Rancho Seco Final Status Survey Summary Report September 26, 2008 Demin RC Storage Tank Pad Survey Unit F8100042 Prepared By: Dan A. Tallman,Date:
September 26, 2008 FSS Endineer Reviewed By:
f(1*
(O9 Lead FSS Engineer Approved By:
Date:
2, 0-0 Dismantlement Superintendent, Radiological
FINAL STATUS SURVEY
SUMMARY
REPORT Survey Unit:
F8100042, Demin RC Storage Tank Pad Survey Unit
Description:
Operating History: This area commonly referred to as the Tank Farm, surrounded the tanks used to store radioactive liquids. The Demin RC Storage Tank Pad resides within the boundaries of the Tank Farm and has been used for the storage of radioactive material. Operating records and the HSA document several events with the potential for a release of radioactivity associated with this survey area. The HSA documented the storage of radioactive material within the area that may have had the potential to contaminate the area.
Site Characterization: Gamma scan measurements were made of the Demin RC Storage Tank Pad using the HPGe detector and the ISOCS system. These measurements confirmed the presence of plant-derived radionuclides. Scan measurements of the Demin RC Storage tank showed a mean gross activity level of 987 dpm/1 00 cm 2 and a maximum value of 1,120 dpm/100 cm. Based on the classification procedure (DSIP-0020) and levels of activity reported, the area was determined to be a Class 2 area.
Survey Unit Design Information:
The Survey Unit Design Parameters are presented in Table 1 below. The survey unit and measurement locations are depicted on the maps in Attachment 1. Direct measurement locations were determined using a random-start, fixed grid pattern and 84 m2 were scanned for approximately 47% coverage. Samples of removable contamination were collected at each direct measurement location. The instrumentation used for the survey along with the MDC values are listed in Tables 2-1 and 2-2 in Attachment 2.
Page 2 of 8 FSS Summary Report F8100042
Table 1. Survey Unit Design Parameters Survey Design Value Comment Parameter Survey Area:
F810 Survey Unit:
Class:
SU Area (mn 2):
Evaluator:
DCGL (dpm/1 00 cm 2):
, Area Factor:
Design DCGLemc (dpm/100 cm 2):
LBGR (dpm/100 cm 2):
Design Sigma (dpm/100 cm 2):
Type I Error:
Type II Error:
Predominant Nuclide:
Sample Area (M2):
Scan Area (M 2):
Scan Coverage (%):
Zl_* :
Sign P:
Calculated Relative Shift:
Relative Shift Used:
N-Value:
Design N-Value + 20%:
Design Min Samples N:
Grid Spacin2 L:
0042 2
177.4 D.A.Tallman 43000 N/A N/A 21500 73 0.05 0.05 Cs-137 12.6 84 47%
1.645 1.645 0.99865 294.5 3
11 14 14 3.5 Detain RC Storage Tank Pad Structure Surface LTP Table 5-4 Gross Activity DCGL Class 2 Class 2 Default = 50% DCGL Class 2 Class 2 Uses 3.0 if Relative Shift is
>3 NUREG-1575 Table 5-5 Class 2 Class 2 Page 3 of 8 FSS Summary Report F8100042
Survey Results:
A total of 16 direct measurements were made in F8100042. The results including mean, median, standard deviation and range are shown in Table 2. All direct measurements were less than the DCGL. None of the scan measurements indicated areas of elevated activity. Scan activity ranged from 3810 to 17650 dpm/1 00 cm2, based on a surveyor efficiency of 0.5 and no background subtracted. Samples for removable surface activity were all less than 10% of the DCGL as shown in Table 3. Removable surface activity samples were counted for alpha activity and none was detected at the MDC shown in Table 2-1 of Attachment 2.
Table 2. Direct Measurement Results Measurement ID Gross Activity (dpm/100 cm F8100042-CO001BD 4373 F8100042-CO002BD 4560 F8100042-CO003BD 36.93 F8100042-CO004BD 3641 F8100042-CO005BD 3470 F8100042-CO006BD 4082 F8100042-CO007BD 3890 F8100042-CO008BD 3294 F8100042-CO009BD 3756 F8100042-CO01 OBD 4274 F8100042-CO011 BD 3750 F8100042-CO012BD 3616 F8100042-CO013BD 3206 F8100042-CO014BD 3849 F8100042-CO015BD 3097 F8100042-CO016BD 2811 Mean:
3710 Median:
3722 Standard Deviation:
473 Range:
2811 -4560 Page 4 of 8 FSS Summary Report F8100042
Table 3. Removable Surface Activity Results Measurement ID Surface Beta Activity (dpm/100 cm 2)
F8100042C0001SM F8100042C0002SM F8100042C0003SM F8100042C0004SM F8100042C0005SM F8100042C0006SM F8100042C0007SM F8100042C0008SM F8100042C0009SM F8100042C0010SM F8100042C0011 SM F8100042C0012SM F8100042C001 3SM F8100042C0014SM F8100042C001 5SM F8100042C0016SM Mean:
Median:
Standard Deviation:
Ranqe:
-0.95
-2.24
-3.53
-6.11
-0.95
-3.53
-0.95
-4.82
-3.53
-3.53
-2.24
-2.24
-4.82
-4.82
-4.82 10.68
-2.4
-3.53 3.83
-6.11 to 10.68 Page 5 of 8 FSS Summary Report F8100042
Survey Unit Data Assessment:
The survey design required 16 direct measurements for the Sign Test. The critical value and the results of the Sign Test are presented in Table 4. The sample mean and median values were less than the DCGL. The sample standard deviation was greater than the design standard deviation. However, since both values of sigma resulted in a relative shift greater than three (3), no additional samples were required.
Page 6 of 8 FSS Summary Report F8100042
Table 4. Data Assessment Results Survey Results Parameter Value Comment Material Background Used (dpm/100 cm 2):
Ambient Background Used (dpm/100 cm 2):
Actual Direct Measurements (N):
Median (dpm/100 cm 2):
Mean (dpm/100 Cm2):
Direct Measurement Standard Deviation (dpm/100 cm 2):
Total Standard Deviation (dpm/100 cm 2):
Maximum (dpm/100 cm 2):
Material Type:
Sign Test Final N Value:
S+ Value:
Critical Value:
Sufficient Samples Collected:
Maximum Value < DCGL:
Median Value < DCGL:
Mean Value < DCGL:
Maximum Value < DCGLemc:
Total Standard Deviation <= Sigma:.
Pass the Sign Test?
Reject the Null Hypothesis?
Does the Survey Unit Pass All Criteria?
N/A N/A 16 3722 3710 473 473 4560 N/A 16 16 11 Yes Yes Yes Yes N/A Investigate Yes Yes Yes Average Ambient BKG = 0 Based on samples and backgrounds.
Background Subtract Not Applied Class 2 Both values of sigma result in relative shift greater than three so no additional samples required Sufficient sample were taken Page 7 of 8 FSS Summary Report F8100042
Survey Unit Investigations and Results:
No investigations were required for either direct or scan measurements and no investigation results are reported.
ALARA Statement:
As stated in Chapter 4 of the LTP, as long as the residual activity within the survey unit is less than the DCGL (i.e. the survey unit average activity is less than the DCGL and the EMC criterion has been met), the ALARA criterion has been met.
Changes in Initial Survey Unit Assumptions:
The survey unit was designed as a Class 2 structure survey and the sample results are consistent with that classification. The variability of the survey results was greater than the characterization data used for survey design. However, no additional samples were required. No potential areas of elevated activity were detected.
==
Conclusion:==
The FSS of this survey unit was properly designed as a Class 2 survey based on Table 5-4 of the LTP. The required number of direct measurements was made and the scan coverage met the requirement of Table 5-6 of the LTP. No direct measurements 6xceeded the DCGL of 43000 dpm/100 cm 2 and none of the removable surface activity measurements exceeded 10% of the DCGL. No investigations were required.
The direct measurement data support rejection of the null hypothesis, providing high confidence that the survey unit satisfied the release criteria and that the data quality objectives were met.
It is concluded that survey unit F8100042 meets the release criteria of 1 OCFR20.1402.
Page 8 of 8 FSS Summary Report F8100042 Maps September 26, 2008 Survey Unit F8100042
C
-DRCSTPAD 0
0
-II I PAD BWSTPAD Zone 3 i
Asphalt Zone1
<4\\
,Ti.
