Yankee Nuclear, Final Status Survey Report, Appendix D - YA-REPT-00-003-05 Generic ALARA Evaluation Comparison Worksheet
ML070030551
Person / Time
Site: Yankee Rowe
Issue date: 06/21/2005
From: Hummer J, Danni Smith
Yankee Atomic Electric Co
To:
NRC/FSME
References
YA-REPT-00-003-05, YNPS FSS-OOL05-00
Download: ML070030551 (9)


Text

Generic ALARA Evaluation Comparison Worksheet I S w e y Area: DOL-OCT Survey Unit: r) I Reference Generic ALARA Evaluation No.: Y A - RE f T 6 0 3 '0 57 Applicable Generic ALARA AL: (65 Radionuclide Avera~eConcentration DCGL* fraction DCGL Z(f?acrion DCGL) = 0 .f 3

~ D C C I Lu d : u gewr;c / + ~ f i R f E:vd\, l

' If the Z(fraction DCGL) < the generic ALARA AL, then the generic ALARA evaluation

/ is applicable to the survey unit.

Check one:

Generic ALARA AL satisfied.

Generic ALARA AL IS NOT satisfied.

Date: f ?/OF

- Date: 6&//4~-

FSS Project ~ a n k ~ e r i ~ a d i a tProtection ion Manager DPF-8867.1 Rev. 2 Page 1 of 1

Generic ALARA Evaluation Comparison Worksheet Survey Area: OOL-05 Survey Unit: 03 Reference Generic ALARA Evaluation No.: YA-REPT-00-003-05 Applicable Generic A U R A AL: 165 Radionuclide Average Concentration DCGL fraction DCGL 1 CS-137 0.0285 3 9.50E-03 2

3 4

Ctfraction DCGL): 9.50E-03 If the Ctfraction DCGL) < the generic ALARA AL, then the generic ALARA evaluation is applicable to the survey unit.

Check one:

X Generic ALARA AL IS satisfied.

Generic ALARA AL IS NOT satisfied.

Prepared by: G. P. Astrauckas Date: 8/28/2006 FSS Radiological Reviewed by: Date:

FSS Projkct Manage Protection Manager

Generic ALARA Evaluation Comparison Worksheet Survey Area: OOL-05 Survey Unit: 04 Reference Generic ALARA Evaluation No.: YA-REPT-00-003-05 Applicable Generic ALARA AL: 165 Radionuclide Average Concentration DCGL fraction DCGL 1 CS-137 0.1068 3 3.56E-02 2 Co-60 0.0217 1.4 1.55E-02 3

4 C(fraction DCGL): 5.1 1E-02 If the C(fraction DCGL) < the generic ALARA AL, then the generic ALARA evaluation is applicable to the survey unit.

Check one:

X Generic ALARA AL IS satisfied.

Generic ALARA AL IS NOT satisfied.

Prepared by: Date: 811412006 Reviewed by: ,-#= p_ - Date:

FSS P r h c t ~ a n d e r l ~ a d i a t i oProtection n Manager

Generic ALARA Evaluation Comparison Worksheet Survey Area: 00L-05 Survey Unit: 05 Reference Generic ALARA Evaluation No.: YA-REPT-00-003-05 Applicable Generic ALARA AL: 165 Radionuclide Average Concentration DCGL fraction DCGL 1 CS-I37 0.0292 3 9.73E-03 2

3 4

C(fraction DCGL): 9.73E-03 If the C(fraction DCGL) < the generic ALARA AL, then the generic ALARA evaluation is applicable to the survey unit.

Check one:

X Generic ALARA AL IS satisfied.

Generic ALARA AL IS NOT satisfied.

