MONTHYEARML0810102072008-04-0303 April 2008 Diablo Canon, Units 1 & 2 - License Amendment Request 08-02, Revision to Technical Specification 3.7.5, Auxiliary Feedwater System and 3.7.6 Condensate Storage Tank and Fire Water Storage Tank Project stage: Request ML0815405402008-06-0404 June 2008 Amendments Auxiliary Feedwater and Condensate Storage Tanks (TACs MD8471 and MD8472) Project stage: Other DCL-08-023, Supplement to License Amendment Request 08-02, Revision to Technical Specifications 3.7.5, Auxiliary Feedwater System, and 3.7.6, Condensate Storage Tank and Fire Water Storage Tank2008-06-20020 June 2008 Supplement to License Amendment Request 08-02, Revision to Technical Specifications 3.7.5, Auxiliary Feedwater System, and 3.7.6, Condensate Storage Tank and Fire Water Storage Tank Project stage: Supplement ML0825404362008-07-24024 July 2008 Email Sending Request for Additional Information, Revise TS 3.7.5, Auxiliary Feedwater System and 3.7.6, Condensate Storage Tank and Fire Water Storage Tank Project stage: RAI ML0825404962008-07-24024 July 2008 Draft Diablo Canyon, Units 1 and 2, Request for Additional Information, Revise TS 3.7.5, Auxiliary Feedwater System and 3.7.6, Condensate Storage Tank and Fire Water Storage Tank Project stage: Draft RAI ML0820407482008-08-0101 August 2008 Acceptance Review of Proposed Amendments Revision to Technical Specifications 3.7.5, Auxiliary Feedwater System, & 3.7.6, Condensate Storage Tank & Fire Water Storage Tank (Tac Nos. MD8471 and MD8472) Project stage: Acceptance Review ML0828314432008-09-21021 September 2008 CST RAIs (Email) Project stage: RAI ML0826702672008-09-21021 September 2008 Request for Additional Information on Condensate Storage Tank Level Amendment Project stage: RAI DCL-08-081, Response to Request for Additional Information, License Amendment Request 08-02, Revision to Technical Specifications 3.7.5, Auxiliary Feedwater System, and 3.7.6, Condensate Storage Tank and Fire Water Storage Tank2008-10-0101 October 2008 Response to Request for Additional Information, License Amendment Request 08-02, Revision to Technical Specifications 3.7.5, Auxiliary Feedwater System, and 3.7.6, Condensate Storage Tank and Fire Water Storage Tank Project stage: Response to RAI ML0906904322008-11-0404 November 2008 Unit Nos.1 and 2 - Email Request for Additional Information Re License Amendment Request Project stage: RAI DCL-08-093, Response to NRC Request for Additional Information Regarding License Amendment Request 08-02, Revision to Technical Specifications 3.7.5, Auxiliary Feedwater System, and 3.7.6, Condensate Storage Tank and Fire Water2008-11-0606 November 2008 Response to NRC Request for Additional Information Regarding License Amendment Request 08-02, Revision to Technical Specifications 3.7.5, Auxiliary Feedwater System, and 3.7.6, Condensate Storage Tank and Fire Water Project stage: Response to RAI ML0906902942008-11-21021 November 2008 Meeting Slide, Spectra 6.5 Slide from Pacific Gas and Electric Regarding License Amendment Request Re AFW System and CST, Diablo Canyon Power Plant, Unit Nos. 1 and 2 Project stage: Meeting ML0906902422008-11-21021 November 2008 Email from Pacific Gas and Electric Regarding Spectra 6.5 Slide, License Amendment Request Re AFW System and CST Project stage: Request DCL-08-106, Response to NRC RAI Regarding License Amendment Request 08-02, Revision to Technical Specifications 3.7.5, Auxiliary Feedwater System, and 3.7.6, Condensate Storage Tank and Fire Water Storage Tank2008-12-16016 December 2008 Response to NRC RAI Regarding License Amendment Request 08-02, Revision to Technical Specifications 3.7.5, Auxiliary Feedwater System, and 3.7.6, Condensate Storage Tank and Fire Water Storage Tank Project stage: Response to RAI ML0906308082009-03-30030 March 2009 Issuance of Amendment Nos. 204 and 205, Revise TS 3.7.5, Auxiliary Feedwater (AFW) System, and TS 3.7.6, Condensate Storage Tank (CST) and Fire Water Storage Tank (Fwst) Project stage: Approval 2008-04-03
[Table View] |
Text
From:
Alan Wang Sent:
Sunday, September 21, 2008 8:31 PM To:
'Ken Schrader'
Subject:
CST RAIs Ken, here are 3 questions from Gardocki. Let me know if you want a call before I issue. Alan SBPB RAI 1 On page 4 of the license amendment request, the condensate storage tank (CST) is described as having a floating roof to minimize oxygen absorption by the stored water. This implies that the roof of the tank would follow the water level as it decreases. However, the plenums extend into the inner volume of the tank and might block the path of the floating roof if water level drops below the tops of the plenums.
In accordance with 10 CFR 50.59, the licensee can make changes to the facility; however, that change should not create a possibility for a malfunction of an structure, system and component (SSC) important to safety with a different result than any previously evaluated.
Describe how the modifications to the CST impact the function of the floating roof, and verify that no new failure mechanisms are created that affect the ability of the CST to provide its safety related function.
SBPB RAI 2 to the license amendment supplemental information (Westinghouse Letter PGE 45) states that the assumed level restoration was reduced from no load programmed level to the Narrow Range lower level tap, in order to reduce the required CST inventory.
10 CFR 50.34 requires the licensee comply with the Standard Review Plan, NUREG 0800, or provide an acceptable alternative. NUREG 0800, Section 13.5.2.1, Operating and Emergency Operating Procedures, states that the Emergency Operating Procedures (EOPs) will be based upon acceptable technical guidelines derived from approved analyses of transients and accidents.
Describe how this change in the restoration level is reflected in the plant operating procedures for loss-of-offsite-power with a natural circulation cooldown.
Verify that any difference in restoration level assumed in the calculation and the plant operating procedures will not have adverse effects on the ability to prevent forming voids in the reactor vessel while cooling the RCS.
SBPB RAI 3 The license amendment request would fully remove the fire water storage tank (FWST) requirements from the Technical Specifications (TS). Afterwards, the licensee intends to remove the FWST from service for approximately 90 days.
In accordance with 10 CFR 50.36 (d)(2)(ii), the licensee is required to provide a TS limiting condition for operation (LCO) for meeting any of four specific criterion.
Confirm that there is no credit for the FWST that would necessitate FWST inclusion in TS, including any license conditions, commitments, or credit in design basis.
E-mail Properties Mail Envelope Properties (419623E8C7444444BF132DA3AE69EDA2105EA954F7)
Subject:
CST RAIs Sent Date: 9/21/2008 8:31:14 PM Received Date: 9/21/2008 8:31:00 PM From: Alan Wang Created By: Alan.Wang@nrc.gov Recipients:
KJSe@pge.com ('Ken Schrader')
Tracking Status: None Post Office:
HQCLSTR02.nrc.gov Files Size Date & Time MESSAGE 7993 9/21/2008 Options Expiration Date:
Priority: olImportanceNormal ReplyRequested: False Return Notification: False Sensitivity: olNormal Recipients received: