March 27, 2008 Mr. Peter P. Sena III Site Vice President FirstEnergy Nuclear Operating Company Beaver Valley Power Station Mail Stop A-BV-SEB1 P.O. Box 4, Route 168 Shippingport, PA 15077
SUBJECT:
BEAVER VALLEY POWER STATION, UNIT NO. 2 - ISSUANCE OF AMENDMENT RE: INCORPORATION OF THE RESULTS OF A NEW SPENT FUEL POOL CRITICALITY ANALYSIS (TAC NO. MD2378)
Dear Mr. Sena:
The Commission has issued the enclosed Amendment No. 165 to Facility Operating License No. NPF-73 for the Beaver Valley Power Station, Unit No. 2 (BVPS-2). This amendment consists of changes to the Technical Specifications (TSs) in response to your application dated June 14, 2006, as supplemented by letters dated July 20, July 26, December 21, 2007, and March 11, 2008. By letter dated December 21, 2007, FirstEnergy Nuclear Operating Company withdrew their license amendment request for BVPS-1.
The amendment revises TSs to incorporate the results of a new spent fuel pool (SFP) criticality analysis documented in WCAP-16518-P, "Beaver Valley Unit 2 Spent Fuel Pool Criticality Analysis," Revision 2 for BVPS-2. The new criticality analysis will permit utilization of vacant storage locations dictated by the existing TS storage configurations in the BVPS-2 SFP.
Included in the amendment are two regulatory commitments, which are discussed in the enclosed safety evaluation (SE). The regulatory commitments are enforceable commitments that the Nuclear Regulatory Commission staff is relying upon in approving the amendment.
P. Sena A copy of the related SE is also enclosed. The Notice of Issuance will be included in the Commission's biweekly Federal Register notice.
Sincerely,
/RA/
Nadiyah S. Morgan, Project Manager Plant Licensing Branch I-1 Division of Operating Reactor Licensing Office of Nuclear Reactor Regulation Docket No. 50-412
Enclosures:
- 1. Amendment No. 165 to NPF-73
- 2. SE cc w/encls: See next page
P. Sena A copy of the related SE is also enclosed. The Notice of Issuance will be included in the Commission's biweekly Federal Register notice.
Sincerely,
/RA/
Nadiyah S. Morgan, Project Manager Plant Licensing Branch I-1 Division of Operating Reactor Licensing Office of Nuclear Reactor Regulation Docket No. 50-412
Enclosures:
- 1. Amendment No. 165 to NPF-73
- 2. SE cc w/encls: See next page DISTRIBUTION:
PUBLIC LPLI-1 R/F RidsNrrDorlLpli-1 NMorgan RidsOgcRp GHill(2)
RidsNrrDirsItsb RidsNrrDssSxrb BSingal, DorlDpr RidsRegionIMailCenter SLittle KWood TKolb RidsNrrDirsIolb GLapinksy RidsAcrsAcnw&mMailCenter Package No.: ML080730465 Amendment No.: ML080730476 Tech Spec No.: ML080730482
- Input received. No substantive changes made.
OFFICE LPLI-1/PM LPLI-1/LA IOLB/BC ITBS/BC SRXB/BC OGC LPLI-1/BC NAME NMorgan SLittle NSalgado*
RElliot*
GCranston*
LSubin MKowal DATE 03/13/2008 03/13/2008 01/09/2008 03/24/2008 03/14/2008 03/20/2008 3/27/08 OFFICIAL RECORD COPY
Beaver Valley Power Station, Unit Nos. 1 and 2 cc:
Joseph J. Hagan President and Chief Nuclear Officer FirstEnergy Nuclear Operating Company Mail Stop A-GO-19 76 South Main Street Akron, OH 44308 James H. Lash Senior Vice President of Operations and Chief Operating Officer FirstEnergy Nuclear Operating Company Mail Stop A-GO-14 76 South Main Street Akron, OH 44308 Danny L. Pace Senior Vice President, Fleet Engineering FirstEnergy Nuclear Operating Company Mail Stop A-GO-14 76 South Main Street Akron, OH 44308 Jeannie M. Rinckel Vice President, Fleet Oversight FirstEnergy Nuclear Operating Company Mail Stop A-GO-14 76 South Main Street Akron, OH 44308 David W. Jenkins, Attorney FirstEnergy Corporation Mail Stop A-GO-15 76 South Main Street Akron, OH 44308 Manager, Fleet Licensing FirstEnergy Nuclear Operating Company Mail Stop A-GO-2 76 South Main Street Akron, OH 44308 Ohio EPA-DERR ATTN: Zack A. Clayton P.O. Box 1049 Columbus, OH 43266-0149 Peter P. Sena III Site Vice President FirstEnergy Nuclear Operating Company Beaver Valley Power Station Mail Stop A-BV-SEB1 P.O. Box 4, Route 168 Shippingport, PA 15077 Director, Fleet Regulatory Affairs FirstEnergy Nuclear Operating Company Mail Stop A-GO-2 76 South Main Street Akron, Ohio 44308 Manager, Site Regulatory Compliance FirstEnergy Nuclear Operating Company Beaver Valley Power Station Mail Stop A-BV-A P.O. Box 4, Route 168 Shippingport, PA 15077 Commissioner James R. Lewis West Virginia Division of Labor 749-B, Building No. 6 Capitol Complex Charleston, WV 25305 Director, Utilities Department Public Utilities Commission 180 East Broad Street Columbus, OH 43266-0573 Director, Pennsylvania Emergency Management Agency 2605 Interstate Dr.
Harrisburg, PA 17110-9364
Beaver Valley Power Station, Unit Nos. 1 and 2 (continued) cc:
Dr. Judith Johnsrud Environmental Coalition on Nuclear Power Sierra Club 433 Orlando Avenue State College, PA 16803 Director Bureau of Radiation Protection Pennsylvania Department of Environmental Protection Rachel Carson State Office Building P.O. Box 8469 Harrisburg, PA 17105-8469 Mayor of the Borough of Shippingport P.O. Box 3 Shippingport, PA 15077 Regional Administrator, Region I U.S. Nuclear Regulatory Commission 475 Allendale Road King of Prussia, PA 19406 Resident Inspector U.S. Nuclear Regulatory Commission P.O. Box 298 Shippingport, PA 15077 Ms. Carol OClaire Chief, Radiological Branch Ohio Emergency Management Agency 2855 West Dublin-Granville Road Columbus, OH 43235-2206 Mr. Dan Hill Chief, Radiological Health Program West Virginia Department of Health and Human Resources Capitol & Washington Streets 1 Davis Square Suite 200 Charleston, WV 25305-036
FIRSTENERGY NUCLEAR OPERATING COMPANY FIRSTENERGY NUCLEAR GENERATION CORP.
OHIO EDISON COMPANY THE TOLEDO EDISON COMPANY DOCKET NO. 50-412 BEAVER VALLEY POWER STATION, UNIT 2 AMENDMENT TO FACILITY OPERATING LICENSE Amendment No. 165 License No. NPF-73
- 1.
The Nuclear Regulatory Commission (the Commission) has found that:
A.
The application for amendment by FirstEnergy Nuclear Operating Company, et al. (the licensee), dated June 14, 2006, as supplemented by letters dated July 20, July 26, December 21, 2007, and March 11, 2008, complies with the standards and requirements of the Atomic Energy Act of 1954, as amended (the Act), and the Commission's rules and regulations set forth in 10 CFR Chapter I; B.
The facility will operate in conformity with the application, the provisions of the Act, and the rules and regulations of the Commission; C.
There is reasonable assurance (i) that the activities authorized by this amendment can be conducted without endangering the health and safety of the public, and (ii) that such activities will be conducted in compliance with the Commission's regulations; D.
The issuance of this amendment will not be inimical to the common defense and security or to the health and safety of the public; and E.
The issuance of this amendment is in accordance with 10 CFR Part 51 of the Commission's regulations and all applicable requirements have been satisfied.
- 2.
Accordingly, the license is amended by changes to the Technical Specifications as indicated in the attachment to this license amendment, and paragraph 2.C.(2) of Facility Operating License No. NPF-73 is hereby amended to read as follows:
(2)
Technical Specifications The Technical Specifications contained in Appendix A, as revised through Amendment No. 165, and the Environmental Protection Plan contained in Appendix B, both of which are attached hereto, are hereby incorporated in the license. FENOC shall operate the facility in accordance with the Technical Specifications and the Environmental Protection Plan.
- 3.
This license amendment is effective as of the date of its issuance and shall be implemented within 30 days.
FOR THE NUCLEAR REGULATORY COMMISSION
/RA/
Mark G. Kowal, Chief Plant Licensing Branch I-1 Division of Operating Reactor Licensing Office of Nuclear Reactor Regulation
Attachment:
Changes to the License and Technical Specifications Date of Issuance: March 27, 2008
ATTACHMENT TO LICENSE AMENDMENT NO. 165 FACILITY OPERATING LICENSE NO. NPF-73 DOCKET NO. 50-412 Replace the following page of the Facility Operating License with the attached revised page.
The revised page is identified by amendment number and contains marginal lines indicating the areas of change.