Reactor 00Reco TANK FARM-CONCRETE PADS GENERALpARRANGEMENT W
~
PLAN VIEW SACRAMENTO MUNICIPAL UTILITY DISTRICT F8100043-Ml SHEET 1 OF 2
(tI 0
cc c::>
00 3-,N Vertical Surface Details Surlace Area Estimates concrete 176.1 r steel 1 3mrr Total 1 774ma Scale Feet 8J"=1'0 Scale Meters 0
1 2
3 SMUM SACRAMENTO MUNICIPAL UTILITY DISTRICT TANK FARM - DRCST PAD PLAN / ELEVATION VIEW SURFACE AREA ESTIMATE F8100042-Mi SHEET 2 of2
-r't
-4 00 0
- ; i ~ l I l l ',
.. c..........
. I........
...T
+ +, ', + ; ; I l I, t ' ' ' ' ' '.
I A-.
A-_
+..
......... +.
....:i+
4 I
A t
L N
- 11. 11!11 1t 1 H HIHH !
H i l.l/,
.. II II I...
11.-
I.
+/-
H
+
+/-+/-+
4:
T
+
T T_+
+
+
+
ti
_;ll IT i,
+1~
+
+
+
-u
+
+
4:
4:$
4*
+/-A
+
T
+/-+
T T
+T A
I-
+
+/-
, +
.+
A.H I
H+F+HHHH.]-H.AIrHI-i-++/-H÷i if A
il 1~
!wifil 111.-
'1! 111 Tt T
A DOSTAD M-DRCSTPAA
+
T T:
T
+
+
a UTILIT DITIT F8 0042M SHE 1 T1
N It~
(Dl 0
GD GD 10 9
relocated 1 foot south 1I'*5" DRCST PAD 171 00 Scale Feet 81" Scale Meters 0
1 2
- -MU SACRAM~ENTO M1UNICIPAL UTILITY DISTRICT TANK FARM - DRCST PAD BETA DIRECT MEASUREMENT LOCATIONS F8100042-M2 SHEET 2 of2
0
-Il 00 Scale Feet Scale Meters 0
1 2
3 SMUM SACRAMENTO MUNICIPAL UTILITY DISTRICT TANK FARM - DRCST PAD BETA SCAN MEASUREMENT LOCATIONS F8100042-M3 SHEET 1 of2
00(1' 0
cj~
00 Z/
/N ~
~Iz Scale Feet 1"= 1,-0" Scale Meters 0
1 2
3 5muc SACRAMENTO MUNICIPAL UTILITY DISTRICT TANK FARM - DRCST PAD GAMMA SCAN MEASUREMENT LOCATIONS F8100042-M3 SHEET 2 of 2 Instrumentation September 26, 2008 Survey Unit F8100042
Table 2-1. Survey Unit Instrumentation Instrument Detector MDC Static MDC Scan Model; Serial No.
Model; Serial No.
(dpm/100 cm2 )
(dpm/100 cm2 )
M2350;, 193700 43-68B; 160691 433 1033 M2350; 142499 43-37; 148502 N/A 616 Tennelec; 0401171 N/A 6 dpm a, 12 dpmI3 N/A Table 2-2. Investigation Criteria and DCGL Value Parameter VleC2 (dpm/100 cm 2)
Investigation Criteria - Direct 43000 Investigation Criteria - Scan 43000 DCGLw 43000 DCGLEmc N/A Page 2 of 2 Att. 2 Instrumentation F8100042 Investigation September 26, 2008 Survey Unit F8100042 (none required)
Page I of I Att. 3 Investigation F8100042 Data Assessment September 26, 2008 Survey Unit F8100042
0.
Ci2 C/)
F8100042 Gross Activity Sample Results Quantile Plot DCGL = 43000 dpm/1 00cm2 5,000 4,500 4,000 3,500 3,000 2,500 2,000 1,500 1,000 500 0
3722 0
20 40 60 Percentile 80 100 Direct Measurements (dpm/100cm2) -
median -
- 75th Percentile....
50th Percentile
CD F8100042 Gross Activity Sample. Results Scatter Plot DCGL = 43000 dpmlO00cmR 6000 -
- -5000 --
51 29 E
0 U
0 0
CL 3°000 -
(42-0-o
_i 3710 CE 0
a3000 o
C2000-a0 0-V-
It V-V-
T-00 0
0 o
0 0
0 0
0 0
0 r
r r-r r
S v-0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
Measurement Locations Oo i o Gross Activity i-Average -
"+3StDev" -
"-3StDev "I I'J:
C)"
(D (jD (D
00 C)
F8100042 Gross Activity Frequency Plot DCGL = 43000 dprn/1 00cm2 0
4-7 6
,5 4
3 2
1 0
q9 Bins - Upper End Value (dpm/1 00cm2)