MONTHYEARInformation Notice 1990-01, Importance of Proper Response to Self-Identified Violations by Licensees1990-01-12012 January 1990 Importance of Proper Response to Self-Identified Violations by Licensees Information Notice 1987-19, Perforation and Cracking of Rod Cluster Control Assemblies1987-04-0909 April 1987 Perforation and Cracking of Rod Cluster Control Assemblies Information Notice 1987-18, Unauthorized Service on Teletherapy Units by Nonlicensed Maintenance Personnel1987-04-0808 April 1987 Unauthorized Service on Teletherapy Units by Nonlicensed Maintenance Personnel Information Notice 1987-17, Response Time of Scram Instrument Volume Level Detectors1987-04-0707 April 1987 Response Time of Scram Instrument Volume Level Detectors Information Notice 1987-16, Degradation of Static O Ring Pressure Switches1987-04-0202 April 1987 Degradation of Static O Ring Pressure Switches Information Notice 1987-15, Compliance with the Posting Requirements of Subsection 223B of the Atomic Energy Act of 1954, As Amended1987-03-25025 March 1987 Compliance with the Posting Requirements of Subsection 223B of the Atomic Energy Act of 1954, As Amended Information Notice 1987-15, Compliance with the Posting Requirements of Subsection 223b of the Atomic Energy Act of 1954, as Amended1987-03-25025 March 1987 Compliance with the Posting Requirements of Subsection 223b of the Atomic Energy Act of 1954, as Amended Information Notice 1987-14, Actuation of Fire Suppression System Causing Inoperability of Safety-Related Ventilation Equipment1987-03-23023 March 1987 Actuation of Fire Suppression System Causing Inoperability of Safety-Related Ventilation Equipment Information Notice 1987-13, Potential for High Radiation Fields Following Loss of Water from Fuel Pool1987-02-24024 February 1987 Potential for High Radiation Fields Following Loss of Water from Fuel Pool Information Notice 1987-11, Enclosure of Vital Equipment within Designated Vital Areas1987-02-13013 February 1987 Enclosure of Vital Equipment within Designated Vital Areas Information Notice 1987-11, Enclosure of Vital Equipment Within Designated Vital Areas1987-02-13013 February 1987 Enclosure of Vital Equipment Within Designated Vital Areas Information Notice 1987-12, Potential Problems with Metal Clad Circuit Breakers, General Electric Type AKF-2-251987-02-13013 February 1987 Potential Problems with Metal Clad Circuit Breakers, General Electric Type AKF-2-25 Information Notice 1987-10, Potential for Water Hammer During Restart of Residual Heat Removal Pumps1987-02-11011 February 1987 Potential for Water Hammer During Restart of Residual Heat Removal Pumps Information Notice 1987-09, Emergency Diesel Generator Room Cooling Design Deficiency1987-02-0505 February 1987 Emergency Diesel Generator Room Cooling Design Deficiency Information Notice 1987-08, Degraded Motor Leads in Limitorque DC Motor Operators1987-02-0404 February 1987 Degraded Motor Leads in Limitorque DC Motor Operators Information Notice 1987-07, Quality Control of Onsite Dewatering/Solidification Operations by Outside Contractors1987-02-0303 February 1987 Quality Control of Onsite Dewatering/Solidification Operations by Outside Contractors Information Notice 1987-05, Miswiring in a Westinghouse Rod Control System1987-02-0202 February 1987 Miswiring in a Westinghouse Rod Control System Information Notice 1987-06, Loss of Suction to Low-Pressure Service Water System Pumps Resulting from Loss of Siphon1987-01-30030 January 1987 Loss of Suction to Low-Pressure Service Water System Pumps Resulting from Loss of Siphon Information Notice 1987-04, Diesel Generator Fails Test Because of Degraded Fuel1987-01-16016 January 1987 Diesel Generator Fails Test Because of Degraded Fuel Information Notice 1987-03, Segregation of Hazardous and Low-Level Radioactive Wastes1987-01-15015 January 1987 Segregation of Hazardous and Low-Level Radioactive Wastes Information Notice 1987-02, Inadequate Seismic Qualification of Diaphragm Valves by Mathematical Modeling and Analysis1987-01-13013 January 1987 Inadequate Seismic Qualification of Diaphragm Valves by Mathematical Modeling and Analysis Information Notice 1986-11, Anomalous Behavior of Recirculation Loop Flow in Jet Pump BWR Plants1986-12-31031 December 1986 Anomalous Behavior of Recirculation Loop Flow in Jet Pump BWR Plants ML0530703841986-12-29029 December 1986 Degradation of Reactor Coolant System Pressure Boundary Resulting from Boric Acid Corrosion Information Notice 1986-99, Degradation of Steel Containment1986-12-0808 December 1986 Degradation of Steel Containment Information Notice 1986-98, Offsite Medical Services1986-12-0202 December 1986 Offsite Medical Services Information Notice 1986-97, Emergency Communications System1986-11-28028 November 1986 Emergency Communications System Information Notice 1986-96, Heat Exchanger Fouling Can Cause Inadequate Operability of Service Water Systems1986-11-20020 November 1986 Heat Exchanger Fouling Can Cause Inadequate Operability of Service Water Systems Information Notice 1986-95, Leak Testing Iodine-125 Sealed Sources in Lixi, Inc. Imaging Devices and Bone Mineral Analyzers1986-11-10010 November 1986 Leak Testing Iodine-125 Sealed Sources in Lixi, Inc. Imaging Devices and Bone Mineral Analyzers Information Notice 1986-94, Hilti Concrete Expansion Anchor Bolts1986-11-0606 November 1986 Hilti Concrete Expansion Anchor Bolts Information Notice 1986-92, Pressurizer Safety Valve Reliability1986-11-0404 November 1986 Pressurizer Safety Valve Reliability Information Notice 1986-90, Requests to Dispose of Very Low-Level Radioactive Waste Pursuant to 10 CFR 20.3021986-11-0303 November 1986 Requests to Dispose of Very Low-Level Radioactive Waste Pursuant to 10 CFR 20.302 Information Notice 1986-91, Limiting Access Authorizations1986-11-0303 November 1986 Limiting Access Authorizations Information Notice 1986-93, IEB 85-03 Evaluation of Motor-Operators Identifies Improper Torque Switch Settings1986-11-0303 November 1986 IEB 85-03 Evaluation of Motor-Operators Identifies Improper Torque Switch Settings Information Notice 1986-93, Ieb 85-03 Evaluation of Motor-Operators Identifies Improper Torque Switch Settings1986-11-0303 November 1986 Ieb 85-03 Evaluation of Motor-Operators Identifies Improper Torque Switch Settings Information Notice 1986-89, Uncontrolled Rod Withdrawal Because of a Single Failure1986-10-16016 October 1986 Uncontrolled Rod Withdrawal Because of a Single Failure Information Notice 1986-88, Compensatory Measures for Prolonged Periods of Security Systems Failures1986-10-15015 October 1986 Compensatory Measures for Prolonged Periods of Security Systems Failures Information Notice 1986-86, Clarification of Requirements for Fabrication and Export of Certain Previously Approved Type B Packages1986-10-10010 October 1986 Clarification of Requirements for Fabrication and Export of Certain Previously Approved Type B Packages Information Notice 1986-87, Loss of Offsite Power Upon an Automatic Bus Transfer1986-10-10010 October 1986 Loss of Offsite Power Upon an Automatic Bus Transfer Information Notice 1986-85, Enforcement Actions Against Medical Licensees for Willful Failure to Report Misadministrations1986-10-0303 October 1986 Enforcement Actions Against Medical Licensees for Willful Failure to Report Misadministrations Information Notice 1986-84, Rupture of a Nominal 40-Millicurie Iodine-125 Brachytherapy Seed Causing Significant Spread of Radioactive Contamination1986-09-30030 September 1986 Rupture of a Nominal 40-Millicurie Iodine-125 Brachytherapy Seed Causing Significant Spread of Radioactive Contamination Information Notice 1986-83, Underground Pathways Into Protected Areas, Vital Areas, Material Access Areas, & Controlled Access Areas1986-09-19019 September 1986 Underground Pathways Into Protected Areas, Vital Areas, Material Access Areas, & Controlled Access Areas Information Notice 1986-83, Underground Pathways into Protected Areas, Vital Areas, Material Access Areas, & Controlled Access Areas1986-09-19019 September 1986 Underground Pathways into Protected Areas, Vital Areas, Material Access Areas, & Controlled Access Areas Information Notice 1986-82, Failures of Scram Discharge Volume Vent and Drain Valves1986-09-16016 September 1986 Failures of Scram Discharge Volume Vent and Drain Valves Information Notice 1986-81, Broken Inner-External Closure Springs on Atwood & Morrill Main Steam Isolation Valves1986-09-15015 September 1986 Broken Inner-External Closure Springs on Atwood & Morrill Main Steam Isolation Valves Information Notice 1986-80, Unit Startup with Degraded High Pressure Safety Injection System1986-09-12012 September 1986 Unit Startup with Degraded High Pressure Safety Injection System Information Notice 1986-78, Scram Solenoid Pilot Valve (SSPV) Rebuild Kit