Remove Insert 3a 3a Replace the following pages of the Appendix A Technical Specifications with the attached revised pages. The revised pages are identified by amendment number and contain marginal lines indicating the areas of change.
Remove Insert 3.7.14-1 3.7.14-1 3.7.14-3 3.7.14-3 4.0-2 4.0-2 4.0-3 4.0-3
SAFETY EVALUATION BY THE OFFICE OF NUCLEAR REACTOR REGULATION RELATED TO AMENDMENT NO. 165 TO FACILITY OPERATING LICENSE NO. NPF-73 FIRSTENERGY NUCLEAR OPERATING COMPANY FIRSTENERGY NUCLEAR GENERATION CORP.
OHIO EDISON COMPANY THE TOLEDO EDISON COMPANY BEAVER VALLEY POWER STATION, UNIT NO. 2 DOCKET NO. 50-412
1.0 INTRODUCTION
By application dated June 14, 2006 (Agencywide Documents Access and Management System (ADAMS) Accession No. ML061700101), as supplemented by letters dated July 20 (ADAMS Accession No. ML072050213), July 26 (ADAMS Accession No. ML072110310), December 21, 2007 (ADAMS Accession No. ML073601008), and March 11, 2008 (ADAMS Accession No. ML080730245), the FirstEnergy Nuclear Operating Company (FENOC, licensee), requested changes to the Technical Specifications (TSs) for Beaver Valley Power Station, Unit No. 2 (BVPS-2). The supplements dated July 20, July 26, December 21, 2007, and March 11, 2008, provided additional information that clarified the application, did not expand the scope of the application as originally noticed, and did not change the Nuclear Regulatory Commission (NRC) staff=s original proposed no significant hazards consideration determination as published in the Federal Register on August 15, 2006 (71 FR 46935).
The proposed changes would revise the TS to incorporate the results of a new spent fuel pool (SFP) criticality analysis documented in WCAP-16518-P, "Beaver Valley Unit 2 Spent Fuel Pool Criticality Analysis," Revision 2 for BVPS-2. Specifically, the new criticality analysis will permit utilization of vacant storage locations dictated by the existing TS storage configurations in the BVPS-2 SFP.
By letter dated December 21, 2007, the licensee withdrew their license amendment request (LAR) for BVPS-1 contained in the original application. In addition to reviewing all submitted documents, the NRC staff audited licensee information at Westinghouse Electric Company, LLC (WEC) locations in Monroeville, PA, and in Rockville, MD. Information from those audits necessary to reach a regulatory decision was submitted by letter dated March 11, 2008.
Currently, BVPS-2 TS 3.7.14 contains Table 3.7.14-1B, SFP Storage. BVPS-2 SFP is divided into three Regions, which are identified in Table 3.7.14-1B. The requested changes for BVPS-2 will create four storage configurations. Each storage configuration has a geometric
arrangement which must be maintained so that the SFP criticality analysis remains valid. The storage configurations may be interspersed with each other throughout the SFP, provided geometric interface requirements are met. Each storage configuration has a burnup/enrichment requirement that must be met for a fuel assembly to be stored in that configuration. One storage configuration takes credit for the natural decay of 241Pu in the depleted fuel. Another storage configuration takes credit for the presence of integral burnable poisons in fresh fuel. To implement the new storage configurations, Table 3.7.14-1B will be revised to provide the burnup/enrichment requirement for one storage configuration. The 3.7.14 Limiting Condition for Operation (LCO) will be revised to state that, for BVPS-2, fuel assemblies not meeting the requirements of Table 3.7.14-1B must be stored in accordance with requirements in the Design Features TS 4.3.1.1. Rather than put all of the details in Design Features TS 4.3.1.1, Westinghouse Commercial Atomic Power (WCAP)-16518-P, Revision 2, will be incorporated by reference.
The SFP criticality analysis was performed for the licensee by WEC as WCAP-16518-P.
Revision 1 of WCAP-16518 was submitted by the licensee as Enclosure 2 to Reference 1.
Revision 2 of WCAP-16518 was submitted by the licensee as Enclosure 1 to Reference 3.
2.0 REGULATORY EVALUATION
The revised BVPS-2 SFP criticality analysis takes credit for soluble boron. Therefore, the regulatory requirement for the BVPS-2 SFP k-effective (keff) is to remain below 1.0, at a 95 percent probability, 95 percent confidence level, if flooded with unborated water and below 0.95, at a 95 percent probability, 95 percent confidence level, if flooded with borated water. The revised BVPS-2 SFP criticality analysis uses an analytic acceptance criterion of keff <0.995 if flooded with unborated water, reserving 0.005 keff analytical margin to the regulatory requirement. The revised BVPS-2 SFP criticality analysis does not explicitly state a specific analytic acceptance criterion if flooded with borated water. As performed in the licensees analysis, the borated water condition should also reserve 0.005 keff analytical margin to the regulatory requirement.
The revised BVPS-2 SFP criticality analysis requires specific geometric arrangements of fuel assemblies within the SFP to meet the 10 CFR 50.68(b)(4) regulation. Therefore, there is a regulatory requirement for those geometric arrangements to be captured in the Design Features section of the TS. This is being accomplished by incorporating Revision 2 of WCAP-16518 into the Design Features section of the BVPS TS.
10 CFR Part 50 Appendix A Criterion 62 requires, ACriticality in the fuel storage and handling system shall be prevented by physical systems or processes, preferably by use of geometrically safe configurations.@
10 CFR Part 50.68(b)(1) requires, APlant procedures shall prohibit the handling and storage at any one time of more fuel assemblies than have been determined to be safely subcritical under the most adverse moderation conditions feasible by unborated water.@
10 CFR 50.68(b)(4) requires, AIf no credit for soluble boron is taken, the k-effective of the spent fuel storage racks loaded with fuel of the maximum fuel assembly reactivity must not exceed 0.95, at a 95 percent probability, 95 percent confidence level, if flooded with
unborated water. If credit is taken for soluble boron, the k-effective of the spent fuel storage racks loaded with fuel of the maximum fuel assembly reactivity must not exceed 0.95, at a 95 percent probability, 95 percent confidence level, if flooded with borated water, and the k-effective must remain below 1.0 (subcritical), at a 95 percent probability, 95 percent confidence level, if flooded with unborated water.@
10 CFR 50.36(c)(4) requires, ADesign features. Design features to be included are those features of the facility such as materials of construction and geometric arrangements, which, if altered or modified, would have a significant effect on safety and are not covered in categories described in paragraphs (c) (1), (2), and (3) of this section.@
The current BVPS-2 TS 3.7.14 divides the fuel into three Regions. The current BVPS-2 TS lack specificity with respect to the description of each Region and it contains no description of any interface between the Regions.
The proposed change replaces the three Regions with four storage configurations. Three of the storage configurations are 2x2 arrays of storage cells and the fourth is a 3x3 array of storage cells. One 2x2 array is identified in TS 3.7.14, while the others are reached through a redirection to TS Design Features Section 4.3.1.1. In TS 4.3.1.1, the details of the storage configurations are reached through incorporation of Revision 2 of WCAP-16518 into the TS.
This is consistent with NUREG-1431 and, therefore, is acceptable.
The area of human factors deals with programs, procedures, training, and plant design features related to operator performance during normal and accident conditions. The NRCs acceptance criteria for human factors are based on the following regulatory requirements and guidance:
Appendix A to Title 10 of the Code of Federal Regulations (10 CFR) Part 50, General Design Criteria (GDC), Criterion 19 10 CFR 50.120, Training and qualification of nuclear power plant personnel NUREG-1764, Guidance for the Review of Changes to Human Actions NUREG-0711, Human Factors Engineering Program Review Model, Revision 2 NUREG-0800, Standard Review Plan, Revision 1
3.0 TECHNICAL EVALUATION
3.1 Methodology There is not a generic methodology for performing SFP criticality analyses. By letter dated July 27, 2001, the NRC staff concluded that the methodology of WCAP-14416 can no longer be relied upon as approved methodology by the NRC staff or the licensees (Reference 9). In its letter, the NRC stated, For future licensing actions, licensees will need to submit plant-specific criticality calculations for spent fuel pool configurations that include technically supported margins.
The NRC staff issued an internal memorandum on August 19, 1998, containing guidance for performing the review of SFP criticality analysis (Reference 6). This memorandum is known colloquially as the Kopp Letter, after the author. While the Kopp Letter does not specify a methodology, it does provide some guidance on more salient aspects of a criticality analysis.
The guidance is germane to boiling-water reactors and pressurized-water reactor (PWR),
borated and unborated. The Kopp Letter has been used as a touchstone for virtually every PWR SFP criticality analysis, including this BVPS-2 analysis.
WCAP-16518 Section 1.1 states, The methodology used in this analysis for soluble boron credit is analogous to that of Reference 1 [R. E. Ginna SFP criticality Safety Evaluation Report (SER), Reference 7 herein] and employs analysis criteria consistent with those cited in the Safety Evaluation by the Office of Nuclear Reactor Regulation, Reference 2 [SER to WCAP-14416-NP, Reference 8 herein]. Reference 1 was reviewed and approved by the U.S.
