Rancho Seco Final Status Survey Summary Report July 14, 2008 Electrical Penetration Room 209, 20' Auxiliary Building, Upper Walls and Ceiling Survey Unit F8131382 Date:
Prepared By:
iSS Engineer Reviewed By:7*
A 4
Q_
Date (C AJL(f, Lead FSS Engineer Approved By:
7 Date:
7 -
Dismantlement Superintendent, Radiological
FINAL STATUS SURVEY
SUMMARY
REPORT Survey Unit:
F8131382, Electrical Penetration Room 209, 20' Auxiliary Building, Upper Walls and Ceiling Survey Unit
Description:
Operating History: The reinforced concrete structure contained the RadWaste processing and supporting systems. The building contained six main elevations. Residual radioactive material was known to be present on all levels of the interior of the building.
Operating records and the HSA document several events with the potential for a release of radioactivity inside this structure. One report documented contamination of the auxiliary building roof. The roof was later replaced.
Site Characterization: Direct measurements were made of each of the interior elevation surfaces as well as the exterior surfaces of the structure. These measurements confirmed the presence of plant-derived radionuclides. Direct measurements on the -47' elevation showed a mean gross activity level of 320,071 dpm/1 00 cm 2 and a maximum value of 5,720,000 dpm/100 cm 2. Direct measurements on the -29' elevation showed a mean gross activity level of 544,756 dpm/100 cm 2 and a maximum value of 11,370,000 dpm/l 00 cm 2. Direct measurements on the -20' elevation showed a mean gross activity level of 247,831 dpmr/100 cm2 and a maximum value of 10,080,000 dpm/l00 cm 2. Direct measurements on the grade elevation showed a mean gross activity level of 373,758 dpm/100 cm 2 and a maximum value of 5,800,000 dpm/100 cm 2. Direct measurements on the +20' elevation showed a mean gross activity level of 85,408 dpm/100 cm 2 and a maximum value of 1,900,000 dpm/100 cm2. Direct measurements on the +40' elevation showed a mean gross activity level of 3,288 dpm/100 cm2 and a maximum value of 24,781 dpm/1oo cm 2. Direct measurements on the building exterior, including the mezzanine roof, showed a mean gross activity level of 1,897 dpm/100 cm2 and a maximum value of 2,990 dpm/100 cm 2. (The roof had been replaced prior to the classification survey.) Based on the classification procedure (DSIP-0020) and levels of gross activity reported, the interior of the auxiliary building was determined to be a Class 1, 2 area and the exterior was a Class 2,3. The Electrical Penetration Room 209 upper walls and ceiling were determined to be a Class 1.
HSA Events: HSA Report pg. 63.
Survey Unit Design Information:
The Survey Unit Design Parameters are presented in Table 1 below. The survey unit and measurement locations are depicted on the maps in Attachment 1. Direct measurement locations were determined using a random-start, fixed grid pattern and 312 m2 were scanned for 100% coverage. Samples of removable contamination were collected at each direct measurement location. The instrumentation used for the survey along with the MDC values are listed in Tables 2-1 and 2-2 in Attachment 2.
Page 2 of 10 FSS Summary Report F8131382
Table 1. Survey Unit Design Parameters Survey Design Value.
Comment Parameter Survey Area:
F813 Survey Unit:
Class:
SU Area (m2):
Evaluator:
DCGL (dpm/100 cm 2):
Area Factor:
Design DCGLemc (dpm/100 cm 2):
LBGR (dpm/100 cm 2).
Design Sigma (dpm/100 cm 2):
Type I Error:
Type II Error:
Predominant Nuclide:
Sample Area (m2):
Scan Area (m2):
Scan Coverage (%):
Sign P:
Calculated Relative Shift:
Relative Shift Used:
N-Value:
Design N-Value + 20%:
Design Min Samples N:
Grid Spacing L:
1382 1
312 Michael Stein 43000 3.6 154800 21500 5461 0.05 0.05 Cs-137 6.9 312 100%
1.645 1.645 0.99865 3.9 3
11 14 45 2.6 Electrical Penetration Room 209, 20' Auxiliary Building, Upper Walls and Ceiling Structure Surface LTP Table 5-4 Gross Activity DCGL Class 1 Class I Default = 50% DCGL Class 1 Class 1 Uses 3.0 if Relative Shift is
>3 NUREG-1575 Table 5-5 Class 1 Class 1 L
.1.
Page 3 of 10 FSS Summary Report F8131382
Survey Results:
A total of 63 direct measurements were made in F8131382. The results including mean, median, standard deviation and range are shown in Table 2. All direct measurements were less than the DCGL. None of the beta scan measurements indicated areas of elevated activity. Beta scan activity ranged from 1,563 to 45,196 dpm/100 cm 2, based on a surveyor efficiency of 0.5 and no background subtracted. None of the gamma scan measurements detected activity due to plant operations. Scan measurement locations for both beta and gamma emissions are identified in Attachment 1 of this report. Samples for removable surface activity were all less than 10% of the DCGL as shown in Table 3.
Removable surface activity samples were counted for alpha activity and none was detected at the MDC shown in Table 2-1 of Attachment 2.
Table 2. Direct Measurement Results Measurement ID Gross Activity (dpm/100 cm)
F8131382-CO001BD
.2225 F8131382-CO002BD
.2168 F8131382-CO003BD 1961 F8131382-CO004BD 2075 F8131382-CO005BD 1956 F8131382-CO006BD 1852 F8131382-CO007BD 1753 F8131382-CO008BD 2028 F8131382-CO009BD 1899 F8131382-CO01OBD 1888 F8131382-CO01IBD 1826 F8131382-CO012BD 1530 F8131382-CO013BD 1478 F8131382-CO014BD 1525 F8131382-CO015BD 1587 F8131382-CO016BD 1406 F8131382-CO017BD 1478 F8131382-CO018BD 1323 F8131382-CO019BD 1473 F8131382-CO02OBD 1395 F8131382-CO021BD 1432 F8131382-CO022BD 1665 F8131382-CO023BD 1442 F8131382-CO024BD 1452 F8131382-CO025BD 1790 F8131382-CO026BD 1592 F8131382-CO027BD 1551 F8131382-CO028BD 1136 F8131382-CO029BD 1359 F8131382-CO03OBD 1426 F8131382-CO031BD 1385 F8131382-CO032BD 1452 F8131382-CO033BD 1504 F8131382-CO034BD 1484 F8131382-CO035BD 1354 Page 4 of 10 FSS Summary Report F8131382
F8131382-CO036BD F8131382-CO037BD F8131382-CO038BD F8131382-CO039BD F8131382-CO04OBD F8131382-C0041 BD F8131382-CO042BD F8131382-CO043BD F8131382-CO044BD F8131382-CO045BD F8131382-CO046BD F8I31382-CO047BD F8131382-CO048BD F8131382-CO049BD F8131382-CO05OBD F8131382-C0051BD F8131382-CO052BD F8131382-CO053BD F8131382-CO054BD F8131382-CO055BD F8131382-CO056BD F8131382-CO057BD F8131382-CO058BD F8131382-CO059BD F8131382-CO06OBD F8131382-C0061BD F8131382-CO062BD F8131382-CO063BD Mean:
Median:
Standard Deviation:
Rancqe:
1421 1665 1437 1551 1629 1416 1546 1509 1541 1613 2448 2495 4710 2122 2303 1442 1442 1292 1323 1406 1229 1369 1338 1712 1509 1618 1556 1447 1666 1525 489 1136 -4710 Page 5 of 10 FSS Summary Report F8131382
Table 3. Removable Surface Activity Results Measurement ID Surface Beta Activity (dpm/100 cm 2)
F8131382C0001SM
-3.53 F8131382C0002SM
-3.53 F8131382C0003SM
-3.53 F8131382C0004SM
-3.53 F8131382C0005SM
-2.24 F8131382C0006SM
-0.95 F8131382C0007SM
-0.95 F8131382C0008SM
-3.53 F8131382C0009SM 0.34 F8131382C0010SM
-2.24 F8131382C0011SM
-3.53 F8131382C0012SM
-2.24 F8131382C0013SM
-2.24 F8131382C0014SM
-0.95 F8131382C0015SM 2.93 F8131382C0016SM
-0.95 F8131382C0017SM
-0.95 F8131382C0018SM
-0.95 F8131382C0019SM 0.34 F8131382C0020SM 1.64 F8131382C0021SM
-3.53 F8131382C0022SM
-6.11 F8131382C0023SM
-3.53 F8131382C0024SM 0.34 F8131382C0025SM
-2.24 F8131382C0026SM
-4.82 F8131382C0027SM 1.64 F8131382C0028SM 4.22 F8131382C0029SM
-2.24 F8131382C0030SM
-4.82 F8131382C0031SM
-2.24 F8131382C0032SM 5.51 F8131382C0033SM
-2.24 F8131382C0034SM
-0.95 F8131382C0035SM
-2.24 F8131382C0036SM
-0.95 F8131382C0037SM
-0.95 F8131382C0038SM
-2.24 F8131382C0039SM
-4.82 F8131382C0040SM
-3.53 F8131382C0041SM
-2.24 F8131382C0042SM 0.34 F8131382C0043SM
-2.24 F8131382C0044SM
-3.53 F8131382C0045SM
-0.95 F8131382C0046SM 19.72 F8131382C0047SM 11.97 F8131382C0048SM 36.5 F8131382C0049SM
-0.95 F8131382C0050SM
-0.95 Page 6 of 10 FSS Summary Report F8131382
F8131382C0051SM F8131382C0052SM F8131382C0053SM F8131382C0054SM F8131382C0055SM F8131382C0056SM F8131382C0057SM F8131382CO058SM F8131382C0059SM F8131382C0060SM F8131382C0061 SM F8131382C0062SM F8131382C0063SM Mean:
Median:
Standard Deviation:
Range:
-0.95
-4.82 0.34
-0.95
-2.24
-4.82
-3.53 4.22
-0.95
-2.24
-4.82
-3.53
-4.82
-0.6
-2.24 6.16
-6.11 to 36.5 Page 7 of 10 FSS Summary Report F8131382
Survey Unit Data Assessment:
The survey design required 45 direct measurements for the Sign Test. In actuality, 63 direct measurements were obtained. The critical value and the results of the Sign Test are presented in Table 4. The sample mean and median values were less than the DCGL. The sample standard deviation was less than the design standard deviation so no additional samples were required.
Page 8 of 10 FSS Summary Report F8131382
Table 4. Data Assessment Results Survey Results Parameter Value Comment Material Background Used (dpm/100 cm 2):
N/A Ambient Background Used (dpm/100 cm 2):
N/A Average Ambient BKG = 0 Actual Direct Measurements (N):
63 Median (dpm/100 cm 2):
1525 Mean (dpm/100 cm 2):
1666 Direct Measurement Standard Deviation 489 (dpm/100 cm 2):
Total Standard Deviation (dpmlO00 cm2):
489 Based on samples and backgrounds.
Maximum (dpm/100 cm 2):
4710 Material Type:
N/A Background Subtract Not Applied Sign Test Final N Value:
63 S+ Value:
63 Critical Value:
38 Sufficient Samples Collected:
Yes Maximum Value < DCGL:
Yes Median Value < DCGL:
Yes Mean Value < DCGL:
Yes Maximum Value < DCGLemc:
Yes Class 1 Total Standard Deviation <= Sigma:
Yes Pass the Sign Test?
Yes Reject the Null Hypothesis?
Yes Does the Survey Unit Pass All Criteria?
Yes Page 9 of 1. 0 FSS Summary Report F8131382
Survey Unit Investigations and Results:
No investigations were required for either direct or scan measurements and no investigation results are reported.
ALARA Statement:
As stated in Chapter 4 of the LTP, as long as the residual activity within the survey unit is less than the DCGL (i.e. the survey unit average activity is less than the DCGL and the EMC criterion has been met), the ALARA criterion has been met.
Changes in Initial Survey Unit Assumptions:
The survey unit was designed as a Class 1 structure survey and the sample results are consistent with that classification. The variability of the survey results was less than the characterization data used for survey design. No potential areas of elevated activity were detected.
==
Conclusion:==
The FSS of this survey unit was properly designed as a Class 1 survey based on Table 5-4 of the LTP. The required number of direct measurements was made and the scan coverage met the requirement of Table 5-6 of the LTP.No direct measurements exceeded the DCGL of 43000 dpm/100 cm2 and none of the removable surface activity measurements exceeded 10% of the DCGL. No investigations were required.
The direct measurement data support rejection of the null hypothesis, providing high confidence that the survey unit satisfied the release criteria and that the data quality objectives were met.
It is concluded that survey unit F8131382 meets the release criteria of 10CFR20.1402.
Page 10 of 10 FSS Summary Report F8131382 Maps July 14, 2008 Survey Unit F8131382
0
- 3
- 4 North Sample Line Chase Vertical Surfaces
[SamopleUna Chase Support #6 Vertical Surfaces S
E N
W.
South Sample [ine Chase Vertical Surfaces S E N W Sample Une Chase Support#7 Vertical Surfaces North 0
C
/-West F
- East, S*N Door Doom
- J Face Fac Wall "D" Wall "E" Wall "F" 2-Meter Lie CCC 0 4
ElEv. 2-10 RX Wall East
-It 00 00 IQ Wall "G" Top Of Vestibule Estimated Surface Area Upper Walls 204.5 me Ceiling 81.5 m' Sample Line Chase 25.7 m' Total 311 7 m2 L,,-5 WJ-
--.r 1.--
-W Wall "d" Wall "K" Wall "L Wall "M" Scale Fee 1 -0"
- SMUD SACRAMENTO MUNICIPAL UTILITY DISTRICT Samrple Line Chase Scale Meters 0 12 234 AUXILIARY BUILDING EL. 20' ROOM 209 GENERAL ARRANGEMENT - CEILING AND UPPER WALL SURFACE AREAS F8131382-Mi E:813000.04e SHEET 1 OF 6 T C HILL
_0 1
2 3
4 5I Ij 1L
0 I
Reflected Ceiling 00 00
- BETA SCAN CONTINUED ON AN ADJACENT SURFACE Scale Feet s*
1 1'-0" Line Chase Scale Meters 0
1 2
3
- SMUO SACRAMENTO MUNICIPAL UTILITY DISTRICT AUXILIARY BUILDING EL. 20' ROOM 209 CEILING AND UPPER WALL BETA SCAN MEASUREMENT LOCATIONS F8131382-Mi FILE: 813000.04e SHEET 2 of6 T C HILL
0C S
E -N W
Sample Line Chase Support #6 Vertical Surfaces KEY PLAN S
E -'N W
Sample Line Chase Support #7 Vertical Surfaces 10 rG)
'QH ED S
E N
W South Sample Line Chase Vertical Surfaces
- 1 403
- 2
~IIIIJ ci) cý (iQ
- 3
- 4
- 5 North Sample Line Chase Vertical Surfaces
- BETA SCAN CONTINUED ON AN ADJACENT SURFACE North Sample Line Chase Reflected Surface Q259) 00 00 Scale Feet a" = 1-0" Sample Line Scale Melers Chase 0 1 2
3 SMUD SACRAMENTO MUNICIPAL UTILITY DISTRICT AUXILIARY BUILDING EL. 20' ROOM 209 CEILING AND UPPER WALL BETA SCAN MEASUREMENT LOCATIONS F8131382-Mi FII F" R134flflf114d SHEET3 ofI6T HII I I
FILE: 813000 04e SHE 3 of6 T CHILL
(t~
0 Key Plan Wall "C" Facing Wall "D" 00 00 t.Q
- BETA SCAN CONTINUED ON AN ADJACENT SURFACE S ample Line Chase Scale Feet A" = 1V'-0" Scale Meters 0
1 2
3 oSMUO SACRAMENTO MUNICIPAL UTILITY DISTRICT AUXILIARY BUILDING EL. 20' ROOM 209 CEILING AND UPPER WALL BETA SCAN MEASUREMENT LOCATIONS F8131382-Mi FILE: 813000.04e SHEET 4of 6 T C, HILL FILE, 81 3000.04e SHEET 4 of 6 T CHILL
0D 0
Elev. 38'-6" (B-Q) ý CE 2-Meter Line Elev. 29'-10" Wall "F" Top Of Vestibule West Column Eley. 38'-6 2-Meter Line H
Elev. 29'-1" Wall "I" Wall "J"
- BETA SCAN CONTINUED ON AN ADJACENT SURFACE 00 00 LQ Sam*~
Line Chase Scale Feet
ý2"
= 1'-0" Scale Meters 0
1 2
3 AUXILIARY BUILDING EL. 20' ROOM 209 CEILING AND UPPER WALL BETA SCAN MEASUREMENT LOCATIONS F8131382-Mi
- 813000.04e SHEET 5 of6 T C
0 East Column Face (D GDG GGD CD GD-(2i)GD W-a Wall "K"
(/p 55 D.
West Column Face GDD 14 GD
~14112 141 (D 4,
Key Plan Wall "L" Wall "M"
- BETA SCAN CONTINUED ON AN ADJACENT SURFACE 00 00 Sampia Lim Chiase Scale Feet A" = 1'-0" Scale Meters 0
1 2
3 SMUD SACRAMENTO MUNICIPAL UTILITY DISTRICT AUXILIARY BUILDING EL. 20' ROOM 209 CEILING AND UPPER WALL BETA SCAN MEASUREMENT LOCATIONS F8131382-Mi FiIE FR~f~lflfld 4, SHEET 6of 6 TC.HILL IF11 F: - RIMnfl fliý SHEET 6 of 6 T C
00 0
":~~~~~.....
T.~)
o ~ p 1
1 114+4+4 H 11 1-.....
1"111' 1' 1":
- 41.
Aj V.........
..=.=.
T T-m '*.
-F
',,I','
,,I'
- Lf-I..............
K L:_i:
I.lane" SU 4
F3:1 V,
- Eat=-_
-3
,,,,,,I-..
R V._.
_1
]lllll~~~~...
.ll
.I
.II I
.i
.I 17 I I oI_
.Ic Ie AU IIAR BULDN 1 !0 ROO 209 A N DO M STA R
- ~ ~~~
T' TI T
T=,SCAET UIIA I................
M 2 Pon 3
,1.
)Y
_:JR Tlde Nolýl 0l N
E. t NMIE830.4 THE1F TCHL C.
.k Ws
- -Es It 00 00
0 O0 ITJ 00 00 tQ-2 Scale Feet 31" = 1V-0" SampW Line Cttaso Scale Meter 0
1 2
.3 AUXILIARY BUILDING EL. 20' ROOM 209 CEILING AND UPPER WALL BETA DIRECT/
LOOSE SURFACE MEASUREMENT POINTS F8131382-M2
CD 0
S E-N W Sample Line Chase Support #6 Vertical Surfaces DDHHD S
E N
W KEY PLAN Sample Line Chase Support #7 Vertical Surfaces C')
- 1 S~
71N7 North Sample Line Chase Vertical Surfaces South Sample Line Chase Vertical Surfaces 00 00 Scale Feet I" = V'-0" Samplb LkC Chase Scale Meters 0
1 2
3
- SMUD SACRAMENTO MUNICIPAL UTILITY DISTRICT AUXILIARY BUILDING EL. 20' ROOM 209 CEILING AND UPPER WALL BETA DIRECT/
LOOSE SURFACE MEASUREMENT POINTS F8131382-M2 FILE: 813000.04e SHEET 3 of 6 TCH
CDI 00 00 RX Wall Wall "A" Wall "B" Key Plan Elev. 38'-6" 2-Meter Line Elev. 26'-7" Scale Feet
?"
1 1'-0" Scale Meters 0
1 2
3 Wail "C" Sample Line Chase
- smun SACRAMENTO MUNICIPAL UTILITY DISTRICT AUXILIARY BUILDING EL. 20' ROOM 209 CEILING AND UPPER WALL BETA DIRECT/
LOOSE SURFACE MEASUREMENT POINTS F8131382-M2 FILE: 813000.04e SHEET4 of 6 TCH ILL
East Column Face
-West Column Face (D~
0 Wall "F" Wall "G" Wall "H" Key Plan Top Of Vestibule West Column Elev. 38'-6" 2-Meter Line Elev. 26'-7" Wall "I" Wall "J"
'"71 00 00 Samp*
Line Chase Scale Feet A" = 1'-0" Scale Meters 0
1 2
3 S SMUD SACRAMENTO MUNICIPAL UTILITY DISTRICT AUXILIARY BUILDING EL. 20' ROOM 209 CEILING AND UPPER WALL BETA DIRECT/
LOOSE SURFACE MEASUREMENT POINTS F8131382-M2 FILE: 813000.04e SHEET 5 of 6 TCH ILL
CD 0
East Column Key Plan Wall "K" Wall "M"
'It 00 00 Sampb Line Chase Scale Feel A"
= 1'-0" Scale Meter*
0 1
2 3
SMUD SACRAMENTO MUNICIPAL UTILITY DISTRICT AUXILIARY BUILDING EL. 20' ROOM 209 CEILING AND UPPER WALL BETA DIRECT/
LOOSE SURFACE MEASUREMENT POINTS F8131382-M2 FILE: 813000.04e SHEET 6 of 6 TCHILL
0 i'0 ITj 00 00 IQ Sampla tine Chase Scale Feet Il = 1'-O" Scale Meters 0
1 2
3 SMUD SACRAMENTO MUNICIPAL UTILITY DISTRICT AUXILIARY BUILDING EL. 20' ROOM 209 CEILING AND UPPER WALL JUNCTURE BETA SCAN MEASUREMENT LOCATIONS F8131382-M3 HL F81300 04e ln SHEEnT OF.5 TCHILL
0 J83 S
E N
W Sample Line Chase Support #6 Vertical.
Surfaces t n, KEY PLAN S
E N
W Sample Line Chase Support #7 Vertical Surfaces 00 00 t'j
- 1
- 2 E
N W
South Sample Line ChaseVertical Surfaces South Sample Line Chase Reflected Surface i
J93 -
- 3
- 4
- 5 North Sample Line Chase Vertical Surfaces North Sample Line Chase Reflected Surface I I Sainp&a Linm Chase Scale Feet S -0" Scale Meters
- SMUD SACRAMENTO MUNICIPAL UTILITY DISTRICT rig c AUXILIARY BUILDING EL. 20' ROOM 209 CEILING AND UPPER WALL JUNCTURE BETA SCAN MEASUREMENT LOCATIONS F8131382-M3
- 813000.04e SHEET 2 of 5 T C 0
1 2
3 HILL
I CD 0
A",
-Rellected North SOieO Celng North Column Face Elev. 38'-6" 2-Meter Line Elev. 29'-10" J14 Wall "E" Wall "C" Jig*-/
Wall "D" ipper jiam It00 00 Note: 'Continued on adaceintSurface Sample Lime Chase Scale Feet A" = 1V-0" Scale Meters 0
1 2
3 SMUD SACRAMENTO MUNICIPAL UTILITY DISTRICT AUXILIARY BUILDING EL. 20' ROOM 209 CEILING AND UPPER WALL JUNCTURE BETA SCAN MEASUREMENT LOCATIONS F8131382-M3 FitE Fi1.iflftflf4d SHEET 3rtf5T HILL FILE, 813000 04e SHEET 3 Of5 T CHILL
East Column (D
0 k)t
- Elev. 38'-6" 2-Meter Line Elev. 29-10" Wall "F" W all "G "
74 Top Of Vestibule Wall "H" Elev. 38'-6" J52 2-Meter Line Elev. 29'-10".
Wall "I" Wall "J" It 00 00 tQJ Sawp&a Lbne Chase Scale Feet A" = 1'-0" Scale Meters 0
1 2
3
- SMUD SACRAMENTO MUNICIPAL UTILITY DISTRICT AUXILIARY BUILDING EL. 20' ROOM 209 CEILING AND UPPER WALL JUNCTURE BETA SCAN MEASUREMENT LOCATIONS F8131382-M3 FILE: 813000.04e SHEET 4 of 5 T C HILL
00 0*
East Column Face J43 J48 Wall "K"
.138
" -39 J137 Key Plan N.J3 Wall "L" Wall "M" It 00 00 1"J Sample Line Chase Scale Feet A"
=
1'-0" Scale Meters 0
1 2
3
- SMU SACRAMENTO MUNICIPAL UTILITY 0 ISTRICT AUXILIARY BUILDING EL. 20' ROOM 209 CEILING AND UPPER WALL JUNCTURE BETA SCAN MEASUREMENT LOCATIONS F8131382-M3 FIItF.R1?.flflfl0,4e SHEETS5of 5 T C HLL i
11 F-RIMAn ndý SHE 50f5 T C HILL
CD 0
00 00 Sampl Linm Chase Scale Feet I" = 1,-0" Scale Meters 0
1 2
3 S
SMUD SACRAMENTO MUNICIPAL UTILITY DISTRICT AUXILIARY BUILDING EL. 20' ROOM 209 CEILING AND UPPER WALL PENETRATION BETA SCAN MEASUREMENT LOCATIONS F8131382-M4 FfIlF:R1.3fllfldeR4 SHEET 1 OF 5T
]Ha~
FILE: 813000 04e SHEET I OF 5 T CH ILL
CLI t'Q 0
S E
N W Sample Line Chase Support #6 Vertical Surfaces S
E N W KEY PLAN Sample Line Chase Support #7 Vertical Surfaces
- 1
- 2 S
E N
W South Sample Line Chase Vertical Surfaces South Sample Line Chase Reflected Surface 71111D
- 3
- 4
- 5 North Sample Line Chase Vertical Surfaces North Sample Line Chase Reflected Surface
.1 III 00 L0 00 1'.)
Scale Feet A" = 1'-0" Sample Line Chase Scale Meters 0
1' 2
3
- SMUD AUXILIARY BUILDING EL. 20' ROOM 209 CEILING AND UPPER WALL PENETRATION BETA SCAN MEASUREMENT LOCATIONS F8131382-M4 SACRAMENTO MUNICIPAL UTILITY DISTRICT
0 k)
I I
Reflected North SkIeOfCe"g
/_*
,.,. k.
..N..
. :,. : * * :
- i North Column Face Elev. 38'-6" 2-Meter Line P5 P6 P1 P2 P3 P4 0
0 0
0 Elev. 2' RX Wall Wall Facing South/
Elev. 38'-6" Su P8 2-Meter Line Elev. 29;-10" Key Plan Wall "E" Wall "C" Wall "D" 00 00 Sample Li*e Chase Scale Feet A" = 1V-0" Scale Meters 0
1 2
3 oSMUD SACRAMENTO MUNICIPAL UTILITY DISTRICT AUXILIARY BUILDING EL. 20' ROOM 209 CEILING AND UPPER WALL PENETRATION BETA SCAN MEASUREMENT LOCATIONS F8131382-M4 FILE: 813000.04le SH-EET 3of 5 T CHILL I
FILE: 813000 134e SHEET 3 of5 T C HILL
I'0 0
Elev. 38'-6" P12 2-Meter Line Elev. 29'-10" Wall "F" Wall "G" Top Of Vestibule Elev. 38'-6" P35 P39.
P41 P40'
- 2-Meter Line Elev. 29'-10" P36 P37 L
It 00 00 Wall "I" Scale Feet 12"
= 1'-0" Scale Meters Wall "J" Sampla Line Chase
- SMUI SACRAMENTO MUNICIPAL UTILITY DISTRICT AUXILIARY BUILDING EL. 20' ROOM 209 CEILING AND UPPER WALL PENETRATION BETA SCAN MEASUREMENT LOCATIONS F8131382-M4 FfI F"R1.flflflflA*
SHEET 4 nfU Tn 0
1 2
3 Hi-ll FILE: 813000 04e SHEET 4 of5 T CHLL
crC t'Q 0
-t cI~
East Column Face P63
-A Column P56-P57 0.
P77 p
Wall 'M" Key Plan Wall "K" Wall "L" 00 00 Sample Line Chase Scale Feet A"= 1 '-0 Sc123Mte
- SMUD SACRAMENTO MUNICIPAL UTILITY DISTRICT AUXILIARY BUILDING EL. 20' ROOM 209 CEILING AND UPPER WALL PENETRATION BETA SCAN MEASUREMENT LOCATIONS F8131382-M4 FILE: 813000.04e SHEET 5 of5 T C HILL
IQ 0
Elev. 38'-6"-
->9...
P:5 P'6 P1 P2 P3 P4 2-Meter Line Elev. 29'-10" RX Wall 00 00 t'Q s~mpla LinIe chase Scale Feet A"
= 1'-0" Scale Meters 0
1 2
3
- SMUI SACRAMENTO MUNICIPAL UTILITY DISTRICT AUXILIARY BUILDING EL. 20' ROOM 209 CEILING AND UPPER WALL PENETRATION GAMMA SCAN MEASUREMENT LOCATIONS F8131382-M5 FILE: 813000.04e SHEET 1 of I T C HILL Instrumentation July 14, 2008 Survey Unit F8131382
Table 2-1. Survey Unit Instrumentation Instrument Detector MDC Static MDC Scan Model; Serial No.
Model; Serial No.
(dpm/100 cm2 )
(dpm/100 cm2 )
M2350; 142514 43-98B; 148639 930 1680 M2350; 180733 43-98B; 148638 930 1680 M2350; 180733 43-94B; 148620 350 610 M2350; 175834 43-68B; 190482 433 1033 M2350; 193700 43-68B; 190294 433 1033 M2350; 142509 43-68B; 160699 433 1033 M2350; 175834 43-68B; 148634 433 1033 M2350; 149789 43-68B; 148633 433 1033 M2350; 149789 43-116-1B; 256006 796 3258 M2350; 175834 43-116-IB; 190642 796 3258 M2350; 180733 43-i11B; 148641 2290 4160 Tennelec; 0401171 N/A 5.9 dpm (x, N/A 11.7 dpmr 4830 Cs-137 InSpector 1000 03069793 N/A 530 Co-60 5350 Co-60 The scan and static MDC's provided represent the most conservative MDC values for the survey conducted.
Table 2-2. Investigation Criteria and DCGL Value Param eter V l eC 2
(dpm/100 cm2)
Investigation Criteria - Direct 154800 Investigation Criteria - Scan 154800 DCGLw 43000 DCGLEMC 154800 Page 2 of 2 Att. 2 Instrumentation F8131382 Investigation July 14, 2008 Survey Unit F8131382 (none required)
Data Assessment July 14, 2008 Survey Unit F8131382
F8131382 Gross Activity Sample Results Quantile Plot OtM DCGL = 43000 dpm/100cm2 5,000 4,500 0401 4,000 S3,500 3,000 2,500 En 1n
,000
.1500 152 0
0 20 40 60 s0 100 Percentile
-0 Direct Measurements (dprn/IO0cr2) median
-75th Percentile
- - -- 50th Percentile 00
0 F8131382 Gross Activity Sample Results Scatter Plot DCGL = 43000 dpm1100cmn C'D 00 00 Il 5000 4500 4000
, 3500 S1500 1000 500 0
0 00 0 0 0
o00 000 00 00 0
-- --- 0
- o--
,* a
_- -*o 000000000000 00000000
-000 Es 1
3134 l1os 0oo0o0ooaooo0oo0ooooooooooooo wmwmmmt nMeasmumientrLocations MeasurementLocaions 0
Gross Activity -
Average -
"+aStDev" -
"-3StDev"I
.0 0
F81 31382 Gross Activity Frequency Plot DCGL = 43000 dpm/1 00cm 2 0
Ci)
O0 00 00o LL I
36 34 32 30 28 26 24 22 20 18 16 14 12 10 8
6 4
2 0
C\\1 N
0 Bins - Upper End Value (dpmll OOcm2)