ES-301 Administrative Topics Outline Form ES-301-1 Facility: __Cooper Nuclear Station__________

Date of Examination: _9/21/2009___

Examination Level: RO X SRO Operating Test Number: __________

Administrative Topic (see Note)

Type Code*

Describe activity to be performed Conduct of Operations S, D, P Obtain and Interpret a GARDEL Periodic Case Conduct of Operations NOT TESTED Equipment Control S, D Determine isolation boundaries for REC pump wearing ring replacement.

Radiation Control R,D Radiation Protection Table top scenario Emergency Procedures/Plan R, N Determine RPV water level instrumentation availability during LOCA conditions NOTE: All items (5 total) are required for SROs. RO applicants require only 4 items unless they are retaking only the administrative topics, when all 5 are required.

  • Type Codes & Criteria:

(C)ontrol room, (S)imulator, or Class(R)oom (D)irect from bank ( 3 for ROs; 4 for SROs & RO retakes)

(N)ew or (M)odified from bank ( 1)

(P)revious 2 exams ( 1; randomly selected)

ES-301 Administrative Topics Outline Form ES-301-1 Facility: __Cooper Nuclear Station__________

Date of Examination: _9/21/2009___

Examination Level: RO SRO X Operating Test Number: __________

Administrative Topic (see Note)

Type Code*

Describe activity to be performed Conduct of Operations S, M Security Emergency Conduct of Operations R, D Determine if Shift Staffing requirements are adequate for mode change Equipment Control S, D Review Jet Pump Operability Test Radiation Control R, D Review and Approve a Liquid Radioactive Waste Discharge Permit Emergency Procedures/Plan D, R, P EAL Table Top NOTE: All items (5 total) are required for SROs. RO applicants require only 4 items unless they are retaking only the administrative topics, when all 5 are required.

  • Type Codes & Criteria:

(C)ontrol room, (S)imulator, or Class(R)oom (D)irect from bank ( 3 for ROs; 4 for SROs & RO retakes)

(N)ew or (M)odified from bank ( 1)

(P)revious 2 exams ( 1; randomly selected)

ES-301 Control Room/In-Plant Systems Outline Form ES-301-2 Facility: ___Cooper Nuclear Station____________

Date of Examination: _9/21/2009____

Exam Level: RO X SRO-I SRO-U Operating Test No.: ______________

Control Room Systems@ (8 for RO); (7 for SRO-I); (2 or 3 for SRO-U, including 1 ESF)

System / JPM Title Type Code*

Safety Function

a. Respond to a Trip of a Reactor Recirc Pump (Alternate Path)

A,D,S 1

b. Perform quick Restart of RFPT B (Hard Card) (Alternate Path)

A,M,P,S 2

c. Transfer Governor Valve Control from Manual to Auto with DEH in Mode IV D,S 3
d. High Pressure Coolant Injection / Manually Initiate EN,M,S, L 4
e. Align REC for Drywell Cooling after REC isolation on Low Pressure D, S 8
f. Transfer of 4160V Bus 1G from DG2 to Emergency Transformer D,L,P,S 6
g. Install EOP PTMs 57, 58, 59, 60 D, S 7
h. SGT System Support for HPCI operations (Alternate Path)

A,EN,M,S,L 9

In-Plant Systems@ (3 for RO); (3 for SRO-I); (3 or 2 for SRO-U)

i. Manually Vent the Scram Air Header E,D,P,R 1
j. Respond to No Break Power Panel Failure (Alternate Path)

A,D 6

k. Inject Fire Water into RHR (Level control)

D,E 2

All RO and SRO-I control room (and in-plant) systems must be different and serve different safety functions; all 5 SRO-U systems must serve different safety functions; in-plant systems and functions may overlap those tested in the control room.

  • Type Codes Criteria for RO / SRO-I / SRO-U (A)lternate path (C)ontrol room (D)irect from bank (E)mergency or abnormal in-plant (EN)gineered safety feature (L)ow-Power / Shutdown (N)ew or (M)odified from bank including 1(A)

(P)revious 2 exams (R)CA (S)imulator 4-6 / 4-6 / 2-3 9 / 8 / 4 1 / 1 / 1

- / - / 1 (control room system) 1 / 1 / 1 2 / 2 / 1 3 / 3 / 2 (randomly selected) 1 / 1 / 1

ES-301 Control Room/In-Plant Systems Outline Form ES-301-2 Facility: ___Cooper Nuclear Station____________

Date of Examination: _9/21/2009____

Exam Level: RO SRO-I SRO-U X Operating Test No.: ______________

Control Room Systems@ (8 for RO); (7 for SRO-I); (2 or 3 for SRO-U, including 1 ESF)

System / JPM Title Type Code*

Safety Function

a.
b. High Pressure Coolant Injection / Manually Initiate EN,M,S,L 4
c.
d. Perform quick Restart of RFPT B (Hard Card) (Alternate Path)

A,M,P,S 2

e.
f.
g.
h. SGT System Support for HPCI operations (Alternate Path)

A,EN,M,S,L 9

In-Plant Systems@ (3 for RO); (3 for SRO-I); (3 or 2 for SRO-U)

i. Manually Vent the Scram Air Header, per 5.8.3 E,D,P,R 1
j. Respond to No Break Power Panel Failure (Alternate Path)

A,D 6

k.

All RO and SRO-I control room (and in-plant) systems must be different and serve different safety functions; all 5 SRO-U systems must serve different safety functions; in-plant systems and functions may overlap those tested in the control room.

  • Type Codes Criteria for RO / SRO-I / SRO-U (A)lternate path (C)ontrol room (D)irect from bank (E)mergency or abnormal in-plant (EN)gineered safety feature (L)ow-Power / Shutdown (N)ew or (M)odified from bank including 1(A)

(P)revious 2 exams (R)CA (S)imulator 4-6 / 4-6 / 2-3 9 / 8 / 4 1 / 1 / 1

- / - / 1 (control room system) 1 / 1 / 1 2 / 2 / 1 3 / 3 / 2 (randomly selected) 1 / 1 / 1

ES-301 Control Room/In-Plant Systems Outline Form ES-301-2 Facility: ___Cooper Nuclear Station____________

Date of Examination: _9/21/2009____

Exam Level: RO SRO-I X SRO-U Operating Test No.: ______________

Control Room Systems@ (8 for RO); (7 for SRO-I); (2 or 3 for SRO-U, including 1 ESF)

System / JPM Title Type Code*

Safety Function

a. Respond to a Trip of a Reactor Recirc Pump (Alternate Path)

A,D,S 1

b. Perform quick Restart of RFPT B (Hard Card) (Alternate Path)

A,M,P,S 2

c. Transfer Governor Valve Control from Manual to Auto with DEH in Mode IV D,S 3
d. High Pressure Coolant Injection / Manually Initiate EN,M,S, L 4
e. Align REC for Drywell Cooling after REC isolation on Low Pressure D, S 8
f. Transfer of 4160V Bus 1G from DG2 to Emergency Transformer D,L,P,S 6
g.
h. SGT System Support for HPCI operations (Alternate Path)

A,EN,M,S,L 9

In-Plant Systems@ (3 for RO); (3 for SRO-I); (3 or 2 for SRO-U)

i. Manually Vent the Scram Air Header E,D,P,R 1
j. Respond to No Break Power Panel Failure (Alternate Path)

A,D 6

k. Inject Fire Water into RHR (Level control)

D,E 2

All RO and SRO-I control room (and in-plant) systems must be different and serve different safety functions; all 5 SRO-U systems must serve different safety functions; in-plant systems and functions may overlap those tested in the control room.

  • Type Codes Criteria for RO / SRO-I / SRO-U (A)lternate path (C)ontrol room (D)irect from bank (E)mergency or abnormal in-plant (EN)gineered safety feature (L)ow-Power / Shutdown (N)ew or (M)odified from bank including 1(A)

(P)revious 2 exams (R)CA (S)imulator 4-6 / 4-6 / 2-3 9 / 8 / 4 1 / 1 / 1

- / - / 1 (control room system) 1 / 1 / 1 2 / 2 / 1 3 / 3 / 2 (randomly selected) 1 / 1 / 1

ES-301 Transient and Event Checklist Form ES-301-5 Facility:

Date of Exam:

Operating Test No.:

Scenarios 1

2 3

4 CREW POSITION CREW POSITION CREW POSITION CREW POSITION M

I N

I M

U M(*)

A P

P L

I C

A N

T E

V E

N T

T Y

P E

S R

O A

T C

B O

P S

R O

A T

C B

O P

S R

O A

T C

B O

P S

R O

A T

C B

O P

T O

T A

L R

I U

RX 1

1 1 0 NOR 1

1 1 1 I/C 3

3 4

4 2 MAJ 1

2 2

2 1 RO X

SRO-I SRO-U TS 0

2 2 RX 1

1 1 0 NOR 1

1 1 1 I/C 3

4 4

4 2 MAJ 1

2 2

2 1 RO SRO-I X

SRO-U TS 2

0 2 2 RX 1

1 0 NOR 2

1 1 1 I/C 5

4 4 2 MAJ 1

2 2 1 RO SRO-I SRO-U X

TS 2

0 2 2 RX 1

1 1 0 NOR 1

1 1 1 I/C 3

4 4

4 2 MAJ 1

2 2

2 1 RO X

SRO-I SRO-U TS 0

2 2

Instructions:

1.

Check the applicant level and enter the operating test number and Form ES-D-1 event numbers for each event type; TS are not applicable for RO applicants. ROs must serve in both the at-the-controls (ATC) and balance-of-plant (BOP) positions; Instant SROs must serve in both the SRO and the ATC positions, including at least two instrument or component (I/C) malfunctions and one major transient, in the ATC position. If an Instant SRO additionally serves in the BOP position, one I/C malfunction can be credited toward the two I/C malfunctions required for the ATC position.

2.

Reactivity manipulations may be conducted under normal or controlled abnormal conditions (refer to Section D.5.d) but must be significant per Section C.2.a of Appendix D. (*) Reactivity and normal evolutions may be replaced with additional instrument or component malfunctions on a 1-for-1 basis.

3. Whenever practical, both instrument and component malfunctions should be included; only those that require verifiable actions that provide insight to the applicants competence count toward the minimum requirements specified for the applicants license level in the right-hand columns.

ES-301 Transient and Event Checklist Form ES-301-5 Facility:

Date of Exam:

Operating Test No.:

Scenarios 1

2 3

4 CREW POSITION CREW POSITION CREW POSITION CREW POSITION M

I N

I M

U M(*)

A P

P L

I C

A N

T E

V E

N T

T Y

P E

S R

O A

T C

B O

P S

R O

A T

C B

O P

S R

O A

T C

B O

P S

R O

A T

C B

O P

T O

T A

L R

I U

RX 1

1 1 0 NOR 1

1 1 1 I/C 5

3 4

4 2 MAJ 1

2 2

2 1 RO SRO-I X

SRO-U TS 2

0 2 2 RX 1

1 0 NOR 1

1 1 1 I/C 4

4 4 2 MAJ 2

2 2 1 RO SRO-I SRO-U X

TS 2

0 2 2 RX 2

1 1 0 NOR 1

1 1 1 I/C 4

3 4

4 2 MAJ 2

2 2

2 1 RO X

SRO-I SRO-U TS 0

2 2 RX 1

1 1 0 NOR 1

1 1

1 1 I/C 3

3 2

4 4 2 MAJ 1

2 2

2 2 1 RO X

SRO-I SRO-U TS 0

2 2 Instructions:

3.

Check the applicant level and enter the operating test number and Form ES-D-1 event numbers for each event type; TS are not applicable for RO applicants. ROs must serve in both the at-the-controls (ATC) and balance-of-plant (BOP) positions; Instant SROs must serve in both the SRO and the ATC positions, including at least two instrument or component (I/C) malfunctions and one major transient, in the ATC position. If an Instant SRO additionally serves in the BOP position, one I/C malfunction can be credited toward the two I/C malfunctions required for the ATC position.

4.

Reactivity manipulations may be conducted under normal or controlled abnormal conditions (refer to Section D.5.d) but must be significant per Section C.2.a of Appendix D. (*) Reactivity and normal evolutions may be replaced with additional instrument or component malfunctions on a 1-for-1 basis.

3. Whenever practical, both instrument and component malfunctions should be included; only those that require verifiable actions that provide insight to the applicants competence count toward the minimum requirements specified for the applicants license level in the right-hand columns.

