Correction of Technical Specification Pages Previously Approved by Amendment
ML090420061
Person / Time
Site: South Texas  
Issue date: 02/04/2009
From: Harrison A
South Texas
To:
Document Control Desk, Office of Nuclear Reactor Regulation
References
NOC-AE-09002390, TAC MD7058, TAC MD7059
Download: ML090420061 (8)


Text

Nuclear Operating Company South Texas Project Electric GeneratinS Station PO Box 289 Wadsworth Texas 77483

_AV_--

February 4, 2009 NOC-AE-09002390 10 CFR 50.90 U.S. Nuclear Regulatory Commission ATTN: Document Control Desk One White Flint North 11555 Rockville Pike Rockville, MD 20852 South Texas Project Units 1 and 2.

Docket No. STN 50-498, STN 50-499 Correction of Technical Specification Pages Previously Approved by Amendment

Reference:

Letter from Mohan C. Thadani to Edward D. Halpin dated October 31, 2008, "South Texas Project, Units 1 and 2 - Issuance of Amendments to Relocate Surveillance Test Intervals to Licensee-Controlled Program (Risk-Informed Initiative 5-b) (TAC Nos. MD7058 and MD7059)" (ML082830172)

The Nuclear Regulatory Commission (NRC) issued amendments 188/175 referenced above to Operating Licenses NPF-76 and NPF-80 for implementation at South Texas Project Units 1 and

2. STP Nuclear Operating Company (STPNOC) subsequently identified administrative errors on four pages in which changes incorporated by previous amendments were not carried over to amendments 188/175, as well as a typographical error on an additional page.

STPNOC requests that the affected pages be re-issued with the errors corrected as incorporated on the attached pages.

There are no new commitments in this letter.

If there are any questions or if additional information is needed, please contact either Mr. Ted Koser at (361) 972-8963 or me at (361) 972-7298.

anager, Licensing

Attachment:

Corrected Technical Specification Pages STI 32427737

NOC-AE-09002390 Page 2 of 2 cc:

(paper copy)

(electronic copy)

Regional Administrator, Region IV U. S. Nuclear Regulatory Commission 612 East Lamar Blvd, Suite 400 Arlington, Texas 76011-4125 Richard A. Ratliff Department of State Health Services Inspection Unit - Radiation Branch P.O. Box 149347 Austin, TX 78714-9347 C. M. Canady City of Austin Electric Utility Department 721 Barton Springs Road Austin, TX 78704 Mohan C. Thadani Senior Project Manager U.S. Nuclear Regulatory Commission One White Flint North (MS 7 D1) 11555 Rockville Pike Rockville, MD 20852 Senior Resident Inspector U. S. Nuclear Regulatory Commission P. O. Box 289, Mail Code: MN116 Wadsworth, TX 77483 Kevin Howell Catherine Callaway Jim von Suskil NRG South Texas LP Ed Alarcon J. J. Nesrsta R. K. Temple Kevin Polio City Public Service Jon C. Wood Cox Smith Matthews C. Kirksey City of Austin A. H. Gutterman, Esquire Morgan, Lewis & Bockius LLP Mohan C. Thadani U..S. Nuclear Regulatory Commission

ATTACHMENT CORRECTED TECHNICAL SPECIFICATION PAGES Page 3/43-44 3/4 3 -49 3/4 5 - 1 3/45-4 3/4 8 - 13a Correction Removed Modes 5 and 6 for RCB purge surveillance Removed asterisked note Corrected "GRMP" reference to "CRMP" (TS 3.5.1.b)

Removed specific sump components (SR 4.5.2.d)

Removed reference to movement of irradiated fuel (TS 3.8.2.2.b, second bullet)

W, 0

C

__I CA C:,

3 3 (D (D

3 :3 z z 00 TABLE 4.3-2 (Continued)

ENGINEERED SAFETY FEATURES ACTUATION SYSTEM INSTRUMENTATION SURVEILLANCE REQUIREMENTS CHANNEL FUNCTIONAL UNIT CHANNEL CHANNEL CHECK(9)

CALIBRATION(9)

DIGITAL OR ANALOG CHANNEL OPERATIONAL TEST(7)(9)

TRIP ACTUATING DEVICE OPERATIONAL TEST(9)

ACTUATION LOGIC TEST(9)

MASTER RELAY TEST(9)

SLAVE RELAY TEST(9)

MODES FOR WHICH SURVEILLANCE IS REQUIRED

3. Containment Isolation (Continued)
3) Safety Injection
4) RCB Purge Radioactivity-High
5) Containment Spray -

Manual Initiation

6) Phase "A" Isolation-Manual Initiation
c. Phase "B" Isolation
1) Automatic Actuation Logic
2) Actuation Relays
3) Containment Pressure--High-3
4) Containment Spray-Manual Initiation
d. RCP Seal Injection Isolation
1) Automatic Actuation Logic and Actuation Relays
2) Charging Header Pressure - Low

'Coincident with Phase "A" Isolation See Item 1. above for all Safety Injection Surveillance Requirements.

N.A.

N.A.

N.A.

N.A.

1,2,3,4 See Item 2. above for Containment Spray manual initiation Surveillance Requirements.

See Item 3. a. above for Phase "A" Isolation manual initiation Surveillance Requirements.

N.A.

N.A.

N.A.

N.A.

N.A.

N.A.

N.A.

N.A.

N.A.

(1)

N.A.

N.A.

N.A.

(6)

N.A.

N.A.

1,2,3,4 (8) 1,2,3,4 N.A.

1,2,3 See Item 2. above for Containment Spray manual initiation Surveillance Requirements.

N.A.

N.A.

N.A.

N.A.

N.A.

N.A.

N.A.

(8) 1, 2, 3, 4 N.A.

1,2,3,4 N.A.

See Item 3.a. above for Phase "A" surveillance requirements.

0 C.--

TABLE 4.3-2 (Continued)

-_4 m

X>

ENGINEERED SAFETY FEATURES ACTUATION SYSTEM INSTRUMENTATION C n SURVEILLANCE REQUIREMENTS C-z TABLE NOTATION N)

(1) Each train shall be tested at the frequency specified in the Surveillance Frequency Control Program.

(2) Deleted (3) Deleted (4) Deleted (5) Deleted (6) Each actuation train shall be tested at a frequency in accordance with the Surveillance Frequency Control Program. Testing of each co actuation train shall include master relay testing of both logic trains. If an ESFAS instrumentation channel is inoperable due to failure of the Actuation Logic Test and/or Master Relay Test, increase-the surveillance frequency such that each train is tested at the frequency specified in the Surveillance Frequency Control Program unless the failure can be determined by performance of an engineering C (

evaluation to be a single random failure.

(7) For channels with bypass test instrumentation, input relays are tested at a frequency in accordance with the Surveillance Frequency Control Program.

3 3 (8) The test interval is R for Potter & Brumfield MDR Series slave relays.

1. O (9) Frequencies are specified in the Surveillance Frequency Control Program unless otherwise noted in the table.

3 D (D CD z z o

P "3)

3/4.5 EMERGENCY CORE COOLING SYSTEMS 3/4.5.1 ACCUMULATORS LIMITING CONDITION FOR OPERATION 3.5.1 Each Safety Injection System accumulator shall be OPERABLE APPLICABILITY:

MODES 1 and 2 MODE 3 with pressurizer pressure > 1000 psig ACTION:

a.

With one accumulator inoperable, except as a result of boron concentration outside the required limits, within 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> restore the inoperable accumulator to OPERABLE status or apply the requirements of the CRMP, or be in at least HOT STANDBY within the next 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br /> and reduce pressurizer pressure to less than 1000 psig within the following 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br />.

b.

With more than one accumulator inoperable, except as a result boron concentration outside the required limits, within 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> restore at least two accumulators to OPERABLE status or apply the requirements of the CRMP, or be in at least HOT STANDBY within the next 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br /> and reduce pressurizer pressure to less than 1000 psig within the following 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br />.

c.

With theboron concentration of one accumulator outside the required limit, within 72 hours8.333333e-4 days <br />0.02 hours <br />1.190476e-4 weeks <br />2.7396e-5 months <br /> restore the boron concentration to within the required limits or apply the requirements of the CRMP, or be in at least HOT STANDBY within the next 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br /> and reduce pressurizer pressure to less than 1000 psig within the following 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br />.

d.

With the boron concentrations of more than one accumulator outside the required limit, within 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> restore the boron concentration of at least two accumulators to within the required limits or apply the requirements of the CRMP, or be in at least HOT STANDBY within the next 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br /> and reduce pressurizer pressure to less than 1000 psig within the following 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br />.

SURVEILLANCE REQUIREMENTS 4.5.1.1 Each accumulator shall be demonstrated OPERABLE:

a.

