ML063340263
| ML063340263 | |
| Person / Time | |
|---|---|
| Site: | Yankee Rowe |
| Issue date: | 08/05/2005 |
| From: | Danni Smith Yankee Atomic Electric Co |
| To: | NRC/FSME |
| References | |
| NOL-02, YA-REPT-00-003-05 | |
| Download: ML063340263 (4) | |
Text
Generic ALARA Evaluation Comparison Worksheet Survey Area:
NOL-02 Survey Unit:
0 1 Reference Generic ALARA Evaluation No.:
YA-REPT-00-003-05 Applicable Generic ALARA AL:
165 Radionuclide Average Concentration DCGL fraction DCGL
- 1.
Co-60 0.05 1.4 0.04
- 2.
CS-137 0.22 3
0.07
- 3.
- 4.
Z(fraction DCGL) =
0.1 1 If the E(fraction DCGL) < the generic ALARA AL, then the generic ALARA evaluation is applicable to the survey unit.
Check one:
J Generic ALARA AL IS satisfied.
Generic ALARA AL IS NOT satisfied.
Date: <A;A.c Date:
g o-~'
FSS Project Manager DPF-8867.1 Rev. 2 Page 1 of 1
Generic ALARA Evaluation Comparison Worksheet Survey Area:
NOL-02 Survey Unit:
02 Reference Generic ALARA Evaluation No. :
YA-REPT-00-003-05 Applicable Generic ALARA AL:
165 Radionuclide Average Concentration DCGL fraction DCGL
- 1.
Co-60 0.05 1.4 -- --
0.04
- 2.
CS-137 0.22 3
0.07 2
Z(fkaction DCGL) =
0.1 1 If the Z(fiaction DCGL) < the generic ALARA AL, then the generic ALAMi evaluation is applicable to the survey unit.
Check one:
X Generic ALARA AL IS satisfied.
Generic ALARA AL IS NOT satisfied.
Prepared by:
Date:
DPF-8867.1 Rev. 2 Page 1 of 1
Generic ALARA Evaluation Comparison Worksheet Survey Area:
NOL-02 Survey Unit:
03 Reference Generic ALARA Evaluation No.:
YA-REPT-00-003-05 Applicable Generic ALARA AL:
165 Radionuclide Average Concentration DCGL fraction DCGL If the E(fraction DCGL) < the generic ALARA AL, then the generic ALARA evaluation is applicable to the survey unit.
Check one:
C(fraction DCGL) =
X Generic ALARA AL IS satisfied.
Generic ALARA AL IS NOT satisfied.
0.069 Prepared by:& &&
Date: '5 1 \\ 710 6 F
Radiological i er Date: sA,,h~
DPF-8867.1 Rev. 2 Page 1 of 2
Generic ALARA Evaluation Comparison Worksheet Survey Area:
NOL-02 Survey Unit:
04 Reference Generic ALARA Evaluation No.:
YA-REPT-00-003-05 Applicable Generic ALARA AL:
165 Radionuclide Average Concentration DCGL fraction DCGL 1
Co-60 0.1055 1.4 7.54E-02 2
CS-137 0.0407 3
1.36E-02 3
4 C(fraction DCGL):
8.89E-02 If the C(fraction DCGL) c the generic ALARA AL, then the generic ALARA evaluation is applicable to the survey unit.
Check one:
X Generic ALARA AL IS satisfied.
Generic ALARA AL IS NOT satisfied.
Prepared by: Robert Tozzie Date:
7/24/2006 FSS Radiological ~nginee"r Reviewed by: - '
[ ', k
.,'A Date: 7/ib&,,
FSS ~rdject
~anag4rl~adiation Protection Manager