SONGS UNIT 2 SINGLE-SIDED Operating License & Technical Specification/Licensee Controlled Specification AMD 211/203, B05-010, & B06-002 Revise Unit 2 Operating License by removing pages and inserting the enclosed pages.

The revised pages are identified by the captioned amendment number and/or dates and contain marginal/lines indicating the areas of change. Please direct any questions regarding filing of information to: (949) 368-6557 or email CDM Controlled Manuals Desk.

REMOVE:

INSERT:

VOLUME 1 VOLUME 1 BEHIND: List of Effective Pages - "Blue Tab" BEHIND: List of Effective Pages - "Blue Tab" List of Effective Pages - Pages 1-12 3/07/07 List of Effective Pages - Pages 1-12 4/8/07 BEHIND: Facility Operating License "Blue Tab" BEHIND: Facility Operating License "Blue Tab" Facility Operating License Page 2 AMD 209 Facility Operating License Page 2 AMD 211 Page 3 AMD 209 Page 3 AMD 211 BEHIND: Electrical Power Systems "Blue Tab" BEHIND: Electrical Power Systems "Blue Tab" Page 3.8-6 AMD 179 Page 3.8-6 AMD 211 Page 3.8-20 AMD 183 Page 3.8-20 AMD 211 Page 3.8-21 AMD 183 Page 3.8-21 AMD 211 VOLUME 3 VOLUME 3 EHIND: B 3.7 "Blue Tab" BEHIND: B 3.7 "Blue Tab" age B 3.7-51 AMD 127 4/12/01 Page B 3.7-51 AMD 127 4/08/07 BEHIND: B 3.8 - "Blue Tab" BEHIND: B 3.8 - "Blue Tab" Page B 3.8-18 AMD 127 6/18/01 Page B 3.8-18 AMD 211 4/05/07 Page B 3.8-36 AMD 127 No Date Listed Page B 3.8-36 AMD 211 4/05/07 Page B 3.8-38 AMD 127 3/25/02 Page B 3.8-38 AMD 211 4/05/07 Page B 3.8-39 AMD 127 3/25/02 Page B 3.8-39 AMD 211 4/05/07 Page B 3.8-41 AMD 127 3/25/02 Page B 3.8-41 AMD 211 4/05/07 Filing Instructions Reviewed & Approved:

\\wxŽyvý

,4Iv-d) yl Signature/NRA Date

('\\

ýbignature/uuM Processor uate Abe(

Page 1 of 1

APPENDIX A TO LICENSE NO.

NPF-1O SAN ONOFRE UNIT 2 TECHNICAL SPECIFICATIONS LIST OF EFFECTIVE PAGES (NUREG-0741)

Pane No.

Volume Amendment/Date Page No.

Volume Amendment/Date LOEP-1 LOEP-2 LOEP-3 LOEP-4 LOEP-4a LOEP-5 LOEP-6 LOEP-7 LOEP-8 LOEP-9 LOEP-1O LOEP-11 LOEP-12 iiiii iv v

vi vii viii 1.1-1 1.1-2 1.1-3 1

. 1-4 1.1-5 1.1-6 1.1-7 1.2-1 1.2-2 1.2-3 1.3-1 1.3-2 1.3-3 1.3-4 1.3-5 1.3-6 1.3-7 1.3-8 1.3-9 1.3-10 1.3-11 1.3-1.2 1.3-13 1.4-1 1.4-2 1.4-3 1.4-4 211 208 211 211 168 207 200 197 208 204 197 211 193 127 208 208 197 127 208 208 127 127 188 204 203 200 127 127 127 127 127 127 127 127 127 127 127 127 127 127 127 127 127 127 127 127 127 04/08/07 01/25/07 04/04/07 04/04/07 12/21/06 11/18/05 07/19/05 12/05/06 09/19/06 04/08/07 04/05/07 03/07/07 2.0-1 2.0-2 3.0-1 3.0-2 3.0-3 3.0-4 3.0-5 3.1-1 3.1-2 3.1-3 3.1-4 3.1-5 3.1-6

3.

1-7 3.1-8 3.1-9 3.1-10 3.1-11 3.1-12 3.1-13 3.1-14 3.1-15 3.1-16

3. 1-17 3.1-18 3.1-19 3.1-20 3.1-21 3.1-22 3.1-23 3.1-24 3.1-25 3.1-26 3.1-27 3.1-28 3.1-29 3.2-1 3.2-2 3.2-3 3.2-4 3.2-5 3.2-6 3.2-7 3.2-8 3.2-9 3.2-10 3.2-11 3.2-12 207 207 127 127 127 186 127 200 200 200 127 127 127 200 200 127 127 127 200 127 200 200 200 127 127 127 127 163 175 127 127 127 127 127 127 127 127 127 127 127 127 127 127 127 200 127 127 127 Page 1 of 12 Amendment 211 04/08/07

APPENDIX A TO LICENSE NO.

NPF-1O SAN ONOFRE UNIT 2 TECHNICAL SPECIFICATIONS (NUREG-0741)

LIST OF EFFECTIVE PAGES Paae No.

volume Amendment/Date Page No.

Volume Amendment/Date 3.3-1 1

127 3.3-50 1

127 3.3-2 1

127 3.3-51 1

175 3.3-3 1

127 3.3-52 1

127 3.3-4 1

127 3.471 1

149 3.3-5 1

127 3.4-2 1

149 3.3-6 1

147 3.4-3 1

149 3.3-7 1

133 3.4-4 1

127 3.3-8 1

150 3.4-5 1

203 3.3-9 1

150 3.4-6 1

203 3.3-10 1

127 3.4-7 1

203 3.3-11 1

127 3.4-8 1

203 3.3-12 1

133 3.4-9 1

203 3.3-13 1

147 3.4-10 1

203 3.3-14 1

127 3.4-11 1

203 3.3-15 1

127 3.4-12 1

203 3.3-16 1

133 3.4-13 1

127 3.3-17 1

127 3.4-14 1

197 3.3-18 1

127 3.4-15 1

127 3.3-19 1

127 3.4-16 1

175 3.3-20 1

133 3.4-17 1

175 3.3-21 1

127 3.4-18 1

203 3.3-22 1

157 3.4-19 1

175 3.3-23 1

157 3.4-20 1

127 3.3-24 1

157 3.4-21 1

175 3.3-25 1

157 3.4-22 1

203 3.3-26 1

127 3.4-23 1

175 3.3-27 1

127 3.4-24 1

175 3.3-28 1

127 3.4-25 1

175 3.3-29 1

133 3.4-26 1

161 3.3-30 1

127 3.4-27 1

155 3.3-31 1

127 3.4-28 1

156 3.3-32 1

127 3.4-29 1

156 3.3-33 1

127 3.4-30 1

203 3.3-34 1

196 3.4-31 1

203 3.3-35 1

132 3.4-32 1

127 3.3-36 1

132 3.4-33 1

203 3.3-37 1

132 3.4-34 1

143 3.3-38 1

132 3.4-35 1

203 3.3-39 1

132 3.4-36 1

127 3.3-40 1

175 3.4-37 1

204 3.3-41 1

160 3.4-38 1

204 3.3-42 1

208 01/25/07 3.4-39 1

127 3.3-43 1

208 01/25/07 3.4-40 1

127 3.3-44 1

127 3.4-41 1

127 3.3-45 1

194 3.4-42 1

127 3.3-46 1

194 3.4-43 1

127 3.3-47 1

194 3.4-44 1

127 3.3-48 1

127 3.4-45 1

127 3.3-49 1

127 Page 2 of 12 Amendment 208 01/25/07

APPENDIX A TO LICENSE NO.

NPF-iO w

SAN ONOFRE UNIT 2 TECHNICAL SPECIFICATIONS (NUREG-0741)

LIST OF EFFECTIVE PAGES Page No.

Volume Amendment/Date PaQe No.

Volume Amendment/Date 3.4-46 1

127 3.7-6 1

127 3.4-47 1

127 3.7-7 1

127 3.4-48 1

127 3.7-8 1

127 3.4-49 1

127 3.7-9 1

127 3.4-50 1

127 3.7-10 1

127 3.4-51 1

204 3.7-11 1

164 3.4-52 1

204 3.7-12 1

127 3.5-1 1

139 3.7-13 1

127 3.5-2 1

135 3.7-14 1

191 3.5-3 1

127 3.7-15 1

147 3.5-4 1

139 3.7-16 1

162 3.5-5 1

127 3.7-17 1

127 3.5-6 1

190 3.7-18 1

127 3.5-7 1

127 3.7-19 1

127 3.5-8 1

127 3.7-19a 1

129 3.5-9 1

127 3.7-19b

.1 129 3.5-10 1

127 3.7-19c 1

129 3.5-11 1

127 3.7-20 1

127 3.6-1 1

127 3.7-21 1

127 3.6-2 1

144 3.7-22 1

181 3.6-3 1

127 3.7-23 1

127 3.6-4 1

127 3.7-24 1

181 3.6-5 1

127 3.7-25 1

177 3.6-6 1

144 3.7-26 1

177 3.6-7 1

127 3.7-27 1

208 01/25/07 3.6-8 1

127 3.7-28 1

208 01/25/07 3.6-9 1

127 3.7-29 1

127 3.6-10 1

127 3.7-30 1

127 3.6-11 1

127 3.7-31 1

127 3.6-12 1

165 3.7-32 1

131 3.6-13 1

201 3.7-33 1

131 3.6-14 1

201 3.7-34 1

131 3.6-15 1

127 3.7-35 1

127 3.6-16 1

127 3.8-1 1

141 3.6-17 1

127 3.8-2 1

141 3.6-18 1

171 3.8-3 1

127 3.6-19 1

127 3.8-4 1

127 3.6-20 1

127 3.8-5 1

179 3.6-21 1

127 3.8-6 1

211 3.6-22 1

127 3.8-7 1

158 3.6-23 1

159 3.8-8 1

179 3.6-24 1

159 3.8-9 1

158 3.6-25 1

127 3.8-10 1

158 3.6-26 1

127 3.8-11 1

158 3.7-1 1

127 3.8-12 1

158 3.7-2 1

127 3.8-13 1

169 3.7-3 1

127 3.8-14 1

179 3.7-4 1

163 3.8-15 1

158 3.7-5 1

127 3.8-16 1

127 Page 3 of 12 Amendment 211 04/04/07

APPENDIX A TO LICENSE NO.

NPF-1O SAN ONOFRE UNIT 2 TECHNICAL SPECIFICATIONS (NUREG-0741)

LIST OF EFFECTIVE PAGES PaQe No.

Volume Amendment/Date Paoe No.

Volume Amendment/Date 3.8-17 1

127 5.0-8 1

207 3.8-18 1

175 5.0-9 1

178 3.8-19 1

127 5.0-10 1

127 3.8-20 1

211 5.0-11 1

170 3.8-21 1

211 5.0-12 1

178 3.8-22 1

127 5.0-13 1

204 3.8-23 1

127 5.0-14 1

204 3.8-24 127 5.0-15 1

206 3.8-25 1

127 5.0-15a 1

206 3.8-26 1

127 5.0-16 1

204 3.8-27 1

175 5.0-17 1

208 3.8-28 1

127 5.0-18 1

204 3.8-29 1

127 5.0-19 1

204 3.8-30 1

127 5.0-20 1

204 3.8-31 1

127 5.0-20a 1

198 3.8-32 1

127 5.0-20b 1

144 3.8-33 1

127 5.0-21 1

127 3.8-34 1

127 5.0-22 1

127 3.8-35 1

127 5.0-23 1

195 3.8-36 1

175 5.0-24 1

127 3.8-37 1

127 5.0-25 1

127 3.8-38 1

127 5.0-26 1

200 3.8-39 1

127 5.0-27 1

203 3.8-40 1

175 5.0-27a 1

203 3.8-41 1

127 5.0-28 1

204 3.9-1 1

127 5.0-29 1

204 3.9-2 1

175 5.0-30 1

197 3.9-3 1

127 5.0-31 1

207 3.9-4 1

193 3.9-5 1

127 3.9-6 1

175 3.9-6a 1

175 3.9-7 1

153 3.9-8 1

153 3.9-9 1

175 3.9-9a 1

153 3.9-10 1

134 4.0-1 1

199 4.0-2 1

127 4.0-3 1

127 4.0-4 1

131 4.0-5 1

131 5.0-1 1

207 5.0-2 1

207 5.0-3 1

207 5.0-4 1

207 5.0-5 1

207 5.0-6 1

184 5.0-7 1

127 Page 4 of 12 Amendment 211 04/04/07

APPENDIX A TO LICENSE NO.

NPF-10 SAN ONOFRE UNIT 2 TECHNICAL SPECIFICATIONS (NUREG-0741)

LIST OF EFFECTIVE PAGES Page No.

Bibliographic Data Sheet Appendix B Unit 2 Environmental Protection Plan I-1 2-1 2-2 3-1 3-2 4-1 4-2 Appendix C Anti Trust Conditions Appendix C 2

3 Vol ume Amendment/Date dated February 17, 1982 dated February 17, 1982 dated February 17, 1982 dated February 17, 1982 dated February 17, 1982 dated February 17, 1982 dated February 17, 1982 168 168 dated February 17, 1982 dated dated dated February February February 17, 17, 17, 1982 1982 1982 Page 4a of 12 Amendment 168

APPENDIX A TO LICENSE NO.

NPF-1O SAN ONOFRE UNIT 2 TECHNICAL SPECIFICATIONS (NUREG-0741)

LIST OF EFFECTIVE PAGES Page No.

Volume Amendment/Date PaQe No.

Volume Amendment/Date B 2.0-1 2

192 07/19/04 B 3.1-27 2

127 B 2.0-2 2

127 B 3.1-28 2

200 11/18/05 B 2.0-3 2

207 12/21/06 B 3.1-29 2

200 11/18/05 B 2.0-3a 2

192 07/19/04 B 3.1-30 2

200 11/18/05 B 2.0-4 2

207 12/21/06 B 3.1-31 2

127 B 2.0-5 2

207 12/21/06 B 3.1-32 2

127 05/02/97 B 2.0-6 2

127 B 3.1-33 2

127 B 2.0-7 2

127 B 3.1-34 2

127 05/02/97 B 2.0-8 2

207 12/21/06 B 3.1-35 2

127 B 2.0-9 2

207 12/21/06 B 3.1-36 2

127 B 3.0-1 2

127 B 3.1-37 2

200 11/18/05 B 3.0-2 2

127 B 3.1-38 2

200 11/18/05 B 3.0-3 2

127 B 3.1-39 2

127 B 3.0-4 2

207 12/21/06 B 3.1-40 2

127 B 3.0-5 2

127 B 3.1-41 2

127 B 3.0-6 2

127 B 3.1-42 2

127 B 3.0-7 2

127 B 3.1-43 2

200 11/18/05 B 3.0-8 2

127 B 3.1-43a 2

200 11/18/05 B 3.0-9 2

127 B 3.1-44 2

200 11/18/05 B 3.0-10 2

127 B 3.1-45 2

127 B 3.0-11 2

127 B 3.1-46 2

200 11/18/05 B 3.0-12 2

127 12/01/98 B 3.1-47 2

127 B 3.0-13 2

186 10/25/02 B 3.1-48 2

127 B 3.0-14 2

186 05/08/02 B 3.1-49 2

127 B 3.0-15 2

186 05/08/02 B 3.1-50 2

127 B 3.1-1 2

200 11/18/05 B 3.1-51 2

127 B 3.1-2 2

200 11/18/05 B 3.1-52 2

127 B 3.1-3 2

200 11/18/05 B 3.1-53 2

127 B 3.1-4 2

200 11/18/05 B 3.1-54 2

127 08/03/01 B 3.1-5 2

Deleted B 3.1-55 2

127 08/03/01 B 3.1-6 2

Deleted B 3. 1-56 2

127 08/03/01 B 3.1-7 2

200 11/18/05 B 3.1-57 2

127 08/03/01 B 3.1-8 2

200 11/18/05 B 3.1-58 2

127 08/03/01 B 3.1-9 2

200 11/18/05 B 3.1-58a 2

127 08/03/01 B 3.1-10 2

200 11/18/05 B 3.1-58b 2

127 08/03/01 B 3.1-11 2

Deleted B 3.1-59 2

200 11/18/05 B 3.1-12 2

Deleted B 3.1-60 2

127 11/05/96 B 3.1-13 2

127 B. 3.1-61 2

127 05/03/00 B 3.1-14 2

127 B 3.1-62.

2 175 12/20/00 B 3.1-15 2

200 11/18/05 B 3.1-63 2

175 05/21/02 B 3.1-16 2

127 B 3.1-63a 2

175 12/20/00 B 3.1-17 2

200 11/18/05 B 3.1-64 2

127 B 3.1-18 2

127 B 3.1-65 2

127 B 3.1-19 2

127 01/03/02 B 3.1-66 2

127 B 3.1-20 2

127 B 3.1-67 2

127 B 3.1-21 2

127 01/03/02 B 3.1-68 2

127 B 3.1-22 2

127

.05/30/97 B 3.1-69 2

127 B 3.1-23 2

127 B 3.1-70 2

127 B 3.1-24 2

127 B 3.1-71 2

127 B 3.1-25 2

127 05/02/97 B 3.1-72 2

127 B 3.1-26 2

127 07/29/99 Page 5 of 12 Amendment 207 12/21/06

APPENDIX A TO LICENSE NO.

NPF-10 e

SAN ONOFRE UNIT 2 TECHNICAL SPECIFICATIONS (NUREG-0741)

LIST OF EFFECTIVE PAGES Paoe No.

Volume Amendment/Date Pane No.

Volume Amendment/Date B 3.1-73 2

127 B 3.3-2 2

127 07/17/97 B 3.1-74 2

127 B 3.3-3 2

127 B 3.1-75 2

127 B 3.3-4 2

127 B 3.1-76 2

127 B 3.3-5 2

127 B 3.1-77 2

127 05/29/97 B 3.3-6 2

127 B 3.1-78 2

127 05/29/97 B 3.3-7 2

127 B 3.1-79 2

127 B 3.3-8 2

127 B 3.1-80 2

127 B 3.3-9 2

127 B 3.2-1 2

127 B 3.3-10 2

127 B 3.2-2 2

127 83.3-11 2

127 B 3.2-3 2

127 B 3.3-12 2

127 03/12/99 B 3.2-4 2

192 07/19/04 B 3.3-13 2

127 B 3.2-5 2

127 B 3.3-14 2

127 B 3.2-6 2

127 B 3.3-15 2

127 B 3.2-7 2

127 B 3.3-16 2

127 07/17/97 B 3.2-8 2

127 B 3.3-17 2

127 09/16/03 B 3.2-9 2

127 B 3.3-18 2

127 03/12/99 B 3.2-10 2

127 B 3.3-19 2

127 B 3.2-11 2

127 B 3.3-20 2

127 B 3.2-12 2

192 07/19/04 B 3.3-21 2

127 03/12/99 B 3.2-13 2

127 B 3.3-22 2

127 03/12/99 B 3.2-14 2

127 B 3.3-23 2

127 03/12/99 B 3.2-15 2

127 B 3.3-24 2

127 B 3.2-16 2

127 83.3-25 2

127 12/30/96 B 3.2-17 2

127 B 3.3-26 2

127 12/30/96 B 3.2-18 2

127 B 3.3-26a 2

127 12/30/96 B 3.2-19 2

192 07/19/04 B 3.3-27 2

127 B 3.2-20 2

127 B 3.3-28 2

127 B 3.2-21 2

127 B 3.3-29 2

127 B 3.2-22 2

127 B 3.3-30 2

127 05/29/97 B 3.2-23 2

127 B 3.3-31 2

127 05/02/97 B 3.2-24 2

127 B 3.3-32 2

127 03/12/99 B 3.2-25 2

127 B 3.3-33 2

127 03/12/99 B 3.2-26 2

127 B 3.3-34 2

127 03/12/99 B 3.2-27 2

127 B 3.3-35 2

127 03/12/99 B 3.2-28 2

127 B 3.3-36 2

127 03/12/99 B 3.2-29 2

192 07/19/04 B 3.3-37 2

188 B 3.2-30 2

200 11/18/05 B 3.3-37a 2

188 09/16/03 B 3.2-31 2

127 B 3.3-38 2

127 B 3.2-32 2

127 B 3.3-39 2

127 07/17/97 B 3.2-33 2

127 B 3.3-40 2

127 09/25/98 B 3.2-34 2

127 B 3.3-41 2

127 09/25/98 B 3.2-35 2

127 B 3 3-42 2

127 B 3.2-36 2

127 B 3.3743 2

127 B 3.2-37 2

127 B 3.3-44 2

127 12/30/96 B 3.2-38 2

192 07/19/04 B 3.3-45 2

127 12/30/96 B 3.2-39 2

127 B 3.3-46 2

127 12/3,0/96 B 3.2-40 2

127 B 3.3-47 2

127 12/30/96 B 3.2-41 2

127 B 3.3-48 2

127 09/18/98 B 3.3-1 2

127 B 3.3-49 2

127 09/18/98 Page 6 of 12 Amendment 200 11/18/05

APPENDIX A TO LICENSE NO. NPF-IO SAN ONOFRE UNIT 2 TECHNICAL SPECIFICATIONS LIST OF FFFFCTIVE PAGES (NUREG-0741)

Page No.

Volume Amendment/Date Paqe No.

Volume Amendment/Date B 3.3-50 B 3.3-51 B 3.3-52 B 3.3-53 B 3.3-54 B 3.3-55 B 3.3-56 B 3.3-57 B 3.3-58 B 3.3-59 B 3.3-60 B 3.3-61 B 3.3-62 B 3.3-63 B 3.3-64 B 3.3-65 B 3.3-66 B 3.3-67 B 3.3-68 B 3.3-69 B 3.3-70 B 3.3-71 B 3.3-72 B 3.3-73 B 3.3-74 B 3.3-75 B 3.3-76 B 3.3-77 B 3.3-78 B 3.3-79 8 3.3-80 B 3.3-81 B 3.3-82 B 3.3-83 B 3.3-84 B 3.3-85 B 3.3-86 B 3.3-87 B 3.3-88 B 3.3-89 B 3.3-90 B 3.3-91 B 3.3-92 B 3.3-93 B 3.3-94 B 3.3-95 B 3.3-96 B 3.3-97 B 3.3-98 B 3.3-99 2

2 2

2 2

2 2

2 2

2 2

2 2

2 2

2 2

2 2

2 2

2 2

2 2

2 2

2 2

2

  • 2 2

2 2

2 2

2 2

2 2

2 2

2 2

2 2

2 2

2 2

127 127 127 127 127 127 127 127 127 127 127 127 127 127 127 127 127 127 127 127 127 127 127 127 127 127 127 127 127 127 127 127 127 127 127 127 127 127 127 127 127 127 127 127 127 127 127 127 127 127 09/18/98 02/11/02 07/17/97 09/18/98 09/18/98 09/18/98 07/17/97 12/30/96 12/30/96 12/30/9 6 05/28 / 97 12/30/96 07/17/97 02/24//99 07/17/97 10/06/99 10/06/99 10/06/99 07/18/01 10/06/99 3.3-100 3.3-101 3.3-102 3.3-103 3.3-103a 3.3-103b 3.3-103c 3.3-104 3.3-105 3.3-106 3.3-107 3.3-108 3.3-109 3.3-110 3.3-111 3.3-112 3.3-113 3.3-114 3.3-115 3.3-116

3. 3-118 3.3-119 3.3-120 3.3-121 3.3-122 3.3-123 3.3-124 3.3-125 3.3-126 3.3-127 3.3-128 3.3-129 3.3-130 3.3-131 3.3-132 3.3-133 3.3-134
3. 3-135 3.3-136 3.3-137 3.3-138 3.3-139 3.3-140 3.3-141 3.3-142 3.3-143 3.3-144 3.3-145 3.3-146 197 127 127 127 188 157 188 127 127 127 127 127 127 127 127 127 127 127 127 127

~1

-~7 IL-/127 127 127 127 127 127 127 127 127 127 127 127 127 127 127 127 174 127 127 127 127 127 127 127 127 127 127 127 127 07/19/05 10/06/99 10/06/99 10/06/99 09/16/03 12/30/96 12/ 30/96 12/30/96 12/30/96 05/28/97 05/28/97 05/28/97 09/06/00 09/06/00 05/29/97 07/13/99 12/14/00 05/28/97 06/09/00 05/28/97 05/28/97 05/28/97 05/28/97 05/28/97 05/28/97 05/28/97 05/28/97 06/27/97 03/19/98 Page 7 of 12 Amendment 197 07/19/05

APPENDIX A TO LICENSE NO. NPF-10 SAN ONOFRE UNIT 2 TECHNICAL SPECIFICATIONS (NUREG-0741)

LI1ST OF EFFECTIVE PAGES Paae No.

Volume Amendment/Date Paqe No.

Volume Amendment/Date B 3.3-147 B 3 3-148 B 3.3-14.9 B 3.3-150 B 3.3-151 B 3.3-152 B 3.3-153 B 3.3-154 B 3.3-155 B 3.3-156 B 3.3-157 B 3.3-158 B 3.3-159 B 3.3-160 B 3.3-161 B 3.3-162 B 3.3-163 B 3.3-164 B 3.3-165 B 3.3-166 B 3.3-167 B 3.3-168 B 3.3-169 B 3.3-170 B 3.3-171 B 3.3-172 B 3.3-173 B 3.3-174 B 3.3-175 B 3.3-176 B 3.3-177 B 3.3-178 B 3-3-179 B 3.3-180 B 3.3-181 B 3.3-182 B 3.3-183 B 3.3-184 B 3.3-185 B 33.4-1 B 3.4-2 B 3.4-3 B 3.4-4 B 3.4-5 B 3.4-6 B 3.4-7 B 3.4-8 B 3.4-9 B 3.4-10 B 3.4-11 127 175 175 127 127 208 208 208 208 208 208 127 127 127 127 127 130 127 127 194 127 127 127 127 194 194 127 127 127 127 127 127 127 127 127 175 175 175 175 127 127 127 127 127 127 127 127 203 127 127 06/27/97 12/20 /00 12/20/00 08/20/01 06/27/97 12/0 5/06 12/05/06 12/0 5/06 12/05/06 12/0 5/06 12/05/06 12/17/98 06/08/00 06/23/99 05/30/97 05/30/97 05/30/97 05/30/97 05/30/97 04/25/05 05/30/97 12/02/99 05/30/97 04/25/05 04/25/05 05/30/97 05/30/97 03/06/06 10/30/98

.10/30/98 04/24/01 04/24/01 07/29/96 12/20/00 12/20/00 12/20/00 12/20/00 02/24/99 02/24/99 02/24/99 3.4-12 3.4-13 3.4-14 3 4-15 3.4-16 3.4-17 3.4-18 3.4-19 3.4-20 3.4-21 3.4-22 3.4-23 3.4-24 3.4-25 3.4-26 3.4-27 3.4-28 3.4-29 3.4-30 3.4-31 3.4-32 3.4-33 3.4-34 3.4-35 3.4-36 3.4-37 3.4-38 3.4-38a 3.4-39 3.4-40 3.4-41 3.4-42 3.4-43 3.4-44 3.4-45 3.4-46 3.4-47 3.4-48 3.4-49 3.4-50 3.4-51 3.4-52 3.4-53 3.4-54 3.4-55 3.4-56 3.4-57 3.4-58 3.4-59 3.4-60 127 127 127 203 203 197 197 127 197 197 127 127 204 127 127 127 204 175 175 127 204 127 175 175 127 175 175 175 204 175 127 127 175 175 175 127 155 161 127 127 156 156 156 156 203 203 203 203 203 203 07/19/05 07/19/05 07/19/05 07/19/05 12/20/00 12/20/00 12/20/00 12/20/00 12//20/00 07/15/05 04/03/06 12/20/00 12/20/00 04/03/06 12/20/00 05/30/00 05/30/00 05/15/02 05/30/00 05/30/00 03/22/01 03/22/01 03/22/01 04/27/05 Page 8 of 12 Amendment 208 12/05/06

APPENDIX A TO LICENSE NO.

