Category:Press Release
MONTHYEARML23166A0212023-03-10010 March 2023 News Release-I-23-002: NRC to Meet with Connecticut Nuclear Energy Advisory Council to Discuss Millstone Nuclear Power Plant 2022 Performance ML22346A0552022-11-23023 November 2022 News Release-I-22-016: NRC Schedules Decommissioning Webinar for Nuclear Power Plant Emergency Preparedness and Security Requirements ML22346A0562022-11-21021 November 2022 News Release-I-22-015: NRC Names New Resident Inspector at Salem Nuclear Power Plant ML22346A0572022-11-10010 November 2022 News Release-I-22-014: West Virginia Hospital to Take Corrective Actions Under Settlement Agreement with NRC ML22305A5512022-10-14014 October 2022 News Release-I-22-013: NRC Imposes Civil Penalty to Pennsylvania Company ML22270A0832022-09-14014 September 2022 News Release-I-22-012: NRC Names New Resident Inspector at Peach Bottom Nuclear Power Plant ML22255A0872022-09-0909 September 2022 News Release-I-22-011: NRC to Conduct Pre-Decisional Enforcement Conference with a Connecticut Medical Facility ML22217A0572022-08-0505 August 2022 News Release-I-22-010: New NRC Senior Resident Inspector Assigned to Calvert Cliffs Nuclear Power Plant ML22215A2132022-07-28028 July 2022 News Release-I-22-009: NRC Names New Resident Inspector at Ginna Nuclear Power Plant Press Release-I-22-008, NRC Names New Resident Inspector at Limerick Nuclear Power Plant2022-06-22022 June 2022 Press Release-I-22-008: NRC Names New Resident Inspector at Limerick Nuclear Power Plant ML22153A1262022-05-26026 May 2022 News Release-I-22-007: NRC Schedules Webinar to Discuss 2021 Safety Performance at Maryland, New Jersey, New York, Pennsylvania Nuclear Power Plants ML22131A1432022-05-0606 May 2022 News Release-I-22-006: NRC to Hold Public Meeting to Discuss Seabrook Station 2021 Safety Performance ML22131A1422022-05-0202 May 2022 News Release-I-22-005: NRC Proposes $3,500 Defense Health Agency Fine for Loss of Medical Purpose Radioactive Material ML22083A0522022-03-18018 March 2022 News Release-I-22-004: NRC to Meet with Connecticut Nuclear Energy Advisory Council to Discuss Millstone Nuclear Power Plant 2021 Performance ML22063A4642022-03-0202 March 2022 News Release-I-22-003: NRC Proposes $25,600 Fine for Pennsylvania Company ML22028A0502022-01-26026 January 2022 News Release-I-22-002: NRC Issues Confirmatory Order, $50,000 Civil Penalty to HDI Over Security-Related Violations at Oyster Creek Nuclear Power Plant Press Release-I-22-001, NRC Names New Senior Resident Inspector at Salem Nuclear Power Plant2022-01-10010 January 2022 Press Release-I-22-001: NRC Names New Senior Resident Inspector at Salem Nuclear Power Plant Press Release-I-21-010, NRC Proposes $150,000 Civil Penalty for Violations at New Jersey Nuclear Power Plant Undergoing Decommissioning2021-12-22022 December 2021 Press Release-I-21-010: NRC Proposes $150,000 Civil Penalty for Violations at New Jersey Nuclear Power Plant Undergoing Decommissioning Press Release-I-21-009, NRC Issues Confirmatory Action Letter to West Virginia Hospital2021-11-19019 November 2021 Press Release-I-21-009: NRC Issues Confirmatory Action Letter to West Virginia Hospital Press Release-I-21-007, NRC to Hold Public Meeting to Receive Comments on Indian Point Nuclear Power Plant Decommissioning Activities Report2021-07-19019 July 2021 Press Release-I-21-007: NRC to Hold Public Meeting to Receive Comments on Indian Point Nuclear Power Plant Decommissioning Activities Report Press Release-I-21-006, NRC Proposes $3,750 Fine for Connecticut Hospital Violations2021-06-0202 June 2021 Press Release-I-21-006: NRC Proposes $3,750 Fine for Connecticut Hospital Violations Press Release-I-21-005, NRC Schedules Webinar to Discuss 2020 Safety Performance at Maryland, New Jersey, New York and Pennsylvania Nuclear Power Plants2021-06-0101 June 2021 Press Release-I-21-005: NRC Schedules Webinar to Discuss 2020 Safety Performance at Maryland, New Jersey, New York and Pennsylvania Nuclear Power Plants Press Release-I-21-004, NRC to Hold Virtual Meeting to Discuss 2020 Performance of Seabrook Nuclear Power Plant2021-05-24024 May 2021 Press Release-I-21-004: NRC to Hold Virtual Meeting to Discuss 2020 Performance of Seabrook Nuclear Power Plant Press Release-I-21-003, NRC to Meet with Connecticut Nuclear Energy Advisory Council to Discuss Millstone Nuclear Power Plant Performance2021-03-11011 March 2021 Press Release-I-21-003: NRC to Meet with Connecticut Nuclear Energy Advisory Council to Discuss Millstone Nuclear Power Plant Performance Press Release-I-21-002, NRC Names New Senior Resident Inspector at Indian Point Unit 3 Nuclear Power Plant2021-02-17017 February 2021 Press Release-I-21-002: NRC Names New Senior Resident Inspector at Indian Point Unit 3 Nuclear Power Plant Press Release-I-21-001, NRC Proposes $8,500 Civil Penalty to Puerto Rico Firm for Apparent Violation Involving Nuclear Gauges2021-01-14014 January 2021 Press Release-I-21-001: NRC Proposes $8,500 Civil Penalty to Puerto Rico Firm for Apparent Violation Involving Nuclear Gauges Press Release-I-21-011, NRC Names New Resident Inspector for Nine Mile Point Nuclear Plant2020-12-28028 December 2020 Press Release-I-21-011: NRC Names New Resident Inspector for Nine Mile Point Nuclear Plant Press Release-I-20-023, NRC Names New Resident Inspector at Millstone Station2020-12-0707 December 2020 Press Release-I-20-023: NRC Names New Resident Inspector at Millstone Station Press Release-I-20-022, NRC Resident Inspector Newly Assigned to Calvert Cliffs Nuclear Power Plant2020-11-12012 November 2020 Press Release-I-20-022: NRC Resident Inspector Newly Assigned to Calvert Cliffs Nuclear Power Plant Press Release-I-20-021, NRC Names New Senior Resident Inspector at Seabrook Station2020-10-20020 October 2020 Press Release-I-20-021: NRC Names New Senior Resident Inspector at Seabrook Station Press Release-I-20-020, NRC Names New Resident Inspector at Beaver Valley Nuclear Power Plant2020-10-14014 October 2020 Press Release-I-20-020: NRC Names New Resident Inspector at Beaver Valley Nuclear Power Plant Press Release-I-20-019, NRC Names New Senior Resident Inspector at Susquehanna Nuclear Power Plant2020-09-28028 September 2020 Press Release-I-20-019: NRC Names New Senior Resident Inspector at Susquehanna Nuclear Power Plant Press Release-I-20-018, NRC to Hold Virtual Meeting to Discuss 2019 Performance of Indian Point Nuclear Power Plant2020-09-0101 September 2020 Press Release-I-20-018: NRC to Hold Virtual Meeting to Discuss 2019 Performance of Indian Point Nuclear Power Plant Press Release-I-20-017, NRC Names New Senior Resident Inspector at Beaver Valley Nuclear Power Plant2020-08-18018 August 2020 Press Release-I-20-017: NRC Names New Senior Resident Inspector at Beaver Valley Nuclear Power Plant Press Release-I-20-016, New NRC Senior Resident Inspector Assigned to Hope Creek Nuclear Power Plant2020-07-0909 July 2020 Press Release-I-20-016: New NRC Senior Resident Inspector Assigned to Hope Creek Nuclear Power Plant Press Release-I-20-015, NRC Senior Resident Inspector Newly Assigned to Limerick Nuclear Power Plant2020-07-0606 July 2020 Press Release-I-20-015: NRC Senior Resident Inspector Newly Assigned to Limerick Nuclear Power Plant Press Release-I-20-014, NRC Proposes $7,500 Fine to Puerto Rico Firm for Apparent Violation Involving Nuclear Gauges2020-06-25025 June 2020 Press Release-I-20-014: NRC Proposes $7,500 Fine to Puerto Rico Firm for Apparent Violation Involving Nuclear Gauges Press Release-I-20-013, NRC Names Resident Inspector at FitzPatrick Nuclear Power Plant2020-06-24024 June 2020 Press Release-I-20-013: NRC Names Resident Inspector at FitzPatrick Nuclear Power Plant Press Release-I-20-012, NRC to Hold Virtual Meeting to Discuss 2019 Performance of FitzPatrick, Nine Mile Point and Ginna Nuclear Power Plants2020-06-15015 June 2020 Press Release-I-20-012: NRC to Hold Virtual Meeting to Discuss 2019 Performance of FitzPatrick, Nine Mile Point and Ginna Nuclear Power Plants Press Release-I-20-011, NRC Names New Senior Resident Inspector at Indian Point Nuclear Power Plant2020-06-0505 June 2020 Press Release-I-20-011: NRC Names New Senior Resident Inspector at Indian Point Nuclear Power Plant Press Release-I-20-010, NRC Names New Resident Inspector at Hope Creek Nuclear Power Plant2020-06-0404 June 2020 Press Release-I-20-010: NRC Names New Resident Inspector at Hope Creek Nuclear Power Plant ML20149K5522020-05-28028 May 2020 Press Release I-20-009: NRC Names New Senior Resident Inspector at Peach Bottom Nuclear Power Plant Press Release-I-20-008, NRC Schedules Webinar to Discuss 2019 Safety Performance at Pennsylvania and Maryland Nuclear Power Plants2020-05-27027 May 2020 Press Release-I-20-008: NRC Schedules Webinar to Discuss 2019 Safety Performance at Pennsylvania and Maryland Nuclear Power Plants Press Release-I-20-007, NRC to Hold Virtual Meeting to Discuss 2019 Performance of Salem and Hope Creek Nuclear Power Plants2020-05-21021 May 2020 Press Release-I-20-007: NRC to Hold Virtual Meeting to Discuss 2019 Performance of Salem and Hope Creek Nuclear Power Plants Press Release-I-20-006, NRC to Hold Virtual Meeting to Discuss 2019 Performance of Seabrook Nuclear Power Plant2020-05-20020 May 2020 Press Release-I-20-006: NRC to Hold Virtual Meeting to Discuss 2019 Performance of Seabrook Nuclear Power Plant Press Release-I-20-005, NRC Proposes $7,500 Fine for West Virginia Engineering Firm2020-04-27027 April 2020 Press Release-I-20-005: NRC Proposes $7,500 Fine for West Virginia Engineering Firm Press Release-I-20-004, NRC Proposes $7,500 Civil Penalty for Company Violations at Puerto Rico Facility2020-04-24024 April 2020 Press Release-I-20-004: NRC Proposes $7,500 Civil Penalty for Company Violations at Puerto Rico Facility Press Release-I-20-003, NRC to Meet with Connecticut Nuclear Energy Advisory Council to Discuss Millstone Nuclear Power Plant Performance2020-04-0808 April 2020 Press Release-I-20-003: NRC to Meet with Connecticut Nuclear Energy Advisory Council to Discuss Millstone Nuclear Power Plant Performance Press Release-I-20-002, NRC to Conduct Public Webinar on April 21 to Discuss Indian Point Nuclear Power Plant Decommissioning Topics2020-04-0707 April 2020 Press Release-I-20-002: NRC to Conduct Public Webinar on April 21 to Discuss Indian Point Nuclear Power Plant Decommissioning Topics Press Release-I-20-001, NRC Names New Resident Inspector at R.E. Ginna Nuclear Power Plant2020-01-0909 January 2020 Press Release-I-20-001: NRC Names New Resident Inspector at R.E. Ginna Nuclear Power Plant 2023-03-10
[Table view]Some use of "" in your query was not closed by a matching "". |
Text
NRC NEWS U.S. NUCLEAR REGULATORY COMMISSION Office of Public Affairs, Region I 475 Allendale Road, King of Prussia, Pa.
www.nrc.gov No. I-06-060 November 21, 2006
Contact:
Diane Screnci, 610/337-5330 E-mail: opa1@nrc.gov Neil Sheehan, 610/337-5331 NRC, PA. COMPANY TO DISCUSS APPARENT VIOLATIONS STEMMING FROM TEMPORARY LOSS OF NUCLEAR GAUGE Nuclear Regulatory Commission staff will meet with representatives of a Bethlehem, Pa.,
engineering firm on Tuesday, Nov. 28, to discuss three apparent violations of agency requirements involving the control and security of NRC-licensed radioactive materials. The apparent violations stem from the temporary loss of a nuclear gauge in August and were identified during an NRC special inspection conducted in September at the offices of Pennoni Associates, Inc., and at two temporary job sites.
The predecisional enforcement conference is scheduled to begin at 10 a.m. at the NRC Region I Office, at 475 Allendale Road in King of Prussia, Pa. It will be open to the public for observation, though portions may be closed, if necessary, to discuss specific security aspects of the apparent violations.
On Aug. 21, Pennoni notified the NRC that a portable nuclear gauge belonging to the firm was missing. The gauge, which contains small amounts of radioactive material and is used for such purposes as measuring soil density at construction sites, had been stored in a vehicle owned by a company employee authorized to use it. The employee had loaned the vehicle to a relative at 11 p.m.
on Aug. 19 to perform a short errand. The gauge was stored in the back seat of the vehicle when it was borrowed. It was inside a locked transportation container, which was secured to the vehicle by a locked cable. The vehicle was not returned to the company employee, as promised.
On Aug. 23, another relative of the company employee located the vehicle and returned it.
However, the gauge and its transportation container were missing. The relative informed the Pennoni staffer that the gauge had been removed from the vehicle and left on the front porch of a residence in Bethlehem. The company retrieved the gauge from the porch on the morning of Aug. 24 and returned it to a company storage location in Bethlehem. It was determined that a lock on the transportation container had been broken and one of its handles damaged. However, there was no damage to the gauge and the radioactive material inside was still safely shielded.
An NRC special inspection was conducted on Sept. 7 and 8 to review the circumstances surrounding the event. The inspection took place at the companys offices in Bethlehem and at temporary job sites in Rehrersburg and Chambersburg, Pa.
The apparent violations by Pennoni are as follows: 1) a failure to use a minimum of two independent physical controls to prevent unauthorized removal of a nuclear gauge when it was not under direct control and constant surveillance of company personnel; 2) a failure to maintain constant surveillance of the device in an unrestricted area; and 3) a failure to make an immediate telephone report to the NRC after the gauge was discovered to be missing.
The purpose of the Nov. 28th meeting is to obtain information to enable the NRC to determine what, if any, enforcement action is warranted. There will be an effort to come to a common understanding of the facts and a discussion of root causes of the event and corrective actions undertaken by the company.
No decision will be made by the NRC staff at the session. Rather, NRC management will render a decision sometime in the near future.