concrete Debris 0 Other 0 Puck SAMPLE START DATEITIME SAMPLE STOP DATEITIME 9/29/09/1242 N/A ANALYTICAL PROBLEM Cs-137 was identified in original sample (PB-09-03560) analyzed on Detector #3, but was not present <<MDA) in replicate sample (PB09-03561) analyzed on Detector #2. Replicate analysis with Cs-137 MDA was not in agreement.
I Original I
I Replicate 2 Sigma Original Units I Res.
Ratio I Nuclide Agreement i Result Result Uncertaint y
K-40 pCi/g 1.90E+01 1.73E+01 2.50E+00 15.0 YES 0.91 Cs-137 1.BOE-01 7.00E-02*
7.44E-02 0.39 NO pCi/g 5.0
- MDA CORRECTIVE ACTIONS ANDIOR COMMENTS Sample was recounted for 600 seconds on both detectors, but was still not in agreement for Cs-137. Sample was counted on Detector #1 and Cs-137 was <MDA. Results were in agreement between Detectors #1 and #2. The original result on Detector #3 had a >40% uncertainty for Cs-137 and is determined to be a false positive result. No further action is required.
DATE:
Submitted By: (Print/Sign) R. Casel DATE:
Radiological Laboratory Manager (Print/Sign) R. Casel DATE:
NASA Project RSO (Print/Sign) W. Stoner/
M
~------------------------------~
I I
I I
I I
I I
I I
I I
I I
I I
I I
EXHIBIT 2 REPORT NUMBER PB09-03560 Replicate not in agreement for Cs-137 I
SOR-09-006 INSTRUMENT (Check One)
Gross Alpha/Beta 0 LSC 0 Gamma Spec. [8J Serial #
Detector #2 / #3 SAMPLE TYPE (Check One)
Soil[8J Water/Liquid 0 Air Filter 0 SAMPLE START DATEITIME 9/29/09/1242 ANALYTICAL PROBLEM Concrete Debris 0 Other 0 Puck SAMPLE STOP DATEITIME N/A Cs-137 was identified in original sample (PB-09-03560) analyzed on Detector #3, but was not present <<MDA) in replicate sample (PB09-03561) analyzed on Detector #2. Replicate analysis with Cs-137 MDA was not in agreement.
I Original I Original I
Agreement i I Nuclide Units Replicate 2 Sigma I Res.
Ratio Result Result Uncertaint y
K-40 pCi/g 1.90E+01 1.73E+01 2.50E+00 15.0 0.91 YES Cs-137 pCi/g 1.BOE-01 7.00E-02*
7.44E-02 5.0 0.39 NO
- MDA CORRECTIVE ACTIONS ANDIOR COMMENTS Sample was recounted for 600 seconds on both detectors, but was still not in agreement for Cs-137. Sample was counted on Detector #1 and Cs-137 was <MDA. Results were in agreement between Detectors #1 and #2. The original result on Detector #3 had a >40% uncertainty for Cs-137 and is determined to be a false positive result. No further action is required.
Submitted By: (Print/Sign) R. Casel DATE:
Radiological Laboratory Manager (Print/Sign) R. Casel DATE:
NASA Project RSO (Print/Sign) W. Stoner/
DATE:
1 M
~------------------------------~
I I
I I
I I
I I
I I
I I
I I
I I
I I
I EXHIBIT 2
<,<f,**,,;.
ijj'ii i
- ii;;}*f
- ;SAMPLE Dqf1~(r,N~POItT
- ~,;;;;;"
X
/.,;;;
- .; ' f ;
- ,';f,,-.i*.*..
SAMPLE LOCATION/DESCRIPTION REPORT NUMBER MAPEP-09-RdF21 Co-60 exceeded Reference value >30%
SDR-09-007 INSTRUMENT (Check One)
Gross Alpha/Beta D LSC D Gamma Spec. 1:8:1 Serial #
Detector #1/ #2/ #3
"--..-~-----"
SAMPLE TYPE (Check One) sonD Water/Liquid D Air Filter 1:8:1 Concrete Debris D OtherD Puck SAMPLE START DATEfriME SAMPLE STOP DATEITIME 9/21/09/1649 NIA ANALYTICAL PROBLEM MAPEP-09-RdF21 Co-60 exceeded reference value of 1.03 Bq by 30.1 %. The acceptable bias is 30%. The reported value for C0-60 was 1.34 +/-0.08 Bq and the Acceptance Range was 0.72-1.34 Bq.
CORRECTIVE ACTIONS AND/OR COMMENTS The sample was analyzed twice on each of the 3 detectors for 43,200 seconds and the results averaged. A review was conducted of the reported results to ensure they were reported correctly. No discrepancies were found. A replicate analysis was performed and the reported value and reference value were in agreement. The spectra for each trial were reviewed for peak shape and uncertainty and no anomalies were found. The sample was re-analyzed on Detector 1 after annual recalibration and the results (1.33 Bq.) were consistent with the reported value. The reported results for this geometry have consistently been biased high compared to the reference value. This has been a recurring problem with this geometry and was reported to ORTEK. Investigation and additional testing is in progress to resolve this issue.
DATE:
Submitted By: (Print/Sign) R. Case/
DATE:
Radiological Laboratory Manager (Print/Sign) R. Case/
DATE:
NASA Project RSO (Print/Sign) W. Stoner/
~
~------------------------------~
I
<,<f,**,,;.
- ii;;}*f
- ;SAMPLE Dqf1~(r,N~POItT ijj' i
- ~,;;;;;"
X ii
/.,;;;
- .; ' f ;
- ,';f,,-. i*.*..
SAMPLE LOCATION/DESCRIPTION REPORT NUMBER EXHIBIT 2 I
I I
MAPEP-09-RdF21 Co-60 exceeded Reference value >30%
INSTRUMENT (Check One)
SDR-09-007 I
Gross Alpha/Beta D LSC D Gamma Spec. 1:8:1 Serial #
Detector #1/ #2/ #3
"--.. -~-----"
SAMPLE TYPE (Check One) sonD Water/Liquid D Air Filter 1:8:1 Concrete Debris D OtherD Puck I
I SAMPLE START DATEfriME SAMPLE STOP DATEITIME 9/21/09/1649 NIA I
ANALYTICAL PROBLEM MAPEP-09-RdF21 Co-60 exceeded reference value of 1.03 Bq by 30.1 %. The acceptable bias is 30%. The reported value for C0-60 was 1.34 +/-0.08 Bq and the Acceptance Range was 0.72-1.34 Bq.
I I
I CORRECTIVE ACTIONS AND/OR COMMENTS The sample was analyzed twice on each of the 3 detectors for 43,200 seconds and the results averaged. A review was conducted of the reported results to ensure they were reported correctly. No discrepancies were found. A replicate analysis was performed and the reported value and reference value were in agreement. The spectra for each trial were reviewed for peak shape and uncertainty and no anomalies were found. The sample was re-analyzed I
on Detector 1 after annual recalibration and the results (1.33 Bq.) were consistent with the reported value. The reported results for this geometry have consistently been biased high compared to the reference value. This has been a recurring problem with this geometry and was reported to ORTEK. Investigation and additional I
I testing is in progress to resolve this issue.
I I
Submitted By: (Print/Sign) R. Case/
DATE:
I Radiological Laboratory Manager (Print/Sign) R. Case/
DATE:
I NASA Project RSO (Print/Sign) W. Stoner/
DATE:
I
~
~------------------------------~
I I
I I
I I
I I
I I
I I
I I
I I
I I
I Cross-Check Reports 46 I
I I
I I
I I
I Cross-Check Reports I
I I
I I
I I
I I
I I
46
P Mixed Anatyte Performance Evaluation Program Department ofF.n~gy RESL - 1955 Fremont Ave. MS4149 - Idaho Falls. ill 83415 Laboratory Results For MAPEP Series 20 (pBRFOI) NASA Phun Brook Reactor Facility Lab 6100 Cohunbus Ave Sandusky, OH 44870
\\1 \\I'EI'-III)-\\laS;!II: Ra,liulu~iC:ll. inlll*l.!anic :Incl 'l'mi-\\ ulalilt" nl"l.!anic, clllllhim'c\\,uil,I:mc\\anl Ref Bias Acceptance Dnc Unc Analy!e Result Value Flag Notes
{%l Range Value Flag Cobalt-57 NR RW (11 )
Nickel-63 NR 514.9 360.4-669.4 Potassium-40 NR 570 399-741 Uranium-2341233 NR 149 104-194 Uranium-238 NR 155 109-202 Americium-241 38.7 38.3 A
1.0 26.8 - 49.8 1.02 L
Cesium-134 NR 467 327-607 Cesium-137 660.2 605 A
9.1 424 -787 7.87 L
Cobalt-60 NR 4.113 Iron-55 NR 983 688-1278 Manganese-54 NR 307 215-399 Plutonium-238 NR 25.3 17.7 -32.9 Plutonium-2391240 NR 0.29 Strontium-go NR 257 180-334 Zine>65 NR 242 169-315 T echnetium-99 NR 171 120-222 Radiological Reference Dme: January 1, 2009
'I \\PEP-Ill). \\ l:l" ~Il : R:uliulul.!ical. in llr:,!:mic comhim'd \\\\ nll' l" 'I:mdanl Ref Bias Acceptance Dnc D ne o
Analy!e Result Value Flag Notes
{%}
Range Value Flag Cobalt-57 21.0 18.9 A
11.1 13.2-24.6 0.07 L
Nickel-63 NR 53.50 37.45-69.55 o
Uranium-2341233 NR 2.77 1.94-3.60 o
Uranium-238 NR 2.88 2.02-3.74 Americium-241 NR 0.636 0.445 - 0.827 Cesium-134 NR 22.5 15.8-29.3 Cesium-137 NR RW (11 )
CobaH-60 17.4 17.21 A
1.1 12.05 - 22.37 0.30 L
33.7-62.7 Iron-55 NR 48.2 o
Manganese-54 NR 14.66 10.26-19.06 NR 1.18 0.83-1.53 Plutonium-238 0.597 -1.109 Plutonium-2391240 NR 0.853 o
5.05-9.37 Strontium-90 NR 7.21 Hydrogen-3 NR 330.9 231.6 -430.2 9.5 - 17.7 Zinc-65 NR 13.6 14.46 10.12-18.80 Technetium-99 NR o
Radiological Reference Dme: Janllary 1, 2009 o
47 II o
o o
o o
o o
EP Mixed Analyte Performance Evaluation Program Department of&ergy RESL - 1955 Fremont A\\*e. MS4149 - Idaho Fall. ID 83415 Laboratory Results For MAPEP Series 20 (pBRFOl) NASA Plum Brook Reactor Facility Lab 6100 Cohunbus Ave Sandusky, OH 44870
