Revision to License Amendment Request 09-007, Model D5 Steam Generator Alternate Repair Criteria
ML092670205
Person / Time
Site: Comanche Peak  
Issue date: 09/17/2009
From: Flores R
Luminant Generation Co, Luminant Power
To:
Document Control Desk, Office of Nuclear Reactor Regulation
References
CP-200901341, TAC ME1446, TAC ME1447, TXX-09117
Download: ML092670205 (3)


Text

Rafael Flores Senior Vice President

& Chief Nuclear Officer rafael.flores@Luminant.com Luminant Power P 0 Box 1002 6322 North FM 56 Glen Rose, TX 76043 Lum inant 2548975550 C 817 559 0403 F 254 897 6652 CP-200901341 Ref. #

10 CFR 50.90 Log # TXX-09117 September 17, 2009 U. S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, DC 20555

SUBJECT:

COMANCHE PEAK STEAM ELECTRIC STATION (CPSES)

DOCKET NOS. 50-445 AND 50-446 REVISION TO LICENSE AMENDMENT REQUEST 09-007, MODEL D5 STEAM GENERATOR ALTERNATE REPAIR CRITERIA (TAC NOS. ME1446 AND ME1447)

REFERENCES:

1. Letter logged TXX-09075 dated June 8, 2009, from Rafael Flores of Luminant Power to the NRC submitting License Amendment Request (LAR)09-007.
2.

Letter dated July 23, 2009, from Balwant Singal of NRR to Rafael Flores.

3.

Letter dated August 11, 2009, from Balwant Singal of NRR to Rafael Flores

4.

Letter logged TXX-09096 dated August 20, 2009, from Rafael Flores of Luminant Power to the NRC submitting Response to Request for Additional Information Regarding License Amendment Request (LAR)09-007.

5.

Letter logged TXX-09105 dated August 27, 2009, from Rafael Flores of Luminant Power to the NRC submitting Response to Request for Additional Information Regarding License Amendment Request (LAR)09-007.

6.

Letter logged TXX-09113 dated September 14, 2009, from Rafael Flores of Luminant Power to the NRC submitting a Revision to License Amendment Request (LAR)09-007.

Dear Sir or Madam:

Per Reference 1, Luminant Generation Company LLC (Luminant Power) requested an amendment to the Comanche Peak Steam Electric Station, herein referred to as Comanche Peak Nuclear Power Plant (CPNPP), Unit 1 Operating License (NPF-87) and Unit 2 Operating License (NPF-89) by revising the CPNPP Unit 1 and 2 Technical Specifications (TSs).

The proposed change revises TS 5.5.9.2, Unit 1 Model D76 and Unit 2 Model D5 Steam Generator (SG)

Program, to exclude portions of the Unit 2 Model D5 steam generator tube below the top of the SG tubesheet from periodic steam generator tube inspections.

The NRC provided Luminant Power with requests for additional information (RAI) via References 2 and

3. References 4 and 5 provided the responses to the RAIs. Reference 6 provided a revision to Reference 1 to be a one-time change to TS 5.5.9.2 and TS 5.6.9 for Unit 2 during Refueling Outage 11 and the subsequent inspection cycle.

A member of the STARS (Strategic Teaming and Resource Sharing) Alliance Callaway

  • Comanche Peak
  • Diablo Canyon
  • Palo Verde
  • San Onofre
  • Wolf Creek

U. S. Nuclear Regulatory Commission TXX-09117 Page 2 09/17/2009 On September 15, 2009, in an email between NRC Staff and Luminant Power, NRC Staff indicated the commitment for the condition monitoring assessment needed to be revised.

This communication contains the following revised licensing basis commitment which will be completed or incorporated into the Comanche Peak licensing basis as noted:

Number Commitment Due Date/Event 3779679 For the condition monitoring (CM) assessment, the During each inspection of the component of operational leakage from the prior cycle Unit 2 steam generators required from below the H* distance will be multiplied by a by TS 5.5.9.2 starting in Refueling factor of 3.16 and added to the total accident leakage Outage 2RF12.

from any other source and compared to the allowable accident induced leakage limit. For the operational assessment (OA), the difference in the leakage between the allowed accident induced leakage and the accident induced leakage from sources other than the tubesheet expansion region will be divided by 3.16 and compared to the observed operational leakage. An administrative limit will be established to not exceed the calculated value.

Luminant Power requests approval of the proposed license amendment by September 30, 2009, to support the Comanche Peak Unit 2 Fall 2009 (2RF11) refueling outage. The proposed license amendment will be implemented within 30 days of the issuance of the license amendment.

In accordance with 10 CFR 50.91(b), Luminant Power is providing the State of Texas with a copy of the proposed license amendment.

Should you have any questions, please contact Mr. Jack Hicks at (254)897-6725.

I state under penalty of perjury that the foregoing is true and correct. Executed on the 17th day of September, 2009.

Sincerely, Luminant Generation Company LLC Rafael Flores Bv:

Aa W-J Fred W. Madden Director, Oversight & Regulatory Affairs

U. S. Nuclear Regulatory Commission TXX-09117 Page 3 09/17/2009 c -

E. E. Collins, Region IV B. K. Singal, NRR Resident Inspectors, Comanche Peak Alice Hamilton Rogers, P.E.

Inspection Unit Manager Texas Department of State Health Services Mail Code 1986 P. 0. Box 149347 Austin, TX 78714-9347