ML100740176
| ML100740176 | |
| Person / Time | |
|---|---|
| Site: | Oyster Creek |
| Issue date: | 05/31/2009 |
| From: | Conestoga-Rovers & Associates |
| To: | Office of Information Services |
| References | |
| FOIA/PA-2009-0214 | |
| Download: ML100740176 (52) | |
Text
.ESTIMATED MASS FLUX OF TRITIATED GROUNDWATER TO THE INTAKE & DISCHARGE CANALS OYSTER CREEK GENERATING STATION FORKED RIVER, NEW JERSEY Prepared For:
Exelon Generation Company, LLC MAY 2009 REF. NO. 055875 (2)
TABLE OF CONTENTS
1.0 INTRODUCTION
1 2.0 SC O PE O F W O R K..................
...... 2
3.0 BACKGROUND
4 3.1 STATION LOCATION.................................................................................
4 3.2 MONITORING WELL NETWORK............................................................
4 3.2.1 2009 ADDITIONAL MONITORING WELL INSTALLATION...............
4 3.3 SURROUNDING LAND USE.....................................................................
5 3.4 TOPOGRAPHY AND SURFACE WATER FEATURES............................
5 3.5 G E O L O G Y.....................................................................................................
.. 7 3.5.1 REGIONAL GEOLOGY...............................................................................
7 3.5.2 STATION GEOLOGY....................................................................................
7 3.5.3 GEOLOGY IN THE VICINITY OF THE CST............................................
9 3.6 HYDROGEOLOGY AND GROUNDWATER FLOW.............................
11 3.6.1 REGIONAL HYDROGEOLOGY.............................................................
.. 11 3.6.2 STATION HYDROGEOLOGY...................................................................
11 3.6.3 HYDROGEOLOGY NEAR THE CST........................................................
13 3.7 AQUIFER CHARACTERIZATION..........................................................
15 3.8 GROUNDWATER FLOW RATE..............................................................
15 3.9 SOURCE AREA DISCUSSION.................................................................
16 3.10 DISTRIBUTION OF TRITIUM....................................................................
17 3.10.1 TRITIUM DISTRIBUTION - PRIOR TO APRIL 2009............................ 17 3.10.2 TRITIUM DISTRIBUTION - APRIL THROUGH MAY 2009.................
17 3.10.3 TRITIUM PLUMES......................................................................................
17 4.0 MASS FLUX CALCULATION RESULTS....................................................................
21 4.1 METHODOLOGY........................................................................................
21 4.2 R E SU L T S.....................................................................................................
.. 22 5.0 R E F E R E N C E S........................................................................................................................
25 055875 (2) Oyster Creek Generating Station CONESTOGA-ROVERS & ASSOCIATES
LIST OF FIGURES FIGURE 1 STATION LOCATION MAP FIGURE 2 STATION BOUNDARIES AND FEATURES
.FIGURE 3 STATION MAP AND MONITORING WELL LOCATIONS FIGURE 4 MAP OF CST LOCATION AND CROSS-SECTION LOCATIONS FIGURE 5 GEOLOGIC CROSS-SECTION A-A' FIGURE 6 GEOLOGIC CROSS-SECTION B-B' FIGURE 7 GEOLOGIC CROSS-SECTION C-C' FIGURE 8.
POTENTIOMETRIC SURFACE CONTOURS CAPE MAY FORMATION - APRIL 28, 2009 - ENTIRE SITE FIGURE 9 POTENTIOMETRIC SURFACE CONTOURS CAPE MAY FORMATION - APRIL 28, 2009 - AREA OF CONCERN.
FIGURE 10 POTENTIOMETRIC SURFACE CONTOURS COHANSEY FORMATION - APRIL 28, 2009 - ENTIRE SITE FIGURE 11 POTENTIOMETRIC SURFACE CONTOURS COHANSEY FORMATION - APRIL 28, 2009 - AREA OF CONCERN FIGURE 12 POTENTIOMETRIC SURFACE CONTOURS KIRKWOOD FORMATION - APRIL 28, 2009 - ENTIRE SITE FIGURE 13 HYDROGEOLOGIC CROSS-SECTION A-A' FIGURE 14 HYDROGEOLOGIC CROSS-SECTION B-B' FIGURE 15 TRITIUM CONCENTRATIONS FIGURE 16 CAPE MAY FORMATION ISOCONCENTRATION MAP FIGURE 17 ISOCONCENTRATION CROSS-SECTION A-A' FIGURE 18 ISOCONCENTRATION CROSS-SECTION B-B' FIGURE 19 LINE OF SECTIONS FOR MASS FLUX CALCULATIONS 055875 (2) Oyster Creek Generating Station H
CONESTOGA-ROVERS & ASSOCIATES
LIST OF TABLES TABLE 1
SUMMARY
OF EXISTING MONITORING WELL INFORMATION TABLE 2
SUMMARY
OF GROUNDWATER ELEVATION DATA TABLE 3
SUMMARY
OF SURFACE WATER ELEVATION DATA TABLE 4
SUMMARY
OF CALCULATED VERTICAL HYDRAULIC GRADIENTS AT WELL CLUSTER LOCATIONS TABLE 5
SUMMARY
OF AQUIFER TESTING DATA TABLE 6
SUMMARY
OF TRITIUM DATA TABLE 7 MASS FLUX CALCULATIONS LIST OF APPENDICES APPENDIX A WELL LOGS 055875 (2) Oyster Creek Generating Station iii CONESTOGA-ROVERS & ASSOCIATES
1.0 INTRODUCTION
This report presents the results of Mass Flux Calculations prepared for the Exelon Generation Company, LLC (Exelon) in regard to the Oyster Creek Generating Station (Station). Previous investigations at the Station include a Hydrogeologic Investigation Report (HIR) (CRA, 2006) and semi-annual monitoring/sampling of the tritium monitoring network as part of Exelon's Groundwater Protection Program.
Conestoga-Rovers & Associates (CRA) prepared this Mass Flux Calculations Report to estimate the tritium concentrations that may be migrating in groundwater to the Intake and Discharge Canals.
This report cites the results of CRA's May 2006 Hydrogeologic Investigation Work Plan (Work Plan) and the September 2006 HIR. Additional resources used in preparation of this document include:
- Routine Groundwater and Surface Water Monitoring Round Reports, AMO Environmental Decisions, Fall 2006 through Fall 2008.
" Routine Groundwater and Surface Water Monitoring Round Data, AMO Environmental Decisions, Spring 2009.
- Personal communication with Exelon and Station personnel.
- Station documentation including construction drawings of pertinent structures.
- CRA's April 2009 Scope of Work - Investigative Activities.
- Summary of monitoring well and staff gauge installation activities.
- Survey data of monitoring wells and staff gauge monitoring points.
- Synoptic groundwater and surface water elevation data.
- Station-provided groundwater and surface water analytical data.
055875 (2) Oyster Creek Generating Station 1
CONESTOGA-ROVERS & AssocIATES
2.0 SCOPE OF WORK This section presents the scope of work completed to calculate the flux of tritium into the Intake and Discharge Canals. CRA completed five preliminary tasks to support the calculations:
Geologic and hydrogeologic cross-sections were created between the Turbine Building/CST and the Intake/Discharge Canals. These cross-sections were used to evaluate the geology and groundwater flow in the area of interest.
CRA evaluated various hydraulic parameters (e.g. hydraulic conductivity) from previous investigations during preparation for the mass flux calculations.
" Groundwater contour maps were developed for the overburden (Cape May and Cohansey) aquifers based on one synoptic, station-wide, water level measurement event completed on April 28, 2009.
0 Isoconcentration maps were created by contouring the maximum tritium groundwater concentrations observed in April 2009.
A hydrogeologic cross-section with isoconcentration contours was created along the shoreline of the Station (eastern shore of the Intake and Discharge Canals).
The section follows the "horseshoe" shape of the intake/discharge canals along the western portion of the Station.
In general, the section follows the groundwater elevation contours. By defining the section along a contour, the groundwater flow is perpendicular to the cross-section allowing the mass flux calculations.
CRA completed these seven tasks to complete the tritium mass flux estimate:
Subdivided the overburden aquifer (Cape May and Cohansey) into 30 segments (ranging from 50-feet to 200-feet wide).
Determined the thickness of the aquifer within each segment.
The saturated thickness of the Cape May is approximately 10 feet and the saturated thickness for the Cohansey is approximately 50 feet.
Determined the groundwater flow directions and hydraulic gradients from the groundwater contour maps.
The groundwater flow rate (Q) (in gallons per minute) for each segment was determined using the following form of Darcy's Law: Q = KiA where K is the hydraulic conductivity of the aquifer (ft/day), i is the horizontal hydraulic gradient in the direction of flow (dimensionless), and A is the cross-sectional area perpendicular to the direction of flow (square feet).
Determined the'average tritium concentration (C) for each segment from the isoconcentration cross-section. Where the tritium concentration was reported to be 055875 (2) Oyster Creek Generating Station 2
CONESTOGA-ROVERS & ASSOCIATES 055875 (2) Oyster Greek Generating Station 2
CONESTOGA-ROVERS & ASSOCIATES
less than the minimum detectable concentration (MDC), a background tritium concentration was used:
" Calculated the mass flux for tritium for each segment (Curies per year [Ci/yr]) using the formula: Mass flux = CQ.
- Added the mass flux for each segment to get the total mass flux of tritium to the Intake and Discharge canals.
The above seven steps were completed three times - once for the Cape May Formation/Fill and twice for the Cohansey Formation. The entire saturated Cape May Formation/Fill was considered one thickness equal to 10 feet; the Cohansey was subdivided into two equal vertical segments of 25-feet each.
CRA made five conservative assumptions in the mass flux calculations:
" Radioactive decay was ignored.
Elevated tritium concentrations were used as input for the mass flux calculations.
Some of these elevated tritium concentrations have not, and may never, reach the groundwater discharge points at the intake and discharge canals.
" Tritium concentrations were considered constant over time.
Based on available analytical and hydrogeology data, the Kirkwood Formation is not impacted by tritium and therefore was not considered in the mass flux considerations.
The mass flux results were estimated based on the procedures and data described in the above scope of work tasks. These procedures are clearly defined and were consistently followed to minimize the potential for bias.
Therefore, by following the defined procedures, different. investigators should arrive at the same mass flux values. The procedures are intended to provide a conservative estimate using a repeatable, simplified method based on the existing data and information.
055875 (2) Oyster CreeI Generating Station 3
CONESTOGA-ROVERS & ASSOCIATES 055875 (2) Oyster Creek Generating Station 3,
CONESTOGA-ROVERS & ASSOCIATES
3.0 BACKGROUND
This section presents an overview of the Station location and background information including a description of groundwater flow and tritium concentrations in groundwater.
3.1 STATION LOCATION Figure 1 shows the location of the Station and the surrounding area. The Station is on US Route 9 south in Forked River, New Jersey. The Station is divided into two parcels.
Parcel 1 and Parcel 2 are shown on Figure 2.
Parcel 1 consists of approximately 144 acres and is referred to as the developed portion of the Station. Figure 3 presents a map of Parcel 1. This area is west of Route 9 and is mostly contained within the "horseshoe" formed by the Intake and Discharge Canals.
Parcel 1 also includes approximately 12 acres located outside of the horseshoe along the south bank of Oyster Creek.
Parcel 2 consists of approximately 637 acres located to the east of Route 9 and is referred to as the former Finninger Farm Property.
This area is primarily vegetated and undeveloped. The Intake Canal flows from Barnegat Bay westward along the northern portion of Parcel 2, and the Discharge Canal flows eastward from the Station to Barnegat Bay along the southern portion of Parcel 2.
3.2 MONITORING WELL NETWORK Over the history of the Station numerous monitoring wells were installed for various purposes. In total, there are 69 monitoring wells at the Station. The monitoring wells are completed in the Cape May, Cohansey, and Kirkwood Formations. Figure 3 depicts the locations of the monitoring wells.
A summary of monitoring well construction details is provided in Table 1.
3.2.1 2009 ADDITIONAL MONITORING WELL INSTALLATION Between April 21 and 24, 2009, five groundwater monitoring wells (W-50 through W-54) were installed for the investigation related to the CST pipe leaks. All five monitoring wells were installed in the overburden (Cape May Formation) west of the Turbine Building, to a target depth of 20 feet bgs using the hollow-stem auger (HSA) drilling 055875 (2) Oyster Creek Generating Station 4
CONESTOGA-ROVERS & ASSOCIATES
method. Figure 4 shows the recently installed monitoring wells and previously installed monitoring wells near the CST pipe leaks. Monitoring well construction logs for wells MW-50 through MW-54 are provided in Appendix A.
A staff gauge was installed along the western portion of the Discharge Canal just south of the Intake Canal and designated surface water monitoring location SW-2.
The existing and new surface water monitoring locations are depicted on Figures 3 and 4.
On April 28, 2009, the five new monitoring wells along with 'several existing monitoring wells and new (SW-2) and existing (SW-1, North Bridge, and South Bridge) surface water monitoring locations (staff gauges) were surveyed by a licensed New Jersey surveyor to establish reference elevations relative to mean sea level. The measurement locations, top of each well casings, and ground elevations were surveyed to the nearest 0.01-foot relative to the North American Vertical Datum (NAVD) 1988.
The survey points were clearly marked for future reference. The locations of the surface water measurement locations and monitoring well locations were surveyed to the nearest 0.10-foot relative to North American Datum (NAD) 1983. The monitoring well and staff gauge reference elevations and measurements are presented in Tables 2 and 3, respectively.
3.3 SURROUNDING LAND USE The surrounding land use consists of mixed residential, commercial, and undeveloped property. To the north and east of the Station is mixed residential and commercial properties and marinas. The undeveloped Parcel 2 and Barnegat Bay are also located to the east of the Station.
To the south is mixed residential and commercial land.
Immediately to the west of the Station is a power generating plant owned by Jersey Central Power & Light (JCP&L)/First Energy, the Forked River Combustion Turbine facility, and further west beyond this facility are undeveloped land and the Garden State Parkway.
3.4 TOPOGRAPHY AND SURFACE WATER FEATURES The Station is located in the Atlantic Coastal Plain physiographic province.
The topography in the region is characterized by a slight, undulating coastal plain having low relief. The land surface gradually rises from sea level at Barnegat Bay, which is east of the Station, to approximately 50 feet above mean sea level (AMSL) two miles inland.
055875 (2) Oyster Creek Genereting Station 5
CONESTOGA-ROVERS & AssociATEs 055875 (2) Oyster Creek Generating Station 5
CONESTOGA-ROVERS & ASSOCIATES
This region of the coastal plain has numerous tidal marshes and is incised by easterly flowing streams and creeks [United States Geological Survey (USGS), Quadrangle Map].
Elevations at the Station property west of Route 9 range from approximately 0 to 15 feet AMSL immediately adjacent to the Intake and Discharge Canals to slightly more than 30 feet AMSL in the northwest portion of the Station property. The 132-acre developed portion of the Station located within the "horseshoe" west of Route 9 has an average elevation of 20 feet AMSL. In the immediate vicinity of the major Station structures, the topography slopes steeply down to the Intake and Discharge Canals.
The remaining 637-acre portion of the, Station located east of Route 9 is primarily vegetated and undeveloped. The ground surface is relatively level except for the steep slopes at areas adjacent to the Intake and Discharge Canals.
The Station is located approximately 10,000 feet west of the confluence of Forked River and Barnegat Bay, which flows into the Atlantic Ocean. Oyster Creek is located south and west of the Station, and flows into the Discharge Canal directly south of the Station.
Oyster Creek is dammed upstream of the Discharge Canal, creating an impoundment (a.k.a. Fire Pond) that serves as a source of surface water for fire protection.
The mean tidal range at the mouth of Oyster Creek is approximately 0.5 feet (Kennish and Lutz, 1984). Portions of the lower reach of Oyster Creek were excavated to form the Discharge Canal. Therefore, the mouth of Oyster Creek and the outlet of the Discharge Canal are the same feature. The mouth of Forked River is located in Barnegat Bay approximately 5,000 feet north of the mouth of Oyster Creek.
Therefore, the tidal influence at the mouth of the Forked River would be expected to be similar to that at Oyster Creek.
The Intake Canal, which is the source of cooling water for the Station, wasconstructed by enlarging an existing tributary of the Forked River and reversing its flow. The Intake Canal is approximately 9,000 feet long and flows westerly along the northern portion of the Station property toward the intake structure. Approximately 476,000 gallons per minute (gpm) of water are withdrawn from the Intake Canal for Station use (NRC, 2007).
The Discharge Canal is located south of the Station and drains to Barnegat Bay. The Discharge Canal is approximately 11,000 feet long and flows easterly along the southern portion of the Station away from the discharge point. Three dilution-water pumps on the western side of the Intake Canal pump water directly from the Intake Canal to the Discharge Canal to provide cooling water to normal station discharge water. The dilution-water pumps have a pumping capacity of 260,000 gpm; however, only two of the three pumps operate concurrently for a typical discharge rate to the Discharge Canal 055875 (2) Oyster Creek Generating Station 6
CONESTOGA-ROVERS & ASSOCIATES
of 520,000 gpm (NRC, 2007). Therefore, the total amount of water taken by the Station from the Intake Canal and discharged to the Discharge Canal is approximately 1 million gpm of water to the Discharge Canal.
3.5 GEOLOGY 3.5.1 REGIONAL GEOLOGY The regional stratigraphy beneath the Atlantic Coastal Plain is composed of a thick wedge of gently seaward-dipping (southeast) horizontal beds of clay, sand, and gravel.
These deposits range in thickness from approximately 1,000 feet in the northern portion of the county to approximately 4,000 feet in the southern part of the county. These thick wedges of clastic sediments are unconformably underlain by early Paleozoic or Pre-Cambrian metamorphosed bedrock.
Additional details of regional geology are provided in the HIR (CRA, 2006).
3.5.2 STATION GEOLOGY In descending order, the following six stratigraphic units have been identified and characterized during prior investigations at the Station:
Fill;
- Cape May Formation,
- upper clay; Cohansey Formation;
- lower clay; and
- Kirkwood Formation.
The descriptions of these units are presented below and are based largely on the interpretations and boring logs presented in reports related to previous Station investigations which are referenced in Section 5.0.
Fill The fill is a tan, medium-to fine-grained sand, with trace to some silt. Based on the descriptions, a substantial portion of the fill material appears to consist of Cape May Formation deposits relocated during Station construction activities. The thickness of fill 055875 (2) Oyster Creek Generating Station CONESTOGA-ROVERS & AssocIATES
varies from 0 to 55 feet but typically ranges from 5 to 10 feet.
The maximum fill thickness is estimated to be approximately 55 feet in the immediate area of the Reactor Building due to construction excavation [URS Greiner Woodward Clyde (URSGWC),
2000)].
Cape May Formation The Cape May Formation is described as a light gray to tan, medium-to fine-grained sand, with trace to some silt and occasional coarse sand. The Formation is generally poorly compacted. At the Station, the Cape May Formation ranges in thickness from 0 to 21 feet, primarily due to the varying amount of material excavated and replaced by fill during Station construction.
The base of the Cape May Formation generally is defined by the presence of a dark clay unit, referred to in Station reports as the upper clay unit [WCC, 1984].
Upper Clay The upper clay is a stiff to hard, gray, plastic organic clay containing inclusions (also described as lenses or partings) of dense fine-grained sand with trace to some organic silt. The deposits of fine-grained sand within the upper clay layer have high relative densities and occur as lenses or inclusions. Some boring logs identify these lenses as the dominant feature in 1-to 5-foot intervals within the upper clay unit.
In the area southwest of the Turbine Building, approximately half of the total thickness of the upper clay is silty sand. The, upper clay is present at an approximate depth of 20 feet below grade and is approximately 5 to 10 feet thick, except in areas where it has been removed or thinned by excavation during Station construction. For example, the clay has been breached beneath and immediately around the Reactor and Turbine Buildings. Between the Turbine Building and the Intake and Discharge Canals, the upper clay was removed during construction; however, an artificial clay layer (1.5-to 3-feet thick) was placed in this area at the same time (JCP&L, Drawing #4006-2). It is believed that this clay was constructed to minimize the need for dewatering during construction of the Intake/Discharge tunnels and other surrounding structures.
Therefore, the native upper clay is present over much of the Station, but is absent in some areas.
Cohansey Formation The Cohansey Formation underlies the Cape May Formation and is primarily composed of a light-colored, fine-to very coarse-grained quartzose sand with lenses of silt and 055875 (2) Oyster Creek Generating Station 8
CONESTOGA-ROVERS & ASSOCIATES
clay. The sands in the lower portion of the Cohansey Formation are more dense (as evidenced by higher blow counts during drilling) and distinguishable from the less dense sands in the upper portion of the unit. Although most borings at the Station do not penetrate the entire Cohansey Formation, this formation appears to be approximately 60 to 80 feet thick beneath the Station. A clay sequence, referred to at the Station as the "lower clay", marks the base of the Cohansey Formation, which generally is present at approximately 90 to 100 feet below ground surface (bgs) (NUREG-1427, Supplement 28).
Lower Clay The lower clay is a dense gray medium-to fine-grained sand containing trace to some organic silt and layers or inclusions of very stiff to hard gray organic clay. The thickness of the lower clay is estimated to be 10 to 20 feet (WCC, 1984).
Kirkwood Formation The Cohansey Formation is underlain by the Kirkwood Formation, which consists of several stratigraphic units. The Kirkwood Formation is described as a medium-to fine-grained sand with trace silt. The Kirkwood Formation ranges from a light gray to yellow-brown micaceous, ilmenitic, lignitic, very fine-to fine-grained quartz sand to coarse sand with some fine to coarse gravel. The Kirkwood thickness in Ocean County ranges from approximately 300 to 400 feet (WCC, 1977). The thickness of this formation beneath the Station is unknown. This unit is interbedded with thin clay units. Several sequences of clay 20 to 30 feet thick may be present within this unit.
The Station's north domestic supply well is completed in the Kirkwood Formation at a depth of 145 feet bgs. The Station's south domestic supply well is completed in the Kirkwood Formation at a depth of 310 feet bgs. The locations of the two supply wells are shown on Figure 3.
3.5.3 GEOLOGY IN THE VICINITY OF THE CST Figure 4 presents a map of the area near the CST and Intake/Discharge Canals. The figure also shows the lines of sections for geologic and hydrogeologic profiles. The geologic cross-sections are presented as Figures 5, 6 and 7. These sections were selected to provide cross-sectional views of the area of concern (CST), geology, subsurface structures, and the interface of the Intake and Discharge Canals.
055875 (2) OysterCreek Generating Station 9
CONESTOGA-ROVERS & ASSOCIATES 055875 (2) OysterCreek Generating Station 9
CONESTOGA-ROVERS & ASSOCIATES
Figure 5 presents a southwest-northeast (A-A') cross-section from the Discharge Canal to the CST. The geology consists of Fill underlain by the Cohansey Formation. A large portion of the central portion of the Station was excavated and re-contoured thereby removing the native Cape May Formation and portions of the upper clay and Cohansey Formation.
Excavations as deep as 50 feet were required for the completion the foundations of the Reactor Building and Turbine Building and up to 30 feet for the intake structure.
Fill was subsequently placed in these excavations and Station structures were then constructed. The Fill consisted of re-worked Cape May sand that was compacted during placement.
A relatively thin (1.5 to 3-foot) clay layer was installed to minimize the need for dewatering during construction.
Cross-section A-A' shows the following Station structures: the Turbine Building, CST, Intake/Discharge Tunnels, and Discharge Canal. The CST holds approximately 500,000 gallons of water and rests on a concrete ring with Fill immediately beneath the tank.
Several underground pipes connect the CST to other Station structures. Our review of the construction drawings and related reports indicate that the Intake Tunnel was constructed immediately on top of the Discharge Tunnel with no intervening space between the two. Therefore, the Intake/Discharge tunnel structure is considered one continuous structure.
The Turbine Building and Intake/Discharge Tunnels are constructed into the Cohansey formation at bottom elevations of -13 feet AMSL and -16 feet AMSL, respectively.
The Discharge Canal extends to -21 feet AMSL into the Cohansey Formation.
Figure 6 presents a west-east (B-B') cross-section from the Intake Canal and Intake Structure to the Turbine Building. The B-B' cross-section line is positioned just north of the Intake/Discharge Tunnels. The geology consists of Fill underlain by the Cohansey Formation. The artificial clay layer is reportedly present beneath the Intake Structure; however, it is not known whether the clay layer extends to the Turbine Building. The Intake Structure is surrounded by concrete and extends from grade level to the artificial clay horizon at -12 feet AMSL.
Figure 7 presents a west-east (C'C') cross-section from the Intake Canal and Intake Structure to the Turbine Building. This cross-section is through the Intake/Discharge Tunnels. The Intake Tunnel (+15 to 0.5 feet AMSL) rests on top of the Discharge Tunnel (0.5 to -16 feet AMSL). The Intake Tunnel extends from the Turbine Building to the Intake Structure. Discharge Tunnel 1 extends from the Turbine Building approximately 125 feet to, the west, where it turns to the southwest and enters the Discharge Canal.
Discharge Tunnel 2 was constructed for Unit 2, which was never completed. Discharge Tunnel 2 is approximately 50 west of Discharge Tunnel 1. As a consequence of this 055875 (2) Oyster Creek Generating Station 10 CONESTOGA-ROVERS & ASSOCIATES
design, there is a gap occupied with Fill material from the north side of the tunnels to the south.
3.6 HYDROGEOLOGY AND GROUNDWATER FLOW 3.6.1 REGIONAL HYDROGEOLOGY The unconsolidated deposits underlying the New Jersey Coastal Plain comprise one interrelated aquifer that includes several aquifers and confining units. The individual formations may change in physical character and act as an aquifer in one area, but serve as a confining unit elsewhere; additionally, some formations are divided into several aquifers or confining units and adjacent formations may form a single aquifer or confining unit (NUREG-1437, Supplement 28).
Regionally, the Cape May And Cohansey Formations are unconfined units and form the water table aquifer. The Cape May and Cohansey Formations are considered to be hydraulically-connected water table aquifers (NUREG-1437, Supplement 28). However, locally the water table aquifer may contain confined beds, resulting in slightly artesian conditions. Regionally, the Kirkwood Formation is considered to be unconfined and hydraulically connected with the lower portion of the Cohansey Formation. Recharge to the Kirkwood Formation is principally by leakage from the water table aquifer in higher elevation inland areas.
On a regional scale, groundwater generally flows to the south-southeast toward the Atlantic Ocean, following the tfend of the coastal plain sedimentary bedding. Locally, groundwater flow in the unconfined water-table aquifer generally mimics the surface topography with flow from higher areas towards lower areas. Groundwater discharge provides the base flow to nearby surface water bodies (e.g., creeks, streams, and rivers) or to Barnegat Bay and the Atlantic Ocean (WCC, 1977). Groundwater flow can be influenced by tidal cycles, with greater influences exerted in areas more proximal to the Atlantic Ocean or major surface water bodies.
3.6.2 STATION HYDROGEOLOGY At the Station, the hydrogeology of Parcel 1 is influenced by six factors:
- the regional groundwater flow;
- the Intake and Discharge Canals; 055875 (2) Oyster Creek Generating Station 11 CONESTOGA-ROVERS & AssocIATES
" the presence of the native upper clay between the Cape May and Cohansey Formations over most of the site;
- the lack of upper clay immediately surrounding Station Structures due to excavation; particularly near the Turbine Building, Reactor Building and Intake and Discharge Canals; and
" the presence of a thin artificial clay between the Turbine Building and Intake/Discharge Canals that was placed during construction to minimize groundwater infiltration into the excavation and, thus, dewatering. The extent and integrity of this clay layer are not known.
- the relatively impermeable man-made groundwater flow barriers present on site (e.g. Intake Structure, Intake/ Discharge tunnels, utility conduits, etc.).
The water table under the Station is found in the unconsolidated deposits of the Cape May Formation and Fill.
The depth to groundwater typically is 10 to 15 feet bgs.
Figures 8 and 9 present contour maps of the Cape May Formation based on groundwater measurements collected on April 28, 2009. The construction of the Intake and Discharge Canals changed groundwater flow directions and increased the depth-to-water in the Cape May Formation by approximately six feet (WCC, 1984). The figures depict radial flow from. the central portion from the Station to the west, north, and south towards the Intake and Discharge Canals. These contours indicate that the Intake and Discharge Canals are the primary controlling influence on groundwater flow in the Cape May Formation.
Figure 8 shows an anomalous groundwater low point or depression north of the Reactor Building.
Figure 9 shows an anomalous groundwater high point or mounding northwest of the Turbine Building, near the Torus Water Storage Tank (TWST). A depression in the water table is noted east of the Diesel Generator Building due to the ongoing recovery well operations associated with a former diesel fuel release.
In addition, due to the abundance of pipelines and utility lines throughout the site, there is a possibility of Cape May groundwater flow being diverted into the pipeline or utility line itself, which could provide a preferential flow path for groundwater flow. Most of these underground structures are constructed above the water table and therefore, should have minimal affect on the shallow flow. However, deeper structures at and below the water table do exist.
The Cape May and Cohansey Formations are separated by the 10- to 15-foot thick upper clay, which was breached during construction.
This breach created an unimpeded hydraulic connection between the Cape May and Cohansey Formations near the Reactor 055675 (2) Oyster Creelr Generating Stetion 12 CONESTOGA-ROVERS & ASSOCIATES 055875 (2) Oyster Creek Generating Station 12 CONESTOGA-ROVERS & AssocIATES
and Turbine Buildings, which combined with the natural downward vertical gradient, promoted groundwater flow from the Cape May Formation to the Cohansey Formation.
Water level measurements from the well pairs screened in the Cape May and Cohansey Formations indicate that a downward vertical gradient exists across the Site. Table 4 presents a summary of vertical flow gradients at select well clusters. Vertical gradients are downward in general and strongest by the intake structure and northern unpaved area of the Station.
Figures 10 and 11 present groundwater contour maps of the Cohansey Formation based on groundwater level measurements collected on April 28, 2009. Groundwater flow in the Cohansey Formation flows radially away from a hydraulic high in the central portion of the horseshoe area toward the Intake and Discharge Canals. These flow patterns indicate Ihat, within the footprint of the Station, the flow of groundwater is primarily influenced by the Intake and Discharge Canals, which are receiving groundwater from the Cohansey Formation.
The underlying Kirkwood Formation reportedly extends to an estimated depth of 500 feet. The lower clay separates the Cohansey and Kirkwood Formations. Water level monitoring data indicate that the Kirkwood Formation is a confined aquifer beneath the Station and can be artesian. Artesian heads as high as 22 feet AMSL have been observed in the Kirkwood Formation (WCC, 1984).
Figure 12 presents a contour map of the Kirkwood Formation based on groundwater level measurements collected on April 28, 2009. The potentiometric surface contours for the Kirkwood Formation indicate easterly flow toward Barnegat Bay and the Atlantic Ocean, which is consistent with the regional groundwater flow direction. No station structures directly affect groundwater flow within the Kirkwood Formation.
3.6.3 HYDROGEOLOGY NEAR THE CST Figure 4 presents a map of the area of the CST and Intake/Discharge Canals. The figure also shows the lines of sections for geologic and hydrogeologic profiles.
The hydrogeologic cross-sections are presented as Figures 13 and 14.
Figure 13 presents a southwest-northeast (A-A') cross-section from the Discharge Canal to the CST. The figure includes the piezometric surface for the Fill and Cohansey Formation. Groundwater flow in the Fill on the west side of the Intake/Discharge Tunnels is to the southwest with discharge to the Discharge Canal. Groundwater flow in the Fill on the east side of the Intake/Discharge Tunnels is to the northwest (into the 055875 (2) Oyster Creek Generating Station 13 CONESTOGA-ROVERS & AssocIATES
page) towards the Intake Structure. The Intake/Discharge Tunnels act as a hydraulic barrier, preventing groundwater flow from the west to the east (and vice versa) with one exception: the gap between Discharge Tunnel 1 and 2.
Since the lateral extent of the artificial clay is unknown, some groundwater in the Cape May presumably flows downward into the Cohansey Formation around the more permeable Fill. This downward flow into the Cohansey Formation is more likely to occur in areas adjacent to the Turbine Building and Intake/Discharge Tunnels, where the native upper clay was extensively removed. The groundwater flow in the Cohansey Formation is from the northeast beneath the Reactor and Turbine Buildings to the southwest with discharge to the Discharge Canal.
Figure 14 presents a west-east (B-B') cross-section from the Intake Canal and Intake Structure to the Turbine Building. The figure includes the piezometric surface for the Fill and Cohansey Formation. Groundwater flow in the Fill is to the west towards the Intake Structure, where the concrete Intake Structure (with Sheet Piles) acts as a groundwater flow barrier. Groundwater flow is directed to the north around the Intake Structure and/or under the Intake Structure, and then west where it discharges to the Intake Canal. Where the native upper clay or clay fill layer is absent, groundwater may also flow downward into the Cohansey Formation and then to the west with discharge into the Intake Canal.
The Intake/Discharge Tunnels act as a barrier preventing groundwater flow from the north to the south with one exception (the gap between Discharge Tunnel 1 and 2).
Since the extent of the artificial clay is unknown, and there is a downward vertical gradient, some groundwater in the Cape May likely flows downward into the Cohansey Formation around the more permeable Fill that is adjacent to the Turbine Building and Intake/Discharge Tunnels. The groundwater flow in the Cohansey Formation is from the east beneath the Reactor and Turbine Buildings to the west with discharge into the Intake Canal.
Near the CST and Intake/Discharge Canals, the difference in hydraulic head between the overlying Fill and underlying Cohansey Formation implies that these are separate hydraulic units. However, there are no wells in the Cohansey Formation in this area to confirm the Cohansey piezometric headvalues.
055875 (2) Oyster Creek Genereting Stetion 14 CONESTOGA-ROVERS & ASSOCIATES 1
055875 (2) Oyster Creek Generating Station 14 CONESTOGA-ROVERS & ASSOCIATES
3.7 AQUIFER CHARACTERIZATION Table 5 summarizes the available station-specific hydraulic conductivity data. Based upon historical slug test data, the hydraulic conductivity of the Cape May Formation range from 9.50 to 28.51 feet per day with an average -value of 19.53 feet per day (WCC, 1984).
Results from prior aquifer pumping tests indicate that the hydraulic conductivity of the Cape May Formation is 1.00 feet per day (WCC, 1992). Based upon historical slug test data, the hydraulic conductivity values of the Cohansey range from 12.10 to 38.88 feet per day with an average value of 27.22 feet per day,(WCC, 1984).
3.8 GROUNDWATER FLOW RATE The horizontal groundwater flow velocity of the Cape May/Fill and Cohansey Formation was calculated in the area of concern using Darcy's Law:
V=KI/n where:
V horizontal groundwater velocity (length/ time)
K hydraulic conductivity (length/ time)
I hydraulic gradient (unitless) n effective porosity (unitless)
For the Cape May/Fill, the horizontal hydraulic gradient north and south of the Intake/Discharge Tunnels is 0.06 feet/foot and 0.10 feet/foot, respectively. Assuming an average effective porosity of 0.30 and using the calculated horizontal gradients, the average linear groundwater flow velocity in the Cape May is approximately 1,426 feet/year and 2,376 feet/year north and south of the Intake/Discharge Tunnels, respectively.
For the Cohansey Formation, the horizontal hydraulic gradient north and south of the Intake/Discharge Tunnels is 0.02 feet/foot and 0.01 feet/foot, respectively. Assuming an average effective porosity of 0.30 and using the calculated horizontal gradients, the average linear groundwater flow velocity in the Cohansey Formation is approximately 662 feet/year and 331 feet/year north and south of the Intake/Discharge Tunnels, respectively.
055875 (2) Oyster Creek Generating Station 15 CONESTOGA-ROVERS & ASSOCIATES 055875 (2) Oyster Creek Generating Station 15 CONESTOGA-ROVERS & AssocIATES
3.9 SOURCE AREA DISCUSSION Based upon 2006 HIR, CRA identified the following as Areas for Further Evaluation (AFEs):
AFE-Oyster Creek-i: Main Complex AFE-Oyster Creek-2: Condensate Storage Tank AFE-Oyster Creek-3: Torus Water Storage Tank AFE-Oyster Creek-4: Isolation Condenser Vents The area of concern for the current investigation includes AFE-2, which includes the CST and the pipes between the tank and the Turbine Building. The CST is west of the Turbine Building just north of the Intake Tunnel.
AFE-2 includes six systems as identified in the HIR:
225 - CRD 251 - Spent Fuel Pool Cooling 421 - Condensate 424 - Condensate Transfer System 523 - Demineralized Water
- 578 - Condensate Transfer'Building System Infiltration of water within a ESW vault located atop the Intake Tunnel was identified in April 2009. On April 15th, a sample of the water in the ESW vault indicated elevated concentrations of tritium. Subsequently, two leaks within the Condensate pipes (system
- 421) were identified. The leaks were identified in an 8-inch pipe and 10-inch pipe on April 25th and 27th, respectively. These leaks were repaired in April 2009. The exact rate and duration of the leaks are unknown. However, based on analytical data from nearby monitoring wells, the leak likely occurred after March 12, 2009.
This premise is supported in part by the fact that in March the tritium result in MW-15K-1A was LLD, and subsequent tritium results on April 17th (and subsequent samples in April and May) were above 2,000,000 pCi/L.
Depth to groundwater near the leaks is approximately 10 feet bgs for a corresponding groundwater elevation of 11.37 feet AMSL.
The west to east trending Intake and Discharge Tunnels are immediately south of the identified leaks. The top and bottom elevations of the Intake/Discharge Tunnels are 13 feet AMSL and -16 feet MSL, respectively. Typically, the tunnels would act as a hydraulic barrier to flow south of the leaks, however, tritium has been observed at elevated levels south of the tunnels. The occurrence of tritium south of the Intake/Discharge Tunnel structure implies that the 055875 (2) Oyster Creek Generating Station 16 CONESTOGA-ROVERS & AssocIATES
leak occurred at an elevation at or above the top of the structure in vadose zone and/or was possibly significant enough to create a temporary groundwater mounding effect. In the latter case, the water table would have to rise to an elevation of 15 ft ASML.
3.10 DISTRIBUTION OF TRITIUM 3.10.1 TRITIUM DISTRIBUTION - PRIOR TO APRIL 2009 As part of the Station's existing Groundwater Protection Initiative (GPI), semi-annual groundwater sampling events are completed for tritium analysis.
From May 2006 through March 2009, tritium was intermittently detected in groundwater at low levels (maximum 211 pCi/L). In the majority of the samples, tritium was not detected at concentrations greater than the LLD.
In all surface water samples, tritium was not detected above the LLD. Therefore, from May 2006 through March 2009 tritium mass flux to the Intake and Discharge Canals has essentially been zero.
Elevated tritium concentrations were detected in well MW-15K-1A at a concentration of 4,000,000 pCi/L in April 2009. The remainder of this section discusses tritium data collected in April through May 2009.
3.10.2 TRITIUM DISTRIBUTION - APRIL THROUGH MAY 2009 Figure 15 presents a summary of the tritium results for the groundwater and surface water samples collected from March 12 through May 6, 2009 at monitoring wells near the CST and surface water locations. Table 6 presents the tritium analytical results for the April/May 2009 CST investigation sampling. Tritium concentrations in the Cape May exceeded the LLD in six monitoring wells (W-5, W-50, W-51, W-53, W-54, and MW-15K-1A). The tritium concentrations in groundwater ranged from 326 pCi/L (W-5) to 6,050,000 pCi/L (W-51). Tritium was not detected at concentrations greater than the LLD in any of the surface water samples (Intake and Discharge Canals) collected during the March through May 2009 sampling events.
3.10.3 TRITIUM PLUMES Figure 16 presents an isoconcentration map of the distribution of tritium in the Cape May Formation. Figures 17 and 18 present isoconcentration cross-sections along A-A' 055875 (2) Oyster Creek Generating Station 17 CoNEsToGA-RovERs & AssocIATEs 055875 (2) Oyster Creek Generating Station 17 CONESTOGA-ROVERS & AssocIATES
and B-B', respectively. These figures are based on the maximum tritium groundwater concentrations detected during sampling activities completed in 2009.
Review of the tritium isoconcentration maps and cross-sections reveals four separate tritium plumes in the area of concern:
- Cape May/Fill plume south of tunnels;
- Cape May/Fill plume north of tunnels;
- Cape May/Fill plume north of ESW vault; and
- Cohansey plume.
Cape May/Fill plume south of tunnels Well MW-15K-1A southwest of the CST leak has exhibited tritium concentrations of greater than 5,000,000 pCi/L. This well is on the south side of the Intake/Discharge Tunnels, which act as a barrier to groundwater flow to the south (except through a "window" between Discharge Tunnels 1 and 2). Therefore, it is likely that the leak water mounded on top of the Intake/Discharge Tunnels and "spilled over" to the south where it entered the Cape May and migrated toward MW-15k-lA. Based on a review of the Cape May contour map this water likely continues to migrate to the southwest with discharge to the Discharge Canal. This scenario is supported, in part, by the increasing tritium concentrations in monitoring well MW-53 (LLD [April 25th], 9,000 pCi/L [April 29th], 13,100 pCi/L [May 1st], 15,100 pCi/L [May 6th]). This southern plume may also migrate to the west towards the Intake Canal as evidenced by tritium concentrations in well MW-54 (9,500 pCi/L [May 6th]). Although it is more likely that elevated tritium concentrations in MW - 54 are from a separate source (see Cape May/Fill plume north of vault plume).
Cape May/Fill plume north of tunnels Wells MW-50 and MW-51 near the CST pipe leaks have exhibited tritium concentrations of greater than 5,000,000 pCi/L. These wells are immediately downgradient of the two known leaks. The tritiated-leak water migrated vertically downward to the Cape May and west towards the Intake Structure. This northern plume is presumably forced to the west due to the Intake/Discharge Tunnels to the immediate south, which act as a hydraulic barrier to groundwater flow. As the plume migrates to the west, it can move to the south through the "window" between Discharge Tunnels 1 and 2. In addition, the plume can continue to migrate toward the Intake Structure, where it is either forced to 055875 (2) Oyster Greet Generating Station 18 CoNEsToGA-RovERs & AssocIATEs 055875 (2) Oyster Creek Generating Station 18 CONESTOGA-ROVERS & AssocIATES
flow north around the Intake Structure or downward into the Cohansey Formation. The latter scenario is more likely if the artificial clay fill layer has been breached.
Cape May/Fill plume north of ESW vault A tritium concentration of 7,950 pCi/L was detected in well MW-54 west of the ESW vault where tritium was first detected on April 15, 2009 at an elevated concentration of 136,000 pCi/L. The water in the vault likely accumulated in the vault by migrating along the electrical tunnel on top of the Intake/Discharge Tunnels. After an elevated detection of tritium in the vault, the water was pumped out. Tritium detected in well MW-54 may be from water leaking out of the ESW vault.
Cohansey plume Based on the groundwater flow and hydrogeologic cross-sections, it appears that the artificial clay fill layer serves as an aquitard between the Cape May and underlying Cohansey aquifer. However, the extent and integrity of the clay fill layer are not known.
Furthermore, there are no hydraulic and analytical data for the Cohansey Formation in the area of concern. Therefore, it is possible that some tritiated-water from the CST pipe leaks has migrated vertically downward into the Cohansey (likely around the Turbine building and Intake Structure).
To be conservative, CRA assumed that some tritiated-water has migrated vertically downward into the Cohansey Formation, as shown on the hydrogeologic cross-sections A-A' and B-B' (Figures 17 and 18). The Cohansey plume would migrate westward in the shallow Cohansey aquifer (top 25 feet) with eventual discharge to the Intake Canal.
Deeper groundwater in the bottom two-thirds of the aquifer (35 feet) is unlikely impacted since groundwater gradients in the Cohansey Formation are upward into the canals.
Summary At least two tritium plumes have resulted from recent CST pipe leaks near the CST tank.
These leaks were above the water table and mounded on top of the Intake/Discharge Tunnels and water table. Tritium plumes have resulted from these leaks. The plumes migrate primarily in the Cape May westward with discharge to the Discharge and Intake Canals. There may be a tritium plume may exist in the Cohansey Formation due to vertical downward migration from the Cape May, but a significant plume is not considered as likely since an artificial clay layer installed during construction of the Station minimizes downward groundwater' flow.
A Cohansey plume would also 055875 (2) Oyster Creek Generating Station 19 CONESTOGA-ROVERS & ASSOCIATES
migrate to the west and discharge to the Intake and Discharge Canals. It is unlikely that the Kirkwood Formation, which is separated from the Cohansey by a regional clay layer
('lower clay') is impacted by the tritiated water.
055875 (2) Oyster Creek Generating Station 20 CONESTOGA-ROVERS & ASSOCIATES
4.0 MASS FLUX CALCULATION RESULTS The work tasks that were required to complete the tritium mass flux estimate and results are presented in this section. For purpose of providing the most conservative mass flux estimate, the mass flux calculation used the maximum tritium concentrations recorded from the three sampling events.
4.1 METHODOLOGY The work tasks that were required to complete the tritium mass flux estimate are summarized below:
- Create a hydrogeologic cross-section with isoconcentration contours along the western shoreline of the Intake and Discharge Canals.
The section follows the groundwater elevation contours.
By defining the section along a contour, the groundwater flow is, perpendicular to the cross-section allowing the mass flux calculations. Figure 19 presents the line of section.
" Subdivide the aquifer into segments (ranging from 50-feet to 200-feet. A summary of the segment dimensions and.areas is presented in Table 7).
" Determine the thickness of the aquifer within each segment.
The saturated thicknesses of the Cape May and Cohansey Formations are approximately 10 and 50 feet, respectively.
" Determine the groundwater flow direction and hydraulic gradient for each segment from the groundwater contour maps.
- Determine the groundwater flow rate (in gpm) for each segment.
- Determine the tritium concentration for each segment.
The calculated average concentrations include background tritium concentrations where applicable: CRA assumed a conservative background concentration of 175 pCi/L based on an average method detection concentration of 149.1 in the Fall of 2008 for both the Cape May and the Cohansey groundwater samples (AMO, 2008).
- Calculate the mass flux for tritium for each segment in Ci/yr.
- Added together the mass fluxes for each segment to get the total mass flux.
- Subtract the background tritium concentration of 175 pCi/L to get the true mass flux.
055875 (2) Oyster Creek Generating Station 21 CONESTOGA-ROVERS & ASSOCIATES
4.2 RESULTS Table 7 presents the results of the mass flux calculations including an estimate of groundwater flow, tritium mass flux (Ci/yr), and tritium concentration (pCi/L) into the Intake and Discharge Canals.
The following documents the uncertainty associated with the mass flux calculations:
Hydraulic conductivity generated from slug tests completed in the Cape May and Cohansey Formations at the Station were used as input. However, without aquifer tests in the immediate vicinity of the area of concern there is uncertainty in these input values.
The input tritium concentrations for the Cohansey Formation were assumed to be 1/10th of the tritium concentrations in the overlying Cape May/Fill with the exception of the north plume near the Intake Structure.
All tritium input concentrations for the Cohansey Formation are rough estimates as no empirical data in the area of concern exists.
The input tritium concentrations for the Cape May/Fill were assumed to be on the order of the groundwater concentrations detected in monitoring wells near the CST leak (MW-50/MW-51: >=2,000,000 pCi/L). Tritium concentrations at these values currently are not discharging (and may never discharge) to the canals.,
This assumption was made in order to be conservative, and with the expectation that such concentrations may occur in the future as the plume migrates and discharges into the canals.
The tritium concentrations discharging to the canals are constant over time.
As noted above, the input concentrations have not reached the canals as of the time of this report. Furthermore, if the leak(s) have been stopped,.then tritium that reaches the canals will not be constant (i.e., a "slug" of tritium will reach the canals and then tritium concentrations will decline).
Therefore, the assumption of a continuous, elevated source of tritium (assuming all leaks have been identified and fixed) is conservative.
The Cape May/Fill and Cohansey Formations have been assumed to be of constant thickness over the entire length of the Discharge Canal and Intake Canals. This assumption is believed to be relatively accurate and conservative.
The Cohansey Formation, which is approximately 50 feet thick in the area of concern, has been divided into two segments each 25-feet thick. All groundwater from the Cohansey Formation has been assumed to discharge to the canals. It is possible that the deeper Cohansey Formation.groundwater flows to the east-southeast and does not discharge to the canals.
055875 (2) Oyster Creek Generating Station 22 CONESTOGA-ROVERS & ASSOCIATES
Groundwater Flow Table 7 presents a summary of the groundwater flow off the Station. This is the sum of the flows through each rectangle.
The following table summarizes the estimated groundwater flow conditions at the Station.
j~Description
~
Gro~undwrater Flowe gpm;<
Intake Canal Cape May/Fill 90 Cohansey Formation 102 SUBTOTAL 193 Discharge Canal Cape May/Fill 40 Cohansey Formation 110 SUBTOTAL 151 TOTAL FLOW 343 Notes:
Groundwater flow into the Intake Canal is pulled into the Station through the Intake Pumps.
Mass Flux in Cilyr Table 7 presents the results of the mass flux calculations in Ci/yr. The table presents the amount of tritium that discharges to surface water (Intake Canal and Discharge Canal) through the Cape May/Fill and Cohansey Formations. In addition, Table 7 shows the cumulative mass flux. The following table summarizes the estimated tritium discharge by flow zone and discharge point.
~iDescription ~,Tritium (Ci/yr)~
Intake Canal Cape May/Fill 0.31 Cohansey Formation 32.10 SUBTOTAL 32.41 Discharge Canal Cape May/Fill 32.13 Cohansey Formation 1.04 SUBTOTAL 33.17 TOTAL FLOW 65.58 055875 (2) Oyster Creek Generating Station 23 CONESTOGA-ROVERS & ASSOCIATES 055875 (2) Oyster Creek Generating Station 23 CONESTOGA-ROVERS & ASSOCIATES
Notes:
Tritium that discharges into the Intake Canal is pulled into the Station through the Intake Pumps.
Including the tritium contribution from background, CRA estimates that a total of 32.41 Ci/yr of tritium is flowing from the groundwater to the Intake Canal, with 33.17 Ci/yr of tritium flowing to the Discharge Canal.
To assess a true tritium mass flux discharge off the Station, as related to plant operations, it is necessary to subtract the contribution from background. As such, CRA estimates that the background tritium concentrations in groundwater are approximately 175 pCi/L. By subtracting the tritium mass contribution from background from the total tritium mass (0.12 Ci/yr); CRA calculated that a total of 65.46 Ci/yr of tritium mass is flowing from groundwater into the canal system.
The following matrix summarizes the mass flux of tritium with and without the background concentrations of tritium.
0.
Total Mass F'ux~
ý ' I Background' Total Mass Flux>
With Contribution
~<Without
Background
(Ci/yr),
Background (Ci/yr)
Tritium 65.68 0.12 65.46 Based on these results and current conditions at the Station, CRA concludes that the cumulative tritium mass flux from groundwater is 32.34 Ci/yr and 33.12 Ci/yr to the Intake and Discharge Canal, respectively.
Tritium Concentration in pCi/L The table below presents the flow-weighted average tritium concentrations in pCi/L in groundwater that discharges to surface water bodies (minus background).
~Description TAritium Concentration Flow weighted average tritium concentration - Intake 84,321 Canal (minus. background)
Flow weighted average tritium concentration - Discharge 41,462 Canal (minus background)
Flow weighted average tritium concentration - Total 125,783 (minus background) 055875 (2) Oyster Creek Generating Station 24 CONESTOGA-ROVERS & ASSOCIATES
5.0 REFERENCES
AMO Environmental Decisions, 2006 through 2009. Routine Groundwater and Surface Water Monitoring Rounds.
Conestoga-Rovers & Associates, May 2006. "Hydrogeologic Investigation Work Plan-Oyster Creek Generating Station".
Conestoga-Rovers & Associates, September 2006. "Hydrogeologic Investigation Report-Oyster Creek Generating Station".
Freeze, R.A. and J.A. Cherry, 1979. "Groundwater', Prentice-Hall, Inc., Englewood Cliffs, NJ.
http://www.deq.state.mi.us/documents/deq-dwrpd-gws-wpu-Tritium.pdf.
http://www.epa.gov/radiation/radionuclides/tritium.htm.
http://www.nrc. gov/NRR/OVERSIGHT/ASSESS/actionmatrixsummary.html.
Jersey Central Power & Light, Co. (JCP&L), Intake and Turbine Area Excavation &
Backfill Plans & Section, Drawing 4006-2.
New Jersey Pollutant Discharge Elimination System (NJPDES) Permit (Permit No. NJ0005550).
NJDEP, 2005, Field Sampling Procedures Manual, August 2005 Oyster Creek Site Characterization Plan.
Oyster Creek Generating Station Radiological Environmental Monitoring Program (REMP) Reports.
Puls and Barcelona, 1996. EPA/540/S-95/504.
U.S. Nuclear Regulatory Commission (NRC), 2007. Generic Environmental Impact Statement for License Renewal of Nuclear Plants, Supplement 28, Regarding Oyster Creek Nuclear Generating Station, Final Report - Main Report, NUREG-1437, Supplement 28, Washington, D.C, January 2007.
URS Greiner Woodward Clyde, 1999, Preliminary Assessment Report -
Non Radiological (Appendix M), December 20, 1999.
URS Greiner Woodward Clyde, February 28, 2000. Remedial Action Work Plan - Non Radiological.
URS Greiner Woodward Clyde, January 31, 2000.
Site Investigation/ Remedial Investigation - Non Radiological.
URS, February 11, 2005. Remedial Investigation - Response to October 13, 2004, NJDEP Comments Letter.
USGS Quadrangle Map (71/2 min), Oyster Creek Mosaic, New Jersey.
055875 (2) Oyster Creek Generating Station 25 CONESTOGA-ROVERS & ASSOCIATES
Woodward-Clyde Consultants, August 1983.
Phase I
- Report, Recommended Groundwater Monitoring System.
Woodward-Clyde Consultants, January 1992. Summary of Injection and Pumping Activities.
Woodward-Clyde Consultants, March 1984. Phase II Report, Groundwater Monitoring System.
