Request for Relief No. 13R-04 for the Third 10-Year Inservice Inspection Interval Regarding System Pressure Testing of Class 1 Systems (Tac MD8744)
ML083260136
Person / Time
Site: Harris 
Issue date: 01/21/2009
From: Boyce T
Plant Licensing Branch II
To: Burton C
Carolina Power & Light Co
Vaaler, Marlayna, NRR/DORL 415-3178
References
TAC MD8744
Download: ML083260136 (12)


Text

UNITED STATES NUCLEAR REGULATORY COMMISSION WASHINGTON, D.C. 20555-0001 January 21,2009 Chris L. Burton, Vice President Shearon Harris Nuclear Power Plant Carolina Power & Light Company Post Office Box 165, Mail Zone 1 New Hill, North Carolina 27562-0165

SUBJECT:

SHEARON HARRIS NUCLEAR POWER PLANT, UNIT 1 - RELIEF REQUEST 13R-04 FOR THE THIRD 10-YEAR INSERVICE INSPECTION INTERVAL REGARDING SYSTEM PRESSURE TESTING OF CLASS 1 SYSTEMS (TAC NO. MD8744)

Dear Mr. Burton:

By letter dated April 29, 2008, Carolina Power and Light Company (the licensee), now doing business as Progress Energy Carolinas, Inc., submitted Relief Request (RR) 13R-04, pertaining to the American Society of Mechanical Engineers Boiler and Pressure Vessel Code (ASME Code) requirements on system pressure testing of Class 1 systems for the third 10-year inservice inspection (lSI) interval at the Shearon Harris Nuclear Power Plant, Unit 1.

The requested relief pertains to the boundary subject to test pressurization during performance of a system leakage test conducted at or near the end of an inspection interval. In lieu of the ASME Code requirement that the test extend to all Class 1 pressure retaining components within the system boundary, the licensee proposed an alternative to pressurize only up to the inboard isolation valves of several systems that would exclude a small segment of the Class 1 pressure boundary from attaining test pressure. However, a visual examination during pressurization would include all components within the system boundary.

Based on the information provided in RR 13R-04, the U.S. Nuclear Regulatory Commission (NRC) staff concluded that compliance with the ASME Code requirement would result in hardship or unusual difficulty without a compensating increase in the level of quality and safety.

In addition, the NRC staff finds that the licensee's proposed alternative continues to provide reasonable assurance of structural integrity and is, therefore, acceptable.

Therefore, pursuant to Title 10 of the Code of Federal Regulations, Part 50.55a(a)(3)(ii), the NRC authorizes the lSI program alternatives proposed in RR 13R-04 for the third 10-year lSI interval at the Shearon Harris Nuclear Power Plant, Unit 1.

C. Burton

- 2 The NRC staff's safety evaluation is enclosed. If you have any questions regarding this matter, please contact Marlayna Vaaler at (301) 415-3178.

Sincerely,

~

Thomas H. Boyc,Chief Plant Licensing ranch 11-2 Division of Operating Reactor Licensing Office of Nuclear Reactor Regulation Docket No. 50-400

Enclosure:

Safety Evaluation cc w/enclosure: Distribution via ListServ

UNITED STATES NUCLEAR REGULATORY COMMISSION WASHINGTON, D.C. 20555-0001 SAFETY EVALUATION BY THE OFFICE OF NUCLEAR REACTOR REGULATION THIRD 10-YEAR INTERVAL INSERVICE INSPECTION PROGRAM RELIEF REQUEST 13R-04 REGARDING SYSTEM PRESSURE TEST OF CLASS 1 SYSTEMS SHEARON HARRIS NUCLEAR POWER PLANT, UNIT 1 CAROLINA POWER & LIGHT COMPANY DOCKET NO. 50-400

1.0 INTRODUCTION

By letter dated April 29, 2008, Carolina Power and Light Company (the licensee), now doing business as Progress Energy Carolinas, Inc., submitted Relief Request (RR) 13R-04, pertaining to the American Society of Mechanical Engineers Boiler and Pressure Vessel Code (ASME Code),Section XI requirements on system pressure testing of Class 1 systems for the third 10 year inservice inspection (lSI) interval at the Shearon Harris Nuclear Power Plant, Unit 1 (HNP).