\\ J \\ PF I' -11'>-\\ I :IS:!II: R:Hliulugic:ll. inurganic nnd 'l'llli-, 411:11 ill-nrg:mic, cnlllhim',1,oil,1:lnllaHI Ref Bills Acceptance Vnc Vnc Anllly!e Result Value Flag Notes
{%l Range Value Flag Cobalt-57 NR RW (11 )
Nickel-63 NR 514.9 360.4-669.4 Potassium-40 NR 570 399 - 741 Uranium-2341233 NR 149 104-194 Uranium-238 NR 155 109-202 Americium-241 38.7 38.3 A
1.0 26.8-49.8 1.02 L
Cesium-134 NR 467 327-607 Cesium-137 660.2 605 A
9.1 424 -787 7.87 L
Cobalt-60 NR 4.113 Iron-55 NR 983 688-1278 Manganese-54 NR 307 215-399 Plutonium-238 NR 25.3 17.7 -32.9 Plutonium-2391240 NR 0.29 Strontium-90 NR 257 180-334 Zin0-65 NR 242 169-315 T echnetium-99 NR 171 120-222 Radiological Ref erellce D(1fe.* Jalluary 1, 1009
\\ J \\ I'FI'-1I9-\\ J:l" 211: Radiulul!ical. intlr~:mi[ (Ulllhilll'd \\\\ :lIlT 'I"nclanl Ref Bias Acceptance Vuc Vne Analy!e Result Value Flag Notes
{%2 Range Value Flag Cobalt-57 21.0 18.9 A
11.1 13.2-24.6 0.07 L
Nickel-63 NR 53.50 37.45-69.55 Uranium-2341233 NR 2.77 1.94-3.60 Uranium-238 NR 2.88 2.02-3.74 Americium-241 NR 0.636 0.445-0.827 Ceslurn-134 NR 22.5 15.8-29.3 Cesium-137 NR RW (11 )
Cobalt-60 17.4 17.21 A
1.1 12.05 - 22.37 0.30 L
Iron-55 NR 48.2 33.7-62.7 Manganese-54 NR 14.66 10.26 -19.06 Plutonium-238 NR 1.18 0.83-1.53 Plutonium-2391240 NR 0.853 0.597 -1.109 Strontium-90 NR 7.21 5.05-9.37 Hydrogen-3 NR 330.9 231.6 -430.2 Zinc-65 NR 13.6 9.5-17.7 Technetium-99 NR 14.46 10.12-18.80 Radiological Referellce D(1fe: Jalluary 1, 2009 47
o o
o o
o o
o o
o o
o o
'1 \\PEP-1I9-RtlF211 ; R:ulinln:,!ical air filll'!"
Ref Bias Acceptance Uoc Uoc Ana1~e Result Value Flag Notes
{%)
Range Value Flag Cobalt-57 1.30 Uranium-2341233 NR Uranium-238 NR Americium-241 NR Cesium-134 NR Cesium-137 1.72 Cobalt-60 1.46 Manganese-54 NR Plutonium-238 NR Plutonium-2391240 NR Strontitm-90 NR Zinc-65 NR 1.30 0.198 0.21 0.205 2.93 1.52 1.22 2.2709 0.1763 0.157 0.640 1.36 A
0.0 0.91-1.69 0.05 0.139 - 0.257 0.15-0.27 0.144 -0.267 A
A 13.2 19.7 2.05-3.81 1.06-1.98 0.85-1.59 1.5896-2.9522 0.08 0.07 0.1234 - 0.2292 0.110 -0.204 0.448-0.832 0.95-1.77 Radiological Reference Date: Jarl1lan]J, 2009 48 o
o o
o IJ o
o o
o o
o o
\\J \\PEP-III)-UIIF211: R:ulinlu:,!ical air lilll'!"
