Entergy Center Status Report
ML062830172
Person / Time
Site: Indian Point  
Issue date: 06/06/2006
From:
Entergy Operations
To:
Office of Nuclear Reactor Regulation
References
FOIA/PA-2006-0244
Download: ML062830172 (2)


Text

As Indian Point Energy Center Status Report June 6, 2006 Operational Status IP2 is currently at 100% reactor power; the unit has been on line for 19 days and Unit 3 is operating at 100% reactor power and has been on-line for 247 days.

Groundwater Investigation - MW-42 Well Entergy released updated/corrected sample results today from a series of samples obtained from MW-

"MW-42 9 42, which is located adjacent to the Unit I spent fuel pool. The results show isotopes characteristic of North curtain drain water. (See diagram showing updated sample results). Hydrologists are investigating the possibility that the well intercepted a section of the North curtain drains at Unit 1. The updated sample results do not affect the bounding dose calculations. Results for tritium are lower than previously reported although the Cesium numbers are higher. An additional sample taken on April 7 showed results consistent with the 1020001 corrected data from March 23/24.

1 MW-42 @ 49' Sampled 19 49' April 7, 2006 L.IL..J d

Results in pCi/L r

H-3 3980 Sr-90 74.6 Cs-137 5310 Co-60 67.2 Entergy has initiated actions to reduce the I:

concentration of Sr-90 in the Unit 1 spent fuel1" pool. Deminieralizers connected to the pool will J,

help reduce the amount of Sr-90 in the pool and thus the amount which is captured by the curtain drains. Entergy is evaluating additional processing Samples taken 3/23-24/2006 in the curtain drains to further reduce the Sr-90 Corrected results are in green.

concentration. These actions are being taken in advance Previously reported tritium value of any overall site remediation plan and will enhance the was 261,000pCi/L and the Cs-137 effectiveness of which ever strategy maybe employed, number was 10,200pCi/L. All results in pCi/L

/

(if)

~Enler~gy Tracer tests, mentioned above, will help evaluate the effectiveness of the Sr-90 processing.

No radioactivity has been detected in any off-site monitoring location.

Educational Outreach Entergy Nuclear Northeast provides customized outreach education programs for schools, youth groups, and civic organizations. The topics we cover include Emergency Planning, Understanding Radiation, Nuclear Fuel and a general overview of the operations of Indian Point Energy Center. If you would like a brochure or are interested in scheduling a program, contact IPEC Communications at 914-271-7441.

If you have any questions or need clarification of the information provided, please contact Kathy McMullin, manager of communications, Indian Point Energy Center, at 914-271-7132.