At a frequency in accordance with the Surveillance Frequency Control Program by:

1)

Verifying the contained borated water volume is > 8800 gallons and < 9100 gallons and nitrogen cover-pressure is > 590 psig and 5 670 psig, and

2)

Verifying that each accumulator isolation valve is open.

b.

At a frequency in accordance with the Surveillance Frequency Control Program and within 6 hour6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br />s* after each solution volume increase of greater than or equal to 1% of tank volume that is not the result of addition from the RWST by verifying the boron concentration of the accumulator solution is > 2700 ppm and 5 3000 ppm, and

c.

At a frequency in accordance with the Surveillance Frequency Control Program when the RCS pressure is above 1000 psig by verifying that power to the isolation valve operator is removed.

  • The 6 hr. SR is only required to be performed for affected accumulators.

SOUTH TEXAS - UNITS 1 & 2 3/4 5-1 Unit 1 Amendment No. 5,,54,59,135 4 188 Unit 2 Amendment No. 40.43.47,124 1-66 175

EMERGENCY CORE COOLING SYSTEMS SURVEILLANCE REQUIREMENTS 4.5.2 Each ECCS subsystem shall be demonstrated OPERABLE:

a.

At a frequency in accordance with the Surveillance Frequency Control Program by verifying that the following valves are in the indicated positions with power to the valve operators removed:

Valve Number Valve Function Valve Position XS10008 A, B, C XRH0019 A, B, C High Head Hot Leg Recirculation Isolation Low Head Hot Leg Recirculation Isolation Closed Closed

b.

At a frequency in accordance with the Surveillance Frequency Control Program by:

1)

Verifying that the ECCS piping is full of water by venting the ECCS pump casings and accessible discharge piping high points, and

2)

Verifying that each valve (manual, power-operated, or automatic) in the flow path that is not locked, sealed, or otherwise secured in position, is in its correct position.

c.

By a visual inspection which verifies that no loose debris (rags, trash, clothing, etc.) is present in the containment which could be transported to the containment sump and cause restriction. of the pump suctions during LOCA conditions. This visual inspection shall be performed:

1)

For all accessible areas of the containment prior to establishing CONTAINMENT INTEGRITY, and

2)

Of the areas affected within containment at the completion of each containment entry when CONTAINMENT INTEGRITY is established.

d.

At a frequency in accordance with the Surveillance Frequency Control Program by avisual inspection of the containment sump and verifying that the subsystem suction inlets are not restricted by debris and that the sump components show no evidence of structural distress or abnormal corrosion.

SOUTH TEXAS - UNITS 1 & 2 3/4 5-4 Unit 1 - Amendment No. 1-83 188 Unit 2 - Amendment No. 4-7-0 175

ELECTRICAL POWER SYSTEMS LIMITING CONDITION FOR OPERATION (continued)

Suspend all operations involving CORE ALTERATIONS, operations involving positive reactivity additions that could result in loss of required SHUTDOWN MARGIN or required boron concentration, AND Initiate corrective action to restore the required DC electrical power subsystems to OPERABLE status as soon as possible.

SURVEILLANCE REQUIREMENTS 4.8.2.2 Each 125-volt battery bank shall be demonstrated OPERABLE:

-a.

At a frequency in accordance with the Surveillance Frequency Control Program by verifying that the total battery terminal voltage is greater than or equal to the minimum

,established float voltage.

b.

At a frequency in accordance with the Surveillance Frequency Control Program by verifying that the battery charger can supply at least 300 amperes at greater than or equal to the minimum established float voltage for at least 8 hours9.259259e-5 days <br />0.00222 hours <br />1.322751e-5 weeks <br />3.044e-6 months <br />.

OR:

Verify each battery charger can recharge the battery to the fully charged state within 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br /> while supplying the largest combined demands of the various continuous steady-state loads following a battery discharge to the bounding design-basis event discharge state.

c.

NOTE:

1. The modified performance discharge test in SR 4.8.2.3.f may be performed in lieu of Surveillance Requirement 4.8.2.2.c.
2. Credit may be taken for unplanned events that satisfy this surveillance requirement.

At a frequency in accordance with the Surveillance Frequency Control Program by verifying that the battery capacity is adequate to supply and maintain in OPERABLE status all of the actual or simulated ESF loads for the design duty cycle when the battery is subjected to a battery service test.

SOUTH TEXAS - UNITS 1 & 2 3/4 8-13a Unit 1 - Amendment No. 180, 82, 184 188 Unit2 -Amendment No. 167, 160, 171 175