From:

Farideh Saba Sent:

Wednesday, December 03, 2008 4:58 PM To:

Murray, William R. (Bill)

Cc:

Marshall David

Subject:

Acceptance of Brunswick Units 1 and 2 RR ISI-04 for Review MD9948 and MD9949

Bill, The LIC-109 acceptance review is completed satisfactorily for the subject relief request, "Brunswick Units 1 and 2 Proposed Alternative for Reactor Vessel Skirt Support Examinations."

However, we may have RAIs.

Farideh Farideh E. Saba, P.E.

Senior Project Manager NRC/ADRO/NRR/DORL 301-415-1447 Mail Stop O-8G9A Farideh.Saba@NRC.GOV E-mail Properties Mail Envelope Properties ()

Subject:

Acceptance of Brunswick Units 1 and 2 RR ISI-04 for Review MD9948 and MD9949 Sent Date: 12/3/2008 4:49:45 PM Received Date: 12/3/2008 4:57:00 PM From: Farideh Saba Created By: Farideh.Saba@nrc.gov Recipients:

Bill.Murray2@pgnmail.com (Murray, William R. (Bill))

Tracking Status: None Marshall.David@nrc.gov (Marshall David)

Tracking Status: None Post Office:

Files Size Date & Time MESSAGE 8009 12/3/2008

Options Expiration Date:

Priority: olImportanceNormal ReplyRequested: False Return Notification: False Sensitivity: olNormal Recipients received: