Dominion Resources Services, Inc.
i O 0 O Domin~on Boulevard, Glen Allen, VA 21060 August 4,2006 Mr. Stuart A. Richards, Deputy Director Division of Inspection and Regional Support Office of Nuclear Reactor Regulation U. S. Nuclear Regulatory Commission Washington, DC 20555-0001 p Dominion' Serial No.06-636 NLOS/TJS Rev 1 Docket Nos. 50-245,336,423 50-305 50-338,339 50-280, 281 License Nos. DPR-21,65, NPF-49 DPR-43 NPF-4, 7 DPR-32,37 DOMINION NUCLEAR CONNECTICUT, INC.
MILLSTONE POWER STATION UNITS 1,2, AND 3 DOMINION ENERGY KEWAUNEE, INC.
KEWAUNEE POWER STATION VIRGINIA ELECTRIC AND POWER COMPANY NORTH ANNA POWER STATION UNITS 1 AND 2 SURRY POWER STATION UNITS 1 AND 2 GROUNDWATER PROTECTION - DATA COLLECTION QUESTIONNAIRES The nuclear industry, in conjunction with the Nuclear Energy Institute, has developed a questionnaire to facilitate the collection of groundwater data at commercial nuclear reactor sites. The objective of the questionnaire is to compile baseline information about the current status of site programs for monitoring and protecting groundwater and to share that information with the NRC. The completed questionnaires for the Millstone, Kewaunee, North Anna, and Surry Power Stations are attached.
Should you have any questions regarding this submittal, please contact Mr. David A. Sommers at (804) 273-2823.
Very truly yours, Eugene S. Grecheck Vice President - Nuclear Support Services Dominion Nuclear Connecticut, Inc.
Dominion Energy Kewaunee, Inc.
Virginia Electric and Power Company Attachments: (4)
Commitments made by this letter: None
Serial No.06-636 Docket Nos. 50-245,336, 423, 305, 338, 339,280, 281 NEI GPI Questionnaire Responses Page 2 of 3 cc:
Document Control Desk U. S. Nuclear Regulatory Commission Washington, DC 20555-0001 U. S. Nuclear Regulatory Commission Region I 475 Allendale Road King of Prussia, Pennsylvania 19406-1 41 5 U. S. Nuclear Regulatory Commission Region II Sam Nunn Atlanta Federal Center 61 Forsyth Street, SW Suite 23T85 Atlanta, Georgia 30303 U. S. Nuclear Regulatory Commission Region Ill 2443 Warrenville Road Suite 21 0 Lisle, Illinois 60532-4352 Mr. S. M. Schneider NRC Senior Resident lnspector Millstone Power Station Mr. S. C. Burton NRC Senior Resident lnspector Kewaunee Power Station Mr. J. T. Reece NRC Senior Resident lnspector North Anna Power Station Mr. N. P. Garrett NRC Senior Resident lnspector Surry Power Station
Serial No.06-636 Docket Nos. 50-245, 336, 423, 305, 338, 339,280, 281 NEI GPI Questionnaire Responses Page 3 of 3 Mr. V. Nerses NRC Senior Project Manager - Millstone Power Station U. S. Nuclear Regulatory Commission One White Flint North 1 1 555 Rockville Pike Mail Stop 8C2 Rockville, Maryland 20852-2738 Mr. D. H. Jaffe NRC Project Manager - Kewaunee Power Station U. S. Nuclear Regulatory Commission One White Flint North 1 1 555 Rockville Pike Mail Stop 0-7-D-1 Rockville, Maryland 20852-2738 Mr. S. R. Monarque NRC Project Manager - North Anna Power Station U. S. Nuclear Regulatory Commission One White Flint North 1 1 555 Rockville Pike Mail Stop 8-HI 2 Rockville, Maryland 20852-2738 Mr. S. P. Lingam NRC Project Manager - Surry Power Station U. S. Nuclear Regulatory Commission One White Flint North 1 1 555 Rockville Pike Mail Stop 8 G9A Rockville, Maryland 20852-2738 Mr. R. Anderson Director - Health Physics and Low-Level Waste Nuclear Energy Institute Suite 400 1776 Eye Street, NW Washington, DC 20006 Serial No.06-636 Millstone Power Station NEI Groundwater protection Initiative Questionnaire Response Dominion Nuclear Connecticut, Inc.
Industry Groundwater Protection Initiative Voluntary Data Collection Questionnaire Plant: Millstone Power Station Briefly describe the program and/or methods used for detection of leakage or spills from plant systems, structures, and components that have a potential for an inadvertent release of radioactivity from plant operations into groundwater.
Millstone has several programs and methods used for detection of leakage or spills. These include:
A containment groundwater under-drains system for Unit 3 designed to collect water from under the containment. The groundwater collected from this system is routinely sampled and analyzed for radionuclides, including tritium.
Chemistry surveillances that include monthly sampling and analysis of storm water in the yard drains (catch basins).
Routine surveillances performed by Operations during rounds to monitor equipment integrity. It is also an expectation that Health Physics, Engineering and Chemistry personnel will monitor system or component leakage as part of their duties. Leaks or component degradation are reported via the corrective action system.
An inspection program for outdoor storage tanks (e.g., Refueling Water Storage Tanks) which requires an external inspection once per three (3) years and an internal inspection once per ten (10) years.
A corrective action system where significant occurrences of leakage or spills are documented.
Briefly describe the program and/or methods for monitoring onsite groundwater for the presence of radioactivity released from plant operations.
Millstone has 71 wells onsite, of which 30 are inside the Protected Area. These wells were originally installed for monitoring of potential chemical pollutants. The wells inside the Protected Area and those in the ground water flow path from the Protected Area, are also monitored for radioactivity.
There are two well water monitoring programs:
The Radiological Environmental Monitoring Program requires sampling and analysis of well water. This is described in the Millstone Radiological Effluent Monitoring and Offsite Dose Calculation Manual (REMODCM). Two selected well locations are rotated among several wells nearby potential sources of radiological contaminants (e.g., RWSTs, fuel pools, station stack sump). Required sampling is for gamma emitters and tritium. These wells are currently sampled quarterly and include analyses for Strontium 89 and 90. Required and typical detection levels are:
NUCLIDE REMP REQU~RED Tv~ical REMP MDA J~CiIliter)
Industry Groundwater Protection Initiative Voluntary Data Collection Questionnaire In support of previous projects, quarterly sampling for chemical pollutants was conducted for many of these wells. This sampling has been scaled back to 10 wells that were last sampled in June 2006. Two of these wells are located inside the Protected Area. Since the chemical analysis of these samples is normally performed offsite, the samples had to meet unconditional radioactive release ("free release")
standards. This required gamma and tritium analyses at the above listed lower limits of detection (LLDs).
In addition to the well water analyses, samples are taken monthly from catch basins and weekly from the Unit 3 containment under-drains. These samples are analyzed for tritium and gamma emitters. Catch basins that drain to the quarry are analyzed to effluent LLDs, while the catch basins that drain directly into the Long Island Sound are counted to environmental LLD's. The under-drains samples are also counted to environmental LLDs.
The required LLDs are:
NUCLIDE Effluent LLD*
(pcilliter)
Environmental LLD*
(pcilliter)
- Excluding H-3, typical detection limits are near these values for these samples
Industry Groundwater Protection Initiative Voluntary Data Collection Questionnaire
- 3. If applicable, briefly summarize any occurrences of inadvertent releases of radioactive liquids that had the potential to reach groundwater and have been documented in accordance with 10 CFR 50.75(g).
DNC maintains records of those instances where inadvertent release of radioactive liquids has occurred as required by 10 CFR 50.75(g). These records are available onsite at any time for NRC review. A review of those records identified 10 occurrences where either the volume or source of the release would have exceeded a reporting threshold defined for this voluntary initiative. These have been cleaned up to the extent that any remaining contamination has been judged to not represent a threat to the environment or to offsite and onsite personnel.
Further remediation as appropriate will occur when the site is decommissioned.
- 4. If applicable, briefly summarize the circumstances associated with any onsite or offsite groundwater monitoring result indicating a concentration in groundwater of radioactivity released from plant operations that exceeds the maximum contaminant level (MCL) established by the USEPA for drinking water.
There have been no instances of onsite or offsite groundwater monitoring which indicated a concentration exceeding the MCL established by the EPA.
- 5. Briefly describe any remediation efforts undertaken or planned to reduce or eliminate levels of radioactivity resulting from plant operations in soil or groundwater onsite or offsite.
Remediation of soil/gravel/asphalt has occurred in response to some of the spills/leaks as described in the response to item 3. Documentation of the occurrences in the 10 CFR 50.75(g) file will be used during decommissioning for final remediation of the spill areas.
Remediation considerations will be a component of the station's groundwater initiative action plan.
Serial No.06-636 Kewaunee Power Station NEI Groundwater protection Initiative Questionnaire Response Dominion Energy Kewaunee, Inc.
Industry Groundwater Protection Initiative Voluntary Data Collection Questionnaire Plant: Kewaunee Power Station
- 1. Briefly describe the program andlor methods used for detection of leakage or spills from plant systems, structures, and components that have a potential for an inadvertent release of radioactivity from plant operations into groundwater.
KPS has several programs 1 methods used for detection of leakage or spills. These include:
Operations personnel monitor for leakage during routine surveillances of their assigned area. Immediate actions include attempts to terminate and clean-up leakage.
As part of our Boron Leak Identification program, all personnel are expected to monitor borated systems for degradation.
A program to monitor accessible portions of storm drains for in-leakage, i.e., they are monitored for water during dry seasons when water would not be expected to be in them.
A program to monitor water systems that are not expected to be radioactive for radioactivity, i.e., steam generator blow-down, turbine building sump discharge, and potable water.
A corrective action program to document issues found as part of plant operation.
- 2. Briefly describe the program and/or methods for monitoring onsite groundwater for the presence of radioactivity released from plant operations.
Onsite groundwater monitoring is conducted as part of the Radiological Environmental Monitoring Manual. Each of these is described below.
Kewaunee samples two on-site wells. These wells provide the drinking water supply for the site. Sampling occurs quarterly, and analysis is for gamma isotopic, tritium, gross beta, gross alpha, and Sr 89/90.
Five (5) on-site surface water locations are also sampled monthly. These include two creeks just north and south of the plant, an additional creek further north, the condenser discharge and 500' north of the condenser discharge. These are all analyzed for gross beta, gamma isotopic, tritium and Sr 89/90.
The required Lower Limits of Detection (LLDs) and an example of typical Minimum Detectable Activities (MDA) are:
NUCLIDE REQUIRED LLD (pCi/L)
H-3 2000 Mn-54 15 Fe-59 30 CO-58, 60 15 Zn-65 30 Zr-95 15 MDA
( pCi/L)
-160
<15
<30
<15
<30
<I5
Industry Groundwater Protection Initiative Voluntary Data Collection Questionnaire N b-95 15
<I5 CS-1 34 15 c1 0 CS-1 37 18
<I 0 Ba-La-1 40 15 4 5 Sr-89 N/A c0.9 Sr-90 N/A
<0.6
- 3. If applicable, briefly summarize any occurrences of inadvertent releases of radioactive liquids that had the potential to reach groundwater and have been documented in accordance with 10 CFR 50.75(g).
Kewaunee has no documentation of occurrences of inadvertent releases of radioactive liquids where either the volume or source of the release would have exceeded a reporting threshold defined for this voluntary initiative. Kewaunee is currently reviewing records and performing interviews to ensure it has properly identified and classified all occurrences that might be considered in this initiative.
- 4. If applicable, briefly summarize the circumstances associated with any onsite or offsite groundwater monitoring result indicating a concentration in groundwater of radioactivity released from plant operations that exceeds the maximum contaminant level (MCL) established by the USEPA for drinking water.
Analysis of all the samples noted in response to question 2 above have been at or below the LLD values used by Kewaunee's Radiological Environmental Monitoring Program vendor.
- 5. Briefly describe any remediation efforts undertaken or planned to reduce or eliminate levels of radioactivity resulting from plant operations in soil or groundwater onsite or offsite.
Kewaunee has not identified a need to perform any remediation activities at this time.
Serial No.06-636 North Anna Power Station NEI Groundwater protection Initiative Questionnaire Response Virginia Electric and Power Company
Industry Groundwater Protection Initiative Voluntary Data Collection Questionnaire Plant: North Anna Power Station
- 1. Briefly describe the program andor methods used for detection of leakage or spills from plant systems, structures, and components that have a potential for an inadvertent release of radioactivity from plant operations into groundwater.
North Anna has several programs used for detection of leakage or spills. These include:
Operations personnel perform routine surveillance for leaks during rounds. It is also an expectation that Health Physics, Engineering and Chemistry personnel will monitor system or component leakage as part of their duties.
Leaks or component degradation are reported via the corrective action system.
As part of the Boric Acid Control Program all personnel are expected to monitor and report degradation of borated systems.
A program was established in response to Information Notice 91-40, "Contamination of Non-Radioactive System and Resulting Potential for an Unmonitored, Uncontrolled Release to the Environment." It is designed to monitor normally non-radioactive systems for radioactivity. It measures radioactivity to the effluent Lower Limits of Detection (LLD), as specified in the Offsite Dose Calculation Manual.
- 2. Briefly describe the program andor methods for monitoring onsite groundwater for the presence of radioactivity released from plant operations.
Onsite groundwater monitoring is conducted as part of:
The Radiological Environmental Monitoring Program, An agreement with Louisa County, Virginia, and A response to Information Notice 91-40.
The groundwater monitoring program is described below.
The groundwater well at Environmental Station OlA, located 0.64 miles Southeast of U-1 Containment is sampled quarterly and analyzed for tritium (H-3) and gamma emitters. It is analyzed annually for Sr-89 and Sr-90. Its location was selected to monitor infiltration of lake water into ground water. This is a non-drinking water well.
As part of an agreement with Louisa County, Virginia, two wells are sampled annually at the ISFSI. These samples are analyzed for H-3, gamma emitters, and Sr-891-90 to environmental LLD levels as specified in the Offsite Dose Calculation Manual. The required LLDs and an example of achieved Minimum Detectable Activities, (MDAs), for the wells at Station 01A and the ISFSI are:
Industry Groundwater Protection Initiative Voluntary Data Collection Questionnaire NUCLIDE REQUIRED MDA LLD (pCi/L) (SAMPLE L-5636)
(pCiIL)
H-3 2000
-1 200 Mn-54 15
-5 Fe-59 30
- 8 CO-58,60 15
-4 Zn-65 30
-1 3 Zr-95 30
- 6 N b-95 15
-5 CS-134 15
-5 CS-1 37 18
-4 Ba-1 40 60
-8 La-1 40 15
- 9 Sr-89 NIA
-8 Sr-90 N/A
-1.5 In addition to these, samples are taken quarterly from the storm drain out falls (3) and subsurface drains as part of implementation of Information Notice 91-40. These samples are analyzed for tritium and gamma emitters. Under this program, no radioactivity above MDA has been detected in the storm drain out falls or subsurface drains. The required LLDs and typical MDAs achieved are:
NUCLIDE H-3 Mn-54 Fe-59 CO-58 CO-60 Zn-65 Mo-99 1-1 31 Cs-1 34 CS-1 37 Ce-141 Ce-1 44 REQUIRED LLD (pCi1L) 10000 500 500 500 500 500 500 1000 500 500 500 500 MDA (pCiIL) 3000 10 20 15 15 25 100 20 10 20 50 300
- 3. If applicable, briefly summarize any occurrences of inadvertent releases of radioactive liquids that had the potential to reach groundwater and have been documented in accordance with 10 CFR 50.75(g).
North Anna maintains records of those instances where inadvertent release of radioactive liquids has occurred as required by 10 CFR 50.75(g). Those records are available onsite
Industry Groundwater Protection Initiative Voluntary Data Collection Questionnaire at any time for NRC review. A review of those records identified 56 occurrences where either the volume or source of the release would have exceeded a reporting threshold defined for this voluntary initiative. These occurrences have been cleaned up to the extent that any remaining contamination has been judged not to represent a threat to the environment or to offsite and onsite personnel. Further remediation as appropriate will occur when the site is decommissioned.
- 4. If applicable, briefly summarize the circumstances associated with any onsite or offsite groundwater monitoring result indicating a concentration in groundwater of radioactivity released from plant operations that exceeds the maximum contaminant level (MCL) established by the USEPA for drinking water.
There have been no instances of onsite or offsite groundwater monitoring which indicated a concentration exceeding the MCL established by the EPA.
- 5. Briefly describe any remediation efforts undertaken or planned to reduce or eliminate levels of radioactivity resulting from plant operations in soil or groundwater onsite or offsite.
Remediation of soiVgraveVasphalt has occurred in response to some of the spills/leaks reported in the response to item 3 above. Documentation of the occurrences in the 10 CFR 50.75(g) file will be used during decommissioning to remediate spill areas.
Remediation considerations will be a component of the station's groundwater initiative action plan.
Serial No.06-636 Surry Power Station NEI Groundwater protection Initiative Questionnaire Response Virginia Electric and Power Company
Industry Groundwater Protection Initiative Voluntary Data Collection Questionnaire Plant: Surry Power Station
- 1. Briefly describe the program and/or methods used for detection of leakage or spills from plant systems, structures, and components that have a potential for an inadvertent release of radioactivity from plant operations into groundwater.
Surry has several programs and methods used for detection of leakage or spills. These include:
A subsurface drainage system to prevent excessive hydrostatic pressure on plant structures. Water collected from this system is transferred to the storm drains system where it is sampled and analyzed for gamma emitters weekly and analyzed for tritium monthly in accordance with plant procedures.
Engineers perform periodic walkdowns of the systems for which they are responsible. These walkdowns include identification of steam, water and boric acid leakage from systems and components. Leakage is reported to Operations and entered into the corrective action system.
Operations personnel monitor for leakage during routine surveillances of their assigned area. Immediate actions include attempts to terminate and clean-up leakage. Leakage is reported and entered into the corrective action system.
Health Physics and Chemistry personnel perform plant walkdowns. It is part of their duties to monitor for leaks and spills. Leakage is reported to Operations and entered into the corrective action system.
ASME section XI testing includes reactor containment leak rate and integrity checks performed to identify and quantify leakage. Refueling water storage tanks (RWST) and selected underground piping associated with the RWST are also monitored.
- 2. Briefly describe the program and/or methods for monitoring onsite groundwater for the presence of radioactivity released from plant operations.
Onsite groundwater monitoring is conducted as part of the Radiological Environmental Monitoring Program (REMP). The onsite domestic water system that provides drinking water to the plant is sampled quarterly. Also, an offsite residential drinking water well is sampled quarterly as part of the REMP. The residential deep water well is located 1.9 miles NNE of Unit #1 containment.
These samples are analyzed for gamma emitters and tritium. The required Lower Limit of Detection (LLDs) and typical Minimum Detectable Activity (MDAs) for these samples are:
NUCLIDE LLD, pCi1L MDA, pCi/L H-3 2,000 1,300 Mn-54 15 5.1 Fe-59 30 10 CO-58 15 4.1 Co-60 15 4.9 Zn-65 30 11
Zr-95 30 6.9 Nb-95 15 5.2 1-131 1
0.6 CS-134 15 6.0 CS-137 18 4.1 Ba-140 60 7.8 La-140 15 9.0 Onsite water monitoring is also conducted as part of the Radiological Effluent Technical Specification program. Water from the subsurface drain and Turbine Building drain systems are released through the Storm Drain system. Storm drain out falls are sampled and analyzed weekly for gamma emitters and analyzed for tritium monthly. The required LLDs and typical MDAs for these samples are:
NUCLIDE H-3 Mn-54 Fe-59 CO-58 Co-60 Zn-65 MO-99 CS-134 CS-137 Ce-141 Ce-144 1-131 Sr-89 SS-90 Fe-55 LLD, pCi/L 10,000 500 500 500 500 500 500 500 500 500 500 1,000 50 50 1,000 MDA, pCi/L 1630 12 2 1 18 19 20 179 9
11 15 5 5 12 43 3 3 330
- 3. If applicable, briefly summarize any occurrences of inadvertent releases of radioactive liquids that had the potential to reach groundwater and have been documented in accordance with 10 CFR 50.75(g).
Surry maintains records of those instances where inadvertent release of radioactive liquids has occurred as required by 10 CFR 50.75(g). Those records are available onsite at any time for NRC review. A review of those records identified 8 occurrences where either the volume or source of the release would have exceeded a reporting threshold defined for this voluntary initiative. These occurrences have been cleaned up to the extent that any remaining contamination has been judged to not represent a threat to the environment or to offsite and onsite personnel. Further remediation as appropriate will occur when the site is decommissioned.
- 4. If applicable, briefly summarize the circumstances associated with any onsite or offsite groundwater monitoring result indicating a concentration in groundwater of radioactivity released from plant operations that exceeds the maximum contaminant level (MCL) by the USEPA for drinking water.
There have been no instances of onsite or offsite groundwater monitoring which indicated a concentration exceeding the MCL established by the EPA.
- 5. Briefly describe any remediation efforts undertaken or planned to reduce or eliminate levels of radioactivity resulting from plant operations in soil or groundwater onsite or offsite.
Remediation of soil/gravel/asphalt has occurred in response to some of the spills/leaks reported in the response to item 3 above. Documentation of the occurrences in the 10 CFR 50.75(g) file will be used during decommissioning to remediate spill areas. Remediation considerations will be a component of the station's groundwater initiative action plan.