Rancho Seco Final Status Survey Summary Report November 17, 2008 Fuel Pool Piping system Survey Unit F8990441 Prepared By: *Z1.

cDate:

0/1-7/z2)OQ FSS Engineer Reviewed By:

Date:... I k

(-1I4 Lead FSS Engineer Approved By: Ž"1-7 Date:

7-'

Dismantlement uperintendent, Radiollogical

FINAL STATUS SURVEY

SUMMARY

REPORT Survey Unit:

F8990441, Fuel Pool Piping system Survey Unit

Description:

Operating History: This system transported radioactive fuel pool water through the coolers and clean up demineralizers. This system was designed to be contaminated.

Operating records and the HSA support its status as radioactively contaminated system piping.

Site Characterization: Direct measurements were made of the interior surfaces of the system piping which confirmed the presence of plant-derived radionuclides. Direct measurements of the interior showed a mean gross activity level of 5,190,000 dpm/100 cm 2 and a maximum value of 16,500,000 dpm/100 cm2. Based on the classification procedure (DSIP-0020) and levels of gross activity reported, the system was determined to be a Class 1 system.

HSA Events: N/A Radioactive by design.

Survey Unit Design Information:

The Survey Unit Design Parameters are presented in Table I below. The survey unit and measurement locations are depicted on the maps in Attachment 1. Direct measurement locations were spaced at 15cm intervals and 38 m2 were scanned for 100% coverage. The instrumentation used for the survey along with the MDC values are listed in Tables 2-1 and 2-2 in Attachment 2.

Page 2 of 29 FSS Summary Report F8990441

Table 1. Survey Unit Design Parameters Survey Design Value Comment Parameter Survey Area:

Survey Unit:

Class:

SU Area (m2):

Evaluator:

DCGL (dpm/lO0 em2):

Area Factor:

Design DCGLemc (dpm/100 cm 2):

LBGR (dpm/100 cm 2):

Design Sigma (dprn/100 cm2):

Type I Error:

Type II Error:

Predominant Nuclide:

Sample Area (m2):

Scan Area (m2):

Scan Coverage (%):

Sign P:

Calculated Relative Shift:

Relative Shift Used:

N-Value:

Design N-Value + 20%:

Design Min Samples N:

Grid Spacing L:

F899 0441 1

38 Erin L. Brown 100000 1

100000 50000 100000 0.05 0.05 Cs-137 N/A 38 100%

1.645 1.645 0.691462 0.5 0.5 74 89 89 0.6 Fuel Pool Piping system Embedded Pipe LTP Table 5-4 Gross Activity DCGL Class 1 Class 1 Default 50% DCGL Embedded Pipe

,Class 1 Lses 3.0 if Relative Shift is

>3 NUREG-1575 Table 5-5 Class I Class 1 Page 3 of 29 FSS Summary Report F8990441

Survey Results:

A total of 1243 direct measurements were made in F899044 1. The results including mean, median, standard deviation and range are shown in Table 2. All direct measurements were less than the DCGL. None of the measurements indicated areas of elevated activity. Measured activity ranged from 1260 to 26111 dpm/ 100 cm2, based on the pipe detector efficiency.

Table 2. Direct Measurement Results Measurement ID Gross! Activit (dpmli00 cm F8990441-MOO01GI 4020 F8990441-MOO02GI 3678 F8990441-MOO03GI 3967 F8990441-MOO04GI 4230 F8990441-MOO05GI 4519 F8990441-MOO06GI 4293 F8990441 -MOO07GI 4745 F8990441-MOO08GI 4561 F8990441-MOO09GI 4614 F8990441-MOOOGI 4745 F8990441 -MO011 GI 5003 F8990441 -MOO12GI 4587 F8990441-MOO13GI 4330 F8990441-MOO14GI 5060 F8990441 -MOO15GI 5176 F8990441-MOO16GI 4861 F8990441-M0025GI 2486 F8990441-M0026GI 2553 F8990441-M0027GI 2726 F8990441-M0028GI 2789 F8990441-M0029GI 2702 F8990441-MOO30GI 2789 F8990441-MOO31GI 2659 F8990441-M0032GI 2842 F8990441-M0033GI 2567 F8990441-M0034GI 2803 F8990441-M0035GI 2760 F8990441-M0036GI 2943 F8990441-M0037GI 2553 F8990441-M0038GI

.2534 F8990441-M0039GI 2543 F8990441-MOO40GI 2317 F8990441-MOO41GI 2481 F8990441-M0042GI 2461 F8990441-M0043GI 2587 F8990441-M0044GI 2784 F8990441-M0045GI 2601 F8990441-M0046GI 2601 F8990441-M0047GI 2553 F8990441-M0048GI1 2726 Page 4 of 29 FSS Summary Report F8990441

F8990441-M0049GI 2510 F8990441-MOO50GI 2418 F8990441-MOO51GI 2693 F8990441-M0052GI 2452 F8990441-M0053GI 2582 F8990441-M0054GI 2669 F8990441-M0055GI 2770 F8990441-M0056GI 2514 F8990441-M0057GI 2750 F8990441-M0058GI 2543 F8990441-M0059GI 2413 F8990441-MOO60GI 2654 F8990441-MOO61GI 2601 F8990441-M0062GI 2596 F8990441-M0063GI 2654 F8990441-M0064GI 2529 F8990441-M0065GI 2630 F8990441-M0066GI 2654 F8990441-M0067GI 2413 F8990441-M0068GI 2413 F8990441-M0069GI 2635 F8990441-MOO70GI 2596 F8990441-M0071GI 2524 F8990441-M0072GI 2596 F8990441-M0073GI 2539 F8990441-M0074GI 2799 F8990441-M0075GI 2842 F8990441-M0076GI 2722 F8990441-M0077GI 2697 F8990441-M0078GI 2664 F8990441-M0079GI 2755 F8990441-MOO80GI 2678 F8990441-M0081GI 2683 F8990441-M0082GI 2967 F8990441-M0083GI 2635 F8990441-M0084GI 2741 F8990441-M0085GI 2673 F8990441-M0086GI 2558 F8990441-M0087GI 2702 F8990441-M0088GI 2587 F8990441-M0089GI 2673 F8990441-MOO90GI 2630 F8990441-M0091GI 2582 F8990441-M0092GI 2803 F8990441-M0093GI 2563 F8990441-M0094GI 2697 F8990441-M0095GI 2625 F8990441-M0096GI 2890 F8990441-M0097GI 2683 F8990441-M0098GI 2823 F8990441-M0099GI 2808 F8990441-MO100GI 2707 F8990441-MO101GI 2702 F8990441-MO102GI 2731 F8990441-MO103GI 2746 F8990441-MO104GI 2866 Page 5 of 29 FSS Summary Report F8990441

F8990441-MO105GI 2861 F8990441-MO106GI 2592 F8990441-MO107GI 2664 F8990441-MO108GI 2775 F8990441-MO109GI 2837 F8990441-MO110GI 2490 F8990441-MO111GI 2818 F8990441-MO112GI 2596 F8990441-MO113GI 2852 F8990441-MO114GI 2688 F8990441-M0115GI 2510 F8990441-MO116GI 2746 F8990441-MO117GI 2659 F8990441 -MO 119GI 2688 F8990441-MO120GI 2755 F8990441-MO121GI 2861 F8990441-M0122GI 2832 F8990441-M0123GI 2847 F8990441-M0124GI 2635 F8990441-MO125GI 3131 F8990441-M0126GI 2909 F8990441-M0127GI 2876 F8990441-MO128GI 2861 F8990441-MO129GI 2616 F8990441-MO130GI 2881 F8990441-MO131GI 2611 F8990441-M0132GI 2529 F8990441-M0133GI 2755 F8990441-M0134GI 2837 F8990441-M0135GI 2673 F8990441-M0136GI 2861 F8990441-M0137GI 2755 F8990441-M0138GI 2669 F8990441-M0139GI 2567 F8990441-MO140GI 2842 F8990441-MO141GI 2842 F8990441-M0142GI 2770 F8990441-M0143GI 2770 F8990441-M0144GI 2592 F8990441-M0145GI 2779 F8990441-M0146GI 2890 F8990441-M0147GI 2659 F8990441-M0148GI 2934 F8990441-M0149GI 2885 F8990441-MO150GI 2765 F8990441-MO151GI 2741 F8990441-M0152GI 2620 F8990441-M0153GI 2755 F8990441-M0154GI 2938 F8990441-MO155GI 2582 F8990441-MO156GI 2914 F8990441-M0157GI 2866 F8990441-M0158GI 2447 F8990441-MO159GI 2654 F8990441-MO160GI 2885 F8990441-MO161GI 2741 Page 6 of 29 FSS Summary Report F8990441

F8990441-M0165GI 2428 F8990441-M0166GI 2736 F8990441-M0167GI 2722 F8990441-M0168GI 2625 F8990441-M0169GI 2726 F8990441-MO170GI 2823 F8990441-MO171GI 2803 F8990441-M0172GI 2828 F8990441-M0173GI 2803 F8990441-M0174GI 2765 F8990441-M0175GI 2750 F8990441-M0176GI 2683 F8990441-M0177GI 2808 F8990441-M0178GI 2861 F8990441-M0179GI 2967 F8990441-MO180GI 2890 F8990441-MO181GI 2784 F8990441-M0182GI 2789 F8990441-M0183GI 2760 F8990441-M0184GI 2779 F8990441.-M0185GI 2669 F8990441-M0186GI 2823 F8990441-MO187GI 2736 F8990441-M0188GI 2808 F8990441-M0189GI 2881 F8990441-MO190GI 2900 F8990441-MO191GI 2750 F8990441-MO192GI 2871 F8990441-M0193GI 2856 F8990441-M0194GI 2707 F8990441-M0195GI 2784 F8990441-M0196GI 2914 F8990441-M0197GI 2847 F8990441-M0198GI 2736 F8990441-M0199GI 2770 F8990441-MO200GI 3035 F8990441-MO201GI 2832 F8990441-M0202GI 2934 F8990441-M0206GI 4383 F8990441-M0207GI 3136 F8990441-M0208GI 2765 F8990441-M0209GI 2601 F8990441-MO210GI 2948 F8990441-MO211GI 3179 F8990441-M0212GI 3020 F8990441-M0213GI 2919 F8990441-M0214GI 2885 F8990441-M0215GI 2452 F8990441-M0216GI 2938 F8990441-M0217GI 3054 F8990441-M0218GI 2909 F8990441 -M0219GI 3150 F8990441-M0220GI 3203 F8990441 -M0221 GI 3121 F8990441-M0222GI 2890 F8990441-M0223GI 2770 Page 7 of 29 FSS Summary Report F8990441

F8990441-M0224GI F8990441-M0225GI F8990441-M0226GI F8990441-M0227GI F8990441-M0228GI F8990441-M0229GI F8990441-M0230GI F8990441-M0231GI F8990441-M0232GI F8990441-M0233GI F8990441-M0234GI F8990441-M0235GI F8990441-M0236GI F8990441-M0237GI F8990441-M0238GI F8990441-M0239GI F8990441-M0240GI F8990441-M0241GI F8990441-M0242GI F8990441-M0243GI F8990441-M0249GI F8990441-M0250GI F8990441-M0251GI F8990441-M0252GI F8990441-M0253GI F8990441-M0254GI F8990441-M0255GI F8990441-M0256GI F8990441-M0257GI F8990441-M0258GI F8990441-M0259GI F8990441-M0260GI F8990441-M0261GI F8990441-M0262GI F8990441-M0263GI F8990441-M0264GI F8990441-M0265GI F8990441-M0266GI F8990441-M0267GI F8990441-M0268GI F8990441-M0269GI F8990441-M0270GI F8990441-M0271GI F8990441-M0274GI F8990441-M0275GI F8990441-M0276GI F8990441-M0277GI F8990441-M0278GI F8990441-M0279GI F8990441-M0280GI F8990441 -M0281 GI F8990441-M0282GI F8990441-M0283GI F8990441-M0284GI F8990441-M0285GI F8990441-M0286GI 2669 2895 2924 2895 2958 2741 2967 3189 3044 2803 3102 3136 3642 2948 2876 2876 2958 2996 3357 3333 2789 2832 2746 3059 3179 2794 3001 2871 2967 2958 2900 2813 2775 2543 2823 2832 2856 2948 3039 2847 2760 2828 2760 3068 2856 3444 3126 2871 2803 2750 2919 2934 2794 2823 2808 3011 Page 8 of 29 FSS Summary Report F8990441

  • 1*

F8990441-M0287GI 2900 F8990441-M0288GI 2837 F8990441-M0289GI 2789 F8990441-M0290GI 2746 F8990441-M0291GI 2852 F8990441-M0292GI 2852 F8990441-M0293GI 2803 F8990441-M0294GI 2794 F8990441-M0295GI 3092 F8990441-M0296GI 2881 F8990441-M0297GI 2717 F8990441-M0298GI 2726 F8990441-M0299GI 2770 F8990441-MO300GI 2871 F8990441-MO301GI 2832 F8990441-M0302GI 3030 F8990441-M0303GI 2847 F8990441-M0304GI 2837 F8990441-M0305GI 2673 F8990441-M0306GI 2683 F8990441-M0307GI 2866 F8990441-M0308GI 2779 F8990441-M0309GI 2741 F8990441-M0310GI 2616 F8990441-M0311GI 2746 F8990441-M0312GI 2794 F8990441-M0313GI 2900 F8990441-M0314GI 2596 F8990441-M0315GI 2683 F8990441-M0316GI 2784 F8990441-M0317GI 2924 F8990441-M0318GI 2620 F8990441-M0319GI 2731 F8990441-M0320GI 3006 F8990441-M0321GI 2486 F8990441-M0322GI 2707 F8990441-M0323GI 2630 F8990441-M0324GI

.2852 F8990441-M0325GI 2837 F8990441-M0326GI 2524 F8990441-M0327GI 2327 F8990441-M0328GI 2625 F8990441-M0329GI 2803 F8990441-M0330GI 2669 F8990441-M0331GI 2664 F8990441-M0332GI 2750 F8990441-M0333GI 2616 F8990441-M0334GI 2905 F8990441-M0335GI 2587 F8990441-M0336GI 2514 F8990441-M0337GI 2452 F8990441-M0338GI 2770 F8990441-M0339GI 2587 F8990441-M0340GI 2563 F8990441-M0341GI 2563 F8990441-M0342GI 2625 Page 9 of 29 FSS Summary Report F8990441

