EDO Principal Correspondence Control FROM:

DUE': 04/21/08 EDO CONTROL: G20080205 DOC DT: 03/02/08 FINAL REPLY:

William J.

Shack, ACRS TO:

Chairman Klein FOR SIGNATURE OF :

PRI CRC NO: 08-0170

Reyes, EDO DESC:

ROUTING:

Report on the Safety Aspects of the License Renewal Application for the James A. Fitzpatrick Nuclear Power Plant (EDATS: SECY-2008-0174)

DATE: 03/25/08 Reyes Virgilio Mallett Ash Ordaz Cyr/Burns

Cox, RES Pelton, OEDO ACRS File ASSIGNED TO:

NRR CONTACT:

Dyer SPECIAL INSTRUCTIONS OR REMARKS:

Prepare response to ACRS for the signature of the EDO.

Add the Commission and SECY as cc's.

USE SUBJECT LINE IN RESPONSE

~Y~Vtak o~

S6C/~O/

EDATS Number: SECY-2008-0174 Source: SECY Genra Ifomaio Assigned To: NRR OEDO Due Date:.4/21/2008 5:00 PM Other Assignees:

SECY Due Date: NONE

Subject:

Report on the Safety Aspects of the License Renewal Application for the James A. Fitzpatrick Nuclear Power Plant

==

Description:==

CC Routing: NONE ADAMS Accession Numbers - Incoming: NONE Response/Package: NONE OhrInfraio Cross Reference Number: G20080205, LTR-08-0170 Related Task:

File Routing: EDATS Staff Initiated: NO Recurring Item: NO Agency Lesson Learned: NO Roadmap Item: NO Proes Inomtn I

Action Type: Letter Priority: Medium

  • Sensitivity: None Signature Level: EDO Urgency: NO OEDO Concurrence: NO OCM Concurrence: NO OCA Concurrence: NO Special Instructions: Prepare response to the ACRS for the signature of the EDO. Add the Commission and SECY as cc's. USE SUBJECT LINE IN RESPONSE.

I Doumn Infraion Originator Name: William J. Shack, ACRS Originating Organization: ACRS Addressee: Chairman Klein Incoming Task Received: Letter Date of Incoming: 3/20/2008 Document Received by SECY Date: 3/25/2008 Date Response Requested by Originator: NONE Page 1 of I

OFFICE OF THE SECRETARY CORRESPONDENCE CONTROL TICKET Date Printed: Mar 25, 2008 10:56 PAPER NUMBER:

ACTION OFFICE:

LTR-08-0170 EDO LOGGING DATE: 03/24/2008 AUTHOR:

AFFILIATION:

ADDRESSEE:

SUBJECT:

ACTION:

DISTRIBUTION:

LETTER DATE:

ACKNOWLEDGED SPECIAL HANDLING:

William Shack ACRS Dale Klein Report on the safety aspects of the license renewal application for the James A. Fitzpatrick nuclear power plant Appropriate RF 03/20/2008 No NOTES:

FILE LOCATION:

ADAMS DATE DUE:

DATE SIGNED:

EDO -- G20080 2 05

UNITED STATES NUCLEAR REGULATORY COMMISSION

" ".ADVISORY COMMITTEE ON REACTOR SAFEGUARDS WASHINGTON, DC 20555 - 0001 March 20, 2008 The Honorable Dale E. Klein Chairman U.S. Nuclear Regulatory Commission Washington, DC 20555-0001

SUBJECT:

REPORT ON THE SAFETY ASPECTS OF THE LICENSE RENEWAL APPLICATION FOR THE JAMES A. FITZPATRICK NUCLEAR POWER PLANT

Dear Chairman Klein:

During the 5 5 0 th meeting of the Advisory Committee on Reactor Safeguards, March 6-7, 2008, we completed our review of the license renewal application for the James A. FitzPatrick Nuclear Power Plant (JAFNPP) and the final Safety Evaluation Report (SER) prepared by the NRC staff.

Our Plant License Renewal Subcommittee also reviewed this matter during a meeting on September 5, 2007. During these reviews, we had the benefit of discussions with representatives of the NRC staff and the applicant, Entergy Nuclear Operations, Inc., (ENO).

We also had the benefit of the documents referenced. This report fulfills the requirements of 10 CFR 54.25 that the ACRS review and report on all license renewal applications.

CONCLUSION AND RECOMMENDATION

1. The programs established and committed to by the applicant to manage age-related degradation provide reasonable assurance that JAFNPP can be operated in accordance with its current licensing basis for the period of extended operation without undue risk to the health and safety of the public.
2. The ENO application for renewal of the operating license of JAFNPP should be approved.

BACKGROUND AND DISCUSSION JAFNPP is a General Electric boiling water reactor-4 (BWR-4) with a Mark-1 containment. The current power rating of 2536 MWt includes a 4 percent power uprate that was implemented in 1996. ENO requested renewal of the JAFNPP operating license for 20 years beyond the current license term, which expires on October 17, 2014.

In the final SER, the staff documented its review of the license renewal application and other information submitted by ENO and obtained during the audits and inspections conducted at the plant site. The staff reviewed the completeness of the applicant's identification of structures, systems, and components (SSCs) that are within the scope of license renewal; the integrated plant assessment process; the applicant's identification of the plausible aging mechanisms associated with passive, long-lived components; the adequacy of the applicant's Aging Management Programs (AMPs); and the identification and assessment of time-limited aging analyses (TLAAs) requiring review.

In the JAFNPP license renewal application, ENO identified the SSCs that fall within the scope of license renewal and performed an aging management review for these SSCs. Based on this review, the applicant will implement 36 AMPs for license renewal including existing, enhanced, and new programs.

The JAFNPP application either demonstrates consistency with the Generic Aging Lessons Learned (GALL) Report or documents deviations to the specified approaches in this report.

The JAFNPP application includes a significant number of exceptions to the approaches specified in the GALL Report. We reviewed these exceptions and agree with the staff that they are acceptable. Other recent license renewal applications have exhibited a similar trend toward an increasing number of exceptions to the GALL Report. The staff agrees that future updates of the GALL Report should incorporate alternative approaches which are used by the industry and have been approved by the staff. This will reduce the number of exceptions to the GALL Report in future applications and will facilitate the staff review.

The staff conducted license renewal audits and site inspections. The audits verified the appropriateness of the scoping and screening methodology, AMPs, aging management review, and TLAAs. The site inspections verified that the license renewal requirements are appropriately implemented. Based on the audits and inspections, the staff concludes in the SER that the proposed activities will reasonably manage the effects of aging of SSCs identified in the application and that the intended functions of these SSCs will be maintained during the period of extended operation. We agree with this conclusion.

During our meetings with the staff and the applicant, we reviewed the physical condition of the drywell shell of the Mark 1 containment of JAFNPP and the associated AMPs. Aging of the drywell shell and torus of JAFNPP will be managed through the use of the American Society of Mechanical Engineers (ASME) Code Section XI, Subsection IWE Program. This program provides for inspection of primary containment components and the containment yacuum breaker system piping and components. The aging effects are managed by periodic sampling inspections, evaluation of inspection results, and repair of any significant degradation. Drywell monitoring includes periodic boroscopic inspections of the sand cushion area, visual inspection of the interior drywell caulk seal, and inspection of the drywell interior coating system. The JAFNPP drywell design minimizes the potential for water intrusion and includes an alarm system that annunciates in the control room if leakage from the refueling cavity occurs during refueling. The applicant stated that the plant has not experienced occurrences of leakage through the refueling bellows into the area monitored by the air gap leakage detection, system.

The applicant stated, and the NRC inspectors confirmed, that the JAFNPP drywell shell is in good physical condition.

In June 2005, a through-wall leak in the JAFNPP torus shell was identified. The leak was due to a 4.5 inch crack located in the same bay as the high-pressure coolant injection (HPCI) steam exhaust discharge pipe. The root cause of the flaw was vibration fatigue from HPCI steam condensation oscillation loading. Follow-up torus inspections identified similar flaws in two other locations in the same bay. Corrective action included repair of the flaws and the installation of a HPCI steam exhaust sparger assembly that directs steamflow away from the torus shell.

The sparger significantly reduces steam condensation oscillation loads on the torus shell.

Pitting in the wetted area of the torus shell was identified in 1998 when the torus was drained to replace the emergency core cooling system suction strainers. Further inspection of the torus identified pitting in ten areas in four of the 16 torus bays. The pitting occurred at locations that had experienced some degradation of the original coating. The pitted areas have not been re-coated. They are considered as leading indicators of torus shell condition and are being monitored periodically with ultrasonic testing and visual inspection. The staff and the NRC inspection team reviewed the JAFNPP containment inservice inspection program and concluded that ENO's program includes appropriate requirements for continued inspection of the torus, evaluation of observed degradation, and prediction of remaining service life. We concur with this conclusion.

The applicant identified the systems and components requiring TLAAs and reevaluated them for the period of extended operation. The staff concluded that the applicant has provided an adequate list of TLAAs. Further, the staff concluded that in all cases the applicant has met the requirements of the license renewal rule by demonstrating that the TLAAs will remain valid for the period of extended operation, or that the TLAAs have been projected to the end of the period of extended operation, or that the aging effects will be adequately managed for the period of extended operation. We concur with the staff's conclusion that JAFNPP TLAAs have been properly identified and that the required criteria will be met for the period of extended operation..

We agree with the staff that there are no issues related to the matters described in 10 CFR 54.29(a)(1) and (a)(2) that preclude renewal of the operating license for JAFNPP.

The programs established and committed to by ENO provide reasonable assurance that JAFNPP can be operated in accordance with its current licensing basis for the period of extended operation without undue risk to the health and safety of the public. The ENO application for renewal of the operating license for JAFNPP should be approved.

Sincerely, IRA!

William J. Shack, Chairman REFERENCES

1. Letter dated July 31, 2006, from P. Dietrich, Entergy Nuclear Operations, Inc. to U.S.

Nuclear Regulatory Commission, transmitting the Application to Renew the Operating License of James A. FitzPatrick Nuclear Power Plant, (ML062160491).

2. U.S. Nuclear Regulatory Commission, 'Safety Evaluation Report, Related to the License Renewal of James A. FitzPatrick Nuclear Power Plant, " February 2008 (ML080250372).
3. Letter dated June 19, 2007 from N. Le, U.S. Nuclear Regulatory Commission to M. Kansler, Entergy Nuclear Operations, Inc., transmitting the Audit Summary Report for Plant Aging Management Reviews and Programs forthe James A. FitzPatrick Nuclear Power Plant on License Renewal Application, (ML071580049).
4. NRC License Renewal Inspection Report 05000333/2007007, Jarmes A. FitzPatrick Nuclear Power Plant, dated August 2, 2007, (ML072140637).
5. U.S. Nuclear Regulatory Commission, NUREG-1801, Volumes 1 & 2, Revision 1, "Generic Aging Lessons Learned Report," September 2005.

re-coated. They are considered as leading indicators of torus shell condition and are being monitored periodically with ultrasonic testing and visual inspection. The staff and the NRC inspection team reviewed the JAFNPP containment inservice inspection program and concluded that ENO's program includes appropriate requirements for continued inspection of the torus, evaluation of observed degradation, and prediction of remaining service life. We concur with this conclusion.

The applicant identified the systems and components requiring TLAAs and reevaluated them for the period of extended operation. The staff concluded that the applicant has provided an adequate list of TLAAs. Further, the staff concluded that in all cases the applicant has met the requirements of the license renewal rule by demonstrating that the TLAAs will remain valid for the period of extended operation, or that the TLAAs have been projected to the end of the period of extended operation, or that the aging effects will be adequately managed for the period of extended operation. We concur with the staff's conclusion that JAFNPP TLAAs have been properly identified and that the required criteria will be met for the period of extended operation.

We agree with the staff that there are no issues related to the matters described in 10 CFR 54.29(a)(1) and (a)(2) that preclude renewal of the operating license for JAFNPP.

The programs established and committed to by ENO provide reasonable assurance that JAFNPP can be operated in accordance with its current licensing basis for the period of extended operation without undue risk to the health and safety of the public. The ENO application for renewal of the operating license for JAFNPP should be approved.

Sincerely, IRA/

William J. Shack, Chairman REFERENCES

1. Letter dated July 31, 2006, from P. Dietrich, Entergy Nuclear Operations, Inc. to U.S.

Nuclear Regulatory Commission, transmitting the Application to Renew the Operating License of James A., FitzPatrick Nuclear Power Plant, (ML062160491).

2. U.S. Nuclear Regulatory Commission, "Safety Evaluation Report, Related to the License Renewal of James A. FitzPatrick Nuclear Power Plant, " February 2008 (ML080250372).
3. Letter dated June 19, 2007 from N. Le, U.S. Nuclear Regulatory Commission to M. Kansler, Entergy Nuclear Operations, Inc., transmitting the Audit Summary Report for Plant Aging Management Reviews and Programs for the James A. FitzPatrick Nuclear Power Plant on License Renewal Application, (ML071580049).
4. NRC License Renewal Inspection Report 05000333/2007007, James A. FitzPatrick Nuclear Power Plant, dated August 2, 2007, (ML072140637).
5. U.S. Nuclear Regulatory Commission, NUREG-1801, Volumes 1 & 2, Revision 1, "Generic Aging Lessons Learned Report," September 2005.

Distribution: ***See Next Page ADAMS ML080670450 OFFICE ACRS SUNSI ACRS IACRS ACRS NAME MBanerjee MBaneree CSantos FPGiIlespie FPG for WJS DATE 3/18/08 3/18/08 3/18/08 3/20/08 3/20/08 OFFICIAL RECORD COPY Letter To:

The Honorable Dale E. Klein, NRC Chairman From:

William J. Shack, Chairman ACRS

Subject:

REPORT ON THE SAFETY ASPECTS OF THE LICENSE RENEWAL APPLICATION FOR THE JAMES A. FITZPATRICK NUCLEAR POWER PLANT Date:

March 20, 2008 ML080670450 Distribution:

RidsSecyMailCenter RidsNMSSOD RidsNSIROD RidsOIGMailCenter RidsOCAAMailCenter RidsRGN2MailCenter BChamp ABates JPerry SDuraiswamy DPelton Michele Kelton RidsEDOMailCenter RidsNRROD iRidsFSMEOD RidsOCAMailCenter RidsRESOD RidsNROOD RidsOGCMailCenter RidsASLBPMailCenter RidsOPAMailCenter RidsRGN1 MailCenter RidsRGN3MailCenter RidsRGN4MailCenter CSantos MBanerjee SMcKelvin DBessette CHammer LMike HNourbakhsh JFlack ZAbdullahi GShukla CJaegers DFischer PTressler JDelgado HVanderMolen Vickie Murphy Sherry Meador