ES-301 Transient and Event Checklist Form ES-301-5 Facility:

Date of Exam:

Operating Test No.:

Scenarios 1

2 3

4 CREW POSITION CREW POSITION CREW POSITION CREW POSITION M

I N

I M

U M(*)

A P

P L

I C

A N

T E

V E

N T

T Y

P E

S R

O A

T C

B O

P S

R O

A T

C B

O P

S R

O A

T C

B O

P S

R O

A T

C B

O P

T O

T A

L R

I U

RX 1

1 0 NOR 1

1 1 1 I/C 5

4 4 2 MAJ 1

2 2 1 RO SRO-I SRO-U X

TS 2

0 2 2 RX 1

1 0 NOR 1

1 1 I/C 4

4 2 MAJ 2

2 1 RO SRO-I SRO-U TS 0

2 2 RX 1

1 0 NOR 1

1 1 I/C 4

4 2 MAJ 2

2 1 RO SRO-I SRO-U TS 0

2 2 RX 1

1 0 NOR 1

1 1 I/C 4

4 2 MAJ 2

2 1 RO SRO-I SRO-U TS 0

2 2 Instructions:

5.

Check the applicant level and enter the operating test number and Form ES-D-1 event numbers for each event type; TS are not applicable for RO applicants. ROs must serve in both the at-the-controls (ATC) and balance-of-plant (BOP) positions; Instant SROs must serve in both the SRO and the ATC positions, including at least two instrument or component (I/C) malfunctions and one major transient, in the ATC position. If an Instant SRO additionally serves in the BOP position, one I/C malfunction can be credited toward the two I/C malfunctions required for the ATC position.

6.

Reactivity manipulations may be conducted under normal or controlled abnormal conditions (refer to Section D.5.d) but must be significant per Section C.2.a of Appendix D. (*) Reactivity and normal evolutions may be replaced with additional instrument or component malfunctions on a 1-for-1 basis.

3. Whenever practical, both instrument and component malfunctions should be included; only those that require verifiable actions that provide insight to the applicants competence count toward the minimum requirements specified for the applicants license level in the right-hand columns.

ES-301 Transient and Event Checklist Form ES-301-5 Facility:

Date of Exam:

Operating Test No.:

Scenarios 1

2 3

4 CREW POSITION CREW POSITION CREW POSITION CREW POSITION M

I N

I M

U M(*)

A P

P L

I C

A N

T E

V E

N T

T Y

P E

S R

O A

T C

B O

P S

R O

A T

C B

O P

S R

O A

T C

B O

P S

R O

A T

C B

O P

T O

T A

L R

I U

RX 1

1 0 NOR 1

1 1 I/C 4

4 2 MAJ 2

2 1 RO SRO-I SRO-U TS 0

2 2 RX 1

1 0 NOR 1

1 1 I/C 4

4 2 MAJ 2

2 1 RO SRO-I SRO-U TS 0

2 2 RX 1

1 0 NOR 1

1 1 I/C 4

4 2 MAJ 2

2 1 RO SRO-I SRO-U TS 0

2 2 RX 1

1 0 NOR 1

1 1 I/C 4

4 2 MAJ 2

2 1 RO SRO-I SRO-U TS 0

2 2 Instructions:

7.

Check the applicant level and enter the operating test number and Form ES-D-1 event numbers for each event type; TS are not applicable for RO applicants. ROs must serve in both the at-the-controls (ATC) and balance-of-plant (BOP) positions; Instant SROs must serve in both the SRO and the ATC positions, including at least two instrument or component (I/C) malfunctions and one major transient, in the ATC position. If an Instant SRO additionally serves in the BOP position, one I/C malfunction can be credited toward the two I/C malfunctions required for the ATC position.

8.

Reactivity manipulations may be conducted under normal or controlled abnormal conditions (refer to Section D.5.d) but must be significant per Section C.2.a of Appendix D. (*) Reactivity and normal evolutions may be replaced with additional instrument or component malfunctions on a 1-for-1 basis.

3. Whenever practical, both instrument and component malfunctions should be included; only those that require verifiable actions that provide insight to the applicants competence count toward the minimum requirements specified for the applicants license level in the right-hand columns.

Appendix D Scenario Outline Form ES-D-1 Facility: Cooper Nuclear Station Scenario No.: NRC 1 Op-Test No.: _______

Examiners: ____________________________ Operators:

Initial Conditions: The plant is operating at 8% power with a startup in progress.

Turnover: Raise power and put the main turbine on line. Rod 22-27 has been inserted from 48 to 46 to return temperatures back into the normal band.

Event No.

Malf.

No.