Radwl\\')~Il:al
{ lnJls (l3q "ample)
Ref Bias Acceptance Uoc Uoc Aual~e Result Value Flag Notes
{%2 Range Value Flag Cobalt-57 1.30 1.30 A 0.0 0.91-1.69 0.05 Uranium-2341233 NR 0.198 0.139 - 0.257 Uranium-238 NR 0.21 0.15-0.27 Americium-241 NR 0.205 0.144 -0.267 Cesium-134 NR 2.93 2.05-3.81 Cesium-137 1.72 1.52 A
13.2 1.06-1.98 0.08 Cobalt-60 1.46 1.22 A 19.7 0.85-1.59 0.07 Manganese-54 NR 2.2709 1.5896-2.9522 Plutonium-238 NR 0.1763 0.1234 - 0.2292 Plutonium-2391240 NR 0.157 0.110 -0.204 Strontium-90 NR 0.640 0.448-0.832 Zinc-65 NR 1.36 0.95-1.77 Rndiological Referellce Date: J0l11/0n' 1. 2009 48
EP Mixed Analyte Performance Evaluation Program Dcpanment ofi:ergy RESL* 1955 Fremont Ave. MS4149
- Idaho Falls. ID 8341 Laboratory Results For MAPEP Series 21 (pBRFO I) NASA Phun Brook Reactor Facility Lab 6100 Cohunbus Ave Sandusky. OH 44870
\\I.\\PLP 09 \\laS:!I : R<l cliologiral, illorganir a1ul willi,olalik orgallir\\ romhillt'cl,oil,Iallllani Ref Bias Acceptance Une Unc Anal}:!e Result Value Flag Notes
(%)
Range Value Flag Amerlclum-241 91.17 89.8 A
1.5 62.9-116.7 1.28 L
Ceslum-134 NR Cestum-137 687.5 669 A
2.8 468-870 9.33 L
COO8Jt-57 621.7 586 A
6.1 410-762 9.08 L
Cobalt~
328.0 327 A
0.3 229-425 4.52 L
Iron-55 NR 796 557 -1035 Manganese-54 NR 796 557 -1035 Nickel-63 NR 680 476-884 Plutonlum-238 NR 63.2 442-82.2 Plutonlum-239/240 NR 116.3 81.4-151.2 Potasslum-40 NR 375 263-488 Strontlum-90 NR 455 319*592 Technetlum-99 NR 444 311-577 Uranlum-234/233 NR 209 146-272 Uranlum-238 NR 217 152-282 Zlnc-65 NR 1178 825-1531 Radiological Reference Date: JII~l ' 1, ]009
\\I.\\PEP 09 \\1<1\\\\ 21 : Radiolugiral. illUrgallir fOIllilillr/l \\'all'\\ 'Iiludanl Ref Bias Acceptance Une Unc Analyte Result Value Flag Notes
(%)
Range Value Flag Amerlclum-241 1.18 1.04 A
13.5 0.73-1.35 0.19 Ceslum-134 NR 32.2 22.5-41.9 Ceslum-137 41.3 41.2 A
0.2 28.8-53.6 0.65 L
CObalt-57 40.3 36.6 A
10.1 25.6-47.S 0.61 L
Cobalt-60 15.3 15.4 A
-0.6 10.8-20.0 0.26 L
Hydrogen-3 NR 634.1 443.9 - 824.3 Iron-55 NR 60.8 42.6-79.0 Manganese-54 NR Nlckel-63 NR 44.2 30.9-57.5 Plutonlum-238 NR 0.018 Plutonlum-239/240 NR 1.64 1.15-2.13 Strontlum-90 NR 12.99 9.09-16.89 Technetlum-99 NR 10.0 7.0-13.0 Uranlum-234/233 NR 2.96 2.07-3.85 Uranlum-238 NR 3.03 2.12-3.94 Zlnc-65 NR 26.9 18.8-35.0 RadiolOgical Reference Date: JIIIl' 1, ]009 49
[)
o o
o o
o II
~
o o
o o