Prepared by: J. W. Bisson Date: 7/5/2006 Reviewed by: -Y)q Date: s,k,,/~ 1 FSS Pkject Manag L A

Generic ALARA Evaluation Comparison Worksheet Survey Area: 00L-05 Survey Unit: 06 Reference Generic ALARA Evaluation No.: YA-REPT-00-003-05 Applicable Generic ALARA AL: 1 65 Radionuclide Average Concentration DCGL fraction DCGL

1. 0-137 0.03 pCiln 3.0 vCi/g 0.01 2.

Z(fraction DCGL) = 0.01 If the C(fraction DCGL) < the generic ALARA AL, then the generic ALARA evaluation is applicable to the survey unit.

Check one:

Generic ALARA AL IS satisfied.

Generic ALARA AL IS NOT satisfied.

r e p by:

Reviewed by: .* L- h-L FSS kroject ~ h a ~ e r Date: 7k,rAc DPF-8867.1 Page 1 of 1

Generic ALARA Evaluation Comparison Worksheet Survey Area: 00L-05 Survey Unit: 07 Reference Generic ALARA Evaluation No.: YA-REPT-00-003-05 Applicable Generic ALARA AL: 165 Radionuclide Average Concentration DCGL fraction DCGL 4.

C(fiaction DCGL) = 0.126 If the C(fraction DCGL) < the generic ALARA AL, then the generic ALARA evaluation is applicable to the survey unit.

Check one:

Generic ALARA AL IS satisfied.

Generic ALARA AL IS NOT satisfied.

Prepared by: Date:

DPF-8867.1 Page 1 of 1

Generic ALARA Evaluation Comparison Worksheet Survey Area: OOL-05 Survey Unit: 08 Reference Generic ALARA Evaluation No.: YA-REPT-00-003-05 Applicable Generic ALARA AL: 165 Radionuclide Average Concentration DCGL fraction DCGL 1 CS-137 0.0292 3 9.73E-03 2

3 4

C(fraction DCGL): 9.73E-03 If the C(fraction DCGL) < the generic ALARA AL, then the generic ALARA evaluation is applicable to the sutvey unit.

Check one:

X Generic ALARA AL satisfied.

Generic ALARA AL IS NOT satisfied.

zs- &

Prepared by: J W. Bisson Date: 7/@d2006 FSS Radiolo@l Engineer Reviewed by: tnr\ r 3 Date:

FSS PrS$Managd%ktion Protection Manager

Generic ALARA Evaluation Comparison Worksheet Survey Area: OOL-05 Survey Unit: 09 Reference Generic ALARA Evaluation No.: YA-REPT-00-003-05 Applicable Generic ALARA AL: 165 Radionuclide Average Concentration DCGL fraction DCGL 1 CS-137 0.0291 3 9.70E-03 2

3 4

C(fraction DCGL): 9.70E-03 If the C(fraction DCGL) < the generic ALARA AL, then the generic ALARA evaluation is applicable to the survey unit.

Check one:

X Generic ALARA AL satisfied.

Generic ALARA AL IS NOT satisfied.

Prepared by: Nancy Touie Date: 8/2/2006 FSS ~adiolo&al Engine Reviewed by: P- %,. r a_, ate:

&&c Man&er/Radiation Protection Manager

~~~~-~ ~ - -

Generic ALARA Evaluation Comparison Worksheet r

Survey Area: OOL-05 Survey Unit: 10 Reference Generic ALARA Evaluation No.: YA-REPT-00-003-05 Applicable Generic ALARA AL: 165 Radionuclide Average Concentration DCGL fraction DCGL I CS-137 0.0291 3 9.70E-03 2

3 4

C(fraction DCGL): 9.70E-03 If the C(fraction DCGL) < the generic ALARA AL, then the generic ALARA evaluation is applicable to the survey unit.

Check one:

X Generic ALARA AL satisfied.

Generic ALARA AL IS NOT satisfied.

Prepared by: Nancy Tozzie Date: 8/2/2006 FSS Radiologi6l En Reviewed by:

C--

FSS Projebt ~ h a g e r l R a d i d o nProtection Manager Date: