Core Operating Limits Report for Clinton Power Station, Unit 1 Cycle 10 Revision 0

Issuance of Changes Summary Affected Affected Summary of Changes i

Section Pages I Revision Date All All Original Issue (Cycle 10) 0 1/04 Clinton Unit 1 Cycle 10 ii Revision 0

Table of Contents References.....

iv

1.

Average Planar Linear Heat Generation Rate (3.2.1 and 3.4.1).1-1 1.1 Technical Specification Reference.1-1 1.2 Description.1-1

2.

Minimum Critical Power Ratio (3.2.2 and 3.4.1)...

2-1 2.1 Technical Specification Reference.2-1 2.2 Description.2-1

3.

Linear Heat Generation Rate (3.2.3).3-1 3.1 Technical Specification Reference.3-1 3.2 Description.3-1

4.

Reactor Protection System (RPS) Instrumentation (3.3.1.1).4-1 4.1 Technical Specification Reference.4-1 4.2 Description.4-1

5.

Allowed Modes of Operation (B 3.2.2, B 3.2.3).5-1

6.

Methodology (5.6.5).6-1 Clinton Unit 1 Cycle 10 iii Revision 0

References

1.

Clinton Power Station Technical Specification 5.6.6, Core Operating Limits Report (COLR).

2.

Letter from D. M. Crutchfield to All Power Reactor Licensees and Applicants, Generic Letter 88-16; Concerning the Removal of Cycle-Specific Parameter Limits from Tech Specs, October 3,1988.

3.

Document 0000-0016-5277SRLR Revision 0, "Supplemental Reload Licensing Report for Clinton Power Station Unit 1 Reload 9 Cycle 10", December 2003.

4.

TODI NF0300064 Revision 0, "OPL-3 Parameters for Clinton Unit 1 Cycle 10 Transient Analysis", August 19, 2003.

5.

Document 0000-0016-5277FBIR Revision 0, 'Fuel Bundle Information Report for Clinton Power Station Unit 1 Reload 9 Cycle 10", December 2003

6.

Document GE-NE-0000-0000-7456-01 P. 'Option B Scram Times For Clinton Power Station", February 2002

7.

TODI NF0300050 Revision 0, "Clinton Cycle 10 FRED Form", June 10, 2003

8.

General Electric Standard Application for Reactor Fuel (GESTAR II) and US supplement, NEDE-24011 -P-A-14, June 2000.

9.

NEDC-31546P, -Maximum Extended Operating Domain and Feedwater Heater Out-of-Service Analysis for Clinton Power Station," August 1988.

10.

DB-001 2.03, Revision 0, GE Nuclear Energy Design Basis Document, 'Fuel-Rod Thermal-Mechanical Performance Limits for GE14C," May 2000.

11.

Letter to Nuclear Regulatory Commission from J. S. Perry (IP), "Clinton Power Station Proposed Amendment of Facility Operating License No. NFP-62," U-602085 [LS-92-004],

February 11, 1993.

12.

Letter to F. A. Spangenberg (IP) from D. V. Pickett (NRC), Issuance of Amendment [No.

75] (TAC No. M85816), May 25,1993.

13.

RDW:95-160, "Simulated Thermal Power Monitor," letter from R. D. Williams (GE) to J. A.

Miller (Clinton), November 16, 1995.

14.

NEDC-32694P-A, "Power Distribution Uncertainties for Safety Limit MCPR Evaluations,"

August 1999.

Clinton Unit 1 Cycle 10 iv Revision 0

1.

Average Planar Linear Heat Generation Rate 1.1 Technical Specification

Reference:

Sections 3.2.1 and 3.4.1.

1.2

==

Description:==

Table 1-1 is used to determine the maximum average planar linear heat generation rate (MAPLHGR) limit for each fuel type. Limits listed in Table 1-1 are for dual reactor recirculation loop operation (DLO).

For single reactor recirculation loop operation (SLO), the MAPLHGR limits given in Table 1-1 must be multiplied by a SLO MAPLHGR multiplier provided in Table 1-2. The SLO MAPLHGR multiplier for GE14 fuel is 0.76 (Reference 3).

Table 1-1 Maximum Average Planar Linear Heat Generation Rate (MAPLHGR) for all GE14C Fuel (Reference 3)

Avg. Planar MAPLHGR Exposure Limit (GWd/ST)

(kW/ft) 0.00 12.82 14.51 12.82 19.13 12.82 57.61 8.00 63.50 5.00 Note for Table 1-1:

Linear Interpolation should be used for points not listed In Table 1-1.

Table 1-2 MAPLHGR SLO Multiplier (Reference 3) l Fuel MAPLHGR Fuel SLO Type Multiplier__

I GE1 4C 0.76 l

Clinton Unit 1 Cycle 10 1-1 Revision 0

2.

Minimum Critical Power Ratio 2.1 Technical Specification

Reference:

Sections 3.2.2 and 3.4.1 2.2

==

Description:==

The various MCPR limits are described below.

2.2.1 Manual Flow Control MCPR Limits The Operating Limit MCPR (OLMCPR) is determined from either section 2.2.1.1 or 2.2.1.2, whichever is greater at any given power and flow condition.

2.2.1.1 Power-Dependent MCPR (MCPR4)

For operation less than or equal to 33.3% core thermal power, the OLMCPR as a function of core thermal power is shown in Table 2-3. For operation at greater than 33.3% core thermal power, the OLMCPR as a function of core thermal power is determined by multiplying the applicable rated condition OLMCPR limit shown in Table 2-1 or 2-2 by the applicable MCPR multiplier K(P) given in Table 2-3.

2.2.1.2 Flow-Dependent MCPR (MCPRd Tables 2-4 through 2-7 give the MCPRF as a function of flow based on the applicable plant condition. The limits for dual loop operation are listed in Tables 2-4 and 2-5. The limits for single loop operation are listed in Tables 2-6 and 2-7. The MCPRF determined from these tables is the flow dependent OLMCPR.

2.2.2 Automatic Flow Control MCPR Limits Automatic Flow Control MCPR Limits are not provided.

2.2.3 Option A and Option B Option A and Option B refer to use of scram speeds for establishing MCPR operating limits.

Option A scram speed is the BWR/6 Technical Specification scram speed. The Technical Specification scram speeds must be met to utilize the Option A MCPR limits. Reload analyses performed by GNF for cycle 10 Option A MCPR limits utilized a 20% core average insertion time of 0.516 seconds.

To utilize the MCPR limits for the Option B scram speed, the cycle average scram insertion time for 20% insertion must satisfy equation 2 in Reference 6 Section 4. If the cycle average scram insertion time does not meet the Option B criteria, the appropriate MCPR value may be Clinton Unit 1 Cycle 10 2-1 Revision 0

determined from a linear interpolation between the Option A and B limits as specified by equation 4 in Reference 6 Section 4.

2.2.4 Recirculation Flow Control Valve Settings Cycle 10 was analyzed with a maximum core flow runout of 109%;

therefore the recirculation flow control valve must be set to maintain core flow less than 109% (92.105 Mlb/hr) for all runout events (Reference 7).

This value is consistent with the analyses of Reference 3.

Clinton Unit 1 Cycle 10 2-2 Revision 0

Table 2-1 MCPR Option A Based Operating Limits (Reference 3)

Fuel Cycle Exposure EOOS Combination Type All exposures Base Case GE14C 1.30 Base Case SLO

[ GE14C 1.33 Table 2-2 MCPR Option B Based Operating Limits (Reference 3)

Fuel Cycle Exposure EOOS Combination Type All exposures All GE14C except for Base Case GE14-PI OSNAB395-16GZ-120T-150-T6-2521 1.27 Base Case GE14-PI OSNAB395-16GZ-120T-150-T6-2521 1.28 All GEl4C except for Base Case SLO GE14-P1OSNAB395-16GZ-120T-150-T6-2521 1.30 Base Case SLO GE14-Pl OSNAB395-16GZ-120T-150-T6-2521 1.31 Clinton Unit 1 Cycle 10 2-3 Revision 0

Table 2-3 MCPRp for all GE14 Fuel (Reference 3) 1r Core Thermal Power (% Rated)

EOOS Combination Flow 0 l 21.6

<33.3

>33.3

<70 l

>70 100 MCPRp Kp

< 50 2.20 2.20 1.97.

Base Case 1.351 1.212 1.15 1.00

> 50 2.46 2.46 2.17

< 50 2.23 2.23 2.00 Base Case SLO 1.351 1.212 1.15 1.00

> 50 2.49 2.49 2.20 Notes for Table 2-3:

Core flow units are in percent (%) of rated.

Values are Interpolated between relevant power levels.

For thermal limit monitoring at greater than 100% core thermal power, the 1001% core thermal power multiplier K(P) should be applied.

Allowable EOOS conditions are listed In Section 5.

Clinton Unit 1 Cycle 10 2-4 Revision 0

Table 2-4 MCPRF for Base Case for GE14C Fuel except for GE1 4-P1 OSNAB395-1 6GZ-1 20T-1 50-T6-2521 (Reference 3)

Core Flow MCPRF

(% rated)

Il_

0.00 1.8754 25.00 1.6954 93.78 1.20 109.00 1.20 Table 2-5 MCPRF for Base Case for GE1 4-Pl OSNAB395-1 6GZ-1 20T-1 50-T6-2521 (Reference 3)

[Core Flow MCR

(% rated) l F

0.00 1.8754 25.00 1.6954 82.67 1.28 109.00 1.28 Note for Table 2-4 and 2-5:

Linear Interpolation should be used for points not listed In the table.

Clinton Unit 1 Cycle 10 2-5 Revision 0

Table 2-6 MCPRF for Base Case SLO for GE14C Fuel except for G El 4-PI OSNAB395-16GZ-1 20T-1 50-T6-2521 (Reference 3)

Core Flow IMCPRF

(% rated) l______

0.00 1.9054 25.00 1.7254 93.78 1.23 109.00 1.23 Table 2-7 MCPRF for Base Case SLO for GE14-PI OSNAB395-16GZ-120T-150-T6-2521 (Reference 3)

Core Flow MCPRF

(% rated) l____

0.00 1.9054 25.00 1.7254 82.67 1.31 109.00 1.31 Note for Table 2-6 and Table 2-7:

Unear Interpolation should be used for points not listed In the tables.

Clinton Unit 1 Cycle 10 2-6 Revision 0

3.

Linear Heat Generation Rate (3.2.3) 3.1 Technical Specification

Reference:

Section 3.2.3.

3.2

==

Description:==

The linear heat generation rate (LHGR) limit is the product of the exposure dependent LHGR limit (from Table 3-1 for U02 fuel rods and Tables 3-2 through 3-4 for Gadolinia fuel rods) and the minimum of: the power dependent LHGR Factor, LHGRFACp, the flow dependent LHGR Factor, LHGRFACF, or the single loop operation (SLO) multiplication factor if applicable. The LHGRFACp is determined from Table 3-5. The LHGRFACF is determined from Table 3-6. The SLO multiplication factor can be found in Table 3-7. Tables 3-1 through 3-4 are the LHGR limit as a function of peak pellet exposure.

The Gadolinia fuel rod limits in Tables 3-2 through 3-4 are the most limiting Gadolinia fuel rods. The most limiting values are provided here as a convenience and do not imply that all the Gadolinia fuel rods must satisfy the listed values.

Table 3-1 LHGR Limits for GE14C U02 Fuel rods (Reference 5)

Peak Pellet LHGR Exposure Limit (GWd/ST)

(kW/ft) 0.00 13.40 Note for Table 3-1:

Unear Interpolation should be used for points not listed In Table 3-1.

t U3-1 Clinton Unit 1 Cycle 1 0 Revision 0

Table 3-2 LHGR Limits for GE14C Gadolinia Fuel rods for GE14-Pl OSNAB353-13GZ-120T-150-T6-3894 and GE14-PI OSNAB354-15GZ-120T-150-T6-3895 bundles (Reference 5)

Peak Pellet LHGR Exposure Limit (GWdIST)

( kW/ft)

Table 3-3 LHGR Limits for GE14C Gadolinia Fuel rods for GE1 4-P1 OSNAB395-16GZ-1 2OT-1 50-T6-2521 and GE14-Pl OSNAB422-18GZ-120T-150-T6-2653 bundles (Reference 5)

Peak Pellet LHGR Exposure Limit (GWd/ST)

(kW/ft)

Note for Table 3-2 and 3-3 Linear Interpolation should be used for points not listed In the tables.

Clinton Unit 1 Cycle 10 3-2 Revision 0

Table 3-4 LHGR Limits for GE14C Gadolinia Fuel rods for GE14-Pl OSNAB385-16GZ-120T-150-T6-2522, GE14-PI OSNAB422-18GZ-120T-150-T6-2648 and GE14-Pl OSNAB419-15GZ-120T-150-T6-2649 bundles (Reference 5)

Peak Pellet LHGR Exposure Limit (GWd/ST)

(kW/ft)

Note for Table 3-4 Linear Interpolation should be used for points not listed In Table 3-4.

Clinton Unit 1 Cycle 10 3-E Revision 0

Table 3-5 LHGRFACp for G14C Fuel (Reference 3)

Core Thermal Power (% Rated)

EOOS Combination Flow 0

l 21.6 l< 33.3 1 > 33.3 l 40 l<60 l >60 l 100 LHGRFACP Base Case

< 50 0.634 0.634 0.689 0.689

> 50 0.572 0.572 0.600 Base Case SLO

< 50 0.634 0.634 0.689 0.689

> 50 0.572 0.572 0.600 1.00 1.00 Notes for Table 3-5:

Values are interpolated between relevant power levels.

For thermal limit monitoring at greater than 1OO% core thermal power, the 100% core thermal power LHGRFACp multiplier should be applied.

Allowable EOOS conditions are listed In Section 5.

Clinton Unit 1 Cycle 10 3-4 Revision 0

Table 3-6 LHGRFACp for all cases for GE14C Fuel (Reference 3)

Core Flow LHGRFACp

(% rated) I 0.00 0.4430 30.00 0.6463 82.18 1.00 109.00 1.00 Note for Table 3-6 Unear Interpolation should be used for points not listed In Table 3-6.

Table 3-7 LHGR SLO Multiplier (Reference 3)

Fuel LHGR Fuel SLO Type Multiplier GE140 -F 0.76 Clinton Unit 1 Cycle 10 3-5 Revision 0

4.

Reactor Protection System (RPS) Instrumentation 4.1 Technical Specification

Reference:

3.3.1.1 4.2

==

Description:==

The Average Power Range Monitor (APRM) simulated thermal power time, constant, References 11 and 12, shall be between 5.4 seconds and 6.6 seconds (6.0+/-0.6 seconds) as described in Reference 13.

Clinton Unit 1 Cycle 10 4-1 Revision 0

5.

Allowed Modes of Operation The Allowed Modes of Operation with combinations of Equipment Out-of-Service (EOOS) are as described below:

T1 I

Operating Region EOOS Options'>

l 7

Standard l

MELLLA ICF l Coastdowns Base Case, Option A Yes Yes Yes Yes Base Case SLO6, Option A Yes No No Yes Base Case, Option B Yes Yes Yes Yes Base Case SLO6, Option B Yes I

No No Yes

' See References 8 and 14 for restrictions related to TIP and LPRM system operability.

2 The Base case was analyzed with two (2) Safety-Relief Valves Out-of-Service (OOS), one (1) ADS valve OOS, and up to a 500F feedwater temperature reduction (feedwater heater OOS or final feedwater temperature reduction) at any point in the cycle operation in Dual Loop mode (Reference 3).

3 A single Main Steam Isolation Valve (MSIV) may be taken OOS (shut) under any one OOS Option so long as core thermal power is maintained *75% of 3473 MWt (Reference 3).

4The maximum ICF flow utilized in licensing analysis is 107.0% (Reference 3).

5 Design coastdown operation is defined as any cycle exposure beyond the full power, all rods out condition with plant power slowly lowering to a lesser value while core flow is held constant.

6 Concurrent operation with SLO and feedwater temperature reduction has not been evaluated and thus not a valid operating mode. (Reference 3) 7 Pressure Regulator Out-Of-Service (PROOS) was evaluated for thermal limits only in dual loop mode with up to 1 00lF feedwater temperature reduction at any point in the cycle (Reference 3). PROOS has not been evaluated for Balance of Plant operation.

Clinton Unit 1 Cycle 10 5-1 Revision 0

6.

Methodology The analytical methods used to determine the core operating limits shall be those previously reviewed and approved by the NRC, specifically those described in the following documents:

1. NEDE-24011-P-A-14 Revision 14, "General Electric Standard Application for Reactor Fuel (GESTAR),"

June 2000.

Clinton Unit 1 Cycle 10 6-1 Revision 0