Event Type*

Event Description 1

R Raise power to get 50% bypass valve position 2

1 I

Torus Level Instrument Fails Upscale 3

2 C

Difficult to move Control Rod 4

3 N

Role the Turbine 5

4 C

TEC Pump Trip 6

5 C

Single MSIV Inadvertent Closure 7

6 C

Rod Drop Accident 8

7 M

Fuel Failure/Scram/Failure of Scram discharge volume drain valve to close.

9 8

C Group 6 isolation failure (N)ormal, (R)eactivity, (I)nstrument, (C)omponent, (M)ajor

Appendix D Scenario Outline Form ES-D-1 Facility: Cooper Nuclear Station Scenario No.: NRC 2 Op-Test No.: 2009 NRC Examiners: ____________________________ Operators:

Initial Conditions: Near End of Operating Cycle 95% power and raising power to 100%. EDG 1 running unloaded for break-in run after maintenance that replaced 1 piston.

Turnover: Continue EDG 1 synch and load per procedure. Continue raising power to rated power.

EDG 1 LCO due to maintenance.

Event No.

Malf.

No.

Event Type*

Event Description 1

N Synchronize and Load EDG 1 per procedure.

2 R

Raise Power with RR to rated power 3

1 C

HPCI inadvertent Initiation 4

2 C

Condensate Pump A Trip, A RR Pump Fails to run back 5

3 I

APRM B fails at 100%

6 4

M Main turbine vibration increase resulting in Turbine Trip Required, Reactor Manual Scram (ATWS no rods move) 7 5

M Non Critical Busses fail to fast transfer on Turbine Trip 8

6 C

SLC Pump A starts then trips immediately 9

7 I

RCIC Flow Controller Fails Low must be taken to manual 10 8

C RCIC Turbine Trip (N)ormal, (R)eactivity, (I)nstrument, (C)omponent, (M)ajor

Appendix D Scenario Outline Form ES-D-1 Facility: Cooper Nuclear Station Scenario No.: _NRC 3_______

Op-Test No.: _______

Examiners: ____________________________ Operators:

Initial Conditions: The plant is operating at 75% power near the end of the current fuel cycle. CBP B is being restored to service following corrective maintenance. It is a red light day and the dispatcher has requested that power be raised to maximum. SLC pump 1A is out of service to replace the discharge relief valve.

Turnover: Crew is to Start CBP B and continue power ascension. TS for SLC pump LCO is included.

Event No.

Malf.

No.

Event Type*

Event Description 1

N Start Condensate Booster Pump B 2

R Raise Power using RR 3

1 I

RRMG A controller failure to maximum 4

2 C

Loss RCIC 125 VDC 5

3 M

Lowering Main Condenser Vacuum resulting in Scram and Turbine trip Required 6

R Emergency Power reduction to maintain Vacuum 7

4 C

When Reactor is Scrammed both Reactor Feed pumps trip 8

5 M

When turbine tripped Loss of Offsite power occurs. EDG #2 fails to start and can not be started from the Control room and 4160F lock out occurs due to a fault on the bus. This results in a Station black Out.

9 6

C HPCI oil system fails (leak) resulting in HPCI unavailable to inject to RPV (N)ormal, (R)eactivity, (I)nstrument, (C)omponent, (M)ajor

Appendix D Scenario Outline Form ES-D-1 Facility: Cooper Nuclear Station Scenario No.:

NRC 4 (SPARE)

Op-Test No.:

Examiners:

Operators:

Initial Conditions: The plant is operating at 90% power with no equipment out of service.

Turnover: After the crew has assumed the watch, Start 1B CRD Pump and secure 1A CRD Pump to allow maintenance on the motor.

Event No.

Malf.

No.

Event Type*

Event Description

1.

N Swap CRD Pumps

2.

1 C

RCIC Steam Leak and Manual Isolation of RCIC

3.

2 I

Oscillating Feedwater Flow Instrument

4.

3 C

Condensate booster pump trip

5.

R Emergency Power Reduction

6.

4 C

A Reactor Recirc Pump Trip

7.

5 C

Reactor Recirc Pump Seal Failure

8.

6 M

Large LOCA

9.

7 C

Core Spray Valves Fail to Auto Open

10.

8 C

RHR pumps fail to Auto Start

11.

M Emergency Depressurization due to low level.

(N)ormal, (R)eactivity, (I)nstrument, (C)omponent, (M)ajor