o EP Mixed AnaJyte Performance Evaluation Program DcplU1ment ofEllergy RESL - 1955 Fremont Aye. MS4J49 - Idaho Falls. ID 8341 Laboratory Results For MAPEP Series 21 (pBRFO I) NASA Phun Brook Reactor Facility Lab 6100 Cohunbus Ave Sandusky. OH 44870
\\I.\\I'EP 09 \\laS:!I: R;j(liological. illorgallir alltl Willi \\olalik orgallir, cOlllhillt*tl,oil '1<llIdanl Radllllll!llcal C:lllh. I Hq I\\:l! I Ref Bias Acceptance Unc Unc Anal}:!e Result Value Flag Notes (0/0)
Range Value Flag Amerlclum-241 91.17 89.8 A
1.5 62.9-116.7 1.28 L
Ceslum-134 NR Ceslum-137 687.5 669 A
2.8 468-870 9.33 L
Cobalt-57 621.7 586 A
6.1 410-762 9.08 L
Cobalt-60 328.0 327 A
0.3 229-425 4.52 L
Iron-55 NR 796 557 - 1035 Manganese-54 NR 796 557 -1035 Nickel-63 NR 680 476-884 Plutonlum-238 NR 63.2 442-82.2 Plutonlum-239/240 NR 116.3 81.4-151.2 Potasslum-40 NR 375 263-488 Strontlum-90 NR 455 319-592 TechnetJum-99 NR 444 311-577 Uranlum-234/233 NR 209 146-272 Uranlum-238 NR 217 152-282 Zlnc-65 NR 1178 825-1531 Radiological Reference Date: JII~V 1, ]009
\\I.\\PEP 09 \\1<1\\\\ ~I: i{adiologic<l1. illllrg'lllir fOlllhitt<'11 \\\\all'l.. Ianrlanl Radlo\\np:lCa\\
1:1111'. (Aq L I Ref Bias Acceptance Unc Unc Analyte Result Value Flag Notes (0/0)
Range Value Flag Amerlclum-241 1.18 1.04 A
13.5 0.73-1.35 0.19 Ceslum-134 NR 32.2 22.5-41.9 Ceslum-137 41.3 41.2 A
0.2 28.8-53.6 0.65 L
CObalt-57 40.3 36.6 A
10.1 25.6-47.6 0.61 L
Cobalt-60 15.3 15.4 A
-0.6 10.8-20.0 0.26 L
Hydrogen-3 NR 634.1 443.9 - 824.3 Iron-55 NR 60.8 42.6-79.0 Manganese-54 NR Nlckel-63 NR 44.2 30.9-57.5 Plutonlum-238 NR 0.018 Plutonlum-239/240 NR 1.64 1.15-2.13 Strontlum-90 NR 12.99 9.09-16.89 Technetlum-99 NR 10.0 7.0-13.0 Uranlum-234/233 NR 2.96 2.07-3.85 Uranlum-238 NR 3.03 2.12-3.94 Zinc-65 NR 26.9 18.8-35.0 RadiolOgical Reference Dare: Jill.. 1, ]009 49
\\I.\\PEP 119 R(IL! I: R:\\(liol()~iral ail mit'!'
RadlOlo!:!lCa l LIII h : IBq ~alllp ki Ref Bias Acceptance Unc Unc Analy!e Result Value Flag Notes
(%}
Ran~e Value Flag Amer1clum-241 NR Ceslum-134 NR Ceslum-137 1.66 1.40 A
18.6 0.98-1.82 0.10 Coban-57 7.08 6.48 A
9.3 4.54-8.42 0.13 L
Cobalt-60 1.34 30.1 0.72-1.34 0.08 Manganese-54 NR 5.49 3.84-7.14 Plutonlum-238 NR 0.091 0.064-0.118 Plutonlum-239/240 NR 0.138 0.097 - 0.179 Strontium-90 NR 0.835 0.585 - 1.086 Uranlum-234/233 NR 0.300 0.210-0.390 Uranlum-238 NR 0.312 0.218-0.406 Zlnc-65 NR 3.93 2.75-5.11 Radiological Reference Date: JII~l' 1, 2009 o
o o
o o
50 o
\\!.\\PEP 119 1~(IF21: R:uliolngiral ail mil'!'
Ref Bias Acceptance Unc Unc Analy!e Result Value Flag Notes
(%}
Range Value Flag Amerklum-241 NR Ceslum-134 NR Ceslum-137 1.66 1.40 A
18.6 0.98-1.82 0.10 Coban-57 7.08 6.48 A
9.3 4.54-8.42 0.13 L
Coball-60 1.34 30.1 0.72-1.34 0.08 Manganese-54 NR 5.49 3.84-7.14 Plulonlum-238 NR 0.091 0.064-0.118 Plutonlum-239/240 NR 0.138 0.097 - 0.179 Strontium-90 NR 0.835 0.585 - 1.086 Uranlum-234/233 NR 0.300 0.210-0.390 Uranlum-238 NR 0.312 0.218-0.406 Zlnc-65 NR 3.93 2.75-5.11 Radiological Reference Date: JII~l' 1, 2009 o
o o
o o
o 50
01 i Ecker,. Ziegler Analytics 1380 Seaboard Industrial Blvd.
Atlanta. Georgia 30318 - US.A.
Tel 404-352-8677 Fax 404-352-2837
~~
RESULTS OF ENVIRONMENTAL CROSS CHECK PROGRAM NASA Plum Brook Reactor Facility First Quarter 2009 (Ref. Date 03-19-2009) 1fI'I ~
.5-11-1)'
DaIdeI M. Montgomery, QA Manager
_F_""".
i Ecker,- Ziegler Analytics 1380 Seaboard Industrial Blvd.
Atlanta. Georgia 30318 - US.A.
Tel 404-352-8677 Fax 404-352-2837 RESULTS OF ENVIRONMENTAL CROSS CHECK PROGRAM NASA Plum Brook Reactor Facility First Quarter 2009 (Ref. Date 03-19-2009)
SAMPLE ANALYSIS NASAPBRF UNCERTAINTY EM UNCERTAINTY RATIO VALUE (2 Slama)
VALUE (I Sigma)
NASAPBRF:
EZA
£6598-792 H-3 4.42E+G3 pCiIL 1.20E+G3 4.48E+G3 pCiIL 7.48E+GI 0.99 H-3 Water Rj Plnt Quamr 2819 OW. Date 03-D-lOOJ)
SAMPLE ANALYSIS NASAPBRF VALUE UNCERTAINTY (2 Slama)
EM VALUE UNCERTAINTY (I Sigma)
RATIO NASAPBRF:
EZA
£6598-792 H-3 4.42E+G3 pCiIL I.lOE+G3 4.48E+G3 pCiIL 7.48E+GI 0.99 H-3 Water
a Eckert & Ziegler
- Analytlcs 1380 Seaboard Industrial Blvd.
Atlanta, Georgia 30318 - U.S.A.
Tel 404'352-8677 Fax 404'352-2837 CJ1 W
RESULTS OF ENVIRONMENTAL CROSS CHECK PROGRAM NASA Plum Brook Reactor Facility Third Quarter 2009 (Ref. Date 09-17-2009) m~ /I-,,-,!
Daniel M:OntgOiDery, QA. Manager
_F___.
CJ1 W
I Eckert & Ziegler Analytlcs 1380 Seaboard Industrial Blvd.
Atlanta, Georgia 30318 - U.S.A.
Tel 404'352-8677 Fax 404'352-2837
_F ___.-
RESULTS OF ENVIRONMENTAL CROSS CHECK PROGRAM NASA Plum Brook Reactor Facility Third Quarter 2009 (Ref. Date 09-17-2009)
SAMPLE ANALYSIS NASAPBRF UNCERTAINTY EZA UNCERTAINTY RATIO VALUE (1 Sigma)
VALUE (1 Sigma)
NASAPBRF:
EZA E6902-792 B-3 1.30E+04 pCi/L 8.25E+02 1.41E+04 pCi/L 2.3SE+02 0.93 B-3 Water
~
ThIrd Qu.ur 2009 (Ref. Date 09-17-2009)
SAMPLE ANALYSIS NASAPBRF VALUE UNCERTAINTY (1 Sigma)
EZA VALUE UNCERTAINTY (1 Sigma)
RATIO NASAPBRF:
EZA E6902-792 B-3 1.30E+04 pCi/L 8.25E+02 1.41E+04 pCi/L 2.3SE+02 0.93 B-3 Water ThIrd Qu.ur 2009 (Ref. Date 09-17-2009)