NPF-10 SAN ONOFRE UNIT 2 TECHNICAL SPECIFICATIONS (NUREG-0741)

LIST OF EFFECTIVE PAGES Page No.

Volume Amendment/Date PaQe No.

Volume Amendment/Date B 3.4-61 3

203 B 3.5-11 3

127 03/03/00 B 3 4-62 3

203 B 3.5-12 3

127 03/03/00 B 3.4-63 3

203 B 3.5-13 3

127 03/03/00 B 3.4-64 3

203 B 3.5-14 3

127 03/03/00 B 3.4-65 3

203 B 3.5-15 3

127 03/03/00 B 3.4-66 3

203 B 3.5-16 3

197 07/19/05 B 3.4-67 3

203 B 3.5-17 3

127 03/03/00 B 3.4-68 3

203 B 3.5-18 3

127 03/14/02 B 3.4-69 3

203 B 3.5-19 3

127 03/14/02 B 3.4-70 3

127 B 3.5-20 3

127 07/17/01 B 3.4-71 3

204 B 3.5-20a 3

127 03/03/00 B 3.4-72 3

204 B 3.5-21 3

127 B 3.4-73 3

204 B 3.5-22 3

127 B 3.4-74 3

204 B 3.5-23 3

127 B 3.4-75 3

204 B 3.5-24 3

127 B 3.4-76 3

127 B 3.5-25 3

127 B 3.4-77 3

127 B 3.5-26 3

127 B 3.4-78 3

127 B 3.5-27 3

127 B 3.4-79 3

127 B 3.5-28 3

127 B 3.4-80 3

127 09/06/00 B 3.5-29 3

127 B 3 4-81 3

127 09/06/00 B 3.5-30 3

127 B 3 4-82 3

127 B 3.5-31 3

127 B 3 4-83 3

127 B 3.5-32 3

127 B 3 4-84 3

127 B 3.5-33 3

127 B 3.4-85 3

127 B 3.5-34 3

127 B 3.4-86 3

127 B 3.6-1 3

127 12/01/98 B 3.4-87 3

127 B 3.6-2 3

182 04/29/03 B 3.4-88 3

127 05/13/02 B 3.6-3 3

127 12/01/98 B 3.4-89 3

127 05/13/02 B 3.6-4 3

127 04/29/03 B 3.4-90 3

127 B 3.6-5 3

127 12/01/98 B 3.4-91 3

127 B 3.6-6 3

182 02/11/02 B 3.4-92 3

127 B 3.6-7 3

127 B 3.4-93 3

204 B 3.6-8 3

127 B 3.4-94 3

204 B 3.6-9 3

127 B 3.4-95 3

204 B 3.6-10 3

127 B 3.4-96 3

204 B 3.6-11 3

127 12/01/98 B 3.4-97 3

204 B 3.6-12 3

127 04/29/03 B 3.4-98 3

204 B 3.6-13 3

127 07/29/99 B 3.4-99 3

204 B 3.6-14 3

127 B 3.4-100 3

204 B 3.6-15 3

127 B 3.5-1 3

127 B 3.6-16 3

127 04/29/03 B 3.5-2 3

127 B 3.6-17 3

127 B 3.5-3 3

127 B 3.6-18 3

127 06/09/00 B 3.5-4 3

127 05/05/03 B 3.6-19 3

127 B 3.5-5 3

127 05/30/97 B 3.6-20 3

127 B 3 5-6 3

127 B 3.6-21 3

127 04/29/03 B 3 5-7 3

127 07/15/98 B 3.6-22 3

127 10/24/01 B 3 5-8 3

197 07/19/05 B 3.6-23 3

201 12/12/05 B 3 5-9 3

127 07/15/98 B 3.6-24 3

201 12/12/05 B 3.5-10 3

127 07/15/98 B 3.6-24a 3

201 12/12/05 B 3.5-,0a 3

197 07/19/05 B 3.6-25 3

127 04/29/03 Page 9 of 12 Amendment 204 09/19/06

APPENDIX A TO LICENSE NO.

NPF-1O SAN ONOFRE UNIT 2 TECHNICAL SPECIFICATIONS (NUREG-0741)

LIST OF EFFECTIVE PAGES Page No.

Volume Amendment/Date Page No.

Volume Amendment/Date B 3.6-26 B 3.6-27 B 3.6-28 B 3.6-29 B 3.6-30 B 3.6-31 B 3.6-32 B 3.6-33 B 3.6-34 B 3.6-35 B 3.6-36 B 3.6-37 B 3.6-38 B 3.6-39 B 3.6-40 B 3.6-41 B 3.6-42 B 3.6-43 B 3.6-44 B 3.6-45 B 3.6-46 B 3.6-47 B 3.6-48 B 3.6-49 B 3.6-50 B 3.6-51 B 3.6-52 B 3.6-53 B 3.6-54 B 3.6-55 B 3.6-56 B 3.6-57 B 3.7-1 B 3.7-2 83.7-3 83.7-4 B 3.7-5 B3.7-6 B 3.7-7 83.7-8 83.7-9 B 3.7-10 B 3.7-11 B 3.7-12 B 3.7-13 B 3.7-14 B 3.7-15 B 3.7-16 B 3.7-17 B 3.7-18 B 3.7-19 127 182 182 127 127 182 127 127 127 182 182 197 197 127 127 127 127 127 127 127 127 127 159 159 159 159 159 159 159 159 159 159 127 127 127 127 127 127 127 127 127 127 127 127 127 127 127 127 127 127 127 04/29/03 07/11/02 02/11/02 04/29/03 05/02/02 02/11/02 02/11/02 07/19/05 07/19/05 10/06/00 10/06/00 10/06/00 04/29/03 10/29 /99 10/29/99 10/29/99 10/29/99 10/29/99 10/06/00 10/06/00 10/29/99 10/29/99 10/29/99 08/13/01 08/18/98 08/18/98 04/16/99 06/23//99 3.7-20 3.7-21 3.7-22 3.7-23 3.7-24 3.7-25 3.7-26 3.7-27 3.7-28 3.7-29 3.7-30 3.7-31 3.7-32 3.7-33 3.7-34 3.7-35 3.7-36 3.7-37 3.7-38 3.7-39 3.7-40 3.7-41 3.7-42 3.7-43 3.7-43a 3.7-43b 3.7-43c 3 7-43d 3.7-43e 3.7-43f 3.7-43g 3.7-43h 3.7-43i 3.7-43j 3.7-44 3.7-45 3.7-46 3.7-47 3.7-48 3.7-49 3.7-50 3.7-50a 3.7-51 3.7-52 3.7-53 3.7-54 3.7-55 3.7-55a 3.7-56 3.7-57 3.7-58 127 127 127 127 127 127 127 127 127 127 127 191 191 191 127 127 127 127 127 127 127 127 127 127 127 127 129 129 129 129 129 129 129 129 127 127 127 127 127 127 197 197 127 127 127 127 127 127 127 127 127 06/02/04 06/02/04 06/02/04 07/29/99 12/14/00 02/28/01 02/28/01 03/03/00 03/03/00 03/03/00 11/25/03 11/25/03 11/25/03 03/03/00 07/31/00 07/31/00 08/13/01 08/01/01 06/23/99 04/03/06 05/29/97 08/09/96 05/30/97 10/17/01 03/07/07 03/07/07 04/08/07 10/17/01 04/12/01 04/12/01 03/07/07 03/07/07 06/28/99 04/25/05 01/13/99 04/16/99 06/02/04 Page 10 of 12 Amendment 197 04/08/07

APPENDIX A TO LICENSE NO.

NPF-1O SAN ONOFRE UNIT 2 TECHNICAL SPECIFICATIONS (NUREG-0741)

LIST OF EFFECTIVE PAGES Page No.

Volume Amendment/Date Pace No.

Volume Amendment/Date B 3.7-59 B 3.7-60 B 3.7-61 B 3.7-62 B 3.7-62a B 3.7-63 B 3.7-64 B 3.7-65 B 3.7-66 B 3.7-67 B 3.7-68 B 3.7-69 B 3.7-70 B 3.7-71 B 3.7-72 B 3.7-73 B 3.7-74 B 3.7-75 B 3.7-76 B 3.7-77 B 3.7-78 B 3.7-79 B 3.8-1 B 3.8-2 B 3.8-3 B 3.8-4 B 3.8-5 B 3.8-6 B 3.8-7 B 3.8-7a B 3.8-8 B 3.8-9 B 3.8-10 B 3.8-11 B 3.8-12 B 3.8-13 B 3.8-14 B 3.8-15 B 3.8-16 B 3.8-17 B 3.8-18 B 3.8-19 B 3.8-20 B 3.8-21 B 3.8-22 B 3.8-23 B 3.8-24 B 3.8-25 B 3.8-26 B 3.8-27 B 3.8-28 128 127 128 128 128 208 208 208 208 208 127 127 127 127 127 127 127 127 127 127 127 127 127 127 127 127 127 127 197 127 127 127 197 127 127 127 127 127 127 127 211 127 127 127 127 127 127 127 127 127 127 02 05/01 08 06/03 09/16/03 02 05/01 02/05/01 12/05/06 12/05/06 12 05/06 12/05/06 12/05/06 06/23/99 10/13/98 10/13/98 04 29/03 04/29/03 04/29/03 05/13/02 10/06/ 99 10/06/99 10/06/99 10/06/99 10/06/99 10/06/99 07/19/05 12//10/99 10/06/99 10/06/99 07/19/05 10/06/99 10/06/99 10/06/99 10/06/99 10/06/99 06/18/01 06/18/01 04/05/07 06/18/001 06/18/01 06/18/01 06/18/01 06/18/01 06/18/01 06/18/01 06/18/01 06/ 18/01 06/18/01 3.8-29 3.8-29a 3.8-29b 3.8-29c 3.8-29d 3.8-29e 3.8-29f 3.8-30 3.8-31 3.8-32 3.8-33 3.8-34 3.8-35 3.8-36 3.8-37 3.8-38 3.8-39 3.8-40 3.8-41 3.8-42 3.8-43 3.8-44 3.8-45 3.8-46 3.8-47 3.8-47a 3.8-48 3.8-49 3.8-50 3.8-51 3.8-52 3.8-53 3.8-54 3.8-55 3.8.55a 3.8-56 3.8-57 3.8-58 3.8-59 3.8-60 3.8-61 3.8-62 3.8-63 3.8-64 3.8-65 3.8-66 3.8-67 3.8-68 3.8-69 3.8-70 127 169 169 169 169 169 169 127 127 127 127 175 175 211 127 211 211 127 211 127 127 127 127 127 127 127 127 127 127 127 127-127 127 127 127 127 127 175 175 127 127 127 127 127 127 127 127 127 127 127 06/18/01 06/18/01 06/18/01 06/18/01 06/18/01 06/18/01 06/18/01 12/20/00 12/20/00 04/05/07 01/21/98 04/05/07 04/05/07 01/21/98 04/05/07 03/25/02 03/25/02 05/03/00 01/22/99 01/22/99 01/22/99 01/22/99 08/05/98 08/30/04 08/05/98 12/20/00 12/20/00 07/31/00 Page 11 of 12 Amendment 211 04/05/07

APPENDIX A TO LICENSE NO.

NPF-10 SAN ONOFRE UNIT 2 TECHNICAL SPECIFICATIONS (NUREG-0741)

LIST OF EFFECTIVE PAGES Page No.

Volume Amendment /Date Paqe No.

Volume Amendment/Date 3.8-71 3.8-72 3.8-73 3.8-74 3.8-75 3.8-76 3.8-77 3.8-78 3.8-79 3.8-80 3.8-81 3.8-82 3.8-83 3.8-84 3.8-85 3.8-86 3.8-87 3.9-1 3.9-2 3.9-3 3.9-4 3.9-5 3.9-6 3.9-7 3.9-8 3.9-9 3.9-10 3.9-11 3.9-12 3.9-13 3.9-13a 3.9-14 3.9-15 3.9-16 3.9-17

3. 9-17a 3.9-18 3.9-19 3.9-20 3.9-21 3.9-22 3.9-23 3.9-24
3. 9-24a 3.9-25 3.9-26 3.9-27 3

3 3

3 3

3 3

3 3

3 3

3 3

127 127 175 175 127 127 127 127 127 127 127 127 127 127 127 175 175 127 127 175 127 127 175 127 127 127 193 127 127 193 193 127 127 127 127 127 175 175 127 127

127, 127 175 175 127 127 127 12/20/Do 12/20/00 01/11/07 12120/00 12/20/00 12/20/00 12/20/00 12/01/98 02/18/05 10/10/97 10/10/97 02/18/05 02/18/05 10/10/97 10/10/97 07/15/05 04/03/06 07/15/05 12/20/00 05/30/97 07/15/05 04/03/06 12/20/00 12/20/00 05/30/97 10/13/98 10/13/98 Page 12 of 12 Amendment 193 03/07/07 SAN ONOFRE UNIT 2 FACILITY OPERATING LICENSE LIST OF EFFECTIVE PAGES Facility Oneratino License Page No.

Amendment No.

1 2

3 4

5 6

7 8

9 185 209 211 185 185 185 185 205 185 (3)

SCE, pursuant to the Act and 10 CFR Part 70, to receive.

possess, and use at any time special nuclear material as reactor
Fuel, in accordance wiltI the limitations for s orage and amounts required for reactor operation, as described in the Final Safety Analysis Report, as supplemented and amended; (4)

SCE, pursuant to the Act and 10 CFR Parts 30, 40, and 70, to receive, possess, and use at any time any byproduct, source and special nuclear material as sealed neutron sources for reactor startup, sealed sources for reactor instrumentation and radiation monitoring equipment calibration, and as fission detectors in amounts as required; (5)

SCE, pursuant to the Act and 10 CFR Parts 30, 40, and 70, to receive, possess, and use in amounts as required any byproduct, source or special nuclear material without restriction to chemical or physical form, for sample analysis or instrument calibration or associated with radioactive apparatus or components; and (6)
SCE, pursuant to the Act and 10 CFR Parts 30, 40, and 70, to possess, but not separate, such byproduct and special nuclear materials as may be produced by the operation of San Onofre Nuclear Generating Station, Units 1 and 2 and by the decommissioning of San Onofre Nuclear Generating Station Unit 1.

C.

This license shall be deemed to contain and is subject to the conditions specified in the Commission's regulations set forth in 10 CFR Chapter I and is subject to all applicable provisions of the Act and to the rules, regulations and orders of the Commission now or hereafter in effect; and is subject to the additional conditions specified or incorporated below:

(1)

Maximum Power Level Southern California Edison Company (SCE) is authorized to operate the facility at reactor core power levels not in excess of full power (3438 megawatts thermal).

(2)

Technical Specifications The Technical Specifications contained in Appendix A and the Environmental Protection Plan contained in Appendix B, as revised through Amendment No.

211, are hereby incorporated in the license.

Southern California Edison Company shall operate the facility in accordance with the Technical Specifications and the Environmental Protection Plan.

Amendment No.

211

AC Sources-Operating 3.8.1 SURVEILLANCE REQUIREMENTS (continued) 0 SURVEILLANCE FREQUENCY i

SR 3.8.1.3


NOTES----------------

1.

DG loadings may include gradual loading as recommended by the manufacturer.

2.

Momentary transients outside the load range do not invalidate this test.

3.

This Surveillance shall be conducted on only one DG at a time.

4.

This SR shall be preceded by, and immediately follow without shutdown, successful performance of SR 3.8.1.2 or SR 3.8.1.7.

a

5.

To ensure Operability of an AVR, must have been aligned to the DG during the performance of SR 3.8 and SR 3.8.1.3 within the last 60 days, plus any allowance per SR 3.0.2.

it

.1.2 Verify each DG is synchronized and loaded, and operates for > 60 minutes at a load

> 4450 kW and

  • 4700 kW.

As specified in Table 3.8.1-1 SR 3.8.1.4 Verify each day tank contains 2 31.5 inches 31 days of fuel oil.

SR 3.8.1.5 Check for and remove accumulated water from 31 days each day tank.

SR 3.8.1.6 Verify the fuel oil transfer system 31 days operates to transfer fuel oil from storage tank to the day tank.

(continued)

Amendment No. 211 1

SAN ONOFRE--UNIT 2 3.8-6

Diesel Fuel Oil, Lube Oil, and Starting Air 3.8.3 3.8 ELECTRICAL POWER SYSTEMS 3.8.3 Diesel Fuel Oil, Lube Oil, and Starting Air LCO

3.8.3 APPLICABILITY

The stored diesel fuel oil, lube oil, and starting air subsystem shall be within limits for each required diesel generator (DG).

When associated DG is required to be OPERABLE.

ACTIONS


NOTE--------------------------------

Separate Condition entry is allowed for each DG.

CONDITION REQUIRED ACTION COMPLETION TIME A.

One or more DGs with A.1 Restore fuel oil 48 hours5.555556e-4 days <br />0.0133 hours <br />7.936508e-5 weeks <br />1.8264e-5 months <br /> fuel volume < 48,400 level to within gallons and > 41,800 limits.

gallons in storage tank during MODE 1,2,3 or 4.

B.

One or more DGs with B.1 Restore lube oil 48 hours5.555556e-4 days <br />0.0133 hours <br />7.936508e-5 weeks <br />1.8264e-5 months <br /> lube oil inventory inventory to within

< TS min and > TS limits.

inop.

C.

One required DG with C.1 Restore fuel oil 48 hours5.555556e-4 days <br />0.0133 hours <br />7.936508e-5 weeks <br />1.8264e-5 months <br /> fuel volume in the level to within storage tank < 43,600 limits.

gallons and > 37,400 gallons during MODE 5 or 6.

D.

One or more DGs with 0.1 Restore fuel oil 7 days stored fuel oil total total particulates to particulates not within limits.

within limits.

(continued)

SAN ONOFRE--UNIT 2 3.8-20 Amendment No. 211

Diesel Fuel Oil, Lube Oil, and Starti ng Air 3.8.3 ACTIONS (continued)

CONDITION REQUIRED ACTION COMPLETION TIME E.

One or more DGs with E.1 Restore stored fuel 30 days new fuel oil oil properties to properties not within within limits.

limits.

F.

One or more DGs with F.1 Restore starting air 48 hours5.555556e-4 days <br />0.0133 hours <br />7.936508e-5 weeks <br />1.8264e-5 months <br /> starting air receiver receiver pressure to pressure-< 175 psig

Ž 175 psig.

and

Ž 136 psig.

G. Required Action and G.1 Declare associated DG Immediately associated Completion inoperable.

Time of Condition A, B, C, D, E or F not met.

OR One or more DGs with diesel fuel oil, lube oil, or starting air subsystem not within limits for reasons other than Condition A, B, C, D, E, or F.

SURVEILLANCE REQUIREMENTS SURVEILLANCE FREQUENCY SR 3.8.3.1 Verify each fuel oil storage tank contains 31 days 48,400 gallons in MODE 1,2,3 or 4 and 2 43,600 gallons in MODE 5 or 6.

(continued)

SAN ONOFRE--UNIT 2 3.8-21 Amendment No. 211

ECW System B 3.7.10 BASES (continued)

BACKGROUND (continued)

TABLE I Individual Room Coolers IE COOLER ME417 ME416 ME517 ME445 ME455 ME454 ME528 ME453 ME438 ME435 ME436 ME437 ME255 ME257 ME441 BACKUP COOLER ME414 ME413 ME445 (IE)

ME517 (TE)

ME448 ME450 (NON-lE) or ME518 ME450 (NON-lE) or ME454 ME449 RADWASTE FANS:

ME433 or ME434 (supply)

-AND-MA192 or MA193 (exhaust)

Same as above for ME438 ME437 (lE) or Same as above for ME438 ME436 (lE) or Same as above for ME438 ME430 and MA165, or alternate method ME430 and MA165, or alternate method ME442 (1E) or FUEL HANDLING BUILDING FANS:

MA359 or MA360 (supply)

-AND-MA316 or MA317 (exhaust)

EQUIPMENT IN ROOM

P017, P015, P012
P019, P016, P013 P018 P018 P026 P025 P025 P024 P190 P192 P191 P191 50 ft.

50 ft.

P009 swgr swgr (continued)

SAN ONOFRE--UNIT 2 B 3.7-51 Amendment No.

127 04/08/07 1

AC Sources-Operating B 3.8.1 BASES (continued)

SURVEILLANCE SR 3.8.1.4 (continued)

REQUIREMENTS full load plus iO%.

The level is expressed as an equivalent volume in inches.

The 31.5 inch level includes instrument uncertainties and corresponds to the minimum requirement of 389 gallons of fuel oil.

The 31 day Frequency is adequate to assure that a sufficient supply of fuel oil is available, since low level alarms are provided and unit operators would be aware of any large uses of fuel oil during this period.

SR 3.8.1.5 Microbiological fouling is a major cause of fuel oil degradation.

There are numerous microorganisms that can grow in fuel oil and cause fouling, but all must have a water environment in order to survive.

Removal of water from the fuel oil day tanks once every 31 days eliminates the necessary environment for microbial survival in the day tanks.

This is the most effective means of controlling microbiological fouling.

In addition, it eliminates the potential for water entrainment in the fuel oil during DG operation.

Water may come from any of several sources, including condensation, ground water, rain water, contaminated fuel oil, and from breakdown of the fuel oil by microorganisms.

Frequent checking for and removal of accumulated water minimizes fouling and provides data regarding the watertight integrity of the fuel oil system:

The Surveillance Frequencies are established by Regulatory Guide 1.137 (Ref.

10).

This SR is for preventive maintenance.

The presence of water does not necessarily represent failure of this SR provided the accumulated water is removed during the performance of this Surveillance.

SR 3.8.1.6 This Surveillance demonstrates that for each OPERABLE DG at least one fuel oil transfer pump operates and transfers fuel oil from its associated storage tank to its associated day tank.

This is required to support continuous operation of the standby power source.

This Surveillance provides assurance that at least one fuel oil transfer pump is

OPERABLE, the fuel oil piping system is intact, the fuel delivery piping is not obstructed, and the controls and control systems for the fuel transfer system are OPERABLE.

(continued)

SAN ONOFRE--UNIT 2 B 3.8-18 Amendment No.

211 04/05/07 1

Diesel Fuel Oil, Lube Oil, and Starting Air B 3.8.3 B 3.8 ELECTRICAL POWER SYSTEMS B 3.8.3 Diesel Fuel Oil, Lube Oil, and Starting Air BASES BACKGROUND Each diesel generator (DG) is provided with a storage tank having a fuel oil capacity sufficient to operate that diesel for a period of 7 days, while the DG is supplying maximum post loss of coolant accident load demand as discussed in the UFSAR, Section 9.5.4.2 (Ref.

1).

The maximum load demand is calculated assuming the maximum load demand is supplied by one DG.

This onsite fuel oil capacity is sufficient to operate the DGs for longer than the time to replenish the onsite supply from outside sources.

Fuel oil is transferred from storage tank to day tank by either of two transfer pumps associated with each storage tank.

Redundancy of pumps and piping precludes the failure.

of one pump, or the rupture of any pipe, valve, or tank to result in the loss of more than one DG.

All outside tanks,

pumps, and piping are located underground.

For proper operation of the standby DGs, it is necessary to ensure the proper quality of the fuel oil.

San Onofre has a Diesel Fuel Oil (DFO) testing program which ensures proper fuel oil quality.

The program includes purchasing, receipt testing of new fuel oil, and periodic analyses of the stored fuel.

San Onofre is not committed to the fuel analysis portion of Regulatory Guide 1.137 (Ref.

2) or ANSI N195-1976 (Ref.

3); however, these standards were utilized as guidance in the development of the DFO testing program.

The D G lubrication system is designed to provide sufficient lubrication to permit proper operation of its associated DG under all loading conditions.

The system is required to circulate the lube oil to the diesel engine working surfaces and to remove excess heat generated by friction during operation.

Each engine oil sump contains an inventory capable of supporting a minimum of 7 days of continuous operation.

This supply is sufficient supply to allow the operator to replenish lube oil from outside sources.

(continued)

SAN DNOFRE--UNIT 2 B 3.8-36 Amendment No.

211 04/05/07

Diesel Fuel Oil, Lube Oil, and Starting Air B 3.8.3 BASES (continued)

APPLICABILITY The AC sources (LCO 3.8.1 and LCO 3.8.2) are required to ensure the availability of the required power to shut down the reactor and maintain it in a safe shutdown condition after an AO0 or a postulated DBA.

Since stored diesel fuel oil, lube oil, and starting air subsystems support LCO 3.8.1 and LCO 3.8.2, stored diesel fuel oil, lube oil and starting air are required to be within limits when the associated DG is required to be OPERABLE.

ACTIONS A.I In this Condition, the 7 day fuel oil supply (48,400 gallons) for a DG is not available.

However, the Condition is restricted to fuel oil level reductions that maintain at least a 6 day supply (41,800 gallons).

These circumstances may be caused by events such as full load operation required after an inadvertent start while at minimum required level; or feed and bleed operations, which may be necessitated by increasing particulate levels or any number of other oil quality degradations.

This restriction allows sufficient time for obtaining the requisite replacement volume and performing the analyses required prior to addition of fuel oil to the tank.

A period of 48 hours5.555556e-4 days <br />0.0133 hours <br />7.936508e-5 weeks <br />1.8264e-5 months <br /> is considered sufficient to complete restoration of the required level prior to declaring the DG inoperable.

This period is acceptable based on the remaining capacity (> 6 days),

the fact that procedures will be initiated to obtain replenishment, and, the low probability of an event during this brief period.

B.1 With lube oil inventory less than the TSmin marking in the dipstick, sufficient lubricating oil to support 7 days of continuous DG operation at full load conditions may not be available.

However, the Condition is restricted to lube oil volume reductions that maintain at least a 6 day supply (continued)

SAN ONOFRE--UNIT 2 B 3.8-38 Amendment No.

211 04/05/07

Diesel Fuel Oil, Lube Oil, and Starting Air B 3.8.3 BASES (continued)

ACTIONS B.1 (continued) greater than or equal to the TSinop marking in the dipstick).

This restriction allows sufficient time to obtain the requisite replacement volume.

The TSmin mark corresponds to 369.4 gals for the 16 cylinder DG and 412.1 gals for the 20 cylinder DG.

The-TSinop mark corresponds to 347.5 gals for the 16 cylinder DG and 386.2 gals for the 20 cylinder DG.

A period of 48 hours5.555556e-4 days <br />0.0133 hours <br />7.936508e-5 weeks <br />1.8264e-5 months <br /> is considered sufficient to complete restoration of the required volume prior to declaring the DG inoperable.

This period is acceptable based on the remaining capacity (> 6 days),

the low rate of usage, the fact that procedures will be initiated to obtain replenishment, and the low probability of an event during this brief period.

C.1 In this Condition the 7 day fuel oil supply (43,600 gallons) for a DG during Mode 5 or 6 is not available.

However, the Condition is restricted to fuel oil level reductions that maintain at least a 6 day supply (37,400 gallons).

These circumstances may be caused by events such as full load operations required after an inadvertent start while at minimum required level; or feed and bleed operations, which may be necessitated by increasing particulate levels or any number of other oil quality degradations.

This restriction allows sufficient time for obtaining the requisite replacement volume and performing the analyses required prior to addition of fuel oil to the tank.

A period of 48 hours5.555556e-4 days <br />0.0133 hours <br />7.936508e-5 weeks <br />1.8264e-5 months <br /> is considered sufficient to complete restoration of the required level prior to declaring the DG inoperable.

This period is acceptable based on the remaining capacity

(> 6 days),

the fact that procedures will be initiated to obtain replenishment, and the low probability of an event during this brief period.

D.1 This Condition is entered as a result of a failure to meet the acceptance criterion of SR 3.8.3.3.

Normally, trending of particulate levels allows sufficient time to correct high particulate levels prior to reaching the limit of (continued)

SAN ONOFRE--UNIT 2 B 3.8-39 Amendment No.

211 04/05/07 1

Diesel Fuel Oil, Lube Oil, and Starting Air B 3.8.3 0

BASEIS (continued)

ACTIONS F.I (continued) are accomplished on the first attempt, and the low probability of an event during this brief period.

G.1 With a Required Action and associated Completion Time not met, or one or more DGs with diesel fuel oil or lube oil not within limits for reasons other than addressed by Conditions A through F, the associated DG may be incapable of performing its intended function and must be immediately declared inoperable.

SURVEILLANCE REQUIREMENTS SR 3.8.3.1 This SR provides verification that there is an adequate inventory of fuel oil (2 48,400 gallons in Mode 1, 2, 3, or 4 and > 43,600 gallons in Mode 5 or 6) in the storage tanks to support each DG's operation for 7 days at full load.

The 7 day period is sufficient time to place the unit in a safe shutdown condition and to bring in replenishment fuel from an offsite location.

The 31 day Frequency is adequate to ensure supply of fuel oil is available, since low provided and unit operators would be aware of fuel oil during this period.

that a sufficient level alarms are of any large uses SR 3.8.3.2 This Surveillance ensures that sufficient lube oil inventory is available to support at least 7 days of full load operation for each DG.

The TS min (412.1 gal for the 20 cylinder engine and 369.4 gal for the 16 cylinder engine) requirements are based on the DG Manufacturer consumption values for the run time of the DG.

(continued)

SAN ONOFRE--UNIT 2 B 3.8-41 Amendment No.

211 04/05/07

SONGS UNIT 3 SINGLE-SIDED Operating License & Technical Specification/Licensee Controlled Specification AMD 211/203, B05-010, & B06-002 Revise Unit 3 Operating License by removing pages and inserting the enclosed pages.

The revised pages are identified by the captioned amendment number and/or dates and contain marginal/lines indicating the areas of change. Please direct any questions regarding filing of information to: (949) 368-6557 or email CDM Controlled Manuals Desk.

REMOVE:

INSERT:

VOLUME 1 VOLUME 1 BEHIND: List of Effective Pages - "Blue Tab" BEHIND: List of Effective Pages - "Blue Tab" List of Effective Pages - Pages 1-12 3/07/07 List of Effective Pages - Pages 1-12 4/8/07 BEHIND: Facility Operating License "Blue Tab" BEHIND: Facility Operating License "Blue Tab" Facility Operating License Page 2 AMD 201 Facility Operating License Page 2 AMD 203 Page 3 AMD 201 Page 3 AMD 203 BEHIND: Electrical Power Systems "Blue Tab" BEHIND: Electrical Power Systems "Blue Tab" Page 3.8-6 AMD 170 Page 3.8-6 AMD 203 Page 3.8-20 AMD 174 Page 3.8-20 AMD 203 Page 3.8-21 AMD 174 Page 3.8-21 AMD 203 VOLUME 3 VOLUME 3 BEHIND: B 3.7 "Blue Tab" BEHIND: B 3.7 "Blue Tab" Page B 3.7-51 AMD 116 4/12/01 Page B 3.7-51 AMD 116 4/08/07 AL, BEHIND: B 3.8 - "Blue Tab" BEHIND: B 3.8 - "Blue Tab" F Page B 3.8-18 AMD 116 6/18/01 Page B 3.8-18 AMD 203 4/05/07 Page B 3.8-36 AMD 116 No Date Listed Page B 3.8-36 AMD 203 4/05/07 Page B 3.8-38 AMD 116 3/25/02 Page B 3.8-38 AMD 203 4/05/07 Page B 3.8-39 AMD 116 3/25/02 Page B 3.8-39 AMD 203 4/05/07 Page B 3.8-41 AMD 116 3/25/02 Page B 3.8-41 AMD 203 4/05/07 Filing Instructions Reviewed & Approved:

Signature/NRA Date Si'gnature/CDM Processor d ate Page 1 of 1

APPENDIX A TO LICENSE NO.

NPF-15 SAN ONOFRE UNIT 3 TECHNICAL SPECIFICATIONS (NUREG-0952)

LIST OF EFFECTIVE PAGES Page No.

Volume Amendment/Date Page No.

Volume Amendment/Date LOEP-1 1

203 04/08/07 2.0-1 1

199 LOEP-2 1

200 01/25/07 2.0-2 1

199 LOEP-3 1

203 04/04/07 3.0-1 1

116 LOEP-4 1

203 04/04/07 3.0-2 1

116 LOEP-4a 1

159 3.0-3 1

116 LOEP-5 1

199 12/21/06 3.0-4 1

177 LOEP-6 1

191 11/18/05 3.0-5 1

116 LOEP-7 1

188 07/19/05 3.1-1 1

191 LOEP-8 1

200 12/05/06 3.1-2 1

191 LOEP-9 1

196 09/19/06 3.1-3 1

191 LOEP-1O 1

188 04/08/07 3.1-4 1

116 LOEP-I1 1

203 04/05/07 3.1-5 1

116 LOEP-12 1

184 03/07/07 3.1-6 1

116 ii 1

116 3.1-7 1

191 iii 1

200 3.1-8 1

191 iv 1

200 3.1-9 1

116 v

1 188 3.1-10 1

116 vi 1

116 3.1-11 1

126 vii 1

200 3.1-12 1

191 viii 1

200 3.1-13 1

116 1.1-1 1

116 3.1-14 1

191 1.1-2 1

116 3.1-15 1

191 1.1-3 1

179 3.1-16 1

191 1.1-4 1

196 3.1-17 1

116 1.1-5 1

195 3.1-18 1

116 1.1-6 1

191 3.1-19 1

116 1.1-7 1

116 3.1-20 1

116 1.2-7 1

116 3.1-21 1

154 1.2-2 1

116 3.1-22 1

166 1.2-3 1

116 3.1-23 1

116 1.3-3 1

116 3.1-24 1

116 1.3-1 1

116 3.1-25 1

116 1.3-3 1

116 3.1-26 1

116 1.3-3 1

116 3.1-27 1

116 1.3-4 1

116 3.1-28 1

116 1.3-5 1

116 3.1-29 1

116 1.3-6 1

116 3.2-1 1

116 1.3-7 1

116 3.2-2 1

116 1.3-8 1

116 3.2-3 1

116 1.3-9 1

116 3.2-4 1

116 1.3-10 1

116 3.2-5 1

116 1.3-11 1

116 3.2-6 1

116 1.3-12 1

116 3.2-7 1

116 1.3-13 1

116 3.2-8 1

116 1.4-1 1

116 3.2-9 1

191 1.4-2 1

116 3.2-10 1

116 1.4-3 1

116 3.2-11 1

116 1.4-4 1

116 3.2-12 1

116 Page 1 of 12 Amendment 203 04/08/07

APPENDIX A TO LICENSE NO.

NPF-15 SAN ONOFRE UNIT 3 TECHNICAL SPECIFICATIONS (NUREG-0952)

LIST OF EFFECTIVE PAGES Page No.

Volume Amendment/Date Page No.

Volume Amendment/Date 3.3-1 3.3-2 3.3-3 3.3-4 3.3-5 3.3-6 3.3-7 3.3-8 3.3-9 3.3-10 3.3-11 3.3-12 3.3-13 3.3-14 3.3-15 3.3-16 3.3-17 3.3-18 3.3-19 3.3-20 3.3-21 3.3-22 3.3-23 3.3-24 3.3-25 3.3-26 3.3-27 3.3-28 3.3-29 3.3-30 3.3-31 3.3-32 3.3-33 3.3-34 3.3-35 3.3-36 3.3-37 3.3-38 3.3-39 3.3-40 3.3-41 3.3-42 3.3-43 3.3-44 3.3-45 3.3-46 3.3-47 3.3-48 3.3-49 116 116 116 116 116 139 122 142 142 116 116 122 139 116 116 122 116 116 116 122 116 148 148 148 148 116 116 116 122 116 116 116 116 187 121 121 121 121 121 166 151 200 200 116 185 185 185 116 116 3.3-50 3.3-51 3.3-52 3.4-1 3.4-2 3.4-3 3.4-4 3.4-5 3.4-6 3.4-7 3.4-8 3.4-9 3.4-10 3.4-11 3.4-12 3.4-13 3.4-14 3.4-15 3.4-16 3.4-17 3.4-18 3.4-19 3.4-20 3.4-21 3.4-22 3.4-23 3.4-24 3.4-25 3.4-26 3.4-27 3.4-28 3.4-29 3.4-30 3.4-31 3.4-32 3.4-33 3.4-34 3.4-35 3.4-36 3.4-37 3.4-38 3.4-39 3.4-40 3.4-41 3.4-42 3.4-43 3.4-44 3.4-45 116 166 116 141 141 141 116 195 195 195 195 195 195 195 195 116 188 116 166 166 195 166 116 166 195 166 166 166 152 146 147 147 195 195 116 195 134 195 116 196 196 116 116 116 116 116 116 116 01/25/07 01/25/07 Page 2 of 12 Amendment 200 01/25/07

APPENDIX A TO LICENSE NO.

NPF-15 SAN ONOFRE UNIT 3 TECHNICAL SPECIFICATIONS LIST OF EFFECTIVE PAGES (NUREG-0952)

Page No.

Volume Amendment/Date Page No.

Volume Amendment/Date 3.4-46 3.4-47 3.4-48 3.4-49 3.4-50 3.4-51 3.4-52 3.5-1 3.5-2 3.5-3 3.5-4 3.5-5 3.5-6 3.5-7 3.5-8 3.5-9 3.5-10 3.5-11 3.6-1 3.6-2 3.6-3 3.6-4 3.6-5 3.6-6 3.6-7 3.6-8 3.6-9 3.6-10 3.6-11 3.6-12 3.6-13 3.6-14 3.6-15 3.6-16 3.6-17 3.6-18 3.6-19 3.6-20 3.6-21 3.6-22 3.6-23 3.6-24 3.6-25 3.6-26 3.7-1 3.7-2 3.7-3 3.7-4 3.7-5 116 116 116 116 116 196 196 131 124 116 131 116 181 116 116 116 116 116 116 135 116 116 116 135 116 116 116 116 116 156 192 192 116 116 116 162 116 116 116 116 150 150 116 116 116 116 116 154 116 3.7-6 3.7-7 3.7-8 3.7-9 3.7-10 3.7-11 3.7-12 3.7-13 3.7-14 3.7-15 3.7-16 3.7-17 3.7-18 3.7-19 3.7-19a 3.7-19b 3.7-19c 3.7-20 3.7-21 3.7-22 3.7-23 3.7-24 3.7-25 3.7-26 3.7-27 3.7-28 3.7-29 3.7-30 3.7-31 3.7-32 3.7-33 3.7-34 3.7-35 3.8-1 3.8-2 3.8-3 3.8-4 3.8-5 3.8-6 3.8-7 3.8-8 3.8-9 3.8-10 3.8-11 3.8-12 3.8-13 3.8-14 3.8-15 3.8-16 116 116 116 116 116 155 116 116 182 139 153 116 116 116 118 118 118 116 116 172 116 172 168 168 200 200 116 116 116 120 120 120 116 133 133 116 149 170 203 149 170 149 149 149 149 160 170 149 116 01/25/07 01/25/07 Page 3 of 12 Amendment 203 04/04/07

APPENDIX A TO LICENSE NO.

NPF-15 SAN ONOFRE UNIT 3 TECHNICAL SPECIFICATIONS (NUREG-0952)

LIST OF EFFECTIVE PAGES Page No.

Volume Amendment/Date Page No.

Volume Amendment /Date 3.8-17 3.8-18 3.8-19 3.8-20 3.8-21 3.8-22 3.8-23 3.8-24 3.8-25 3.8-26 3.8-27 3.8-28 3.8-29 3.8-30 3.8-31 3.8-32 3.8-33 3.8-34 3.8-35 3.8-36 3.8-37 3.8-38 3.8-39 3.8-40 3.8-41 3.9-1 3.9-2 3.9-3 3.9-4 3.9-5 3.9-6 3.9-6a 3.9-7 3.9-8 3.9-9 3.9-9a 3.9-10 4.0-1 4.0-2 4.0-3 4.0-4 4.0-5 5.0-1 5.0-2 5.0-3 5.0-4 5.0-5 5.0-6 5.0-7 116 166 116 203 203 116 116 116 116 116 166 116 116 116 116 116 116 116 116 166 116 116 116 166 116 116 166 116 184 116 166 166 144 144 166 144 123 190 116 116 120 120 199 199 199 199 199 175 116 5.0-8 5.0-9 5.0-10 5.0-11 5.0-12 5.0-13 5.0-14 5.0-15 5.0-15a 5.0-16 5.0-17 5.0-18 5.0-19 5.0-20 5.0-20a 5.0-20b 5.0-21 5.0-22 5.0-23 5.0-24 5.0-25 5.0-26 5.0-27 5.0-27a 5.0-28 5.0-29 5.0-30

5. 0-31 199 169 116 161 169 196 196 198 198 196 200 196 196 196 189 135 116 116 186 116 116 191 195 195 196 196 188 199 Page 4 of 12 Amendment 203 04/04/07

APPENDIX A TO LICENSE NO.

NPF-15 SAN ONOFRE UNIT 3 TECHNICAL SPECIFICATIONS (NUREG-0952)

LIST OF EFFECTIVE PAGES Paqe No.

Bibliographic Data Sheet Appendix B Environmental Protection Plan 1-1 2-1 2-2 3-1 3-2 4-1 4-2 Appendix C Page 2 Page 3 Vol ume 1

1 1

1 1

1 1

1 1

1 Amendment/Date dated Nov.

15, dated Nov.

15, dated Nov.

15, dated Nov.

15, dated Nov.

15, dated Nov.