The requested relief pertains to the boundary subject to test pressurization during performance of a system leakage test, conducted at or near the end of inspection interval, in accordance with the ASME Code,Section XI, for the Class 1 portions of the safety injection (SI) system, pressurizer spray, residual heat removal (RHR) system, and various specified drains, vent, test and fill lines in the reactor coolant system (RCS). The attached Table 1 identifies the specific Class 1 pressure retaining components that are associated with the requested relief.

In lieu of the ASME Code requirement that the test extend to all Class 1 pressure retaining components within the system boundary, the licensee proposed an alternative to pressurize only up to the inboard isolation valves of the affected systems, which would exclude a small segment of the Class 1 pressure boundary from attaining the ASME Code-required test pressure. However, a visual examination during pressurization would include all components within the system boundary.

The U.S. Nuclear Regulatory Commission (NRC) staff evaluated the licensee's request for relief and the proposed alternative pursuant to Title 10 of the Code of Federal Regulations (10 CFR)

Part 50.55a(a)(3)(ii), in order to determine that compliance with the ASME Code requirement would result in hardship without a compensating increase in the level of quality and safety.

2.0 REGULATORY REQUIREMENTS The requirements of 10 CFR 50.55a(g) specify that inservice inspection of ASME Code Class 1, 2, and 3 components be performed in accordance with Section XI of the ASME Code and applicable addenda, except where specific written relief has been granted by the Commission pursuant to 10 CFR 50.55a(g)(6)(i). According to 10 CFR 50.55a(a)(3), alternatives to the requirements of parqgraph 50.55a(g) may be used, when authorized by the Director of the Enclosure

- 2 Office of Nuclear Reactor Regulation (NRR), if an applicant demonstrates that: (i) the proposed alternatives would provide an acceptable level of quality and safety, or (ii) the specified requirement would result in hardship or unusual difficulty without a compensating increase in the level of quality and safety.

Pursuant to 10 CFR 50.55a(g)(4)(i), ASME Code Class 1,2, and 3 components (including supports) shall meet the requirements, except the design and access provisions and the preservice examination requirements, set forth in the ASME Code,Section XI, "Rules for Inservice Inspection of Nuclear Power Plant Components," to the extent practical within the limitations of design, geometry, and materials of construction of the components.

The regulations require that lSI of components and system pressure tests conducted during the first 1O-year interval and subsequent intervals comply with the requirements in the latest edition and addenda of Section XI of the ASIV1E Code incorporated by reference in 10 CFR 50.55a 12 months prior to the start of the 120-month interval, subject to the limitations and modifications listed in paragraph (b) of the section. The lSI Code of Record for the third 10-year inservice inspection interval at HNP is the 2001 Edition through the 2003 Addenda of the ASME Code,Section XI.

3.0 TECHNICAL EVALUATION

3.1 System/Component(s) for Which Relief is Requested All ASME Code Class 1 components within the system pressure boundary between isolation valves as identified in Table 1 of this safety evaluation.

3.2 ASME Code Requirements Table IWB-2500-1, Examination Category B-P, Item Number B15.10, requires that all Class 1 pressure retaining components be subject to a system leakage test with a VT-2 visual examination in accordance with IWB-5220. This pressure test is to be conducted prior to plant startup following each reactor refueling outage. The pressure retaining boundary for the test to be conducted at or near the end of each inspection interval shall be extended to all Class 1 pressure retaining components per IWB-5222(b).

3.3 Licensee's Request for Relief The requested relief pertains to the boundary subject to test pressurization during performance of a system leakage test, conducted at or near the end of inspection interval, in accordance with the ASME Code,Section XI, for the Class 1 portions of the SI system, pressurizer spray, RHR system, and various specified drains, vent, test and fill lines in the RCS.

In lieu of the ASME Code requirement that the test extend to all Class 1 pressure retaining components within the system boundary, the licensee proposed that a system leakage test be conducted at or near the end of each inspection interval, prior to reactor startup. The segment of Class 1 piping between an inboard and an outboard isolation valve, including the valves in the system boundary for the RHR system, SI system, and RCS, will be visually examined for evidence of past leakage and/or leakage during the system leakage test conducted with the isolation valves in the position required for normal reactor startup.

- 3 3.4 Licensee's Basis for Requesting Relief Normal reactor coolant pressure at 100 percent rated power for HNP is approximately 2235 pounds per square inch gauge (psig). The components and piping connected to the RCS, the SI system, and the RHR system, such as vents, drains, and instrument connections, for which relief is requested, are the portions of piping between an inboard and an outboard isolation valve, and include the valves themselves.

These segments of piping will not be pressurized to the ASME Code-required test pressure of 2235 psig during the system leakage test. The licensee stated that compliance with the requirements of the ASME Code by pressurizing to RCS pressure beyond the inboard isolation valve during performance of a system leakage test would result in hardship without a compensating increase in the level of quality and safety due to the following: 1) the special valve lineup required for the test adds unnecessary challenge to the system configuration; and

2) there are no test connections between the isolation valves. Consequently, a system pressure test conducted per the ASME Code requirements would require opening the first manual isolation valve to test the segment of piping up to the second isolation valve, thereby defeating the double isolation and reducing the margin of personnel safety for those performing the test.

The following specific lines are included in the request for relief:

1.

Small Size Class 1 Vent, Drain, Test, and Fill Lines

2.

Piping segments consisting of two 86 foot runs of 12 inch diameter piping between RHR inlet valves 1RH-39 and 40, and 1RH-1 and 2

3.

Piping segments in the SI Loops Low Head Check Valves 1SI-250, 1SI-252, and 1SI-254, and upstream piping in each segment up to the second isolation valve

4.

Piping segments in the SI Loops High Head Check Valves 1SI-81, 1SI-82, 1SI-83, 1SI-136, 1SI-137, and 1SI-138, and upstream piping in each segment up to the second isolation valve In pressurizing the above piping segments, including the isolation valves, to the ASME Code-required test pressure, the licensee would be subject to hardship or unusual difficulty without a compensating increase in the level of quality and safety as stated below.

The affected components are located inside containment. Tests performed inside the radiologically restricted area increase the total exposure to plant personnel while modifying and restoring system lineups, as well as increase the contamination of test equipment.

Use of single valve isolation from systems with lower design pressures could result in over-pressurization of these lower pressure systems and cause damage to permanent plant equipment.

Use of single valve isolation is a significant personnel safety hazard.

There are no test connections for pressurizing the piping between the check valves in the RHR and the SI system, and thus, pressurization using an external source would require significant modification to the piping segments.

- 4 3.5 Licensee's Proposed Alternative The Class 1 system pressure boundary during the end of interval system leakage test will be maintained in a normal, operational alignment with the items identified in Table 1 constituting exceptions to the ASME Code-required test boundary. However, the VT-2 visual examination will extend to all components within the Class 1 pressure boundary. Items listed in Table 1 will be visually examined for evidence of leakage during the system leakage testing without being pressurized to the ASME Code-required test pressure.

4.0 STAFF EVALUATION The 2001 Edition through the 2003 Addenda to the ASME Code,Section XI, Table IWB-2500-1, Category B-P, Item B15.51, requires performance of a system leakage test for the Class 1 pressure retaining piping once per 1O-year interval, to be conducted at or near the end of each inspection interval, prior to reactor startup. The system leakage test is required to be performed at a test pressure not less than the nominal operating pressure of the RCS corresponding to 100 percent rated reactor power and shall include all Class 1 components within the RCS boundary. However, in RR 13R-04, the licensee proposed an alternative to the boundary subject to test pressurization as required under the ASME Code,Section XI, for the RCS drains, vent, test and fill lines, and the piping segments of the Sl and RHR systems between an inboard and an outboard isolation valve in the system boundary.

The piping configuration, as outlined, provides for double-isolation of the RCS. Under normal plant operating conditions, the subject pipe segments would see RCS temperature and pressure conditions only if leakage through the inboard isolation valve occurs. With the inboard isolation valve closed during the system leakqge test as requested in RR 13R-04, the segment of piping between the inboard and outboard isolation valve would not be pressurized to the ASME Code-required test pressure during the system leakage test. To perform the ASME Code-required test, it would be necessary to manually open each inboard isolation valve in order to pressurize the corresponding pipe segment. Pressurization by this method would preclude double valve isolation of the RCS and may cause a safety concern for the personnel performing the examination. Alternatively, the line segments between the isolation valves could be separately pressurized to the required test pressure by a hydrostatic pump, but there are no test connections between the isolation valves to attach such a pump. In addition, the subject isolation valves are located inside containment, and any manual actuation (opening and closing) of these valves would subject plant personnel to undue radiation exposure during modification, examination, and restoration of system lineups.

The licensee proposed an alternative to conduct a visual leak examination (VT-2) of the isolated portions of the subject piping segments with the inboard and outboard isolation valves in the normally closed position. This visual examination would indicate any evidence of past leakage during the operating cycle, as well as any active leakage during the system leakage test if the inboard isolation valve leaks. The staff believes that the licensee's proposed alternative will continue to provide reasonable assurance of the structural integrity of the RCS drains, vent, test and fill lines, and the piping segments in the Sl and RHR systems between the inboard and outboard isolation valves, including the isolation valves themselves, while maintaining personnel radiation exposure to as low as reasonably achievable.

- 5 Based on the considerations of personnel safety and radiation exposure, the NRC staff concurs with the licensee's finding that compliance with the ASME Code requirement for conducting a system leakage test would result in hardship for the facility. Furthermore, a compensating increase in the level of quality and safety would not be provided by performing the test in accordance with the ASME requirements as the alternative proposed by the licensee continues to fuHili the basis for conducting the system leakage test without endangering plant personnel.

5.0 CONCLUSION

Based on the NRC staff's evaluation, test pressurization to the ASME Code-required level corresponding to full RCS pressure during a system leakage test of the Class 1 pressure retaining components within the system boundary of the RCS would result in hardship to the licensee without a compensating increase in the level of quality and safety. In addition, the licensee's proposed alternative continues to provide reasonable assurance of structural integrity for the subject piping segments. Therefore, pursuant to 10 CFR 50.55a(a)(3)(ii), the proposed alternative in RR 13R-04 is authorized for the third 1O-year lSI interval at the Shearon Harris Nuclear Power Plant, Unit 1. The relief granted is authorized by law and will not endanger life or property or the common defense and security, and is otherwise in the public interest given due consideration to the burden upon the licensee that could result if the requirements were imposed on the facility. All other requirements of the ASME Code,Section XI, for which relief has not been specifically requested remain applicable, including third party review by the Authorized Nuclear Inservice Inspector.

Principal Contributor: Prakash Patnaik Date: January 21, 2009

RELIEF REQUEST 13R-04 TABLE 1 AFFECTED CLASS 1 PRESSURE RETAINING COMPONENTS EXAMINATION CATEGORY B-P Affected Line or Component Pipe Diameter (in.)

Approx.

Length Boundary Exception(s)

Loop Drain Line Isolation Valve 2

s; 1 ft.

Valve 1RC-7 remains closed to avoid pressurizing downstream Class 1 pipe and valve 1RC-8 Loop Drain Line Isolation Valve 2

s; 1 ft.

Valve 1RC-16 remains closed to avoid pressurizing downstream Class 1 pipe and valve 1RC-17 Loop Drain Line Isolation Valve 2

s; 1 ft.

Valve 1RC-28 remains closed to avoid pressurizing downstream Class 1 pipe and valve 1RC-29 Pressurizer PORV Vent Line on Primary Sample Path off Pressurizer 0.75 0.5 ft.

Valve 1RC-11 0 remains closed to avoid pressurizing downstream Class 1 pipe and valve 1RC-111 Instrument Vent Line on Pressurizer Level Instrument Loop 1LT-459 0.5 0.5 ft.

Valve 1RC-984 remains closed to avoid pressurizing downstream Class 1 pipe and valve 1RC-985 Instrument Vent Line on Pressurizer Level Instrument Loop 1LT-460 0.5 0.5 ft.

Valve 1RC-986 remains closed to avoid pressurizing downstream Class 1 pipe and valve 1RC-987 Instrument Vent Line on Pressurizer Level Instrument Loop 1LT-461 0.5 0.5 ft.

Valve 1RC-988 remains closed to avoid pressurizing downstream Class 1 pipe and valve 1RC-989 CVCS Pressurizer Spray Downstream Check Valve and 2

s; 1 ft.

Check valve to remain closed to avoid disassembly or other temporary configurations required to achieve test pressures at upstream piping and valves 1CS-491 and 1CS-488 Test Connection Isolation Valve 1

1.5 ft.

Valve 1CS-489 remains closed to avoid pressurizing downstream Class 1 pipe and valve 1CS-490 Attachment

- 2 Affected Line or Component Pipe Diameter (in.)

Approx.

Length Boundary Exception(s)

Norm Charging Line Upstream Check Valve and 3

s; 1 ft.

Check valve to remain closed to avoid disassembly or other temporary configurations required to achieve test pressures at upstream piping and valves 1C8-500 and 1C8-497 Test Connection Isolation Valve 1

1.5 ft.

Valve 1C8-498 remains closed to avoid pressurizing downstream Class 1 pipe and valve 1C8-499 Alt Charging Line Upstream Check Valve and Test 3

s; 1 ft.

Check valve to remain closed to avoid disassembly or other temporary configurations required to achieve test pressures at upstream piping and valves 1C8-486 and 1C8-483 Connection Isolation Valve 1

1.5 ft.

Valve 1C8-484 remains closed to avoid pressurizing downstream Class 1 pipe and valve 1C8-485 Excess Letdown Upstream Isolation Valve 1

1.5 ft.

Valve 1C8-460 remains closed to avoid pressurizing downstream Class 1 pipe and valve 1C8-461 Between Accumulator 1A-8A Discharge Check Valve and 81 to RC8 Loop "A" Check Valve 12 26 Check valve to remain closed to avoid disassembly or other temporary configurations required to achieve test pressures at upstream piping and valves 181-249 and 181-250 1

2 Valve 181-273 remains closed to avoid pressurizing downstream Class 1 pipe and valve 181-274 Between Accumulator 1B-8B Discharge Check Valve and 81 to RC8 Loop "B" Check Valve 12 28 Check valve to remain closed to avoid disassembly or other temporary configurations required to achieve test pressures at upstream piping and valves 181-251 and 181-252 1

2 Valve 181-275 remains closed to avoid pressurizing downstream Class 1 pipe and valve 181-276 Between Accumulator 1C-8A Discharge Check Valve and 81 to RC8 Loop "C" Check Valve 12 26 Check valve to remain closed to avoid disassembly or other temporary configurations required to achieve test pressures at upstream piping and valves 181-253 and 181-254 1

2 Valve 181-277 remains closed to avoid pressurizing downstream Class 1 pipe and valve 181-278 RC8 Loop to RHR Pump "B" 12 86 Valves 1RH-39 and 1RH-40 remain closed to avoid over-pressurization of the RHR system Isolation and Drain Line 1

2 Valve 181-41 remains closed to avoid pressurizing downstream Class 1 pipe and valve 181-42

- 3 Affected Line or Component Pipe Diameter (in.)

Approx.

Length Boundary Exception(s)

RC8 Loop to RHR Pump "A" 12 86 Valves 1RH-1 and 1RH-2 remain closed to avoid over-pressurization of the RHR system Isolation and Drain Line 1

2 Valve 1RH-3 remains closed to avoid pressurizing downstream Class 1 pipe and valve 1RH-4 6

38 Check valve to remain closed to avoid disassembly or other temporary configurations required to achieve test pressures at upstream pipinQ and valves 181-81,181356,181-8, and 181-7 2

68 RC8 Cold Leg Loop 1 818, 2

3 Boron injection, and CVC8 paths.

1 1.5 Valve 181-27 remains closed to avoid pressurizing downstream Class 1 pipe and valve 181-28 1

1.5 Valve 181-79 remains closed to avoid pressurizing downstream Class 1 pipe and valve 181-80 6

33 Check valve to remain closed to avoid disassembly or other temporary configurations required to achieve test pressures at upstream piping and valves 181-82, 181357, 181-9, and 181-73 2

83 Class 1 piping from Residual Heat Exchanger 2

7 to RC8 Cold Leg Loop 2.

1 1.5 Valve 181-33 remains closed to avoid pressurizing downstream Class 1 pipe and valve 181-34 1

1.5 Valve 181-75 remains closed to avoid pressurizing downstream Class 1 pipe and valve 181-76 6

25.5 Check valve to remain closed to avoid disassembly or other temporary configurations required to achieve test pressures at upstream piping and valves 181-83, 181358, 181-10, and 181-74 2

49.5 Class 1 piping from Residual Heat Exchanger 2

1.5 to RC8 Cold Leg Loop 3.

1 1.5 Valve 181-39 remains closed to avoid pressurizing downstream Class 1 pipe and valve 181-40 1

1.5 Valve 181-77 remains closed to avoid pressurizing downstream Class 1 pipe and valve 181-78 6

43 Check valve to remain closed to avoid disassembly or other temporary configurations required to achieve test pressures at upstream piping and valves 181-136, 181-134, 181-104, and 181-127 Class 1 piping from Residual Heat Exchanger to RC8 Hot Leg Loop 1.

2 2.5 2

2.5 1

1.5 Valve 181-376 remains closed to avoid pressurizing downstream Class 1 pipe and valve 181-377

- 4 Affected Line or Component Pipe Diameter (in.)

Approx.

Length Boundary Exception(s) 6 44.5 Check valve to remain closed to avoid disassembly or other temporary configurations required to achieve test pressures at upstream piping and valves 181-137,181-135,181-105, and 181-128 Class 1 piping from Residual Heat Exchanger to RC8 Hot Leg Loop 2.

2 2.5 2

2.5 1

1.5 Valve 181-132 remains closed to avoid pressurizing downstream Class 1 pipe and valve 181-133 6

1 Check valve to remain closed to avoid disassembly or other temporary configurations required to achieve test pressures at upstream piping and valves 181-138, 181-106, and 181-129 Class 1 piping 2

42.5 from Residual 2

1 Heat Exchanger 2

1 to RC8 Hot Leg Loop 3.

1 1.5 Valve 181-130 remains closed to avoid pressurizing downstream Class 1 pipe and valve 181-131

C. Burton

- 2 The NRC staff's safety evaluation is enclosed. If you have any questions regarding this matter, please contact Marlayna Vaaler at (301) 415-3178.

Sincerely, IRA!

Thomas H. Boyce, Chief Plant Licensing Branch 11-2 Division of Operating Reactor Licensing Office of Nuclear Reactor Regulation Docket No. 50-400

Enclosure:

Safety Evaluation cc w/enclosure: Distribution via ListServ DISTRIBUTION:

PUBLIC LPL2-2 R/F RidsNrrPMMVaaler RidsNrrLACSola RidsNrrDorlLpl2-2 RidsOgcRp RidsAcrsAcnw_MailCTR PPatnaik, NRR RidsRgn2MailCenter (RMusser)

RidsNrrDciCsgb ADAMS Accession Number: ML083260136 NRR-028 OFFICE LPL2-2/PM LPL2-2/LA CSGB/BC OGC NLO LPL2-2/BC NAME MVaaler CSoia AHiser*

LStubin TBoyce DATE 12/12/08 11/28/08 12/08/08 01/06/09 01/21/09

  • by memo OFFICIAL RECORD COpy