Text

Indian Point 2, 3rd Interval Inservice Inspection Plan APPENDIX A ISI PROGRAM P&IDS XCN008.0601 Revision 0 A-1 9402280411 940208 PDR ADOCK 05000247 a

PDR

I.,.

Indian Point 2, 3rd Interval Inservice Inspection Plan APPENDIX A TABLE OF CONTENTS ISI PROGRAM P&IDS SYSTEM ISI Classification Coding Legends Flow Diagram Symbols Auxiliary Coolant System Auxiliary Coolant Systems Auxiliary Coolant System Steam Generator Blowdown & Blowdown Sample System Boiler Feedwater System Chemical & Volume Control System Chemical & Volume Control System Chemical & Volume Control System Chemical & Volume Control System Hydrogen Recombiner System Condensate & Boiler Feed Pump Suction Main Steam System Main Steam Traps Process Radiation Monitoring Process Radiation Monitoring Reactor Level Instrumentation Reactor Coolant System Safety Injection System Safety Injection System Sampling System Service Water System Nuclear Steam Supply Plant, Sh. 1 of 2 Service Water System Nuclear Steam Supply Plant, Sh. 2 of 2 Waste Disposal System XCN008.0601 Revision 0 DRAWING NO.

9321 -C-2016-09 A227781-45 A251783-02 9321 -F-2720-61 9321 -F-2729-48 9321-F-2019-77 A235309-16 9321 -F-2736-69 9321 -F-2737-45 A208168-29 9321 -F-2727-30 9321-F-2018-93 9321-F-2017-61 9321 -F-2041-24 B235122-02 C235117-02 A208798-13 9321 -F-2738-72 A235296-22 9321 -F-2735-1 00 9321 -F-2745-39 9321 -F-2722-75 A209762-32 9321 -F-2730-52 A-2

Indian Point 2, 3rd Interval Inservice Inspection Plan APPENDIX A ISl CLASSIFICATION CODING LEGEND Red NOTES:

1)

LI Blue NOTES:

QUALITY GROUP AISI CLASS I Quality Group A (ISI Class 1) components subject to all examinations per IWB-1200 and IWF-1200.

Quality Group A components are those within the A Boundary Flags on the ISI P&IDs.

Quality Group A components which are exempt from examination per IWB 1220 are _nt color coded on the ISI P&IDs.

QUALITY GROUP B/lSI CLASS 2 Quality Group B (ISI Class 2) components subject to all examinations per IWC-1200 and IWF-1200.

Quality Group B components are those within the B Boundary Flags on the ISI P&IDs.

Quality Group B components which are exempt from examination per IWC 1220 are not color coded on the ISI P&IDs.

QUALITY GROUP C/ISI CLASS 3

=

Quality Group C (S[ Class 3) components subject to all examinations per IWD-1200 and IWF-1200.

Green NOTES: 1)

Quality Group C components are those within the C Boundary Flags on the ISI P&IDs.

2)

Quality Group C components which are exempt from examination per IWD 1220 are not color coded on the ISI P&IDs.

XCN008.0601 Revision 0