Rancho Seco Final Status Survey Summary Report September 30, 2008 20' Auxiliary Steam Support Survey Unit F8132132 Prepared By:
Date:
FSS Engineer Reviewed By:
4 j."
Date:
10?A O-Lead FSS Engineer Approved By:
' z
/
Date:
7-Dismantlement Sie~rintendent, Radiological
FINAL STATUS SURVEY
SUMMARY
REPORT Survey Unit:
F8132132, 20' Auxiliary Steam Support Survey Unit
Description:
Operating History: The reinforced concrete structure contained the RadWaste processing and supporting systems. The building contained six main elevations. Residual radioactive material was known to be present on all levels of the interior of the building.
Operating records and the HSA document several events with the potential for a release of radioactivity inside this structure. One report documented contamination of the auxiliary building roof. The roof was later replaced.
Site Characterization: Direct measurements were made of each of the interior elevation surfaces as well as the exterior surfaces of the structure. These measurements confirmed the presence of plant-derived radionuclides. Direct measurements on the -47' elevation showed a mean gross activity level of 320,071 dpm/100 cm2 and a maximum value of 5,720,000 dpm/100 cm 2. Direct measurements on the -29' elevation showed a mean gross activity level of 544,756 dpm/100 cm 2 and a maximum value of 11,370,000 dpm/1 00 cm2. Direct measurements on the -20' elevation showed a mean gross activity level of 247,831 dpm/100 cm2 and a maximum value of 10,080,000 dpm/100 cm 2. Direct measurements on the grade elevation showed a mean gross activity level of 373,758 dpm/100 cm 2 and a maximum value of 5,800,000 dpm/100 cm 2. Direct measurements on the +20' elevation showed a mean gross activity level of 85,408 dpm/100 cm 2 and a maximum value of 1,900,000 dpm/100 cm 2. Direct measurements on the +40' elevation showed a mean gross activity level of 3,288 dpm/100 cm 2 and a maximum value of 24,781 dpm/100 cm 2.
Direct measurements on the building exterior, including the mezzanine roof, showed a mean gross activity level of 1 897 dpm/100 cm 2 and a maximum value of 2,990 dpm/l100 cm 2. (The roof had been replaced prior to the classification survey.) Based on the classification procedure (DSIP-0020) and levels of gross activity reported, the interior of the auxiliary building was determined to be a Class 1, 2 area and the exterior was a Class 2,3.
HSA Events: HSA Report pg. 63.
Survey Unit Design Information:
The Survey Unit Design Parameters are presented in Table I below. The survey unit and measurement locations are depicted on the maps in Attachment 1. Direct measurement locations were determined using a random-start, fixed grid pattern and 105 m2 were scanned for approximately 38% coverage. Samples of removable contamination were collected at each direct measurement location. The instrumentation used for the survey along with the MDC values are listed in Tables 2-1 and 2-2 in Attachment 2.
Page 2 of 8 FSS Summary Report F8132132
Table 1. Survey Unit Design Parameters
.Survey Design Value Comment Parameter Survey Area:
F813 Survey Unit:
Class:
SU Area (m2):
Evaluator:
DCGL (dpm/100 cm'):
Area Factor:
Design DCGLemc (dpm/100 cm2):
LBGR (dpm/100 cm2):
Design Sigma (dpm/100 cm 2):
Type I Error:
Type II Error:
Predominant Nuclide:
Sample Area (m2):
Scan Area (M2):
Scan Coverage (%):
ZI-* :
ZI-P* :
Sign P:
Calculated Relative Shift:
Relative Shift Used:
N-Value:
Design N-Value + 20%:
Design Min Samples N:
Grid Spacing L:
2132 2
276.5 Gary Frank 43000 N/A N/A 21500 342 0.05 0.05 Cs-137 19.75 105 38%
1.645 1.645 0.99865 62.8 3
11 14 14 4.4 20' Auxiliary Steam Support Structure Surface LTP Table 5-4 Gross Activity DCGL Class 2 Class 2 Default = 50% DCGL DTBD-06-001, Table 5-4D Class 2 Class 2 Uses 3.0 if Relative Shift is
>3 NUREG-1575 Table 5-5 Class 2 Class 2 Page 3 of 8 FSS Summary Report F8132132
Survey Results:
A total of 14 direct measurements were made in F8132132. The results including mean, median, standard deviation and range are shown in Table 2. All direct measurements were less than the DCGL. None of the scan measurements indicated areas of elevated activity. Scan activity ranged from 2188 to 26064 dpm/l 00 cm 2, based on a surveyor efficiency of 0.5 and no background subtracted. Samples for removable surface activity were all less than 10% of the DCGL as shown in Table 3. Removable surface activity samples were counted for alpha activity and none was detected at the MDC shown in Table 2-1 of Attachment 2.
Table 2. Direct Measurement Results Measurement ID Gross Activity (dpm/1O0 cm F8132132-COOOIBD 8678 F8132132-CO002BD 2345 F8132132-CO003BD 1847 F8132132-CO004BD 1909 F8132132-CO005BD 1784 F8132132-CO006BD 1966 F8132132-CO007BD 2023 F8132132-CO008BD
.1613 F8132132-CO009BD 1790 F8132132-COOlOBD 1753 F8132132-COOI1 BD
.1639 F8132132-CO012BD 1987 F8132132-CO013BD 1105 F8132132-CO014BD 1608 Mean:
2289 Median:
1818 Standard Deviation:
1860 Range:
1105-8678 Page 4 of 8 FSS Summary Report F8132132
Table 3. Removable Surface Activity Results Measurement ID Surface Beta Activity (dpm/1:00 cm2)
F8132132C0001SM F8132132C0002SM F8132132C0003SM F8132132C0004SM F8132132C0005SM F8132132C0006SM F8132132C0007SM F8132132C0008SM F8132132C0009SM F8132132C0010SM F8132132C0011SM F8132132C0012SM F8132132C0013SM F8132132C0014SM Mean:
Median:
Standard Deviation:
Range:
25.54 1
2.29 1
-1.58 2.29
-0.29
-1.58
-0.29
-1.58 2.29
-0.29
-0.29 1
2.11 0.35 6.89
-1.58 to 25.54 Page 5 of 8 FSS Summary Report F8132132
Survey Unit Data Assessment:
The survey design required 14 direct measurements for the Sign Test. The critical value and the results of the Sign Test are presented in Table 4. The sample mean and median values were less than the DCGL. The sample standard deviation was greater than the design standard deviation. Since both values of sigma resulted in a relative shift greater than three (3), no additional samples were required.
Page 6 of 8 FSS Summary Report F8132132
Table 4. Data Assessment Results Survey Results Parameter Value Comment Material Background Used (dpm/100 cm2):
N/A Ambient Background Used (dpm/100 cm2):
N/A Average Ambient BKG = 0 Actual Direct Measurements (N):
14 Median (dpm/100 cm2):
1818 Mean (dpm/100 Cm2):
2289 Direct Measurement Standard Deviation 1860 (dpm/100 cm 2):
Total Standard Deviation (dpm/100 cm 2):
1860 Based on samples and backgrounds.
Maximum (dpm/100 cm 2):
8678 Material Type:
N/A Background Subtract Not Applied Sign Test Final N Value:
14 S+ Value:
14 Critical Value:
10 Sufficient Samples Collected:
Yes.
Maximum Value < DCGL:
Yes Median Value < DCGL:
Yes Mean Value < DCGL:
Yes Maximum Value < DCGLemc:
N/A Class 2 Total Standard Deviation <= Sigma:
Investigate
<DCGLw Pass the Sign Test?
Yes Reject the Null Hypothesis?
Yes Does the Survey Unit Pass All Criteria?
Investigate Survey Unit Passes Page 7 of 8 FSS Summary Report F8132132
Survey Unit Investigations and Results:
No investigations were required for either direct or scan measurements and no investigation results are reported. Elevated area was discovered in the area of beta scans 71 and 74, the area was remediated and resurveyed under F8132134.
ALARA Statement:
As stated in Chapter 4 of the LTP, as long as the residual activity within the survey unit is less than the DCGL, the ALARA criterion has been met.
Changes in Initial Survey Unit Assumptions:
The survey unit was designed as a Class 2 structure survey and the sample results are consistent with that classification. The variability of the survey results was greater than the characterization data used for survey design. However, no additional samples were required. One potential area of elevated activity was detected the area was reclassified as a Class I remediated and resurveyed under F8132134.
==
Conclusion:==
The FSS of this survey unit was properly designed as a Class 2 survey based on Table 5-4 of the LTP. The required number of direct measurements was made and the scan coverage met the requirement of Table 5-6 of the LTP. No direct measurements exceeded the DCGL of 43000 dpm/100 cm2 and none of the removable surface activity measurements exceeded 10% of the DCGL. No investigations were required.
The direct measurement data support rejection of the null hypothesis, providing high confidence that the survey unit satisfied the release criteria and that the data quality objectives were met.
It is concluded that survey unit F8132132 meets the release criteria of 10CFR20.1402.
Page 8 of 8 FSS Summary Report F8132132
Attachment I Maps September 30, 2008 Survey Unit F8132132
(D Auxiliary Building Exterior 20' Auxiliary Steam Support Beta Scans Delete 1 - 4 Juncture Scans
- 4.Pr--7" 2(Y
--l I 0tý RO. 1 t~
115 1 7
.1I M 05 1JS 02 24 25 12,1 22 2
03 10 0
20 02 16 17 18 01 07 1.Z_
l_
14 15 40 4
3 39 34 37 38 IN
'Looking South 189 ft" 17 6 M2 North Face 69 ft2 6.4 mr 2
I43 I 44 1 4
4 24'!,,
i i
- 4j ReflectedCi ln 7
489 fei 45.4 ml r-1 72 1 73 1 74 76 69 170 71 1175
'66 67 0618'V 24' 04 65 61 62 20' Elev 33-11~
5-9 60 16 526 ft' 7.
48.9 ml
-10'-.5-Delete 82, 87 and 88 wail drawn Incorrectly Deflector Wall 261 fir 24.2 m2 Looking Soulhwest 707 ftI 65.7 ml 10 UDIIlectIo vail 20'-0" ELEV. Crotch Walls Screen
>'/ -\\
!l 2
19o}
06 00 2
0 Looking West 66m' Deleted 94 and 105 mistake in measurement It 00 U'
uJ 1',.
F8132132-Ml
(D 0q Auxiliary Building Exterior 20' Auxiliary Steam Support Beta Direct 90-85 80 75 70-65-60 77-0m 55 50 45 Li 40 35 Deflector Wall 30 25 20 -
15 10--
41-r-4 1I.90 09 Looking South 189 ft2 17.6 m2 North Face 69 ft 6.4 mzr 2
-34'-S 34..5-2._________
lAM 0:722m, 1.4m 25'"
5.'"'
N4 2 0.66m S\\
/
1134 2'A!e.
Deflector Wall 261 t 20 Elev 24.2 m.
/
Reflected Ceiling 526 ft' 489 ftm 03 48.9 m2 45.4M2 v10.5.-1 20'-0" ELEV. Crotch Walls Looking West 66mf 00 Lw
..... I.... I.... I.... I.... I.... I.... I.... I.... I.... I.... I.... I.... I.... I.... I.... I.... I.... I.... I.... I.... I.... I.... I.... I.... I.... I..... I.... I.... I.... I.... I.... I.... I.... I 5
10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 95 100 105 110 115 120 125 130 135 140 145 150 155 160 165 170 F8132132-M2
0 cj~
90 -
85 -
80 -
75-70-65 -
60-55 -
50-45 -
40 -
35-7 30 -
25 -
20 -
15--
10 -
5-Auxiliary. Building Exterior 20' Auxiliary Steam Support Gamma Scan GS#9 GO#10 GD#2 GD#9 3D#7 GD#3 GD#7 N
GD#6 GD#4 GD#1 GS#57 /Floor GS#4 GS#1 GS#2 GS#3 5
10 15 20 25 30 35 40 45 50 55 60 *65 70 75 80
- 85 90 95 100 105 110 115 120 125 130 135 140 145 150 155 160 165 170 F81 321 32-M3
ýI1 00
K Page 5 of 6 Att. 1 Maps F8132132
C\\
0ON ff
-Z-Ril i
/*
lii 1
/,
U~iii lioi
\\
1 I 01, r-...
7][-T EELIF i
ih,."
l
"!~ii ii
°-:-::..
Location of 20' Auxillary Steam Support inside the Industrial Area (A
4:*
i\\
i i......
"Map F..32132-M4, Auxiliary Building 20Auxiliary Steam (A-.0 iSupport t
o I
Instrumentation September 30, 2008 Survey Unit F8132132
Table 2-1. Survey Unit Instrumentation Instrument Detector MDC Static MDC Scan Model; Serial No.
Model; Serial No.
(dpm/100 cm 2 )
(dpm/100 cm 2 )
5.2 pCi/g M2350; 193700 44-10; 256101 N/A Ci-g Cs-137 M2350; 175834 43-68B; 148634 433 1033 M2350; 193715 43-68B; 148630 433 1033 M2350; 193715 43-116-1B; 256007 491 739 Tennelec; 0401171 N/A 5 dpm a, 11 dpm 3 N/A Table 2-2. Investigation Criteria and DCGL Value Parameter Vmluc (dpm/100 cm2)
Investigation Criteria - Direct 43000 Investigation Criteria - Scan 43000 DCGLw 43000 DCGLEMC N/A Page 2 of 2 Att. 2 Instrumentation F8132132 Investigation September 30, 2008 Survey Unit F8132132 (none required)
Data Assessment September 30, 2008 Survey Unit F8132132
DF8132132 Gross Activity Sample Results Quantile Plot o
DCGL = 43000 dpm/1 00cm2 10,000 -
9,0 0 0 -",
8,000 -*
7,000 6,000 U
5,000 4,0 0 0.-
1 8 1 1,000 -
0 20 40 60 80 100 Percentile
- 0 Direct Measurements (dpm/100cm2)
-median 75th Percentile -
50th Percentile
0 2o, F8132132 Gross Activity Sample Results Scatter Plot DCGL = 43000 dpmlO00cm3 1 0 0 0 0........
0 E
6000-A f
4000
~E 02000
-0 o-
-- o" 22 Zh 0
(n r.Cn~
1 0
-4000 C
C C 0 0
0 C
0 0
0 C
in in in in in in in in in in in in in r
0 0
3 a
C0 00 0
0 r
N 0
V o
a a
a a
a a
a D.
a a
a a
a o
0 0
0 0
0 0
0 0
0 0
0 0
0 U
U U
U U
U U
U U
U U
U U
U Measurement Locations 00
ý3e o
Gross Actity -
Average -
"+3StDev"-
"-3StDev
('3.
N),,
0 F81 32132 Gross Activity Frequency Plot DCGL = 43000 dpm/1 00cm2 1
1 1
1
.2 3
2 1
0 9
8 7
6 5
4 3
2 0
co It 00 Bins - Upper End Value (dpm/lOOcm2)