Rancho Seco Final Status Survey Summary Report May 14, 2008 Folsom Intake, Helo Pad, South Scrap Yard Combined Survey Survey Unit F8000011 Prepared By..GA

-VL)KP(

Date:-

Sieer Reviewed By: __

Date: 5.27 O, "LeaaFSS Engineer Approved By:

Date:

739 C

Dismantlement Superintendent, Radiological

FINAL STATUS SURVEY

SUMMARY

REPORT Survey Unit:

F800001 1, Folsom Intake, Helo Pad, South Scrap Yard Combined Survey Survey Unit

Description:

Operating History: The E-W corridor in the Industrial Area was located to the north of the rail spur between the cooling towers and the power block. Included in this survey.

unit were all the concrete and asphalt roads, the concrete berm beside the road, the raised area next to the cooling tower pipe cradle structure, and the asphatlt/concrete pads remaining from the demolition of the Contractor Fab Shop (identified as 85:3000 in the HAS and is summarized below). Operating records and the HSA document several nearby leaks or spills with the potential for a release of radioactivity associated with this survey area. The HSA documented the storage of radioactive material within the area that may have had the potential to contaminate the area.

Site Characterization: The pavement was surveyed. Measurements taken on the asphalt and concrete surfaces showed a mean level of 3,664 dpm/l100 cm2 and a maximum of 7,175 dpm/100 cm2. Based on the classification procedure (DSIP-0020) and low levels of Cs-137 reported, the area was determined to be a Class 2 land area.

HSA Events: LER-7505, 8304, 8335.

Survey Unit Design Information:

The Survey Unit Design Parameters are presented in Table 1 below. The survey unit and measurement locations are depicted on the maps in Attachrmient 1. Direct measurement locations were randomly determined and 1131 m2 were scanned for approximately 7%

coverage. Soil samples were collected at each direct measurement location and analyzed by HPGe detector. The instrumentation used for the survey along with the MDC values are listed in Tables 2-1 and 2-2 in Attachment 2.

Page 2 of 7 FSS Summary Report F8000011.

Table 1. Survey Unit Design Parameters Survey Design Parameter I Value I

Comment Survey Area:

F800 Survey Unit:

Class:

SU Area (m2):

Evaluator:

DCGL Cs137 surrogate (pci/g):

Area 'Factor:

Design DCGLemc (pCi/g):.

LBGR (pCi/g):

Design Sigma (pCi/g):

Type I Error:

Type II Error:

Nuclide:

Sample Area (m2):

Total Area Scanned (m2):

Scan Coverage (%):

Z1-0 Sign P:

Calculated Relative Shift:

Relative Shift Used:

N-Value:

Design N-Value + 20%:

Grid Spacing L:

0011 3

17284 Gary Frank 52.6 N/A N/A 26.3 0.1 0.05 0.05 Cs137 N/A 1131 6.5%

1.645 1.645 0.99865 263 3

11 14 N/A Folsom Intake, Helo Pad, South Scrap Yard Combined Survey Open Land Area LTP Table 5-4 Class 3 Class 3 Default = 50% DCGL DTBD-06-001, Table 5-4D Class 3 Class 3 Uses 3.0 if Rel Shift >3 NUREG-1575 Table 5-5 Class 3 Page 3 of 7 FSS Summary Report F8000011

Survey Results:

A total of 14 direct measurements were made in F80000 11. The results including mean, median, standard deviation and range are shown in Table 2. All of the direct measurements were less than the DCGL. None of the scan measurements indicated areas of elevated activity. Soil samples were counted to the MDC shown in Table 2-1 of.

Table 2. Direct Measurement Results (all activity values in pCi/g)

Measurement ID Cs137 MDA Cs137 Activity Uncertainty Mean:

4,97E-0 I.

Median:

7.96E-0OI Standard Deviation:

3.94E-0 I________

Range:

4.56E-02 to 8.74E-01 F8000011A0001GD 8.16E-01

< 8.16E-01 F8000011A0002GD 8.01E-01

< 8.01E-01 F800001 1A0003GD 8.20E-01

< 8.20E-01 F8000011A0004GD 7.91E-01

< 7.91E-01 F8000011A0005GD 8.20E-01

< 8.20E-01 F800001 lA0006GD 8.70E-01

< 8.70E-01 F8000011A0007GD 8.03E-01

< 8.03E-01 F800001 1A0008GD 8.74E-01

< 8.74E-01 F8000011SOOO1SS 5.16E-02

< 5.16E-02 F8000011SO002SS 4.56E-02

< 4.56E-02 F8000011SO003SS 6.88E-02

< 6.88E-02 F8000011SO004SS 5.79E-02

< 5.79E-02 F8000011SO005SS 7.40E-02

< 7.40E-02 F8000011SO006SS 5.81E-02

< 5.81E-02 Page 4 of 7 FSS Summary Report F8000011

Survey Unit Data Assessment:

The survey design required 14 direct measurements for the Sign Test. The critical value and the results of the Sign Test are presented in Table 3. The sample mean and median values were less than the DCGL. The sample standard deviation was greater than the design standard deviation but both values of sigma resulted in a relative shift greater than three (3), no additional samples were required.

Page 5 of 7 FSS Summary Report F8000011

Table 3. Data Assessment Results Survey Results Parameter Value Comment Actual Direct Measurements (N):

14 Median (pCi/g):

7.96E-01 Mean (pCi/g):

4.97E-01 Standard Deviation (pCi/g);

3.94E-01 Maximum (pci/g):

8.74E-01 Sign Test Final N Value:

14 S+ Value:

14 Critical Value:

10 Sufficient Samples Collected:

Yes Maximum Value < DCGL:

Yes Median Value < DCGL:

Yes Mean Value < DCGL:

Yes Maximum Value < DCGLemc:

N/A Class 3 Standard Deviation <= Sigma:

Investigate Results <0.5 DCGL Pass the Sign Test?

Yes Reject the Null Hypothesis?

Yes The survey unit passes all conditions?

Investigate Survey unit passes Page 6 of 7 FSS Summary Report F8000011

Survey Unit Investigations and Results:

No investigations were required for either direct or scan measurements and no investigation results are reported.

ALARA Statement:

As stated in Chapter 4 of the LTP, as long as the residual activity within the survey unit is less than the DCGL, the ALARA criterion has been met.

Changes in Initial Survey Unit Assumptions:

The survey unit was designed as a Class 3 land survey and the sample results are consistent with that classification. The variability of the survey results was greater than the characterization data used for survey design. No potential areas of elevated activity were detected.

==

Conclusion:==

The FSS of this survey unit was properly designed as a Class 3 survey based on Table 5-4 of the LTP. The required number of direct measurements was made and the scan coverage met the requirement of Table 5-6 of the LTP. All of the direct measurements were less than the DCGL. No investigations were required.

The direct measurement data support rejection of the null hypothesis, providing high confidence that the survey unit satisfied the release criteria and that the data quality objectives were met.

It is concluded that survey unit F800001 1 meets the release criteria of 10CFR20.1402.

Page 7 of 7 FSS Summary Report F8000011

Attachment I Maps May 13, 2008 Survey Unit F8000011

CtD 0

(dn 00 C0 C)

0 00 C0 (D0D Instrumentation May 13, 2008 Survey Unit F8000011

Table 2-1. Survey Unit Instrumentation Detector Detector Serial Instrument Model MDC NoN

'No.

HPGe N/A 05069128 Soil - 0.0456 pCi/g Cs-137 Inspector N/A 08051294 Asphalt - 0.791 pCi/g Cs-137 Soil - 0.15 pCi/g Cs-137 ISOCS N/A 2983947 Soil - 0.136 pCi/g Co-60 I___

I I

Asphalt - 0.248 pCi/g Cs-137 Table 2-2. Investigation Criteria and DCGL Instrument Parameter Value Soil - 26.3 pCi/g Cs-137 ISOCS Investigation Criteria - Scan Soil - 6.3 pCi/g Co-60 Asphalt - 26.3 pCi/g Cs-137 All DCGLw 52.6 Cs-137 12.6 Co-60 Page 2 of 2 Att. 2 Instrumentation F8000011 Investigation May 13, 2008 Survey Unit F8000011 (none required)

Data Assessment May 13, 2008 Survey Unit F8000011

0 Ci)

Ci)

F8000011 Quantile Plot Cs137 DCGL = 52.6 pCi/g U

.5 0

1.200 1.000 0.800 0.600 0.400 0.200 0.000

-0.200

-0.400

-0.600 0.796 0

20 40 60 Percentile 80 100 I

  • Activty -

Median -

- - 75th Percentile -

- 50th Percentile I

w 0F8000011 Scatter Plot 0

Cs137 DcGL = 52.6 pCiIg 2.00E+00 7-1.50E+00

.00E+000 U,

0 0

0 0

0

.1OOE-O1

-O.49O S0 0

0

-5.00E-0 0.684 10OE+00 tNW f//fffý A

o° iMeasurement Locations 0

Activity -

Avere

"+3StDev

"-3tev

CD U)

CD) 00 F8000011 Frequency Plot Cs137 DCGL = 52.6 pCi/g 9 -

a1)

U-0 0

8-7-*

6-5-

4-2-

1 o04 tK' Z(N A z, Bins - Upper End Value (pCi/g)