Ninety Day (Post-Outage) Response to NRC Generic Letter 2008-01
ML101620579
Person / Time
Site: Hatch Southern Nuclear icon.png
Issue date: 06/11/2010
From: Ajluni M
Southern Nuclear Operating Co
To:
Document Control Desk, Office of Nuclear Reactor Regulation
References
GL-08-001, NL-10-0858
Download: ML101620579 (15)


Text

Southern Nuclear Operatin!l Company, Inc.

rei 205 SOUTHERN'\\'

June 11, 2010 COMPANY Docket Nos.: 50-321 NL-10-0858 U. S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, D. C. 20555-0001 Edwin I. Hatch Nuclear Plant-Unit 1 Ninety Day (Post-Outage) Response to NRC Generic Letter 2008-01

References:

1.

NRC Generic Letter 2008-01, "Managing Gas Accumulation in Emergency Core Cooling, Decay Heat Removal, and Containment Spray Systems" dated January 11, 2008.

2.

Request for Extension of the Three-Month Response to NRC Generic Letter 2008-01, "Managing Gas Accumulation in Emergency Core Cooling, Decay Heat Removal, and Containment Spray Systems" dated April 8, 2008.

3.

Three-Month Response to NRC Generic Letter 2008-01, "Managing Gas Accumulation in Emergency Core Cooling, Decay Heat Removal, and Containment Spray Systems" dated May 30,2008.

4.

NRC Letter to Dennis Madison concerning Response to Extension Request dated June 16, 2008 (TAC Nos. MD7833 and MD7834).

5.

NRC Letter to Nuclear Energy Institute, dated July 8,2008 (ML081830557).

6.

Nine-Month Response to NRC Generic Letter 2008-01, "Managing Gas Accumulation in Emergency Core Cooling, Decay Heat Removal, and Containment Spray Systems" dated October 10, 2008.

U.S. Nuclear Regulatory Commission NL*10*0858 Page 2

7.

Nine*Month Supplemental (Post*Outage) Response to NRC Generic letter 2008*01, dated 8/24/2009.

8.

NRC request for Additional Information Regarding Generic letter 2008*01, "Managing Gas Accumulation in Emergency Core Cooling Decay heat Removal, and Containment Spray Systems" (TAC Nos MD7833 and MD7834) dated November 5, 2009.

9.

Response to NRC Generic Letter 2008*01, Response to Requests for Additional Information, dated December 14, 2009 Ladies and Gentlemen:

The Nuclear Regulatory Commission (NRC) issued Generic Letter (GL) 2008*01 (Reference 1) to request that each licensee evaluate the licensing basis, design, testing, and corrective actions for the emergency core cooling, decay heat removal, and containment spray systems to ensure that gas accumulation is maintained less than the amount that challenges operability of these systems, and that appropriate action is taken when conditions adverse to quality are identified. is the Southern Nuclear Operating Company (SNC) supplemental response to the nine*month response letter. This supplemental response is being submitted within ninety days following the completion of the Edwin I. Hatch Nuclear Plant (HNP) Unit 1 refueling outage 1 R24 (March 2010).

In summary, SNC has concluded that the subject systems at HNP are operable and that HNP is currently in compliance with the licensing basis documentation and applicable regulations, including 10 CFR 50 Appendix B, Criteria III, V, XI, XVI, and XVII, with respect to the concerns outlined in GL 2008*01 regarding managing gas accumulation in these systems/functions.

This letter contains no new NRC commitments. It does repeat the commitment made in the RAI response of December 14,2009 to submit a Technical Specification change within one year after the NRC issues an approved TSTF.

If you have any questions, please contact Mr. N. J. Stringfellow at 205*992*7037

U.S. Nuclear Regulatory Commission NL-10-0858 Page 3 Mr. M. J. Ajluni states he is Nuclear Licensing Manager of Southern Nuclear Operating Company, is authorized to execute this oath on behalf of Southern Nuclear Operating Company and to the best of his knowledge and belief, the facts set forth in this letter are true.

Respectfully submitted, M. J. Ajluni Manager, Nuclear Licensing n to and subscribed before me this / It!.> day of Jl&O...e.

,2010.

My commission expires: 7-:J../,.,s201 OJ...

MJAlPAH/lac

Enclosures:

1. HNP Unit 1 Ninety Day Post-Outage Response to NRC Generic Letter 2008-01
2. Commitment Table Southern Nuclear Operating Company Mr. J. T. Gasser, Executive Vice President Mr. D. R. Madison, Vice President - Hatch Ms. P. M. Marino, Vice President - Engineering RTYPE: CHA02.004 U. S. Nuclear Regulatory Commission Mr. L. A Reyes, Regional Administrator Mr. R. E. Martin, NRR Project Manager - Hatch Mr. E.D. Morris, Senior Resident Inspector - Hatch Mr. P.G. Boyle, NRR Project Manager State of Georgia Mr. C. Clark, Commissioner-Department of Natural Resources

Edwin I. Hatch Nuclear Plant Supplemental Response to Nuclear Regulatory Commission Generic Letter 2008-01 HNP Unit 1 Ninety Day Post-Outage Response to NRC Generic Letter 2008-01 HNP Unit 1 Ninety Day Post-Outage Response to NRC Generic Letter 2008-01 This enclosure provides the ninety day Post-Outage Response to Generic Letter (GL) 2008-01, as requested by Nuclear Regulatory Commission (NRC) letter dated June 16, 2008 for actions that were deferred until the next refueling outage for Edwin I. Hatch Nuclear Plant (HNP)-Unit 1.

The following information is provided in this enclosure:

  • A description of the results of evaluations that were performed pursuant to GL 2008-01 on the previously incomplete activities, such as system piping walkdowns, HNP Unit 1 (see section A of this enclosure).
  • A description of any additional corrective actions determined necessary to assure system operability and compliance with the quality assurance criteria in Sections III, V, XI, XVI, and XVII of Appendix B to 10 CFR Part 50 and the licensing basis and operating license with respect to the subject systems, including a schedule and a basis for that schedule (see section B.1 of this enclosure), and summary of any changes or updates to previous corrective actions, including any schedule change and the basis for the change. (See section B.2 of this enclosure).
  • Also included is additional information concerning activities that have occurred on HNP-Unit 2.

The original conclusions documented in the nine-month response have not changed; i.e., that the licensing basis, design, testing, and corrective action evaluations, and the corrective actions resulting from these evaluations performed in response to GL 2008-01 provide reasonable assurance that the HNP Emergency Core Cooling (ECCS) and Residual Heat Removal (RHR) systems will continue to perform their required safety functions. It should be noted that containment spray is an operating mode of the RHR system. In addition, the Reactor Core Isolation Cooling (RCIC) system was also evaluated.

The remaining sections in the enclosure primarily discusses the results of design evaluation reviews conducted during the recent HNP Unit 1 refueling outage (1 R24, March 2010) associated with previously uncompleted walkdown activities.

E1-1 HNP Unit 1 Ninety Day Post-Outage Response to NRC Generic Letter 2008-01 A. EVALUATION RESULTS

1. Design Basis Documents There have been no changes to the design basis documents such as the FSAR.

However, drawings and procedures have been revised to reflect the addition of the vent valves in the various Unit 1 locations.

2. Confirmatory Walkdowns
a. Piping elevations of accessible piping were evaluated using laser scanning methodology. The evaluation of the laser scanning results has been completed.

The results were incorporated into plant procedures by October 13, 2009.

The confirmatory walkdowns of the remaining sections of Unit 1 system piping were completed during 1 R24. The walkdowns included confirmation of vent valve location and orientation. No significant issues and no additional required modifications were identified

b. The following is a summary of the results of venting utilized to ensure that voids in the identified high points were confirmed acceptable:

Prior to the Spring 2010 Unit 1 refueling outage, all critical locations in the Unit 1 HPCI, RCIC, RHR, and Core Spray suction piping were inspected for voids via ultrasonic testing (UT). One void was discovered and was evaluated to be within the acceptance criteria. UT inspections were also performed on certain locations in the discharge piping of these systems, with no voids found that were greater than the established acceptance criteria.