Problems1986-09-0202 September 1986 Scram Solenoid Pilot Valve (SSPV) Rebuild Kit Problems Information Notice 1986-79, Degradation or Loss of Charging Systems at PWR Nuclear Power Plants using Swing-Pump Designs1986-09-0202 September 1986 Degradation or Loss of Charging Systems at PWR Nuclear Power Plants using Swing-Pump Designs Information Notice 1986-79, Degradation or Loss of Charging Systems at PWR Nuclear Power Plants Using Swing-Pump Designs1986-09-0202 September 1986 Degradation or Loss of Charging Systems at PWR Nuclear Power Plants Using Swing-Pump Designs Information Notice 1986-77, Computer Program Error Report Handling1986-08-28028 August 1986 Computer Program Error Report Handling Information Notice 1986-76, Problems Noted in Control Room Emergency Ventilation Systems1986-08-28028 August 1986 Problems Noted in Control Room Emergency Ventilation Systems 1990-01-12
[Table view]Some use of "" in your query was not closed by a matching "". |
I-
SSINS No.: 6835 Accession No.:
'8103300415 IN 81-27 UNITED STATES
NUCLEAR REGULATORY COMMISSION
OFFICE OF INSPECTION AND ENFORCEMENT
WASHINGTON, D.C. 20555 September 3, 1981 IE INFORMATION NOTICE NO. 81-27: FLAMMABLE GAS MIXTURES IN THE WASTE GAS
DECAY TANKS IN PWR PLANTS
Description of Circumstances
In July 1981, hydrogen ignition occurred in one gaseous waste decay tank at
San Onofre Unit 1 while the plant was in cold shutdown. This resulted in a
release of about 8.8 curies of noble gases and minor tank damage. The cause
of the hydrogen ignition was air contamination of the inert nitrogen system
which is used to control the hydrogen-oxygen, concentrations in the tank.
The source of air was identified as instrument air leaking through check valves
at the cross connections between instrument air and nitrogen lines. Under normal
operating conditions, the pressure in the instrument air system is higher than
that of the nitrogen system. These cross connections had been installed in
response to TMI Action Plan requirement item II.E.1.2 of NUREG-0737. The nitrogen
system provided a backup gas supply to the air-operated steam supply valve for
the steam-driven auxiliary feedwater pump. This backup was installed to provide
a "safety grade" auxiliary feedwater system that satisfies the single-failure
criteria. Other cross connections, which apparently did not leak air into the
nitrogen system, had been previously installed in response to TMI Action Plan
requirement II.G.1 of NUREG-0737 to provide a redundant gas supply to the
air-operated pressurizer relief valves and the associated block valves.
Following the occurrence, the licensee sampled all potentially affected tanks
and determined that most of the tanks had oxygen levels above 10 to 15 percent.
Generally, the gas in pressurized water reactor (PWR) waste ga' ;ystems is
hydrogen rich and the oxygen concentration is controlled to prevent flammable
gas mixtures. Flammable concentration of gas mixtures can be prevented by
limiting either the hydrogen or the oxygen concentration to less than 3 percent.
To eliminate the possibility of recurrence, the licensee has now completely
separated those portions of the nitrogen system that are a backup supply to
the air system from the balance of the nitrogen system that supplies, cover gas.
Bottles of compressed nitrogen are now used to provide the backup to the air
system.
We are aware of another instance of flammable mixtures in waste gas tanks.
In August 1980, Arkansas Power and Liqht Company (AP&L) di,.covered flammable
concentrations of hydro(len and oxyqen in the w,1st, (las de(yv tanks at Arkar,;as
Nuclear One, Unit I. The flammatble qas mitx ture wert, crealted after the primary
coolant picked up oxv(jen from the air durinq rf,? u, Iinq anl maint,-n1vn 1(e. No
iqnition or ePplosion.wa'. r-pporle(l
IN 81-27 September 3, 1981 It appears that licensees need to devote more attention to the potential effects
of nitrogen-air system cross connections when systems are modified to use nitrogen
as a backup to air systems. If cross connections exist, the potential for the
formation of flammable gas mixtures should be evaluated. A sampling program to
assure that flammable gas mixtures do not exist in tanks should be considered.
No written response to this information notice is required. If you need
additional information with regard to this subject, please contact the Director
of the appropriate NRC Regional Office.