15, 159 159 dated Nov.

15, dated Nov.

15, dated Nov.

15, dated Nov.

15, 1982 1982 1982 1982 1982 1982 1982 1982 1982 1982 Page 4a of 12 Amendment 159

APPENDIX A TO LICENSE NO.

NPF-15 SAN ONOFRE UNIT 3 TECHNICAL SPECIFICATIONS (NUREG-0952)

LIST OF EFFECTIVE PAGES Page No.

Volume Amendment/Date Page No.

Volume Amendment/Date B 2.0-1 2

183 07/19/04 B 3.1-27 2

116 B 2.0-2 2

116 B 3.1-28 2

191 11/18/05 B 2.0-3 2

199 12/21/06 B 3.1-29 2

191 11/18/05 B 2.0-3a 2

183 07/19/04 B 3.1-30 2

191 11/18/05 B 2.0-4 2

199 12/21/06 B 3.1-31 2

116 B 2.0-5 2

199 12/21/06 B 3.1-32 2

116 05/02/97 B 2.0-6 2

116 B 3.1-33 2

116 B 2.0-7 2

116 B 3.1-34 2

116 05/02/97 B 2.0-8 2

199 12/21/06 B 3.1-35 2

116 B 2.0-9 2

199 12/21/06 B 3.1-36 2

116 B 3.0-1 2

116 B 3.1-37 2

191 11/18/05 B 3.0-2 2

116 B 3.1-38 2

191 11/18/05 B 3.0-3 2

116 B 3.1-39 2

116 B 3.0-4.

2 199 12/21/06 B 3.1-40 2

116 B 3.0-5 2

116 B 3.1-41 2

116 B 3.0-6 2

116 B 3.1-42 2

116 B 3.0-7 2

116 B 3.1-43 2

191 11/18/05 B 3.0-8 2

116 B 3.1-43a 2

191 11/18/05 B 3.0-9 2

116 B 3.1-44 2

191 11/18/05 B 3.0-10 2

116 B 3.1-45 2

116 B 3.0-11 2

116 B 3.1-46 2

191 11/18/05 B 3.0-12 2

116 12/01/98 B 3.1-47 2

116 B 3.0-13 2

177 10/25/02 B 3.1-48 2

116 B 3.0-14 2

177 05/08/02 B 3.1-49 2

116 B 3.0-15 2

177 05/08/02 B 3.1-50 2

116 B 3.1-1 2

191 11/18/05 B 3.1-51 2

116 B 3.1-2 2

191 11/18/05 B 3.1-52 2

116 B 3.1-3 2

191 11/18/05 B 3.1-53 2

116 B 3.1-4 2

191 11/18/05 B 3.1-54 2

116 08/03/01 B 3.1-5 2

Deleted B 3.1-55 2

116 08/03/01 B 3.1-6 2

Deleted B 3.1-56 2

116 08/03/01 B 3.1-7 2

191 11/18/05 B 3.1-57 2

116 08/03/01 B 3.1-8 2

191 11/18/05 B 3.1-58 2

116 08/03/01 B 3.1-9 2

191 11/18/05 B 3.1-58a 2

116 08/03/01 B 3.1-10 2

191 11/18/05 B 3.1-58b 2

116 08/03/01 B 3.1-11 2

Deleted B 3.1-59 2

191 11/18/05 B 3.1-12 2

Deleted B 3.1-60 2

116 11/05/96 B 3.1-13 2

116 B 3.1-61 2

116 05/03/00 B 3.1-14 2

116 B 3.1-62 2

166 12/20/00 B 3.1-15 2

191 11/18/05 B 3.1-63 2

166 05/21/02 B 3.1-16 2

116 B 3.1-63a 2

166 12/20/00 B 3.1-17 2

191 11/18/05 B 3.1-64 2

116 B 3.1-18 2

116 B 3.1-65 2

116 B 3.1-19 2

116 01/03/02 B 3.1-66 2

116 B 3.1-20 2

116 B 3.1-67 2

116 B 3.1-21 2

116 01/03/02 B 3.1-68 2

116 B 3.1-22 2

116 05/30/97 B 3.1-69 2

116 B 3.1-23 2

116 B 3.1-70 2

116 B 3.1-24 2

116 B 3.1-71 2

116 B 3.1-25 2

116 05/02/97 B 3.1-72 2

116 B 3.1-26 2

116 07/29/99 Page 5 of 12 Amendment 199 12/21/06

APPENDIX A TO LICENSE NO.

NPF-15 SAN ONOFRE UNIT 3 TECHNICAL SPECIFICATIONS LIST OF EFFECTIVE PAGES (NUREG-0952)

Page No.

Volume Amendment/Date PaQe No.

Volume Amendment/Date

3. 1-73 3.1-74
3.

1-75

3. 1-76
3.

1-77

3.

1-78 3.1-79 3.1-80 3.2-1 3.2-2 3.2-3 3.2-4 3.2-5 3.2-6 3.2-7 3.2-8 3.2-9 3.2-10 3.2-11 3.2-12 3.2-13 3.2-14 3.2-15 3.2-16 3.2-17 3.2-18 3.2-19 3.2-20 3.2-21 3.2-22 3.2-23 3.2-24 3.2-25 3.2-26 3.2-27 3.2-28 3.2-29 3.2-30 3.2-31 3.2-32 3.2-33 3.2-34 3.2-35 3.2-36 3.2-37 3.2-38 3.2-39 3.2-40 3.2-41 3.3-i 116 116 116 116 116 116 116 116 116 116 116 183 116 116 116 116 116 116 116 183 116 116 116 116 116 116 183 116 116 116 116 116 116 116 116 116 183 191 116 116 116 116 116 116 116 183 116 116 116 116 05/29/97 05/29/97 07/19/04

.07/19/04 3.3-2 3.3-3 3.3-4 3.3-5 3.3-6 3.3-7 3.3-8 3.3-9 3.3-10 3.3-1.1 3.3-12 3.3-13 3.3-14 3.3-15 3.3-16 3.3-17 3.3-18 3.3-19 3.3-20 3.3-21 3.3-22 3.3-23 3.3-24 3.3-25 3.3-26 3.3-26a 3.3-27 3.3-28 3.3-29 3.3-30 3.3-31 3.3-32 3.3-33 3.3-34 3.3-35 3.3-36 3.3-37 3.3-37a 3.3-38 3.3-39 3.3-40 3.3-41 3.3-42 3.3-43 3.3-44 3.3-45 3.3-46 3.3-47 3.3-48 3.3-49 116 116 116 116 116 116 116 116 116 116 116 116 116 116 116 116 116 116 116 116 116 116 116 116 116 116 116 116 116 116 116 116 116 116 116 116 179 179 116 116 116 116 116 116 116 116 116 116 116 116 07/17/97 03/12/99 07/17/97 09/16/03 03/12/99 03/12/99 03/12/99 03/12/99 12/30/96 12/30/96 12/30/96 05/29/97 05/02/97 03/12/99 03/12/99 03/12/99 03/12/99 03/12/99 09/16/03 07/17/97 12/09/98 12/09/98 12/30/96 12/30/96 12/30/96 12/30/96 09/18/98 09/18/98 07/19/104 07/19/04 11/18/05 07/19/04 Page 6 of 12 Amendment 191 11/18/05

APPENDIX A TO LICENSE NO.

NPF-15 SAN ONOFRE UNIT 3 TECHNICAL SPECIFICATIONS LIST OF EFFECTIVE PAGES (NUREG-0952)

Page No.

Volume Amendment/Date Page No.

Volume Amendment/Date 3.3-50 3.3-51 3.3-51a 3.3-52 3.3-53 3.3-54 3.3-55 3.3-56 3.3-57 3.3-58 3.3-59 3.3-60 3.3-61 3.3-62 3.3-63 3.3-64 3.3-65 3.3-66 3.3-67 3.3-68 3.3-69 3.3-70 3.3-71 3.3-72 3.3-73 3.3-74 3.3-75 3.3-76 3.3-77 3.3-78 3.3-79 3.3-80 3.3-81 3.3-82 3.3-83 3.3-84 3.3-85 3.3-86 3.3-87 3.3-88 3.3-89 3.3-90 3.3-91 3.3-92 3.3-93 3.3-94 3.3-95 3.3-96 3.3-97 3.3-98 3.3-99 116 116 116 116 116 116 116 116 116 116 116 116 116 116 116 116 116 116 116 116 116 116 116 116 116 116 116 116 116 116 116 116 116 116 116 116 116 116 116 116 116 116 116 116 116 116 116 116 116 116 116 09/18/98 02/11/02 09/18/98 07/17/97 09/18/98 09/18/98 09/18/98 07/17/97 12/30/96 12/30/96 12/30/96 05/28/97 12/30/96 07/17/97 3.3-100 3.3-101 3.3-102 3.3-103 3.3-103a 3.3-103b 3.3-103c 3.3-104 3.3-105 3.3-106 3.3-107 3.3-108 3.3-109 3.3-110 3.3-111 3.3-112 3.3-113 3.3-114 3.3-115 3.3-116 3.3-117 3.3-118 3.3-119 3.3-120 3.3-121 3.3-122 3.3-123 3.3-124 3.3-125 3.3-126 3.3-127 3.3-128 3.3-129 3.3-130 3.3-131 3.3-132 3.3-133 3.3-134 3.3-135 3.3-136 3.3-137 3.3-138 3.3-139 3.3-140 3.3-141 3.3-142 3.3-143 3.3-144 3.3-145 3.3-146 188 116 116 116 179 148 179 116 116 116 116 116 116 116 116 116 116 116 116 116 116 116 116 116 116 116 116 116 116 116 116 116 116 116 116 116 116 165 116 116 116 116 116 116 116 116 116

.116 116 116 07/19/05 10/06/99 10/06/99 10/06/99 09/16/03 12/30/96 12/30/96 12/30/96 12/30/96 05/28/97 05/28/97 05/28/97 09/06/00 09/06/00 05 /29/97 07/13/99 12/14/00 05 /28/ 97 06/09/00 05/28/ 97 05/28/ 97 05/28/ 97 05 /28/ 97 05/28/97 05 /28/97 05/28/97 05/28/97 06/27/97 03/19/98 02/24/99 07/17/97 10/06/99 10/06/99 10/06/99 07/18/01 10/06/99 Page 7 of 12 Amendment 188 07/19/05

APPENDIX A TO LICENSE NO.

NPF-15 SAN ONOFRE UNIT 3 TECHNICAL SPECIFICATIONS (NUREG-0952)

LIST OF EFFECTIVE PAGES Page No.

Volume Amendment/Date Page No.

Volume Amendment/Date 3.3-147 3.3-148 3.3-149 3.3-150 3.3-151 3.3-152 3.3-153 3.3-154 3.3-155 3.3-156 3.3-157 3.3-158 3.3-159 3.3-160

3. 3-161 3.3-162
3. 3-163 3.3-164 3.3-165 3.3-166 3.3-167 3.3-168 3.3-169 3.3-170 3.3-171 3.3-172 3.3-173 3.3-174 3.3-175 3.3-176 3.3-177 3.3-178 3.3-179 3.3-180 3.3-181 3.3-182 3.3-183 3.3-184 3.3-185 3.4-1 3.4-2 3.4-3 3.4-4 3.4-5 3.4-6 3.4-7 3.4-8 3.4-9 3.4-10 3.4-11 116 166 166 116 116 200 200 200 200 200 200 116 116 116 116 116 119 116 116 185 116 116 116 116 185 185 116 116 116 116 116 116 116 116 116 166 166 166 166 116 116 116 116 116 116 116 116 195 116 116 06/27/97 12/20/00 12/20100 08/20/01 06/27/97 12/05/06 12/05/06 12/05/06 12/05/06 12/05/06 12/05/06 12/17/98 06/08/00 06/2 3/99 05/30/97 05/30/97 05/30/97 05/3,0/97 05/3 0/97 04/25/05 05/3,0/97 12/02/99 05/30/97 04/25/05 04/25/05 05/30/97 05/30/97 03/06/06 10/30/98 10/30/98 04/24/01 04/24/001 07/29/96 12/20/00 12/20/00 12/20/00 12/20/100 02/24/99 02/24/99 02/24/99 3.4-12 3.4-13 3.4-14 3.4-15 3.4-16 3.4-17 3.4-18 3.4-19 3.4-20 3.4-21 3.4-22 3.4-23 3.4-24 3.4-25 3.4-26 3.4-27 3.4-28 3.4-29 3.4-30 3.4-31 3.4-32 3.4-33 3.4-34 3.4-35 3.4-36 3.4-37 3.4-38 3.4-38a 3.4-39 3.4-40 3.4-41 3.4-42 3.4-43 3.4-44 3.4-45 3.4-46 3.4-47 3.4-48 3.4-49 3.4-50 3.4-51 3.4-52 3.4-53 3.4-54 3.4-55 3.4-56 3.4-57 3.4-58 3.4-59 3.4-60 3

3 3

3 3

3 3

3 3

3 3

3 3

3 3

3 3

3 3

3 3

3 3

3 3

3 3

3 3

3 3

3 3

3 3

3 3

3 3

3 3

3 3

3 3

3 3

3 3

3 116 116 116 195 195 188 188 116 188 188 116 116 196 116 116 116 196 166 166 116 196 116 166 166 116 166 166 166 196 166 116 116 166 166 166 116 146 152 116 116 147 147 147 147 195 195 195 195 195 195 07/19/05 07/19/05 07/19/05 07/19/05 12/20/00 12/20/00 12/20/00 12/20/00 12/20/00 07/15/05 04/03/06 12/20/00 12/20/00 04/03/06 12/20/00 05/30/00 05/30/00 05/15/02 05/30/00 05/30/00 03/22/01 03/22/01 03/22/01 04/27/05 Page 8 of 12 Amendment 200 12/05/06

APPENDIX A TO LICENSE NO.

NPF-15 SAN ONOFRE UNIT 3 TECHNICAL SPECIFICATIONS (NUREG-0952)

LIST OF EFFECTIVE PAGES Page No.

Volume Amendment/Date Page No.

Volume Amendment/Date 3.4-61 3.4-62 3.4-63 3.4-64 3.4-65 3.4-66 3.4-67 3.4-68 3.4-69 3.4-70 3.4-71 3.4-72 3.4-73 3.4-74 3.4-75 3.4-76 3.4-77 3.4-78 3.4-79 3.4-80 3.4-81 3.4-82 3.4-83 3.4-84 3.4-85 3.4-86 3.4-87 3.4-88 3.4-89 3.4-90 3.4-91 3.4-92 3.4-93 3.4-94 3.4-95 3.4-96 3.4-97 3.4-98 3.4-99 3.4-100 3.5-1 3.5-2 3.5-3 3.5-4 3.5-5 3.5-6 3.5-7 3.5-8 3.5-9 3.5-10 3.5-10a 195 195 195 195 195 195 195 195 195 116 196 196 196 196 196 116 116 116 116 116 116 116 116 116 116 116 116 116 116 116 116 116 196 196 196 196 196 196 196 196 116 116 116 116 116 116 116 188 116 116 188 09/06/00 09/06/00 3.5-11 3.5-12 3.5-13 3.5-14 3.5-15 3.5-16 3.5-17 3.5-18 3.5-19 3.5-20 3.5-20a 3.5-21 3.5-22 3.5-23 3.5-24 3.5-25 3.5-26 3.5-27 3.5-28 3.5-29 3.5-30 3.5-31 3.5-32 3.5-33 3.5-34 3.6-1 3.6-2 3.6-3 3.6-4 3.6-5 3.6-6 3.6-7 3.6-8 3.6-9 3.6-10 3.6-11 3.6-12 3.6-13 3.6-14 3.6-15 3.6-16 3.6-17 3.6-18 3.6-19 3.6-20 3.6-21 3.6-22 3.6-23 3.6-24 3.6-24a 3.6-25 116 116 116 116 116 188 116 116 116 116 116 116 116 116 116 116 116 116 116 116 116 116 116 116 116 116 173 116 116 116 173 116 116 116 116 116 116 116 116 116 116 116 116 116 116 116 116 192 192 192 116 03/03/00 03/03/00 03/03/00 03/03/00 03/03/00 07/19/05 03/03/00 03/14/02 03/14/02 07/17/01 03/03/00 12/01/98 08/06/03 08/06/03 04/29/03 12/01/98 02/11/02 12/01/98 04/29/03 07/29/99 04/29/03 06/09/00 04/29/03 10/24/01 12/12/05 12/12/05 12/12/05 04/29/03 05/13/02 05/13/02 05/05/03 05/30/97 07/15/98 07/19/05 07/15/98 07/15/98 07/19/05 Page 9 of 12 Amendment 196 09/19/06

APPENDIX A TO LICENSE NO.

NPF-15 SAN ONOFRE UNIT 3 TECHNICAL SPECIFICATIONS (NUREG-0952)

LIST OF EFFECTIVE PAGES Page No.

Volume Amendment/Date Page No.

Volume Amendment/Date 3.6-26 3.6-27 3.6-28 3.6-29 3.6-30 3.6-31 3.6-32 3.6-33 3.6-34 3.6-35 3.6-36 3.6-37 3.6-38 3.6-39 3.6-40 3.6-41 3.6-42 3.6-43 3.6-44 3.6-45 3.6-46 3.6-47 3.6-48 3.6-49 3.6-50 3.6-51 3.6-52 3.6-53 3.6-54 3.6-55 3.6-56 3.6-57

3. 7-1 3.7-2 3.7-3 3.7-4 3.7-5 3.7-6 3.7-7 3.7-8 3.7-9 3.7-10 3.7-11 3.7-12 3.7-13 3.7-14 3.7-15 3.7-16 3.7-17 3.7-18 3.7-19 116 173 173 116 116 173 116 116 116 173 173 188 188 116 116 116 116 116 116 116 116 116 150 150 150 150 150 150 150 150 150 150 116 116 116 116 116 116 116 116 116 116 116 116 116 116 116 116 116 116 116 04/29/03 07/11/02 02/11/02 04/29/03 05/02/02 02/11/02 02/11/02 07/19/05 07/19/05 10/06/00 10/06/00 10/06/00 04/29/03 10/29/99 10/29/99 10/29/99 10/29/99 10/29/99 10/06/00 10/06/00 10/29/99 10/29/99 10/29/99 08/13/01 08/18/98 08/18/98 04/16/99 06/23/99 3.7-20 3.7-21 3.7-22 3.7-23 3.7-24 3.7-25 3.7-26 3.7-27 3.7-28 3.7-29 3.7-30 3.7-31 3.7-32 3.7-33 3.7-34 3.7-35 3.7-36 3.7-37 3.7-38 3.7-39 3.7-40 3.7-41 3.7-42 3.7-43 3.7-43a 3.7-43b 3.7-43c 3.7-43d 3.7-43e 3.7-43f 3.7-43g 3.7-43h 3.7-43i 3.7-43j 3.7-44 3.7-45 3.7-46 3.7-47 3.7-48 3.7-49 3.7-50 3.7-50a 3.7-51 3.7-52 3.7-53 3.7-54 3.7-55 3.7-55a 3.7-56 3.7-57 3.7-58 116 116 116 116 116 116 116 116 116 116 116 182 182 182 116 116 116 116 116 116 116 116 116 116 116 116 118 118 118 118 118 118 118 118 116 116 116 116 116 116 188 188 116 116 116 116 116 116 116 116 116 06/02/04 06/02/04 06/02/04 01/05/01 12/14/00 02/28/01 02/28/01 03/03/00 03/03/00 03/03/00 11/25/03 11/25/03 11/25/03 03/03/00 03/02/01 07/31/00 08/13/01 08 /01/01 06/23/99 04/03/06 05/29/97 07/29/96 05/30/97 10/17/01 03/07/07 03/07/07 04/08/07 10/17/01 04/12/01 04/12/01 03/07/07 03/07/07 06/28/99 04/25/05 03/19/98 04/16/99 06/02/04 Page 10 of 12 Amendment 188 04/08/07

APPENDIX A TO LICENSE NO.

NPF-15 SAN ONOFRE UNIT 3 TECHNICAL SPECIFICATIONS (NUREG-0952)

LIST OF EFFECTIVE PAGES Page No.

Volume Amendment/Date Page No.

Volume Amendment/Date 3.7-59 3.7-60 3.7-61 3.7-62 3.7-62a 3.7-63 3.7-64 3.7-65 3.7-66 3.7-67 3.7-68 3.7-69 3.7-70 3.7-71 3.7-72 3.7-73 3.7-74 3.7-75 3.7-76 3.7-77 3.7-78 3.7-79 3.8-1 3.8-2 3.8-3 3.8-4 3.8-5 3.8-6 3.8-7 3.8-7a 3.8-8 3.8-9 3.8-10 3.8-11 3.8-12 3.8-13 3.8-14 3.8-15 3.8-16 3.8-17 3.8-18 3.8-19 3.8-20 3.8-21 3.8-22 3.8-23 3.8-24 3.8-25 3.8-26 3.8-27 3.8-28 117 116 117 117 117 200 200 200 200 200 116 116 116 116 116 116 116 116 116 116 116 116 116 116 116 116 116 116 188 116 116 116 188 116 116 116 116 116 116 116 203 116 116 116 116 116 116 116 116 116 116 02/05/01 10/17/01 09/16/03 02/05/01 02/05/01 12/05/06 12/05/06 12/05/06 12/05/06 12/05/06 10/13/98 10/13/98 10/13/98 04/29/03 04/29/03 04/29/03 05/13/02 10/06/ 99 10/06/99 10/06/999 10/06/99 10/06 /99 10/06/999 07/19/05 12/10/999 10/06/99 10/06/999 07/19/005 10/06/99 10/06/999 10/06/ 99 10/06/999 10/06/999 06/18/01 06/18/ 01 04/055/07 06/18/01 06/18/001 06/18/01 06/18/01 06/18/01 06/18/01 06/18/01 06/18/01 06/18/01 06/18/01 3.8-29 3.8-29a 3..8-29b 3.8-29c 3.8-29d 3.8-29e 3.8-29f 3.8-30 3.8-31 3.8-32 3.8-33 3.8-34 3.8-35 3.8-36 3.8-37 3.8-38 3.8-39 3.8-40 3.8-41 3.8-42 3.8-43 3.8-44 3.8-45 3.8-46 3.8-47 3.8-47a 3.8-48 3.8-49 3.8-50 3.8-51 3.8-52 3.8-53 3.8-54 3.8-55 3.8-55a 3.8-56 3.8-57 3.8-58 3.8-59 3.8-60 3.8-61 3.8-62 3.8-63 3.8-64 3.8-65 3.8-66 3.8-67 3.8-68 3.8-69 3.8-70 3.8-71 3

3 3

3 3

3 3

3 3

3 3

3 3

3 3

3 3

3 3

3 3

3 3

3 3

3 3

3 3

3 3

3 3

3 3

3 3

3 3

3 3

3 3

3 3

3 3

3 3

3 3

116 160 160 160 160 160 160 116 116 116 116 166 166 203 116 203 203 116 203 116 116 116 116 116 116 116 116 116 116 116 116 116 116 116 116 116 116 166 166 116 116 116 116 116 116 116 116 116 116 116 116 06/18/01 06/ 18/01 06/18/01 06/18/01 06/18/01 06/18/01 06/ 18/01 12/20/00 12/20/00 04/05/07 01/21/98 04/05/07 04/05/07 01/21/98 04/05/07 03/25/02 03/25/02 05/03/00 01/22/99 01/22/99 01/22/99 01/22/99 08/05/98 08/30/04 08/05/98 12/20/00 12/20/00 07/31/00 Page 11 of 12 Amendment 203 04/05/07

APPENDIX A TO LICENSE NO.

NPF-15 SAN ONOFRE UNIT 3 TECHNICAL SPECIFICATIONS (NUREG-0952)

LIST OF EFFECTIVE PAGES Page No.

Volume Amendment/Date Page No.

Volume Amendment/Date 3.8-72 3.8-73 3.8-74 3.8-75 3.8-76 3.8-77 3.8-78 3.8-79 3.8-80 3.8-81 3.8-82 3.8-83 3.8-84 3.8-85 3.8-86 3.8-87 3.9-1 3.9-2 3.9-3 3.9-4 3.9-5 3.9-6 3.9-7 3.9-8 3.9-9 3.9-10 3.9-11 3.9-12 3.9-13 3 9-13a 3.9-14 3.9-15 3.9-16 3.9-17 3-9-17a 3.9-18 3.9-19 3.9-20 3.9-21 3.9-22 3.9-23 3.9-24 3.9-24a 3.9-25 3.9-26 3.9-27 116 166 166 116 116 116 116 116 116 116 116 116 116 116 166 166 116 116 166 116 116 166 116 116 116 184 116 116 184 184 116 116 116 116 116 166 166 116 116 116 116 166 166 116 116 116 12/20/00 12/20/00 01/11/07 12/20/00 12/20/00 12/20/00 12/20/00 12/01/98 02/18/05 10/10/97 10/10/97 02/18/05 02/18/05 10/10/97 10/10/97 07/15/05 04/03/06 07/15/05 12/20/00 05/30/97 07/15/05 04/03/06 12/20/00 12/20/00 05/30/97 10/13/98 10/13/98 Page 12 of 12 Amendment 184 03/07/07 SAN ONOFRE UNIT 3 FACILITY OPERATING LICENSE LIST OF EFFECTIVE PAGES Facility Operatinq License Page No.

Amendment No.

1 2

3 4

5 6

7 8

176 201 203 176 176 176 197 176 (3) SCE, pursuant to the Act and 10 CFR Part 70, to receive, possess, and use at any time special nuclear material as reactor fuel, in accordance with the limitations for storage and amounts required for reactor operation, as described in the Final Safety Analysis

Report, as supplemented and amended; (4) SCE, pursuant to the Act and 10 CFR Parts 30, 40, and 70, to receive, possess, and use at any time any byproduct, source and special nuclear materials as sealed neutron sources for reactor startup, sealed sources for reactor instrumentation and radiation monitoring equipment calibration, and as fission detectors in amounts as required; (5) SCE, pursuant to the Act and 10 CFR Parts 30, 40, and 70 to receive, possess, and use in amounts as required any byproduct, source or special nuclear material without restriction to chemical or physical form, for sample analysis or instrument calibration or associated with radioactive apparatus or components; and (6)

SCE, pursuant to the Act and 10 CFR Parts 30, 40, and 70, to possess, but not separate, such byproduct and special nuclear materials as may be produced by the operation of San Onofre Nuclear Generating Station, Units I and 3 and by the decommissioning of San Onofre Nuclear Generating Station Unit 1.

C.

This license shall be deemed to contain and is subject to the conditions specified in the Commission's regulations set forth in 10 CFR Chapter I and is subject to all applicable provisions of the Act and to the rules, regulations and orders of the Commission now or hereafter in effect; and is subject to the additional conditions specified or incorporated below:

(1) Maximum Power Level Southern California Edison Company (SCE) is authorized to operate the facility at reactor core power levels not in excess of full power (3438 megawatts thermal)

(2)

Technical Specifications The Technical Specifications contained in Appendix A and the Environmental Protection Plan contained in Appendix B, as revised through Amendment No.

203, are hereby incorporated in the license.

Southern California Edison Company shall operate the facility in accordance with the Technical Specifications and the Environmental Protection Plan.

Amendment No.

203

AC Sources -Operating 3.8.1 SURVEILLANCE REQUIREMENTS (continued)

SURVEILLANCE FREQUENCY SR 3.8.1.3


NOTES----------------

1.

DG loadings may include gradual loading as recommended by the manufacturer.

2.

Momentary transients outside the load range do not invalidate this test.

3.

This Surveillance shall be conducted on only one DG at a time.

4.

This SR shall be preceded by, and immediately follow without shutdown, a successful performance of SR 3.8.1.2 or SR 3.8.1.7.

5.

To ensure Operability of an AVR, it must have been aligned to the DG during the performance of SR 3.8.1.2 and SR 3.8.1.3 within the last 60 days, plus any allowance per SR 3.0.2.

Verify each DG is synchronized and loaded, and operates for Ž 60 minutes at a load

Ž 4450 kW and < 4700 kW.

As specified in Table 3.8.1-1 SR 3.8.1.4 Verify each day tank contains 2 31.5 inches 31 days of fuel oil.

SR 3.8.1.5 Check for and remove accumulated water from 31 days each day tank.

SR 3.8.1.6 Verify the fuel oil transfer system 31 days operates to transfer fuel oil from storage tank to the day tank.

(continued)

SAN ONOFRE--UNIT 3 3.8-6 Amendment No. 203

Diesel Fuel Oil, Lube Oil, and Starting Air 3.8.3 3.8 ELECTRICAL POWER SYSTEMS 3.8.3 Diesel Fuel Oil, Lube Oil, and Starting Air LCO

3.8.3 APPLICABILITY

The stored diesel fuel oil, lube oil, and starting air subsystem shall be within limits for each required diesel generator (DG).

When associated DG is required to be OPERABLE.

ACTIONS NOTE--------------------------------

Separate Condition entry is allowed for each DG.

CONDITION REQUIRED ACTION COMPLETION TIME A.

One or more DGs with A.1 Restore fuel oil 48 hours5.555556e-4 days <br />0.0133 hours <br />7.936508e-5 weeks <br />1.8264e-5 months <br /> fuel volume < 48,400 level to within gallons and > 41,800 limits.

gallons in storage tank during MODE 1,2,3 or 4.

B.

One or more DGs with B.1 Restore lube oil 48 hours5.555556e-4 days <br />0.0133 hours <br />7.936508e-5 weeks <br />1.8264e-5 months <br /> lube oil inventory inventory to within

< TS min and

Ž TS limits.

inop.

C.

One required DG with C.1 Restore fuel oil 48 hours5.555556e-4 days <br />0.0133 hours <br />7.936508e-5 weeks <br />1.8264e-5 months <br /> fuel volume in the level to within storage tank < 43,600 limits.

gallons and > 37,400 gallons during MODE 5 or 6.

D.

One or more DGs with D.1 Restore fuel oil 7 days stored fuel oil total total particulates to particulates not within limits.

within limits.

(continued)

SAN ONOFRE--UNIT 3 3.8-20 Amendment No. 203

Diesel Fuel Oil, Lube Oil, and Starting Air 3.8.3 ACTIONS (continued)

CONDITION REQUIRED ACTION COMPLETION TIME E.

One or more DGs with E.1 Restore stored fuel 30 days new fuel oil oil properties to properties not within within limits.

limits.

F.

One or more DGs with F.1 Restore starting air 48 hours5.555556e-4 days <br />0.0133 hours <br />7.936508e-5 weeks <br />1.8264e-5 months <br /> starting air receiver receiver pressure to pressure < 175 psig

Ž 175 psig.

and

Ž 136 psig.

G.

Required Action and G.1 Declare associated DG Immediately associated Completion inoperable.

Time of Condition A, B, C, D, E or F not met.

OR One or more DGs with diesel fuel oil, lube oil, or starting air subsystem not within limits for reasons other than Condition A, B, C, D, E, or F.

SURVEILLANCE REQUIREMENTS SURVEILLANCE FREQUENCY SR 3.8.3.1 Verify each fuel oil storage tank contains 31 days

Ž 48,400 gallons in MODE 1,2,3 or 4 and

Ž 43,600 gallons level in MODE 5 or 6.

(continued)

SAN ONOFRE--UNIT 3 3.8-21 Amendment No. 203 1

ECW System B 3.7.10 BASES (continued)

BACKGROUND (continued)

TABLE I Individual Room Coolers lE COOLER ME417 ME416 ME517 ME445 ME455 ME454 ME518 ME453 ME438 BACKUP COOLER ME414 ME413 ME445 (1E)

ME517 (1E)

ME448 ME450 (NON-IE) or ME518 ME450 (NON-lE) or ME454 ME449 RADWASTE FANS:

ME433 or ME434 (supply)

-AND-EOUIPMENT IN ROOM

P017, P015, P012
P019, P016, P013 P018 P018 P026 P025 P025 P024 P190 ME435 ME436 ME437 ME255 ME257 ME441 MA192 or MA193 (exhaust)

Same as above for ME438 ME437 (lE) or Same as above for ME438 ME436 (IE) or Same as above for ME438 ME430 and MA165, or alternate method ME430 and MA165, or alternate method ME442 (IE) or FUEL HANDLING BUILDING FANS:

MA359 or MA360 (supply)

-AND-MA316 or MA317 (exhaust)

P192 P191 P191 50 ft.

50 ft.

P009 swgr swgr (conti nued)

SAN ONOFRE--UNIT 3 B 3.7-51 Amendment No.

116 04/08/07 1

AC Sources-Operating B 3.8.1 BASES (continued)

SURVEILLANCE SR 3.8.1.4 (continued)

REQUIREMENTS full load plus 10%.

The level is expressed as an equivalent volume in inches.

The 31.5 inch level includes instrument uncertainties and corresponds to the minimum requirement of 389 gallons of fuel oil.

The 31 day Frequency is adequate to assure that a sufficient supply of fuel oil is available, since low level alarms are provided and unit operators would be aware of any large uses of fuel oil during this period.

SR 3.8.1.5 Microbiological fouling is a major cause of fuel oil degradation.

There are numerous microorganisms that can grow in fuel oil and cause fouling, but all must have a water environment in order to survive.

Removal of water from the fuel oil day tanks once every 31 days eliminates the necessary environment for microbial survival in the day tanks.

This is the most effective means of controlling microbiological fouling.

In addition, it eliminates the potential for water entrainment in the fuel oil during DG operation.

Water may come from any of several sources, including condensation, groundwater, rain water, contaminated fuel oil, and from breakdown of the fuel oil by microorganisms.

Frequent checking for and removal of accumulated water minimizes fouling and provides data regarding the watertight integrity of the fuel oil system.

The Surveillance Frequencies are established by Regulatory Guide 1.137 (Ref.

10).

This SR is for preventive maintenance.

The presence of water does not necessarily represent failure of this SR provided the accumulated water is removed during the performance of this Surveillance.

SR 3.8.1.6 This Surveillance demonstrates that for each OPERABLE DG at least one fuel oil transfer pump operates and transfers fuel oil from its associated storage tank to its associated day tank.

This is required to support continuous operation of the standby power source.

This Surveillance provides assurance that at least one fuel oil transfer pump is

OPERABLE, the fuel oil piping system is intact, the fuel delivery piping is not obstructed, and the controls and control systems for the fuel transfer system are OPERABLE.

(continued)

SAN ONOFRE--UNIT 3 B 3.8-18 Amendment 203 04/05/07

Diesel Fuel Oil, Lube Oil, and Starting Air B 3.8.3 B 3.8 ELECTRICAL POWER SYSTEMS B 3.8.3 Diesel Fuel Oil, Lube Oil, and Starting Air BASES BACKGROUND Each diesel generator (DG) is provided with a storage tank having a fuel oil capacity sufficient to operate that diesel for a period of 7 days, while the DG is supplying maximum post loss of coolant accident load demand as discussed in the UFSAR, Section 9.5.4.2 (Ref.

1).

The maximum load demand is calculated assuming the maximum load demand is supplied by one DG.

This onsite fuel oil capacity is sufficient to operate the DGs for longer than the time to replenish the onsite supply from outside sources.

Fuel oil is transferred from storage tank to day tank by either of two transfer pumps associated with each storage tank.

Redundancy of pumps and piping precludes the failure of one pump, or the rupture of any pipe, valve, or tank to result in the loss of more than one DG.

All outside tanks,

pumps, and piping are located underground.

For proper operation of the standby DGs, it is necessary to ensure the proper quality of the fuel oil.

San Onofre has a Diesel Fuel Oil (DFO) testing program which ensures proper fuel oil quality.

The program includes purchasing, receipt testing of new fuel oil, and periodic analyses of the stored fuel.

San Onofre is not committed to the fuel analysis portion of Regulatory Guide 1.137 (Ref.

2) or ANSI N195-1976 (Ref.

3); however, these standards were utilized as guidance in the development of the DFO testing program.

The DG lubrication system is designed to provide sufficient lubrication to permit proper operation of its associated DG under all loading conditions.

The system is required to circulate the lube oil to the diesel engine working surfaces and to remove excess heat generated by friction during operation.

Each engine oil sump contains an inventory capable of supporting a minimum of 7 days of continuous operation.

This supply is sufficient supply to allow the operator to replenish lube oil from outside sources.

(continued)

SAN ONOFRE--UNIT 3 B 3.8-36 Amendment No.

203 04/05/07 1

Diesel Fuel Oil, Lube Oil, and Starting Air B 3.8.3 BASES (Continued)

APPLICABILITY The AC sources (LCO 3.8.1 and LCO 3.8.2) are required to ensure the availability of the required power to shut down the reactor and maintain it in a safe shutdown condition after an AOO or a postulated DBA.

Since stored diesel fuel

oil, lube oil, and starting air subsystems support LCO 3.8.1 and LCO 3.8.2, stored diesel fuel oil, lube oil and starting air are required to be within limits when the associated DG is required to be OPERABLE.

ACTIONS A.1 In this Condition, the 7 day fuel oil supply (48,400 gallons) for a DG is not available.

However, the Condition is restricted to fuel oil level reductions that maintain at least a 6 day supply (41,800 gallons).

These circumstances may be caused by events such as full load operation required after an inadvertent start while at minimum required level; or feed and bleed operations, which may be necessitated by increasing particulate levels or any number of other oil quality degradations.

This restriction allows sufficient time for obtaining the requisite replacement volume and performing the analyses required prior to addition of fuel oil to the tank.

A period of 48 hours5.555556e-4 days <br />0.0133 hours <br />7.936508e-5 weeks <br />1.8264e-5 months <br /> is considered sufficient to complete restoration of the required level prior to declaring the DG inoperable.

This period is acceptable based on the remaining capacity (> 6 days),

the fact that procedures will be initiated to obtain replenishment, and the low probability of an event during this brief period.

B.1 With lube oil inventory less than the TSmin marking in the dipstick, sufficient lubricating oil to support 7 days of continuous DG operation at full load conditions may not be available.

However, the Condition is restricted to lube oil volume reductions that maintain at least a 6 day supply (continued)

SAN ONOFRE--UNIT 3 B 3.8-38 Amendment No.

203 04/05/07

Diesel Fuel Oil, Lube Oil, and Starting Air B 3.8.3 BASES (continued)

ACTIONS B.1 (continued) greater than or equal to the TSinop marking in the dipstick).

This restriction allows sufficient time to obtain the requisite replacement volume.

The TSmin mark corresponds to 369.4 gals for the 16 cylinder DG and 412.1 gals for the 20 cylinder DG.

The TSinop mark corresponds to 347.5 gals for the 16 cylinder DG and 386.2 gals for the 20 cylinder DG.

A period of 48 hours5.555556e-4 days <br />0.0133 hours <br />7.936508e-5 weeks <br />1.8264e-5 months <br /> is considered sufficient to complete restoration of the required volume prior to declaring the DG inoperable.

This period is acceptable based on the remaining capacity (> 6 days),

the low rate of usage, the fact that procedures will be initiated to obtain replenishment, and the low probability of an event during this brief period.

C.1 In this Condition the 7 day fuel oil supply (43,600 gallons) for a DG during Mode 5 or 6 is not available.

However, the Condition is restricted to fuel oil level reductions that maintain at least a 6 day supply (37,400 gallons).

These circumstances may be caused by events such as full load operations required after an inadvertent start while at minimum required level; or feed and bleed operations, which may be necessitated by increasing particulate levels or any number of other oil quality degradations.

This restriction allows sufficient time for obtaining the requisite replacement volume and performing the analyses required prior to addition of.fuel oil to the tank.

A period of 48 hours5.555556e-4 days <br />0.0133 hours <br />7.936508e-5 weeks <br />1.8264e-5 months <br /> is considered sufficient to complete restoration of the required level prior to declaring the DG inoperable.

This period is acceptable based on the remaining capacity

(> 6 days), the fact that procedures will be initiated to obtain replenishment, and the low probability of an event during this brief period.

D.1 This Condition is entered as a result of a failure to *meet the acceptance criterion of SR 3.8.3.3.

Normally, trending of particulate levels allows sufficient time to correct high particulate levels prior to reaching the limit of (continued)

SAN ONOFRE--UNIT 3 B 3.8-39 Amendment No.

203 04/05/07 1

Diesel Fuel Oil, Lube Oil, and Starting Air B 3.8.3 BASES (continued)

ACTIONS F.1 (continued) are accomplished on the first attempt, and the low probability of an event during this brief period.

G.1 With a Required Action and associated Completion Time not met, or one or more DGs with diesel fuel oil or lube oil not within limits for reasons other than addressed by Conditions A through F, the associated DG may be incapable of performing its intended function and must be immediately declared inoperable.

SURVEILLANCE SR 3.8.3.1 REQUIREMENTS This SR provides verification that there is an adequate inventory of fuel oil (Ž 48,400 gallons in Mode 1, 2, 3, or 4 and > 43,600 gallons in Mode 5 or 6) in the storage tanks to support each DG's operation for 7 days at full load.

The 7 day period is sufficient time to place the unit in a safe shutdown condition and to bring in replenishment fuel from an offsite location.

The 31 day Frequency is adequate to ensure that a sufficient supply of fuel oil is available, since low level alarms are provided and unit operators would be aware of any large uses of fuel oil during this period.

SR 3.8.3.2 This Surveillance ensures that sufficient lube oil inventory is available to support at least 7 days of full load operation for each DG.

The TS min (412.1 gal for the 20 cylinder engine and 369.4 gal for the 16 cylinder engine) requirements are based on the DG manufacturer consumption values for the run time of the DG.

(continued)

SAN ONOFRE--UNIT 3 B 3.8-41 Amendment No.

203 04/05/07