ADAMS Accession Nos.:

Package: ML91980265 E-Mail: ML091980256 Attachment (Draft RAIs): ML091980266 From:

Beltz, Terry Sent:

Friday, July 17, 2009 11:20 AM To:

'mkscarpello@aep.com' Cc:

'pgschoepf@aep.com'; 'jazwolinski@aep.com'; 'jmpetro@aep.com'; Huang, Tai

Subject:

Donald C. Cook Nuclear Plant, Unit 2 (CNP-2) - Draft RAIs re: LBLOCA Amendment Request (ME1017)

Attachments:

Donald C. Cook Nuclear Plant, Unit 2 - LBLOCA LAR - Draft RAIs.doc

Dear Mr. Scarpello:

This e-mail is in reference to Indian Michigan Power Company's (I&M, the licensee) license amendment request dated March 19, 2009 (Agencywide Documents and Access Management System (ADAMS) Accession No. ML090930453). The proposed amendment would adopt a new analysis of a large break loss-of-coolant accident (LBLOCA) for CNP-2. The new analysis is performed using the NRC-approved methodology set forth in Westinghouse Topical Report WCAP-16009-P-A, Realistic Large-Break LOCA Evaluation Methodology Using the Automated Statistical Treatment of Uncertainty Method (ASTRUM). I&M proposes to endorse this methodology by a revision to Technical Specification (TS) 5.6.5, "Core Operating Limits Report (COLR)."

I&M also requests NRC approval to revise TS 3.4.1, "RCS [Reactor Coolant System] Pressure, Temperature, and Flow Departure from Nucleate Boiling (DNB) Limits," to change the minimum RCS total flow rate from 366,400 to 354,000 gallons per minute (gpm). I&M states that the current value is a minimum measured flow value includes allowances for flow uncertainty, and that current practice is that the thermal design flow value, which does not include allowances for flow measurement uncertainty, be specified in TSs. The minimum measured flow is specified in the COLR. That value is currently 354,000 gpm and is also reflected in the new LBLOCA analyses.

Finally, I&M proposes to amend TS 3.5.2, ECCS - Operating. Condition D allows the unit to be in Mode 1, 2, or 3 for an unlimited amount of time if a Safety Injection (SI) system cross-tie valve is closed, provided that thermal power is reduced to less than or equal to a specified value. The new LBLOCA analysis being proposed does not address a condition in which an SI cross-tie valve is closed. Therefore, the allowance provided by Condition D will be deleted, as well as reference to Condition D in TS 3.5.2, Conditions A and C.

The NRC staff in the Reactor Systems Branch has reviewed I&M's submittal and developed draft requests for additional information (RAI). The draft RAIs are provided as an attachment to this e-mail. The NRC staff would like to discuss the draft RAIs with you in a conference call or meeting. Among other things, the discussion will include how the NRC would formally issue these questions and how the licensee will respond to them.

The sole purpose of this e-mail and its attachment is to prepare you and others for the proposed conference call or meeting. This e-mail and its attachment do not convey a formal NRC staff position, and do not formally request for additional information.

Please don't hesitate to contact me if you have any questions or concerns.

Sincerely, Terry A. Beltz, Senior Project Manager Plant Licensing Branch III-1 Division of Operating Reactor Licensing Office of Nuclear Reactor Regulation (301) 415-3049 Terry.Beltz@nrc.gov E-mail Properties Mail Envelope Properties (BB882299B277DB4C9C9A613B507A6F601DC6B26E90)

Subject:

Donald C. Cook Nuclear Plant, Unit 2 (CNP-2) - Draft RAIs re: LBLOCA Amendment Request (ME1017)

Sent Date: 7/16/2009 8:18:48 AM Received Date: 7/17/2009 11:20:00 AM From: Beltz, Terry Created By: Terry.Beltz@nrc.gov Recipients:

mkscarpello@aep.com ('mkscarpello@aep.com')

Tracking Status: None pgschoepf@aep.com ('pgschoepf@aep.com')

Tracking Status: None jazwolinski@aep.com ('jazwolinski@aep.com')

Tracking Status: None jmpetro@aep.com ('jmpetro@aep.com')

Tracking Status: None Tai.Huang@nrc.gov (Huang, Tai)

Tracking Status: None Post Office:

HQCLSTR01.nrc.gov Files Size Date & Time MESSAGE 70620 7/16/2009 DC Cook, Unit 2 - LBLOCA LAR - Draft RAIs.doc 58058

Options Expiration Date:

Priority: olImportanceNormal ReplyRequested: False Return Notification: False Sensitivity: olNormal Recipients received: