U-603955, Core Operating Limits Report, Cycle 13

From kanterella
(Redirected from ML101230239)
Jump to navigation Jump to search
Core Operating Limits Report, Cycle 13
ML101230239
Person / Time
Site: Clinton Constellation icon.png
Issue date: 04/19/2010
From: Kemper D
Exelon Generation Co, Exelon Nuclear
To:
Document Control Desk, Office of Nuclear Reactor Regulation
References
U-603955
Download: ML101230239 (56)


Text

PROPRIETARY INFORMATION WITHHOLD FROM PUBLIC DISCLOSURE UNDER 10 CFR 2.390(A)(4)

WHEN SEPARATED FROM ATTACHMENT, COVER LETTER IS DECONTROLLED.

Exel n.

Nuclear Clinton Power Station 8401 Power Road Clinton, IL 61727 U-603955 10 CFR 50.36 April 19, 2010 U.S. Nuclear Regulatory Commission Attention: Document Control Desk Washington DC 20555 Clinton Power Station, Unit 1 Facility Operating License No. NPF-62 NRC Docket No. 50-461

Subject:

Core Operating Limits Report for Clinton Power Station, Unit 1, Cycle 13

Reference:

Letter U-603942 dated January 29, 2010 from F. A. Kearney (Exelon Generation Company) to NRC Document Control Desk, "Issuance of the Core Operating Limits Report for Clinton Power Station, Unit 1, Cycle 13" In the referenced letter, Exelon Generation Company (EGC) submitted, in accordance with TechnicalSpeCification 5.6.5, "Core Operating Limits Report (COLR)," Item d., the COLR for Clinton Power Station, Unit 1, Cycle 13. As stated in the letter, Attachment 1 contains a proprietary version of the COLR that was requested to be withheld from public disclosure under 10 CFR 2.390(a)(4)., and Attachment 2 contains a non-proprietary version of the COLR.

Please replace the cover letter submitted previously with this cover letter.

If you have any questions concerning this letter, please contact me at (217) 937-2800.

Respectfully, 0.pe. J. r * , .. .*  :

Regulatory Assurance Manager Clinton Power Station PROPRIETARY INFORMATION WITHHOLD FROM PUBLIC DISCLOSURE UNDER 10 CFR 2.390(A)(4)

WHEN SEPARATED FROM ATTACHMENT, COVER LETTER IS DECONTROLLED.

. -, "k,,

PROPRIETARY INFORMATION WITHHOLD FROM PUBLIC DISCLOSURE UNDER 10 CFR 2.390(A)(4)

WHEN SEPARATED FROM ATTACHMENT, COVER LETTER IS DECONTROLLED.

U. S. Nuclear Regulatory Commission April 19, 2010 Page 2 JLP/blf cc: Regional Administrator, NRC Region III NRC Senior Resident Inspector, Clinton Power Station PROPRIETARY INFORMATION WITHHOLD FROM PUBLIC DISCLOSURE UNDER 10 CFR 2.390(A)(4)

WHEN SEPARATED FROM ATTACHMENT, COVER LETTER IS DECONTROLLED.

Attachment 2 Clinton Power Station, Unit 1, Cycle 13, Core Operating Limits Report, Non-Proprietary Version

Exei0 Nudw - MNudM Fuel DOC IM COLR Cfto I Rev. 4 CLICIS Cam Opor"Luaftu Repat AvMmdglbwMCFR1M CORE OPERATING UMITS REPORT FOR CUNTON POWER STATION UNIT I CYCLE 13 Prepared By:ý,e 1 ,,A DOW R-iswG o W. B" o,,, ?l9ILL)

RE Red e --

Reviewed By:

(ameBY Apv Date: /-4&5 J. Tuhi Station Qualified Reviewer By: Date::.~ if Page I of 53

Exelon Nuclear - Nuclear Fuels DOC ID: COLR Clinton 1 Rev. 4 CLLC13 Core Operating Limits Report Non-Proprietary Information Submitted in Accordance with 10 CFR 2.390 Table of Contents Page 1.0 Terms and Definitions 4 2.0 General Information 5 3.0 MAPLHGR Limits 6 4.0 MCPR Limits 7 5.0 Linear Heat Generation Rate Limits 11 6.0 Reactor Protection System (RPS) Instrumentation 14 7.0 Stability Protection Setpoints 14 8.0 Modes of Operation 15 9.0 Methodology 15 10.0 References 16 Appendix A 17 Page 2 of 53

Exelon Nuclear - Nuclear Fuels DOC ID: COLR Clinton 1 Rev. 4 CLLC13 Core Operating Limits Report Non-Proprietary Information Submitted in Accordance with 10 CFR 2.390 List of Tables Page Table 3-1 MAPLHGR for All Fuel Types 6 Table 3-2 MAPLHGR Single Loop Operation (SLO) Multiplier 6 Table 4-1 Operating Limit Minimum Critical Power Ratio 9 Table 4-2 Power Dependent MCPR Limits MCPR(P) and Multipliers K(P) 9 Table 4-3 Flow Dependent MCPR Limits MCPR(F) 10 Table 4-4 Single Loop Operation (SLO) Flow Dependent MCPR Limits MCPR(F) 10 Table 5-1 Linear Heat Generation Rate Limits for U0 2 Rods 11 Table 5-2 Linear Heat Generation Rate Limits for Gad Rods 12 Table 5-3 Power Dependent LHGR Multiplier LHGRFAC(P) 12 Table 5-4 Flow Dependent LHGR Multiplier LHGRFAC(F) 12 Table 5-5 LHGR Single Loop Operation (SLO) Reduction Factor 13 Table 5-6 Power Dependent LHGR Multiplier LHGRFAC(P)

(Loss of 'FULL' Feedwater Heating) 13 Table 5-7 Flow Dependent LHGR Multiplier LHGRFAC(F)

(Loss of 'FULL' Feedwater Heating) 13 Table 7-1 OPRM PBDA Trip Setpoints 14 Table 8-1 Modes of Operation 15 Page 3 of 53

Exelon Nuclear - Nuclear Fuels DOC ID: COLR Clinton 1 Rev. 4 CL1C13 Core Operating Limits Report Non-Proprietary Information Submitted in Accordance with 10 CFR 2.390 1.0 Ten ms and Definitions Base Case A case analyzed with two (2) Safety-Relief Valves Out-of-Service (OOS), one (1) ADS valve OOS, and up to a 50°F feedwater temperature reduction (FWTR includes feedwater heater OOS or final feedwater temperature reduction) at any point in the cycle operation in Dual Loop mode (Reference 3).

Coastdown The reactor condition where thermal power gradually decreases due to fuel depletion while the following conditions are met: 1) all operable control rods are fully withdrawn and 2) all cycle extension techniques have been exhausted including FFWTR and ICF.

DLO Dual Reactor Recirculation Loop Operation FFWTR Final Feedwater Temperature Reduction FWHOOS Feedwater Heaters Out of Service ICF Increased Core Flow LHGR Linear Heat Generation Rate LHGRFAC(F) LHGR thermal limit flow dependent adjustments and multipliers LHGRFAC(P) LHGR thermal limit power dependent adjustments and multipliers MAPLHGR Maximum Average Planar Linear Heat Generation Rate MCPR Minimum Critical Power Ratio MCPR(P) MCPR thermal limit power dependent adjustments and multipliers MCPR(F) MCPR thermal limit flow dependent adjustments and multipliers OLMCPR Operating Limit Minimum Critical Power Ratio OPRM Oscillation Power Range Monitor SLMCPR Safety Limit Minimum Critical Power Ratio SLO Single Reactor Recirculation Loop Operation Page 4 of 53

Exelon Nuclear - Nuclear Fuels DOC ID: COLR Clinton 1 Rev. 4 CLLC13 Core Operating Limits Report Non-Proprietary Information Submitted in Accordance with 10 CFR 2.390 2.0 General Information This report is prepared in accordance with Technical Specification 5.6.5 of Reference 1. Power and flow dependent limits and multipliers are listed for various power and flow levels. Linear interpolation is to be used to find intermediate values.

These values have been determined using NRC-approved methodologies presented in Reference 2 and are established such that all applicable limits of the plant safety analysis are met.

The data presented in this report is valid for all licensed operating domains on the operating map, including:

  • Maximum Extended Load Line Limit down to 99% of rated core flow during full power operation
  • Increased Core Flow (ICF) up to 107% of rated core flow
  • Final Feedwater Temperature Reduction (FFWTR) up to 50°F during cycle extension operation

Page 5 of 53

Exelon Nuclear - Nuclear Fuels DOC ID: COLR Clinton I Rev. 4 CLIC13 Core Operating Limits Report Non-Proprietary Information Submitted in Accordance with 10 CFR 2.390 3.0 MAPLHGR Limits 3.1 Technical Specification

Reference:

Sections 3.2.1 and 3.4.1.

3.2

Description:

Table 3-1 is used to determine the maximum average planar linear heat generation rate (MAPLHGR) limit for each fuel type. Limits listed in Table 3-1 are for dual reactor recirculation loop operation (DLO).

For single reactor recirculation loop operation (SLO), the MAPLHGR limits given in Table 3-1 must be multiplied by a SLO MAPLHGR multiplier provided in Table 3-2. The SLO MAPLHGR multiplier for all fuel is 0.76 (Reference 3).

Table 3-1 1 MAPLHGR for All Fuel Types (Reference 3)

Avg. Planar Exposure MAPLHGR Limit (GWd/ST) (kW/ft) 0.00 12.82 14.51 12.82 19.13 12.82 57.61 8.00 63.50 5.00 Table 3-2 MAPLHGR Single Loop Operation (SLO) Multiplier (Reference 3)

Fuel MAPLHGR Type SLO Multiplier All Fuel Types 0.76 I

Linear interpolation should be used for points not listed in Table 3-1.

Page 6 of 53

Exelon Nuclear - Nuclear Fuels DOC ID: COLR Clinton I Rev. 4 CLIC13 Core Operating Limits Report Non-Proprietary Information Submitted in Accordance with 10 CFR 2.390 4.0 MCPR Limits 4.1 Technical Specification

Reference:

Sections 3.2.2 and 3.4.1 4.2

Description:

The various MCPR limits are described below.

4.2.1 Manual Flow Control MCPR Limits The Operating Limit MCPR (OLMCPR) is determined from either section 4.2.1.1 or 4.2.1.2, whichever is greater atany given power and flow condition.

4.2.1.1 Power-Dependent MCPR For operation less than or equal to 33.3% core thermal power, the MCPR(P) as a function of core thermal power is shown in Table 4-2. For operation at greater than 33.3% core thermal power, the OLMCPR as a function of core thermal power is determined by multiplying the applicable rated condition OLMCPR limit shown in Table 4-1 by the applicable MCPR multiplier K(P) given in Table 4-2.

4.2.1.2 Flow-Dependent MCPR Tables 4-3 and 4-4 give the MCPR(F) as a function of flow based on the applicable plant condition. The limits for dual loop operation are listed in Table 4-3. The limits for single loop operation are listed in Table 4-4. The MCPR(F) determined from these tables is the flow dependent OLMCPR.

4.2.2 Automatic Flow Control MCPR Limits Automatic Flow Control MCPR Limits are not provided.

Page 7 of 53

Exelon Nuclear - Nuclear Fuels DOC ID: COLR Clinton I Rev. 4 CLLC13 Core Operating Limits Report Non-Proprietary Information Submitted in Accordance with 10 CFR 2.390 4.2.3 Option A and Option B Option A and Option B refer to use of scram speeds for establishing MCPR operating limits.

Option A scram speed is the BWR/6 Technical Specification scram speed. The Technical Specification scram speeds must be met to utilize the Option A MCPR limits.

Reload analyses performed by GNF for Cycle 13 Option A MCPR limits utilized a 20%

core average insertion time of 0.516 seconds (Reference 12).

To utilize the MCPR limits for the Option B scram speed, the cycle average scram insertion time for 20% insertion must satisfy equation 2 in Reference 5 Section 4. If the cycle average scram insertion time does not meet the Option B criteria, the appropriate MCPR value may be determined from a linear interpolation between the Option A and B limits as specified by equation 4 in Reference 5 Section 4.

4.2.4 Recirculation Flow Control Valve Settings Cycle 13 was analyzed with a maximum core flow runout of 109%; therefore the recirculation flow control valve must be set to maintain core flow less than 109%

(92.105 Mlb/hr) for all runout events (Reference 11).

Page 8 of 53

Exelon Nuclear - Nuclear Fuels DOC ID: COLR Clinton 1 Rev. 4 CLLC13 Core Operating Limits Report Non-Proprietary Information Submitted in Accordance with 10 CFR 2.390 Table 4-1 Operating Limit Minimum Critical Power Ratio (Reference 3)

EQOS GE14C Fuel GE14C Fuel GE141 Fuel GE141 Fuel Combination Option B Option A Option B Option A All exposures All exposures All exposures All exposures Base Case DLO 1.29 1 1.35 1.36 1.42 Base Case SLO 2 1.32 1.38 1.39 1.45 Notes for Table 4-1:

1. Analyzed DLO Option B OLMCPR is 1.27 per Reference 3, value is adjusted to obtain an OPRM amplitude setpoint of 1.10.
2. SLO Option A(B) OLMCPR is the DLO Option A(B) OLMCPR plus 0.03.

Table 4-2 1 Power Dependent MCPR Limits MCPR(P) and Multipliers K(P) ' 2 (References 3 and 7)

SCore Flow Core Thermal Power (%)

Coosino (%of 0 1.61<33.3 >33.3 1 <43 1 >43 1<70 >70 100 Rated) MCPR(P) K(P) 3 Base Case DLO <50 2.20 2.20 1.97 1.351 1.347 1.313 1.212 1.15 1.00 GE14C > 50 2.46 2.46 2.17 Base Case SLO <50 2.23 2.23 2.00 1.351 1.347 1.313 1.212 1.15 1.00 GE14C > 50 2.49 2.49 2.20 Base Case DLO < 50 2.27 2.27 2.04 1.351 1.347 1.313 1.212 1.15 1.00 GE141 > 50 2.53 2.53 2.24 Base Case SLO <50 2.30 2.30 2.07 1.351 1.347 1.313 1.212 1.15 1.00 GE141 > 50 2.56 2.56 2.27 Notes for Table 4-2:

1. Values are interpolated between relevant power levels.
2. Allowable EOOS conditions are listed in Section 8.0.
3. Based on 0.500 second turbine trip time delay with OLMCPR > 1.27.

Page 9 of 53

Exelon Nuclear - Nuclear Fuels DOC ID: COLR Clinton I Rev. 4 CLLC13 Core Operating Limits Report Non-Proprietary Information Submitted in Accordance with 10 CFR 2.390 Table 4-3 Flow Dependent MCPR Limits MCPR(F) 1 (Reference 3)

Core Flow MCPR(F) MCPR(F)

(% rated) GE14C GE141 0.000 1.8819 1.9519 25.000 1.70 1.77 84.100 1.27 -

93.721 - 1.27 109.000 1.27 1.27 Table 4-4 2 Single Loop Operation (SLO) Flow Dependent MCPR Limits MCPR(F)

(Reference 3)

Core Flow MCPR(F) MCPR(F)

(% rated) GE14C GE141 0.000 1.9119 1.9819 25.000 1.73 1.80 84.100 1.30 -

93.721 - 1.30 109.000 1.30 1.30 1

Linear interpolation should be used for points not listed in Table 4-3.

2 Linear interpolation should be used for points not listed in Table 4-4.

Page 10 of 53

Exelon Nuclear - Nuclear Fuels DOC ID: COLR Clinton 1 Rev. 4 CLLC13 Core Operating Limits Report Non-Proprietary Information Submitted in Accordance with 10 CFR 2.390 5.0 Linear Heat Generation Rate Limits 5.1 Technical Specification

Reference:

Section 3.2.3 and 3.4.1.

5.2

Description:

The linear heat generation rate (LHGR) limit is the product of the exposure dependent LHGR limit (from Table 5-1 for U02 fuel rods and Table 5-2 for Gadolinia fuel rods) and the minimum of: the power dependent LHGR Factor, LHGRFAC(P), the flow dependent LHGR Factor, LHGRFAC(F), or the single loop operation (SLO) multiplication factor ifapplicable. The LHGRFAC(P) is determined from Table 5-3. The LHGRFAC(F) is determined from Table 5-4.

The SLO multiplication factor can be found in Table 5-5. Tables 5-1 and 5-2 are the LHGR limit as a function of peak pellet exposure.

The Gadolinia fuel rod limits referenced in Table 5-2 are the most limiting Gadolinia fuel rods.

The most limiting values are provided here as a convenience and do not imply that all the Gadolinia fuel rods must satisfy the listed values.

For Loss of 'FULL' Feedwater Heating (+/-10 *F of design NORMAL temperature), LHGRFAC(P) is determined from Table 5-6 and LHGRFAC(F) is determined from Table 5-7. Concurrent operation with SLO and reduced feedwater heating has not been evaluated and thus is not a valid operating mode. (References 3, 7, 8, 9 and 10)

Table 5-1 Linear Heat Generation Rate Limits for U02 Rods 1 (Reference 4)

Fuel Type LHGR Limit GE14C See Appendix A GE141 See Appendix A Linear interpolation should be used for points not listed in Appendix A.

Page 11 of 53

Exelon Nuclear - Nuclear Fuels DOC ID: COLR Clinton 1 Rev. 4 CLLC13 Core Operating Limits Report Non-Proprietary Information Submitted in Accordance with 10 CFR 2.390 Table 5-2 Linear Heat Generation Rate Limits for Gad Rods 1 (Reference 4)

Fuel Type LHGR Limit GE14C See Appendix A GE141 See Appendix A Table 5-3 2 Power Dependent LHGR Multiplier LHGRFAC(P)

(Reference 3)

C Core Thermal Power (%Rated)

EOOS Combination FlCore 0 21.6 < 33.3 >33.3 100 LHGRFAC(P)

Base Case DLO < 50 0.634 0.634 0.689 0.689 1.000

> 50 0.572 0.572 0.600

< 50 0.634 0.634 0.689 Base Case SLO < 0.689 1.000

> 50 0.572 0.572 0.600 Table 5-4 3 Flow Dependent LHGR Multiplier LHGRFAC(F)

(Reference 3)

Core Flow [ 1

(% rated) LHGFA(F 0.00 0.442 25.00 0.612 30.00 0.646 82.18 1.00 109.00 1.00 1 Linear interpolation should be used for points not listed in Appendix A.

2 Linear interpolation should be used for points not listed in Table 5-3.

Linear interpolation should be used for points not listed in Table 5-4.

Page 12 of 53

Exelon Nuclear - Nuclear Fuels DOC ID: COLR Clinton 1 Rev. 4 CLIC13 Core Operating Limits Report Non-Proprietary Information Submitted in Accordance with 10 CFR 2.390 Table 5-5 LHGR Single Loop Operation (SLO) Reduction Factor (Reference 3)

Fuel LHGR Type SLO Multiplier All Fuel Types 0.76 Table 5-6 Power Dependent LHGR Multiplier LHGRFAC(P)1 (Loss of 'FULL' Feedwater Heating)

(References 3, 8, 9, and 10)

EOOS Core Thermal Power (% Rated)

Combination Core Flow 0 21.6 < 33.3 > 33.3 100 LHGRFAC(P)

< 50 0.627 0.627 0.682 Base Case DLO 0.682 0.99

> 50 n s ,, sr, n .rOq4 Base Case SLO Table 5-7 Flow Dependent LHGR Multiplier LHGRFAC(F)2 (Loss of 'FULL' Feedwater Heating)

(References 3, 8, 9, and 10)

Core Flow LHGRFAC(F)

(% rated) LHGRAC(F 0.00 0.437 25.00 0.605 30.00 0.639 82.18 0.99 109.00 0.99 1 Linear interpolation should be used for points not listed in Table 5-6.

2 Linear interpolation should be used for points not listed in Table 5-7.

Page 13 of 53

Exelon Nuclear - Nuclear Fuels DOC ID: COLR Clinton 1 Rev. 4 CLIC13 Core Operating Limits Report Non-Proprietary Information Submitted in Accordance with 10 CFR 2.390 6.0 Reactor Protection System (RPS) Instrumentation 6.1 Technical Specification

Reference:

Section 3.3.1.1 6.2

Description:

The Average Power Range Monitor (APRM) simulated thermal power time constant, shall be between 5.4 seconds and 6.6 seconds (Reference 12).

7.0 Stability Protection Setpoints The Clinton 1 Cycle 13 OPRM Period Based Detection Algorithm (PBDA) Trip Setpoints for the OPRM System for use in Technical Specification 3.3.1.3 are found in Table 7-1. These values are based on the cycle specific analysis documented in Reference 3.

Any change to the OLMCPR value and/or ARTS-based power dependent MCPR limits should be evaluated for potential impact on the OPRM PBDA Trip Setpoints.

Table 7-1 OPRM PBDA Trip Setpoints (Reference 3)

I Corresponding Maximum Confirmation PBDA Trip Amplitude Count Trip Setting 1.10 13 Page 14 of 53

Exelon Nuclear - Nuclear Fuels DOC ID: COLR Clinton I Rev. 4 CLIC13 Core Operating Limits Report Non-Proprietary Information Submitted in Accordance with 10 CFR 2.390 8.0 Modes of Operation The Allowed Modes of Operation with combinations of Equipment Out-of-Service (EOOS) are as

,described below in Table 8-1:

Table 8-1 Modes of Operation (Reference 3)

Operating Region EOOS Options Standard MELLLA ICF FFWTR 1 Coastdown Base Case DLO, Option A Yes Yes Yes Yes Yes Base Case SLO 1, Option A Yes No No No Yes Base Case DLO, Option B Yes Yes Yes Yes Yes Base Case SLO 1, Option B Yes No No No Yes Notes:

1. Concurrent operation with SLO and Loss of 'FULL' Feedwater Heating (+/-1 0F of design NORMAL temperature) or FFWTR has not been evaluated and thus is not a valid operating mode. (References 3, 8, 9 and 10) 9.0 Methodology The analytical methods used to determine the core operating limits shall be those previously reviewed and approved by the NRC, specifically those described in the following document:
1. "General Electric Standard Application for Reactor Fuel", NEDE-24011-P-A-16, October 2007 and U.S. Supplement NEDE-2401 1-P-A-16-US, October 2007.
2. "BWR Owners' Group Reactor Stability Detect and Suppress Solutions Licensing Basis Methodology and Reload Applications", NEDO-32465, August 1996 Page 15 of 53

Exelon Nuclear - Nuclear Fuels DOC ID: COLR Clinton 1 Rev. 4 CLLC13 Core Operating Limits Report Non-Proprietary Information Submitted in Accordance with 10 CFR 2.390 10.0 References

1. Nuclear Regulatory Commission, Technical Specifications for Clinton Power Station Unit 1, Docket No. 50-461, License No. NPF-62.
2. Global Nuclear Fuel Document, "General Electric Standard Application for Reactor Fuel", NEDE-2401 1-P-A-16, October 2007 and U.S. Supplement NEDE-24011-P-A-16-US, October 2007.
3. Global Nuclear Fuel Document, 0000-0099-4244-SRLR Revision 0, "Supplemental Reload Licensing Report for Clinton Power Station Unit 1 Reload 12 Cycle 13",

December 2009.

4. Global Nuclear Fuel Document, 0000-0099-4244-FBIR-NP Revision 0, "Fuel Bundle Information Report for Clinton Power Station Unit 1 Reload 12 Cycle 13", December 2009.
5. General Electric Document, GE-NE-0000-0000-7456-01P, "Option B Scram Times For Clinton Power Station", February 2002
6. Not used
7. General Electric Document, GE-NE-0000-0042-4570-RO, "Clinton Offrated Analyses Below the PLU Power Level," September 2005.
8. Exelon Design Analysis, GENE-0000-0030-8309, "Engineering Report Clinton Assessment of Feedwater Riser Flow Deviation," Rev. 0, June 14, 2005.
9. Exelon Engineering Change, EC 355034 RO, "Feedwater Riser Flow Deviation Assessment", August 4, 2005
10. Exelon Engineering Change, EC 354185 RO, "Uncertainty in Feedwater Temperature for Two Loop and Single Loop Operation", April 5, 2005
11. Exelon Transmittal of Design Information, TODI NF0900164 Revision 1, "Clinton Unit 1 Cycle 13 FRED Form Revision 1 (APPROVED)", October 30, 2009
12. Exelon Transmittal of Design Information, TODI ES0900019 Revision 0, "Clinton Unit 1 Cycle 13 Resolved OPL-3 Values", October 15, 2009 Page 16 of 53

Exelon Nuclear - Nuclear Fuels DOC ID: COLR Clinton 1 Rev. 4 CLIC13 Core Operating Limits Report Non-Proprietary Information Submitted in Accordance with 10 CFR 2.390 Appendix A Page 17 of 53

Exelon Nuclear - Nuclear Fuels CL1C13 Core Operating Limits Report Non-Proprietary Information submitted in DOC ID: COLR Clinton 1 Rev. 4 Accordance with 10 CFR 2.390 Appendix A Global Nuclear Fuel - Americas AFFIDAVIT I, Anthony P. Reese, state as follows:

(1) I am Manager, Reload Design & Analysis, Global Nuclear Fuel-Americas, LLC ("GNF-A"), and have been delegated the function of reviewing the information described in paragraph (2) which is sought to be withheld, and have been authorized to apply for its withholding.

(2) The information sought to be withheld is contained in the GNF proprietary report, 0000-0099-4244-FBIR-P, Fuel Bundle Information Report for Clinton Power Station Unit 1 Reload 12 Cycle 13, Class III, (GNF-A Proprietary Information), Revision 0, dated December 2009. The GNF proprietary information in 0000-0099-4244-FBIR-P is identified by a dotted underline inside double square brackets. ((This sentence is an exampjl;e ...!!)) A

"((" marking at the beginning of a table, figure, or paragraph closed with a "))" marking at the end of the table, figure or paragraph is used to indicate that the entire content between the double brackets is proprietary. In each case, the superscript notation J31 refers to Paragraph (3) of this affidavit, which provides the basis for the proprietary determination.

(3) In making this application for withholding of proprietary information of which it is the owner or licensee, GNF-A relies upon the exemption from disclosure set forth in the Freedom of Information Act ("FOIA"), 5 USC Sec. 552(b)(4), and the Trade Secrets Act, 18 USC Sec. 1905, and NRC regulations 10 CFR 9.17(a)(4), and 2.390(a)(4) for "trade secrets" (Exemption 4). The material for which exemption from disclosure is here sought also qualify under the narrower definition of "trade secret", within the meanings assigned to those terms for purposes of FOIA Exemption 4 in, respectively, Critical Mass Energy Project v. Nuclear Regulatory Commission, 975F2d871 (DC Cir. 1992), and Public Citizen Health Research Group v. FDA, 704F2dl280 (DC Cir. 1983).

(4) Some examples of categories of information which fit into the definition of proprietary information are:

a. Information that discloses a process, method, or apparatus, including supporting data and analyses, where prevention of its use by GNF-A's competitors without license from GNF-A constitutes a competitive economic advantage over other companies;
b. Information which, if used by a competitor, would reduce his expenditure of resources or improve his competitive position in the design, manufacture, shipment, installation, assurance of quality, or licensing of a similar product;
c. Information which reveals aspects of past, present, or future GNF-A customer-funded development plans and programs, resulting in potential products to GNF-A;
d. Information which discloses patentable subject matter for which it may be desirable to obtain patent protection.

0000-0099-4244-FBIR-P Affidavit Page I of 3 COLR Page 18 of 53

Exelon Nuclear - Nuclear Fuels CL1C13 Core Operating Limits Report Non-Proprietary Information submitted in DOC ID: COLR Clinton 1 Rev. 4 Accordance with 10 CFR 2.390 Appendix A The information sought to be withheld is considered to be proprietary for the reasons set forth in paragraphs (4)a. and (4)b. above.

(5) To address 10 CFR 2.390 (b) (4), the information sought to be withheld is being submitted to NRC in confidence. The information is of a sort customarily held in confidence by GNF-A, and is in fact so held. The information sought to be withheld has, to the best of my knowledge and belief, consistently been held in confidence by GNF-A, no public disclosure has been made, and it is not available in public sources. All disclosures to third parties including any required transmittals to NRC, have been made, or must be made, pursuant to regulatory provisions or proprietary agreements which provide for maintenance of the information in confidence. Its initial designation as proprietary information, and the subsequent steps taken to prevent its unauthorized disclosure, are as set forth in paragraphs (6) and (7) following.

(6) Initial approval of proprietary treatment of a document is made by the manager of the originating component, the person most likely to be acquainted with the value and sensitivity of the information in relation to industry knowledge, or subject to the terms under which it was licensed to GNF-A. Access to such documents within GNF-A is limited on a "need to know" basis.

(7) The procedure for approval of external release of such a document typically requires review by the staff manager, project manager, principal scientist or other equivalent authority, by the manager of the cognizant marketing function (or his delegate), and by the Legal Operation, for technical content, competitive effect, and determination of the accuracy of the proprietary designation. Disclosures outside GNF-A are limited to regulatory bodies, customers, and potential customers, and their agents, suppliers, and licensees, and others with a legitimate need for the information, and then only in accordance with appropriate regulatory provisions or proprietary agreements.

(8) The information identified in paragraph (2) is classified as proprietary because it contains details of GNF-A's fuel design and licensing methodology.

The development of the methods used in these analyses, along with the testing, development and approval of the supporting methodology was achieved at a significant cost to GNF-A or its licensor.

0000-0099-4244-FBIR-P Affidavit Page 2 of 3 COLR Page 19 of 53

Exelon Nuclear - Nuclear Fuels CL1C13 Core Operating Limits Report Non-Proprietary Information submitted in DOC ID: COLR Clinton 1 Rev. 4 Accordance with 10 CFR 2.390 Appendix A (9) Public disclosure of the information sought to be withheld is likely to cause substantial harm to GNF-A's competitive position and foreclose or reduce the availability of profit-making opportunities. The information is part of GNF-A's comprehensive BWR safety and technology base, and its commercial value extends beyond the original development cost.

The value of the technology base goes beyond the extensive physical database and analytical methodology and includes development of the expertise to determine and apply the appropriate evaluation process. In addition, the technology base includes the value derived from providing analyses done with NRC-approved methods.

The research, development, engineering, analytical, and NRC review costs comprise a substantial investment of time and money by GNF-A.

The precise value of the expertise to devise an evaluation process and apply the correct analytical methodology is difficult to quantify, but it clearly is substantial.

GNF-A's competitive advantage will be lost if its competitors are able to use the results of the GNF-A experience to normalize or verify their own process or if they are able to claim an equivalent understanding by demonstrating that they can arrive at the same or similar conclusions.

The value of this information to GNF-A would be lost if the information were disclosed to the public. Making such information available to competitors without their having been required to undertake a similar expenditure of resources would unfairly provide competitors with a windfall, and deprive GNF-A of the opportunity to exercise its competitive advantage to seek an adequate return on its large investment in developing and obtaining these very valuable analytical tools.