Vent valves were added in several locations to HNP-Unit 1 during the 1 R24 refueling outage. During the Unit 1 refueling outage, all critical locations on the Unit 1 HPCI, RCIC, RHR, and Core Spray systems were vented prior to plant startup. Successful venting is defined by having no voids larger than the acceptance criteria and confirmation of no voids by UT. Also, voids could be removed by system flushing.

During the 1 R24 outage UT inspections, gas voids were found in the condensate transfer supply piping to the Unit 1 "A" and "B" Core Spray systems piping upstream of the injection valve 1E21-F004A1B. The void volumes were quantified in each case and determined to be acceptable.

E1-2 HNP Unit 1 Ninety Day Post-Outage Response to NRC Generic Letter 2008-01

3. Vent Valves Vent valves were installed at seven locations on Unit 1 during the 1 R24 outage.
  • A venting location was installed on the discharge line of the RHR A system.
  • A venting location was installed on the discharge line of the RHR B system.
  • A venting location was installed on the RHR Fuel Pool Cooling Assist suction line.
  • A venting location was installed on the HPCI system suction line from the Suppression Chamber.
  • A venting location was installed on the RCIC system condensate pump discharge line.
  • A venting location was installed on the Core Spray A injection line.
  • A venting location was installed on the Core Spray B injection line.

Installation of additional vent valves will be evaluated based on the results of ongoing system monitoring.

4. Procedures Since the SNC Nine-Month Response letter dated October 10, 2008, the following HNP procedures were established to implement monitoring and trending of gas accumulation for the suction and discharge piping of the RHR, Core Spray, HPCI and RCIC systems.

42EN-MON-001-0, "Monitoring and Trending of Gas Accumulation in Safety Injection System."

NMP-ES-024-515, "Ultrasonic Examination Procedure for Liquid Level Measurement. "

The Unit 1 and Unit 2 RHR, CS, HPCI, and RCIC system operating and venting procedures were also revised to incorporate utilization of added vent valves, improved venting practices, and information related to gas accumulation.

E1-3 HNP Unit 1 Ninety Day Post-Outage Response to NRC Generic Letter 2008-01 B. DESCRIPTION AND SCHEDULE OF CORRECTIVE ACTIONS

1. Corrective Actions Completed
a. A generic guidance document for fill and vent was implemented. Subsequently, the information has been incorporated into the applicable ECCS pump operating and surveillance procedure.
2. Corrective Actions to be Completed, Schedule, and Basis for that Schedule The corrective actions to be completed and schedules are:
a. A Corrective Action for procedure development/revision has been initiated to include requirements for periodic monitoring and trending of ECCS, RHR, and RCIC piping. This action will be complete by November 21, 2008.

Status:

Procedure 42EN-MON-001-0, "Monitoring and Trending of Gas Accumulation in Safety Injection Systems" was created, and monitoring was implemented for each unit. The procedure contains the overall gas voiding guidance. It contains specific acceptance criteria for monitored locations and overall acceptance criteria limits. The procedure lists locations that are monitored using ultrasonic measurements and includes the frequency for monitoring and guidance for ultrasonic monitoring performed by engineering personnel. The procedure also lists locations that are monitored by performance of routine venting by Operations. The procedure was implemented on November 19, 2008.

This Corrective Action for HNP Unit 1 and Unit 2 is complete.

b. Corrective Action has been initiated to revise HNP procedures to provide assurance that gas in the affected systems suction piping is limited to within the acceptance criteria determined by the HNP specific analyses. Specifically, HPCI System post maintenance fill and vent procedures used to provide assurance that gas in the HPCI System suction piping is limited to within the acceptance criteria (including the impact of gas trapped in valve bonnets) will be revised based on the HNP specific analyses.

Procedural guidance will be provided by November 21, 2008.

E1-4 HNP Unit 1 Ninety Day Post-Outage Response to NRC Generic Letter 2008-01 Status:

Procedure 42EN-MON-001-0, "Monitoring and Trending of Gas Accumulation in Safety Injection Systems" has been implemented for each unit. The procedure provides guidance for identifying and evaluating the presence of voiding in critical system piping. It contains specific acceptance criteria for monitored locations and overall acceptance criteria limits within the HPCI system suction piping. The procedure lists locations that are monitored, using ultrasonic monitoring for gas voids and lists locations that are monitored by performance of routine venting by Operations. The procedure also includes the frequency for monitoring guidance for ultrasonic monitoring performed by engineering personnel and includes those locations that are flushed/dynamically vented and the flushing/dynamic venting frequency. The procedure was implemented on November 19, 2008.

The procedure, 34S0-E41-001-2, "High Pressure Coolant Injection (HPCI)

System" used for filling and venting the HPCI system following post maintenance activities was reviewed. It was confirmed that this procedure when used in conjunction with 42EN-MON-001-0 above provided assurance that void in the HPCI suction piping will be limited to the acceptance criteria determined from HNP specific analysis.

This Corrective Action for HNP Unit 1 and Unit 2 is complete.

c. A Corrective Action has been initiated to perform analyses, similar to the analysis performed for the HPCI System, to determine the pump suction acceptance criteria for the following HNP systems: RCIC, LPCI mode of RHR System operation, and CS. HNP post maintenance fill and vent procedures will be revised to provide assurance that gas in the affected systems suction piping is limited to within the acceptance criteria (including the impact of gas trapped in valve bonnets) determined by the HNP specific analyses.

The affected procedures will be revised within one hundred and twenty (120) days following receipt of the analyses results. Final corrective action will be discussed in our follow-up letter.

Status:

The analysis to determine the pump suction acceptance criteria for RCIC, the modes of RHR (including LPCI and Containment Spray), and Core Spray has been completed.

Procedure 42EN-MON-001-0, "Monitoring and Trending of Gas Accumulation in Safety Injection Systems" has been implemented for each unit. The procedure provides guidance for identifying and evaluating the presence of voiding in critical system piping. It contains specific acceptance criteria for monitored locations E1-5 HNP Unit 1 Ninety Day Post-Outage Response to NRC Generic Letter 2008-01 and overall acceptance criteria limits. The procedure lists locations that are monitored, using ultrasonic monitoring, for gas voids, and lists locations that are monitored by performance of routine venting by Operations. The procedure also includes the frequency for monitoring and guidance for ultrasonic monitoring performed by engineering personnel and includes those locations that are flushed/dynamically vented and the flushing/dynamic venting frequency. The procedure was implemented on November 19, 2008.

This Corrective Action for HNP Unit 1 and Unit 2 is complete.

d. A Corrective Action has been initiated to implement the Joint Owners Group methodology for evaluating pump discharge piping susceptible to pressure pulsation after pump start and to develop HNP specific acceptance criteria for discharge piping gas voids. HNP procedures will be revised to provide assurance that gas in the affected systems discharge piping is limited to within the acceptance criteria determined by the HNP specific application of the Joint Owner's Group program method. Air trapped in valve bonnets that could get in the discharge piping of the subject systems will be accounted for in the pump discharge void acceptance criteria established for HNP.

The affected procedures will be revised within one hundred and twenty (120) days following receipt of the above results. Final corrective action will be discussed in our follow-up letter.

Status:

The ECCS, RHR, and RCIC pump discharge piping were evaluated to determine the potential for a significant water hammer event resulting from a void present in the system during a pump start. The evaluations provide an assessment of the maximum pressures that could result from both pump starts due to a receipt of an accident Signal, as well as during pump surveillance testing. This information was used to determine the maximum gas volume that can be accumulated within the piping high pOints to prevent challenging the system relief valves and confirm the load on the piping system remains within the design of the piping restraints.

The assessment of the relief valves is a function of the total gas volume in the system and therefore is system related. The evaluation for the piping loads is typically governed by the gas volume that could be accumulated in the highpoint with the largest volume. In this regard, a bounding (system related) criterion was determined. Selected highpoints will be monitored to provide reasonable assurance that the total gas volume is less than the system related criterion.

The gas that could be collected in check valves was included in the total gas system volume (discussed above). The gas volumes that are collected in the bonnets of globe and gate valves were not included since they do not actively E1-6 HNP Unit 1 Ninety Day Post-Outage Response to NRC Generic Letter 2008-01 participate in the fluid stream and act as local surge suppressors that reduce the waterhammer impulse and therefore the piping loads.

The acceptance criteria for the discharge piping was incorporated into the HNP procedure 42EN-MON-001-0, "Monitoring and Trending of Gas Accumulation in Safety Injection System" on August 21,2009.

This Corrective Action for HNP Unit 1 and Unit 2 is complete.

e. Based on the identification of the locations where gas can accumulate, and the gas intrusion mechanisms identified above, it was determined that currently no new vent valves should be installed in Unit 1 and that new vent valves should be installed at two (2) locations in Unit 2, and other locations in both units will be evaluated further to determine whether new vent valves should be added, or if these locations should be monitored.

The new Unit 2 vent valves will be installed by the end of the Spring 2009 refueling outage (2R20, May 2009).

Status:

Vent valves were installed at several locations on Unit 1 during the 1 R24 outage.

  • A venting location was installed on the discharge line of the RHR A system.
  • A venting location was installed on the discharge line of the RHR B system.
  • A venting location was installed on the RHR Fuel Pool Cooling Assist suction line.
  • A venting location was installed on the HPCI system suction line from the Suppression Chamber.
  • A venting location was installed on the RCIC system condensate pump discharge line.
  • A venting location was installed on the Core Spray A injection line.
  • A venting location was installed on the Core Spray B injection line.

Unit 2 vent valve installation has been completed.

f. The evaluation of the other locations to determine if vent valves need to be installed or jf these locations should be monitored will be completed by 120 days after the receipt of the engineering evaluation. Final corrective action will be discussed in our follow-up letter.

E1-7 HNP Unit 1 Ninety Day Post-Outage Response to NRC Generic Letter 2008-01 Status:

The review of the information contained in the engineering evaluation has been completed. No additional vent valve installation will be required. Additional monitoring locations identified by the evaluation were incorporated into the applicable procedures by October 13, 2009.

This Corrective Action for HNP Unit 1 and Unit 2 is complete. The procedure revision encompasses HNP Units 1 and 2.

g. The Unit 2 inaccessible piping will be walked down during the Spring 2009 refueling outage.

Status:

Unit 2 walkdowns were completed during outage 2R20.

This Corrective Action for HNP Unit 2 is complete.

h. The walkdown results for the Unit 2 Spring 2009 outage will be evaluated and necessary modifications will be completed by the end of the refueling outage.

Status:

The walkdown results for inaccessible locations have been evaluated. No significant issues were identified and no additional modifications were identified.

This Corrective Action for HNP Unit 2 is complete.

i. The Unit 1 inaccessible piping will be walked down during the Spring 2010 refueling outage.

Status:

Unit 1 walkdowns were completed during outage the Unit 1 Spring 2010 refueling outage (1 R24).

j. The walkdown results for the Unit 1 Spring 2010 outage will be evaluated and necessary modifications will be completed by the end of the refueling outage.

Status:

The walkdown results for inaccessible locations have been evaluated. No significant issues were identified and no additional modifications were identified.

E1-8 HNP Unit 1 Ninety Day Post-Outage Response to NRC Generic Letter 2008-01 This Corrective Action for HNP Unit 1 is complete.

k. A Corrective Action for potential procedure revisions was initiated to evaluate the comments resulting from the operating procedure review. The Corrective Action will require reviewing the comments to determine the scope of the necessary procedure revisions.

This Corrective Action will be completed by June 30,2009.

Status:

This correction action to review the comments and to implement applicable procedure revisions has been completed.

This Corrective Action for HNP Unit 1 and Unit 2 is complete.

Conclusion SNC has evaluated the applicable systems at HNP Unit 1 that perform the functions described in the generic letter and has concluded that these systems are operable.

As previously reported, all Unit 2 systems remain operable.

E1-9

Edwin I. Hatch Nuclear Plant Supplemental Response to Nuclear Regulatory Commission Generic Letter 2008-01 Commitment Table Commitment Table Type Scheduled I

Commitment for HNP Unit 1 One-Time Continuing Completion Date I Action Compliance SNC will either submit a technical I

submit a plant-specific technical Within 1-year after X

specification change within a year after NRC Issuance the issuance of an NRC approved TSTF concerning gas accumulation.

specification based on the TSTF or E2-1