055875 (2) Oyster Creek Generating Station 26 CONESTOGA-ROVERS & ASSOCIATES
TABLES
TABLE 1
SUMMARY
OF EXISTING MONITORING WELL INFORMATION MASS FLUX REPORT OYSTER CREEK GENERATING STATION FORKED RIVER, NEW JERSEY Hydrogeologic Sample Installation Surface Reference Boring Screened Interval Well Unit Location Date Northing Easting Elevation Elevation Total Depth Top Bottom Top Bottom Construction Screened (UTM Coordinates ) (NAVD 88) fv(NAVD 88) (ftbgs) 0)
(ft bgs)
(NAVD 88)
Page of 3 CST Monitoring Network MW-50 4/21/2009 357368.20 574436.80 13.25 13.71 MW-51 4/22/2009 357378.30 574480.80 25.12 25.60 MW-52 4/23/2009 357400.90 574353.00 13.08 13.58 MW-53 4/24y2009 357272.80 574447.60 14.88 15.25 MW-54 4Y24/2009 357276.20 574311.70 9.43 9.82 20 20 20 20 20 Radiological Monitoring Network W-1 W-2 W-3 W4 W-5 W-6 W-7 W-9 W-10 W-12 W-13 W-14 W-15 W-16 12/8/1983 357030.00 574140.51 21.26 20.93 11/8/1983 356965.07 574555.56 21.79 21.27 11/15/1983 357173.00 574499.10 19.18 18.95 11/11/1983 357176.21 574497.52 19.03 18.66 11/10/1983 357510.81 574373.89 22.29 21.80 11/9/1983 357513.77 574373.37 22.30 22.18 11/16/1983 Not Surveyed 11/1/1983 357289.45 574892.97 21.90 21.25 11/1/1983 357286.42 574890.70 21.90 21.73 12/7/1983 357665.89 574755.45 23.14 22.81 12/6/1983 357668.72 574755.21 22.81 22.67 11/3/1983 357702.60 575018.64 22.01 21.79 11/3/1983 357705.99 575017.61 21.94 21.77 11/4/1983 357967.48 574932.88 22.69 21.62 Diesel Fuel Monitoring/Dewatering Wells 50.0 57.0 24.0 55.0 20.5 52.0 20.0 20.0 60.0 20.0 50.0 53.0 20.0 20.0 20.0 20.0 20.0 20.0 39.0 20.0 19.0 20.0 20.0 20.0 19.5 19.5 19.5 19.5 19.5 19.5 40.0 10.0 20.0 3.25
-6.75 PVC-2" Cape May 10.0 20.0 15.12 5.12 PVC-2" Cape May 10.0 20.0 3.08
-6.92 PVC -2" Cape May 5.0 20.0 9.88
-5.12 PVC -2" Cape May 5.0 20.0 4.43
-10.57 PVC -2" Cape May 40.0 50.0
-18.74
-28.74 PVC (4)
Cohansey 45.0 55.0
-23.21
-33.21 PVC Cohansey 14.0 24.0 5.18
-4.82 PVC Cape May 42.0 52.0
-22.97
-32.97 PVC Cohansey 10.5 20.5 11.79 1.79 PVC Cape May 42.5 52.5
-20.20
-30.20 PVC Cohansey 10.0 20.0 PVC Cape May 10.0 20.0 11.90 1.90 PVC Cape May 47.0 57.0
-25.10
-35.10 PVC Cohansey 10.0 20.0 13.14 3.14 PVC Cape May 40.0 50.0
-17.19
-27.19 PVC Cohansey 43.0 53.0
-20.99
-30.99 PVC Cohansey 10.0 20.0 11.94 1.94 PVC Cape May 10.0 20.0 12.69 2.69 PVC Cape May PVC Cape May PVC Cape May 10.0 20.0 11.59 1.59 PVC Cape May PVC Cape May PVC Cape May PVC Cape May 8.5 18.5 13.26 3.26 PVC Cape May 9.5 19.5 12.28 2.28 PVC Cape May 10.0 20.0 12.01 2.01 PVC Cape May 10.0 20.0 12.03 2.03 PVC Cape May PVC Cape May PVC Cape May PVC Cape May PV C Cape M ay PVC Cape May PVC Cape May 30.0 40.0
-8.18
-18.18 PVC Cape May W-18 W-19 W-20 W-21 W-22 W-23 W-24 W-25 W-26 W-27 W-28 W-29 W-30 W-31 W-32 W-33 W-34 1/5/1988 357005.94 574621.53 22.09 21.79 1/4/1988 357078.09 574633.20 21.94 21.65 12/21/1987 356927.67 574542.41 21.81 21.59 12/22/1987 357009.35 574518.32 22.22 22.08 1/7/1988 357024.77 574590.11 22.14 21.74 1/6/1988 357055.18 574564.85 21.86 21.65 12/2/1988 357129.14 574650.80 21.76 21.23 12/5/1988 356962.80 574677.56 21.78 21.16 12/5/1988 357006.86 574643.90 22.01 21.63 12/6/1988 357042.65 574636.24 22.03 21.49 7/24/1989 356991.49 574573.60 21.90 21.64 7/25/1989 357012.98 574568.51 21.88 21.63 7/25/1989 357058.25 574516.64 22.58 22.24 7/25/1989 357052.05 574495.61 23.05 22.74 7/26/1989 356978.79 574528.41 22.10 21.86 7/25/1989 357027.30 574498.92 22.75 22.54 11/7/1991 357196.27 574649.37 21.82 21.53 055875 (2)-Th1-1 C0toga-55e7 & M-.-t
TABLE 1
SUMMARY
OF EXISTING MONITORING WELL INFORMATION MASS FLUX REPORT OYSTER CREEK GENERATING STATION FORKED RIVER, NEW JERSEY Hydrogeologic Sample Installation Surface Reference Boring Screened Interval Well Unit Location Date Northing Easting Elevation Elevation Total Depth Top Bottom Top Bottom Construction Screened (UTM Coordinates ' ) (NAVD 88) 2)(NAVD 88) (ft bgs) 0)
(ft bgs)
(NAVD 88)
Supplemental Network Page 2 of 3 W-1A 11/22/1993 358312.23 574678.80 22.14 W-1B 11/22/1993 358313.27 574685.47 22.26 W-2A 11/24/1993 358105.47 574348.03 19.42 W-2B 11/24/1993 358110.86 574348.28 19.72 W-3A 11/23/1993 358067.86 575664.61 20.58 W-3B 11/24/1993 358070.21 575656.06 20.58 W-4A 11/24/1993 356913.16 575386.94 20.36 W-4B 11/24/1993 356916.37 575388.51 16.78 Diversion Well Network W-1C W-1K W-2C W-2K W-3C W-3K W-4C W-4K W-5C W-5K 1977 357149.27 572740.94 27.57 1979 357152.49 572727.89 27.19 1977 357923.61 573809.58 22.79 1979 358031.09 573762.78 20.61 1977 356595.27 576663.23 6.62 1977 356602.30 576675.15 6.44
- 1977, 359305.15 575867.72 7.06 1977 359321.51 575874.25 7.42 1977 356758.17 580641.91 3.81 1979 356743.46 580646.07 3.93 21.87 22.04 19.12 19.47 19.76 19.59 19.87 16.50 27.97 26.04 24.27 20.51 8.67 9.04 10.05 10.24 4.64 4.67 24.25 23.66 23.31 22.29 25.31 13.43 12.79 13.09 21.84 50.0 20.0 50.0 20.0 50.0 20.0 50.0 20.0 60.0 150.0 60.0 150.0 60.0 100.0 60.0 100.0 60.0 150.0 24.0 20.0 45.0 19.0 17.5 19.0 18.0 17.0 25.0 40.0 10.0 40.0 10.0 40.0 10.0 40.0 10.0 50.0
-18.13 20.0 12.04 50.0
-20.88 20.0 9.47 50.0
-20.24 20.0 9.59 50.0
-20.13 20.0 6.5
-28.13 2.04 30.88
-0.53
-30.34
-0.41
-30.13
-3.5 PVC Cohansey PVC Cape May PVC Cohansey PVC Cape May PVC Cohansey PVC Cape May PVC Cohansey PVC Cape May PVC Cohansey PVC Kirkwood PVC Cohansey PVC Kirkwood PVC Cohansey PVC Kirkwood PVC Cohansey PVC Kirkwood PVC Cohansey PVC Kirkwood Industrial Site Recovery Act Wells MW-1A-2A 12/10/1999 357381.01 575043.41 23.00 MW-1G-1A 12/1/1999 358551.56 575308.98 21.99 MW-1G-1B Unknown 358550.95 575316.31 21.83 MW-1I-1A 12/10/1999 357598.45 574412.75 22.85 MW-1I-2A 12/3/1999 357579.73 574495.37 25.80 MW-15K-1, 12/10/1999 357297.91 574469.23 13.78 MW-24-2A 12/1/1999 356838.25 579471.24 10.09 MW-24-3A 12/1/1999 356828.45 578969.43 10.86 MW-16D 8/6/2004 357573.05 574746.19 22.33 14.2 8.0 9.0 7.5 9.0 8.0 7.0 15.0 24.2 8.80 18.0 13.99 19.0 13.85 17.5 18.30 19.0 4.43 18.0 2.09 17.0 3.86 25.0 6.84
-1.20 PVC Cape May 3.99 PVC Cape May Unknown Cape May 3.85 PVC Cape May 8.30 PVC Cape May
-5.57 PVC Cape May
-7.91 PVC Cape May
-6.14 PVC Cape May
-3.16 PVC Cape May 0585M (2)-Tbi-1 Con-tog.-Rme- & M-ocscs
TABLE 1
SUMMARY
OF EXISTING MONITORING WELL INFORMATION MASS FLUX REPORT OYSTER CREEK GENERATING STATION FORKED RIVER, NEW JERSEY Hydrogeologic Sample Installation Surface Reference Boring Screened Interval Well Unit Location Date Northing Easting Elevation Elevation Total Depth Top Bottom Top Bottom Construction Screened (UTM Coordinates ') (NA VD 88) 'V(NA VD 88) (ft bgs) '"
(ft bgs)
(NAVD 88)
Test Wells for 1977 Study of Hypothetical Radionuclide Spill Page3of3 LW-1 7/6/1977 LW-2 7/7/1977 LW-3 7/7/1977 LW-4 7/7/1977 357632.62 357645.52 357630.10 357652.25 575570.02 575581.72 575575.34 575573.74 20.39 20.75 20.32 21.34 20.37 20.67 20.41 21.03 21.0 21.0 21.0 49.0 300.0 145.0 PVC Cape May PVC Cape May 11.0 21.0 10.3 0.3 PVC Cape May 39.0 49.0
-17.97
-27.97 PVC Cohansey Carboh Kirkwood Black Steel K irkw ood Domestic/Make-up Water Wells South Well 11/1964 North Well 11/11/1987 Not Surveyed Not Surveyed Notes:
(1)
Universal Transverse Mercator (UTM), Zone 18, NAD 83, in feet (2)
NAVD 88 - North American Vertical Datum, 1988, in feet (3) ft bgs - feet below ground surface (4)
PVC - polyvinyl chloride Data not available (155875 (2}-1T*1-1
~5573t2).hi.1Co-1.g.-R.
oýi.-
TABLE 2
SUMMARY
OF GROUNDWATER ELEVATION DATA MASS FLUX REPORT OYSTER CREEK GENERATING STATION FORKED ROVER, NEW JERSEY Page 1 of 2 Formation Sample Location Cape May W-1B W-2B W-3B W-4B W-3 W-5 W-7 W-9 W-12 W-15 W-16 W-20 MW-15K-1A MW-1A-2A MW-1I-1A MW-1I-2A MW-16D MW-24-2A MW-24-3A LW-3 W-18 W-19 W-21 W-22 W-23 W-24
.7 W-25 W-26 W-27 W-28 W-29 W-30 W-31 W-32 W-33 LW-2 MW-1G-IA LW-1 W-50 W-51 W-52 W-53 W-54 Reference Elevation (NAVD 88) (1) 22.04 19.47 19.59 16.50 18.95 21.80 unable to survey 21.25 22.81 21.77 21.62 21.59 13.43 24.25 22.29 25.31 21.84 12.79 13.09 20.67 21.79 21.65 22.08 21.74 21.65 21.23 21.16 21.63 21.49 21.64 21.63 22.24 22.74 21.86 22.54 21.34 23.66 20.75 13.25 25.12 13.08 14.55 9.43 April 28, 2009 Total Depth to Groundwater Depth Water Elevation (ft below Reference) (ft below Reference)
(NA VD 88) 20.6 21.1 17.10 20.3 22.80 20.7 20.4 19.5 19.5 20.0 19.0 19.7 18.5 24.5 17.3 16.8 24.6 11.1 20.4 21.7 19.4 19.3 19.7 39.0 17.3 18.0 18.6 19.4 18.0 19.0 19.4 18.8 19.6 19.5 19.6 21.5 20.4 8.0 20.0 20.0 20.0 20.0 20.0 NA 5.73 6.31 7.31 15.66 12.37 13.63 15.27 14.80 11.51 9.50 16.24 5.87 15.36 11.81 12.14 17.72 10.00 10.58 6.96 14.22 14.11 16.07 19.59 13.66 13.39 13.86 13.80 18.85 19.33 16.18 17.04 15.66 16.68 7.55 9.79 7.05 8.98 13.75 10.74 8.82 7.22 NA 13.74 13.28 9.19 3.29 9.43 5.98 8.01 10.26 12.12 5.35 7.56 8.89 10.48 13.17 4.12 2.79 2.51 13.71 7.57 7.54 6.01 2.15 7.57 7.77 7.77 7.69 2.79 2.30 6.06 5.70 6.20 5.86 13.79 13.87 13.7 4.27 11.37 2.34 5.73 2.21 Access not provided 055875 (2)-Tbl-2 Conestoga-Rovers & Associates
TABLE 2
SUMMARY
OF GROUNDWATER ELEVATION DATA MASS FLUX REPORT OYSTER CREEK GENERATING STATION FORKED ROVER, NEW JERSEY Page 2 of 2 Formation Sample Location Cohansey Kirkwood W-1 W-1A W-2A W-4A W-2 W-3A W4 W-6 W-10 W-13 W-14 LW-4 W-34 MW-1G-1B W-1C W-2C W-3C W4C W-SC Reference Elevation (NA VD 88) (1) 20.93 21.87 19.12 19.87 21.27 19.76 18.66 22.18 21.73 22.67 21.79 21.03 21.53 23.31 27.97 24.27 8.67 10.05 4.64 Total Depth (ft below Reference) 49.0 50.0 51.0 50.2 53.6 44.8 48.5 47.7 55.0 48.9 52.0 48.3 39.5 45.1 48.2 46.7 60 60 39.0 150.0 150.0 100.0 100.0 150.0 April 28, 2009 Depth to Groundwater Water Elevation (ft below Reference)
(NA VD 88) 18.98 NA 18.24 12.74 19.61 17.67 16.88 20.60 17.88 19.68 18.32 17.93 17.93 21.3 18.04 22.49 5.53 9.10 0.60 9.80 7.31 2.70 5.67 2.20 1.95 NA 0.88 7.13 1.66 2.09 1.78 1.58 3.85 2.99 3.47 3.10 3.6 2.01 9.93 1.78 3.14 0.95 4.04 Access not provided W-1K W-2K W-3K W-4K W-5K 26.04 20.51 9.04 10.24 4.67 16.24 13.20 6.34 4.57 2.47 Notes:
(1)
NAVD 88 - North American Vertical Datum, 1988, in feet G55875 (2)-T-bl-2 Conestoga-Rovers & Associates
TABLE 3
SUMMARY
OF SURFACE WATER ELEVATION DATA MASS FLUX REPORT OYSTER CREEK GENERATING STATION FORKED RIVER, NEW JERSEY Page 1 of 1 Sample Location Reference Elevation (ft AMSL) (1)
April 24, 2006 Depth to Water Surface Water (ft Below Elevation Reference)
(ft AMSL)
SW-1 (2)
SW-2 (3)
North Bridge (4)
South Bridge
-1.10 1.85 11.10 11.10 1.40 1.15 12.78 10.60
-2.50 (estimated) 0.70
-1.68 0.50 Note:
(1)
(2)
(3)
(4) ft AMSL - feet above mean sea level Surveyed, by others to NGVD 1929, converted to NGVD 1983 Installed, surveyed, and measured on April 28, 2009 Only surface water gauging performed 055875 (2)-Tbl-3 Conestoga-Rovers & Associates
TABLE 4
SUMMARY
OF CALCULATED VERTICAL HYDRAULIC GRADIENTS AT WELL CLUSTER LOCATIONS MASS FLUX REPORT OYSTER CREEK GENERATING STATION FORKED RIVER, NEW JERSEY Page 1 of I Sample Location W-3 W-4 W-5 W-6 W-9 W-10 W-12 W-13 W-15 W-14 Formation CM CO CM CO CM CO CM CO CM CO Top of Screen Elevation (NA VD 88) t 5.18
-22.97 11.97
-20.20 11.90
-25.10 13.14
-17.19 11.94
-20.99 Bottom of Screen Elevation (NAVD 88)
-4.82
-32.97 1.79
-30.20 1.90
-35.10 3.14
-27.19 1.94
-30.99 Mid-Point of Screen Elevation (NAVD 88) 5.00
-27.97 6.88
-25.20 6.90
-30.10 8.14
-22.19 6.94
-25.99 Water Level (NA VD 88 3.01 1.86 7.94 1.83 5.47 3.91 7.45 3.17 9.06 3.45 April 24, 2006 -
Vertical Gradient
- 8)
(ft/ft downward) (2) 0.035 0.190 0.042 0.141 0.170 Water Level (NAVD 88 3.29 1.78 9.43 1.58 5.98 3.85 8.01 2.99 10.26 3.47 April 28, 2009 Vertical Gradient
)
(ft/ft downward) (2) 0.046 0.245 0.058 0.166 0.206 Notes:
(1)
(2)
CM CO NAVD 88 - North American Vertical Datum, 1988, in feet Positive value denotes downward vertical gradient; negative value denotes upward vertical gradient Cape May Formation Cohansey Formation 055875 (2)-Thl-Conestoga-Rovers & Associates
TABLE 5
SUMMARY
OF AQUIFER TESTING DATA MASS FLUX REPORT OYSTER CREEK GENERATING STATION FORKED RIVER, NEW JERSEY Page 1 of I Well Identification Formation W-1 Cohansey W-2 Cohansey W-3 Cape May W-4 Cohansey W-5 Cape May W-6 Cohansey W-7 Cape May W-8 Fill W-9 Cape May W-10 Cohansey W-12 Cape May W-13 Cohansey W-14 Cohansey W-15 Cape May W-16 Cape May W-17 Kirkwood AVG All Permeability (ft/sec) 3.00E-04 2.80E-04 2.20E-04 3.70E-04 2.60E-04 1.40E-04 2.10E-04 1.30E-03 3.30E-06 3.30E-05 1.10E-04 4.50E-04 3.50E-04 3.30E-04 2.80E-04 1.50E-04 2.99E-04 Permeability (ft/day) 25.92 24.19 19.01 31.97 22.46 12.10 18.14 112.32 0.29 2.85 9.50 38.88 30.24 28.51 24.19 12.96 25.85 AVG Cape May AVG Cohansey AVG Kirkwood 2.02E-04 2.75E-04 1.50E-04 17.44 23.74 12.96 Notes:
- 1) ft/sec = feet per second.
- 2) Data source for W-1 through W-17: Phase II Report, Groundwater Monitoring System (Woodward Clyde Consultants, March 1984)
- 3) Data source for W-18 through W-33: (Preliminary Assessment Report - Non Radiological (Appendix M), URS Greiner Woodward Clyde, December 20, 1999) 055875 (1)-Tbl-5 Conestoga-Rovers & Associates
TABLE 6
SUMMARY
OF TRITIUM DATA MASS FLUX REPORT OYSTER CREEK GENERATING STATION FORKED RIVER, NEW JERSEY Page 1 of 4 W-5 Teledyne Brown OC MW-15K-1A Teledyne Brown OC MW-50 Teledyne Brown MW-51 Teledyne Brown Date of Sample OC 3/12/2009 4/15/2008 4/16/2008 4/17/2008 4/18/2008 4/19/2008 4/20/2008 4/21/2008 4/22/2008 4/23/2008 4/24/2008 4/25/2008 4/26/2008 4/27/2008 4/29/2008 5/1/2009
<200
<200
<200 2 480 000 4,890,000
<200 2,390,000U 5.050,000 4,890,000 6,050,000 3,600_000 Notes:
- 1) All results in picoCuries per liter (pCi/L)
- 2) OC = Sample analyzed by Oyster Creek
- 3) Teledyne Brown = Sample analyzed by Teledyne Brown 055875 (2)-Tbl-6 Conetoga-Rovers & Associates
TABLE 6
SUMMARY
OF TRITIUM DATA MASS FLUX REPORT OYSTER CREEK GENERATING STATION FORKED RIVER, NEW JERSEY Page 2 of 4 MW-52 I
Teledyne Brown 00 MW-53 Teledyne Brown 00 MW-54 Teledyne Brown 00 CST -9 Teledyne Brown Date of Sample OC 3/12/2009 4/15/2008 4/16/2008 4/17/2008 4/18/2008 4/19/2008 4/20/2008 4/21/2008 i
4/22/2008 4/23/2008 4/24/2008
<2,000 4/25/2008 27 4/26/2008 4/27/2008
- -2 4/29/2008 5/1/2009 9,000 7 950
<LLD j
<200
<200 Notes:
- 1) All results in
- 2) OC = Samplk
- 3) Teledyne Brc 055875 (2)-Thl-6 Conega-Rovem & Assodates
TABLE 6
SUMMARY
OF TRITIUM DATA MASS FLUX REPORT OYSTER CREEK GENERATING STATION FORKED RIVER, NEW JERSEY Page 3 of 4 Date of Sample OC 3/12/2009 4/15/2008 4/16/2008 4/17/2008 4/18/2008 4/19/2008 4/20/2008 4/21/2008 4/22/2008 4/23/2008 4/24/2008 4/25/2008 4/26/2008 4/27/2008 4/29/2008 5/1/2009 W-3 Teledyne Brown W-4 W-6 I eledyne Brown OC Teledyne Brown OC
<200
<200
<200
<200
<2ý00
<200
<200 Notes:
- 1) All results in
- 2) OC = Samplk
- 3) Teledyne Br(
055875 (2)-Trbl-6 Conestoga-Rovers & Associates
TABLE 6
SUMMARY
OF TRITIUM DATA MASS FLUX REPORT OYSTER CREEK GENERATING STATION FORKED RIVER, NEW JERSEY Page 4 of 4 MW-II-1A Teledyne Brown MW-1 1-2A Teledyne Brown CST-2 Teledyne Brown Date of Sample OC 3/12/2009 4/15/2008 4/16/2008 4/17/2008 4/18/2008 4/19/2008 4/20/2008 4/21/2008 4/22/2008 4/23/2008 4/24/2008 4/25/2008 4/26/2008 4/27/2008 4/29/2008 5/1/2009 OC OC
<200
<200
<200 i
~Dry Dry
<200 Notes:
1 )All results in
- 2) OC = Samph
- 3) Teledyne Br(
055875 (2)-Tbl-6 Conestoga-Rovers & Associates
TABLE 7 MASS FLUX CALCULATIONS MASS FLUX REPORT OYSTER CREEK GENERATING STATION FORKED RIVER, NEW JERSEY Page I of 3-ID Input Tritium Concentration (pCiL) 179 17!
17!
179 17!
17!
179 27!
27!
Area (sq ft)
Hydraulic Hydraulic Conductivity Gradient (ft/lft)
(ft/day)
GmnwtrWeighted Ave.
Rootangle Mass Subtotal Mass Ionptentrtionu G-ondsst-nrgl-s C.-otstotio olut-(F/ux (pCial)
(pCvyr)
Flu (CI/yo)
(pCVL) MINUS BACKGROUND Weighted Ane.
Subtotal Mass onetaon Rectangle Subtotal BFlux (Ci/Vy) -
(pCi/gal) MINUS Bux (pCi/kr)
MusMyr)
Without BACKGROUNDackground ZM-I-9 20 0519 5.191 1%
2,M44,189,5131 ZM-1-15 1--
000,0,0j 50(
201 ol
~bwtuti031 0.03 0.2)
ZO-I-08-A 1751 5,0001 25 0
3.9oI 0.931 1,357A4,05861 0
c 1,357,454,0861 1.14-B I
25 0.023 3.72 0.901 1-300,83,4991 1
1 o-I O
I 0-1,300,893,499 ISubltul' 32.10 rOTAL-INTAKE CANAl
-hubtoal 22,324 11.41 22,278 0.W 32-L 055875 (2)-*,t-7 A 5-.fO ov-A -i
TABLE7 MASS FLUX CALCULATIONS MASS FLUX REPORT OYSTER CREEK GENERATING STATION FORKED RIVER, NEW JERSEY Page 2of 3 r
r r
r I
I I
r ID DISCHARGE CANAL Zape May Foewation
-M-D-01 ZM.D-02 ZM-D-03
-M-DD-4
-M-D-05 ZM-D-06
- M-D-07 253-0-08
-M-DmO9
-M-D-10 ZM-D-t1
-,-*-D-12 2M-D-13 Zohny Formation 2OD--01-A 2O-[m02-A ZO-D-03-A O-D045-A 2O-D-04-B O-D0-05-A ZO-DmOS-B O-D0-06-A O-D0-6-B O-D-07-A ZO-m007-B 0-D0-08-A O-D-00-B O-D-09-A 2O-0-09-B O-D-10-A 20-D-18-B O-D-11-A 2OD-I-B D-12-A ZO-D-12-B Input Tntium Conentti Area (sq )
(pCV/U Hydraulic Conductivity (ft/dry)
Hydraulic Gradient (ff/f0)
T*dafi Chtpcl Avp Groundwater I ncen1...
