Letter Sequence Withdrawal |
---|
TAC:MD7420, Containment Structural Integrity (Withdrawn, Closed) |
|
MONTHYEARNG-07-0729, Technical Specification Change Request, TSCR-094, Application for TS Improvement to Adopt TSTF-343, Revision 1,Affected Technical Specification: Section 5.5.122007-11-14014 November 2007 Technical Specification Change Request, TSCR-094, Application for TS Improvement to Adopt TSTF-343, Revision 1,Affected Technical Specification: Section 5.5.12 Project stage: Request ML0810601482008-04-0303 April 2008 RAI, MD7420- Draft - Request for Additional Information Project stage: Draft RAI NG-08-0303, Withdrawal of Technical Specification Change Request TSCR-094 Application for Technical Specification Improvement to Adopt TSTF-343, Revision 1, Containment Structural Integrity, to Add Exception for Visual Inspection of Containment2008-04-23023 April 2008 Withdrawal of Technical Specification Change Request TSCR-094 Application for Technical Specification Improvement to Adopt TSTF-343, Revision 1, Containment Structural Integrity, to Add Exception for Visual Inspection of Containment Project stage: Withdrawal ML0813503512008-05-30030 May 2008 Withdrawal of an Amendment. Adoption of TSTF Standard Technical Specification Change Traveler, TSTF-343, Rev. 1 Containment Structural Integrity. Project stage: Withdrawal 2008-04-23
[Table View] |
|
---|
Category:Federal Register Notice
MONTHYEARML21224A0192021-09-0909 September 2021 PSDAR Meeting FRN, Duane Arnold Energy Center Post-Shutdown Decommissioning Activities Report ML21214A2732021-08-0404 August 2021 PSDAR Comment Extension FRN - August 2021 ML21068A2402021-05-12012 May 2021 Onsite Insurance Exemption FRN ML21070A1022021-05-12012 May 2021 Offsite Insurance Exemption FRN ML21097A1482021-04-13013 April 2021 Federal Register Notice (FRN) for Emergency Planning Exemption ML21062A2802021-03-16016 March 2021 Enclosure - Duane Arnold Emergency Planning Exemption EA ML21048A0722021-03-0202 March 2021 Post Shutdown Activities Report (PSDAR) Comment Extension FRN ML21028A0122021-02-18018 February 2021 FRN - Notice of Issuance of Multiple Exemptions Regarding Various Parts of 10 CFR Due to COVID-19 Impacts for January 2021 ML20335A0902020-12-21021 December 2020 Federal Register Notice - November 2020 COVID-19 Exemptions ML20288A7372020-10-20020 October 2020 FRN, Notice to Reopen the Comment Period Related to the Post-Shutdown Decommissioning Activities Report and Site-Specific Decommissioning Cost Estimate ML20288A6952020-10-16016 October 2020 Letter, Notice to Extend the Comment Period Related to the Post-Shutdown Decommissioning Activities Report and Site-Specific Decommissioning Cost Estimate ML20171A6292020-08-13013 August 2020 FRN, Exemption from 10 CFR 50.82(a)(8)(i)(A) and Section 75(H)(1)(IV) to Allow Use of Funds from Decommissioning Trust Fund for Spent Fuel Management and Site Restoration Activities ML20164A0002020-07-30030 July 2020 FRN, Finding of No Significant Impact with Associated Environmental Assessment Use of Decommissioning Trust Fund for Spent Fuel Management and Site Restoration ML20164A0012020-07-30030 July 2020 Letter, Finding of No Significant Impact with Associated Environmental Assessment Use of Decommissioning Trust Fund for Spent Fuel Management and Site Restoration ML19266A0122019-11-12012 November 2019 FRN -Duane Arnold Energy Center - Exemption from the Requirements of 10 CFR Part 73, Sections 73.55(P)(1)(I) and (P)(1)(Ii) Related to the Suspension of Security Measures in an Emergency or During Severe Weather ML19168A0842019-06-26026 June 2019 Biweekly Federal Register Notice - Applications and Amendments to Facility Operating Licenses and Combined Licenses Involving No Significant Hazards Considerations - Publication Date: 07/02/2019 ML18274A0662018-10-0303 October 2018 FRN - Notice of Withdrawal NRC-2018-0116, Duane Arnold Energy Center - FRN - Notice of Withdrawal2018-10-0303 October 2018 Duane Arnold Energy Center - FRN - Notice of Withdrawal ML18250A0552018-09-21021 September 2018 FRN -Notice of Withdrawal NRC-2018-0045, Duane Arnold Energy Center - FRN -Notice of Withdrawal2018-09-21021 September 2018 Duane Arnold Energy Center - FRN -Notice of Withdrawal ML18165A3972018-06-20020 June 2018 FRN - Withdrawal of Amendment Request for Adoption of 10 CFR 50.69 Risk-Informed Categorization and Treatment of Structures, Systems, and Components (Sscs) for Nuclear Power Reactors NRC-2018-0123, Duane Arnold Energy Center FRN - Withdrawal of Amendment Request for Adoption of 10 CFR 50.69 Risk-Informed Categorization and Treatment of Structures, Systems, and Components (Sscs) for Nuclear Power Reactors2018-06-20020 June 2018 Duane Arnold Energy Center FRN - Withdrawal of Amendment Request for Adoption of 10 CFR 50.69 Risk-Informed Categorization and Treatment of Structures, Systems, and Components (Sscs) for Nuclear Power Reactors ML17256A9132017-09-26026 September 2017 Environmental Assessment and Finding of No Significant Impact; Issuance NRC-2017-0200, Duane Arnold Energy Center - Environmental Assessment and Finding of No Significant Impact; Issuance2017-09-26026 September 2017 Duane Arnold Energy Center - Environmental Assessment and Finding of No Significant Impact; Issuance ML16271A0922016-09-28028 September 2016 Biweekly Federal Register Notice - Applications and Amendments to Facility Operating Licenses and Combined Licenses Involving No Significant Hazards Considerations - Publication Date: October 11, 2016 ML16257A5172016-09-19019 September 2016 Biweekly FRN - Applications and Amendments to Facility Operating Licenses and Combined Licenses Involving No Significant Hazards Considerations - Publication Date: September 27, 2016 NRC-2016-0202, Biweekly FRN - Applications and Amendments to Facility Operating Licenses and Combined Licenses Involving No Significant Hazards Considerations - Publication Date: September 27, 20162016-09-19019 September 2016 Biweekly FRN - Applications and Amendments to Facility Operating Licenses and Combined Licenses Involving No Significant Hazards Considerations - Publication Date: September 27, 2016 ML16215A2272016-08-0303 August 2016 Biweekly Federal Register Notice - Applications and Amendments to Facility Operating Licenses and Combined Licenses Involving No Significant Hazards Considerations - Publication Date: August 16, 2016 NRC-2016-0161, Biweekly Federal Register Notice - Applications and Amendments to Facility Operating Licenses and Combined Licenses Involving No Significant Hazards Considerations - Publication Date: August 16, 20162016-08-0303 August 2016 Biweekly Federal Register Notice - Applications and Amendments to Facility Operating Licenses and Combined Licenses Involving No Significant Hazards Considerations - Publication Date: August 16, 2016 NRC-2015-0260, 11/20/15 - Federal Register Notice on Applications and Amendments to Facility Operating Licenses and Combined Licenses Involving Proposed No Significant Hazards Considerations and Containing SUNSI and Order Imposing Procedures for Acce2015-11-20020 November 2015 11/20/15 - Federal Register Notice on Applications and Amendments to Facility Operating Licenses and Combined Licenses Involving Proposed No Significant Hazards Considerations and Containing SUNSI and Order Imposing Procedures for Access to ML15307A1992015-11-20020 November 2015 Federal Register Notice on Applications and Amendments to Facility Operating Licenses and Combined Licenses Involving Proposed No Significant Hazards Considerations and Containing SUNSI and Order Imposing Procedures for Access to SUNSI ML15120A2272015-05-0101 May 2015 Biweekly FRN - Applications and Amendments to Facility Operating Licenses and Combined Licenses Involving No Significant Hazards Considerations - Publication Date: May 12, 2015 NRC-2015-0009, G20110262 - FRN - Paul Gunter and Kevin Kamps Letter 2.206 - Immediately Suspend the Operating License of General Electric Boiling Water Reactors Mark I Units2015-01-15015 January 2015 G20110262 - FRN - Paul Gunter and Kevin Kamps Letter 2.206 - Immediately Suspend the Operating License of General Electric Boiling Water Reactors Mark I Units ML14335A6302015-01-15015 January 2015 G20110262 - Final Response to Paul Gunter and Kevin Kamps Letter 2.206 - Immediately Suspend the Operating License of General Electric Boiling Water Reactors Mark I Units ML14335A6482015-01-15015 January 2015 G20110262 - FRN - Paul Gunter and Kevin Kamps Letter 2.206 - Immediately Suspend the Operating License of General Electric Boiling Water Reactors Mark I Units NRC-2014-0262, Federal Register Notice on Applications and Amendments to Facility Operating Licenses and Combined Licenses Involving Proposed No Significant Hazards Considerations and Containing SUNSI and Order Imposing Procedures for Access to SUNSI2014-12-11011 December 2014 Federal Register Notice on Applications and Amendments to Facility Operating Licenses and Combined Licenses Involving Proposed No Significant Hazards Considerations and Containing SUNSI and Order Imposing Procedures for Access to SUNSI - Ja ML14336A4122014-12-11011 December 2014 Federal Register Notice on Applications and Amendments to Facility Operating Licenses and Combined Licenses Involving Proposed No Significant Hazards Considerations and Containing SUNSI and Order Imposing Procedures for Access to SUNSI - Ja ML13225A5572013-08-12012 August 2013 Rescission of Certain Security Orders Concerning Spent Nuclear Fuel in Transit ML13228A3992013-08-12012 August 2013 Letter to Holders of Independent Spent Fuel Storage Installation (ISFSI) Licenses Re Rescission of Certain Security Orders Concerning Spent Nuclear Fuel in Transit - Rin 3150-AI64 (NRC-2009-0163) EA-02-109 ML13015A4952013-01-24024 January 2013 Withdrawal of an Amendment Request ML13015A6292013-01-24024 January 2013 Withdrawal of an Amendment Request (Fr Notice) NRC-2013-0022, Duane Arnold Energy Center - Withdrawal of an Amendment Request (Fr Notice)2013-01-24024 January 2013 Duane Arnold Energy Center - Withdrawal of an Amendment Request (Fr Notice) ML12056A0432012-03-12012 March 2012 Order Modifying Licenses with Regard to Reliable Hardened Containment Vents - to All Operating Boiling Water Reactor Licensees with Mark I and Mark II Containments ML12056A0442012-03-12012 March 2012 Order Modifying Licenses with Regard to Reliable Spent Fuel Pool Instrumentation (Effective Immediately) - to All Power Reactor Licensees and Holders of Construction Permits in Active or Deferred Status NRC-2012-0067, Order Modifying Licenses with Regard to Reliable Spent Fuel Pool Instrumentation (Effective Immediately) - to All Power Reactor Licensees and Holders of Construction Permits in Active or Deferred Status2012-03-12012 March 2012 Order Modifying Licenses with Regard to Reliable Spent Fuel Pool Instrumentation (Effective Immediately) - to All Power Reactor Licensees and Holders of Construction Permits in Active or Deferred Status NRC-2012-0069, Order Modifying Licenses with Regard to Reliable Hardened Containment Vents - to All Operating Boiling Water Reactor Licensees with Mark I and Mark Ii Containments2012-03-12012 March 2012 Order Modifying Licenses with Regard to Reliable Hardened Containment Vents - to All Operating Boiling Water