I declare under penalty of perjury that the foregoing affidavit and the matters stated therein are true and correct to the best of my knowledge, information, and belief.

Executed on this 7 th day of December 2009.

Aitbonyi. R~eese Manager, Reload Design & Analysis Global Nuclear Fuel - Americas, LLC 0000-0099-4244-FBIR-P Affidavit Page 3 of 3 COLR Page 20 of 53

Exelon Nuclear - Nuclear Fuels CL1C13 Core Operating Limits Report Non-Proprietary Information submitted in DOC ID: COLR Clinton 1 Rev. 4 Accordance with 10 CFR 2.390 Appendix A Global Nuclear Fuel

'AJunitVcw~urEof 0E, olaa& i l 0000-0099-4244-FBIR-NP Revision 0 Class I December 2009 Non-ProprietaryInformation Fuel Bundle Information Report for Clinton Power Station Unit 1 Reload 12 Cycle 13 Copyright 2009 GlobalNuclear Fuels-Americas,LLC All Rights Reserved COLR Page 21 of 53

Exelon Nuclear - Nuclear Fuels CL1 C13 Core Operating Limits Report Non-Proprietary Information submitted in DOC ID: COLR Clinton 1 Rev. 4 Accordance with 10 CFR 2.390 Appendix A Clinton Non-Proprietary Information 0000-0099-4244-FBIR-NP Reload 12 Class I Revision 0 Class I Revision 0 Important Notice Regarding Contents of This Report Please Read Carefully This report was prepared. by Global Nuclear Fuel - Americas, LLC (GNF-A) solely for use by Exelon

("Recipient") in support of the operating license for Clinton (the "Nuclear Plant"). The information contained in this report (the "Information") is believed by GNF-A to be an accurate and true representation of the facts known by, obtained by or provided to GNF-A at the time this report was prepared.

The only undertakings of GNF-A respecting the Information are contained in the contract between Recipient and GNF-A for nuclear fuel and related services for the Nuclear Plant (the "Fuel Contract") and nothing contained in this document shall be construed as amending or modifying the Fuel Contract. The use of the Information for any purpose other than that for which it was intended under the Fuel Contract, is not authorized by GNF-A. In the event of any such unauthorized use, GNF-A neither (a) makes any representation or warranty (either expressed or implied) as to the completeness, accuracy or usefulness of the Information or that such unauthorized use may not infringe privately owned rights, nor (b) assumes any responsibility for liability or damage of any kind which may result from such use of such information.

Information Notice This is a non-proprietary version of the document 0000-0099-4244-FBIR-P, which has the proprietary information removed. Portions of the document that have been removed are indicated by an open and closed bracket as shown here (( )).

Page 2 COLR Page 22 of 53

Exelon Nuclear - Nuclear Fuels CL1C13 Core Operating Limits Report Non-Proprietary Information submitted in DOC ID: COLR Clinton 1 Rev. 4 Accordance with 10 CFR 2.390 Appendix A Clinton Non-Proprietary Information 0000-0099-4244-FBIR-NP Reload 12 Class I Revision 0

1. Introduction and Summary This report, which supplements the Supplemental Reload Licensing Report, contains thermal-mechanical linear heat generation rate (LHGR) limits for the GNF-A fuel designs to be loaded into Clinton Power Station Unit 1 for Cycle 13. These LHGR limits are obtained from thermal-mechanical considerations.

only. Approved GNF-A calculation models documented in Reference 1 were used in performing this analysis.

LHGR limits as a function of exposure for each bundle of the core design are given in Appendix A. The LHGR values provided in Appendix A provide upper and lower exposure dependent LHGR boundaries which envelope the actual gadolinia dependent LHGR limits. The LHGRs reported have been rounded to two places past the decimal.

Appendix B contains a description of the fuel bundles. Table B-1 contains a summary of bundle-specific information, and the figures provide the enrichment distribution and gadolinium distribution for the fuel bundles included in this appendix. These bundles have been approved for use under the fuel licensing acceptance criteria of Reference 1.

Page 3 COLR Page 23 of 53

Exelon Nuclear - Nuclear Fuels CL1C13 Core Operating Limits Report Non-Proprietary Information submitted in DOC ID: COLR Clinton 1 Rev. 4 Accordance with 10 CFR 2.390 Appendix A Clinton Non-Proprietary Information 0000-0099-4244-FBIR-NP Reload 12 Class I Revision 0

2. References
1. GeneralElectric StandardApplicationfor Reactor Fuel, NEDE-2401 I-P-A-16, October 2007; and the U.S. Supplement, NEDE-2401 1-P-A-16-US, October 2007.

Page 4 COLR Page 24 of 53

Exelon Nuclear - Nuclear Fuels CL1C13 Core Operating Limits Report Non-Proprietary Information submitted in DOC ID: COLR Clinton 1 Rev. 4 Accordance with 10 CFR 2.390 Appendix A Clinton Non-Proprietary Information 0000-0099-4244-FBIR-NP Reload 12 Class I Revision 0 evision 0 Appendix A U0 2/Gd Thermal-Mechanical LHGR Limits Bundle Type: GE 14-P 1OSNAB417-15GZ- 120T- 150-T6-3028 (GE14C)

Bundle Number: 3028 Peak Pellet Exposure U0 2 LHGR Limit GWd/MT (GWd/ST) kW/ft 0.00 (0.00) 13.40 16.00(14.51) 13.40 63.50 (57.61) 8.00 70.00 (63.50) 5.00 Peak Pellet Exposure Most Limiting Gadolinia LHGR Limit' GWd/MT (GWd/ST) kW/ft 0.00(0.00) 11.76 13.31 (12.08) 11.76 59.76 (54.21) 7.02 66.12 (59.98) 4.39 Bounding gadolinia LHGR limit for all gadolinium concentrations occurring in this bundle design ( 8.0% Gd).

Page 5 COLR Page 25 of 53

Exelon Nuclear - Nuclear Fuels CLIC13 Core Operating Limits Report Non-Proprietary Information submitted in DOC ID: COLR Clinton 1 Rev. 4 Accordance with 10 CFR 2.390 Appendix A Clinton Non-Proprietary Information 0000-0099-4244-FBIR-NP Reload 12 Class I Revision 0 UO2/Gd Thermal-Mechanical LHGR Limits Bundle Type: GE 14-P 1OSNAB418-14GZ- 120T- 150-T6-3027 (GE 14C)

Bundle Number: 3027 Peak Pellet Exposure U0 2 LHGR Limit GWd/MT (GWd/ST) kW/ft 0.00 (0.00) 13.40 16.00 (14.51) 13.40 63.50 (57.61) 8.00 70.00 (63.50) 5.00 Peak Pellet Exposure Most Limiting Gadolinia LHGR Limit 2 GWd/MT (GWd/ST) kW/ft 0.00 (0.00) 11.76 13.31 (12.08) 11.76 59.76 (54.21) 7.02 66.12 (59.98) 4.39 2 Bounding gadolinia LHGR limit for all gadolinium concentrations occurring in this bundle design ( 8.0% Gd).

Page 6 COLR Page 26 of 53

Exelon Nuclear - Nuclear Fuels CL1C13 Core Operating Limits Report Non-Proprietary Information submitted in DOC ID: COLR Clinton 1 Rev. 4 Accordance with 10 CFR 2.390 Appendix A Clinton Non-Proprietary Information 0000-0099-4244-FBIR-NP Reload 12 Class I Revision 0 U02/Gd Thermal-Mechanical LHGR Limits Bundle Type: GE 14-P 1OSNAB418-15GZ- 120T- 150-T6-3029 (GE 14C)

Bundle Number: 3029 Peak Pellet Exposure U0 2 LHGR Limit GWd/MT (GWd/ST) kW/ft 0.00 (0.00) 13.40 16.00 (14.51) 13.40 63.50 (57.61) 8.00 70.00 (63.50) 5.00 Peak Pellet Exposure Most Limiting Gadolinia LHGR Limit 3 GWd/MT (GWd/ST) kW/ft 0.00 (0.00) 11.76 13.31 (12.08) 11.76 59.76 (54.21) 7.02 66.12 (59.98) 4.39 3 Bounding gadolinia LHGR limit for all gadolinium concentrations occurring in this bundle design ( 8.0% Gd).

Page 7 COLR Page 27 of 53

Exelon Nuclear - Nuclear Fuels CL1C13 Core Operating Limits Report Non-Proprietary Information submitted in DOC ID: COLR Clinton 1 Rev. 4 Accordance with 10 CFR 2.390 Appendix A Clinton Non-Proprietary Information 0000-0099-4244-FBIR-NP Reload 12 Class I Revision 0 U0 2/Gd Thermal-Mechanical LHGR Limits Bundle Type: GE 14-P 10SNAB422-13GZ- 120T- 150-T6-3031 (GE 14C)

Bundle Number: 3031 Peak Pellet Exposure U0 2 LHGR Limit GWd/MT (GWd/ST) kW/ft 0.00 (0.00) 13.40 16.00 (14.51) 13.40 63.50 (57.61) 8.00 70.00 (63.50) 5.00 Peak Pellet Exposure Most Limiting Gadolinia LHGR Limit 4 GWd/MT (GWd/ST) kW/ft 0.00 (0.00) 11.76 13.31 (12.08) 11.76 59.76 (54.21) 7.02 66.12 (59.98) 4.39 4 Bounding gadolinia LHGR limit for all gadolinium concentrations occurring in this bundle design ( 8.0% Gd).

Page 8 COLR Page 28 of 53

Exelon Nuclear - Nuclear Fuels CL1C13 Core Operating Limits Report Non-Proprietary Information submitted in DOC ID: COLR Clinton 1 Rev. 4 Accordance with 10 CFR 2.390 Appendix A Clinton Non-Proprietary Information 0000-0099-4244-FBIR-NP Reload 12 Class I Revision 0 UO2/Gd Thermal-Mechanical LHGR Limits Bundle Type: GE 14-P 1OSNAB422-15GZ- 120T- 150-T6-3025 (GE 14C)

Bundle Number: 3025 Peak Pellet Exposure U0 2 LHGR Limit GWd/MT (GWd/ST) kW/ft 0.00 (0.00) 13.40 16.00 (14.51) 13.40 63.50 (57.61) 8.00 70.00 (63.50) 5.00 Peak Pellet Exposure Most Limiting Gadolinia LHGR Limit 5 GWd/MT (GWd/ST) kW/ft 0.00 (0.00) 11.76 13.31 (12.08) 11.76 59.76 (54.21) 7.02 66.12 (59.98) 4.39 5 Bounding gadolinia LHGR limit for all gadolinium concentrations occurring in this bundle design ( 8.0% Gd).

Page 9 COLR Page 29 of 53

Exelon Nuclear - Nuclear Fuels CL1C13 Core Operating Limits Report Non-Proprietary Information submitted in DOC ID: COLR Clinton 1 Rev. 4 Accordance with 10 CFR 2.390 Appendix A Clinton Non-Proprietary Information 0000-0099-4244-FBIR-NP Reload 12 Class I Revision 0 U0 2/Gd Thermal-Mechanical LHGR Limits Bundle Type: GE 14-P 1OSNAB419-14GZ- 120T- 150-T6-3030 (GE 14C)

Bundle Number: 3030 Peak Pellet Exposure U0 2 LHGR Limit GWd/MT (GWd/ST) kW/ft 0.00 (0.00) 13.40 16.00 (14.51) 13.40 63.50 (57.61) 8.00 70.00 (63.50) 5.00 Peak Pellet Exposure Most Limiting Gadolinia LHGR Limit 6 GWd/MT (GWd/ST) kW/ft 0.00 (0.00) 11.76 13.31 (12.08) 11.76 59.76 (54.21) 7.02 66.12((59.98) 4.39 6 Bounding gadolinia LHGR limit for all gadolinium concentrations occurring in this bundle design ( 8.0% Gd).

Page 10 COLR Page 30 of 53

Exelon Nuclear - Nuclear Fuels CL1C13 Core Operating Limits Report Non-Proprietary Information submitted in DOC ID: COLR Clinton 1 Rev. 4 Accordance with 10 CFR 2.390 Appendix A Clinton Non-Proprietary Information 0000-0099-4244-FBIR-NP Reload 12 Class I Revision 0 UO 2/Gd Thermal-Mechanical LHGR Limits Bundle Type: GE14-PIOSNAB413-16GZ-120T-150-T6-3026 (GE14C)

Bundle Number: 3026 Peak Pellet Exposure U0 2 LHGR Limit GWd/MT (GWd/ST) kW/ft 0.00 (0.00) 13.40 16.00 (14.51) 13.40 63.50 (57.61) 8.00 70.00 (63.50) 5.00 Peak Pellet Exposure Most Limiting Gadolinia LHGR Limit 7 GWd/MT (GWd/ST) kW/ft 0.00 (0.00) 11.76 13.31 (12.08) 11.76 59.76 (54.21) 7.02 66.12 (59.98) 4.39 7Bounding gadolinia LHGR limit for all gadolinium concentrations occurring in this bundle design ( 8.0% Gd).

Page 11 COLR Page 31 of 53

Exelon Nuclear - Nuclear Fuels CL1C13 Core Operating Limits Report Non-Proprietary Information submitted in DOC ID: COLR Clinton 1 Rev. 4 Accordance with 10 CFR 2.390 Appendix A Clinton Non-Proprietary Information 0000-0099-4244-FBIR-NP Reload 12 Class I Revision 0 UO2/Gd Thermal-Mechanical LHGR Limits Bundle Type: GE14-P1OSNAB418-15GZ-120T-150-T6-3240 (GE14C)

Bundle Number: 3240 Peak Pellet Exposure U0 2 LHGR Limit GWd/MT (GWd/ST) kW/ft 0.00 (0.00) 13.40 16.00 (14.51) 13.40 63.50 (57.61) 8.00 70.00 (63.50) 5.00 Peak Pellet Exposure Most Limiting Gadolinia LHGR Limit 8 GWd/MT (GWd/ST) kW/ft 0.00 (0.00) 11.76 13.31 (12.08) 11.76 59.76 (54.21) 7.02 66.12 (59.98) 4.39 8 Bounding gadolinia LHGR limit for all gadolinium concentrations occurring in this bundle design ( 8.0% Gd).

Page 12 COLR Page 32 of 53

Exelon Nuclear - Nuclear Fuels CL1C13 Core Operating Limits Report Non-Proprietary Information submitted in DOC ID: COLR Clinton 1 Rev. 4 Accordance with 10 CFR 2.390 Appendix A Clinton Non-Proprietary Information 0000-0099-4244-FBIR-NP Clas~s I Reload 12 Revision 0 Class 1 UO2/Gd Thermal-Mechanical LHGR Limits Bundle Type: GE 141-P 1OSCOB405-13GZ- 120T- 150-T6-3243 (GE 141)

Bundle Number: 3243 Peak Pellet Exposure U0 2 LHGR Limit GWd/MT (GWd/ST) kW/ft Peak Pellet Exposure Most Limiting Gadolinia LHGR Limit 9 GWd/MT (GWd/ST) kW/ft 9 Bounding gadolinia LHGR limit for all gadolinium concentrations occurring in this bundle design ((

Page 13 COLR Page 33 of 53

Exelon Nuclear - Nuclear Fuels CL1 C13 Core Operating Limits Report Non-Proprietary Information submitted in DOC ID: COLR Clinton 1 Rev. 4 Accordance with 10 CFR 2.390 Appendix A Clinton Non-Proprietary Information 0000-0099-4244-FBIR-NP Reload 12 Class I Revision 0 UO2/Gd Thermal-Mechanical LHGR Limits Bundle Type: GE 14-P 1OSNAB418-15GZ- 120T- 150-T6-3242 (GE 14C)

Bundle Number: 3242 Peak Pellet Exposure U0 2 LHGR Limit GWd/MT (GWd/ST) kW/ft 0.00 (0.00) 13.40 16.00 (14.51) 13.40 63.50 (57.61) 8.00 70.00 (63.50) 5.00 Peak Pellet Exposure Most Limiting Gadolinia LHGR Limit '0 GWd/MT (GWd/ST) kW/ft 0.00 (0.00) 11.76 13.31 (12.08) 11.76 59.76 (54.21) 7.02 66.12 (59.98) 4.39 10Bounding gadolinia LHGR limit for all gadolinium concentrations occurring in this bundle design ( 8.0% Gd).

Page 14 COLR Page 34 of 53

Exelon Nuclear - Nuclear Fuels CL1C13 Core Operating Limits Report Non-Proprietary Information submitted in DOC ID: COLR Clinton 1 Rev. 4 Accordance with 10 CFR 2.390 Appendix A Clinton Non-Proprietary Information 0000-0099-4244-FBIR-NP Reload 12 Class I Revision 0 UO 2/Gd Thermal-Mechanical LHGR Limits Bundle Type: GE 14-P 1OSNAB422-13GZ- 120T- 150-T6-3239 (GE 14C)

Bundle Number: 3239 Peak Pellet Exposure U0 2 LHGR Limit GWd/MT (GWd/ST) kW/ft 0.00 (0.00) 13.40 16.00 (14.51) 13.40 63.50 (57.61) 8.00 70.00 (63.50) 5.00 Peak Pellet Exposure Most Limiting Gadolinia LHGR Limit" GWd/MT (GWd/ST) kW/ft 0.00 (0.00) 11.76 13.31 (12.08) 11.76 59.76 (54.21) 7.02 66.12 (59.98) 4.39 Bounding gadolinia LHGR limit for all gadolinium concentrations occurring in this bundle design ( 8.0% Gd).

Page 15 COLR Page 35 of 53

Exelon Nuclear - Nuclear Fuels CL1 C13 Core Operating Limits Report Non-Proprietary Information submitted in DOC ID: COLR Clinton 1 Rev. 4 Accordance with 10 CFR 2.390 Appendix A Clinton Non-Proprietary Information 0000-0099-4244-FBIR-NP Reload 12 Class I Revision 0 U0 2/Gd Thermal-Mechanical LHGR Limits Bundle Type: GE14-P10SNAB418-15GZ-120T-150-T6-3241 (GE14C)

Bundle Number: 3241 Peak Pellet Exposure U0 2 LHGR Limit GWd/MT (GWd/ST) kW/ft 0.00 (0.00) 13.40 16.00 (14.51) 13.40 63.50 (57.61) 8.00 70.00 (63.50) 5.00 Peak Pellet Exposure Most Limiting Gadolinia LHGR Limit 12 GWd/MT (GWd/ST) kW/ft 0.00 (0.00) 11.76 13.31 (12.08) 11.76 59.76 (54.21) 7.02 66.12 (59.98) 4.39 12 Bounding gadolinia LHGR limit for all gadolinium concentrations occurring in this bundle design ( 8.0% Gd).

Page 16 COLR Page 36 of 53

Exelon Nuclear - Nuclear Fuels CL1C13 Core Operating Limits Report Non-Proprietary Information submitted in DOC ID: COLR Clinton 1 Rev. 4 Accordance with 10 CFR 2.390 Appendix A Clinton Non-Proprietary Information 0000-0099-4244-FBIR-NP Reload 12 Class I Revision 0 Revision 0 UO2/Gd Thermal-Mechanical LHGR Limits Bundle Type: GE 14-P 10SNAB420-15GZ- 120T- 150-T6-2870 (GE 14C)

Bundle Number: 2870 Peak Pellet Exposure U0 2 LHGR Limit GWd/MT (GWd/ST) kW/ft 0.00 (0.00) 13.40 16.00 (14.51) 13.40 63.50 (57.61) 8.00 70.00 (63.50) 5.00 Peak Pellet Exposure Most Limiting Gadolinia LHGR Limit 13 GWd/MT (GWd/ST) kW/ft 0.00 (0.00) 11.76 13.31 (12.08) 11.76 59.76 (54.21) 7.02 66.12 (59.98) 4.39 13Bounding gadolinia LHGR limit for all gadolinium concentrations occurring in this bundle design ( 8.0% Gd).

Page 17 COLR Page 37 of 53

Exelon Nuclear - Nuclear Fuels CL1C13 Core Operating Limits Report Non-Proprietary Information submitted in DOC ID: COLR Clinton 1 Rev. 4 Accordance with 10 CFR 2.390 Appendix A Clinton Non-Proprietary Information 0000-0099-4244-FBIR-NP Reload 12 Class I Revision 0 UO2/Gd Thermal-Mechanical LHGR Limits Bundle Type: GE14-P1OSNAB419-14GZ-120T-150-T6-2871 (GE14C)

Bundle Number: 2871 Peak Pellet Exposure U0 2 LHGR Limit GWd/MT (GWd/ST) kW/ft 0.00 (0.00) 13.40 16.00 (14.51) 13.40 63.50 (57.61) 8.00 70.00 (63.50) 5.00 Peak Pellet Exposure Most Limiting Gadolinia LHGR Limit 14 GWd/MT (GWd/ST) kW/ft 0.00 (0.00) 11.76 13.31 (12.08) 11.76 59.76 (54.21) 7.02 66.12 (59.98) 4.39 14 Bounding gadolinia LHGR limit for all gadolinium concentrations occurring in this bundle design ( 8.0% Gd).

Page 18 COLR Page 38 of 53

Exelon Nuclear - Nuclear Fuels CL1C13 Core Operating Limits Report Non-Proprietary Information submitted in DOC ID: COLR Clinton I Rev. 4 Accordance with 10 CFR 2.390 Appendix A Clinton Non-Proprietary Information 0000-0099-4244-FBIR-NP Reload 12 Class I Revision 0 evision 0 Appendix B Fuel Bundle Information Table B-1 Bundle Specific Information Weight Weight Max Exposure Fuel Bundle Enrichment of U0 2 of U k*, at at Max kc*

Bundle Number (wt% U-235) (kg) (kg) 20oC 15 GWd/MT (GWd/ST)

GEI4-P1OSNAB417-15GZ-120T-150-T6-3028 (GE14C)

GE14-P1OSNAB418-14GZ-120T-150-T6-3027 (GE14C)

GE14-P1OSNAB418-15GZ-120T-150-T6-3029 (GE14C)

GE 14-P 1OSNAB422-13GZ-120T-150-T6-3031 (GE14C)

GE 14-P 10SNAB422-15GZ-120T-150-T6-3025 (GE14C)

GEI4-P 1OSNAB419-14GZ-120T-150-T6-3030 (GE14C)

GE 14-PIOSNAB413-16GZ- 3026 120T-150-T6-3026 (GE14C)

GE14-PIOSNAB418-15GZ-120T-150-T6-3240 (GE14C)

GE141-P10SCOB405-13GZ- 3243 120T-150-T6-3243 (GE14I)

GE14-P10SNAB418-15GZ-120T-150-T6-3242 (GE14C)

GE 14-P IOSNAB422-133GZ- 3239 120T-150-T6-3239 (GE14C)

GE14-P1OSNAB418-15GZ-120T-150-T6-3241 (GE14C)

GE14-PIOSNAB420-15GZ-120T-150-T6-2870 (GE14C)

GE 14-P 1OSNAB419-14GZ-120T-150-T6-2871 (GE14C) 15 Maximum lattice k. for the most reactive uncontrolled state plus a (( )) adder for uncertainties.

Page 19 COLR Page 39 of 53

Exelon Nuclear - Nuclear Fuels CL1C13 Core Operating Limits Report Non-Proprietary Information submitted in DOC ID: COLR Clinton 1 Rev. 4 Accordance with 10 CFR 2.390 Appendix A Clinton Non-Proprietary Information 0000-0099-4244-FBIR-NP Reload 12 Class I Revision 0 1]

Figure B-1 Enrichment and Gadolinium Distribution for EDB No. 3028 Fuel Bundle GE14-P1OSNAB417-15GZ-120T-150-T6-3028 (GE14C)

Page 20 COLR Page 40 of 53

Exelon Nuclear - Nuclear Fuels CL1C13 Core Operating Limits Report Non-Proprietary Information submitted in DOC ID: COLR Clinton 1 Rev. 4 Accordance with 10 CFR 2.390 Appendix A Clinton Non-Proprietary Information 0000-0099-4244-FBIR-NP Reload 12 Class I Revision 0 Figure B-2 Enrichment and Gadolinium Distribution for EDB No. 3027 Fuel Bundle GE14-P1OSNAB418-14GZ-120T-150-T6-3027 (GE14C)

Page 21 COLR Page 41 of 53

Exelon Nuclear - Nuclear Fuels CL1 C13 Core Operating Limits Report Non-Proprietary Information submitted in DOC ID: COLR Clinton 1 Rev. 4 Accordance with 10 CFR 2.390 Appendix A Clinton Non-Proprietary Information 0000-0099-4244-FBIR-NP Reload 12 Class I Revision 0

((

1]

Figure B-3 Enrichment and Gadolinium Distribution for EDB No. 3029 Fuel Bundle GE14-P1OSNAB418-15GZ-120T-150-T6-3029 (GE14C)

Page 22 COLR Page 42 of 53

Exelon Nuclear - Nuclear Fuels CL1 C13 Core Operating Limits Report Non-Proprietary Information submitted in DOC ID: COLR Clinton 1 Rev. 4 Accordance with 10 CFR 2.390 Appendix A Clinton Non-Proprietary Information 0000-0099-4244-FBIR-NP Reload 12 Class I Revision '0 Figure B-4 Enrichment and Gadolinium Distribution for EDB No. 3031 Fuel Bundle GE14-P1OSNAB422-13GZ-120T-150-T6-3031 (GE14C)

Page 23 COLR Page 43 of 53

Exelon Nuclear - Nuclear Fuels CL1C13 Core Operating Limits Report Non-Proprietary Information submitted in DOC ID: COLR Clinton 1 Rev. 4 Accordance with 10 CFR 2.390 Appendix A Clinton Non-Proprietary Information 0000-0099-4244-FBIR-NP Reload 12 Class I Revision 0 evision 0 Figure B-5 Enrichment and Gadolinium Distribution for EDB No. 3025 Fuel Bundle GE14-P1OSNAB422-15GZ-120T-150-T6-3025 (GE14C)

Page 24 COLR Page 44 of 53

Exelon Nuclear - Nuclear Fuels CL1C13 Core Operating Limits Report Non-Proprietary Information submitted in DOC ID: COLR Clinton 1 Rev. 4 Accordance with 10 CFR 2.390 Appendix A Clinton Non-Proprietary Information 0000-0099-4244-FBIR-NP Reload 12 Class I Revision 0 1]

Figure B-6 Enrichment and Gadolinium Distribution for EDB No. 3030 Fuel Bundle GE14-P1OSNAB419-14GZ-120T-150-T6-3030 (GEI4C)

Page 25 COLR Page 45 of 53

Exelon Nuclear - Nuclear Fuels CL1C13 Core Operating Limits Report Non-Proprietary Information submitted in DOC ID: COLR Clinton 1 Rev. 4 Accordance with 10 CFR 2.390 Appendix A Clinton Non-Proprietary Information 0000-0099-4244-FBIR-NP Reload 12 Class I Revision 0 1]

Figure B-7 Enrichment and Gadolinium Distribution for EDB No. 3026 Fuel Bundle GE14-P1OSNAB413-16GZ-120T-150-T6-3026 (GE14C)

Page 26 COLR Page 46 of 53

Exelon Nuclear - Nuclear Fuels CL1C13 Core Operating Limits Report Non-Proprietary Information submitted in DOC ID: COLR Clinton 1 Rev. 4 Accordance with 10 CFR 2.390 Appendix A Clinton Non-Proprietary Information 0000-0099-4244-FBIR-NP Reload 12 Class I Revision 0 Figure B-8 Enrichment and Gadolinium Distribution for EDB No. 3240 Fuel Bundle GE14-PIOSNAB418-15GZ-120T-150-T6-3240 (GE14C)

Page 27 COLR Page 47 of 53

Exelon Nuclear - Nuclear Fuels CL1C13 Core Operating Limits Report Non-Proprietary Information submitted in DOC ID: COLR Clinton 1 Rev. 4 Accordance with 10 CFR 2.390 Appendix A Clinton Non-Proprietary Information 0000-0099-4244-FBIR-NP Reload 12 Class I Revision 0 11 Figure B-9 Enrichment and Gadolinium Distribution for EDB No. 3243 Fuel Bundle GEI4I-P1OSCOB405-13GZ-120T-150-T6-3243 (GE14I)

Page 28 COLR Page 48 of 53

Exelon Nuclear - Nuclear Fuels CL1C13 Core Operating Limits Report Non-Proprietary Information submitted in DOC ID: COLR Clinton 1 Rev. 4 Accordance with 10 CFR 2.390 Appendix A Clinton Non-Proprietary Information 0000-0099-4244-FBIR-NP Reload 12 Class I Revision 0 Figure B-10 Enrichment and Gadolinium Distribution for EDB No. 3242 Fuel Bundle GE14-P1OSNAB418-15GZ-120T-150-T6-3242 (GE14C)

Page 29 COLR Page 49 of 53

Exelon Nuclear - Nuclear Fuels CL1 C13 Core Operating Limits Report Non-Proprietary Information submitted in DOC ID: COLR Clinton 1 Rev. 4 Accordance with 10 CFR 2.390 Appendix A Clinton Non-Proprietary Information 0000-0099-4244-FBIR-NP Reload 12 Class I Revision 0 1

Figure B-11 Enrichment and Gadolinium Distribution for EDB No. 3239 Fuel Bundle GE14-PlOSNAB422-13GZ-120T-150-T6-3239 (GE14C)

Page 30 COLR Page 50 of 53

Exelon Nuclear - Nuclear Fuels CL1C13 Core Operating Limits Report Non-Proprietary Information submitted in DOC ID: COLR Clinton 1 Rev. 4 Accordance with 10 CFR 2.390 Appendix A Clinton Non-Proprietary Information 0000-0099-4244-FBIR-NP Reload 12 Class I Revision 0 Figure B-12 Enrichment and Gadolinium Distribution for EDB No. 3241 Fuel Bundle GE14-P1OSNAB418-15GZ-120T-150-T6-3241 (GE14C)

Page 31 COLR Page 51 of 53

Exelon Nuclear - Nuclear Fuels CL1C13 Core Operating Limits Report Non-Proprietary Information submitted in DOC ID: COLR Clinton 1 Rev. 4 Accordance with 10 CFR 2.390 Appendix A Clinton Non-Proprietary Information 0000-0099-4244-FBIR-NP Reload 12 Class I Revision 0 Figure B-13 Enrichment and Gadolinium Distribution for EDB No. 2870 Fuel Bundle GE14-P1OSNAB420-15GZ-120T-150-T6-2870 (GE14C)

Page 32 COLR Page 52 of 53

Exelon Nuclear - Nuclear Fuels CL1C13 Core Operating Limits Report Non-Proprietary Information submitted in DOC ID: COLR Clinton 1 Rev. 4 Accordance with 10 CFR 2.390 Appendix A Clinton Non-Proprietary Information 0000-0099-4244-FBIR-NP Reload 12 Class I Revision 0 Figure B-14 Enrichment and Gadolinium Distribution for EDB No. 2871 Fuel Bundle GE14-P1OSNAB419-14GZ-120T-150-T6-2871 (GE14C)

Page 33 COLR Page 53 of 53