FENOC Submittal of 2/23/07 Letter from Nuclear Electric Insurance Limited (NEIL)
ML070950293
Person / Time
Site: Davis Besse 
(NPF-003)
Issue date: 04/04/2007
From: Pace D
FirstEnergy Nuclear Operating Co
To:
Document Control Desk, Office of Nuclear Reactor Regulation
References
3334, FOIA/PA-2007-0299
Download: ML070950293 (7)


Text

FENOC -

FirstEnergy Nuclear Operating Company 76 South Main Street Akron, Ohio 44308 DannyL. Pace Senior Vice President, Engineering 330-384-3733 Fax: 330-384-3799 Docket Number 50-346 License Number NPF-3 Serial Number 3334 April 4,2007 United States Nuclear Regulatory Commission Document Control Desk Washington, D.C. 20555-0001

Subject:

Submittal of February 23, 2007 letter fi-om Nuclear Electric Insurance Limited Ladies and Gentlemen:

As discussed during a telephone conference on April 3,2007, with members of the Nuclear Regulatory Commission staff, the FirstEnergy Nuclear Operating Company (FENOC) is enclosing a copy of the February 23,2007, letter fi-om Mr. David B. Ripsom, President and Chief Executive Officer of Nuclear Electric Insurance Limited (NEIL), to Mr. Gary R. Leidich, President and Chief Nuclear Officer of FENOC. This letter asserted a potential safety concern relating to a report prepared by the Exponent Failure Analysis Associates and Altran Solutions Corporation entitled Review and Analysis of the Davis-Besse March 2002 Reactor Pressure Vessel Head Wastage Event dated December 15,2006 (Exponent Report). The Exponent Report and opinions were developed in support of a FENOC insurance claim. This report was transmitted to the Nuclear Regulatory Commission via FENOC letter Serial Number 3331 dated March 20,2007.

Based on review of the potential safety concern, FENOC does not believe that the inspection requirements for the Davis-Besse Nuclear Power Station Reactor Pressure Vessel Head (RPVH) and the detection of cracks in the RPVH Control Rod Drive Nozzles were adversely affected by the crack growth rates utilized in the Exponent Report. These conclusions were documented in the FENOC Corrective Action Program. In addition, FENOC is performing a review of the original RPVH Root Cause Evaluations to ensure that the conclusions reflected in the Exponent Report are bounded by the Corrective Actions from these Root Cause Evaluations.

In order to facilitate the industrys analysis of this phenomenon, FENOC has submitted the Exponent Report to the Nuclear Energy Institutes (NEIs) Materials Executive Oversight Group for their assessment of ramifications on industry materials inspection guidance and generic safety implications. FENOC also provided the Exponent Report to the Institute of Nuclear Power Operations (INPO) for their information.

Docket Number 50-346 License Number NPF-3 Serial Number 3334 Page 2 of 2 If you have any questions or require further information, please contact Mr. James J. Powers, Director, Fleet Engineering, at (330) 384-4930.

Very truly yours, Danny L. Pace Senior Vice President, Fleet Engineering GMWIs Attachment Enclosure cc:

Regional Administrator, NRC Region I11 Branch Chief, NRC Region 111 Reactor Projects Branch 6 DB-1 NRC/NRR Project Manager DB-1 Senior NRC Resident Inspector Utility Radiological Safety Board

Docket Number 50-346 License Number NPF-3 Serial Number 3334 Page 1 of 1 COMMITMENT LIST The following list identifies those actions committed to by the Davis-Besse Nuclear Power Station in this document. Any other actions discussed in the submittal represent intended or planned actions by Davis-Besse. They are described only as information and are not regulatory commitments. Please notify the Manager, Regulatory Compliance (Acting), at (41 9) 321-7120 at Davis-Besse of any questions regarding this document or associated regulatory commitments.

COMMITMENTS DUE DATE None NIA

Docket Number 50-346 License Number NPF-3 Serial Number 3334 February 23,2007, letter from Mr. David B. Ripsom, President and Chief Executive Officer of Nuclear Electric Insurance Limited, to Mr. Gary R. Leidich, President and Chief Nuclear Officer of FirstEnergy Nuclear Operating Company (3 pages follow)

N E I L February 23,2007 Yia mail and First Glas Mail Mr. Gary R Leidich President and Chief Nuclear Officer FirstEneqg Nuclear Operating Company 76 South Main Street Akron,Ohio 44308 David E. Wipsom lresideni S: Chief hecutive Officer 302 858-3003 Direct 302 885-3000 Tr!

302 888-3Ni FXY 610 453-8744 Cell trripso~~~@i~mliiai.com Re:

Potential Safety Concern Arisii From Exponent Failure Analysis Gssociates and Altran Solutions Corporation, December 15,2006 Report entitled Review and Andpis of the Davis-Besse March 2002 Reactor Pressure Vessel Head Wastage Event

Dear Gary:

I am writing as a follow up to our telephone conversation earlier today. Under ordinary circumstances, I would not be contacting you regardmg matters associated with a pending claim. However, we identified a potential safely concern that has arisen out of the filings made by FirstEnergy Nuclear Operating Company (FENOC) in the arbitration dth NEIL on the Davis-Base claim. The matter has been discussed with NEIL Boslrd members (hvo with nuclear operating experience) and with former senior NRC officials. Because the concern has potential impact on Members other than FENOC, and because NEIL, as a mutual company, must take into consideration the concerns of all its Members (not to mention potential underwriting risks for NEIL itself), it was agreed that I should contact pu directly.

On December 15,2006, FENOC, tbrough its counsel, submitted to NEIL a report prepared by Exponent Failure Analysis Associates and Atran Solutions Corporation, entitled Review and Analysis of the Davis-Besse March 2002 Mctor Pressure Vessel Head Wastage Event (Exponent Report). The Eqonent Report disagrees in a number of ways with the analysis presented In the Root Cause Analysis Report entitled Significant Degradation of the Reactor Pressure Vessel Head (CR 2002-0891) that FENOC submitted to the Nuclear Regulatorg Commission (WRC). As just two examples, the Exponent Report states that the crack growth rate was significantly higher than that stated in the Root Cause Report and suggests higher metal removal rates under certain thermal hydraulic conditions than that presented In the Root Cause Report.

Indeed, in a number of places, the Exponent Report contains statements that directly call into question FENOCs conclusions in the Root Cause Report (and other submissions by FENOC to the NRC) with regard to the cause and timeline of the damage to the Davis-Besse reactor pressure vessel head. As an example, FENOC stated on page 24 of the Root Cause Report (August 27,2002) that the corrosion rate began to increase significantly starting at about 11 RFO [April 19981 and acted for a four year period of time. In contrast, the Exponent Report stated as follows:

Mr. Gary R. Leidich February 23,2007 Page 2 0

[w]e have concluded that the large wastage cavity found during the 13RFO inspection in March 2002 at Nozzle 3 could have formed in as little as a few weeks in the extreme of complete fluid cutting of the head. Exponent Report at 3-14.

0

[tlhe development of the large crack at Davis-Besse Nozzle 3 and the subsequent wastage cavity development occurred in a much shorter time frame than the root cause report concluded.

Exponent Report at 413.

NEIL has not yet had time to analyze in detail the assumptions, methodologies, models, analyses and conclusions reached in the 757 pages of the Exponent Report. However, we are concerned that the theories postulated in the Fxponent Report are indeed true, then there could be current implications for operating reactors at other NEIL ivkmbers, as well as FENOCs other PJPRS.

In particular, Exponents apparent position is that susceptible materials can have crack growth rates that are significantty higher than previously assumed and small through wall cracks can lead to high rates of erosion

~

and corrosion. Material susceptibility and crack growth rates are one of the bases for the NRCs requirements for monitoring reactor coolant system unidentified leak rates during power operation, visual (bare metal) inspections of reactor pressure vessel heads during refuekng oukges, mil periodic voluetric mamiriation of penetrations. If the theories in the Exponent Report are correct, it eould require reevaluation of the adequacy of these NRC requirements and the licensee programs implementing them to ensure that excessive degradation of a reactor pressure vessel head or other components could not occur in less than one operating cycle.

We recognize that the Exponent Report was prepared as part of an ongoing arbitration. At the same time, however, we are concerned about the possible consequences to the industry (as highlighted in the previous paragraph) that the report may cause. We therefore think it is important for NEILS Membea to know whether the opinions and conclusions set forth in the Exponent Report represent the position of FENOC with regard to the cause and timeline of the damage to the Davis-Besse reactor pressure vessel head.

One way of determining whether the Exponent Report represents FENOCs position is to look at the actions taken at Davis-Base, as well as filings that FENOC may have made, or will make, with the MC as a result of the Exponent Report. (Based on our search of the public records, we have not identified any such fillng as of today) NEIL has retained as consultants a number of former senior NRC officials and obtained their input on FENOCs reporting requirements, if any, in connection with the Exponent Report. We have been informed that, if FENOC concurs with the conclusions in the Exponent Report that the prior root cause evaluation was in error or was non-conservative, the root cause report would have to be revised and resubmitted to NRC and the LER associated wlth the event would also need to be revised In that regard, we note that the NRCs Confirmatory ktion Letter to Davis-Besse Nuclear Power Stntion (CAI, No. 3-02-001) dated March 13,2002 imposed six sets of commitments FENOC had to undertake prior to restart, including determine the root cause of the &gradation around the RW head penetrations. Because this item was closed out based on the root cause reports submitted by FENOC (see, e.g., NRC letter dated September 19,2003), we are advised that FENOC would have to inform the NRC if it now disagrees with the conclusions that formed the basis for satisfping one of the item of the CAL.

Mr. Gary R Leidkh Febmary 23,2007 Page 3 Before deciding on what actions we should take with our other Members about the safety concern discussed in this letter, we thought it prudent to contact you and q u e s t adclltional information on the actions that FENOC has taken in response to the opinions and conclusions in the Fxponent Report. We therefore request that FENOC answer the following questions:

Has FENOC prepared a Condition Report and entered the Exponent Report into the Davis-Base Corrective Action Program for analysis?

Has FENOC evaluated the opinions and conclusions in the Exponent Report with regard to what potential impact there mlght be on the various reports and analyses that were generated by FENOC to support restart of Davis-Besse?

Has FENOC emluated its reporting obhgakons to the NRC with regard to the opinions and conclusions contained in the Exponent Report, and has FENOC contemplated, or is FENOC contemplating, submitting any reports to the NRC (such as a revised root cause report) based on the opinions and conclusions in the Exponent Report?

Has FENOC evaluated the opinions and conclusions in the Exponent Report for their potential impacr on FENOC's response to the NRCs February 11,2003 Order EA-03-009 with regard to the inspection plan for the refurbished Midland reactor pressure vessel head that was installed at Davis-Besse?

~..

5) Has FENOC evaluated the opinions and conclusions in the Exponent Report for transportability to other systems and components at Davis-Besse that contain Alloy 600 (such as the pressurizer)?

8 Is FENOC planning on sharing the opinions and conclusions in the Qonent Report with the Institute for Nuclear Power Operations, the technical comrnittces or programs of the Nuclear Energy Institute and the Electric Power Research Institute, or the various reactor owners' groups?

NEIL believes that PENOC's responses to the questions posed in this letter are important so that NEIL can have a better understanding of whether the opinions and conclusions in the Exponent Report present a current safety concern for other NEIL Members and whether NEIL should share the information in the Exponent Report with the NEIL Mernbershlp for review. Understanding the response by FENOC to the Exponent Report will assist us in thii regard.

"his matter dU be a topic of substantive discussion at the upcoming NEIL Board meeting on March 9,2007.

We request that you respond before that time so that the Board can rake such information into consideration in determining further steps, if any, that may be appropriate for NEIL or its Members.

1 await your response, and if you have any questions about thii letter, please feel free to give me a call.

David B. Ripsom a