Reactor Licensees with Mark I and Mark Ii Containments NRC-2011-0230, FRN: General Notice. Biweekly Notice - Applications and Amendments to Facility Operating Licenses Involving No Significant Hazards Considerations2011-09-22022 September 2011 FRN: General Notice. Biweekly Notice - Applications and Amendments to Facility Operating Licenses Involving No Significant Hazards Considerations ML1126504892011-09-22022 September 2011 FRN: General Notice. Biweekly Notice - Applications and Amendments to Facility Operating Licenses Involving No Significant Hazards Considerations NRC-2011-0187, Biweekly Sholly Report - Applications and Amendments to Facility Operating Licenses Involving No Significant Hazards Considerations; Fr Publication Date: 8/23/20112011-08-11011 August 2011 Biweekly Sholly Report - Applications and Amendments to Facility Operating Licenses Involving No Significant Hazards Considerations; Fr Publication Date: 8/23/2011 ML1122302752011-08-11011 August 2011 Biweekly Sholly Report - Applications and Amendments to Facility Operating Licenses Involving No Significant Hazards Considerations; Fr Publication Date: 8/23/2011 2021-09-09
[Table view] Category:Letter
MONTHYEARL-2024-010, Point Units 3 and 4, Seabrook, Duane Arnold, and Point Beach Units 1 and 2, Nuclear Property Insurance - 10 CFR 50.54(w)(3)2024-01-25025 January 2024 Point Units 3 and 4, Seabrook, Duane Arnold, and Point Beach Units 1 and 2, Nuclear Property Insurance - 10 CFR 50.54(w)(3) NG-23-0010, Supplement to Duane Arnold Exemption Request Regarding Enhanced Weapons, Firearms Background Checks, and Security Event Notifications Final Rule2023-12-0606 December 2023 Supplement to Duane Arnold Exemption Request Regarding Enhanced Weapons, Firearms Background Checks, and Security Event Notifications Final Rule NG-23-0009, Part 73 Exemption Request Regarding Enhanced Weapons, Firearms Background Checks, and Security Event Notifications Final Rule2023-11-16016 November 2023 Part 73 Exemption Request Regarding Enhanced Weapons, Firearms Background Checks, and Security Event Notifications Final Rule ML23201A0872023-08-0303 August 2023 Audit Plan in Support of Review of License Amendment NG-23-0006, Independent Spent Fuel Storage Installation (ISFSI) Financial Assurance Update2023-05-23023 May 2023 Independent Spent Fuel Storage Installation (ISFSI) Financial Assurance Update ML23137A1672023-05-11011 May 2023 Submittal of 2022 Annual Radiological Environmental Operating Report NG-23-0004, 2022 Annual Radioactive Material Release Report2023-04-25025 April 2023 2022 Annual Radioactive Material Release Report NG-23-0003, 2022 Annual Exposure Report - Form 5s2023-04-21021 April 2023 2022 Annual Exposure Report - Form 5s NG-23-0002, 10 CFR 50.59 Report, Commitment Changes, 10 CFR 72.48 Report, Quality Assurance Program Changes, Technical Specification Basis Changes, and Revision of the DAEC Defueled Safety Analysis Report2023-03-27027 March 2023 10 CFR 50.59 Report, Commitment Changes, 10 CFR 72.48 Report, Quality Assurance Program Changes, Technical Specification Basis Changes, and Revision of the DAEC Defueled Safety Analysis Report NG-23-0001, 2023 Annual Decommissioning and Spent Fuel Management Funding Status Report2023-03-27027 March 2023 2023 Annual Decommissioning and Spent Fuel Management Funding Status Report L-2023-029, and Point Beach Units 1 and 2 Nuclear Property Insurance - 10 CFR 50.54(w)(3)2023-03-10010 March 2023 and Point Beach Units 1 and 2 Nuclear Property Insurance - 10 CFR 50.54(w)(3) ML22361A1022023-02-24024 February 2023 Reactor Decommissioning Branch Project Management Changes for Some Decommissioning Facilities and Establishment of Backup Project Manager for All Decommissioning Facilities ML22339A0012022-12-22022 December 2022 Acceptance of Requested Licensing Action Amendment Request for Common Emergency Plan IR 05000331/20220032022-12-13013 December 2022 NRC Inspection Report No. 05000331/2022003 (Drss) ML22285A0072022-10-13013 October 2022 NRC Analysis of NextEra Energy Duane Arnold'S Decommissioning Funding Status Report, Docket No. 50-331 IR 05000331/20220022022-07-13013 July 2022 NRC Inspection Report Nos. 05000331/2022002(DNMS) and 07200032/2022002(DNMS) ML22090A1922022-05-26026 May 2022 Letter to B. Coffey, FPL from M. Doell - Duane Arnold Post Shutdown Activities Report Review Letter ML22132A2872022-05-24024 May 2022 ISFSI DQAP Approval Letter ML22111A0332022-05-20020 May 2022 Operating License Page Correction Letter to B. Coffey, Florida Power and Light, from M. Doell NG-22-0055, Revision to Duane Arnold Energy Center (DAEC) ISFSI-Only Emergency Plan2022-05-20020 May 2022 Revision to Duane Arnold Energy Center (DAEC) ISFSI-Only Emergency Plan ML22089A0492022-05-12012 May 2022 Sfmp Review Letter NG-22-0053, 2021 Annual Radiological Environmental Operating Report2022-05-0606 May 2022 2021 Annual Radiological Environmental Operating Report NG-22-0052, Regulatory Issue Summary 2000-11. NRC Emergency Telecommunications System, Statement of Intent to Implement the Proposed Voluntary Initiative2022-05-0404 May 2022 Regulatory Issue Summary 2000-11. NRC Emergency Telecommunications System, Statement of Intent to Implement the Proposed Voluntary Initiative IR 05000331/20224012022-04-27027 April 2022 Decommissioning Security Inspection Report 05000331/2022401 NG-22-0050, Revised Response to Request for Additional Information Relating to Decommissioning Quality Assurance Program, Revision 02022-04-26026 April 2022 Revised Response to Request for Additional Information Relating to Decommissioning Quality Assurance Program, Revision 0 NG-22-0049, 2021 Annual Radioactive Material Release Report2022-04-26026 April 2022 2021 Annual Radioactive Material Release Report L-2022-068, NextEra Energy Duane Arnold Quality Assurance Topical Report (FPL-3) Revision 22022-04-25025 April 2022 NextEra Energy Duane Arnold Quality Assurance Topical Report (FPL-3) Revision 2 ML22066A7632022-04-25025 April 2022 ISFSI-Only Emergency Plan License Amendment Approval NG-22-0035, Response to Request for Additional Information Relating to Decommissioning Quality Assurance Program. Revision 02022-04-13013 April 2022 Response to Request for Additional Information Relating to Decommissioning Quality Assurance Program. Revision 0 NG-22-0047, Registration of Independent Spent Fuel Installation Storage Cask and Notification of Permanent Removal of All Spent Fuel Assemblies from the Spent Fuel Pool2022-04-11011 April 2022 Registration of Independent Spent Fuel Installation Storage Cask and Notification of Permanent Removal of All Spent Fuel Assemblies from the Spent Fuel Pool NG-22-0042, Registration of Independent Spent Fuel Installation Storage Casks2022-04-0808 April 2022 Registration of Independent Spent Fuel Installation Storage Casks NG-22-0041, and Independent Spent Fuel Storage Installation, 2022 Annual Decommissioning and Spent Fuel Management Funding Status Report2022-03-31031 March 2022 and Independent Spent Fuel Storage Installation, 2022 Annual Decommissioning and Spent Fuel Management Funding Status Report NG-22-0031, 2021 Annual Exposure Report - Form 5s2022-03-23023 March 2022 2021 Annual Exposure Report - Form 5s NG-22-0030, Registration of Independent Spent Fuel Installation Storage Casks2022-03-23023 March 2022 Registration of Independent Spent Fuel Installation Storage Casks ML22080A1822022-03-22022 March 2022 Letter to B. Coffey from M. Doell - Duane Arnold ISFSI QAPD RAI Letter L-2022-012, Florida Power & Light Company Nuclear Property Insurance - 10 CFR 50.54(w)(3)2022-03-16016 March 2022 Florida Power & Light Company Nuclear Property Insurance - 10 CFR 50.54(w)(3) ML22059A7462022-03-10010 March 2022 ISFSI-Only Physical Security Plan License Amendment Approval NG-22-0025, Registration of Independent Spent Fuel Installation Storage Casks2022-03-0808 March 2022 Registration of Independent Spent Fuel Installation Storage Casks IR 05000331/20220012022-03-0404 March 2022 Subject: NRC Inspection Report Nos. 05000331/2022001(DNMS) and 07200032/2022001(DNMS) NG-22-0021, Registration of Independent Spent Fuel Installation Storage Casks2022-02-24024 February 2022 Registration of Independent Spent Fuel Installation Storage Casks ML22007A2722022-02-11011 February 2022 Cover Letter - NRC Duane Arnold Exemption Issuance NG-22-0014, Registration of Independent Spent Fuel Installation Storage Casks2022-02-10010 February 2022 Registration of Independent Spent Fuel Installation Storage Casks ML22028A2822022-02-0303 February 2022 Defueled Physical Security Plan License Amendment Approval ML22033A0802022-02-0202 February 2022 Supplement to License Amendment Request (TSCR-188): Proposed Change to the Physical Security Plan for the Post-Shutdown and Permanently Defueled Condition IR 05000331/20210012022-01-25025 January 2022 NRC Inspection Report Nos. 05000331/2021001(DNMS); 07200032/2021001(DNMS); and 07200032/2021002(DNMS) - Duane Arnold Energy Center ML21172A2172022-01-21021 January 2022 Issuance of License Amendment to Adopt ISFSI-Only Technical Specifications NG-22-0009, Registration of Independent Spent Fuel Installation Storage Casks2022-01-20020 January 2022 Registration of Independent Spent Fuel Installation Storage Casks NG-22-0001, Supplement to Exemption Request for Failed Fuel Can Weight in a Certificate of Compliance 1004 Renewed Amendment 17 61BTH Type 2 Dry Shielded Canister2022-01-0606 January 2022 Supplement to Exemption Request for Failed Fuel Can Weight in a Certificate of Compliance 1004 Renewed Amendment 17 61BTH Type 2 Dry Shielded Canister NG-21-0038, Registration of Independent Spent Fuel Installation Storage Casks2021-12-22022 December 2021 Registration of Independent Spent Fuel Installation Storage Casks NG-21-0035, Supplement to Exemption Request for Failed Fuel Can Weight in a Certificate of Compliance 1004 Renewed Amendment 17 61 Bth Type 2 Dry Shielded Canister2021-12-10010 December 2021 Supplement to Exemption Request for Failed Fuel Can Weight in a Certificate of Compliance 1004 Renewed Amendment 17 61 Bth Type 2 Dry Shielded Canister 2024-01-25
[Table view] |
Text
May 30, 2008 Mr. Richard L. Anderson Vice President Duane Arnold Energy Center 3277 DAEC Road Palo, IA 52324-9785
SUBJECT:
DUANE ARNOLD ENERGY CENTER - WITHDRAWAL OF AN AMENDMENT REQUEST PERTAINING TO THE ADOPTION OF TECHNICAL SPECIFICATION TASK FORCE (TSTF) STANDARD TECHNICAL SPECIFICATION CHANGE TRAVELER, TSTF-343, REVISION 1, CONTAINMENT STRUCTURAL INTEGRITY (TAC NO. MD7420)
Dear Mr. Anderson:
By letter dated November 14, 2007, (Agencywide Documents Access and Management System (ADAMS) Accession No. ML073320232) you applied for an amendment to the Duane Arnold Energy Center, Facility Operating License No. DPR-49. The proposed change would have modified the facility technical specifications pertaining to the adoption of TSTF-343, Revision 1, Containment Structural Integrity. Subsequently, by letter dated April 23, 2008, ADAMS Accession No. ML081270233, you withdrew the amendment request.
The Commission has filed the enclosed Notice of Withdrawal of Application for Amendment to Facility Operating License with the Office of the Federal Register for publication. Please contact me at (301) 415-3079 if you have questions.
Sincerely,
/RA/
Karl Feintuch, Project Manager, Plant Licensing Branch III-1 Division of Operating Reactor Licensing Office of Nuclear Reactor Regulation Docket No. 50-331
Enclosure:
Notice of Withdrawal cc w/encl: See next page
ML081350351 OFFICE NRR/LPL3-1/PM NRR/LPL3-1/ LA NRR/EMCB/ BC OGC/NLO NRR/LPL3-1/BC NAME KFeintuch THarris KManoly JBiggins LJames DATE 5/15/08 5/15/08 5/15/08 5/23/08 5/30/08 7590-01-P UNITED STATES NUCLEAR REGULATORY COMMISSION FPL ENERGY DUANE ARNOLD, LLC DOCKET NO. 50-331 NOTICE OF WITHDRAWAL OF APPLICATION FOR AMENDMENT TO FACILITY OPERATING LICENSE NO. DPR-49 The U.S. Nuclear Regulatory Commission (NRC, the Commission) has granted the request of FPL Energy Duane Arnold, LLC (the licensee) to withdraw its November 14, 2007, application for proposed amendment (Agencywide Documents Access and Management System (ADAMS) Accession No. ML073320232) to Facility Operating License No. DPR-49 for the Duane Arnold Energy Center, located in Linn County. .
The proposed amendment would have revised Technical Specification (TS) 5.5.12, Primary Containment Leakage Rate Testing Program, to allow use of the requirements of American Society of Mechanical Engineers (ASME) Boiler and Pressure Vessel Code (the Code),Section XI, Subsection IWE for visual examination of the steel containment. This license amendment request was consistent with NRC-approved Technical Specification Task Force (TSTF) Traveler number TSTF-343, Revision 1, Containment Structural Integrity.
The Commission had previously issued a Notice of Consideration of Issuance of Amendment published in the FEDERAL REGISTER on January 28, 2008 (73 FR 5220).
However, by letter dated April 23, 2008, ADAMS Accession No. ML081270233, the licensee withdrew the proposed change.
For further details with respect to this action, see the application for amendment dated November 14, 2007, and the licensee's letter dated April 23, 2008, which withdrew the application for license amendment. Documents may be examined, and/or copied for a fee, at the NRC=s Public Document Room (PDR), located at One White Flint North, Public File
Area O1 F21, 11555 Rockville Pike (first floor), Rockville, Maryland. Publicly available records will be accessible electronically from the Agencywide Documents Access and Management Systems (ADAMS) Public Electronic Reading Room on the internet at the NRC Web site, http://www.nrc.gov/reading-rm.html. Persons who do not have access to ADAMS or who encounter problems in accessing the documents located in ADAMS should contact the NRC PDR Reference staff by telephone at 1-800-397-4209, or 301-415-4737 or by email to pdr@nrc.gov.
Dated at Rockville, Maryland, this 30th day of May 2008.
FOR THE NUCLEAR REGULATORY COMMISSION
/RA/
Karl Feintuch, Project Manager, Plant Licensing Branch III-1 Division of Operating Reactor Licensing Office of Nuclear Reactor Regulation
Duane Arnold Energy Center cc:
Mr. J. A. Stall Senior Vice President, Nuclear and Chief Mr. D. A. Curtland Nuclear Officer Plant Manager Florida Power & Light Company Duane Arnold Energy Center P. O. Box 14000 3277 DAEC Rd.
Juno Beach, FL 33408-0420 Palo, IA 52324-9785 Mr. M. S. Ross Mr. R. S. Kundalkar Managing Attorney Vice President, Nuclear Technical Svcs.
Florida Power & Light Company Florida Power & Light Company P. O. Box 14000 P. O. Box 14000 Juno Beach, FL 33408-0420 Juno Beach, FL 33408 Ms. Marjan Mashhadi Daniel K. McGhee Senior Attorney Iowa Department of Public Health Florida Power & Light Company Bureau of Radiological Health 801 Pennsylvania Avenue, NW 321 East 12th Street Suite 220 Lucas State Office Building, 5th Floor Washington, DC 20004 Des Moines, IA 50319-0075 Don E. Grissette Chairman, Linn County Vice President, Nuclear Training and Board of Supervisors Performance Improvement 930 1st Street SW Florida Power & Light Company Cedar Rapids, IA 52404 P. O. Box 14000 Juno Beach, FL 33408 Steven R. Catron Manager, Regulatory Affairs Duane Arnold Energy Center 3277 DAEC Road Last revised March 20, 2008 Palo, IA 52324 U. S. Nuclear Regulatory Commission Resident Inspector=s Office Rural Route #1 Palo, IA 52324 Mr. Mano Nazar Senior Vice President and Nuclear Chief Operating Officer Florida Power & Light Company P. O. Box 14000 Juno Beach, FL 33408