Nuclear Regulatory Commission (NRC). However, there are key tenants of those references that were not performed for the BVPS-2 analysis. Additionally, there were several unique modeling aspects from the Ginna analysis that were not replicated in the BVPS-2 analysis.
Therefore, the NRC staff does not believe that there is ample fidelity between those references and what was done for the BVPS-2 analysis for them to be used as a description of the BVPS-2 soluble boron credit methodology.
During the audit on January 10, 2008, WEC provided information on how the BVPS-2 soluble boron credit analysis was performed. That information was reviewed by the NRC staff in additional information obtained from the WEC audit at the Rockville office, which is documented in Reference 5. The NRC staff evaluation of that methodology is located in Section 3.6.
WCAP-16518 Section 1.2 states, The design criteria are consistent with General Design Criterion (GDC) 62, Reference 4 [10 CFR Part 50 Appendix A Reference 10 herein], and NRC guidance given in Reference 5 [Kopp Letter, Reference 6 herein]. Section 1.3 describes the analysis methods including a description of the computer codes used to perform the criticality safety analysis. The guidance in the Kopp Letter can be summarized as a determination of the biases and uncertainties for the parameters affecting reactivity in the SFP, and apply them in the conservative direction. The guidance allows for the statistical combination of uncertainties, provided they are independent.
3.2 Computer Code Validation The analysis in WCAP-16518 employs: (1) SCALE-PC, a personal computer version of the SCALE-4.4a code system, with the updated SCALE-4.4a version of the 44 group Evaluated Nuclear Data File, Version 5 (ENDF/B-V) neutron cross section library, and (2) the two-dimensional Discrete Integral Transport (DIT) code with an Evaluated Nuclear Data File, Version 6 (ENDF/B-VI) neutron cross section library. SCALE-PC was used for criticality calculations. SCALE-PC, used in both the benchmarking and the fuel assembly storage configurations, includes the control module CSAS25 and the following functional modules:
BONAMI, NITAWL-II, and KENO V.a (KENO). The DIT code is used for simulation of in-reactor fuel assembly depletion.
Validation of SCALE-PC for purposes of fuel storage rack analyses is based on the analysis of 30 selected critical experiments from two experimental programs: 19 from the Babcock & Wilcox (B&W) experiments in support of Close Proximity Storage of Power Reactor Fuel and 11 from
the Pacific Northwest Laboratory (PNL) Program in support of the design of Fuel Shipping and Storage Configurations.
The experiments used for validation are the same experiments WEC has used to validate criticality codes in the past. The method used for validating the codes is the same as used in the past. There is a slight difference in results as previous analysis used SCALE-4.3, but the method of validation is the same. As documented in the Prairie Island (PI) safety evaluation (SE) and Vogtle SE, the NRC staff has previously accepted those experiments and methods.
In addition to using the SCALE-PC code to perform the criticality analyses, the licensee employed the DIT code to perform the fuel depletions used in the analysis. DIT performs a heterogeneous multi-group transport calculation for an explicit representation of a fuel assembly to determine the isotopic composition of the spent fuel as a function of fuel burnup and initial feed enrichment. The DIT code and its cross section set have been used in the design of reload cores and extensively benchmarked against operating reactor history and test data. As documented in the PI SE and Vogtle SE, the NRC staff has previously accepted the use of DIT as the in-reactor depletion code for use in criticality analysis.
3.3 SFP Description of the SFP WCAP-16518, Section 2.2 provides a description of the BVPS-2 SFP. The BVPS-2 SFP has 17 rack modules, each with 64 (8x8) cell locations for a total of 1088 storage cells. Rack modules are separated from each other by a 1.125 inch gap. Rack modules are located 6.5 inches from the north wall and 9.375 inches from the south wall, 36.4375 inches from the west wall, and 14.75 inches from the east wall of the SFP. They are also located 4.0624 inches from the transfer canal wall on the south side. Figure 2-1 of WCAP-16518 shows the SFP and the storage rack modules. Table 2-1 of WCAP-16518 summarizes the overall geometry data for the BVPS-2 SFP.
WCAP-16518, Section 2.3 provides a description of the BVPS-2 SFP individual storage cells.
BVPS-2 SFP storage cells are centered on a pitch of 10.4375 +/- 0.0278 inches. Each storage cell consists of an inner stainless steel canister, which has a nominal inside dimension of 8.9375
+/- 0.0469 inches and is 0.090 +/- 0.010-inches thick. On the outside of each cell wall is a Boraflex poison panel which is held in place and is centered on the surface of the stainless steel canister by an outer stainless steel sheathing panel. The sheathing contacts the outside face of the Boraflex poison panel. The sheathing surfaces of two adjacent storage cells are separated only by pool water. The dimensions of the Boraflex poison panel are 7.5 +/- 0.0625 inches in width by 0.078-inch in thickness. The sheathing panels are included as 0.0293 +/- 0.005 inch in thickness and are located at the outside surface of the nominal Boraflex poison panel position. Due to Boraflex degradation, its reactivity worth cannot be determined. Therefore, the licensees analysis appropriately does not credit the neutron absorbing capabilities of Boraflex. The licensees analysis replaces the Boraflex with SFP water.
SFP Mechanical Uncertainties The material and configuration of the SFP racks contributes to the reactivity. The material provides a fixed neutron absorber and the configuration controls the fuel assembly spacing.
The NRC staff has provided guidance on how these uncertainties should be treated in the Kopp Letter.
The licensees SFP analysis determined a separate uncertainty for the tolerances associated with each of the following parameters: cell pitch, cell wall thickness, cell internal dimension, and the Boraflex wrapper thickness. An uncertainty was also determined for the assembly positioning within the cells. The uncertainty for each parameter was determined by comparison of a nominal case in which all parameters were defined at their nominal values to a case where parameter i was decreased by the manufacturing tolerance. The keff uncertainty for parameter i is equal to the keff nominal, after being increased by the KENO nominal case standard deviation, (nominal), minus keff i, after being decreased by i, where keff i and i, are the keff and KENO case standard deviation with parameter i perturbed. In response to the request for additional information (RAI) concerning the sensitivity of various aspects of the analysis, WEC presented a discussion of the sensitivity of the uncertainties. That information indicated that decreasing all of the parameters by their tolerance may not have always resulted in the largest increase in keff.
Increasing the cell internal dimension actually shows a larger increase in keff rather than when decreased. The convergence and case standard deviation of a KENO criticality problem is sensitive to the following KENO input parameters: (1) the number of neutron histories per cycle, (2) the number of cycles skipped before averaging, (3) the total number of cycles. By adjusting these KENO parameters WEC would be able to reduce the KENO case standard deviation and thereby its contribution to the keff uncertainty for each parameter. This was introduced during the Monroeville Audit and was reviewed in detail during the Rockville Audit. The NRC staff has audited the WEC calculation that re-evaluated the bias and uncertainties. That re-evaluation included two main differences from the submitted analysis. First, it increased rather than decreased the cell internal dimension; this resulted in a larger reactivity uncertainty for that parameter. Second, it increased the number of neutron histories per cycle, the number of cycles skipped before averaging, and the total number of cycles in each KENO case; this increased computational rigor resulted in smaller KENO case standard deviations for each case, which in turn, result in smaller reactivity uncertainties for other parameters. The re-evaluation showed that when the uncertainties are statistically combined through a root mean sum of the squares (RMSS) method, the non-conservatism associated with the first difference is accommodated by the conservatism associated with the second. Based on that audit, the NRC staff has reasonable assurance that sufficient margin can be shown to accommodate the non-conservatism of not identifying the limiting reactivity uncertainty associated with the cell internal dimension.
SFP Temperature Bias The NRC guidance provided in the Kopp Letter states that the criticality analysis should be done at the temperature corresponding to the highest reactivity. If the SFP has a positive moderator temperature coefficient (MTC), the temperature corresponding to the highest reactivity would be the highest allowed operating temperature. Rather than determining the most reactive temperature and performing all of the analyses at that temperature, WCAP-16518 performed the bulk of the analyses at a nominal temperature and then determined a temperature bias. In Reference 1, a separate temperature bias for each configuration is shown. The temperature bias is indicated as being calculated at a particular enrichment/burnup combination, i.e. 4.00 w/o and 25 gigawatt day per metric ton of uranium (GWD/MTU). There is otherwise no information given on how the value was determined. The licensee was asked to describe how the temperature bias was determined and justify the use of the particular enrichment/burnup
combination. In response to the RAI (Reference 2), the licensee described how the temperature bias was calculated. The temperature bias was set equal to the keff nominal at 50 degrees Fahrenheit (°F), after being increased by the nominal at 50 °F, minus the keff nominal at 185 °F, after being decreased by the nominal at 185 °F. The licensees analysis uses four burnup/enrichment combinations to establish third order burnup/enrichment polynomials which determine SFP storage requirements. Therefore, calculating the temperature bias at one burnup/enrichment combination represents a typical rather than a limiting or bounding value. The NRC staff considers the use of a typical rather than a limiting or bounding value to be non-conservative.
As the WCAP-16518 calculated values vary between 0.01 and 0.001 keff, and as a bias, it is applied directly rather than convoluted through an RMSS combination; the temperature bias also has the potential to significantly impact the end result.
During the audit at the Rockville office, the NRC staff reviewed information provided to justify using the typical temperature bias calculated in WCAP-16518. The NRC staff found that justification was insufficient and requested the licensee to provide the results of analysis which ensure the maximum temperature bias has been determined for each storage configuration.
The result of that analysis is provided in Reference 5. As a result of that analysis, the temperature bias increased for two of the storage configurations. The temperature bias for the 3x3 storage configuration increased by 0.00025 keff. The temperature bias for the 1-out-of-4 3.85 w/o Fresh with IFBA storage configuration increased by 0.00090 keff. These increases reduce the reserved 0.005 keff analytical margin directly. The temperature bias for the other two storage configurations was unchanged.
3.4 Fuel Assembly Selection of Bounding Fuel Assembly Design BVPS-2 is using or has used the WEC 17 x 17 Standard, Vantage 5H, VANTAGE+, and the robust fuel assembly (RFA/RFA)-2 fuel assembly designs. The licensees analysis used the Standard fuel assembly design to model all of the fuel in the BVPS-2 SFP. In the Kopp Letter, the NRC indicates the SFP criticality analysis should consider such fuel assembly mechanical design parameters as cladding material and thickness, pellet and rod diameter, and structural items that are an integral part of the assembly i.e. spacer grids. In response to a request to justify the use of the 17x17 Standard fuel assembly design to model all of the fuel, the licensee stated, Westinghouse fuel products with a 0.3740-inch diameter fuel pin [] differ in their grid, nozzle, and other structural material designs. Since these structural materials are not credited in the criticality analysis, these assembly designs are neutronically equivalent. One other minor difference between the Standard and other designs is the diameter of the instrumentation tube in the center of the assembly, which will have little impact on the analysis, typically within the Monte Carlo uncertainty (statistically insignificant). Therefore, the Standard assembly design conservatively bounds all other designs. Furthermore, nominal fuel pin and clad dimensions are considered for this analysis, since any manufacturing tolerance in the fuel pin and clad dimensions, due to its small magnitude, will result in an insignificant neutronic impact, again typically within the Monte Carlo calculation uncertainty (statistically insignificant) or are bounded by other conservatisms.
This treatment of the fuel assembly design differences is different than that indicated in the NRC staffs guidance. To validate this methodology, the NRC staff performed several actions: (1) investigated the assumption to not model any fuel assembly grids, (2) compared the other fuel
assembly mechanical parameters, and (3) evaluated conservatisms present in the licensees analysis.
The licensees analysis assumes not modeling the spacer grids or mixing grids is conservative, and therefore, the differences in number, size, and composition of the grids are immaterial. The spacer grids or mixing grids will have a non-zero absorption cross-section. However, these grids are made of the same material as the fuel cladding and, therefore, will have an overall low absorption cross-section. Not modeling the grids effectively increases the amount of over-moderation in an already over-moderated SFP. The increase in over-moderation must be balanced against the absorption by the grids. The licensee was asked to provide information to validate this assumption. WEC provided the results of several case studies which were considered during both audits. Those case studies indicate that in unborated condition there is some conservatism in not modeling the grids. Those case studies also indicate that in some scenarios, which involve soluble boron credit, not modeling the grids may actually be non-conservative. While those case studies were not exhaustive nor were they docketed, the NRC staff finds there is reasonable assurance to conclude that for the BVPS-2 analysis documented in WCAP-16518, it is acceptable to not model the grids for the unborated condition.
The presence of sufficient margin in the soluble boron crediting portion of the analysis to accommodate the potential small non-conservatism in the unborated scenarios when not modeling the grids is discussed in Section 3.6.
The NRC staff reviewed WCAP-12610-P-A, VANTAGE+ Fuel Assembly Reference Core Report, (Reference 11), BVPS-2 Updated Final Safety Analysis Report (UFSAR) Revision 16 (Reference 12), and WEC letter LTR-NRC-02-55, Fuel Criterion Evaluation Process (FCEP)
Notification of the RFA-2 Design, Revision 1, (Proprietary), (Reference 13). While WCAP-12610-P-A indicates there is more than one rod diameter option for the 17x17 VANTAGE product, the BVPS-2 UFSAR indicates they only have the 0.3740-inch diameter fuel pin. Since the NRC staff has determined that it is acceptable for the BVPS-2 analysis documented in WCAP-16518 to not model the grids, and the review of References 11, 12, and 13 indicate the fuel assemblies are otherwise sufficiently similar, the NRC staff accepts the use of the WEC Standard fuel assembly as the reference assembly.
Fuel Assembly Mechanical Tolerances The analysis in WCAP-16518 determined a reactivity uncertainty for fuel enrichment, but not for any other fuel assembly manufacturing tolerance. This treatment of the fuel assembly manufacturing tolerances is different than that indicated in the NRC staffs guidance.
The analysis used two methods for calculating the enrichment uncertainty. One method uses a polynomial fit to calculate values based on enrichment to determine the reactivity worth of the tolerance at the middle of the curve. This method represents a typical rather than a limiting or bounding value. The NRC staff considers the use of a typical rather than a limiting or bounding value to be non-conservative. The other method is to add the uncertainty to the maximum fresh enrichment and compare that reactivity to a nominal case. This method appears to discount the effect of the uncertainty in the more numerous, albeit, depleted fuel assemblies. Since both methods are used for storage configurations allowing fresh fuel assemblies, it is unclear which method would produce the limiting uncertainty.
The analysis in WCAP-16518 provides no discussion of why the other fuel assembly mechanical tolerances are not addressed. It does state that pellet dishing and chamfering is not modeled, and a maximum Theoretical Density (TD) is used. Subsequent discussions with the licensee and WEC revealed that not modeling pellet dishing and chamfering, while using a maximum TD, was intended to provide sufficient margin such that not addressing the other fuel assembly tolerances is accommodated.
In response to RAIs and during the audits, as documented in Reference 5, the licensee provided additional information regarding the treatment of the fuel assembly manufacturing tolerances. The additional information indicates that the difference between the limiting and typical enrichment uncertainties used in the WCAP-16518 should reasonably be bounded by 0.001 keff. The additional information indicates that the uncertainties associated with the other fuel assembly manufacturing tolerances would be on the order of 0.001 keff, each. Since the uncertainties are statistically combined through an RMSS method, their individual impact is diluted. The additional information determined the margin associated with the TD used in the analysis. For this analysis, that margin is sufficient to accommodate the non-conservatisms in the treatment of the fuel assembly mechanical tolerances.
The licensee=s analysis does not determine a reactivity uncertainty for integral burnable poisons.
The licensee=s analysis does model integral burnable poisons for one storage configuration.
Therefore, it does take credit for integral burnable poisons. When integral burnable poisons are modeled, they are only modeled for fresh fuel and the integral burnable poison loading is reduced by amounts the staff has previously accepted as appropriate to account for manufacturing and calculation uncertainties. Therefore, the treatment of the integral burnable poisons is acceptable.
3.5 Spent Fuel Characterization For the SFP criticality analysis, the fuel must be characterized appropriately. Characterization of fresh fuel is relatively straight forward. It is based primarily on 235U enrichment and various manufacturing tolerances. The manufacturing tolerances are typically manifested as uncertainties, as discussed above, or are bounded by values used in the analysis. These tolerances and bounding values would also carry through to the spent fuel, the standard practice has been to treat the uncertainties as unaffected by the depletion. The characterization of spent fuel is more problematic. Its characterization is based on the specifics of its initial conditions and its operational history in the reactor. The characterization has three main areas:
(1) a burnup uncertainty, (2) the axial apportionment of the burnup, and (3) the core operation that achieved that burnup.
Burnup uncertainty In the Kopp Letter, the NRC staff provided guidance for determining the burnup uncertainty: A reactivity uncertainty due to uncertainty in the fuel depletion calculations should be developed and combined with other calculational uncertainties. In the absence of any other determination of the depletion uncertainty, an uncertainty equal to 5 percent of the reactivity decrement to the burnup of interest is an acceptable assumption. The 5 percent reactivity decrement has been used throughout the industry since the issuance of the Kopp Letter. Rather than use the 5 percent reactivity decrement as the burnup uncertainty, the WCAP-16518 analysis used a 5 percent decrease in the burnup of interest. WCAP-16518 does not identify the deviation from
the NRC staff guidance, nor did it provide any justification for its method of calculating the uncertainty. From RAI responses concerning the burnup uncertainty (Reference 2), the NRC staff was able to discern the deviation from the NRC staff guidance. However, those RAI responses did not include a justification for the method used. WEC presented a discussion of the method used for the WCAP-16518 method of calculating the uncertainty during the audit at the Monroeville office. The PI SFP criticality LAR also attempted to use a 5 percent decrease in burnup as the burnup uncertainty. After receiving RAI responses for the Prairie Island LAR, the NRC staff concluded in Reference 16 that, The licensees original burnup uncertainty analysis was based on an unapproved methodology and did not contain sufficient information to demonstrate NRC regulatory and safety criteria were satisfied. During the audit at the Rockville office, the NRC staff reviewed information concerning the use of an uncertainty of a 5 percent decrease in the burnup of interest rather than an uncertainty equal to 5 percent of the reactivity decrement to the burnup of interest. The NRC staff has found that the information was insufficient to justify the use of 5 percent decrease in the burnup of interest as the burnup uncertainty. Any deviation from the staff guidance must include, but not be limited to, an extensive comparison of the predicted isotopic concentrations to actual measured isotopic concentrations. Additionally, the burnup uncertainty should not be diminished without considering other impacts of the burnup crediting such as the practice of not recalculating the reactivity uncertainties with burnup present.
In response, the licensee recalculated the burnup uncertainty in accordance with the NRC staff guidance in the Kopp Letter. The results are provided in Reference 5. The burnup uncertainty for each storage configuration has increased significantly. While the burnup uncertainty is included in the statistical combination through an RMSS method, the burnup uncertainty is the largest uncertainty and the increase is significant, making a significant impact on the final uncertainty value. Post RMSS combination of the reserved 0.005 keff analytical margin was reduced by 0.00222 keff for the All-Cell storage configuration, by 0.00303 keff for the 3x3 storage configuration, by 0.00291 keff for the 1-out-of-4 5.0 w/o at 15GWD/MTU storage configuration, and by 0.00278 keff for the 1-out-of-4 3.85 w/o Fresh with IFBA storage configuration.
Axial Apportionment or Burnup Profile Another important aspect of fuel characterization is the selection of the burnup profile. At the beginning of life, a PWR fuel assembly will be exposed to a near-cosine axial-shaped flux, which will deplete fuel near the axial center at a greater rate than at the ends. As the reactor continues to operate, the cosine flux shape will flatten because of the fuel depletion and fission-product buildup that occurs near the center. Near the fuel assembly ends, burnup is suppressed due to leakage. If a uniform axial burnup profile is assumed, then the burnup at the ends is over predicted. Analysis has shown that this results in an under prediction of keff; generally the under prediction becomes larger as burnup increases. This is what is known as the >end effect.= Judicious selection of the axial burnup profile is necessary to ensure keff is not under predicted due to the end effect. NUREG/CR-6801, ARecommendations for Addressing Axial Burnup in PWR Burnup Credit Analysis,@ (Reference 15) provides insight for selecting an appropriate axial burnup profile.
With respect to the burnup axial profile, WCAP-16518 used what it characterized as the limiting axial burnup profile from NUREG/CR-6801. As stated in WCAP-16518, Input to this analysis is based on the limiting axial burnup profile data provided in the Department of Energy (DOE)
Topical Report, as documented in Reference 20. Reference 20 in WCAP-16518 is NUREG/CR-6801. NUREG/CR-6801 builds on previous work done in DOE Topical Report DOE/RW-0472, Topical Report on Actinide-Only Burnup Credit for PWR Spent Nuclear Fuel Packages (Reference 17). However, NUREG/CR-6801 does not identify a single 'limiting burnup profile.' NUREG/CR-6801 identifies a 'limiting burnup profile' for each of the twelve specified burnup intervals. Some of the NUREG/CR-6801 profiles are different from the twelve profiles identified in the DOE Topical Report. These limiting profiles are selected from approximately 3200 profiles submitted from a variety of plants representing the U.S. PWR fleet through the early 1990s. The profiles from higher burnup intervals are generally non-conservative when used at lower burnups. NUREG/CR-6801 recognizes the calculational convenience of identifying three larger burnup intervals, each with a 'limiting burnup profile' taken from the twelve. NUREG/CR-6801 did not change those profiles. WCAP-16518 used the profile identified as limiting for burnup greater than 30GWD/MTU, for all burnup levels.
NUREG/CR-6801 indicates this profile is approximately 2.5% non-conservative at burnups of 25 GWD/MTU and 15 GWD/MTU. WCAP-16518 uses calculations performed at these burnup levels to establish the SFP storage configuration loading curves. Non-conservatism in the cases run at burnups of 25 GWD/MTU and 15 GWD/MTU would result in non-conservatism in the loading curves. Also, NUREG/CR-6801 indicates there should be more than 10 axial nodes, whereas the WCAP-16518 analysis used 4. The responses to RAIs asking for justification for using the single profile and nodalization were insufficient.
During the audit at the Monroeville office, WEC made a qualitative argument that the profile identified as limiting for burnup greater than 30 GWD/MTU in NUREG/CR-6801 is a B&W profile which is a statistical outlier, much worse than the limiting WEC profile. This reasoning is consistent with NUREG/CR-6801. The NUREG/CR-6801 focus is identifying limiting profiles for storage/transportation cask criticality analysis. The limiting profiles are selected to virtually eliminate the possibility that a more limiting profile could be found in actuality. Given the broad nature of the limiting profile, it is possible that a site specific evaluation would identify conservatism associated with those profiles or less restrictive profiles that could be used. The information reviewed during the audit at the Rockville office indicates the burnup profile used in WCAP-16518 provides approximately 0.015 keff of margin at burnups 30 GWD/MTU.
However, the information did not address the apparent non-conservatism of using that profile at burnups of 25 GWD/MTU and 15 GWD/MTU. Reference 5 contains the results of a BVPS site specific analysis which evaluated limiting BVPS-2 enrichment loadings with BVPS-2 burnup profiles against the profile used in WCAP-16518. That information indicates that for the 4.0 w/o enrichment cases run at 25 GWD/MTU and 15 GWD/MTU, there is some margin. However, that information also indicates that for a typical 3.6 w/o base loading with 1.0 w/o axial blankets, there is essentially no margin at 15 GWD/MTU with some margin at 20 GWD/MTU. If the information is extrapolated to the WCAP-16518 3.0 w/o enrichment cases run at 25 GWD/MTU and 15 GWD/MTU used to determine the SFP loading curves, the margin at 25 GWD/MTU likely disappears and the margin at 15 GWD/MTU becomes negative. The licensee has asserted, in Reference 5, that it does not currently have any spent fuel that would meet this scenario. To preclude the non-conservative implications of any future acquisition of such fuel, the licensee has stipulated certain regulatory commitments, as stated in Section 4.0.
In Reference 5, the licensee has affirmed that benchmark calculations were performed which demonstrate four axial zones are sufficient to adequately capture the end effect. Those calculations were not part of the audits. Since the NRC staff has accepted the use of four axial zones in previous analysis, the NRC staff considers that the licensees affirmation provides reasonable assurance that the four axial zones are sufficient to adequately capture the end effect for BVPS-2.
Burnup History/Core Operating Parameters NUREG/CR-6665, Review and Prioritization of Technical Issues Related to Burnup Credit for LWR Fuel, (Reference 14) provides some discussion on the treatment of depletion analysis parameters that determine how the burnup was achieved. While NUREG/CR-6665 is focused on criticality analysis in storage and transportation casks, the basic principals with respect to the depletion analysis apply generically to SFPs, since the phenomena occur in the reactor as the fuel is being used. The results have some translation to SFP criticality analyses, especially when the discussion includes the effect in an infinite lattice analysis, similar to that performed for SFP analyzes. The basic premise is to select parameters that maximize the Doppler broadening/spectral hardening of the neutron field resulting in maximum 241Pu production.
NUREG/CR-6665 discusses six parameters affecting the depletion analysis: (1) fuel temperature, (2) moderator temperature, (3) soluble boron, (4) specific power and operating history, (5) fixed burnable poisons, and (6) integral burnable poisons. While the mechanism for each is different, the effect is similar: Doppler broadening/spectral hardening of the neutron field resulting in maximum 241Pu production. NUREG/CR-6665 provides an estimate of the reactivity worth of these parameters. The largest effect appears to be due to moderator temperature. NUREG/CR-6665 approximates the moderator temperature effect, in an infinite lattice of high burnup fuel, to be 90 percent millirho per degree Kelvin (pcm/EK). Thus, a 10 EF change in moderator temperature used in the depletion analysis would result in 0.005 keff. The effects of each core operating parameter have a burnup or time dependency. At a moderate burnup, the moderator effect would be significantly reduced from that cited.
With the exception of boron concentration, the WCAP-16518 analysis used typical rather than limiting values for the in-core depletion portion of the analysis. In response to RAIs and during the audits, the licensee indicated that the analysis contains sufficient margin based on the burnup profile to accommodate the use of typical rather than limiting values in the fuel depletion portion of the analysis. As discussed in the previous section concerning the burnup profile used in WCAP-16518, it is reasonable that there is approximately 0.015 keff margin at burnups 30GWD/MTU. This margin is sufficient to accommodate the use of typical core parameters for burnups 30GWD/MTU. Following the audit at the Rockville office, the NRC staff requested a site-specific analysis to determine whether or not there was sufficient margin in the burnup profile to accommodate the use of typical core parameters for burnups below 30GWD/MTU.
Reference 5 contains the results of that BVPS-2 site specific analysis. The next five paragraphs discuss whether the burnup profile used in WCAP-16518 provides sufficient margin to accommodate the use of typical core operating parameters for burnups below 30 GWD/MTU.
As noted previously, the site-specific analysis showed that there are possible scenarios where the burnup profile has negative margin. The regulatory commitments should prevent those scenarios from occurring in the BVPS-2 SFP and are not reconsidered here.