Flor(gal/win) Co__tr' Rectangle Mnss Fluu (pCi/yr)
Input Tritum SubtotalM Concetation Fu (Cvyr)
(pC/L) MINUS BACKGROUND Weiglhted Are.
Cnonenlxafoo (pCVgal) MINUS BACKGROUND Background Man Flou (pc0/r)
Subtotal Satbtotal Maos M Fl (Cvyo) -
Mass Fl Without (Ci/yr)
Background
1*J 2(
0.01 723,975,512 904,969,391 5,1712.53660 51,712.536,605 1,034,250,732,093 0,342,507-320,930 D,695,014,641,859 Subtotal*
1,000,000 2,500 251 0.015 1751 125 251 487 4.87 4.87 4.87 4.87 4.07 1.62 1.62 1.62 1.62 1.62 1.62 1.62
~I0(
I 565,605,869 25 0.01 0.o01 1.621 569.591 6464067*07.558
.s.ig.i.II I.1.0 FOTAL-DISCHARGE CANAL Subtlotal 1511 29,2261 10,9541 1_______ 0.051 33.12 65.58 I
I I
I wool 0)-MI'
TABLE7 MASS FLUX CALCULATIONS MASS FLUX REPORT OYSTER CREEK GENERATING STATION FORKED RIVER, NEW JERSEY Page 3 of 3 GROUNDWATER FLOW IN THE CAPE MAY FORMATION TO THE INTAKE CANAL 90Rgpm I
o GROUNDWATER FLOW IN THE COHANSEY FORMATION TO THE INTAKE CANAL 102 Rp,
I GROUNDWATER FLOW TO THE INTAKE CANAL T
193 gp GROUNDWATER FLOW IN THE CAPE MAY FORMATION TO TH E DISCHARGECANAL 40R*
gI I
GROUNDWATER FLOW IN THE COHANSEY FORMATION TO THE DISCHARGE CANAL 110 fTp GROUNDWATER FLOW TO THE DISCHARGE CANAL
_ _____lSgpI Rpm TOTAL GROUNDWATER FLOWOFFSTATION 343Rpm FLOWWEIGHTED AVETRITIUM CONCENTRATION - INTAKE CANAL 84;496p 1 C.-L o
84.321 pCi/L -
FLOW WEIGHTED AVE TRITIUM CONCENTRATION -DISCHARGE CANAL 10I ll ', 2 p0I/L 41,462 pCi/L FLOW WEIGHTED AVETRITIUM CONCENTRATION OFF STATION 195,116 i/L
.1 25,783 pCi/L I
I
_i__
__I_
1751 pCi/ L = msumed background
-nmnttion
-_[
5Mximum tn concenixtration wa aumed o be 2,ISS(SX pCi/L L.[
SSime them am data gaps at the disxhoege points, theme i great uncertainty in this sumption.
I _
Cen.... oes*I
_____I I
I ___________
14401rn in a day I
I I _
_I 7.481gallow in a cubic foot I
[ I 285321liters i a cubic foot I
1._
_E-12lp sit yi.
I I
I IWE-IZ2 itoCt
_____1_____2_____
_____I______
-net ut-ni-,
APPENDIX A WELL LOGS
WELL CONSTRUCTION LOG Project Name:
Project No.:
Client:
Location:
Survey Information:
Top of inner casing:
Ground surface; Oyster Creek 55875 Exelon Forked River, NJ Well Designation Date Completed:
Drilling Method:
CRA Scientist:
Driller:
Northing:
Easting:
W-50 412112009 Hollow Stem Auger Martin Mylet B.L. Myers Feet MSL 13.25 Feet MSL 357368.2 574436.8 NOT TO SCALE Protective Casing Height:
N/A Existing Surface Concrete Casing:
Diameter:
N/A Material: NIA Depth:
N/A Grout:
Composition: Portland Type I cement with 5% bentonite Flush Mount 4--
Boring:
Diameter:
HSA Nominal 4.5-inch Riser:
Diameter:
Length:
Connections:
Material:
2-inch 10 Flush-threaded PVC Bentonite Seal Material: Chips, hydrated Screen:
Slot Size: 20 slot 1 0.01-inch Length:
10 feet Diameter.
2-inch Material:
PVC 1.5 Feet BGS, Top of Seal 8
Feet BGS, Top of #2 Sand 10 Feet BGS, Top of Screen SandlGravel Size:
- 2 Material:
Silica Sand Bottom Plug Material:
PVC Connection:
Threaded Groundwater:
First Encountered:
Static Level:
ApproxI 2.0 9.20 (24April09) 20 Feet BGS, Bottom of Screen 20 Feet BGS, Depth of Boring Depths Below Ground Surface (BGS)
Development was completed by surge and pump technique.
CRA
WELL CONSTRUCTION LOG Project Name:
Oyster Creek Project No.:
65875 Client:
Exelon Location:
Forked River, NJ Survey Information:
Top of Inner casing:
Feet MSL Ground surface:
22.5 Feet MSL Well Designation:
Date Completed:
Drilling Method:
CRA Scientist:
Driller:
Northing:
Easting:
W-51 4/2212009 Hollow Stem Auger Martin Mylet B.L Myers 357378.3 574480.8 NOT TO SCALE 6-inch Casing Protective Casing Height:
3.0' Existing Surface Existing Surface...
Concrete Casing:
Diameter:
N/A Material: N/A Depth:
NIA Grout:
Composition: Portland Type I cement with 5% bentonite
.k Boring:
Diameter:
Riser:
Diameter:
Length:
Connections:
Material:
HSA Nominal 4.5-inch 2-inch 13 Flush-threaded PVC Bentonite Seal Material: Chips, hydrated Screen:
Slot Size: 20 slot / 0.01-inch
.Length:
10 feet Diameter:
2-inch Material:
PVC SandlGravel Size:
- 2 Material: Silica Sand Bottom Plug Material:
PVC Connection:
Threaded 1.5 Feet BGS, Top of Seal 8
Feet BGS, Top of #2 Sand 10 Feet BGS, Top of Screen Groundwater:
First Encountered: Approx 12.5' Top of Casing Static Level:
20 Feet BGS, Bottom of Screen 20 Feet BGS, Depth of Boring Depths Below Ground Surface (BGS)
Development was completed by surge and pump technique.
CRA
WELL CONSTRUCTION LOG Project Name:
Oyster Creek Project No.:
55875 Client:
Exelon Location:
Forked River, NJ Survey Information:
Top of inner casing:
Feet MSL Ground surface:
13.58 Feet MSL Well Designation:
Date Completed:
Drilling Method:
CRA Scientist:
Driller:
Northing:
Easting:
W.52 412312009 Hollow Stem Auger Martin Mylet B.L. Myers 357400.9 574353 NOT TO SCALE Flush Mount Protective Casing Height:
NIA Existing Surface Concrete Casing:
Diameter:
NIA Material: N/A Depth:
NIA Grout:
Composition; Portland Type I cement with 5% bentonite Boring:
Diameter HSA Nominal 4.5-inch Riser:
Diameter.
Length:
Connections:
Material:
2-inch 10 Flush-threaded PVC Bentonite Seal Material: Chips, hydrated Screen:
Slot Size: 20 slot / 0.01-inch Length:
10 feet Diameter:
2-inch Material:
PVC SandlGravel Size:
- 2 Material: Silica Sand Bottom Plug Material:
PVC Connection:
Threaded 1.5 Feet BGS, Top of Seal 8
Feet BGS, Top of #2 Sand 10 Feet BGS, Top of Screen Groundwater:
First Encountered:
Static Level:
Approx 11.0 10.4 (24April09) 20 Feet BGS, Bottom of Screen 20 Feet BGS, Depth of Boring Depths Below Ground Surface (BGS)
Development was completed by surge and pump technique.
CRA
WELL CONSTRUCTION LOG Project Name:
Oyster Creek Project No.:
55875 Client:
Exelon Location:
Forked River, NJ Survey Information:
Top of inner casing:
Feet MSL Ground surface:
15.25 Feet MSL Well Designation:
Date Completed:
Drilling Method:
CRA Scientist:
Driller:
Northing:
Easting:
W-53 4/24/2009 Hollow Stem Auger Martin Mylet B.L. Myers 357272.8 574447.6 NOT TO SCALE Protec Existing Surface Flush Mount 4--
tive Casing Height:
N/A Concrete Boring:
Diameter:
Casing:
Diameter:
N/A Material: N/A Depth:
N/A Riser:
Diameter:
Length:
Connections:
Material:
HSA Nominal 4.5-inch 2-inch 5
Flush-threaded PVC Grout:
Composition: Portland Type I cement with 5% bentonite 1.5 Feet BGS, Top of Seal Bentonite Seal Material: Chips, hydrated Screen:
Slot Size: 20 slot t 0.01-inch Length:
15 Diameter:
2-inch Material:
PVC Sand/Gravel Size:
- 2 Material:
Silica Sand Bottom Plug Material:
PVC Connection:
Threaded 3
Feet BGS, Top of #2 Sand 5
Feet BGS, Top of Screen Groundwater:
First Encountered:
Static Level:
Approx 11.0 20 Feet BGS, Bottom of Screen 20 Feet BGS, Depth of Boring Depths Below Ground Surface (BGS)
Development was completed by surge and pump technique.
CRA
WELL CONSTRUCTION LOG Project Name:
Oyster Creek Project No.:
65875 Client:
Exelon Location:
Forked River, NJ Survey Information:
Top of inner casing:
Feet MSL Ground surface:
9.82 Feet MSL Well Designation:
Date Completed:
Drilling Method:
CRA Scientist:
Driller:
Northing:
Easting:
W-54 4/24/2009 Hollow Stem Auger Martin Mylet B.L. Myers 357276.2 574311.7 NOT TO SCALE Protect Existing Surface Flush Mount 4-*
tive Casing Height:
N/A Concrete Casing:
Diameter:
N/A Material: N/A Depth:
N/A Boring:
Diameter:
Riser:
Diameter:
Length:
Connections:
Material:
HSA Nominal 4.5-inch 2-inch 5
Flush-threaded PVC Grout:
Composition: Portland Type I cement with 5% bentonite Bentonite Seal Material: Chips, hydrated Screen:
Slot Size: 20 slot 10.01-inch Length:
15 Diameter:
2-inch Material:
PVC SandlGravel Size:
- 2 Material: Silica Sand Bottom Plug Material:
PVC Connection:
Threaded 1.5 Feet BGS, Top of Seal 3
Feet BGS, Top of #2 Sand 5
Feet BGS, Top of Screen Groundwater:
First Encountered:
A Static Level:
pprox 13.0 20 Feet BGS, Bottom of Screen 20 Feet BGS, Depth of Boring Depths Below Ground Surface (BGS)
Development was completed by surge and pump technique.
CRA