F8990441 -M0343GI 2688 F8990441-M0344GI 2577 F8990441-M0345GI 2775 F8990441-M0346GI 2755 F8990441-M0347GI 2548 F8990441-M0348GI 2775 F8990441-M0349GI 2404 F8990441-M0350GI 2693 F8990441-M0351GI 2731 F8990441-M0352GI 2784 F8990441-M0353GI 2818 F8990441-M0354GI 2750 F8990441-M0355GI 2601 F8990441-M0356GI 2770 F8990441-M0357GI 2664 F8990441-M0358GI 2712 F8990441-M0359GI 2765 F8990441-M0360GI 2717 F8990441-M0361GI 2794 F8990441-M0362GI 2645 F8990441-M0363GI 2962 F8990441-M0364GI 2866 F8990441-M0365GI 2837 F8990441-M0366GI 2592 F8990441-M0367GI 2673 F8990441-M0368GI 2929 F8990441-M0371GI 1755 F8990441-M0372GI 1673 F8990441-M0373GI 1640 F8990441-M0374GI 1682 F8990441-M0375GI 1628 F8990441-M0376GI 1740 F8990441-M0377GI 1661 F8990441-M0378GI 1755 F8990441-M0379GI 1637 F8990441-M0380GI 1609 F8990441-M0381GI 1652 F8990441-M0382GI 1771 F8990441-M0383GI 1783 F8990441-M0384GI 1704 F8990441-M0385GI 1506 F8990441-M0386GI 1609 F8990441-M0387GI 1661 F8990441-M0388GI 1625 F8990441-M0389GI 1637 F8990441-M0390GI 1743 F8990441-M0391GI 1752 F8990441-M0392GI 1692 F8990441-M0393GI 1640 F8990441-M0394GI 1737 F8990441-M0395GI 1725 F8990441-M0396GI 1634 F8990441-M0397GI 1588 F8990441 -M0398GI 1606 F8990441-M0399GI 1606 F8990441-MO400GI 1618 Page 10 of 29 FSS Summary Report F8990441

F8990441-MO401GI 1585 F8990441-M0402GI 1701 F8990441-M0403GI 1908 F8990441-M0404GI 1944 F8990441-M0405GI 1923 F8990441 -M0406GI 1722 F8990441-M0407GI 1816 F8990441 -M0408GI 1564 F8990441-M0409GI 1771 F8990441-M0410GI 1886 F8990441-M0411GI 1740 F8990441-M0412GI 1807 F8990441-M0413GI 1801 F8990441-M0414GI 1761 F8990441-M0415GI 1819 F8990441-M0416GI 1722 F8990441-M0417GI 1655 F8990441-M0418GI 1789 F8990441-M0419GI 2044 F8990441-M0420GI 1740 F8990441-M0421GI 1856 F8990441-M0422GI 1822 F8990441-M0423GI 1965 F8990441-M0424GI 1771 F8990441-M0425GI 1758 F8990441-M0426GI 1783 F8990441-M0427GI 1612 F8990441-M0428GI 1685 F8990441-M0429GI 1725 F8990441-M0430GI 1752 F8990441-M0431GI 1752 F8990441-M0432GI 1789 F8990441-M0433GI 1932 F8990441-M0434GI 1841 F8990441-M0435GI 1892 F8990441-M0436GI 1935 F8990441-M0437GI 1704 F8990441-M0438GI 1926 F8990441-M0439GI 1877 F8990441-M0440GI 1838 F8990441-M0441GI 1911 F8990441-M0442GI 1959 F8990441-M0443GI 1783 F8990441-M0444GI 1898 F8990441-M0445GI 2011 F8990441-M0446GI 2057 F8990441-M0447GI 1990 F8990441-M0448GI 2069 F8990441-M0449GI 2017 F8990441-M0450GI 1987 F8990441-M0451GI 2029 F8990441-M0452GI 2026 F8990441-M0453GI 2190 F8990441-M0454GI 1984 F8990441-M0455GI 1880 F8990441-M0456GI 2440 Page I11 of 29 FSS Summary Report F8990441

F8990441-M0457GI 2738 F8990441-M0458GI 2583 F8990441-M0459GI 2622 F8990441-M0460GI 1389 F8990441-M0461GI 1325 F8990441-M0462GI 1752 F8990441-M0463GI 4145 F8990441-M0464GI 20128 F8990441-M0465GI 14380 F8990441-M0466GI 14957 F8990441-M0467GI 16261 F8990441-M0468GI 20043 F8990441-M0469GI

.20620 F8990441 -M0470GI 14081 F8990441-M0471GI 7778 F8990441-M0472GI 6218 F8990441-M0473GI 6239 F8990441-M0474GI 3910 F8990441-M0475GI 3632 F8990441-M0476GI 3355 F8990441-M0477GI 3226 F8990441-M0478GI 3333 F8990441-M0479GI 3568 F8990441-M0480GI 3269 F8990441-M0481GI 2671 F8990441-M0482GI 3504 F8990441-M0483GI 3440 F8990441-M0484GI 3248 F8990441-M0485GI 3953 F8990441-M0486GI 4744 F8990441-M0487GI 5791 F8990441-M0488GI 7564 F8990441-M0489GI 9893 F8990441-M0490GI 7735 F8990441-M0491GI 7521 F8990441-M0492GI 7799 F8990441-M0493GI 12799 F8990441-M0494GI 26111 F8990441-M0495GI 20128 F8990441-M0496GI 6731 F8990441-M0497GI 5833 F8990441-M0498GI 6368 F8990441-M0513GI 1658 F8990441-M0514GI 1533 F8990441-M0515GI 1646 F8990441-M0516GI 1749 F8990441-M0517GI 1838 F8990441-M0518*31 1777 F8990441-M0519GI 1600 F8990441-M0520GI 1634 F8990441-M0521GI 1746 F8990441-M0522GI 1743 F8990441-M0523GI 1606 F8990441-M0524GI 1661 F8990441-M0525GI 1685 F8990441-M0526GI1 1652 Page 12 of 29 FSS Summary Report F8990441

F8990441-M0527GI 1673

ýF8990441-M0528GI 1603 F8990441-M0529GI 1628 F8990441-M0530GI 1615 F8990441-M0531GI 1555 F8990441-M0532GI 1625 F8990441-M0533GI 1755 F8990441-M0534GI 1667 F8990441-M0535GI 1701 F8990441-M0536GI 1728 F8990441-M0537GI 1688 F8990441-M0538GI 1628 F8990441-M0539GI 1628 F8990441-M0540GI 1850 F8990441-M0541GI 1786 F8990441-M0542GI 1612 F8990441-M0543GI 1737 F8990441-M0544GI 1603 F8990441-M0545GI 1725 F8990441-M0546GI 1856 F8990441-M0547GI 1640 F8990441-M0548GI 1795 F8990441-M0549GI 1701 F8990441-M0550GI 1765 F8990441-M0551GI 1755 F8990441-M0552GI 1664 F8990441-M0553GI 1692 F8990441-M0554GI 1698 F8990441-M0555GI 1707 F8990441-M0556GI 1728 F8990441-M0557GI 1710 F8990441-M0558GI 1536 F8990441-M0559GI 1655 F8990441-M0560GI 1722 F8990441-M0561GI 1472 F8990441-M0562GI 1618 F8990441-M0563GI 1649 F8990441-M0564GI 1670 F8990441-M0565GI 1719 F8990441-M0566GI 1579 F8990441-M0567GI 1734 F8990441-M0568GI 1567 F8990441-M0569GI 1573 F8990441-M0570GI 1734 F8990441-M0571GI 1774 F8990441-M0572GI 1883 F8990441-M0573GI 1719 F8990441-M0574GI

.1761 F8990441-M0575GI 1646 F8990441-M0576GI 1345 F8990441-M0577GI 1260 F8990441-M0578GI 1323 F8990441-M0586GI 1807 F8990441-M0587GI 1737 F8990441-MO588GI 1564 F8990441-M0589GI 1555 Page 13 of 29 FSS Summary Report F8990441

F8990441-M0590GI 1801 F8990441-M0591GI 1731 F8990441-M0592GI 1789 F8990441-M0593GI 1856 F8990441-M0594GI 1853 F8990441-M0595GI 1752 F8990441-M0596GI 1749 F8990441-M0597GI 1804 F8990441-M0598GI 1734 F8990441-M0599GI 1625 F8990441-MO600GI 1841 F8990441-MO601GI 1719 F8990441-M0602GI 1655 F8990441-M0603GI 1682 F8990441-M0604GI 1704 F8990441-M0605GI 1743 F8990441-M0606GI 1655 F8990441-M0607GI 1664 F8990441-M0608GI 1649 F8990441-M0609GI 1765 F8990441-MO610GI 1618 F8990441-MO611GI 1710 F8990441-M0612GI 1771 F8990441-M0613GI 1834 F8990441-M0614GI 1728 F8990441 -M0615GI 1810 F8990441-M0616GI 1841 F8990441 -M0617GI 1740 F8990441-M0618GI 1792 F8990441-M0619GI 1850 F8990441-M0620GI 1679 F8990441-M0621GI 1904 F8990441-M0622GI 1904 F8990441 -M0623GI 1841 F8990441-M0624GI 2054 F8990441-M0625GI 2020 F8990441-M0626GI 1953 F8990441-M0627GI 2078 F8990441-M0628GI 2184 F8990441-M0629GI 2078 F8990441-M0630GI 2035 F8990441-M0631GI 2175 F8990441-M0632GI 1874 F8990441-M0633GI 2142 F8990441-M0634GI 2081 F8990441-M0635GI 2023 F8990441-M0636GI 2108 F8990441-M0637GI 2011 F8990441-M0638G[

1831 F8990441-M0639GI 1786 F8990441-M0640GI 1573 F8990441-M0641GI 1749 F8990441-M0642GI 1740 F8990441-M0643GI 1734 F8990441-M0644GI 1710 F8990441 -M0645GI 1822 Page 14 of 29 FSS Summary Report F8990441

F8990441-M0646GI 1628 F8990441-M0647GI 1695 F8990441-M0648GI 1831 F8990441-M0649GI 1892 F8990441-M0650GI 2130 F8990441-M0651GI 1895 F8990441-M0652GI 1579 F8990441-M0653GI 1737 F8990441-M0654GI 1746 F8990441-M0655GI 1692 F8990441-M0656GI 1853 F8990441-M0657GI 1725 F8990441-M0658GI 1761 F8990441-M0659GI 1698 F8990441-M0660GI 1658 F8990441-MO661GI 1716 F8990441-M0662GI 1841 F8990441-M0663GI 1704 F8990441 -M0664GI 1789 F8990441-M0665GI 1807 F8990441-M0666GI 1935 F8990441-M0667GI 2078 F8990441-M0668GI 2209 F8990441-M0669GI 2276 F8990441-M0670GI 2352 F8990441-M0671GI 2008 F8990441-M0672GI 1831 F8990441-M0673GI 1847 F8990441-M0674GI 1771 F8990441-M0675GI 1856 F8990441-M0676GI 1807 F8990441-M0677GI 1728 F8990441-M0678GI 1740 F8990441-M0679GI 1655 F8990441-M0680GI 1777 F8990441-M0681GI 1612 F8990441-M0682GI 1728 F8990441-M0683GI 1682 F8990441-M0684GI 1749 F8990441-M0685GI 1853 F8990441-M0686GI 1795 F8990441-M0687GI 1716 F8990441-M0688GI 2063 F8990441-M0689GI 2038 F8990441-M0690GI 2254 F8990441-M0691GI 2099 F8990441-M0692GI 2081 F8990441-M0693GI 1765 F8990441-M0694GI 1996 F8990441-M0695GI 1914 F8990441-M0696GI 1965 F8990441-M0697GI 1828 F8990441-M0698GI 1996 F8990441-M0699GI 1962 F8990441-MO700GI 1932 F8990441-M0701GI 1944 Page 15 of 29 FSS Summary Report F8990441

F8990441-M0702GI 1825 F8990441-M0703GI 1828 F8990441-M0704GI 1947 F8990441-M0705GI 1977 F8990441-M0706GI 1719 F8990441-M0707GI 1786 F8990441-M0708GI 1828 F8990441-M0709GI 1877 F8990441-MO710GI 1947 F8990441-MO711GI 2111 F8990441-M0712GI 2111 F8990441-M0713GI 1984 F8990441-M0714GI 2224 F8990441-M0715GI 2160 F8990441-M0716GI 2047 F8990441-M0717GI 2130 F8990441-M0718GI 2026 F8990441-M0719GI 1898 F8990441-M0720GI 2041 F8990441-M0721GI 2120 F8990441-M0722GI 2075 F8990441-M0723GI 1996 F8990441-M0724GI 2060 F8990441-M0725GI 1993 F8990441-M0726GI 1871 F8990441-M0727GI 1892 F8990441-M0728GI 1889 F8990441-M0729GI 2075 F8990441 -M0730GI 1953 F8990441-M0731GI 2078 F8990441-M0732GI 2175 F8990441-M0733GI 2078 F8990441-M0734GI 2184 F8990441-M0735GI 2209 F8990441-M0736GI 2483 F8990441-M0737GI 2446 F8990441-M0738GI 2479 F8990441-M0739GI 2343 F8990441-M0740GI 2540 F8990441-M0741GI 2738 F8990441-M0742GI 2607 F8990441-M0743GI 2568 F8990441-M0744GI 2528 F8990441-M0745GI 2832 F8990441-M0746GI 3033 F8990441-M0747GI 3030 F8990441-M0748GI 2997 F8990441-M0749GI 2945 F8990441-M0750GI 3115 F8990441-M0751GI 2966 F8990441-M0752GI 3143 F8990441-M0753GI 3109 F8990441-M0754GI 3039 F8990441-M0755GI 2997 F8990441-M0756GI 2957 F8990441-M0757GI 2732 Page 16 of 29 FSS Summary Report F8990441

F8990441 -M0758GI 2613 F8990441-M0759GI 2574 F8990441-M0760GI 2775 F8990441-M0761GI 2671 F8990441-M0762GI 2714 F8990441-M0763GI 2613 F8990441-M0764GI 2762 F8990441-M0765GI 2969 F8990441-M0766GI 2653 F8990441-M0767GI 2084 F8990441-M0768GI 2114 F8990441-M0769GI 2105 F8990441-M0770GI 2309 F8990441-M0771GI 2333 F8990441-M0772GI 2352 F8990441-M0773GI 2531 F8990441-M0774GI 2574 F8990441-M0775GI 2525 F8990441-M0776GI 2543 F8990441-M0777GI 2635 F8990441-M0778GI 2309 F8990441-M0779GI 2446 F8990441-M0780GI 2528 F8990441-M0781GI 2139 F8990441-M0782GI 2473 F8990441-M0783GI 2692 F8990441-M0784GI 2604 F8990441-M0785GI 3350 F8990441-M0786GI 3450 F8990441-M0787GI 3331 F8990441-M0788GI 3404 F8990441-M0789GI 3161 F8990441-M0790GI 3313 F8990441-M0791GI 3301 F8990441-M0792GI 2918 F8990441-M0793GI 2762 F8990441-M0794GI 2686 F8990441-M0795GI 2467 F8990441-M0796GI 2236 F8990441-M0797GI 2449 F8990441-M0798GI 2267 F8990441-M0799GI 2358 F8990441-MO800GI 2391 F8990441-MO801GI 2142 F8990441-M0802GI 1971 F8990441-M0803GI 1856 F8990441 -M0804GI 2017 F8990441-M0805GI 2136 F8990441-M0806GI 2172 F8990441-M0807GI 1828 F8990441-M0808GI 1892 F8990441-M0809GI 2203 F8990441-MO810GI 2035 F8990441-M0811GI 1856 F8990441-M0812GI 1895 F8990441-M0813GI 1792 Page 17 of 29 FSS Summary Report F8990441

F8990441-M0814GI 1816 F8990441-M0815GI 1789 F8990441-M0816GI 1774 F8990441-M0817GI 1847 F8990441-M0818GI 1920 F8990441-M0819GI 1883 F8990441-M0820GI 1901 F8990441-M0821GI 1898 F8990441-M0822GI 1941 F8990441-M0823GI 2087 F8990441-M0919GI 15281 F8990441-M0920GI 19942 F8990441-M0921GI 23274 F8990441-M0922GI 20342 F8990441-M0923GI 8970 F8990441-M0924GI 6721 F8990441-M0925GI 9327 F8990441-M0926GI 5644 F8990441-M0927GI 5229 F8990441-M0928GI 5586 F8990441-M0929GI 5123 F8990441-M0930GI 5502 F8990441-M0931GI 6227 F8990441-M0932GI 6569 F8990441-M0933GI 5996 F8990441-M0934GI 6027 F8990441-M0935GI 6064 F8990441-M0936GI 6274 F8990441-M0937GI 5638 F8990441-M0938GI 6117 F8990441-M0939GI 7378 F8990441-M0940GI 8234 F8990441-M0941GI 8981 F8990441-M0942GI 8891 F8990441-M0943GI 7157 F8990441-M0944GI 8933 F8990441-M0945GI 10068 F8990441-M0946GI 8818 F8990441-M0947GI 7798 F8990441-M0948GI 8087 F8990441-M0949GI 5991 F8990441-M0950GI 5880 F8990441-M0951GI 6059 F8990441-M0952GI 6821 F8990441-M0953GI 5675 F8990441-M0954GI 7373 F8990441-M0955GI 6432 F8990441-M0956GI 5076 F8990441-M0957GI 4698 F8990441-M0958GI 4798 F8990441-M0959GI 4987 F8990441-M0960GI 4556 F8990441-M0961GI 4840 F8990441-M0962GI 4966 F8990441-M0963GI 4966 F8990441-M0964GI 5801 Page 18 of 29 FSS Summary Report F8990441

F8990441-M0965GI 4430 F8990441-M0966GI 4393 F8990441-M0967GI 4488 F8990441-M0968GI 4388 F8990441-M0969GI 4724 F8990441-M0970GI 4729 F8990441-M0971GI 5050 F8990441-M0972GI 4971 F8990441-M0973GI 4866 F8990441-M0974GI 4635 F8990441-M0975GI 5013 F8990441-M0976GI 4934 F8990441-M0977GI 6474 F8990441-M0978GI 7215 F8990441-M0979GI 6879 F8990441-M0980GI 8082 F8990441-M0981GI 7593 F8990441-M0982GI 6432 F8990441-M0983GI 5854 F8990441-M0984GI 5318 F8990441-M0985GI 5938 F8990441-M0986GI 5218 F8990441-M0987GI 4351 F8990441-M0988GI 4036 F8990441-M0989GI 3862 F8990441-M0990GI 3799 F8990441-M0991GI 3847 F8990441-M0992GI 3484 F8990441-M0993GI 3794 F8990441-M0994GI 3994 F8990441-M0995GI 4020 F8990441-M0996GI 4262 F8990441-M0997GI 4051 F8990441-M0998GI 4898 F8990441-M0999GI 4803 F8990441-MlOOOGI 4488 F8990441-MlOOIGI 4609 F8990441-M1002GI 5234 F8990441-M1003GI 4908 F8990441-M1004GI 5244 F8990441-M1005GI 5260 F8990441-M1006GI 5512 F8990441-M1007GI 6048 F8990441-M1008GI 5008 F8990441-M1009GI 4929 F8990441-M1010GI 5250 F8990441-MlOlIGI 5187 F8990441-M1012GI 5176 F8990441-M1013GI 5696 F8990441-MI014GI 5066 F8990441-M1015GI 5455 F8990441-M1016GI 6548 F8990441-M1O17GI 4840 F8990441-MI018GI 4651 F8990441-MI019GI 5166 F8990441-MI020GI 5113 Page 19 of 29 FSS Summary Report F8990441

F8990441-MI021GI 5434 F8990441-M1022GI 5155 F8990441-M1023GI 5066 F8990441-M1024GI 4661 F8990441-M1025GI 4871 F8990441-M1026GI 5008 F8990441-M1027GI 4467 F8990441-M1028GI 4125 F8990441-M1029GI 3941 F8990441-M1030GI 4798 F8990441-M1031GI 4073 F8990441-M1032GI 4335 F8990441-Ml033GI 4193 F8990441-M1034GI 4172 F8990441-M1035GI 4771 F8990441-Ml036GI 4293 F8990441-Ml037GI 4020 F8990441-Ml038GI 4204 F8990441-Ml039GI 3715 F8990441-MI040GI 4230 F8990441-MI041GI 3810 F8990441-M1042GI 4246 F8990441-M1043GI 4277 F8990441-Ml044GI 4214 F8990441-M1045GI 4446 F8990441-M1046GI 4115 F8990441-M1047GI 4204 F8990441-MIO48GI 4157 F8990441-M1049GI 4220 F8990441-M1056GI 7830 F8990441-Ml057GI

.9785 F8990441-Ml058GI 10525 F8990441-M1059GI 5554 F8990441-M1060GI 5512 F8990441-M1061GI 5039 F8990441-Ml062GI 5670 F8990441-M1063GI 6111 F8990441-Ml064GI 6138 F8990441-Ml065GI 6679 F8990441-M1066GI 6989 F8990441-Ml067GI 6001 F8990441-M1068GI 7677 F8990441-M1069GI 8413 F8990441-M1070GI 8723 F8990441-M1071GI 7835 F8990441-Ml072GI 7704 F8990441-Ml073GI 8145 F8990441-M1074GI 7714 F8990441-M1075GI 7436 F8990441-Ml076GI 7010 F8990441-M1077GI 7851 F8990441-Ml078GI 7331 F8990441-Ml079GI 7562 F8990441-MI080GI 5008 F8990441-M1081GI 4703 F8990441-M1082GI 4566 Page 20 of 29 FSS Summary Report F8990441

F8990441-M1083GI 4714 F8990441-Mi084GI 4703 F8990441-Ml085GI 4556 F8990441-M1086GI 4325 F8990441-MI087GI 4598 F8990441-M1088GI 4335 F8990441-M1089GI 4246 F8990441-M1090GI 4325 F8990441-MI091GI 4482 F8990441-M1092GI 4251 F8990441-M1093GI 4603 F8990441-M1094GI 4630 F8990441-M1095GI 4603 F8990441-M1096GI 5055 F8990441-M1097GI 4940 F8990441-M1098GI 4813 F8990441-M1099GI 4509 F8990441-M11OOGI 4624 F8990441-M1101GI 4898 F8990441-M1102GI 4188 F8990441-M1103GI 4456 F8990441-M1104GI 4493 F8990441-M1105GI 4503 F8990441-M1I06GI 4635 F8990441-Mi107GI 4419 F8990441-M1108GI 4325 F8990441-M1109GI 4477 F8990441-MiiiOGI 4435 F8990441-M1l11GI 4393 F8990441-M1112GI 4456 F8990441-Mi113GI 4808 F8990441-MI114GI 4645 F8990441-M1115GI 4840 F8990441-M1116GI 4908 F8990441-M1117GI 4861 F8990441-MI118GI 4719 F8990441-Mi119GI 4446 F8990441-M1I20GI 4509 F8990441-MI121GI 4535 F8990441-M1122GI 4251 F8990441-MI123GI 4482 F8990441-MI124GI 4404 F8990441-Mi125GI 4913 F8990441-MI126GI 4388 F8990441-M1127GI 4661 F8990441-M1128GI 4566 F8990441-M1I29GI 4509 F8990441-M1130GI 8707 F8990441-MI131GI 11855 F8990441-Mi132GI 12491 F8990441-Mi133GI 5665 F8990441-M1I34GI 6637 F8990441-M1135GI 11566 F8990441-M1136GI 5854 F8990441-M1137GI 4982 F8990441-M1138GI1 5413 Page 21 of 29 FSS Summary Report F8990441

F8990441 -M 1139GI 5365 F8990441-M1140GI 5197 F8990441-M1141GI 4540 F8990441-M1142GI 5239 F8990441-M1143GI 5843 F8990441-M1144GI 5160 F8990441-M1145GI 5533 F8990441-M1146GI 5402 F8990441-M1147GI 5160 F8990441-M1148GI 5733 F8990441-M1149GI 5360 F8990441-M1150GI 5528 F8990441-MI151GI 5376 F8990441-M1152GI 5533 F8990441-M1153GI 5544 F8990441-M1154GI 5113 F8990441-M1155GI 5239 F8990441 -M1156GI 5418 F8990441-M1157GI 5271 F8990441-M1158GI 5859 F8990441-M1159GI 5828 F8990441-M1160GI 5160 F8990441-M1161GI 5250 F8990441-M1162GI 5439 F8990441-M1163GI 4934 F8990441-M1164GI 4656 F8990441-M1165GI 5334 F8990441-M1166GI 4235 F8990441-M1167GI 4729 F8990441-M1168GI 4582 F8990441-M1169GI 4813 F8990441-M1170GI 4388 F8990441-MI171GI 4298 F8990441-M1172GI 4803 F8990441-M1173GI 4335 F8990441-M1174GI 4377 F8990441-M1175GI 4409 F8990441-M1176GI 4115 F8990441-M1177GI 4388 F8990441-M1178GI 7657 F8990441 -M 1179GI 8767 F8990441 -M 1180GI 10264 F8990441-M1181GI 12299 F8990441-M1182GI 13571 F8990441-M1183GI 13233 F8990441-M1184GI 12141 F8990441-M1185GI 10522 F8990441-M1186GI 10027 F8990441-M1187GI 9528 F8990441-M1189GI 15354 F8990441-MI190GI 15771 F8990441-M1191GI 14180 F8990441-M1192GI 9941 F8990441-M1193GI 6345 F8990441-M1194GI 5435 F8990441-M1195GI 5194 Page 22 of 29 FSS Summary Report F8990441

F8990441-MI196GI 6938 F8990441-M1197GI 6656 F8990441-M1198GI 6857 F8990441-M1199GI 7495 F8990441-M1200GI 7454 F8990441-MI201GI 7188 F8990441-M1202GI 7055 F8990441-M1203GI 7033 F8990441-M1204GI 7814 F8990441-M1205GI 8579 F8990441-M1206GI 8242 F8990441-M1207GI 8059 F8990441-M1208GI 8048 F8990441-M1209GI 8953 F8990441-MI210GI 9612 F8990441-MI211GI 9672 F8990441-M1212GI 10203 F8990441-M1213GI 11079 F8990441-M1214GI 11060 F8990441-M1215GI 9492 F8990441-M1216GI 8775 F8990441-M1217GI 8866 F8990441-M1218GI 8265 F8990441-M1219GI 6287 F8990441-M1220GI 5311 F8990441-M1221GI 5322 F8990441-M1222GI 8759 F8990441-M1223GI 8561 F8990441-M1224GI 8389 F8990441-M1225GI 8046 F8990441-M1226GI 7588 F8990441-M1227GI 4728 F8990441-M1228GI 4308 F8990441-M1229GI 4204 F8990441-M1230GI 7525 F8990441-M1231GI 8948 F8990441-M1232GI 6171 F8990441-M1233GI 5323 F8990441-M1234GI 5426 F8990441-M1235GI 7354 F8990441-M1236GI 7454 F8990441-M1237GI 7288 F8990441-M1238GI 7292 F8990441-M1239GI 7297 F8990441-M1240GI 7680 F8990441-M1241GI 7894 F8990441-M1242GI 8382 F8990441-M1243GI 8607 F8990441-M1244GI 8677 F8990441-M1245GI 8523 F8990441-M1246GI 8664 F8990441-M1247GI 9231 F8990441-M1248GI 9989 F8990441-M1249GI 9634 F8990441-M1250GI 7966 F8990441-M1251GI 6279 Page 23 of 29 FSS Summary Report F8990441

F8990441-M1252GI 7146 F8990441-M1253GI 10105 F8990441 -Ml 254GI 10711 F8990441-M1255GI 10719 F8990441-M1256GI 10368 F8990441-M1257GI 10187 F8990441-M1258GI 10870 F8990441-M1259GI 11898 F8990441-M1260GI 11888 F8990441-M1261GI 11785 F8990441-M1262GI 11202 F8990441-M1263GI 10820 F8990441-M1264GI 10823 F8990441-M1265GI 11045 F8990441-M1266GI 12154 F8990441-M1267GI 12603 F8990441-MI268GI 12601 F8990441-M1269GI 11659 F8990441-M1270GI 11529 F8990441-M1271GI 11136 F8990441-M1272GI 10432 F8990441-M1273GI 9582 F8990441-M1274GI 8293 F8990441-M1275GI 7192 F8990441-M1276GI 5449 F8990441-M1277GI 5209 F8990441-M1278GI 5501 F8990441-M1279GI 8198 F8990441-M1280GI 10172 F8990441-M1281GI 11495 F8990441-M1282GI 12973 F8990441-M1283GI 12469 F8990441-M1284GI 9274 F8990441-M1287GI 6925 F8990441-M1288GI 4901 F8990441-M1289GI 5033 F8990441-M1290GI 5109 F8990441-M1291GI 5353 F8990441-M1292GI 5393 F8990441-M1293GI 5327 F8990441-M1294GI 5819 F8990441-M1295GI 6486 F8990441-M1296GI 5756 F8990441-M1297GI 5446 F8990441-M1298GI 5730 F8990441-M1299GI 5822 F8990441-M1300GI 5479 F8990441-MI301GI 5261 F8990441-M1302GI 4574 F8990441-M1303GI 4620 F8990441-M1304GI 5373 F8990441-M1305GI 5291 F8990441-M1306GI 5182 F8990441-M1307GI 5175 F8990441-M1308GI 4881 F8990441-M1309GI 4980 Page 24 of 29 FSS Summary Report F8990441

F8990441-MI310GI 4944 F8990441-MI311GI 5363 F8990441-M1312GI 5532 F8990441-M1313GI 5390 F8990441-M1314GI 5651 F8990441-M1315GI 4858 F8990441-M1316GI 4756 F8990441-M1317GI 4855 F8990441-M1318GI 4934 F8990441-M1319GI 4742 F8990441-M1320GI 4835 F8990441-M1321GI 4865 F8990441-M1322GI 4974 F8990441-M1323GI 4795 F8990441-M1324GI 4732 F8990441-M1325GI 4706 F8990441-M1326GI 4785 F8990441-M1327GI 4597 F8990441-M1328GI 4812 F8990441-M1329GI 4571 F8990441-M1330GI 4571 F8990441-M1331GI 4822 F8990441-M1332GI 5020 F8990441-M1333GI 4875 F8990441-M1334GI 4633 F8990441-Ml335GI 4802 F8990441-M1336GI 4931 F8990441-M1337GI 4875 F8990441-M1338GI 4941 F8990441-M1339GI 5007 F8990441-M1340GI 5089 F8990441-M1341GI 5419 F8990441-M1342GI 5099 F8990441-M1343GI 5159 F8990441-M1344G1 5291 F8990441-M1345GI 5370 F8990441-M1346GI 5505 F8990441-M1347GI 5842 F8990441-M1348GI 5657 F8990441-M1349GI 5221 F8990441-MI350GI 5218 F8990441-M1351GI 4911 F8990441-M1352GI 4485 F8990441-M1353G1 4174 F8990441-M1354GI 4531 F8990441-M1355GI 4409 F8990441-M1356GI 4515 F8990441-M1357GI 4297 F8990441-M1358GI 4587 F8990441-M1359GI 4425 F8990441-Ml360GI 4983 F8990441-M1361GI 5096 F8990441-M1364GI 4719 F8990441-M1365GI 5376 F8990441-M1366GI 5297 F8990441-M1367GI 4687 Page 25 of 29 FSS Summary Report F8990441

F8990441-M1368GI F8990441-M1375GI F8990441-M1376GI F8990441-MI377GI F8990441-M1378GI F8990441-M1379GI F8990441-M1380GI F8990441-M1381GI F8990441-MI389GI F8990441-M1390GI F8990441-M1391GI F8990441-M1392GI F8990441-M1393GI F8990441-M1394GI F8990441-MI395GI F8990441-MI396GI F8990441-M1397GI F8990441-M1398GI F8990441-MI399GI F8990441-M1400GI F8990441-M1401GI F8990441-M1402GI F8990441-M1403GI F8990441-M1404GI F8990441-M1405GI F8990441-M1406GI F8990441-M1407GI Mean:

Median:

Standard Deviation:

Range:

4635 3343 6406 6723 7989 12523 16015 14637 5145 5125 4983 4983 4752 4851 5188 5063 5201 4805 2400 2492 1768 1950 2169 4838 2365 2442 4120 4040 2852 2885 1'260 - 26111 Page 26 of 29 FSS Summary Report F8990441

Survey Unit Data Assessment:

The survey design required 1243 direct measurements for the Sign Test. The critical value and the results of the Sign Test are presented in Table 4. The sample mean and median values were less than the DCGL. The sample standard deviation was less than the design standard deviation so no additional samples were required.

Page 27 of 29 FSS Summary Report F8990441

Table 4. Data Assessment Results Survey Results Parameter Value Comment Material Background Used (dpm/100 cm 2):

N/A Ambient Background Used (dpm/100 cm 2):

N/A Average Ambient BKG = 0 Actual Direct Measurements (N):

1243 Median (dpm/100 cm 2):

2852 Mean (dpm/100 Cm2):

4040 Direct Measurement Standard Deviation 2885 (dpm/lO0 cm2):

Total Standard Deviation (dpm/100 cm 2):

2885 Based on samples and backgrounds.

Maximum (dpm/100 cm 2):

26111 Material Type:

N/A Background Subtract Not Applied Sign Test Final N Value:

1243 S+ Value:

1243 Critical Value:

650 Sufficient Samples Collected:

Yes Maximum Value < DCGL:

Yes Median Value < DCGL:

Yes Mean Value < DCGL:

Yes Maximum Value < DCGLemc:

Yes Class 1 Total Standard Deviation <= Sigma:

Yes Pass the Sign Test?

Yes Reject the Null Hypothesis?

Yes Does the Survey Unit Pass All Criteria?

Yes Page 28 of 29 FSS Summary Report F8990441

Survey Unit Investigations and Results:

No investigations were required and no investigation results are reported.

ALARA Statement:

As stated in Chapter 4 of the LTP, as long as the residual activity within the survey unit is less than the DCGL (i.e. the survey unit average activity is less than the DCGL and the EMC criterion has been met), the ALARA criterion has been met.

Changes in Initial Survey Unit Assumptions:

The survey unit was designed as a Class 1 structure survey and the sample results are consistent with that classification. The variability of the survey results was less than the characterization data used for survey design. No potential areas of elevated activity were detected.

==

Conclusion:==

The FSS of this survey unit was properly designed as a Class 1 survey based on Table 5-4 of the LTP. The required number of direct measurements was made and the scan coverage met the requirement of the LTP for pipe surveys. No direct measurements exceeded the DCGL of 100000 dpm/100 cm2. No investigations were required.

The direct measurement data support rejection of the null hypothesis, providing high confidence that the survey unit satisfied the release criteria and -.hat the data quality objectives were met.

It is concluded that survey unit F8990441 meets the release criteria of 10CFR20.1402.

Page 29 of 29 FSS Summary Report F8990441 Maps November 17, 2008 Survey Unit F8990441

0 II FUEL STORAGEl ZE 3 UILDINGr 11 I ° KEY PLAN CONT AT LEFT PLAN VIEW BELOW EL. 0'-0" PLAN VIEW rl -O'-O" TO AO'-Q" I0 00

  • SMUD SACRAMENTO MUNICIPAL UTILITY DISTRICT SPENT LEAK FUEL BUILDING CHASE PIPING 0

.5 1

2 SCALE METERS F8990441 -M1 SHEET 1 OF 6 RC RAYMOND FILE: F899044

0 00 FUEL STORA E 0 =0 BUILDING 0 ]

KEY PLAN 11.

4'-6' 4'-6 1-1

-1 0.5 1 2

SCALE METERS SPENT FUEL BUILDING COOLING & FILL PIPING

  • SMUD SACRAMENTO MUNICIPAL UTILITY DISTRICT F8990441 -Ml SHEET 2 OF 6

0 0

p 00 0

S**

FUEL STORAGE]

0'm[ BUILDING KEY PLAN 2-o.5 1 2

SCALE METERS SPENT FUEL BUILDING FLOOR DRAIN PIPING c

T.,

SACRAMENTO MUNICIPAL UTILITY DISTRICT F8990441 -M 1 3 OF 6

(J,1 0

0 FUEL STORAGE1 S73 0 BUILDING KEY PLAN 0

.5 1

2 SCALE METERS SPENT FUEL BUILDING FILTER RETURN PIPING

  • SMU SACRAMENTO MUNICIPAL UTILITY DISTRICT F8990441 -M 1

oD L~ I !rf BIDING EYJ 0PLN KEY PLAN 00

ý,0 o.5 1

2 N

SCALE METERS smuc SACRAMENTO MUNICIPAL UTILITY DISTRICT SPENT FUEL BUILDING SKIMMER PIPING F8990441 -M 1 SHEET 5 OF 6 SCALE METERS PLAN VIEW EL. 0'-0" TO 4,'-O" FIL...........

RC RAYMOND FILE: F899044

CD 0

c-*

FUEL STORAGE

=

BUILDING KYII IP I

KEY PLAN PLAN VIEW It00 S

SMUD SACRAMENTO MUNICIPAL UTILITY DISTRICT SPENT FUEL BUILDING DECAY HEAT PIPING F8990441 -M 1 SHEET 6 OF 6 0

.5 1

2 SCALE METERS FILE: F899011 RC RAYMOND

00 00 PIPING

SUMMARY

SIZE 225L 6S 1"o 225 LF 6 SM

  • SMUn SACRAMENTO MUNICIPAL UTILITY DISTRICT SPENT FUEL BUILDING LEAK CHASE PIPING ISOMETRIC F8990441 -M2 SHEET 1 OF 6

0C cjn 00 C,*

PIPING SUMWARY 2.5'o 35 LF 3 SM 2"o 120 LF 6 SM

.75"0 40 LF 1 SM

  • SMUI SACRAMENTO MUNICIPAL UTILITY DISTRICT SPENT FUEL BUILDING FILTER RETURN PIPING ISOMETRIC F8990441 -M2 SHEET 2 OF 6 RC RAYMOND FILE.: F8g9044

-o 0

lye ITJ 00 O0 C:

SPENT FUEL BUILDING PIPING

SUMMARY

5U LE:NG - EL 3"o 45 LF 4 SM 2.5"o 100 LF 6 SM

  • SMUI SACRAMENTO MUNICIPAL UTILITY DISTRICT SPENT FUEL BUILDING SKIMMER PIPING ISOMETRIC F8990441 -M2 I......

SHEET 3 OF 6 RC RAYMOND E

V ~~~FILE:

F899044 SET3O

0 0I 00

/11 9->

op PIPING

SUMMARY

SZaE LEN G Kh 12*0 1 LF

.3 SM 8"o 55 LF 11 SM 3"o 7 LF

.5 SM

  • smu SACRAMENTO MUNICIPAL UTILITY DISTRICT SPENT FUEL BUILDING COOLING & FILL PIPING ISOMETRIC F8990441 -M2 SHEET 4 OF 6 FILE. F899044 RC RAYMOND

0 1yo

.l.ký 1

.0 9 00 PIPING

SUMMARY

Suz LNTH AREA 2*0 160 LF 8 SM 1"o 15 LF

.5 SM 0-0 00

-REMOVED SMUD SACRAMENTO MUNICIPAL UTILITY DISTRICT SPENT FUEL BUILDING FLOOR DRAIN PIPING ISOMETRIC F8990441 -M2 99044 SHEET 5 OF 6 RC RA FILE: F8

,YMOND

0 0

U)

K d

\\

fI 5.1 1-'

00

ýo PIPING

SUMMARY

1 5a LN A2KA 16"o 5 LF 2 SM

  • smuo SACRAMENTO MUNICIPAL UTILITY DISTRICT SPENT FUEL BUILDING DECAY HEAT PIPING ISOMETRIC F8990441 -M2 SHEET 6 OF 6 RC RAYMOND FILE. F899011 Instrumentation November 17, 2008 Survey Unit F8990441

Table 2-1. Survey Unit Instrumentation Instrument Detector MDC Static MDC Scan Model; Serial No.

Model; Serial No.

(dpm/100.m 2)

(dpm/100 cm2)

M2350; 189081 PIPEMON; B821Z 4680 N/A M2350; 142514 PIPEMON; B821Z 4680 N/A M2350; 142512 44-162; L206935 1550 N/A M2350; 189081 44-159; 238368 5720 N/A M2350; 142512 44-159; 201637 5720 N/A M2350; 180733 43-94B; 148620 800 N/A The MDC's listed are the most conservative for the survey performed.

Table 2-2. Investigation Criteria and DCGL Value ParameterVau (dpm/100) cm 2)

Investigation Criteria - Direct 100000 Investigation Criteria - Scan N/A DCGLw 100000 DCGLEMC N/A

-Page 2 of 2 Att. 2 Instrumentation F8990441 Investigation November 17, 2008 Survey Unit F8990441 (none required)

Data Assessment November 17, 2008 Survey Unit F8990441

CF8990441 Gross Activity Sample Results Quantile Plot 0

DCGL = 100000 dpm/1OOcm 2 30,000 f-71, U U U

M*

10,000

=.A$

.2852 0

20 40 60 80 100

~Percentile 00

-'irect<t-mesre et (dpm/00cm2 mda 75t Perenil 50t Pecntl

CD z

0

'-n

>D

'En CD F8990441 Gross Activity Sam pie Results Scatter Plot DCGL = 100000 dpmllOOcm2 E

0 0

E 30000 25000 20000 15000 10000 5000 0

-5000

-10000 12693 4040

-4614

  • uuuuuuuuuuuuuuuuuumuuuuunuuuuuuuuuuu~uuuuumuhuuu E Ia 09(3(9000 (

o 0

V'-

20 00 3n00 22 2 O 2

Ma M V mt0 0

w N

) a Nc3 n~

0 0 a aW C3~

aNa)a Measurement Locations 00

%-CT am Nto) t-r-

0000

]tCU r

r r

It00 01 I )

Gross Activity -

Average -

'+SStDev "

"- 330ev "I

0 Cj2 00 F8990441 Gross Activity Frequency Plot DCGL = 100000 dpm/1 00crn2 C

U-0 PMi 760 720 680 640 600 560 520 480 440 400 360 320 280 240 200 160 120 80 40 0

0 0

0)

Bins - Upper End Value (dpm/1 00cm2)