For fuel and moderator temperatures, NUREG/CR-6665 recommends using the maximum operating temperatures to maximize 241Pu production. The WCAP-16518 analysis used
temperatures below the maximum at which the plant could be operated as indicated by the licensees UFSAR. The NRC staff considers the use of typical rather limiting or bounding values to be non-conservative. The site-specific analysis in Reference 5 was performed at the maximum fuel and moderator temperatures for BVPS-2. Therefore, the moderator and fuel temperature used is acceptable.
For boron concentration, NUREG/CR-6665 recommends using a conservative cycle average boron concentration. The licensee=s analysis used a conservative boron concentration throughout the depletion of the fuel assemblies, when compared to the licensees UFSAR.
Therefore, the boron concentration is acceptable.
For specific power and operating history, NUREG/CR-6665 does not have a specific recommendation. NUREG/CR-6665 estimated this effect to be on the order of 0.002 keff using operating histories it considered. Based on the difficulty of reproducing a bounding or even a representative power operating history, NUREG/CR-6665 merely recommends using a constant power level and retaining sufficient margin to cover the potential effect of a more limiting power history. The licensee used a constant core power for the depletion calculations. The 0.002 keff is a maximum that would be significantly reduced at burnups less than 30GWD/MTU. The site-specific analysis indicates that typically, the burnup profile used in WCAP-16518 provides sufficient margin to accommodate this effect. However, the lack of margin in the burnup profile demonstrated in the site-specific analysis at typical 3.6 w/o base loading with 1.0 w/o axial blankets at 15GWD/MTU indicates some other margin needs to be credited in this instance.
The recalculation of the burnup uncertainty using the NRC staff guidance was done at the maximum enrichment and maximum burnup credited in each storage configuration. The burnup uncertainty would be reduced for this lower enrichment and lower burnup. The overall reduction in the reserved margin would be reduced for this lower enrichment and lower burnup.
Therefore, the reduction in reserved margin due to the recalculation of the burnup uncertainty is sufficient to accommodate this scenario.
BVPS-2 does not utilize fixed burnable poisons such as Burnable Poison Rod Assemblies (BPRAs) and Axial Power Shaping Rod Assemblies (APSRs), so this aspect of NUREG/CR-6665 is not applicable.
NUREG/CR-6665 does not have a specific recommendation for integral burnable poisons. The licensee uses integral burnable poisons. The WCAP-16518 analysis only models integral burnable poisons for one storage configuration. When integral burnable poisons are modeled, they are only modeled for fresh fuel and the integral burnable poisons are reduced by amounts the NRC staff has previously accepted as appropriate for manufacturing and calculation uncertainties. However, the analysis does not consider the effect on spectral hardening. The wide variety of integral burnable poison loadings makes it difficult to evaluate. Some insight may be gained by looking at the work done with BPRAs and APSRs. However, unlike BPRAs and APSRs, integral burnable poisons cannot be removed from the assembly. In response to RAIs concerning the integral burnable poisons, the licensee provided a reactivity comparison for several integral burnable poison loadings of 5.0 w/o enriched fuel (Reference 2). While that information indicates the presence of Xe135, it also indicates that at low burnups, a fresh assembly is significantly more reactive than one loaded with integral burnable poison. As the burnup increases, the reactivity of the various integral burnable poison loadings appear to converge, though still below the assembly without integral burnable poison. Xe135 will be providing some negative reactivity to counter that added by the Pu241 build up. Since the Xe135
will not be present by the time the fuel assembly is transferred from the reactor to the SFP, it is reasonable that the fuel assembly will be more reactive in the SFP than the reactor. For the 5.0 w/o enriched fuel demonstrated in Reference 2, this convergence point would be at a burnup where the BVPS-2 site-specific analysis shows the axial burnup used in WCAP-16518 provides sufficient margin. Lower enrichments should have similar results, although the convergence point would likely be different, and it would be conservative to assume that convergence point is at a lower burnup. For enrichments in the 4.0 w/o range, the BVPS-2 site-specific analysis shows the axial burnup used in WCAP-16518 provides sufficient margin. For enrichments in the 3.6 w/o range, the BVPS-2 site-specific analysis shows the axial burnup used in WCAP-16518 does not demonstrate sufficient margin. However, the NRC staff will apply the same rationale as for the specific power and operating history to accept the WCAP-16518 analysis as is for these scenarios.
3.6 Determination of Soluble Boron Requirements The regulatory requirement for soluble boron credit is that the keff of the spent fuel storage racks loaded with fuel of the maximum fuel assembly reactivity must not exceed 0.95, at a 95 percent probability, 95 percent confidence level, if flooded with borated water.
WCAP-16518-P, Revision 1 and 2, Section 1.1 states, The methodology used in this analysis for soluble boron credit is analogous to that of Reference 1 [R. E. Ginna SER reference 7 herein] and employs analysis criteria consistent with those cited in the Safety Evaluation by the Office of Nuclear Reactor Regulation, Reference 2 [SER to WCAP-14416 reference 8 herein].
Reference 1 was reviewed and approved by the U.S. Nuclear Regulatory Commission (NRC).
However, there are key tenants of those references that were not performed for the BVPS-2 analysis. Additionally, there were several unique modeling aspects from the Ginna analysis that were not replicated in the BVPS-2 analysis. Therefore, the NRC staff does not believe there is ample fidelity between those references and what was done for the BVPS-2 analysis for them to be used as a description of the BVPS-2 soluble boron credit methodology.
Additional information regarding the soluble boron credit methodology used in the BVPS-2 analysis was provided in response to RAI (Reference 2), during the audits, and in Reference 5.
The soluble boron credit methodology WEC used for the BVPS-2 analysis involves calculating a boron worth curve for one storage configuration. In this analysis, it was the 3x3 storage configuration. That boron worth curve is used to determine a soluble boron amount necessary to address each term in the equation below, independent of the other terms. As indicated in the equation, the three terms are summed algebraically to determine the total soluble boron concentration (SBC).
According to WCAP-16518-P, Revisions 1 and 2, the methodology starts with the equation:
SBCTOTAL = SBC95/95 + SBCRE + SBCPA Where, the components of the equations are described as:
SBCTOTAL is the total soluble boron requirement.
SBC95/95 is the soluble boron requirement for 95/95 keff 0.95.
SBCRE is the soluble boron requirement for burnup and reactivity uncertainties.
SBCPA is the soluble boron requirement required to offset accident conditions.
A more accurate definition of SBC95/95 would be the soluble boron required to effect a 0.05 decrease in keff from a zero (0) soluble boron condition. An unstated assumption of this step is that the storage configuration in the unborated analysis is already at a keff of approximately 0.995 with a 95 percent probability at a 95 percent confidence level, and that by decreasing keff by 0.05 the storage configuration will have a keff below 0.95 with a 95 percent probability at a 95 percent confidence level. At this point, there is no need to presume the presence of other boron, so this assumption is reasonable. Another unstated assumption is that the bias and uncertainties calculated for the unborated analysis are unaffected by the soluble boron credited here. This assumption is inherent in the other terms as well. The bias and uncertainties will change with soluble boron present in the water. According to the information provided, the decision to not recalculate the biases and uncertainties was based on engineering judgment that the effect would be small. Given the variation in the biases and uncertainties between the storage configurations, and the lack of a generic accepted methodology, the NRC staff believes this represents a potential non-conservatism. Therefore, the NRC staff believes the analysis must show sufficient margin to overcome this potential non-conservatism. Another unstated assumption is that the soluble boron worth from the one storage configuration is limiting with respect to the other three. Information provided during the audit at the Rockville office, and in Reference 5, allowed the NRC staff to determine the boron worth curve for the storage configuration with the largest reactivity increase due to an abnormal event, the 1-out-of-4 5.0 w/o at 15,000 MWD/MTU. The 1-out-of-4 5.0 w/o at 15,000 MWD/MTU storage configuration boron worth curve had a much greater value than the 3x3 storage configuration, providing reasonable assurance that the limiting boron worth curve was used in the analysis.
A more accurate definition of SBCRE would be the soluble boron required to offset additional uncertainties associated with boron crediting from a zero (0) soluble boron condition. Note, both SBC95/95 and SBCRE are necessary to ensure keff remains below 0.95 with a 95 percent probability at a 95 percent confidence level, not just SBC95/95. The analysis identifies two uncertainties to be accommodated. One is a depletion uncertainty equal to 0.01 keff per 30 GWD/MTU of burnup credited in the analysis. This value is calculated using the maximum burnup credited from any of the four storage configurations in the unborated analysis. In WCAP-16518, the value was approximately 56 GWD/MTU for the 3x3 storage configuration.
Although not explicitly stated, the ratio for determining this uncertainty actually originates in WCAP-14416-NP and is captured in the SE to WCAP-14416 referenced by the licensee. The ratio is based on a comparison of isotopic concentration values generated by the PHEONIX-P code and experimental data. However, the BVPS-2 analysis in WCAP-16518 used the DIT code rather than the PHEONIX-P code for the in reactor depletion portions of the analysis.
During the audit at the Monroeville office, WEC provided indications that the ratio for DIT was probably no more severe than that for PHEONIX-P. This uncertainty appears to be an adjunct
to the burnup uncertainty used in the unborated analysis, providing for the isotopic differences that were not accommodated in the unborated analysis. If this uncertainty were combined with the burnup uncertainty from the unborated analysis, the combination would be on par with that derived using the NRC staffs guidance. Therefore, the NRC staff considers this uncertainty necessary to accommodate the non-conservative burnup uncertainty from the unborated analysis. However, had it been included in the unborated analysis, it would have been convoluted through an RMSS with the other uncertainties, applying it directly here should provide some additional margin. The other is a burnup uncertainty equal to the largest burnup uncertainty calculated from any of the four storage configurations in the unborated analysis.
This is a double counting of a previously applied uncertainty, and therefore, provides additional margin. However, as stated above, the analysis does not consider the impact of soluble boron on the biases and uncertainties, introducing a potential non-conservatism. The NRC staff believes this second counting of the burnup uncertainty should provide ample compensation.
WCAP-16518 uses the boron worth curve to determine the amount of soluble boron required to accommodate each term independent of the other. This parallel counting of soluble boron ignores the decreasing worth of soluble boron as the concentration increases. This parallel counting of soluble boron indicates BVPS-2 requires 441.8 parts per million (PPM) of soluble boron to achieve a keff below 0.95 with a 95 percent probability at a 95 percent confidence level, under normal conditions. A serial counting of soluble boron, including the decreasing worth of soluble boron as the concentration increases, results in soluble boron requirement of approximately 485 PPM of soluble boron to achieve a keff below 0.95 with a 95 percent probability at a 95 percent confidence level, under normal conditions. This point is noteworthy as the BVPS-2 TS 4.3.1.1.c requires BVPS-2 to be less than 0.95 keff, if flooded with water borated to 450 PPM. However, when considering the margin in the depletion uncertainty and burnup uncertainty discussed in the previous paragraph, and the analytical reserved 0.005 keff margin, it seems reasonable to that BVPS-2 will meet this TS requirement with the analysis as is.
The definition of SBCPA is reasonably accurate. The analysis evaluated several potential off normal conditions for all four storage configurations in unborated water. The analysis determined that a misloading event in the 1-out-of-4 5.0 w/o at 15,000 MWD/MTU storage configuration would have the largest reactivity increase. The boron worth curve generated for the 3x3 storage configuration was used to determine the amount of soluble boron required to accommodate the reactivity increase associated with a misloading event in the 1-out-of-4 5.0 w/o at 15,000 MWD/MTU storage configuration, independent of any other soluble boron requirements. Using WCAP-16518s parallel soluble boron counting and considering the largest reactivity increase due to an abnormal condition from the unborated condition, the analysis indicates BVPS-2 requires 824.1 PPM of soluble boron to achieve a keff below 0.95 with a 95 percent probability at a 95 percent confidence level, under abnormal conditions. A serial counting of soluble boron results in a much larger soluble boron requirement. During the audit at the Monroeville office, WEC asserted that using the largest reactivity increase associated with any of the four storage configurations provides sufficient conservatism to accommodate the non-conservatism associated with parallel counting of soluble boron worth. Information provided during the audit at the Rockville office and in Reference 5 indicates that 824.1 PPM of soluble boron is more than sufficient to keep the 1-out-of-4 5.0 w/o at 15,000 MWD/MTU storage configuration keff below 0.95 with a 95 percent probability at a 95 percent confidence level, under abnormal conditions including consideration of the decreasing worth of soluble boron as the concentration increases. However, due to the significant difference in the boron
worth curves for the two storage configurations, the NRC staff considered the maximum abnormal event in the 3x3 storage configuration from WCAP-16518 Table 3-25, using the 3x3 storage configuration boron worth curve provided with WCAP-16518 Table 3-23, and including consideration of the decreasing worth of soluble boron as the concentration increases.
While the maximum abnormal event in the 3x3 storage configuration does not result in a reactivity increase as large as the maximum abnormal event in the 1-out-of-4 5.0 w/o at 15,000 MWD/MTU, it does result in a larger boron requirement. This is due to the significantly lower incremental boron worth associated with the decreasing worth of soluble boron as the concentration increases. In the NRC staffs analysis, the total soluble boron (SBCTOTAL) required to maintain keff below 0.95 with a 95 percent probability at a 95 percent confidence level, under abnormal conditions is approximately 953 PPM, not considering boron depletion. However, if the probable margin in the depletion uncertainty and burnup uncertainty discussed previously is considered and that the BVPS-2 TS requires 2000 PPM of soluble boron in the SFP, it seems reasonable to accept the current analysis as meeting the regulatory requirement to maintain keff below 0.95 with a 95 percent probability at a 95 percent confidence level under abnormal conditions.
As mentioned in Section 3.4 of this SE, there is some indication that not modeling spacer grids is non-conservative in borated water. The potential non-conservatism indicated by the information provided is approximately 0.002 keff. With there being probable margin in the depletion uncertainty and burnup uncertainty as discussed above, along with the BVPS-2 TS requirement for 2000 PPM of soluble boron in the SFP, it is reasonable that there is sufficient margin to accommodate this potential non-conservatism.
3.7 Effects on Human Performance The NRC staff reviewed BVPS-2 UFSAR, Chapter 15, Section 15.4.7, Inadvertent Loading and Operation of a Fuel Assembly in an Improper Position, to determine whether any actions credited in analyzed accident scenarios could be impacted by the proposed change to the BVPS-2 TS.
The following items involving operator actions were identified:
Each fuel assembly is marked with an identification number and loaded in accordance with a core loading diagram. After core loading, the identification numbers are verified by the operators for every assembly in the core. The tasks of identification and verification of fuel assemblies by the operators will not be affected by the proposed changes in the LAR.
During start-up after refueling outages, operators observe incore flux monitors to identify peaking factors, which could result from power distortion due to misplaced fuel assemblies.
The operators also observe thermocouples for the presence of high coolant enthalpy abnormalities. The incore flux monitors and thermocouples will not be affected by the proposed changes in the LAR. Therefore, the ability of operators to observe peaking factor trends and coolant enthalpy will not be affected.
The process of moving fuel is currently controlled by an existing operating procedure and fuel movement sheets. The reactor engineers develop the fuel movement sheets using ShuffleWorks software. The fuel movement process will remain the same after the implementation of the proposed TS change and will not require any additional operator training.
By letter dated May 21, 2007, the NRC staff questioned if the proposed TS change presented any new or increased opportunities for operator error and if any administrative controls were in place to prevent or mitigate operator error. By letter dated July 20, 2007, the licensee stated that the proposed TS change will not present new or increased opportunities for operator error since the fuel movement process as related by procedure and existing operator actions will be unaffected. FENOC also stated that administrative controls are currently in place to prevent miss-characterizing or miss-positioning a fuel assembly. The existing BVPS-2 administrative controls are shown below:
Fuel characterizations are controlled by procedure and are independently reviewed prior to entry in the ShuffleWorks computer software program; Reactor engineers and core design experts prescribe initial and final locations and the movement sequence (fuel movement sheets) using ShuffleWorks; Fuel movement sheets are verified by two individuals; Fuel movements are coordinated by a Fuel Movement Coordinator (FMC);
Fuel movements are independently verified by two individuals visually; Fuel movement activities are tracked against the fuel movement sheets and the sign off of each move is required; Three-way communications are used between the FMC, the reactor crane operator and the pool crane operator to synchronize to and from locations; and Annual pool verification is used to assure correct configuration of the SFP.
The licensee stated that initial setup of the new SFP configuration will require an additional 73 fuel moves. After the initial SFP configuration is made, the number of fuel moves required during each refueling outage will remain approximately the same. Prior to initial setup, the reactor engineers and core design support staff will be trained on the new methodology for characterizing fuel assemblies and determining appropriate locations for each assembly in the SFP.
By letter dated December 21, 2007, the licensee stated that there will be no significant changes to administrative and operational controls that currently protect against criticality and fuel-handling accidents. After reviewing the licensees submittal and RAI responses, the NRC staff has determined that the proposed change does not impact the current operator actions or the timing to perform those actions as credited in the BVPS-2 UFSAR, and that the proposed TS change is acceptable in the area of human performance.
3.8 NRCs Staff Evaluation 3.8.1 Reactor Systems Since the licensee takes credit for soluble boron during accident scenarios, the regulatory requirement is taken from 10 CFR 50.68(b)(4) which states, AIf credit is taken for soluble boron, the k-effective of the spent fuel storage racks loaded with fuel of the maximum fuel assembly reactivity must not exceed 0.95, at a 95 percent probability, 95 percent confidence level, if flooded with borated water, and the k-effective must remain below 1.0 (subcritical), at a 95 percent probability, 95 percent confidence level, if flooded with unborated water.@ The licensee used an analytical acceptance limit of keff < 0.995 for the unborated condition and an analytical acceptance limit of keff < 0.945 for the borated condition. Thus, the analysis reserved 0.005 keff margin.
The NRCs staff evaluation of the licensees submittal for the unborated criteria found several non-conservatisms. For the most part, the licensee was able to identify offsetting conservatisms to maintain the reserved analytical keff margin. However, to accommodate all of the non-conservatisms, the licensee had to reduce the reserved analytical keff margin. The minimum remaining analytical margin is 0.00132 keff for the 1-out-of-4 3.85 w/o Fresh with IFBA storage configuration. While this represents a significant reduction in the reserved analytical keff margin, it is sufficient in view of the above evaluation to allow the NRC staff to reasonably conclude that the licensee meets the regulation that keff must remain below 1.0, at a 95 percent probability, 95 percent confidence level, if flooded with unborated water.
The NRCs staff evaluation of the licensees submittal for the borated criteria also found several non-conservatisms. However, as discussed previously, the additional uncertainties used in the borated analysis coupled with the 2000 PPM of soluble boron, required by the BVPS-2 TS, allow the NRC staff to reasonably conclude that the licensee meets the regulation that keff must remain below 0.95, at a 95 percent probability, 95 percent confidence level, if flooded with borated water.
The NRC staffs acceptance of the information provided should not be construed as concurrence with every assertion in the submittal. For instance, information provided during the audit at the Rockville office, and in Reference 5 indicates that WEC believes the two uncertainties evaluated in the borated analysis could have been combined statistically, and not doing so provides additional margin. The NRC staff believes that would be inappropriate as it would be impossible to imply that a depletion uncertainty and a burnup uncertainty were independent, and would only serve to reduce any margin associated with them.
3.8.2 Human Factors Based on the reviewed information, the NRC staff finds that the proposed TS change does not affect current operator manual actions credited in BVPS-2 UFSAR. The NRC staff also finds that the proposed TS change is acceptable in the area of human performance, due to the licensees use of existing procedures and administrative controls to perform fuel movement activities during refueling outages; its use of trained reactor engineers and core design experts to characterize fuel assemblies and identify proper storage locations; and its use of existing fuel movement equipment, including the software used for developing fuel movement sheets.
4.0 REGULATORY COMMITMENT At BVPS Unit No. 2, fresh fuel assemblies with nominal center-zone enrichments of 3.6 w/o to 4.95 w/o must contain a blanket with a minimum nominal length of 6 inches and with a nominal enrichment that does not exceed 2.6 w/o. Deviations from these conditions will require evaluation/analysis to demonstrate that the WCAP-16518-P, Revision 2, Beaver Valley Unit 2 Spent Fuel Pool Criticality Analysis, V.N.
Kucukboyaci, July 2007, conclusions remain applicable.
At BVPS Unit No. 2, fresh fuel assemblies with nominal center-zone enrichments less than 3.6 w/o must contain a blanket with a minimum nominal length of 6 inches and with a nominal enrichment that does not exceed 1.0 w/o. Deviations from these conditions will require evaluation/analysis to demonstrate that the WCAP-16518-P, Revision 2, Beaver Valley Unit 2 Spent Fuel Pool Criticality Analysis, V.N. Kucukboyaci, July 2007, conclusions remain applicable.
The NRC staff finds that reasonable controls for the implementation and for subsequent evaluation of proposed changes pertaining to the above regulatory commitments are best provided by the licensee's administrative processes, including its commitment management program.
5.0 STATE CONSULTATION
In accordance with the Commission's regulations, the Pennsylvania State official was notified of the proposed issuance of the amendment. The State official had no comments.
6.0 ENVIRONMENTAL CONSIDERATION
The amendment changes a requirement with respect to installation or use of a facility component located within the restricted area as defined in 10 CFR Part 20 and changes surveillance requirements. The NRC staff has determined that the amendment involves no significant increase in the amounts, and no significant change in the types, of any effluents that may be released offsite, and that there is no significant increase in individual or cumulative occupational radiation exposure. The Commission has previously issued a proposed finding that the amendment involves no significant hazards consideration, and there has been no public comment on such finding August 15, 2006 (71 FR 46935). Accordingly, the amendment meets the eligibility criteria for categorical exclusion set forth in 10 CFR 51.22(c)(9). Pursuant to 10 CFR 51.22(b), no environmental impact statement or environmental assessment need be prepared in connection with the issuance of the amendment.
7.0 CONCLUSION
The Commission has concluded, based on the considerations discussed above, that: (1) there is reasonable assurance that the health and safety of the public will not be endangered by operation in the proposed manner, (2) such activities will be conducted in compliance with the Commission's regulations, and (3) the issuance of the amendment will not be inimical to the common defense and security or to the health and safety of the public.
8.0 REFERENCES
- 1.
FirstEnergy Nuclear Operating Company letter L-06-094, James H. Lash, Site Vice President, Beaver Valley Power Station, to U.S. NRC document control desk, re: A Beaver Valley Power Station, Unit Nos. 1 and 2, BV-1 Docket No. 50-334, License No.
DPR-66, BV-2 Docket No. 50-412, License No. NPF-73, License Amendments Request Nos. 333 and 204,@ June 14, 2006. (ADAMS Accession No. ML061700101)
- 2.
FirstEnergy Nuclear Operating Company letter L-07-084, Peter P. Sena III, Site Vice President, Beaver Valley Power Station, to U.S. NRC document control desk, re: A Beaver Valley Power Station, Unit Nos. 1 and 2, BV-1 Docket No. 50-334, License No.
DPR-66, BV-2 Docket No. 50-412, License No. NPF-73, Responses to a Request for Additional Information (RAI dated May 21, 2007) in Support of License Amendment Request Nos. 333 and 204 (TAC Nos. MD2377 and MD2378),@ July 20, 2007. (ADAMS Accession No. ML072050213)
- 3.
FirstEnergy Nuclear Operating Company letter L-07-103, Edward H. Hubley, Acting Director, Maintenance, Beaver Valley Power Station, to US NRC document control desk, re: A Beaver Valley Power Station, Unit Nos. 1 and 2, BV-1 Docket No. 50-334, License No. DPR-66, BV-2 Docket No. 50-412, License No. NPF-73, Supplemental Information for License Amendments Request Nos. 333 and 204 (Revision 2 of WCAP-16518) (TAC Nos. MD2377 and MD2378),@ July 26, 2007. (ADAMS Accession No. ML072110310)
- 4.
FirstEnergy Nuclear Operating Company letter L-07-517, Peter P. Sena III, Site Vice President, Beaver Valley Power Station, to US NRC document control desk, re: A Beaver Valley Power Station, Unit Nos. 1 and 2, BV-1 Docket No. 50-334, License No. DPR-66, BV-2 Docket No. 50-412, License No. NPF-73, License Amendments Request Number 204 Revision 1, (TAC Nos. MD2377 and MD2378),@ December 21, 2007. (ADAMS Accession No. ML073601008)
- 5.
FirstEnergy Nuclear Operating Company letter L-08-100, Peter P. Sena III, Site Vice President, Beaver Valley Power Station, to US NRC document control desk, re: A Beaver Valley Power Station, Unit No. 2, BV-2 Docket No. 50-412, License No. NPF-73, Responses to a Request for Additional Information in Support of License Amendment Request Number 204 Revision 1, (TAC Nos. MD2378),@ March 11, 2008. (ADAMS Accession No. ML080730245)
- 6.
NRC Memorandum from L. Kopp to T. Collins, Guidance on the Regulatory Requirements for Criticality Analysis of Fuel Storage at Light-Water Reactor Power Plants, August 19, 1998. (ADAMS ML003728001)
- 7.
R. E. Ginna Nuclear Power Plant - Amendment re: Revision to the Storage Configuration Requirements Within the Existing Storage Racks and Taking Credit for a Limited Amount of Soluble Boron (TAC NO. MA8443), dated December 7, 2000 (ADAMS ML003761578).
- 8.
WCAP-14416-NP-A, Westinghouse Spent Fuel Rack Criticality Analysis Methodology, November 1996.
- 9.
U.S. NRC letter Non-Conservatisms in Axial Burnup Biases for Spent Fuel Rack Criticality Analysis Methodology, dated July 27, 2001 (ADAMS ML012080337)
- 10.
10 CFR Part 50 Appendix A, General Design Criteria for Nuclear Power Plants
- 11.
WCAP-12610-P-A, VANTAGE+ Fuel Assembly Reference Core Report
- 12.
BVPS-2 UFSAR Revision 16
- 13.
Westinghouse letter LTR-NRC-02-55, Fuel Criterion Evaluation Process (FCEP)
Notification of the RFA-2 Design, Revision 1, (Proprietary), dated November 13, 2002 (ADAMS ML023190181)
- 14.
NUREG/CR-6665, AReview and Prioritization of Technical Issues Related to Burnup Credit for LWR Fuel,@ (ADAMS ML003688150)
- 15.
NUREG/CR-6801, ARecommendations for Addressing Axial Burnup in PWR Burnup Credit Analysis,@ (ADAMS ML03110292)
- 16.
U.S. NRC letter to Prairie Island Nuclear Generating Plant, Prairie Island Nuclear Generating Plant, Units 1 and 2 - Issuance of Amendments RE: Spent Fuel Pool Storage (TAC NOS. MC5811 and MC5812), dated February 5, 2006 (ADAMS ML060520208)
- 17.
DOE Topical Report DOE/RW-0472, Topical Report on Actinide-Only Burnup Credit for PWR Spent Nuclear Fuel Packages, dated September 1998, Revision 2 (ADAMS ML070780665)
Principal Contributors: Kent Wood George Lapinsky Timothy Kolb Date: March 27, 2008